WorldWideScience

Sample records for tissue biopsy samples

  1. Mantle biopsy: a technique for nondestructive tissue-sampling of freshwater mussels

    Science.gov (United States)

    David J. Berg; Wendell R. Haag; Sheldon I. Guttman; James B. Sickel

    1995-01-01

    Mantle biopsy is a means of obtaining tissue samples for genetic, physiological, and contaminant studies of bivalves; but the effects of this biopsy on survival have not been determined. We describe a simple technique for obtaining such samples from unionacean bivalves and how we compared survival among biopsied and control organisms in field experiments. Survival was...

  2. Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography

    International Nuclear Information System (INIS)

    Shini, Mohanad; Rubinsky, Boris

    2008-01-01

    Biopsies are a reliable method for examining tissues and organs inside the body, in particular for detection of tumors. However, a single biopsy produces only limited information on the site from which it is taken. Therefore, tumor detection now employs multiple biopsy samplings to examine larger volumes of tissue. Nevertheless, even with multiple biopsies, the information remains discrete, while the costs of biopsy increase. Here we propose and evaluate the feasibility of using minimally invasive medical imaging as a means to overcome the limitations of discrete biopsy sampling. The minimally invasive medical imaging technique employs the biopsy probe as electrodes for measurements of electrical impedance tomography relevant data during each biopsy sampling. The data from multiple samplings are combined and used to produce an EIT image of the tissue. Two- and three-dimensional mathematical simulations confirm that the minimally invasive medical imaging technique can produce electrical impedance tomography images of the tissues between the biopsy probe insertion sites. We show that these images can detect tumors that would be missed with multiple biopsy samplings only, and that the technique may facilitate the detection of tumors with fewer biopsies, thereby reducing the cost of cancer detection

  3. High-resolution, 2- and 3-dimensional imaging of uncut, unembedded tissue biopsy samples.

    Science.gov (United States)

    Torres, Richard; Vesuna, Sam; Levene, Michael J

    2014-03-01

    Despite continuing advances in tissue processing automation, traditional embedding, cutting, and staining methods limit our ability for rapid, comprehensive visual examination. These limitations are particularly relevant to biopsies for which immediate therapeutic decisions are most necessary, faster feedback to the patient is desired, and preservation of tissue for ancillary studies is most important. The recent development of improved tissue clearing techniques has made it possible to consider use of multiphoton microscopy (MPM) tools in clinical settings, which could address difficulties of established methods. To demonstrate the potential of MPM of cleared tissue for the evaluation of unembedded and uncut pathology samples. Human prostate, liver, breast, and kidney specimens were fixed and dehydrated by using traditional histologic techniques, with or without incorporation of nucleic acid fluorescent stains into dehydration steps. A benzyl alcohol/benzyl benzoate clearing protocol was substituted for xylene. Multiphoton microscopy was performed on a home-built system. Excellent morphologic detail was achievable with MPM at depths greater than 500 μm. Pseudocoloring produced images analogous to hematoxylin-eosin-stained images. Concurrent second-harmonic generation detection allowed mapping of collagen. Subsequent traditional section staining with hematoxylin-eosin did not reveal any detrimental morphologic effects. Sample immunostains on renal tissue showed preservation of normal reactivity. Complete reconstructions of 1-mm cubic samples elucidated 3-dimensional architectural organization. Multiphoton microscopy on cleared, unembedded, uncut biopsy specimens shows potential as a practical clinical tool with significant advantages over traditional histology while maintaining compatibility with gold standard techniques. Further investigation to address remaining implementation barriers is warranted.

  4. Sugar and acid interconversion in tomato fruits based on biopsy sampling of locule gel and pericarp tissue

    NARCIS (Netherlands)

    Schouten, R.E.; Woltering, E.J.; Tijskens, L.M.M.

    2016-01-01

    This study deals with quantifying sugar and acids levels important for the perceived taste of tomatoes (Solanum lycopersicum). Sugar and acids levels were measured repeatedly on the same tomato using tissue samples obtained with a biopsy needle in combination with HPLC protocols. Biopsies of

  5. Determination of Magnesium in Needle Biopsy Samples of Muscle Tissue by Means of Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D; Sjoeberg, H E

    1964-07-15

    Magnesium has been determined by means of neutron-activation analysis in needle biopsy samples of the order of magnitude 1 mg dry weight. The procedure applied was to extract the Mg-27 activity from irradiated muscle tissue with concentrated hydrochloric acid followed by a fast hydroxide precipitation and gamma-spectrometric measurements. The Mg activity was recovered in the muscle tissue samples to (97 {+-} 2) per cent. The sensitivity for the magnesium determination is estimated as 0.3 {mu}g.

  6. Hepatic mitochondrial function analysis using needle liver biopsy samples.

    Directory of Open Access Journals (Sweden)

    Michael J J Chu

    Full Text Available BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS: An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS: The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean. Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each showed low coefficient of variation (<10% in measurements of State-III respiration, electron transport chain (ETC capacity and respiratory control ratio (RCR. Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION: Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.

  7. 1300 nm and 890 nm OCT images of oral cancer tissue engineered models and biopsy samples offer complimentary performance (Conference Presentation)

    Science.gov (United States)

    Boadi, Joseph; Byers, Robert A.; Fernandes, Jon; Mittar, Shweta; Hearnden, Vanessa; Lu, Zenghai; MacNeil, Sheila; Thornhill, Martin; Murdoch, Craig; Hunter, Keith D.; McKechnie, Alasdair; Matcher, Stephen J.

    2016-02-01

    OCT has demonstrated great potential to non-invasively detect oral epithelial cancers, potentially guiding biopsy and surgical resection. On non-ophthalmic tissues the preferred illumination wavelength is 1300 nm. Previous studies on skin have shown that useful image data can also be obtained at shorter wavelengths, with systems at 1060 nm and 820 nm offering reduced depth penetration but higher contrast. Here we apply a similar comparison to tissue engineered models of oral cancer and also to human biopsy samples, generally finding a similar trend. 1300 nm multi-beam OCT (Michelson Diagnostics EX1301) visualises stromal structures and surface keratin more clearly, providing useful image contrast down to around 1 mm. This system was compared with an ultra-high resolution home-built system operating at 890 nm (2.5 micron resolution vs 7.5 micron axial resolution for the EX1301). The UHR system reveals epithelial features more clearly, especially in the DOK pre-invasive cell line model and the biopsy samples. The relative effects of center wavelength vs axial resolution in generating the differential, wavelength-dependent contrast are assessed and the OCT biopsy images are compared with contemporary histology.

  8. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  9. Proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xing [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China); Xu, Yanli [Fuyang People’s Hospital (China); Meng, Qian [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China); Zheng, Qingqing [Digestive Endoscopic Center, Shanghai Jiaotong University Affiliated Sixth People’s Hospital (China); Wu, Jianhong [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China); Wang, Chen; Jia, Weiping [Shanghai Key Laboratory of Diabetes Mellitus, Department of Endocrinology and Metabolism, Shanghai Diabetes Institute, Shanghai Clinical Center for Diabetes, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital (China); Figeys, Daniel [Department of Biochemistry, Microbiology and Immunology, and Department of Chemistry and Biomolecular Sciences, University of Ottawa (Canada); Chang, Ying, E-mail: emulan@163.com [Digestive Endoscopic Center, Shanghai Jiaotong University Affiliated Sixth People’s Hospital (China); Zhou, Hu, E-mail: zhouhu@simm.ac.cn [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China)

    2016-08-05

    Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP and NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.

  10. Proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling

    International Nuclear Information System (INIS)

    Liu, Xing; Xu, Yanli; Meng, Qian; Zheng, Qingqing; Wu, Jianhong; Wang, Chen; Jia, Weiping; Figeys, Daniel; Chang, Ying; Zhou, Hu

    2016-01-01

    Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP and NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.

  11. Identification of proteomic biomarkers predicting prostate cancer aggressiveness and lethality despite biopsy-sampling error.

    Science.gov (United States)

    Shipitsin, M; Small, C; Choudhury, S; Giladi, E; Friedlander, S; Nardone, J; Hussain, S; Hurley, A D; Ernst, C; Huang, Y E; Chang, H; Nifong, T P; Rimm, D L; Dunyak, J; Loda, M; Berman, D M; Blume-Jensen, P

    2014-09-09

    Key challenges of biopsy-based determination of prostate cancer aggressiveness include tumour heterogeneity, biopsy-sampling error, and variations in biopsy interpretation. The resulting uncertainty in risk assessment leads to significant overtreatment, with associated costs and morbidity. We developed a performance-based strategy to identify protein biomarkers predictive of prostate cancer aggressiveness and lethality regardless of biopsy-sampling variation. Prostatectomy samples from a large patient cohort with long follow-up were blindly assessed by expert pathologists who identified the tissue regions with the highest and lowest Gleason grade from each patient. To simulate biopsy-sampling error, a core from a high- and a low-Gleason area from each patient sample was used to generate a 'high' and a 'low' tumour microarray, respectively. Using a quantitative proteomics approach, we identified from 160 candidates 12 biomarkers that predicted prostate cancer aggressiveness (surgical Gleason and TNM stage) and lethal outcome robustly in both high- and low-Gleason areas. Conversely, a previously reported lethal outcome-predictive marker signature for prostatectomy tissue was unable to perform under circumstances of maximal sampling error. Our results have important implications for cancer biomarker discovery in general and development of a sampling error-resistant clinical biopsy test for prediction of prostate cancer aggressiveness.

  12. High velocity pulse biopsy device enables controllable and precise needle insertion and high yield tissue acquisition.

    Science.gov (United States)

    Schässburger, Kai-Uwe; Paepke, Stefan; Saracco, Ariel; Azavedo, Edward; Ekström, Christina; Wiksell, Hans

    2018-02-01

    Minimally invasive biopsies are a cornerstone of breast cancer management with ultrasound being the preferred guidance modality. New developments in breast cancer management and advances in imaging technologies bring new challenges to current biopsy methodologies. A new biopsy device (NeoNavia® biopsy system, 14 G) was developed. It incorporates a pneumatic needle insertion mechanism that is intended to provide better control of needle progression and enable stepwise insertion without noticeable deformation or displacement of surrounding tissue as visualized under ultrasound. A new method of tissue acquisition was designed to achieve a sampling yield higher than standard methodologies. Needle dynamics was assessed on a specifically designed test bed and sampling performance was compared to a Magnum® biopsy instrument (Bard, Covington, GA, USA) in representative tissue models. The histological quality of samples obtained ex-vivo was evaluated. A pneumatic pulse was measured to accelerate the needle to a maximum velocity of 21.2 ± 2.5 m/s on a stroke length of 2.5 mm, achieving significantly higher acceleration, maximum velocity and power than current biopsy devices. Mean weight of samples obtained by the NeoNavia device were 3.5, 4.6, and 4.3 times higher when sampling was performed in turkey breast, calf thymus and swine pancreas, respectively, as compared to samples obtained with the Magnum instrument. Ex-vivo analysis indicates that the method of tissue acquisition has no apparent negative impact on the histopathologic quality of obtained samples. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Technical note: The development of a methodology for ruminal and colon tissue biopsying of young Holstein dairy calves.

    Science.gov (United States)

    van Niekerk, J K; Middeldorp, M; Steele, M A

    2018-05-09

    The objectives of this study were to develop a methodology for biopsying the rumen and colon of young dairy calves and to collect suitable quality tissue samples for microscopic and gene expression analysis. Six Holstein dairy bull calves (45.0 ± 1.5 kg birth weight) were ruminally cannulated during the second week of life and weaned at the end of wk 6. Ruminal and colon tissue samples were collected at the end of wk 5, 6, 7, 8, and 12. Calves were not sedated but were restrained in a chute for sampling. The endoscope (100 cm length, 9.8 mm diameter) was introduced through the rumen cannula to harvest ruminal tissue. Endoscopic biopsies of the rumen with endoscopic biopsy forceps were unsuccessful 85% of the time because they were unable to shear the ruminal tissue. Thereafter, an Allis clamp was used to retrieve the blind sac through the rumen cannula to perform direct tissue biopsying with surgical scissors. To biopsy the colon, the lubricated distal tip of an endoscope was slowly inserted into the calf's anus. A total of 6 colon tissue samples (12.6 ± 0.74 mg) were collected per calf per time point from the distal colon 30 to 40 cm from the calf's anus using endoscopic biopsy forceps, which were inserted through the instrument channel. A new forcep was used between sites and calves. Between calves, the outside of the endoscope was washed with 4% chlorohexidine and rinsed with water and the instrument channel was washed with distilled water and 70% ethanol. Colon and ruminal samples were processed for histological measurements, and RNA was isolated and sequenced. High-quality RNA (RNA integrity number 8.8 ± 0.08) was collected from samples, and light and electron microscopy was performed on samples. In conclusion, endoscopic biopsying can be used for tissue harvest in the colon of young calves. However, it was found that collecting ruminal tissue by retracting the rumen from the cannula and taking samples with surgical scissors was more successful than an

  14. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  15. Optical biopsy of tissue with Mueller polarimetry: theory and experiments (Conference Presentation)

    Science.gov (United States)

    Novikova, Tatiana; Meglinski, Igor; Garcia-Caurel, Enric; Bykov, Alexander; Rehbinder, Jean; Deby, Stanislas; Vizet, Jérémy; Pierangelo, Angelo; Moreau, François; Validire, Pierre; Benali, Abdelali; Gayet, Brice; Teig, Benjamin; Nazac, André; Ossikovski, Razvigor

    2017-02-01

    The rise of optical biopsy as an alternative to classical biopsy is dictated by ongoing technological progress: any type of measurements has to be fast, precise, non-invasive and implemented in-vivo. The use of polarized light for optical biopsy has a long history. As Mueller-Stokes formalism provides the most complete description of polarized light interaction with any type of sample (even depolarizing one) we explored the capabilities of in-house multi-wavelength Mueller imaging polarimeter for the detection of pre-malignancy and malignancy. Our studies were performed with both scattering phantom tissues (in transmission configuration) and specimens of human colon and uterine cervix (in backscattering configuration). For the interpretation of measurement results we decomposed Mueller matrix of a sample into product of elementary Mueller matrices of homogeneous diattenuator, retarder, and depolarizer. This phenomenological approach does not require the exact solution of Maxwell equations and provides the "effective" values of polarimetric properties of sample. Exploring differential Mueller matrix formalism for fluctuating medium we showed that depolarization in homogeneous turbid medium varied parabolically with the pathlength of transmitted light, while the standard deviation of elementary polarization properties of medium depends linearly on the concentration of scatterers. Neither scattering phantoms nor human tissue possessed any measurable diattenuation in backscattering configuration. The polarimetric images of tissue depolarization power, scalar birefringence and orientation of optical axis were compared with the analysis of histological slides. The spectral dependence of depolarization power and scalar birefringence values ascertained the potential of imaging Mueller polarimetry to discriminate healthy and diseased tissue zones.

  16. A tissue biopsy-based epigenetic multiplex PCR assay for prostate cancer detection

    Directory of Open Access Journals (Sweden)

    Van Neste Leander

    2012-06-01

    Full Text Available Abstract Background PSA-directed prostate cancer screening leads to a high rate of false positive identifications and an unnecessary biopsy burden. Epigenetic biomarkers have proven useful, exhibiting frequent and abundant inactivation of tumor suppressor genes through such mechanisms. An epigenetic, multiplex PCR test for prostate cancer diagnosis could provide physicians with better tools to help their patients. Biomarkers like GSTP1, APC and RASSF1 have demonstrated involvement with prostate cancer, with the latter two genes playing prominent roles in the field effect. The epigenetic states of these genes can be used to assess the likelihood of cancer presence or absence. Results An initial test cohort of 30 prostate cancer-positive samples and 12 cancer-negative samples was used as basis for the development and optimization of an epigenetic multiplex assay based on the GSTP1, APC and RASSF1 genes, using methylation specific PCR (MSP. The effect of prostate needle core biopsy sample volume and age of formalin-fixed paraffin-embedded (FFPE samples was evaluated on an independent follow-up cohort of 51 cancer-positive patients. Multiplexing affects copy number calculations in a consistent way per assay. Methylation ratios are therefore altered compared to the respective singleplex assays, but the correlation with patient outcome remains equivalent. In addition, tissue-biopsy samples as small as 20 μm can be used to detect methylation in a reliable manner. The age of FFPE-samples does have a negative impact on DNA quality and quantity. Conclusions The developed multiplex assay appears functionally similar to individual singleplex assays, with the benefit of lower tissue requirements, lower cost and decreased signal variation. This assay can be applied to small biopsy specimens, down to 20 microns, widening clinical applicability. Increasing the sample volume can compensate the loss of DNA quality and quantity in older samples.

  17. Combined spectroscopic imaging and chemometric approach for automatically partitioning tissue types in human prostate tissue biopsies

    Science.gov (United States)

    Haka, Abigail S.; Kidder, Linda H.; Lewis, E. Neil

    2001-07-01

    We have applied Fourier transform infrared (FTIR) spectroscopic imaging, coupling a mercury cadmium telluride (MCT) focal plane array detector (FPA) and a Michelson step scan interferometer, to the investigation of various states of malignant human prostate tissue. The MCT FPA used consists of 64x64 pixels, each 61 micrometers 2, and has a spectral range of 2-10.5 microns. Each imaging data set was collected at 16-1 resolution, resulting in 512 image planes and a total of 4096 interferograms. In this article we describe a method for separating different tissue types contained within FTIR spectroscopic imaging data sets of human prostate tissue biopsies. We present images, generated by the Fuzzy C-Means clustering algorithm, which demonstrate the successful partitioning of distinct tissue type domains. Additionally, analysis of differences in the centroid spectra corresponding to different tissue types provides an insight into their biochemical composition. Lastly, we demonstrate the ability to partition tissue type regions in a different data set using centroid spectra calculated from the original data set. This has implications for the use of the Fuzzy C-Means algorithm as an automated technique for the separation and examination of tissue domains in biopsy samples.

  18. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  19. Gastric tissue biopsy and culture

    Science.gov (United States)

    ... symptoms may include: Loss of appetite or weight loss Nausea and vomiting Pain in the upper part of the belly Black stools Vomiting blood or coffee ground-like material A gastric tissue biopsy and culture can help detect: Cancer Infections, most commonly Helicobacter ...

  20. A practical guideline to remote biopsy darting of wildebeests for genetic sampling

    Directory of Open Access Journals (Sweden)

    Domnic Mijele

    2016-12-01

    Full Text Available The use of biopsy darts for remote collection of tissue samples from free-ranging terrestrial and aquatic animal species has gained popularity in the recent past. The success of darting is very important since scientists may not have many chances to re-dart the same animal, especially with the free-ranging elusive wildlife species. We used wildebeest (Connochaetes taurinus as a model to estimate the optimum shooting distance, pressure and the shot part of the body through which a researcher can optimize the success and amount of tissue collected from similar wild land mammalian species. Wildebeests were darted at six categories of distances ranging between 10 and 45 m and dart gun pressures of 5–14 millibar. The number of failed darts increased by increasing the darting distance: 0% (10 m, 0% (20 m, 6% (30 m, 20% (35 m, 71% (40 m, and 67% (45 m. There was a notable effect of the distances on the amount of tissue collected 20 m offered the best results. Dart gun pressure had no effect on the amount of tissue samples obtained. The amount of tissue obtained from successful darts was the same whether the animal was darted on the shoulder or thigh. In this paper, we present a practical guideline for remote biopsy darting of wildebeest to obtain optimum amount of tissue samples, which could be generalized for similar wild land mammalian species.

  1. Accuracy of identification of tissue types in endoscopic esophageal mucosal biopsies used for molecular biology studies

    Directory of Open Access Journals (Sweden)

    Plauto Beck

    2009-02-01

    , tissue heterogeneity was observed in clinical histopathology, with portions of squamous epithelium within the samples. Matches with pure tissue samples in both clinical and research histopathology levels were observed on 22 (26.2% levels of metaplastic columnar-lined epithelium and in 55 (40.7% levels of columnar-lined epithelium with intestinal metaplasia.Conclusions: The high proportion of mismatches and tissue heterogeneity observed, especially among columnar-lined epithelium with intestinal metaplasia and dysplasia, points to the necessity of determining the histopathology of the research samples to avoid sampling errors during molecular studies.Keywords: esophageal biopsies, endoscopy, columnar-lined epithelium, Barrett’s esophagus

  2. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  3. Satellite tagging and biopsy sampling of killer whales at subantarctic Marion Island: effectiveness, immediate reactions and long-term responses.

    Directory of Open Access Journals (Sweden)

    Ryan R Reisinger

    Full Text Available Remote tissue biopsy sampling and satellite tagging are becoming widely used in large marine vertebrate studies because they allow the collection of a diverse suite of otherwise difficult-to-obtain data which are critical in understanding the ecology of these species and to their conservation and management. Researchers must carefully consider their methods not only from an animal welfare perspective, but also to ensure the scientific rigour and validity of their results. We report methods for shore-based, remote biopsy sampling and satellite tagging of killer whales Orcinus orca at Subantarctic Marion Island. The performance of these methods is critically assessed using 1 the attachment duration of low-impact minimally percutaneous satellite tags; 2 the immediate behavioural reactions of animals to biopsy sampling and satellite tagging; 3 the effect of researcher experience on biopsy sampling and satellite tagging; and 4 the mid- (1 month and long- (24 month term behavioural consequences. To study mid- and long-term behavioural changes we used multievent capture-recapture models that accommodate imperfect detection and individual heterogeneity. We made 72 biopsy sampling attempts (resulting in 32 tissue samples and 37 satellite tagging attempts (deploying 19 tags. Biopsy sampling success rates were low (43%, but tagging rates were high with improved tag designs (86%. The improved tags remained attached for 26±14 days (mean ± SD. Individuals most often showed no reaction when attempts missed (66% and a slight reaction-defined as a slight flinch, slight shake, short acceleration, or immediate dive-when hit (54%. Severe immediate reactions were never observed. Hit or miss and age-sex class were important predictors of the reaction, but the method (tag or biopsy was unimportant. Multievent trap-dependence modelling revealed considerable variation in individual sighting patterns; however, there were no significant mid- or long-term changes

  4. Remote biopsy darting and marking of polar bears

    Science.gov (United States)

    Pagano, Anthony M.; Peacock, Elizabeth; McKinney, Melissa A.

    2014-01-01

    Remote biopsy darting of polar bears (Ursus maritimus) is less invasive and time intensive than physical capture and is therefore useful when capture is challenging or unsafe. We worked with two manufacturers to develop a combination biopsy and marking dart for use on polar bears. We had an 80% success rate of collecting a tissue sample with a single biopsy dart and collected tissue samples from 143 polar bears on land, in water, and on sea ice. Dye marks ensured that 96% of the bears were not resampled during the same sampling period, and we recovered 96% of the darts fired. Biopsy heads with 5 mm diameters collected an average of 0.12 g of fur, tissue, and subcutaneous adipose tissue, while biopsy heads with 7 mm diameters collected an average of 0.32 g. Tissue samples were 99.3% successful (142 of 143 samples) in providing a genetic and sex identification of individuals. We had a 64% success rate collecting adipose tissue and we successfully examined fatty acid signatures in all adipose samples. Adipose lipid content values were lower compared to values from immobilized or harvested polar bears, indicating that our method was not suitable for quantifying adipose lipid content.

  5. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  6. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  7. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  8. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  9. Use of Biopsy Tissue Samples, Incubated In Vitro for Autoradiographic Measurement of Cell Proliferation in Human Tissues; Utilisation de Biopsies Incubees In Vitro pour la Mesure Autoradiographique de la Proliferation Cellulaire de Tissus Humains

    Energy Technology Data Exchange (ETDEWEB)

    Galand, P. [Faculte de Medecine de l' Universite Libre de Bruxelles, Bruxelles (Belgium)

    1970-02-15

    ) choice of the region of the sample where homogeneous labelling occurs after the diffusion of the labelled thymidine, and (3) tests on the stability of the biopsy during incubation. This was done by using varied time interval between {sup 3}H-thymidine administrations. The good correlation between the results obtained in this way also gives supports to the validity of our distinction between the two kinds of labelling intensity. In conclusion, this method could be applied to several types of tissues, provided they can be obtained by biopsy, and with proper safeguards, namely in the choice of the doses range and in the definition of the proliferating population. (author) [French] Afin d'eviter les risques d'effets radiobiologiques lies a l'utilisation de thymidine tritiee, plusieurs chercheurs ont procede a des incubations de biopsies in vitro en presence de ce precurseur radiomarque de l'ADN. Ils s' efforcaient de definir le taux de proliferation cellulaire d'apres la distribution et l' intensite du marquage dans les autoradiographies. Toutefois, pour evaluer exactement la duree du cycle mitotique ou temps de generation, il est necessaire de connaitrez duree de la phase S (phase de synthese de l'ADN), car l'index de marquage ne depend que de l'importance de cette phase par rapport a la duree totale du cycle mitotique. L'auteur a choisi la methode du 'double marquage', utilisant deux differentes doses de thymidine tritiee, qui a ete mise au point par Maurer et ses collaborateurs. En administrant deux doses du precurseur tritie (une dose faible et une dose forte) a un intervalle de temps donne et en soumettant le tissu traite au processus autobiographique, on peut calculer la duree (s) de la phase S d'apres la formule N{sub F}/N{sub f} = S/t. Np est le nombre de noyaux fortement marques (c'est-a-dire les noyaux qui etaient en phase S pendant le deuxieme marquage); Nf est le nombre de noyaux faiblement marques, correspondant aux cellules qui ont quitte la phase S pendant l

  10. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo; Matsumoto, Tomohiro; Hasebe, Terumitsu; Kakizawa, Hideaki; Toyoda, Naoyuki

    2014-01-01

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  11. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  12. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  13. Investigation of tissue cellularity at the tip of the core biopsy needle with optical coherence tomography.

    Science.gov (United States)

    Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H

    2018-02-01

    We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.

  14. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  15. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  16. Culture methods of allograft musculoskeletal tissue samples in Australian bacteriology laboratories.

    Science.gov (United States)

    Varettas, Kerry

    2013-12-01

    Samples of allograft musculoskeletal tissue are cultured by bacteriology laboratories to determine the presence of bacteria and fungi. In Australia, this testing is performed by 6 TGA-licensed clinical bacteriology laboratories with samples received from 10 tissue banks. Culture methods of swab and tissue samples employ a combination of solid agar and/or broth media to enhance micro-organism growth and maximise recovery. All six Australian laboratories receive Amies transport swabs and, except for one laboratory, a corresponding biopsy sample for testing. Three of the 6 laboratories culture at least one allograft sample directly onto solid agar. Only one laboratory did not use a broth culture for any sample received. An international literature review found that a similar combination of musculoskeletal tissue samples were cultured onto solid agar and/or broth media. Although variations of allograft musculoskeletal tissue samples, culture media and methods are used in Australian and international bacteriology laboratories, validation studies and method evaluations have challenged and supported their use in recovering fungi and aerobic and anaerobic bacteria.

  17. Optical biopsy of breast tissue using differential path-length spectroscopy

    International Nuclear Information System (INIS)

    Veen, Robert L P van; Amelink, Arjen; Menke-Pluymers, Marian; Pol, Carmen van der; Sterenborg, Henricus J C M

    2005-01-01

    Differential path-length spectroscopy (DPS) was used to determine the local optical properties of breast tissue in vivo. DPS measurements were made on healthy and malignant breast tissue using a fibre-optic needle probe, and were correlated to the histological outcome of core-needle biopsies taken from the same location as the measurements. DPS yields information on the local tissue blood content, the local blood oxygenation, the average micro-vessel diameter, the β-carotene concentration and the scatter slope. Our data show that malignant breast tissue is characterized by a significant decrease in tissue oxygenation and a higher blood content compared to normal breast tissue

  18. Short Communication Evaluation of an underwater biopsy probe for ...

    African Journals Online (AJOL)

    This study evaluated the use of a novel underwater biopsy probe designed to collect muscle and dermal tissue samples from large (170–220 cm total length), free-swimming bull sharks Carcharhinus leucas. The biopsy probe tissue retention rate was 87% after 23 trials, and the mean size of retained tissue was 310 mg (SD ...

  19. Validation of an LC-MS/MS method to measure tacrolimus in rat kidney and liver tissue and its application to human kidney biopsies.

    Science.gov (United States)

    Noll, Benjamin D; Coller, Janet K; Somogyi, Andrew A; Morris, Raymond G; Russ, Graeme R; Hesselink, Dennis A; Van Gelder, Teun; Sallustio, Benedetta C

    2013-10-01

    Tacrolimus (TAC) has a narrow therapeutic index and high interindividual and intraindividual pharmacokinetic variability, necessitating therapeutic drug monitoring to individualize dosage. Recent evidence suggests that intragraft TAC concentrations may better predict transplant outcomes. This study aimed to develop a method for the quantification of TAC in small biopsy-sized samples of rat kidney and liver tissue, which could be applied to clinical biopsy samples from kidney transplant recipients. Kidneys and livers were harvested from Mrp2-deficient TR- Wistar rats administered TAC (4 mg·kg·d for 14 days, n = 8) or vehicle (n = 10). Tissue samples (0.20-1.00 mg of dry weight) were solubilized enzymatically and underwent liquid-liquid extraction before analysis by liquid chromatography tandem mass spectrometry method. TAC-free tissue was used in the calibrator and quality control samples. Analyte detection was accomplished using positive electrospray ionization (TAC: m/z 821.5 → 768.6; internal standard ascomycin m/z 809.3 → 756.4). Calibration curves (0.04-2.6 μg/L) were linear (R > 0.99, n = 10), with interday and intraday calibrator coefficients of variation and bias <17% at the lower limit of quantification and <15% at all other concentrations (n = 6-10). Extraction efficiencies for TAC and ascomycin were approximately 70%, and matrix effects were minimal. Rat kidney TAC concentrations were higher (range 109-190 pg/mg tissue) than those in the liver (range 22-53 pg/mg of tissue), with median tissue/blood concentrations ratios of 72.0 and 17.6, respectively. In 2 transplant patients, kidney TAC concentrations ranged from 119 to 285 pg/mg of tissue and were approximately 20 times higher than whole blood trough TAC concentrations. The method displayed precision and accuracy suitable for application to TAC measurement in human kidney biopsy tissue.

  20. Targeted histology sampling from atypical small acinar proliferation area detected by repeat transrectal prostate biopsy

    Directory of Open Access Journals (Sweden)

    A. V. Karman

    2017-01-01

    Full Text Available Оbjective: to define the approach to the management of patients with the detected ASAP area.Materials and methods. In the time period from 2012 through 2015, 494 patients with previously negative biopsy and remaining suspicion of prostate cancer (PCa were examined. The patients underwent repeat 24-core multifocal prostate biopsy with taking additional tissue samples from suspicious areas detected by multiparametric magnetic resonance imaging and transrectal ultrasound. An isolated ASAP area was found in 127 (25. 7 % of the 494 examined men. All of them were offered to perform repeat target transrectal biopsy of this area. Targeted transrectal ultrasound guided biopsy of the ASAP area was performed in 56 (44.1 % of the 127 patients, 53 of them being included in the final analysis.Results. PCa was diagnosed in 14 (26.4 % of the 53 patients, their mean age being 64.4 ± 6.9 years. The average level of prostate-specific antigen (PSA in PCa patients was 6.8 ± 3.0 ng/ml, in those with benign lesions – 9.3 ± 6.5 ng/ml; the percentage ratio of free/total PSA with PCa was 16.2 ± 7,8 %, with benign lesions – 23.3 ± 7.7 %; PSA density in PCa patients was 0.14 ± 0.07 ng/ml/cm3, in those with benign lesions – 0.15 ± 0.12 ng/ml/cm3. Therefore, with ASAP area being detected in repeat prostate biopsy samples, it is advisable that targeted extended biopsy of this area be performed. 

  1. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  2. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  3. Postprandial Responses to Lipid and Carbohydrate Ingestion in Repeated Subcutaneous Adipose Tissue Biopsies in Healthy Adults

    Directory of Open Access Journals (Sweden)

    Aimee L. Dordevic

    2015-07-01

    Full Text Available Adipose tissue is a primary site of meta-inflammation. Diet composition influences adipose tissue metabolism and a single meal can drive an inflammatory response in postprandial period. This study aimed to examine the effect lipid and carbohydrate ingestion compared with a non-caloric placebo on adipose tissue response. Thirty-three healthy adults (age 24.5 ± 3.3 year (mean ± standard deviation (SD; body mass index (BMI 24.1 ± 3.2 kg/m2, were randomised into one of three parallel beverage groups; placebo (water, carbohydrate (maltodextrin or lipid (dairy-cream. Subcutaneous, abdominal adipose tissue biopsies and serum samples were collected prior to (0 h, as well as 2 h and 4 h after consumption of the beverage. Adipose tissue gene expression levels of monocyte chemoattractant protein-1 (MCP-1, interleukin 6 (IL-6 and tumor necrosis factor-α (TNF-α increased in all three groups, without an increase in circulating TNF-α. Serum leptin (0.6-fold, p = 0.03 and adipose tissue leptin gene expression levels (0.6-fold, p = 0.001 decreased in the hours following the placebo beverage, but not the nutrient beverages. Despite increased inflammatory cytokine gene expression in adipose tissue with all beverages, suggesting a confounding effect of the repeated biopsy method, differences in metabolic responses of adipose tissue and circulating adipokines to ingestion of lipid and carbohydrate beverages were observed.

  4. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  5. Metagenomic analysis reveals presence of Treponema denticola in a tissue biopsy of the Iceman.

