WorldWideScience

Sample records for tissue slices vitrified

  1. Comparison of the developmental potential of 2-week-old preantral follicles derived from vitrified ovarian tissue slices, vitrified whole ovaries and vitrified/transplanted newborn mouse ovaries using the metal surface method

    Directory of Open Access Journals (Sweden)

    Hsu Kung-Hao

    2008-04-01

    comparing 14-day old ovarian tissue (ovarian tissue slices and whole ovaries and whole newborn ovaries vitrified in 6 μl droplet, lower success rates of antral-like cavity formation and COCs collection were found in the whole ovaries group. Conclusion Our results suggest that the metal plate surface vitrification method is an appropriate and convenient method for cryopreservation of mouse ovaries and preantral follicles. The droplet volume of vitrification solution in 2 μl and 6 μl can be an option.

  2. Cardiac tissue slices: preparation, handling, and successful optical mapping.

    Science.gov (United States)

    Wang, Ken; Lee, Peter; Mirams, Gary R; Sarathchandra, Padmini; Borg, Thomas K; Gavaghan, David J; Kohl, Peter; Bollensdorff, Christian

    2015-05-01

    Cardiac tissue slices are becoming increasingly popular as a model system for cardiac electrophysiology and pharmacology research and development. Here, we describe in detail the preparation, handling, and optical mapping of transmembrane potential and intracellular free calcium concentration transients (CaT) in ventricular tissue slices from guinea pigs and rabbits. Slices cut in the epicardium-tangential plane contained well-aligned in-slice myocardial cell strands ("fibers") in subepicardial and midmyocardial sections. Cut with a high-precision slow-advancing microtome at a thickness of 350 to 400 μm, tissue slices preserved essential action potential (AP) properties of the precutting Langendorff-perfused heart. We identified the need for a postcutting recovery period of 36 min (guinea pig) and 63 min (rabbit) to reach 97.5% of final steady-state values for AP duration (APD) (identified by exponential fitting). There was no significant difference between the postcutting recovery dynamics in slices obtained using 2,3-butanedione 2-monoxime or blebistatin as electromechanical uncouplers during the cutting process. A rapid increase in APD, seen after cutting, was caused by exposure to ice-cold solution during the slicing procedure, not by tissue injury, differences in uncouplers, or pH-buffers (bicarbonate; HEPES). To characterize intrinsic patterns of CaT, AP, and conduction, a combination of multipoint and field stimulation should be used to avoid misinterpretation based on source-sink effects. In summary, we describe in detail the preparation, mapping, and data analysis approaches for reproducible cardiac tissue slice-based investigations into AP and CaT dynamics. Copyright © 2015 the American Physiological Society.

  3. Comparison of vitrified and unvitrified Eocene woody tissues by TMAH thermochemolysis – implications for the early stages of the formation of vitrinite

    Directory of Open Access Journals (Sweden)

    Huggett William W

    2006-10-01

    Full Text Available Abstract Samples of vitrified and unvitrified Eocene woody plant tissues collected from the Fossil Forest site, Geodetic Hills, Axel Heiberg Island, have been characterized by TMAH thermochemolysis. All samples are gymnosperm-derived, are of very low maturity and all share the same post-depositional geologic history. Differences in the distributions of products observed from vitrified and unvitrified samples suggest that vitrification of woody tissue is associated with modification of the lignin C3 side chain, following loss of all or most of the carbohydrate present in the precursor woody tissues. The key driver of vitrification appears to be physical compression of the tissue following biological removal of cellulosic materials.

  4. Slices

    KAUST Repository

    McCrae, James

    2011-01-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours of intersection of planes with a 3D object, for creating shape abstractions, motivated by their popularity in art and engineering. We first perform a user study to show that humans do define consistent and similar planar section proxies for common objects. Interestingly, we observe a strong correlation between user-defined planes and geometric features of objects. Further we show that the problem of finding the minimum set of planes that capture a set of 3D geometric shape features is both NP-hard and not always the proxy a user would pick. Guided by the principles inferred from our user study, we present an algorithm that progressively selects planes to maximize feature coverage, which in turn influence the selection of subsequent planes. The algorithmic framework easily incorporates various shape features, while their relative importance values are computed and validated from the user study data. We use our algorithm to compute planar slices for various objects, validate their utility towards object abstraction using a second user study, and conclude showing the potential applications of the extracted planar slice shape proxies. © 2011 ACM.

  5. Assessment of immunotoxicity using precision-cut tissue slices

    Science.gov (United States)

    2013-01-01

    1. When the immune system encounters incoming infectious agents, this generally leads to immunity. The evoked immune response is usually robust, but can be severely perturbed by potentially harmful environmental agents such as chemicals, pharmaceuticals and allergens. 2. Immunosuppression, hypersensitivity and autoimmunity may occur due to changed immune activity. Evaluation of the immunotoxic potency of agents as part of risk assessment is currently established in vivo with animal models and in vitro with cell lines or primary cells. 3. Although in vivo testing is usually the most relevant situation for many agents, more and more in vitro models are being developed for assessment of immunotoxicity. In this context, hypersensitivity and immunosuppression are considered to be a primary focus for developing in vitro methods. Three-dimensional organotypic tissue models are also part of current research in immunotoxicology. 4. In recent years, there has been a revival of interest in organotypic tissue models. In the context of immunotoxicity testing, precision-cut lung slices in particular have been intensively studied. Therefore, this review is very much focused on pulmonary immunotoxicology. Respiratory hypersensitivity and inflammation are further highlighted aspects of this review. Immunotoxicity assessment currently is of limited use in other tissue models, which are therefore described only briefly within this review. PMID:23199366

  6. Cryopreservation of Precision-cut Tissue Slices for Application in Drug Metabolism Research

    NARCIS (Netherlands)

    Graaf, Inge Anne Maria de

    2002-01-01

    The research described in this thesis had two important aims. The first was to determine whether tissue slices could be used as an in vitro tool to predict the in vivo metabolism of new drugs. The second aim was to find a manner to store tissue slices for longer time periods by cryopreservation.

  7. Brain slice on a chip: opportunities and challenges of applying microfluidic technology to intact tissues.

    Science.gov (United States)

    Huang, Yu; Williams, Justin C; Johnson, Stephen M

    2012-06-21

    Isolated brain tissue, especially brain slices, are valuable experimental tools for studying neuronal function at the network, cellular, synaptic, and single channel levels. Neuroscientists have refined the methods for preserving brain slice viability and function and converged on principles that strongly resemble the approach taken by engineers in developing microfluidic devices. With respect to brain slices, microfluidic technology may 1) overcome the traditional limitations of conventional interface and submerged slice chambers and improve oxygen/nutrient penetration into slices, 2) provide better spatiotemporal control over solution flow/drug delivery to specific slice regions, and 3) permit successful integration with modern optical and electrophysiological techniques. In this review, we highlight the unique advantages of microfluidic devices for in vitro brain slice research, describe recent advances in the integration of microfluidic devices with optical and electrophysiological instrumentation, and discuss clinical applications of microfluidic technology as applied to brain slices and other non-neuronal tissues. We hope that this review will serve as an interdisciplinary guide for both neuroscientists studying brain tissue in vitro and engineers as they further develop microfluidic chamber technology for neuroscience research.

  8. Constructing a Computer Model of the Human Eye Based on Tissue Slice Images

    OpenAIRE

    Dai, Peishan; Wang, Boliang; Bao, Chunbo; Ju, Ying

    2010-01-01

    Computer simulation of the biomechanical and biological heat transfer in ophthalmology greatly relies on having a reliable computer model of the human eye. This paper proposes a novel method on the construction of a geometric model of the human eye based on tissue slice images. Slice images were obtained from an in vitro Chinese human eye through an embryo specimen processing methods. A level set algorithm was used to extract contour points of eye tissues while a principle component analysi...

  9. Tumor tissue slice cultures as a platform for analyzing tissue-penetration and biological activities of nanoparticles.

    Science.gov (United States)

    Merz, Lea; Höbel, Sabrina; Kallendrusch, Sonja; Ewe, Alexander; Bechmann, Ingo; Franke, Heike; Merz, Felicitas; Aigner, Achim

    2017-03-01

    The success of therapeutic nanoparticles depends, among others, on their ability to penetrate a tissue for actually reaching the target cells, and their efficient cellular uptake in the context of intact tissue and stroma. Various nanoparticle modifications have been implemented for altering physicochemical and biological properties. Their analysis, however, so far mainly relies on cell culture experiments which only poorly reflect the in vivo situation, or is based on in vivo experiments that are often complicated by whole-body pharmacokinetics and are rather tedious especially when analyzing larger nanoparticle sets. For the more precise analysis of nanoparticle properties at their desired site of action, efficient ex vivo systems closely mimicking in vivo tissue properties are needed. In this paper, we describe the setup of organotypic tumor tissue slice cultures for the analysis of tissue-penetrating properties and biological activities of nanoparticles. As a model system, we employ 350μm thick slice cultures from different tumor xenograft tissues, and analyze modified or non-modified polyethylenimine (PEI) complexes as well as their lipopolyplex derivatives for siRNA delivery. The described conditions for tissue slice preparation and culture ensure excellent tissue preservation for at least 14days, thus allowing for prolonged experimentation and analysis. When using fluorescently labeled siRNA for complex visualization, fluorescence microscopy of cryo-sectioned tissue slices reveals different degrees of nanoparticle tissue penetration, dependent on their surface charge. More importantly, the determination of siRNA-mediated knockdown efficacies of an endogenous target gene, the oncogenic survival factor Survivin, reveals the possibility to accurately assess biological nanoparticle activities in situ, i.e. in living cells in their original environment. Taken together, we establish tumor (xenograft) tissue slices for the accurate and facile ex vivo assessment of

  10. Difference in Uptake of Tetrodotoxin and Saxitoxins into Liver Tissue Slices among Pufferfish, Boxfish and Porcupinefish

    Directory of Open Access Journals (Sweden)

    Yuji Nagashima

    2018-01-01

    Full Text Available Although pufferfish of the family Tetraodontidae contain high levels of tetrodotoxin (TTX mainly in the liver, some species of pufferfish, boxfish of the family Ostraciidae, and porcupinefish of the family Diodontidae do not. To clarify the mechanisms, uptake of TTX and saxitoxins (STXs into liver tissue slices of pufferfish, boxfish and porcupinefish was examined. Liver tissue slices of the pufferfish (toxic species Takifugu rubripes and non-toxic species Lagocephalus spadiceus, L. cheesemanii and Sphoeroides pachygaster incubated with 50 µM TTX accumulated TTX (0.99–1.55 µg TTX/mg protein after 8 h, regardless of the toxicity of the species. In contrast, in liver tissue slices of boxfish (Ostracion immaculatus and porcupinefish (Diodon holocanthus, D. liturosus, D. hystrix and Chilomycterus reticulatus, TTX content did not increase with incubation time, and was about 0.1 µg TTX/mg protein. When liver tissue slices were incubated with 50 µM STXs for 8 h, the STXs content was <0.1 µg STXs/mg protein, irrespective of the fish species. These findings indicate that, like the toxic species of pufferfish T. rubripes, non-toxic species such as L. spadiceus, L. cheesemanii and S. pachygaster, potentially take up TTX into the liver, while non-toxic boxfish and porcupinefish do not take up either TTX or STXs.

  11. [Study of methods of decalcification for making united slices of tooth and affiliated periodontic tissues].

    Science.gov (United States)

    Wang, Yu; Mu, Ya-bing; Miao, Lei-ying; Sun, Hong-chen; Li, Cheng-ku

    2007-03-01

    To study the methods of decalcification for making united slices of tooth and affiliated periodontic tissues. Twenty-one samples containing dog molars and affiliated periodontic tissues were divided into seven mean groups. The pH value of solution, time of decalcification, weight and volume of samples, and content of decalcified calcium were detected. The slices were observed by HE, specific, and immunohistochemical stain. The velocity of decalcification increased with decrease of solution pH. The weight of samples lightened by 37.61%, the volume reduced by 25.97% on average, and calcium decalcified was 174.49 mg per gram humid samples. The EDTA decalcification was slowest, but it was best. Decalcification was fast in Plank-Rycho solution while the section was worst, and faster in the formyl solution containing aluminium chloride than in EDTA, and the section was better. The 50% formyl solution containing aluminium chloride is an ideal decalcifying solution.

  12. Morphological and chemical information in fresh and vitrified ovarian tissues revealed by X-ray Microscopy and Fluorescence: observational study

    Science.gov (United States)

    Pascolo, L.; Venturin, I.; Gianoncelli, A.; Salomé, M.; Altissimo, M.; Bedolla, D. E.; Giolo, E.; Martinelli, M.; Luppi, S.; Romano, F.; Zweyer, M.; Ricci, G.

    2018-06-01

    Many clinical circumstances impose the necessity of collection and prolonged storage of gametes and/or ovarian tissue in order to preserve the reproduction potential of subjects. This is particularly appropriate in the case of young women and pre-pubertal girls undergoing chemotherapeutic treatments. The success of later assisted fertilization will depend on the suitable cooling protocols minimizing cryo-damages and preserving their biological function. The freeze-thaw processes of cryopreservation may induce, in fact, morphological and structural damages of oocytes and tissue mainly due to the formation of intracellular ice and to the toxicity of cryoprotectant. The most used cryo-protocol is the slow freezing procedure, but recently many authors have proposed vitrification as an alternative, because of its simplicity. The damage extent and the quality of follicles after cryopreservation are usually evaluated morphologically by conventional histological procedures, light and electron microscopy. Our laboratory, to further improve the evaluation and to better investigate damages, is adopting a combination of Synchrotron soft X-ray Microscopy (at TwinMic – Elettra) and XRF at different incident energies (at TwinMic – Elettra and ID21 – ESRF). X-ray techniques were performed on histological sections at micro and sub-micron resolution. Phase contrast and absorption images revealed changes in the compactness of the tissues, as well as cellular abnormalities revealed at sub-micrometric resolution. The distributions of the elements detected at 7.3 and 1.5 keV were compared and particularly Cl resulted to be indicative of follicle integrity. The results demonstrate the utility and the potential of X-ray microscopy and fluorescence in this research field.

  13. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Mouse pancreas tissue slice culture facilitates long-term studies of exocrine and endocrine cell physiology in situ.

    Science.gov (United States)

    Marciniak, Anja; Selck, Claudia; Friedrich, Betty; Speier, Stephan

    2013-01-01

    Studies on pancreatic cell physiology rely on the investigation of exocrine and endocrine cells in vitro. Particularly, in the case of the exocrine tissue these studies have suffered from a reduced functional viability of acinar cells in culture. As a result not only investigations on dispersed acinar cells and isolated acini were limited in their potential, but also prolonged studies on pancreatic exocrine and endocrine cells in an intact pancreatic tissue environment were unfeasible. To overcome these limitations, we aimed to establish a pancreas tissue slice culture platform to allow long-term studies on exocrine and endocrine cells in the intact pancreatic environment. Mouse pancreas tissue slice morphology was assessed to determine optimal long-term culture settings for intact pancreatic tissue. Utilizing optimized culture conditions, cell specificity and function of exocrine acinar cells and endocrine beta cells were characterized over a culture period of 7 days. We found pancreas tissue slices cultured under optimized conditions to have intact tissue specific morphology for the entire culture period. Amylase positive intact acini were present at all time points of culture and acinar cells displayed a typical strong cell polarity. Amylase release from pancreas tissue slices decreased during culture, but maintained the characteristic bell-shaped dose-response curve to increasing caerulein concentrations and a ca. 4-fold maximal over basal release. Additionally, endocrine beta cell viability and function was well preserved until the end of the observation period. Our results show that the tissue slice culture platform provides unprecedented maintenance of pancreatic tissue specific morphology and function over a culture period for at least 4 days and in part even up to 1 week. This analytical advancement now allows mid -to long-term studies on the cell biology of pancreatic disorder pathogenesis and therapy in an intact surrounding in situ.

  15. Mouse pancreas tissue slice culture facilitates long-term studies of exocrine and endocrine cell physiology in situ.

    Directory of Open Access Journals (Sweden)

    Anja Marciniak

    Full Text Available Studies on pancreatic cell physiology rely on the investigation of exocrine and endocrine cells in vitro. Particularly, in the case of the exocrine tissue these studies have suffered from a reduced functional viability of acinar cells in culture. As a result not only investigations on dispersed acinar cells and isolated acini were limited in their potential, but also prolonged studies on pancreatic exocrine and endocrine cells in an intact pancreatic tissue environment were unfeasible. To overcome these limitations, we aimed to establish a pancreas tissue slice culture platform to allow long-term studies on exocrine and endocrine cells in the intact pancreatic environment. Mouse pancreas tissue slice morphology was assessed to determine optimal long-term culture settings for intact pancreatic tissue. Utilizing optimized culture conditions, cell specificity and function of exocrine acinar cells and endocrine beta cells were characterized over a culture period of 7 days. We found pancreas tissue slices cultured under optimized conditions to have intact tissue specific morphology for the entire culture period. Amylase positive intact acini were present at all time points of culture and acinar cells displayed a typical strong cell polarity. Amylase release from pancreas tissue slices decreased during culture, but maintained the characteristic bell-shaped dose-response curve to increasing caerulein concentrations and a ca. 4-fold maximal over basal release. Additionally, endocrine beta cell viability and function was well preserved until the end of the observation period. Our results show that the tissue slice culture platform provides unprecedented maintenance of pancreatic tissue specific morphology and function over a culture period for at least 4 days and in part even up to 1 week. This analytical advancement now allows mid -to long-term studies on the cell biology of pancreatic disorder pathogenesis and therapy in an intact surrounding in situ.

  16. Evaluation of apoptotic- and autophagic-related protein expressions before and after IVM of fresh, slow-frozen and vitrified pre-pubertal mouse testicular tissue.

    Science.gov (United States)

    Dumont, L; Chalmel, F; Oblette, A; Berby, B; Rives, A; Duchesne, V; Rondanino, C; Rives, N

    2017-11-01

    Do freezing and in vitro culture procedures enhance the expression of proteins involved in apoptotic or autophagic pathways in murine pre-pubertal testicular tissue? IVM strongly modified apoptosis- and autophagy-related relative protein levels in mice testicular tissue whereas the impact of cryopreservation procedures was minimal at the end of the culture. In vitro spermatogenesis remains a challenging technical issue as it imposes to find a very close balance between survival and death of germ cell natural precursors (i.e. gonocytes and spermatogonia), which will eventually undergo a complete spermatogenesis close to in vivo conditions. The establishment of efficient culture conditions coupled with suitable cryopreservation procedures (e.g. controlled slow freezing [CSF] and solid surface vitrification [SSV]) of pre-pubertal testicular tissue is a crucial step in the fields of fertility preservation and restoration to improve the spermatic yield obtained in vitro. Here, we study cryopreservation procedures (i.e. CSF or SSV) and the impact of culture media compositions. A first set of 66 mouse pre-pubertal testes were directly cultured during 30, 36, 38 and 60 days (D) from 2.5 to 6.5-day-old CD-1 mice to evaluate the impact of time-aspect of culture and to endorse the reverse phase protein microarrays (RPPM) technique as an adapted experimental tool for the field of in vitro spermatogenesis. Ninety others fresh, slow-frozen and vitrified pre-pubertal testes were cultured during 30 days for the principal study to evaluate the impact of cryopreservation procedures before and after culture. Thirty-four testes dissected from 2.5, 6.5, 36.5, 40.5, 42.5 and 62.5 days postpartum (dpp) mice, corresponding to the time frames of spermatogenesis orchestrated in vitro, were used as in vivo controls. After in vitro culture, testicular tissue samples originated from 2.5 or 6.5-day-old CD-1 male mice were analyzed using RPPM. This targeted proteomic technique allowed us to

  17. Examination of the structure-toxicity relationships of L-cysteine-S-conjugates of halogenated alkenes and their corresponding mercapturic acids in rat renal tissue slices.

    NARCIS (Netherlands)

    Stijntjes, G.J.; Commandeur, J.N.M.; te Koppele, J.M.; McGuinness, S; Gandolfi, A.J.; Vermeulen, N.P.E.

    1993-01-01

    Rat kidney slices were produced using a modified version of a mechanical tissue slicer. The slices were incubated with various concentrations of l-cysteine conjugates and mercapturic acids of halogenated alkenes in a submersion incubation system. The slices showed a time- and concentration-dependent

  18. Error analysis of the microradiographical determination of mineral content in mineralised tissue slices

    International Nuclear Information System (INIS)

    Jong, E. de J. de; Bosch, J.J. ten

    1985-01-01

    The microradiographic method, used to measure the mineral content in slices of mineralised tissues as a function of position, is analysed. The total error in the measured mineral content is split into systematic errors per microradiogram and random noise errors. These errors are measured quantitatively. Predominant contributions to systematic errors appear to be x-ray beam inhomogeneity, the determination of the step wedge thickness and stray light in the densitometer microscope, while noise errors are under the influence of the choice of film, the value of the optical film transmission of the microradiographic image and the area of the densitometer window. Optimisation criteria are given. The authors used these criteria, together with the requirement that the method be fast and easy to build an optimised microradiographic system. (author)

  19. Glucose-stimulated calcium dynamics in islets of Langerhans in acute mouse pancreas tissue slices.

    Directory of Open Access Journals (Sweden)

    Andraž Stožer

    Full Text Available In endocrine cells within islets of Langerhans calcium ions couple cell stimulation to hormone secretion. Since the advent of modern fluorimetry, numerous in vitro studies employing primarily isolated mouse islets have investigated the effects of various secretagogues on cytoplasmic calcium, predominantly in insulin-secreting beta cells. Due to technical limitations, insights of these studies are inherently limited to a rather small subpopulation of outermost cells. The results also seem to depend on various factors, like culture conditions and duration, and are not always easily reconcilable with findings in vivo. The main controversies regard the types of calcium oscillations, presence of calcium waves, and the level of synchronized activity. Here, we set out to combine the in situ acute mouse pancreas tissue slice preparation with noninvasive fluorescent calcium labeling and subsequent confocal laser scanning microscopy to shed new light on the existing controversies utilizing an innovative approach enabling the characterization of responses in many cells from all layers of islets. Our experiments reproducibly showed stable fast calcium oscillations on a sustained plateau rather than slow oscillations as the predominant type of response in acute tissue slices, and that calcium waves are the mechanistic substrate for synchronization of oscillations. We also found indirect evidence that even a large amplitude calcium signal was not sufficient and that metabolic activation was necessary to ensure cell synchronization upon stimulation with glucose. Our novel method helped resolve existing controversies and showed the potential to help answer important physiological questions, making it one of the methods of choice for the foreseeable future.

  20. Liver slices in in vitro pharmacotoxicology with special reference to the use of human liver tissue

    NARCIS (Netherlands)

    Olinga, Peter; Meijer, D.K F; Slooff, M.JH; Groothuis, Geny

    In the early years of research in in vitro pharmacotoxicology liver slices have been used. After a decline in the application of slices in favour of the use of isolated hepatocytes and the isolated perfused liver preparation, the development of the Krumdieck slicer in the 1980s led to a 'comeback'

  1. The role of glutamine transport in metabolism in the brain cortical tissue slice

    International Nuclear Information System (INIS)

    Hare, N.; Bubb, W.A.; Rae, C.; Broeer, S.

    2001-01-01

    The widely accepted 'glutamate/glutamine cycle' holds that glutamate released as a neurotransmitter in the brain is taken up by surrounding astrocytes, converted to neuro-inactive glutamine and transported back to neurons for reconversion to glutamate. Little, however, is known about the role of glutamine transport in this process. The situation is complicated by the fact that glutamine is transported by a variety of general amino-acid transporters of low specificity. The role of these transporters in flux of glutamine through the glutamate/glutamine cycle was investigated by 13 C NMR monitoring of the flux of C from [3- 13 C]L-lactate in guinea pig cortical tissue slices in the presence of competitive inhibitors of the A-type(α-(methylamino)isobutyrate; MeAIB) and N-type (histidine) transporters. The presence of each inhibitor (10 mM) produced no significant decrease in total metabolite pool size but resulted in a significant decrease in flux of [ 13 C] into the neurotransmitters glutamate and GABA and also into glutamine and alanine. The factional enrichment of glutamate and GABA was also significantly lower. By contrast there was no effect on the amount of [ 13 C] incorporated into aspartate isotopomers which may represent a predominantly astrocyte-labelled pool. These results are consistent with involvement of glutamine transporters in the recycling of synaptic glutamate by demonstrating partial blockage of incorporation of [ 13 C] label into neuronal metabolites

  2. Effects of intratracheal instillation of bleomycin on phospholipid synthesis in hamster lung tissue slices

    International Nuclear Information System (INIS)

    Giri, S.N.

    1987-01-01

    Bleomycin, an antineoplastic drug, is known to produce interstitial pulmonary fibrosis (IPF). As a result, it is commonly employed in various species to produce animal models of fibrosis. We have examined the uptake of [ 14 C] acetate by lung slices and its incorporation into lipids in the slices at various times following intratracheal administration of a fibrogenic dose of bleomycin in hamsters. As compared to saline controls, bleomycin had no effect on [ 14 C] acetate uptake at 4 and 7 days but it increased the uptake at 2 and 14 days after treatment. The incorporation of [ 14 C] acetate into total lipid was significantly reduced to 44, 62, 62, and 75% of the control at 2, 4, 7, and 14 days after bleomycin treatment, respectively. The incorporation into lipid as a percentage of the uptake was 12.2 in control animals whereas in bleomycin-treated animals, it was 4.7, 8.0, 7.3, and 6.9 at the corresponding times. Separation of lipids into various fractions revealed that bleomycin treatment specifically inhibited the synthesis of phosphatidylcholine and neutral lipid at all times of the study. The synthesis of all other phospholipids except phosphatidylethanolamine was depressed at 2 days. The latter was, however, depressed at 7 and 14 days after bleomycin treatment. It was concluded from the present study that bleomycin treatment inhibits the synthesis of phospholipid and neutral lipid and this may eventually lead to decreased surfactant production

  3. Cells in human postmortem brain tissue slices remain alive for several weeks in culture

    NARCIS (Netherlands)

    Verwer, Ronald W. H.; Hermens, Wim T. J. M. C.; Dijkhuizen, PaulaA; ter Brake, Olivier; Baker, Robert E.; Salehi, Ahmad; Sluiter, Arja A.; Kok, Marloes J. M.; Muller, Linda J.; Verhaagen, Joost; Swaab, Dick F.

    2002-01-01

    Animal models for human neurological and psychiatric diseases only partially mimic the underlying pathogenic processes. Therefore, we investigated the potential use of cultured postmortem brain tissue from adult neurological patients and controls. The present study shows that human brain tissue

  4. The rate of incorporation and degradation of phenylalanine-14C by tissue slices of roosters fed a phenylalanine-free diet

    International Nuclear Information System (INIS)

    Ishibashi, Teru; Kametaka, Masao

    1975-01-01

    To investigate the reason why adult roosters maintain nitrogen equilibrium on a phenylalanine-free diet for long periods, the rates of incorporation and of degradation of phenylalanine, tyrosine- and isoleucine- 14 C by tissue slices of roosters on the control, phenylalanine-free or isoleucine-free diets were measured. The degradation rate of isoleucine by liver and muscle slices decreased significantly for the isoleucine-free diet. However, the degradation rate of phenylalanine- 14 C by liver slices for the phenylalanine-free diet was not significantly lower than that for the control diet in contrast to the previous observation in vivo. The incorporation rates of 14 C into liver and muscle proteins were not affected by the dietary conditions in this experiment except in the case of phenylalanine- 14 C by muscle slices for the phenylalanine-free diet. (auth.)

  5. Development of vitrified waste storage system

    International Nuclear Information System (INIS)

    Namiki, S.; Tani, Y.

    1993-01-01

    The authors have developed the radioactive waste vitrification technology and the vitrified waste storage technology. Regarding the vitrified waste storage system development, the authors have completed the design of two types of storage systems. One is a forced convection air cooling system, and the other is a natural convection air cooling system. They have carried out experiments and heat transfer analysis, seismic analysis, vitrified waste dropping and radiation shielding, etc. In this paper, the following three subjects, are discussed: the cooling air flow experiment, the wind effect experiment on the cooling air flow pattern, using a wind tunnel apparatus and the structural integrity evaluation on the dropping vitrified waste

  6. Altered Loyalties of Neuronal Markers in Cultured Slices of Resected Human Brain Tissue

    NARCIS (Netherlands)

    Verwer, Ronald W. H.; Sluiter, Arja A.; Balesar, Rawien A.; Baayen, Johannes C.; Speijer, Dave; Idema, Sander; Swaab, Dick F.

    2016-01-01

    Organotypic cultures from normal neocortical tissue obtained at epilepsy surgery show a severe injury response. This response involves both neuronal degeneration and the proliferation of reactive cells. A salient feature of the reactive cells is the co-expression of microglial and astrocytic

  7. Cavitation Induced Structural and Neural Damage in Live Brain Tissue Slices: Relevance to TBI

    Science.gov (United States)

    2014-09-29

    objective of this project is to determine the conditions conducive for cavitation in cerebrospinal fluid (CSF) and corresponding tissue injury in 2-D brain...the radius of an isolated spherical bubble in an infinite, incompressible liquid is given by Where, R is the instantaneous bubble radius, which can...by the pressure transducer placed in the test chamber, and PR is the pressure in the liquid at the boundary of the bubble. The measurable bubble

  8. Vitrified waste option study report

    International Nuclear Information System (INIS)

    Lopez, D.A.; Kimmitt, R.R.

    1998-02-01

    A open-quotes Settlement Agreementclose quotes between the Department of Energy and the State of Idaho mandates that all radioactive high-level waste (HLW) now stored at the Idaho Chemical Processing Plant (ICPP) will be treated so that it is ready to be moved out of Idaho for disposal by a target date of 2035. This report investigates vitrification treatment of all ICPP calcine, including the existing and future HLW calcine resulting from calcining liquid Sodium-Bearing Waste (SBW). Currently, the SBW is stored in the tank farm at the ICPP. Vitrification of these wastes is an acceptable treatment method for complying with the Settlement Agreement. This method involves vitrifying the calcined waste and casting the vitrified mass into stainless steel canisters that will be ready to be moved out of the Idaho for disposal by 2035. These canisters will be stored at the Idaho National Engineering and Environmental Laboratory (INEEL) until they are sent to a HLW national repository. The operating period for vitrification treatment will be from 2013 through 2032; all HLW will be treated and in storage by the end of 2032

  9. Vitrified waste option study report

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, D.A.; Kimmitt, R.R.

    1998-02-01

    A {open_quotes}Settlement Agreement{close_quotes} between the Department of Energy and the State of Idaho mandates that all radioactive high-level waste (HLW) now stored at the Idaho Chemical Processing Plant (ICPP) will be treated so that it is ready to be moved out of Idaho for disposal by a target date of 2035. This report investigates vitrification treatment of all ICPP calcine, including the existing and future HLW calcine resulting from calcining liquid Sodium-Bearing Waste (SBW). Currently, the SBW is stored in the tank farm at the ICPP. Vitrification of these wastes is an acceptable treatment method for complying with the Settlement Agreement. This method involves vitrifying the calcined waste and casting the vitrified mass into stainless steel canisters that will be ready to be moved out of the Idaho for disposal by 2035. These canisters will be stored at the Idaho National Engineering and Environmental Laboratory (INEEL) until they are sent to a HLW national repository. The operating period for vitrification treatment will be from 2013 through 2032; all HLW will be treated and in storage by the end of 2032.

  10. Microfluidic culture chamber for the long-term perfusion and precise chemical stimulation of organotypic brain tissue slices

    DEFF Research Database (Denmark)

    Caicedo, H. H.; Vignes, M.; Brugg, B.

    2010-01-01

    We have developed a microfluidic perfusion-based culture system to study long-term in-vitro responses of organo-typic brain slices exposed to localized neurochemical stimulation. Using this microperfusion chamber we show that hip-pocampal organotypic brain slices cultures grown on nitrocellulose ...

  11. Compatibility testing of vitrified waste forms

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1978-01-01

    The compatibility of vitrified radioactive waste with candidate canister materials will be evaluated with both cast and in-can melted vitrified waste. Both real and simulated sludges will be used. In addition, the compatibility of these materials with salt from a possible final storage location will be determined. Cast vitrified waste will be tested with ASTM A 333 and ASTM A 516 low-carbon steels and Type 304L stainless steel at 100, 600 and 800 0 C. Cast vitrified waste that has been devitrified by heat treatment will be tested at 100 0 C. Two types of test specimens will be used with either simulated or real sludges: (1) unsealed capsules made of pieces of mill-finished pipe into which vitrified waste is cast, and (2) sealed capsules containing a small container of vitrified waste identical to the ones in the unsealed capsule. In-can melted vitrified waste will be tested with synthetic sludge only and with ASTM A 333 and ASTM A 516 low-carbon steels, Type 304L stainless steel and Inconel 600. Two types of tests will be carried out: (1) melting vitrified waste in miniature metal canisters and (2) exposure of small (carefully measured) metal coupons to molten glass. The air oxidation rates of candidate canister materials will be determined, and specimens will also be exposed to salt from Drill Hole AEC-8 in Carlsbad, New Mexico. Sealed capsules containing an ASTM A 516 low-carbon steel or Type 304L stainless steel specimen partially embedded in a small block of salt will be heated

  12. Architectural slicing

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2013-01-01

    Architectural prototyping is a widely used practice, con- cerned with taking architectural decisions through experiments with light- weight implementations. However, many architectural decisions are only taken when systems are already (partially) implemented. This is prob- lematic in the context...... of architectural prototyping since experiments with full systems are complex and expensive and thus architectural learn- ing is hindered. In this paper, we propose a novel technique for harvest- ing architectural prototypes from existing systems, \\architectural slic- ing", based on dynamic program slicing. Given...... a system and a slicing criterion, architectural slicing produces an architectural prototype that contain the elements in the architecture that are dependent on the ele- ments in the slicing criterion. Furthermore, we present an initial design and implementation of an architectural slicer for Java....

  13. 针对组织工程多孔生物陶瓷的组织学技术优化探讨%Technique improvement of hard tissue slicing of bioceramic scaffold materials applied in bone tissue engineering

    Institute of Scientific and Technical Information of China (English)

    李林; 智伟; 桑力; 张成栋; 李金雨; 张聪; 娄延举; 夏天; 翁杰

    2013-01-01

    目的 改进硬组织切片技术以适应生物陶瓷材料在骨组织工程中的研究.方法 探索硬组织切片的厚度、漂片温度、裱片方法、烤片温度和时间的最佳组合,针对阳离子防脱载玻片的使用条件进行反复比较,通过改进操作流程中的关键技术和需避免的问题,摸索出阳离子载玻片在硬组织切片裱片中的最佳应用条件,克服了硬组织切片制作技术中标本易破碎、切片易脱落及染色时染料容易吸附的缺点.结果 通过技术探索与改进,生物陶瓷支架材料体内植入后的类骨修复体标本的硬组织切片能保持其杂化后的组织结构与比较完整的材料结构,可进行Masson三色染色、苏木精-伊红(HE)及甲苯胺蓝染色.染色后镜下观察显示支架内杂化生长的组织结构完整、细胞形态清晰、切片质量好、生物陶瓷支架脱片少.荧光显微镜可观察到类骨修复体钙沉积现象完整.结论 改善了传统硬组织切片技术处理生物陶瓷材料时易于破坏组织-材料结构的缺点.改进的硬组织切片技术适应生物陶瓷材料在骨组织工程领域研究.%Objective Purpose To improve the hard tissue slicing technology to adapt to the study of the bioceramic materials in bone tissue engineering.Methods Purpose To improve the hard tissue slicing technology to adapt to the study of the bioceramic materials in bone tissue engineering.Results The improved techniques in hard tissue slicing could keep the morphosis and structure of hybrid tissues,and easily stain with Masson,HE and toluidine blue.The stained hard tissue slicing had an intact tissue structure,clear cell form,good slicing quality,little shedding.Fluorescence microscope showed an intact calcium deposition of homologous bone restoration.Conclusion The method overcome the shortcomings of easy to destroy the tissue-material structure happened in the traditional hard tissue slicing of bioceramic materials

  14. DOE regulatory reform initiative vitrified mixed waste

    International Nuclear Information System (INIS)

    Carroll, S.J.; Holtzscheiter, E.W.

    1997-01-01

    The US Department of Energy (DOE) is charged with responsibly managing the largest volume of mixed waste in the United States. This responsibility includes managing waste in compliance with all applicable Federal and State laws and regulations, and in a cost-effective, environmentally responsible manner. Managing certain treated mixed wastes in Resource Conservation and Recovery Act (RCRA) permitted storage and disposal units (specifically those mixed wastes that pose low risks from the hazardous component) is unlikely to provide additional protection to human health and the environment beyond that afforded by managing these wastes in storage and disposal units subject to requirements for radiological control. In October, 1995, the DOE submitted a regulatory reform proposal to the Environmental Protection Agency (EPA) relating to vitrified mixed waste forms. The technical proposal supports a regulatory strategy that would allow vitrified mixed waste forms treated through a permit or other environmental compliance mechanism to be granted an exemption from RCRA hazardous waste regulation, after treatment, based upon the inherent destruction and immobilization capabilities of vitrification technology. The vitrified waste form will meet, or exceed the performance criteria of the Environmental Assessment (EA) glass that has been accepted as an international standard for immobilizing radioactive waste components and the LDR treatment standards for inorganics and metals for controlling hazardous constituents. The proposal further provides that vitrified mixed waste would be responsibly managed under the Atomic Energy Act (AEA) while reducing overall costs. Full regulatory authority by the EPA or a State would be maintained until an acceptable vitrified mixed waste form, protective of human health and the environment, is produced

  15. The leaching characteristics of vitrified slag

    International Nuclear Information System (INIS)

    Zhang, Jinlong; Li, Yaojian; Tian, Junguo; Sheng, Hongzhi; Xu, Yongxiang

    2010-01-01

    Full Text: Plasma-arc technology was developed to fix the heavy metal of flying ash by the Institute of Mechanics, Chinese Academy of Sciences (CAS-IMECH). A direct current (DC) experimental facility of 30 kW with plasma-arc technology was setup to form vitrified slag. The additives (CaO, SiO 2 ) were added into the reactor to form vitrified slag and fix the heavy metal (Cr, Pb), under dissimilar condition (long and short heating-up time, natural and water cooling). Vitrified slag was broken into different particle size, from 0.1 mm to 1 cm. The particles with different specific surface area were used to study the leaching of heavy metals in vitrified slag rate of speed. The pH value of leaching solution are from 2 to 12, the experiment was kept at different external temperature, from 4 degree Celsius to 70 degree celsius, for 1 week to 1 month. Heavy metal leaching concentration was used to measure the chemical stability of vitrified slag. The results show that the higher specific surface area, the higher heavy metal leaching concentration, but when the specific surface area reaches a certain value, little change in leaching concentration. The impact of temperature on leaching concentration was not significant, from 4 degree Celsius to 70 degree Celsius. The leaching concentration increases with decreasing of the pH value of leaching solution when the pH value of leaching solution less than 7, and little change in concentration increases with pH value when the pH value of leaching solution more than 7. Compared with the leaching concentration after 1 month, the leaching concentration after 1 week has not changed significantly. (Author)

  16. Higher transport and metabolism of glucose in astrocytes compared with neurons: a multiphoton study of hippocampal and cerebellar tissue slices.

    Science.gov (United States)

    Jakoby, Patrick; Schmidt, Elke; Ruminot, Iván; Gutiérrez, Robin; Barros, L Felipe; Deitmer, Joachim W

    2014-01-01

    Glucose is the most important energy substrate for the brain, and its cellular distribution is a subject of great current interest. We have employed fluorescent glucose probes, the 2-deoxy-D-glucose derivates 6- and 2-([N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl) amino]-2-deoxy-D-glucose) (2-NBDG), to measure transport and metabolism of glucose in acute slices of mouse hippocampus and cerebellum. In the hippocampus, 6-NBDG, which is not metabolized and hence indicates glucose transport, was taken up faster in astrocyte-rich layers (Stratum radiatum [S.r.], Stratum oriens [S.o.]) than in pyramidal cells. Metabolizable 2-NBDG showed larger signals in S.r. and S.o. than in Stratum pyramidale, suggesting faster glucose utilization rate in the astrocyte versus the neuronal compartment. Similarly, we found higher uptake and temperature-sensitive metabolism of 2-NBDG in Bergmann glia when compared with adjacent Purkinje neurons of cerebellar slices. A comparison between 6-NBDG transport and glucose transport in cultured cells using a fluorescence resonance energy transfer nanosensor showed that relative to glucose, 6-NBDG is transported better by neurons than by astrocytes. These results indicate that the preferential transport and metabolism of glucose by glial cells versus neurons proposed for the hippocampus and cerebellum by ourselves (in vitro) and for the barrel cortex by Chuquet et al. (in vivo) is more pronounced than anticipated.

  17. Blood cell oxidative stress precedes hemolysis in whole blood-liver slice co-cultures of rat, dog, and human tissues

    International Nuclear Information System (INIS)

    Vickers, Alison E.M.; Sinclair, John R.; Fisher, Robyn L.; Morris, Stephen R.; Way, William

    2010-01-01

    A novel in vitro model to investigate time-dependent and concentration-dependent responses in blood cells and hemolytic events is studied for rat, dog, and human tissues. Whole blood is co-cultured with a precision-cut liver slice. Methimazole (MMI) was selected as a reference compound, since metabolism of its imidazole thione moiety is linked with hematologic disorders and hepatotoxicity. An oxidative stress response occurred in all three species, marked by a decline in blood GSH levels by 24 h that progressed, and preceded hemolysis, which occurred at high MMI concentrations in the presence of a liver slice with rat (≥ 1000 μM at 48 h) and human tissues (≥ 1000 μM at 48 h, ≥ 750 μM at 72 h) but not dog. Human blood-only cultures exhibited a decline of GSH levels but minimal to no hemolysis. The up-regulation of liver genes for heme degradation (Hmox1 and Prdx1), iron cellular transport (Slc40a1), and GSH synthesis and utilization (mGST1 and Gclc) were early markers of the oxidative stress response. The up-regulation of the Kupffer cell lectin Lgals3 gene expression indicated a response to damaged red blood cells, and Hp (haptoglobin) up-regulation is indicative of increased hemoglobin uptake. Up-regulation of liver IL-6 and IL-8 gene expression suggested an activation of an inflammatory response by liver endothelial cells. In summary, MMI exposure led to an oxidative stress response in blood cells, and an up-regulation of liver genes involved with oxidative stress and heme homeostasis, which was clearly separate and preceded frank hemolysis.

  18. Mouse Pancreas Tissue Slice Culture Facilitates Long-Term Studies of Exocrine and Endocrine Cell Physiology in situ

    OpenAIRE

    Marciniak, Anja; Selck, Claudia; Friedrich, Betty; Speier, Stephan

    2013-01-01

    Studies on pancreatic cell physiology rely on the investigation of exocrine and endocrine cells in vitro. Particularly, in the case of the exocrine tissue these studies have suffered from a reduced functional viability of acinar cells in culture. As a result not only investigations on dispersed acinar cells and isolated acini were limited in their potential, but also prolonged studies on pancreatic exocrine and endocrine cells in an intact pancreatic tissue environment were unfeasible. To ove...

  19. Return of vitrified wastes from France to Japan; Retour des residus vitrifies de France au Japon

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The radioactive wastes resulting from the burnup of nuclear fuels in nuclear reactors represent 3 to 5% of the spent fuel. These wastes cannot be reused nor recycled and thus are vitrified after reprocessing. Japanese power companies have signed contracts with Cogema in France and BNFL in the UK for the reprocessing of their spent fuels. Then, the ultimate reprocessed wastes are sent back to Japan for storage. This information dossier takes stock of different questions relative to the transport of the vitrified wastes from France to Japan: why France sends back containers of vitrified wastes to Japan? What is a vitrified wastes container made of? How containers are transported? What is the regulatory frame applicable to these transports? Which safety measures are taken during transport? Which physical protection is applied? Which temporary storage facilities are used before and after transportation? How is performed the ultimate storage of wastes in Japan? Which quality and safety warranties are taken? Which emergency plans and exercises are provided? What are the applicable civil liability regimes? And what kind of information is given to the public about these transports. Some general information about energy and nuclear power worldwide, energy and environment, radioactivity, BNFL, Cogema and ORC is given in appendixes. (J.S.)

  20. Source term measurements on vitrified HLW

    International Nuclear Information System (INIS)

    Hough, A.; Marples, J.A.C.

    1988-01-01

    The equilibrium concentrations of Tc-99, Np-237, Pu-239/240 and Am-241 have been measured in the presence of materials likely to be present in a vitrified HLW repository: glass, iron, backfill and rock. Results were measured under both oxidising and reducing conditions and at pH values set by the backfill bentonite and cement. Under reducing conditions and with cementitious backfills, the equilibrium concentrations ranged from three to 30 times allowed drinking water levels for the four isotopes. (author)

  1. Effect of dietary fat on uptake of lysine, phenylalanine, leucine and methionine by bovine mammary tissue slices in vitro

    International Nuclear Information System (INIS)

    Nianogo, A.J.; Amos, H.E.; Dean, R.; Froetschel, A.; Fernandez, J.M.

    1989-01-01

    Four mature Holstein cows in late lactation were blocked in two groups based on milk production, in a 2x2 reversal with 21-day periods, and fed: (A) control diet; (B) A plus 1 kg/day tallow. Cows were fed sorghum silage ad libitum. Blood samples were collected from the jugular vein on day 15, 17, and 19 of each period. Fat did not effect DM intake or milk yield, however milk CP yield was 20% lower. Plasma lipids increased 33.6%, glucose decreased 9% and insulin/glucagon ratio decreased 21.2% in cow fed fat. After period two, cows were slaughtered and mammary tissue sampled for incubation in Krebs Ringer bicarbonate buffer containing 22 AA at arterial concentration and .225 μCi/ml of 14 C-labelled L-Leu, L-Phe, L-Lys or D/L Met. Dietary fat decreased tissue AA uptake rate by 21.2%. Uptake was 4.8, 10.3, 17.8 and 2.4 x 10 -3 μM/min/gm of tissue DM for Phe, Lys, Leu and Met, respectively. Results suggest that dietary fat may decrease milk protein synthesis by lowering the rate of AA uptake

  2. Tracer experiment administering L-phenylalanine-U-14C and L-tyrosine-U-14C to the tissue slices of bamboo shoots

    International Nuclear Information System (INIS)

    Kozukue, E.; Mizuno, S.

    1987-01-01

    Uniformly 14 C-labeled L-phenylalanine and L-tyrosine were administered to tissue slices of both top and base sections of bamboo shoots. Alcohol soluble substances were extracted and then separated into organic acid, sugar and amino acid fractions by ion exchange chromatography. The homogentisic acid fraction among the organic acids was collected by high-performance liquid chromatography (HPLC) and its radioactivity was measured, while the alcohol insoluble residue was used for the analysis of lignin aldehyde by the method of alkaline nitrobenzene oxidation. 1. The two labeled amino acids were steadily incorporated into the tissues during incubation and rapidly converted to organic acid, sugar and alcohol insoluble residue, especially the latter. 2. On determining the amount of phenylalanine converted to tyrosine, it was found that this was extremely small. 3. The incorporation of phenylalanine-U- 14 C into alcohol insoluble residue was higher than that of tyrosine in both sections. 4. Although the conversion into lignin aldehyde from phenylalanine-U- 14 C was higher than that from tyrosine-U- 14 C, it was found that tyrosine incorporated into the shoots was converted to a remarkable extent for formation of lignin aldehyde. 5. The incorporation of phenylalanine and tyrosine into homogentisic acid was very low. From these results, we assume that the conversion of phenylalanine to tyrosine or of tyrosine to homogentisic acid is very small, and that a part of the high amount of tyrosine in the shoots may be used for formation of lignin

  3. Metabolism of 2,2′,3,3′,6,6′-Hexachlorobiphenyl (PCB 136) Atropisomers in Tissue Slices from Phenobarbital or Dexamethasone-Induced Rats is Sex-Dependent

    Science.gov (United States)

    Wu, Xianai; Kania-Korwel, Izabela; Chen, Hao; Stamou, Marianna; Dammanahalli, Karigowda J.; Duffel, Michael; Lein, Pamela J.; Lehmler, Hans-Joachim

    2013-01-01

    Chiral polychlorinated biphenyls (PCBs) such as PCB 136 enantioselectively sensitize the ryanodine receptor (RyR). In light of recent evidence that PCBs cause developmental neurotoxicity via RyR-dependent mechanisms, this suggests that enantioselective PCB metabolism may influence the developmental neurotoxicity of chiral PCBs. However, enantioselective disposition of PCBs has not been fully characterized.The effect of sex and cytochrome P450 (P450) enzyme induction on the enantioselective metabolism of PCB 136 was studied using liver tissue slices prepared from naïve control (CTL), phenobarbital (PB; CYP2B inducer) or dexamethasone (DEX; CYP3A inducer) pretreated adult Sprague-Dawley rats. PCB 136 metabolism was also examined in hippocampal slices derived from untreated rat pups.In liver tissue slices, hydroxylated PCB (OH-PCB) profiles depended on sex and inducer pretreatment, and OH-PCB levels followed the rank orders male > female and PB > DEX > CTL. In contrast, the enantiomeric enrichment of PCB 136 and its metabolites was independent of sex and inducer pretreatment. Only small amounts of PCB 136 partitioned into hippocampal tissue slices and no OH-PCB metabolites were detected.Our results suggest that enantioselective metabolism, sex and induction status of P450 enzymes in the liver may modulate the neurotoxic outcomes of developmental exposure to chiral PCBs. PMID:23581876

  4. Tracer experiment administering L-phenylalanine-U-{sup 14}C and L-tyrosine-U-{sup 14}C to the tissue slices of bamboo shoots

    Energy Technology Data Exchange (ETDEWEB)

    Kozukue, E. [Kenmei Women' s Junior Coll., Himeji, Hyogo (Japan); Mizuno, S.

    1987-09-15

    Uniformly {sup 14}C-labeled L-phenylalanine and L-tyrosine were administered to tissue slices of both top and base sections of bamboo shoots. Alcohol soluble substances were extracted and then separated into organic acid, sugar and amino acid fractions by ion exchange chromatography. The homogentisic acid fraction among the organic acids was collected by high-performance liquid chromatography (HPLC) and its radioactivity was measured, while the alcohol insoluble residue was used for the analysis of lignin aldehyde by the method of alkaline nitrobenzene oxidation. 1. The two labeled amino acids were steadily incorporated into the tissues during incubation and rapidly converted to organic acid, sugar and alcohol insoluble residue, especially the latter. 2. On determining the amount of phenylalanine converted to tyrosine, it was found that this was extremely small. 3. The incorporation of phenylalanine-U-{sup 14}C into alcohol insoluble residue was higher than that of tyrosine in both sections. 4. Although the conversion into lignin aldehyde from phenylalanine-U-{sup 14}C was higher than that from tyrosine-U-{sup 14}C, it was found that tyrosine incorporated into the shoots was converted to a remarkable extent for formation of lignin aldehyde. 5. The incorporation of phenylalanine and tyrosine into homogentisic acid was very low. From these results, we assume that the conversion of phenylalanine to tyrosine or of tyrosine to homogentisic acid is very small, and that a part of the high amount of tyrosine in the shoots may be used for formation of lignin.

  5. NDA issues with RFETS vitrified waste forms

    International Nuclear Information System (INIS)

    Hurd, J.; Veazey, G.

    1998-01-01

    A study was conducted at Los Alamos National Laboratory (LANL) for the purpose of determining the feasibility of using a segmented gamma scanner (SGS) to accurately perform non-destructive analysis (NDA) on certain Rocky Flats Environmental Technology Site (RFETS) vitrified waste samples. This study was performed on a full-scale vitrified ash sample prepared at LANL according to a procedure similar to that anticipated to be used at RFETS. This sample was composed of a borosilicate-based glass frit, blended with ash to produce a Pu content of ∼1 wt %. The glass frit was taken to a degree of melting necessary to achieve a full encapsulation of the ash material. The NDA study performed on this sample showed that SGSs with either 1/2- or 2-inch collimation can achieve an accuracy better than 6 % relative to calorimetry and γ-ray isotopics. This accuracy is achievable, after application of appropriate bias corrections, for transmissions of about 1/2 % through the waste form and counting times of less than 30 minutes. These results are valid for ash material and graphite fines with the same degree of plutonium particle size, homogeneity, sample density, and sample geometry as the waste form used to obtain the results in this study. A drum-sized thermal neutron counter (TNC) was also included in the study to provide an alternative in the event the SGS failed to meet the required level of accuracy. The preliminary indications are that this method will also achieve the required accuracy with counting times of ∼30 minutes and appropriate application of bias corrections. The bias corrections can be avoided in all cases if the instruments are calibrated on standards matching the items

  6. Autoradiography after incubation of tissue slices in 111 In-pentetreotide. Demonstration of the feasibility of the technique on rat brain slices. Application in two cases of human renal cell carcinoma

    International Nuclear Information System (INIS)

    Montravers, F.; Allard, S.; Fouret, P.; Daty, N.; Talbot, J.N.; Bernaudin, J.F.

    1996-01-01

    We report on a macroscopic autoradiographic technique using 111 In-pentetreotide after in vitro incubation of the slices. The feasibility of this technique has been demonstrated by the actual labeling of the deeper layers of the rat cerebral cortex, corresponding to the known cerebral distribution of somatostatin subtype 2 receptor. This technique has subsequently been applied in two of human renal cell carcinoma and has proven the presence of somatostatin receptors in both tumours. In one of these cases, a preoperative scintigraphy using 111 In-pentetreotide showed the absence of tumour visualization. The mechanism proposed to explain this discrepancy between scintigraphic and autoradiographic results is a lack of accessibility of the somatostatin analog to the receptor in case of voluminous renal tumour. (authors). 19 refs., 2 figs

  7. Thick Slice and Thin Slice Teaching Evaluations

    Science.gov (United States)

    Tom, Gail; Tong, Stephanie Tom; Hesse, Charles

    2010-01-01

    Student-based teaching evaluations are an integral component to institutions of higher education. Previous work on student-based teaching evaluations suggest that evaluations of instructors based upon "thin slice" 30-s video clips of them in the classroom correlate strongly with their end of the term "thick slice" student evaluations. This study's…

  8. Vitrified chemically bonded phosphate ceramics for immobilization of radioisotopes

    Science.gov (United States)

    Wagh, Arun S.

    2016-04-05

    A method of immobilizing a radioisotope and vitrified chemically bonded phosphate ceramic (CBPC) articles formed by the method are described. The method comprises combining a radioisotope-containing material, MgO, a source of phosphate, and optionally, a reducing agent, in water at a temperature of less than 100.degree. C. to form a slurry; curing the slurry to form a solid intermediate CBPC article comprising the radioisotope therefrom; comminuting the intermediate CBPC article, mixing the comminuted material with glass frits, and heating the mixture at a temperature in the range of about 900 to about 1500.degree. C. to form a vitrified CBPC article comprising the radioisotope immobilized therein.

  9. Providing flexibility in spent fuel and vitrified waste management

    International Nuclear Information System (INIS)

    Bradley, N.; O'Tallamhain, C.; Brown, G.A.

    1986-01-01

    The UK Central Electricity Generating Board is pondering a decision to build a dry vault store as a buffer in its overall AGR spent fuel management programme. The application of the dry vault is not limited to fuel from gas cooled reactors, it can be used for spent LWR fuel and vitrified waste. A cutaway diagram of such a vault is presented. (UK)

  10. Return of vitrified wastes from France to Japan

    International Nuclear Information System (INIS)

    2000-01-01

    The radioactive wastes resulting from the burnup of nuclear fuels in nuclear reactors represent 3 to 5% of the spent fuel. These wastes cannot be reused nor recycled and thus are vitrified after reprocessing. Japanese power companies have signed contracts with Cogema in France and BNFL in the UK for the reprocessing of their spent fuels. Then, the ultimate reprocessed wastes are sent back to Japan for storage. This information dossier takes stock of different questions relative to the transport of the vitrified wastes from France to Japan: why France sends back containers of vitrified wastes to Japan? What is a vitrified wastes container made of? How containers are transported? What is the regulatory frame applicable to these transports? Which safety measures are taken during transport? Which physical protection is applied? Which temporary storage facilities are used before and after transportation? How is performed the ultimate storage of wastes in Japan? Which quality and safety warranties are taken? Which emergency plans and exercises are provided? What are the applicable civil liability regimes? And what kind of information is given to the public about these transports. Some general information about energy and nuclear power worldwide, energy and environment, radioactivity, BNFL, Cogema and ORC is given in appendixes. (J.S.)

  11. Low temperature irradiation of vitrifiable mixtures of unsaturated monomers

    International Nuclear Information System (INIS)

    Kaetsu, I.; Ito, A.; Hayashi, K.

    1975-01-01

    A specific mixture containing at least one polymerizable unsaturated monomer which is not vitrifiable by itself can advantageously be polymerized by irradiating the mixture at a temperature not higher than 100 0 C above glass transition temperature of the mixture with an ionizing radiation and/or a light. 12 claims, 6 drawings, figures

  12. European experience in transport/storage cask for vitrified residues

    International Nuclear Information System (INIS)

    Otton, Camille; Sicard, Damien

    2007-01-01

    Available in abstract form only. Full text of publication follows: Because of the evolution of burnup of spent fuel to be reprocessed, the high activity vitrified residues would not be transported in the existing cask designs. Therefore, TN International has decided in the late nineties to develop a brand new design of casks with optimized capacity able to store and transport the most active and hottest canisters: the TN TM 81 casks currently in use in Switzerland and the TN TM 85 cask which shall permit in the near future in Germany the storage and the transport of the most active vitrified residues defining a thermal power of 56 kW (kilowatts). The challenges for the TN TM 81 and TN TM 85 cask designs were that the geometry entry data were very restrictive and were combined with a fairly wide range set by the AREVA NC Specification relative to vitrified residue canister. The TN TM 81 and the TN TM 85 casks have been designed to fully anticipate shipment constraints of the present vitrified residue production. It also used the feedback of current shipments and the operational constraints and experience of receiving and shipping facilities. The casks had to fit as much as possible in the existing procedures for the already existing flasks such as the TN TM 28 cask and TS 28 V cask, all along the logistics chain of loading, unloading, transport and maintenance. (authors)

  13. Statistical estimate for evaluation of vitrified radioactive wastes

    International Nuclear Information System (INIS)

    Jedinakova-Krizova, V.; Dvorak, Z.

    1994-01-01

    The evaluation of experimental results by methods of mathematical statistics gave a chance to derive a number of conclusions on the leachability of vitrified radioactive wastes. Practical application of this procedure requires that the ratio of Na and K concentration in the solution should be independent of the leaching time- The actual value of this ratio is influenced. above all. by the properties of the glass matrix. These results confirm the ion that Na/K correlation found could be extended for the determination of the Na/ 137 Cs concentration ratio. This finding was used for the application of a ln-ln correlation, while evaluation the quality of vitrified radioactive wastes products. (author) 7 refs.; 5 figs.; 1 tab

  14. Properties of vitrified rocky flats TRUW with different waste loadings

    International Nuclear Information System (INIS)

    Eddy, T.L.; Sears, J.W.; Grandy, J.D.; Miley, D.V.; Erickson, A.W.; Farnsworth, R.N.; Larsen, E.D.

    1994-01-01

    Leach rates, phase structures, and mechanical properties of simulated Rocky Flats Plant 1st and 2nd slate sludge vitrified in an arc melter are described as a function of waste to soil fraction and method of devitrification to produce the glass-ceramic waste form. Volatile, hazardous, and transuranic (TRU) surrogate metals were added to assess dissolution effects. Zirconia and titania were also added to confirm their ability as transuranic-surrogate getters

  15. Slice hyperholomorphic Schur analysis

    CERN Document Server

    Alpay, Daniel; Sabadini, Irene

    2016-01-01

    This book defines and examines the counterpart of Schur functions and Schur analysis in the slice hyperholomorphic setting. It is organized into three parts: the first introduces readers to classical Schur analysis, while the second offers background material on quaternions, slice hyperholomorphic functions, and quaternionic functional analysis. The third part represents the core of the book and explores quaternionic Schur analysis and its various applications. The book includes previously unpublished results and provides the basis for new directions of research.

  16. The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: How can we minimize the risk for deterministic effects?

    International Nuclear Information System (INIS)

    Perisinakis, Kostas; Seimenis, Ioannis; Tzedakis, Antonis; Papadakis, Antonios E.; Damilakis, John

    2013-01-01

    Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peak tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of

  17. The virtual slice setup.

    Science.gov (United States)

    Lytton, William W; Neymotin, Samuel A; Hines, Michael L

    2008-06-30

    In an effort to design a simulation environment that is more similar to that of neurophysiology, we introduce a virtual slice setup in the NEURON simulator. The virtual slice setup runs continuously and permits parameter changes, including changes to synaptic weights and time course and to intrinsic cell properties. The virtual slice setup permits shocks to be applied at chosen locations and activity to be sampled intra- or extracellularly from chosen locations. By default, a summed population display is shown during a run to indicate the level of activity and no states are saved. Simulations can run for hours of model time, therefore it is not practical to save all of the state variables. These, in any case, are primarily of interest at discrete times when experiments are being run: the simulation can be stopped momentarily at such times to save activity patterns. The virtual slice setup maintains an automated notebook showing shocks and parameter changes as well as user comments. We demonstrate how interaction with a continuously running simulation encourages experimental prototyping and can suggest additional dynamical features such as ligand wash-in and wash-out-alternatives to typical instantaneous parameter change. The virtual slice setup currently uses event-driven cells and runs at approximately 2 min/h on a laptop.

  18. Evaluation of shipping doses and compositions for vitrified waste

    International Nuclear Information System (INIS)

    Shapiro, A.

    1996-01-01

    Shipments of radioactive materials must adhere to dose limits specified in the Code of Federal Regulations. This paper discusses methods for evaluating shipping doses of vitrified waste. A methodology was developed for evaluating the change in vitrification composition required to maintain shipping dose rates within limits. The point kernel codes QAD and Microshield were used to evaluate dose equivalent rates from specified waste forms and radioactivity measurements. The Origen code was utilized to provide the gamma-ray activity as a function of time from isotopic activity measurements. This gamma-ray activity served as source input for QAD. Microshield developed its own source from the given isotopic activities

  19. Characterisation of Plasma Vitrified Simulant Plutonium Contaminated Material Waste

    International Nuclear Information System (INIS)

    Hyatt, Neil C.; Morgan, Suzy; Stennett, Martin C.; Scales, Charlie R.; Deegan, David

    2007-01-01

    The potential of plasma vitrification for the treatment of a simulant Plutonium Contaminated Material (PCM) was investigated. It was demonstrated that the PuO 2 simulant, CeO 2 , could be vitrified in the amorphous calcium iron aluminosilicate component of the product slag with simultaneous destruction of the organic and polymer waste fractions. Product Consistency Tests conducted at 90 deg. C in de-ionised water and buffered pH 11 solution show the PCM slag product to be durable with respect to release of Ce. (authors)

  20. Novel High-Viscosity Polyacrylamidated Chitosan for Neural Tissue Engineering: Fabrication of Anisotropic Neurodurable Scaffold via Molecular Disposition of Persulfate-Mediated Polymer Slicing and Complexation

    Directory of Open Access Journals (Sweden)

    Viness Pillay

    2012-10-01

    Full Text Available Macroporous polyacrylamide-grafted-chitosan scaffolds for neural tissue engineering were fabricated with varied synthetic and viscosity profiles. A novel approach and mechanism was utilized for polyacrylamide grafting onto chitosan using potassium persulfate (KPS mediated degradation of both polymers under a thermally controlled environment. Commercially available high molecular mass polyacrylamide was used instead of the acrylamide monomer for graft copolymerization. This grafting strategy yielded an enhanced grafting efficiency (GE = 92%, grafting ratio (GR = 263%, intrinsic viscosity (IV = 5.231 dL/g and viscometric average molecular mass (MW = 1.63 × 106 Da compared with known acrylamide that has a GE = 83%, GR = 178%, IV = 3.901 dL/g and MW = 1.22 × 106 Da. Image processing analysis of SEM images of the newly grafted neurodurable scaffold was undertaken based on the polymer-pore threshold. Attenuated Total Reflectance-FTIR spectral analyses in conjugation with DSC were used for the characterization and comparison of the newly grafted copolymers. Static Lattice Atomistic Simulations were employed to investigate and elucidate the copolymeric assembly and reaction mechanism by exploring the spatial disposition of chitosan and polyacrylamide with respect to the reactional profile of potassium persulfate. Interestingly, potassium persulfate, a peroxide, was found to play a dual role initially degrading the polymers—“polymer slicing”—thereby initiating the formation of free radicals and subsequently leading to synthesis of the high molecular mass polyacrylamide-grafted-chitosan (PAAm-g-CHT—“polymer complexation”. Furthermore, the applicability of the uniquely grafted scaffold for neural tissue engineering was evaluated via PC12 neuronal cell seeding. The novel PAAm-g-CHT exhibited superior neurocompatibility in terms of cell infiltration owing to the anisotropic porous architecture, high molecular mass mediated robustness

  1. Local geology controlled the feasibility of vitrifying Iron Age buildings.

    Science.gov (United States)

    Wadsworth, Fabian B; Heap, Michael J; Damby, David E; Hess, Kai-Uwe; Najorka, Jens; Vasseur, Jérémie; Fahrner, Dominik; Dingwell, Donald B

    2017-01-12

    During European prehistory, hilltop enclosures made from polydisperse particle-and-block stone walling were exposed to temperatures sufficient to partially melt the constituent stonework, leading to the preservation of glassy walls called 'vitrified forts'. During vitrification, the granular wall rocks partially melt, sinter viscously and densify, reducing inter-particle porosity. This process is strongly dependent on the solidus temperature, the particle sizes, the temperature-dependence of the viscosity of the evolving liquid phase, as well as the distribution and longevity of heat. Examination of the sintering behaviour of 45 European examples reveals that it is the raw building material that governs the vitrification efficiency. As Iron Age forts were commonly constructed from local stone, we conclude that local geology directly influenced the degree to which buildings were vitrified in the Iron Age. Additionally, we find that vitrification is accompanied by a bulk material strengthening of the aggregates of small sizes, and a partial weakening of larger blocks. We discuss these findings in the context of the debate surrounding the motive of the wall-builders. We conclude that if wall stability by bulk strengthening was the desired effect, then vitrification represents an Iron Age technology that failed to be effective in regions of refractory local geology.

  2. PLUTONIUM/HIGH-LEVEL VITRIFIED WASTE BDBE DOSE CALCULATION

    Energy Technology Data Exchange (ETDEWEB)

    J.A. Ziegler

    2000-11-20

    The purpose of this calculation is to provide a dose consequence analysis of high-level waste (HLW) consisting of plutonium immobilized in vitrified HLW to be handled at the proposed Monitored Geologic Repository at Yucca Mountain for a beyond design basis event (BDBE) under expected conditions using best estimate values for each calculation parameter. In addition to the dose calculation, a plutonium respirable particle size for dose calculation use is derived. The current concept for this waste form is plutonium disks enclosed in cans immobilized in canisters of vitrified HLW (i.e., glass). The plutonium inventory at risk used for this calculation is selected from Plutonium Immobilization Project Input for Yucca Mountain Total Systems Performance Assessment (Shaw 1999). The BDBE examined in this calculation is a nonmechanistic initiating event and the sequence of events that follow to cause a radiological release. This analysis will provide the radiological releases and dose consequences for a postulated BDBE. Results may be considered in other analyses to determine or modify the safety classification and quality assurance level of repository structures, systems, and components. This calculation uses best available technical information because the BDBE frequency is very low (i.e., less than 1.0E-6 events/year) and is not required for License Application for the Monitored Geologic Repository. The results of this calculation will not be used as part of a licensing or design basis.

  3. Portable Device Slices Thermoplastic Prepregs

    Science.gov (United States)

    Taylor, Beverly A.; Boston, Morton W.; Wilson, Maywood L.

    1993-01-01

    Prepreg slitter designed to slit various widths rapidly by use of slicing bar holding several blades, each capable of slicing strip of preset width in single pass. Produces material evenly sliced and does not contain jagged edges. Used for various applications in such batch processes involving composite materials as press molding and autoclaving, and in such continuous processes as pultrusion. Useful to all manufacturers of thermoplastic composites, and in slicing B-staged thermoset composites.

  4. Synthesis long life storage studies surface storage of vitrified wastes

    International Nuclear Information System (INIS)

    Beziat, A.; Breton, E.; Ranc, G.; Gaillard, J.P.; Lagrave, H.; Hollender, F.; Jourdain, F.; Piault, E.; Garnier, J.; Lamare, V.; Duret, B.; Helie, M.; Ferry, C.; Mijuin, D.; Gagnier, E.

    2004-01-01

    This document is realized in the framework of the axis 3 of the law of 1991 on the radioactive wastes management. It justifies the choices concerning long time surface storage installation of vitrified wastes, called high activity wastes. The long time of the installation would reach 300 years at the maximum. These wastes represent 1 % at the maximum, of radioactive wastes in France but 95 % of the whole radioactivity. Three main objectives were followed: provide a permanent containment of radionuclides; give the possibility of wastes containers retrieval at all the time; minimize the maintenance and the control. The results allow to conclude that the long time surface storage of high activity wastes is feasible. (A.L.B.)

  5. Operational and safety aspects of vitrified waste casks

    International Nuclear Information System (INIS)

    Kirchner, B.

    1993-01-01

    For the time being two technical solutions have been developed for the interim storage: 1) one is based on forced air cooled pits set out in a concrete structure, as presently provided close to the Vitrification Facilities on reprocessing sites; 2) the other one is based on transportable storage casks standing vertically onto a storage pad, following principles similar to those already experienced with spent fuel storage casks. Considering these two solutions for interim storage, TRANSNUCLEAIRE has developed two main types of transportable casks for vitrified HAW; one is a routine transport cask; the other one is a transportable storage cask. Both are covered by the generic name TN28V and have already been described in previous papers. This paper deals with the safety and operation aspects of the casks under both transport and storage conditions. (J.P.N.)

  6. Comparing technical concepts for disposal of Belgian vitrified HLW

    International Nuclear Information System (INIS)

    Bel, J.; Bock, C. de; Boyazis, J.P.

    2004-01-01

    The choice of a suitable repository design for different categories of radioactive waste is an important element in the decisional process that will eventually lead to the waste disposal in geological ground layers during the next decades. Most countries are in the process of elaborating different technical solutions for their EBS '. Considering possible design alternatives offers more flexibility to cope with remaining uncertainties and allows optimizing some elements of the EBS in the future. However, it is not feasible to continue carrying out detailed studies for a large number of alternative design options. At different stages in the decisional process, choices, even preliminary ones, have to be made. Although the impact of different stakeholders (regulator, waste agencies, waste producers, research centers,...) in making these design choices can differ from one country to another, the choices should be based on sound, objective, clear and unambiguous justification grounds. Moreover, the arguments should be carefully reported and easy to understand by the decision makers. ONDRAF/NIRAS recently elaborated three alternative designs for the disposal of vitrified HLW. These three designs are briefly described in the next section. A first series of technological studies pointed out that the three options are feasible. It would however be unreasonable to continue R and D work on all three alternatives in parallel. It is therefore planned to make a preliminary choice of a reference design for the vitrified HLW in 2003. This selection will depend on the way the alternative design options can be evaluated against a number of criteria, mainly derived from general repository design requirements. The technique of multi-criteria analysis (MCA) will be applied as a tool for making the optimum selection, considering all selection criteria and considering different strategic approaches. This paper describes the used methodology. The decision on the actual selection will be

  7. Study on behaviour in long term of vitrified materials

    International Nuclear Information System (INIS)

    Vernaz, E.

    1993-01-01

    In collaboration with EDF (Electricite de France), after testing fusion of Refiom (Residus d'Epuration des Fumees d'Incineration d'Ordures Menageres), residues from purification of incineration smokes of household rubbish, realised at Porcheville and at the Laboratory of Renardieres with experimental processing of vitrification by plasma, CEA (Centre d'Etudes Atomiques), atomic center of research, began study on resistance in long term of vitrified products. From about thirty five years, CEA carries out research to confine radioactive waste of high activity in stable materials. Glass was the first best one which allowed to incorporate about thirty different chemical elements found in fission products solutions into a stable die with a good chemical durability; three vitrification shops raised, one at Marcoule ('AVM', 1978) in the south of France, the two other ones at La Hague ('R7', 1989 and 'T7', 1992) in Normandy. To determine a possible impact of a deep radioactive waste disposal on human and environment, several studies began. In particular, studies on aqueous corrosion of glasses to determine behaviour in long term of glass package (first barrier of confinement) and to estimate kinetics of releasing confined toxical elements on periods of several thousands years. Principal results are exposed in this conference. Experience shows that safety analysis cannot be based on long term extrapolation of a simple lixiviation result. This analysis must include: a sufficient knowledge in basic mechanisms of alteration to predict the kinetic evolution in a long term. To take in account environment conditions with a normal or accidental scheme (acidity, clay, organic compounds,...). This knowledge broadly developed by CEA for nuclear glasses seems to be easily transposable to different wastes (industrial ones or from hospitals) and takes place in a contract of research CEA/EDF to valorize vitrified products. 9 figs. 4 refs

  8. The generation of live offspring from vitrified oocytes.

    Directory of Open Access Journals (Sweden)

    L Gabriel Sanchez-Partida

    Full Text Available Oocyte cryopreservation is extremely beneficial for assisted reproductive technologies, the treatment of infertility and biotechnology and offers a viable alternative to embryo freezing and ovarian grafting approaches for the generation of embryonic stem cells and live offspring. It also offers the potential to store oocytes to rescue endangered species by somatic cell nuclear transfer and for the generation of embryonic stem cells to study development in these species. We vitrified mouse oocytes using a range of concentrations of trehalose (0 to 0.3 M and demonstrated that 0.1 and 0.3 M trehalose had similar developmental rates, which were significantly different to the 0.2 M cohort (P<0.05. As mitochondria are important for fertilisation outcome, we observed that the clustering and distribution of mitochondria of the 0.2 M cohort were more affected by vitifrication than the other groups. Nevertheless, all 3 cohorts were able to develop to blastocyst, following in vitro fertilisation, although developmental rates were better for the 0.1 and 0.3 M cohorts than the 0.2 M cohort (P<0.05. Whilst blastocysts gave rise to embryonic stem-like cells, it was apparent from immunocytochemistry and RT-PCR that these cells did not demonstrate true pluripotency and exhibited abnormal karyotypes. However, they gave rise to teratomas following injection into SCID mice and differentiated into cells of each of the germinal layers following in vitro differentiation. The transfer of 2-cell embryos from the 0.1 and 0.3 M cohorts resulted in the birth of live offspring that had normal karyotypes (9/10. When 2-cell embryos from vitrified oocytes underwent vitrification, and were thawed and transferred, live offspring were obtained that exhibited normal karyotypes, with the exception of one offspring who was larger and died at 7 months. We conclude that these studies highlight the importance of the endometrial environment for the maintenance of genetic stability and

  9. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  10. Pre-disposal storage, transport and handling of vitrified high level waste

    International Nuclear Information System (INIS)

    Kempe, T.F.; Martin, A.

    1981-05-01

    The objectives of the study were to review non site-specific engineering features of the storage, transport and handling of vitrified high level radioactive waste prior to its transfer into an underground repository, and to identify those features which require validation or development. Section headings are: introduction (historical and technical background); characteristics and arisings of vitrified high level waste; overpacks (additional containment barrier, corrosion resistant); interim storage of HLW; transport of HLW; handling; conclusions and recommendations. (U.K.)

  11. Trafficking of astrocytic vesicles in hippocampal slices

    International Nuclear Information System (INIS)

    Potokar, Maja; Kreft, Marko; Lee, So-Young; Takano, Hajime; Haydon, Philip G.; Zorec, Robert

    2009-01-01

    The increasingly appreciated role of astrocytes in neurophysiology dictates a thorough understanding of the mechanisms underlying the communication between astrocytes and neurons. In particular, the uptake and release of signaling substances into/from astrocytes is considered as crucial. The release of different gliotransmitters involves regulated exocytosis, consisting of the fusion between the vesicle and the plasma membranes. After fusion with the plasma membrane vesicles may be retrieved into the cytoplasm and may continue to recycle. To study the mobility implicated in the retrieval of secretory vesicles, these structures have been previously efficiently and specifically labeled in cultured astrocytes, by exposing live cells to primary and secondary antibodies. Since the vesicle labeling and the vesicle mobility properties may be an artifact of cell culture conditions, we here asked whether the retrieving exocytotic vesicles can be labeled in brain tissue slices and whether their mobility differs to that observed in cell cultures. We labeled astrocytic vesicles and recorded their mobility with two-photon microscopy in hippocampal slices from transgenic mice with fluorescently tagged astrocytes (GFP mice) and in wild-type mice with astrocytes labeled by Fluo4 fluorescence indicator. Glutamatergic vesicles and peptidergic granules were labeled by the anti-vesicular glutamate transporter 1 (vGlut1) and anti-atrial natriuretic peptide (ANP) antibodies, respectively. We report that the vesicle mobility parameters (velocity, maximal displacement and track length) recorded in astrocytes from tissue slices are similar to those reported previously in cultured astrocytes.

  12. Development of improved leaching techniques for vitrified radioactive waste products

    International Nuclear Information System (INIS)

    Vaswani, G.A.; Yeotikar, R.G.; Rastogi, R.C.; Sunder Rajan, N.S.

    1979-01-01

    A critical review of the current techniques for evaluating the leach resistance of vitrified radioactive wastes has been made. Inadequacy of the available leaching techniques, with respect to their adoption as standard technique on an international scale, has been brought out for the three broad catagories of aqueous attack viz., (i) simple contact with leachant at a particular temperature, (ii) once-through or recirculatory flow of leachant at variable temperatures and flow rates, and (iii) contact with freshly distilled hot water in soxhelet type of extractor. In an effort to evolve a standard leaching technique in the latter two categories of aqueous attack, development of two leaching units viz., 'Dynamic Leaching Unit' and 'Modified Soxhlet Unit' is described. Both these units offer good control and wide flexibility on the important parameters affecting leaching such as leachant temperature, flow rate of residence time of leachant and ratio of leachant volume to sample surface area. The dynamic leaching units also offers a good control and flexibility on the two additional parameters viz., the composition and pH of the leachant. In the modified soxhlet unit the composition and pH of the leachant remains near to that of distilled water. The leach rate results have been found to be reproducible. A need for framing the set of standard conditions for adoption of these units in evolution of standard leaching techniques has been indicated. (auth.)

  13. Influence of the slice thickness in CT to clinical effect

    International Nuclear Information System (INIS)

    Kimura, Kazue; Katakura, Toshihiko; Ito, Masami; Okuaki, Okihisa; Suzuki, Kenji

    1980-01-01

    CT is a kind of tomography. Therefore, what thickness of tissue is being observed in the picture - this is important in the clinical application of CT. The influence of slice thickness on the pictures, especially its clinical effect, was examined. The apparatus used is EMI CT 5005. For varying the slice thickness, it cannot be any larger than the thickness essential to the apparatus. Therefore, to make it thinner than the essential 14 mm, collimators were specially prepared, which were used on the sides of an X-ray tube and a detector. As basic observation, the revelation ability of form owing to the difference of slice thickness using acryl pipes, and the revelation ability of slice face owing to the difference of slice thickness, were examined. About clinical observation, the results for certain cases of cancer were compared with the CT images for the slice thickness of 14 mm essential to EMI CT 5005 and the slice thickness of 7 mm achieved by means of the collimators. (J.P.N.)

  14. Estimation of the heat generation in vitrified waste product and shield thickness of the cask for the transportation of vitrified waste product using Monte Carlo technique

    International Nuclear Information System (INIS)

    Deepa, A.K.; Jakhete, A.P.; Mehta, D.; Kaushik, C.P.

    2011-01-01

    High Level Liquid waste (HLW) generated during reprocessing of spent fuel contains most of the radioactivity present in the spent fuel resulting in the need for isolation and surveillance for extended period of time. Major components in HLW are the corrosion products, fission products such as 137 Cs, 90 Sr, 106 Ru, 144 Ce, 125 Sb etc, actinides and various chemicals used during reprocessing of spent fuel. Fresh HLW having an activity concentration of around 100Ci/l is to be vitrified into borosilicate glass and packed in canisters which are placed in S.S overpacks for better confinement. These overpacks contain around 0.7 Million Curies of activity. Characterisation of activity in HLW and activity profile of radionuclides for various cooling periods sets the base for the study. For transporting the vitrified waste product (VWP), two most important parameters is the shield thickness of the transportation cask and the heat generation in the waste product. This paper describes the methodology used in the estimation of lead thickness for the transportation cask using the Monte Carlo Technique. Heat generation due to decay of fission products results in the increase in temperature of the vitrified waste product during interim storage and disposal. Glass being the material, not having very high thermal conductivity, temperature difference between the canister and surrounding bears significance in view of the possibility of temperature based devitrification of VWP. The heat generation in the canister and the overpack containing vitrified glass is also estimated using MCNP. (author)

  15. The time slice system

    International Nuclear Information System (INIS)

    DeWitt, J.

    1990-01-01

    We have designed a fast readout system for silicon microstrip detectors which could be used at HERA, LHC, and SSC. The system consists of an analog amplifier-comparator chip (AACC) and a digital time slice chip (DTSC). The analog ship is designed in dielectric isolated bipolar technology for low noise and potential radiation hardness. The DTSC is built in CMOS for low power use and high circuit density. The main implementation aims are low power consumption and compactness. The architectural goal is automatic data reduction, and ease of external interface. The pipelining of event information is done digitally in the DTSC. It has a 64 word deep level 1 buffer acting as a FIFO, and a 16 word deep level 2 buffer acting as a dequeue. The DTSC also includes an asynchronous bus interface. We are first building a scaled up (100 μm instead of 25 μm pitch) and slower (10 MHz instead of 60 MHz) version in 2 μm CMOS and plan to test the principle of operation of this system in the Leading Proton Spectrometer (LPS) of the ZEUS detector at HERA. Another very important development will be tested there: the radiation hardening of the chips. We have started a collaboration with a rad-hard foundry and with Los Alamos National Laboratories to test and evaluate rad-hard processes and the final rad-hard product. Initial data are very promising, because radiation resistance of up to many Mrad have been achieved. (orig.)

  16. A simple method for multiday imaging of slice cultures.

    Science.gov (United States)

    Seidl, Armin H; Rubel, Edwin W

    2010-01-01

    The organotypic slice culture (Stoppini et al. A simple method for organotypic cultures of nervous tissue. 1991;37:173-182) has become the method of choice to answer a variety of questions in neuroscience. For many experiments, however, it would be beneficial to image or manipulate a slice culture repeatedly, for example, over the course of many days. We prepared organotypic slice cultures of the auditory brainstem of P3 and P4 mice and kept them in vitro for up to 4 weeks. Single cells in the auditory brainstem were transfected with plasmids expressing fluorescent proteins by way of electroporation (Haas et al. Single-cell electroporation for gene transfer in vivo. 2001;29:583-591). The culture was then placed in a chamber perfused with oxygenated ACSF and the labeled cell imaged with an inverted wide-field microscope repeatedly for multiple days, recording several time-points per day, before returning the slice to the incubator. We describe a simple method to image a slice culture preparation during the course of multiple days and over many continuous hours, without noticeable damage to the tissue or photobleaching. Our method uses a simple, inexpensive custom-built insulator constructed around the microscope to maintain controlled temperature and uses a perfusion chamber as used for in vitro slice recordings. (c) 2009 Wiley-Liss, Inc.

  17. Cross border transport of vitrified residues from France to Germany

    International Nuclear Information System (INIS)

    Graf, W.; Jussofie, A.

    2016-01-01

    Until 1994 reprocessing was the only legal way to manage German spent fuel. Since in 1984 the national reprocessing concept was abandoned the reprocessing abroad was the only existing disposal route. With the amendment of the Atomic Energy Act in 2002 spent fuel management changed completely since from 1 June 2005 any delivery of spent fuel to reprocessing plants was prohibited and the direct disposal of spent fuel became mandatory. Until 2005 the total amount of spent fuel to be reprocessed abroad added up to 6080 t HM, 5309 t HM thereof in France. According to the commercial contracts signed between the German utilities and COGEMA, now AREVA NC, in France and BNFL, now INS in UK, and to the intergovernmental agreements concluded between Germany and France or UK the waste generated from reprocessing has to be returned to Germany. The return of high active vitrified waste from La Hague to the interim storage facility at Gorleben was not only demanding from the view of safety ensured by the cask design but especially for security reasons since the Gorleben area served as a target for nuclear opponents from the first transport in 1996 to the latest one in 2010. The protection against sabotage of the railway lines and mass protests needed improved security measures. Special working forces and projects have been set up in France and Germany to cope with this situation. A complex transport organization was necessary to involve all parties in line with the German and French security requirements during transport. All transports have been completed successfully so far thus confirming the efficiency of the applied measures. (author)

  18. Geometry Processing of Conventionally Produced Mouse Brain Slice Images.

    Science.gov (United States)

    Agarwal, Nitin; Xu, Xiangmin; Gopi, M

    2018-04-21

    Brain mapping research in most neuroanatomical laboratories relies on conventional processing techniques, which often introduce histological artifacts such as tissue tears and tissue loss. In this paper we present techniques and algorithms for automatic registration and 3D reconstruction of conventionally produced mouse brain slices in a standardized atlas space. This is achieved first by constructing a virtual 3D mouse brain model from annotated slices of Allen Reference Atlas (ARA). Virtual re-slicing of the reconstructed model generates ARA-based slice images corresponding to the microscopic images of histological brain sections. These image pairs are aligned using a geometric approach through contour images. Histological artifacts in the microscopic images are detected and removed using Constrained Delaunay Triangulation before performing global alignment. Finally, non-linear registration is performed by solving Laplace's equation with Dirichlet boundary conditions. Our methods provide significant improvements over previously reported registration techniques for the tested slices in 3D space, especially on slices with significant histological artifacts. Further, as one of the application we count the number of neurons in various anatomical regions using a dataset of 51 microscopic slices from a single mouse brain. To the best of our knowledge the presented work is the first that automatically registers both clean as well as highly damaged high-resolutions histological slices of mouse brain to a 3D annotated reference atlas space. This work represents a significant contribution to this subfield of neuroscience as it provides tools to neuroanatomist for analyzing and processing histological data. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Improved parthenogenetic development of vitrified-warmed bovine oocytes activated with 9% ethanol plus 6-DMAP

    DEFF Research Database (Denmark)

    Hou, Y -p; Liu, Ying; Dai, Y -p

    2009-01-01

    The objective was to compare various activation protocols on developmental potential of vitrified bovine oocytes. Bovine oocytes matured in vitro for 23 h were vitrified with EDFSF30 in open pulled straws. After warming, they were cultured in vitro for 1 h, followed by parthenogenetic activation....... Vitrified-warmed oocytes had a morphologically normal rate similar to that of controls (nonvitrified oocytes cultured in vitro for 24 h; 98.6% vs. 100%, P > 0.05). When vitrified-warmed oocytes were first activated with 7% ethanol for 5 min and then incubated in 6-dimethylaminopurin (6-DMAP) for 4 h...... (for 5 min) or in combination with 6-DMAP (4 h) was used to activate vitrified-warmed oocytes, cleavage rates ranged from 22.3% to 61.1% and blastocyst rates ranged from 1.1% to 30.6%. These rates were optimized when oocytes were treated with 9% ethanol plus 6-DMAP; this was verified in experiments...

  20. Fluidic system for long-term in vitro culturing and monitoring of organotypic brain slices

    DEFF Research Database (Denmark)

    Bakmand, Tanya; Troels-Smith, Ane R.; Dimaki, Maria

    2015-01-01

    Brain slice preparations cultured in vitro have long been used as a simplified model for studying brain development, electrophysiology, neurodegeneration and neuroprotection. In this paper an open fluidic system developed for improved long term culturing of organotypic brain slices is presented....... The positive effect of continuous flow of growth medium, and thus stability of the glucose concentration and waste removal, is simulated and compared to the effect of stagnant medium that is most often used in tissue culturing. Furthermore, placement of the tissue slices in the developed device was studied...... by numerical simulations in order to optimize the nutrient distribution. The device was tested by culturing transverse hippocampal slices from 7 days old NMRI mice for a duration of 14 days. The slices were inspected visually and the slices cultured in the fluidic system appeared to have preserved...

  1. Flat slices in Minkowski space

    Science.gov (United States)

    Murchadha, Niall Ó.; Xie, Naqing

    2015-03-01

    Minkowski space, flat spacetime, with a distance measure in natural units of d{{s}2}=-d{{t}2}+d{{x}2}+d{{y}2}+d{{z}2}, or equivalently, with spacetime metric diag(-1, +1, +1, +1), is recognized as a fundamental arena for physics. The Poincaré group, the set of all rigid spacetime rotations and translations, is the symmetry group of Minkowski space. The action of this group preserves the form of the spacetime metric. Each t = constant slice of each preferred coordinate system is flat. We show that there are also nontrivial non-singular representations of Minkowski space with complete flat slices. If the embedding of the flat slices decays appropriately at infinity, the only flat slices are the standard ones. However, if we remove the decay condition, we find non-trivial flat slices with non-vanishing extrinsic curvature. We write out explicitly the coordinate transformation to a frame with such slices.

  2. TNTM85 and TNTM81 transports / storage flasks: An optimized solution for vitrified residues

    International Nuclear Information System (INIS)

    Sicard, D.; Verdier, A.; Dyck, P.

    2006-01-01

    By analyzing the evolution of burnup of spent fuel to be reprocessed, the high activity vitrified residues would not be transported in the existing flask designs. Therefore COGEMA LOGISTICS decided in the late nineties to develop a design with optimized capacity able to store and transport the most active and hottest canisters. The TN TM 85 flask shall permit in the near future in Germany the storage and the transport of the highest vitrified residues defining a thermal power of 56 kW. The challenge for the TN TM 85 flask design was that the geometry entry data were very restrictive and were combined with a fairly wide range set by COGEMA Specification 300AQ16 relative to vitrified residue canister. In addition, the cask had to fit as much as possible in the existing procedures for the TN TM 28 cask and TS 28 V cask, all along the logistics chain of loading, unloading, transport and maintenance. (authors)

  3. Prolonged life of human acute hippocampal slices from temporal lobe epilepsy surgery

    DEFF Research Database (Denmark)

    Wickham, J; Brödjegård, N G; Vighagen, R

    2018-01-01

    Resected hippocampal tissue from patients with drug-resistant epilepsy presents a unique possibility to test novel treatment strategies directly in target tissue. The post-resection time for testing and analysis however is normally limited. Acute tissue slices allow for electrophysiological...... granule whole-cell recordings, can be consistently induced in these slices, underlying the usefulness of this methodology for testing and/or validating novel treatment strategies for epilepsy....

  4. Information dossier. Return of vitrified wastes from France to Belgium; Dossier d'information. Retour de dechets vitrifies depuis la France vers la Belgique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-02-01

    Synatom, a daughter company of Electrabel and Tractebel, is in charge of the fuel management of Belgium nuclear power plants. Contracts were signed with Cogema (France) in the 70's for the reprocessing/recycling of spent fuels. The ultimate residual wastes are vitrified at Cogema-La Hague and sent back to Belgium by rail and road transports. This information dossier presents: the power production in Belgium, the management of the fuel cycle in Belgium (recycling, interim storage of spent fuels at Tihange and Doel sites, political choices, financing), the vitrification process (quality assurance, safety), the transport of vitrified wastes from France to Belgium (handling, packaging, TN 28 VT container, regulations, safety evaluation), interim storage, long-term disposal. (J.S.)

  5. Theoretical-experimental comparison of vitrified glass container behavior using the Castem system

    International Nuclear Information System (INIS)

    Moncouyoux, J.P.; Jamet, P.; Combescure, A.; Millard, A.

    1989-01-01

    This paper compares theoretical predictions of vitrified nuclear waste glass package collapse with experimental values in order to qualify the mathematical models describing canister deformation under external pressure loads. After briefly outlining the program and describing the experiments performed, the paper discusses the theoretical predictions based on the INCA code from the CEA's CASTEM system

  6. Using depleted uranium to shield vitrified high-level waste packages

    International Nuclear Information System (INIS)

    Yoshimura, H.R.; Gildea, P.D.; Bernard, E.A.

    1995-01-01

    The underlying report for this paper evaluates options for using depleted uranium as shielding materials for transport systems for disposal of vitrified high-level waste (VHLW). In addition, economic analyses are presented to compare costs associated with these options to costs, associated with existing and proposed storage, transport, and diposal capabilities. A more detailed evaluation is provided elsewhere. (Yoshimura et al. 1995.)

  7. In-straw cryoprotectant dilution of IVP bovine blastocysts vitrified in hand-pulled glass micropipettes.

    Science.gov (United States)

    Vieira, A D; Forell, F; Feltrin, C; Rodrigues, J L

    2007-06-01

    The aim of this study was to determine the influence of two ethylene glycol-based vitrification solutions on in vitro and in vivo survival after in-straw cryoprotectant dilution of vitrified in vitro-produced bovine embryos. Day-7 expanded blastocysts were selected according to diameter (> or = 180 microm) and osmotic characteristics and randomly assigned to one of three groups (i) VSa: vitrification in 40% EG+17.1% SUC+0.1% PVA; (ii) VSb: vitrification in 20% EG+20% DMSO; (iii) control: non-vitrified embryos. Vitrification was performed in hand-pulled glass micropipettes (GMP) and cryoprotectant dilution in 0.25 ml straws after warming in a plastic tube. Embryo viability was assessed by re-expansion and hatching rates after 72 h of IVC and by pregnancy rates after direct transfer of vitrified embryos. No differences in re-expansion rates were observed between vitrified groups after 24 h in culture (VSa=84.5%; VSb=94.8%). However, fewer VSa embryos (55.2%, Pstraw cryoprotectant dilution and direct embryo transfer.

  8. Safety of handling, storing and transportation of spent nuclear fuel and vitrified high-level wastes

    International Nuclear Information System (INIS)

    Ericsson, A.M.

    1977-11-01

    The safety of handling and transportation of spent fuel and vitrified high-level waste has been studied. Only the operations which are performed in Sweden are included. That is: - Transportation of spent fuel from the reactors to an independant spent fuel storage installation (ISFSI). - Temporary storage of spent fuel in the ISFSI. - Transportation of the spent fuel from the ISFSI to a foreign reprocessing plant. - Transportation of vitrified high-level waste to an interim storage facility. - Interim storage of vitrified high-level waste. - Handling of the vitrified high-level waste in a repository for ultimate disposal. For each stage in the handling sequence above the following items are given: - A brief technical description. - A description of precautionary measures considered in the design. - An analysis of the discharges of radioactive materials to the environment in normal operation. - An analysis of the discharges of radioactive materials due to postulated accidents. The dose to the public has been roughly and conservatively estimated for both normal and accident conditions. The expected rate of occurence are given for the accidents. The results show that above described handling sequence gives only a minor risk contribution to the public

  9. Surface storage of vitrified high-level radioactive waste in reinforced-concrete casks

    International Nuclear Information System (INIS)

    Beale, H.; George, M.W.; Robertson, T.J.M.

    1982-06-01

    The feasibility of storing canisters containing vitrified high level radioactive waste in reinforced concrete casks is examined. This preliminary study identifies the limitations and probable cost of such a store and leads to the conclusion that the concept is feasible. (author)

  10. Tissue

    Directory of Open Access Journals (Sweden)

    David Morrissey

    2012-01-01

    Full Text Available Purpose. In vivo gene therapy directed at tissues of mesenchymal origin could potentially augment healing. We aimed to assess the duration and magnitude of transene expression in vivo in mice and ex vivo in human tissues. Methods. Using bioluminescence imaging, plasmid and adenoviral vector-based transgene expression in murine quadriceps in vivo was examined. Temporal control was assessed using a doxycycline-inducible system. An ex vivo model was developed and optimised using murine tissue, and applied in ex vivo human tissue. Results. In vivo plasmid-based transgene expression did not silence in murine muscle, unlike in liver. Although maximum luciferase expression was higher in muscle with adenoviral delivery compared with plasmid, expression reduced over time. The inducible promoter cassette successfully regulated gene expression with maximum levels a factor of 11 greater than baseline. Expression was re-induced to a similar level on a temporal basis. Luciferase expression was readily detected ex vivo in human muscle and tendon. Conclusions. Plasmid constructs resulted in long-term in vivo gene expression in skeletal muscle, in a controllable fashion utilising an inducible promoter in combination with oral agents. Successful plasmid gene transfection in human ex vivo mesenchymal tissue was demonstrated for the first time.

  11. Thin slices and Sherlock Holmes

    African Journals Online (AJOL)

    based on very little information, and often in a matter of seconds. This is partly based on very narrow slices of our experience, and involves pattern recognition, as well as the memory banks of our senses. It is also partly a heuristic process whereby one rapidly discards ideas or notions, or promotes other hypotheses, as one.

  12. Preparation of positional renal slices for study of cell-specific toxicity.

    Science.gov (United States)

    Ruegg, C E; Gandolfi, A J; Nagle, R B; Krumdieck, C L; Brendel, K

    1987-04-01

    To reduce structural complexity, rabbit kidneys were sliced perpendicular to their cortical-papillary axis to isolate four distinct cell groupings. This positional orientation allows identification of each renal cell type based on its location within the slice. A mechanical slicer was used to make several precision-cut slices rapidly from an oriented cylindrical core of renal tissue, with minimal tissue trauma. Slices were then submerged under a gently circulating oxygenated media in a fritted glass support system that maintains viability (intracellular K+/DNA ratio) and structural integrity (histology) for at least 30 h. A high dose of mercuric chloride (10(-3) M) was used to demonstrate the structural and biochemical changes of intoxicated slices. This method provides a controlled subchronic in vitro system for the study of the individual cell types involved in cell-specific renal toxicities and may also be a useful tool for addressing other pharmacological and physiological research questions.

  13. Feasibility study on utilization of vitrified radioactive waste as radiation sources

    International Nuclear Information System (INIS)

    Makuuchi, Keizo; Yoshii, Fumio; Hyakutake, Kenichiro

    1995-01-01

    A feasibility study on utilization of vitrified high level radioactive waste (VW) as radiation source has been carried out. Natural rubber latex was radiation vulcanized with VW to demonstrate the feasibility. The dose rate was 0.1 kGy/hr. As a sensitizer, n-butyl acrylate was added. Negligible small activation of natural rubber (NR) latex by neutron from the VW was observed. The residual sensitizer in the irradiated latex and physical properties of film molded from the irradiated latex were the same level with the conventional radiation vulcanization of NR latex with γ-rays from Co-60. Surgical gloves and protective rubber gloves for radioactive contamination were produced from 20 litters of NR latex vulcanized with 2 VWs. The physical properties of both gloves were acceptable. These results suggested that vitrified high level waste can be used as an industrial radiation source. (author)

  14. Technology survey for real-time monitoring of plutonium in a vitrifier off-gas system

    International Nuclear Information System (INIS)

    Berg, J.M.; Veirs, D.K.

    1996-01-01

    We surveyed several promising measurement technologies for the real-time monitoring of plutonium in a vitrifier off-gas system. The vitrifier is being developed by Westinghouse Savannah River Corp. and will be used to demonstrate vitrification of plutonium dissolved in nitric acid for fissile material disposition. The risk of developing a criticality hazard in the off-gas processing equipment can be managed by using available measurement technologies. We identified several potential technologies and methods for detecting plutonium that are sensitive enough to detect the accumulation of a mass sufficient to form a criticality hazard. We recommend gross alpha-monitoring technologies as the most promising option for Westinghouse Savannah River Corp. to consider because that option appears to require the least additional development. We also recommend further consideration for several other technologies because they offer specific advantages and because gross alpha-monitoring could prove unsuitable when tested for this specific application

  15. Thermal test and analysis for transporting vitrified high-level radioactive wastes

    International Nuclear Information System (INIS)

    Yamakawa, H.; Gomi, Y.; Ozaki, S.; Kato, O.; Tamaki, H.

    1993-01-01

    As a part of the safety demonstration tests for transport casks of high level radioactive vitrified wastes, the thermal tests of the cask (left unattended at an ambient temperature of 38degC for a period of one week) were executed before and after the side free drop test (from height of 30 cm). This condition was set according to the prospect of the damage of contents (baskets, etc.) by the impact force at the drop test. It was shown that the cask temperatures at the representative parts, such as the vitrified wastes, the containment system, and the protection wire net, were lower than allowable values. From the result of measured temperatures it was considered that no damages and no large deformations could happen to the contents in this drop test. Thermal analysis was also done to establish the analysis model. (J.P.N.)

  16. Slices

    KAUST Repository

    McCrae, James; Singh, Karan; Mitra, Niloy J.

    2011-01-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours

  17. Metabolic changes in droplet vitrified semen of wild endangered Persian sturgeon Acipenser persicus (Borodin, 1997).

    Science.gov (United States)

    Abed-Elmdoust, Amirreza; Farahmand, Hamid; Mojazi-Amiri, Bagher; Rafiee, Gholamreza; Rahimi, Ruhollah

    2017-06-01

    Comparative quantitative metabolite profiling can be used for better understanding of cell functions and dysfunctions in particular circumstances such as sperm banking which is an important approach for cryopreservation of endangered species. Cryopreservation techniques have some deleterious effects on spermatozoa which put the obtained results in controversy. Therefore, in the present study, quantitative 1 H NMR (Nuclear Magnetic Resonance) based metabolite profiling was conducted to evaluate metabolite changes related to energetics and some other detected metabolites in vitrified semen of critically endangered wild Acipenser persicus. The semen was diluted with extenders containing 0, 5, 10, and 15 μM of fish antifreeze protein (AFP) type III as a cryoprotectant. Semen-extenders were vitrified and stored for two days. Based on post-thaw motility duration and motility percentage assessments, two treatments with 10 μM and 0 μM of AFP had the highest and the lowest motility percentages respectively and they were objected to 1 H NMR spectroscopy investigations in order to reveal the extremes of the metabolites dynamic range. Univariate (ANOVA) and multivariate (PCA) analysis of the resulting metabolic profiles indicated significant changes (P > 0.05) in metabolites. The level of some metabolites including acetate, adenine, creatine, creatine phosphate, lactate, betaine, sarcosine, β-alanine and trimethylamine N-oxide significantly decreased in vitrified semen while some others such as creatinine, guanidinoacetate, N, N-dimethylglycine, and glycine significantly increased. There were also significant differences between vitrified treatments in levels of creatine, creatine phosphate, creatinine, glucose, guanidinoacetate, lactate, N, N-dimethylglycine, and glycine, suggesting how fish AFP type III can be effective as a cryoprotectant. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Handling of spent nuclear fuel and final storage of vitrified high level reprocessing waste

    International Nuclear Information System (INIS)

    1978-01-01

    The report gives a general summary of the Swedish KBS-project on management and disposal of vitrified reprocessed waste. Its final aim is to demostrate that the means of processing and managing power reactor waste in an absolutely safe way, as stipulated in the Swedish so called Conditions Act, already exist. Chapters on Storage facility for spent fuel, Intermidiate storage of reprocessed waste, Geology, Final repository, Transportation, Protection, and Siting. (L.E.)

  19. Handling of spent nuclear fuel and final storage of vitrified high level reprocessing waste

    International Nuclear Information System (INIS)

    1978-01-01

    A summary of the planning of transportation and plant design in the Swedish KBS project on management and disposal reprocessed radioactive waste. It describes a transportation system, a central storage facility for used fuel elements, a plant for intermediate storage and encapsulation and a final repository for the vitrified waste. Accounts are given for the reprocessing and vitrification. The safety of the entire system is discussed

  20. CHARACTERIZATION OF VITRIFIED SAVANNAH RIVER SITE SB4 WASTE SURROGATE PRODUCED IN COLD CRUCIBLE

    International Nuclear Information System (INIS)

    Marra, J

    2008-01-01

    Savannah River Site (SRS) sludge batch 4 (SB4) waste surrogate with high aluminum and iron content was vitrified with commercially available Frit 503-R4 (8 wt.% Li 2 O, 16 wt.% B2O3, 76 wt.% SiO 2 ) by cold crucible inductive melting using lab- (56 mm inner diameter), bench- (236 mm) and large-scale (418 mm) cold crucible. The waste loading ranged between 40 and 60 wt.%. The vitrified products obtained in the lab-scale cold crucible were nearly amorphous with traces of unreacted quartz in the product with 40 wt.% waste loading and traces of spinel phase in the product with 50 wt.% waste loading. The glassy products obtained in the bench-scale cold crucible are composed of major vitreous and minor iron-rich spinel phase whose content at ∼60 wt.% waste loading may achieve ∼10 vol.%. The vitrified waste obtained in the large-scale cold crucible was also composed of major vitreous and minor spinel structure phases. No nepheline phase has been found. Average degree of crystallinity was estimated to be ∼12 vol.%. Anionic motif of the glass network is built from rather short metasilicate chains and boron-oxygen constituent based on boron-oxygen triangular units

  1. Stabilization of vitrified wastes: Task 4. Topical report, October 1994--September 1995

    International Nuclear Information System (INIS)

    Nowok, J.W.; Pflughoeft-Hassett, D.F.; Hassett, D.J.; Hurley, J.P.

    1995-09-01

    The goal of this task was to work with private industry to refine existing vitrification processes to produce a more stable vitrified product. The initial objectives were to (1) demonstrate a waste vitrification procedure for enhanced stabilization of waste materials and (2) develop a testing protocol to understand the long-term leaching behavior of the stabilized waste form. The testing protocol was expected to be based on a leaching procedure called the synthetic groundwater leaching procedure (SGLP). This task will contribute to the US DOE's identified technical needs in waste characterization, low-level mixed-waste processing, disposition technology, and improved waste forms. The proposed work was to proceed over 4 years in the following steps: literature surveys to aid in the selection and characterization of test mixtures for vitrification, characterization of optimized vitrified test wastes using advanced leaching protocols, and refinement and demonstration of vitrification methods leading to commercialization. For this year, literature surveys were completed, and computer modeling was performed to determine the feasibility of removing heavy metals from a waste during vitrification, thereby reducing the hazardous nature of the vitrified material and possibly producing a commercial metal concentrate. This report describes the following four subtasks: survey of vitrification technologies; survey of cleanup sites; selection and characterization of test mixtures for vitrification and crystallization; and selection of crystallization methods based on thermochemistry modeling

  2. Neonatal health including congenital malformation risk of 1072 children born after vitrified embryo transfer.

    Science.gov (United States)

    Belva, F; Bonduelle, M; Roelants, M; Verheyen, G; Van Landuyt, L

    2016-07-01

    Does vitrification of Day 3 and Day 5 embryos adversely affect birth outcomes of singletons and twins in comparison with peers born after fresh embryo transfer? Neonatal health parameters, including the prevalence of congenital malformations, in singletons and twins born after embryo vitrification are similar to or slightly better than after fresh embryo transfer. Although vitrification, rather than slow-freezing, of embryos is routine practice nowadays, convincing evidence regarding the safety for the offspring is sparse. Literature data comprise results from mostly small-sized studies or studies including only Day 3 or only Day 5 vitrified embryo transfers. Overall, better or comparable perinatal outcomes, in terms of higher birthweight and lower risk for small-for-gestational age or for low birthweight, have been reported for singletons born after vitrified embryo transfer compared with fresh embryo transfer. According to the single available study with sufficient sample size, the congenital malformation rate was found to be comparable after vitrified and fresh embryo transfers. Data were collected from 960 cycles after transfer of embryos vitrified on Day 3 (n = 457) or Day 5 (n = 503) and from 1644 cycles after fresh embryo transfer on Day 3 (n = 853) or Day 5 (n = 791), performed between 2008 and 2013 at the Centre for Reproductive Medicine of the university hospital UZ Brussel. Outcome measures were neonatal health in terms of birthweight, small-for-gestational age, prematurity rate, perinatal death and major/minor/total malformation rate. Perinatal health parameters of 11 stillborns and 1061 live borns (827 singletons and 234 twins) in the vitrified group and of 28 stillborns and 1838 live borns (1374 singletons and 464 twins) in the fresh embryo group are reported. Within 3 months after birth, children in the two study groups were assessed clinically with special attention to congenital malformations by a paediatrician blinded to the type of embryo

  3. A novel lung slice system with compromised antioxidant defenses

    Energy Technology Data Exchange (ETDEWEB)

    Hardwick, S.J.; Adam, A.; Cohen, G.M. (Univ. of London (England)); Smith, L.L. (Imperial Chemical Industries PLC, Cheshire (England))

    1990-04-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 {mu}M) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP{sup +}, and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of {sup 14}CO{sub 2} from D-({sup 14}C(U))-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone.

  4. A novel lung slice system with compromised antioxidant defenses

    International Nuclear Information System (INIS)

    Hardwick, S.J.; Adam, A.; Cohen, G.M.; Smith, L.L.

    1990-01-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 μM) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP + , and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of 14 CO 2 from D-[ 14 C(U)]-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone

  5. Sugar uptake and starch biosynthesis by slices of developing maize endosperm

    International Nuclear Information System (INIS)

    Felker, F.C.; Liu, Kangchien; Shannon, J.C.

    1990-01-01

    14 C-Sugar uptake and incorporation into starch by slices of developing maize (Zea mays L.) endosperm were examined and compared with sugar uptake by maize endosperm-derived suspension cultures. Rates of sucrose, fructose, and D- and L-glucose uptake by slices were similar, whereas uptake rates for these sugars differed greatly in suspension cultures. Concentration dependence of sucrose, fructose, and D-glucose uptake was biphasic (consisting of linear plus saturable components) with suspension cultures but linear with slices. These and other differences suggest that endosperm slices are freely permeable to sugars. After diffusion into the slices, sugars were metabolized and incorporated into starch. Starch synthesis, but not sugar accumulation, was greatly reduced by 2.5 millimolar p-chloromercuribenzenesulfonic acid and 0.1 millimolar carbonyl cyanide m-chlorophenylhydrazone. Starch synthesis was dependent on kernel age and incubation temperature, but not on external pH (5 through 8). Competing sugars generally did not affect the distribution of 14 C among the soluble sugars extracted from endosperm slices incubated in 14 C-sugars. Competing hexoses reduced the incorporation of 14 C into starch, but competing sucrose did not, suggesting that sucrose is not a necessary intermediate in starch biosynthesis. The bidirectional permeability of endosperm slices to sugars makes the characterization of sugar transport into endosperm slices impossible, however the model system is useful for experiments dealing with starch biosynthesis which occurs in the metabolically active tissue

  6. Cytotoxicity of retinoic acid, menadione and aflatoxin B1 in rat liver slices using netwell inserts as a culture system

    NARCIS (Netherlands)

    Leeman, W.R.; Gevel, I.A. van de; Rutten, A.A.J.J.L.

    1995-01-01

    Precision-cut rat liver slices were used to develop a new dynamic incubation system in which histomorphology and measurement of the release of lactate dehydrogenase (LDH) and the conversion of MTT were applied to evaluate cytotoxicity. Liver slices, precision-cut using a Krumdieck tissue slicer,

  7. Radiation sterilization and identification of gizzard slices

    International Nuclear Information System (INIS)

    Zhu, S.; Fu, C.; Jiang, W.; Yao, D.; Zhao, K.; Zhang, Y.

    1998-01-01

    An orthogonal test of 4 factors of radiation dose, storage temperature, storage time, and sanitation of cutting places was carried out to optimize the conditions for disinfection of gizzard slices. In the optimized condition, both the sanitary quality and the shelf-life of gizzard slices were improved. To identify irradiated gizzard slices, the sensory change, and the levels of water-soluble nitrogen, amino acid, total volatile basic nitrogen, peroxide value, vitamin C consumption and KMnO 4 consumption were determinated. No significant change was observed except for the color which was light brown on the surface of irradiated slices

  8. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  9. Vitrified medical wastes bottom ash in cement clinkerization. Microstructural, hydration and leaching characteristics.

    Science.gov (United States)

    Papamarkou, S; Christopoulos, D; Tsakiridis, P E; Bartzas, G; Tsakalakis, K

    2018-04-19

    The present investigation focuses on the utilization of medical wastes incineration bottom ash (MBA), vitrified with soda lime recycled glass (SLRG), as an alternative raw material in cement clinkerization. Bottom ash is recovered from the bottom of the medical wastes incineration chamber, after being cooled down through quenching. It corresponds to 10-15 wt% of the initial medical wastes weight and since it has been classified in the category of hazardous wastes, its safe management has become a major environmental concern worldwide. MBA glasses of various syntheses were initially obtained during the MBA vitrification simultaneously with various amounts of silica scrap (20, 25 and 30 wt% correspondingly). The produced MBA glasses were in turn used for the production of Portland cement clinker, after sintering at 1400 °C, thus substituting traditional raw materials. Both evaluation of vitrification and sintering products was carried out by chemical and mineralogical analyses along with microstructure examination. The final cements were prepared by clinkers co-grinding in a laboratory ball mill with appropriate amounts of gypsum (≈5.0 wt%) and the evaluation of their quality was carried out by determining setting times, standard consistency, expansibility and compressive strength at 2, 7, 28 and 90 days. Finally, the leaching behaviour of the vitrified MBA and hydrated cements, together with the corresponding of the "as received" MBA, was further examined using the standard leaching tests of the Toxicity Characteristic Leaching Procedure (TCLP) and the EN 12457-2. According to the obtained results, the quality of the produced cement clinkers was not affected by the addition of the vitrified MBA in the raw meal, with the trace elements detected in all leachates measured well below the corresponding regulatory limits. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. The physiology of rodent beta-cells in pancreas slices.

    Science.gov (United States)

    Rupnik, M

    2009-01-01

    Beta-cells in pancreatic islets form complex syncytia. Sufficient cell-to-cell electrical coupling seems to ensure coordinated depolarization pattern and insulin release that can be further modulated by rich innervation. The complex structure and coordinated action develop after birth during fast proliferation of the endocrine tissue. These emergent properties can be lost due to various reasons later in life and can lead to glucose intolerance and diabetes mellitus. Pancreas slice is a novel method of choice to study the physiology of beta-cells still embedded in their normal cellulo-social context. I present major advantages, list drawbacks and provide an overview on recent advances in our understanding of the physiology of beta-cells using the pancreas slice approach.

  11. A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

    Science.gov (United States)

    Mitra, Jhimli; Srikantha, Abhilash; Sidibé, Désiré; Martí, Robert; Oliver, Arnau; Lladó, Xavier; Ghose, Soumya; Vilanova, Joan C.; Comet, Josep; Meriaudeau, Fabrice

    2012-02-01

    This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to perform an analysis based on shape and information theory to reach close enough to the actual MR slice as validated by experts. The Bhattacharyya distance is used to find point correspondences between shape-context representations of the prostate contours. Thereafter, Chi-square distance is used to find out those MR slices where the prostates closely match with that of the TRUS slice. Normalized Mutual Information (NMI) values of the TRUS slice with each of the axial MR slices are computed after rigid alignment and consecutively a strategic elimination based on a set of rules between the Chi-square distances and the NMI leads to the required MR slice. We validated our method for TRUS axial slices of 15 patients, of which 11 results matched at least one experts validation and the remaining 4 are at most one slice away from the expert validations.

  12. Integrating interface slicing into software engineering processes

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    Interface slicing is a tool which was developed to facilitate software engineering. As previously presented, it was described in terms of its techniques and mechanisms. The integration of interface slicing into specific software engineering activities is considered by discussing a number of potential applications of interface slicing. The applications discussed specifically address the problems, issues, or concerns raised in a previous project. Because a complete interface slicer is still under development, these applications must be phrased in future tenses. Nonetheless, the interface slicing techniques which were presented can be implemented using current compiler and static analysis technology. Whether implemented as a standalone tool or as a module in an integrated development or reverse engineering environment, they require analysis no more complex than that required for current system development environments. By contrast, conventional slicing is a methodology which, while showing much promise and intuitive appeal, has yet to be fully implemented in a production language environment despite 12 years of development.

  13. Measurement of slice sensitivity profile for a 64-slice spiral CT system

    International Nuclear Information System (INIS)

    Liu Chuanya; Qin Weichang; Wang Wei; Lu Chuanyou

    2006-01-01

    Objective: To measure and evaluate slice sensitivity profile (SSP) and the full width at half-maximum(FWHM) for a 64-slice spiral CT system. Methods: Using the same CT technique and body mode as those used for clinical CT, delta phantom was scanned with Somatom Sensation 64-slice spiral CT. SSPs and FWHM were measured both with reconstruction slice width of 0.6 mm at pitch=0.50, 0.75, 1.00, 1.25, 1.50 and with reconstruction slice width of 0.6, 1.0, 1.5 mm at pitch=1 respectively. Results: For normal slice width of 0. 6 mm, the measured FWHM, i.e. effective slice width, is 0.67, 0.67, 0.66, 0.69, 0.69 mm at different pitch. All the measured FWHM deviate less than 0.1 mm from the nominal slice width. The measured SSPs are symmetrical, bell-shaped curves without far-reaching tails, and show only slight variations as a function of the spiral pitch. When reconstruction slice width increase, relative SSP become wider. Conclusions: The variation of pitch hardly has effect all on SSP, effective slice width, and z-direction spatial resolution for Sensation 64-slice spiral CT system, which is helpful to optimize CT scanning protocol. (authors)

  14. Qualification of a Vitrified High Level Waste Product to Support Used Nuclear Fuel Recycling in the US

    International Nuclear Information System (INIS)

    Murray, P.; Bailly, F.; Strachan, D.; Senentz, G.; Veyer, C.

    2009-01-01

    As part of the Department of Energy (DOE) Global Nuclear Energy Partnership (GNEP), AREVA formed the International Nuclear Recycling Alliance (INRA) consisting of recognized world-leading companies in the area of used nuclear fuel (UNF) recycling,. The INRA team, consisting of AREVA, Mitsubishi Heavy Industries (MHI), Japan Nuclear Fuel Ltd (JNFL), Batelle Memorial Institute (BMI), URS Washington Division and Babcock and Wilcox (B and W), prepared a pre-conceptual design for an upgradable engineering-scale recycling plant with a nominal through put of 800 tHM/y. The pre-conceptual design of this leading-edge facility was based upon the extensive experience of the INRA team in recycling plant design and real world 'lessons learned' from actually building, commissioning, and operating recycling facilities in both France and Japan. The conceptual flowsheet, based upon the COEX TM separations process, separates the useful products for recycling into new fuel and sentences all the remaining fission products and minor actinides (MA) to the high level waste, (HLW) for vitrification. The proposed vitrified waste product will be similar to that currently produced in recycling plants in France. This wasteform has been qualified in France by conducting extensive studies and demonstrations. In the US, the qualification of vitrified glass products has been conducted by the US National Laboratories for the Defence Waste Processing Facility (DWPF), the West Valley Demonstration Plant (WVDP), and the Waste Treatment Plant (WTP). The vitrified waste product produced by recycling is sufficiently different from these current waste forms to warrant additional trials and studies. In this paper we review the differences in the vitrified waste forms previously qualified in the US with that produced from recycling of UNF in France. The lessons learned from qualifying a vitrified waste form in Europe is compared to the current US process for vitrified waste qualification including waste

  15. State-of-the-art review of quality assurance techniques for vitrified high level waste

    International Nuclear Information System (INIS)

    Miller, P.L.H.

    1984-07-01

    Quality assurance is required for certain chemical and physical properties of both the molten glass pour and the solidified glass within the stainless steel container. It is also required to monitor the physical condition of the container lid weld. A review is presented of techniques which are used or which might be adapted for use in the quality assurance of vitrified high level waste. For the most part only non-intrusive methods have been considered, however, some techniques which are not strictly non-intrusive have been reviewed where a non-intrusive technique has not been identified or where there are other advantages associated with the particular technique. In order to identify suitable candidate techniques reference has been made to an extensive literature survey and experts in the fields of nuclear waste technology, glass technology, non-destructive testing, chemical analysis and remote analysis have been contacted. The opinions of manufacturers and users of specific techniques have also been sought. A summary is also given of those techniques which can most readily be applied to the problem of quality assurance for vitrified waste as well as recommendations for further research into techniques which might be adapted to suit this application. (author)

  16. In vitro production of buffalo embryos from stepwise vitrified immature oocytes.

    Science.gov (United States)

    Abd-Allah, Saber Mohammed

    2009-01-01

    This study was conducted to produce buffalo embryos in vitro from stepwise vitrified immature oocytes. Cumulus oocyte complexes (COCs) were obtained from the ovaries of slaughtered buffalo and were collected from the local abattoir. Selected COCs were exposed to a vitrification solution consisting of 40% ethylene glycol (EG) plus 0.3 M trehalose and 20% polyvinyl pyrrolidone (PVP) for 1 min and loaded in 0.25 ml plastic mini-straws containing 100 microl of 10% sucrose. The loaded cryostraws were cryopreserved by stepwise vitrification and were stored in liquid nitrogen for 4 to 6 months. Data analysis revealed a high percentage of post-thawing morphologically normal immature oocytes (80.7%) with a low percentage of damaged oocytes. There were no significant differences in the maturation (82.1%), cleavage (47.6%) and buffalo embryo development (15.4%) produced by the stepwise vitrified immature oocytes in comparison to the three observations in fresh oocytes (88.3%, 50.4% and 19.4%, respectively, p<0.05).

  17. Alteration of medieval stained-glasses. Contribution to the long-term behaviour of vitrified wastes

    International Nuclear Information System (INIS)

    Sterpenich, J.

    1998-01-01

    In this work, the behaviour of glasses during alteration have been studied in two different ways: 1)study of the alteration of medieval stained-glasses 2)experimental leaching of modelled glasses. Medieval stained-glasses have a silico-calcic and alkaline composition. It appears three different alteration modes for these glasses: 1)by condensation waters 2)by atmospheric agents 3)by porosity waters and humic acids. A chemical study of the altered areas has allowed to understand the alteration behaviour of a lot of elements: in particular transition elements, heavy metals and some rare earths. On the other hand, two vitrified wastes and a glass having the same composition of the potassic medieval stained-glasses have been leached in a static mode (pH=1 to 10, T=20 to 80 degrees Celsius, T=12 hours to 6 months). These experiments have revealed that the alteration mechanisms depend on the pH of the solution and on the chemical composition of the glass. An increasing durability of glasses in terms of the global polymerization degree has been revealed too. At last, the behaviours of glasses during alteration, observed with natural and experimental conditions, show that it is necessary to study natural analogous for predicting the long-term behaviour of vitrified wastes. (O.M.)

  18. Underground disposal of vitrified high level radioactive waste: a review of research and development

    International Nuclear Information System (INIS)

    1982-11-01

    A review has been undertaken of the worldwide status of research and development related to the geological disposal of vitrified high level radioactive waste. The nature and quantities of vitrified high level waste that will arise from nuclear power generation in the UK have been estimated and considered. The safety case for establishing a geological repository would have to be based on predictive models, which could adequately represent the interactions and effects of a wide range of gradual processes and possible sudden events. No detailed repository design has yet been published, but the configuration currently favoured, in the UK and in most other countries, comprises a small number of vertical shafts, from which a network of horizontal tunnels would be excavated. Waste packages would be placed in holes drilled in the floors of the tunnels. The excavation of such a repository in hard crystalline rock, in a thick homogeneous formation of rock salt, or in the less plastic argillaceous formations, appears to be within the scope of present technology. Rock types available in the UK, which are likely to prove suitable for the accommodation of a repository, have been identified. The strategies and programmes for high level waste disposal in other countries have been reviewed. (U.K.)

  19. Leaching of vitrified high-level-active-waste in a near reality simulated repository system

    International Nuclear Information System (INIS)

    Froeschen, W.; Wolf, G.K.

    1987-01-01

    In the FRG it is planned to vitrify the high level waste from spent fuel reprocessing and to dispose of in a salt-mine. If water penetrates into the repository a highly corrosive brine (Q-brine) will be formed and radioactive material may be leached from the glasses and transported to human environment. The corrosion system of brine, corroded steel containers of the vitrified waste, and waste-glasses was investigated under near reality conditions. Experiments in hydrothermal environment were carried out including gamma radiation of the waste-glasses and ceramic In Can Lining between glasses and metallic containments. Screening experiments by application of external cobalt-gamma-radiation showed no principal changes in leaching behaviour of simulate glasses compared to leaching without radiation. Radiation effects result in pH changes mainly which are diminished by buffer capacity of Q-brine. Lining of steel containments with ceramic fleece does not reduce leaching but retards solution of Mo and Sr into brine. Decreasing of elements Sr, Cs and Mo in the near surface area of the glass and increasing of Zr and Ti has been found to be enhanced considerably in presence of canister corrosion products in Q-brine as well as in NaCl-leaching solution. (orig.) With 13 refs., 22 figs [de

  20. In vitro production of buffalo embryos from stepwise vitrified immature oocytes

    Directory of Open Access Journals (Sweden)

    Saber Mohammed Abd-Allah

    2009-09-01

    Full Text Available This study was conducted to produce buffalo embryos in vitro from stepwise vitrified immature oocytes. Cumulus oocyte complexes (COCs were obtained from the ovaries of slaughtered buffalo and were collected from the local abattoir. Selected COCs were exposed to a vitrification solution consisting of 40% ethylene glycol (EG plus 0.3 M trehalose and 20% polyvinyl pyrrolidone (PVP for 1 min and loaded in 0.25 ml plastic mini-straws containing 100 µl of 10% sucrose. The loaded cryostraws were cryopreserved by stepwise vitrification and were stored in liquid nitrogen for 4 to 6 months. Data analysis revealed a high percentage of post-thawing morphologically normal immature oocytes (80.7% with a low percentage of damaged oocytes. There were no significant differences in the maturation (82.1%, cleavage (47.6% and buffalo embryo development (15.4% produced by the stepwise vitrified immature oocytes in comparison to the three observations in fresh oocytes (88.3%, 50.4% and 19.4%, respectively, p<0.05.

  1. Effect of Nanoparticles on the Survival and Development of Vitrified Porcine GV Oocytes.

    Science.gov (United States)

    Li, W J; Zhou, X L; Liu, B L; Dai, J J; Song, P; Teng, Y

    BACKGROUND: Some mammalian oocytes have been successfully cryopreserved by vitrification. However, the survival and developmental rate of vitrified oocytes is still low. The incorporation of nanoparticles into cryoprotectant (CPA) may improve the efficiency of vitrification by changing the properties of solutions. The toxicity of different concentrations of hydroxy apatite (HA), silica dioxide (SO 2 ), aluminum oxide (Al 2 O 3 ) and titanium dioxide (TiO 2 ) nanoparticles (20 nm in diameter) to oocytes was tested and the toxicity threshold value of each nanoparticle was determined. Porcine GV oocytes were vitrified in optimized nano-CPA, and effects of diameter and concentration of nanoparticles on the survival rate and developmental rate of porcine GV oocytes were compared. HA nanoparticles have demonstrated the least toxicity among four nanoparticles and the developmental rate of GV-stage porcine oocytes was 100% when its concentration was lower than 0.5%. By adding 0.1% HA into VS, the developmental rate of GV-stage porcine oocytes (22%) was significantly higher than other groups. The effect of vitrification in nano-CPA on oocytes was related to the concentration of HA nanoparticles rather than their size. By adding 0.05% HA nanoparticles (60nm in diameter), the developmental rate increased dramatically from 14.7% to 30.4%. Nano-cryopreservation offers a new way to improve the effect of survival and development of oocytes, but the limitation of this technology shall not be ignored.

  2. Lessons learned in demonstration projects regarding operational safety during final disposal of vitrified waste and spent fuel

    International Nuclear Information System (INIS)

    Filbert, Wolfgang; Herold, Philipp

    2015-01-01

    The paper summarizes the lessons learned in demonstration projects regarding operational safety during the final disposal of vitrified waste and spent fuel. The three demonstration projects for the direct disposal of vitrified waste and spent fuel are described. The first two demonstration projects concern the shaft transport of heavy payloads of up to 85 t and the emplacement operations in the mine. The third demonstration project concerns the borehole emplacement operation. Finally, open issues for the next steps up to licensing of the emplacement and disposal systems are summarized.

  3. Organotypic hippocampal slice cultures for studies of brain damage, neuroprotection and neurorepair

    DEFF Research Database (Denmark)

    Noraberg, Jens; Poulsen, Frantz Rom; Blaabjerg, Morten

    2005-01-01

    Slices of developing brain tissue can be grown for several weeks as so-called organotypic slice cultures. Here we summarize and review studies using hippocampal slice cultures to investigate mechanisms and treatment strategies for the neurodegenerative disorders like stroke (cerebral ischemia......), Alzheimer's disease (AD) and epilepsia. Studies of non-excitotoxic neurotoxic compounds and the experimental use of slice cultures in studies of HIV neurotoxicity, traumatic brain injury (TBI) and neurogenesis are included. For cerebral ischemia, experimental models with oxygen-glucose deprivation (OGD......) and exposure to glutamate receptor agonists (excitotoxins) are reviewed. For epilepsia, focus is on induction of seizures with effects on neuronal loss, axonal sprouting and neurogenesis. For Alzheimer's disease, the review centers on the use of beta-amyloid (Abeta) in different models, while the section...

  4. Precision cut lung slices as an efficient tool for in vitro lung physio-pharmacotoxicology studies.

    Science.gov (United States)

    Morin, Jean-Paul; Baste, Jean-Marc; Gay, Arnaud; Crochemore, Clément; Corbière, Cécile; Monteil, Christelle

    2013-01-01

    1.We review the specific approaches for lung tissue slices preparation and incubation systems and the research application fields in which lung slices proved to be a very efficient alternative to animal experimentation for biomechanical, physiological, pharmacological and toxicological approaches. 2.Focus is made on air-liquid interface dynamic organ culture systems that allow direct tissue exposure to complex aerosol and that best mimic in vivo lung tissue physiology. 3.A compilation of research applications in the fields of vascular and airway reactivity, mucociliary transport, polyamine transport, xenobiotic biotransformation, chemicals toxicology and complex aerosols supports the concept that precision cut lung slices are a very efficient tool maintaining highly differentiated functions similar to in vivo lung organ when kept under dynamic organ culture. They also have been successfully used for lung gene transfer efficiency assessment, for lung viral infection efficiency assessment, for studies of tissue preservation media and tissue post-conditioning to optimize lung tissue viability before grafting. 4.Taken all together, the reviewed studies point to a great interest for precision cut lung slices as an efficient and valuable alternative to in vivo lung organ experimentation.