    Directory of Open Access Journals (Sweden)

    Frank Maixner

    Full Text Available Ancient hominoid genome studies can be regarded by definition as metagenomic analyses since they represent a mixture of both hominoid and microbial sequences in an environment. Here, we report the molecular detection of the oral spirochete Treponema denticola in ancient human tissue biopsies of the Iceman, a 5,300-year-old Copper Age natural ice mummy. Initially, the metagenomic data of the Iceman's genomic survey was screened for bacterial ribosomal RNA (rRNA specific reads. Through ranking the reads by abundance a relatively high number of rRNA reads most similar to T. denticola was detected. Mapping of the metagenome sequences against the T. denticola genome revealed additional reads most similar to this opportunistic pathogen. The DNA damage pattern of specifically mapped reads suggests an ancient origin of these sequences. The haematogenous spread of bacteria of the oral microbiome often reported in the recent literature could already explain the presence of metagenomic reads specific for T. denticola in the Iceman's bone biopsy. We extended, however, our survey to an Iceman gingival tissue sample and a mouth swab sample and could thereby detect T. denticola and Porphyrimonas gingivalis, another important member of the human commensal oral microflora. Taken together, this study clearly underlines the opportunity to detect disease-associated microorganisms when applying metagenomics-enabled approaches on datasets of ancient human remains.

  6. Assessment of molecular markers demonstrates concordance between samples acquired via stereotactic biopsy and open craniotomy in both anaplastic astrocytomas and glioblastomas.

    Science.gov (United States)

    Gessler, Florian; Baumgarten, Peter; Bernstock, Joshua D; Harter, Patrick; Lescher, Stephanie; Senft, Christian; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-06-01

    The classification, treatment and prognosis of high-grade gliomas has been shown to correlate with the expression of molecular markers (e.g. MGMT promotor methylation and IDH1 mutations). Acquisition of tumor samples may be obtained via stereotactic biopsy or open craniotomy. Between the years 2009 and 2013, 22 patients initially diagnosed with HGGs via stereotactic biopsy, that ultimately underwent open craniotomy for resection of their tumor were prospectively included in an institutional glioma database. MGMT promotor analysis was performed using methylation-specific (MS)-PCR and IDH1R132H mutation analysis was performed using immunohistochemistry. Three patients (13.7%) exhibited IDH1R132H mutations in samples obtained via stereotactic biopsy. Tissue derived from stereotaxic biopsy was demonstrated to have MGMT promotor methylation in ten patients (45.5%), while a non-methylated MGMT promotor was demonstrated in ten patients (45.5%); inconclusive results were obtained for the remaining two patients (9%) within our cohort. The initial histologic grading, IDH1R132H mutation and MGMT promotor methylation results were confirmed using samples obtained during open craniotomy in all but one patient; here inconclusive MGMT promotor analysis was obtained in contrast to that which was obtained via stereotactic biopsy. Tumor samples acquired via stereotactic biopsy provide accurate information with regard to clinically relevant molecular markers that have been shown to impact patient care decisions. The profile of markers analyzed in our cohort was nearly concordant between those samples obtained via stereotactic biopsy or open craniotomy thereby suggesting that clinical decisions may be based on the molecular profile of the tumor samples obtained via stereotactic biopsy.

  7. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  8. Three cases of systemic amyloidosis successfully diagnosed by subcutaneous fat tissue biopsy of the hip

    Directory of Open Access Journals (Sweden)

    Arahata M

    2016-08-01

    Full Text Available Masahisa Arahata,1 Shigeru Shimadoi,1 Satosi Yamatani,1 Shin-ichi Hayashi,2 Shigeharu Miwa,2 Hidesaku Asakura,3 Shinji Nakao4 1Department of Internal Medicine, Nanto Municipal Hospital, Nanto, 2Department of Diagnostic Pathology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, 3Department of Internal Medicine (III, 4Department of Cellular Transplantation Biology, Division of Cancer Medicine, Graduate School of Medical Science, Kanazawa University, Kanazawa, Japan Abstract: Fine-needle aspiration biopsy of the abdominal fat pad is considered to be a minimally invasive procedure for diagnosing systemic amyloidosis. However, this procedure is sometimes difficult and can be dangerous for elderly patients whose abdominal fat layer is thin because of malnutrition. In such cases, alternative diagnostic methods are required. We report three elderly patients with heart failure complicated by malnutrition. In all cases, electrocardiogram showed low voltage in the limb leads and a pseudoinfarct pattern in the chest leads, and echocardiography showed left ventricular wall thickening with granular sparkling appearance. These patients were suspected of having amyloid cardiomyopathy but could not undergo myocardial biopsies because of their poor conditions. After failed attempts at biopsy of the abdominal fat pad or the other organs, subcutaneous fat tissue biopsy over the hip led to the diagnosis of systemic amyloidosis with cardiomyopathy. The resultant diagnosis guided us to choose the appropriate treatment for the patients. This article illustrates that subcutaneous fat tissue biopsy of the hip could be a useful procedure for diagnosing systemic amyloidosis in elderly patients, particularly when a fat tissue biopsy of the abdomen is associated with a high risk of complications because of malnutrition. Keywords: systemic amyloidosis, amyloid cardiomyopathy, fine-needle aspiration biopsy, subcutaneous fat tissue, hip

  9. Effects of a Multidisciplinary Approach to Improve Volume of Diagnostic Material in CT-Guided Lung Biopsies.

    Science.gov (United States)

    Ferguson, Philip E; Sales, Catherine M; Hodges, Dalton C; Sales, Elizabeth W

    2015-01-01

    Recent publications have emphasized the importance of a multidisciplinary strategy for maximum conservation and utilization of lung biopsy material for advanced testing, which may determine therapy. This paper quantifies the effect of a multidisciplinary strategy implemented to optimize and increase tissue volume in CT-guided transthoracic needle core lung biopsies. The strategy was three-pronged: (1) once there was confidence diagnostic tissue had been obtained and if safe for the patient, additional biopsy passes were performed to further increase volume of biopsy material, (2) biopsy material was placed in multiple cassettes for processing, and (3) all tissue ribbons were conserved when cutting blocks in the histology laboratory. This study quantifies the effects of strategies #1 and #2. This retrospective analysis comparing CT-guided lung biopsies from 2007 and 2012 (before and after multidisciplinary approach implementation) was performed at a single institution. Patient medical records were reviewed and main variables analyzed include biopsy sample size, radiologist, number of blocks submitted, diagnosis, and complications. The biopsy sample size measured was considered to be directly proportional to tissue volume in the block. Biopsy sample size increased 2.5 fold with the average total biopsy sample size increasing from 1.0 cm (0.9-1.1 cm) in 2007 to 2.5 cm (2.3-2.8 cm) in 2012 (Pstrategy to CT-guided lung biopsies was effective in significantly increasing tissue volume and number of blocks available for advanced diagnostic testing.

  10. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  11. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    Science.gov (United States)

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  12. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  13. A case of Churg-Strauss syndrome: tissue diagnosis established by sigmoidoscopic rectal biopsy.

    Science.gov (United States)

    Leen, E J; Rees, P J; Sanderson, J D; Wilkinson, M L; Filipe, M I

    1996-01-01

    A case is presented of Churg-Strauss syndrome in a young man in whom the definitive diagnostic procedure was a full thickness sigmoidoscopic rectal biopsy, with submucosal sampling. Gastrointestinal changes in Churg-Strauss syndrome, a rare systemic illness characterised by asthma, blood and tissue eosinophilia, vasculitis, and granulomatous inflammation are common but poorly reported. The endoscopic and histopathological features of a case are described and emphasise the potential value of a limited sigmoidoscopy in establishing the diagnosis, when lower gastrointestinal symptoms are present. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 PMID:8801216

  14. Comparing the proteome of snap frozen, RNAlater preserved, and formalin-fixed paraffin-embedded human tissue samples

    DEFF Research Database (Denmark)

    Bennike, Tue Bjerg; Kastaniegaard, Kenneth; Padurariu, Simona

    2016-01-01

    Large biobanks exist worldwide containing formalin-fixed, paraffin-embedded samples and samples stored in RNAlater. However, the impact of tissue preservation on the result of a quantative proteome analysis remains poorly described.Human colon mucosal biopsies were extracted from the sigmoideum...

  15. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    Science.gov (United States)

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  16. Percutaneous CT-guided sacroiliac joint sampling for infection. Aspiration, biopsy, and technique

    Energy Technology Data Exchange (ETDEWEB)

    Knipp, David; Simeone, F.J.; Huang, Ambrose J.; Chang, Connie Y. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Nelson, Sandra B. [Massachusetts General Hospital, Infectious Disease Unit, Department of Medicine, Boston, MA (United States)

    2018-04-15

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning. (orig.)

  17. Real-time in vivo tissue characterization with diffuse reflectance spectroscopy during transthoracic lung biopsy: a clinical feasibility study

    NARCIS (Netherlands)

    Spliethoff, Jarich; Prevoo, Warner; Meier, Mark A.J.; de Jong, Jeroen; Evers, Daniel; Evers, Daniel J.; Sterenborg, Hendricus J.C.M.; Lucassen, Gerald; Lucassen, Gerald W.; Hendriks, Benno H.W.; Ruers, Theo J.M.

    2016-01-01

    Purpose: This study presents the first in vivo real-time tissue characterization during image-guided percutaneous lung biopsies using diffuse reflectance spectroscopy (DRS) sensing at the tip of a biopsy needle with integrated optical fibers. Experimental Design: Tissues from 21 consented patients

  18. Identification of proteomic biomarkers predicting prostate cancer aggressiveness and lethality despite biopsy-sampling error

    OpenAIRE

    Shipitsin, M; Small, C; Choudhury, S; Giladi, E; Friedlander, S; Nardone, J; Hussain, S; Hurley, A D; Ernst, C; Huang, Y E; Chang, H; Nifong, T P; Rimm, D L; Dunyak, J; Loda, M

    2014-01-01

    Background: Key challenges of biopsy-based determination of prostate cancer aggressiveness include tumour heterogeneity, biopsy-sampling error, and variations in biopsy interpretation. The resulting uncertainty in risk assessment leads to significant overtreatment, with associated costs and morbidity. We developed a performance-based strategy to identify protein biomarkers predictive of prostate cancer aggressiveness and lethality regardless of biopsy-sampling variation. Methods: Prostatectom...

  19. COMPARATIVE STUDY OF ENDOMETRIAL SAMPLING USING PIPELLE WITH HYSTEROSCOPIC-GUIDED BIOPSY

    Directory of Open Access Journals (Sweden)

    Nalina S

    2017-07-01

    Full Text Available BACKGROUND Hysteroscopic-guided biopsy is the gold standard for endometrial sampling, but it carries risk of general anaesthesia, infection and perforation, whereas Pipelle does not require anaesthesia or cervical dilatation and it allows outpatient and painless endometrial sampling. The aim of the study is to determine the reliability and accuracy of Pipelle aspiration in acquiring an adequate and representative endometrial sample and to compare its histopathology with hysteroscopic-directed biopsy. MATERIALS AND METHODS A prospective observational comparative study evaluating the role of Pipelle aspiration as an outpatient procedure in endometrial sampling of perimenopausal women with AUB. 150 perimenopausal women with clinical diagnosis of abnormal uterine bleeding were selected from the Gynaecology OPD of IOG, Chennai, between October 2014 and September 2015. They were subjected to endometrial sampling by Pipelle followed by hysteroscopic-directed biopsy. The efficacy of Pipelle was determined by correlating the histopathological results obtained from it and the hysteroscopic-directed biopsy. RESULTS The histopathology of the endometrium obtained using Pipelle’s curette showed a sensitivity of 93%, specificity of 90% in the detection of abnormal findings with PPV of 88% and NPV of 94%. However, accuracy of Pipelle is found to be less in the diagnosis of polyps and submucous fibroids with accuracy of nearing 100% when using hysteroscopy. CONCLUSION Pipelle endometrial sampling is convenient, easy, painless and safe in obtaining an adequate sample for histopathology with high sensitivity and specificity for endometrial pathologies and endometrial carcinoma.

  20. Comparison of diagnostic efficacy between CLE, tissue sampling, and CLE combined with tissue sampling for undetermined pancreaticobiliary strictures: a meta-analysis.

    Science.gov (United States)

    Gao, Ya-Dong; Qu, Ya-Wei; Liu, Hai-Feng

    2018-04-01

    The accurate diagnosis of undetermined pancreaticobiliary strictures remains challenging. Current ERCP-guided tissue sampling methods are of low sensitivity. Confocal laser endomicroscopy (CLE) is a new procedure and allows real optical biopsies that may improve the diagnosis of undetermined pancreaticobiliary strictures. The aim of this meta-analysis was to determine the diagnostic yield of CLE, tissue sampling, and CLE combined with tissue sampling for undetermined pancreaticobiliary strictures. Pubmed, Embase, and the Cochrane Library database were reviewed for relevant studies. Pooled estimates of sensitivity and specificity with 95% confidence intervals (CIs) were calculated using the random-effects meta-analysis model. The summary receiver-operating characteristic (SROC) curve was constructed, and the area under the receiver operating characteristic curve (AUC) was calculated. Twelve studies involving 591 patients were enrolled in our analysis. The overall sensitivity and the specificity estimate of CLE for discriminating benign and malignant pancreaticobiliary strictures were 87% (95%CI, 83-91%) and 76% (95%CI, 70-81%), respectively. The AUC to assess the diagnostic efficacy was 0.8705. For tissue sampling, the overall sensitivity and the specificity estimate were 64% (95%CI, 57-70%) and 94% (95%CI, 90-97%), respectively. The AUC to assess the diagnostic efficacy was 0.8040. A combination of both methods increased the sensitivity (93%; 95%CI, 88-96%) with a specificity of 82% (95%CI, 74-89%). The AUC to assess the diagnostic efficacy was 0.9377. There was no publication bias by Deeks' Funnel Plot with p = .936. Compared with tissue sampling, CLE may increase the sensitivity for the diagnosis of malignant pancreaticobiliary strictures. A combination of both can effectively diagnose malignant pancreaticobiliary strictures.

  1. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna/Vienna General Hospital, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Amann, Gabriele [Medical University of Vienna, Clinical Institute for Pathology, Vienna (Austria); Krssak, Martin [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Department of Internal Medicine III, Endocrinology and Metabolism, Vienna (Austria); Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard [Medical University of Vienna, Department of Orthopaedics, Vienna (Austria); Szomolanyi, Pavol [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Weber, Michael; Czerny, Christian; Nemec, Stefan [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Breitenseher, Martin [Landesklinikum Waldviertel Horn, Horn (Austria); Grabner, Guenther; Bogner, Wolfgang [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Dominkus, Martin [Orthopaedics Hospital Speising, Vienna (Austria); Trattnig, Siegfried [Medical University of Vienna, High Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-07-15

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  2. Use of diagnostic dynamic contrast-enhanced (DCE)-MRI for targeting of soft tissue tumour biopsies at 3T: preliminary results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Amann, Gabriele; Krssak, Martin; Panotopoulos, Joannis; Funovics, Philipp; Windhager, Reinhard; Szomolanyi, Pavol; Weber, Michael; Czerny, Christian; Nemec, Stefan; Breitenseher, Martin; Grabner, Guenther; Bogner, Wolfgang; Dominkus, Martin; Trattnig, Siegfried

    2015-01-01

    To test the feasibility and accuracy of MR-guided soft tissue tumour biopsy at 3T, using the dynamic contrast-enhanced (DCE) information from staging MRI for intralesional targeting. After obtaining written informed consent for this institutional review board-approved study, 53 patients with suspected soft tissue tumours prospectively underwent preoperative staging MRI at 3T, including DCE, and subsequent MR-guided core needle biopsy. In 44/53 cases, DCE was heterogeneous and was used for intralesional biopsy targeting. Surgical, whole-specimen histology was used as the gold standard in 43/44 patients and revealed 42 soft tissue tumours (24 men; 18 women; mean age, 52 years; range, 19 - 84). Final surgical histology revealed eight benign lesions, six tumours of intermediate dignity, and 28 malignancies. All malignancies had shown heterogeneous DCE. The diagnostic yield of the biopsies was 100 % (42/42). Histological accuracy rates of biopsy were 100 % in predicting the dignity (42/42; 95 % CI [0.916 - 1.000]), 95.2 % for the tissue-specific entity (40/42; 95 % CI [0.847 - 0.987]), and 90.5 % for the tumour grade (38/42; 95 % CI [0.779 - 0.962]). Our preliminary study indicates that biopsy of soft tissue tumours can be performed accurately and safely with DCE targeted MR-guidance at 3T, using a combined staging/biopsy MRI protocol. (orig.)

  3. CT‑guided percutaneous transthoracic lung biopsy: First experience ...

    African Journals Online (AJOL)

    Percutaneous lung biopsy had been described in the nineteenth century by Leyden, but image- guided needle chest biopsy only gained widespread acceptance in the 1970s. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis cannot be obtained by the non-invasive techniques and cytological ...

  4. [Transabdominal chorionic villus sampling using biopsy forceps or needle: pregnancy outcomes by technique used].

    Science.gov (United States)

    Spallina, J; Anselem, O; Haddad, B; Touboul, C; Tsatsaris, V; Le Ray, C

    2014-11-01

    To compare pregnancy outcomes after transabdominal chorionic villus sampling using biopsy forceps or needle. Retrospective bicentric study including all women who had a transabdominal chorionic villus sampling between 2005 and 2009 (172 using biopsy forceps and 160 using needle). The primary endpoint was the rate of fetal loss, after excluding medical abortion due to the result of the biopsy. The secondary endpoint was the rate of premature rupture of the membrane. All cases were reviewed to try to determine the responsibility of the biopsy. The pregnancy outcomes were not different between the two groups: 4 (4.4%) fetal losses in the biopsy forceps group and 6 (7.4%) in the needle group (P=0.52). Only one case (1.2%) of fetal loss can be attributed to the biopsy, using a needle, and none (0%) following a forceps biospy (P=0.29). The rate of premature rupture of the membrane was comparable in the two groups. The pregnancy outcomes following chorionic villus sampling using a biopsy forceps or a needle seem comparable. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  5. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    Science.gov (United States)

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  6. Fatal mediastinal biopsy: How interventional radiology saves the day

    Directory of Open Access Journals (Sweden)

    Y Yaacob

    2012-01-01

    Full Text Available This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.

  7. GoM Coastal Biopsy Surveys - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Small vessel surveys were conducted within estuarine and nearshore coastal waters of Barataria Bay, LA and Mississippi Sound, MS to collect tissue biopsy samples...

  8. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  9. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  10. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  11. Biopsy of Different Oral Soft Tissues Lesions by KTP and Diode Laser: Histological Evaluation

    Directory of Open Access Journals (Sweden)

    Umberto Romeo

    2014-01-01

    Full Text Available Introduction. Oral biopsy aims to obtain clear and safe diagnosis; it can be performed by scalpel or laser. The controversy in this latter application is the thermal alteration due to tissue heating. The aim of this study is the histological evaluation of margins of “in vivo” biopsies collected by diode and KTP lasers. Material and Methods. 17 oral benign lesions biopsies were made by diode 808 nm (SOL, DenMatItalia, Italy and KTP 532 nm (SmartLite, DEKA, Italy. Samples were observed at OM LEICA DM 2000; margin alterations were evaluated through Leica Application Suite 3.4. Results. Epithelial and connective damages were assessed for each pathology with an average of 0.245 mm and a standard deviation of ±0.162 mm in mucoceles, 0.382 mm ± 0.149 mm in fibromas, 0.336 mm ± 0.106 mm in hyperkeratosis, 0.473 mm ± 0.105 mm in squamous hyperplasia, 0.182 mm in giant cell granuloma, and 0.149 mm in melanotic macula. Discussion. The histologic aspect of lesions influenced the response to laser, whereas the greater inflammation and cellularity were linked with the higher thermal signs. Many artifacts were also associated to histologic procedures. Conclusion. Both tested lasers permitted sure histologic diagnosis. However, it is suggested to enlarge biopsies of about 0.5 mm, to avoid thermal alterations, especially in inflammatory lesions like oral lichen planus.

  12. [Gene expression analyses of kidney biopsies: the European renal cDNA bank--Kröner-Fresenius biopsy bank].

    Science.gov (United States)

    Cohen, C D; Kretzler, M

    2009-03-01

    Histological analysis of kidney biopsies is an essential part of our current diagnostic workup of patients with renal disease. Besides the already established diagnostic tools, new methods allow extensive analysis of the sample tissue's gene expression. Using results from a European multicenter study on gene expression analysis of renal biopsies, in this review we demonstrate that this novel approach not only expands the scope of so-called basic research but also might supplement future biopsy diagnostics. The goals are improved diagnosis and more specific therapy choice and prognosis estimates.

  13. Direct measurement of catalase activity in living cells and tissue biopsies

    International Nuclear Information System (INIS)

    Scaglione, Christine N.; Xu, Qijin; Ramanujan, V. Krishnan

    2016-01-01

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear

  14. Direct measurement of catalase activity in living cells and tissue biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Scaglione, Christine N.; Xu, Qijin; Ramanujan, V. Krishnan, E-mail: Ramanujanv@csmc.edu

    2016-01-29

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies – can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. - Highlights: • A novel, direct measurement of Catalase enzyme activity via, oxygen sensing method. • Steady-stateprofiles of Catalase activity follow the Michaelis-Menten Kinetics. • Catalase-specific activity demonstrated using genetic and pharmacological tools. • Overcomes limitations of spectroscopic methods and indirect calorimetric approaches. • Clear

  15. GoM Coastal and Estuarine Biopsy Surveys

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Small vessel surveys are conducted within estuarine and nearshore coastal waters to collect tissue biopsy samples from bottlenose dolphins. Visual surveys are...

  16. Endoductal tissue sampling of biliary strictures through endoscopic retrograde cholangiopan creatography (ERCP).

    Science.gov (United States)

    Pugliese, V; Antonelli, G; Vincenti, M; Gatteschi, B

    1997-01-01

    Pathological proof of malignant in biliary strictures is useful in the preoperative setting as it helps define therapeutic planning and prognosis, and reduces the length of the subsequent surgical intervention. However, it is difficult to obtain. The aim of this study was to evaluate the yield of histological and cytological examination of endobiliary samples obtained during endoscopic retrograde cholangiopancreatography (ERCP). Endobiliary forceps biopsy and brush cytology were performed during ERCP examination in 52 consecutive patients, 36 with malignant and 16 with benign strictures. Histology and cytology turned out to have the same sensitivity (53%). The gain in sensitivity achieved by combining the two techniques was limited, reaching a value of 61%. The specificity, however, was 100% for both methods. Most of the few complications observed were due to sphincterotomy and subsided spontaneously or with medical treatment. However, one patient experienced a serous complication and chose to be treated by surgical intervention. The complication was caused by forceps biopsy. This study shows that 1) sampling of biliary strictures during ERCP is the primary approach to tissue diagnosis; 2) brush cytology alone is sufficient in clinical practice; 3) forceps biopsy must always be used to sample intra-ampullary strictures but should be considered as a secondary step to sample strictures located more proximally, in the bile ducta, if previous cytology was negative.

  17. The classification of secondary colorectal liver cancer in human biopsy samples using angular dispersive x-ray diffraction and multivariate analysis

    International Nuclear Information System (INIS)

    Theodorakou, Chrysoula; Farquharson, Michael J

    2009-01-01

    The motivation behind this study is to assess whether angular dispersive x-ray diffraction (ADXRD) data, processed using multivariate analysis techniques, can be used for classifying secondary colorectal liver cancer tissue and normal surrounding liver tissue in human liver biopsy samples. The ADXRD profiles from a total of 60 samples of normal liver tissue and colorectal liver metastases were measured using a synchrotron radiation source. The data were analysed for 56 samples using nonlinear peak-fitting software. Four peaks were fitted to all of the ADXRD profiles, and the amplitude, area, amplitude and area ratios for three of the four peaks were calculated and used for the statistical and multivariate analysis. The statistical analysis showed that there are significant differences between all the peak-fitting parameters and ratios between the normal and the diseased tissue groups. The technique of soft independent modelling of class analogy (SIMCA) was used to classify normal liver tissue and colorectal liver metastases resulting in 67% of the normal tissue samples and 60% of the secondary colorectal liver tissue samples being classified correctly. This study has shown that the ADXRD data of normal and secondary colorectal liver cancer are statistically different and x-ray diffraction data analysed using multivariate analysis have the potential to be used as a method of tissue classification.

  18. Breast MR biopsy: Pathological and radiological correlation

    International Nuclear Information System (INIS)

    Dratwa, Chloe; Chopier, Jocelyne; Jalaguier-Coudray, Aurelie; Thomassin-Piana, Jeanne; Gonin, Julie; Antoine, Martine; Trop, Isabelle; Darai, Emile; Thomassin-Naggara, Isabelle

    2016-01-01

    To identify pathological features for sample analysis of magnetic resonance imaging-guided vaccum-assisted breast biopsy (MRIgVaBB) to optimize radio pathological correlation and identify discordant benign result. Databases of two centres were queried to identify MRIgVaBB performed between January 2009 and February 2013. A cohort of 197 women (mean age: 54.5 years (24-77)) with 208 lesions was identified. We retrospectively analyzed all prebiopsy MRI examinations according to the new BI-RADS lexicon, and all biopsy samples to describe the lesion of interest, its interface with the surrounding breast tissue and other associated features. The malignancy rate was 26.0 % (54/208) with an underestimation rate of 15.67 % (5/32). A visible interface at pathology between a biopsied lesion and the surrounding breast tissue was more frequently identified in mass enhancement compared to NME or focus (p = 0.0003). Regional NME was correlated with a high degree of fibrosis (p = 0.001) and the presence of PASH (p = 0.0007). Linear or segmental NME was correlated with the presence of periductal mastitis (p = 0.0003). The description of a visible interface between the target lesion and the surrounding tissue is crucial to confirm the correct targeting of an MR mass or a NME. (orig.)

  19. Gene Expression Profiles in Paired Gingival Biopsies from Periodontitis-Affected and Healthy Tissues Revealed by Massively Parallel Sequencing

    Science.gov (United States)

    Båge, Tove; Lagervall, Maria; Jansson, Leif; Lundeberg, Joakim; Yucel-Lindberg, Tülay

    2012-01-01

    Periodontitis is a chronic inflammatory disease affecting the soft tissue and bone that surrounds the teeth. Despite extensive research, distinctive genes responsible for the disease have not been identified. The objective of this study was to elucidate transcriptome changes in periodontitis, by investigating gene expression profiles in gingival tissue obtained from periodontitis-affected and healthy gingiva from the same patient, using RNA-sequencing. Gingival biopsies were obtained from a disease-affected and a healthy site from each of 10 individuals diagnosed with periodontitis. Enrichment analysis performed among uniquely expressed genes for the periodontitis-affected and healthy tissues revealed several regulated pathways indicative of inflammation for the periodontitis-affected condition. Hierarchical clustering of the sequenced biopsies demonstrated clustering according to the degree of inflammation, as observed histologically in the biopsies, rather than clustering at the individual level. Among the top 50 upregulated genes in periodontitis-affected tissues, we investigated two genes which have not previously been demonstrated to be involved in periodontitis. These included interferon regulatory factor 4 and chemokine (C-C motif) ligand 18, which were also expressed at the protein level in gingival biopsies from patients with periodontitis. In conclusion, this study provides a first step towards a quantitative comprehensive insight into the transcriptome changes in periodontitis. We demonstrate for the first time site-specific local variation in gene expression profiles of periodontitis-affected and healthy tissues obtained from patients with periodontitis, using RNA-seq. Further, we have identified novel genes expressed in periodontitis tissues, which may constitute potential therapeutic targets for future treatment strategies of periodontitis. PMID:23029519

  20. Integrative analysis of copy number and gene expression in breast cancer using formalin-fixed paraffin-embedded core biopsy tissue: a feasibility study.

    Science.gov (United States)

    Iddawela, Mahesh; Rueda, Oscar; Eremin, Jenny; Eremin, Oleg; Cowley, Jed; Earl, Helena M; Caldas, Carlos

    2017-07-11

    An absence of reliable molecular markers has hampered individualised breast cancer treatments, and a major limitation for translational research is the lack of fresh tissue. There are, however, abundant banks of formalin-fixed paraffin-embedded (FFPE) tissue. This study evaluated two platforms available for the analysis of DNA copy number and gene expression using FFPE samples. The cDNA-mediated annealing, selection, extension, and ligation assay (DASL™) has been developed for gene expression analysis and the Molecular Inversion Probes assay (Oncoscan™), were used for copy number analysis using FFPE tissues. Gene expression and copy number were evaluated in core-biopsy samples from patients with breast cancer undergoing neoadjuvant chemotherapy (NAC). Forty-three core-biopsies were evaluated and characteristic copy number changes in breast cancers, gains in 1q, 8q, 11q, 17q and 20q and losses in 6q, 8p, 13q and 16q, were confirmed. Regions that frequently exhibited gains in tumours showing a pathological complete response (pCR) to NAC were 1q (55%), 8q (40%) and 17q (40%), whereas 11q11 (37%) gain was the most frequent change in non-pCR tumours. Gains associated with poor survival were 11q13 (62%), 8q24 (54%) and 20q (47%). Gene expression assessed by DASL correlated with immunohistochemistry (IHC) analysis for oestrogen receptor (ER) [area under the curve (AUC) = 0.95], progesterone receptor (PR)(AUC = 0.90) and human epidermal growth factor type-2 receptor (HER-2) (AUC = 0.96). Differential expression analysis between ER+ and ER- cancers identified over-expression of TTF1, LAF-4 and C-MYB (p ≤ 0.05), and between pCR vs non-pCRs, over-expression of CXCL9, AREG, B-MYB and under-expression of ABCG2. This study was an integrative analysis of copy number and gene expression using FFPE core biopsies and showed that molecular marker data from FFPE tissues were consistent with those in previous studies using fresh-frozen samples. FFPE tissue can provide

  1. Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Vienna General Hospital, Department of Radiology, Vienna (Austria); Hoffmann, Elisabeth; Schober, Ewald; Mostbeck, Gerhard [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Bernhardt, Klaus; Schalleschak, Johann [Otto Wagner Hospital, Department of Laboratory Medicine, Vienna (Austria); Rowhani, Marcel [Otto Wagner Hospital, Department of Respiratory and Critical Care Medicine, Vienna (Austria); Weber, Michael [Medical University of Vienna, Department of Radiology, Vienna (Austria)

    2011-09-15

    This study assessed the feasibility of telecytological evaluation of samples from CT-guided lung biopsies using a dynamic telecytological system in which the microscope was operated by personnel from the radiology department at the site of the biopsy and a cytologist off-site diagnosed the biopsy sample. 45 imprint samples from CT-guided biopsies of lung lesions were reviewed by two cytologists using a telecytological microscope (Olympus BX51, Tokyo, Japan). The telecytological microscope was operated by one radiologist and one radiology technician. The cytological samples were classified by a cytologist into four categories: benign, malignant, atypical cells of undetermined significance, and non-diagnostic. The results were compared with those of a previous consensus reading of two independent cytologists (gold standard). When the radiologist was operating the microscope, the diagnostic accuracy was 100% as both cytologists came to the correct diagnosis in all samples. When the technician operated the microscope, two diagnoses of cyotologist 1 differed from the gold standard. Thus, the accuracy for the technician was 95.56%. Telecytological evaluation of imprint samples from CT-guided lung biopsies is feasible because it can be performed with high diagnostic accuracy if personnel from the radiology department operate the microscope. (orig.)

  2. CT-guided stereotaxic biopsy in 104 cases of brain tumors

    International Nuclear Information System (INIS)

    Niizuma, Hiroshi; Nakasato, Nobukazu; Jokura, Hidehumi; Otsuki, Taisuke; Katakura, Ryuichi; Suzuki, Jiro

    1988-01-01

    Biopsy of suspected brain tumor was performed on 104 cases using Leksell's CT-guided stereotaxic system. The entire operation was performed in the CT room. A Backlund's spiral biopsy needle was advanced to the target point in a stepwise fashion and two to nine tissue samples were obtained from one to three biopsy tracks. Tissue sampling was impossible in two cases because the tumors were too hard for biopsy needle to advance. Also, sampling was sometimes difficult in the case of soft and necrotic tumor, cystic tumor, already treated (irradiated) tumor and the lesion including old blood clot. After the biopsy, minimal bleeding occurred in nine cases, however, stopped within 10 minutes by controlling the blood pressure. A minimum sized hematoma was visible on the postoperative CT in four cases. Postoperative neurological deterioration was seen in two cases. One case was transient and the other seemed to be in his natural course. Anyway, there were neither cases of operative mortality nor severely complicated cases in these series. Useful pathological diagnosis was possible in 83 cases (80 %). Accurate diagnosis was not possible in the remaining 21 cases, however, their histological datum such as necrosis, blood clot, and so on were very useful to estimate the lesions. In summary, accurate diagnosis rate of CT-guided stereotaxic needle biopsy was 80 %. However, it appeared to be a safe and useful procedure in the diagnosis of intracranial mass lesions. (author)

  3. PamFreezer: a solution to enable frozen biopsy logistics

    NARCIS (Netherlands)

    Colijn, B.A.; Rios Cruellas, G.; Hashemi-Shabastari, M.; Janssen, X.; van der Leij, A.; Leyte-Gonzalez, R.; Vanapalli, Srinivas; Veldhuizen, P.; Verbiest, G.; Verhaagen, B.