  5. Piglets produced by transfer of vitrified porcine embryos after stepwise dilution of cryoprotectants.

    Science.gov (United States)

    Kobayashi, S; Takei, M; Kano, M; Tomita, M; Leibo, S P

    1998-02-01

    A total of 498 porcine embryos at various stages of development collected from superovulated gilts was used to investigate cryopreservation. First, blastocysts (BL), expanded blastocysts (ExB), and hatched blastocysts (HB) were used to determine the effect of exposure to concentrated solutions of ethylene glycol as cryoprotective additives (CPAs) on embryo survival. Then, survival of other embryos after vitrification by rapid cooling was determined. Based on their development after 48 h in culture, embryos were not injured by being exposed to 2.0 M ethylene glycol (EG) for 15 min or to 2.0 M EG for 5 min and then to a solution of 8.0 M EG in 7% polyvinylpyrrolidone (PVP) for 1 min. The CPAs were removed from the embryos by diluting them with 1.7 M galactose. To vitrify the embryos, they were exposed to 2.0 M EG for 5 min and then were pipetted directly into short columns of 8.0 M EG-PVP contained within (1.25-ml plastic straws and separated from long columns of 1.7 M galactose by an air bubble. The straws were plunged directly into LN2. After the straws were warmed rapidly in a 25 degrees C water bath, the embryos were immediately mixed with galactose within the straws by shaking them vigorously to mix the contents. In sequential experiments, three methods were used to dilute the CPA solutions. Method 1: Embryos in the EG-PVP-galactose mixture were expelled from the straws and rinsed and cultured in modified CZB medium (mCZB). Method II: Embryos in the mixture were placed briefly into 1.5 M EG and then rinsed and cultured in mCZB. Method III: Embryos in the mixture were rinsed in 1.0 M EG and then in 0.5 M EG and finally rinsed with mCZB and cultured. After 48 h in culture, the respective percentages of survival of embryos vitrified as BL, ExB, or HB were: Method I, 21, 32, and 13%; Method II, 9, 40, and 24%; Method III, 35, 85, and 71%. Of 20 additional ExB vitrified embryos diluted by Method III and transferred into a recipient, four developed into live piglets

  6. Synchrotron radiation XRF microprobe study of human bone tumor slice

    International Nuclear Information System (INIS)

    Huang Yuying; Zhao Limin; Wang Zhouguang; Shao Hanru; Li Guangcheng; Wu Yingrong; He Wei; Lu Jianxin; He Rongguo

    1999-01-01

    The experimental apparatus of X-ray fluorescence (XRF) microprobe analysis at Beijing Synchrotron Radiation Facility (BSRF) is described. Using the bovine liver as the standard reference, the minimum detection limit (MDL) of trace element was measured to determine the capability of biological sample analysis by synchrotron radiation XRF microprobe. The relative change of the content of the major or trace element in the normal and tumor part of human bone tissue slice was investigated. The experimental result relation to the clinical medicine was also discussed. (author)

  7. Outline and handling manual of experimental data time slice monitoring software 'SLICE'

    International Nuclear Information System (INIS)

    Shirai, Hiroshi; Hirayama, Toshio; Shimizu, Katsuhiro; Tani, Keiji; Azumi, Masafumi; Hirai, Ken-ichiro; Konno, Satoshi; Takase, Keizou.

    1993-02-01

    We have developed a software 'SLICE' which maps various kinds of plasma experimental data measured at the different geometrical position of JT-60U and JFT-2M onto the equilibrium magnetic configuration and treats them as a function of volume averaged minor radius ρ. Experimental data can be handled uniformly by using 'SLICE'. Plenty of commands of 'SLICE' make it easy to process the mapped data. The experimental data measured as line integrated values are also transformed by Abel inversion. The mapped data are fitted to a functional form and saved to the database 'MAPDB'. 'SLICE' can read the data from 'MAPDB' and re-display and transform them. Still more 'SLICE' creates run data of orbit following Monte-Carlo code 'OFMC' and tokamak predictive and interpretation code system 'TOPICS'. This report summarizes an outline and the usage of 'SLICE'. (author)

  8. Study on improvement in reliability of inventory assessment in vitrified waste for long-term safety of geological disposal

    International Nuclear Information System (INIS)

    Ishikawa, Masumi; Kaneko, Satoru; Kitayama, Kazumi; Ishiguro, Katsuhiko; Ueda, Hiroyoshi; Wakasugi, Keiichiro; Shinohara, Nobuo; Okumura, Keisuke; Chino, Masamichi; Moriya, Noriyasu

    2009-01-01

    Since quality control issues for vitrified waste are defined mainly with the focus on the transport and interim storage of the waste rather than the long-term safety of geological disposal, they do not cover inventories of long-lived nuclides that are of most interest in the safety assessment of geological disposal. Therefore, we suggest a flow chart for the assessment of inventories of long-lived nuclides in the vitrified waste focusing on the measured values. This includes an indirect assessment with indicative nuclides that have been already measured in the returned vitrified wastes from abroad. In order to apply this flow chart for commercial operation, its applicability should be examined for cases with a variation in burn-up history and with an uncertainty associated with carry-over fraction at reprocessing. We started an R and D program to examine the applicability as well as to improve the reliability of the nuclide generation/decay code and the nuclear data library using liquid waste from spent fuel with a clear irradiation history. To solve the issue of quality control for vitrified waste, a comprehensive study is needed in aspects not only of geological disposal field but also of operation of a nuclear power plant, reprocessing of spent fuel and vitrification of liquid waste. This study is a pioneering study conducted to integrate them. (author)

  9. A brain slice bath for physiology and compound microscopy, with dual-sided perifusion.

    Science.gov (United States)

    Heyward, P M

    2010-12-01

    Contemporary in vitro brain slice studies can employ compound microscopes to identify individual neurons or their processes for physiological recording or imaging. This requires that the bath used to maintain the tissue fits within the working distances of a water-dipping objective and microscope condenser. A common means of achieving this is to maintain thin tissue slices on the glass floor of a recording bath, exposing only one surface of the tissue to oxygenated bathing medium. Emerging evidence suggests that physiology can be compromised by this approach. Flowing medium past both sides of submerged brain slices is optimal, but recording baths utilizing this principle are not readily available for use on compound microscopes. This paper describes a tissue bath designed specifically for microscopy and physiological recording, in which temperature-controlled medium flows past both sides of the slices. A particular feature of this design is the use of concentric mesh rings to support and transport the live tissue without mechanical disturbance. The design is also easily adapted for use with thin acute slices, cultured slices, and acutely dispersed or cultured cells maintained either on cover slips or placed directly on the floor of the bath. The low profile of the bath provides a low angle of approach for electrodes, and allows use of standard condensers, nosepieces and water-dipping objective lenses. If visualization of individual neurons is not required, the bath can be mounted on a simple stand and used with a dissecting microscope. Heating is integral to the bath, and any temperature controller capable of driving a resistive load can be used. The bath is robust, readily constructed and requires minimal maintenance. Full construction and operation details are given. © 2010 The Author Journal of Microscopy © 2010 The Royal Microscopical Society.

  10. Statistical process control: An approach to quality assurance in the production of vitrified nuclear waste

    International Nuclear Information System (INIS)

    Pulsipher, B.A.; Kuhn, W.L.

    1987-01-01

    Current planning for liquid high-level nuclear wastes existing in the United States includes processing in a liquid-fed ceramic melter to incorporate it into a high-quality glass, and placement in a deep geologic repository. The nuclear waste vitrification process requires assurance of a quality product with little or no final inspection. Statistical process control (SPC) is a quantitative approach to one quality assurance aspect of vitrified nuclear waste. This method for monitoring and controlling a process in the presence of uncertainties provides a statistical basis for decisions concerning product quality improvement. Statistical process control is shown to be a feasible and beneficial tool to help the waste glass producers demonstrate that the vitrification process can be controlled sufficiently to produce an acceptable product. This quantitative aspect of quality assurance could be an effective means of establishing confidence in the claims to a quality product

  11. Statistical process control: An approach to quality assurance in the production of vitrified nuclear waste

    International Nuclear Information System (INIS)

    Pulsipher, B.A.; Kuhn, W.L.

    1987-02-01

    Current planning for liquid high-level nuclear wastes existing in the US includes processing in a liquid-fed ceramic melter to incorporate it into a high-quality glass, and placement in a deep geologic repository. The nuclear waste vitrification process requires assurance of a quality product with little or no final inspection. Statistical process control (SPC) is a quantitative approach to one quality assurance aspect of vitrified nuclear waste. This method for monitoring and controlling a process in the presence of uncertainties provides a statistical basis for decisions concerning product quality improvement. Statistical process control is shown to be a feasible and beneficial tool to help the waste glass producers demonstrate that the vitrification process can be controlled sufficiently to produce an acceptable product. This quantitative aspect of quality assurance could be an effective means of establishing confidence in the claims to a quality product. 2 refs., 4 figs

  12. Long time storage containers for spent fuels and vitrified wastes: synthesis of the studies

    International Nuclear Information System (INIS)

    Beziat, A.

    2004-01-01

    This report presents a synthesis of the studies relatives to the containers devoted to the long time spent fuels storage and vitrified wastes packages. These studies were realized in the framework of the axis 3 of the law of 1991 on the radioactive wastes management. The first part is devoted to the presentation of the studies. The container sizing studies which constitute the first containment barrier are then presented. The material choice and the closed system are also detailed. The studies were validate by the realization of containers models and an associated demonstration program is proposed. A synthesis of the technical and economical studies allowed to determine the components and operation costs. (A.L.B.)

  13. Numerical modeling of heat outflux from a vitrified high level waste

    International Nuclear Information System (INIS)

    Aravind, Arun; Jayaraj, Aparna; Seshadri, H.; Balasubramaniyan, V.

    2018-01-01

    Heat generating vitrified high-level waste is initially stored in interim storage facility with adequate cooling for sufficient period of time, and then proposed to be disposed of in deep geological repositories. Heat flux from the waste form can cause thermo mechanical changes within the disposal module and also in the surrounding rock. It may change the permeability of rock fractures over a period of time. It is very essential to study the long term performance of deep geological repository to build confidence in the design and over all operation of the disposal facility. In this study a numerical model was developed to study the temperature distribution in the waste matrix and also the heat out flux to the surrounding rock matrix

  14. Factors Analysis of Spontaneous Abortion after Thawed-vitrified Blastocysts Transfer

    Institute of Scientific and Technical Information of China (English)

    Dong YANG; Zheng-yi SUN; Cheng-yan DENG; Qi YU; Fang-fang HE

    2008-01-01

    Objective To investigate the factors resulting in spontaneous abortion after transferring frozen-thawing blastocysts. Methods A total of 108 cases transferring vitrified blastocysts were divided into two groups: abortion group (n =20) and ongoing group (n=88). Cytogenetic analysis of apoblemas was performed in 12 cases of the abortion.Results The overall spontaneous abortion rate was 18.50%(20/108) and the early spontaneous rate was 16.67%(18/108). ,4 significant difference in maternal age was observed (abortion group: 33.3±4.0 years, ongoing group: 31.0±3.6 years, P=0.02). No difference in other parameters was found. Cytogenetic analysis of apoblemas was obtained for 12 cases, and 2 specimens were contaminated. Seven of ten patients had abnormal karyotypes. Conclusion The underlying cause of spontaneous abortion after transferring frozen thawing blastocysts appears to be abnormal karyotypes.Advancing maternal age seems to increase the risk of spontaneous abortion.

  15. Intermediate storage facility for vitrified high level waste from the reprocessing of spent nuclear fuel

    International Nuclear Information System (INIS)

    1978-04-01

    An intermediate storage facility for vitrified high level waste is described. The design was made specifically for Swedish conditions but can due to modular design be applied also for other conditions. Most of the plant is located underground with a rock cover of about 30 m in order to provide protection against external forces such as acts of war and sabotage. The storage area consists of four caverns each with 150 pits. Each pit can take 10 waste cylinders of 0.4 m diameter and 1.5 m length containing 150 liters of glass. The capacity can be increased by adding additional caverns. Cooling is obtained by forced air convection. Reception areas, auxiliary systems and operation of the plant are also described

  16. Will vitrified high active reactor waste be deposited on the seabed

    International Nuclear Information System (INIS)

    Koksvik, R.M.

    1978-01-01

    The NRPB in the UK has carried out a preliminary study on the consequences of the disposal of high active waste on the ocean bed at great depths. This is reported in 'Assessment of the radiological protection aspects of disposal of high level waste on the ocean floor', by P.D. Grimswood and G.A.M. Webb (NRPB-R 48). This report is here briefly summarised and commented on. It deals with the radiological consequences to man of the erosion and corrosion of glassified (vitrified) radioactive waste, in the deep (>4000m) ocean, radionuclide migration and path ways to man. The conclusion is that considerations of radiological protection do not preclude the disposal of specially treated radioactive waste on the ocean bed. (JIW)

  17. Performance assessment of the disposal of vitrified high-level waste in a clay layer

    International Nuclear Information System (INIS)

    Mallants, Dirk; Marivoet, Jan; Sillen, Xavier

    2001-01-01

    Deep disposal is considered a safe solution to the management of high-level radioactive waste. The safety is usually demonstrated by means of a performance assessment. This paper discusses the methodological aspects and some of the results obtained for the performance assessment of the disposal of vitrified high-level waste in a clay layer in Belgium. The calculations consider radionuclide migration through the following multi-barrier components, all of which contribute to the overall safety: (1) engineered barriers and the host clay layer, (2) overlying aquifer, and (3) biosphere. The interfaces between aquifers and biosphere are limited to the well and river pathway. Results of the performance assessment calculations are given in terms of the time evolution of the dose rates of the most important fission and activation products and actinides. The role of the glass matrix in the overall performance of the repository is also discussed

  18. Evaluation of non-destructive methods for quality checking of vitrified high level waste

    International Nuclear Information System (INIS)

    Huddleston, J.; Hutchinson, I.G.; Metcalfe, B; Mossop, J.R.; Taylor, B.L.; Wilkins, C.G.

    1990-03-01

    Tomography and X-ray absorptiometry have been performed on a container of vitrified high level waste produced by the FINGAL process in 1966. The glass weighed 40-50 kg and when produced contained 10 14 Bq of β/γ activity. The studies have been carried out without recourse to specialised high activity handling facilities. Measurements were carried out by lowering the glass from a shielded container, through a measurement collar, into one of the original storage holes in the floor of the FINGAL plant. The tomographs showed clearly various artefacts in the glass but no cracks or voids were observed within the resolution of the method (0.5-1 mm). The X-ray absorptiometric measurements were made using a 160 kV tube. They showed the presence of about 7% uranium (determined from the magnitude of its K-absorption edge). The resulting strong absorption of X-rays limited the measurements that could be made. (author)

  19. Efficient production of live offspring from mouse oocytes vitrified with a novel cryoprotective agent, carboxylated ε-poly-L-lysine.

    Directory of Open Access Journals (Sweden)

    Hitomi Watanabe

    Full Text Available In cryopreservation of mammalian germ cells, unfertilized oocytes are one of the most available stages because these cryopreserved oocytes can be used for assisted reproductive technologies, including in vitro fertilization (IVF and intracytoplasmic sperm injection. However, it has been generally reported that the fertility and developmental ability of the oocytes are reduced by cryopreservation. Therefore further improvement will be required. Very recently, a new cryoprotective agent (CPA, called as carboxylated ε-poly-L-lysine (COOH-PLL, has been developed to reduce physical and physiological damage by cryopreservation in mammalian stem cells. However, it is unclear the effect of COOH-PLL on fertility and developmental ability of vitrified oocytes. In this study, we used COOH-PLL as a CPA with ethylene glycol (EG for vitrification of mouse oocytes. Cumulus-oocyte complexes (COCs were collected from ICR mice and then vitrified with Cryotop using different concentration of COOH-PLL and EG. A combined treatment with COOH-PLL and EG showed high survival rate (more than 90% of vitrified-warmed COCs after in vitro fertilization. In addition, the fertility and developmental ability of COCs vitrified with E20P10 [EG 20% (v/v and COOH-PLL 10% (w/v] or E15P15 group (EG 15% and COOH-PLL 15% were significantly higher than those with E10P20 (EG10% and COOH-PLL 20% or P30 group (PLL30%. The vitrified COCs in E20P10 group developed to term at a high success rate (46.2% and it was significantly higher than that in control (E30 group (34.8%. Our present study demonstrated for the first time that COOH-PLL is effective for vitrification of mouse oocytes.

  20. Clinical outcome of fresh and vitrified-warmed blastocyst and cleavage-stage embryo transfers in ethnic Chinese ART patients

    Directory of Open Access Journals (Sweden)

    Tong Guo

    2012-10-01

    Full Text Available Abstract Objectives This study sought to evaluate the outcome of fresh and vitrified-warmed cleavage-stage and blastocyst-stage embryo transfers in patients undergoing ART treatment within an ethnic Chinese population. Study design We compared the clinical results of embryo transfer on the 3rd (cleavage stage or 5th (blastocyst stage day after oocyte retrieval, including clinical pregnancy rates, implantation rates and multiple pregnancy rates. Results Our data showed that blastocyst transfer on day 5 did not significantly increase clinical pregnancy rate (41.07% vs 47.08%, p>0.05 and implantation rate (31.8% vs 31.2%, p>0.05 in patients under 35 years of age, in comparison with day 3 cleavage stage embryo transfer. In patients older than 35 years of age, the clinical pregnancy rate after blastocyst transfer was slightly decreased compared with cleavage stage embryo transfer (33.33% vs 42.31%, p>0.05. Unexpectedly, It was found that vitrified-warmed blastocyst transfer resulted in significantly higher clinical pregnancy rate (56.8% and implantation rate (47% compared with fresh blastocyst transfer in controlled stimulation cycles (41.07% and 31.8%, respectively. For patients under 35 years of age, the cumulative clinical pregnancy rate combining fresh and vitrified-warmed blastocyst transfer cycles were significantly higher compared to just cleavage-stage embryo transfer (70.1% versus 51.8%, p Conclusions In an ethnic Chinese patient population, fresh blastocyst transfer does not significantly increase clinical pregnancy rate. However, subsequent vitrified-warmed blastocyst transfer in a non-controlled ovarian hyperstimulation cycle dramatically improves clinical outcomes. Therefore, blastocyst culture in tandem with vitrified-warmed blastocyst transfer is recommended as a favourable and promising protocol in human ART treatment, particularly for ethnic Chinese patients.

  1. Clinical outcome of fresh and vitrified-warmed blastocyst and cleavage-stage embryo transfers in ethnic Chinese ART patients.

    Science.gov (United States)

    Tong, Guo Qing; Cao, Shan Ren; Wu, Xun; Zhang, Jun Qiang; Cui, Ji; Heng, Boon Chin; Ling, Xiu Feng

    2012-10-05

    This study sought to evaluate the outcome of fresh and vitrified-warmed cleavage-stage and blastocyst-stage embryo transfers in patients undergoing ART treatment within an ethnic Chinese population. We compared the clinical results of embryo transfer on the 3rd (cleavage stage) or 5th (blastocyst stage) day after oocyte retrieval, including clinical pregnancy rates, implantation rates and multiple pregnancy rates. Our data showed that blastocyst transfer on day 5 did not significantly increase clinical pregnancy rate (41.07% vs 47.08%, p>0.05) and implantation rate (31.8% vs 31.2%, p>0.05) in patients under 35 years of age, in comparison with day 3 cleavage stage embryo transfer. In patients older than 35 years of age, the clinical pregnancy rate after blastocyst transfer was slightly decreased compared with cleavage stage embryo transfer (33.33% vs 42.31%, p>0.05). Unexpectedly, It was found that vitrified-warmed blastocyst transfer resulted in significantly higher clinical pregnancy rate (56.8%) and implantation rate (47%) compared with fresh blastocyst transfer in controlled stimulation cycles (41.07% and 31.8%, respectively). For patients under 35 years of age, the cumulative clinical pregnancy rate combining fresh and vitrified-warmed blastocyst transfer cycles were significantly higher compared to just cleavage-stage embryo transfer (70.1% versus 51.8%, p<0.05). However, the cumulative multiple pregnancy rates showed no significant difference between the two groups. In an ethnic Chinese patient population, fresh blastocyst transfer does not significantly increase clinical pregnancy rate. However, subsequent vitrified-warmed blastocyst transfer in a non-controlled ovarian hyperstimulation cycle dramatically improves clinical outcomes. Therefore, blastocyst culture in tandem with vitrified-warmed blastocyst transfer is recommended as a favourable and promising protocol in human ART treatment, particularly for ethnic Chinese patients.

  2. Near-surface storage facilities for vitrified high-level wastes

    International Nuclear Information System (INIS)

    Kondrat'ev, A.N.; Kulichenko, V.V.; Kryukov, I.I.; Krylova, N.V.; Paramoshkin, V.I.; Strakhov, M.V.

    1980-01-01

    Concurrently with the development of methods for solidifying liquid radioactive wastes, reliable and safe methods for the storage and disposal of solidified wastes are being devised in the USSR and other countries. One of the main factors affecting the choice of storage conditions for solidified wastes originating from the vitrification of high-level liquid wastes from fuel reprocessing plants is the problem of removing the heat produced by radioactive decay. In order to prevent the temperature of solidified wastes from exceeding the maximum permissible level for the material concerned, it is necessary to limit either the capacity of waste containers or the specific heat release of the wastes themselves. In order that disposal of high-level wastes in geological formations should be reliable and economic, solidified wastes undergo interim storage in near-surface storage facilities with engineered cooling systems. The paper demonstrates the relative influences of specific heat release, of the maximum permissible storage temperature for vitrified wastes and of the methods chosen for cooling wastes in order for the dimensions of waste containers to be reduced to the extent required. The effect of concentrating wastes to a given level in the vitrification process on the cost of storage in different types of storage facility is also examined. Calculations were performed for the amount of vitrified wastes produced by a reprocessing plant with a capacity of five tonnes of uranium per 24 hours. Fuel elements from reactors of the water-cooled, water-moderated type are sent for reprocessing after having been held for about two years. The dimensions of the storage facility are calculated on the assumption that it will take five years to fill

  3. Excitotoxic effects of non-NMDA receptor agonists in organotypic corticostriatal slice cultures

    DEFF Research Database (Denmark)

    Kristensen, B W; Noraberg, J; Jakobsen, B

    1999-01-01

    of the cytosolic enzyme lactate dehydrogenase (LDH) into the culture medium and loss of glutamic acid decarboxylase (GAD) activity in the tissue. Histological sections were also stained by the fluorescent dye Fluoro-Jade (FJ), for degenerating neurons and by immunocytochemical staining for gamma-aminobutyric acid...... density of Fluoro-Jade staining, (3) loss of GAD-activity in tissue homogenates, and (4) loss of GABA-immunostained neurons. We conclude that both differences between compounds (AMPA vs. KA) and brain areas (striatum vs. cortex) can be demonstrated in corticostriatal slice cultures, which in conjunction...... in corticostriatal slice cultures. The purpose was to examine the feasibility of these cultures for excitotoxic studies, and to demonstrate possible differential excitotoxic effects of KA and AMPA on striatal and cortical neurons. Slices of dorsolateral striatum with overlying neocortex were obtained from neonatal...

  4. Analysis of lipid raft molecules in the living brain slices.

    Science.gov (United States)

    Kotani, Norihiro; Nakano, Takanari; Ida, Yui; Ito, Rina; Hashizume, Miki; Yamaguchi, Arisa; Seo, Makoto; Araki, Tomoyuki; Hojo, Yasushi; Honke, Koichi; Murakoshi, Takayuki

    2017-08-24

    Neuronal plasma membrane has been thought to retain a lot of lipid raft components which play important roles in the neural function. Although the biochemical analyses of lipid raft using brain tissues have been extensively carried out in the past 20 years, many of their experimental conditions do not coincide with those of standard neuroscience researches such as neurophysiology and neuropharmacology. Hence, the physiological methods for lipid raft analysis that can be compatible with general neuroscience have been required. Herein, we developed a system to physiologically analyze ganglioside GM1-enriched lipid rafts in brain tissues using the "Enzyme-Mediated Activation of Radical Sources (EMARS)" method that we reported (Kotani N. et al. Proc. Natl. Acad. Sci. U S A 105, 7405-7409 (2008)). The EMARS method was applied to acute brain slices prepared from mouse brains in aCSF solution using the EMARS probe, HRP-conjugated cholera toxin subunit B, which recognizes ganglioside GM1. The membrane molecules present in the GM1-enriched lipid rafts were then labeled with fluorescein under the physiological condition. The fluorescein-tagged lipid raft molecules called "EMARS products" distributed differentially among various parts of the brain. On the other hand, appreciable differences were not detected among segments along the longitudinal axis of the hippocampus. We further developed a device to label the lipid raft molecules in acute hippocampal slices under two different physiological conditions to detect dynamics of the lipid raft molecules during neural excitation. Using this device, several cell membrane molecules including Thy1, known as a lipid raft resident molecule in neurons, were confirmed by the EMARS method in living hippocampal slices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Radioisotopic investigations of zinc uptake into brain slices

    International Nuclear Information System (INIS)

    Howell, G.A.

    1983-01-01

    The presence of zinc in the vicinity of the hippocampal mossy fibers has been repeatedly demonstrated, and several lines of evidence suggest that the mossy-fiber zinc is concentrated within the terminals of mossy fibers. In search of insight into the metabolism and function of mossy-fiber zinc, the present study investigated the transport of zinc into tissue slices and the response of the zinc transport to depolarization. Kinetic analysis of zinc accumulation by mouse brain slices in vitro revealed the presence of a high affinity uptake component with an apparent Km of 17.7 μM for hippocampus, 16.6 μM< for cortex and 25 μM for striatum and a V/sub max/ of 9.2 ng/mg/hr for the hippocampus, 10.1 ng/mg/hr for cortex and 9.6 ng/mg/hr for striatum. Cytoarchitectonic differences in zinc transport between the different hippocampal subregions were found with those regions containing granule cells or mossy fiber axons accumulating greater amounts of zinc than the CA 1 region. The present finding that mossy-fiber neuropil selectivity accumulates zinc suggests the presence of a zinc-binding substance unique to mossy-fiber tissue

  6. Isoproterenol effects evaluated in heart slices of human and rat in comparison to rat heart in vivo

    International Nuclear Information System (INIS)

    Herrmann, Julia E.; Heale, Jason; Bieraugel, Mike; Ramos, Meg; Fisher, Robyn L.; Vickers, Alison E.M.

    2014-01-01

    Human response to isoproterenol induced cardiac injury was evaluated by gene and protein pathway changes in human heart slices, and compared to rat heart slices and rat heart in vivo. Isoproterenol (10 and 100 μM) altered human and rat heart slice markers of oxidative stress (ATP and GSH) at 24 h. In this in vivo rat study (0.5 mg/kg), serum troponin concentrations increased with lesion severity, minimal to mild necrosis at 24 and 48 h. In the rat and the human heart, isoproterenol altered pathways for apoptosis/necrosis, stress/energy, inflammation, and remodeling/fibrosis. The rat and human heart slices were in an apoptotic phase, while the in vivo rat heart exhibited necrosis histologically and further progression of tissue remodeling. In human heart slices genes for several heat shock 70 kD members were altered, indicative of stress to mitigate apoptosis. The stress response included alterations in energy utilization, fatty acid processing, and the up-regulation of inducible nitric oxide synthase, a marker of increased oxidative stress in both species. Inflammation markers linked with remodeling included IL-1α, Il-1β, IL-6 and TNFα in both species. Tissue remodeling changes in both species included increases in the TIMP proteins, inhibitors of matrix degradation, the gene/protein of IL-4 linked with cardiac fibrosis, and the gene Ccl7 a chemokine that induces collagen synthesis, and Reg3b a growth factor for cardiac repair. This study demonstrates that the initial human heart slice response to isoproterenol cardiac injury results in apoptosis, stress/energy status, inflammation and tissue remodeling at concentrations similar to that in rat heart slices. - Highlights: • Human response to isoproterenol induced cardiac injury evaluated in heart slices. • Isoproterenol altered apoptosis, energy, inflammation and remodeling pathways. • Human model verified by comparison to rat heart slices and rat heart in vivo. • Human and rat respond to isoproterenol

  7. Coupling of organotypic brain slice cultures to silicon-based arrays of electrodes

    DEFF Research Database (Denmark)

    Jahnsen, Henrik; Kristensen, Bjarne Winther; Thiébaud, P

    1999-01-01

    Fetal or early postnatal brain tissue can be cultured in viable and healthy condition for several weeks with development and preservation of the basic cellular and connective organization as so-called organotypic brain slice cultures. Here we demonstrate and describe how it is possible to establish...

  8. Brain Slice Staining and Preparation for Three-Dimensional Super-Resolution Microscopy

    Science.gov (United States)

    German, Christopher L.; Gudheti, Manasa V.; Fleckenstein, Annette E.; Jorgensen, Erik M.

    2018-01-01

    Localization microscopy techniques – such as photoactivation localization microscopy (PALM), fluorescent PALM (FPALM), ground state depletion (GSD), and stochastic optical reconstruction microscopy (STORM) – provide the highest precision for single molecule localization currently available. However, localization microscopy has been largely limited to cell cultures due to the difficulties that arise in imaging thicker tissue sections. Sample fixation and antibody staining, background fluorescence, fluorophore photoinstability, light scattering in thick sections, and sample movement create significant challenges for imaging intact tissue. We have developed a sample preparation and image acquisition protocol to address these challenges in rat brain slices. The sample preparation combined multiple fixation steps, saponin permeabilization, and tissue clarification. Together, these preserve intracellular structures, promote antibody penetration, reduce background fluorescence and light scattering, and allow acquisition of images deep in a 30 μm thick slice. Image acquisition challenges were resolved by overlaying samples with a permeable agarose pad and custom-built stainless steel imaging adapter, and sealing the imaging chamber. This approach kept slices flat, immobile, bathed in imaging buffer, and prevented buffer oxidation during imaging. Using this protocol, we consistently obtained single molecule localizations of synaptic vesicle and active zone proteins in three-dimensions within individual synaptic terminals of the striatum in rat brain slices. These techniques may be easily adapted to the preparation and imaging of other tissues, substantially broadening the application of super-resolution imaging. PMID:28924666

  9. Effects of chemotherapeutics on organotypic corticostriatal slice cultures identified by a panel of fluorescent and immunohistochemical markers

    DEFF Research Database (Denmark)

    Nørregaard, Annette; Jensen, Stine Skov; Kolenda, Jesper

    2012-01-01

    no toxicity was observed. Corresponding immunostaining showed loss of MAP2 and increased expression of GFAP and p25α for cultures exposed to 1,000 nM VCR. Cultures exposed to high concentrations of ACNU and IM disintegrated, leaving no tissue for histology. In conclusion, corticostriatal slice cultures...... specific neuronal and glial degeneration induced by chemotherapeutics in organotypic rat corticostriatal slice cultures. The slice cultures were exposed to the alkylating agents temozolomide (TMZ) and nimustine (ACNU), the tyrosine kinase inhibitor imatinib mesylate (IM) and the microtubule...

  10. Interactive Slice of the CMS detector

    CERN Multimedia

    Davis, Siona Ruth

    2016-01-01

    This slice shows a colorful cross-section of the CMS detector with all parts of the detector labelled. Viewers are invited to click on buttons associated with five types of particles to see what happens when each type interacts with the sections of the detector. The five types of particles users can select to send through the slice are muons, electrons, neutral hadrons, charged hadrons and photons. Supplementary information on each type of particles is given. Useful for inclusion into general talks on CMS etc. *Animated CMS "slice" for Powerpoint (Mac & PC) Original version - 2004 Updated version - July 2010 *Six slides required - first is a set of buttons; others are for each particle type (muon, electron, charged/neutral hadron, photon) Recommend putting slide 1 anywhere in your presentation and the rest at the end

  11. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  12. Introduction to bit slices and microprogramming

    International Nuclear Information System (INIS)

    Van Dam, A.

    1981-01-01

    Bit-slice logic blocks are fourth-generation LSI components which are natural extensions of traditional mulitplexers, registers, decoders, counters, ALUs, etc. Their functionality is controlled by microprogramming, typically to implement CPUs and peripheral controllers where both speed and easy programmability are required for flexibility, ease of implementation and debugging, etc. Processors built from bit-slice logic give the designer an alternative for approaching the programmibility of traditional fixed-instruction-set microprocessors with a speed closer to that of hardwired random logic. (orig.)

  13. Slice through an LHC bending magnet

    CERN Multimedia

    Slice through an LHC superconducting dipole (bending) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. There are 1232 15m long dipole magnets in the LHC.

  14. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  15. Formation of secondary phases during the corrosion of vitrified nuclear waste

    International Nuclear Information System (INIS)

    Zimmer, P.

    2003-11-01

    The first aim of this work was the examination of the formation and long-term stability of secondary phases that form during an aquatic attack on simulated, vitrified nuclear waste. In the glasses used for the investigations actinides had been replaced by rare earth elements (chemical analogues), other radionuclides by inactive isotopes. For predictions about the long-term safety of nuclear waste disposals it is important to identify secondary phases that have formed during the glass corrosion process and to determine their stability. Two different saline solutions (rich in MgCl 2 and in NaCl, respectively) are relevant as a corrosion medium for waste disposals. It showed that in such an environment sulfates, silicates and molybdates represent the main new formations of minerals after 7.5 years of corrosion. However, the formation, long-term stability and sorption characteristics of those minerals regarding rare earth elements depend to a high degree on the corrosion medium as well as on changes in the geochemical environment in the course of the experiment. By means of SEM/EDX barytes of different morphology with up to 15% w/w Sr ((Ba,Sr)SO 4 ) were identified in both corrosion media; they were capable of binding long-term stable radionuclides like Sr. Furthermore, pure rare earth (RE) sulfates were observed in the saline solution rich in MgCl 2 . This formation of RE-sulfates has not been described in the literature so far. Depending on the saline solution, the secondary silicate and molybdate minerals that formed on the glass surfaces differed noticeably in their sorption characteristics and their stability. Another focus of the work was a more profound understanding of the glass corrosion mechanism in the presence of metallic iron since steel jackets are used as technical barriers for the vitrified nuclear waste in nuclear waste disposals. Another important point in connection with the mobilization and immobilization of radionuclides released during glass

  16. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    International Nuclear Information System (INIS)

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-01

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies

  17. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction.

    Science.gov (United States)

    den Harder, J Chiel; van Yperen, Gert H; Blume, Ulrike A; Bos, Clemens

    2015-01-01

    Multispectral imaging (MSI) significantly reduces metal artifacts. Yet, especially in techniques that use gradient selection, such as slice encoding for metal artifact correction (SEMAC), a residual ripple artifact may be prominent. Here, an analysis is presented of the ripple artifact and of slice overlap as an approach to reduce the artifact. The ripple artifact was analyzed theoretically to clarify its cause. Slice overlap, conceptually similar to spectral bin overlap in multi-acquisition with variable resonances image combination (MAVRIC), was achieved by reducing the selection gradient and, thus, increasing the slice profile width. Time domain simulations and phantom experiments were performed to validate the analyses and proposed solution. Discontinuities between slices are aggravated by signal displacement in the frequency encoding direction in areas with deviating B0. Specifically, it was demonstrated that ripple artifacts appear only where B0 varies both in-plane and through-plane. Simulations and phantom studies of metal implants confirmed the efficacy of slice overlap to reduce the artifact. The ripple artifact is an important limitation of gradient selection based MSI techniques, and can be understood using the presented simulations. At a scan-time penalty, slice overlap effectively addressed the artifact, thereby improving image quality near metal implants. © 2014 Wiley Periodicals, Inc.

  18. Chemically durable iron phosphate glasses for vitrifying sodium bearing waste (SBW) using conventional and cold crucible induction melting (CCIM) techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kim, C.W. E-mail: cheol@umr.edu; Ray, C.S.; Zhu, D.; Day, D.E.; Gombert, D.; Aloy, A.; Mogus-Milankovic, A.; Karabulut, M

    2003-11-01

    A simulated sodium bearing waste (SBW) was successfully vitrified in iron phosphate glasses (IPG) at a maximum waste loading of 40 wt% using conventional and cold crucible induction melting (CCIM) techniques. No sulfate segregation or crystalline phases were detectable in the IPG when examined by SEM and XRD. The IPG wasteforms containing 40 wt% SBW satisfy current DOE requirements for aqueous chemical durability as evaluated from their bulk dissolution rate (D{sub R}), product consistency test, and vapor hydration test. The fluid IPG wasteforms can be melted at a relatively low temperature (1000 deg. C) and for short times (<6 h). These properties combined with a significantly higher waste loading, and the feasibility of CCIM melting offer considerable savings in time, energy, and cost for vitrifying the SBW stored at the Idaho National Engineering and Environmental Laboratory in iron phosphate glasses.

  19. Evaluation of the safety of vitrified high level waste shipments from the UK to continental Europe by sea. Annex 2

    International Nuclear Information System (INIS)

    Lange, F.; Fett, H.J.; Hoermann, E.; Roewekamp, M.; Cheshire, R.; Elston, B.; Slawson, G.; Raffestin, D.; Schneider, T.; Armingaud, F.; Laurent, B.

    2001-01-01

    The return of vitrified high level waste arising from the reprocessing of spent nuclear fuel at Sellafield to continental Europe, e.g. Germany, will start around the end of the century. The shipment of the specific flasks will include transportation via the Irish Sea, the English Channel and the North Sea with ships of the Pacific Nuclear Transport Limited (PNTL) classified to the INF 3 standard. The assessment approach is to analyse the severity and the frequency of mechanical impacts, fires and explosions with the potential to affect the package. The results show that there is a high safety margin due to the special safety features of the INF 3 ships compared to conventional ships. The remaining accident probability for a trans-port of vitrified high level waste from UK to the continent is very low. No realistic severe accident scenarios that could seriously affect the flasks and could lead to a radioactivity re-lease have been identified. (author)

  20. Organotypic brain slice cultures of adult transgenic P301S mice--a model for tauopathy studies.

    Directory of Open Access Journals (Sweden)

    Agneta Mewes

    Full Text Available BACKGROUND: Organotypic brain slice cultures represent an excellent compromise between single cell cultures and complete animal studies, in this way replacing and reducing the number of animal experiments. Organotypic brain slices are widely applied to model neuronal development and regeneration as well as neuronal pathology concerning stroke, epilepsy and Alzheimer's disease (AD. AD is characterized by two protein alterations, namely tau hyperphosphorylation and excessive amyloid β deposition, both causing microglia and astrocyte activation. Deposits of hyperphosphorylated tau, called neurofibrillary tangles (NFTs, surrounded by activated glia are modeled in transgenic mice, e.g. the tauopathy model P301S. METHODOLOGY/PRINCIPAL FINDINGS: In this study we explore the benefits and limitations of organotypic brain slice cultures made of mature adult transgenic mice as a potential model system for the multifactorial phenotype of AD. First, neonatal (P1 and adult organotypic brain slice cultures from 7- to 10-month-old transgenic P301S mice have been compared with regard to vitality, which was monitored with the lactate dehydrogenase (LDH- and the MTT (3-(4,5-Dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide assays over 15 days. Neonatal slices displayed a constant high vitality level, while the vitality of adult slice cultures decreased significantly upon cultivation. Various preparation and cultivation conditions were tested to augment the vitality of adult slices and improvements were achieved with a reduced slice thickness, a mild hypothermic cultivation temperature and a cultivation CO(2 concentration of 5%. Furthermore, we present a substantial immunohistochemical characterization analyzing the morphology of neurons, astrocytes and microglia in comparison to neonatal tissue. CONCLUSION/SIGNIFICANCE: Until now only adolescent animals with a maximum age of two months have been used to prepare organotypic brain slices. The current study

  1. The potential use of transmission tomography techniques for the quality checking of cement encapsulated and vitrified wastes

    International Nuclear Information System (INIS)

    Huddleston, J.; Hutchinson, I.G.; Burch, S.F.; Perring, J.K.

    1989-01-01

    The technique of extracting information from real-time radiographic images and processing that data using tomographic reconstruction methods has been demonstrated using simulated full-sized specimens of encapsulated intermediate level waste and high level vitrified waste. Sections of these objects are produced perpendicular to the plane of the radiographs from which they originate. The resulting section is clearer and more informative than the radiographs for complex specimens. The technique is proposed as a complementary stage to existing radiographic analyses. (author)

  2. Effects of Temperature and Slice Thickness on Drying Kinetics of Pumpkin Slices

    OpenAIRE

    Kongdej LIMPAIBOON

    2011-01-01

    Dried pumpkin slice is an alternative crisp food product. In this study, the effects of temperature and slice thickness on the drying characteristics of pumpkin were studied in a lab-scale tray dryer, using hot air temperatures of 55, 60 and 65 °C and 2, 3 and 4 mm slice thickness at a constant air velocity of 1.5 m/s. The initial moisture content of the pumpkin samples was 900.5 % (wb). The drying process was carried out until the final moisture content of product was 100.5 % (wb). The resul...

  3. Interagency cooperation in the development of a cost-effective transportation and disposal solution for vitrified radium bearing material

    International Nuclear Information System (INIS)

    Smith, M.L.; Nixon, D.A.; Stone, T.J.; Tope, W.G.; Vogel, R.A.; Allen, R.B.; Schofield, W.D.

    1996-01-01

    Fernald radium bearing ore residue waste, stored within Silos 1 and 2 (K-65) and Silo 3 waste, will be vitrified for disposal at the Nevada Test Site (NTS). A comprehensive, parametric evaluation of waste form, shielding requirements, packaging, and transportation alternatives was completed to identify the safest, most cost-effective approach. The impacts of waste loading, waste form, regulatory requirements, NTS waste acceptance criteria, as-low-as-resonably-achievable principles, and material handling costs were factored into the recommended approach. Through cooperative work between the U.S. Department of Energy (DOE) and the U.S. Department of Transportation (DOT), the vitrified K-65 and Silo 3 radioactive material will be classified consistent with the regulations promulgated by DOT in the September 28, 1995 Federal Register. These new regulations adopt International Atomic Energy Agency language to promote a consistent approach for the transportation and management of radioactive material between the international community and the DOT. Use of the new regulations allows classification of the vitrified radioactive material from the Fernald silos under the designation of low specific activity-II and allows the development of a container that is optimized to maximize payload while minimizing internal void space, external surface radiation levels, and external volume. This approach minimizes the required number of containers and shipments, and the related transportation and disposal costs

  4. Interagency cooperation in the development of a cost-effective transportation and disposal solution for vitrified radium bearing material

    Energy Technology Data Exchange (ETDEWEB)

    Smith, M.L.; Nixon, D.A.; Stone, T.J.; Tope, W.G.; Vogel, R.A. [Fernald Environmental Restoration Management Corp., Cincinnati, OH (United States); Allen, R.B. [USDOE, Fernald Area Office, Cincinnati, OH (United States); Schofield, W.D. [Foster Wheeler Environmental Corp. (United States)

    1996-02-01

    Fernald radium bearing ore residue waste, stored within Silos 1 and 2 (K-65) and Silo 3 waste, will be vitrified for disposal at the Nevada Test Site (NTS). A comprehensive, parametric evaluation of waste form, shielding requirements, packaging, and transportation alternatives was completed to identify the safest, most cost-effective approach. The impacts of waste loading, waste form, regulatory requirements, NTS waste acceptance criteria, as-low-as-resonably-achievable principles, and material handling costs were factored into the recommended approach. Through cooperative work between the U.S. Department of Energy (DOE) and the U.S. Department of Transportation (DOT), the vitrified K-65 and Silo 3 radioactive material will be classified consistent with the regulations promulgated by DOT in the September 28, 1995 Federal Register. These new regulations adopt International Atomic Energy Agency language to promote a consistent approach for the transportation and management of radioactive material between the international community and the DOT. Use of the new regulations allows classification of the vitrified radioactive material from the Fernald silos under the designation of low specific activity-II and allows the development of a container that is optimized to maximize payload while minimizing internal void space, external surface radiation levels, and external volume. This approach minimizes the required number of containers and shipments, and the related transportation and disposal costs.

  5. Thin-Slice Perception Develops Slowly

    Science.gov (United States)

    Balas, Benjamin; Kanwisher, Nancy; Saxe, Rebecca

    2012-01-01

    Body language and facial gesture provide sufficient visual information to support high-level social inferences from "thin slices" of behavior. Given short movies of nonverbal behavior, adults make reliable judgments in a large number of tasks. Here we find that the high precision of adults' nonverbal social perception depends on the slow…

  6. Adaptive slices for acquisition of anisotropic BRDF

    Czech Academy of Sciences Publication Activity Database

    Vávra, Radomír; Filip, Jiří

    (2018) ISSN 2096-0433 R&D Projects: GA ČR GA17-18407S Institutional support: RVO:67985556 Keywords : anisotropic BRDF * slice * sampling Subject RIV: BD - Theory of Information http://library.utia.cas.cz/separaty/2018/RO/vavra-0486116.pdf

  7. Detecting Psychopathy from Thin Slices of Behavior

    Science.gov (United States)

    Fowler, Katherine A.; Lilienfeld, Scott O.; Patrick, Christopher J.

    2009-01-01

    This study is the first to demonstrate that features of psychopathy can be reliably and validly detected by lay raters from "thin slices" (i.e., small samples) of behavior. Brief excerpts (5 s, 10 s, and 20 s) from interviews with 96 maximum-security inmates were presented in video or audio form or in both modalities combined. Forty raters used…

  8. Field characterization plan for the 216-U-8 vitrified clay pipeline

    International Nuclear Information System (INIS)

    Rowley, C.A.

    1994-01-01

    The 216-U-8 Crib was constructed in 1952 and received waste from 1952 to 1960 as described in Appendix A. This description of work details the field activities associated with the characterization of the vitrified clay pipe (VCP) delivery line to the 216-U-8 Crib and subsurface soil sampling along the pipe route in the 200 West Area of Hanford U Plant. It will serves as a field guide for those performing the work. Soil sampling locations will be determined by a combination of radiological surface surveys and internal camera surveys of the VCP line. Depending on the condition of the pipeline and field conditions, the objectives are as follows: examine the internal condition of the VCP with a survey camera to the extent allowed by field conditions; determine precise location and depth of the VCP; document VCP integrity; document gamma radiation profile through the VCP; and correlate any relationships between surface contamination zones at grade above the VCP to identify breaches in the pipe integrity

  9. The design and construction of the windscale vitrification plant and vitrified product store

    International Nuclear Information System (INIS)

    Heafield, W.; Woodall, A.; Elsden, A.D.

    1987-01-01

    The paper describes the background of High Level Waste storage and vitrification development in the UK and its application to Reprocessing Operations at Sellafield. The main stages in the vitrification process and associated maintenance facilities are described together with the layout of the Windscale Vitrification Plant (WVP) and associated Vitrified Product Store (VPS). The design and construction techniques employed for example, the use of Computer Aided Design and the effect of automatic pipe bending/orbital welding and the use of precast units for cell construction, are discussed and current construction progress is highlighted. The vitrification process uses complex mechanical plant operating in high temperature and radiation fields. An extensive engineering and process development programme has been carried out. A full scale inactive facility (FSIF) has been constructed and the objectives and results from the operation of FSIF are presented. In addition to engineering and process development, a comprehensive programme of glass technology development has been carried out to establish maximum waste incorporation levels, reaction kinetic and product properties of the candidate glass formulations

  10. Long-term leaching behavior of vitrified high-level wastes

    International Nuclear Information System (INIS)

    Ishiguro, Katsuhiko; Sonobe, Hitoshi; Sasaki, Noriaki; Kashihara, Hidechiyo

    1985-01-01

    A long-term Soxhlet leaching test, long-term static leaching test, solubility evaluation test and actual-scale glass solid leaching test were carried out for simulated vitrified wastes. Under high flow-rate leachate conditions, the leaching of high-solubility substances such as B and Na increases almost linearly with time while that of Fe, Ni and rare earth metals strongly depends on their solubility. The overall leaching rate changes (tends to decrease) with time under static conditions. The elution or diffusion is the rate determining step in the earlier region of the leaching process while the solubilities of major components have greater effects in the latter region. The change of the dominant leaching mechanism is delayed more largely as the surface-area to leachate-volume (SA/V) ratio decreases. Actual-scale glass specimens showed almost the same leaching behaviors as small-scale ones. If cracks exist in glass solid, the leaching in them is slow causing little effects on the overall leaching rate. This may be due to the fact that solubility-dependent leaching is occuring in the cracks. The long-term static leaching observations were not satisfactorily explained by the MCC-3 type solubility test results. It is important to clarify the solubility-dependent leaching behaviors at large SA/V ratios. (Nogami, K.)

  11. Dry storage technologies: Optimized solutions for spent fuels and vitrified residues

    International Nuclear Information System (INIS)

    Roland, Vincent; Verdier, Antoine; Sicard, Damien; Neider, Tara

    2006-01-01

    ancillary equipment, Ready to move to final or centralized repository or reprocessing facility or other ISFSI, Compact systems, Easy rearrangement, Easy handling; - In favor of concrete shielded canisters based systems: Economics when initial quantity is sufficient to spread out up front equipment investment significant cost - Shielding advantage, Easy local production of the relatively light canisters. Both approaches of dry storage technologies can have a positive impact on their public acceptance because of their non-permanent characteristics and because their transport license refers to internationally recognized rules, standards and methods. Currently, more than 1,000 COGEMA Logistics/Transnuclear Inc. dry storage systems have been ordered in Belgium, Germany, Japan, Switzerland, Armenia and the US. Because of the evolution of burnup of spent fuel to be reprocessed, the high activity vitrified residues cannot be transported in the existing cask designs presently used. Therefore, COGEMA LOGISTICS has decided in the late nineties to develop a brand new design of casks with optimized capacity able to store and transport the most active and hottest canisters: the TN TM 81 casks currently in use in Switzerland and the TN TM 85 cask which shall permit in the near future in Germany the storage and the transport of the most active vitrified residues. The TN TM 81 and the TN TM 85 casks have been designed to fully anticipate shipment constraints of the present vitrified residue production in existing reprocessing facilities. They also used the feedback of current shipments and the operational constraints and experience of receiving and shipping facilities. The casks had to fit as much as possible in the existing procedures for the already existing casks such as the TN TM 28 cask and TS 28 V cask, all along the logistics chain of loading, unloading, transport and maintenance. In addition, years of feedback and experience in design and operations - together with ever improved

  12. Risk analysis of transporting vitrified high-level radioactive waste by train

    International Nuclear Information System (INIS)

    Schneider, K.A.; Merz, E.

    1983-01-01

    Reprocessing plants (RPPs) and final disposal sites for vitrified high level radioactive waste (HLW) will be at distant locations in the Federal Republic of Germany (FRG). HLW will also have to be shipped from RPPs located in foreign countries to a final disposal site in the FRG. Thus transportation of HLW on public routes will become necessary. A model of an HLW shipping system is presented which meets the needs of an established nuclear industry. Reference ages of the HLW were assumed to range between about 5 years and about 50 years. Thus HLW shipping systems covering this period are analyzed. The safety of nuclear installations is ensured by means of a design according to the design based accident. The same applies to shipping casks for radioactive materials (RAM) according to the IAEA Regulations. The aim of this work was to make as complete as reasonably possible an estimate of the risk of shipping HLW. The safety of the system was therefore analyzed by means of probabilistic risk assessment. Release of radioactive material due to transportation accidents is considered. 5 references, 5 figures, 6 tables

  13. Methods of vitrifying waste with low melting high lithia glass compositions

    Science.gov (United States)

    Jantzen, Carol M.; Pickett, John B.; Cicero-Herman, Connie A.; Marra, James C.

    2001-01-01

    The invention relates to methods of vitrifying waste and for lowering the melting point of glass forming systems by including lithia formers in the glass forming composition in significant amounts, typically from about 0.16 wt % to about 11 wt %, based on the total glass forming oxides. The lithia is typically included as a replacement for alkali oxide glass formers that would normally be present in a particular glass forming system. Replacement can occur on a mole percent or weight percent basis, and typically results in a composition wherein lithia forms about 10 wt % to about 100 wt % of the alkali oxide glass formers present in the composition. The present invention also relates to the high lithia glass compositions formed by these methods. The invention is useful for stabilization of numerous types of waste materials, including aqueous waste streams, sludge solids, mixtures of aqueous supernate and sludge solids, combinations of spent filter aids from waste water treatment and waste sludges, supernate alone, incinerator ash, incinerator offgas blowdown, or combinations thereof, geological mine tailings and sludges, asbestos, inorganic filter media, cement waste forms in need of remediation, spent or partially spent ion exchange resins or zeolites, contaminated soils, lead paint, etc. The decrease in melting point achieved by the present invention desirably prevents volatilization of hazardous or radioactive species during vitrification.

  14. Sintered glass ceramic composites from vitrified municipal solid waste bottom ashes

    International Nuclear Information System (INIS)

    Aloisi, Mirko; Karamanov, Alexander; Taglieri, Giuliana; Ferrante, Fabiola; Pelino, Mario

    2006-01-01

    A glass ceramic composite was obtained by sinter-crystallisation of vitrified municipal solid waste bottom ashes with the addition of various percentages of alumina waste. The sintering was investigated by differential dilatometry and the crystallisation of the glass particles by differential thermal analysis. The crystalline phases produced by the thermal treatment were identified by X-ray diffraction analysis. The sintering process was found to be affected by the alumina addition and inhibited by the beginning of the crystal-phase precipitation. Scanning electron microscopy was performed on the fractured sintered samples to observe the effect of the sintering. Young's modulus and the mechanical strength of the sintered glass ceramic and composites were determined at different heating rates. The application of high heating rate and the addition of alumina powder improved the mechanical properties. Compared to the sintered glass ceramic without additives, the bending strength and the Young's modulus obtained at 20 deg. C/min, increased by about 20% and 30%, respectively

  15. Transfer shuttle for vitrified residue canisters control of risks associated with external exposure and heat release

    Energy Technology Data Exchange (ETDEWEB)

    BIndel, L.; Gamess, A.; Lejeune, E.; Cellier, P.; Maillard, A. [SGN Reseau Eurisys, 78 - Saint Quentin (France)

    1998-07-01

    In the La Hague COGEMA's plant area, nuclear residue isolated by reprocessing are transported by means of specific transfer shuttles between the different processing and/or conditioning facilities and the storage ones. These shuttles are designed by reference to the applicable dose equivalent rate (DER) limits for transport on the site and the thermal behavior limitations of certain mechanical components which guarantee the containment of the transported waste. This paper describes and example of a study conducted on a transfer shuttle for vitrified residue canisters. Concerning the control of risks associated with external exposure and with heat releases, these were handled by the 'Shielding-Criticality-Dispersion' and 'process Modelling and Simulation' Sections of the Technical Division of SGN. The dose profiles around the shuttle, as a function of the shielding heterogeneities and possible radiation leakage, as well as the thermal fields within the shuttle, were calculated using 3D models. These design studies ultimately helped to select and validate the optimal solutions. (authors)

  16. Cryo-electron microscopy of vitrified SV40 minichromosomes: the liquid drop model.

    Science.gov (United States)

    Dubochet, J; Adrian, M; Schultz, P; Oudet, P

    1986-03-01

    The structure of SV40 minichromosomes has been studied by cryo-electron microscopy of vitrified thin layers of solution. In high-salt buffer (130 mM NaCl), freshly prepared minichromosomes are condensed into globules 30 nm or more in diameter. On the micrograph, they appear to be formed by the close packing of 10 nm granules which give rise to a 10 nm reflection in the optical diffractogram. The globules can adopt many different conformations. At high concentration, they fuse into a homogeneous 'sea' of closely packed 10 nm granules. In low-salt buffer (less than 10 mM NaCl), the globules open, first into 10 nm filaments, and then into nucleosome-strings. The 'liquid drop' model is proposed to explain the condensed structure of the minichromosome in high-salt buffer: nucleosomes stack specifically on top of one another, thus forming the 10 nm filaments. 10 nm filaments in turn, tend to aggregate laterally. Optimizing both these interactions results in the condensation of 10 nm filaments or portions thereof into a structure similar to that of a liquid. Some implications of this model for the structure of cellular chromatin are discussed.

  17. Waste acceptance and waste loading for vitrified Oak Ridge tank waste

    International Nuclear Information System (INIS)

    Harbour, J.R.; Andrews, M.K.

    1997-01-01

    The Office of Science and Technology of the DOE has funded a joint project between the Oak Ridge National Laboratory (ORNL) and the Savannah River Technology Center (SRTC) to evaluate vitrification and grouting for the immobilization of sludge from ORNL tank farms. The radioactive waste is from the Gunite and Associated Tanks (GAAT), the Melton Valley Storage Tanks (MVST), the Bethel Valley Evaporator Service Tanks (BVEST), and the Old Hydrofractgure Tanks (OHF). Glass formulation development for sludge from these tanks is discussed in an accompanying article for this conference (Andrews and Workman). The sludges contain transuranic radionuclides at levels which will make the glass waste form (at reasonable waste loadings) TRU. Therefore, one of the objectives for this project was to ensure that the vitrified waste form could be disposed of at the Waste Isolation Pilot Plant (WIPP). In order to accomplish this, the waste form must meet the WIPP Waste Acceptance Criteria (WAC). An alternate pathway is to send the glass waste forms for disposal at the Nevada Test Site (NTS). A sludge waste loading in the feed of 6 wt percent will lead to a waste form which is non-TRU and could potentially be disposed of at NTS. The waste forms would then have to meet the requirements of the NTS WAC. This paper presents SRTC''s efforts at demonstrating that the glass waste form produced as a result of vitrification of ORNL sludge will meet all the criteria of the WIPP WAC or NTS WAC

  18. Electrochemical reduction behavior of simplified simulants of vitrified radioactive waste in molten CaCl2

    Science.gov (United States)

    Katasho, Yumi; Yasuda, Kouji; Nohira, Toshiyuki

    2018-05-01

    The electrochemical reduction of two types of simplified simulants of vitrified radioactive waste, simulant 1 (glass component only: SiO2, B2O3, Na2O, Al2O3, CaO, Li2O, and ZnO) and simulant 2 (also containing long-lived fission product oxides, ZrO2, Cs2O, PdO, and SeO2), was investigated in molten CaCl2 at 1103 K. The behavior of each element was predicted from the potential-pO2- diagram constructed from thermodynamic data. After the immersion of simulant 1 into molten CaCl2 without electrolysis, the dissolution of Na, Li, and Cs was confirmed by inductively coupled plasma atomic emission spectrometry and mass spectrometry analysis of the samples. The scanning electron microscopy/energy dispersive X-ray and X-ray diffraction analyses of simulants 1 and 2 electrolyzed at 0.9 V vs. Ca2+/Ca confirmed that most of SiO2 had been reduced to Si. After the electrolysis of simulants 1 and 2, Al, Zr, and Pd remained in the solid phase. In addition, SeO2 was found to remain partially in the solid phase and partially evaporate, although a small quantity dissolved into the molten salt.

  19. A Review of Iron Phosphate Glasses and Recommendations for Vitrifying Hanford Waste

    Energy Technology Data Exchange (ETDEWEB)

    Delbert E. Ray; Chandra S. Ray

    2013-11-01

    This report contains a comprehensive review of the research conducted, world-wide, on iron phosphate glass over the past ~30 years. Special attention is devoted to those iron phosphate glass compositions which have been formulated for the purpose of vitrifying numerous types of nuclear waste, with special emphasis on the wastes stored in the underground tanks at Hanford WA. Data for the structural, chemical, and physical properties of iron phosphate waste forms are reviewed for the purpose of understanding their (a) outstanding chemical durability which meets all current DOE requirements, (b) high waste loadings which can exceed 40 wt% (up to 75 wt%) for several Hanford wastes, (c) low melting temperatures, can be as low as 900°C for certain wastes, and (d) high tolerance for “problem” waste components such as sulfates, halides, and heavy metals (chromium, actinides, noble metals, etc.). Several recommendations are given for actions that are necessary to smoothly integrate iron phosphate glass technology into the present waste treatment plans and vitrification facilities at Hanford.

  20. Effects of High Hydrostatic Pressure on Expression Profiles of In Vitro Produced Vitrified Bovine Blastocysts

    Science.gov (United States)

    Jiang, Zongliang; Harrington, Patrick; Zhang, Ming; Marjani, Sadie L.; Park, Joonghoon; Kuo, Lynn; Pribenszky, Csaba; Tian, Xiuchun (Cindy)

    2016-01-01

    High hydrostatic pressure (HHP) has been used to pre-condition embryos before essential, yet potentially detrimental procedures such as cryopreservation. However, the mechanisms for HHP are poorly understood. We treated bovine blastocysts with three different HHP (40, 60 and 80 MPa) in combination with three recovery periods (0, 1 h, 2 h post HHP). Re-expansion rates were significantly higher at 40 and 60 but lower at 80 MPa after vitrification-warming in the treated groups than controls. Microarray analysis revealed 399 differentially expressed transcripts, representing 254 unique genes, among different groups. Gene ontology analysis indicated that HHP at 40 and 60 MPa promoted embryo competence through down-regulation of genes in cell death and apoptosis, and up-regulation of genes in RNA processing, cellular growth and proliferation. In contrast, 80 MPa up-regulated genes in apoptosis, and down-regulated protein folding and cell cycle-related genes. Moreover, gene expression was also influenced by the length of the recovery time after HHP. The significantly over-represented categories were apoptosis and cell death in the 1 h group, and protein folding, response to unfolded protein and cell cycle in the 2 h group compared to 0 h. Taken together, HHP promotes competence of vitrified bovine blastocysts through modest transcriptional changes. PMID:26883277

  1. Development of a unit cell model for interim performance assessment of vitrified low level waste disposal

    International Nuclear Information System (INIS)

    Kline, N.W.

    1995-09-01

    The unit cell modeling approach has been developed and used in analysis of some design options for a vitrified low level waste disposal facility. The unit cell modeling approach is likely to be useful in interim performance assessment for the facility. The present unit cell model will probably need to be refitted in terms of some model parameters for the latter purpose. Two present disposal facility concepts differ in the length of a capillary barrier proposed to limit effective recharge through the top of the facility. Results of the study summarized herein suggest design of a capillary barrier which can reduce a recharge rate of 0.1 cm/yr by one or two orders of magnitude seems feasible for both concepts. A benchmark comparison of the unit cell model against a full facility model shows comparable predictive accuracy in less than one percent of the computer time. Results suggest that model parameters include capillary barrier performance, inter-canister spacing, rate of moisture withdrawal due to glass corrosion, contaminant inventory, and the well interceptor factor. It is also important that variations of waste form hydraulic parameters suggest that transport through the waste form is dominated by diffusion

  2. Abscisic Acid Accumulation in Spinach Leaf Slices in the Presence of Penetrating and Nonpenetrating Solutes 1

    Science.gov (United States)

    Creelman, Robert A.; Zeevaart, Jan A. D.

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation. When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO3, 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage). PMID:16664022

  3. Abscisic Acid accumulation in spinach leaf slices in the presence of penetrating and nonpenetrating solutes.

    Science.gov (United States)

    Creelman, R A; Zeevaart, J A

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation.When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO(3), 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage).

  4. An assessment of the number of CT slices necessary to plan breast radiotherapy

    International Nuclear Information System (INIS)

    Vincent, D.; Beckham, W.; Delaney, G.

    1999-01-01

    The aim of this study was to evaluate the number of CT slices required to produce satisfactory dose distribution for tangential field irradiation of the chest wall and breast and to assess correlation of this with the volume of breast tissue treated. We conclude that a single-slice plan is unsatisfactory in providing sufficient information about the dose variation across the treatment volume and that ideally a 3D plan with DVHs should be produced. If the required data is unavailable then a minimum of three slices should be used as an approximation. We also propose a software tool for treatment planning systems, which calculates the percentage of the total PTV having dose outside the ICRU 50 radiation dose distribution homogeneity guideline range

  5. Organotypic hippocampal slice culture from the adult mouse brain: a versatile tool for translational neuropsychopharmacology.

    Science.gov (United States)

    Kim, Hyunjeong; Kim, Eosu; Park, Minsun; Lee, Eun; Namkoong, Kee

    2013-03-05

    One of the most significant barriers towards translational neuropsychiatry would be an unavailability of living brain tissues. Although organotypic brain tissue culture could be a useful alternative enabling observation of temporal changes induced by various drugs in living brain tissues, a proper method to establish a stable organotypic brain slice culture system using adult (rather than neonatal) hippocampus has been still elusive. In this study, we evaluated our simple method using the serum-free culture medium for successful adult organotypic hippocampal slice culture. Several tens of hippocampal slices from a single adult mouse (3-5 months old) were cultured in serum-free versus serum-containing conventional culture medium for 30 days and underwent various experiments to validate the effects of the existence of serum in the culture medium. Neither the excessive regression of neuronal viability nor metabolic deficiency was observed in the serum-free medium culture in contrast to the serum-containing medium culture. Despite such viability, newly generated immature neurons were scarcely detected in the serum-free culture, suggesting that the original neurons in the brain slice persist rather than being replaced by neurogenesis. Key structural features of in vivo neural tissue constituting astrocytes, neural processes, and pre- and post-synapses were also well preserved in the serum-free culture. In conclusion, using the serum-free culture medium, the adult hippocampal slice culture system will serve as a promising ex vivo tool for various fields of neuroscience, especially for studies on aging-related neuropsychiatric disorders or for high throughput screening of potential agents working against such disorders. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Feasibility study of 2D thick-slice MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Takeuchi, Miho; Higashimura, Kyouji; Komuro, Hiroyuki

    2000-01-01

    Conditions required to perform contrast MR digital subtraction angiography using a two-dimensional thick-slice high-speed gradient echo were investigated. The conditions in the phantom experiment included: slice profile, flip angle, imaging matrix, fat suppression, duration of IR pulse and frequency selectivity, flip angle of IR pulse and inversion time. Based on the results of the experiment, 2D thick-slice MRDSA was performed in volunteers. Under TR/TE=5.3-9/1.3-1.8 ms conditions, the requirements were a slice thick enough to include the target region, a flip angle of 10 degrees, and a phase matrix of 96 or more. Fat suppression was required for adipose-tissue-rich regions, such as the abdomen. The optimal conditions for applying the IR preparation pulse of the IR prepped fast gradient recalled echo as spectrally selective inversion recovery appeared to be: duration of IR pulse =20 ms, flip angle =100 degrees, and inversion time =40 ms. The authors concluded that it was feasible to perform 2D thick-slice MRDSA with time resolution within 1 second. (K.H.)

  7. Relationship between moisture content and electrical impedance of carrot slices during drying

    Science.gov (United States)

    Kertész, Ákos; Hlaváčová, Zuzana; Vozáry, Eszter; Staroňová, Lenka

    2015-01-01

    Electrical properties of food materials can give information about the inner structure and physiological state of biological tissues. Generally, the process of drying of fruits and vegetables is followed by weight loss. The aim of this study was to measure the impedance spectra of carrot slices during drying and to correlate impedance parameters to moisture content in different drying periods. Cylindrical slices were cut out from the carrot root along the axis. The slices were dried in a Venticell 111 air oven at 50°C. The weight of the slices was measured with a Denver SI-603 electronic analytical and precision balance. The weighing of the samples was performed every 30 min at the beginning of drying and every 60 min after the process. The moisture content of the samples was calculated on wet basis. The magnitude and phase angle of electrical impedance of the slices were measured with HP 4284A and 4285A precision LCR meters in the frequency range from 30 Hz to 1 MHz and from 75 kHz to 30 MHz, respectively, at voltage 1 V. The impedance measurement was performed after weighting. The change in the magnitude of impedance during drying showed a good correlation with the change in the moisture content.

  8. Organizing a complex transport while guaranteeing safety and transparency: the example of vitrified wastes sent back to Germany

    International Nuclear Information System (INIS)

    Krochmaluk, Julie; Lebrun, Marc; Delmestre, Alain; Barbey, Pierre; Bonvalot, Vanessa; Belleville, Didier; Rollinger, Patrice; Alter, Ulrich

    2012-01-01

    This chapter is made of several small articles entitled: - 'Les controles avant le depart du convoi franco-allemand' (Controls before the departure of the French-German convoy); - 'La supervision des transports de matieres radioactives: une approche extensive de la surete des operations' (The supervision of radioactive material transports: an extended approach of operation safety); - 'Le dispositif d'information du public sur le transport des substances radioactives mis en place par l'ASN' (The plan implemented by the ASN for public information on nuclear materials transport); - 'Le recours de l'ASN a l'expertise de l'ACRO sur le convoi de colis de dechets vitrifies vers l'Allemagne' (The appeal of the ASN to the ACRO's expertise on the vitrified parcel convoy to Germany); - 'La participation du collectif STOP-EPR a l'inspection de l'ASN du convoi de colis de dechets vitrifies vers l'Allemagne' (The participation of the STOP-EPR collective to the control by the ASN of the vitrified parcel convoy to Germany); - 'La securite et la surete: des valeurs que le Groupe SNCF partage' (Security and safety: values which are shared by the SNCF Group); - 'Le transport de matieres nucleaires entre la France et l'Allemagne au cours des 40 dernieres annees' (Transport of nuclear materials between France and Germany during the last 40 years). Addressing the case of vitrified wastes transported back to Germany, the articles indicate the controls performed in France before convoy departure, discuss the approach adopted for the safety of radioactive material transport, comment the management of public information by the ASN for such transports, comment the intervention of the ACRO (Association for the control of radioactivity in western France) on the request of the ASN and the participation of a collective group (STOP-EPR) to the inspection of a convoy, outline the commitment of the French Railways (SNCF) in terms of security and safety, and give a qualitative and quantitative

  9. Development of a bread slicing machine from locally sourced ...

    African Journals Online (AJOL)

    This paper presents the development of a bread slicing machine which is a mechanical device that is used for slicing bread instead of the crude cumbersome and unhygienic method of manual slicing of bread. In an attempt to facilitate the final processing of bread which is a common daily food requirement of most Nigerians ...

  10. Slice through an LHC focusing magnet

    CERN Multimedia

    Slice through an LHC superconducting quadrupole (focusing) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. Bringing beams into collision requires a precision comparable to making two knitting needles collide, launched from either side of the Atlantic Ocean.

  11. Velocity slice imaging for dissociative electron attachment

    Science.gov (United States)

    Nandi, Dhananjay; Prabhudesai, Vaibhav S.; Krishnakumar, E.; Chatterjee, A.

    2005-05-01

    A velocity slice imaging method is developed for measuring the angular distribution of fragment negative ions arising from dissociative electron attachment (DEA) to molecules. A low energy pulsed electron gun, a pulsed field ion extraction, and a two-dimensional position sensitive detector consisting of microchannel plates and a wedge-and-strip anode are used for this purpose. Detection and storage of each ion separately for its position and flight time allows analysis of the data offline for any given time slice, without resorting to pulsing the detector bias. The performance of the system is evaluated by measuring the angular distribution of O- from O2 and comparing it with existing data obtained using conventional technique. The capability of this technique in obtaining forward and backward angular distribution data is shown to have helped in resolving one of the existing problems in the electron scattering on O2.

  12. Survival, Fertilization and Developmental Rates of Cryotop-Vitrified Oocyte and Embryo Using Low Concentrated Cryoprotectants

    Directory of Open Access Journals (Sweden)

    A Roozbehi

    2012-10-01

    Full Text Available Background & Aim: The preserving embryos, the risk of multiple pregnancies, the existence of factors in stimulated uterine cycle, are important forces in perfecting embryo cryopreservation. The aim of current study was to assess Survival, Fertilization and Developmental Rates (SRs, FRs, DRs of the mouse oocytes and embryos using cryotop and low concentrated cryoprotectants solutions. Methods: Mouse C57BL/6 oocytes and embryos were collected. Oocytes SRs, FRs, DRs were recorded after cryotop-vitrification/ warming. As well as comparing fresh oocytes and embryos, the data obtained from experimental groups (exp. applying 1.25, 1.0, and 0.75 Molar (M CPAs were analyzed in comparison to those of exp. adopting 1.5 M CPAs (largely-used concentration of EthylenGlycol (EG and Dimethylsulphoxide (DMSO. Results: The data of oocytes exposed to 1.25 M CPAs were in consistency with those exposed to 1.5 M and control group in terms of SR, FR and DR. As fewer concentrations were applied, the more decreased SRs, FRs and DRs were obtained from other experimental groups. The results of embryos were exposed to 1.25 M and 1.0 M was close to those vitrified with 1.5 M and fresh embryos. The results of 0.75 M concentrated CPAs solutions were significantly lower than those of control, 1.5 M and 1.0 M treated groups. Conclusion: CPAs limited reduction to 1.25 M and 1.0 M instead of using 1.5 M, for oocyte and embryo cryotop-vitrification procedure may be a slight adjustment.

  13. NF-PRO research on a repository for vitrified waste and spent fuel

    International Nuclear Information System (INIS)

    Sneyers, A.

    2006-01-01

    NF-PRO is a four-year (2004-2007) Integrated Project supported by funding under the Sixth Research (EURATOM) Programme of the European Commission. NF-PRO is coordinated by SCK C EN and investigates key processes in the near-field of geological repositories for the disposal of high-level vitrified waste and spent nuclear fuel. The near-field of a geological repository consists of the area surrounding the waste packages and is composed of several engineered barriers that enclose and confine the disposed waste. These barriers include the waste form, the waste canisters, backfills, seals, plugs and the part of the host rock that has been modified by the excavation of the repository. In all repository designs under investigation within EU Member States, the near-field plays an important role in ensuring the overall safety of disposal: its principal function is to retain radionuclides over extended periods of time and to minimise their release from the waste to the host rock. The main objective of NF-PRO is to integrate European research on the near field with the aim of enhancing common understanding of the long-term changes taking place in a deep repository. NF-PRO assesses how these changes affect the containment of the disposed radioactive waste. Knowledge generated by the project can be applied in waste management programmes to optimise repository designs and to make barriers functional and resource-efficient. The integration of results from detailed process studies in assessments on the overall near-field system performance is a key objective of NF-PRO. The level of integration envisaged by NF-PRO has not yet been achieved in earlier research projects supported by the European Commission. Accordingly, NF PRO represents a major step forward in the establishing of the scientific and technical basis for geological disposal and the safe management of radioactive wastes

  14. Retention of 137Cs and 90Sr by mineral sorbents surrounding vitrified nuclear waste

    International Nuclear Information System (INIS)

    Lyon, K.E.; Patterson, R.J.

    1985-01-01

    In June 1960, twenty-five 14-cm diameter hemispheres of vitrified nuclear waste (glass blocks) were buried in a shallow sand aquifer in the lower Perch Lake Basin, Chalk River Nuclear Laboratories, Ontario, Canada. Almost all leaching of the glass blocks occurred during the first 18 months of emplacement, and consequently the burial experiment approximated a single-injection source of 137 Cs and 90 Sr. After about 11 years, most of the 90 Sr that was released had been advected and dispersed from the site, whereas the bulk of the 137 Cs had travelled no more than 0.3 m from the blocks. Three piezometers were installed and five cores of sediment were collected at the glass block site in 1978. Mineralogically pure segregates of sand grains were prepared by hand and characterized using binocular, petrographic and scanning electron microscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy. A technique also was developed to measure very low levels of 137 Cs and 90 Sr by counting small (10-100 mg) sediment samples directly with a thin window, flow proportional counter. Results show that sand-sized grains of altered biotite (biotite-vermiculite), biotite, muscovite, hornblende and serictized feldspar are able to retain 137 Cs over a period of 18 years, and that grains of biotite-vermiculite, biotite and hematite-bearing feldspar (largely microline) can retain low levels of 90 Sr over the same period of time. The amounts of 137 Cs and 90 Sr sorbed by the mineral grains ranged from undetectable levels to approximately 380 and 35 becquerels/gram sediment, respectively. This report contains the complete series of mineral segregates ranked on a weight basis according to the amounts of retained 137 Cs and 90 Sr. Ground-water quality data indicate that none of the retention is the result of the precipitation of strontium or cesium minerals

  15. A Novel Slicing Method for Thin Supercapacitors.

    Science.gov (United States)

    Sun, Hao; Fu, Xuemei; Xie, Songlin; Jiang, Yishu; Guan, Guozhen; Wang, Bingjie; Li, Houpu; Peng, Huisheng

    2016-08-01

    Thin and flexible supercapacitors with low cost and individual variation are fabricated by a new and efficient slicing method. Tunable output voltage and energy can be realized with a high specific capacitance of 248.8 F g(-1) or 150.8 F cm(-3) , which is well maintained before and after bending. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Slice of a LEP bending magnet

    CERN Multimedia

    This is a slice of a LEP dipole bending magnet, made as a concrete and iron sandwich. The bending field needed in LEP is small (about 1000 Gauss), equivalent to two of the magnets people stick on fridge doors. Because it is very difficult to keep a low field steady, a high field was used in iron plates embedded in concrete. A CERN breakthrough in magnet design, LEP dipoles can be tuned easily and are cheaper than conventional magnets.

  17. Advanced separation and transmutation, long dated behavior of vitrified wastes: 15 years of scientific researches; Separation poussee et transmutation, comportement a long terme des dechets vitrifies: 15 ans d'avancees scientifiques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-02-15

    This report presents the results after 15 years of researches at the Cea, concerning the separation and transmutation of radioactive wastes and the conditioning and the long time storage of wastes at the surface. These researches were asked in the framework of the Bataille law. The first part devoted to the transmutation and separation of ling life radioactive elements presents the challenges, the advanced separation, the transmutation and the evaluation of the researches. The second part devoted to the long dated storage discusses the high activity wastes vitrification, the behavior of the vitrified wastes packages after thousand years, the international researches and the evaluation of the researches. (A.L.B.)

  18. RETROSPECTIVE DETECTION OF INTERLEAVED SLICE ACQUISITION PARAMETERS FROM FMRI DATA

    Science.gov (United States)

    Parker, David; Rotival, Georges; Laine, Andrew; Razlighi, Qolamreza R.

    2015-01-01

    To minimize slice excitation leakage to adjacent slices, interleaved slice acquisition is nowadays performed regularly in fMRI scanners. In interleaved slice acquisition, the number of slices skipped between two consecutive slice acquisitions is often referred to as the ‘interleave parameter’; the loss of this parameter can be catastrophic for the analysis of fMRI data. In this article we present a method to retrospectively detect the interleave parameter and the axis in which it is applied. Our method relies on the smoothness of the temporal-distance correlation function, which becomes disrupted along the axis on which interleaved slice acquisition is applied. We examined this method on simulated and real data in the presence of fMRI artifacts such as physiological noise, motion, etc. We also examined the reliability of this method in detecting different types of interleave parameters and demonstrated an accuracy of about 94% in more than 1000 real fMRI scans. PMID:26161244

  19. Formation of alteration products during dissolution of vitrified ILW in a high-pH calcium-rich solution

    Energy Technology Data Exchange (ETDEWEB)

    Utton, C.A., E-mail: c.utton@sheffield.ac.uk [Immobilisation Science Laboratory, Department of Materials Science and Engineering, University of Sheffield, Sir Robert Hadfield Building, Mappin Street, Sheffield S1 3JD (United Kingdom); Hand, R.J.; Hyatt, N.C. [Immobilisation Science Laboratory, Department of Materials Science and Engineering, University of Sheffield, Sir Robert Hadfield Building, Mappin Street, Sheffield S1 3JD (United Kingdom); Swanton, S.W. [AMEC, B150, Thomson Avenue, Harwell Oxford, Didcot, Oxfordshire OX11 0QB (United Kingdom); Williams, S.J. [Nuclear Decommissioning Authority, NDA Harwell Office, Building 587, Curie Avenue, Harwell Oxford, Didcot OX11 0RH (United Kingdom)

    2013-11-15

    To simulate the possible disposition of a vitrified intermediate-level waste (ILW) in a cementitious environment within a geological disposal facility (GDF), the durability of a laboratory simulant ILW vitrified in a borosilicate glass in a saturated Ca(OH){sub 2} solution (pH ∼12.5) was measured. Both a low surface area to volume (SA/V) ratio (∼10 m{sup −1}) Materials Characterisation Center test 1 (MCC-1) and a high SA/V ratio (∼10,000 m{sup −1}) product consistency test type B (PCT-B) were used at 50 °C for up to 170 days. The formation of alteration layers and products was followed. The surfaces of the monoliths were analysed using SEM/EDX and showed the formation of magnesium-rich precipitates and distinct calcium silicate hydrate (CSH) precipitates. Cross sections showed the development of a calcium-rich alteration layer, which was observed from 14 days. The altered layer was up to 5 μm thick after 170 days and showed accumulation of zirconium, iron and magnesium and to a lesser extent aluminium, along with calcium and silicon. Based on comparison of the rate data, it is suggested that the presence of this layer may offer some protection to the underlying glass. However, the high SA/V ratio experiments showed resumed alteration after 56 days, indicating that the altered layer may not be protective in the long term (under accelerated conditions). The formation of a magnesium-containing smectite clay (likely saponite) in addition to CSH(II), a jennite-like CSH phase, were identified in the high SA/V experiment by X-ray diffraction after 170 days. These results suggest that calcium and magnesium have important roles in both the long and shorter-term durability of vitrified wastes exposed to high pH.

  20. Cosmetic micromanipulation of vitrified-warmed cleavage stage embryos does not improve ART outcomes: An ultrastructural study of fragments.

    Science.gov (United States)

    Safari, Somayyeh; Khalili, Mohammad Ali; Barekati, Zeinab; Halvaei, Iman; Anvari, Morteza; Nottola, Stefania A

    2017-09-01

    The aim was to study the ultrastructure of cytoplasmic fragments along with the effect of cosmetic micromanipulation (CM) on the morphology and development of vitrified-warmed embryos as well as assisted reproductive technology (ART) outcomes. A total of 96 frozen embryo transfer (FET) cycles were included in this prospective randomized study. They were divided into three groups of CM (n=32), sham (n=32) and control (n=32). In the CM group, the vitrified- warmed embryos were subjected to fragments and coarse granules removal (cosmetic micromanipulation) after laser assisted zona hatching (LAH); sham group subjected only to LAH and no intervention was taken for the control group. Fragmented embryo was evaluated by transmission electron microscopy (TEM). Significant improvement was observed in the morphological parameters, such as fragmentation degrees, evenness of the blastomeres and embryo grade during the subsequent development, after applying cosmetic micromanipulation, when compared to sham or control groups (P=0.00001). However, there were no differences in the clinical outcomes amongst the three studied groups e.g. the rates of clinical, ongoing and multiple pregnancies, implantation, delivery and live birth. In fine structure view, fragments exhibited uniform cytoplasmic texture containing majority of organelles that were observed in normal blastomeres including mitochondria. In conclusion, application of cosmetic micromanipulation in low-grade vitrified-warmed embryos showed significant improvement on embryo morphology parameters; however, did not result in noticeable improvements in clinical outcomes of the patients undergoing ART program. In addition, embryo vitrification had no adverse effects on fine structure of the fragments. Copyright © 2017 Society for Biology of Reproduction & the Institute of Animal Reproduction and Food Research of Polish Academy of Sciences in Olsztyn. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  1. Comments on a paper tilted 'The sea transport of vitrified high-level radioactive wastes: Unresolved safety issues'

    International Nuclear Information System (INIS)

    Sprung, J.L.; McConnell, P.E.; Nigrey, P.J.; Ammerman, D.J.

    1997-05-01

    The cited paper estimates the consequences that might occur should a purpose-built ship transporting Vitrified High Level Waste (VHLW) be involved in a severe collision that causes the VHLW canisters in one Type-B package to spill onto the floor of a major ocean fishing region. Release of radioactivity from VHLW glass logs, failure of elastomer cask seals, failure of VHLW canisters due to stress corrosion cracking (SCC), and the probabilities of the hypothesized accident scenario, of catastrophic cask failure, and of cask recovery from the sea are all discussed

  2. Evaluation of the safety of vitrified high level waste shipments from UK to continental Europe by sea

    International Nuclear Information System (INIS)

    Lange, F.; Fett, H.; Hormann, E.; Rowekamp, M.; Elston, B.; Slawson, G.; Cheshire, R.; Schneider, T.; Raffestin, D.

    1998-10-01

    This document, prepared in the framework of a study for the European Commission in collaboration with the GRS (Germany and BNFL (United Kingdom), relates to the evaluation of the safety associated to the maritime transport of vitrified wastes from the United Kingdom towards Europe. With this intention, a travel of 1000 nautical miles (1852 km) was considered and a detailed analysis of the boat used by BNFL has been realized in order to elaborate a fault tree, for scenarios able to generate mechanical and thermal stresses significant on the transport packages (type B-packages). (A.L.B.)

  3. A Review and Analysis of European Industrial Experience in Handling LWR Spent Fuel and Vitrified High-Level Waste

    Energy Technology Data Exchange (ETDEWEB)

    Blomeke, J.O.

    2001-07-10

    The industrial facilities that have been built or are under construction in France, the United Kingdom, Sweden, and West Germany to handle light-water reactor (LWR) spent fuel and canisters of vitrified high-level waste before ultimate disposal are described and illustrated with drawings and photographs. Published information on the operating performance of these facilities is also given. This information was assembled for consideration in planning and design of similar equipment and facilities needed for the Federal Waste Management System in the United States.

  4. Fresh Slice Self-Seeding and Fresh Slice Harmonic Lasing at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.W. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2018-04-01

    We present results from the successful demonstration of fresh slice self-seeding at the Linac Coherent Light Source (LCLS).* The performance is compared with SASE and regular self-seeding at photon energy of 5.5 keV, resulting in a relative average brightness increase of a factor of 12 and a factor of 2 respectively. Following this proof-of-principle we discuss the forthcoming plans to use the same technique** for fresh slice harmonic lasing in an upcoming experiment. The demonstration of fresh slice harmonic lasing provides an attractive solution for future XFELs aiming to achieve high efficiency, high brightness X-ray pulses at high photon energies (>12 keV).***

  5. Experimental demonstration of spectrum-sliced elastic optical path network (SLICE).

    Science.gov (United States)

    Kozicki, Bartłomiej; Takara, Hidehiko; Tsukishima, Yukio; Yoshimatsu, Toshihide; Yonenaga, Kazushige; Jinno, Masahiko

    2010-10-11

    We describe experimental demonstration of spectrum-sliced elastic optical path network (SLICE) architecture. We employ optical orthogonal frequency-division multiplexing (OFDM) modulation format and bandwidth-variable optical cross-connects (OXC) to generate, transmit and receive optical paths with bandwidths of up to 1 Tb/s. We experimentally demonstrate elastic optical path setup and spectrally-efficient transmission of multiple channels with bit rates ranging from 40 to 140 Gb/s between six nodes of a mesh network. We show dynamic bandwidth scalability for optical paths with bit rates of 40 to 440 Gb/s. Moreover, we demonstrate multihop transmission of a 1 Tb/s optical path over 400 km of standard single-mode fiber (SMF). Finally, we investigate the filtering properties and the required guard band width for spectrally-efficient allocation of optical paths in SLICE.

  6. Induksi Ginogenesis melalui Kultur Multi Ovule Slice dan Kultur Ovary Slice Dianthus chinensis

    Directory of Open Access Journals (Sweden)

    Suskandari Kartikaningrum

    2013-10-01

    Full Text Available Callus induction was studied in five genotypes of Dianthus chinensis using 2.4 D and NAA. Calluses can be obtainedfrom unfertilized ovule culture and ovary culture. The aim of the research was to study gynogenic potential and responseof Dianthus chinensis through ovule slice and ovary slice culture for obtaining haploid plants. Five genotypes of Dianthuschinensis and five media were used in ovule slice culture and two genotypes and three medium were used in ovary culture.Flower buds in the 7th stage were incubated for the purpose of dark pre-treatment at 4 oC for one day. Ovules and ovaries wereisolated and cultured in induction medium. Cultures were incubated for the purpose of dark pre-treatment at 4 oC for seven days, followed by 25 oC light incubation. The result showed that 2.4D was better than NAA in inducing callus. Percentage of regenerated calluses were produced in V11, V13 and V15 genotypes in M7 medium (MS + 2 mg L-1 2.4D + 1 mg L-1 BAP + 30 g L-1 sucrose and M10 medium (MS + 1 mg L-1 2.4D + 1 mg L-1 BAP + 20 g L-1 sucrose. All calluses originated from ovule and ovary cultures flowered prematurely. Double haploid (V11-34 were obtained from ovule slice culture based on PER (peroksidase and EST (esterase isoenzym marker.Keywords: ovule slice culture, ovary slice culture, callus, Dianthus sp., haploid

  7. Dopaminergic Immunofluorescence Studies in Kidney Tissue.

    Science.gov (United States)

    Gildea, J J; Van Sciver, R E; McGrath, H E; Kemp, B A; Jose, P A; Carey, R M; Felder, R A

    2017-01-01

    The kidney is a highly integrated system of specialized differentiated cells that are responsible for fluid and electrolyte balance in the body. While much of today's research focuses on isolated nephron segments or cells from nephron segments grown in tissue culture, an often overlooked technique that can provide a unique view of many cell types in the kidney is slice culture. Here, we describe techniques that use freshly excised kidney tissue from rats to perform a variety of experiments shortly after isolating the tissue. By slicing the rat kidney in a "bread loaf" format, multiple studies can be performed on slices from the same tissue in parallel. Cryosectioning and staining of the tissue allow for the evaluation of physiological or biochemical responses in a wide variety of specific nephron segments. The procedures described within this chapter can also be extended to human or mouse kidney tissue.

  8. Antibrowning and antimicrobial properties of sodium acid sulfate in apple slices.

    Science.gov (United States)

    Fan, Xuetong; Sokorai, Kimberly J B; Liao, Ching-Hsing; Cooke, Peter; Zhang, Howard Q

    2009-01-01

    There are few available compounds that can both control browning and enhance microbial safety of fresh-cut fruits. In the present study, the antibrowning ability of sodium acid sulfate (SAS) on "Granny Smith" apple slices was first investigated in terms of optimum concentration and treatment time. In a separate experiment, the apple slices were treated with water or 3% of SAS, calcium ascorbate, citric acid, or acidified calcium sulfate for 5 min. Total plate count, color, firmness, and tissue damage were assessed during a 21-d storage at 4 degrees C. Results showed that the efficacy of SAS in inhibiting browning of apple slices increased with increasing concentration. A minimum 3% of SAS was needed to achieve 14 d of shelf life. Firmness was not significantly affected by SAS at 3% or lower concentrations. Antibrowning potential of SAS was similar for all treatment times ranging from 2 to 10 min. However, SAS caused some skin discoloration of apple slices. When cut surface of apple slices were stained with a fluorescein diacetate solution, tissue damage could be observed under a microscope even though visual damage was not evident. Among the antibrowning agents tested, SAS was the most effective in inhibiting browning and microbial growth for the first 14 d. Total plate count of samples treated with 3% SAS was significantly lower than those treated with calcium ascorbate, a commonly used antibrowning agent. Our results suggested that it is possible to use SAS to control browning while inhibiting the growth of microorganisms on the apple slices if the skin damage can be minimized. Practical Application: Fresh-cut apples have emerged as one of the popular products in restaurants, schools, and food service establishments as more consumers demand fresh, convenient, and nutritious foods. Processing of fresh-cut apples induces mechanical damage to the fruit and exposes apple tissue to air, resulting in the development of undesirable tissue browning. The fresh

  9. Geochemical and petrographic studies and the relationships to durability and leach resistance of vitrified products from the in situ vitrification process

    International Nuclear Information System (INIS)

    Timmons, D.M.; Thompson, L.E.

    1996-01-01

    Soil and sludge contaminated with hazardous and radioactive materials from sites in the United States and Australia were vitrified using in situ vitrification. Some of the resulting products were subjected to detailed geochemical, leach and durability testing using a variety of analytical techniques. The leach resistance and durability performance was compared to that of vitrified high level waste with borosilicate composition. Particular attention was given to crystallization behavior, the effects of crystallization on residual melt chemistry and how crystallization influences the behavior of contaminant ions. The results of this work show that the vitrified material studied has superior chemical durability and leach resistance relative to typical borosilicate waste glasses. Crystallization behavior was variable depending upon melt chemistry and cooling history. Crystallization was not observed to adversely affect chemical durability or leach resistance

  10. Birth of normal infants after transfer of embryos that were twice vitrified/warmed at cleavage stages: report of two cases.

    Science.gov (United States)

    Valle, Marcello; Guimarães, Fernando; Cavagnoli, Melissa; Sampaio, Marcos; Geber, Selmo

    2012-12-01

    The role of cryopreservation in assisted reproductive technology programs has increased within the last years allowing the transfer of a limited number of embryos and the storage of the remaining for future use. The reduction in the number of transferred embryos decreases the frequency of multiple pregnancy rates and of ovarian hyperstimulation syndrome while the cumulative pregnancy rate can be maximized. Moreover, as not all embryos will survive the warming process more cleavage stage embryos are warmed to improve selection for transfer. Therefore, surplus good quality cleavage stage embryos and/or blastocysts must be re-vitrified for further transfer to achieve pregnancy. To our knowledge, there have been no reports demonstrating that human embryos can be successfully vitrified/warmed twice at the cleavage stage. Thus we report two successful pregnancies and deliveries of healthy babies after transfer of embryos that were twice vitrified/warmed at 2-4 cells stage. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Time efficient whole-brain coverage with MR Fingerprinting using slice-interleaved echo-planar-imaging.

    Science.gov (United States)

    Rieger, Benedikt; Akçakaya, Mehmet; Pariente, José C; Llufriu, Sara; Martinez-Heras, Eloy; Weingärtner, Sebastian; Schad, Lothar R

    2018-04-27

    Magnetic resonance fingerprinting (MRF) is a promising method for fast simultaneous quantification of multiple tissue parameters. The objective of this study is to improve the coverage of MRF based on echo-planar imaging (MRF-EPI) by using a slice-interleaved acquisition scheme. For this, the MRF-EPI is modified to acquire several slices in a randomized interleaved manner, increasing the effective repetition time of the spoiled gradient echo readout acquisition in each slice. Per-slice matching of the signal-trace to a precomputed dictionary allows the generation of T 1 and T 2 * maps with integrated B 1 + correction. Subsequent compensation for the coil sensitivity profile and normalization to the cerebrospinal fluid additionally allows for quantitative proton density (PD) mapping. Numerical simulations are performed to optimize the number of interleaved slices. Quantification accuracy is validated in phantom scans and feasibility is demonstrated in-vivo. Numerical simulations suggest the acquisition of four slices as a trade-off between quantification precision and scan-time. Phantom results indicate good agreement with reference measurements (Difference T 1 : -2.4 ± 1.1%, T 2 *: -0.5 ± 2.5%, PD: -0.5 ± 7.2%). In-vivo whole-brain coverage of T 1 , T 2 * and PD with 32 slices was acquired within 3:36 minutes, resulting in parameter maps of high visual quality and comparable performance with single-slice MRF-EPI at 4-fold scan-time reduction.

  12. Electrophysiology of Hypothalamic Magnocellular Neurons In vitro: A Rhythmic Drive in Organotypic Cultures and Acute Slices.

    Science.gov (United States)

    Israel, Jean-Marc; Oliet, Stéphane H; Ciofi, Philippe

    2016-01-01

    Hypothalamic neurohormones are released in a pulsatile manner. The mechanisms of this pulsatility remain poorly understood and several hypotheses are available, depending upon the neuroendocrine system considered. Among these systems, hypothalamo-neurohypophyseal magnocellular neurons have been early-considered models, as they typically display an electrical activity consisting of bursts of action potentials that is optimal for the release of boluses of the neurohormones oxytocin and vasopressin. The cellular mechanisms underlying this bursting behavior have been studied in vitro, using either acute slices of the adult hypothalamus, or organotypic cultures of neonatal hypothalamic tissue. We have recently proposed, from experiments in organotypic cultures, that specific central pattern generator networks, upstream of magnocellular neurons, determine their bursting activity. Here, we have tested whether a similar hypothesis can be derived from in vitro experiments in acute slices of the adult hypothalamus. To this aim we have screened our electrophysiological recordings of the magnocellular neurons, previously obtained from acute slices, with an analysis of autocorrelation of action potentials to detect a rhythmic drive as we recently did for organotypic cultures. This confirmed that the bursting behavior of magnocellular neurons is governed by central pattern generator networks whose rhythmic drive, and thus probably integrity, is however less satisfactorily preserved in the acute slices from adult brains.

  13. Electrophysiology of hypothalamic magnocellular neurons in vitro: a rhythmic drive in organotypic cultures and acute slices

    Directory of Open Access Journals (Sweden)

    Jean-Marc eIsrael

    2016-03-01

    Full Text Available Hypothalamic neurohormones are released in a pulsatile manner. The mechanisms of this pulsatility remain poorly understood and several hypotheses are available, depending upon the neuroendocrine system considered. Among these systems, hypothalamo-neurohypophyseal magnocellular neurons have been early-considered models, as they typically display an electrical activity consisting of bursts of action potentials that is optimal for the release of boluses of the neurohormones oxytocin and vasopressin. The cellular mechanisms underlying this bursting behavior have been studied in vitro, using either acute slices of the adult hypothalamus, or organotypic cultures of neonatal hypothalamic tissue. We have recently proposed, from experiments in organotypic cultures, that specific central pattern generator networks, upstream of magnocellular neurons, determine their bursting activity. Here, we have tested whether a similar hypothesis can be derived from in vitro experiments in acute slices of the adult hypothalamus. To this aim we have screened our electrophysiological recordings of the magnocellular neurons, previously obtained from acute slices, with an analysis of autocorrelation of action potentials to detect a rhythmic drive as we recently did for organotypic cultures. This confirmed that the bursting behavior of magnocellular neurons is governed by central pattern generator networks whose rhythmic drive, and thus probably integrity, is however less satisfactorily preserved in the acute slices from adult brains.

  14. A concept for a station for the encapsulation of vitrified highly radioactive waste into containers for final disposal

    International Nuclear Information System (INIS)

    Anon

    1984-09-01

    The report presents a concept and plans for a station for the encapsulation of vitrified highly radioactive waste into containers for final disposal. The process steps, the layout of the station, the main components of equipment and the sequence of operations under normal conditions are described. The station is designed for vitrified waste from reprocessing. The volume of the waste packages is 150 l, and each package contains the equivalent of 1.33 tonne HM of fuel. The radionuclide activity of the waste corresponds to spent fuel with a decay time of 40 years from discharge from the reactor. It is assumed that after transport under normal conditions the steel shell enclosing the waste is gastight and its surface is free of contamination. The containers for final disposal are made of cast steel and have the form of hollow cylinders with hemispherical ends; their overall length is 2 m and their overall diameter 0.94 m. The station is so designed that the whole procedure, from supply of the transport containers containing the waste to the delivery of the full final disposal containers, is carried out by remote control behind radiation screens in an area isolated from the environment. Containers that do not fulfill the quality control requirements can be improved or repaired in a special rework cell without interfering with the further normal operation of the plant. (author)

  15. High capacity cask (TN28V) and International Transport System for the return shipment of vitrified high activity wastes

    International Nuclear Information System (INIS)

    Sert, G.; Savornin, B.; Rouquette, Y.

    1989-01-01

    The reprocessing of spent fuel generates different kinds of wastes. Among them fission products and non fissile actinides represent 98% of the radioactivity; these wastes are separated, concentrated, mixed with molten glass and poured into stainless steel containers. For political reasons, it is necessary to return these vitrified high activity wastes to the foreign countries which have decided to have their spent fuel reprocessed in France. So the transport of vitrified waste is vital for both the reprocessor and the utilities that have trusted the reprocessor and this operation has to be securely performed to give satisfaction to all concerned particles. For that reason Cogema will control the whole transport activity from La Hague plants to the receiving facilities of the customers. Therefore cogema will be responsible of the transport whatever the cask type (transport or storage) and will subcontract the transport operation to experienced companies such as Transnucleaire, PNTL or NTL, who will act on behalf of Cogema. Cogema will be the owner of the transport casks while the storage casks will normally be owned by the customers. Both cask types will of course have to comply with the requirements of La Hague, as published by Cogema

  16. Preservation of human ovarian follicles within tissue frozen by vitrification in a xeno-free closed system using only ethylene glycol as a permeating cryoprotectant.

    Science.gov (United States)

    Sheikhi, Mona; Hultenby, Kjell; Niklasson, Boel; Lundqvist, Monalill; Hovatta, Outi

    2013-07-01

    To study the preservation of follicles within ovarian tissue vitrified using only one or a combination of three permeating cryoprotectants. Experimental study. University hospital. Ovarian tissue was donated by consenting women undergoing elective cesarean section. Ovarian tissue was vitrified in closed sealed vials using either a combination of dimethyl sulfoxide, 1,2-propanediol, and ethylene glycol (EG), or only EG as permeating cryoprotectants. Ovarian tissue was vitrified with the use of two vitrification methods. Tissue from the same donor was used for comparison of two different solutions. The morphology of the follicles was evaluated after vitrification, warming, and culture by light microscopy and transmission electron microscopy. Apoptosis was assessed by immunohistochemistry for active caspase-3 in fresh and vitrified tissue. Light and electron microscopic analysis showed equally well preserved morphology of oocytes, granulosa cells, and ovarian stroma when either of the vitrification solutions was used. No apoptosis was observed in primordial and primary follicles. Using only EG as a permeating cryoprotectant in a closed tube gives as good ultrastructural preservation of ovarian follicles as a more complicated system using several cryoprotectants. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  17. Comparison of sliced lungs with whole lung sets for a torso phantom measured with Ge detectors using Monte Carlo simulations (MCNP).

    Science.gov (United States)

    Kramer, Gary H; Guerriere, Steven

    2003-02-01

    Lung counters are generally used to measure low energy photons (<100 keV). They are usually calibrated with lung sets that are manufactured from a lung tissue substitute material that contains homogeneously distributed activity; however, it is difficult to verify either the activity in the phantom or the homogeneity of the activity distribution without destructive testing. Lung sets can have activities that are as much as 25% different from the expected value. An alternative method to using whole lungs to calibrate a lung counter is to use a sliced lung with planar inserts. Experimental work has already indicated that this alternative method of calibration can be a satisfactory substitute. This work has extended the experimental study by the use of Monte Carlo simulation to validate that sliced and whole lungs are equivalent. It also has determined the optimum slice thicknesses that separate the planar sources in the sliced lung. Slice thicknesses have been investigated in the range of 0.5 cm to 9.0 cm and at photon energies from 17 keV to 1,000 keV. Results have shown that there is little difference between sliced and whole lungs at low energies providing that the slice thickness is 2.0 cm or less. As the photon energy rises the slice thickness can increase substantially with no degradation on equivalence.

  18. Mixed time slicing in path integral simulations

    International Nuclear Information System (INIS)

    Steele, Ryan P.; Zwickl, Jill; Shushkov, Philip; Tully, John C.

    2011-01-01

    A simple and efficient scheme is presented for using different time slices for different degrees of freedom in path integral calculations. This method bridges the gap between full quantization and the standard mixed quantum-classical (MQC) scheme and, therefore, still provides quantum mechanical effects in the less-quantized variables. Underlying the algorithm is the notion that time slices (beads) may be 'collapsed' in a manner that preserves quantization in the less quantum mechanical degrees of freedom. The method is shown to be analogous to multiple-time step integration techniques in classical molecular dynamics. The algorithm and its associated error are demonstrated on model systems containing coupled high- and low-frequency modes; results indicate that convergence of quantum mechanical observables can be achieved with disparate bead numbers in the different modes. Cost estimates indicate that this procedure, much like the MQC method, is most efficient for only a relatively few quantum mechanical degrees of freedom, such as proton transfer. In this regime, however, the cost of a fully quantum mechanical simulation is determined by the quantization of the least quantum mechanical degrees of freedom.

  19. Thin-Slice Measurement of Wisdom

    Directory of Open Access Journals (Sweden)

    Chao S. Hu

    2017-08-01

    Full Text Available Objective Measurement of Wisdom within a short period of time is vital for both the public interest (e.g., understanding a presidential election and research (e.g., testing factors that facilitate wisdom development. A measurement of emotion associated with wisdom would be especially informative; therefore, a novel Thin-Slice measurement of wisdom was developed based on the Berlin Paradigm. For about 2 min, participants imagined the lens of a camera as the eyes of their friend/teacher whom they advised about a life dilemma. Verbal response and facial expression were both recorded by a camera: verbal responses were then rated on both the Berlin Wisdom criteria and newly developed Chinese wisdom criteria; facial expressions were analyzed by the software iMotion FACET module. Results showed acceptable inter-rater and inter-item reliability for this novel paradigm. Moreover, both wisdom ratings were not significantly correlated with Social desirability, and the Berlin wisdom rating was significantly negatively correlated with Neuroticism; feeling of surprise was significantly positively correlated with both wisdom criteria ratings. Our results provide the first evidence of this Thin-slice Wisdom Paradigm’s reliability, its immunity to social desirability, and its validity for assessing candidates’ wisdom within a short timeframe. Although still awaiting further development, this novel Paradigm contributes to an emerging Universal Wisdom Paradigm applicable across cultures.

  20. Comparison of 640-Slice Multidetector Computed Tomography Versus 32-Slice MDCT for Imaging of the Osteo-odonto-keratoprosthesis Lamina.

    Science.gov (United States)

    Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C

    2015-08-01

    To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.

  1. Innovative methods to study human intestinal drug metabolism in vitro : Precision-cut slices compared with Ussing chamber preparations

    NARCIS (Netherlands)

    van de Kerkhof, Esther G.; Ungell, Anna-Lena B.; Sjoberg, Asa K.; de Jager, Marina H.; Hilgendorf, Constanze; de Graaf, Inge A. M.; Groothuis, Geny M. M.

    2006-01-01

    Predictive in vitro methods to investigate drug metabolism in the human intestine using intact tissue are of high importance. Therefore, we studied the metabolic activity of human small intestinal and colon slices and compared it with the metabolic activity of the same human intestinal segments

  2. Human precision-cut liver slices as a model to test antifibrotic drugs in the early onset of liver fibrosis

    NARCIS (Netherlands)

    Westra, Inge M.; Mutsaers, Henricus A. M.; Luangmonkong, Theerut; Hadi, Mackenzie; Oosterhuis, Dorenda; de Jong, Koert P.; Groothuis, Geny M. M.; Olinga, Peter

    Liver fibrosis is the progressive accumulation of connective tissue ultimately resulting in loss of organ function. Currently, no effective antifibrotics are available due to a lack of reliable human models. Here we investigated the fibrotic process in human precision-cut liver slices (PCLS) and

  3. Tumor Slice Culture: A New Avatar in Personalized Oncology

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-16-1-0149 TITLE: Tumor Slice Culture: A New Avatar in Personalized Oncology PRINCIPAL INVESTIGATOR: Raymond Yeung...CONTRACT NUMBER Tumor Slice Culture: A New Avatar in Personalized Oncology 5b. GRANT NUMBER W81XWH-16-1-0149 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...10 Annual Report 2017: Tumor Slice Culture: A new avatar for personalized oncology 1. INTRODUCTION: The goal of this research is to advance our

  4. Gravitational collapse of charged dust shell and maximal slicing condition

    International Nuclear Information System (INIS)

    Maeda, Keiichi

    1980-01-01

    The maximal slicing condition is a good time coordinate condition qualitatively when pursuing the gravitational collapse by the numerical calculation. The analytic solution of the gravitational collapse under the maximal slicing condition is given in the case of a spherical charged dust shell and the behavior of time slices with this coordinate condition is investigated. It is concluded that under the maximal slicing condition we can pursue the gravitational collapse until the radius of the shell decreases to about 0.7 x (the radius of the event horizon). (author)

  5. Thin slices of child personality: Perceptual, situational, and behavioral contributions.

    Science.gov (United States)

    Tackett, Jennifer L; Herzhoff, Kathrin; Kushner, Shauna C; Rule, Nicholas

    2016-01-01

    The present study examined whether thin-slice ratings of child personality serve as a resource-efficient and theoretically valid measurement of child personality traits. We extended theoretical work on the observability, perceptual accuracy, and situational consistency of childhood personality traits by examining intersource and interjudge agreement, cross-situational consistency, and convergent, divergent, and predictive validity of thin-slice ratings. Forty-five unacquainted independent coders rated 326 children's (ages 8-12) personality in 1 of 15 thin-slice behavioral scenarios (i.e., 3 raters per slice, for over 14,000 independent thin-slice ratings). Mothers, fathers, and children rated children's personality, psychopathology, and competence. We found robust evidence for correlations between thin-slice and mother/father ratings of child personality, within- and across-task consistency of thin-slice ratings, and convergent and divergent validity with psychopathology and competence. Surprisingly, thin-slice ratings were more consistent across situations in this child sample than previously found for adults. Taken together, these results suggest that thin slices are a valid and reliable measure to assess child personality, offering a useful method of measurement beyond questionnaires, helping to address novel questions of personality perception and consistency in childhood. (c) 2016 APA, all rights reserved).

  6. Influence of γ-irradiation on drying of slice potato

    International Nuclear Information System (INIS)

    Wang Jun; Chao Yan; Fu Junjie; Wang Jianping

    2001-01-01

    A new technology is introduced to dry food products by hot-air after pretreated by irradiation. The influence of different dosage of irradiation, temperature of hot air, thickness of the slice potato on the rate of dehydration temperature of irradiated potato were studied. A conclusion is reached that the 3 factors, irradiation dosage, hot-air temperature and thickness of slice potato, affect the rate of dehydration and temperature of slice potato. The higher the dosage is, the greater the rate of dehydration of potato becomes, and the higher the temperature of the slice potato gets. (authors)

  7. Evaluation of the precision-cut liver and lung slice systems for the study of induction of CYP1, epoxide hydrolase and glutathione S-transferase activities.

    Science.gov (United States)

    Pushparajah, Daphnee S; Umachandran, Meera; Plant, Kathryn E; Plant, Nick; Ioannides, Costas

    2007-02-28

    The principal objective was to ascertain whether precision-cut tissue slices can be used to evaluate the potential of chemicals to induce CYP1, epoxide hydrolase and glutathione S-transferase activities, all being important enzymes involved in the metabolism of polycyclic aromatic hydrocarbons. Precision-cut rat liver and lung slices were incubated with a range of benzo[a]pyrene concentrations for various time periods. A rise in the O-deethylation of ethoxyresorufin was seen in both liver and lung slices exposed to benzo[a]pyrene, which was accompanied by increased CYP1A apoprotein levels. Pulmonary CYP1B1 apoprotein levels and hepatic mRNA levels were similarly enhanced. Elevated epoxide hydrolase and glutathione S-transferase activities were also observed in liver slices following incubation for 24h; similarly, a rise in apoprotein levels of both enzymes was evident, peak levels occurring at the same time point. When mRNA levels were monitored, a rise in the levels of both enzymes was seen as early as 4h after incubation, but maximum levels were attained at 24 h. In lung slices, induction of epoxide hydrolase by benzo[a]pyrene was observed after a 24-h incubation, and at a concentration of 1 microM; a rise in apoprotein levels was seen at this time point. Glutathione S-transferase activity was not inducible in lung slices by benzo[a]pyrene but a modest increase was observed in hepatic slices. Collectively, these studies confirmed CYP1A induction in rat liver slices and established that CYP1B1 expression, and epoxide hydrolase and glutathione S-transferase activities are inducible in precision-cut tissue slices.

  8. Effect of composition variations on the long-term wasteform behavior of vitrified domestic waste incineration fly-ash purification residues

    International Nuclear Information System (INIS)

    Frugier, Pierre

    1999-01-01

    The effect of variations in the composition of fly-ash purification residue from incinerated domestic waste on the quality of the containment achieved by vitrification was investigated. Three main factors determine the long-term containment quality: the production of a vitrified wasteform, the occurrence of possible crystallization, and the key parameters of long-term alteration in aqueous media. Each of these aspects is described within a composition range defined by variations in the three major elements. (silicon, calcium and aluminum) and two groups of constituents (alkali metals and toxic elements). The silicon fraction in the fly-ash residue was found to be decisive: it is impossible to obtain a satisfactory vitrified wasteform below a given silicon concentration. Compounds with the lowest silica content also exhibited the greatest tendency to crystallize under the cooling conditions prevailing in industrial processes (the dominant crystallized phase is a melilite that occupies a significant fraction of the material and considerably modifies the alteration mechanisms). The initial alteration rate in pure water and the altered glass thickness measured in a closed system at an advanced stage of the dissolution reaction are both inversely related to the silicon concentration in the glass. Several types of long-term behavior were identified according to the composition range, the process conditions and the vitrified waste disposal scenario. Four distinct 'classes' of vitrified wasteform were defined for direct application in industrial processes. (author) [fr

  9. Targeting neurotransmitter receptors with nanoparticles in vivo allows single-molecule tracking in acute brain slices

    Science.gov (United States)

    Varela, Juan A.; Dupuis, Julien P.; Etchepare, Laetitia; Espana, Agnès; Cognet, Laurent; Groc, Laurent

    2016-03-01

    Single-molecule imaging has changed the way we understand many biological mechanisms, particularly in neurobiology, by shedding light on intricate molecular events down to the nanoscale. However, current single-molecule studies in neuroscience have been limited to cultured neurons or organotypic slices, leaving as an open question the existence of fast receptor diffusion in intact brain tissue. Here, for the first time, we targeted dopamine receptors in vivo with functionalized quantum dots and were able to perform single-molecule tracking in acute rat brain slices. We propose a novel delocalized and non-inflammatory way of delivering nanoparticles (NPs) in vivo to the brain, which allowed us to label and track genetically engineered surface dopamine receptors in neocortical neurons, revealing inherent behaviour and receptor activity regulations. We thus propose a NP-based platform for single-molecule studies in the living brain, opening new avenues of research in physiological and pathological animal models.

  10. Mathematical Modeling of Thin Layer Microwave Drying of Taro Slices

    Science.gov (United States)

    Kumar, Vivek; Sharma, H. K.; Singh, K.

    2016-03-01

    The present study investigated the drying kinetics of taro slices precooked in different medium viz water (WC), steam (SC) and Lemon Solution (LC) and dried at different microwave power 360, 540 and 720 W. Drying curves of all precooked slices at all microwave powers showed falling rate period along with a very short accelerating period at the beginning of the drying. At all microwave powers, higher drying rate was observed for LC slices as compared to WC and SC slices. To select a suitable drying curve, seven thin-layer drying models were fitted to the experimental data. The data revealed that the Page model was most adequate in describing the microwave drying behavior of taro slices precooked in different medium. The highest effective moisture diffusivity value of 2.11 × 10-8 m2/s was obtained for LC samples while the lowest 0.83 × 10-8 m2/s was obtained for WC taro slices. The activation energy (E a ) of LC taro slices was lower than the E a of WC and SC taro slices.

  11. Design and Development of a tomato Slicing Machine

    OpenAIRE

    Kamaldeen Oladimeji Salaudeen; Awagu E. F.

    2012-01-01

    Principle of slicing was reviewed and tomato slicing machine was developed based on appropriate technology. Locally available materials like wood, stainless steel and mild steel were used in the fabrication. The machine was made to cut tomatoes in 2cm thickness. The capacity of the machine is 540.09g per minute and its performance efficiency is 70%.

  12. Reevaluation of Vitrified High-Level Waste Form Criteria for Potential Cost Savings at the Defense Waste Processing Facility - 13598

    Energy Technology Data Exchange (ETDEWEB)

    Ray, J.W. [Savannah River Remediation (United States); Marra, S.L.; Herman, C.C. [Savannah River National Laboratory, Savannah River Site, Aiken, SC 29808 (United States)

    2013-07-01

    At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a durable borosilicate glass since 1996. Currently the DWPF has poured over 3,500 canisters, all of which are compliant with the U. S. Department of Energy's (DOE) Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS) and therefore ready to be shipped to a federal geologic repository for permanent disposal. Due to DOE petitioning to withdraw the Yucca Mountain License Application (LA) from the Nuclear Regulatory Commission (NRC) in 2010 and thus no clear disposal path for SRS canistered waste forms, there are opportunities for cost savings with future canister production at DWPF and other DOE producer sites by reevaluating high-level waste form requirements and compliance strategies and reducing/eliminating those that will not negatively impact the quality of the canistered waste form. (authors)

  13. Report on the joint USA-Germany drop test program for a vitrified high level waste cask

    International Nuclear Information System (INIS)

    Golliher, K.G.; Witt, C.R.; Wieser, K.E.

    1993-01-01

    A series of full-scale drop tests was performed on a ductile iron transport cask in a cooperative program between the US Department of Energy (DOE) and Bundesantalt fuer Materialpruefung (BAM) in Germany. The tests, which were performed at BAM's test facility located near Lehre, Germany, were performed on a prototype cask designed for transport of Vitrified High Level Waste (VHLW) canisters. The VHLW cask is a right circular cylinder with a diameter of 1156 mm and a height of 3454 cm, and weighs approximately 24.6 kg including its payload of a single VHLW canister. The drop tests were performed with a non-radioactive, prototype VHLW canister in the cavity. (J.P.N.)

  14. Reevaluation Of Vitrified High-Level Waste Form Criteria For Potential Cost Savings At The Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Ray, J. W.; Marra, S. L.; Herman, C. C.

    2013-01-01

    At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a durable borosilicate glass since 1996. Currently the DWPF has poured over 3,500 canisters, all of which are compliant with the U. S. Department of Energy's (DOE) Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS) and therefore ready to be shipped to a federal geologic repository for permanent disposal. Due to DOE petitioning to withdraw the Yucca Mountain License Application (LA) from the Nuclear Regulatory Commission (NRC) in 2010 and thus no clear disposal path for SRS canistered waste forms, there are opportunities for cost savings with future canister production at DWPF and other DOE producer sites by reevaluating high-level waste form requirements and compliance strategies and reducing/eliminating those that will not negatively impact the quality of the canistered waste form

  15. Neuropeptide processing in regional brain slices: Effect of conformation and sequence

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.W.; Bijl, W.A.; van Nispen, J.W.; Brendel, K.; Davis, T.P. (Univ. of Arizona, Tucson (USA))

    1990-05-01

    The central enzymatic stability of des-enkephalin-gamma-endorphin and its synthetic analogs (cycloN alpha 6, C delta 11)beta-endorphin-(6-17) and (Pro7, Lys(Ac)9)-beta-endorphin(6-17) was studied in vitro using a newly developed, regionally dissected rat brain slice, time course incubation procedure. Tissue slice viability was estimated as the ability of the brain slice to take up or release gamma-(3H)aminobutyric acid after high K+ stimulation. Results demonstrated stability of uptake/release up to 5 hr of incubation, suggesting tissue viability over this period. The estimated half-life of peptides based on the results obtained in our incubation protocol suggest that the peptides studied are metabolized at different rates in the individual brain regions tested. A good correlation exists between the high enzyme activity of neutral endopeptidase and the rapid degradation of des-enkephalin-gamma-endorphin and (cycloN alpha 6, C delata 11)beta-endorphin-(6-17) in caudate putamen. Proline substitution combined with lysine acetylation appears to improve resistance to enzymatic metabolism in caudate putamen and hypothalamus. However, cyclization of des-enkephalin-gamma-endorphin forming an amide bond between the alpha-NH2 of the N-terminal threonine and the gamma-COOH of glutamic acid did not improve peptide stability in any brain region tested. The present study has shown that the brain slice technique is a valid and unique approach to study neuropeptide metabolism in small, discrete regions of rat brain where peptides, peptidases and receptors are colocalized and that specific structural modifications can improve peptide stability.

  16. Thermoluminescence results on slices from a Hiroshima tile UHFSFT03

    International Nuclear Information System (INIS)

    Stoneham, Doreen

    1987-01-01

    As was reported at the May 1984 Utah thermoluminescence (TL) workshop, high fired tiles and porcelain fragments can be sliced into 200 μm sections with constant surface area. When conventional pre-dose measurements were carried out on these slices the doses evaluated were in good agreement with results obtained by other workers using conventional quartz separation techniques. There are several advantages in using slices. First, less sample is needed as about 50 consecutive slices can be cut from a block measuring typically 1 cm 2 cross section and 2 cm in length. There are no problems with securing grains to the plate or loss of grains during measurement. Hypothetically there is less damage to the grains when they are cut slowly under cold water than when they are crushed. The disadvantage is that other minerals besides quartz are present in the slice and the signal is weaker than that obtained using quartz inclusions

  17. Correlation of NTD-silicon rod and slice resistivity

    International Nuclear Information System (INIS)

    Wolverton, W.M.

    1984-01-01

    Neutron transmutation doped silicon is an electronic material which presents an opportunity to explore a high level of resistivity characterization. This is due to its excellent uniformity of dopant concentration. Appropriate resistivity measurements on the ingot raw material can be used as a predictor of slice resistivity. Correlation of finished NTD rod (i.e. ingot) resistivity to as-cut slice resistivity (after the sawing process) is addressed in the scope of this paper. Empirical data show that the shift of slice-center resistivity compared to rod-end center resistivity is a function of a new kind of rod radial-resistivity gradient. This function has two domains, and most rods are in domain ''A''. Correlating equations show how to significantly improve the prediction of slice resistivity of rods in domain ''A''. The new rod resistivity specifications have resulted in manufacturing economies in the production of NTD silicon slices

  18. A survey of program slicing for software engineering

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    This research concerns program slicing which is used as a tool for program maintainence of software systems. Program slicing decreases the level of effort required to understand and maintain complex software systems. It was first designed as a debugging aid, but it has since been generalized into various tools and extended to include program comprehension, module cohesion estimation, requirements verification, dead code elimination, and maintainence of several software systems, including reverse engineering, parallelization, portability, and reuse component generation. This paper seeks to address and define terminology, theoretical concepts, program representation, different program graphs, developments in static slicing, dynamic slicing, and semantics and mathematical models. Applications for conventional slicing are presented, along with a prognosis of future work in this field.

  19. RF slice profile effects in magnetic resonance fingerprinting.

    Science.gov (United States)

    Hong, Taehwa; Han, Dongyeob; Kim, Min-Oh; Kim, Dong-Hyun

    2017-09-01

    The radio frequency (RF) slice profile effects on T1 and T2 estimation in magnetic resonance fingerprinting (MRF) are investigated with respect to time-bandwidth product (TBW), flip angle (FA) level and field inhomogeneities. Signal evolutions are generated incorporating the non-ideal slice selective excitation process using Bloch simulation and matched to the original dictionary with and without the non-ideal slice profile taken into account. For validation, phantom and in vivo experiments are performed at 3T. Both simulations and experiments results show that T1 and T2 error from non-ideal slice profile increases with increasing FA level, off-resonance, and low TBW values. Therefore, RF slice profile effects should be compensated for accurate determination of the MR parameters. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  1. Characterization of cortical neuronal and glial alterations during culture of organotypic whole brain slices from neonatal and mature mice.

    Science.gov (United States)

    Staal, Jerome A; Alexander, Samuel R; Liu, Yao; Dickson, Tracey D; Vickers, James C

    2011-01-01

    Organotypic brain slice culturing techniques are extensively used in a wide range of experimental procedures and are particularly useful in providing mechanistic insights into neurological disorders or injury. The cellular and morphological alterations associated with hippocampal brain slice cultures has been well established, however, the neuronal response of mouse cortical neurons to culture is not well documented. In the current study, we compared the cell viability, as well as phenotypic and protein expression changes in cortical neurons, in whole brain slice cultures from mouse neonates (P4-6), adolescent animals (P25-28) and mature adults (P50+). Cultures were prepared using the membrane interface method. Propidium iodide labeling of nuclei (due to compromised cell membrane) and AlamarBlue™ (cell respiration) analysis demonstrated that neonatal tissue was significantly less vulnerable to long-term culture in comparison to the more mature brain tissues. Cultures from P6 animals showed a significant increase in the expression of synaptic markers and a decrease in growth-associated proteins over the entire culture period. However, morphological analysis of organotypic brain slices cultured from neonatal tissue demonstrated that there were substantial changes to neuronal and glial organization within the neocortex, with a distinct loss of cytoarchitectural stratification and increased GFAP expression (pglial limitans and, after 14 DIV, displayed substantial cellular protrusions from slice edges, including cells that expressed both glial and neuronal markers. In summary, we present a substantial evaluation of the viability and morphological changes that occur in the neocortex of whole brain tissue cultures, from different ages, over an extended period of culture.

  2. Migration of gases around a cell containing high-activity vitrified wastes during the operational phase

    International Nuclear Information System (INIS)

    Hoch, A.; Wendling, J.

    2010-01-01

    Document available in extended abstract form only. Andra is studying the Callovo-Oxfordian mud-stones, located at a depth of approximately 500 m beneath the borders of the Meuse and the Haute-Marne Departements, in order to assess the feasibility of constructing a repository for radioactive waste in this low-permeability geological formation. Several categories of waste are being considered for disposal in the geological repository. Of these, the high-activity, long-lived vitrified wastes (known as 'Waste C') are strongly exothermic and will be stored in cells that are about 40 m long, with a single access aperture from an access gallery. The cell wall will be supported by a steel lining. During the reversible operational phase (lasting at least 100 years), and as long as the access galleries are ventilated, the corrosion of the steel lining by oxygen in air will be important. It is necessary to determine the thickness of the lining corroded during this phase in order to be able to design the lining with an appropriate initial thickness to maintain integrity. In addition, at the end of the cell farthest from the ventilated access gallery, it is possible that the oxygen concentration will be so low that corrosion occurs under reducing (anaerobic) conditions. This chemical reaction produces hydrogen gas, which will migrate towards the access gallery. To maintain operational safety, it is necessary to define the hydrogen concentration within the cell and within the access gallery in order to evaluate the fire and/or explosion hazards (the hydrogen-oxygen mixture is highly flammable and/or explosive at certain concentrations). The objectives of this study were to estimate for the reversible operational phase (i.e. for 100 years): - The thickness of the steel lining required to ensure mechanical integrity. - Transfer rates (advection and / or diffusion) and gas concentrations (oxygen, hydrogen and water vapour) at all points in the annular void between the

  3. Ex vivo culture of patient tissue & examination of gene delivery.

    LENUS (Irish Health Repository)

    Rajendran, Simon

    2012-01-31

    This video describes the use of patient tissue as an ex vivo model for the study of gene delivery. Fresh patient tissue obtained at the time of surgery is sliced and maintained in culture. The ex vivo model system allows for the physical delivery of genes into intact patient tissue and gene expression is analysed by bioluminescence imaging using the IVIS detection system. The bioluminescent detection system demonstrates rapid and accurate quantification of gene expression within individual slices without the need for tissue sacrifice. This slice tissue culture system may be used in a variety of tissue types including normal and malignant tissue and allows us to study the effects of the heterogeneous nature of intact tissue and the high degree of variability between individual patients. This model system could be used in certain situations as an alternative to animal models and as a complementary preclinical mode prior to entering clinical trial.

  4. The hypothalamic slice approach to neuroendocrinology.

    Science.gov (United States)

    Hatton, G I

    1983-07-01

    The magnocellular peptidergic cells of the supraoptic and paraventricular nuclei comprise much of what is known as the hypothalamo-neurohypophysial system and is involved in several functions, including body fluid balance, parturition and lactation. While we have learned much from experiments in vivo, they have not produced a clear understanding of some of the crucial features associated with the functioning of this system. In particular, questions relating to the osmosensitivity of magnocellular neurones and the mechanism(s) by which their characteristic firing patterns are generated have not been answered using the older approaches. Electrophysiological studies with brain slices present direct evidence for osmosensitivity, and perhaps even osmoreceptivity, of magnocellular neurones. Other evidence indicates that the phasic bursting patterns of activity associated with vasopressin-releasing neurones (a) occur in the absence of patterned chemical synaptic input, (b) may be modulated by electrotonic conduction across gap junctions connecting magnocellular neurones and (c) are likely to be generated by endogenous membrane currents. These results make untenable the formerly held idea that phasic bursting activity is dependent upon recurrent synaptic inhibition.

  5. Slice-based supine to standing postured deformation for chinese anatomical models and the dosimetric results by wide band frequency electromagnetic field exposure: Morphing

    International Nuclear Information System (INIS)

    Wu, T.; Tan, L.; Shao, Q.; Li, Y.; Yang, L.; Zhao, C.; Xie, Y.; Zhang, S.

    2013-01-01

    Digital human models are frequently obtained from supine-postured medical images or cadaver slices, but many applications require standing models. This paper presents the work of reconstructing standing Chinese adult anatomical models from supine postured slices. Apart from the previous studies, the deformation works on 2-D segmented slices. The surface profile of the standing posture is adjusted by population measurement data. A non-uniform texture amplification approach is applied on the 2-D slices to recover the skin contour and to redistribute the internal tissues. Internal organ shift due to postures is taken into account. The feet are modified by matrix rotation. Then, the supine and standing models are utilised for the evaluation of electromagnetic field exposure over wide band frequency and different incident directions. . (authors)

  6. The effect of slicing type on drying kinetics and quality of dried carrot

    Directory of Open Access Journals (Sweden)

    M Naghipour zadeh mahani

    2016-04-01

    Full Text Available Introduction: Carrot is one of the most common vegetables used for human nutrition because of its high vitamin and fiber contents. Drying improves the product shelf life without addition of any chemical preservative and reduces both the size of package and the transport cost. Drying also aidsto reduce postharvest losses of fruits and vegetables especially, which can be as high as 70%. Dried carrots are used in dehydrated soups and in the form of powder in pastries and sauces. The main aim of drying agricultural products is decrease the moisture content to a level which allows safe storage over an extended period. Many fruits and vegetables can be sliced before drying.because of different tissue of a fruit or vegetable, cutting them in different direction and shape created different tissue slices. Due to drying is the exiting process of the moisture from internal tissue so different tissue slices caused different drying kinetics. Therefore, the study on effect of cutting parameters on drying is necessary. Materials and Methods: Carrots (Daucus carota L. were purchased from the local market (Kerman, Iran and stored in a refrigerator at 5°C. The initial moisture contents of the Carrot samples were determined by the oven drying method. The sample was dried in an oven at 105±2°C about 24 hours. The carrots cut by 3 models blade at 3 directions. The samples were dried in an oven at 70°C. Moisture content of the carrot slices were determined by weighting of samples during drying. Volume changes because of sample shrinkage were measured by a water displacement method. Rehydration experiment was performed by immersing a weighted amount of dried samples into hot water 50 °C for 30 min. In this study the effect of some cutting parameters was considered on carrot drying and the quality of final drying product. The tests were performed as a completely random design. The effects of carrot thickness at two levels (3 and 6 mm, blade in 3 models (flat blade

  7. Automated fetal brain segmentation from 2D MRI slices for motion correction.

    Science.gov (United States)

    Keraudren, K; Kuklisova-Murgasova, M; Kyriakopoulou, V; Malamateniou, C; Rutherford, M A; Kainz, B; Hajnal, J V; Rueckert, D

    2014-11-01

    Motion correction is a key element for imaging the fetal brain in-utero using Magnetic Resonance Imaging (MRI). Maternal breathing can introduce motion, but a larger effect is frequently due to fetal movement within the womb. Consequently, imaging is frequently performed slice-by-slice using single shot techniques, which are then combined into volumetric images using slice-to-volume reconstruction methods (SVR). For successful SVR, a key preprocessing step is to isolate fetal brain tissues from maternal anatomy before correcting for the motion of the fetal head. This has hitherto been a manual or semi-automatic procedure. We propose an automatic method to localize and segment the brain of the fetus when the image data is acquired as stacks of 2D slices with anatomy misaligned due to fetal motion. We combine this segmentation process with a robust motion correction method, enabling the segmentation to be refined as the reconstruction proceeds. The fetal brain localization process uses Maximally Stable Extremal Regions (MSER), which are classified using a Bag-of-Words model with Scale-Invariant Feature Transform (SIFT) features. The segmentation process is a patch-based propagation of the MSER regions selected during detection, combined with a Conditional Random Field (CRF). The gestational age (GA) is used to incorporate prior knowledge about the size and volume of the fetal brain into the detection and segmentation process. The method was tested in a ten-fold cross-validation experiment on 66 datasets of healthy fetuses whose GA ranged from 22 to 39 weeks. In 85% of the tested cases, our proposed method produced a motion corrected volume of a relevant quality for clinical diagnosis, thus removing the need for manually delineating the contours of the brain before motion correction. Our method automatically generated as a side-product a segmentation of the reconstructed fetal brain with a mean Dice score of 93%, which can be used for further processing. Copyright

  8. Modelling glioblastoma tumour-host cell interactions using adult brain organotypic slice co-culture

    Directory of Open Access Journals (Sweden)

    Maria Angeles Marques-Torrejon

    2018-02-01

    Full Text Available Glioblastoma multiforme (GBM is an aggressive incurable brain cancer. The cells that fuel the growth of tumours resemble neural stem cells found in the developing and adult mammalian forebrain. These are referred to as glioma stem cells (GSCs. Similar to neural stem cells, GSCs exhibit a variety of phenotypic states: dormant, quiescent, proliferative and differentiating. How environmental cues within the brain influence these distinct states is not well understood. Laboratory models of GBM can be generated using either genetically engineered mouse models, or via intracranial transplantation of cultured tumour initiating cells (mouse or human. Unfortunately, these approaches are expensive, time-consuming, low-throughput and ill-suited for monitoring live cell behaviours. Here, we explored whole adult brain coronal organotypic slices as an alternative model. Mouse adult brain slices remain viable in a serum-free basal medium for several weeks. GSCs can be easily microinjected into specific anatomical sites ex vivo, and we demonstrate distinct responses of engrafted GSCs to diverse microenvironments in the brain tissue. Within the subependymal zone – one of the adult neural stem cell niches – injected tumour cells could effectively engraft and respond to endothelial niche signals. Tumour-transplanted slices were treated with the antimitotic drug temozolomide as proof of principle of the utility in modelling responses to existing treatments. Engraftment of mouse or human GSCs onto whole brain coronal organotypic brain slices therefore provides a simplified, yet flexible, experimental model. This will help to increase the precision and throughput of modelling GSC-host brain interactions and complements ongoing in vivo studies. This article has an associated First Person interview with the first author of the paper.