    2012-01-01

    Tissue samples that are taken during a biopsy need to be snap-frozen in order to preserve their properties and use the tissue for contemporary molecular biology technologies that may improve the treatment of the patient. There is currently a lack of (safe) methodologies or devices for snap- freezing

  4. The Orientation of Gastric Biopsy Samples Improves the Inter-observer Agreement of the OLGA Staging System.

    Science.gov (United States)

    Cotruta, Bogdan; Gheorghe, Cristian; Iacob, Razvan; Dumbrava, Mona; Radu, Cristina; Bancila, Ion; Becheanu, Gabriel

    2017-12-01

    Evaluation of severity and extension of gastric atrophy and intestinal metaplasia is recommended to identify subjects with a high risk for gastric cancer. The inter-observer agreement for the assessment of gastric atrophy is reported to be low. The aim of the study was to evaluate the inter-observer agreement for the assessment of severity and extension of gastric atrophy using oriented and unoriented gastric biopsy samples. Furthermore, the quality of biopsy specimens in oriented and unoriented samples was analyzed. A total of 35 subjects with dyspeptic symptoms addressed for gastrointestinal endoscopy that agreed to enter the study were prospectively enrolled. The OLGA/OLGIM gastric biopsies protocol was used. From each subject two sets of biopsies were obtained (four from the antrum, two oriented and two unoriented, two from the gastric incisure, one oriented and one unoriented, four from the gastric body, two oriented and two unoriented). The orientation of the biopsy samples was completed using nitrocellulose filters (Endokit®, BioOptica, Milan, Italy). The samples were blindly examined by two experienced pathologists. Inter-observer agreement was evaluated using kappa statistic for inter-rater agreement. The quality of histopathology specimens taking into account the identification of lamina propria was analyzed in oriented vs. unoriented samples. The samples with detectable lamina propria mucosae were defined as good quality specimens. Categorical data was analyzed using chi-square test and a two-sided p value <0.05 was considered statistically significant. A total of 350 biopsy samples were analyzed (175 oriented / 175 unoriented). The kappa index values for oriented/unoriented OLGA 0/I/II/III and IV stages have been 0.62/0.13, 0.70/0.20, 0.61/0.06, 0.62/0.46, and 0.77/0.50, respectively. For OLGIM 0/I/II/III stages the kappa index values for oriented/unoriented samples were 0.83/0.83, 0.88/0.89, 0.70/0.88 and 0.83/1, respectively. No case of OLGIM IV

  5. Detection of p53 gene mutations in bronchial biopsy samples of patients with lung cancer

    International Nuclear Information System (INIS)

    Irshad, S.; Nawaz, T.

    2008-01-01

    Lung cancer is the malignant transformation and expansion of lung tissue. It is the most lethal of all cancers worldwide, responsible for 1.2 million deaths annually. The goal of this study was to detect the p53 gene mutations in lung cancer, in local population of Lahore, Pakistan. These mutations were screened in the bronchial biopsy lung cancer tissue samples. For this purpose microtomed tissue sections were collected. Following DNA extraction from tissue sections, the p53 mutations were detected by amplifying Exon 7 (145 bp) and Exon 8 (152 bp) of the p53 gene. PCR then followed by single-strand conformation polymorphism analysis for screening the p53 gene mutations. This results of SSCP were visualized of silver staining. The results showed different banding pattern indicating the presence of mutation. Majority of the mutations were found in Exon 7. Exon 7 of p53 gene may be the mutation hotspot in lung cancer. In lung cancer, the most prevalent mutations of p53 gene are G -> T transversions; other types of insertions and deletions are also expected, however, the exact nature of mutations in presented work could be confirmed by direct sequencing. (author)

  6. Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Cazzato, Roberto Luigi; Garnon, Julien; Tsoumakidou, Georgia [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Avérous, Gerlinde [CHU Strasbourg Hautepierre, Department of Pathology (France); Caudrelier, Jean; Koch, Guillaume; Gangi, Afshin [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France)

    2017-04-15

    PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases described in this report.

  7. Detection of EGFR mutations in plasma and biopsies from non-small cell lung cancer patients by allele-specific PCR assays

    DEFF Research Database (Denmark)

    Weber, Britta; Meldgaard, Peter; Hager, Henrik

    2014-01-01

    samples with allele-specific PCR assays. METHODS: Pairs of the diagnostic biopsy and plasma obtained just prior to start of erlotinib treatment were collected from 199 patients with adenocarcinoma of non-small-cell lung cancer. DNA from both sample types was isolated and examined for the presence...... of mutations in exons 18-21 of the EGFR gene, employing the cobas(®) EGFR Tissue Test and cobas(®) EGFR Blood Test (in development, Roche Molecular Systems, Inc., CA, USA). RESULTS: Test results were obtained in all 199 (100%) plasma samples and 196/199 (98%) of the biopsies. EGFR-activating mutations were...... identified in 24/199 (12%) plasma samples and 28/196 (14%) biopsy samples, and 17/196 (9%) matched pairs contained the same mutation. Six EGFR mutations were present only in plasma samples but not in the biopsy samples. The overall concordance of the EGFR gene mutations detected in plasma and biopsy tissue...

  8. Bulk Genotyping of Biopsies Can Create Spurious Evidence for Hetereogeneity in Mutation Content.

    Directory of Open Access Journals (Sweden)

    Rumen Kostadinov

    2016-04-01

    Full Text Available When multiple samples are taken from the neoplastic tissues of a single patient, it is natural to compare their mutation content. This is often done by bulk genotyping of whole biopsies, but the chance that a mutation will be detected in bulk genotyping depends on its local frequency in the sample. When the underlying mutation count per cell is equal, homogenous biopsies will have more high-frequency mutations, and thus more detectable mutations, than heterogeneous ones. Using simulations, we show that bulk genotyping of data simulated under a neutral model of somatic evolution generates strong spurious evidence for non-neutrality, because the pattern of tissue growth systematically generates differences in biopsy heterogeneity. Any experiment which compares mutation content across bulk-genotyped biopsies may therefore suggest mutation rate or selection intensity variation even when these forces are absent. We discuss computational and experimental approaches for resolving this problem.

  9. Bulk Genotyping of Biopsies Can Create Spurious Evidence for Hetereogeneity in Mutation Content.

    Science.gov (United States)

    Kostadinov, Rumen; Maley, Carlo C; Kuhner, Mary K

    2016-04-01

    When multiple samples are taken from the neoplastic tissues of a single patient, it is natural to compare their mutation content. This is often done by bulk genotyping of whole biopsies, but the chance that a mutation will be detected in bulk genotyping depends on its local frequency in the sample. When the underlying mutation count per cell is equal, homogenous biopsies will have more high-frequency mutations, and thus more detectable mutations, than heterogeneous ones. Using simulations, we show that bulk genotyping of data simulated under a neutral model of somatic evolution generates strong spurious evidence for non-neutrality, because the pattern of tissue growth systematically generates differences in biopsy heterogeneity. Any experiment which compares mutation content across bulk-genotyped biopsies may therefore suggest mutation rate or selection intensity variation even when these forces are absent. We discuss computational and experimental approaches for resolving this problem.

  10. Respiratory analysis of coupled mitochondria in cryopreserved liver biopsies

    Directory of Open Access Journals (Sweden)

    Mercedes García-Roche

    2018-07-01

    Full Text Available The aim of this work was to develop a cryopreservation method of small liver biopsies for in situ mitochondrial function assessment. Herein we describe a detailed protocol for tissue collection, cryopreservation, high-resolution respirometry using complex I and II substrates, calculation and interpretation of respiratory parameters. Liver biopsies from cow and rat were sequentially frozen in a medium containing dimethylsulfoxide as cryoprotectant and stored for up to 3 months at −80 °C. Oxygen consumption rate studies of fresh and cryopreserved samples revealed that most respiratory parameters remained unchanged. Additionally, outer mitochondrial membrane integrity was assessed adding cytochrome c, proving that our cryopreservation method does not harm mitochondrial structure. In sum, we present a reliable way to cryopreserve small liver biopsies without affecting mitochondrial function. Our protocol will enable the transport and storage of samples, extending and facilitating mitochondrial function analysis of liver biopsies. Keywords: Cryopreservation, Mitochondria, Biopsy, Oxygen consumption rate, High-resolution respirometry, Mitochondrial function

  11. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah; PearlyTi, Joanna; Thornton, John; Brennan, Paul; Lee, Michael J.; O’Hare, Alan; Looby, Seamus [Beaumont Hospital, Department of Radiology (Ireland)

    2015-04-15

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

  12. Celiac disease or positive tissue transglutaminase antibodies in patients undergoing renal biopsies.

    Science.gov (United States)

    Nurmi, Rakel; Metso, Martti; Pörsti, Ilkka; Niemelä, Onni; Huhtala, Heini; Mustonen, Jukka; Kaukinen, Katri; Mäkelä, Satu

    2018-01-01

    An association between celiac disease and renal diseases has been suggested, but the results are controversial. To investigate the prevalence of celiac disease autoimmunity among individuals undergoing renal biopsies and to evaluate whether co-existent celiac autoimmunity influences the clinical outcome of the renal disease. The prevalence of celiac autoimmunity (previous diagnosis of celiac disease or positive tissue transglutaminase antibodies) was determined in 827 consecutive patients undergoing kidney biopsies due to clinical indications. Up to 15 years' follow-up data on kidney function and co-morbidities were obtained. Celiac autoimmunity was found in 45 (5.4%) patients. Among the IgA nephropathy patients, 8.2% of had celiac autoimmunity. At the time of kidney biopsy and after a median follow-up of 5 to 6 years, renal function measured by estimated glomerular filtration rate (eGFR) was inferior in IgA nephropathy patients with celiac autoimmunity compared to those without it (P=0.048 and P=0.022, respectively). The prevalence of celiac autoimmunity seems to be high in patients undergoing renal biopsies, especially in patients with IgA nephropathy. Such autoimmunity may be associated with worse renal function in IgA nephropathy. Hence the co-existence of celiac disease should be taken into consideration when treating patients with renal diseases. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  13. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  14. Ultrasound-assisted extraction technique for establishing selenium contents in breast cancer biopsies by Zeeman-electrothermal atomic absorption spectrometry using multi-injection

    International Nuclear Information System (INIS)

    Lavilla, I.; Mosquera, A.; Millos, J.; Cameselle, J.; Bendicho, C.

    2006-01-01

    A solid-liquid extraction method is developed to establish the contents of selenium in breast cancer biopsies. The method is based on the ultrasound-assisted extraction of selenium from pretreated biopsies prior to Se determination by atomic absorption spectrometry with longitudinal-Zeeman background correction. Fifty-one breast biopsies were collected from the Cies Hospital (Vigo, Spain), 32 of which correspond to tumor tissue and 19 to normal tissue (parenchyma). Difficulties arising from the samples analyzed, i.e. small samples mass (50-100 mg), extremely low Se contents and sample texture modification including tissue hardening due to formaldehyde preservation are addressed and overcome. High intensity sonication using a probe together with addition of hydrogen peroxide succeeded in completely extracting Se from biopsies. The multiple injection technique was useful to tackle the low Se contents present in some biopsies. The detection limit was 25 ng g -1 of Se and the precision, expressed as relative standard deviation, was less than 10%. Se contents ranged from 0.08 to 0.4 μg g -1 for parenchyma samples and from 0.09 to 0.8 μg g -1 for tumor samples. In general, Se levels in tumor biopsies were higher as compared with the adjacent normal tissue in 19 patients by a factor of up to 6. Analytical data confirmed Se accumulation in the breast tumors

  15. The clinical and pathological characteristics of nephropathies in connective tissue diseases in the Japan Renal Biopsy Registry (J-RBR).

    Science.gov (United States)

    Ichikawa, Kazunobu; Konta, Tsuneo; Sato, Hiroshi; Ueda, Yoshihiko; Yokoyama, Hitoshi

    2017-12-01

    In connective tissue diseases, a wide variety of glomerular, tubulointerstitial, and vascular lesions of the kidney are observed. Nonetheless, recent information is limited regarding renal lesions in connective tissue diseases, except in systemic lupus erythematosus (SLE). In this study, we used a nationwide database of biopsy-confirmed renal diseases in Japan (J-RBR) (UMIN000000618). In total, 20,523 registered patients underwent biopsy between 2007 and 2013; from 110 patients with connective tissue diseases except SLE, we extracted data regarding the clinico-pathological characteristics of the renal biopsy. Our analysis included patients with rheumatoid arthritis (RA) (n = 52), Sjögren's syndrome (SjS) (n = 35), scleroderma (n = 10), mixed connective tissue disease (MCTD; n = 5), anti-phospholipid syndrome (APS; n = 3), polymyositis/dermatomyositis (PM/DM; n = 1), Behçet's disease (n = 1) and others (n = 3). The clinico-pathological features differed greatly depending on the underlying disease. The major clinical diagnosis was nephrotic syndrome in RA; chronic nephritic syndrome with mild proteinuria and reduced renal function in SjS; rapidly progressive nephritic syndrome in scleroderma. The major pathological diagnosis was membranous nephropathy (MN) and amyloidosis in RA; tubulointerstitial nephritis in SjS; proliferative obliterative vasculopathy in scleroderma; MN in MCTD. In RA, most patients with nephrosis were treated using bucillamine, and showed membranous nephropathy. Using the J-RBR database, our study revealed that biopsy-confirmed cases of connective tissue diseases such as RA, SjS, scleroderma, and MCTD show various clinical and pathological characteristics, depending on the underlying diseases and the medication used.

  16. Clinical procedure for colon carcinoma tissue sampling directly affects the cancer marker-capacity of VEGF family members

    International Nuclear Information System (INIS)

    Pringels, Sarah; Van Damme, Nancy; De Craene, Bram; Pattyn, Piet; Ceelen, Wim; Peeters, Marc; Grooten, Johan

    2012-01-01

    mRNA levels of members of the Vascular Endothelial Growth Factor family (VEGF-A, -B, -C, -D, Placental Growth Factor/PlGF) have been investigated as tissue-based markers of colon cancer. These studies, which used specimens obtained by surgical resection or colonoscopic biopsy, yielded contradictory results. We studied the effect of the sampling method on the marker accuracy of VEGF family members. Comparative RT-qPCR analysis was performed on healthy colon and colon carcinoma samples obtained by biopsy (n = 38) or resection (n = 39) to measure mRNA expression levels of individual VEGF family members. mRNA levels of genes encoding the eicosanoid enzymes cyclooxygenase 2 (COX2) and 5-lipoxygenase (5-LOX) and of genes encoding the hypoxia markers glucose transporter 1 (GLUT-1) and carbonic anhydrase IX (CAIX) were included as markers for cellular stress and hypoxia. Expression levels of COX2, 5-LOX, GLUT-1 and CAIX revealed the occurrence in healthy colon resection samples of hypoxic cellular stress and a concurrent increment of basal expression levels of VEGF family members. This increment abolished differential expression of VEGF-B and VEGF-C in matched carcinoma resection samples and created a surgery-induced underexpression of VEGF-D. VEGF-A and PlGF showed strong overexpression in carcinoma samples regardless of the sampling method. Sampling-induced hypoxia in resection samples but not in biopsy samples affects the marker-reliability of VEGF family members. Therefore, biopsy samples provide a more accurate report on VEGF family mRNA levels. Furthermore, this limited expression analysis proposes VEGF-A and PlGF as reliable, sampling procedure insensitive mRNA-markers for molecular diagnosis of colon cancer

  17. Final LDRD report : development of sample preparation methods for ChIPMA-based imaging mass spectrometry of tissue samples.

    Energy Technology Data Exchange (ETDEWEB)

    Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.; Wiese-Smith, Deneille

    2007-12-01

    The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includes an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.

  18. Mercury monitoring in fish using a non-lethal tissue biopsy method

    Science.gov (United States)

    Ackerson, J; Schmitt, Christopher J.; McKee, J; Brumbaugh, W. G.

    2010-01-01

    The occurrence of mercury in fish is well-known and often occurs at levels that warrant restricted consumption by sensitive human populations. Because of this, local wildlife and health agencies have developed monitoring programs to identify the magnitude of fish contamination and changes through time. Monitoring mercury levels in fish typically requires killing fish for removal of a fillet. Recently, researchers have proposed the use of a non-lethal tissue biopsy plug method as a surrogate for analysis of the entire fillet.

  19. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Image-guided biopsy in patients with suspected ovarian carcinoma: a safe and effective technique?

    International Nuclear Information System (INIS)

    Griffin, Nyree; Grant, Lee A.; Freeman, Susan J.; Berman, Laurence H.; Sala, Evis; Jimenez-Linan, Mercedes; Earl, Helena; Ahmed, Ahmed Ashour; Crawford, Robin; Brenton, James

    2009-01-01

    In patients with suspected advanced ovarian carcinoma, a precise histological diagnosis is required before commencing neo-adjuvant chemotherapy. This study aims to determine the diagnostic accuracy and complication rate of percutaneous biopsies performed under ultrasound or computed tomography guidance. Between 2002 to 2007, 60 consecutive image-guided percutaneous biopsies were performed in patients with suspected ovarian cancer. The following variables were recorded: tissue biopsied, imaging technique, experience of operator, biopsy needle gauge, number of passes, complications, and final histology. Forty-seven patients had omental biopsies, 12 pelvic mass biopsies, and 1 para-aortic lymph node biopsy. Thirty-five biopsies were performed under ultrasound, 25 under computed tomography guidance. Biopsy needle gauges ranged from 14-20 swg with two to five passes for each patient. There were no complications. Histology was obtained in 52 (87%) patients. Percutaneous image-guided biopsy of peritoneal disease or pelvic mass is safe with high diagnostic accuracy. The large-gauge biopsy needle is as safe as the small gauge needle, but has the added value of obtaining tissue samples for immunohistochemistry and genomic studies. (orig.)

  1. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  2. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  3. [Transciptome among Mexicans: a large scale methodology to analyze the genetics expression profile of simultaneous samples in muscle, adipose tissue and lymphocytes obtained from the same individual].

    Science.gov (United States)

    Bastarrachea, Raúl A; López-Alvarenga, Juan Carlos; Kent, Jack W; Laviada-Molina, Hugo A; Cerda-Flores, Ricardo M; Calderón-Garcidueñas, Ana Laura; Torres-Salazar, Amada; Torres-Salazar, Amanda; Nava-González, Edna J; Solis-Pérez, Elizabeth; Gallegos-Cabrales, Esther C; Cole, Shelley A; Comuzzie, Anthony G

    2008-01-01

    We describe the methodology used to analyze multiple transcripts using microarray techniques in simultaneous biopsies of muscle, adipose tissue and lymphocytes obtained from the same individual as part of the standard protocol of the Genetics of Metabolic Diseases in Mexico: GEMM Family Study. We recruited 4 healthy male subjects with BM1 20-41, who signed an informed consent letter. Subjects participated in a clinical examination that included anthropometric and body composition measurements, muscle biopsies (vastus lateralis) subcutaneous fat biopsies anda blood draw. All samples provided sufficient amplified RNA for microarray analysis. Total RNA was extracted from the biopsy samples and amplified for analysis. Of the 48,687 transcript targets queried, 39.4% were detectable in a least one of the studied tissues. Leptin was not detectable in lymphocytes, weakly expressed in muscle, but overexpressed and highly correlated with BMI in subcutaneous fat. Another example was GLUT4, which was detectable only in muscle and not correlated with BMI. Expression level concordance was 0.7 (p< 0.001) for the three tissues studied. We demonstrated the feasibility of carrying out simultaneous analysis of gene expression in multiple tissues, concordance of genetic expression in different tissues, and obtained confidence that this method corroborates the expected biological relationships among LEPand GLUT4. TheGEMM study will provide a broad and valuable overview on metabolic diseases, including obesity and type 2 diabetes.

  4. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  5. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  6. Cytological Sampling Versus Forceps Biopsy During Percutaneous Transhepatic Biliary Drainage and Analysis of Factors Predicting Success

    Energy Technology Data Exchange (ETDEWEB)

    Tapping, C. R.; Byass, O. R.; Cast, J. E. I., E-mail: james.cast@hey.nhs.uk [Hull Royal Infirmary, Department of Radiology (United Kingdom)

    2012-08-15

    Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity was 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.

  7. Inflammatory cytokine expression following the use of bipolar electrocoagulation, ultracision harmonic scalpel and cold knife biopsy.

    Science.gov (United States)

    Litta, Pietro; Saccardi, Carlo; Gizzo, Salvatore; Conte, Lorena; Ambrosi, Giulia; Sissi, Claudia; Palumbo, Manlio

    2015-08-01

    Electrical surgical devices may determine tissue damage through lateral thermal spread and activation of inflammatory processes. Several tissue effects are associated with the use of different surgical instruments. The aim of the present study was to compare tissue damage following the application of cold knife biopsy, bipolar electrocoagulation and the ultracision harmonic scalpel, through the analysis of inflammatory gene mediator expression. Three fragments of the round ligament (length 0.5 cm) were obtained from 22 females who had undergone total or subtotal laparoscopic hysterectomy using three different modes of resection: Cold knife biopsy, bipolar electrocoagulation and ultracision harmonic scalpel. The tissue fragments were examined by quantitative polymerase chain reaction (qPCR) analysis of selected cytokines. Gene expression analysis demonstrated large standard deviations due to individual variability among patients and indicated variability in the concentrations of cytokines in the three different samples. The quantity of cytokine mRNA in the cold knife biopsy samples was generally greater than those obtained by other techniques. Tumor necrosis factor-α expression was significantly higher in the sample obtained with the ultracision harmonic scalpel and bipolar electrocoagulation (P=0.033) when compared with cold knife biopsy. The inflammatory response was analyzed by the quantification of gene expression through the use of qPCR. The ultracision harmonic scalpel and bipolar electrocoagulation triggered the inflammatory cascade and resulted in an increased production of cytokines compared with cold knife biopsy.

  8. Radioisotopic method for the measurement of lipolysis in small samples of human adipose tissue

    International Nuclear Information System (INIS)

    Leibel, R.L.; Hirsch, J.; Berry, E.M.; Gruen, R.K.

    1984-01-01

    To facilitate the study of adrenoreceptor response in small needle biopsy samples of human subcutaneous adipose tissue, we developed a dual radioisotopic technique for measuring lipolysis rate. Aliquots (20-75 mg) of adipose tissue fragments were incubated in a buffered albumin medium containing [ 3 H]palmitate and [ 14 C]glucose, each of high specific activity. In neutral glycerides synthesized in this system, [ 14 C]glucose is incorporated exclusively into the glyceride-glycerol moiety and 3 H appears solely in the esterified fatty acid. Alpha-2 and beta-1 adrenoreceptor activation of tissue incubated in this system does not alter rates of 14 C-labeled glyceride accumulation, but does produce a respective increase or decrease in the specific activity of fatty acids esterified into newly synthesized glycerides. This alteration in esterified fatty acid specific activity is reflected in the ratio of 14 C: 3 H in newly synthesized triglycerides extracted from the incubated adipose tissue. There is a high correlation (r . 0.90) between the 14 C: 3 H ratio in triglycerides and the rate of lipolysis as reflected in glycerol release into the incubation medium. The degree of adrenoreceptor activation by various concentrations of lipolytic and anti-lipolytic substances can be assessed by comparing this ratio in stimulated tissue to that characterizing unstimulated tissue or the incubation medium. This technique permits the study of very small, unweighed tissue biopsy fragments, the only limitation on sensitivity being the specific activity of the medium glucose and palmitate. It is, therefore, useful for serial examinations of adipose tissue adrenoreceptor dose-response characteristics under a variety of clinical circumstances

  9. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  10. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  11. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples

    International Nuclear Information System (INIS)

    O'Hagan, Joseph J; Samani, Abbas

    2009-01-01

    The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brachtherapy where tissue biomechanical modeling is involved. Another important application is interpreting nonlinear elastography images. While there has been considerable research on the measurement of the linear elastic modulus of small tissue samples, little research has been conducted for measuring parameters that characterize the nonlinear elasticity of tissues included in tissue slice specimens. This work presents hyperelastic measurement results of 44 pathological ex vivo breast tissue samples. For each sample, five hyperelastic models have been used, including the Yeoh, N = 2 polynomial, N = 1 Ogden, Arruda-Boyce, and Veronda-Westmann models. Results show that the Yeoh, polynomial and Ogden models are the most accurate in terms of fitting experimental data. The results indicate that almost all of the parameters corresponding to the pathological tissues are between two times to over two orders of magnitude larger than those of normal tissues, with C 11 showing the most significant difference. Furthermore, statistical analysis indicates that C 02 of the Yeoh model, and C 11 and C 20 of the polynomial model have very good potential for cancer classification as they show statistically significant differences for various cancer types, especially for invasive lobular carcinoma. In addition to the potential for use in cancer classification, the presented data are very important for applications such as surgery planning and virtual reality based clinician training systems where accurate nonlinear tissue response modeling is required.

  13. Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples

    Energy Technology Data Exchange (ETDEWEB)

    O' Hagan, Joseph J; Samani, Abbas [Department of Electrical and Computer Engineering, University of Western Ontario, London, ON (Canada)], E-mail: asamani@uwo.ca

    2009-04-21

    The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brachtherapy where tissue biomechanical modeling is involved. Another important application is interpreting nonlinear elastography images. While there has been considerable research on the measurement of the linear elastic modulus of small tissue samples, little research has been conducted for measuring parameters that characterize the nonlinear elasticity of tissues included in tissue slice specimens. This work presents hyperelastic measurement results of 44 pathological ex vivo breast tissue samples. For each sample, five hyperelastic models have been used, including the Yeoh, N = 2 polynomial, N = 1 Ogden, Arruda-Boyce, and Veronda-Westmann models. Results show that the Yeoh, polynomial and Ogden models are the most accurate in terms of fitting experimental data. The results indicate that almost all of the parameters corresponding to the pathological tissues are between two times to over two orders of magnitude larger than those of normal tissues, with C{sub 11} showing the most significant difference. Furthermore, statistical analysis indicates that C{sub 02} of the Yeoh model, and C{sub 11} and C{sub 20} of the polynomial model have very good potential for cancer classification as they show statistically significant differences for various cancer types, especially for invasive lobular carcinoma. In addition to the potential for use in cancer classification, the presented data are very important for applications such as surgery planning and virtual reality based clinician training systems where accurate nonlinear tissue response modeling is required.

  14. Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples

    Science.gov (United States)

    O'Hagan, Joseph J.; Samani, Abbas

    2009-04-01

    The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brachtherapy where tissue biomechanical modeling is involved. Another important application is interpreting nonlinear elastography images. While there has been considerable research on the measurement of the linear elastic modulus of small tissue samples, little research has been conducted for measuring parameters that characterize the nonlinear elasticity of tissues included in tissue slice specimens. This work presents hyperelastic measurement results of 44 pathological ex vivo breast tissue samples. For each sample, five hyperelastic models have been used, including the Yeoh, N = 2 polynomial, N = 1 Ogden, Arruda-Boyce, and Veronda-Westmann models. Results show that the Yeoh, polynomial and Ogden models are the most accurate in terms of fitting experimental data. The results indicate that almost all of the parameters corresponding to the pathological tissues are between two times to over two orders of magnitude larger than those of normal tissues, with C11 showing the most significant difference. Furthermore, statistical analysis indicates that C02 of the Yeoh model, and C11 and C20 of the polynomial model have very good potential for cancer classification as they show statistically significant differences for various cancer types, especially for invasive lobular carcinoma. In addition to the potential for use in cancer classification, the presented data are very important for applications such as surgery planning and virtual reality based clinician training systems where accurate nonlinear tissue response modeling is required.

  15. Endometrial aspiration biopsy: a non-invasive method of obtaining functional lymphoid progenitor cells and mature natural killer cells.

    LENUS (Irish Health Repository)

    McMenamin, Moya

    2012-09-01

    The aim of this study was to compare the efficacy of endometrial aspiration biopsy (EAB) with the more traditional dilatation and curettage (D&C) for the procurement of lymphoid progenitor cells and uterine natural killer (NK) populations in endometrial tissue. This prospective observational study conducted in a tertiary referral university hospital examined endometrium obtained from 32 women admitted for laparoscopic gynaecological procedures. Each participant had endometrium sampled using both EAB and D&C. Both methods were assessed as a source of uterine NK and lymphoid progenitor cells. Similar proportions of mature CD45+CD56+ NK cells (range 25.4-36.2%) and CD45+CD34+ lymphoid progenitors (range 1.2-2.0%) were found in tissue obtained using both EAB and D&C. These cells were adequate for flow cytometric analysis, magnetic bead separation and culture. Colony formation by the CD34+ population demonstrated maturational potential. Tissues obtained via endometrial biopsy and D&C are equivalent, by analysis of uterine NK and lymphoid progenitor cells. The aim of this study was to compare two methods of endometrial sampling - endometrial aspiration biopsy and traditional dilatation and curettage - for the procurement of haematopoietic stem cells and uterine natural killer (NK) populations in endometrial tissue. Thirty-two women who had gynaecological procedures in a tertiary referral hospital participated in this study and had endometrial tissue collected via both methods. Similar populations of mature NK cells and haematopoietic stem cells were found in tissue obtained using both endometrial aspiration biopsy and dilatation and curettage. Tissue obtained via endometrial aspiration biopsy was adequate for the culture and growth of haematopoietic stem cells. We conclude that tissue obtained via endometrial biopsy and dilatation and curettage is equivalent, by analysis of uterine NK and haematopoietic stem cells using flow cytometry. This has implications for further

  16. A Review of Inflammatory Processes of the Breast with a Focus on Diagnosis in Core Biopsy Samples

    Directory of Open Access Journals (Sweden)

    Timothy M. D’Alfonso

    2015-07-01

    Full Text Available Inflammatory and reactive lesions of the breast are relatively uncommon among benign breast lesions and can be the source of an abnormality on imaging. Such lesions can simulate a malignant process, based on both clinical and radiographic findings, and core biopsy is often performed to rule out malignancy. Furthermore, some inflammatory processes can mimic carcinoma or other malignancy microscopically, and vice versa. Diagnostic difficulty may arise due to the small and fragmented sample of a core biopsy. This review will focus on the pertinent clinical, radiographic, and histopathologic features of the more commonly encountered inflammatory lesions of the breast that can be characterized in a core biopsy sample. These include fat necrosis, mammary duct ectasia, granulomatous lobular mastitis, diabetic mastopathy, and abscess. The microscopic differential diagnoses for these lesions when seen in a core biopsy sample will be discussed.

  17. A Review of Inflammatory Processes of the Breast with a Focus on Diagnosis in Core Biopsy Samples.

    Science.gov (United States)

    D'Alfonso, Timothy M; Ginter, Paula S; Shin, Sandra J

    2015-07-01

    Inflammatory and reactive lesions of the breast are relatively uncommon among benign breast lesions and can be the source of an abnormality on imaging. Such lesions can simulate a malignant process, based on both clinical and radiographic findings, and core biopsy is often performed to rule out malignancy. Furthermore, some inflammatory processes can mimic carcinoma or other malignancy microscopically, and vice versa. Diagnostic difficulty may arise due to the small and fragmented sample of a core biopsy. This review will focus on the pertinent clinical, radiographic, and histopathologic features of the more commonly encountered inflammatory lesions of the breast that can be characterized in a core biopsy sample. These include fat necrosis, mammary duct ectasia, granulomatous lobular mastitis, diabetic mastopathy, and abscess. The microscopic differential diagnoses for these lesions when seen in a core biopsy sample will be discussed.

  18. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  19. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  20. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    Science.gov (United States)

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  1. Assessment of bone biopsy needles for sample size, specimen quality and ease of use

    International Nuclear Information System (INIS)

    Roberts, C.C.; Liu, P.T.; Morrison, W.B.; Leslie, K.O.; Carrino, J.A.; Lozevski, J.L.

    2005-01-01

    To assess whether there are significant differences in ease of use and quality of samples among several bone biopsy needles currently available. Eight commonly used, commercially available bone biopsy needles of different gauges were evaluated. Each needle was used to obtain five consecutive samples from a lamb lumbar pedicle. Subjective assessment of ease of needle use, ease of sample removal from the needle and sample quality, before and after fixation, was graded on a 5-point scale. The number of attempts necessary to reach a 1 cm depth was recorded. Each biopsy specimen was measured in the gross state and after fixation. The RADI Bonopty 15 g and Kendall Monoject J-type 11 g needles were rated the easiest to use, while the Parallax Core-Assure 11 g and the Bard Ostycut 16 g were rated the most difficult. Parallax Core-Assure and Kendall Monoject needles had the highest quality specimen in the gross state; Cook Elson/Ackerman 14 g and Bard Ostycut 16 g needles yielded the lowest. The MD Tech without Trap-Lok 11 g needle had the highest quality core after fixation, while the Bard Ostycut 16 g had the lowest. There was a significant difference in pre-fixation sample length between needles (P<0.0001), despite acquiring all cores to a standard 1 cm depth. Core length and width decrease in size by an average of 28% and 42% after fixation. Bone biopsy needles vary significantly in performance. Detailed knowledge of the strengths and weaknesses of different needles is important to make an appropriate selection for each individual's practice. (orig.)