  9. The Slice Algorithm For Irreducible Decomposition of Monomial Ideals

    DEFF Research Database (Denmark)

    Roune, Bjarke Hammersholt

    2009-01-01

    Irreducible decomposition of monomial ideals has an increasing number of applications from biology to pure math. This paper presents the Slice Algorithm for computing irreducible decompositions, Alexander duals and socles of monomial ideals. The paper includes experiments showing good performance...

  10. Study of Energy Consumption of Potato Slices During Drying Process

    Directory of Open Access Journals (Sweden)

    Hafezi Negar

    2015-06-01

    Full Text Available One of the new methods of food drying using infrared heating under vacuum is to increase the drying rate and maintain the quality of dried product. In this study, potato slices were dried using vacuum-infrared drying. Experiments were performed with the infrared lamp power levels 100, 150 and 200 W, absolute pressure levels 20, 80, 140 and 760 mmHg, and with three thicknesses of slices 1, 2 and 3 mm, in three repetitions. The results showed that the infrared lamp power, absolute pressure and slice thickness have important effects on the drying of potato. With increasing the radiation power, reducing the absolute pressure (acts of vacuum in the dryer chamber and also reducing the thickness of potato slices, drying time and the amount of energy consumed is reduced. In relation to thermal utilization efficiency, results indicated that with increasing the infrared radiation power and decreasing the absolute pressure, thermal efficiency increased.

  11. CASTOR registered HAW28M - a high heat load cask for transport and storage of vitrified high level waste containers

    International Nuclear Information System (INIS)

    Vossnacke, A.; Klein, K.; Kuehne, B.

    2004-01-01

    Within the German return programme for vitrified high level waste (HLW) from reprocessing at COGEMA and BNFL up to now 39 casks loaded with 28 containers each were transported back to Germany and are stored in the Interim Storage Facility Gorleben (TBL-G) for up to 40 years. For transport and storage in all but one case the GNB casks CASTOR registered HAW 20/28 CG have been used. This cask type is designed to accommodate 20 or 28 HLW containers with a total thermal power of 45 kW maximum. In the near future, among the high level waste, which has to be returned to Germany, there will be an increasing number of containers of which the heat capacity and radioactive inventory will exceed the technical limits of the CASTOR registered HAW 20/28 CG. Therefore GNB has started the development of a new cask generation, named CASTOR registered HAW28M, meeting these future requirements. The CASTOR registered HAW28M is especially developed for the transport of vitrified residues from France and Great Britain to Germany. It complies with the international regulations for type B packages according to IAEA (International Atomic Energy Agency). It is thus guaranteed that even in case of any accident the cask body and the lid system remain functional and the safe confinement of the radioactive contents remains intact during transport. The CASTOR registered HAW28M fulfills not only the requirements for transport but also the acceptance criteria of interim storage: radiation shielding, heat dissipation, safe confinement under both normal and hypothetical accident conditions. Storage buildings such as the TBL-G simply support the safety functions of the cask. The challenge for the development results from higher requirements of the technical specification, particularly related to fuel which is reprocessed. As a consequence of the reprocessing of fuel with increased enrichment and burn up, higher heat capacity and sophisticated shielding measures have to be considered. For the CASTOR

  12. Resource slicing in virtual wireless networks: a survey

    OpenAIRE

    Richart, Matias; Baliosian De Lazzari, Javier Ernesto; Serrat Fernández, Juan; Gorricho Moreno, Juan Luis

    2016-01-01

    New architectural and design approaches for radio access networks have appeared with the introduction of network virtualization in the wireless domain. One of these approaches splits the wireless network infrastructure into isolated virtual slices under their own management, requirements, and characteristics. Despite the advances in wireless virtualization, there are still many open issues regarding the resource allocation and isolation of wireless slices. Because of the dynamics and share...

  13. Loading, transport and storage of casks of the type CASTOR registered HAW28M in the frame of vitrified high-level waste repatriation from France

    International Nuclear Information System (INIS)

    Horn, Thomas; Graf, Wilhelm; Gosch-Warning, Michaela

    2011-01-01

    Until 2005 the German nuclear power plant operators have contracts with AREVA NC (former COGEMA) and NDA (former BNFL) concerning the reprocessing of spent fuel elements. The reprocessed and vitrified radioactive waste has to be repatriated to Germany. Due to the reprocessing of spent fuel elements with increased burnup and the repatriation after shorter cooling time the total activity and the Cm-244 content of the high-level-waste coquilles have increased since 2008. Consequently the heat output has increased to 2 kW/coquille. Therefore the new transport cask type CASTOR registered HAW28M was developed. The authors describe the design of the casks, the licensing according to the German transport regulations, loading procedures, radiation measurements and shipment completion. In autumn 2011 the repatriation of vitrified high-level waste from France is supposed to be completed with the transport of eleven CASTOR registered HAW28M.

  14. NMR surprizes with thin slices and strong gradients

    Energy Technology Data Exchange (ETDEWEB)

    Gaedke, Achim; Kresse, Benjamin [Institute of Condensed Matter Physics, Technische Universitaet Darmstadt (Germany); Nestle, Nikolaus

    2008-07-01

    In the context of our work on diffusion-relaxation-coupling in thin excited slices, we perform NMR experiments in static magnetic field gradients up to 200 T/m. For slice thicknesses in the range of 10{mu}m, the frequency bandwidth of the excited slices becomes sufficiently narrow that free induction decays (FIDs) become observable despite the presence of the strong static gradient. The observed FIDs were also simulated using standard methods from MRI physics. Possible effects of diffusion during the FID duration are still minor at this slice thickness in water but might become dominant for smaller slices or more diffusive media. Furthermore, the detailed excitation structure of the RF pulses was studied in profiling experiments over the edge of a plane liquid cell. Side lobe effects to the slices will be discussed along with approaches to control them. The spatial resolution achieved in the profiling experiments furthermore allows the identification of thermal expansion phenomena in the NMR magnet. Measures to reduce the temperature drift problems are presented.

  15. Generalized Fourier slice theorem for cone-beam image reconstruction.

    Science.gov (United States)

    Zhao, Shuang-Ren; Jiang, Dazong; Yang, Kevin; Yang, Kang

    2015-01-01

    The cone-beam reconstruction theory has been proposed by Kirillov in 1961, Tuy in 1983, Feldkamp in 1984, Smith in 1985, Pierre Grangeat in 1990. The Fourier slice theorem is proposed by Bracewell 1956, which leads to the Fourier image reconstruction method for parallel-beam geometry. The Fourier slice theorem is extended to fan-beam geometry by Zhao in 1993 and 1995. By combining the above mentioned cone-beam image reconstruction theory and the above mentioned Fourier slice theory of fan-beam geometry, the Fourier slice theorem in cone-beam geometry is proposed by Zhao 1995 in short conference publication. This article offers the details of the derivation and implementation of this Fourier slice theorem for cone-beam geometry. Especially the problem of the reconstruction from Fourier domain has been overcome, which is that the value of in the origin of Fourier space is 0/0. The 0/0 type of limit is proper handled. As examples, the implementation results for the single circle and two perpendicular circle source orbits are shown. In the cone-beam reconstruction if a interpolation process is considered, the number of the calculations for the generalized Fourier slice theorem algorithm is O(N^4), which is close to the filtered back-projection method, here N is the image size of 1-dimension. However the interpolation process can be avoid, in that case the number of the calculations is O(N5).

  16. Shielding calculations with SCALE/MAVRIC and comparison with measurements for the TN85 cask with vitrified high level radioactive waste

    Science.gov (United States)

    Thiele, Holger; Börst, Frank-Michael

    2017-09-01

    A series of dose rate/spectra measurements in the German interim storage facility Gorleben was carried out at a TN85 cask in April 2009. This type of cask is used for the transport and interim storage of vitrified high level radioactive waste (HAW) from reprocessing. The aim of this work is to assess the shielding component MAVRIC of the SCALE code system with these measurements for the use in the German Bundesamt für Kerntechnische Entsorgungssicherheit (BfE).

  17. Vitrified waste form performance modeling applied to the treatment and disposal of mixed-waste sludge at the Savannah River Site

    International Nuclear Information System (INIS)

    Whited, A.R.; Fjeld, R.A.

    1998-01-01

    Vitrification, the conversion of source components into a solid amorphous glass matrix, has emerged as a viable treatment technology for low-level radioactive waste and mixed waste. To dispose of vitrified low-level waste at US Department of Energy facilities, site-specific radiological performance assessments must be conducted to demonstrate that waste glass satisfies performance objectives for environmental protection. More than 2,500 m 3 of F0006-listed low-level mixed-waste sludge stored in the Reactor Materials Department (M-Area) at the Savannah River Site (SRS) is scheduled for vitrification. This study evaluates the feasibility of on-site disposal of vitrified M-Area waste at SRS. Laboratory leaching tests that accelerate the glass corrosion process are currently the best indicators of vitrified waste form durability. A method to incorporate laboratory leaching data into performance assessments is presented. A screening-level performance assessments code is used to model trench disposal of M-Area waste glass. The allowable leach rate for vitrified M-Area waste is determined based on both a maximum radiological dose equivalent of 4 mrem/yr for the drinking water pathway and a maximum uranium concentration of 20 microg/ell in groundwater. The allowable leach rate is compared with published long-term leaching data for a wide range of waste glass compositions and test conditions. This analysis demonstrates that trench disposal of the waste glass is likely to meet applicable performance objectives if the glass is of above average durability compared with the reference set of glasses

  18. Three dimensional culture of fresh and vitrified mouse pre-antral follicles in a hyaluronan-based hydrogel: a preliminary investigation of a novel biomaterial for in vitro follicle maturation

    Directory of Open Access Journals (Sweden)

    Desai Nina

    2012-06-01

    Full Text Available Abstract Background Folliculogenesis within the ovary requires interaction between somatic cell components and the oocyte. Maintenance of 3-dimensional (3-D architecture and granulosa-oocyte interaction may be critical for successful in vitro maturation of follicles. Testing of novel biomaterials for the 3-D culture of follicles may ultimately lead to a culture model that can support the longer in vitro culture intervals needed for in vitro maturation of human oocytes from ovarian tissue biopsies. Methods A novel tyramine-based hyaluronan (HA hydrogel was tested for its biocompatibility with ovarian follicles. The HA was prepared at concentrations from 2 to 5 mg/ml. HA hydrogel was also formulated and tested with matrix proteins (ECM. Enzymatically isolated pre-antral follicles from the ovaries of 10–12 day SJL pups were divided amongst control (CT and HA treatments. The growth of both fresh and vitrified follicles was assessed after encapsulation in the hydrogel. The basal culture medium was MEM alpha supplemented with FSH, LH, ITS and 5% FBS. Maturation was triggered by addition of hCG and EGF after in vitro culture (IVC. Outcome parameters monitored were follicle morphology, survival after IVC, antrum formation, GVBD and MII formation. Differences between treatments were analyzed. Results HA and ECM-HA encapsulated follicles looked healthy and maintained their 3-D architecture during IVC. In control cultures, the follicles flattened and granulosa:oocyte connections appeared fragile. Estradiol secretion per follicle was significantly higher by Day 12 in ECM-HA compared to HA or CT (4119, 703 and 1080 pg/ml, respectively. HA and ECM-HA cultured follicles had similar survival rates (62% and 54%, respectively, percent GV breakdown (96–97%, MII formation (47–48% and oocyte diameters at the end of IVC. Control cultures differed significantly in percent GVBD (85% and MII formation (67% . Vitrified-warmed follicles encapsulated in HA had

  19. Developmental Competence of Vitrified-Warmed Bovine Oocytes at the Germinal-Vesicle Stage is Improved by Cyclic Adenosine Monophosphate Modulators during In Vitro Maturation.

    Directory of Open Access Journals (Sweden)

    Kenji Ezoe

    Full Text Available Cryopreservation of mature oocytes and embryos has provided numerous benefits in reproductive medicine. Although successful cryopreservation of germinal-vesicle stage (GV oocytes holds promise for further advances in reproductive biology and clinical embryology fields, reports regarding cryopreservation of immature oocytes are limited. Oocyte survival and maturation rates have improved since vitrification is being performed at the GV stage, but the subsequent developmental competence of GV oocytes is still low. The purpose of this study was to evaluate the effects of supplementation of the maturation medium with cyclic adenosine monophosphate (cAMP modulators on the developmental competence of vitrified-warmed GV bovine oocytes. GV oocytes were vitrified-warmed and cultured to allow for oocyte maturation, and then parthenogenetically activated or fertilized in vitro. Our results indicate that addition of a cAMP modulator forskolin (FSK or 3-isobutyl-1-methylxanthine (IBMX to the maturation medium significantly improved the developmental competence of vitrified-warmed GV oocytes. We also demonstrated that vitrification of GV oocytes led to a decline in cAMP levels and maturation-promoting factor (MPF activity in the oocytes during the initial and final phases of maturation, respectively. Nevertheless, the addition of FSK or IBMX to the maturation medium significantly elevated cAMP levels and MPF activity during IVM. Taken together, our results suggest that the cryopreservation-associated meiotic and developmental abnormalities observed in GV oocytes may be ameliorated by an artificial increase in cAMP levels during maturation culture after warming.

  20. Cryostorage duration does not affect pregnancy and neonatal outcomes: a retrospective single-centre cohort study of vitrified-warmed blastocysts.

    Science.gov (United States)

    Ueno, Satoshi; Uchiyama, Kazuo; Kuroda, Tomoko; Yabuuchi, Akiko; Ezoe, Kenji; Okimura, Tadashi; Okuno, Takashi; Kobayashi, Tamotsu; Kato, Keiichi

    2018-06-01

    A retrospective cohort study of 8736 autologous single vitrified-warmed blastocyst transfer cycles was conducted in a single centre to investigate the effect of cryostorage on clinical and neonatal outcomes. Cryostorage duration was classified into three groups: (A) 0-2 months (n = 4702); (B) 2-13 months (n = 2853) and (C) 13-97 months (n = 1181). Blastocysts were vitrified using the Cryotop method. No significant differences were observed in live birth rates: (A) 37.3%; (B) 34.9%; (C) (35.2%). Gestational period was significantly shorter in group C: (A) 38.7 ± 1.8; (B) 38.6 ± 1.6; (C) 38.1 ± 1.7; P limitation of this study was that maximum storage duration was 8 years; most blastocysts were in cryostorage for much shorter periods. Long-term storage of blastocysts that are vitrified using an open device vitrification system has no negative effect on pregnancy and neonatal outcomes. Copyright © 2018 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  1. Test of 134Cs, 85,89Sr leaching rate in a resemble vitrifiable cement waste form

    International Nuclear Information System (INIS)

    Lin Meiqiong; Wei Feng; Yin Qi; Fan Xianhua; Xu Shengli; Li Yongde

    2003-01-01

    A novel material--resemble vitrifiable cement for conditioning low and mediate level radioactive waste has been developed. Waste form has been characterized for their physical and chemical performance, phase composition. The cement formulation has been patented. In this experiment the cement is mixed with simulated wastes spiked with 134 Cs and 85,89 Sr by 5 min at least. The Ratio of the waste to the cement is 0.45-0.55. The mixture is packed into cylindrical molds which has the same dimension of diameter and height . The grouts are cured for a period of 28 d in a room temperature curing chamber at an atmospheric pressure. The cured waste form is then completely immersed into deionized water. According to standard GB7023-86, leaching rate of 134 Cs and 85,89 Sr are measured. The result shows that the leaching rate of the species 134 Cs and 85,89 Sr is to be on the order 10 -4 and 10 -5 on the 42 d immersion, respectively and is better than that of commercial cement

  2. FY-97 operations of the pilot-scale glass melter to vitrify simulated ICPP high activity sodium-bearing waste

    International Nuclear Information System (INIS)

    Musick, C.A.

    1997-11-01

    A 3.5 liter refractory-lined joule-heated glass melter was built to test the applicability of electric melting to vitrify simulated high activity waste (HAW). The HAW streams result from dissolution and separation of Idaho Chemical Processing Plant (ICPP) calcines and/or radioactive liquid waste. Pilot scale melter operations will establish selection criteria needed to evaluate the application of joule heating to immobilize ICPP high activity waste streams. The melter was fabricated with K-3 refractory walls and Inconel 690 electrodes. It is designed to be continuously operated at 1,150 C with a maximum glass output rate of 10 lbs/hr. The first set of tests were completed using surrogate HAW-sodium bearing waste (SBW). The melter operated for 57 hours and was shut down due to excessive melt temperatures resulting in low glass viscosity (< 30 Poise). Due to the high melt temperature and low viscosity the molten glass breached the melt chamber. The melter has been dismantled and examined to identify required process improvement areas and successes of the first melter run. The melter has been redesigned and is currently being fabricated for the second run, which is scheduled to begin in December 1997

  3. Integrated fMRI Preprocessing Framework Using Extended Kalman Filter for Estimation of Slice-Wise Motion

    OpenAIRE

    Basile Pinsard; Basile Pinsard; Basile Pinsard; Arnaud Boutin; Arnaud Boutin; Julien Doyon; Julien Doyon; Habib Benali; Habib Benali; Habib Benali

    2018-01-01

    Functional MRI acquisition is sensitive to subjects' motion that cannot be fully constrained. Therefore, signal corrections have to be applied a posteriori in order to mitigate the complex interactions between changing tissue localization and magnetic fields, gradients and readouts. To circumvent current preprocessing strategies limitations, we developed an integrated method that correct motion and spatial low-frequency intensity fluctuations at the level of each slice in order to better fit ...

  4. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  5. Methods to induce primary and secondary traumatic damage in organotypic hippocampal slice cultures.

    Science.gov (United States)

    Adamchik, Y; Frantseva, M V; Weisspapir, M; Carlen, P L; Perez Velazquez, J L

    2000-04-01

    Organotypic brain slice cultures have been used in a variety of studies on neurodegenerative processes [K.M. Abdel-Hamid, M. Tymianski, Mechanisms and effects of intracellular calcium buffering on neuronal survival in organotypic hippocampal cultures exposed to anoxia/aglycemia or to excitotoxins, J. Neurosci. 17, 1997, pp. 3538-3553; D.W. Newell, A. Barth, V. Papermaster, A.T. Malouf, Glutamate and non-glutamate receptor mediated toxicity caused by oxygen and glucose deprivation in organotypic hippocampal cultures, J. Neurosci. 15, 1995, pp. 7702-7711; J.L. Perez Velazquez, M.V. Frantseva, P.L. Carlen, In vitro ischemia promotes glutamate mediated free radical generation and intracellular calcium accumulation in pyramidal neurons of cultured hippocampal slices, J. Neurosci. 23, 1997, pp. 9085-9094; L. Stoppini, L.A. Buchs, D. Muller, A simple method for organotypic cultures of nervous tissue, J. Neurosci. Methods 37, 1991, pp. 173-182; R.C. Tasker, J.T. Coyle, J.J. Vornov, The regional vulnerability to hypoglycemia induced neurotoxicity in organotypic hippocampal culture: protection by early tetrodotoxin or delayed MK 801, J. Neurosci. 12, 1992, pp. 4298-4308.]. We describe two methods to induce traumatic cell damage in hippocampal organotypic cultures. Primary trauma injury was achieved by rolling a stainless steel cylinder (0.9 g) on the organotypic slices. Secondary injury was followed after dropping a weight (0.137 g) on a localised area of the organotypic slice, from a height of 2 mm. The time course and extent of cell death were determined by measuring the fluorescence of the viability indicator propidium iodide (PI) at several time points after the injury. The initial localised impact damage spread 24 and 67 h after injury, cell death being 25% and 54%, respectively, when slices were kept at 37 degrees C. To validate these methods as models to assess neuroprotective strategies, similar insults were applied to slices at relatively low temperatures (30

  6. Effect of halide salts on development of surface browning on fresh-cut 'Granny Smith' (Malus × domestica Borkh) apple slices during storage at low temperature.

    Science.gov (United States)

    Li, Yongxin; Wills, Ron B H; Golding, John B; Huque, Roksana

    2015-03-30

    The postharvest life of fresh-cut apple slices is limited by browning on cut surfaces. Dipping in halide salt solutions was examined for their inhibition of surface browning on 'Granny Smith' apple slices and the effects on biochemical factors associated with browning. Delay in browning by salts was greatest with chloride = phosphate > sulfate > nitrate with no difference between sodium, potassium and calcium ions. The effectiveness of sodium halides on browning was fluoride > chloride = bromide > iodide = control. Polyphenol oxidase (PPO) activity of tissue extracted from chloride- and fluoride-treated slices was not different to control but when added into the assay solution, NaF > NaCl both showed lower PPO activity at pH 3-5 compared to control buffer. The level of polyphenols in treated slices was NaF > NaCl > control. Addition of chlorogenic acid to slices enhanced browning but NaCl and NaF counteracted this effect. There was no effect of either halide salt on respiration, ethylene production, ion leakage, and antioxidant activity. Dipping apple slices in NaCl is a low cost treatment with few impediments to commercial use and could be a replacement for other anti-browning additives. The mode of action of NaCl and NaF is through decreasing PPO activity resulting in reduced oxidation of polyphenols. © 2014 Society of Chemical Industry.

  7. Evaluation of the relative biological effectiveness of carbon ion beams in the cerebellum using the rat organotypic slice culture system

    International Nuclear Information System (INIS)

    Yoshida, Yukari; Katoh, Hiroyuki; Nakano, Takashi; Suzuki, Yoshiyuki; Al-Jahdari, Wael S.; Shirai, Katsuyuki; Hamada, Nobuyuki; Funayama, Tomoo; Sakashita, Tetsuya; Kobayashi, Yasuhiko

    2012-01-01

    The purpose of this study was to clarify the relative biological effectiveness (RBE) values of carbon ion (C) beams in normal brain tissues, a rat organotypic slice culture system was used. The cerebellum was dissected from 10-day-old Wistar rats, cut parasagittally into approximately 600-μm-thick slices and cultivated using a membrane-based culture system with a liquid-air interface. Slices were irradiated with 140 kV X-rays and 18.3 MeV/amu C-beams (linear energy transfer=108 keV/μm). After irradiation, the slices were evaluated histopathologically using hematoxylin and eosin staining, and apoptosis was quantified using the TdT-mediated dUTP-biotin nick-end labeling (TUNEL) assay. Disorganization of the external granule cell layer (EGL) and apoptosis of the external granule cells (EGCs) were induced within 24 h after exposure to doses of more than 5 Gy from C-beams and X-rays. In the early postnatal cerebellum, morphological changes following exposure to C-beams were similar to those following exposure to X-rays. The RBEs values of C-beams using the EGL disorganization and the EGC TUNEL index endpoints ranged from 1.4 to 1.5. This system represents a useful model for assaying the biological effects of radiation on the brain, especially physiological and time-dependent phenomena. (author)

  8. Myocardial slice: a physiological approach to beta-adrenergic ([3H] CGP-12177) receptor binding in hamster and guinea pig heart.

    Science.gov (United States)

    Watson-Wright, W M; Armour, J A; Johnstone, D E; Wilkinson, M

    1989-08-01

    A new technique is described for the characterization and quantification of beta-adrenergic receptors in biologically viable slices of myocardium from the hamster right ventricle using the hydrophilic radioligand, [3H]CGP-12177 (CGP). Binding was stereospecific, saturable, of high affinity, reversible, displaceable by appropriate drugs, and highly positively correlated with increasing tissue concentrations. Bmax for CGP binding to myocardial slices from 50-day-old male Golden Syrian hamsters was 3.28 +/- 0.15 fmol/mg wet weight, while Kd was 0.21 +/- 0.02 nM. Freezing resulted in a close to 50% loss of receptor number with no apparent change in affinity. The slice preparation may be utilized to detect in vivo changes in myocardial cell surface receptors, as evidenced by the fact that the number of receptors in slices from ischemic guinea pigs was increased (Bmax = 15.5 +/- 1.25 fmol/mg wet wt) compared with sham-operated controls (Bmax = 10.4 +/- 0.38 fmol/mg wet wt). The minimal tissue disruption associated with this procedure, as well as its speed, simplicity, and relatively low cost, suggest that the myocardial slice preparation provides an important methodology for the study of beta-adrenergic receptor binding in the semiintact myocardium.

  9. Improved biochemical preservation of heart slices during cold storage.

    Science.gov (United States)

    Bull, D A; Reid, B B; Connors, R C; Albanil, A; Stringham, J C; Karwande, S V

    2000-01-01

    Development of myocardial preservation solutions requires the use of whole organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that myocardial slices could be used to assess preservation of biochemical function during cold storage. Whole rat hearts were precision cut into slices with a thickness of 200 microm and preserved at 4 degrees C in one of the following solutions: Columbia University (CU), University of Wisconsin (UW), D5 0.2% normal saline with 20 meq/l KCL (QNS), normal saline (NS), or a novel cardiac preservation solution (NPS) developed using this model. Myocardial biochemical function was assessed by ATP content (etamoles ATP/mg wet weight) and capacity for protein synthesis (counts per minute (cpm)/mg protein) immediately following slicing (0 hours), and at 6, 12, 18, and 24 hours of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as the mean +/- standard deviation. ATP content was higher in the heart slices stored in the NPS compared to all other solutions at 6, 12, 18 and 24 hours of cold storage (p cold storage (p cold storage.

  10. Improved biochemical preservation of lung slices during cold storage.

    Science.gov (United States)

    Bull, D A; Connors, R C; Reid, B B; Albanil, A; Stringham, J C; Karwande, S V

    2000-05-15

    Development of lung preservation solutions typically requires whole-organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that lung slices could be used to assess preservation of biochemical function during cold storage. Whole rat lungs were precision cut into slices with a thickness of 500 microm and preserved at 4 degrees C in the following solutions: University of Wisconsin (UW), Euro-Collins (EC), low-potassium-dextran (LPD), Kyoto (K), normal saline (NS), or a novel lung preservation solution (NPS) developed using this model. Lung biochemical function was assessed by ATP content (etamol ATP/mg wet wt) and capacity for protein synthesis (cpm/mg protein) immediately following slicing (0 h) and at 6, 12, 18, and 24 h of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as means +/- SD. ATP content was significantly higher in the lung slices stored in NPS compared with all other solutions at each time point (P cold storage. Copyright 2000 Academic Press.

  11. [Standardization of production of process Notopterygii Rhizoma et Radix slices].

    Science.gov (United States)

    Sun, Zhen-Yang; Wang, Ying-Zi; Nie, Rui-Jie; Zhang, Jing-Zhen; Wang, Si-Yu

    2017-12-01

    Notopterol, isoimperatorin, volatile oil and extract (water and ethanol) were used as the research objects in this study to investigate the effects of different softening method, slice thickness and drying methods on the quality of Notopterygii Rhizoma et Radix slices, and the experimental data were analyzed by homogeneous distance evaluation method. The results showed that different softening, cutting and drying processes could affect the content of five components in Notopterygii Rhizoma et Radix incisum. The best processing technology of Notopterygii Rhizoma et Radix slices was as follows: non-medicinal parts were removed; mildewed and rot as well as moth-eaten parts were removed; washed by the flowing drinking water; stacked in the drug pool; moistening method was used for softening, where 1/8 volume of water was sprayed for every 1 kg of herbs every 2 h; upper part of herbs covered with clean and moist cotton, and cut into thick slices (2-4 mm) after 12 h moistening until appropriate softness, then received blast drying for 4 h at 50 ℃, and turned over for 2 times during the drying. The process is practical and provides the experimental basis for the standardization of the processing of Notopterygii Rhizoma et Radix, with great significance to improve the quality of Notopterygii Rhizoma et Radix slices. Copyright© by the Chinese Pharmaceutical Association.

  12. [Anatomy of the skull base and the cranial nerves in slice imaging].

    Science.gov (United States)

    Bink, A; Berkefeld, J; Zanella, F

    2009-07-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) are suitable methods for examination of the skull base. Whereas CT is used to evaluate mainly bone destruction e.g. for planning surgical therapy, MRI is used to show pathologies in the soft tissue and bone invasion. High resolution and thin slice thickness are indispensible for both modalities of skull base imaging. Detailed anatomical knowledge is necessary even for correct planning of the examination procedures. This knowledge is a requirement to be able to recognize and interpret pathologies. MRI is the method of choice for examining the cranial nerves. The total path of a cranial nerve can be visualized by choosing different sequences taking into account the tissue surrounding this cranial nerve. This article summarizes examination methods of the skull base in CT and MRI, gives a detailed description of the anatomy and illustrates it with image examples.

  13. Anatomy of the skull base and the cranial nerves in slice imaging

    International Nuclear Information System (INIS)

    Bink, A.; Berkefeld, J.; Zanella, F.

    2009-01-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) are suitable methods for examination of the skull base. Whereas CT is used to evaluate mainly bone destruction e.g. for planning surgical therapy, MRI is used to show pathologies in the soft tissue and bone invasion. High resolution and thin slice thickness are indispensible for both modalities of skull base imaging. Detailed anatomical knowledge is necessary even for correct planning of the examination procedures. This knowledge is a requirement to be able to recognize and interpret pathologies. MRI is the method of choice for examining the cranial nerves. The total path of a cranial nerve can be visualized by choosing different sequences taking into account the tissue surrounding this cranial nerve. This article summarizes examination methods of the skull base in CT and MRI, gives a detailed description of the anatomy and illustrates it with image examples. (orig.) [de

  14. Development and demonstration of prototype transportation equipment for emplacing HL vitrified waste canisters into small diameter bored horizontal disposal cells

    International Nuclear Information System (INIS)

    Seidler, Wolf K.; Bosgiraud, Jean-Michel; Londe, Louis

    2008-01-01

    Over a period of 4 and years the National Radioactive Waste Management Agency (Andra), working with a variety of Contractors mostly specializing in nuclear orientated mechanical applications, successfully designed, fabricated and demonstrated 2 very different prototype high level waste transport systems. The first system, based on air cushion technology, was developed primarily for very heavy loads (17 to 45 tonnes). The results of this work are described in a separate presentation (Paper 21) at this Conference. The second system, developed by Andra within the framework of the ESDRED Project, generally referred to as the 'Pushing Robot System' for vitrified waste canisters, is the subject of this paper. The 'Pushing Robot System' is a part of the French national disposal concept that is described in Andra's 'Dossier 2005'. The latter is a public document that can be viewed on Andra's web site (www.andra.fr). The 'Pushing Robot System' system is designed for the deep geological disposal (in clay formations) of 'C' type vitrified waste canisters. In its entirety the system provides for the transport, emplacement and, if necessary, the retrieval of those canisters. Nothing in the design of the Andra emplacement equipment would preclude its utilization in horizontal openings in other types of geological settings. Over a period of some 8 years Andra has developed the 'Pushing Robot System' in 3 phases. Initially there was only the 'Conceptual Design' (Phase 1) which was incorporated in the Dossier 2005. This was followed by Phase 2 i.e. the design and fabrication of a simplified full scale prototype system henceforth referred to a P1, which includes a Pushing Robot, a Dummy Canister and a Test Bench. P1 details were also incorporated in the Dossier 2005. Finally, during Phase 3, a second more comprehensive full scale prototype system P2 has been designed and is being assembled and tested this month. This system includes a Transport Shuttle, a Transfer Shielding Cask, a

  15. Color changes and acrylamide formation in fried potato slices

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Moyano, Pedro; Kaack, Karl

    2005-01-01

    The objective of this work was to study the kinetics of browning during deep-fat frying of blanched and unblanched potato chips by using the dynamic method and to find a relationship between browning development and acrylamide formation. Prior to frying, potato slices were blanched in hot water...... at 85degreesC for 3.5 min. Unblanched slices were used as the control. Control and blanched potato slices (Panda variety, diameter: 37 mm, width: 2.2 mm) were fried at 120, 150 and 180degreesC until reaching moisture contents of similar to1.8% (total basis) and their acrylamide content and final color...... were measured. Color changes were recorded at different sampling times during frying at the three mentioned temperatures using the chromatic redness parameter a(*). Experimental data of surface temperature, moisture content and color change in potato chips during frying were fit to empirical...

  16. An overview of 5G network slicing architecture

    Science.gov (United States)

    Chen, Qiang; Wang, Xiaolei; Lv, Yingying

    2018-05-01

    With the development of mobile communication technology, the traditional single network model has been unable to meet the needs of users, and the demand for differentiated services is increasing. In order to solve this problem, the fifth generation of mobile communication technology came into being, and as one of the key technologies of 5G, network slice is the core technology of network virtualization and software defined network, enabling network slices to flexibly provide one or more network services according to users' needs[1]. Each slice can independently tailor the network functions according to the requirements of the business scene and the traffic model and manage the layout of the corresponding network resources, to improve the flexibility of network services and the utilization of resources, and enhance the robustness and reliability of the whole network [2].

  17. Preservation of low slice emittance in bunch compressors

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-03-01

    Full Text Available Minimizing the dilution of the electron beam emittance is crucial for the performance of accelerators, in particular for free electron laser facilities, where the length of the machine and the efficiency of the lasing process depend on it. Measurements performed at the SwissFEL Injector Test Facility revealed an increase in slice emittance after compressing the bunch even for moderate compression factors. The phenomenon was experimentally studied by characterizing the dependence of the effect on beam and machine parameters relevant for the bunch compression. The reproduction of these measurements in simulation required the use of a 3D beam dynamics model along the bunch compressor that includes coherent synchrotron radiation. Our investigations identified transverse effects, such as coherent synchrotron radiation and transverse space charge as the sources of the observed emittance dilution, excluding other effects, such as chromatic effects on single slices or spurious dispersion. We also present studies, both experimental and simulation based, on the effect of the optics mismatch of the slices on the variation of the slice emittance along the bunch. After a corresponding reoptimization of the beam optics in the test facility we reached slice emittances below 200 nm for the central slices along the longitudinal dimension with a moderate increase up to 300 nm in the head and tail for a compression factor of 7.5 and a bunch charge of 200 pC, equivalent to a final current of 150 A, at about 230 MeV energy.

  18. Iron Phosphate Glass for Vitrifying Hanford AZ102 LAW in Joule Heated and Cold Crucible Induction Melters - 12240

    Energy Technology Data Exchange (ETDEWEB)

    Day, Delbert E.; Brow, Richard K.; Ray, Chandra S.; Reis, Signo T. [Missouri University of Science and Technology, 1870 Miner Circle, Rolla, MO 65409 (United States); Kim, Cheol-Woon [MO-SCI Corporation, 4040 HyPoint North, Rolla, MO 65401 (United States); Vienna, John D.; Sevigny, Gary [Pacific North West National Laboratory, Battelle Blvd., Richland, WA 99352 (United States); Peeler, David; Johnson, Fabienne C.; Hansen, Eric K. [Savannah River National Laboratory, Savannah River Site, 999-W, Aiken, SC 29803 (United States); Soelberg, Nick [Idaho National Laboratory, 2525 Fremont Avenue, Idaho Falls, ID 83415 (United States); Pegg, Ian L.; Gan, Hao [Catholic University of America, 620 Michigan Avenue, N.E., Washington, DC 20064 (United States)

    2012-07-01

    An iron phosphate composition for vitrifying a high sulfate (∼17 wt%) and high alkali (∼80 wt%) Hanford low activity waste (LAW), known as AZ-102 LAW, has been developed for processing in a Joule Heated Melter (JHM) or a Cold Crucible Induction Melter (CCIM). This composition produced a glass waste form, designated as MS26AZ102F-2, with a waste loading of 26 wt% of the AZ-102 which corresponded to a total alkali and sulfate (represented as SO{sub 3}) content of 21 and 4.4 wt%, respectively. A slurry (7 M Na{sup +}) of MS26AZ102F-2 simulant was melted continuously at temperatures between 1030 and 1090 deg. C for 10 days in a small JHM at PNNL and for 70 hours in a CCIM at INL. The as-cast glasses produced in both melters and in trial laboratory experiments along with their canister centerline cooled (CCC) counterparts met the requirements for the Product Consistency Test (PCT) and the Vapor Hydration Test (VHT) responses in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract. These glass waste forms retained up to 77 % of the SO{sub 3} (3.3 wt%), 100% of the Cesium, and 33 to 44% of the rhenium (used as a surrogate for Tc) all of which either exceeded or were comparable to the retention limit for these species in borosilicate glass nuclear waste form. Analyses of commercial K-3 refractory lining and the Inconel 693 metal electrodes used in JHM indicated only minimum corrosion of these components by the iron phosphate glass. This is the first time that an iron phosphate composition was melted continuously in a slurry fed JHM and in the US, thereby, demonstrating that iron phosphate glasses can be used as alternative hosts for vitrifying nuclear waste. The following conclusions are drawn from the results of the present work. (1) An iron phosphate composition, designated as MS26AZ102F-2, containing 26 wt% of the simulated high sulfate (17 wt%), high alkali (80 wt%) Hanford AZ-102 LAW meets all the criteria for processing in a JHM and CCIM. This

  19. (Non)perturbative gravity, nonlocality, and nice slices

    International Nuclear Information System (INIS)

    Giddings, Steven B.

    2006-01-01

    Perturbative dynamics of gravity is investigated for high-energy scattering and in black hole backgrounds. In the latter case, a straightforward perturbative analysis fails, in a close parallel to the failure of the former when the impact parameter reaches the Schwarzschild radius. This suggests a flaw in a semiclassical description of physics on spatial slices that intersect both outgoing Hawking radiation and matter that has carried information into a black hole; such slices are instrumental in a general argument for black hole information loss. This indicates a possible role for the proposal that nonperturbative gravitational physics is intrinsically nonlocal

  20. Verification-Driven Slicing of UML/OCL Models

    DEFF Research Database (Denmark)

    Shaikh, Asadullah; Clarisó Viladrosa, Robert; Wiil, Uffe Kock

    2010-01-01

    computational complexity can limit their scalability. In this paper, we consider a specific static model (UML class diagrams annotated with unrestricted OCL constraints) and a specific property to verify (satisfiability, i.e., “is it possible to create objects without violating any constraint?”). Current...... approaches to this problem have an exponential worst-case runtime. We propose a technique to improve their scalability by partitioning the original model into submodels (slices) which can be verified independently and where irrelevant information has been abstracted. The definition of the slicing procedure...

  1. Novel culturing platform for brain slices and neuronal cells

    DEFF Research Database (Denmark)

    Svendsen, Winnie Edith; Al Atraktchi, Fatima Al-Zahraa; Bakmand, Tanya

    2015-01-01

    In this paper we demonstrate a novel culturing system for brain slices and neuronal cells, which can control the concentration of nutrients and the waste removal from the culture by adjusting the fluid flow within the device. The entire system can be placed in an incubator. The system has been...... tested successfully with brain slices and PC12 cells. The culture substrate can be modified using metal electrodes and/or nanostructures for conducting electrical measurements while culturing and for better mimicking the in vivo conditions....

  2. Slice-based supine-to-standing posture deformation for chinese anatomical models and the dosimetric results with wide band frequency electromagnetic field exposure: Simulation

    International Nuclear Information System (INIS)

    Wu, T.; Tan, L.; Shao, Q.; Li, Y.; Yang, L.; Zhao, C.; Xie, Y.; Zhang, S.

    2013-01-01

    Standing Chinese adult anatomical models are obtained from supine-postured cadaver slices. This paper presents the dosimetric differences between the supine and the standing postures over wide band frequencies and various incident configurations. Both the body level and the tissue/organ level differences are reported for plane wave and the 3T magnetic resonance imaging radiofrequency electromagnetic field exposure. The influence of posture on the whole body specific absorption rate and tissue specified specific absorption rate values is discussed. . (authors)

  3. Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography

    International Nuclear Information System (INIS)

    Hsieh Jiang

    2001-01-01

    Multislice computed tomography (MCT) is one of the recent technology advancements in CT. Compared to single slice CT, MCT significantly improves examination time, x-ray tube efficiency, and contrast material utilization. Although the scan mode of MCT is predominately helical, step-and-shoot (axial) scans continue to be an important part of routine clinical protocols. In this paper, we present a detailed investigation on the slice sensitivity profile (SSP) of MCT in the step-and-shoot mode. Our investigation shows that, unlike single slice CT, the SSP for MCT exhibits multiple peaks and valleys resulting from intercell gaps between detector rows. To fully understand the characteristics of the SSP, we developed an analytical model to predict the behavior of MCT. We propose a simple experimental technique that can quickly and accurately measure SSP. The impact of the SSP on image artifacts and low contrast detectability is also investigated

  4. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  5. 3-Nitropropionic acid neurotoxicity in organotypic striatal and corticostriatal slice cultures is dependent on glucose and glutamate

    DEFF Research Database (Denmark)

    Storgaard, J; Kornblit, B T; Zimmer, J

    2000-01-01

    of lactate dehydrogenase in the medium and glutamic acid decarboxylase in tissue homogenates. 3-NPA toxicity (25-100 microM in 5 mM glucose, 24-48 h) appeared to be highly dependent on culture medium glucose levels. 3-NPA treatment caused also a dose-dependent lactate increase, reaching a maximum......Mitochondrial inhibition by 3-nitropropionic acid (3-NPA) causes striatal degeneration reminiscent of Huntington's disease. We studied 3-NPA neurotoxicity and possible indirect excitotoxicity in organotypic striatal and corticostriatal slice cultures. Neurotoxicity was quantified by assay...... of threefold increase above control at 100 microM. Both a high dose of glutamate (5 mM) and glutamate uptake blockade by dl-threo-beta-hydroxyaspartate potentiated 3-NPA neurotoxicity in corticostriatal slice cultures. Furthermore, striatum from corticostriatal cocultures was more sensitive to 3-NPA than...

  6. Implantation of glioblastoma spheroids into organotypic brain slice cultures as a model for investigating effects of irradiation

    DEFF Research Database (Denmark)

    Petterson, Stine Asferg; Jakobsen, Ida Pind; Jensen, Stine Skov

    2016-01-01

    , models for studying the effects of radiotherapy in combination with novel strategies are lacking but important since radiotherapy is the most successful non-surgical treatment of brain tumors. The aim of this study was to establish a glioblastoma spheroid-organotypic rat brain slice culture model...... comprising both tumors, tumor-brain interface and brain tissue to provide a proof of concept that this model is useful for studying effects of radiotherapy. Organotypic brain slice cultures cultured for 1-2 days or 11-16 days corresponding to immature brain and mature brain respectively were irradiated...... with doses between 10 and 50 Gy. There was a high uptake of the cell death marker propidium iodide in the immature cultures. In addition, MAP2 expression decreased whereas GFAP expression increased in these cultures suggesting neuronal death and astrogliosis. We therefore proceeded with the mature cultures...

  7. A slice through a prototype LHC bending magnet

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This slice through a prototype LHC magnet clearly shows the superconducting cable in several blocks around the central hole – the beam pipe in which the LHC’s accelerated beams will travel. Magnet design is crucial to the LHC’s success and this sample is among the first to be built to the final cable configuration.

  8. Continuous Slice Functional Calculus in Quaternionic Hilbert Spaces

    Science.gov (United States)

    Ghiloni, Riccardo; Moretti, Valter; Perotti, Alessandro

    2013-04-01

    The aim of this work is to define a continuous functional calculus in quaternionic Hilbert spaces, starting from basic issues regarding the notion of spherical spectrum of a normal operator. As properties of the spherical spectrum suggest, the class of continuous functions to consider in this setting is the one of slice quaternionic functions. Slice functions generalize the concept of slice regular function, which comprises power series with quaternionic coefficients on one side and that can be seen as an effective generalization to quaternions of holomorphic functions of one complex variable. The notion of slice function allows to introduce suitable classes of real, complex and quaternionic C*-algebras and to define, on each of these C*-algebras, a functional calculus for quaternionic normal operators. In particular, we establish several versions of the spectral map theorem. Some of the results are proved also for unbounded operators. However, the mentioned continuous functional calculi are defined only for bounded normal operators. Some comments on the physical significance of our work are included.

  9. Blanching, salting and sun drying of different pumpkin fruit slices.

    Science.gov (United States)

    Workneh, T S; Zinash, A; Woldetsadik, K

    2014-11-01

    The study was aimed at assessing the quality of pumpkin (Cucuribita Spp.) slices that were subjected to pre-drying treatments and drying using two drying methods (uncontrolled sun and oven) fruit accessions. Pre-drying had significant (P ≤ 0.05) effect on the quality of dried pumpkin slices. 10 % salt solution dipped pumpkin fruit slices had good chemical quality. The two-way interaction between drying methods and pre-drying treatments had significant (P ≤ 0.05) effect on chemical qualities. Pumpkin subjected to salt solution dipping treatment and oven dried had higher chemical concentrations. Among the pumpkin fruit accessions, pumpkin accession 8007 had the superior TSS, total sugar and sugar to acid ratio after drying. Among the three pre-drying treatment, salt solution dipping treatment had significant (P ≤ 0.05) effect and the most efficient pre-drying treatment to retain the quality of dried pumpkin fruits without significant chemical quality deterioration. Salt dipping treatment combined with low temperature (60 °C) oven air circulation drying is recommended to maintain quality of dried pumpkin slices. However, since direct sun drying needs extended drying time due to fluctuation in temperature, it is recommended to develop or select best successful solar dryer for use in combination with pre-drying salt dipping or blanching treatments.

  10. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    htmlabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  11. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    textabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  12. Bacteriological Quality of Dried Sliced Beef (Kilishi) Sold In Ilorin ...

    African Journals Online (AJOL)

    DR. MIKE HORSFALL

    ABSTRACT: The bacteriological quality of dried sliced beef (kilishi) obtained from three selling points in. Ilorin metropolis was determined in order to ascertain its safety. The total bacterial count, Enterobacteriaceae count, Staphylococcus aureus count and E.coli counts were used as index of bacteriological quality. Samples.

  13. Thin slice impressions : How advertising evaluation depends on exposure duration

    NARCIS (Netherlands)

    Pieters, Rik; Elsen, M.; Wedel, M.

    The duration of exposures to advertising is often brief. Then, consumers can only obtain “thin slices” of information from the ads, such as which product and brand are being promoted. This research is the first to examine the influence that such thin slices of information have on ad and brand

  14. Automatic Solitary Lung Nodule Detection in Computed Tomography Images Slices

    Science.gov (United States)

    Sentana, I. W. B.; Jawas, N.; Asri, S. A.

    2018-01-01

    Lung nodule is an early indicator of some lung diseases, including lung cancer. In Computed Tomography (CT) based image, nodule is known as a shape that appears brighter than lung surrounding. This research aim to develop an application that automatically detect lung nodule in CT images. There are some steps in algorithm such as image acquisition and conversion, image binarization, lung segmentation, blob detection, and classification. Data acquisition is a step to taking image slice by slice from the original *.dicom format and then each image slices is converted into *.tif image format. Binarization that tailoring Otsu algorithm, than separated the background and foreground part of each image slices. After removing the background part, the next step is to segment part of the lung only so the nodule can localized easier. Once again Otsu algorithm is use to detect nodule blob in localized lung area. The final step is tailoring Support Vector Machine (SVM) to classify the nodule. The application has succeed detecting near round nodule with a certain threshold of size. Those detecting result shows drawback in part of thresholding size and shape of nodule that need to enhance in the next part of the research. The algorithm also cannot detect nodule that attached to wall and Lung Chanel, since it depend the searching only on colour differences.

  15. The Sliced Pineapple Grid Feature for Predicting Grasping Affordances

    DEFF Research Database (Denmark)

    Thomsen, Mikkel Tang; Kraft, Dirk; Krüger, Norbert

    2017-01-01

    The problem of grasping unknown objects utilising vision is addressed in this work by introducing a novel feature, the Sliced Pineapple Grid Feature (SPGF). The SPGF encode semi-local surfaces and allows for distinguishing structures such as “walls”,“edges” and “rims”. These structures are shown...

  16. Water-activity of dehydrated guava slices sweeteners

    International Nuclear Information System (INIS)

    Ayub, M.; Zeb, A.; Ullah, J.

    2005-01-01

    A study was carried out to investigate the individual and combined effect of caloric sweeteners (sucrose, glucose and fructose) and non-caloric sweeteners (saccharine, cyclamate and aspartame) along with antioxidants (citric acid and ascorbic acid) and chemical preservatives (potassium metabisulphite and potassium sorbate) on the water-activity (a/sub w/) of dehydrated guava slices. Different dilutions of caloric sweeteners (20, 30, 40 and 50 degree brix (bx) and non-caloric sweeteners (equivalent to sucrose sweetness) were used. Guava slices were osmotically dehydrated in these solutions and then dehydrated initially at 0 and then at 60 degree C to final moisture-content of 20-25%. Guava slices prepared with sucrose: glucose 7:3 potassium metabisulphite, ascorbic acid and citric acid produced best quality products, which have minimum (a/sub w/) and best overall sensory characteristics. The analysis showed that treatments and their various concentrations had a significant effect (p=0.05) on (a/sub w/) of dehydrated guava slices. (author)

  17. Colour behaviour on mango ( Mangifera indica ) slices self ...

    African Journals Online (AJOL)

    The effect of the syrup composition on behaviour colour of self stabilized mango slices in glass jars by hurdle technology during 180 days of storage was studied through 26-2 fractional factorial design. L* (lightness), a* (redness and greenness), and b* (yellowness and blueness) values were measured with a colorimeter ...

  18. Three-dimensional electrode array for brain slice culture

    DEFF Research Database (Denmark)

    Vazquez Rodriguez, Patricia

    Multielektroder arrays (MEA) er rækker af elektroder mest i mikrometer størrelse, som er blevet brugt i stor omfang til at stimulere og måle elektrisk aktivitet fra neuronale netværker. Brug af disse for at analysere hjerne slices (hjerneskiver) kan give indsigt i interaktioner mellem neuroner, e...

  19. Gravitational clustering of galaxies in the CfA slice

    International Nuclear Information System (INIS)

    Crane, P.; Saslaw, W.C.

    1988-01-01

    The clustering properties of the Galaxies in the CfA slice have been analyzed by comparing the properties of the neighbor distributions to the predictions of gravitational clustering theory. The agreement is excellent and implies that the observed structures can be explained by gravitational effects alone and do not require exotic explanations

  20. Long-term brain slice culturing in a microfluidic platform

    DEFF Research Database (Denmark)

    Vedarethinam, Indumathi; Avaliani, N.; Tønnesen, J.

    2011-01-01

    In this work, we present the development of a transparent poly(methyl methacrylate) (PMMA) based microfluidic culture system for handling long-term brain slice cultures independent of an incubator. The different stages of system development have been validated by culturing GFP producing brain sli...

  1. Pyrethroid insecticides evoke neurotransmitter release from rabbit striatal slices

    International Nuclear Information System (INIS)

    Eells, J.T.; Dubocovich, M.L.

    1988-01-01

    The effects of the synthetic pyrethroid insecticide fenvalerate ([R,S]-alpha-cyano-3-phenoxybenzyl[R,S]-2-(4-chlorophenyl)-3- methylbutyrate) on neurotransmitter release in rabbit brain slices were investigated. Fenvalerate evoked a calcium-dependent release of [ 3 H]dopamine and [ 3 H]acetylcholine from rabbit striatal slices that was concentration-dependent and specific for the toxic stereoisomer of the insecticide. The release of [ 3 H]dopamine and [ 3 H]acetylcholine by fenvalerate was modulated by D2 dopamine receptor activation and antagonized completely by the sodium channel blocker, tetrodotoxin. These findings are consistent with an action of fenvalerate on the voltage-dependent sodium channels of the presynaptic membrane resulting in membrane depolarization, and the release of dopamine and acetylcholine by a calcium-dependent exocytotic process. In contrast to results obtained in striatal slices, fenvalerate did not elicit the release of [ 3 H]norepinephrine or [ 3 H]acetylcholine from rabbit hippocampal slices indicative of regional differences in sensitivity to type II pyrethroid actions

  2. Fragmentation process of vitrified ceramic waste (VCW) aiming its incorporation in silico-aluminous refractory concrete for production of refractory bricks

    International Nuclear Information System (INIS)

    Gomes, L.B.; Brandalise, R.N.; Santos, V. dos; Bergmann, C.P.

    2012-01-01

    Ceramic industry generates large amounts of waste, usually disposed in landfills. Reuse could minimize their generation and provides sustainable solutions. However, the energy cost of grinding these waste becomes a hindrance to their reuse. This work aims to obtain particle sizes of vitrified ceramic waste (VCW) using a fast, efficient and low cost fragmentation process as well as its use in refractory concrete. The results shows a wide range of particle size of VCW, which can be used as a promising source of raw material for production of refractory concrete. (author)

  3. Analysis of surface leaching processes in vitrified high-level nuclear wastes using in-situ raman imaging and atomistic modeling. 1998 annual progress report

    International Nuclear Information System (INIS)

    Clark, D.E.; Simmons, J.H.

    1998-01-01

    'The research objective was to test and develop optical methods for real-time, remote and in-situ testing of corrosion processes on the surface of vitrified nuclear wastes. This report summarizes the research conducted in the first 1.5 years of a 3 year grant. At this point, the authors have identified the conditions for optimal tests and demonstrated that both IR reflection and Raman spectroscopies can be used to determine the dealkalization process in the surface of simple glasses in real time.'

  4. A review and analysis of European industrial experience in handling LWR [light water reactor] spent fuel and vitrified high-level waste

    International Nuclear Information System (INIS)

    Blomeke, J.O.

    1988-06-01

    The industrial facilities that have been built or are under construction in France, the United Kingdom, Sweden, and West Germany to handle light-water reactor (LWR) spent fuel and canisters of vitrified high-level waste before ultimate disposal are described and illustrated with drawings and photographs. Published information on the operating performances of these facilities is also given. This information was assembled for consideration in planning and design of similar equipment and facilities needed for the Federal Waste Management System in the United States. 79 refs., 71 figs., 10 tabs

  5. Quantification of silver nanoparticle uptake and distribution within individual human macrophages by FIB/SEM slice and view.

    Science.gov (United States)

    Guehrs, Erik; Schneider, Michael; Günther, Christian M; Hessing, Piet; Heitz, Karen; Wittke, Doreen; López-Serrano Oliver, Ana; Jakubowski, Norbert; Plendl, Johanna; Eisebitt, Stefan; Haase, Andrea

    2017-03-21

    Quantification of nanoparticle (NP) uptake in cells or tissues is very important for safety assessment. Often, electron microscopy based approaches are used for this purpose, which allow imaging at very high resolution. However, precise quantification of NP numbers in cells and tissues remains challenging. The aim of this study was to present a novel approach, that combines precise quantification of NPs in individual cells together with high resolution imaging of their intracellular distribution based on focused ion beam/ scanning electron microscopy (FIB/SEM) slice and view approaches. We quantified cellular uptake of 75 nm diameter citrate stabilized silver NPs (Ag 75 Cit) into an individual human macrophage derived from monocytic THP-1 cells using a FIB/SEM slice and view approach. Cells were treated with 10 μg/ml for 24 h. We investigated a single cell and found in total 3138 ± 722 silver NPs inside this cell. Most of the silver NPs were located in large agglomerates, only a few were found in clusters of fewer than five NPs. Furthermore, we cross-checked our results by using inductively coupled plasma mass spectrometry and could confirm the FIB/SEM results. Our approach based on FIB/SEM slice and view is currently the only one that allows the quantification of the absolute dose of silver NPs in individual cells and at the same time to assess their intracellular distribution at high resolution. We therefore propose to use FIB/SEM slice and view to systematically analyse the cellular uptake of various NPs as a function of size, concentration and incubation time.

  6. Fan beam image reconstruction with generalized Fourier slice theorem.

    Science.gov (United States)

    Zhao, Shuangren; Yang, Kang; Yang, Kevin

    2014-01-01

    For parallel beam geometry the Fourier reconstruction works via the Fourier slice theorem (or central slice theorem, projection slice theorem). For fan beam situation, Fourier slice can be extended to a generalized Fourier slice theorem (GFST) for fan-beam image reconstruction. We have briefly introduced this method in a conference. This paper reintroduces the GFST method for fan beam geometry in details. The GFST method can be described as following: the Fourier plane is filled by adding up the contributions from all fanbeam projections individually; thereby the values in the Fourier plane are directly calculated for Cartesian coordinates such avoiding the interpolation from polar to Cartesian coordinates in the Fourier domain; inverse fast Fourier transform is applied to the image in Fourier plane and leads to a reconstructed image in spacial domain. The reconstructed image is compared between the result of the GFST method and the result from the filtered backprojection (FBP) method. The major differences of the GFST and the FBP methods are: (1) The interpolation process are at different data sets. The interpolation of the GFST method is at projection data. The interpolation of the FBP method is at filtered projection data. (2) The filtering process are done in different places. The filtering process of the GFST is at Fourier domain. The filtering process of the FBP method is the ramp filter which is done at projections. The resolution of ramp filter is variable with different location but the filter in the Fourier domain lead to resolution invariable with location. One advantage of the GFST method over the FBP method is in short scan situation, an exact solution can be obtained with the GFST method, but it can not be obtained with the FBP method. The calculation of both the GFST and the FBP methods are at O(N^3), where N is the number of pixel in one dimension.

  7. Modulatory action of taurine on the release of GABA in cerebellar slices of the guinea pig

    Energy Technology Data Exchange (ETDEWEB)

    Namima, M.; Okamoto, K.; Sakai, Y.

    1983-01-01

    For the purpose of demonstrating the action of taurine as a neuromodulator in addition to its suggested neurotransmitter function, the effects of taurine and muscimol on the depolarization-induced Ca-dependent release of (/sup 3/H) gamma-aminobutyric acid ((/sup 3/H)GABA) and L-(/sup 3/H)glutamate in cerebellar slices from guinea pigs were investigated. The release of (/sup 3/H)GABA was found to be greatly decreased by a GABA agonist, muscimol, and by taurine, but not by glycine. The release of L-(/sup 3/H)glutamate was little affected by taurine. The release of (/sup 3/H)GABA, was enhanced by bicuculline and strychnine, but not by picrotoxin, and the suppressive action of muscimol on the GABA release was antagonized by bicuculline, picrotoxin, and strychnine, suggesting the possible existence of presynaptic autoreceptors for GABA in the cerebellum. The suppressive action of taurine on the release of (/sup 3/H)GABA, on the other hand, was blocked only by bicuculline. These results suggest that taurine reduced the release of (/sup 3/H)GABA from cerebellar slices by acting on the GABA autoreceptors or, more likely, on other types of receptors that are sensitive to bicuculline. As a possible mechanism for this modulatory action of taurine, the blockade by this amino acid of the influx of Ca/sup 2 +/ into cerebellar tissues was tentatively suggested.

  8. [Simulation and data analysis of stereological modeling based on virtual slices].

    Science.gov (United States)

    Wang, Hao; Shen, Hong; Bai, Xiao-yan

    2008-05-01

    To establish a computer-assisted stereological model for simulating the process of slice section and evaluate the relationship between section surface and estimated three-dimensional structure. The model was designed by mathematic method as a win32 software based on the MFC using Microsoft visual studio as IDE for simulating the infinite process of sections and analysis of the data derived from the model. The linearity of the fitting of the model was evaluated by comparison with the traditional formula. The win32 software based on this algorithm allowed random sectioning of the particles distributed randomly in an ideal virtual cube. The stereological parameters showed very high throughput (>94.5% and 92%) in homogeneity and independence tests. The data of density, shape and size of the section were tested to conform to normal distribution. The output of the model and that from the image analysis system showed statistical correlation and consistency. The algorithm we described can be used for evaluating the stereologic parameters of the structure of tissue slices.

  9. Optimum slicing of radical prostatectomy specimens for correlation between histopathology and medical images

    International Nuclear Information System (INIS)

    Chen, Li Hong; Ng, Wan Sing; Ho, Henry; Yuen, John; Cheng, Chris; Lazaro, Richie; Thng, Choon Hua

    2010-01-01

    There is a need for methods which enable precise correlation of histologic sections with in vivo prostate images. Such methods would allow direct comparison between imaging features and functional or histopathological heterogeneity of tumors. Correlation would be particularly useful for validating the accuracy of imaging modalities, developing imaging techniques, assessing image-guided therapy, etc. An optimum prostate slicing method for accurate correlation between the histopathological and medical imaging planes in terms of section angle, thickness and level was sought. Literature review (51 references from 1986-2009 were cited) was done on the various sectioning apparatus or techniques used to slice the prostate specimen for accurate correlation between histopathological data and medical imaging. Technology evaluation was performed with review and discussion of various methods used to section other organs and their possible applications for sectioning prostatectomy specimens. No consensus has been achieved on how the prostate should be dissected to achieve a good correlation. Various customized sectioning instruments and techniques working with different mechanism are used in different research institutes to improve the correlation. Some of the methods have convincingly shown significant potential for improving image-specimen correlation. However, the semisolid consistent property of prostate tissue and the lack of identifiable landmarks remain challenges to be overcome, especially for fresh prostate sectioning and microtomy without external fiducials. A standardized optimum protocol to dissect prostatectomy specimens is needed for the validation of medical imaging modalities by histologic correlation. These standards can enhance disease management by improving the comparability between different modalities. (orig.)

  10. Effects of endogenous pyrogen and prostaglandin E2 on hypothalamic neurons in rat brain slices.

    Science.gov (United States)

    Watanabe, T; Morimoto, A; Murakami, N

    1987-06-01

    We investigated the effects of endogenous pyrogen and prostaglandin E2 (PGE2) on the preoptic and anterior hypothalamic (POAH) neurons using brain slice preparations from the rat. Partially purified endogenous pyrogen did not change the activities of most of the neurons in the POAH region when applied locally through a micropipette attached to the recording electrode in proximity to the neurons. This indicates that partially purified endogenous pyrogen does not act directly on the neuronal activity in the POAH region. The partially purified endogenous pyrogen, applied into a culture chamber containing a brain slice, facilitated the activities in 24% of the total neurons tested, regardless of the thermal specificity of the neurons. Moreover, PGE2 added to the culture chamber facilitated 48% of the warm-responsive, 33% of the cold-responsive, and 29% of the thermally insensitive neurons. The direction of change in neuronal activity induced by partially purified endogenous pyrogen appears to be almost the same as that induced by PGE2 when these substances were applied by perfusion to the same neuron in the culture chamber. These results suggest that partially purified pyrogen applied to the perfusate of the culture chamber stimulates some constituents of brain tissue to synthesize and release prostaglandin, which in turn affects the neuronal activity of the POAH region.

  11. Raman microscopy of freeze-dried mouse eyeball-slice in conjunction with the "in vivo cryotechnique".

    Science.gov (United States)

    Terada, Nobuo; Ohno, Nobuhiko; Saitoh, Sei; Fujii, Yasuhisa; Ohguro, Hiroshi; Ohno, Shinichi

    2007-07-01

    The wavelength of Raman-scattered light depends on the molecular composition of the substance. This is the first attempt to acquire Raman spectra of a mouse eyeball removed from a living mouse, in which the eyeball was preserved using the "in vivo cryotechnique" followed by freeze-drying. Eyeballs were cryofixed using a rapid freezing cryotechnique, and then sliced in the cryostat machine. The slices were sandwiched between glass slides, freeze-dried, and analyzed with confocal Raman microscopy. Important areas including various eyeball tissue layers were selected using bright-field microscopy, and then the Raman spectra were obtained at 240 locations. Four typical patterns of Raman spectra were electronically mapped on the specimen images obtained by the bright-field microscopy. Tissue organization was confirmed by embedding the same eyeball slice used for Raman spectra into epoxy resin and the thick sections were prepared with the inverted capsule method. Each Raman spectral pattern represents a different histological layer in the eyeball which was mapped by comparing the images of toluidine blue staining and Raman mapping with different colors. In the choroid and pigment cell layer, the Raman spectrum had two peaks, corresponding to melanin. Some of the peaks of the Raman spectra obtained from the blood vessels in sclera and the photoreceptor layer were similar to those obtained from the purified hemoglobin and rhodopsin proteins, respectively. Our experimental protocol can distinguish different tissue components with Raman microscopy; therefore, this method can be very useful for examining the distribution of a biological structures and/or chemical components in rapidly frozen freeze-dried tissue.

  12. Precision-cut kidney slices (PCKS to study development of renal fibrosis and efficacy of drug targeting ex vivo

    Directory of Open Access Journals (Sweden)

    Fariba Poosti

    2015-10-01

    Full Text Available Renal fibrosis is a serious clinical problem resulting in the greatest need for renal replacement therapy. No adequate preventive or curative therapy is available that could be clinically used to target renal fibrosis specifically. The search for new efficacious treatment strategies is therefore warranted. Although in vitro models using homogeneous cell populations have contributed to the understanding of the pathogenetic mechanisms involved in renal fibrosis, these models poorly mimic the complex in vivo milieu. Therefore, we here evaluated a precision-cut kidney slice (PCKS model as a new, multicellular ex vivo model to study the development of fibrosis and its prevention using anti-fibrotic compounds. Precision-cut slices (200-300 μm thickness were prepared from healthy C57BL/6 mouse kidneys using a Krumdieck tissue slicer. To induce changes mimicking the fibrotic process, slices were incubated with TGFβ1 (5 ng/ml for 48 h in the presence or absence of the anti-fibrotic cytokine IFNγ (1 µg/ml or an IFNγ conjugate targeted to PDGFRβ (PPB-PEG-IFNγ. Following culture, tissue viability (ATP-content and expression of α-SMA, fibronectin, collagen I and collagen III were determined using real-time PCR and immunohistochemistry. Slices remained viable up to 72 h of incubation, and no significant effects of TGFβ1 and IFNγ on viability were observed. TGFβ1 markedly increased α-SMA, fibronectin and collagen I mRNA and protein expression levels. IFNγ and PPB-PEG-IFNγ significantly reduced TGFβ1-induced fibronectin, collagen I and collagen III mRNA expression, which was confirmed by immunohistochemistry. The PKCS model is a novel tool to test the pathophysiology of fibrosis and to screen the efficacy of anti-fibrotic drugs ex vivo in a multicellular and pro-fibrotic milieu. A major advantage of the slice model is that it can be used not only for animal but also for (fibrotic human kidney tissue.

  13. Clinical lymph node staging-Influence of slice thickness and reconstruction kernel on volumetry and RECIST measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fabel, M., E-mail: m.fabel@rad.uni-kiel.de [Department of Diagnostic Radiology, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, Haus 23, D-24105 Kiel (Germany); Wulff, A., E-mail: a.wulff@rad.uni-kiel.de [Department of Diagnostic Radiology, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, Haus 23, D-24105 Kiel (Germany); Heckel, F., E-mail: frank.heckel@mevis.fraunhofer.de [Fraunhofer MeVis, Universitaetsallee 29, 28359 Bremen (Germany); Bornemann, L., E-mail: lars.bornemann@mevis.fraunhofer.de [Fraunhofer MeVis, Universitaetsallee 29, 28359 Bremen (Germany); Freitag-Wolf, S., E-mail: freitag@medinfo.uni-kiel.de [Institute of Medical Informatics and Statistics, Brunswiker Strasse 10, 24105 Kiel (Germany); Heller, M., E-mail: martin.heller@rad.uni-kiel.de [Department of Diagnostic Radiology, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, Haus 23, D-24105 Kiel (Germany); Biederer, J., E-mail: juergen.biederer@rad.uni-kiel.de [Department of Diagnostic Radiology, University Hospital Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, Haus 23, D-24105 Kiel (Germany); Bolte, H., E-mail: hendrik.bolte@ukmuenster.de [Department of Nuclear Medicine, University Hospital Muenster, Albert-Schweitzer-Campus 1, Gebaeude A1, D-48149 Muenster (Germany)

    2012-11-15

    Purpose: Therapy response evaluation in oncological patient care requires reproducible and accurate image evaluation. Today, common standard in measurement of tumour growth or shrinkage is one-dimensional RECIST 1.1. A proposed alternative method for therapy monitoring is computer aided volumetric analysis. In lung metastases volumetry proved high reliability and accuracy in experimental studies. High reliability and accuracy of volumetry in lung metastases has been proven. However, other metastatic lesions such as enlarged lymph nodes are far more challenging. The aim of this study was to investigate the reproducibility of semi-automated volumetric analysis of lymph node metastases as a function of both slice thickness and reconstruction kernel. In addition, manual long axis diameters (LAD) as well as short axis diameters (SAD) were compared to automated RECIST measurements. Materials and methods: Multislice-CT of the chest, abdomen and pelvis of 15 patients with lymph node metastases of malignant melanoma were included. Raw data were reconstructed using different slice thicknesses (1-5 mm) and varying reconstruction kernels (B20f, B40f, B60f). Volume and RECIST measurements were performed for 85 lymph nodes between 10 and 60 mm using Oncology Prototype Software (Fraunhofer MEVIS, Siemens, Germany) and were compared to a defined reference volume and diameter by calculating absolute percentage errors (APE). Variability of the lymph node sizes was computed as relative measurement differences, precision of measurements was computed as relative measurement deviation. Results: Mean absolute percentage error (APE) for volumetric analysis varied between 3.95% and 13.8% and increased significantly with slice thickness. Differences between reconstruction kernels were not significant, however, a trend towards middle soft tissue kernel could be observed.. Between automated and manual short axis diameter (SAD, RECIST 1.1) and long axis diameter (LAD, RECIST 1.0) no

  14. Clinical lymph node staging—Influence of slice thickness and reconstruction kernel on volumetry and RECIST measurements

    International Nuclear Information System (INIS)

    Fabel, M.; Wulff, A.; Heckel, F.; Bornemann, L.; Freitag-Wolf, S.; Heller, M.; Biederer, J.; Bolte, H.

    2012-01-01

    Purpose: Therapy response evaluation in oncological patient care requires reproducible and accurate image evaluation. Today, common standard in measurement of tumour growth or shrinkage is one-dimensional RECIST 1.1. A proposed alternative method for therapy monitoring is computer aided volumetric analysis. In lung metastases volumetry proved high reliability and accuracy in experimental studies. High reliability and accuracy of volumetry in lung metastases has been proven. However, other metastatic lesions such as enlarged lymph nodes are far more challenging. The aim of this study was to investigate the reproducibility of semi-automated volumetric analysis of lymph node metastases as a function of both slice thickness and reconstruction kernel. In addition, manual long axis diameters (LAD) as well as short axis diameters (SAD) were compared to automated RECIST measurements. Materials and methods: Multislice-CT of the chest, abdomen and pelvis of 15 patients with lymph node metastases of malignant melanoma were included. Raw data were reconstructed using different slice thicknesses (1–5 mm) and varying reconstruction kernels (B20f, B40f, B60f). Volume and RECIST measurements were performed for 85 lymph nodes between 10 and 60 mm using Oncology Prototype Software (Fraunhofer MEVIS, Siemens, Germany) and were compared to a defined reference volume and diameter by calculating absolute percentage errors (APE). Variability of the lymph node sizes was computed as relative measurement differences, precision of measurements was computed as relative measurement deviation. Results: Mean absolute percentage error (APE) for volumetric analysis varied between 3.95% and 13.8% and increased significantly with slice thickness. Differences between reconstruction kernels were not significant, however, a trend towards middle soft tissue kernel could be observed.. Between automated and manual short axis diameter (SAD, RECIST 1.1) and long axis diameter (LAD, RECIST 1.0) no

  15. Effect of simultaneous infrared dry-blanching and dehydration on quality characteristics of carrot slices

    Science.gov (United States)

    This study investigated the effects of various processing parameters on carrot slices exposed to infrared (IR) radiation heating for achieving simultaneous infrared dry-blanching and dehydration (SIRDBD). The investigated parameters were product surface temperature, slice thickness and processing ti...

  16. Analysis of Surface Leaching Processes in Vitrified High-Level Nuclear Wastes Using In-Situ Raman Imaging and Atomistic Modeling - Final Report

    International Nuclear Information System (INIS)

    Simmons, Joseph H.

    2001-01-01

    The in situ analysis of surface conditions of vitrified nuclear wastes can provide an important check of the burial status of radioactive objects without risk of radiation exposure. Raman spectroscopy was initially chosen as the most promising method for testing the surface conditions of glasses undergoing chemical corrosion, and was used extensively during the first year. However, it was determined that infrared reflection spectroscopy was better suited to this particular need and was used for the remaining two years to investigate the surface corrosion behavior of model silicate glasses for extension to nuclear waste glasses. The developed methodology is consistent with the known theory of optical propagation of dielectric media and uses the Kramers-Kronig formalism. The results show that it is possible to study the corrosion of glass by analyzing the glass surface using reflection fast Fourier infrared measurements and the newly developed ''dispersion analysis method.'' The data show how this analysis can be used to monitor the corrosion behavior of vitrified waste glasses over extended periods of storage

  17. Effect of apple varieties and irradiation on the quality of explosion puffed apple slices

    International Nuclear Information System (INIS)

    Bi Jinfeng; Ding Yuanyuan; Wang Pei; Bai Shasha

    2009-01-01

    Many factors affect the quality of explosion puffed apple slices. Apple varieties of Guoguang, Fuji, Hongxiangjiao and Huangxiangjiao were used as materal, the quality of fresh apple and explosion puffed products were analyzed based on the data of their physical and chemical characteristics and flavor. The results showed that Guoguang apple had the optimal flavor and Huangxiangjiao apple had the optimal product quality. So the Guoguang apple was selected as the material for the following results showed that irradiation could soften apple tissue, improve the pre-drying rate, increase products crispness, and also reduce the products hardness, but the irradiation of 2 and 5 kGy could turn products brown seriously, which reduced the product quality. (authors)

  18. Tetrahydrobiopterin precursor sepiapterin provides protection against neurotoxicity of 1-methyl-4-phenylpyridinium in nigral slice cultures

    DEFF Research Database (Denmark)

    Madsen, Jakob Torp; Jansen, Pernille; Hesslinger, Christian

    2003-01-01

    Complex-I inhibition and oxidative processes have been implicated in the loss of nigral dopamine neurones in Parkinson's disease and the toxicity of MPTP and its metabolite MPP+. Tetrahydrobiopterin, an essential cofactor for tyrosine hydroxylase, may act as an antioxidant in dopaminergic neurones...... and protects against the toxic consequences of glutathione depletion. Here we studied the effects of manipulating tetrahydrobiopterin levels on MPP+ toxicity in organotypic, rat ventral mesencephalic slice cultures. In cultures exposed to 30 micro m MPP+ for 2 days, followed by 8 days 'recovery' in control...... medium, we measured dopamine and its metabolites in the tissue and culture medium by HPLC, lactate dehydrogenase release to the culture medium, cellular uptake of propidium iodide and counted the tyrosine hydroxylase-immunoreactive neurones. Inhibition of tetrahydrobiopterin synthesis by 2,4-diamino-6...

  19. Reduction of acrylamide formation in potato slices during frying

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Kaack, K.; Granby, Kit

    2004-01-01

    and 40 min; 90degreesC for 2 and 9 min); (iii) immersed in citric acid solutions of different concentrations (10 and 20 g/l) for half an hour. Glucose and asparagine concentration was determined in potato slices before frying, whereas acrylamide content was determined in the resultant fried potato chips...... on average 76% and 68% of the glucose and asparagine content compared to the control. Potato slices blanched at 50degreesC for 70 min surprisingly had a very low acrylamide content (28 mum/kg) even when they were fried at 190degreesC. Potato immersion in citric acid solutions of 10 and 20 g/l reduced...

  20. Ethanol induces MAP2 changes in organotypic hippocampal slice cultures

    DEFF Research Database (Denmark)

    Noraberg, J; Zimmer, J

    1998-01-01

    loss of CA3 pyramidal cells and moderate loss of dentate granule cells, as seen in vivo. The results indicate that brain slice cultures combined with immunostaining for cytoskeleton and neuronal markers can be used for studies of ethanol and organic solvent neurotoxicity.......Microtubule-associated protein 2 (MAP2) and neuron-specific protein (NeuN) immunostains were used to demonstrate neurotoxic effects in mature hippocampal slice cultures exposed to ethanol (50, 100, 200 mM) for 4 weeks. At the low dose the density of MAP2 immunostaining in the dentate molecular...... layer was 118% of the control cultures, with no detectable changes in CA1 and CA3. At 100 mM no changes were detected, while 200 mM ethanol significantly reduced the MAP2 density in both dentate (19%) and hippocampal dendritic fields (CA3, 52%; CA1, 55%). At this dose NeuN staining showed considerable...

  1. Microbiological quality of sliced and block mozzarella cheese

    Directory of Open Access Journals (Sweden)

    Mariana Fontanetti Marinheiro

    2015-06-01

    Full Text Available The aim of this study was to verify the microbiological quality of mozzarella cheese sold in retail markets of Pelotas, Rio Grande do Sul, Brazil. Forty samples of mozzarella cheese were analyzed, comprising 20 samples of block cheese and 20 of sliced cheese. The cheese samples were analyzed for thermotolerant coliform counts and coagulase positive staphylococci counts, and presence of Salmonella spp and Listeria monocytogenes. The percentage of 12,5% and 5% of the sliced and block cheese samples analyzed, respectively, exceeded the microbiological standards accepted by Brazilian legislation. These results indicate the need for a better product monitoring and more concern with hygiene and sanitary practices during industrial process.

  2. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans

    Directory of Open Access Journals (Sweden)

    Alizé Lacoste Jeanson

    2017-05-01

    Full Text Available Background Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. Methods We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT and lean tissue (LT in such material. An intra-class correlation coefficient (ICC was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS linear regressions and support vector machine regression (SVMR. Results and Discussion The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5 and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77 than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08 for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  3. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans.

    Science.gov (United States)

    Lacoste Jeanson, Alizé; Dupej, Ján; Villa, Chiara; Brůžek, Jaroslav

    2017-01-01

    Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT) and lean tissue (LT) in such material. An intra-class correlation coefficient (ICC) was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS) linear regressions and support vector machine regression (SVMR). The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5) and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77) than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08) for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  4. Correlation between in vivo and in vitro pulmonary responses to jet propulsion fuel-8 using precision-cut lung slices and a dynamic organ culture system.

    Science.gov (United States)

    Hays, Allison M; Lantz, R Clark; Witten, Mark L

    2003-01-01

    In tissue slice models, interactions between the heterogeneous cell types comprising the lung parenchyma are maintained thus providing a controlled system for the study of pulmonary toxicology in vitro. However, validation of the model in vitro system must be affirmed. Previous reports, in in vivo systems, have demonstrated that Clara cells and alveolar type II cells are the targets following inhalation of JP-8 jet fuel. We have utilized the lung slice model to determine if cellular targets are similar following in vitro exposure to JP-8. Agar-filled adult rat lung explants were cored and precision cut, using the Brende/Vitron tissue slicer. Slices were cultured on titanium screens located as half-cylinders in cylindrical Teflon cradles that were loaded into standard scintillation vials and incubated at 37 degrees C. Slices were exposed to JP-8 jet fuel (0.5 mg/ml, 1.0 mg/ml, and 1.5 mg/ml in medium) for up to 24 hours. We determined ATP content using a luciferin-luciferase bioluminescent assay. No significant difference was found between the JP-8 jet fuel doses or time points, when compared to controls. Results were correlated with structural alterations following aerosol inhalation of JP-8. As a general observation, ultrastructural evaluation of alveolar type cells revealed an apparent increase in the number and size of surfactant secreting lamellar bodies that was JP-8 jet fuel-dose dependent. These results are similar to those observed following aerosol inhalation exposure. Thus, the lung tissue slice model appears to mimic in vivo effects of JP-8 and therefore is a useful model system for studying the mechanisms of lunginjury following JP-8 exposure.

  5. Comparison between powder and slices diffraction methods in teeth samples

    Energy Technology Data Exchange (ETDEWEB)

    Colaco, Marcos V.; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (IF/UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada; Porto, Isabel M. [Universidade Estadual de Campinas (FOP/UNICAMP), Piracicaba, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia; Gerlach, Raquel F. [Universidade de Sao Paulo (FORP/USP), Rieirao Preto, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia, Estomatologia e Fisiologia; Costa, Fanny N. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10{sup -1}0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  6. Analysis of aliasing artifacts in 16-slice helical CT

    International Nuclear Information System (INIS)

    Chen Wei; Liu Jingkang; Ou Xiaoguang; Li Wenzheng; Liao Weihua; Yan Ang

    2006-01-01

    Objective: To recognize the features of aliasing artifacts on CT images, and to investigate the effects of imaging parameters on the magnitude of this artifacts. Methods: An adult dry skull was placed in a plastic water-filled container and scanned with a PHILIPS 16-slice helical CT. All the acquired transaxial images by using several different acquisition or reconstruction parameters were examined for comparative assessment of the aliasing artifacts. Results: The aliasing artifacts could be seen in most instances and characterized as the spokewise patterns emanating from the edges of high contrast structure as its radius varies sharply in the longitudinal direction. The images that scanned with pitch of 0.3, 0.6 and 0.9, respectively, showed aliasing artifacts, and its severities increased with pitches escalated (detector combination 16 x 1.5, reconstruction thickness 2 mm); There were more significant aliasing artifacts on the images reconstructed with 0.8 mm slice width compared with 1-mm slice width, and no aliasing artifacts were observed on the images reconstructed with 2-mm slice width (detector combination 16 x 0.75, pitch 0.6); No artifacts were perceived on the images scanned with detector combination 16 x 0.75, while presented evidently with the use of detector combination 16 x 1.5 (pitch 0.6, reconstruction thickness 2 mm); The degrees of aliasing artifacts were unaltered when reconstruction interval and tube current changed. Conclusions: Aliasing artifacts are caused by undersampling. When the operator choose the thinner sampling thickness, lower pitch and a much wider reconstruction thickness judiciously, aliasing artifacts could be effectively mitigated or suppressed. (authors)

  7. On the concordance genus of topologically slice knots

    OpenAIRE

    Hom, Jennifer

    2012-01-01

    The concordance genus of a knot K is the minimum Seifert genus of all knots smoothly concordant to K. Concordance genus is bounded below by the 4-ball genus and above by the Seifert genus. We give a lower bound for the concordance genus of K coming from the knot Floer complex of K. As an application, we prove that there are topologically slice knots with 4-ball genus equal to one and arbitrarily large concordance genus.

  8. Comparison between powder and slices diffraction methods in teeth samples

    International Nuclear Information System (INIS)

    Colaco, Marcos V.; Barroso, Regina C.; Porto, Isabel M.; Gerlach, Raquel F.; Costa, Fanny N.

    2011-01-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10 -1 0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  9. Integrated fMRI Preprocessing Framework Using Extended Kalman Filter for Estimation of Slice-Wise Motion

    Directory of Open Access Journals (Sweden)

    Basile Pinsard

    2018-04-01

    Full Text Available Functional MRI acquisition is sensitive to subjects' motion that cannot be fully constrained. Therefore, signal corrections have to be applied a posteriori in order to mitigate the complex interactions between changing tissue localization and magnetic fields, gradients and readouts. To circumvent current preprocessing strategies limitations, we developed an integrated method that correct motion and spatial low-frequency intensity fluctuations at the level of each slice in order to better fit the acquisition processes. The registration of single or multiple simultaneously acquired slices is achieved online by an Iterated Extended Kalman Filter, favoring the robust estimation of continuous motion, while an intensity bias field is non-parametrically fitted. The proposed extraction of gray-matter BOLD activity from the acquisition space to an anatomical group template space, taking into account distortions, better preserves fine-scale patterns of activity. Importantly, the proposed unified framework generalizes to high-resolution multi-slice techniques. When tested on simulated and real data the latter shows a reduction of motion explained variance and signal variability when compared to the conventional preprocessing approach. These improvements provide more stable patterns of activity, facilitating investigation of cerebral information representation in healthy and/or clinical populations where motion is known to impact fine-scale data.

  10. Dried fruit breadfruit slices by Refractive Window™ technique

    Directory of Open Access Journals (Sweden)

    Diego F. Tirado

    2016-01-01

    Full Text Available A large amount of products are dried due several reasons as preservation, weight reduction and improvement of stability. However, on the market are not offered low-cost and high quality products simultaneously. Although there are effective methods of dehydrating foods such as freeze drying, which preserves the flavor, color and vitamins, they are poor accessibility technologies. Therefore, alternative processes are required to be efficient and economical. The aim of this research was compare drying kinetics of sliced of breadfruit (Artocarpus communis using the technique of Refractive Window® (VR with the tray drying. To carry out this study, sliced of 1 and 2 mm thick were used. Refractive window drying was performed with the water bath temperature to 92 °C; and tray drying at 62 °C and an air velocity of 0.52 m/s. During the Refractive window drying technique, the moisture content reached the lower than tray drying levels. Similarly it happened with samples of 1 mm, which, having a smaller diameter reached lower moisture levels than samples 2 mm. The higher diffusivities were obtained during drying sliced VR 1 and 2 mm with coefficients of 6.13 and 3.90*10-9 m2/s respectively.

  11. Development of an electrically operated cassava slicing machine

    Directory of Open Access Journals (Sweden)

    I. S. Aji

    2013-08-01

    Full Text Available Labor input in manual cassava chips processing is very high and product quality is low. This paper presents the design and construction of an electrically operated cassava slicing machine that requires only one person to operate. Efficiency, portability, ease of operation, corrosion prevention of slicing component of the machine, force required to slice a cassava tuber, capacity of 10 kg/min and uniformity in the size of the cassava chips were considered in the design and fabrication of the machine. The performance of the machine was evaluated with cassava of average length and diameter of 253 mm and 60 mm respectively at an average speed of 154 rpm. The machine produced 5.3 kg of chips of 10 mm length and 60 mm diameter in 1 minute. The efficiency of the machine was 95.6% with respect to the quantity of the input cassava. The chips were found to be well chipped to the designed thickness, shape and of generally similar size. Galvanized steel sheets were used in the cutting section to avoid corrosion of components. The machine is portable and easy to operate which can be adopted for cassava processing in a medium size industry.

  12. Drying of carrot slices in a triple pass solar dryer

    Directory of Open Access Journals (Sweden)

    Seshachalam Kesavan

    2017-01-01

    Full Text Available An indirect triple pass forced convection solar dryer was developed and its performance was evaluated for drying of carrot slices. The drying experiments were carried out under the meteorological conditions of Coimbatore city in India during the year 2016. The experimental set-up consists of a blower, triple pass packed bed air collector (using sand with wire mesh absorber plate, and a drying chamber. The air mass flow rate was optimized to 0.062 kg/s. The initial moisture content of the carrot slices was reduced from 87.5% (on wet basis to the final moisture content of 10% (wet basis in 6 h duration. The thin layer drying characteristics were analyzed using twelve mathematical models available in open literature. The results showed that the pick-up efficiency of the dryer was varied in the range between 14 and 43% with an average air collector thermal efficiency of 44% during the experimentation. The drying characteristics of carrot slices was predicted with good degree of accuracy using Wang and Singh drying model.

  13. Determination of the Structure of Vitrified Hydroceramic/CBC Waste Form Glasses Manufactured from DOE Reprocessing Waste

    International Nuclear Information System (INIS)

    Scheetz, B.E.; White, W. B.; Chesleigh, M.; Portanova, A.; Olanrewaju, J.

    2005-01-01

    The selection of a glass-making option for the solidification of nuclear waste has dominated DOE waste form programs since the early 1980's. Both West Valley and Savannah River are routinely manufacturing glass logs from the high level waste inventory in tank sludges. However, for some wastes, direct conversion to glass is clearly not the optimum strategy for immobilization. INEEL, for example, has approximately 4400 m 3 of calcined high level waste with an activity that produces approximately 45 watts/m 3 , a rather low concentration of radioactive constituents. For these wastes, there is value in seeking alternatives to glass. An alternative approach has been developed and the efficacy of the process demonstrated that offers a significant savings in both human health and safety exposures and also a lower cost relative to the vitrification option. The alternative approach utilizes the intrinsic chemical reactivity of the highly alkaline waste with the addition of aluminosilicate admixtures in the appropriate proportions to form zeolites. The process is one in which a chemically bonded ceramic is produced. The driving force for reaction is derived from the chemical system itself at very modest temperatures and yet forms predominantly crystalline phases. Because the chemically bonded ceramic requires an aqueous medium to serve as a vehicle for the chemical reaction, the proposed zeolite-containing waste form can more adequately be described as a hydroceramic. The hydrated crystalline materials are then subject to hot isostatic pressing (HIP) which partially melts the material to form a glass ceramic. The scientific advantages of the hydroceramic/CBC approach are: (1) Low temperature processing; (2) High waste loading and thus only modest volumetric bulking from the addition of admixtures; (3) Ability to immobilize sodium; (4) Ability to handle low levels of nitrate (2-3% NO 3 - ); (5) The flexibility of a vitrifiable waste; and (6) A process that is based on an

  14. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  15. Transverse Slicing of the Sixth-Seventh Costal Cartilaginous Junction: A Novel Technique to Prevent Warping in Nasal Surgery.

    Science.gov (United States)

    Teshima, Tara Lynn; Cheng, Homan; Pakdel, Amir; Kiss, Alex; Fialkov, Jeffrey A

    2016-01-01

    Costal cartilage is an important reconstructive tissue for correcting nasal deformities. Warping of costal cartilage, a recognized complication, can lead to significant functional and aesthetic problems. The authors present a technique to prevent warping that involves transverse slicing of the sixth-seventh costal cartilaginous junction, that when sliced perpendicular to the long axis of the rib, provides multiple long, narrow, clinically useful grafts with balanced cross-sections. The aim was to measure differences in cartilage warp between this technique (TJS) and traditional carving techniques. Costal cartilage was obtained from human subjects and cut to clinically relevant dimensions using a custom cutting jig. The sixth-seventh costal cartilaginous junction was sliced transversely leaving the outer surface intact. The adjacent sixth rib cartilage was carved concentrically and eccentrically. The samples were incubated and standardized serial photography was performed over time up to 4 weeks. Warp was quantified by measuring nonlinearity of the grafts using least-squares regression and compared between carving techniques. TJS grafts (n = 10) resulted in significantly less warp than both eccentrically (n = 3) and concentrically carved grafts (n = 3) (P < 0.0001). Warp was significantly higher with eccentric carving compared with concentric carving (P < 0.0001). Warp increased significantly with time for both eccentric (P = 0002) and concentric (P = 0.0007) techniques while TJS warp did not (P = 0.56). The technique of transverse slicing costal cartilage from the sixth-seventh junction minimizes warp compared with traditional carving methods providing ample grafts of adequate length and versatility for reconstructive requirements.

  16. Changes in medium radioactivity and composition accompany high-affinity uptake of glutamate and aspartate by mouse brain slices

    International Nuclear Information System (INIS)

    Latzkovits, L.; Neidle, A.; Lajtha, A.

    1984-01-01

    In measurements of high affinity transport in tissue slices, the incubation medium is often treated as an ''infinitely large pool''. External substrate concentrations, even at the micromolar level, are assumed to be constant and metabolic interactions between tissue and medium are neglected. In the present report we describe experiments in which glutamic and aspartic acid uptake by mouse brain slices were studied using techniques that could test these assumptions. Cerebral hemispheres were cut into 0.1 mm sections and about 90 mg of tissue incubated in 10 ml of oxygenated medium. After 45 minutes of equilibration, radioactive substrates were added and the concentrations and specific activities of the amino acids and their metabolites in the medium were determined. During the first 10 min following substrate addition, rapid decreases in glutamic and aspartic acid concentrations in the medium were accompanied by large decreases in specific activity caused by the continuous release of these amino acids from the tissue. In addition, extensive conversion of both substrates to glutamine and the preferential accumulation of this metabolite, in the medium, was found. These results demonstrate that metabolism and release occur simultaneously with uptake during transport experiments in vitro and that these processes can take place in specific tissue compartments. It is therefore necessary to measure the tissue and medium concentration levels of amino acids along with their radioactivity in such experiments, since all three processes (transport, metabolism, and compartmentation) are interrelated in the clearance of amino acids from the incubation medium and probably from the extracellular spaces in vivo as well

  17. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-01-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  18. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-03-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  19. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  20. Verification of Vitrified High-Activity Waste Stored in a CASTOR HAW 20/28 CG Cask by Simulated Baseline Comparison

    International Nuclear Information System (INIS)

    Shephard, A.; Arenas-Carrasco, J.; Dratschmidt, H.; De-Baere, P.; Af Ekenstam, G.; Lebrun, A.

    2010-01-01

    The verification process for the vitrification of high-activity waste (HAW) focuses on maintaining the continuity-of-knowledge of special nuclear material (SNM) as it traverses a vitrification facility. However, the inaccessible nature of a vitrification facility presents an obstacle to the deployment of conventional safeguards, albeit the process area of a vitrification facility is effectively a hot cell. The employment of remotely operated NDA hardware/DA sample equipment inside the process area would be problematic-at-best and the alternative of continuous monitoring would draw heavily on the critical resource of inspector time. In response to the aforementioned constraints, the IAEA and Euratom opted to develop a new method which focuses on the verification of SNM after the vitrified HAW has been sealed in storage casks. The new method verifies the presence of the vitrified HAW through the comparison of total neutron count rates collected at points around a cask with those predicted by Monte Carlo simulation. The model includes a dual N50 neutron slab detector (custom design by Euratom) and a CASTOR HAW 20/28 CG storage cask configured with the operator declared contents. By comparison of the simulated neutron emission pattern and field measurements, the displacement of Pu and U is evident from a detectable neutron signal defect. Because the spontaneous fission of 244 Cm is the dominant neutron source in vitrified HAW, the 244 Cm/Pu and 244 Cm/U mass ratios must be known in order to relate the neutron signal outside the cask to the amounts of Pu and U stored inside. These mass ratios can be determined from HAW samples collected by the inspectorates from the accountability tanks and analyzed by DA. The absence of separation of SNM from the HAW is verified by other measures. To ensure the validity of the simulation, sources of uncertainty were systematically addressed and quantified. This new verification method effectively removes the need for NDA equipment

  1. The importance of mobile fission products for long-term safety in the case of disposal of vitrified high-level waste and spent fuel in a clay formation

    International Nuclear Information System (INIS)

    Marivoet, J.; Weetjens, E.

    2009-01-01

    In Belgium, the possibility to dispose of high-level radioactive waste in clay formations is studied since 1976. In the PAGIS report, which was the first performance assessment of the disposal of vitrified high-level waste in a clay formation and which was published in 1988, the most important contributors to the total dose via a water well pathway were 237 Np, 135 Cs and 99 Tc. Since 1988, several elements that strongly influence the calculated doses have evolved:?the inventory of long-lived mobile fission and activation products in vitrified high-level waste has been improved; the half-life of 79 Se has been re-estimated; substantial progress has been made in the determination of migration parameters of the main fission and activation products and actinides. In recent performance assessments, the actinides and 135 Cs do not significantly contribute to the total dose, as they remain confined in the host clay formation during several millions of years due to sorption on clay minerals. Consequently, the total dose resulting from the disposal of vitrified high-level waste or spent fuel is essentially due to releases of mobile fission and activation products. On the basis of recent waste inventory data and parameter values, the most important contributors to the total dose via a water well are: in the case of disposal of spent fuel: 79 Se, 129 I, 126 Sn, 36 Cl, and 99 Tc; in the case of disposal of vitrified HLW: 79 Se, 126 Sn, 36 Cl, 129 I, and 99 Tc. Important remaining uncertainties are the transfer factors of volatile fission and activation products into the vitrified waste during reprocessing and migration parameters of Se. (author)

  2. Fourier analysis of heart SPECT slices: from remodelation to function?

    International Nuclear Information System (INIS)

    Zigman, M.; Prpic, H.; Lokner, V.

    1994-01-01

    The aim of this study was to determine character of the spatial distribution of marked erythrocytes in heart chambers, lungs and great blood vessels in relation to function of the left and right heart. Investigation included total of 142 subjects, 28 of which were without subjective and clinical signs of heart disease as well as 56 after myocardial infarction (30 of anterior localization, 26 of inferior infarction), 35 with predominant left heart disease (aortic valve disease, dilatative myocardiopathy, etc.) and 23 with predominant right heart disease (atrial septal defect, mitral valve disease). Radionuclide ventriculography (RNV) at rest, and thorax SPECT were performed in all subjects with 740 MBq Tc-99m after in vivo erythrocyte labelling with pyrophosphate. Ultrasound investigation was performed on all the subjects with heart disease and 87 of them underwent invasive cardiac investigation. RNV analysis revealed scintigraphic data on left and right ventricle: global ejection fraction (GEF), end-systolic volume (ESV), end-diastolic volume (EDV), fast tilling rate (FFR), fast emptying rate (FER) as well as regional wall motion shortening. Reconstruction of 64x64x8 SPECT images resulted in 3x64 slices (transversal, coronal and sagittal slices). Fourier analysis of 20-32 reconstructed slices in all three dimensions gave amplitude image of the intensity distribution of marked erythrocytes in heart chambers lungs and great blood vessels as well as phase display of spatial localization of regional amplitude values. Results of joint ROC curves constructed for detection, localization and character of heart disease in all subjects revealed significant clinical information content of SPECT data. Evaluation of RI retention using amplitude images in 3D provides insight in regional changes of volume, particular for atrial and lung involvement. (author)

  3. Improved sliced velocity map imaging apparatus optimized for H photofragments.

    Science.gov (United States)

    Ryazanov, Mikhail; Reisler, Hanna

    2013-04-14

    Time-sliced velocity map imaging (SVMI), a high-resolution method for measuring kinetic energy distributions of products in scattering and photodissociation reactions, is challenging to implement for atomic hydrogen products. We describe an ion optics design aimed at achieving SVMI of H fragments in a broad range of kinetic energies (KE), from a fraction of an electronvolt to a few electronvolts. In order to enable consistently thin slicing for any imaged KE range, an additional electrostatic lens is introduced in the drift region for radial magnification control without affecting temporal stretching of the ion cloud. Time slices of ∼5 ns out of a cloud stretched to ⩾50 ns are used. An accelerator region with variable dimensions (using multiple electrodes) is employed for better optimization of radial and temporal space focusing characteristics at each magnification level. The implemented system was successfully tested by recording images of H fragments from the photodissociation of HBr, H2S, and the CH2OH radical, with kinetic energies ranging from 3 eV. It demonstrated KE resolution ≲1%-2%, similar to that obtained in traditional velocity map imaging followed by reconstruction, and to KE resolution achieved previously in SVMI of heavier products. We expect it to perform just as well up to at least 6 eV of kinetic energy. The tests showed that numerical simulations of the electric fields and ion trajectories in the system, used for optimization of the design and operating parameters, provide an accurate and reliable description of all aspects of system performance. This offers the advantage of selecting the best operating conditions in each measurement without the need for additional calibration experiments.

  4. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  5. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  6. Evaluation of methylmercury biotransformation using rat liver slices

    Energy Technology Data Exchange (ETDEWEB)

    Yasutake, A. [Biochemistry Section, National Inst. for Minamata Disease, Minamata, Kumamoto (Japan); Hirayama, K. [Kumamoto University College of Medical Science, Kuhonji (Japan)

    2001-09-01

    To examine the demethylation reaction of methylmercury (MeHg) in rat liver, slices prepared from MeHg-treated rats were incubated in L-15 medium under 95% O{sub 2}/5% CO{sub 2} atmosphere. During the incubation, the amount of inorganic Hg in the slices markedly increased in a time-dependent manner, although the concentration of total Hg remained unchanged. Since the C-Hg bond in MeHg was demonstrated to be cleaved by the action of some reactive oxygen species, the effects on MeHg demethylation of several reagents that could modify reactive oxygen production were examined in the present system. Methylviologen was found to be an effective enhancer of the demethylation reaction with only a minor effect on lipid peroxidation. On the other hand, ferrous ion added to the medium showed no effect on demethylation in the presence or absence of methylviologen, although lipid peroxide levels were increased significantly by ferrous ion. Similarly, deferoxamine mesylate, which effectively suppressed the increase in lipid peroxide levels, also had no effect on demethylation. Furthermore, hydroxy radical scavengers, such as mannitol and dimethylsulfoxide, had no effect on inorganic Hg production. Rotenone, an inhibitor of complex I in the mitochondrial electron transport system, increased levels of both inorganic Hg and lipid peroxide. However, other inhibitors, such as antimycin A, myxothiazole and NaCN, significantly suppressed the demethylation reaction. Cell fractionation of the MeHg-treated rat liver revealed that the ratio of inorganic Hg to total Hg was highest in the mitochondrial fraction. Furthermore, superoxide anion could degrade MeHg in an organic solvent but not in water. These results suggested that the demethylation of MeHg by the liver slice would proceed with the aid of superoxide anion produced in the electron transfer system at the hydrophobic mitochondrial inner membrane. Furthermore, the involvement of hydroxy radicals, which have been demonstrated to be

  7. Transverse-Longitudinal Coupling Effect in Laser Bunch Slicing

    International Nuclear Information System (INIS)

    Shimada, M.; Katoh, M.; Adachi, M.; Kimura, S.; Tanikawa, T.; Hosaka, M.; Yamamoto, N.; Takashima, Y.; Takahashi, T.

    2009-01-01

    We report turn-by-turn observation of coherent synchrotron radiation (CSR) produced by the laser bunch slicing technique at an electron storage ring operated with a small momentum compaction factor. CSR emission was intermittent, and its interval depended strongly on the betatron tune. This peculiar behavior of the CSR could be interpreted as a result of coupling between the transverse and longitudinal motion of the electrons. This is the first observation of such an effect, which would be important not only for controlling the CSR emission but also for generating and transporting ultrashort electron bunches or electron bunches with microdensity structures in advanced accelerators.

  8. Trimethyltin (TMT) neurotoxicity in organotypic rat hippocampal slice cultures

    DEFF Research Database (Denmark)

    Noraberg, J; Gramsbergen, J B; Fonnum, F

    1998-01-01

    ) propidium iodide (PI) uptake, (b) lactate dehydrogenase (LDH) efflux into the culture medium, (c) cellular cobalt uptake as an index of calcium influx, (d) ordinary Nissl cell staining, and (e) immunohistochemical staining for microtubule-associated protein 2 (MAP-2). Cellular degeneration as assessed...... to in vivo cell stain observations of rats acutely exposed to TMT. The mean PI uptake of the cultures and the LDH efflux into the medium were highly correlated. The combined results obtained by the different markers indicate that the hippocampal slice culture method is a feasible model for further studies...

  9. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W.; Klotz, E.; Ditt, H.

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs eff. , using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue. (orig.)

  10. Functional Stem Cell Integration into Neural Networks Assessed by Organotypic Slice Cultures.

    Science.gov (United States)

    Forsberg, David; Thonabulsombat, Charoensri; Jäderstad, Johan; Jäderstad, Linda Maria; Olivius, Petri; Herlenius, Eric

    2017-08-14

    Re-formation or preservation of functional, electrically active neural networks has been proffered as one of the goals of stem cell-mediated neural therapeutics. A primary issue for a cell therapy approach is the formation of functional contacts between the implanted cells and the host tissue. Therefore, it is of fundamental interest to establish protocols that allow us to delineate a detailed time course of grafted stem cell survival, migration, differentiation, integration, and functional interaction with the host. One option for in vitro studies is to examine the integration of exogenous stem cells into an existing active neural network in ex vivo organotypic cultures. Organotypic cultures leave the structural integrity essentially intact while still allowing the microenvironment to be carefully controlled. This allows detailed studies over time of cellular responses and cell-cell interactions, which are not readily performed in vivo. This unit describes procedures for using organotypic slice cultures as ex vivo model systems for studying neural stem cell and embryonic stem cell engraftment and communication with CNS host tissue. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  11. Time- and dose-dependent changes in neuronal activity produced by X radiation in brain slices

    International Nuclear Information System (INIS)

    Pellmar, T.C.; Schauer, D.A.; Zeman, G.H.

    1990-01-01

    A new method of exposing tissues to X rays in a lead Faraday cage has made it possible to examine directly radiation damage to isolated neuronal tissue. Thin slices of hippocampus from brains of euthanized guinea pigs were exposed to 17.4 ke V X radiation. Electrophysiological recordings were made before, during, and after exposure to doses between 5 and 65 Gy at a dose rate of 1.54 Gy/min. Following exposure to doses of 40 Gy and greater, the synaptic potential was enhanced, reaching a steady level soon after exposure. The ability of the synaptic potential to generate a spike was reduced and damage progressed after termination of the radiation exposure. Recovery was not observed following termination of exposure. These results demonstrate that an isolated neuronal network can show complex changes in electrophysiological properties following moderate doses of ionizing radiation. An investigation of radiation damage directly to neurons in vitro will contribute to the understanding of the underlying mechanisms of radiation-induced nervous system dysfunction

  12. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    International Nuclear Information System (INIS)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M.; Wagstaff, Anne W.; Smeltzer, Matthew P.; Krafft, Axel J.; Hankins, Jane S.

    2017-01-01

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  13. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Wagstaff, Anne W. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Rhodes College, Memphis, TN (United States); University of Alabama at Birmingham School of Medicine, Birmingham, AL (United States); Smeltzer, Matthew P. [St. Jude Children' s Research Hospital, Department of Biostatistics, Memphis, TN (United States); University of Memphis, Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, Memphis, TN (United States); Krafft, Axel J. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); University Hospital Center Freiburg, Department of Radiology, Freiburg (Germany); Hankins, Jane S. [St. Jude Children' s Research Hospital, Department of Hematology, Memphis, TN (United States)

    2017-01-15

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  14. Projection-slice theorem based 2D-3D registration

    Science.gov (United States)

    van der Bom, M. J.; Pluim, J. P. W.; Homan, R.; Timmer, J.; Bartels, L. W.

    2007-03-01

    In X-ray guided procedures, the surgeon or interventionalist is dependent on his or her knowledge of the patient's specific anatomy and the projection images acquired during the procedure by a rotational X-ray source. Unfortunately, these X-ray projections fail to give information on the patient's anatomy in the dimension along the projection axis. It would be very profitable to provide the surgeon or interventionalist with a 3D insight of the patient's anatomy that is directly linked to the X-ray images acquired during the procedure. In this paper we present a new robust 2D-3D registration method based on the Projection-Slice Theorem. This theorem gives us a relation between the pre-operative 3D data set and the interventional projection images. Registration is performed by minimizing a translation invariant similarity measure that is applied to the Fourier transforms of the images. The method was tested by performing multiple exhaustive searches on phantom data of the Circle of Willis and on a post-mortem human skull. Validation was performed visually by comparing the test projections to the ones that corresponded to the minimal value of the similarity measure. The Projection-Slice Theorem Based method was shown to be very effective and robust, and provides capture ranges up to 62 degrees. Experiments have shown that the method is capable of retrieving similar results when translations are applied to the projection images.

  15. Stimulation of estradiol biosynthesis by tributyltin in rat hippocampal slices.

    Science.gov (United States)

    Munetsuna, Eiji; Hattori, Minoru; Yamazaki, Takeshi

    2014-01-01

    Hippocampal functions are influenced by steroid hormones, such as testosterone and estradiol. It has been demonstrated that hippocampus-derived steroid hormones play important roles in neuronal protection and synapse formation. Our research groups have demonstrated that estradiol is de novo synthesized in the rat hippocampus. However, the mechanism(s) regulating this synthesis remains unclear. It has been reported that tributyltin, an environmental pollutant, binds to the retinoid X receptor (RXR) and modifies estrogen synthesis in human granulosa-like tumor cells. This compound can penetrate the blood brain barrier, and tends to accumulate in the brain. Based on these facts, we hypothesized that tributyltin could influence the hippocampal estradiol synthesis. A concentration of 0.1 μM tributyltin induced an increase in the mRNA content of P450(17α) and P450arom in hippocampal slices, as determined using real-time PCR. The transcript levels of other steroidogenic enzymes and a steroidogenic acute regulatory protein were not affected. The estradiol level in rat hippocampal slices was subsequently determined using a radioimmunoassay. We found that the estradiol synthesis was stimulated by ∼2-fold following a 48-h treatment with 0.1 μM tributyltin, and this was accompanied by transcriptional activation of P450(17α) and P450arom. Tributyltin stimulated de novo hippocampal estradiol synthesis by modifying the transcription of specific steroidogenic enzymes.

  16. Filter and slice thickness selection in SPECT image reconstruction

    International Nuclear Information System (INIS)

    Ivanovic, M.; Weber, D.A.; Wilson, G.A.; O'Mara, R.E.

    1985-01-01

    The choice of filter and slice thickness in SPECT image reconstruction as function of activity and linear and angular sampling were investigated in phantom and patient imaging studies. Reconstructed transverse and longitudinal spatial resolution of the system were measured using a line source in a water filled phantom. Phantom studies included measurements of the Data Spectrum phantom; clinical studies included tomographic procedures in 40 patients undergoing imaging of the temporomandibular joint. Slices of the phantom and patient images were evaluated for spatial of the phantom and patient images were evaluated for spatial resolution, noise, and image quality. Major findings include; spatial resolution and image quality improve with increasing linear sampling frequencies over the range of 4-8 mm/p in the phantom images, best spatial resolution and image quality in clinical images were observed at a linear sampling frequency of 6mm/p, Shepp and Logan filter gives the best spatial resolution for phantom studies at the lowest linear sampling frequency; smoothed Shepp and Logan filter provides best quality images without loss of resolution at higher frequencies and, spatial resolution and image quality improve with increased angular sampling frequency in the phantom at 40 c/p but appear to be independent of angular sampling frequency at 400 c/p

  17. Slices: A shape-proxy based on planar sections

    KAUST Repository

    McCrae, James

    2011-12-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours of intersection of planes with a 3D object, for creating shape abstractions, motivated by their popularity in art and engineering. We first perform a user study to show that humans do define consistent and similar planar section proxies for common objects. Interestingly, we observe a strong correlation between user-defined planes and geometric features of objects. Further we show that the problem of finding the minimum set of planes that capture a set of 3D geometric shape features is both NP-hard and not always the proxy a user would pick. Guided by the principles inferred from our user study, we present an algorithm that progressively selects planes to maximize feature coverage, which in turn influence the selection of subsequent planes. The algorithmic framework easily incorporates various shape features, while their relative importance values are computed and validated from the user study data. We use our algorithm to compute planar slices for various objects, validate their utility towards object abstraction using a second user study, and conclude showing the potential applications of the extracted planar slice shape proxies.

  18. X-radiography of slices of the Allende Meteorite

    Science.gov (United States)

    Smith, M. J.; Anderson, J. B.; Heymann, D.

    1984-01-01

    A 2.2 kg fragment of the Allende Meteorite was derinded and sliced by bandsawing. Several X-radiographs were made of all slices. The following features are resolved: grains of blocky troilite (bright spots), troilite rimmed chondrules (bright halos), chondrules with central vugs (dim halos), white aggregates (dark patches), and dark inclusions (medium dark patches). The number of FeS grains larger than about 0.5 mm is one per 6 + or - 1 gram of this fragment. Their concentration appears to be uniform at the 1 kg weight level, but is not uniform at the 100 g level. The number of FeS rimmed chondrules is one per 10 g. Their concentration is also nonuniform at the 100 g weight level. The number of white aggregates is roughly one per 20 g. These disc shaped objects show a distinct preferred orientation of the axis orthogonal to the plane of the disc. Chondrules with central vugs are numerous. Linear and curved arrays of chondrules, up to a few cm long, were observed. An interpretation of the observed features is given.

  19. Absence of synaptic regulation by phosducin in retinal slices.

    Directory of Open Access Journals (Sweden)

    James H Long

    Full Text Available Phosducin is an abundant photoreceptor protein that binds G-protein βγ subunits and plays a role in modulating synaptic transmission at photoreceptor synapses under both dark-adapted and light-adapted conditions in vivo. To examine the role of phosducin at the rod-to-rod bipolar cell (RBC synapse, we used whole-cell voltage clamp recordings to measure the light-evoked currents from both wild-type (WT and phosducin knockout (Pd(-/- RBCs, in dark- and light-adapted retinal slices. Pd(-/- RBCs showed smaller dim flash responses and steeper intensity-response relationships than WT RBCs, consistent with the smaller rod responses being selectively filtered out by the non-linear threshold at the rod-to-rod bipolar synapse. In addition, Pd(-/- RBCs showed a marked delay in the onset of the light-evoked currents, similar to that of a WT response to an effectively dimmer flash. Comparison of the changes in flash sensitivity in the presence of steady adapting light revealed that Pd(-/- RBCs desensitized less than WT RBCs to the same intensity. These results are quantitatively consistent with the smaller single photon responses of Pd(-/- rods, owing to the known reduction in rod G-protein expression levels in this line. The absence of an additional synaptic phenotype in these experiments suggests that the function of phosducin at the photoreceptor synapse is abolished by the conditions of retinal slice recordings.

  20. Vitrification and xenografting of human ovarian tissue.

    Science.gov (United States)

    Amorim, Christiani Andrade; Dolmans, Marie-Madeleine; David, Anu; Jaeger, Jonathan; Vanacker, Julie; Camboni, Alessandra; Donnez, Jacques; Van Langendonckt, Anne

    2012-11-01

    To assess the efficiency of two vitrification protocols to cryopreserve human preantral follicles with the use of a xenografting model. Pilot study. Gynecology research unit in a university hospital. Ovarian biopsies were obtained from seven women aged 30-41 years. Ovarian tissue fragments were subjected to one of three cryopreservation protocols (slow freezing, vitrification protocol 1, and vitrification protocol 2) and xenografted for 1 week to nude mice. The number of morphologically normal follicles after cryopreservation and grafting and fibrotic surface area were determined by histologic analysis. Apoptosis was assessed by the TUNEL method. Morphometric analysis of TUNEL-positive surface area also was performed. Follicle proliferation was evaluated by immunohistochemistry. After xenografting, a difference was observed between the cryopreservation procedures applied. According to TUNEL analysis, both vitrification protocols showed better preservation of preantral follicles than the conventional freezing method. Moreover, histologic evaluation showed a significantly higher proportion of primordial follicles in vitrified (protocol 2)-warmed ovarian tissue than in frozen-thawed tissue. The proportion of growing follicles and fibrotic surface area was similar in all groups. Vitrification procedures appeared to preserve not only the morphology and survival of preantral follicles after 1 week of xenografting, but also their ability to resume folliculogenesis. In addition, vitrification protocol 2 had a positive impact on the quiescent state of primordial follicles after xenografting. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT

    International Nuclear Information System (INIS)

    Flohr, T.; Ohnesorge, B.; Stierstorfer, K.

    2005-01-01

    The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging [de

  2. Tissue refractometry using Hilbert phase microscopy.

    Science.gov (United States)

    Lue, Niyom; Bewersdorf, Joerg; Lessard, Mark D; Badizadegan, Kamran; Dasari, Ramachandra R; Feld, Michael S; Popescu, Gabriel

    2007-12-15

    We present, for the first time to our knowledge, quantitative phase images associated with unstained 5 mum thick tissue slices of mouse brain, spleen, and liver. The refractive properties of the tissue are retrieved in terms of the average refractive index and its spatial variation. We find that the average refractive index varies significantly with tissue type, such that the brain is characterized by the lowest value and the liver by the highest. The spatial power spectra of the phase images reveal power law behavior with different exponents for each tissue type. This approach opens a new possibility for stain-free characterization of tissues, where the diagnostic power is provided by the intrinsic refractive properties of the biological structure. We present results obtained for liver tissue affected by a lysosomal storage disease and show that our technique can quantify structural changes during this disease development.

  3. The clinical efficacy of 1 mm-slice CT of the middle ear

    International Nuclear Information System (INIS)

    Noda, Kazuhiro; Noiri, Teruhisa; Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-01-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  4. Real-time slicing algorithm for Stereolithography (STL) CAD model applied in additive manufacturing industry

    Science.gov (United States)

    Adnan, F. A.; Romlay, F. R. M.; Shafiq, M.

    2018-04-01

    Owing to the advent of the industrial revolution 4.0, the need for further evaluating processes applied in the additive manufacturing application particularly the computational process for slicing is non-trivial. This paper evaluates a real-time slicing algorithm for slicing an STL formatted computer-aided design (CAD). A line-plane intersection equation was applied to perform the slicing procedure at any given height. The application of this algorithm has found to provide a better computational time regardless the number of facet in the STL model. The performance of this algorithm is evaluated by comparing the results of the computational time for different geometry.

  5. The clinical efficacy of 1 mm-slice CT of the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Noda, Kazuhiro; Noiri, Teruhisa [Kawanishi Municipal Hospital, Hyogo (Japan); Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-02-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  6. A comparative risk assessment for Listeria monocytogenes in prepackaged versus retail-sliced deli meat.

    Science.gov (United States)

    Endrikat, Sarah; Gallagher, Daniel; Pouillot, Régis; Hicks Quesenberry, Heather; Labarre, David; Schroeder, Carl M; Kause, Janell

    2010-04-01

    Deli meat was ranked as the highest-risk ready-to-eat food vehicle of Listeria monocytogenes within the 2003 U.S. Food and Drug Administration and U.S. Department of Agriculture, Food Safety and Inspection Service risk assessment. The comparative risk of L. monocytogenes in retail-sliced versus prepackaged deli meats was evaluated with a modified version of this model. Other research has found that retail-sliced deli meats have both higher prevalence and levels of L. monocytogenes than have product sliced and packaged at the manufacturer level. The updated risk assessment model considered slicing location as well as the use of growth inhibitors. The per annum comparative risk ratio for the number of deaths from retail-sliced versus prepackaged deli meats was found to be 4.89, and the per-serving comparative risk ratio was 4.27. There was a significant interaction between the use of growth inhibitors and slicing location. Almost 70% of the estimated deaths occurred from retail-sliced product that did not possess a growth inhibitor. A sensitivity analysis, assessing the effect of the model's consumer storage time and shelf life assumptions, found that even if retail-sliced deli meats were stored for a quarter of the time prepackaged deli meats were stored, retail-sliced product is 1.7 times more likely to result in death from listeriosis. Sensitivity analysis also showed that the shelf life assumption had little effect on the comparative risk ratio.

  7. Quality assessment and shelf life modeling of pulsed electric field pretreated osmodehydrofrozen kiwifruit slices

    Directory of Open Access Journals (Sweden)

    Efimia Dermesonlouoglou

    2018-04-01

    Full Text Available The objective of this workwas to investigate the potential use of pulsed electric field (PEF in combination with osmotic dehydration (OD as a pre-freezing step and to evaluate the effect on quality characteristics and shelf life of frozen kiwifruit. Peeled kiwifruit was subjected to PEF (1.8 kV/cm, sliced and treated in OD-solution [containing glycerol, maltodextrin, trehalose, ascorbic acid, calcium chloride, citric acid, sodium chloride; 1/5 (wfruit/wsolution] for 30 and 60 min at 35 °C. Combined, PEF only and OD only treated samples as well as nontreated and blanched (80 °C, 60 s samples were frozen and stored at constant (-5, -10, -15, -25 °C and dynamic temperature conditions (-18 °C-3 d, -8 °C-2.5 d, -15 °C-3 d. Quality of frozen samples was evaluated by means of drip loss, colour, texture, vitamin C and sensory evaluation (1-9 scale; and shelf life (SL was calculated. Nontreated and blanched samples presented high drip loss and tissue softening (instrumentally measured as Fmax decrease. The tissue integrity was well retained in all osmotically pretreated samples. PEF pretreatment caused increase of fruit whiteness (increase of L value and yellowness (a and/or b value increase; SL calculation was based on colour change. All OD samples had high vitamin content (24.6 mg/100 g fresh material compared to 138-154 mg/100 g osmodehydrated material; PEF led to 93% (of the initial vitamin retention; blanched samples showed the lowest retention (86.9% of the initial (criteria for SL calculation. OD and combined PEF-OD treatment increased the shelf life of frozen kiwifruit (up to 3 times; based on sensorial criteria. The developed kinetic models for colour change, vitamin loss, and sensory quality deterioration were validated at dynamic temperature conditions. PEF pretreated OD (at significantly shorter time, 30 min compared to 60 min kiwifruits retained optimum quality and sensory characteristics. PEF and OD could be used as a preprocessing

  8. β-Adrenoceptor activation depresses brain inflammation and is neuroprotective in lipopolysaccharide-induced sensitization to oxygen-glucose deprivation in organotypic hippocampal slices

    Directory of Open Access Journals (Sweden)

    Cilio Corrado

    2010-12-01

    Full Text Available Abstract Background Inflammation acting in synergy with brain ischemia aggravates perinatal ischemic brain damage. The sensitizing effect of pro-inflammatory exposure prior to hypoxia is dependent on signaling by TNF-α through TNF receptor (TNFR 1. Adrenoceptor (AR activation is known to modulate the immune response and synaptic transmission. The possible protective effect of α˜ and β˜AR activation against neuronal damage caused by tissue ischemia and inflammation, acting in concert, was evaluated in murine hippocampal organotypic slices treated with lipopolysaccharide (LPS and subsequently subjected to oxygen-glucose deprivation (OGD. Method Hippocampal slices from mice were obtained at P6, and were grown in vitro for 9 days on nitrocellulose membranes. Slices were treated with β1(dobutamine-, β2(terbutaline-, α1(phenylephrine- and α2(clonidine-AR agonists (5 and 50 μM, respectively during LPS (1 μg/mL, 24 h -exposure followed by exposure to OGD (15 min in a hypoxic chamber. Cell death in the slice CA1 region was assessed by propidium iodide staining of dead cells. Results Exposure to LPS + OGD caused extensive cell death from 4 up to 48 h after reoxygenation. Co-incubation with β1-agonist (50 μM during LPS exposure before OGD conferred complete protection from cell death (P -/- and TNFR2-/- slices exposed to LPS followed by OGD. Conclusions Our data demonstrate that activation of both β1- and β2-receptors is neuroprotective and may offer mechanistic insights valuable for development of neuro-protective strategies in neonates.

  9. Bilevel thresholding of sliced image of sludge floc.

    Science.gov (United States)

    Chu, C P; Lee, D J

    2004-02-15

    This work examined the feasibility of employing various thresholding algorithms to determining the optimal bilevel thresholding value for estimating the geometric parameters of sludge flocs from the microtome sliced images and from the confocal laser scanning microscope images. Morphological information extracted from images depends on the bilevel thresholding value. According to the evaluation on the luminescence-inverted images and fractal curves (quadric Koch curve and Sierpinski carpet), Otsu's method yields more stable performance than other histogram-based algorithms and is chosen to obtain the porosity. The maximum convex perimeter method, however, can probe the shapes and spatial distribution of the pores among the biomass granules in real sludge flocs. A combined algorithm is recommended for probing the sludge floc structure.

  10. Maximal slicing of D-dimensional spherically symmetric vacuum spacetime

    International Nuclear Information System (INIS)

    Nakao, Ken-ichi; Abe, Hiroyuki; Yoshino, Hirotaka; Shibata, Masaru

    2009-01-01

    We study the foliation of a D-dimensional spherically symmetric black-hole spacetime with D≥5 by two kinds of one-parameter families of maximal hypersurfaces: a reflection-symmetric foliation with respect to the wormhole slot and a stationary foliation that has an infinitely long trumpetlike shape. As in the four-dimensional case, the foliations by the maximal hypersurfaces avoid the singularity irrespective of the dimensionality. This indicates that the maximal slicing condition will be useful for simulating higher-dimensional black-hole spacetimes in numerical relativity. For the case of D=5, we present analytic solutions of the intrinsic metric, the extrinsic curvature, the lapse function, and the shift vector for the foliation by the stationary maximal hypersurfaces. These data will be useful for checking five-dimensional numerical-relativity codes based on the moving puncture approach.

  11. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Salehhon, N; Hashim, S; Karim, M K A; Ang, W C; Musa, Y; Bahruddin, N A

    2017-01-01

    The increasing use of computed tomography (CT) in clinical practice marks the needs to understand the dose descriptor and dose profile. The purposes of the current study were to determine the CT dose index free-in-air (CTDI air ) in 128 slice CT scanner and to evaluate the single scan dose profile (SSDP). Thermoluminescent dosimeters (TLD-100) were used to measure the dose profile of the scanner. There were three sets of CT protocols where the tube potential (kV) setting was manipulated for each protocol while the rest of parameters were kept constant. These protocols were based from routine CT abdominal examinations for male adult abdomen. It was found that the increase of kV settings made the values of CTDI air increased as well. When the kV setting was changed from 80 kV to 120 kV and from 120 kV to 140 kV, the CTDI air values were increased as much as 147.9% and 53.9% respectively. The highest kV setting (140 kV) led to the highest CTDI air value (13.585 mGy). The p -value of less than 0.05 indicated that the results were statistically different. The SSDP showed that when the kV settings were varied, the peak sharpness and height of Gaussian function profiles were affected. The full width at half maximum (FWHM) of dose profiles for all protocols were coincided with the nominal beam width set for the measurements. The findings of the study revealed much information on the characterization and performance of 128 slice CT scanner. (paper)

  12. Ring artifacts removal from synchrotron CT image slices

    International Nuclear Information System (INIS)

    Wei Zhouping; Chapman, Dean; Wiebe, Sheldon

    2013-01-01

    Ring artifacts can occur in reconstructed images from x-ray Computerized Tomography (CT) as full or partial concentric rings superimposed on the scanned structures. Due to the data corruption by those ring artifacts in CT images, qualitative and quantitative analysis of these images are compromised. In this paper, we propose to correct the ring artifacts on the reconstructed synchrotron radiation (SR) CT image slices. The proposed correction procedure includes the following steps: (1). transform the reconstructed CT images into polar coordinates; (2) apply discrete two-dimensional (2D) wavelet transform to the polar image to decompose it into four image components: low pass band image component, as well as the components from horizontal, vertical and diagonal details bands; (3). apply 2D Fourier transform to the vertical details band image component only, since the ring artifacts become vertical lines in the polar coordinates; (4). apply Gaussian filtering in Fourier domain along the abscissa direction to suppress the vertical lines, since the information of the vertical lines in Fourier domain is completely condensed to that direction; (5). perform inverse Fourier transform to get the corrected vertical details band image component; (6). perform inverse wavelet transform to get the corrected polar image; (7). transform the corrected polar image back to Cartesian coordinates to get the CT image slice with reduced ring artifacts. This approach has been successfully used on CT data acquired from the Biomedical Imaging and Therapy (BMIT) beamline in Canadian Light Source (CLS), and the results show that the ring artifacts in original SR CT images have been effectively suppressed with all the structure information in the image preserved.

  13. Simultaneous multislice magnetic resonance fingerprinting (SMS-MRF) with direct-spiral slice-GRAPPA (ds-SG) reconstruction.