  2. Study on design and cutting parameters of rotating needles for core biopsy.

    Science.gov (United States)

    Giovannini, Marco; Ren, Huaqing; Cao, Jian; Ehmann, Kornel

    2018-06-15

    Core needle biopsies are widely adopted medical procedures that consist in the removal of biological tissue to better identify a lesion or an abnormality observed through a physical exam or a radiology scan. These procedures can provide significantly more information than most medical tests and they are usually performed on bone lesions, breast masses, lymph nodes and the prostate. The quality of the samples mainly depends on the forces exerted by the needle during the cutting process. The reduction of these forces is critical to extract high-quality tissue samples. The most critical factors that affect the cutting forces are the geometry of the needle tip and its motion while it is penetrating the tissue. However, optimal needle tip configurations and cutting parameters are not well established for rotating insertions. In this paper, the geometry and cutting forces of hollow needles are investigated. The fundamental goal of this study is to provide a series of guidelines for clinicians and surgeons to properly select the optimal tip geometries and speeds. Analytical models related to the cutting angles of several needle tip designs are presented and compared. Several needle tip geometries were manufactured from a 14-gauge cannula, commonly adopted during breast biopsies. The needles were then tested at different speeds and on different phantom tissues. According to these experimental measurements recommendations were formulated for rotating needle insertions. The findings of this study can be applied and extended to several biopsy procedures in which a cannula is used to extract tissue samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    Science.gov (United States)

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  4. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  5. The effect of shot biopsy on behavior, salivary cortisol, and heart rate in slaughter pigs

    NARCIS (Netherlands)

    Geverink, NA; Ruis, MAW; Eisen, R; Lambooij, E; Blokhuis, HJ; Wiegant, VM

    This paper describes behavioral and. physiological responses of pigs to shot biopsy, an experimental method used to study muscle tissue processes or to:predict meat quality. One biopsy sample from the longissimus muscle was obtained from 23-wk-old gilts (n = 10) using a cannula connected to a

  6. RNA isolation for transcriptomics of human and mouse small skin biopsies

    Directory of Open Access Journals (Sweden)

    Breit Timo M

    2011-10-01

    Full Text Available Abstract Background Isolation of RNA from skin biopsies presents a challenge, due to the tough nature of skin tissue and a high presence of RNases. As we lacked the dedicated equipment, i.e. homogenizer or bead-beater, needed for the available RNA from skin isolation methods, we adapted and tested our zebrafish single-embryo RNA-isolation protocol for RNA isolation from skin punch biopsies. Findings We tested our new RNA-isolation protocol in two experiments: a large-scale study with 97 human skin samples, and a small study with 16 mouse skin samples. Human skin was sampled with 4.0 mm biopsy punches and for the mouse skin different punch diameter sizes were tested; 1.0, 1.5, 2.0, and 2.5 mm. The average RNA yield in human samples was 1.5 μg with an average RNA quality RIN value of 8.1. For the mouse biopsies, the average RNA yield was 2.4 μg with an average RIN value of 7.5. For 96% of the human biopsies and 100% of the mouse biopsies we obtained enough high-quality RNA. The RNA samples were successfully tested in a transcriptomics analysis using the Affymetrix and Roche NimbleGen platforms. Conclusions Using our new RNA-isolation protocol, we were able to consistently isolate high-quality RNA, which is apt for further transcriptomics analysis. Furthermore, this method is already useable on biopsy material obtained with a punch diameter as small as 1.5 mm.

  7. Primary resistance to osimertinib due to SCLC transformation: Issue of T790M determination on liquid re-biopsy.

    Science.gov (United States)

    Minari, R; Bordi, P; Del Re, M; Facchinetti, F; Mazzoni, F; Barbieri, F; Camerini, A; Comin, C E; Gnetti, L; Azzoni, C; Nizzoli, R; Bortesi, B; Rofi, E; Petreni, P; Campanini, N; Rossi, G; Danesi, R; Tiseo, M

    2018-01-01

    EGFR T790M mutation is the most common mechanism of resistance to first-/second-generation EGFR tyrosine kinase inhibitors (TKIs) in non-small cell lung cancer (NSCLC) and could be overcome by third-generation EGFR-TKIs, such as osimertinib. Liquid biopsy, a non-invasive technique used to test the presence of the resistant mutation, may help avoiding tissue re-biopsy. However, analysing only circulating-free DNA, information about other less frequent and coexisting resistance mechanisms may remain unrevealed. All patients reported in this series participated in the ASTRIS trial, a real world treatment study testing the efficacy of osimertinib (80mg os die) in advanced T790M-positive NSCLC progressed to prior EGFR-TKI. Patients were considered eligible to osimertinib if T790M positive on tissue or plasma samples. In our patients, EGFR molecular testing on blood sample was conducted with digital droplet PCR (ddPCR). We report our experience of five patients treated with osimertinib after T790M detection on liquid biopsy that presented a disease progression at first tumor assessment mediated by SCLC transformation, as evidenced at tissue re-biopsies. All patients showed low ratio T790M/activating mutation in the blood before osimertinib (lower than 0.03). For three patients, EGFR mutational analysis was T790M-negative when re-assessed by using a less sensitive method (therascreen ® ) on the same liquid biopsy sample analysed by ddPCR before osimertinib therapy. Although liquid biopsy is a relevant tool to diagnose T790M presence in NSCLC patients resistant to EGFR-TKI, in case of a low ratio T790M/activating mutation, tissue biopsy should be considered to exclude the presence of SCLC transformation and/or other concomitant resistance mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Telepathology and Optical Biopsy

    Directory of Open Access Journals (Sweden)

    Olga Ferrer-Roca

    2009-01-01

    Full Text Available The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential.

  9. The differentiation of malignant and benign human breast tissue at surgical margins and biopsy using x-ray interaction data and Bayesian classification

    International Nuclear Information System (INIS)

    Mersov, A.; Mersov, G.; Al-Ebraheem, A.; Cornacchi, S.; Gohla, G.; Lovrics, P.; Farquharson, M.J.

    2014-01-01

    Worldwide, about 1.3 million women are diagnosed with breast cancer annually with an estimated 465,000 deaths. Accordingly, there is a need for high accuracy and speed in diagnosis of lesions suspected of being cancerous. This study assesses the interaction data collected from low energy x-rays within breast tissue samples. Trace element concentrations are assessed using x-ray fluorescence, as well as electron density, and molecular structure which are examined using incoherent and coherent scatter, respectively. Our work to date has shown that such data can provide a quantitative measure of certain tissue characterising parameters and hence, through appropriate modelling, could be used to classify samples for uses such as surgical margin detection and biopsy examination. The parameters used in this study for comparing the normal and tumour tissue sample populations are: levels of elements Ca, Cu, Fe, Br, Zn, Rb, K; the area, FWHM and amplitude from peaks fitted to the coherent scatter profile that are associated with fat, fibre and water content; the ratio of the Compton and coherent scatter peak area, FWHM and amplitude from the incoherent scatter profile. The novelty of the approach to this work lies in the fact that the classification process does not rely on one source of data but combines several measurements, the data from which in this application are modelled using a method based on Bayesian classification. The reliability of the classifications was assessed by its application to diagnostically known data that was not itself included in the thresholds determination. The results of the classification of over 70 breast tissue samples will be presented in this study. Bayesian modelling was carried out using selected significant parameters for classification resulting in 71% of normal tissue samples (n=35) and 66% of tumour tissue samples (n=35) being correctly classified when using all the samples. Bayesian classification using the same variables on all

  10. Evaluation of endoscopically obtained duodenal biopsy samples from cats and dogs in an adapter-modified Ussing chamber

    Science.gov (United States)

    DeBiasio, John V.; Suchodolski, Jan S.; Newman, Shelley; Musch, Mark W.; Steiner, Jörg M.

    2014-01-01

    This study was conducted to evaluate an adapter-modified Ussing chamber for assessment of transport physiology in endoscopically obtained duodenal biopsies from healthy cats and dogs, as well as dogs with chronic enteropathies. 17 duodenal biopsies from five cats and 51 duodenal biopsies from 13 dogs were obtained. Samples were transferred into an adapter-modified Ussing chamber and sequentially exposed to various absorbagogues and secretagogues. Overall, 78.6% of duodenal samples obtained from cats responded to at least one compound. In duodenal biopsies obtained from dogs, the rate of overall response ranged from 87.5% (healthy individuals; n = 8), to 63.6% (animals exhibiting clinical signs of gastrointestinal disease and histopathological unremarkable duodenum; n = 15), and 32.1% (animals exhibiting clinical signs of gastrointestinal diseases and moderate to severe histopathological lesions; n = 28). Detailed information regarding the magnitude and duration of the response are provided. The adapter-modified Ussing chamber enables investigation of the absorptive and secretory capacity of endoscopically obtained duodenal biopsies from cats and dogs and has the potential to become a valuable research tool. The response of samples was correlated with histopathological findings. PMID:24378587

  11. Electrical biopsy of irradiated intestinal tissue with a simple electrical impedance spectroscopy system for radiation enteropathy in rats—a pilot study

    International Nuclear Information System (INIS)

    Huang, Yu-Jie; Lu, Yi-Yu; Chen, Cheng-Yu; Cheng, Kuo-Sheng; Huang, Eng-Yen

    2011-01-01

    Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable and simple EIS system based on a commercially available chip was used to assess rat intestinal tissues following irradiation. The EIS results were fitted to a resistor and capacitor electrical circuit model to solve the electrical properties of the tissue. The variation in the tissue's electrical characteristics was compared to the morphological and histological findings. From the experimental results, it was clear that the electrical properties, based on receiver operation curve analysis, demonstrated good detection performance relative to the histological changes. The electrical parameters of the tissues could be used to distinguish the tissue's status for investigation, which introduced a concept of 'electrical biopsy', and this 'electrical biopsy' approach may be used to complement histological examinations

  12. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Michael C.; Atwell, Thomas D.; King, Bernard F.; Welch, Timothy; Goenka, Ajit H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mynderse, Lance A. [Mayo Clinic, Department of Urology, Rochester, MN (United States)

    2017-08-15

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. (orig.)

  13. [Current situation and prospect of breast cancer liquid biopsy].

    Science.gov (United States)

    Zhou, B; Xin, L; Xu, L; Ye, J M; Liu, Y H

    2018-02-01

    Liquid biopsy is a diagnostic approach by analyzing body fluid samples. Peripheral blood is the most common sample. Urine, saliva, pleural effusion and ascites are also used. Now liquid biopsy is mainly used in the area of neoplasm diagnosis and treatment. Compared with traditional tissue biopsy, liquid biopsy is minimally invasive, convenient to sample and easy to repeat. Liquid biopsy mainly includes circulating tumor cells and circulating tumor DNA (ctDNA) detection. Detection of ctDNA requires sensitive and accurate methods. The progression of next-generation sequencing (NGS) and digital PCR promote the process of studies in ctDNA. In 2016, Nature published the result of whole-genome sequencing study of breast cancer. The study found 1 628 mutations of 93 protein-coding genes which may be driver mutations of breast cancer. The result of this study provided a new platform for breast cancer ctDNA studies. In recent years, there were many studies using ctDNA detection to monitor therapeutic effect and guide treatment. NGS is a promising technique in accessing genetic information and guiding targeted therapy. It must be emphasized that ctDNA detection using NGS is still at research stage. It is important to standardize ctDNA detection technique and perform prospective clinical researches. The time is not ripe for using ctDNA detection to guide large-scale breast cancer clinical practice at present.

  14. [Application of Immunohistochemistry and Immunofluorescence Staining in Detection of Phospholipase A2 Receptor on Paraffin Section of Renal Biopsy Tissue].

    Science.gov (United States)

    Dong, Hong-rui; Wang, Yan-yan; Wang, Guo-qin; Sun, Li-jun; Cheng, Hong; Chen, Yi-pu

    2015-10-01

    To evaluate the application of immunohistochemistry and fluorescence staining method in the detection of phospholipase A2 receptor (PLA2R) on paraffin section of renal biopsy tissue,and to find an accurate and fast method for the detection of PLA2R in renal tissue. The PLA2R of 193 cases were detected by immunohistochemical staining,and the antigen was repaired by the method of high pressure cooker (HPC) hot repair plus trypsin repair. The 193 samples including 139 cases of idiopathic membranous nephropathy (IMN), 15 cases of membranous lupus nephritis, 8 cases of hepatitis B virus associated membranous nephropathy, 18 cases of IgA nephropathy, and 13 cases of minimal change diseases. To compare the dyeing effects, 22 paraffin sections of renal biopsy tissue of IMN cases with positive PLA2R were stained by using 4 different. of antigen repairing,which included HPC hot repair, HPC hot repair plus trypsin repair, water bath heat repair, and water bath heat repair plus trypsin repair. To compare the dyeing effects, 15 paraffin sections of renal biopsy tissue of IMN cases with positive PLA2R were stained by using 3 different. of antigen repairing,which included water bath heat repair plus trypsin repair, protease K digestion repair, and pepsin digestion repair. In 193 cases, the positive rate of PLA2R in IMN cases was 90.6% (126/139), and the other 54 patients without IMN were negative. Twenty-two IMN patients were positive for PLA2R by using the HPC heat repair plus trypsin repaire or the water bath heat repair plus trypsin repair;while only a few cases of 22 IMN cases were positive by using the HPC hot repair alone or water bath heat repair alone. Fifteen IMN patients were positive for PLA2R by using water bath heat repair plus trypsin repair,protease K digestion repair,and pepsin digestion repair, but the distribution of positive deposits and the background were different. PLA2R immunohistochemical staining can effectively identify IMN and secondary MN. For

  15. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  16. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  17. Predicting response to primary chemotherapy: gene expression profiling of paraffin-embedded core biopsy tissue.

    Science.gov (United States)

    Mina, Lida; Soule, Sharon E; Badve, Sunil; Baehner, Fredrick L; Baker, Joffre; Cronin, Maureen; Watson, Drew; Liu, Mei-Lan; Sledge, George W; Shak, Steve; Miller, Kathy D

    2007-06-01

    Primary chemotherapy provides an ideal opportunity to correlate gene expression with response to treatment. We used paraffin-embedded core biopsies from a completed phase II trial to identify genes that correlate with response to primary chemotherapy. Patients with newly diagnosed stage II or III breast cancer were treated with sequential doxorubicin 75 mg/M2 q2 wks x 3 and docetaxel 40 mg/M2 weekly x 6; treatment order was randomly assigned. Pretreatment core biopsy samples were interrogated for genes that might correlate with pathologic complete response (pCR). In addition to the individual genes, the correlation of the Oncotype DX Recurrence Score with pCR was examined. Of 70 patients enrolled in the parent trial, core biopsies samples with sufficient RNA for gene analyses were available from 45 patients; 9 (20%) had inflammatory breast cancer (IBC). Six (14%) patients achieved a pCR. Twenty-two of the 274 candidate genes assessed correlated with pCR (p < 0.05). Genes correlating with pCR could be grouped into three large clusters: angiogenesis-related genes, proliferation related genes, and invasion-related genes. Expression of estrogen receptor (ER)-related genes and Recurrence Score did not correlate with pCR. In an exploratory analysis we compared gene expression in IBC to non-inflammatory breast cancer; twenty-four (9%) of the genes were differentially expressed (p < 0.05), 5 were upregulated and 19 were downregulated in IBC. Gene expression analysis on core biopsy samples is feasible and identifies candidate genes that correlate with pCR to primary chemotherapy. Gene expression in IBC differs significantly from noninflammatory breast cancer.

  18. Raman spectroscopy of normal oral buccal mucosa tissues: study on intact and incised biopsies

    Science.gov (United States)

    Deshmukh, Atul; Singh, S. P.; Chaturvedi, Pankaj; Krishna, C. Murali

    2011-12-01

    Oral squamous cell carcinoma is one of among the top 10 malignancies. Optical spectroscopy, including Raman, is being actively pursued as alternative/adjunct for cancer diagnosis. Earlier studies have demonstrated the feasibility of classifying normal, premalignant, and malignant oral ex vivo tissues. Spectral features showed predominance of lipids and proteins in normal and cancer conditions, respectively, which were attributed to membrane lipids and surface proteins. In view of recent developments in deep tissue Raman spectroscopy, we have recorded Raman spectra from superior and inferior surfaces of 10 normal oral tissues on intact, as well as incised, biopsies after separation of epithelium from connective tissue. Spectral variations and similarities among different groups were explored by unsupervised (principal component analysis) and supervised (linear discriminant analysis, factorial discriminant analysis) methodologies. Clusters of spectra from superior and inferior surfaces of intact tissues show a high overlap; whereas spectra from separated epithelium and connective tissue sections yielded clear clusters, though they also overlap on clusters of intact tissues. Spectra of all four groups of normal tissues gave exclusive clusters when tested against malignant spectra. Thus, this study demonstrates that spectra recorded from the superior surface of an intact tissue may have contributions from deeper layers but has no bearing from the classification of a malignant tissues point of view.

  19. Use of individual containers for prostate biopsy samples: Do we gain diagnostic performance?

    Science.gov (United States)

    Panach-Navarrete, J; García-Morata, F; Valls-González, L; Martínez-Jabaloyas, J M

    2016-05-01

    Prostate cores from transrectal biopsies are usually sent in separate vials for pathological processing. Although this is a common practice, there are controversial studies on its usefulness. We wanted to compare the rate of prostate cancer diagnosis between processing samples in 2 containers and processing them in individual containers to see if there are differences. Our secondary objective was to check the rate of diagnosis of various tumour subtypes in each of the 2 groups. A retrospective observational study was conducted of 2,601 cases of prostate biopsies. Ten cores were extracted in each biopsy. We divided the sample into 2 groups: biopsies sent in 2 containers to the department of pathology (left and right lobes) or sent in 10 (one for each cylinder), according to the different criteria used in our centre in the past. We then classified the cases according to the absence of neoplasia, insignificant tumour (involvement of just 1 cylinder, container group, and 824 were included in the 10-container group. We diagnosed a rate of 32.4% of cancers in the 2-container group and 40% in the 10-container group, a difference that was statistically significant (Pcontainer group than in the 10-container group (6.4% vs. 4.3%, respectively; P=.03). Samples with a Gleason score of 6 were diagnosed more often in the 10-container group than in the 2-container group (11.9% vs. 8.1%, respectively; P=.002). The same occurred with the Gleason score≥7 (23.8% in the 10-container group vs. 17.9% in the 2-container group; Pcontainers. Once the procedure was conducted, we also observed in our series a reduction in the diagnoses of insignificant carcinoma to the detriment of an increased diagnosis of not insignificant carcinomas. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Impact of Sodium Bicarbonate-Buffered Lidocaine on Patient Pain During Image-Guided Breast Biopsy.

    Science.gov (United States)

    Vasan, Alison; Baker, Jay A; Shelby, Rebecca A; Soo, Mary Scott C

    2017-09-01

    This randomized, double-blind controlled study evaluated the effectiveness of sodium bicarbonate-buffered lidocaine on reducing pain during imaging-guided breast biopsies. This prospective, HIPAA-compliant study randomly assigned 85 women undergoing ultrasound- or stereotactic-guided core-needle breast biopsies to receive intradermally and intraparenchymally either 1% lidocaine buffered with sodium bicarbonate (9:1 ratio) (bicarbonate study group) or 1% lidocaine alone (control group). Pain was evaluated using a 0-to-10 Likert pain scale during both intradermal and intraparenchymal anesthesia injections and during tissue sampling. Prebiopsy breast pain, anxiety, medical history, demographics, biopsy type, radiologist level of training, breast density, and lesion histology were recorded. Data were analyzed using analysis of variance and analysis of covariance. Unadjusted mean pain scores were 1.47 and 2.07 (study and control groups, respectively; P = .15) during intradermal injections, and 1.84 and 2.98 (study and control groups, respectively; P = .03) during intraparenchymal injections. Tissue sampling mean pain scores were .81 and 1.71 (study and control groups, respectively; P = .07). Moderator analyses found (1) among patients with preprocedural pain, those in the bicarbonate group experienced less intradermal injection pain (0.85 ± 1.23) than patients in the control group (2.50 ± 2.09); (2) among patients with fatty or scattered fibroglandular tissue, those in the bicarbonate group (1.35 ± 1.95) experienced less intraparenchymal injection pain than the control group (3.52 ± 3.13); and (3) during ultrasound-guided biopsies, patients in the bicarbonate group experienced less tissue-sampling pain (0.23 ± 0.63) than the control group (1.79 ± 3.05). Overall, buffering lidocaine with sodium bicarbonate significantly reduced pain during intraparenchymal injections, and additional pain reduction was found in certain patient subgroups during intradermal

  1. An Adhesive Patch-Based Skin Biopsy Device for Molecular Diagnostics and Skin Microbiome Studies.

    Science.gov (United States)

    Yao, Zuxu; Moy, Ronald; Allen, Talisha; Jansen, Burkhard

    2017-10-01

    A number of diagnoses in clinical dermatology are currently histopathologically confirmed and this image recognition-based confirmation generally requires surgical biopsies. The increasing ability of molecular pathology to corroborate or correct a clinical diagnosis based on objective gene expression, mutation analysis, or molecular microbiome data is on the horizon and would be further supported by a tool or procedure to collect samples non-invasively. This study characterizes such a tool in form of a 'bladeless' adhesive patch-based skin biopsy device. The performance of this device was evaluated through a variety of complementary technologies including assessment of sample biomass, electron microscopy demonstrating the harvesting of layers of epidermal tissue, and isolation of RNA and DNA from epidermal skin samples. Samples were obtained by application of adhesive patches to the anatomical area of interest. Biomass assessment demonstrated collection of approximately 0.3mg of skin tissue per adhesive patch and electron microscopy confirmed the nature of the harvested epidermal skin tissue. The obtained tissue samples are stored in a stable fashion on adhesive patches over a wide range of temperatures (-80oC to +60oC) and for extended periods of time (7 days or more). Total human RNA, human genomic DNA and microbiome DNA yields were 23.35 + 15.75ng, 27.72 + 20.71ng and 576.2 + 376.8pg, respectively, in skin samples obtained from combining 4 full patches collected non-invasively from the forehead of healthy volunteers. The adhesive patch skin sampling procedure is well tolerated and provides robust means to obtain skin tissue, RNA, DNA, and microbiome samples without involving surgical biopsies. The non-invasively obtained skin samples can be shipped cost effectively at ambient temperature by mail or standard courier service, and are suitable for a variety of molecular analyses of the skin microbiome as well as of keratinocytes, T cells, dendritic cells

  2. Techniques in human airway inflammation - Quantity and morphology of bronchial biopsy specimens taken by forceps of three sizes

    NARCIS (Netherlands)

    Aleva, RM; Kraan, J; Smith, M; ten Hacken, NHT; Postma, DS; Timens, W

    Background: In recent years, fiberoptic bronchoscopy has been introduced successfully in the research of bronchial asthma. Bronchial biopsy specimens obtained by this procedure are small, and an optimal biopsy technique is necessary to obtain high-quality tissue samples, as sufficient length of

  3. Grading of shoulder ulcerations in sows by biopsies

    DEFF Research Database (Denmark)

    Jensen, Henrik Elvang; Dahl-Pedersen, Kirstin; Barington, Krisitane

    2014-01-01

    legislation, stating that sows with shoulder ulcers grade 3 or 4 must be kept loose and have access to soft bedding. Thus, the aim of the present study was to evaluate if biopsies from the center of a shoulder ulcer can be used to point out animals for which an intervention must be initiated. Postmortem......, a punch biopsy was sampled from the center of the ulceration or from the tissue overlaying the tuber spina scapula. Afterward, the shoulders were cross-sectioned and evaluated grossly and histologically (“gold standard”). In total, 121 shoulders were included in the study, and the diagnostic value...... of a punch biopsy in grading shoulder ulcerations was evaluated. The results showed a sensitivity of 0.78, a specificity of 0.98, a positive likelihood ratio of 38.36, and a negative likelihood ratio of 0.22. The agreement between the cross-section evaluation and the punch biopsy was found to be 0...

  4. Microarray analysis in clinical oncology: pre-clinical optimization using needle core biopsies from xenograft tumors

    International Nuclear Information System (INIS)

    Goley, Elizabeth M; Anderson, Soni J; Ménard, Cynthia; Chuang, Eric; Lü, Xing; Tofilon, Philip J; Camphausen, Kevin

    2004-01-01

    DNA microarray profiling performed on clinical tissue specimens can potentially provide significant information regarding human cancer biology. Biopsy cores, the typical source of human tumor tissue, however, generally provide very small amounts of RNA (0.3–15 μg). RNA amplification is a common method used to increase the amount of material available for hybridization experiments. Using human xenograft tissue, we sought to address the following three questions: 1) is amplified RNA representative of the original RNA profile? 2) what is the minimum amount of total RNA required to perform a representative amplification? 3) are the direct and indirect methods of labeling the hybridization probe equivalent? Total RNA was extracted from human xenograft tissue and amplified using a linear amplification process. RNA was labeled and hybridized, and the resulting images yielded data that was extracted into two categories using the mAdb system: 'all genes' and 'outliers'. Scatter plots were generated for each slide and Pearson Coefficients of correlation were obtained. Results show that the amplification of 5 μg of total RNA yields a Pearson Correlation Coefficient of 0.752 (N = 6,987 genes) between the amplified and total RNA samples. We subsequently determined that amplification of 0.5 μg of total RNA generated a similar Pearson Correlation Coefficient as compared to the corresponding original RNA sample. Similarly, sixty-nine percent of total RNA outliers were detected with 5 μg of amplified starting RNA, and 55% of outliers were detected with 0.5 μg of starting RNA. However, amplification of 0.05 μg of starting RNA resulted in a loss of fidelity (Pearson Coefficient 0.669 between amplified and original samples, 44% outlier concordance). In these studies the direct or indirect methods of probe labeling yielded similar results. Finally, we examined whether RNA obtained from needle core biopsies of human tumor xenografts, amplified and indirectly

  5. VALIDITY OF CORE NEEDLE BIOPSY IN THE HISTOPATHOLOGICAL VERIFICATION OF PAROTID GLAND LESIONS

    Directory of Open Access Journals (Sweden)

    Oroz Aleksandar

    2016-07-01

    Full Text Available Background and purpose: An adequate diagnosis of a parotid gland enlargement is crucial for an appropriate treatment. The aim of the study was to evaluate effectiveness and minimal invasiveness of diagnostic procedures of core-needle biopsy. Materials and Methods: This study involved 67 patients, aged 40 to 90 years, with a tumor mass in the submandibular and parotid region. Method used for taking samples of pathological masses was BD Disposable guillotine spring-loaded needle for biopsies on soft tissues. Final diagnoses were established on the basis of surgical-pathological results in 67 cases, and on the basis of histopathological analysis of core-biopsy samples. Results: Compared with results of surgical biopsy, core-needle biopsy had sensitivity of 100% in differentiating benign from malignant lesions and in setting up an adequate diagnosis. Its positive predictive values were 100% in diagnosing malignancy. There were found 28 non-malignant and 39 malignant lesions with fewer disadvantages for patients.

  6. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  7. Practical guidelines for ultrasound-guided core needle biopsy of soft-tissue lesions: Transformation from beginner to specialist

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Yoon; Chung, Hye Won; Oh, Tack Sun; Lee, Jong Seok [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasound-guided core needle biopsy (US-CNB) is an important step in the diagnosis of musculoskeletal soft-tissue lesions. To maximize efficacy and minimize the complications of US-CNB, it is critical to collaborate with a multidisciplinary team and to understand the particular considerations of US-CNB for these lesions. The purpose of this article is to provide a systematic review and step-by-step tips for using US-CNB to diagnose musculoskeletal soft-tissue lesions.

  8. Instant Transport Media for Biopsied Soft Tissue Specimens: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Shankargouda Patil

    2015-01-01

    Full Text Available Background. Formalin, a traditionally preferred fixative in the field of pathology, has restricted usage in private settings. Since its toxicity violates the Occupational Safety and Health Administration regulations, an eco-friendly alternative would be the need of the hour. Hence an instant media which is economical and nontoxic and enables easy transport of biopsied soft tissue specimens in its original state is of vital importance. Materials and Methods. Commercially available fresh goat buccal mucosa specimens were sliced into smaller bits of equal dimensions and placed in six different containers containing 20% honey, 30% jaggery, milk, and ice for 1 hr, 6 hours, 12 hours, and 24 hours each with formalin as a positive control. After the set time interval, the specimens were fixed in 10% buffered formalin for 24 hours followed by routine processing and staining. The histologic interpretations were a blinded procedure and evaluated by two experts. Results were statistically analysed. Results. 30% jaggery proved to be an ideal transport media showing high quality preservation after 24 hours. 20% honey and ice showed optimal tissue preservation up to 6 hours following which quality deteriorated. Tissues transported in milk showed poor preservation. Conclusion. 30% jaggery can be endorsed in routine histopathological analysis as a transport media.

  9. Method to characterize inorganic particulates in lung tissue biopsies using field emission scanning electron microscopy

    Science.gov (United States)

    Lowers, Heather; Breit, George N.; Strand, Matthew; Pillers, Renee M.; Meeker, Gregory P.; Todorov, Todor I.; Plumlee, Geoffrey S.; Wolf, Ruth E.; Robinson, Maura; Parr, Jane; Miller, Robert J.; Groshong, Steve; Green, Francis; Rose, Cecile

    2018-01-01

    Humans accumulate large numbers of inorganic particles in their lungs over a lifetime. Whether this causes or contributes to debilitating disease over a normal lifespan depends on the type and concentration of the particles. We developed and tested a protocol for in situ characterization of the types and distribution of inorganic particles in biopsied lung tissue from three human groups using field emission scanning electron microscopy (FE-SEM) combined with energy dispersive spectroscopy (EDS). Many distinct particle types were recognized among the 13 000 particles analyzed. Silica, feldspars, clays, titanium dioxides, iron oxides and phosphates were the most common constituents in all samples. Particles were classified into three general groups: endogenous, which form naturally in the body; exogenic particles, natural earth materials; and anthropogenic particles, attributed to industrial sources. These in situ results were compared with those using conventional sodium hypochlorite tissue digestion and particle filtration. With the exception of clays and phosphates, the relative abundances of most common particle types were similar in both approaches. Nonetheless, the digestion/filtration method was determined to alter the texture and relative abundances of some particle types. SEM/EDS analysis of digestion filters could be automated in contrast to the more time intensive in situ analyses.

  10. Melanoma-specific marker expression in skin biopsy tissues as a tool to facilitate melanoma diagnosis.

    Science.gov (United States)

    Alexandrescu, Doru T; Kauffman, C Lisa; Jatkoe, Timothy A; Hartmann, Dan P; Vener, Tatiana; Wang, Haiying; Derecho, Carlo; Rajpurohit, Yashoda; Wang, Yixin; Palma, John F

    2010-07-01

    Diagnosis of cutaneous melanoma requires accurate differentiation of true malignant tumors from highly atypical lesions, which lack the capacity to develop uncontrolled proliferation and to metastasize. We used melanoma markers from previous work to differentiate benign and atypical lesions from melanoma using paraffin-embedded tissue. This critical step in diagnosis generates the most uncertainty and discrepancy between dermatopathologists. A total of 193 biopsy tissues were selected: 47 melanomas, 48 benign nevi, and 98 atypical/suspicious, including 48 atypical nevi and 50 melanomas as later assigned by expert dermatopathologists. Performance for SILV, GDF15, and L1CAM normalized to TYR in unequivocal melanoma versus benign nevi resulted in an area under the curve (AUC) of 0.94, 0.67, and 0.5, respectively. SILV also differentiated atypical cases classified as melanoma from atypical nevi with an AUC=0.74. Furthermore, SILV showed a significant difference between suspicious melanoma and each suspicious atypia group: melanoma versus severe atypia and melanoma versus moderate atypia had P-values of 0.0077 and 0.0009, respectively. SILV showed clear discrimination between melanoma and benign unequivocal cases as well as between different atypia subgroups in the group of suspicious samples. The role and potential utility of this molecular assay as an adjunct to the morphological diagnosis of melanoma are discussed.

  11. Risk of disseminated intravascular coagulation in patients undergoing US-guided transperineal prostatic biopsy

    International Nuclear Information System (INIS)

    Stella, M.S.; Comparato, D.; Camici, M.; Evangelisti, L.; Gaudio, V.; De Negri, F.; Talarico, L.; Giusti, C.; Morelli, G.

    1991-01-01

    Disseminated intravascular coagulation (DIC) is a severe life-threatening acute bleeding disorder. Traumatized tissues, tumors, necrotic tissues, or bacterial endotoxines release similar material in the blood to the tissutal factors activating the coagulation cascade. This preliminary study was aimed at verifying the risk of DIV in patients undergoing US-guided transperineal prostatic biopsy with Chiba and Tru-Cut needles. To evaluate the activation degree of coagulation factors in the circulation, the authors measured the concentrations of urinary fibrin degradation products in 10 patients undergoing US-guided transperineal prostatic biopsy, both before and after biopsy, every second hour, for 24 hours. Every tube of urine sample contained soya bean trypsin inhibitor and bovine thrombin to prevent any further fibrin degradation during incubation period for the possible presence of blood in urine samples. The results showed that 7/10 patients had marked increase in urinary fibrin degradation product levels (up to 800 XXXX%), with a 3-phase trend: early peak after 2-6 hours, middle peak after 6-14 hours, and late peak after 18-24 hours, which proved the activation of the coagulation cascade

  12. Comparative cost-effectiveness of fine needle aspiration biopsy versus image-guided biopsy, and open surgical biopsy in the evaluation of breast cancer in the era of Affordable Care Act: a changing landscape.

    Science.gov (United States)

    Masood, Shahla; Rosa, Marilin; Kraemer, Dale F; Smotherman, Carmen; Mohammadi, Amir

    2015-08-01

    Proven as a time challenged and cost-effective sampling procedure, the use of FNAB has still remained controversial among the scientific community. Currently, other minimally invasive sampling procedures such as ultrasound guided fine needle aspiration biopsy (US-FNAB) and image guided core needle biopsy (IG-CNB) have become the preferred sampling procedures for evaluation of breast lesions. However, changes in the medical economy and the current growing emphasis on cost containment in the era of the Affordable Care Act make it necessary to stimulate a renewed interest in the use of FNAB as the initial diagnostic sampling procedure. This study was designed to define the changing trend in the practice of tissue sampling during the last several years, and to assess the comparative effectiveness and appropriateness of the procedure of choice for breast cancer diagnosis. After Institutional Review Board (IRB) approval, the computer database of the Pathology Department, University of Florida, College of Medicine-Jacksonville at UF Health was retrospectively searched to identify all breast biopsy pathology reports issued during the period of January 2004 to December 2011. The inclusion criteria were all women that underwent any of the following biopsy types: FNAB, US-FNAB, IG-CNB, and surgical biopsy (SB). Diagnostic procedures were identified using current procedural terminology (CPT) codes recorded on claims from the UF Health Jacksonville patient accounting application files. The data obtained was used to determine which technique has the best cost-effectiveness in the diagnosis of breast cancer. The outcome variable for this project was a positive breast cancer diagnosis resulting from these methodologies. The predictor variable was the biopsy type used for sampling. The rate of cancer detection for each procedure was also determined. Among the four groups of procedures compared, the lower cost was attributed to FNAB, followed by US-FNAB, and SB. IG-CNB was the most

  13. The diagnosis of MR and CT scan for myofascitis of connective tissue disease: comparison with biopsy examination

    International Nuclear Information System (INIS)

    Xu Jianrong; Zhou Yan; Chai Weimin; Yao Qiuying; Li Lei; Li Lan; Li Zhengyang

    2002-01-01

    Objective: To evaluate the utility of MRI, CT and biopsy examinations in detecting myofascitis lesions of connective tissue disease. Methods: The study group consisted of 22 patients proven by clinical features and laboratory examination, including 8 cases of dermatomyositis (DM), 12 cases of polymyositis (PM), and 2 cases of eosinophilic fascitis. All patients received CT scan, SE-T 1 WI, SE-T 2 WI, SPIR, and CT guiding biopsy at the thigh region. Results: Biopsy detected muscular diseases in 17 cases and fascitis in 5 cases. MRI detected muscular diseases in 14 and fascitis in 9. CT detected muscular diseases in 5 and fascitis in 9. Myositis, amyotrophy, and fascitis may be alone or united in one case. Myositis (9 cases) appeared as low signal on T 1 WI and high signal on T 2 WI or SPIR. Amyotrophy (9 cases) presented hyperintensity on both T 1 WI and T 2 WI. SPIR was more sensitive in detecting myositis than CT and T 1 WI, P < 0.05. Myositis was more frequent in cases with DM(6/8) than in cases with PM (3/12), P < 0.05. Also, myositis was more frequently encountered in active phase (7/11) than in quiescent phase (2/11). Conclusion: MRI and CT appear to be valuable in quantitatively and qualitatively estimating myofascitis of connective tissue diseases

  14. Optical coherence elastography (OCE) as a method for identifying benign and malignant prostate biopsies

    Science.gov (United States)

    Li, Chunhui; Guan, Guangying; Ling, Yuting; Lang, Stephen; Wang, Ruikang K.; Huang, Zhihong; Nabi, Ghulam

    2015-03-01

    Objectives. Prostate cancer is the most frequently diagnosed malignancy in men. Digital rectal examination (DRE) - a known clinical tool based on alteration in the mechanical properties of tissues due to cancer has traditionally been used for screening prostate cancer. Essentially, DRE estimates relative stiffness of cancerous and normal prostate tissue. Optical coherence elastography (OCE) are new optical imaging techniques capable of providing cross-sectional imaging of tissue microstructure as well as elastogram in vivo and in real time. In this preliminary study, OCE was used in the setting of the human prostate biopsies ex vivo, and the images acquired were compared with those obtained using standard histopathologic methods. Methods. 120 prostate biopsies were obtained by TRUS guided needle biopsy procedures from 9 patients with clinically suspected cancer of the prostate. The biopsies were approximately 0.8mm in diameter and 12mm in length, and prepared in Formalin solution. Quantitative assessment of biopsy samples using OCE was obtained in kilopascals (kPa) before histopathologic evaluation. The results obtained from OCE and standard histopathologic evaluation were compared provided the cross-validation. Sensitivity, specificity, and positive and negative predictive values were calculated for OCE (histopathology was a reference standard). Results. OCE could provide quantitative elasticity properties of prostate biopsies within benign prostate tissue, prostatic intraepithelial neoplasia, atypical hyperplasia and malignant prostate cancer. Data analysed showed that the sensitivity and specificity of OCE for PCa detection were 1 and 0.91, respectively. PCa had significantly higher stiffness values compared to benign tissues, with a trend of increasing in stiffness with increasing of malignancy. Conclusions. Using OCE, microscopic resolution elastogram is promising in diagnosis of human prostatic diseases. Further studies using this technique to improve the

  15. Development of a real-time PCR to detect Demodex canis DNA in different tissue samples.

    Science.gov (United States)

    Ravera, Ivan; Altet, Laura; Francino, Olga; Bardagí, Mar; Sánchez, Armand; Ferrer, Lluís

    2011-02-01

    The present study reports the development of a real-time polymerase chain reaction (PCR) to detect Demodex canis DNA on different tissue samples. The technique amplifies a 166 bp of D. canis chitin synthase gene (AB 080667) and it has been successfully tested on hairs extracted with their roots and on formalin-fixed paraffin embedded skin biopsies. The real-time PCR amplified on the hairs of all 14 dogs with a firm diagnosis of demodicosis and consistently failed to amplify on negative controls. Eleven of 12 skin biopsies with a morphologic diagnosis of canine demodicosis were also positive. Sampling hairs on two skin points (lateral face and interdigital skin), D. canis DNA was detected on nine of 51 healthy dogs (17.6%) a much higher percentage than previously reported with microscopic studies. Furthermore, it is foreseen that if the number of samples were increased, the percentage of positive dogs would probably also grow. Moreover, in four of the six dogs with demodicosis, the samples taken from non-lesioned skin were positive. This finding, if confirmed in further studies, suggests that demodicosis is a generalized phenomenon in canine skin, due to proliferation of local mite populations, even though macroscopic lesions only appear in certain areas. The real-time PCR technique to detect D. canis DNA described in this work is a useful tool to advance our understanding of canine demodicosis.

  16. Screening for Helicobacter pylori in Idiopathic Pulmonary Fibrosis Lung Biopsies.

    Science.gov (United States)

    Kreuter, Michael; Kirsten, Detlef; Bahmer, Thomas; Penzel, Roland; Claussen, Martin; Ehlers-Tenenbaum, Svenja; Muley, Thomas; Palmowski, Karin; Eichinger, Monika; Leider, Marta; Herth, Felix J F; Rabe, Klaus F; Bittmann, Iris; Warth, Arne

    2016-01-01

    Increasing evidence suggests a role of gastro-oesophageal reflux (GER) in idiopathic pulmonary fibrosis (IPF) pathogenesis. Recently, an association between serum Helicobacter pylori (HP) antibody positivity and more severe disease was described, but HP has not been directly analysed in lung tissue so far. To investigate the presence of HP in the lung tissue of IPF patients. Two tertiary interstitial lung disease care centre databases were screened for available lung biopsy material from IPF patients. Clinical and radiological data, including presence of GER and antiacid medication, were evaluated. HP-specific PCR was carried out on the IPF lung biopsy specimens. A total of 39 IPF patients were included, of whom 85% were male. The patients' median age was 66 years, their vital capacity was 79% predicted, and their diffusing capacity for carbon monoxide was 53% predicted. In all, 82% of the lung biopsies were surgical and 18% transbronchial. Comorbidities were GER disease in 23% (n = 9), sleep apnoea in 13% (n = 5) and hiatal hernia in 38% of the cases (n = 15). Proton pump inhibitors were prescribed at the time of biopsy in 21% of the cases (n = 9). After a median follow-up of 25 months (range 6-69), there were 1 death, 1 lung transplantation and 8 acute exacerbations without relevant differences between the GER and non-GER subgroups. HP DNA was not detected in any of the lung tissue samples. The fact that no HP DNA was detected in the lung tissues calls into question the proposed relevance of HP to the direct pathogenesis of IPF. © 2015 S. Karger AG, Basel.

  17. Is there a role for anterior zone sampling as part of saturation trans-rectal ultrasound guided prostate biopsy?

    Science.gov (United States)

    Cole, Eric; Margel, David; Greenspan, Michael; Shayegan, Bobby; Matsumoto, Edward; Fischer, Marc A; Patlas, Michael; Daya, Dean; Pinthus, Jehonathan H

    2014-05-03

    The prostatic anterior zone (AZ) is not targeted routinely by TRUS guided prostate biopsy (TRUS-Pbx). MRI is an accurate diagnostic tool for AZ tumors, but is often unavailable due to cost or system restrictions. We examined the diagnostic yield of office based AZ TRUS-Pbx. 127 men at risk for AZ tumors were studied: Patients with elevated PSA and previous extended negative TRUS-Pbx (group 1, n = 78) and actively surveyed low risk prostate cancer patients (group 2, n = 49). None of the participants had a previous AZ biopsy. Biopsy template included suspicious ultrasonic areas, 16 peripheral zone (PZ), 4 transitional zone (TZ) and 6 AZ cores. All biopsies were performed by a single urologist under local peri-prostatic anaesthetic, using the B-K Medical US System, an end-firing probe 4-12 MHZ and 18 ga/25 cm needle. All samples were reviewed by a single specialized uro-pathologist. Multivariate analysis was used to detect predictors for AZ tumors accounting for age, PSA, PSA density, prostate volume, BMI, and number of previous biopsies. Median PSA was 10.4 (group 1) and 7.3 (group 2). Age (63.9, 64.5), number of previous biopsies (1.5) and cores (17.8, 21.3) and prostate volume (56.4 cc, 51 cc) were similar for both groups. The overall diagnostic yield was 34.6% (group 1) and 85.7% (group 2). AZ cancers were detected in 21.8% (group 1) and 34.7% (group 2) but were rarely the only zone involved (1.3% and 4.1% respectively). Gleason ≥ 7 AZ cancers were often accompanied by equal grade PZ tumors. In multivariate analysis only prostate volume predicted for AZ tumors. Patients detected with AZ tumors had significantly smaller prostates (36.9 cc vs. 61.1 cc p < 0.001). Suspicious AZ ultrasonic findings were uncommon (6.3%). TRUS-Pbx AZ sampling rarely improves the diagnostic yield of extended PZ sampling in patients with elevated PSA and previous negative biopsies. In low risk prostate cancer patients who are followed by active surveillance, AZ sampling changes risk

  18. The single-biopsy approach in determining protein synthesis in human slow-turning-over tissue: use of flood-primed, continuous infusion of amino acid tracer

    DEFF Research Database (Denmark)

    Holm, Lars; Reitelseder, Søren; Dideriksen, Kasper

    2014-01-01

    Muscle protein synthesis (MPS) rate is determined conventionally by obtaining two or more tissue biopsies during a primed, continuous infusion of a stable isotopically labeled amino acid. The purpose of the present study was to test whether tracer priming given as a flooding dose, thereby securing....... In conclusion, the flood-primed, continuous infusion protocol using phenylalanine as tracer can validly be used to measure the protein synthesis rate in human in vivo experiments by obtaining only a single tissue biopsy after a prolonged infusion period....

  19. Transrectal real-time tissue elastography targeted biopsy coupled with peak strain index improves the detection of clinically important prostate cancer.

    Science.gov (United States)

    Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi

    2017-07-01

    The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.

  20. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  1. Efficacy and Complications of Ultrasound-Guided Percutaneous Renal Biopsy Using Automatic Biopsy Gun in Pediatric Diffuse Renal Disease: Analysis of 97 Cases

    International Nuclear Information System (INIS)

    Han, Seung Min; Chung, Tae Woong; Yoon, Woong

    2007-01-01

    To evaluate the diagnostic efficacy and complications of ultrasound-guided percutaneous renal biopsy using automatic biopsy gun in patients with pediatric diffuse renal disease. Using an 18G automatic biopsy gun, biopsies were performed on 97 pediatric patients with clinically suspicious diffuse renal disease. The acquired tissue specimens were analyzed by photomicroscopy, immunofluorescence, and electron microscopy to support the diagnosis. In the 97 biopsies, the success of the histologic diagnosis, number of glomeruli, and complication rates were retrospectively evaluated by analyzing the variable exams and clinical records. Adequate tissue for histologic diagnosis was obtained in 91 of 97 biopsies (94%) and the mean number of glomeruli was 9.6. Complications such as minute pain, gross hematuria, and small perirenal hematoma presented in 22 of the 97 biopsies (23%), all of which either improved within 5-72 hours or did not need specific treatment. Ultrasound-guided percutaneous renal biopsy using 18G automatic biopsy gun is an effective and safe method for the histologic diagnosis of pediatric diffuse renal disease without any major complication

  2. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  3. Direct measurement of catalase activity in living cells and tissue biopsies.

    Science.gov (United States)

    Scaglione, Christine N; Xu, Qijin; Ramanujan, V Krishnan

    2016-01-29

    Spatiotemporal regulation of enzyme-substrate interactions governs the decision-making steps in biological systems. Enzymes, being functional units of every living cell, contribute to the macromolecular stability of cell survival, proliferation and hence are vital windows to unraveling the biological complexity. Experimental measurements capturing this dynamics of enzyme-substrate interactions in real time add value to this understanding. Furthermore these measurements, upon validation in realistic biological specimens such as clinical biopsies - can further improve our capability in disease diagnostics and treatment monitoring. Towards this direction, we describe here a novel, high-sensitive measurement system for measuring diffusion-limited enzyme-substrate kinetics in real time. Using catalase (enzyme) and hydrogen peroxide (substrate) as the example pair, we demonstrate that this system is capable of direct measurement of catalase activity in vitro and the measured kinetics follows the classical Michaelis-Menten reaction kinetics. We further demonstrate the system performance by measuring catalase activity in living cells and in very small amounts of liver biopsies (down to 1 μg total protein). Catalase-specific enzyme activity is demonstrated by genetic and pharmacological tools. Finally we show the clinically-relevant diagnostic capability of our system by comparing the catalase activities in liver biopsies from young and old mouse (liver and serum) samples. We discuss the potential applicability of this system in clinical diagnostics as well as in intraoperative surgical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. A cutting biopsy needle for the histological diagnosis of abdominal and retroperitoneal masses

    International Nuclear Information System (INIS)

    Hauenstein, K.H.; Wimmer, B.; Freudenberg, N.; Freiburg Univ.

    1985-01-01

    A new cutting biopsy needle has been used to obtain histologically useful material while causing the minimum of trauma. It permits biopsies of organs, but its small external diameter of 0.8 or 0.95 mm makes it possible to carry out transperitoneal puncture of the stomach, colon or liver and of the retroperitoneal space, using a ventral approach. Tissue samples were obtained in 96% of 63 patients. The risk of complications is no higher than for conventional needles used for cytology. The accuracy with which the material can be obtained is therefore the most important problem. The position of the area to be biopsied should determine whether the biopsy is to be aided by sonography or CT. Biopsies of organs can be appropriately carried out under ultrasound control, but processes in the pelvis and in retroperitoneal-paravertebral and extra-peritoneal positions are best biopsied under CT control. (orig.) [de

  5. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  6. Optical characterization of thin female breast biopsies based on the reduced scattering coefficient

    International Nuclear Information System (INIS)

    Garofalakis, A; Zacharakis, G; Filippidis, G; Sanidas, E; Tsiftsis, D D; Stathopoulos, E; Kafousi, M; Ripoll, J; Papazoglou, T G

    2005-01-01

    One of the main goals in optical characterization of biopsies is to discern between tissue types. Usually, the theory used for deriving the optical properties of such highly scattering media is based on the diffusion approximation. However, biopsies are usually small in size compared to the transport mean free path and thus cannot be treated with standard diffusion theory. To account for this, an improved theory was developed, by the authors, that can correctly describe light propagation in small geometries (Garofalakis et al 2004 J. Opt. A: Pure Appl. Opt. 6 725-35). The theory's limit was validated by both Monte Carlo simulations and experiments performed on tissue-like phantoms, and was found to be two transport mean free paths. With the aid of this theory, we have characterized 59 samples of breast tissue including cancerous samples by retrieving their reduced scattering coefficients from time-resolved transmission data. The mean values for the reduced scattering coefficients of the normal and the tumour tissue were measured to be 9.7 ± 2.2 cm -1 and 10.8 ± 1.8 cm -1 , respectively. The correlation with age was also investigated

  7. Cryobiopsy: Should This Be Used in Place of Endobronchial Forceps Biopsies?

    Directory of Open Access Journals (Sweden)

    Edmundo R. Rubio

    2013-01-01

    Full Text Available Forceps biopsies of airway lesions have variable yields. The yield increases when combining techniques in order to collect more material. With the use of cryotherapy probes (cryobiopsy larger specimens can be obtained, resulting in an increase in the diagnostic yield. However, the utility and safety of cryobiopsy with all types of lesions, including flat mucosal lesions, is not established. Aims. Demonstrate the utility/safety of cryobiopsy versus forceps biopsy to sample exophytic and flat airway lesions. Settings and Design. Teaching hospital-based retrospective analysis. Methods. Retrospective analysis of patients undergoing cryobiopsies (singly or combined with forceps biopsies from August 2008 through August 2010. Statistical Analysis. Wilcoxon signed-rank test. Results. The comparative analysis of 22 patients with cryobiopsy and forceps biopsy of the same lesion showed the mean volumes of material obtained with cryobiopsy were significantly larger (0.696 cm3 versus 0.0373 cm3, P=0.0014. Of 31 cryobiopsies performed, one had minor bleeding. Cryopbiopsy allowed sampling of exophytic and flat lesions that were located centrally or distally. Cryobiopsies were shown to be safe, free of artifact, and provided a diagnostic yield of 96.77%. Conclusions. Cryobiopsy allows safe sampling of exophytic and flat airway lesions, with larger specimens, excellent tissue preservation and high diagnostic accuracy.

  8. Controlling the Stormram 2: An MRI-compatible Robotic System for Breast Biopsy

    NARCIS (Netherlands)

    Abdelaziz, Mohamed E.M.K.; Groenhuis, Vincent; Veltman, Jeroen; Siepel, Françoise Jeanette; Stramigioli, Stefano

    2017-01-01

    Breast cancer is the most frequently life-threatening diagnosed type of cancer among women. Early and accurate diagnosis by acquiring a tissue sample using biopsy techniques is essential. However, small lesions only visible by MRI are often missed in standard methods, indicating the need for a

  9. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  10. Upright stereotactic vacuum-assisted needle biopsy of suspicious breast microcalcification

    International Nuclear Information System (INIS)

    Sim, L. S. J.; Kei, P. L.

    2008-01-01

    Full text: Stereotactic core needle biopsy is a useful technique for evaluation of suspicious breast microcalcifications. Thf development of the 11-G vacuum-assisted biopsy system offers another method of minimally invasive biopsy carried out on a conventional mammography unit. We evaluate its usefulness, efficacy and safety in Asian women.. Vacuum-assisted biopsy was carried out through the lateral approach using an add-on stereotactic device attached to a mammography unit. One hundred and five lesions were sampled in 97 patients. Excisional biopsy was subsequently Carried out for diagnosis of atypical ductal hyperplasia or carcinoma in high-risk patients. Patients with benign diagnosis underwent mammographic follow up. The technical success rate was 97%. An average of 13.5 tissue cores were retrieved for each lesion. The histopathological result obtained from mammotome was benign in 84.8% and malignant in 15.2%. The benign microcalcifications were predominantly fibrocystic change (n = 42)| whereas the malignant microcalcifications included ductal carcinoma in situ (n = 15) and invasive carcinoma (n = 1). Twenty-two patients underwent subsequent open surgical biopsy but no underestimation of disease was seen. Only two patients had vasovagal syncope and three others felt unwell during the biopsy. Nine patients had small haema-1 tomas, which resolved spontaneously. Vacuum-assisted biopsy carried out on an upright stereotactic mammography] unit is a safe and effective method for evaluation of suspicious microcalcifications.

  11. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  12. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  13. Molecular sexing of tucuxi dolphins (Sotalia guianensis and Sotalia fluviatilis using samples from biopsy darting and decomposed carcasses

    Directory of Open Access Journals (Sweden)

    Haydée A. Cunha

    2007-01-01

    Full Text Available We tested the zinc-finger sex chromosome-linked genes Zfx/Zfy and the sex-determining region Y (Sry genes for gender determination of biopsy samples from marine and riverine tucuxi dolphins (Sotalia guianensis and S. fluviatilis. We also evaluated the performance of these genes with decomposed carcasses, for which sexing cannot rely on the direct examination of the reproductive tract. Both systems proved reliable for sexing 46 fresh and decomposed samples, making them especially useful when biopsy darting is coupled with photo-identification studies.

  14. Osteochondral Biopsy Analysis Demonstrates That BST-CarGel Treatment Improves Structural and Cellular Characteristics of Cartilage Repair Tissue Compared With Microfracture

    Science.gov (United States)

    Méthot, Stéphane; Changoor, Adele; Tran-Khanh, Nicolas; Hoemann, Caroline D.; Stanish, William D.; Restrepo, Alberto; Shive, Matthew S.; Buschmann, Michael D.

    2016-01-01

    Objective The efficacy and safety of BST-CarGel, a chitosan-based medical device for cartilage repair, was compared with microfracture alone at 1 year during a multicenter randomized controlled trial (RCT) in the knee. The quality of repair tissue of osteochondral biopsies collected from a subset of patients was compared using blinded histological assessments. Methods The international RCT evaluated repair tissue quantity and quality by 3-dimensional quantitative magnetic resonance imaging as co-primary endpoints at 12 months. At an average of 13 months posttreatment, 21/41 BST-CarGel and 17/39 microfracture patients underwent elective second look arthroscopies as a tertiary endpoint, during which ICRS (International Cartilage Repair Society) macroscopic scoring was carried out, and osteochondral biopsies were collected. Stained histological sections were evaluated by blinded readers using ICRS I and II histological scoring systems. Collagen organization was evaluated using a polarized light microscopy score. Results BST-CarGel treatment resulted in significantly better ICRS macroscopic scores (P = 0.0002) compared with microfracture alone, indicating better filling, integration, and tissue appearance. Histologically, BST-CarGel resulted in a significant improvement of structural parameters—Surface Architecture (P = 0.007) and Surface/Superficial Assessment (P = 0.042)—as well as cellular parameters—Cell Viability (P = 0.006) and Cell Distribution (P = 0.032). No histological parameters were significantly better for the microfracture group. BST-CarGel treatment also resulted in a more organized repair tissue with collagen stratification more similar to native hyaline cartilage, as measured by polarized light microscopy scoring (P = 0.0003). Conclusion Multiple and independent analyses in this biopsy substudy demonstrated that BST-CarGel treatment results in improved structural and cellular characteristics of repair tissue at 1 year posttreatment compared with

  15. Optical determination of the hemoglobin oxygenation state of breast biopsies and human breast cancer xenografts in nude mice

    Science.gov (United States)

    Marks, Fay A.

    1992-05-01

    Differences in the oxygenation state of benign and malignant breast biopsies, and human breast cancer xenografts in immune-deficient mice were monitored using a spectrophotometer with integrating sphere. The breast biopsies were maintained below -50 degree(s)C and the mouse model tumors maintained in growth medium at 0 degree(s)C. Tissue sections 500 (mu) thick were allowed to come up to room temperature for mounting between quartz slides and were evaluated over the wavelength region 240 - 2500 nm. Data collection was done within 10 minutes of the removal of the biopsies from storage and, within 5 minutes for the xenografts. That this preparation protocol allowed us to study the samples very close to the in- vivo state was evident from the lack of deoxyhemoglobin in the benign samples. Component analysis performed in the 300 - 800 nm region showed that the malignant samples contained predominantly deoxygenated blood while the benign samples exhibited oxyhemoglobin signature. Absorption peaks due to fat and traces of bilirubin were also resolved in some of the samples. Assuming that the samples are very nearly representative of the in-vivo condition, these hemoglobin differences may well serve as a basis for imaging tumors or, for tissue characterization in a minimally invasive environment.

  16. Liquid biopsies in gastrointestinal malignancies: when is the big day?

    Science.gov (United States)

    Lopez, Anthony; Harada, Kazuto; Mizrak Kaya, Dilsa; Dong, Xiaochuan; Song, Shumei; Ajani, Jaffer A

    2018-01-01

    Tumor tissue sample is currently the gold standard for diagnosing gastrointestinal cancers, but also for genomic/immune component analyses that can help in the selection of therapy. However, this approach of studying a 'representative' sample of the tumor does not address inherent heterogeneity. Liquid biopsies, mainly represented by circulating tumor cells, circulating tumor DNA, tumor exosomes, and microRNAs, have the potential to assess various biomarkers for early detection of cancer, carrying out genomic/immune profiling for not only selection of appropriate therapy but also to monitor effect of therapy. Areas covered: This review summarizes the current evidence in the literature on liquid biopsies in gastrointestinal cancers concerning diagnosis, prognosis, and response to therapy. The following terms were used in PubMed: 'esophageal', 'gastric', 'colorectal', 'cancer', 'circulating tumor cells', 'circulating tumor DNA', microRNA', 'diagnosis', 'prognosis', 'response', 'resistance'. Expert commentary: Data increasingly supports the potential of liquid biopsies for early detection, selection of therapy, and monitoring response to therapy. One major question is whether assaying various components of the blood would accommodate considerable context-dependent heterogeneity of gastrointestinal tumors. There are many potential strategies to exploit liquid biopsy use. To put them in to perspective, well-designed and meticulous prospective studies will be needed to prove their usefulness.

  17. Advances in the Management of Upper Gastrointestinal Subepithelial Tumor: Pathologic Diagnosis Using Endoscopy without Endoscopic Ultrasound-Guided Biopsy

    Directory of Open Access Journals (Sweden)

    Hang Lak Lee

    2016-05-01

    Full Text Available Until now, biopsy methods for subepithelial tumors (SETs have focused on endoscopic ultrasound (EUS-guided biopsy; however, these methods have several limitations. We devised a simple method for pathologic diagnosis of SETs. SETs are occasionally diagnosed during endoscopy, and lesions are generally small and asymptomatic. It can be challenging to decide on a management plan for large asymptomatic SETs. EUS imaging provides information regarding the size, layer, and echo pattern of the lesions. Patient management plans have traditionally been determined based on EUS images, whereby the endoscopist chooses to either monitor or remove the tumor. However, EUS alone cannot diagnose and evaluate upper gastrointestinal SETs with high accuracy. As sufficient tissue samples are required for the accurate diagnosis of SETs, EUS-guided biopsy techniques such as EUS fine-needle aspiration and trucut biopsy are currently used. However, these methods have a relatively low diagnostic accuracy and do not always provide information upon immunohistochemical staining. Endoscopists can easily detect a submucosal mass after creating an iatrogenic mucosal ulcer, after which tissue sampling is performed by using endoscopic biopsy. Furthermore, pathologic results can differentiate between benign and premalignant lesions. Here, we introduce a simple method for the pathologic diagnosis of SETs.

  18. Effects of combined liver and udder biopsying on the acute phase response of dairy cows with experimentally induced E. coli mastitis

    DEFF Research Database (Denmark)

    Khatun, Momena; Sørensen, Peter; Ingvartsen, Klaus Lønne

    2013-01-01

    A minimally invasive biopsy technique was evaluated for udder tissue collection in dairy cows with Escherichia coli mastitis. Meanwhile, the effect of taking repeated liver and udder biopsies on the systemic and local acute phase response (APR) of the dairy cows was investigated during the disease...... the systemic and local APR in dairy cows during E. coli mastitis, if the timing of biopsying and other types of sampling is planned accordingly....... The cows were divided into a biopsy group (B) (n = 16) and a no-biopsy group (NB) (n = 16) and were sampled in the acute disease stage and in the recovery stage. The cows’ pre-disease period served as a control period for establishing baseline values for the investigated parameters. A total of 32 Holstein...

  19. Comparative analysis of diagnostic accuracy of different brain biopsy procedures.

    Science.gov (United States)

    Jain, Deepali; Sharma, Mehar Chand; Sarkar, Chitra; Gupta, Deepak; Singh, Manmohan; Mahapatra, A K

    2006-12-01

    Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different stereotactic and ultrasound-guided brain biopsy procedures. A retrospective analysis was conducted of all brain biopsies (frame-based and frameless stereotactic and ultrasound-guided) performed in a single tertiary care neurosciences center between 1995 and 2005. The overall diagnostic accuracy achieved on histopathology and correlation with type of biopsy technique was evaluated. A total of 130 cases were included, which consisted of 82 males and 48 females. Age ranged from 4 to 75 years (mean age 39.5 years). Twenty per cent (27 patients) were in the pediatric age group, while 12% (16 patients) were >or= 60-years of age. A definitive histological diagnosis was established in 109 cases (diagnostic yield 80.2%), which encompassed 101 neoplastic and eight nonneoplastic lesions. Frame-based, frameless stereotactic and ultrasound-guided biopsies were done in 95, 15 and 20 patients respectively. Although the numbers of cases were small there was trend for better yield with frameless image-guided stereotactic biopsy and maximum diagnostic yield was obtained i.e, 87% (13/15) in comparison to conventional frame-based CT-guided stereotactic biopsy and ultrasound-guided biopsy. Overall, a trend of higher diagnostic yield was seen in cases with frameless image-guided stereotactic biopsy. Thus, this small series confirms that frameless neuronavigator-guided stereotactic procedures represent the lesion sufficiently in order to make histopathologic diagnosis.

  20. Comparison of two modalities: a novel technique, 'chromohysteroscopy', and blind endometrial sampling for the evaluation of abnormal uterine bleeding.

    Science.gov (United States)

    Alay, Asli; Usta, Taner A; Ozay, Pinar; Karadugan, Ozgur; Ates, Ugur

    2014-05-01

    The objective of this study was to compare classical blind endometrial tissue sampling with hysteroscopic biopsy sampling following methylene blue dyeing in premenopausal and postmenopausal patients with abnormal uterine bleeding. A prospective case-control study was carried out in the Office Hysteroscopy Unit. Fifty-four patients with complaints of abnormal uterine bleeding were evaluated. Data of 38 patients were included in the statistical analysis. Three groups were compared by examining samples obtained through hysteroscopic biopsy before and after methylene blue dyeing, and classical blind endometrial tissue sampling. First, uterine cavity was evaluated with office hysteroscopy. Methylene blue dye was administered through the hysteroscopic inlet. Tissue samples were obtained from stained and non-stained areas. Blind endometrial sampling was performed in the same patients immediately after the hysteroscopy procedure. The results of hysteroscopic biopsy from methylene blue stained and non-stained areas and blind biopsy were compared. No statistically significant differences were determined in the comparison of biopsy samples obtained from methylene-blue stained, non-stained areas and blind biopsy (P > 0.05). We suggest that chromohysteroscopy is not superior to endometrial sampling in cases of abnormal uterine bleeding. Further studies with greater sample sizes should be performed to assess the validity of routine use of endometrial dyeing. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  1. The value of touch imprint cytology of prostate core needle biopsy ...

    African Journals Online (AJOL)

    S. Hussein

    2015-11-10

    Nov 10, 2015 ... causes of cancer mortality [1]. ... in 5 African-American men will be diagnosed with prostate cancer ... a 20–40% false negative rate of sextant biopsies [6], and it has .... to CNB in breast cancer cases, TIC has been found to improve ... sampling the tissue at three levels only missed an average of 7%.

  2. The clinical relevance of plasma CD147/basigin in biopsy-proven kidney diseases.

    Science.gov (United States)

    Mori, Yoshiko; Masuda, Tomohiro; Kosugi, Tomoki; Yoshioka, Tomoki; Hori, Mayuko; Nagaya, Hiroshi; Maeda, Kayaho; Sato, Yuka; Kojima, Hiroshi; Kato, Noritoshi; Ishimoto, Takuji; Katsuno, Takayuki; Yuzawa, Yukio; Kadomatsu, Kenji; Maruyama, Shoichi

    2017-12-12

    Precise understanding of kidney disease activity is needed to design therapeutic strategies. CD147/basigin is involved in the pathogenesis of acute kidney injury and renal fibrosis through inflammatory cell infiltration. The present study examined the clinical relevance of CD147 in biopsy-proven kidney diseases that lead to the progression of chronic kidney disease. Kidney biopsy specimens and plasma and urine samples were obtained from patients with kidney diseases, including IgA nephropathy (IgAN), Henoch-Schönlein purpura nephritis (HSPN), diabetic kidney disease (DKD), focal segmental glomerulosclerosis (FSGS), and membranous nephropathy (MN), who underwent renal biopsy between 2011 and 2014. Plasma and urinary CD147 levels were measured and evaluated for their ability to reflect histological features. Disease activity of IgAN tissues was evaluated according to the Oxford classification and the Japanese histological grading system. In biopsy tissues, CD147 induction was detected in injured lesions representing renal inflammation. Plasma CD147 values correlated with eGFR in patients with inflammation-related kidney diseases such as IgAN, HSPN, and DKD. Particularly in IgAN patients, plasma CD147 levels were correlated with injured regions comprising more than 50% of glomeruli or with tubular atrophy/interstitial injury in biopsy tissues. Proteinuria showed a closer correlation with urinary values of CD147 and L-FABP. Of note, plasma and urinary CD147 levels showed a strong correlation with eGFR or proteinuria, respectively, only in DKD patients. Evaluation of plasma and urinary CD147 levels might provide key insights for the understanding of the activity of various kidney diseases.