    Science.gov (United States)

    Ye, Huihui; Cauley, Stephen F; Gagoski, Borjan; Bilgic, Berkin; Ma, Dan; Jiang, Yun; Du, Yiping P; Griswold, Mark A; Wald, Lawrence L; Setsompop, Kawin

    2017-05-01

    To develop a reconstruction method to improve SMS-MRF, in which slice acceleration is used in conjunction with highly undersampled in-plane acceleration to speed up MRF acquisition. In this work two methods are employed to efficiently perform the simultaneous multislice magnetic resonance fingerprinting (SMS-MRF) data acquisition and the direct-spiral slice-GRAPPA (ds-SG) reconstruction. First, the lengthy training data acquisition is shortened by employing the through-time/through-k-space approach, in which similar k-space locations within and across spiral interleaves are grouped and are associated with a single set of kernel. Second, inversion recovery preparation (IR prepped), variable flip angle (FA), and repetition time (TR) are used for the acquisition of the training data, to increase signal variation and to improve the conditioning of the kernel fitting. The grouping of k-space locations enables a large reduction in the number of kernels required, and the IR-prepped training data with variable FA and TR provide improved ds-SG kernels and reconstruction performance. With direct-spiral slice-GRAPPA, tissue parameter maps comparable to that of conventional MRF were obtained at multiband (MB) = 3 acceleration using t-blipped SMS-MRF acquisition with 32-channel head coil at 3 Tesla (T). The proposed reconstruction scheme allows MB = 3 accelerated SMS-MRF imaging with high-quality T 1 , T 2 , and off-resonance maps, and can be used to significantly shorten MRF acquisition and aid in its adoption in neuro-scientific and clinical settings. Magn Reson Med 77:1966-1974, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  14. CASTOR {sup registered} HAW28M - a high heat load cask for transport and storage of vitrified high level waste containers

    Energy Technology Data Exchange (ETDEWEB)

    Vossnacke, A.; Klein, K.; Kuehne, B. [GNS Gesellschaft fuer Nuklear-Service mbH/GNB, Essen (Germany)

    2004-07-01

    Within the German return programme for vitrified high level waste (HLW) from reprocessing at COGEMA and BNFL up to now 39 casks loaded with 28 containers each were transported back to Germany and are stored in the Interim Storage Facility Gorleben (TBL-G) for up to 40 years. For transport and storage in all but one case the GNB casks CASTOR {sup registered} HAW 20/28 CG have been used. This cask type is designed to accommodate 20 or 28 HLW containers with a total thermal power of 45 kW maximum. In the near future, among the high level waste, which has to be returned to Germany, there will be an increasing number of containers of which the heat capacity and radioactive inventory will exceed the technical limits of the CASTOR {sup registered} HAW 20/28 CG. Therefore GNB has started the development of a new cask generation, named CASTOR {sup registered} HAW28M, meeting these future requirements. The CASTOR {sup registered} HAW28M is especially developed for the transport of vitrified residues from France and Great Britain to Germany. It complies with the international regulations for type B packages according to IAEA (International Atomic Energy Agency). It is thus guaranteed that even in case of any accident the cask body and the lid system remain functional and the safe confinement of the radioactive contents remains intact during transport. The CASTOR {sup registered} HAW28M fulfills not only the requirements for transport but also the acceptance criteria of interim storage: radiation shielding, heat dissipation, safe confinement under both normal and hypothetical accident conditions. Storage buildings such as the TBL-G simply support the safety functions of the cask. The challenge for the development results from higher requirements of the technical specification, particularly related to fuel which is reprocessed. As a consequence of the reprocessing of fuel with increased enrichment and burn up, higher heat capacity and sophisticated shielding measures have to be

  15. Three-dimensional assessment of brain tissue morphology

    Science.gov (United States)

    Müller, Bert; Germann, Marco; Jeanmonod, Daniel; Morel, Anne

    2006-08-01

    The microstructure of brain tissues becomes visible using different types of optical microscopy after the tissue sectioning. This preparation procedure introduces stress and strain in the anisotropic and inhomogeneous soft tissue slices, which are several 10 μm thick. Consequently, the three-dimensional dataset, generated out of the two-dimensional images with lateral submicrometer resolution, needs algorithms to correct the deformations, which can be significant for mellow tissue such as brain segments. The spatial resolution perpendicular to the slices is much worse with respect to the lateral sub-micrometer resolution. Therefore, we propose as complementary method the synchrotron-radiation-based micro computed tomography (SRμCT), which avoids any kind of preparation artifacts due to sectioning and histological processing and yields true micrometer resolution in the three orthogonal directions. The visualization of soft matter by the use of SRμCT, however, is often based on elaborate staining protocols, since the tissue exhibits (almost) the same x-ray absorption as the surrounding medium. Therefore, it is unexpected that human tissue from the pons and the medulla oblongata in phosphate buffer show several features such as the blood vessels and the inferior olivary nucleus without staining. The value of these tomograms lies especially in the precise non-rigid registration of the different sets of histological slices. Applications of this method to larger pieces of brain tissue, such as the human thalamus are planned in the context of stereotactic functional neurosurgery.

  16. Clinical application of multi-slice helical CT volumetric scanning in lumber spine

    International Nuclear Information System (INIS)

    Wang Ling; Ge Yinghui; Zhu Shaocheng; Zhang Ming; Cheng Tianming; Lei Zhidan; Lv Chuanjian; Sun Xiaoping; Wu Minghui; Guo Ying; Ma Qianli; Wen Zeying

    2008-01-01

    Objective: To evaluate the clinical application value of multi-slice helical CT volumetric (VH) scanning in lumber spine. Methods: One thousand of patients with back and leg pain who underwent CT examinations were selected as subjects. We simulated the traditional protocol of single-slice(SS) discrete scanning for L3/4, L4/5, and L5/S1 intervertebral discs. The VH scanning mode was performed with 120 kV, 210 mAs, pitch of 1.5 and coverage of 97.5 mm. The simulated SS scanning mode was performed with 120 kV, 240 mAs and coverage of 45.0 mm. The diagnostic outcomes and the radiation doses were compared between the two scanning modes. Two groups doctors observed ten terms, including the osseous spinal stenosis, narrowed intervertebral space and so on in two scanning modes respectively. Then consistency analysis of the data was carded out. Results: The VH scanning mode showed far more features than the SS mode. The detection rates of the VH mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, narrowed lateral recess, vertebral lesion, hypertrophy of L5 transverse process, abnormal direction of facet, facet degeneration, lumbar spondyloschisis, and paraspinal soft tissue were 11.8% (n=118), 38.5% (n=385), 9.3% (n=93), 46.8% (n=468), 31.4% (n=314), 5.7% (n= 57), 25.4% (n=254), 49.7% (n=497), 9.9% (n=99), and 0.6% (n=6) respectively, while the detection rates of the SS mode in ten terms were 5.6% (n=56), 0, 0.6% (n=6), 27.9% (n=279), 22.4% (n=224), 1.2% (n=12), 16.7% (n=167), 37.2% (n=372), 0.5% (n=5), and 0.2% (n=2) respectively. The difference between the two groups had statistically significance (average P 0.05). The detection rates of the VH mode were higher than the SS mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, lumbar spondyloschisis, being 6.2% (n=62), 38.5% (n=385), 8.7% (n=87), and 9.4% (n=94), respectively. In addition, VH mode only partially showed the articular

  17. Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images

    International Nuclear Information System (INIS)

    Jeong, Ho Gul; Kim, Kee Deog; Hu, Kyung Seok; Lee, Jae Bum; Park, Hyok; Han, Seung Ho; Choi, Seong Ho; Kim, Chong Kwan; Park, Chang Seo

    2006-01-01

    To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed: 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analysed by Mann-Whitney test. There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement

  18. A rapid and simple method for cryopreservation of human liver slices

    NARCIS (Netherlands)

    de Kanter, R; Olinga, Peter; Hof, I.H; de Jager, M.H; Verwillegen, W.A; Slooff, M.JH; Meijer, D.K F; Groothuis, Geny; Koster, H

    1. Precision-cut liver slices represent a suitable and convenient in vitro preparation for studying metabolism and toxicity mechanisms of drugs and toxic chemicals. Particularly in the case of human liver slices, cryopreservation would enable more efficient utilization of this scarce and irregularly

  19. HUMAN LIVER SLICES EXPRESS THE SAME LIDOCAINE BIOTRANSFORMATION RATE AS ISOLATED HUMAN HEPATOCYTES

    NARCIS (Netherlands)

    OLINGA, P; MEIJER, DKF; SLOOFF, MJH; GROOTHUIS, GMM; Merema, M.T.

    1993-01-01

    In order to investigate whether liver slices are a valuable tool for the assessment of drug metabolism in human liver, we compared the phase I metabolism of lidocaine in human liver slices and hepatocytes prepared from three human livers. Lidocaine is mainly metabolised to monoethylglycinexylidide

  20. Automatic slice identification in 3D medical images with a ConvNet regressor

    NARCIS (Netherlands)

    de Vos, Bob D.; Viergever, Max A.; de Jong, Pim A.; Išgum, Ivana

    2016-01-01

    Identification of anatomical regions of interest is a prerequisite in many medical image analysis tasks. We propose a method that automatically identifies a slice of interest (SOI) in 3D images with a convolutional neural network (ConvNet) regressor. In 150 chest CT scans two reference slices were

  1. Rat brain sagittal organotypic slice cultures as an ex vivo dopamine cell loss system.

    Science.gov (United States)

    McCaughey-Chapman, Amy; Connor, Bronwen

    2017-02-01

    Organotypic brain slice cultures are a useful tool to study neurological function as they provide a more complex, 3-dimensional system than standard 2-dimensional in vitro cell cultures. Building on a previously developed mouse brain slice culture protocol, we have developed a rat sagittal brain slice culture system as an ex vivo model of dopamine cell loss. We show that rat brain organotypic slice cultures remain viable for up to 6 weeks in culture. Using Fluoro-Gold axonal tracing, we demonstrate that the slice 3-dimensional cytoarchitecture is maintained over a 4 week culturing period, with particular focus on the nigrostriatal pathway. Treatment of the cultures with 6-hydroxydopamine and desipramine induces a progressive loss of Fluoro-Gold-positive nigral cells with a sustained loss of tyrosine hydroxylase-positive nigral cells. This recapitulates the pattern of dopaminergic degeneration observed in the rat partial 6-hydroxydopamine lesion model and, most importantly, the progressive pathology of Parkinson's disease. Our slice culture platform provides an advance over other systems, as we demonstrate for the first time 3-dimensional cytoarchitecture maintenance of rat nigrostriatal sagittal slices for up to 6 weeks. Our ex vivo organotypic slice culture system provides a long term cellular platform to model Parkinson's disease, allowing for the elucidation of mechanisms involved in dopaminergic neuron degeneration and the capability to study cellular integration and plasticity ex vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Biocompatibility of silicon-based arrays of electrodes coupled to organotypic hippocampal brain slice cultures

    DEFF Research Database (Denmark)

    Kristensen, Bjarne Winther; Noraberg, J; Thiébaud, P

    2001-01-01

    by Nissl staining, Timm sulphide silver-staining, microtubule-associated protein 2 (MAP2) and glial fibrillary acidic protein (GFAP) immunostaining, the slice cultures grown on chips did not differ from conventionally grown slice cultures. Neither were there any signs of astrogliosis or neurodegeneration...

  3. Optical microwave filter based on spectral slicing by use of arrayed waveguide gratings.

    Science.gov (United States)

    Pastor, Daniel; Ortega, Beatriz; Capmany, José; Sales, Salvador; Martinez, Alfonso; Muñoz, Pascual

    2003-10-01

    We have experimentally demonstrated a new optical signal processor based on the use of arrayed waveguide gratings. The structure exploits the concept of spectral slicing combined with the use of an optical dispersive medium. The approach presents increased flexibility from previous slicing-based structures in terms of tunability, reconfiguration, and apodization of the samples or coefficients of the transversal optical filter.

  4. The visibility of mandibular canal on orthoradial and oblique CBCT slices at molar implant sites

    International Nuclear Information System (INIS)

    Alkhader, Mustafa; Jarab, Fadi; Shaweesh, Ashraf; Hudieb, Malik

    2016-01-01

    The aim of the present study was to compare visibility of the mandibular canal on cone beam computed tomography (CBCT)-based orthoradial and oblique slices at molar implant sites. CBCT images for 132 mandibular molar implant sites were selected for the study. After generating orthoradial and oblique slices, two observers evaluated the visibility of the mandibular canal using three-point scoring scale (1-3, good to excellent). Wilcoxon signed-rank test compared the visibility scores of the two slices. Both orthoradial and oblique slices obtained from CBCT had only very good to excellent mandibular canal visibility scores. At 114 mandibular molar implant sites, the visibility score was equal on both orthoradial and oblique slices. Although the visibility score was higher on orthoradial slices for 12 implant sites, the visibility score was higher for six implant sites on oblique slices and the difference was not significant. Therefore, the visibility of the mandibular canal was excellent and comparable on most of orthoradial and oblique slices obtained from CBCT images

  5. Photon Entanglement Through Brain Tissue.

    Science.gov (United States)

    Shi, Lingyan; Galvez, Enrique J; Alfano, Robert R

    2016-12-20

    Photon entanglement, the cornerstone of quantum correlations, provides a level of coherence that is not present in classical correlations. Harnessing it by study of its passage through organic matter may offer new possibilities for medical diagnosis technique. In this work, we study the preservation of photon entanglement in polarization, created by spontaneous parametric down-conversion, after one entangled photon propagates through multiphoton-scattering brain tissue slices with different thickness. The Tangle-Entropy (TS) plots show the strong preservation of entanglement of photons propagating in brain tissue. By spatially filtering the ballistic scattering of an entangled photon, we find that its polarization entanglement is preserved and non-locally correlated with its twin in the TS plots. The degree of entanglement correlates better with structure and water content than with sample thickness.

  6. Modeling and Realization of a Bearingless Flux-Switching Slice Motor

    Directory of Open Access Journals (Sweden)

    Wolfgang Gruber

    2017-03-01

    Full Text Available This work introduces a novel bearingless slice motor design: the bearingless flux-switching slice motor. In contrast to state-of-the-art bearingless slice motors, the rotor in this new design does not include any permanent rotor magnets. This offers advantages for disposable devices, such as those used in the medical industry, and extends the range of bearingless slice motors toward high-temperature applications. In this study, our focus is on the analytical modeling of the suspension force torque generation of a single coil and the bearingless motor. We assessed motor performance in relation to motor topology by applying performance factors. A prototype motor was optimized, designed, and manufactured. We also presented the state-of-the-art nonlinear feedback control scheme used. The motor was operated, and both static and dynamic measurements were taken on a test bench, thus successfully demonstrating the functionality and applicability of the novel bearingless slice motor concept.

  7. Slice image pretreatment for cone-beam computed tomography based on adaptive filter

    International Nuclear Information System (INIS)

    Huang Kuidong; Zhang Dinghua; Jin Yanfang

    2009-01-01

    According to the noise properties and the serial slice image characteristics in Cone-Beam Computed Tomography (CBCT) system, a slice image pretreatment for CBCT based on adaptive filter was proposed. The judging criterion for the noise is established firstly. All pixels are classified into two classes: adaptive center weighted modified trimmed mean (ACWMTM) filter is used for the pixels corrupted by Gauss noise and adaptive median (AM) filter is used for the pixels corrupted by impulse noise. In ACWMTM filtering algorithm, the estimated Gauss noise standard deviation in the current slice image with offset window is replaced by the estimated standard deviation in the adjacent slice image to the current with the corresponding window, so the filtering accuracy of the serial images is improved. The pretreatment experiment on CBCT slice images of wax model of hollow turbine blade shows that the method makes a good performance both on eliminating noises and on protecting details. (authors)

  8. Slice simulation from a model of the parenchymous vascularization to evaluate texture features: work in progress.

    Science.gov (United States)

    Rolland, Y; Bézy-Wendling, J; Duvauferrier, R; Coatrieux, J L

    1999-03-01

    To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Parameters of statistical methods were measured on 16128x128 regions of interest, and mean values and standard deviation were calculated. For each parameter, the performances (discrimination power and stability) were evaluated. Among 11 calculated statistical parameters, three (homogeneity, entropy, mean of gradients) were found to have a good discriminating power to differentiate normal perfusion from hypervascularization, but only the gradient mean was found to have a good stability with respect to the thickness. Five parameters (run percentage, run length distribution, long run emphasis, contrast, and gray level distribution) were found to have intermediate results. In the remaining three, curtosis and correlation was found to have little discrimination power, skewness none. This 3D vascular model, which allows the generation of various examples of vascular textures, is a powerful tool to assess the performance of texture analysis methods. This improves our knowledge of the methods and should contribute to their a priori choice when designing clinical studies.

  9. Biosynthesis of lutropin in ovine pituitary slices: incorporation of [35S]sulfate in carbohydrate units

    International Nuclear Information System (INIS)

    Anumula, K.R.; Bahl, O.P.

    1983-01-01

    Sulfate incorporation into carbohydrate of lutropin (LH) has been studied in sheep pituitary slices using H 2 ( 35 )SO 4 . Labeled ovine LH was purified to homogeneity by Sephadex G-100 and carboxymethyl-Sephadex chromatography from both the incubation medium and tissue extract. Autoradiography of the gel showed only two protein bands which comigrated with the alpha and beta subunits of ovine LH in both the purified ovine LH and the immunoprecipitate obtained with LH-specific rabbit antiserum. Furthermore, [ 35 S]sulfate was also incorporated into several other proteins in addition to LH. The location of 35 SO/sub 2-(4)/ in the oligosaccharides of ovine LH was evidenced by its presence in the glycopeptides obtained by exhaustive Pronase digestion. The location and the point of attachment of sulfate in the carbohydrate unit were established by the isolation of 4-O-[ 35 S]sulfo-N-acetylhexosaminyl-glycerols and 4-O-[ 35 S] sulfo-N-acetylglucosaminitol from the Smith degradation products and by the release of 35 SO/sub 2-(4)/ by chondro-4-sulfatase. Thus, the present line of experimentation indicates the presence of sulfate on both the terminal N-acetylglucosamine and N-acetylgalactosamine in the oligosaccharide chains of the labeled ovine LH

  10. The role of multi-slice CT in preoperative staging of colonic tumors

    International Nuclear Information System (INIS)

    Zhang Miao; Chen Kemin; Zhao Zehua; Ling Huawei

    2005-01-01

    Objective: To determine the accuracy of multi-slice CT pneumocolon in the staging of colonic carcinomas. Methods: Thirty-six patients, who were strongly suspected to have colonic disorders, underwent CT pneumocolon before and after intravenous injection of iodinated contrast agent. CTVE, MPR, SSD, and Raysum images were then obtained by using 4 different softwares in workstation (ADW3.1). 33 positive cases were staged preoperatively according to TNM standard. All cases were proved by surgical or colonoscopic histology. Sensitivity and accuracy of MSCT were determined for the detection of cancers, lymph nodes, and metastases. Results: MSCT pneumocolon examinations demonstrated 32 lesions, missing one case. Sensitivity and positive accuracy value for T staging were 96.97% (32/33) and 87.88% (29/33), respectively; Sensitivity and positive accuracy value for lymph node involvement were 73.91% (17/23) and 69.57% (16/23), respectively. The density of metastatic lymph node was higher than that of normal one. Five cases in M stage were all diagnosed correctly. Conclusion: MSCT pneumocolon is a better method of depicting the colorectal carcinoma. It allows for accurate staging of the colorectal carcinoma, especially detecting the invasion of adjacent tissues and distant metastasis. However the value for early T staging in colorectal carcinoma and minute metastasis of lymph nodes is limited. It is helpful to combine all the findings of lymph nodes, including the size, density, and location, to make a correct diagnosis. (authors)

  11. Generation of live offspring from vitrified embryos with synthetic polymers SuperCool X-1000 and SuperCool Z-1000.

    Science.gov (United States)

    Marco-Jimenez, F; Jimenez-Trigos, E; Lavara, R; Vicente, J S

    2014-01-01

    Ice growth and recrystallisation are considered important factors in determining vitrification outcomes. Synthetic polymers inhibit ice formation during cooling or warming of the vitrification process. The aim of this study was to assess the effect of adding commercially available synthetic polymers SuperCool X-1000 and SuperCool Z-1000 to vitrification media on in vivo development competence of rabbit embryos. Four hundred and thirty morphologically normal embryos recovered at 72 h of gestation were used. The vitrification media contained 20% dimethyl sulphoxide and 20% ethylene glycol, either alone or in combination with 1% of SuperCool X-1000 and 1% SuperCool. Our results show that embryos can be successfully vitrified using SuperCool X-1000 and SuperCool Z-1000 and when embryos are transferred, live offspring can be successfully produced. In conclusion, our results demonstrated that we succeeded for the first time in obtaining live offspring after vitrification of embryos using SuperCool X-1000 and SuperCool Z-1000 polymers.

  12. Culture time of vitrified/warmed zygotes before microinjection affects the production efficiency of CRISPR-Cas9-mediated knock-in mice.

    Science.gov (United States)

    Nakagawa, Yoshiko; Sakuma, Tetsushi; Nishimichi, Norihisa; Yokosaki, Yasuyuki; Takeo, Toru; Nakagata, Naomi; Yamamoto, Takashi

    2017-05-15

    Robust reproductive engineering techniques are required for the efficient and rapid production of genetically modified mice. We have reported the efficient production of genome-edited mice using reproductive engineering techniques, such as ultra-superovulation, in vitro fertilization (IVF) and vitrification/warming of zygotes. We usually use vitrified/warmed fertilized oocytes created by IVF for microinjection because of work efficiency and flexible scheduling. Here, we investigated whether the culture time of zygotes before microinjection influences the efficiency of producing knock-in mice. Knock-in mice were generated using clustered regularly interspaced short palindromic repeats (CRISPR)-CRISPR-associated protein 9 (Cas9) system and single-stranded oligodeoxynucleotide (ssODN) or PITCh (Precise Integration into Target Chromosome) system, a method of integrating a donor vector assisted by microhomology-mediated end-joining. The cryopreserved fertilized oocytes were warmed, cultured for several hours and microinjected at different timings. Microinjection was performed with Cas9 protein, guide RNA(s), and an ssODN or PITCh donor plasmid for the ssODN knock-in and the PITCh knock-in, respectively. Different production efficiencies of knock-in mice were observed by changing the timing of microinjection. Our study provides useful information for the CRISPR-Cas9-based generation of knock-in mice. © 2017. Published by The Company of Biologists Ltd.

  13. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  14. Endogenous 24S-hydroxycholesterol modulates NMDAR-mediated function in hippocampal slices.

    Science.gov (United States)

    Sun, Min-Yu; Izumi, Yukitoshi; Benz, Ann; Zorumski, Charles F; Mennerick, Steven

    2016-03-01

    N-methyl-D-aspartate receptors (NMDARs), a major subtype of glutamate receptors mediating excitatory transmission throughout the central nervous system (CNS), play critical roles in governing brain function and cognition. Because NMDAR dysfunction contributes to the etiology of neurological and psychiatric disorders including stroke and schizophrenia, NMDAR modulators are potential drug candidates. Our group recently demonstrated that the major brain cholesterol metabolite, 24S-hydroxycholesterol (24S-HC), positively modulates NMDARs when exogenously administered. Here, we studied whether endogenous 24S-HC regulates NMDAR activity in hippocampal slices. In CYP46A1(-/-) (knockout; KO) slices where endogenous 24S-HC is greatly reduced, NMDAR tone, measured as NMDAR-to-α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor (AMPAR) excitatory postsynaptic current (EPSC) ratio, was reduced. This difference translated into more NMDAR-driven spiking in wild-type (WT) slices compared with KO slices. Application of SGE-301, a 24S-HC analog, had comparable potentiating effects on NMDAR EPSCs in both WT and KO slices, suggesting that endogenous 24S-HC does not saturate its NMDAR modulatory site in ex vivo slices. KO slices did not differ from WT slices in either spontaneous neurotransmission or in neuronal intrinsic excitability, and exhibited LTP indistinguishable from WT slices. However, KO slices exhibited higher resistance to persistent NMDAR-dependent depression of synaptic transmission induced by oxygen-glucose deprivation (OGD), an effect restored by SGE-301. Together, our results suggest that loss of positive NMDAR tone does not elicit compensatory changes in excitability or transmission, but it protects transmission against NMDAR-mediated dysfunction. We expect that manipulating this endogenous NMDAR modulator may offer new treatment strategies for neuropsychiatric dysfunction. Copyright © 2016 the American Physiological Society.

  15. Effects of normobaric versus hyperbaric oxygen on cell injury induced by oxygen and glucose deprivation in acute brain slices

    Directory of Open Access Journals (Sweden)

    Laurent Chazalviel

    2016-01-01

    Full Text Available Normobaric oxygen (NBO and hyperbaric oxygen (HBO are emerging as a possible co-treatment of acute ischemic stroke. Both have been shown to reduce infarct volume, to improve neurologic outcome, to promote endogenous tissue plasminogen activator-induced thrombolysis and cerebral blood flow, and to improve tissue oxygenation through oxygen diffusion in the ischemic areas, thereby questioning the interest of HBO compared to NBO. In the present study, in order to investigate and compare the oxygen diffusion effects of NBO and HBO on acute ischemic stroke independently of their effects at the vascular level, we used acute brain slices exposed to oxygen and glucose deprivation, an ex vivo model of brain ischemia that allows investigating the acute effects of NBO (partial pressure of oxygen (pO 2 = 1 atmospheres absolute (ATA = 0.1 MPa and HBO (pO 2 = 2.5 ATA = 0.25 MPa through tissue oxygenation on ischemia-induced cell injury as measured by the release of lactate dehydrogenase. We found that HBO, but not NBO, reduced oxygen and glucose deprivation-induced cell injury, indicating that passive tissue oxygenation (i.e. without vascular support of the brain parenchyma requires oxygen partial pressure higher than 1 ATA.

  16. Investigation of lung nodule detectability in low-dose 320-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, J. D.; Paul, N. S.; Siewerdsen, J. H. [Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Imaging, Toronto General Hospital, Toronto, Ontario M5G 2C6 (Canada); Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Ontario Cancer Institute, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2009-05-15

    Low-dose imaging protocols in chest CT are important in the screening and surveillance of suspicious and indeterminate lung nodules. Techniques that maintain nodule detectability yet permit dose reduction, particularly for large body habitus, were investigated. The objective of this study was to determine the extent to which radiation dose can be minimized while maintaining diagnostic performance through knowledgeable selection of reconstruction techniques. A 320-slice volumetric CT scanner (Aquilion ONE, Toshiba Medical Systems) was used to scan an anthropomorphic phantom at doses ranging from {approx}0.1 mGy up to that typical of low-dose CT (LDCT, {approx}5 mGy) and diagnostic CT ({approx}10 mGy). Radiation dose was measured via Farmer chamber and MOSFET dosimetry. The phantom presented simulated nodules of varying size and contrast within a heterogeneous background, and chest thickness was varied through addition of tissue-equivalent bolus about the chest. Detectability of a small solid lung nodule (3.2 mm diameter, -37 HU, typically the smallest nodule of clinical significance in screening and surveillance) was evaluated as a function of dose, patient size, reconstruction filter, and slice thickness by means of nine-alternative forced-choice (9AFC) observer tests to quantify nodule detectability. For a given reconstruction filter, nodule detectability decreased sharply below a threshold dose level due to increased image noise, especially for large body size. However, nodule detectability could be maintained at lower doses through knowledgeable selection of (smoother) reconstruction filters. For large body habitus, optimal filter selection reduced the dose required for nodule detection by up to a factor of {approx}3 (from {approx}3.3 mGy for sharp filters to {approx}1.0 mGy for the optimal filter). The results indicate that radiation dose can be reduced below the current low-dose (5 mGy) and ultralow-dose (1 mGy) levels with knowledgeable selection of

  17. Vitrification of human ovarian tissue: effect of different solutions and procedures.

    Science.gov (United States)

    Amorim, Christiani Andrade; David, Anu; Van Langendonckt, Anne; Dolmans, Marie-Madeleine; Donnez, Jacques

    2011-03-01

    To test the effect of different vitrification solutions and procedures on the morphology of human preantral follicles. Pilot study. Gynecology research unit in a university hospital. Ovarian biopsies were obtained from nine women aged 22-35 years. Ovarian tissue fragments were subjected to [1] different vitrification solutions to test their toxicity or [2] different vitrification methods using plastic straws, medium droplets, or solid-surface vitrification before in vitro culture. Number of morphologically normal follicles after toxicity testing or vitrification with the different treatments determined by histologic analysis. In the toxicity tests, only VS3 showed similar results to fresh tissue before and after in vitro culture (fresh controls 1 and 2). In addition, this was the only solution able to completely vitrify. In all vitrification procedures, the percentage of normal follicles was lower than in controls. However, of the three protocols, the droplet method yielded a significantly higher proportion of normal follicles. Our experiments showed VS3 to have no deleterious effect on follicular morphology and to be able to completely vitrify, although vitrification procedures were found to affect human follicles. Nevertheless, the droplet method resulted in a higher percentage of morphologically normal follicles. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  18. Slice of the LHC prototype beam tubes in dipole magnet

    CERN Multimedia

    1995-01-01

    A slice of the LHC accelerator prototype beam tubes surrounded by magnets. The LHC will accelerate two proton beams in opposite directions. The high bending and accelerating fields needed can only be reached using superconductors. At very low temperatures superconductors have no electrical resistance and therefore no power loss. The LHC will be the largest superconducting installation ever built, a unique challenge for CERN and its industrial partners. About dipole magnets: There will be 1232 dipole magnets in the LHC, used to guide the particles around the 27 km ring. Dipole magnets must have an extremely uniform field, which means the current flowing in the coils has to be very precisely controlled. Nowhere before has such precision been achieved at such high currents. The temperature is measured to five thousandths of a degree, the current to one part in a million. The current creating the magnetic field will pass through superconducting wires at up to 12 500 amps, about 30 000 times the current flowing ...

  19. Liver Effects of Clinical Drugs Differentiated in Human Liver Slices

    Directory of Open Access Journals (Sweden)

    Alison E. M. Vickers

    2017-03-01

    Full Text Available Drugs with clinical adverse effects are compared in an ex vivo 3-dimensional multi-cellular human liver slice model. Functional markers of oxidative stress and mitochondrial function, glutathione GSH and ATP levels, were affected by acetaminophen (APAP, 1 mM, diclofenac (DCF, 1 mM and etomoxir (ETM, 100 μM. Drugs targeting mitochondria more than GSH were dantrolene (DTL, 10 μM and cyclosporin A (CSA, 10 μM, while GSH was affected more than ATP by methimazole (MMI, 500 μM, terbinafine (TBF, 100 μM, and carbamazepine (CBZ 100 μM. Oxidative stress genes were affected by TBF (18%, CBZ, APAP, and ETM (12%–11%, and mitochondrial genes were altered by CBZ, APAP, MMI, and ETM (8%–6%. Apoptosis genes were affected by DCF (14%, while apoptosis plus necrosis were altered by APAP and ETM (15%. Activation of oxidative stress, mitochondrial energy, heat shock, ER stress, apoptosis, necrosis, DNA damage, immune and inflammation genes ranked CSA (75%, ETM (66%, DCF, TBF, MMI (61%–60%, APAP, CBZ (57%–56%, and DTL (48%. Gene changes in fatty acid metabolism, cholestasis, immune and inflammation were affected by DTL (51%, CBZ and ETM (44%–43%, APAP and DCF (40%–38%, MMI, TBF and CSA (37%–35%. This model advances multiple dosing in a human ex vivo model, plus functional markers and gene profile markers of drug induced human liver side-effects.

  20. Electrical coupling between hippocampal astrocytes in rat brain slices.

    Science.gov (United States)

    Meme, William; Vandecasteele, Marie; Giaume, Christian; Venance, Laurent

    2009-04-01

    Gap junctions in astrocytes play a crucial role in intercellular communication by supporting both biochemical and electrical coupling between adjacent cells. Despite the critical role of electrical coupling in the network organization of these glial cells, the electrophysiological properties of gap junctions have been characterized in cultures while no direct evidence has been sought in situ. In the present study, gap-junctional currents were investigated using simultaneous dual whole-cell patch-clamp recordings between astrocytes from rat hippocampal slices. Bidirectional electrotonic coupling was observed in 82% of the cell pairs with an average coupling coefficient of 5.1%. Double patch-clamp analysis indicated that junctional currents were independent of the transjunctional voltage over a range from -100 to +110 mV. Interestingly, astrocytic electrical coupling displayed weak low-pass filtering properties compared to neuronal electrical synapses. Finally, during uncoupling processes triggered by either the gap-junction inhibitor carbenoxolone or endothelin-1, an increase in the input resistance in the injected cell paralleled the decrease in the coupling coefficient. Altogether, these results demonstrate that hippocampal astrocytes are electrically coupled through gap-junction channels characterized by properties that are distinct from those of electrical synapses between neurons. In addition, gap-junctional communication is efficiently regulated by endogenous compounds. This is taken to represent a mode of communication that may have important implications for the functional role of astrocyte networks in situ.

  1. MSE spectrograph optical design: a novel pupil slicing technique

    Science.gov (United States)

    Spanò, P.

    2014-07-01

    The Maunakea Spectroscopic Explorer shall be mainly devoted to perform deep, wide-field, spectroscopic surveys at spectral resolutions from ~2000 to ~20000, at visible and near-infrared wavelengths. Simultaneous spectral coverage at low resolution is required, while at high resolution only selected windows can be covered. Moreover, very high multiplexing (3200 objects) must be obtained at low resolution. At higher resolutions a decreased number of objects (~800) can be observed. To meet such high demanding requirements, a fiber-fed multi-object spectrograph concept has been designed by pupil-slicing the collimated beam, followed by multiple dispersive and camera optics. Different resolution modes are obtained by introducing anamorphic lenslets in front of the fiber arrays. The spectrograph is able to switch between three resolution modes (2000, 6500, 20000) by removing the anamorphic lenses and exchanging gratings. Camera lenses are fixed in place to increase stability. To enhance throughput, VPH first-order gratings has been preferred over echelle gratings. Moreover, throughput is kept high over all wavelength ranges by splitting light into more arms by dichroic beamsplitters and optimizing efficiency for each channel by proper selection of glass materials, coatings, and grating parameters.

  2. N* resonances from KΛ amplitudes in sliced bins in energy

    Energy Technology Data Exchange (ETDEWEB)

    Anisovich, A.V.; Nikonov, V.A.; Sarantsev, A.V. [Helmholtz-Institute fuer Strahlen- und Kernphysik, Universitaet Bonn (Germany); Particle and Nuclear Physics Institute, Gatchina (Russian Federation); Burkert, V. [Thomas Jefferson Laboratory, Newport News, VA (United States); Hadzimehmedovic, M.; Omerovic, R.; Stahov, J. [University of Tuzla, Faculty of Natural Sciences and Mathematics, Tuzla (Bosnia and Herzegovina); Ireland, D.G. [University of Glasgow, SUPA, School of Physics and Astronomy, Glasgow (United Kingdom); Klempt, E. [Helmholtz-Institute fuer Strahlen- und Kernphysik, Universitaet Bonn (Germany); Thomas Jefferson Laboratory, Newport News, VA (United States); Svarc, A. [Rudjer Boskovic Institute, Zagreb (Croatia); Thoma, U. [Helmholtz-Institute fuer Strahlen- und Kernphysik, Universitaet Bonn (Germany)

    2017-12-15

    The two reactions γp → K{sup +}Λ and π{sup -}p → K{sup 0}Λ are analyzed to determine the leading photoproduction multipoles and the pion-induced partial wave amplitudes in slices of the invariant mass. The multipoles and the partial-wave amplitudes are simultaneously fitted in a multichannel Laurent+Pietarinen model (L+P model), which determines the poles in the complex energy plane on the second Riemann sheet close to the physical axes. The results from the L+P fit are compared with the results of an energy-dependent fit based on the Bonn-Gatchina (BnGa) approach. The study confirms the existence of several poles due to nucleon resonances in the region at about 1.9 GeV with quantum numbers J{sup P} = 1/2{sup +}, 3/2{sup +}, 1/2{sup -}, 3/2{sup -}, 5/2{sup -}. (orig.)

  3. Enhancement of DNA polymerase activity in potato tuber slices

    International Nuclear Information System (INIS)

    Watanabe, Akira; Imaseki, Hidemasa

    1977-01-01

    DNA polymerase was extracted from potato (Soleum tuberosum L.) tuber discs and the temporal correlation of its activity change to DNA synthesis in vivo was examined during aging of the discs. Most of the DNA polymerase was recovered as a bound form in the 18,000 x g precipitate. Reaction with the bound-form enzyme was dependent on the presence of four deoxynucleoside triphosphates, Mg 2+ , and a template. ''Activated'' DNA and heat-denatured DNA, but not native DNA, were utilized as templates. The polymerase activity was sensitive to SH reagents. Fresh discs, which do not synthesize DNA in vivo, contained a significant amount of DNA polymerase and its activity increased linearly with time until 48 hr after slicing and became four times that of fresh discs after 72 hr, whereas the activity of DNA synthesis in vivo increased with time and decreased after reaching a maximum at 30 hr. Cycloheximide inhibited the enhancement of polymerase activity. DNA polymerase from aged and fresh discs had identical requirements for deoxynucleotides and a template in their reactions, sensitivity to SH reagent, and affinity to thymidine triphosphate. (auth.)

  4. Color changes kinetics during deep fat frying of carrot slice

    Science.gov (United States)

    Salehi, Fakhreddin

    2018-05-01

    Heat and mass transfer phenomena take place during frying cause physicochemical changes, which affect the colour and surface of the fried products. The effect of frying temperature on the colour changes and heat transfer during deep fat frying of carrot has been investigated. The colour scale parameters redness (a*), yellowness (b*) and lightness (L*), and color change intensity (ΔE) were used to estimate colour changes during frying as a function of oil temperature. L* value of fried carrot decreased during frying. The redness of fried carrot decreased during the early stages of frying, while it increased afterwards (become more red). A first-order kinetic equation was used for each one of the three colour parameters, in which the rate constant is a function of oil temperatures. The results showed that oil temperature has a significant effect on the colour parameters. Different kinetic models were used to fit the experimental data and the results revealed that the quadratic model was the most suitable to describe the color change intensity (ΔE) (R > 0.96). Center temperature of carrot slice increased with increase in oil temperature and time during frying.

  5. Slicing-independent RISC activation requires the argonaute PAZ domain.

    Science.gov (United States)

    Gu, Shuo; Jin, Lan; Huang, Yong; Zhang, Feijie; Kay, Mark A

    2012-08-21

    Small RNAs regulate genetic networks through a ribonucleoprotein complex called the RNA-induced silencing complex (RISC), which, in mammals, contains at its center one of four Argonaute proteins (Ago1-Ago4). A key regulatory event in the RNA interference (RNAi) and microRNA (miRNA) pathways is Ago loading, wherein double-stranded small-RNA duplexes are incorporated into RISC (pre-RISC) and then become single-stranded (mature RISC), a process that is not well understood. The Agos contain an evolutionarily conserved PAZ (Piwi/Argonaute/Zwille) domain whose primary function is to bind the 3' end of small RNAs. We created multiple PAZ-domain-disrupted mutant Ago proteins and studied their biochemical properties and biological functionality in cells. We found that the PAZ domain is dispensable for Ago loading of slicing-competent RISC. In contrast, in the absence of slicer activity or slicer-substrate duplex RNAs, PAZ-disrupted Agos bound duplex small interfering RNAs, but were unable to unwind or eject the passenger strand and form functional RISC complexes. We have discovered that the highly conserved PAZ domain plays an important role in RISC activation, providing new mechanistic insights into how miRNAs regulate genes, as well as new insights for future design of miRNA- and RNAi-based therapeutics. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. A Novel Approach for Transmission of 56 Gbit/s NRZ Signal in Access Network Using Spectrum Slicing Technique

    DEFF Research Database (Denmark)

    Spolitis, S.; Vegas Olmos, Juan José; Bobrovs, V.

    2013-01-01

    We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time.......We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time....

  7. Culturing of PC12 Cells, Neuronal Cells, Astrocytes Cultures and Brain Slices in an Open Microfluidic System

    DEFF Research Database (Denmark)

    Al Atraktchi, Fatima Al-Zahraa; Bakmand, Tanya; Rømer Sørensen, Ane

    The brain is the center of the nervous system, where serious neurodegenerative diseases such as Parkinson’s, Alzheimer’s and Huntington’s are products of functional loss in the neural cells (1). Typical techniques used to investigate these diseases lack precise control of the cellular surroundings......, in addition to isolating the neural tissue from nutrient delivery and to creating unwanted gradients (2). This means that typical techniques used to investigate neurodegenerative diseases cannot mimic in vivo conditions, as closely as desired. We have developed a novel microfluidic system for culturing PC12...... cells, neuronal cells, astrocytes cultures and brain slices. The microfluidic system provides efficient nutrient delivery, waste removal, access to oxygen, fine control over the neurochemical environment and access to modern microscopy. Additionally, the setup consists of an in vitro culturing...

  8. Target recognition of ladar range images using slice image: comparison of four improved algorithms

    Science.gov (United States)

    Xia, Wenze; Han, Shaokun; Cao, Jingya; Wang, Liang; Zhai, Yu; Cheng, Yang

    2017-07-01

    Compared with traditional 3-D shape data, ladar range images possess properties of strong noise, shape degeneracy, and sparsity, which make feature extraction and representation difficult. The slice image is an effective feature descriptor to resolve this problem. We propose four improved algorithms on target recognition of ladar range images using slice image. In order to improve resolution invariance of the slice image, mean value detection instead of maximum value detection is applied in these four improved algorithms. In order to improve rotation invariance of the slice image, three new improved feature descriptors-which are feature slice image, slice-Zernike moments, and slice-Fourier moments-are applied to the last three improved algorithms, respectively. Backpropagation neural networks are used as feature classifiers in the last two improved algorithms. The performance of these four improved recognition systems is analyzed comprehensively in the aspects of the three invariances, recognition rate, and execution time. The final experiment results show that the improvements for these four algorithms reach the desired effect, the three invariances of feature descriptors are not directly related to the final recognition performance of recognition systems, and these four improved recognition systems have different performances under different conditions.

  9. Magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere

    Science.gov (United States)

    Nursalim, Rahmat; Widodo, Basuki; Imron, Chairul

    2017-10-01

    Magnetohydrodynamics (MHD) is important study in engineering and industrial fields. By study on MHD, we can reach the fluid flow characteristics that can be used to minimize its negative effect to an object. In decades, MHD has been widely studied in various geometry forms and fluid types. The sliced sphere is a geometry form that has not been investigated. In this paper we study magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere. Assumed that the fluid is incompressible, there is no magnetic field, there is no electrical voltage, the sliced sphere is fix and there is no barrier around the object. In this paper we focus on velocity profile at stagnation point (x = 0°). Mathematical model is governed by continuity and momentum equation. It is converted to non-dimensional, stream function, and similarity equation. Solution of the mathematical model is obtained by using Keller-Box numerical method. By giving various of slicing angle and various of magnetic parameter we get the simulation results. The simulation results show that increasing the slicing angle causes the velocity profile be steeper. Also, increasing the value of magnetic parameter causes the velocity profile be steeper. On the large slicing angle there is no significant effect of magnetic parameter to velocity profile, and on the high the value of magnetic parameter there is no significant effect of slicing angle to velocity profile.

  10. Lysosome stabilization in slices of rat liver when incubated with vitamin A excess

    International Nuclear Information System (INIS)

    Morre, D.M.; Morre, D.J.; Bowen, S.; Reutter, W.

    1986-01-01

    An organ culture of slices of livers from adult rats was used to study effect of vitamin A (all-trans retinol) on lysosome stability. Lysosomes were purified by centrifugation in Percoll gradients. Preparations were monitored by electron microscopy and evaluated by morphometry and assays of marker enzymes. Enrichments relative to homogenates and crude pellets were estimated from latent (triton X-100) acid p-nitrophenylphosphatase specific activities. Lysosomes prepared from unincubated slices were enriched 50-fold in latent acid phosphatase relative to homogenates. In contrast, lysosomes prepared from slices incubated for 30 min in PBS alone were enriched only 20-fold. When 25 μg/ml retinol was included in the incubation medium, enrichments of 40-fold were obtained. The integrity of the slices was monitored by electron microscopy and their viability was confirmed by a sustained uptake and incorporation of [ 3 H]leucine into protein (up to 2 h in culture). The loss of lysosomes from homogenates of slices incubated in the absence of retinol was accompanied by a loss of acid phosphatase from the lysosomal pellet to the supernatant during purification. Addition of retinol to slices just prior to homogenization was without effect. The results demonstrate a stabilizing influence of vitamin A on lysosomes during incubation of licer slices. The findings contrast earlier reports of retinol-induced lysosome fragility in other in vitro systems

  11. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  12. Adaptive SLICE method: an enhanced method to determine nonlinear dynamic respiratory system mechanics

    International Nuclear Information System (INIS)

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    The objective of this paper is to introduce and evaluate the adaptive SLICE method (ASM) for continuous determination of intratidal nonlinear dynamic compliance and resistance. The tidal volume is subdivided into a series of volume intervals called slices. For each slice, one compliance and one resistance are calculated by applying a least-squares-fit method. The volume window (width) covered by each slice is determined based on the confidence interval of the parameter estimation. The method was compared to the original SLICE method and evaluated using simulation and animal data. The ASM was also challenged with separate analysis of dynamic compliance during inspiration. If the signal-to-noise ratio (SNR) in the respiratory data decreased from +∞ to 10 dB, the relative errors of compliance increased from 0.1% to 22% for the ASM and from 0.2% to 227% for the SLICE method. Fewer differences were found in resistance. When the SNR was larger than 40 dB, the ASM delivered over 40 parameter estimates (42.2 ± 1.3). When analyzing the compliance during inspiration separately, the estimates calculated with the ASM were more stable. The adaptive determination of slice bounds results in consistent and reliable parameter values. Online analysis of nonlinear respiratory mechanics will profit from such an adaptive selection of interval size. (paper)

  13. Brain tissue stiffness is a sensitive marker for acidosis.

    Science.gov (United States)

    Holtzmann, Kathrin; Gautier, Hélène O B; Christ, Andreas F; Guck, Jochen; Káradóttir, Ragnhildur Thóra; Franze, Kristian

    2016-09-15

    Carbon dioxide overdose is frequently used to cull rodents for tissue harvesting. However, this treatment may lead to respiratory acidosis, which potentially could change the properties of the investigated tissue. Mechanical tissue properties often change in pathological conditions and may thus offer a sensitive generic readout for changes in biological tissues with clinical relevance. In this study, we performed force-indentation measurements with an atomic force microscope on acute cerebellar slices from adult rats to test if brain tissue undergoes changes following overexposure to CO2 compared to other methods of euthanasia. The pH significantly decreased in brain tissue of animals exposed to CO2. Concomitant with the drop in pH, cerebellar grey matter significantly stiffened. Tissue stiffening was reproduced by incubation of acute cerebellar slices in acidic medium. Tissue stiffness provides an early, generic indicator for pathophysiological changes in the CNS. Atomic force microscopy offers unprecedented high spatial resolution to detect such changes. Our results indicate that the stiffness particularly of grey matter strongly correlates with changes of the pH in the cerebellum. Furthermore, the method of tissue harvesting and preparation may not only change tissue stiffness but very likely also other physiologically relevant parameters, highlighting the importance of appropriate sample preparation. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Tissue engineering

    CERN Document Server

    Fisher, John P; Bronzino, Joseph D

    2007-01-01

    Increasingly viewed as the future of medicine, the field of tissue engineering is still in its infancy. As evidenced in both the scientific and popular press, there exists considerable excitement surrounding the strategy of regenerative medicine. To achieve its highest potential, a series of technological advances must be made. Putting the numerous breakthroughs made in this field into a broad context, Tissue Engineering disseminates current thinking on the development of engineered tissues. Divided into three sections, the book covers the fundamentals of tissue engineering, enabling technologies, and tissue engineering applications. It examines the properties of stem cells, primary cells, growth factors, and extracellular matrix as well as their impact on the development of tissue engineered devices. Contributions focus on those strategies typically incorporated into tissue engineered devices or utilized in their development, including scaffolds, nanocomposites, bioreactors, drug delivery systems, and gene t...

  15. Effect of dentin bonding agent diffusing through dentin slices on the reactive oxygen species production and apoptosis of pulpal cells

    Directory of Open Access Journals (Sweden)

    Bor-Shiunn Lee

    2015-04-01

    Conclusion: The three DBAs after diffusion through 0.2- or 0.5-mm dentin slice still exhibit cytotoxicity to dental pulp cells. However, the 0.5-mm dentin slice is found to be a better barrier than the 0.2-mm dentin slice to protect dental pulp cells from DBA-induced cytotoxicity.

  16. Excitatory and inhibitory pathways modulate kainate excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Casaccia-Bonnefil, P; Benedikz, Eirikur; Rai, R

    1993-01-01

    In organotypic hippocampal slice cultures, kainate (KA) specifically induces cell loss in the CA3 region while N-methyl-D-aspartate induces cell loss in the CA1 region. The sensitivity of slice cultures to KA toxicity appears only after 2 weeks in vitro which parallels the appearance of mossy...... fibers. KA toxicity is potentiated by co-application with the GABA-A antagonist, picrotoxin. These data suggest that the excitotoxicity of KA in slice cultures is modulated by both excitatory and inhibitory synapses....

  17. Software framework developed for the slice test of the ATLAS endcap muon trigger system

    CERN Document Server

    Komatsu, S; Ishida, Y; Tanaka, K; Hasuko, K; Kano, H; Matsumoto, Y; Yakamura, Y; Sakamoto, H; Ikeno, M; Nakayoshi, K; Sasaki, O; Yasu, Y; Hasegawa, Y; Totsuka, M; Tsuji, S; Maeno, T; Ichimiya, R; Kurashige, H

    2002-01-01

    A sliced system test of the ATLAS end cap muon level 1 trigger system has been done in 2001 and 2002 separately. We have developed an own software framework for property and run controls for the slice test in 2001. The system is described in C++ throughout. The multi-PC control system is accomplished using the CORBA system. We have then restructured the software system on top of the ATLAS online software framework, and used this one for the slice test in 2002. In this report we discuss two systems in detail with emphasizing the module property configuration and run control. (8 refs).

  18. Applicability of rat precision-cut lung slices in evaluating nanomaterial cytotoxicity, apoptosis, oxidative stress, and inflammation

    Energy Technology Data Exchange (ETDEWEB)

    Sauer, Ursula G. [Scientific Consultancy — Animal Welfare, Neubiberg (Germany); Vogel, Sandra [Experimental Toxicology and Ecology, BASF SE, Ludwigshafen (Germany); Product Stewardship Water Solutions, BASF SE, Ludwigshafen (Germany); Aumann, Alexandra; Hess, Annemarie; Kolle, Susanne N.; Ma-Hock, Lan [Experimental Toxicology and Ecology, BASF SE, Ludwigshafen (Germany); Wohlleben, Wendel [Experimental Toxicology and Ecology, BASF SE, Ludwigshafen (Germany); Material Physics, BASF SE, Ludwigshafen (Germany); Dammann, Martina; Strauss, Volker; Treumann, Silke; Gröters, Sibylle [Experimental Toxicology and Ecology, BASF SE, Ludwigshafen (Germany); Wiench, Karin [Product Safety, BASF SE, Ludwigshafen (Germany); Ravenzwaay, Bennard van [Experimental Toxicology and Ecology, BASF SE, Ludwigshafen (Germany); Landsiedel, Robert, E-mail: robert.landsiedel@basf.com [Experimental Toxicology and Ecology, BASF SE, Ludwigshafen (Germany)

    2014-04-01

    The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO{sub 2}, ZnO, CeO{sub 2}, SiO{sub 2}, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO{sub 2} NMs, CeO{sub 2} NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO{sub 2} NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO{sub 2} NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO{sub 2} only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization. - Highlights: • 16 OECD reference nanomaterials were tested in rat precision-cut lung slices. • Nanomaterial cytotoxicity, apoptose, oxidative stress, and inflammation were

  19. Electron slicing for the generation of tunable femtosecond soft x-ray pulses from a free electron laser and slice diagnostics

    Directory of Open Access Journals (Sweden)

    S. Di Mitri

    2013-04-01

    Full Text Available We present the experimental results of femtosecond slicing an ultrarelativistic, high brightness electron beam with a collimator. In contrast to some qualitative considerations reported in Phys. Rev. Lett. 92, 074801 (2004PRLTAO0031-900710.1103/PhysRevLett.92.074801, we first demonstrate that the collimation process preserves the slice beam quality, in agreement with our theoretical expectations, and that the collimation is compatible with the operation of a linear accelerator in terms of beam transport, radiation dose, and collimator heating. Accordingly, the collimated beam can be used for the generation of stable femtosecond soft x-ray pulses of tunable duration, from either a self-amplified spontaneous emission or an externally seeded free electron laser. The proposed method also turns out to be a more compact and cheaper solution for electron slice diagnostics than the commonly used radio frequency deflecting cavities and has minimal impact on the machine design.

  20. Low dose coronary CT angiography with 256-slice helical CT

    International Nuclear Information System (INIS)

    Zhang Xiaodong; Tang Binghang; Li Fangyun

    2011-01-01

    Objective: To compare the image quality and patient radiation dose of coronary computed tomography angiography (CCTA) received by prospectively-gated step-and-shoot (SAS) technique with those obtained by retrospectively-gated spiral ( RGS) technique on a 256-slice CT scanner. Methods: A total of 200 patients were enrolled in this study. One hundred patients underwent CCTA with SAS mode were subdivided into two groups: (1) 50 patients with an average heart rate (HR) ≤ 70 bpm were scanned with a data acquisition time window centered at the 75% of the R-R cycle (group A) and (2) 50 patients with HR > 70 bpm were scanned with the data acquisition time window centered at the 45% of the R-R cycle, including a phase tolerance of ± 5% (group B). Other 100 patients underwent CCTA with RGS mode and ECG-based tube current modulation were also subdivided into two groups: (3) 50 patients with HR ≤ 70 bpm were scanned with cardiac dose right set to phase of 75% ( group C) and (4) 50 patients with HR > 70 bpm were scanned with cardiac ose Rdight set to phases of 45% and 75% (group D). All patients were grouped in randomized order. The image quality of CCTA were evaluated using a rank scale from 1 to 4 (1: excellent; 4: non-assessable). Radiation dose of the four groups received was also estimated. The image quality between groups was compared by Mann-Whitney U test. The radiation dose between groups was compared by t test. For the 100 patients received by prospective ECG-gated CCTA, the receiver operating characteristic curve (ROC) was used to analyze the CCTA image quality and average heart rate to determine the uppercutoff of HR for obtaining diagnostic coronary images with SAS mode. A Spearman correlation analysis was also performed to analyze the correlation of HR and image quality in patients underwent CCTA with SAS mode. Results: Of 2338 coronary artery segments, excellent or good image quality (score of 1 or 2) was achieved in 96.5% (585 of 606) in group A, 77.7% (445

  1. Hysteresis Bearingless Slice Motors with Homopolar Flux-biasing.

    Science.gov (United States)

    Noh, Minkyun; Gruber, Wolfgang; Trumper, David L

    2017-10-01

    We present a new concept of bearingless slice motor that levitates and rotates a ring-shaped solid rotor. The rotor is made of a semi-hard magnetic material exhibiting magnetic hysteresis, such as D2 steel. The rotor is radially biased with a homopolar permanent-magnetic flux, on which the stator can superimpose 2-pole flux to generate suspension forces. By regulating the suspension forces based on position feedback, the two radial rotor degrees of freedom are actively stabilized. The two tilting degrees of freedom and the axial translation are passively stable due to the reluctance forces from the bias flux. In addition, the stator can generate a torque by superimposing 6- pole rotating flux, which drags the rotor via hysteresis coupling. This 6-pole flux does not generate radial forces in conjunction with the homopolar flux or 2-pole flux, and therefore the suspension force generation is in principle decoupled from the driving torque generation. We have developed a prototype system as a proof of concept. The stator has twelve teeth, each of which has a single phase winding that is individually driven by a linear transconductance power amplifier. The system has four reflective-type optical sensors to differentially measure the two radial degrees of freedom of the rotor. The suspension control loop is implemented such that the phase margin is 25 degrees at the cross-over frequency of 110 Hz. The prototype system can levitate the rotor and drive it up to about 1730 rpm. The maximum driving torque is about 2.7 mNm.

  2. Influence of slice overlap on positron emission tomography image quality

    International Nuclear Information System (INIS)

    McKeown, Clare; Gillen, Gerry; Dempsey, Mary Frances; Findlay, Caroline

    2016-01-01

    PET scans use overlapping acquisition beds to correct for reduced sensitivity at bed edges. The optimum overlap size for the General Electric (GE) Discovery 690 has not been established. This study assesses how image quality is affected by slice overlap. Efficacy of 23% overlaps (recommended by GE) and 49% overlaps (maximum possible overlap) were specifically assessed. European Association of Nuclear Medicine (EANM) guidelines for calculating minimum injected activities based on overlap size were also reviewed. A uniform flood phantom was used to assess noise (coefficient of variation, (COV)) and voxel accuracy (activity concentrations, Bq ml −1 ). A NEMA (National Electrical Manufacturers Association) body phantom with hot/cold spheres in a background activity was used to assess contrast recovery coefficients (CRCs) and signal to noise ratios (SNR). Different overlap sizes and sphere-to-background ratios were assessed. COVs for 49% and 23% overlaps were 9% and 13% respectively. This increased noise was difficult to visualise on the 23% overlap images. Mean voxel activity concentrations were not affected by overlap size. No clinically significant differences in CRCs were observed. However, visibility and SNR of small, low contrast spheres (⩽13 mm diameter, 2:1 sphere to background ratio) may be affected by overlap size in low count studies if they are located in the overlap area. There was minimal detectable influence on image quality in terms of noise, mean activity concentrations or mean CRCs when comparing 23% overlap with 49% overlap. Detectability of small, low contrast lesions may be affected in low count studies—however, this is a worst-case scenario. The marginal benefits of increasing overlap from 23% to 49% are likely to be offset by increased patient scan times. A 23% overlap is therefore appropriate for clinical use. An amendment to EANM guidelines for calculating injected activities is also proposed which better reflects the effect overlap size

  3. Tissue types (image)

    Science.gov (United States)

    ... are 4 basic types of tissue: connective tissue, epithelial tissue, muscle tissue, and nervous tissue. Connective tissue supports ... binds them together (bone, blood, and lymph tissues). Epithelial tissue provides a covering (skin, the linings of the ...

  4. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    Energy Technology Data Exchange (ETDEWEB)

    Ng, H.P. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Foong, K.W.C. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Dept. of Preventive Dentistry, National Univ. of Singapore (Singapore); Ong, S.H. [Dept. of Electrical and Computer Engineering, National Univ. of Singapore (Singapore); Div. of Bioengineering, National Univ. of Singapore (Singapore); Liu, J.; Nowinski, W.L. [Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Goh, P.S. [Dept. of Diagnostic Radiology, National Univ. of Singapore (Singapore)

    2007-06-15

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices ({kappa}) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  5. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    International Nuclear Information System (INIS)

    Ng, H.P.; Foong, K.W.C.; Ong, S.H.; Liu, J.; Nowinski, W.L.; Goh, P.S.

    2007-01-01

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices (κ) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  6. Organotypic slice cultures containing the preBötzinger complex generate respiratory-like rhythms

    DEFF Research Database (Denmark)

    Phillips, Wiktor S; Herly, Mikkel; Del Negro, Christopher A

    2016-01-01

    containing the preBötzinger complex (preBötC), the core inspiratory rhythm generator of the ventrolateral brainstem. We measured bilateral synchronous network oscillations, using calcium-sensitive fluorescent dyes, in both ventrolateral (presumably the preBötC) and dorsomedial regions of 7-43 days in vitro......Acute brainstem slice preparations in vitro have advanced understanding of the cellular and synaptic mechanisms of respiratory rhythm generation, but their inherent limitations preclude long-term manipulation and recording experiments. Here, we developed an organotypic slice culture preparation...... of the brainstem displayed up to 193% faster burst frequency (22.4 ± 8.3 bursts/min) and higher signal amplitude (340%) compared to acute slices. We conclude that preBötC-containing slice cultures retain inspiratory-like rhythmic function and therefore may facilitate lines of experimentation that involve extended...

  7. Principles, Techniques, and Applications of Tissue Microfluidics

    Science.gov (United States)

    Wade, Lawrence A.; Kartalov, Emil P.; Shibata, Darryl; Taylor, Clive

    2011-01-01

    The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called "tissue microfluidics" because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets.

  8. Fluidized bed drying characteristics and modeling of ginger ( zingiber officinale) slices

    Science.gov (United States)

    Parlak, Nezaket

    2015-08-01

    In this study fluidized bed drying characteristics of ginger have been investigated. The effects of the fluidizing air temperature, velocity, humidity and bed height on the drying performance of ginger slices have been found. The experimental moisture loss data of ginger slices has been fitted to the eight thin layer drying models. Two-term model drying model has shown a better fit to the experimental data with R2 of 0.998 as compared to others.

  9. [3H]Dopamine accumulation and release from striatal slices in young, mature and senescent rats

    International Nuclear Information System (INIS)

    Thompson, J.M.

    1981-01-01

    Examinations of [ 3 H]dopamine ([ 3 H]DA) release following KCl or amphetamine administration in striatal slices from young (7 month), mature (12 month) and senescent (24 month) Wistar rats showed no age-related changes. Further, the amount of [ 3 H]DA accumulated in the striatal slices showed no changes with age. Thus, previously reported age-related deficits in motor behavior (i.e. rotational) are not produced by changes in striatal DA accumulation or release. (Auth.)

  10. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  11. Drying characteristics of pumpkin ( Cucurbita moschata) slices in convective and freeze dryer

    Science.gov (United States)

    Caliskan, Gulsah; Dirim, Safiye Nur

    2017-06-01

    This study was intended to determine the drying and rehydration kinetics of convective and freeze dried pumpkin slices (0.5 × 3.5 × 0.5 cm). A pilot scale tray drier (at 80 ± 2 °C inlet temperature, 1 m s-1 air velocity) and freeze drier (13.33 kPa absolute pressure, condenser temperature of -48 ± 2 °C) were used for the drying experiments. Drying curves were fitted to six well-known thin layer drying models. Nonlinear regression analysis was used to evaluate the parameters of the selected models by using statistical software SPSS 16.0 (SPSS Inc., USA). For the convective and freeze drying processes of pumpkin slices, the highest R2 values, and the lowest RMSE as well as χ2 values were obtained from Page model. The effective moisture diffusivity (Deff) of the convective and freeze dried pumpkin slices were obtained from the Fick's diffusion model, and they were found to be 2.233 × 10-7 and 3.040 × 10-9 m2s-1, respectively. Specific moisture extraction rate, moisture extraction rate, and specific energy consumption values were almost twice in freeze drying process. Depending on the results, moisture contents and water activity values of pumpkin slices were in acceptable limits for safe storage of products. The rehydration behaviour of [at 18 ± 2 and 100 ± 2 °C for 1:25, 1:50, 1:75, 1:100, and 1:125 solid:liquid ratios (w:w)] dried pumpkin slices was determined by Peleg's model with the highest R2. The highest total soluble solid loss of pumpkin slices was observed for the rehydration experiment which performed at 1:25 solid: liquid ratio (w:w). Rehydration ratio of freeze dried slices was found 2-3 times higher than convective dried slices.

  12. Re-use of Low Bandwidth Equipment for High Bit Rate Transmission Using Signal Slicing Technique

    DEFF Research Database (Denmark)

    Wagner, Christoph; Spolitis, S.; Vegas Olmos, Juan José

    : Massive fiber-to-the-home network deployment requires never ending equipment upgrades operating at higher bandwidth. We show effective signal slicing method, which can reuse low bandwidth opto-electronical components for optical communications at higher bit rates.......: Massive fiber-to-the-home network deployment requires never ending equipment upgrades operating at higher bandwidth. We show effective signal slicing method, which can reuse low bandwidth opto-electronical components for optical communications at higher bit rates....

  13. Thin slices of friendship: do non-verbal behaviors predict first impressions during getting acquainted interactions?

    OpenAIRE

    Urgancı, Betül

    2017-01-01

    Cataloged from PDF version of article. Thesis (M.S.): Bilkent University, Department of Psychology, İhsan Doğramacı Bilkent University, 2017. Includes bibliographical references (leaves 28-32). Does a very brief observation of a person predict first impressions? Prior research has shown that these brief observations, called thin slices, predict many psychological outcomes such as individual performance. However, there is a not much research investigating whether thin slices predict f...

  14. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  15. Evaluation of the possibility to use thick slabs of reconstructed outer breast tomosynthesis slice images

    Science.gov (United States)

    Petersson, Hannie; Dustler, Magnus; Tingberg, Anders; Timberg, Pontus

    2016-03-01

    The large image volumes in breast tomosynthesis (BT) have led to large amounts of data and a heavy workload for breast radiologists. The number of slice images can be decreased by combining adjacent image planes (slabbing) but the decrease in depth resolution can considerably affect the detection of lesions. The aim of this work was to assess if thicker slabbing of the outer slice images (where lesions seldom are present) could be a viable alternative in order to reduce the number of slice images in BT image volumes. The suggested slabbing (an image volume with thick outer slabs and thin slices between) were evaluated in two steps. Firstly, a survey of the depth of 65 cancer lesions within the breast was performed to estimate how many lesions would be affected by outer slabs of different thicknesses. Secondly, a selection of 24 lesions was reconstructed with 2, 6 and 10 mm slab thickness to evaluate how the appearance of lesions located in the thicker slabs would be affected. The results show that few malignant breast lesions are located at a depth less than 10 mm from the surface (especially for breast thicknesses of 50 mm and above). Reconstruction of BT volumes with 6 mm slab thickness yields an image quality that is sufficient for lesion detection for a majority of the investigated cases. Together, this indicates that thicker slabbing of the outer slice images is a promising option in order to reduce the number of slice images in BT image volumes.

  16. Equilibrium initial data for moving puncture simulations: the stationary 1 + log slicing

    International Nuclear Information System (INIS)

    Baumgarte, T W; Matera, K; Etienne, Z B; Liu, Y T; Shapiro, S L; Taniguchi, K; Murchadha, N O

    2009-01-01

    We discuss a 'stationary 1 + log' slicing condition for the construction of solutions to Einstein's constraint equations. For stationary spacetimes, these initial data give a stationary foliation when evolved with 'moving puncture' gauge conditions that are often used in black hole evolutions. The resulting slicing is time independent and agrees with the slicing generated by being dragged along a timelike Killing vector of the spacetime. When these initial data are evolved with moving puncture gauge conditions, numerical errors arising from coordinate evolution should be minimized. While these properties appear very promising, suggesting that this slicing condition should be an attractive alternative to, for example, maximal slicing, we demonstrate in this paper that solutions can be constructed only for a small class of problems. For binary black hole initial data, in particular, it is often assumed that there exists an approximate helical Killing vector that generates the binary's orbit. We show that 1 + log slices that are stationary with respect to such a helical Killing vector cannot be asymptotically flat, unless the spacetime possesses an additional axial Killing vector.