  3. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    Science.gov (United States)

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason  7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  4. Complete removal of a breast mass by US-guided mammotome biopsy: histologic assessment by marginal sampling

    International Nuclear Information System (INIS)

    Kim, Youn Jeong; Choi, Hye Young; Moon, Byung In; Lee, Shi Nae

    2005-01-01

    The aim of this study was to assess whether the complete removal of a breast mass using ultrasound (US) guided mammotome biopsy was successful using a marginal biopsy after insuring the total visual excision of the breast mass on US images. The relationship of complete breast mass removal, and the hematoma, mass size and shape were also evaluated. A US guided mammotome biopsy was performed in a total of 136 cases in 133 patients, with marginal biopsies also added when the complete removal of breast mass had been identified by sonography. The results of the marginal biopsies were serially dividing into three groups, as follows: group I were the cases in the initial 6 months, group II after the initial 6 months and group III having undergone two marginal biopsies. The marginal biopsies were performed in four directions around the probe, with 'marginal positivity' defined as the same histopathological findings to that of the main mass in at least one direction. A statistical analysis was also used to evaluate between the marginal positivity and the hematoma, mass size and shape. The marginal positivities of groups I, II and III were 48.8, 29.4 and 45.5%, respectively. The marginal positivity of those with a lobular shaped mass was significantly higher (ρ = 0.0121) than those with round or oval shaped masses (61.5 vs 33.7 vs 50%), but showed no statistical relationship with hematoma size of the lesions. Although the lesions were removed by US using a US-guided mammotome biopsy, many residual lesions were still histologically present in the marginal samplings, especially in the lobular shaped masse

  5. Incidence of delayed complications following percutaneous CT-guided biopsy of bone and soft tissue lesions of the spine and extremities: A 2-year prospective study and analysis of risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Rosenthal, Daniel I. [Massachusetts General Hospital, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute of Technology Assessment, Boston, MA (United States)

    2013-01-15

    To prospectively evaluate the incidence of delayed complications (bleeding, pain, infection) following CT-guided biopsies of bone or soft tissue lesions and to identify risk factors that predispose to their occurrence. All adults presenting for CT-guided biopsy of a bone or soft tissue lesion were eligible for the study. Risk factors considered included patient gender and age, bone versus soft tissue, lesion location, lesion depth, anticoagulation, conscious sedation, coaxial biopsy technique, bleeding during the biopsy, dressing type and duration of placement, final diagnosis, needle gauge, number of passes, and number of days to follow-up. Outcomes measured included fever, pain, bruising/hematoma formation, and swelling and were collected by a follow-up phone call within 14 days of the biopsy. Fisher's exact test, the Wald Chi-square test, and univariate, multivariate, and stepwise logistic regression were performed to evaluate the influence of the risk factors on the outcomes. A total of 386 patients participated in the study. The rates of post-biopsy fever, pain, bruising, and swelling were 1.0, 16.1, 15.6, and 9.6 %, respectively. Anticoagulants were identified as a risk factor for fever. Increasing patient age was identified as a risk factor for pain. Female gender and lesion location were identified as risk factors for bruising. Increasing patient age and lesion location were identified as risk factors for swelling. Patient age, female gender, and lesion location are risk factors for delayed minor complications following CT-guided biopsy of a bone or soft tissue lesion. There were no major complications. None of the complications in this series altered patient management. (orig.)

  6. Incidence of delayed complications following percutaneous CT-guided biopsy of bone and soft tissue lesions of the spine and extremities: A 2-year prospective study and analysis of risk factors

    International Nuclear Information System (INIS)

    Huang, Ambrose J.; Rosenthal, Daniel I.; Halpern, Elkan F.

    2013-01-01

    To prospectively evaluate the incidence of delayed complications (bleeding, pain, infection) following CT-guided biopsies of bone or soft tissue lesions and to identify risk factors that predispose to their occurrence. All adults presenting for CT-guided biopsy of a bone or soft tissue lesion were eligible for the study. Risk factors considered included patient gender and age, bone versus soft tissue, lesion location, lesion depth, anticoagulation, conscious sedation, coaxial biopsy technique, bleeding during the biopsy, dressing type and duration of placement, final diagnosis, needle gauge, number of passes, and number of days to follow-up. Outcomes measured included fever, pain, bruising/hematoma formation, and swelling and were collected by a follow-up phone call within 14 days of the biopsy. Fisher's exact test, the Wald Chi-square test, and univariate, multivariate, and stepwise logistic regression were performed to evaluate the influence of the risk factors on the outcomes. A total of 386 patients participated in the study. The rates of post-biopsy fever, pain, bruising, and swelling were 1.0, 16.1, 15.6, and 9.6 %, respectively. Anticoagulants were identified as a risk factor for fever. Increasing patient age was identified as a risk factor for pain. Female gender and lesion location were identified as risk factors for bruising. Increasing patient age and lesion location were identified as risk factors for swelling. Patient age, female gender, and lesion location are risk factors for delayed minor complications following CT-guided biopsy of a bone or soft tissue lesion. There were no major complications. None of the complications in this series altered patient management. (orig.)

  7. Optical biopsy of head and neck cancer using hyperspectral imaging and convolutional neural networks

    Science.gov (United States)

    Halicek, Martin; Little, James V.; Wang, Xu; Patel, Mihir; Griffith, Christopher C.; El-Deiry, Mark W.; Chen, Amy Y.; Fei, Baowei

    2018-02-01

    Successful outcomes of surgical cancer resection necessitate negative, cancer-free surgical margins. Currently, tissue samples are sent to pathology for diagnostic confirmation. Hyperspectral imaging (HSI) is an emerging, non-contact optical imaging technique. A reliable optical method could serve to diagnose and biopsy specimens in real-time. Using convolutional neural networks (CNNs) as a tissue classifier, we developed a method to use HSI to perform an optical biopsy of ex-vivo surgical specimens, collected from 21 patients undergoing surgical cancer resection. Training and testing on samples from different patients, the CNN can distinguish squamous cell carcinoma (SCCa) from normal aerodigestive tract tissues with an area under the curve (AUC) of 0.82, 81% accuracy, 81% sensitivity, and 80% specificity. Additionally, normal oral tissues can be sub-classified into epithelium, muscle, and glandular mucosa using a decision tree method, with an average AUC of 0.94, 90% accuracy, 93% sensitivity, and 89% specificity. After separately training on thyroid tissue, the CNN differentiates between thyroid carcinoma and normal thyroid with an AUC of 0.95, 92% accuracy, 92% sensitivity, and 92% specificity. Moreover, the CNN can discriminate medullary thyroid carcinoma from benign multi-nodular goiter (MNG) with an AUC of 0.93, 87% accuracy, 88% sensitivity, and 85% specificity. Classical-type papillary thyroid carcinoma is differentiated from benign MNG with an AUC of 0.91, 86% accuracy, 86% sensitivity, and 86% specificity. Our preliminary results demonstrate that an HSI-based optical biopsy method using CNNs can provide multi-category diagnostic information for normal head-and-neck tissue, SCCa, and thyroid carcinomas. More patient data are needed in order to fully investigate the proposed technique to establish reliability and generalizability of the work.

  8. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  9. Axillary lymph node core biopsy for breast cancer metastases — How many needle passes are enough?

    International Nuclear Information System (INIS)

    Macaskill, E.J.; Purdie, C.A.; Jordan, L.B.; Mclean, D.; Whelehan, P.; Brown, D.C.; Evans, A.

    2012-01-01

    Aim: To determine the diagnostic yield of each of three core passes when sampling abnormal lymph nodes in patients presenting with breast cancer. Materials and methods: All patients suspected of having breast cancer had axillary ultrasound as part of initial assessment. Radiologically abnormal nodes (cortical thickness >2.3 mm or round shape) were biopsied with three passes of a 22 mm throw 14 G core biopsy needle and sent for histopathology in separate numbered pots. Data were collected prospectively, and analysis performed on the data of 55 consecutive patients who had positive nodes on at least one core biopsy needle pass. Results: Of 55 patients with a positive node on core biopsy, tumour was noted in all three cores taken in 39 (70.9%). Lymph node metastasis was detected in 45 (81.8%) first core biopsies. With the first two cores taken, positive results were detected in 53 of 55 cases (96.4%). In both cases where tumour was only found on a third core biopsy pass, no lymph node tissue was present in the first two biopsy passes. Conclusion: Two well-directed 14 G core biopsy samples from an abnormal axillary node are adequate for diagnosis of breast cancer metastasis.

  10. PRELIMINARY EVALUATION OF SPIROTOME® DEVICE FOR LIVER BIOPSY IN GREEN IGUANAS (IGUANA IGUANA): A PILOT STUDY.

    Science.gov (United States)

    Nardini, Giordano; Origgi, Francesco C; Leopardi, Stefania; Zaghini, Anna; Saunders, Jimmy H; Vignoli, Massimo

    2016-06-01

    The aim of this study was to evaluate a large-core manual biopsy device (Spirotome(®), Medinvents, 3500 Hasselt, Belgium) for liver sampling and histologic diagnosis in green iguanas (Iguana iguana). The study included eight green iguanas, and two ultrasound-guided biopsies were collected for each lizard, for 16 biopsies in total. The procedure was carried out under general anesthesia induced by intravenous injection of propofol (10 mg/kg) maintained with a mixture of 2.0% isoflurane and 0.8-1.2 L/min oxygen after tracheal intubation. Fourteen (87.5%) of the 16 biopsies were considered diagnostic. Liver biopsy quality was assessed according to sample size and tissue preservation. In particular, mean length (16.2 ± 4.5 mm), width (2.2 ± 0.5 mm), area (34.8 ± 6.9 mm(2)), and number of portal areas (9.4 ± 3.9) of each biopsy were recorded for all green iguanas. The total available surface of the sections obtained from the biopsies and their grade of preservation enabled a satisfactory evaluation of the parenchymal architecture. One of the green iguanas in the study died the day after the procedure due to severe hemocoeloma. Risk assessment evaluation suggested that small green iguanas may not be suitable for this biopsy procedure.

  11. [When to ask for a skin biopsy in a patient with leg ulcer? Retrospective study of 143 consecutive biopsies].

    Science.gov (United States)

    Stansal, A; Khayat, K; Duchatelle, V; Tella, E; Gautier, V; Sfeir, D; Attal, R; Lazareth, I; Priollet, P

    2018-02-01

    A vascular cause is found in around 85% of leg ulcer patients, but non-vascular causes are also observed. Their diagnosis is based on a set of clinical arguments and skin biopsy with histological analysis. The aim of this study was to analyze the results of these biopsies and to find common criteria for ulcers whose skin biopsies had led to the diagnosis of a non-vascular ulcer. A retrospective study was carried out on the analysis of 143 skin biopsies of leg ulcers. The reasons for the biopsy were mainly atypical clinical signs and/or the lack of improvement in care after 6 months, as advocated by the French health authorities. The skin biopsies led to a diagnosis of non-vascular ulcer in 4.9% of cases (7/143), including skin cancer (n=5, 3.5%), cutaneous leishmaniasis (n=1, 0.7%) and Pyoderma gangrenosum (n=1, 0.7%). The univariate statistical analysis revealed that an elevated rim and abnormal excessive granulation tissue were significantly more frequently found in these ulcers. All patients with a positive skin biopsy had associated vascular involvement. This study found a 5% rate of non-vascular causes of ulcers, mainly skin cancer. Elevated rims and abnormal excessive granulation tissue were the unusual features most commonly found in these ulcers. All patients whose skin biopsy revealed a non-vascular cause had associated vascular involvement. This information confirms the need to perform a skin biopsy, even in the presence of a vascular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    Science.gov (United States)

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  13. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    Science.gov (United States)

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  14. Balloon dilatation biopsy of the biliary stricture through the percutaneous transhepatic biliary drainage tract: Feasibility and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Ji Hoon; Ryeom, Hun Kyu; Jang, Yun Jin; Kim, Gab Chul; Cho, Seung Hyun; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2016-01-15

    To evaluate the feasibility and diagnostic accuracy of the balloon dilatation biopsy for the biliary stricture through the percutaneous transhepatic biliary drainage (PTBD) tract. The study included 35 patients who underwent balloon dilatation biopsy for the biliary stricture through the PTBD tract. Balloon dilatation was done with a balloon catheter of 10-mm or 12-mm diameter. Soft tissue adherent to the retrieved balloon catheter and soft tissue components separated by gauze filtration of evacuated bile were sampled for histopathologic examination. The results were compared with the final diagnosis which was made by clinical and imaging follow-up for mean 989 days (n = 34) and surgery with histopathologic examination (n = 1). Procedure-related complications and diagnostic accuracy were assessed. Tissues suitable for histopathologic examination were obtained in 31 out of 35 patients (88.6%). In 3 patients, self-limiting hemobilia was noted. No major complication was noted. The sensitivity, specificity, diagnostic accuracy, positive and negative predictive values for diagnosis of malignant stricture were 70.0%, 100%, 90.3%, 100%, and 87.5%, respectively. Balloon dilatation biopsy of the biliary stricture through the PTBD tract is a feasible and accurate diagnostic method. It can be a safe alternative to the endoscopic retrograde cholangiography biopsy or forceps biopsy through the PTBD tract.

  15. Magnetic resonance metabolic profiling of breast cancer tissue obtained with core needle biopsy for predicting pathologic response to neoadjuvant chemotherapy.

    Directory of Open Access Journals (Sweden)

    Ji Soo Choi

    Full Text Available The purpose of this study was to determine whether metabolic profiling of core needle biopsy (CNB samples using high-resolution magic angle spinning (HR-MAS magnetic resonance spectroscopy (MRS could be used for predicting pathologic response to neoadjuvant chemotherapy (NAC in patients with locally advanced breast cancer. After institutional review board approval and informed consent were obtained, CNB tissue samples were collected from 37 malignant lesions in 37 patients before NAC treatment. The metabolic profiling of CNB samples were performed by HR-MAS MRS. Metabolic profiles were compared according to pathologic response to NAC using the Mann-Whitney test. Multivariate analysis was performed with orthogonal projections to latent structure-discriminant analysis (OPLS-DA. Various metabolites including choline-containing compounds were identified and quantified by HR-MAS MRS in all 37 breast cancer tissue samples obtained by CNB. In univariate analysis, the metabolite concentrations and metabolic ratios of CNB samples obtained with HR-MAS MRS were not significantly different between different pathologic response groups. However, there was a trend of lower levels of phosphocholine/creatine ratio and choline-containing metabolite concentrations in the pathologic complete response group compared to the non-pathologic complete response group. In multivariate analysis, the OPLS-DA models built with HR-MAS MR metabolic profiles showed visible discrimination between the pathologic response groups. This study showed OPLS-DA multivariate analysis using metabolic profiles of pretreatment CNB samples assessed by HR- MAS MRS may be used to predict pathologic response before NAC, although we did not identify the metabolite showing statistical significance in univariate analysis. Therefore, our preliminary results raise the necessity of further study on HR-MAS MR metabolic profiling of CNB samples for a large number of cancers.

  16. Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time

    International Nuclear Information System (INIS)

    Hoffmann, Ruediger; Thomas, Christoph; Rempp, Hansjoerg; Schmidt, Diethard; Claussen, Claus D.; Clasen, Stephan; Pereira, Philippe L.

    2012-01-01

    To assess the accuracy, the duration and factors that influence the duration of MRI-guided liver or soft-tissue biopsies. Nineteen liver biopsies and 19 soft-tissue biopsies performed using 1.5T-MRI guidance were retrospectively analysed. Diagnostic performance and complications were assessed. Intervention time was subdivided into preparation period, puncture period and control period. Correlation between procedure time and target size, skin-to-target-distance, used sequences and interventionalists' experience were analysed. Overall sensitivity, specificity and accuracy were 0.86, 1.0 and 0.92, respectively. Two minor complications occurred. Overall median procedure time was 103.5 min. Liver biopsies lasted longer than soft-tissue biopsies (mean [soft-tissue] : 73.0 min, mean [liver] : 134.1 min, P [liver] = 0.048, P [soft-tissue] = 0.005) was significantly prolonged for longer skin-to-target-distances. Lower numbers of image acquisitions (P [liver] = 0.0007, P [soft-tissue] = 0.0012) and interventionalists' experience reduces the procedure duration significantly (P < 0.05), besides all false-negative results appeared during the first five biopsies of each individual radiologist. The interventionalists' experience, skin-to-target-distances and number of image acquisition influence the procedure time significantly. (orig.)

  17. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  18. Quantitative analysis of fine needle aspiration biopsy samples

    International Nuclear Information System (INIS)

    Rajer, M.; Kmet, M.

    2005-01-01

    Background. The fine needle aspiration biopsy (FNAB) is one of the methods used in tumour evaluation. Since a certain number of tumour cells are needed for a complete diagnostic algorithm, we wanted to test how many cells remain in the needle and syringe after routine stains have been made and which factors influence this number. The remaining cells are used in ancillary diagnostic procedures. Materials and methods. One hundred fifty two FNAB samples of tumours of the breast, thyroid and lymph nodes were included in our study. We counted the cells which were left in the needle and the syringe after the standard smears had been made. Buerker-Tuerk's chamber was used for this purpose. Results. The number of cells depended on the organ from which the cells had been aspirated, on the type of tumour and, in the case of breast cancer, also on the level of experience of the FNAB performer. The percentage of samples with too few cells for all modern diagnostic methods (<5x105 ) is lowest in FNAB of lymph nodes (4.9%), followed by breast (16.7%) and thyroid (18%). Conclusions. We concluded that FNAB in the majority of cases grants a sufficient number of cells for the standard microscopic evaluation and also ancillary diagnostic procedures. (author)

  19. Lack of detection of human papillomavirus infection by hybridization test in prostatic biopsies

    International Nuclear Information System (INIS)

    Gazzaz, Faten S; Mosli, Hisham A

    2009-01-01

    To explore the possibility of finding human papillomavirus (HPV) infection in the prostate tissue of a cohort of Saudi men presenting with benign prostatic hyperplasia (BPH) or prostate cancer. A cohort study on prospectively collected tissue samples was conducted at King Abdulaziz University Hospital (KAUH), Jeddah, Kingdom of Saudi Arabia from March 2007 to December 2008 on a total of 56 male patients, age range 50-93 years (average 68), diagnosed as having BPH or prostate cancer. The HPV DNA hybridization by hybrid capture 2 technology was performed on prostate biopsies of these patients to detect 18 types of HPV infection, and differentiate between 2 HPV DNA groups, the low-risk types, and the high/intermediate risk types.The tissues of all the prostatic biopsies were negative for HPV DNA. Our results, using the hybridization test, indicate that it is unlikely that HPV-16 or HPV-18, or the other tested subtypes, enhance the risk of prostate cancer. (author)

  20. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  1. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  2. Operator dependent choice of prostate cancer biopsy has limited impact on a gene signature analysis for the highly expressed genes IGFBP3 and F3 in prostate cancer epithelial cells.

    Directory of Open Access Journals (Sweden)

    Zhuochun Peng

    Full Text Available BACKGROUND: Predicting the prognosis of prostate cancer disease through gene expression analysis is receiving increasing interest. In many cases, such analyses are based on formalin-fixed, paraffin embedded (FFPE core needle biopsy material on which Gleason grading for diagnosis has been conducted. Since each patient typically has multiple biopsy samples, and since Gleason grading is an operator dependent procedure known to be difficult, the impact of the operator's choice of biopsy was evaluated. METHODS: Multiple biopsy samples from 43 patients were evaluated using a previously reported gene signature of IGFBP3, F3 and VGLL3 with potential prognostic value in estimating overall survival at diagnosis of prostate cancer. A four multiplex one-step qRT-PCR test kit, designed and optimized for measuring the signature in FFPE core needle biopsy samples was used. Concordance of gene expression levels between primary and secondary Gleason tumor patterns, as well as benign tissue specimens, was analyzed. RESULTS: The gene expression levels of IGFBP3 and F3 in prostate cancer epithelial cell-containing tissue representing the primary and secondary Gleason patterns were high and consistent, while the low expressed VGLL3 showed more variation in its expression levels. CONCLUSION: The assessment of IGFBP3 and F3 gene expression levels in prostate cancer tissue is independent of Gleason patterns, meaning that the impact of operator's choice of biopsy is low.

  3. Tissue Sampling Guides for Porcine Biomedical Models.

    Science.gov (United States)

    Albl, Barbara; Haesner, Serena; Braun-Reichhart, Christina; Streckel, Elisabeth; Renner, Simone; Seeliger, Frank; Wolf, Eckhard; Wanke, Rüdiger; Blutke, Andreas

    2016-04-01

    This article provides guidelines for organ and tissue sampling adapted to porcine animal models in translational medical research. Detailed protocols for the determination of sampling locations and numbers as well as recommendations on the orientation, size, and trimming direction of samples from ∼50 different porcine organs and tissues are provided in the Supplementary Material. The proposed sampling protocols include the generation of samples suitable for subsequent qualitative and quantitative analyses, including cryohistology, paraffin, and plastic histology; immunohistochemistry;in situhybridization; electron microscopy; and quantitative stereology as well as molecular analyses of DNA, RNA, proteins, metabolites, and electrolytes. With regard to the planned extent of sampling efforts, time, and personnel expenses, and dependent upon the scheduled analyses, different protocols are provided. These protocols are adjusted for (I) routine screenings, as used in general toxicity studies or in analyses of gene expression patterns or histopathological organ alterations, (II) advanced analyses of single organs/tissues, and (III) large-scale sampling procedures to be applied in biobank projects. Providing a robust reference for studies of porcine models, the described protocols will ensure the efficiency of sampling, the systematic recovery of high-quality samples representing the entire organ or tissue as well as the intra-/interstudy comparability and reproducibility of results. © The Author(s) 2016.

  4. Detection of cancer in cervical tissue biopsies using mobile lipid resonances measured with diffusion-weighted (1)H magnetic resonance spectroscopy.

    Science.gov (United States)

    Zietkowski, D; Davidson, R L; Eykyn, T R; De Silva, S S; Desouza, N M; Payne, G S

    2010-05-01

    The purpose of this study was to implement a diffusion-weighted sequence for visualisation of mobile lipid resonances (MLR) using high resolution magic angle spinning (HR-MAS) (1)H MRS and to evaluate its use in establishing differences between tissues from patients with cervical carcinoma that contain cancer from those that do not. A stimulated echo sequence with bipolar gradients was modified to allow T(1) and T(2) measurements and optimised by recording signal loss in HR-MAS spectra as a function of gradient strength in model lipids and tissues. Diffusion coefficients, T(1) and apparent T(2) relaxation times were measured in model lipid systems. MLR profiles were characterised in relation to T(1) and apparent T(2) relaxation in human cervical cancer tissue samples. Diffusion-weighted (DW) spectra of cervical biopsies were quantified and peak areas analysed using linear discriminant analysis (LDA). The optimised sequence reduced spectral overlap by suppressing signals originating from low molecular weight metabolites and non-lipid contributions. Significantly improved MLR visualisation allowed visualisation of peaks at 0.9, 1.3, 1.6, 2.0, 2.3, 2.8, 4.3 and 5.3 ppm. MLR analysis of DW spectra showed at least six peaks arising from saturated and unsaturated lipids and those arising from triglycerides. Significant differences in samples containing histologically confirmed cancer were seen for peaks at 0.9 (p Operating Characteristic (ROC) curves and calculated area under the curve (0.962) validated high sensitivity and specificity of the technique. Diffusion-weighting of HR-MAS spectroscopic sequences is a useful method for characterising MLR in cancer tissues and displays an accumulation of lipids arising during tumourigenesis and an increase in the unsaturated lipid and triglyceride peaks with respect to saturated MLR. Copyright © 2009 John Wiley & Sons, Ltd.

  5. Sono-Guided Percutaneous Automated Gun Biopsy in Pediatric Renal Disease

    International Nuclear Information System (INIS)

    Kim, Jong Chul

    1996-01-01

    To evaluate whether sono-guided percutaneous automated gun biopsy is also useful in pediatricpatients with renal diseases. In the prone position of twenty pediatric patients with renal parenchymal diseases, percutaneous biopsy was done through lateral aspect of the lower pole of left kidney with automated biopsy gun under the guidance of ultrasonography. The biopsy needle was either of 18 or 20 gauge. The obtained core of renal tissue was examined with light, immunofluorescent or electron microscope by the renal pathologist. In 18 among 20 patients, adequate renal tissue core sufficient to be pathologically diagnosed was obtained. The histologic findings were as follows : IG A nephropathy (n = 2), lupus nephritis (n =2), minimal change glomerulonephritis (n = 5), membranoproliferative glomerulonephritis (n = 3), mesangialproliferative glomeru-lonephritis (n = 1), diffuse proliferative glomerulonephritis (n = 3), focalglomerulo-sclerosis (n = 1), membranous glomerulopathy (n = 1). No significant complications occurred during or after the biopsy. Sono-guided percutaneous renal biopsy using automated biopsy gun is also useful todiagnose renal parenchymal diseases without significant complications in pediatric patients

  6. A Novel Design of Needle Aspiration Biopsy Monitoring Instrument (NAOMI Tested on a Low Cost Chest Phantom

    Directory of Open Access Journals (Sweden)

    Surakusumah Rino Ferdian

    2016-01-01

    Full Text Available Needle biopsy is a medical intervention method for taking a lung tissue sample that suspected as a cancer. The disadvantage is the physicians directly visualize the anatomical structures in an open surgery for lung cancer biopsy procedure. There is a need to develop an instrument that may help the physician to guarantee the accuracy and efficiency while performing needle aspiration biopsy. Therefore, a needle aspiration biopsy monitoring instrument or named as NAOMI is proposed. It consists of a microcontroller system, an IMU sensor, an ultrasonic ranging module, a bluetooth module, and a 9V lithium battery. The experimental testing consist of performance testing, functional testing using chest phantom, and user acceptances. The results showed that the NAOMI improve the accuracy and efficiency while performing the needle biopsy operation.

  7. Determination of trace elements in human liver biopsy samples by ICP-MS and TXRF: hepatic steatosis and nickel accumulation

    Energy Technology Data Exchange (ETDEWEB)

    Varga, Imre; Szoboszlai, Norbert [L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, Budapest (Hungary); Szebeni, Agnes [MI Central Hospital, Ultrasound Laboratory, Budapest (Hungary); Kovacs, Bela [Debrecen University - Centre of Agricultural Sciences, Department of Food Science and Quality Assurance, P.O. Box 36, Debrecen (Hungary)

    2005-10-01

    Human liver biopsy samples, collected from 52 individuals, were analysed by inductively coupled plasma-mass spectrometry (ICP-MS) and total reflection X-ray fluorescence (TXRF) spectrometry in a retrospective study (i.e. patient selection and liver biopsy were not for the purpose of element analysis). The freeze-dried samples (typically 0.5-2 mg dry weight) were digested in a laboratory microwave digestion system and solutions with a final volume of 1 mL were prepared. The concentrations of Cr, Mn, Fe, Ni, Cu, Zn, Rb, and Pb were determined by use of a Thermo Elemental X7 ICP-MS spectrometer. TXRF measurements were performed with an Atomika Extra IIA spectrometer. Yttrium was employed as an internal standard, prepared by dissolution of 5N-purity yttria (Y{sub 2}O{sub 3}) in our laboratory. The accuracy was tested by analysis of NIST 1577a Bovine Liver certified reference material. The concentrations of Fe, Cu, Zn, and Rb determined in human liver biopsy samples were in good agreement with data published by other authors. The distribution of nickel in the samples was surprisingly uneven - nickel concentrations ranged from 0.7 to 12 {mu}g g{sup -1} (dry weight) in 38 samples and in several samples were extremely high, 36-693 {mu}g g{sup -1}. Analysis of replicate procedural blanks and control measurements were performed to prevent misinterpretation of the data. For patients with steatosis (n=14) Ni concentrations were consistently high except for two who had levels close to those measured for the normal group. As far as we are aware no previous literature data are available on the association of steatosis with high concentration of nickel in human liver biopsies taken from living patients. (orig.)

  8. Diagnostic Algorithm to Reflect Regressive Changes of Human Papilloma Virus in Tissue Biopsies

    Science.gov (United States)

    Lhee, Min Jin; Cha, Youn Jin; Bae, Jong Man; Kim, Young Tae

    2014-01-01

    Purpose Landmark indicators have not yet to be developed to detect the regression of cervical intraepithelial neoplasia (CIN). We propose that quantitative viral load and indicative histological criteria can be used to differentiate between atypical squamous cells of undetermined significance (ASCUS) and a CIN of grade 1. Materials and Methods We collected 115 tissue biopsies from women who tested positive for the human papilloma virus (HPV). Nine morphological parameters including nuclear size, perinuclear halo, hyperchromasia, typical koilocyte (TK), abortive koilocyte (AK), bi-/multi-nucleation, keratohyaline granules, inflammation, and dyskeratosis were examined for each case. Correlation analyses, cumulative logistic regression, and binary logistic regression were used to determine optimal cut-off values of HPV copy numbers. The parameters TK, perinuclear halo, multi-nucleation, and nuclear size were significantly correlated quantitatively to HPV copy number. Results An HPV loading number of 58.9 and AK number of 20 were optimal to discriminate between negative and subtle findings in biopsies. An HPV loading number of 271.49 and AK of 20 were optimal for discriminating between equivocal changes and obvious koilocytosis. Conclusion We propose that a squamous epithelial lesion with AK of >20 and quantitative HPV copy number between 58.9-271.49 represents a new spectrum of subtle pathological findings, characterized by AK in ASCUS. This can be described as a distinct entity and called "regressing koilocytosis". PMID:24532500

  9. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  10. Sampling Strategies and Processing of Biobank Tissue Samples from Porcine Biomedical Models.

    Science.gov (United States)

    Blutke, Andreas; Wanke, Rüdiger

    2018-03-06

    In translational medical research, porcine models have steadily become more popular. Considering the high value of individual animals, particularly of genetically modified pig models, and the often-limited number of available animals of these models, establishment of (biobank) collections of adequately processed tissue samples suited for a broad spectrum of subsequent analyses methods, including analyses not specified at the time point of sampling, represent meaningful approaches to take full advantage of the translational value of the model. With respect to the peculiarities of porcine anatomy, comprehensive guidelines have recently been established for standardized generation of representative, high-quality samples from different porcine organs and tissues. These guidelines are essential prerequisites for the reproducibility of results and their comparability between different studies and investigators. The recording of basic data, such as organ weights and volumes, the determination of the sampling locations and of the numbers of tissue samples to be generated, as well as their orientation, size, processing and trimming directions, are relevant factors determining the generalizability and usability of the specimen for molecular, qualitative, and quantitative morphological analyses. Here, an illustrative, practical, step-by-step demonstration of the most important techniques for generation of representative, multi-purpose biobank specimen from porcine tissues is presented. The methods described here include determination of organ/tissue volumes and densities, the application of a volume-weighted systematic random sampling procedure for parenchymal organs by point-counting, determination of the extent of tissue shrinkage related to histological embedding of samples, and generation of randomly oriented samples for quantitative stereological analyses, such as isotropic uniform random (IUR) sections generated by the "Orientator" and "Isector" methods, and vertical

  11. Current Strategies for Quantitating Fibrosis in Liver Biopsy

    Directory of Open Access Journals (Sweden)

    Yan Wang

    2015-01-01

    Full Text Available Objective: The present mini-review updated the progress in methodologies based on using liver biopsy. Data Sources: Articles for study of liver fibrosis, liver biopsy or fibrosis assessment published on high impact peer review journals from 1980 to 2014. Study Selection: Key articles were selected mainly according to their levels of relevance to this topic and citations. Results: With the recently mounting progress in chronic liver disease therapeutics, comes by a pressing need for precise, accurate, and dynamic assessment of hepatic fibrosis and cirrhosis in individual patients. Histopathological information is recognized as the most valuable data for fibrosis assessment. Conventional histology categorical systems describe the changes of fibrosis patterns in liver tissue; but the simplified ordinal digits assigned by these systems cannot reflect the fibrosis dynamics with sufficient precision and reproducibility. Morphometric assessment by computer assist digital image analysis, such as collagen proportionate area (CPA, detects change of fibrosis amount in tissue section in a continuous variable, and has shown its independent diagnostic value for assessment of advanced or late-stage of fibrosis. Due to its evident sensitivity to sampling variances, morphometric measurement is feasible to be taken as a reliable statistical parameter for the study of a large cohort. Combining state-of-art imaging technology and fundamental principle in Tissue Engineering, structure-based quantitation was recently initiated with a novel proof-of-concept tool, qFibrosis. qFibrosis showed not only the superior performance to CPA in accurately and reproducibly differentiating adjacent stages of fibrosis, but also the possibility for facilitating analysis of fibrotic regression and cirrhosis sub-staging. Conclusions: With input from multidisciplinary innovation, liver biopsy assessment as a new "gold standard" is anticipated to substantially support the accelerated

  12. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  13. Unmasking of complements using proteinase-K in formalin fixed paraffin embedded renal biopsies

    Directory of Open Access Journals (Sweden)

    R Nada

    2016-01-01

    Full Text Available Renal biopsy interpretation requires histopathology, direct immunofluorescence (DIF and electron microscopy. Formalin-fixed, paraffin-embedded tissue (FFPE sent for light microscopy can be used for DIF after antigen retrieval. However, complement staining has not been satisfactory. We standardized DIF using proteinase-K for antigen retrieval in FFPE renal biopsies. A pilot study was conducted on known cases of membranous glomerulonephritis (MGN, membranoproliferative type-1 (MPGN-1, immunoglobulin A nephropathy (IgAN, and anti-glomerular basement disease (anti-GBM. Immunofluorescence panel included fluorescein isothiocyanate (FITC conjugated IgG, IgA, IgM, complements (C3 and C1q, light chains (kappa, lambda and fibrinogen antibodies. After standardization of the technique, 75 renal biopsies and 43 autopsies cases were stained. Out of 43 autopsy cases, immune-complex mediated glomerulonephritis (GN was confirmed in 18 cases (Lupus nephritis-11, IgAN-6, MGN-1, complement-mediated dense deposit disease (DDD-1 and monoclonal diseases in 4 cases (amyloidosis-3, cast nephropathy-1. Immune-mediated injury was excluded in 17 cases (focal segmental glomerulosclerosis -3, crescentic GN-6 [pauci-immune-3, anti-GBM-3], thrombotic microangiopathy-5, atherosclerosis-3. Renal biopsies (n-75 where inadequate or no frozen sample was available; this technique classified 52 mesangiocapillary pattern as MPGN type-1-46, DDD-2 and (C3GN-4. Others were diagnosed as IgAN-3, lupus nephritis-2, MGN-4, diffuse proliferative glomerulonephritis (DPGN-1, Non-IC crescentic GN-1, monoclonal diseases-3. In nine cases, DIF on FFPE tissue could not help in making diagnosis. Proteinase-K enzymatic digestion of FFPE renal biopsies can unmask complements (both C3 and C1q in immune-complexes mediated and complement-mediated diseases. This method showed good results on autopsy tissues archived for as long as 15 years.

  14. Indications and results of renal biopsy in children: a 36-year experience.

    Science.gov (United States)

    Santangelo, Luisa; Netti, Giuseppe Stefano; Giordano, Paolo; Carbone, Vincenza; Martino, Marida; Torres, Diletta Domenica; Rossini, Michele; Di Palma, Anna Maria; Gesualdo, Loreto; Giordano, Mario

    2018-04-01

    This study was conducted to investigate retrospectively the indications for renal biopsy (RB) in native kidneys and to analyze pathological findings in a single tertiary pediatric hospital in Southern Italy for the last 36 years. All patients who underwent RB at our hospital from 1979 to 2014 were included. All renal tissue specimens were studied under light and immunofluorescent microscopy, while electron microscopy was performed only for specific clinical indications. The study group included 213 patients (female 43.2%) who underwent 225 percutaneous native kidney biopsies. Median age was 10.4 years (range 0.6-24 years). The most frequent indication for RB was nephrotic syndrome (44.4%), followed by proteinuria (27.6%), asymptomatic hematuria (17.3%) and acute kidney injury (9.8%). Gross hematuria appeared after biopsy in less than 5% of the patients, but none of them needed blood transfusion. Adequate renal tissue sample was obtained in 95.5% of the renal biopsies. Primary glomerulonephritis (GN) was the most common finding (61.4%), followed by secondary GN (21.4%), tubulointerstitial diseases (3.7%) and hereditary nephropathy (2.8%), while in 10.7% of the cases, normal renal tissues were found. According to histopathological diagnosis, the most common causes of primary GN were IgA nephropathy (20.9%), followed by minimal change disease (18.1%) and focal segmental glomerulosclerosis (11.6%). The epidemiology of glomerular disease in our single-center cohort is similar to that shown in other national and international reports. Moreover, our study shows that percutaneous ultrasound-guided RB is a safe, reliable and effective technique in children.

  15. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  16. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  17. First use of a truly-hybrid x-ray/MR imaging system for guidance of brain biopsy

    International Nuclear Information System (INIS)

    Fahrig, R.; Daniel, B.L.; Butts, K.; Pelc, N.J.; Heit, G.; Wen, Z.

    2003-01-01

    The use of a new hybrid imaging system for guidance of a brain biopsy is described. The system combines the strengths of MRI (soft-tissue contrast, arbitrary plane selection) with those of x-ray fluoroscopy (high-resolution real-time projection images, clear portrayal of bony structures) and allows switching between the imaging modalities without moving the patient. The biopsy was carried out using x-ray guidance for direction of the needle through the foramen ovale and MR guidance to target the soft-tissue lesion. Appropriate samples were acquired. The system could be particularly effective for guidance of those cases where motion, swelling, resection and other intra-operative anatomical changes cannot be accounted for using traditional stereotactic-based imaging approaches. (author)

  18. The importance of preoperative tissue sampling for mobile spine chordomas: literature review and report of two cases.

    Science.gov (United States)

    Zuccato, Jeffrey A; Witiw, Christopher D; Keith, Julia; Dyer, Erin; Saghal, Arjun; da Costa, Leodante

    2018-01-01

    Pre-operative biopsy and diagnosis of chordomas of the mobile spine is indicated as en bloc resections improve outcomes. This review of the management of mobile spine chordomas includes two cases of unexpected mobile spine chordomas where a preoperative tissue diagnosis was decided against and may have altered surgical decision-making. Two lumbar spine chordomas thought to be metastatic and primary bony lesions preoperatively were not biopsied before surgery and eventual pathology revealed chordoma. Preoperative diagnoses were questioned during surgery after an intraoperative tissue diagnosis of chordoma in one case and unclear pathology with non-characteristic tumor morphology in the other. The surgical plan was altered in these cases to maximize resection as en bloc resection reduces the risk of local recurrence in chordoma. Mobile spine chordomas are rare and en bloc resection is recommended, contrary to the usual approach to more common spine tumors. Since en bloc resection of spine chordomas improves disease free survival, it has been recommended that tissue diagnosis be obtained preoperatively when chordoma is considered in the differential diagnosis, in order to guide surgical planning. We present two cases where a preoperative biopsy was considered but not obtained after neuroradiology consultation and imaging review, which may have been managed differently if the diagnosis of spine chordomas were known pre-operatively.

  19. Utility of Tissue Transglutaminase Immunohistochemistry in Pediatric Duodenal Biopsies: Patterns of Expression and Role in Celiac Disease—A Clinicopathologic Review

    Directory of Open Access Journals (Sweden)

    Saeeda Almarzooqi

    2013-01-01

    Full Text Available Tissue transglutaminase (tTG is a ubiquitous multifunctional protein. It has roles in various cellular processes. tTG is a major target of autoantibodies in celiac disease, and its expression by immunohistochemistry in pediatric celiac disease has not been fully examined. We studied tTG expression in 78 pediatric duodenal biopsies by utilizing an antibody to transglutaminase 2. Serum tTG was positive in all celiac cases evaluated. Serum antiserum endomysial antibody (EMA and tTG were negative in all control subjects and in inflammatory bowel disease and eosinophilic gastroenteritis. There was a statistically significant difference between cases of celiac disease and normal controls in terms of tTG immunohistochemical staining in duodenal biopsies surface epithelium ( value = 0.0012. There was no significant statistical difference in terms of staining of the villous surface or crypt between the cases of celiac disease and cases with IBD ( value = 0.5970 and 0.5227, resp.. There was no detected correlation between serum tTG values and immunohistochemical positivity on duodenal biopsy in cases of celiac disease ( value = 1. There was no relationship between Marsh classification and positivity of villous surface for tTG ( value = 0.4955. We conclude that tTG has limited utility in diagnosis of celiac disease in pediatric duodenal biopsies.

  20. Ultraviolet-fluorescent tattoo location of cutaneous biopsy site.

    Science.gov (United States)

    Chuang, Gary S; Gilchrest, Barbara A

    2012-03-01

    Cutaneous biopsies often heal with little or no scarring. Prior studies have shown an alarming percentage of patients who incorrectly identify biopsy sites at the time of surgery. To investigate the safety and utility of an ultraviolet (UV)-fluorescent tattoo for biopsy site identification. A preclinical proof of concept was established with skin culture. An UV-fluorescent tattoo was applied to discarded neonatal foreskin in culture medium. The stability of the tattooed skin was examined clinically and histologically. One patient with a recurrent basal cell carcinoma in a difficult-to-identify location underwent tattoo application at the time of biopsy to demarcate the site. The patient was monitored for tattoo reaction and referred for surgical excision. The cultured tissue exhibited stable UV fluorescence with daily washing. Tissue histology demonstrated tattoo particles lining the skin edge under fluorescent microscopy. The patient was reluctant to undergo another surgical procedure and instead returned to our clinic at 3 months and 17 months after the biopsy for management of other tumors. The patient had no symptoms of allergic reaction to the tattoo dye. The fluorescent tattoo remains invisible under visible light and visible only under Wood's light. The present study documents the utility of an UV-fluorescent tattoo to locate a biopsy site. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  1. Proteome stability analysis of snap frozen, RNAlater preserved, and formalin-fixed paraffin-embedded human colon mucosal biopsies

    Directory of Open Access Journals (Sweden)

    Tue Bjerg Bennike

    2016-03-01

    Full Text Available Large repositories of well characterized RNAlater preserved samples and formalin-fixed, paraffin-embedded samples have been generated worldwide. However, the impact on the proteome of the preservation methods remain poorly described. Therefore, we analyzed the impact on the proteome of preserving samples in RNAlater, and by formalin-fixation, paraffin-embedding on human soft tissue, using directly frozen samples as a control (“Comparing the proteome of snap frozen, RNAlater preserved, and formalin-fixed paraffin-embedded human tissue samples” [1]. We here report the data from the analysis. The comparative analysis was performed on 24 colon mucosa biopsies, extracted from the sigmoideum of two gastroenterologically healthy participants for the purpose of this study. A set of biopsies were additionally stored for 30 min at room temperature prior to formalin-fixation. The samples were analyzed by high throughput gel free quantitative proteomics. The MS proteomics data have been deposited to the ProteomeXchange Consortium via the PRIDE partner repository with the dataset identifier PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD002029. Keywords: Human, Colon, Mucosa, RNAlater, FFPE, Snap-frozen, Stability, LC–MS, Proteomics

  2. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  3. Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.

    Science.gov (United States)

    Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C

    2015-01-01

    Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.

  4. In-air micro-pixe analysis of tissue samples

    International Nuclear Information System (INIS)

    Tanaka, A.; Ishii, K.; Komori, Y.

    2002-01-01

    Micro-PIXE is capable of providing spatial distributions of elements in the micro-meter scale and its application to biology is useful to elucidate the cellular metabolism. Since, in this method, a sample target is usually irradiated with proton or α-particle beams in vacuum, beam heating results in evaporation of volatile elements an shrinking of the sample. In order to avoid these side effects, we previously developed a technique of in-air micro-PIXE analysis for samples of cultured cells. In addition to these, analysis of exposed tissue samples from living subjects is highly desirable in biological and medical research. Here, we describe a technique of in-air micro-PIXE analysis of such tissue samples. The target samples of exposed tissue slices from a Donryu rat, in which a tumor had been transplanted, were analyzed with proton micro-beams of 2.6 MeV. We report that the shape of cells and the distribution of volatile elements in the tissue sample remain uncharged when using a target preparation based on a freeze-drying method. (author)

  5. TP53 Staining in Tissue Samples of Chronic Lymphocytic Lymphoma Cases: An Immunohistochemical Survey of 51 Cases

    Directory of Open Access Journals (Sweden)

    İbrahim Kulaç

    2017-03-01

    Full Text Available Objective: Chronic lymphocytic leukemia (CLL is the most common lymphoproliferative disease in adults. The aim of this study is to find out if the extent of proliferation centers or the immunohistochemical expression of p53 is related to disease prognosis. Materials and Methods: In the scope of this study, 54 biopsy specimens from 51 patients (50 of lymph nodes; the others of spleen, tonsil, orbit, and liver diagnosed with CLL at the Hacettepe University Department of Pathology in 2000-2013 were reevaluated. The clinical and demographic data of the patients were obtained from our patient database. Biopsy samples were assessed semi-quantitatively for the percentage of proliferation center/total biopsy area (PC/TBA and an immunohistochemical study was performed on representative blocks of tissues for p53 expression. Results: When the patients were divided into two categories according to Rai stage as high and low (stages 0, 1, and 2 vs. stages 3 and 4, it was seen that patients with low Rai stage had a better prognosis than those with high stages (p=0.030. However, there was no statistically significant correlation between overall survival and PC/TBA ratio or p53 expression levels. Conclusion: In our cohort, PC/TBA ratio and immunopositivity of p53 did not show correlations with overall survival.

  6. Should warfarin or aspirin be stopped prior to prostate biopsy? An analysis of bleeding complications related to increasing sample number regimes

    International Nuclear Information System (INIS)

    Chowdhury, R.; Abbas, A.; Idriz, S.; Hoy, A.; Rutherford, E.E.; Smart, J.M.

    2012-01-01

    Aim: To determine whether patients undergoing transrectal ultrasound (TRUS)-guided prostate biopsy with increased sampling numbers are more likely to experience bleeding complications and whether warfarin or low-dose aspirin are independent risk factors. Materials and methods: 930 consecutive patients with suspected prostatic cancer were followed up after biopsy. Warfarin/low-dose aspirin was not stopped prior to the procedure. An eight to 10 sample regime TRUS-guided prostate biopsy was performed and patients were offered a questionnaire to complete 10 days after the procedure, to determine any immediate or delayed bleeding complications. Results: 902 patients returned completed questionnaires. 579 (64.2%) underwent eight core biopsies, 47 (5.2%) underwent nine, and 276 (30.6%) underwent 10. 68 were taking warfarin [mean international normalized ratio (INR) = 2.5], 216 were taking low-dose aspirin, one was taking both, and 617 were taking neither. 27.9% of those on warfarin and 33.8% of those on aspirin experienced haematuria. 37% of those on no blood-thinning medication experienced haematuria. 13.2% of those on warfarin and 14.4% of those on aspirin experienced rectal bleeding. 11.5% of those on no blood-thinning medication experienced rectal bleeding. 7.4% of those on warfarin and 12% of those on aspirin experienced haematospermia. 13.8% of those on neither experienced haematospermia. Regression analysis showed a significant association between increasing sampling number and occurrence of all bleeding complication types. There was no significant association between minor bleeding complications and warfarin use; however, there was a significant association between minor bleeding complications and low-dose aspirin use. There was no severe bleeding complication. Conclusion: There is an increased risk of bleeding complications following TRUS-guided prostate biopsy with increased sampling numbers but these are minor. There is also an increased risk with low

  7. Vacuum biopsy of the breast. Experience of St-Jan Hospital in Brugge

    International Nuclear Information System (INIS)

    Steyaert, L.; Van Kerkhove, F.; Casselman, J.

    2004-01-01

    Background. Mammotome is a percutaneous biopsy technique with a large needle, assisted by vacuum aspiration. The single insertion technique allows to collect multiple large tissue samples, which gives a more reliable histological result. The technique can be used under stereotactic, MRI or ultrasound guidance. The technique is used under local anesthesia, on an outpatient basis. Conclusions. Altough it is essentially a diagnostic technique, it has a therapeutic potential in some cases. Recently, the technique has been FDA approved for the removal of benign nodular lesions. Worldwide, over 2 million procedures have already been performed. It has the potential to replace surgical open biopsy, with a similar accuracy and at a lower cost, and it is less invasive. (author)

  8. SEM investigation of heart tissue samples

    International Nuclear Information System (INIS)

    Saunders, R; Amoroso, M

    2010-01-01

    We used the scanning electron microscope to examine the cardiac tissue of a cow (Bos taurus), a pig (Sus scrofa), and a human (Homo sapiens). 1mm 3 blocks of left ventricular tissue were prepared for SEM scanning by fixing in 96% ethanol followed by critical point drying (cryofixation), then sputter-coating with gold. The typical ridged structure of the myofibrils was observed for all the species. In addition crystal like structures were found in one of the samples of the heart tissue of the pig. These structures were investigated further using an EDVAC x-ray analysis attachment to the SEM. Elemental x-ray analysis showed highest peaks occurred for gold, followed by carbon, oxygen, magnesium and potassium. As the samples were coated with gold for conductivity, this highest peak is expected. Much lower peaks at carbon, oxygen, magnesium and potassium suggest that a cystallized salt such as a carbonate was present in the tissue before sacrifice.

  9. SEM investigation of heart tissue samples

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, R; Amoroso, M [Physics Department, University of the West Indies, St. Augustine, Trinidad and Tobago, West Indies (Trinidad and Tobago)

    2010-07-01

    We used the scanning electron microscope to examine the cardiac tissue of a cow (Bos taurus), a pig (Sus scrofa), and a human (Homo sapiens). 1mm{sup 3} blocks of left ventricular tissue were prepared for SEM scanning by fixing in 96% ethanol followed by critical point drying (cryofixation), then sputter-coating with gold. The typical ridged structure of the myofibrils was observed for all the species. In addition crystal like structures were found in one of the samples of the heart tissue of the pig. These structures were investigated further using an EDVAC x-ray analysis attachment to the SEM. Elemental x-ray analysis showed highest peaks occurred for gold, followed by carbon, oxygen, magnesium and potassium. As the samples were coated with gold for conductivity, this highest peak is expected. Much lower peaks at carbon, oxygen, magnesium and potassium suggest that a cystallized salt such as a carbonate was present in the tissue before sacrifice.

  10. RAS testing of liquid biopsy correlates with the outcome of metastatic colorectal cancer patients treated with first-line FOLFIRI plus cetuximab in the CAPRI-GOIM trial.

    Science.gov (United States)

    Normanno, N; Esposito Abate, R; Lambiase, M; Forgione, L; Cardone, C; Iannaccone, A; Sacco, A; Rachiglio, A M; Martinelli, E; Rizzi, D; Pisconti, S; Biglietto, M; Bordonaro, R; Troiani, T; Latiano, T P; Giuliani, F; Leo, S; Rinaldi, A; Maiello, E; Ciardiello, F

    2018-01-01

    Liquid biopsy is an alternative to tissue for RAS testing in metastatic colorectal carcinoma (mCRC) patients. Little information is available on the predictive role of liquid biopsy RAS testing in patients treated with first-line anti-EGFR monoclonal antibody-based therapy. In the CAPRI-GOIM trial, 340 KRAS exon-2 wild-type mCRC patients received first-line cetuximab plus FOLFIRI. Tumor samples were retrospectively assessed by next generation sequencing (NGS). Baseline plasma samples were analyzed for KRAS and NRAS mutations using beads, emulsion, amplification, and magnetics digital PCR (BEAMing). Discordant cases were solved by droplet digital PCR (ddPCR) or deep-sequencing. A subgroup of 92 patients with available both NGS data on tumor samples and baseline plasma samples were included in this study. Both NGS analysis of tumor tissue and plasma testing with BEAMing identified RAS mutations in 33/92 patients (35.9%). However, 10 cases were RAS tissue mutant and plasma wild-type, and additional 10 cases were tissue wild-type and plasma mutant, resulting in a concordance rate of 78.3%. Analysis of plasma samples with ddPCR detected RAS mutations in 2/10 tissue mutant, plasma wild-type patients. In contrast, in all tissue wild-type and plasma mutant cases, ddPCR or deep-sequencing analysis of tumor tissue confirmed the presence of RAS mutations at allelic frequencies ranging between 0.15% and 1.15%. The median progression-free survival of RAS mutant and wild-type patients according to tissue (7.9 versus 12.6 months; P = 0.004) and liquid biopsy testing (7.8 versus 13.8 moths; P < 0.001) were comparable. Similar findings were observed for the median overall survival of RAS mutant and wild-type patients based on tissue (22.1 versus 35.8 months; P = 0.016) and plasma (19.9 versus 35.8 months; P = 0.013) analysis. This study indicates that RAS testing of liquid biopsy results in a similar outcome when compared with tissue testing in mCRC patients

  11. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  12. Laparoscopic ovarian biopsy pick-up method for goats.

    Science.gov (United States)

    Brandão, Fabiana A S; Alves, Benner G; Alves, Kele A; Souza, Samara S; Silva, Yago P; Freitas, Vicente J F; Teixeira, Dárcio I A; Gastal, Eduardo L

    2018-02-01

    Biopsy pick-up (BPU) has been considered a safe method to harvest ovarian fragments from live animals. However, no studies have been reported on the use of BPU to collect in vivo ovarian tissue in goats. The goals of this study were: (i) to test different biopsy needle sizes to collect ovarian tissue in situ using the BPU method (Experiment 1), and (ii) to study ovarian tissue features such as preantral follicle density, morphology, class distribution, and stromal cell density in ovarian fragments obtained in vivo through a laparoscopic BPU method (Experiment 2). In Experiment 1, goat ovaries (n = 20) were collected in a slaughterhouse and subjected to in situ BPU. Three needles (16, 18, and 20G) were tested. In Experiment 2, the most efficient biopsy needle from Experiment 1 was used to perform laparoscopic BPU in goats (n = 8). In Experiment 1, the recovery rate was greater (P rate). Overall, 2054 preantral follicles were recorded in 5882 histological sections analyzed. Mean preantral follicular density was 28.4 ± 1.3 follicles per cm 2 . The follicular density differed (P rate in goats. Furthermore, this study described for the first time that goat ovarian biopsy fragments have a high heterogeneity in follicular density, morphology, class distribution, and stromal cell density. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  14. Is the Diagnosis of Celiac Disease Possible Without Intestinal Biopsy?

    Directory of Open Access Journals (Sweden)

    Maha Shomaf

    2017-08-01

    Full Text Available Background: Coeliac disease is defined as a state of immune-mediated hyper-responsiveness to dietary gluten from wheat, barley, or rye in genetically predisposed individuals that results in tissue damage. The diagnosis is made by microscopic examination of a small intestinal biopsy, although serological testing for antibodies against tissue transglutaminase and deamidated gliadin peptide can be of great advantage. It has been suggested that duodenal biopsy can be avoided in patients with high levels of the tissue transglutaminase antibody, since a relationship has been found to be present between tissue transglutaminase antibody titres and coeliac disease. Aims: To study the correlation between tissue transglutaminase titre and small intestinal biopsy findings in patients with coeliac disease. Study Design: Diagnostic accuracy study. Methods: Ninety-five cases of patients diagnosed with coeliac disease and with positive serum tissue transglutaminase titres were retrieved from the Jordan University Hospital archives between December 2014 and December 2015. All the cases were classified according to the Marsh classification. Results: Ninety-five cases with a positive titre for the antibody were included in this study, 73 (76.8% of them were females and 22 cases (23.2% were males. The age of the patients ranged between 4 and 75 years with a mean age ± standard deviation of 32.3±14.7. The sensitivity was the highest in Marsh IIIC and lowest in Marsh IIIA (95% versus 68% respectively. The specificity was moderate (76% for all subtypes of Marsh III. Conclusion: This study showed a positive correlation between the tissue transglutaminase titre and the degree of duodenal damage (Marsh IIIC in patients with coeliac disease. In the presence of high tissue transglutaminase levels, duodenal biopsy might not be always necessary for diagnosis, particularly in symptomatic patients

  15. The proportion of prostate biopsy tissue with Gleason pattern 4 or 5 predicts for biochemical and clinical outcome after radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    D'Ambrosio, David J.; Hanlon, Alexandra L.; Al-Saleem, Tahseen; Feigenberg, Steven J.; Horwitz, Eric M.; Uzzo, Robert G.; Pollack, Alan; Buyyounouski, Mark K.

    2007-01-01

    Purpose: To investigate the prognostic utility of the proportion of prostate biopsy tissue containing Gleason pattern 4 or 5 (GP4/5) after definitive radiotherapy (RT) for prostate cancer. Methods and Materials: A total of 568 patients with T1c-3 Nx/0 prostate cancer who received three-dimensional conformal RT alone between May 1989 and August 2001 were studied. There were 161 men with Gleason score 7-10 disease. The GP4/5 was defined as the percentage of biopsy tissue containing Gleason pattern 4 or 5. A Cox proportional hazards model was used for univariate and multivariate analyses (MVA) for biochemical failure (BF) (American Society of Therapeutic Radiology and Oncology definition) and distant metastasis (DM). A recursive partitioning analysis was done using the results of the MVA to identify a cutpoint for GP4/5. Results: The median follow-up was 46 (range, 13-114) months and median RT dose was 76 (range, 65-82) Gy. On MVA, increasing initial prostate-specific antigen (p = 0.0248) decreasing RT dose (continuous, p = 0.0022), T stage (T1/2 vs. T3) (p = 0.0136) and GP4/5 (continuous, p < 0.0001) were significant predictors of BF in a model also containing GS. GP4/5 was the only significant predictor of DM in the same model (p < 0.0001). Conclusion: The GP4/5 in prostate biopsy specimens is a predictor of BF and DM after RT independent of Gleason score. This parameter should be reported by the pathologist when reviewing prostatic biopsy specimens

  16. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  17. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo

    2017-01-01

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications

  18. Feasibility and effectiveness of image-guided percutaneous biopsy of the urinary bladder.

    Science.gov (United States)

    Butros, Selim Reha; McCarthy, Colin James; Karaosmanoğlu, Ali Devrim; Shenoy-Bhangle, Anuradha S; Arellano, Ronald S

    2015-08-01

    To evaluate the indications, technique, results, and complications of image-guided percutaneous biopsy of the urinary bladder. This retrospective study included 15 patients (10 male, 5 female) who underwent image-guided percutaneous biopsy of the urinary bladder between January 1999 and December 2013. The medical records, imaging studies, procedural details, and long-term follow-up of each patient were reviewed in detail to assess the feasibility of percutaneous bladder biopsy. Ten patients had focal bladder masses and 5 patients had asymmetric or diffuse bladder wall thickening. Eleven patients had either negative or unsatisfactory cystoscopies prior to the biopsy. Percutaneous biopsies were performed under computed tomography guidance in 12 patients and ultrasound in 3 patients. All procedures were technically successful and there were no procedural complications. Malignancy was confirmed in 8 patients, among whom 6 had transitional cell carcinoma, 1 cervical cancer, and 1 prostate cancer metastasis. Seven patients had a benign diagnosis, including 3 that were later confirmed by pathology following surgery and 2 patients with a false-negative result. The overall sensitivity was 80% and accuracy was 87%. Image-guided percutaneous biopsy of the urinary bladder is a safe and technically feasible procedure with a high sensitivity and accuracy rate. Although image-guided bladder biopsy is an uncommon procedure, it should be considered in selected cases when more traditional methods of tissue sampling are either not possible or fail to identify abnormalities detected by cross-sectional imaging.

  19. Mixed germ cell tumor of mediastinum/lung masquerading as hemangioma in fine needle biopsy

    Directory of Open Access Journals (Sweden)

    Rathna Nuti

    2013-01-01

    Full Text Available The histological predominance of one component in a germ cell tumor can lead to a mistaken diagnosis. Here, we describe a mediastinal teratoma with predominant vascular proliferation (>90% which on fine needle biopsy was diagnosed as a pulmonary hemangioma. Later, resection specimen revealed other components constituting ~4%, changing the diagnosis while illustrating theimportance of careful evaluation. A 37-year-old Caucasian male with shortness of breath, weight loss, and history of recently resolved pneumonia was diagnosed with hemangioma, after a computed tomography guided fine needle biopsy of a -16.3-cm mediastinal pulmonary mass revealed abundant benign vascular elements. Following tumor excision, ~94% of the sample exhibited predominant vascular elementsThe mass also exhibited rare focal areas of malignant epithelium in a reticular arrangement and undifferentiated pleomorphic cells associated with vascular invasion. These atypical epithelial cells were positive for CD30, pan CK, AFP, β-HCG and CD 117, thusprocuring a diagnosis of mediastinal mixed germ cell tumor. Although mixed germ cell tumors consist of various tissue types, diagnosis can be easily overlooked if one component dominates. Therefore, obtaining adequate representative neoplasm samples, and sectioning the samples thoroughly, searching for coexisting tissue types is critical for accurate diagnosis.

  20. Ultrasound-guided, vacuum-assisted biopsy in evaluation of breast lesions

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Dyczek, S.; Skotnicki, P.; Stelmach, A.; Herman, K.

    2008-01-01

    Aim. Evaluation of the efficacy of ultrasound-guided vacuum-assisted biopsy for the verification of breast lesions. Introduction. Ultrasound breast examination is a noninvasive method of breast imaging. It is adjunct to mammography and physical examination and, in women under 30 years of age, pregnant and lactating, it is the basic examination used for the detection and diagnosing of breast diseases. It allows also to obtain cells or tissue samples with such minimally invasive techniques as fine-needle biopsy, core needle biopsy or vacuum-assisted biopsy. Material and methods. The study group consisted of 138 women, aged from 20 to 76 years, who underwent ultrasound guided vacuum-assisted biopsy between March and December 2006. Because double lesions were diagnosed in 6 patients, this resulted in 144 performed procedures. Each patient underwent ultrasound examination, performed with a 10-12 MHz transducer. Biopsies were guided by a 12 MHz transducer and performed with the Mammotome System using an 11G or an 8G needle, depending upon the size and site of the lesion. Obtained data were compared using the Chi-square test; p values of less than 0.05 were considered indicative of a significant difference. Results. The average size of the biopted lesions was estimated as 11±3,8 mm (range: 4-30 mm). However, lesions described by radiologists as apparently suspicious were not qualified for the vacuum-assisted biopsy, in the tested material 4 lesions appeared to be carcinomas (3 were invasive breast carcinomas and 1 was ductal carcinoma in situ). When compared with other changes, these lesions were most frequently equivocal (3 vs 1 determined as benign, p=0.014). There was no statistically significant difference in echogenicity (3 hypoechoic vs 1 with mixed echogenicity) nor in the shape (1 oval change, 2 lobulated and 1 irregular). Pathological examination revealed 86 cases of fibroadenoma within the tested material. Those lesions were mostly benign (77 vs 9 equivocal

  1. Magnetic resonance elastography is as accurate as liver biopsy for liver fibrosis staging.

    Science.gov (United States)

    Morisaka, Hiroyuki; Motosugi, Utaroh; Ichikawa, Shintaro; Nakazawa, Tadao; Kondo, Tetsuo; Funayama, Satoshi; Matsuda, Masanori; Ichikawa, Tomoaki; Onishi, Hiroshi

    2018-05-01

    Liver MR elastography (MRE) is available for the noninvasive assessment of liver fibrosis; however, no previous studies have compared the diagnostic ability of MRE with that of liver biopsy. To compare the diagnostic accuracy of liver fibrosis staging between MRE-based methods and liver biopsy using the resected liver specimens as the reference standard. A retrospective study at a single institution. In all, 200 patients who underwent preoperative MRE and subsequent surgical liver resection were included in this study. Data from 80 patients were used to estimate cutoff and distributions of liver stiffness values measured by MRE for each liver fibrosis stage (F0-F4, METAVIR system). In the remaining 120 patients, liver biopsy specimens were obtained from the resected liver tissues using a standard biopsy needle. 2D liver MRE with gradient-echo based sequence on a 1.5 or 3T scanner was used. Two radiologists independently measured the liver stiffness value on MRE and two types of MRE-based methods (threshold and Bayesian prediction method) were applied. Two pathologists evaluated all biopsy samples independently to stage liver fibrosis. Surgically resected whole tissue specimens were used as the reference standard. The accuracy for liver fibrosis staging was compared between liver biopsy and MRE-based methods with a modified McNemar's test. Accurate fibrosis staging was achieved in 53.3% (64/120) and 59.1% (71/120) of patients using MRE with threshold and Bayesian methods, respectively, and in 51.6% (62/120) with liver biopsy. Accuracies of MRE-based methods for diagnoses of ≥F2 (90-91% [108-9/120]), ≥F3 (79-81% [95-97/120]), and F4 (82-85% [98-102/120]) were statistically equivalent to those of liver biopsy (≥F2, 79% [95/120], P ≤ 0.01; ≥F3, 88% [105/120], P ≤ 0.006; and F4, 82% [99/120], P ≤ 0.017). MRE can be an alternative to liver biopsy for fibrosis staging. 3. Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1268-1275. © 2017

  2. A randomised pilot study comparing 13 G vacuum-assisted biopsy and conventional 14 G core needle biopsy of axillary lymph nodes in women with breast cancer

    International Nuclear Information System (INIS)

    Maxwell, A.J.; Bundred, N.J.; Harvey, J.; Hunt, R.; Morris, J.; Lim, Y.Y.

    2016-01-01

    Aim: To compare the acceptability, safety, and feasibility of vacuum-assisted biopsy (VAB) and core needle biopsy (CNB) of axillary lymph nodes in women with breast cancer. Materials and methods: This parallel, non-blinded, randomised study was approved by the National Research Ethics Service. Following written informed consent, women with abnormal appearing axillary lymph nodes and radiologically malignant breast masses were randomised 1:1 to lymph node sampling under local anaesthetic with either 14 G CNB or 13 G VAB in a single UK centre. Primary outcomes were study uptake rate and patient willingness to undergo a repeat procedure if necessary. Procedure duration, immediate and post-procedure pain scores, diagnostic yield, complications, and surgical histopathology were recorded. Results: Ninety-five women were approached; 81 (85.3%) consented and were randomised. Forty underwent CNB; 40 underwent VAB; one was excluded. Median age was 57 years. The median procedure time was 2 minutes for both techniques. The median number of samples obtained was three for CNB and four for VAB. Median pain scores for the procedure and first 3 days were 1/10 and 1/10 for CNB and 1/10 and 2/10 for VAB (p=0.11 and 0.04). More women were prepared to undergo repeat CNB compared to VAB, but the difference was not significant (38/39 versus 33/39; p=0.11). Two patients developed a haematoma after VAB. One CNB and six VABs failed to yield adequate tissue (p=0.11), but the sensitivity was similar at 79% and 78%. Conclusion: Study uptake was high. Acceptability of the two procedures was similar, but VAB was associated with more post-procedure pain. The sensitivity appears to be similar. - Highlights: • Vacuum biopsy of axillary lymph nodes can be performed rapidly. • Post-procedure pain was slightly higher in women who underwent vacuum biopsy. • The inadequate yield rate of vacuum biopsy may be higher than that for core biopsy. • Sensitivity of 13-gauge vacuum biopsy and 14-gauge

  3. Muscle biopsies off-set normal cellular signaling in surrounding musculature

    DEFF Research Database (Denmark)

    Krag, Thomas O; Hauerslev, Simon; Dahlqvist, Julia R

    2013-01-01

    muscle tissue for at least 3 weeks after the biopsy was performed and magnetic resonance imaging suggests that an effect of a biopsy may persist for at least 5 months. Cellular signaling after a biopsy resembles what is seen in severe limb-girdle muscular dystrophy type 2I with respect to protein......Studies of muscle physiology and muscular disorders often require muscle biopsies to answer questions about muscle biology. In this context, we have often wondered if muscle biopsies, especially if performed repeatedly, would affect interpretation of muscle morphology and cellular signaling. We...... hypothesized that muscle morphology and cellular signaling involved in myogenesis/regeneration and protein turnover can be changed by a previous muscle biopsy in close proximity to the area under investigation. Here we report a case where a past biopsy or biopsies affect cellular signaling of the surrounding...

  4. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  5. Dual p16 and Ki-67 Expression in Liquid-Based Cervical Cytological Samples Compared to Pap Cytology Findings, Biopsies, and HPV Testing in Cervical Cancer Screening: A Diagnostic Accuracy Study.