  17. Estimation of radiation exposure of prospectively triggered 128-slice computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, D.; Fenchel, M.; Thomas, C.; Boehringer, N.; Tsiflikas, I.; Kaempf, M.; Syha, R.; Claussen, C.D.; Heuschmid, M. [Tuebingen Univ. (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Buchgeister, M. [Tuebingen Univ. (Germany). Medizinische Physik

    2010-12-15

    Purpose: To estimate the effective dose of prospectively triggered computed tomography coronary angiography (CTCA) in step-and-shoot (SAS) mode, depending on the tube current and tube voltage modulation. Materials and Methods: For dose measurements, an Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a 128-slice single source scanner providing a collimation of 128 x 0.6 mm and a rotation time of 0.38 seconds. CTCA in the SAS mode was acquired with variation of the tube current (160, 240, 320 mAs) and tube voltage (100, 120, 140 kV) at a simulated heart rate of 60 beats per minute and a scan range of 13.5 cm. Results: Depending on gender, tube current and tube voltage, the effective dose of a CTCA in SAS mode varies from 2.8 to 10.8 mSv. Due to breast tissue in the primary scan range, exposure in the case of females showed an increase of up to 60.0 {+-}.4 % compared to males. The dose reduction achieved by a reduction of tube current showed a significant positive, linear correlation to effective dose with a possible decrease in the effective dose of up to 60.4 % (r = 0.998; p = 0.044). Disproportionately high, the estimated effective dose can be reduced by using a lower tube voltage with a dose reduction of up to 52.4 %. Conclusion: Further substantial dose reduction of low-dose CTCA in SAS mode can be achieved by adapting the tube current and tube voltage and should be implemented in the clinical routine, i.e. adapting those protocol parameters to patient body weight. (orig.).

  18. Role of whole-body 64-slice multidetector computed tomography in treatment planning for multiple myeloma.

    Science.gov (United States)

    Razek, Ahmed Abdel Khalek Abdel; Ezzat, Amany; Azmy, Emad; Tharwat, Nehal

    2013-08-01

    The authors evaluated the role of whole-body 64-slice multidetector computed tomography (WB-MDCT) in treatment planning for multiple myeloma. This was a prospective study of 28 consecutive patients with multiple myeloma (19 men, nine women; age range, 51-73 years; mean age, 60 years) who underwent WB-MDCT and conventional radiography (CR) of the skeleton. The images were interpreted for the presence of bony lesions, medullary lesions, fractures and extraosseous lesions. We evaluated any changes in treatment planning as a result of WB-MDCT findings. WB-MDCT was superior to CR for detecting bony lesions (p=0.001), especially of the spine (p=0.001) and thoracic cage (p=0.006). WB-MDCT upstaged 14 patients, with a significant difference in staging (p=0.002) between WB-MDCT and CR. Medullary involvement either focal (n=6) or diffuse (n=3) had a positive correlation with the overall score (r=0.790) and stage (r=0.618) of disease. Spine fractures were better detected at WB-MDCT (n=4) than at CR (n=2). Extraosseous soft tissue lesions (n=7) were detected only at WB-MDCT. Findings detected at the WB-MDCT led to changes in the patient's treatment plan in 39% of cases. Upstaging of seven patients (25%) altered the medical treatment plan, and four of 28 (14%) patients required additional radiotherapy (7%) and vertebroplasty (7%). We conclude that WB-MDCT has an impact on treatment planning and prognosis in patients with multiple myeloma, as it has high rate of detecting cortical and medullary bone lesions, spinal fracture and extraosseous lesions. This information may alter treatment planning in multiple myeloma due to disease upstaging and detection of spine fracture and extraosseous spinal lesions.

  19. Natural innate cytokine response to immunomodulators and adjuvants in human precision-cut lung slices.

    Science.gov (United States)

    Switalla, S; Lauenstein, L; Prenzler, F; Knothe, S; Förster, C; Fieguth, H-G; Pfennig, O; Schaumann, F; Martin, C; Guzman, C A; Ebensen, T; Müller, M; Hohlfeld, J M; Krug, N; Braun, A; Sewald, K

    2010-08-01

    Prediction of lung innate immune responses is critical for developing new drugs. Well-established immune modulators like lipopolysaccharides (LPS) can elicit a wide range of immunological effects. They are involved in acute lung diseases such as infections or chronic airway diseases such as COPD. LPS has a strong adjuvant activity, but its pyrogenicity has precluded therapeutic use. The bacterial lipopeptide MALP-2 and its synthetic derivative BPPcysMPEG are better tolerated. We have compared the effects of LPS and BPPcysMPEG on the innate immune response in human precision-cut lung slices. Cytokine responses were quantified by ELISA, Luminex, and Meso Scale Discovery technology. The initial response to LPS and BPPcysMPEG was marked by coordinated and significant release of the mediators IL-1β, MIP-1β, and IL-10 in viable PCLS. Stimulation of lung tissue with BPPcysMPEG, however, induced a differential response. While LPS upregulated IFN-γ, BPPcysMPEG did not. This traces back to their signaling pathways via TLR4 and TLR2/6. The calculated exposure doses selected for LPS covered ranges occurring in clinical studies with human beings. Correlation of obtained data with data from human BAL fluid after segmental provocation with endotoxin showed highly comparable effects, resulting in a coefficient of correlation >0.9. Furthermore, we were interested in modulating the response to LPS. Using dexamethasone as an immunosuppressive drug for anti-inflammatory therapy, we found a significant reduction of GM-CSF, IL-1β, and IFN-γ. The PCLS-model offers the unique opportunity to test the efficacy and toxicity of biological agents intended for use by inhalation in a complex setting in humans. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Dynamic bowtie filter for cone-beam/multi-slice CT.

    Directory of Open Access Journals (Sweden)

    Fenglin Liu

    Full Text Available A pre-patient attenuator ("bowtie filter" or "bowtie" is used to modulate an incoming x-ray beam as a function of the angle of the x-ray with respect to a patient to balance the photon flux on a detector array. While the current dynamic bowtie design is focused on fan-beam geometry, in this study we propose a methodology for dynamic bowtie design in multi-slice/cone-beam geometry. The proposed 3D dynamic bowtie is an extension of the 2D prior art. The 3D bowtie consists of a highly attenuating bowtie (HB filled in with heavy liquid and a weakly attenuating bowtie (WB immersed in the liquid of the HB. The HB targets a balanced flux distribution on a detector array when no object is in the field of view (FOV. The WB compensates for an object in the FOV, and hence is a scaled-down version of the object. The WB is rotated and translated in synchrony with the source rotation and patient translation so that the overall flux balance is maintained on the detector array. First, the mathematical models of different scanning modes are established for an elliptical water phantom. Then, a numerical simulation study is performed to compare the performance of the scanning modes in the cases of the water phantom and a patient cross-section without any bowtie and with a dynamic bowtie. The dynamic bowtie can equalize the numbers of detected photons in the case of the water phantom. In practical cases, the dynamic bowtie can effectively reduce the dynamic range of detected signals inside the FOV. Furthermore, the WB can be individualized using a 3D printing technique as the gold standard. We have extended the dynamic bowtie concept from 2D to 3D by using highly attenuating liquid and moving a scale-reduced negative copy of an object being scanned. Our methodology can be applied to reduce radiation dose and facilitate photon-counting detection.

  1. The anal verge: localization with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Wei; Tang Guangjian

    2010-01-01

    Objective: To determine and evaluate the method of localization of anal verge by multislice spiral CT. To provide an imaging reference for operative guidance of low-rectal cancer. Methods Forty eight consecutive adult patients suspected of abnormalities other than rectal disease were evaluated with abdominal and pelvic CT scans since August, 2009. They were divided into two groups based on sex and age. There were 23 men and 25 women. The ages of young group were 28 to 50 years and the average age was 41 years. The ages of elderly group were 52 to 81 years and the average age was 64 years. A small cotton ball dipped with contrast media was put at the anal verge as a marker and CT scans were performed with 64-slice spiral CT scanner. The distances between the cotton balls and the lower margin of the pubis combination (La), the lower margin of the Sth sacral vertebra (Lb), the inferior aperture of minor pelvis (Lc) and the lower margin of the basement of external anal sphincter (Ld) were measured on the mid- sagittal images obtained by MPR. The averages, the standard deviations (s), the 95% and 80% confidence intervals of La, Lb, Lc and Ld were calculated. We took the intervals of ±1.96 s or ±1.28 s 0.05) between two different sex groups [male group, (10.0±1.2) mm], female group, (9.6±1.2) mm and between two age groups [young group, (9.6±1.2) mm, elderly group, (9.9±1.3) mm]. Conclusions: The lower margin of the basement of external anal sphincter was a useful anatomic landmark for localizing the anal verge, and could be definitely identified on the middle sagittal pelvic CT image. The distance between the structure and anal verge is constant enough and can be used in measuring distance from low rectal lesion to the anal verge. (authors)

  2. Demonstration of the pulmonary interlobar fissures on multiplanar reformatted images with 64-slices spiral CT

    International Nuclear Information System (INIS)

    Wang Yafei; Chen Yerong; Shan Xiuhong; Tang Zhiyang; Ni Enzhen; Huang Hao; Wu Shuchun

    2009-01-01

    Objective: To determine the optimal orientation and slice thickness of reformatted images to visualize the interlobar fissures on multiplanar reformation (MPR) images and to recommend MPR imaging protocal for visualizing interlobar fissures in clinical practise. Methods: 64-slices CT scans of chest were obtained in 300 patients without pulmonary diseases. Axial, sagittal and coronal images were reformatted at 1, 2, 3, 7 mm slice thickness respectively from the raw volume data. Three experienced radiologists evaluated all of the MPR images in the lung window and compared the differences in visualization of the interlohar fissures among the three reformatted orientations and at the different slice thicknesses with Fisher test and Friedman test. Results: Fissures on sagittal MPR images using 1, 2, 3, and 7 mm reformatted slice thickness appeared as a fine line and the preference value analysis showed the MPR images with a 3 mm reformatted slice thickness is the best for visualizing the interlobar fissure. Compared to the sagittal orientation, the coronal was not as good and the axial was the worst among the three orientations. The coronal images with a 3 mm reformatted slice thickness were slightly inferior to sagittal images. The right horizontal fissures were observed as a fine line in all coronal image in 94.0% (282)of cases and in some of the images in 6.0% (18) of cases, the right oblique fissures were displayed as a fine line in coronal images in 2.3% (7) of cases and in some images in 85.0% (255) of cases, the left oblique fissures were displayed as a fine line in some coronal images in 35.7% (107) of cases and displayed as a coarse line in 64.3% (193) of cases. On axial MPR images using 3 mm reformation slice thickness, the right oblique fissures and the left oblique fissures were displayed as a fine line in some axial images in 79.3% (238) and 81.0% (243) of cases respectively, none of the images showed horizontal fissures as a fine line. There was

  3. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  4. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography

    International Nuclear Information System (INIS)

    Burgstahler, Christof; Reimann, Anja; Brodoefel, Harald; Tsiflikas, Ilias; Thomas, Christoph; Heuschmid, Martin; Daferner, Ulrike; Drosch, Tanja; Schroeder, Stephen; Herberts, Tina

    2009-01-01

    Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n=90; Siemens Sensation 64: n=91; Siemens Definition: n=75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347±13 vs. 254±14 (64-MSCT) vs. 233±11 (16-MSCT) HU], LM (362±11/275 ± 12/262±9), LAD (332±17/248±19/219±14) and LCX (310±12/210±13/221±10, all p<0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p<0.05). BMI had no impact on the CA ratio in DSCT only (p<0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a

  5. Study of distribution of /sup 169/Yb, /sup 67/Ga and /sup 111/In in tumor tissue by macroautoradiography. Comparison between viable tumor tissue and necrotic tumor tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ando, A; Sanada, S; Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine; Doishita, K; Ando, I

    1977-01-01

    The localization of /sup 169/Yb, /sup 67/Ga and /sup 111/In in tumor tissues was determined macroautoradiographically. /sup 169/Yb-citrate, /sup 67/Ga-citrate and /sup 111/In-citrate were injected intravenously into rats which had received subcutaneously transplantations of Yoshida sarcoma, and were injected intraperitoneally to the mice which had received subcutaneous transplantations of Ehrlich tumor. These animals were sacrificed 3, 24 and 48 hours after injection. The tumor tissues were frozen in n-hexane (-70/sup 0/C) cooled with dry ice-acetone. After this, the frozen tumor tissues were cut into thin serial sections (10 ..mu..m) in a cryostat (-20/sup 0/C). One of these sections was then placed on x-ray film, and this film was developed after exposure of several days. The next slice of each of these sections were stained using the hematoxylin and eosin. From the observations of these autoradiogram and H-E stained slice, the following results were obtained. Concentration of /sup 169/Yb, /sup 67/Ga and /sup 111/In was predominant in viable tumor tissue rather than in necrotic tumor tissue, regardless of time after administration. /sup 67/Ga and /sup 111/In were distributed uniformly in viable tumor tissue, but there was greater deposition of /sup 169/Yb in viable tumor tissue neighboring the necrotic tumor.

  6. Fragmentation process of vitrified ceramic waste (VCW) aiming its incorporation in silico-aluminous refractory concrete for production of refractory bricks; Processo de fragmentacao de residuos ceramicos vitrificados (RCV) visando sua incorporacao em concreto refratario silico-aluminoso

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, L.B.; Brandalise, R.N.; Santos, V. dos, E-mail: lbgomes@ucs.br [Universidade de Caxias do Sul (UCS), RS (Brazil); Bergmann, C.P. [Universidade Federal do Rio Grande do Sul (UFRGS), RS (Brazil)

    2012-07-01

    Ceramic industry generates large amounts of waste, usually disposed in landfills. Reuse could minimize their generation and provides sustainable solutions. However, the energy cost of grinding these waste becomes a hindrance to their reuse. This work aims to obtain particle sizes of vitrified ceramic waste (VCW) using a fast, efficient and low cost fragmentation process as well as its use in refractory concrete. The results shows a wide range of particle size of VCW, which can be used as a promising source of raw material for production of refractory concrete. (author)

  7. Influence of image slice thickness on rectal dose–response relationships following radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Olsson, C; Thor, M; Apte, A; Deasy, J O; Liu, M; Moissenko, V; Petersen, S E; Høyer, M

    2014-01-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose–response relationships. We investigated this for rectal bleeding using dose–volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman–Kutcher–Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose–response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice

  8. Influence of image slice thickness on rectal dose-response relationships following radiotherapy of prostate cancer

    Science.gov (United States)

    Olsson, C.; Thor, M.; Liu, M.; Moissenko, V.; Petersen, S. E.; Høyer, M.; Apte, A.; Deasy, J. O.

    2014-07-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose-response relationships. We investigated this for rectal bleeding using dose-volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman-Kutcher-Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose-response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice thickness

  9. Spontaneous calcium waves in granule cells in cerebellar slice cultures

    DEFF Research Database (Denmark)

    Apuschkin, Mia; Ougaard, Maria; Rekling, Jens C

    2013-01-01

    Multiple regions in the CNS display propagating correlated activity during embryonic and postnatal development. This activity can be recorded as waves of increased calcium concentrations in spiking neurons or glia cells, and have been suggested to be involved in patterning, axonal guidance and es......, that the propagating wave activity is carried through the tissue by axonal collaterals formed by neighboring granule cells, and further suggest that the correlated activity may be related to processes that ensure correct postnatal wiring of the cerebellar circuits....

  10. Tissue Classification

    DEFF Research Database (Denmark)

    Van Leemput, Koen; Puonti, Oula

    2015-01-01

    Computational methods for automatically segmenting magnetic resonance images of the brain have seen tremendous advances in recent years. So-called tissue classification techniques, aimed at extracting the three main brain tissue classes (white matter, gray matter, and cerebrospinal fluid), are now...... well established. In their simplest form, these methods classify voxels independently based on their intensity alone, although much more sophisticated models are typically used in practice. This article aims to give an overview of often-used computational techniques for brain tissue classification...

  11. Clinical feasibility of simultaneous multi-slice imaging with blipped-CAIPI for diffusion-weighted imaging and diffusion-tensor imaging of the brain.

    Science.gov (United States)

    Yokota, Hajime; Sakai, Koji; Tazoe, Jun; Goto, Mariko; Imai, Hiroshi; Teramukai, Satoshi; Yamada, Kei

    2017-12-01

    Background Simultaneous multi-slice (SMS) imaging is starting to be used in clinical situation, although evidence of clinical feasibility is scanty. Purpose To prospectively assess the clinical feasibility of SMS diffusion-weighted imaging (DWI) and diffusion-tensor imaging (DTI) with blipped-controlled aliasing in parallel imaging for brain lesions. Material and Methods The institutional review board approved this study. This study included 156 hyperintense lesions on DWI from 32 patients. A slice acceleration factor of 2 was applied for SMS scans, which allowed shortening of the scan time by 41.3%. The signal-to-noise ratio (SNR) was calculated for brain tissue of a selected slice. The contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC), and fractional anisotropy (FA) were calculated in 36 hyperintense lesions with a diameter of three pixels or more. Visual assessment was performed for all 156 lesions. Tractography of the corticospinal tract of 29 patients was evaluated. The number of tracts and averaged tract length were used for quantitative analysis, and visual assessment was evaluated by grading. Results The SMS scan showed no bias and acceptable 95% limits of agreement compared to conventional scans in SNR, CNR, and ADC on Bland-Altman analyses. Only FA of the lesions was higher in the SMS scan by 9% ( P = 0.016), whereas FA of the surrounding tissues was similar. Quantitative analysis of tractography showed similar values. Visual assessment of DWI hyperintense lesions and tractography also resulted in comparable evaluation. Conclusion SMS imaging was clinically feasible for imaging quality and quantitative values compared with conventional DWI and DTI.

  12. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Dibucaine mitigates spreading depolarization in human neocortical slices and prevents acute dendritic injury in the ischemic rodent neocortex.

    Directory of Open Access Journals (Sweden)

    W Christopher Risher

    Full Text Available Spreading depolarizations that occur in patients with malignant stroke, subarachnoid/intracranial hemorrhage, and traumatic brain injury are known to facilitate neuronal damage in metabolically compromised brain tissue. The dramatic failure of brain ion homeostasis caused by propagating spreading depolarizations results in neuronal and astroglial swelling. In essence, swelling is the initial response and a sign of the acute neuronal injury that follows if energy deprivation is maintained. Choosing spreading depolarizations as a target for therapeutic intervention, we have used human brain slices and in vivo real-time two-photon laser scanning microscopy in the mouse neocortex to study potentially useful therapeutics against spreading depolarization-induced injury.We have shown that anoxic or terminal depolarization, a spreading depolarization wave ignited in the ischemic core where neurons cannot repolarize, can be evoked in human slices from pediatric brains during simulated ischemia induced by oxygen/glucose deprivation or by exposure to ouabain. Changes in light transmittance (LT tracked terminal depolarization in time and space. Though spreading depolarizations are notoriously difficult to block, terminal depolarization onset was delayed by dibucaine, a local amide anesthetic and sodium channel blocker. Remarkably, the occurrence of ouabain-induced terminal depolarization was delayed at a concentration of 1 µM that preserves synaptic function. Moreover, in vivo two-photon imaging in the penumbra revealed that, though spreading depolarizations did still occur, spreading depolarization-induced dendritic injury was inhibited by dibucaine administered intravenously at 2.5 mg/kg in a mouse stroke model.Dibucaine mitigated the effects of spreading depolarization at a concentration that could be well-tolerated therapeutically. Hence, dibucaine is a promising candidate to protect the brain from ischemic injury with an approach that does not rely on

  14. Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A.; Rousseau, Francois; Glenn, Orit A.; Barkovich, Anthony J.; Studholme, Colin

    2012-01-01

    In recent years post-processing of fast multi-slice MR imaging to correct fetal motion has provided the first true 3D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two step iterative process, where slices from the acquired data are re-aligned to an approximate 3D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3D reconstruction, and is limited in its ability to recover sub-voxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3D reconstructions containing clinically useful additional information not visible in the original 2D slices. PMID:19744911

  15. Mis-estimation and bias of hyperpolarized apparent diffusion coefficient measurements due to slice profile effects.

    Science.gov (United States)

    Gordon, Jeremy W; Milshteyn, Eugene; Marco-Rius, Irene; Ohliger, Michael; Vigneron, Daniel B; Larson, Peder E Z

    2017-09-01

    The purpose of this work was to explore the impact of slice profile effects on apparent diffusion coefficient (ADC) mapping of hyperpolarized (HP) substrates. Slice profile effects were simulated using a Gaussian radiofrequency (RF) pulse with a variety of flip angle schedules and b-value ordering schemes. A long T 1 water phantom was used to validate the simulation results, and ADC mapping of HP [ 13 C, 15 N 2 ]urea was performed on the murine liver to assess these effects in vivo. Slice profile effects result in excess signal after repeated RF pulses, causing bias in HP measurements. The largest error occurs for metabolites with small ADCs, resulting in up to 10-fold overestimation for metabolites that are in more-restricted environments. A mixed b-value scheme substantially reduces this bias, whereas scaling the slice-select gradient can mitigate it completely. In vivo, the liver ADC of hyperpolarized [ 13 C, 15 N 2 ]urea is nearly 70% lower (0.99 ± 0.22 vs 1.69 ± 0.21 × 10 -3 mm 2 /s) when slice-select gradient scaling is used. Slice profile effects can lead to bias in HP ADC measurements. A mixed b-value ordering scheme can reduce this bias compared to sequential b-value ordering. Slice-select gradient scaling can also correct for this deviation, minimizing bias and providing more-precise ADC measurements of HP substrates. Magn Reson Med 78:1087-1092, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  16. Multi-slice CT urography after diuretic injection: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Wildberger, J.E.; Schmitz-Rode, T.; Guenther, R.W. [Technische Univ. Aachen (Germany). Dept. of Diagnostic Radiology; Borchers, H. [Technische Univ. Aachen (Germany). Dept. of Urology

    2001-03-01

    Purpose: To investigate the feasibility of CT urography (CTU) using a multi-slice (MS) scanner and to find out whether a low-dose diuretic injection is advantageous for the opacification of the urinary tract. Methods: MS-CTU was performed in 21 patients with urologic diseases. In 5/21 patients, 250 ml of physiologic saline solution were injected. In 16/21 patients, 10 mg of furosemide were injected 3-5 min before contrast material administration. A 4x2.5 mm collimation with a pitch of 1.25 and a tube curent of 100-150 mA were used. Scan time was 12-16 sec. 3 mm thin axial images with an overlap of 67% were reconstructed. Multiplanar maximum intensity projection (MIP) images were postprocessed to obtain urographic views. Bone structures were eliminated using the volume-of-interest method. Results: Furosemide-enhanced MS-CTU achieved either near complete or complete opacification in 30/32 (94%) ureters and in 32/32 (100%) pelvicaliceal systems up to a serum creatinine of 150 {mu}mol/l. In our series, only one CTU scan per patient was needed to obtain a diagnostic urogram after 10 min of contrast material injection. Ureteral compression was not necessary. When physiologic saline solution was used instead of furosemide, the radiopacity inside the enhanced pelvicalices was 4-5 times higher and more inhomogeneous. Diuretic-enhanced MS-CTU was more accurate in the depiction of pelvicaliceal details. In combination with furosemide, calculi were well identified inside the opacified urine and were safely differentiated from phleboliths. Postprocessing times of up to 20 minutes were problematic as were contrast-enhanced superimposing bowel loops on MIP images. Conclusion: Preliminary results demonstrate a good feasibility of furosemide-enhanced MS-CTU for obtaining detailed visualization of the entire upper urinary tract. (orig.) [German] Ziel: Untersuchung zur Durchfuehrbarkeit der CT Urographie (CTU) mit einem Multidetektor(MD)-Computertomographen und ob eine

  17. Successful vitrification and autografting of baboon (Papio anubis) ovarian tissue.

    Science.gov (United States)

    Amorim, Christiani A; Jacobs, Sophie; Devireddy, Ram V; Van Langendonckt, Anne; Vanacker, Julie; Jaeger, Jonathan; Luyckx, Valérie; Donnez, Jacques; Dolmans, Marie-Madeleine

    2013-08-01

    Can a vitrification protocol using an ethylene glycol/dimethyl sulphoxide-based solution and a cryopin successfully cryopreserve baboon ovarian tissue? Our results show that baboon ovarian tissue can be successfully cryopreserved with our vitrification protocol. Non-human primates have already been used as an animal model to test vitrification protocols for human ovarian tissue cryopreservation. Ovarian biopsies from five adult baboons were vitrified, warmed and autografted for 5 months. After grafting, follicle survival, growth and function and also the quality of stromal tissue were assessed histologically and by immunohistochemistry. The influence of the vitrification procedure on the cooling rate was evaluated by a computer model. After vitrification, warming and long-term grafting, follicles were able to grow and maintain their function, as illustrated by Ki67, anti-Müllerian hormone (AMH) and growth differentiation factor-9 (GDF-9) immunostaining. Corpora lutea were also observed, evidencing successful ovulation in all the animals. Stromal tissue quality did not appear to be negatively affected by our cryopreservation procedure, as demonstrated by vascularization and proportions of fibrotic areas, which were similar to those found in fresh ungrafted ovarian tissue. Despite our promising findings, before applying this technique in a clinical setting, we need to validate it by achieving pregnancies. In addition to encouraging results obtained with our vitrification procedure for non-human ovarian tissue, this study also showed, for the first time, expression of AMH and GDF-9 in ovarian follicles. This study was supported by grants from the Fonds National de la Recherche Scientifique de Belgique (grant Télévie No. 7.4507.10, grant 3.4.590.08 awarded to Marie-Madeleine Dolmans), Fonds Spéciaux de Recherche, Fondation St Luc, Foundation Against Cancer, and Department of Mechanical Engineering at Louisiana State University (support to Ram Devireddy), and

  18. Evaluation of registration strategies for multi-modality images of rat brain slices

    International Nuclear Information System (INIS)

    Palm, Christoph; Vieten, Andrea; Salber, Dagmar; Pietrzyk, Uwe

    2009-01-01

    In neuroscience, small-animal studies frequently involve dealing with series of images from multiple modalities such as histology and autoradiography. The consistent and bias-free restacking of multi-modality image series is obligatory as a starting point for subsequent non-rigid registration procedures and for quantitative comparisons with positron emission tomography (PET) and other in vivo data. Up to now, consistency between 2D slices without cross validation using an inherent 3D modality is frequently presumed to be close to the true morphology due to the smooth appearance of the contours of anatomical structures. However, in multi-modality stacks consistency is difficult to assess. In this work, consistency is defined in terms of smoothness of neighboring slices within a single modality and between different modalities. Registration bias denotes the distortion of the registered stack in comparison to the true 3D morphology and shape. Based on these metrics, different restacking strategies of multi-modality rat brain slices are experimentally evaluated. Experiments based on MRI-simulated and real dual-tracer autoradiograms reveal a clear bias of the restacked volume despite quantitatively high consistency and qualitatively smooth brain structures. However, different registration strategies yield different inter-consistency metrics. If no genuine 3D modality is available, the use of the so-called SOP (slice-order preferred) or MOSOP (modality-and-slice-order preferred) strategy is recommended.

  19. Imaging by the SSFSE single slice method at different viscosities of bile

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi [Kawasaki Hospital, Kobe (Japan)

    2001-11-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T{sub 2}. However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T{sub 2} value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T{sub 2} value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T{sub 1}- and T{sub 2}-weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T{sub 2} values of the bile samples showing relatively high signal intensities on the T{sub 1}-weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T{sub 1}-weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  20. Imaging by the SSFSE single slice method at different viscosities of bile

    International Nuclear Information System (INIS)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi

    2001-01-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T 2 . However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T 2 value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T 2 value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T 1 - and T 2 -weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T 2 values of the bile samples showing relatively high signal intensities on the T 1 -weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T 1 -weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  1. Free-breathing cardiac MR stress perfusion with real-time slice tracking.

    Science.gov (United States)

    Basha, Tamer A; Roujol, Sébastien; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza

    2014-09-01

    To develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise. We propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence. The proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy. The proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans. Copyright © 2013 Wiley Periodicals, Inc.

  2. Impact of whey protein coating incorporated with Bifidobacterium and Lactobacillus on sliced ham properties.

    Science.gov (United States)

    Odila Pereira, Joana; Soares, José; J P Monteiro, Maria; Gomes, Ana; Pintado, Manuela

    2018-05-01

    Edible coatings/films with functional ingredients may be a solution to consumers' demands for high-quality food products and an extended shelf-life. The aim of this work was to evaluate the antimicrobial efficiency of edible coatings incorporated with probiotics on sliced ham preservation. Coatings was developed based on whey protein isolates with incorporation of Bifidobacterium animalis Bb-12® or Lactobacillus casei-01. The physicochemical analyses showed that coating decreased water and weight loss on the ham. Furthermore, color analysis showed that coated sliced ham, exhibited no color change, comparatively to uncoated slices. The edible coatings incorporating the probiotic strains inhibited detectable growth of Staphylococcus spp., Pseudomonas spp., Enterobacteriaceae and yeasts/molds, at least, for 45days of storage at 4°C. The sensory evaluation demonstrated that there was a preference for the sliced coated ham. Probiotic bacteria viable cell numbers were maintained at ca. 10 8 CFU/g throughout storage time, enabling the slice of ham to act as a suitable carrier for the beneficial bacteria. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Prooxidant Effects of Verbascoside, a Bioactive Compound from Olive Oil Mill Wastewater, on In Vitro Developmental Potential of Ovine Prepubertal Oocytes and Bioenergetic/Oxidative Stress Parameters of Fresh and Vitrified Oocytes

    Science.gov (United States)

    Dell'Aquila, M. E.; Bogliolo, L.; Russo, R.; Martino, N. A.; Filioli Uranio, M.; Ariu, F.; Amati, F.; Sardanelli, A. M.; Linsalata, V.; Ferruzzi, M. G.; Cardinali, A.; Minervini, F.

    2014-01-01

    Verbascoside (VB) is a bioactive polyphenol from olive oil mill wastewater with known antioxidant activity. Oxidative stress is an emerging problem in assisted reproductive technology (ART). Juvenile ART is a promising topic because, in farm animals, it reduces the generation gap and, in human reproductive medicine, it helps to overcome premature ovarian failure. The aim of this study was to test the effects of VB on the developmental competence of ovine prepubertal oocytes and the bioenergetic/oxidative stress status of fresh and vitrified oocytes. In fresh oocytes, VB exerted prooxidant short-term effects, that is, catalase activity increase and uncoupled increases of mitochondria and reactive oxygen species (ROS) fluorescence signals, and long-term effects, that is, reduced blastocyst formation rate. In vitrified oocytes, VB increased ROS levels. Prooxidant VB effects in ovine prepubertal oocytes could be related to higher VB accumulation, which was found as almost one thousand times higher than that reported in other cell systems in previous studies. Also, long exposure times of oocytes to VB, throughout the duration of in vitro maturation culture, may have contributed to significant increase of oocyte oxidation. Further studies are needed to identify lower concentrations and/or shorter exposure times to figure out VB antioxidant effects in juvenile ARTs. PMID:24719893

  4. Prooxidant Effects of Verbascoside, a Bioactive Compound from Olive Oil Mill Wastewater, on In Vitro Developmental Potential of Ovine Prepubertal Oocytes and Bioenergetic/Oxidative Stress Parameters of Fresh and Vitrified Oocytes

    Directory of Open Access Journals (Sweden)

    M. E. Dell'Aquila

    2014-01-01

    Full Text Available Verbascoside (VB is a bioactive polyphenol from olive oil mill wastewater with known antioxidant activity. Oxidative stress is an emerging problem in assisted reproductive technology (ART. Juvenile ART is a promising topic because, in farm animals, it reduces the generation gap and, in human reproductive medicine, it helps to overcome premature ovarian failure. The aim of this study was to test the effects of VB on the developmental competence of ovine prepubertal oocytes and the bioenergetic/oxidative stress status of fresh and vitrified oocytes. In fresh oocytes, VB exerted prooxidant short-term effects, that is, catalase activity increase and uncoupled increases of mitochondria and reactive oxygen species (ROS fluorescence signals, and long-term effects, that is, reduced blastocyst formation rate. In vitrified oocytes, VB increased ROS levels. Prooxidant VB effects in ovine prepubertal oocytes could be related to higher VB accumulation, which was found as almost one thousand times higher than that reported in other cell systems in previous studies. Also, long exposure times of oocytes to VB, throughout the duration of in vitro maturation culture, may have contributed to significant increase of oocyte oxidation. Further studies are needed to identify lower concentrations and/or shorter exposure times to figure out VB antioxidant effects in juvenile ARTs.

  5. Unbiased stereological estimation of d-dimensional volume in Rn from an isotropic random slice through a fixed point

    DEFF Research Database (Denmark)

    Jensen, Eva B. Vedel; Kiêu, K

    1994-01-01

    Unbiased stereological estimators of d-dimensional volume in R(n) are derived, based on information from an isotropic random r-slice through a specified point. The content of the slice can be subsampled by means of a spatial grid. The estimators depend only on spatial distances. As a fundamental ...... lemma, an explicit formula for the probability that an isotropic random r-slice in R(n) through 0 hits a fixed point in R(n) is given....

  6. Using a high-speed movie camera to evaluate slice dropping in clinical image interpretation with stack mode viewers.

    OpenAIRE

    Yakami, Masahiro; Yamamoto, Akira; Yanagisawa, Morio; Sekiguchi, Hiroyuki; Kubo, Takeshi; Togashi, Kaori

    2013-01-01

    The purpose of this study is to verify objectively the rate of slice omission during paging on picture archiving and communication system (PACS) viewers by recording the images shown on the computer displays of these viewers with a high-speed movie camera. This study was approved by the institutional review board. A sequential number from 1 to 250 was superimposed on each slice of a series of clinical Digital Imaging and Communication in Medicine (DICOM) data. The slices were displayed using ...

  7. Dosimetric variation due to CT inter-slice spacing in four-dimensional carbon beam lung therapy

    International Nuclear Information System (INIS)

    Kumagai, Motoki; Mori, Shinichiro; Kandatsu, Susumu; Baba, Masayuki; Sharp, Gregory C; Asakura, Hiroshi; Endo, Masahiro

    2009-01-01

    When CT data with thick slice thickness are used in treatment planning, geometrical uncertainty may induce dosimetric errors. We evaluated carbon ion dose variations due to different CT slice thicknesses using a four-dimensional (4D) carbon ion beam dose calculation, and compared results between ungated and gated respiratory strategies. Seven lung patients were scanned in 4D mode with a 0.5 mm slice thickness using a 256-multi-slice CT scanner. CT images were averaged with various numbers of images to simulate reconstructed images with various slice thicknesses (0.5-5.0 mm). Two scenarios were studied (respiratory-ungated and -gated strategies). Range compensators were designed for each of the CT volumes with coarse inter-slice spacing to cover the internal target volume (ITV), as defined from 4DCT. Carbon ion dose distribution was computed for each resulting ITV on the 0.5 mm slice 4DCT data. The accumulated dose distribution was then calculated using deformable registration for 4D dose assessment. The magnitude of over- and under-dosage was found to be larger with the use of range compensators designed with a coarser inter-slice spacing than those obtained with a 0.5 mm slice thickness. Although no under-dosage was observed within the clinical target volume (CTV) region, D95 remained at over 97% of the prescribed dose for the ungated strategy and 95% for the gated strategy for all slice thicknesses. An inter-slice spacing of less than 3 mm may be able to minimize dose variation between the ungated and gated strategies. Although volumes with increased inter-slice spacing may reduce geometrical accuracy at a certain respiratory phase, this does not significantly affect delivery of the accumulated dose to the target during the treatment course.

  8. Tomographic apparatus and method for reconstructing planar slices from non-absorbed radiation

    International Nuclear Information System (INIS)

    1976-01-01

    In a tomographic apparatus and method for reconstructing two-dimensional planar slices from linear projections of non-absorbed radiation useful in the fields of medical radiology, microscopy, and non-destructive testing, a beam of radiation in the shape of a fan is passed through an object lying in the same quasi-plane as the object slice and non-absorbtion thereof is recorded on oppositely-situated detectors aligned with the source of radiation. There is relative rotation between the source-detector configuration and the object within the quasi-plane. Periodic values of the detected radiation are taken, convolved with certain functions, and back-projected to produce a two-dimensional output picture on a visual display illustrating a facsimile of the object slice. A series of two-dimensional pictures obtained simultaneously or serially can be combined to produce a three dimensional portrayal of the entire object

  9. Extension of shelf-life of Chickoo slices using hurdle technology

    International Nuclear Information System (INIS)

    Shirodkar, S.; Behere, A.G.; Padwal-Desai, S.R.; Lele, S.S.; Pai, J.S.

    2001-01-01

    An attempt has been made to evolve a protocol to prepare shelf-stable high moisture chickoo slices using Hurdle Technology. The process is based on a slight reduction of water activity (0.98?0.94) by osmosis with a 70 deg Brix sucrose syrup, lowering of pH (5.75 to 4.46) by addition of citric acid, addition of KMS and then subjecting the resulting slices to different doses of gamma radiation ranging from 0.25-1 kGy. Radiation processed chickoo slices remained acceptable for 8 weeks at sub-room temperature (10 ± 2 degC) and for 3 weeks at ambient temperature (28 ± 2 degC) when evaluated by a taste-test panel. (author)

  10. Microbial growth and sensory quality of dried potato slices irradiated by electrons

    International Nuclear Information System (INIS)

    Kim, Hyun-Jin; Song, Hyeon-Jeong; Song, Kyung-Bin

    2011-01-01

    Electron beam irradiation was applied to secure the microbial safety of dried purple sweet potato. After purple sweet potato slices had been dehydrated with 20% (w/w) maltodextrin solution, the samples were irradiated at doses 2, 4, 6, 8, and 10 kGy and then stored at 20 o C for 60 days. Microbiological data indicated that the populations of total aerobic bacteria and of yeast and molds significantly decreased with increase in irradiation dosage. Specifically, microbial load was reduced by about three log cycles at 6 kGy compared to those of the control. Based on the color measurement of the potato slices, electron beam irradiation treatment did not affect the color quality. Sensory evaluation results also showed that electron beam irradiation did not affect overall sensory scores during storage. These results suggest that electron beam irradiation could be useful for improving microbial safety without impairing the quality of the potato slices during storage.

  11. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  12. A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    Science.gov (United States)

    Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin

    2018-07-01

    Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Intersection-based registration of slice stacks to form 3D images of the human fetal brain

    DEFF Research Database (Denmark)

    Kim, Kio; Hansen, Mads Fogtmann; Habas, Piotr

    2008-01-01

    Clinical fetal MR imaging of the brain commonly makes use of fast 2D acquisitions of multiple sets of approximately orthogonal 2D slices. We and others have previously proposed an iterative slice-to-volume registration process to recover a geometrically consistent 3D image. However......, these approaches depend on a 3D volume reconstruction step during the slice alignment. This is both computationally expensive and makes the convergence of the registration process poorly defined. In this paper our key contribution is a new approach which considers the collective alignment of all slices directly...... of the approach applied to simulated data and clinically acquired fetal images....

  14. Recent developments in multi-wire fixed abrasive slicing technique (FAST). [for low cost silicon wafer production from ingots

    Science.gov (United States)

    Schmid, F.; Khattak, C. P.; Smith, M. B.; Lynch, L. D.

    1982-01-01

    Slicing is an important processing step for all technologies based on the use of ingots. A comparison of the economics of three slicing techniques shows that the fixed abrasive slicing technique (FAST) is superior to the internal diameter (ID) and the multiblade slurry (MBS) techniques. Factors affecting contact length are discussed, taking into account kerf width, rocking angle, ingot size, and surface speed. Aspects of blade development are also considered. A high concentration of diamonds on wire has been obtained in wire packs usd for FAST slicing. The material removal rate was found to be directly proportional to the pressure at the diamond tips.

  15. A Unified Approach to Diffusion Direction Sensitive Slice Registration and 3-D DTI Reconstruction From Moving Fetal Brain Anatomy

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Seshamani, Sharmishtaa; Kroenke, Christopher

    2014-01-01

    to the underlying anatomy. Previous image registration techniques have been described to estimate the between slice fetal head motion, allowing the reconstruction of 3D a diffusion estimate on a regular grid using interpolation. We propose Approach to Unified Diffusion Sensitive Slice Alignment and Reconstruction...... (AUDiSSAR) that explicitly formulates a process for diffusion direction sensitive DW-slice-to-DTI-volume alignment. This also incorporates image resolution modeling to iteratively deconvolve the effects of the imaging point spread function using the multiple views provided by thick slices acquired...

  16. Multi-slice CT features of annular pancreas in neonates

    International Nuclear Information System (INIS)

    He Mingqing; Zhu Youzhi; Hu Kefei; Yin Chuangao; Hu Jun; Wang Song; Li Xu; Lu Zhongbin; Wang Yue; Liu Xiang

    2013-01-01

    Objective: To investigate the MSCT manifestations and their values in the diagnosis of annular pancreas in neonates. Methods: Retrospective analysis of clinical and CT findings in 27 cases with surgery-proved annular pancreas in neonates was made. The unenhanced and contrast-enhanced CT images were obtained in 20 patients. Two experienced radiologists determined the site and degree of obstruction, the relationship between the head of the pancreas and the obstruction point, and the surrounding tissue structure. Results: The direct signs included the fluid-filled or gas-filled bowel in the head of pancreas in 4 cases, the enhancement of surrounding soft tissue as enhanced pancreas in 17 cases, disappearance of the fat gap between the intestinal wall and the annular pancreas in 17 cases. The indirect signs included intestinal obstruction in 20 cases, 'single-bubble sign' in 2 cases, 'double-bubble sign' in 18 cases, the distal bowel without gas in 5 cases, small amount of gas in the distal bowel in 15 cases. In 12 of 18 cases showing 'double-bubble sign', the ratio of duodenal bubble diameter (Dd) to stomach bubble diameter (Ds)was over 1.0. The site of obstruction was located in the descending duodenum in 20 cases. The form of obstructed point presented with 'nipple sign' in 15 cases, with 'the mouse tail' in 5 cases. The expansion bowel was located in the head of pancreas in 1 case. Gas was found in the pancreatic duct in 1 case, and 'swirl sign' was shown in 2 cases. Conclusions: MSCT combined with three-dimensional reconstruction techniques can clearly demonstrate the annular pancreas' s shape, the site and degree of obstruction and other malformations. It can provide important information for clinical treatment. (authors)

  17. Teaching the physics of medical imaging: an active learning approach involving imaging of biological tissue

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pihl, Michael Johannes; Lonsdale, Markus Nowak

    2008-01-01

    Introduction to medical imaging is an experimentally oriented course in the physics of medical imaging, where the students record, process and analyse 3D data of an unknown piece of formalin fixed animal tissue embedded in agar in order to estimate the tissue types present. Planar X-ray, CT, MRI......, ultrasound and SPECT/PET images are recorded, showing the tissue in very different ways. In order for the students to estimate the tissue type, they need to study the physical principles of the imaging modalities. The “true” answer is subsequently revealed by slicing the tissue....

  18. Adaptation of Microplate-based Respirometry for Hippocampal Slices and Analysis of Respiratory Capacity

    Science.gov (United States)

    Schuh, Rosemary A.; Clerc, Pascaline; Hwang, Hyehyun; Mehrabian, Zara; Bittman, Kevin; Chen, Hegang; Polster, Brian M.

    2011-01-01

    Multiple neurodegenerative disorders are associated with altered mitochondrial bioenergetics. Although mitochondrial O2 consumption is frequently measured in isolated mitochondria, isolated synaptic nerve terminals (synaptosomes), or cultured cells, the absence of mature brain circuitry is a remaining limitation. Here we describe the development of a method that adapts the Seahorse Extracellular Flux Analyzer (XF24) for the microplate-based measurement of hippocampal slice O2 consumption. As a first evaluation of the technique, we compared whole slice bioenergetics to previous measurements made with synaptosomes or cultured neurons. We found that mitochondrial respiratory capacity and O2 consumption coupled to ATP synthesis could be estimated in cultured or acute hippocampal slices with preserved neural architecture. Mouse organotypic hippocampal slices oxidizing glucose displayed mitochondrial O2 consumption that was well-coupled, as determined by the sensitivity to the ATP synthase inhibitor oligomycin. However stimulation of respiration by uncoupler was modest (<120% of basal respiration) compared to previous measurements in cells or synaptosomes, although enhanced slightly (to ~150% of basal respiration) by the acute addition of the mitochondrial complex I-linked substrate pyruvate. These findings suggest a high basal utilization of respiratory capacity in slices and a limitation of glucose-derived substrate for maximal respiration. The improved throughput of microplate-based hippocampal respirometry over traditional O2 electrode-based methods is conducive to neuroprotective drug screening. When coupled with cell type-specific pharmacology or genetic manipulations, the ability to efficiently measure O2 consumption from whole slices should advance our understanding of mitochondrial roles in physiology and neuropathology. PMID:21520220

  19. Effects of Administration of Perinatal Bupropion on the Population Spike Amplitude in Neonatal Rat Hippocampal Slice

    Directory of Open Access Journals (Sweden)

    Soomaayeh Heysieat-talab

    2010-09-01

    Full Text Available Objective(sBupropion is an atypical antidepressant that is widely used in smoke cessation under FDA approval. The study of synaptic effects of bupropion can help to finding out its mechanism(s for stopping nicotine dependence. In this study the effects of perinatal bupropion on the population spike (PS amplitude of neonates were investigated. Materials and Methods Hippocampal slices were prepared from 18-25 days old rat pups. The experimental groups included control and bupropion-treated. Bupropion (40 mg/Kg, i.p. was applied daily in perinatal period as pre-treatment. Due to the studying acute effects, bupropion was also added to the perfusion medium (10, 50, 200 μM for 30 min. The evoked PS was recorded from pyramidal layer of CA1 area, following stimulation of Schaffer collaterals. ResultsA concentration of 10 μM bupropion had no significant effects on the PS amplitude. The 50 μM concentration of bupropion reduced the amplitude of responses in 50% of the studied cases. At a concentration of 200 μM, the recorded PS amplitudes were reduced in all slices (n= 22. Amplitude was completely abolished in 8 out of the 22 slices. The decrease of the PS amplitude was found to be more in the non-pre-treated slices than in the pre-treated slices when both were perfused with 200 μM bupropion.Conclusion The results showed the perinatal exposure to bupropion and its acute effects while indicating that at concentrations of 50 and 200 μM bupropion reduced the PS amplitude. It was also found that there was evidence of synaptic adaptation in comparison of bupropion-treated and non-treated slices whereas they were both perfused with 200 µM.

  20. Slicing Method for curved façade and window extraction from point clouds

    Science.gov (United States)

    Iman Zolanvari, S. M.; Laefer, Debra F.

    2016-09-01

    Laser scanning technology is a fast and reliable method to survey structures. However, the automatic conversion of such data into solid models for computation remains a major challenge, especially where non-rectilinear features are present. Since, openings and the overall dimensions of the buildings are the most critical elements in computational models for structural analysis, this article introduces the Slicing Method as a new, computationally-efficient method for extracting overall façade and window boundary points for reconstructing a façade into a geometry compatible for computational modelling. After finding a principal plane, the technique slices a façade into limited portions, with each slice representing a unique, imaginary section passing through a building. This is done along a façade's principal axes to segregate window and door openings from structural portions of the load-bearing masonry walls. The method detects each opening area's boundaries, as well as the overall boundary of the façade, in part, by using a one-dimensional projection to accelerate processing. Slices were optimised as 14.3 slices per vertical metre of building and 25 slices per horizontal metre of building, irrespective of building configuration or complexity. The proposed procedure was validated by its application to three highly decorative, historic brick buildings. Accuracy in excess of 93% was achieved with no manual intervention on highly complex buildings and nearly 100% on simple ones. Furthermore, computational times were less than 3 sec for data sets up to 2.6 million points, while similar existing approaches required more than 16 hr for such datasets.

  1. A simple water-immersion condenser for imaging living brain slices on an inverted microscope.

    Science.gov (United States)

    Prusky, G T

    1997-09-05

    Due to some physical limitations of conventional condensers, inverted compound microscopes are not optimally suited for imaging living brain slices with transmitted light. Herein is described a simple device that converts an inverted microscope into an effective tool for this application by utilizing an objective as a condenser. The device is mounted on a microscope in place of the condenser, is threaded to accept a water immersion objective, and has a slot for a differential interference contrast (DIC) slider. When combined with infrared video techniques, this device allows an inverted microscope to effectively image living cells within thick brain slices in an open perfusion chamber.

  2. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    International Nuclear Information System (INIS)

    Tanaka, Hiroshi

    1988-01-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development. (author)

  3. Usefulness of thin slice target CT scan in detecting mediastinal and hilar lymphadenopathy

    International Nuclear Information System (INIS)

    Yoshida, Shoji; Maeda, Tomoho; Nishioka, Masatoshi

    1986-01-01

    Comparative study of target scan with the different slice thickness and scan modes was performed to evaluate the mediastinal and hilar lymphadenopathy. 20 cases in controls and 35 cases in lymphadenopathy were examined. To delineate mediastinal and hilar lymphadenopathy, the scan mode of standard target was most useful in contrast and sharpness. Thin slice thickness with 5 mm was necessary in detecting small lymphnode or contour and internal structure of enlarged lymphnode. Valuable estimation of 5 mm contiguous target scan was obtained in the subaortic node (no. 5), tracheobronchial node (no. 4), precarinal and subcarinal node (no. 7) and right hilar node (no. 12). (author)

  4. Time-space modal logic for verification of bit-slice circuits

    Science.gov (United States)

    Hiraishi, Hiromi

    1996-03-01

    The major goal of this paper is to propose a new modal logic aiming at formal verification of bit-slice circuits. The new logic is called as time-space modal logic and its major feature is that it can handle two transition relations: one for time transition and the other for space transition. As for a verification algorithm, a symbolic model checking algorithm of the new logic is shown. This could be applicable to verification of bit-slice microprocessor of infinite bit width and 1D systolic array of infinite length. A simple benchmark result shows the effectiveness of the proposed approach.

  5. PICTURE, 2-D Slices Through 3-D CG of MORSE, QAD-CG

    International Nuclear Information System (INIS)

    1994-01-01

    1 - Description of program or function: Picture generates plots of two-dimensional slices through the three-dimensional geometry described by the combinatorial geometry (CG) package used in such codes as MORSE and QAD-CG. These plots are printed on a standard line printer. 2 - Method of solution: Several different ways are available to obtain a two-dimensional slice through the geometry. The geometry ray tracing capability is tested by forcing the geometry package to execute the routines and logic of the Monte Carlo random walk or kernel integration algorithms. 3 - Restrictions on the complexity of the problem: None tested besides those listed in the input descriptions

  6. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    International Nuclear Information System (INIS)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta

    1992-01-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author)

  7. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiroshi

    1988-07-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development.

  8. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1992-06-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author).

  9. Dopaminergic differentiation of human neural stem cells mediated by co-cultured rat striatal brain slices

    DEFF Research Database (Denmark)

    Anwar, Mohammad Raffaqat; Andreasen, Christian Maaløv; Lippert, Solvej Kølvraa

    2008-01-01

    differentiation, we co-cultured cells from a human neural forebrain-derived stem cell line (hNS1) with rat striatal brain slices. In brief, coronal slices of neonatal rat striatum were cultured on semiporous membrane inserts placed in six-well trays overlying monolayers of hNS1 cells. After 12 days of co......Properly committed neural stem cells constitute a promising source of cells for transplantation in Parkinson's disease, but a protocol for controlled dopaminergic differentiation is not yet available. To establish a setting for identification of secreted neural compounds promoting dopaminergic...

  10. GDNF and neublastin protect against NMDA-induced excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Bonde, C; Kristensen, B W; Blaabjerg, M

    2000-01-01

    -producing HiB5 cells, were added to slice cultures I h before exposure to 10 microM NMDA for 48h. Neuronal cell death was monitored, before and during the NMDA exposure, by densitometric measurements of propidium iodide (PI) uptake and loss of Nissl staining. Both the addition of rhGDNF and NBN......The potential neuroprotective effects of glial cell line-derived neurotrophic factor (GDNF) and neublastin (NBN) against NMDA-induced excitotoxicity were examined in hippocampal brain slice cultures. Recombinant human GDNF (25-100 ng/ ml) or NBN, in medium conditioned by growth of transfected, NBN...

  11. Mechanisms contributing to cluster formation in the inferior olivary nucleus in brainstem slices from postnatal mice

    DEFF Research Database (Denmark)

    Kølvraa, Mathias; Müller, Felix C; Jahnsen, Henrik

    2014-01-01

    The inferior olivary nucleus (IO) in in vitro slices from postnatal mice (P5.5-P15.5) spontaneously generates clusters of neurons with synchronous calcium transients, and intracellular recordings from IO neurons suggest that electrical coupling between neighbouring IO neurons may serve as a synch......The inferior olivary nucleus (IO) in in vitro slices from postnatal mice (P5.5-P15.5) spontaneously generates clusters of neurons with synchronous calcium transients, and intracellular recordings from IO neurons suggest that electrical coupling between neighbouring IO neurons may serve...

  12. Live cell imaging of cytosolic NADH/NAD+ ratio in hepatocytes and liver slices.

    Science.gov (United States)

    Masia, Ricard; McCarty, William J; Lahmann, Carolina; Luther, Jay; Chung, Raymond T; Yarmush, Martin L; Yellen, Gary

    2018-01-01

    Fatty liver disease (FLD), the most common chronic liver disease in the United States, may be caused by alcohol or the metabolic syndrome. Alcohol is oxidized in the cytosol of hepatocytes by alcohol dehydrogenase (ADH), which generates NADH and increases cytosolic NADH/NAD + ratio. The increased ratio may be important for development of FLD, but our ability to examine this question is hindered by methodological limitations. To address this, we used the genetically encoded fluorescent sensor Peredox to obtain dynamic, real-time measurements of cytosolic NADH/NAD + ratio in living hepatocytes. Peredox was expressed in dissociated rat hepatocytes and HepG2 cells by transfection, and in mouse liver slices by tail-vein injection of adeno-associated virus (AAV)-encoded sensor. Under control conditions, hepatocytes and liver slices exhibit a relatively low (oxidized) cytosolic NADH/NAD + ratio as reported by Peredox. The ratio responds rapidly and reversibly to substrates of lactate dehydrogenase (LDH) and sorbitol dehydrogenase (SDH). Ethanol causes a robust dose-dependent increase in cytosolic NADH/NAD + ratio, and this increase is mitigated by the presence of NAD + -generating substrates of LDH or SDH. In contrast to hepatocytes and slices, HepG2 cells exhibit a relatively high (reduced) ratio and show minimal responses to substrates of ADH and SDH. In slices, we show that comparable results are obtained with epifluorescence imaging and two-photon fluorescence lifetime imaging (2p-FLIM). Live cell imaging with Peredox is a promising new approach to investigate cytosolic NADH/NAD + ratio in hepatocytes. Imaging in liver slices is particularly attractive because it allows preservation of liver microanatomy and metabolic zonation of hepatocytes. NEW & NOTEWORTHY We describe and validate a new approach for measuring free cytosolic NADH/NAD + ratio in hepatocytes and liver slices: live cell imaging with the fluorescent biosensor Peredox. This approach yields dynamic, real

  13. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  14. The reliability of a segmentation methodology for assessing intramuscular adipose tissue and other soft-tissue compartments of lower leg MRI images.

    Science.gov (United States)

    Karampatos, Sarah; Papaioannou, Alexandra; Beattie, Karen A; Maly, Monica R; Chan, Adrian; Adachi, Jonathan D; Pritchard, Janet M

    2016-04-01

    Determine the reliability of a magnetic resonance (MR) image segmentation protocol for quantifying intramuscular adipose tissue (IntraMAT), subcutaneous adipose tissue, total muscle and intermuscular adipose tissue (InterMAT) of the lower leg. Ten axial lower leg MRI slices were obtained from 21 postmenopausal women using a 1 Tesla peripheral MRI system. Images were analyzed using sliceOmatic™ software. The average cross-sectional areas of the tissues were computed for the ten slices. Intra-rater and inter-rater reliability were determined and expressed as the standard error of measurement (SEM) (absolute reliability) and intraclass coefficient (ICC) (relative reliability). Intra-rater and inter-rater reliability for IntraMAT were 0.991 (95% confidence interval [CI] 0.978-0.996, p soft tissue compartments, the ICCs were all >0.90 (p soft-tissue compartments of the lower leg. A standard operating procedure manual is provided to assist users, and SEM values can be used to estimate sample size and determine confidence in repeated measurements in future research.

  15. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  16. Does slice thickness affect diagnostic performance of 64-slice CT coronary angiography in stable and unstable angina patients with a positive calcium score?

    Energy Technology Data Exchange (ETDEWEB)

    Meijs, Matthijs F.L.; Vos, Alexander M. de; Cramer, Maarten J.; Doevendans, Pieter A.; Vries, Jan J.J. de; Rutten, Annemarieke; Budde, Ricardo P.J.; Prokop, Mathias (Dept. of Radiology, Univ. Medical Center Utrecht, Utrecht (Netherlands)), e-mail: m.meijs@umcutrecht.nl; Meijboom, W. Bob; Feyter, Pim J. de (Dept. of Cardiology, Erasmus Medical Center, Rotterdam (Netherlands))

    2010-05-15

    Background: Coronary calcification can lead to over-estimation of the degree of coronary stenosis. Purpose: To evaluate whether thinner reconstruction thickness improves the diagnostic performance of 64-slice CT coronary angiography (CTCA) in angina patients with a positive calcium score. Material and Methods: We selected 20 scans from a clinical study comparing CTCA to conventional coronary angiography (CCA) in stable and unstable angina patients based on a low number of motion artifacts and a positive calcium score. All images were acquired at 64 x 0.625 mm and each CTCA scan was reconstructed at slice thickness/increment 0.67 mm/0.33 mm, 0.9 mm/0.45 mm, and 1.4 mm/0.7 mm. Two reviewers blinded for CCA results independently evaluated the scans for the presence of significant coronary artery disease (CAD) in three randomly composed series, with =2 weeks in between series. The diagnostic performance of CTCA was compared for the different slice thicknesses using a pooled analysis of both reviewers. Significant CAD was defined as >50% diameter narrowing on quantitative CCA. Image noise (standard deviation of CT numbers) was measured in all scans. Inter-observer variability was assessed with kappa. Results: Significant CAD was present in 8% of 304 available segments. Median total Agatston calcium score was 181.8 (interquartile range 34.9-815.6). Sensitivity at 0.67 mm, 0.9 mm, and 1.4 mm slice thickness was 70% (95% confidence interval 57-83%), 74% (62-86%), and 70% (57-83%), respectively. Specificity was 85% (82-88%), 84% (81-87%), and 84% (81-87%), respectively. The positive predictive value was 30 (21-38%), 29 (21-37%), and 28 (20-36%), respectively. The negative predictive value was 97% (95-98%), 97% (96-99%), and 97% (96-99%), respectively. Kappa for inter-observer agreement was 0.56, 0.58, and 0.59. Noise decreased from 32.9 HU at 0.67 mm, to 23.2 HU at 1.4 mm (P<0.001). Conclusion: Diagnostic performance of CTCA in angina patients with a positive calcium score

  17. Up-regulation of cytochrome P450 and phase II enzyme systems in rat precision-cut rat lung slices by the intact glucosinolates, glucoraphanin and glucoerucin.

    Science.gov (United States)

    Abdull Razis, Ahmad Faizal; Bagatta, Manuela; De Nicola, Gina Rosalinda; Iori, Renato; Ioannides, Costas

    2011-03-01

    It is believed that the chemopreventive activity of cruciferous vegetables in the lung and other tissues is exclusively the result of exposure to degradation products of glucosinolates, such as the isothiocyanates, and that the parent glucosinolates make no contribution. In the present study, evidence is presented for the first time that, in rat lung, the intact glucosinolates, glucoraphanin and glucoerucin, can modulate carcinogen-metabolising enzyme systems. The glucosinolates were isolated from cruciferous vegetables and incubated (1-25 μM) with precision-cut rat lung slices for 24h. Both glucosinolates, at concentrations as low as 1 μM, up-regulated the O-deethylation of ethoxyresorufin and the apoprotein levels of CYP1A1 and CYP1B1; supplementation of the incubation medium with myrosinase, the enzyme that converts glucosinolates to their corresponding isothiocyanates, abolished the rise in ethoxyresorufin O-deethylase activity. In contrast, neither glucosinolate, at the concentrations studied, influenced quinone reductase activity in the lung slices, but addition of myrosinase to the glucosinolate incubations led to a marked rise in activity. Glutathione S-transferase activity, monitored using 1-chloro-2,4-dinitrobenzene as the accepting substrate, was elevated in lung slices exposed to glucoraphanin. GSTα protein levels were increased by glucoraphanin and, to a much lesser extent, glucoerucin. It may be concluded that intact glucosinolates can modulate the activity of pulmonary carcinogen-metabolising enzyme systems, and can thus contribute to the documented chemopreventive activity of cruciferous vegetables in the lung. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Non-genomic action of beclomethasone dipropionate on bronchoconstriction caused by leukotriene C4 in precision cut lung slices in the horse

    Directory of Open Access Journals (Sweden)

    Fugazzola Maria

    2012-09-01

    Full Text Available Abstract Background Glucocorticoids have been proven to be effective in the therapy of recurrent airway obstruction (RAO in horses via systemic as well as local (inhalative administration. Elective analysis of the effects of this drug on bronchoconstriction in viable lung tissue offers an insight into the mechanism of action of the inflammatory cascade occurring during RAO which is still unclear. The mechanism of action of steroids in treatment of RAO is thought to be induced through classical genomic pathways. We aimed at electively studying the effects of the glucocorticoid beclomethasone dipropionate on equine precision-cut lung slices (PCLS. PCLS were used to analyze ex-vivo effects of beclomethasone on inhibiting bronchoconstriction in the horse. The inhibiting effect was measured through instillation of a known mediator of inflammation and bronchoconstriction, leukotriene C4. For this, the accessory lobes of 13 horses subjected to euthanasia for reasons unrelated to the respiratory apparatus were used to obtain viable lung slices. Results After 30 minutes of PCLS incubation, beclomethasone showed to significantly inhibit the contraction of the bronchioles after instillation with leukotriene C4. The EC50 values of the two contraction curves (LTC4 with and without BDP differed significantly from each other (p = 0.002. The possibility of a non-genomic rapid mechanism of action seems likely since transcriptional activities require a longer lag period. Conclusions In human neuroendocrinology, high levels of glucocorticoids have been proven to function via a non-genomic mechanism of membrane receptors. The concentration of beclomethasone used on the lung slices in our study can be considered as high. This allows speculation about similar rapid non-genomic mechanisms of high-dosage inhaled glucocorticoids in the lower airways of horses. However, further assessment on a molecular basis is needed to confirm this.

  19. Study on tissue culture for Gelidium seedling

    Science.gov (United States)

    Pei, Lu-Qing; Luo, Qi-Jun; Fei, Zhi-Qing; Ma, Bin

    1996-06-01

    As seedling culture is a crucial factor for successful cultivation of Gelidium, the authors researched tissue culture technology for producing seedlings. The morphogeny and experimental ecology were observed and studied fully in 2 5 mm isolated tissue fragments. Regeneration, appearance of branching creepers and attaching structure and new erect seedlings production and development were studied. Fragments were sown on bamboo slice and vinylon rope. The seedlings were cultured 20 30 days indoor, then cultured in the sea, where the density of erect seedlings was 3 19 seedlings/cm2, growth rate was 3.84% day. The frond arising from seedlings directly was up to 10 cm per year. The ecological conditions for regenerated seedlings are similar to the natural ones. The regenerated seedlings are suitable for raft culture in various sea areas.

  20. Atorvastatin and Fluoxetine Prevent Oxidative Stress and Mitochondrial Dysfunction Evoked by Glutamate Toxicity in Hippocampal Slices.

    Science.gov (United States)

    Ludka, Fabiana K; Dal-Cim, Tharine; Binder, Luisa Bandeira; Constantino, Leandra Celso; Massari, Caio; Tasca, Carla I

    2017-07-01

    Atorvastatin has been shown to exert a neuroprotective action by counteracting glutamatergic toxicity. Recently, we have shown atorvastatin also exerts an antidepressant-like effect that depends on both glutamatergic and serotonergic systems modulation. Excitotoxicity is involved in several brain disorders including depression; thus, it is suggested that antidepressants may target glutamatergic system as a final common pathway. In this study, a comparison of the mechanisms involved in the putative neuroprotective effect of a repetitive atorvastatin or fluoxetine treatment against glutamate toxicity in hippocampal slices was performed. Adult Swiss mice were treated with atorvastatin (10 mg/kg, p.o.) or fluoxetine (10 mg/kg, p.o.), once a day during seven consecutive days. On the eighth day, animals were killed and hippocampal slices were obtained and subjected to an in vitro protocol of glutamate toxicity. An acute treatment of atorvastatin or fluoxetine was not neuroprotective; however, the repeated atorvastatin or fluoxetine treatment prevented the decrease in cellular viability induced by glutamate in hippocampal slices. The loss of cellular viability induced by glutamate was accompanied by increased D-aspartate release, increased reactive oxygen species (ROS) and nitric oxide (NO) production, and impaired mitochondrial membrane potential. Atorvastatin or fluoxetine repeated treatment also presented an antidepressant-like effect in the tail suspension test. Atorvastatin or fluoxetine treatment was effective in protecting mice hippocampal slices from glutamate toxicity by preventing the oxidative stress and mitochondrial dysfunction.