    Science.gov (United States)

    Prigenzi, Karla Calaça Kabbach; Heinke, Thaís; Salim, Rafael Calil; Focchi, Gustavo Rubino de Azevedo

    2018-01-01

    Our objective was to verify the sensitivity and specificity of dual immunocytochemistry staining for p16 and Ki-67 in liquid-based samples (the "dual" assay) for cervical lesion screening, compared to biopsy findings and human papillomavirus (HPV) DNA molecular detection. Sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values for the "dual immunocytochemistry assay" were calculated and compared to histopathological results and to high-risk HPV DNA detection in adult women or teenagers submitted to cervical cancer screening. A total of 151 women were included. The majority (96.2%) of those with negative dual assay results had lower biopsy grades (p cytology results suggestive of cervical cancer had positive dual immunocytochemistry assay results more frequently (p < 0.001), and these positive results were also significantly associated with biopsy findings (p < 0.001) and with high-risk genotype HPV infection (p = 0.007). Specificity and PPV for the dual assay were 0.972 (0.855-0.999) and 0.800 (0.284-0.995), respectively, and 1.000 (0.590-1.000) and 1.000 (0.631-1.000) for HPV detection. The dual immunocytochemistry assay had high specificity and PPV. It reveals a persistent HPV infection, avoiding the need for new tissue collections for biopsies or hybrid capture. © 2018 S. Karger AG, Basel.

  6. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  7. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  8. Estrogen and progesterone receptor levels in nonneoplastic breast epithelium of breast cancer cases versus benign breast biopsy controls

    International Nuclear Information System (INIS)

    Woolcott, Christy G; SenGupta, Sandip K; Hanna, Wedad M; Aronson, Kristan J

    2008-01-01

    Previous studies and biological mechanisms of carcinogenesis suggest that the steroid receptor content of benign breast epithelium may be related to breast cancer risk. The objective in this study was to compare the levels of estrogen receptor-α (ER) and progesterone receptor (PR) in nonneoplastic breast epithelium between breast cancer cases and biopsy controls. Between 1995 and 1997 at two sites (Women's College Hospital in Toronto and Kingston General Hospital), 667 women who were scheduled for diagnostic excisional breast biopsies completed a questionnaire providing personal information and agreed to allow analysis of routinely resected tissue. Histological slides with nonneoplastic epithelium were available for 101 cancer cases and 200 biopsy controls in Toronto and for 105 cancer cases and 119 controls in Kingston. Nonneoplastic epithelium was examined with immunohistochemical assays to determine the percent of epithelial cells staining for ER and PR. Unconditional logistic regression was used to calculate odds ratios (OR) stratified by study site. The ER content of nonneoplastic tissue was higher in cases than biopsy controls in unadjusted analyses; after adjustment for age, however, a weak association remained in only one of the study sites. After adjustment for age, the PR content of nonneoplastic tissue was slightly lower in breast cancer cases than controls in one study site. Furthermore, this inverse association was confined to women with PR negative breast cancer in comparison to the controls. No interaction between ER and PR content of nonneoplastic tissue was observed in relation to the odds of having breast cancer. The results of this study are consistent with only a slight indication of increased ER levels in nonneoplastic tissue in breast cancer cases relative to controls. This study contributes to the understanding of breast cancer by examining both ER and PR in nonneoplastic tissue. Limitations remain, however, such as the necessity of

  9. Influence of parasite density and sample storage time on the reliability of Entamoeba histolytica-specific PCR from formalin-fixed and paraffin-embedded tissues.

    Science.gov (United States)

    Frickmann, Hagen; Tenner-Racz, Klara; Eggert, Petra; Schwarz, Norbert G; Poppert, Sven; Tannich, Egbert; Hagen, Ralf M

    2013-12-01

    We report on the reliability of polymerase chain reaction (PCR) for the detection of Entamoeba histolytica from formalin-fixed, paraffin-embedded tissue in comparison with microscopy and have determined predictors that may influence PCR results. E. histolytica-specific and Entamoeba dispar-specific real-time PCR and microscopy from adjacent histologic sections were performed using a collection of formalin-fixed, paraffin-embedded tissue specimens obtained from patients with invasive amebiasis. Specimens had been collected during the previous 4 decades. Association of sample age, parasite density, and reliability of PCR was analyzed. E. histolytica PCR was positive in 20 of 34 biopsies (58.8%); 2 of these 20 were microscopically negative for amebae in neighboring tissue sections. PCR was negative in 9 samples with visible amebae in neighboring sections and in 5 samples without visible parasites in neighboring sections. PCR was negative in all specimens that were older than 3 decades. Low parasite counts and sample ages older than 20 years were predictors for false-negative PCR results. All samples were negative for E. dispar DNA. PCR is suitable for the detection of E. histolytica in formalin-fixed, paraffin-embedded tissue samples that are younger than 2 decades and that contain intermediate to high parasite numbers. Negative results in older samples were due to progressive degradation of DNA over time as indicated by control PCRs targeting the human 18S rRNA gene. Moreover, our findings support previous suggestions that only E. histolytica but not E. dispar is responsible for invasive amebiasis.

  10. Feasibility of full-field optical coherence microscopy in ultra-structural imaging of human colon tissues

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Eun Seo [Chosun University, Gwangju (Korea, Republic of); Choi, Woo June; Ryu, Seon Young; Lee, Byeong Ha [Gwangju Institute of Science and Technology, Gwangju (Korea, Republic of); Lee, Jae Hyuk; Bom, Hee Seung; Lee, Byeong Il [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2010-06-15

    We demonstrated the imaging feasibility of full-field optical coherence microscopy (FF-OCM) in pathological diagnosis of human colon tissues. FF-OCM images with high transverse resolution were obtained at different depths of the samples without any dye staining or physical slicing, and detailed microstructures of human colon tissues were visualized. Morphological differences in normal tissues, cancer tissues, and tissues under transition were observed and matched with results seen in conventional optical microscope images. The optical biopsy based on FF-OCM could overcome the limitations on the number of physical cuttings of tissues and could perform high-throughput mass diagnosis of diseased tissues. The proved utility of FF-OCM as a comprehensive and efficient imaging modality of human tissues showed it to be a good alternative to conventional biopsy.

  11. Feasibility of full-field optical coherence microscopy in ultra-structural imaging of human colon tissues

    International Nuclear Information System (INIS)

    Choi, Eun Seo; Choi, Woo June; Ryu, Seon Young; Lee, Byeong Ha; Lee, Jae Hyuk; Bom, Hee Seung; Lee, Byeong Il

    2010-01-01

    We demonstrated the imaging feasibility of full-field optical coherence microscopy (FF-OCM) in pathological diagnosis of human colon tissues. FF-OCM images with high transverse resolution were obtained at different depths of the samples without any dye staining or physical slicing, and detailed microstructures of human colon tissues were visualized. Morphological differences in normal tissues, cancer tissues, and tissues under transition were observed and matched with results seen in conventional optical microscope images. The optical biopsy based on FF-OCM could overcome the limitations on the number of physical cuttings of tissues and could perform high-throughput mass diagnosis of diseased tissues. The proved utility of FF-OCM as a comprehensive and efficient imaging modality of human tissues showed it to be a good alternative to conventional biopsy.

  12. Biopsy Diagnosis of Oral Carcinoma by the Combination of Morphological and Spectral Methods Based on Embedded Relay Lens Microscopic Hyperspectral Imaging System.

    Science.gov (United States)

    Ou-Yang, Mang; Hsieh, Yao-Fang; Lee, Cheng-Chung

    Cytopathological examination through biopsy is very important for carcinoma detection. The embedded relay lens microscopic hyperspectral imaging system (ERL-MHIS) provides a morphological image of a biopsy sample and the spectrum of each pixel in the image simultaneously. Based on the ERL-MHIS, this work develops morphological and spectral methods to diagnose oral carcinoma biopsy. In morphological discrimination, the fractal dimension method is applied to differentiate between normal and abnormal tissues. In spectral identification, normal and cancerous cells are distinguished using five methods. However, the spectra of normal and cancerous cells vary with patient. The diagnostic performances of the five methods are thus not ideal. Hence, the proposed cocktail approach is used to determine the effectiveness of the spectral methods in correlating with the sampling conditions. And then we use a combination of effective spectral methods according to the sample conditions for diagnosing a sample. A total of 68 biopsies from 34 patients are analyzed using the ERL-MHIS. The results demonstrate a sensitivity of 90 ± 4.53 % and a specificity of 87.8 ± 5.21 %. Furthermore, in our survey, this system is the first time utilized to study oral carcinoma biopsies.

  13. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  14. A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy

    Science.gov (United States)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2014-01-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm. PMID:25076821

  15. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Docktor, B.J.L.; MacGregor, J.H.; Burrowes, P.W. [Foothills Medical Centre, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)]. E-mail: bobbie.docktor@calgaryhealthregion.ca

    2004-06-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram. (author)

  16. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy.

    Science.gov (United States)

    Docktor, Bobbie Jo L; MacGregor, John Henry; Burrowes, Paul W

    2004-06-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram.

  17. Ultrasonographic findings 6 months after 11-gauge vacuum-assisted large-core breast biopsy

    International Nuclear Information System (INIS)

    Docktor, B.J.L.; MacGregor, J.H.; Burrowes, P.W.

    2004-01-01

    To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram. (author)

  18. Evaluating low dose ionizing radiation effects on gene expression in human skin biopsy cores

    International Nuclear Information System (INIS)

    Goldberg, Z.; Schwietert, C.; Stern, R.L.; Lehnert, B.E.

    2003-01-01

    Significant biological effects can occur in animals, animal cells, immortalized human cell lines, and primary human cells after exposure to doses of ionizing radiation (IR) in the <1-10 cGy region. However it is unclear how these observations mimic or even pertain to the actual in vivo condition in humans, though such knowledge is required for reducing the uncertainty of assessing human risks due to low dose IR (LDIR) exposures. Further, low dose effects have increasing clinical relevance in the radiotherapeutic management of cancer as the volume of tissue receiving only LDIR increases as more targeted radiotherapy (i.e. IMRT) becomes more widely used. Thus, human translational data must be obtained with which to correlate in vitro experimental findings and evaluate their 'real-life' applicability. To evaluate LDIR effects in human tissue we have obtained freshly explanted full thickness human skin samples obtained from aesthetic surgery, and subjected them to ex vivo irradiation as a translational research model system of a complex human tissue. Ionizing radiation (IR) exposures were delivered at 1, 10, or 100 cGy. The temporal response to IR was assessed by harvesting RNA at multiple time points out to 24 hours post IR. Gene expression changes were assessed by real time PCR. We have shown that RNA can be reliably extracted with fidelity from 3 mm diameter punch biopsies of human tissue and provide good quality sample for the real time PCR evaluation. Genes of interest include those reported to have altered expression following LDIR from in vitro cell culture models. These include genes associated with cell cycle regulation, DNA repair and various cytokines. These feasibility studies in human skin irradiated ex vivo, have demonstrated that gene expression can be measured accurately from very small human tissue samples, thus setting the stage for biopsy acquisition of tissue irradiated in vivo from patients-volunteers. The clinical study has begun and the data from

  19. The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hye Kyoung [Dept. of Radiology, Yangji General Hospital, Kwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health College, Kwangju (Korea, Republic of)

    2008-06-15

    We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  20. The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound

    International Nuclear Information System (INIS)

    Kang, Hye Kyoung; Dong, Kyung Rae

    2008-01-01

    We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  1. Nucleic Acid Amplification Testing and Sequencing Combined with Acid-Fast Staining in Needle Biopsy Lung Tissues for the Diagnosis of Smear-Negative Pulmonary Tuberculosis.

    Directory of Open Access Journals (Sweden)

    Faming Jiang

    Full Text Available Smear-negative pulmonary tuberculosis (PTB is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB staining of needle biopsy lung tissues for patients with suspected smear-negative PTB.Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR. For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM. The sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination.Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124. Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB for the diagnosis of smear-negative were 61.7% (82/133, 100% (48/48, 100% (82/82, 48.5% (48/181, and 71.8% (130/181, respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133, 95.8% (46/48, 98.3% (119/121, and 76.7% (46/60, respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181] than histological acid-fast staining (71.8% [130/181], P < 0.001. Parallel testing of histological AFB staining and PCR showed the

  2. Validation of liquid biopsy: plasma cell-free DNA testing in clinical management of advanced non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Veldore VH

    2018-01-01

    Full Text Available Vidya H Veldore,1,* Anuradha Choughule,2,* Tejaswi Routhu,1 Nitin Mandloi,1 Vanita Noronha,2 Amit Joshi,2 Amit Dutt,3 Ravi Gupta,1 Ramprasad Vedam,1 Kumar Prabhash2 1MedGenome Labs Private Ltd,, Bangalore, India; 2Tata Memorial Centre, Parel, Mumbai, India; 3The Advanced Centre for Treatment, Research and Education in Cancer, Tata Memorial Center, Kharghar, Navi Mumbai, Maharashtra, India *These authors contributed equally to this work Abstract: Plasma cell-free tumor DNA, or circulating tumor DNA (ctDNA, from liquid biopsy is a potential source of tumor genetic material, in the absence of tissue biopsy, for EGFR testing. Our validation study reiterates the clinical utility of ctDNA next generation sequencing (NGS for EGFR mutation testing in non-small cell lung cancer (NSCLC. A total of 163 NSCLC cases were included in the validation, of which 132 patients had paired tissue biopsy and ctDNA. We chose to validate ctDNA using deep sequencing with custom designed bioinformatics methods that could detect somatic mutations at allele frequencies as low as 0.01%. Benchmarking allele specific real time PCR as one of the standard methods for tissue-based EGFR mutation testing, the ctDNA NGS test was validated on all the plasma derived cell-free DNA samples. We observed a high concordance (96.96% between tissue biopsy and ctDNA for oncogenic driver mutations in Exon 19 and Exon 21 of the EGFR gene. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the assay were 91.1%, 100% 100%, 95.6%, and 97%, respectively. A false negative rate of 3% was observed. A subset of mutations was also verified on droplet digital PCR. Sixteen percent EGFR mutation positivity was observed in patients where only liquid biopsy was available, thus creating options for targeted therapy. This is the first and largest study from India, demonstrating successful validation of circulating cell-free DNA as a clinically

  3. Enzyme immunoassay of oestrogen receptors in needle biopsies from human liver

    DEFF Research Database (Denmark)

    Becker, U; Andersen, J; Poulsen, H S

    1991-01-01

    For quantitative assessments of sex hormone receptors in liver tissue, ligand binding assays are inconvenient, as they require large biopsies (0.5-1.0 g). The present study shows that it is possible to measure oestrogen receptors (ER) quantitatively in needle biopsy specimens as small as 10 mg...... by modifications of a commercial enzyme immunoassay employing monoclonal antibodies. Sucrose gradient centrifugation and the dextran charcoal method served as reference methods. A consecutive series of needle biopsies from patients suspected of liver disease were investigated. The biopsies (n = 37) had a median...

  4. Improvised double-embedding technique of minute biopsies: a mega boon to histopathology laboratory.

    Science.gov (United States)

    Yadav, Lokendra; Thomas, Sarega; Kini, Usha

    2015-01-01

    Optimal orientation of minute mucosal biopsies is essential for a definite diagnosis in gastrointestinal pathology or to visualize neural plexuses in Hirschsprung disease. The problem of minute size of the biopsy and its orientation gets compounded when they are from neonates and mandates exhaustive strip cuts, thus delaying reporting. A modified agar-paraffin technique is aimed to make tissue embedding efficient and user-friendly by inking mapping biopsies (one or more) either fresh or fixed with surgical coloring inks followed by embedding first in agar after orientation and followed thereafter by processing, re-embedding in paraffin wax, sectioning and staining. The tissues in agar paraffin block were found to be well processed, firm, held secure and well preserved. The blocks were easy to cut, with serial sections of thickness 2-3 μ and easy to spread. The colored inks remained permanently on the tissues both in the block as well as on the sections which helped in easy identification of tissues. Agar did not interfere with any stain such as Hematoxylin and Eosin or with histochemical stains, enzyme histochemistry or immunohistochemistry. Inking biopsies and pooling them in a block when obtained from the same patient reduced the number of tissue blocks. The modified agar-paraffin embedding technique is a simple reliable user friendly method that can greatly improve the quality of diagnostic information from minute biopsies by optimal orientation, better quality of sections, faster turnaround time and cost-effectiveness by economizing on the number of paraffin blocks, manpower, chemical reagents and laboratory infrastructure.

  5. Improvised double-embedding technique of minute biopsies: A mega boon to histopathology laboratory

    Directory of Open Access Journals (Sweden)

    Lokendra Yadav

    2015-01-01

    Full Text Available Introduction: Optimal orientation of minute mucosal biopsies is essential for a definite diagnosis in gastrointestinal pathology or to visualize neural plexuses in Hirschsprung disease. The problem of minute size of the biopsy and its orientation gets compounded when they are from neonates and mandates exhaustive strip cuts, thus delaying reporting. Aim: A modified agar-paraffin technique is aimed to make tissue embedding efficient and user-friendly by inking mapping biopsies (one or more either fresh or fixed with surgical coloring inks followed by embedding first in agar after orientation and followed thereafter by processing, re-embedding in paraffin wax, sectioning and staining. Results: The tissues in agar paraffin block were found to be well processed, firm, held secure and well preserved. The blocks were easy to cut, with serial sections of thickness 2-3 μ and easy to spread. The colored inks remained permanently on the tissues both in the block as well as on the sections which helped in easy identification of tissues. Agar did not interfere with any stain such as Hematoxylin and Eosin or with histochemical stains, enzyme histochemistry or immunohistochemistry. Inking biopsies and pooling them in a block when obtained from the same patient reduced the number of tissue blocks. Conclusion: The modified agar-paraffin embedding technique is a simple reliable user friendly method that can greatly improve the quality of diagnostic information from minute biopsies by optimal orientation, better quality of sections, faster turnaround time and cost-effectiveness by economizing on the number of paraffin blocks, manpower, chemical reagents and laboratory infrastructure.

  6. [Quantity research on epidermal growth factor in saliva and epidermal growth factor receptor in biopsy samples of recurrent aphthous ulcer patients].

    Science.gov (United States)

    Gu, Yang; Zhang, Gang; Lin, Mei

    2008-02-01

    To examine the change of epidermal growth factor (EGF) concentration in saliva of recurrent aphthous ulcer (RAU) patients during the ulcerous and interval period and epidermal growth factor receptor (EGFR) in ulcer biopsy samples. ECF data of the samples, which were 27 saliva samples from RAU gained not only in the ulcerous period but also in interval period and 33 ones from normal persons, were acquired through enzyme linked immunosorhent assay (ELISA) and EGF standard curve. ECFR-RNA date of RAU biopsies, which were 31 biopsy samples from RAU got during the ulcerous period and 35 ones from normal persons, were surveyed by QF-RT-PCR. All RAU samples were obtained under the same level, which were the whole patients were minor aphthous ulcers and their ulcers occurred not over the first four days. All patients and normal persons were selected seriously under the rule of physical situations without any other diseases and histories of using medicines. The EGF concentration of saliva in RAU group at ulcer occurrence was higher than that in the interval period and the normal control with a significant test (F = 3.24, P ulcer occurrence was higher than the normal control with a significant test (t = 3.15, P ulcer occasion of RAU patients could be related with the decreasing of EGF in saliva during interval period, and that the ulcer sell-cure of RAU patients would be contributed to

  7. An unsupervised MVA method to compare specific regions in human breast tumor tissue samples using ToF-SIMS.

    Science.gov (United States)

    Bluestein, Blake M; Morrish, Fionnuala; Graham, Daniel J; Guenthoer, Jamie; Hockenbery, David; Porter, Peggy L; Gamble, Lara J

    2016-03-21

    Imaging time-of-flight secondary ion mass spectrometry (ToF-SIMS) and principal component analysis (PCA) were used to investigate two sets of pre- and post-chemotherapy human breast tumor tissue sections to characterize lipids associated with tumor metabolic flexibility and response to treatment. The micron spatial resolution imaging capability of ToF-SIMS provides a powerful approach to attain spatially-resolved molecular and cellular data from cancerous tissues not available with conventional imaging techniques. Three ca. 1 mm(2) areas per tissue section were analyzed by stitching together 200 μm × 200 μm raster area scans. A method to isolate and analyze specific tissue regions of interest by utilizing PCA of ToF-SIMS images is presented, which allowed separation of cellularized areas from stromal areas. These PCA-generated regions of interest were then used as masks to reconstruct representative spectra from specifically stromal or cellular regions. The advantage of this unsupervised selection method is a reduction in scatter in the spectral PCA results when compared to analyzing all tissue areas or analyzing areas highlighted by a pathologist. Utilizing this method, stromal and cellular regions of breast tissue biopsies taken pre- versus post-chemotherapy demonstrate chemical separation using negatively-charged ion species. In this sample set, the cellular regions were predominantly all cancer cells. Fatty acids (i.e. palmitic, oleic, and stearic), monoacylglycerols, diacylglycerols and vitamin E profiles were distinctively different between the pre- and post-therapy tissues. These results validate a new unsupervised method to isolate and interpret biochemically distinct regions in cancer tissues using imaging ToF-SIMS data. In addition, the method developed here can provide a framework to compare a variety of tissue samples using imaging ToF-SIMS, especially where there is section-to-section variability that makes it difficult to use a serial hematoxylin

  8. Biopsy case mix and diagnostic yield at a Malawian central hospital ...

    African Journals Online (AJOL)

    Pathological examination of tissue biopsies with histological confirmation of a correct cancer diagnosis is central to cancer care. Without an accurate and specific ... The oesophagus was the most common biopsied site followed by breast, bladder, bone, prostate, bowel, and cervical lymph node. Malignancies were found in ...

  9. Transbronchial lung biopsy without fluoroscopic guide in Tehran Imam Khomeini’s Hospital (1999

    Directory of Open Access Journals (Sweden)

    "Firoozbakhsh S

    2002-08-01

    Full Text Available Background: Transbronchial lung biopsy (TBLB is an attractive alternative to open lung biopsy as an initial diagnostic procedure for patients with diffuse parenchymal disease or localized densities beyond direct endoscopic vision. TBLB can be carried out safely without fluoroscopy in patients with diffuse lung disease. Since in our bronchoscopic department fluoroscopy is not available, we planned to evaluate the blind (without fluoroscopic guide TBLB being performed in our department to determine the success rate in obtaining lung tissue, the sensitivity of the procedure and the risk of complications. Materials and Methods: Sixty-Four TBLB were done in our department during a 6 month period (March-September 1999. Results: Lung tissue wasn’t detected in two (3.1 percent samples. Pathological results were helpful in 46 (71.9 percent cases. No evidence of hemoptysis was found after the procedure. Three (4.68 percent cases of pneumothorax was detected. Only one of them required chest tube (1.51 percent. Conclusion: We concluded that blind TBLB was successful in our department with rates of complications comparable to other approved centers.

  10. Soft Tissue Sarcoma

    Science.gov (United States)

    ... muscles, tendons, fat, and blood vessels. Soft tissue sarcoma is a cancer of these soft tissues. There ... have certain genetic diseases. Doctors diagnose soft tissue sarcomas with a biopsy. Treatments include surgery to remove ...

  11. Wavelet data processing of micro-Raman spectra of biological samples

    Science.gov (United States)

    Camerlingo, C.; Zenone, F.; Gaeta, G. M.; Riccio, R.; Lepore, M.

    2006-02-01

    A wavelet multi-component decomposition algorithm is proposed for processing data from micro-Raman spectroscopy (μ-RS) of biological tissue. The μ-RS has been recently recognized as a promising tool for the biopsy test and in vivo diagnosis of degenerative human tissue pathologies, due to the high chemical and structural information contents of this spectroscopic technique. However, measurements of biological tissues are usually hampered by typically low-level signals and by the presence of noise and background components caused by light diffusion or fluorescence processes. In order to overcome these problems, a numerical method based on discrete wavelet transform is used for the analysis of data from μ-RS measurements performed in vitro on animal (pig and chicken) tissue samples and, in a preliminary form, on human skin and oral tissue biopsy from normal subjects. Visible light μ-RS was performed using a He-Ne laser and a monochromator with a liquid nitrogen cooled charge coupled device equipped with a grating of 1800 grooves mm-1. The validity of the proposed data procedure has been tested on the well-characterized Raman spectra of reference acetylsalicylic acid samples.

  12. Translational Research in Pediatrics IV: Solid Tissue Collection and Processing.

    Science.gov (United States)

    Gillio-Meina, Carolina; Zielke, H Ronald; Fraser, Douglas D

    2016-01-01

    Solid tissues are critical for child-health research. Specimens are commonly obtained at the time of biopsy/surgery or postmortem. Research tissues can also be obtained at the time of organ retrieval for donation or from tissue that would otherwise have been discarded. Navigating the ethics of solid tissue collection from children is challenging, and optimal handling practices are imperative to maximize tissue quality. Fresh biopsy/surgical specimens can be affected by a variety of factors, including age, gender, BMI, relative humidity, freeze/thaw steps, and tissue fixation solutions. Postmortem tissues are also vulnerable to agonal factors, body storage temperature, and postmortem intervals. Nonoptimal tissue handling practices result in nucleotide degradation, decreased protein stability, artificial posttranslational protein modifications, and altered lipid concentrations. Tissue pH and tryptophan levels are 2 methods to judge the quality of solid tissue collected for research purposes; however, the RNA integrity number, together with analyses of housekeeping genes, is the new standard. A comprehensive clinical data set accompanying all tissue samples is imperative. In this review, we examined: the ethical standards relating to solid tissue procurement from children; potential sources of solid tissues; optimal practices for solid tissue processing, handling, and storage; and reliable markers of solid tissue quality. Copyright © 2016 by the American Academy of Pediatrics.

  13. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  14. Fit for purpose frozen tissue collections by RNA integrity number-based quality control assurance at the Erasmus MC tissue bank.

    Science.gov (United States)

    Kap, Marcel; Oomen, Monique; Arshad, Shazia; de Jong, Bas; Riegman, Peter

    2014-04-01

    About 5000 frozen tissue samples are collected each year by the Erasmus Medical Center tissue bank. Two percent of these samples are randomly selected annually for RNA isolation and RNA Integrity Number (RIN) measurement. A similar quality assessment was conducted during centralization of a 20-year-old tissue collection from the cancer institute, a 15-year-old liver sample archive (-80°C), and a 13-year-old clinical pathology frozen biopsy archive (Liquid Nitrogen). Samples were divided into either high-quality (RIN ≥6.5) or low-quality overall categories, or into four "fit-for-purpose" quality groups: RIN procurement protocols used for these samples needed immediate evaluation. When the distribution of RIN values of the different collections were compared, no significant differences were found, despite differences in average storage time and temperature. According to the principle of "fit-for-purpose" distribution, the vast majority of samples are considered good enough for most downstream techniques. In conclusion, an annual tissue bank quality control procedure provides useful information on tissue sample quality and sheds light on where and if improvements need to be made.

  15. Importance of tissue biopsy in suicidal hanging deaths

    Directory of Open Access Journals (Sweden)

    Manal S. Bamousa

    2015-12-01

    The total number of cases was 62; 85.5% of the deceased were males, while 15% were females. The majority of cases (53% were among the age group of 20–30 years. Hemorrhage of the sternocleidomastoid muscle and carotid intimal tear were both found in 90% of cases. Thyroid congestion was detected in 91%, and Hashimoto’s thyroiditis was diagnosed in 2% of studied cases. The study discusses the importance of biopsy examination in hanging deaths and compares its results with other similar previous studies.

  16. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  17. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Directory of Open Access Journals (Sweden)

    Zavislan James M

    2009-08-01

    Full Text Available Abstract Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS, 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and

  18. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Science.gov (United States)

    2009-01-01

    Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM) is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS) as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS), 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and infiltrating carcinoma, and

  19. A novel technique for diaphragm biopsies in human patients.

    Science.gov (United States)

    Noullet, Séverine; Romero, Norma; Menegaux, Fabrice; Chapart, Maud; Demoule, Alexandre; Morelot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jésus

    2015-06-15

    The diaphragm is difficult to biopsy because of its anatomic location. We describe a new laparoscopic diaphragm biopsy technique. Fifty one patients with amyotrophic lateral sclerosis gave their consent to diaphragm biopsy in the context of an implanted phrenic nerve stimulation protocol (NCT01583088). The biopsy was taken from the costal diaphragm, after opening the parietal peritoneum with scissors, and by grasping the diaphragmatic muscle over the rib with toothed laparoscopy forceps. The first four electrocoagulation biopsies were unsuitable for morphologic examination. The following 47 biopsies were therefore performed without electrocoagulation. The mean size of the biopsy fragments obtained after preparation was 3 ± 1 × 2 ± 1 × 1 ± 1 mm (maximum: 4 × 3 × 2 mm). A diaphragmatic injury occurred during the section in three cases requiring immediate suture without causing pneumothorax. A small pleural effusion was observed on the postoperative chest x-ray in one patient with a spontaneously favorable outcome. Numerous stains were able to be performed on the fragments obtained. Diaphragm biopsy can be safely performed by laparoscopy and yields tissue suitable for our future histologic evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Antiendomysial and antihuman recombinant tissue transglutaminase antibodies in the diagnosis of coeliac disease: a biopsy-proven European multicentre study.

    Science.gov (United States)

    Collin, Pekka; Kaukinen, Katri; Vogelsang, Harald; Korponay-Szabó, Ilma; Sommer, Rudolf; Schreier, Elisabeth; Volta, Umberto; Granito, Alessandro; Veronesi, Lorenza; Mascart, Françoise; Ocmant, Annick; Ivarsson, Anneli; Lagerqvist, Carina; Bürgin-Wolff, Annemarie; Hadziselimovic, Faruk; Furlano, Raoul I; Sidler, Marc A; Mulder, Chris J J; Goerres, Marije S; Mearin, M Luisa; Ninaber, Maarten K; Gudmand-Høyer, Eivind; Fabiani, Elisabetta; Catassi, Carlo; Tidlund, Helena; Alainentalo, Lisbeth; Mäki, Markku

    2005-01-01

    To investigate the value of serum antitissue transglutaminase IgA antibodies (IgA-TTG) and IgA antiendomysial antibodies (IgA-EMA) in the diagnosis of coeliac disease in cohorts from different geographical areas in Europe. The setting allowed a further comparison between the antibody results and the conventional small-intestinal histology. A total of 144 cases with coeliac disease [median age 19.5 years (range 0.9-81.4)], and 127 disease controls [median age 29.2 years (range 0.5-79.0)], were recruited, on the basis of biopsy, from 13 centres in nine countries. All biopsy specimens were re-evaluated and classified blindly a second time by two investigators. IgA-TTG were determined by ELISA with human recombinant antigen and IgA-EMA by an immunofluorescence test with human umbilical cord as antigen. The quality of the biopsy specimens was not acceptable in 29 (10.7%) of 271 cases and a reliable judgement could not be made, mainly due to poor orientation of the samples. The primary clinical diagnosis and the second classification of the biopsy specimens were divergent in nine cases, and one patient was initially enrolled in the wrong group. Thus, 126 coeliac patients and 106 controls, verified by biopsy, remained for final analysis. The sensitivity of IgA-TTG was 94% and IgA-EMA 89%, the specificity was 99% and 98%, respectively. Serum IgA-TTG measurement is effective and at least as good as IgA-EMA in the identification of coeliac disease. Due to a high percentage of poor histological specimens, the diagnosis of coeliac disease should not depend only on biopsy, but in addition the clinical picture and serology should be considered.

  1. [Musculoskeletal biopsies in an open 0.5-T-MR system].

    Science.gov (United States)

    Pretzsch, M; Scholz, R; Moche, M; Thomas, M; Tannapfel, A; von Salis-Soglio, G

    2005-01-01

    MR-guided interventions have been successful in different medical disciplines. The aim of this paper is to report our results with the application of MR-guided biopsies of musculoskeletal lesions using an open 0.5-T-MR scanner and further to discuss these results on the basis of the available literature. Between 1998 and 2003 30 patients (average age 44.1 years) underwent a total of 31 biopsies. The interventions were performed in an open 0.5-T MRI system using an active optical localization system as well as a navigation system. For the motion tracking we used T (1)-weighted real-time sequences with 0.25 pictures per second. For the sampling MR-compatible instruments were used that were specially developed for this purpose. The data of this retrospective investigation are based on the evaluation of the patient documents and the radiological findings. On the basis of the histological findings the technical success rate and the histological overall accuracy were determined. In 81 % of the biopsies the histological diagnosis was correct. In cases of suspected inflammation the histological accuracy was smaller (70 %). No differences were observed between skeletal and soft-tissue lesions. The technical success rate amounted to 77.5 %. No procedural or anesthesiological complications occurred. The mean operating time amounted to 65 min including the time for motion tracking. In cases of suspected lesions of the musculoskeletal system, the MR-guided biopsy represents a promising and safe procedure to get a histological diagnosis. In cases of sufficient size of the lesion sampling of a representative probe is possible. On account of the outstanding performance in soft-part contrasting, the sensitive structures surrounding the lesion can be saved. Substantial disadvantages of the procedure are the high costs for personal and material and the long operating time.

  2. A novel technique of serial biopsy in mouse brain tumour models.

    Directory of Open Access Journals (Sweden)

    Sasha Rogers

    Full Text Available Biopsy is often used to investigate brain tumour-specific abnormalities so that treatments can be appropriately tailored. Dacomitinib (PF-00299804 is a tyrosine kinase inhibitor (TKI, which is predicted to only be effective in cancers where the targets of this drug (EGFR, ERBB2, ERBB4 are abnormally active. Here we describe a method by which serial biopsy can be used to validate response to dacomitinib treatment in vivo using a mouse glioblastoma model. In order to determine the feasibility of conducting serial brain biopsies in mouse models with minimal morbidity, and if successful, investigate whether this can facilitate evaluation of chemotherapeutic response, an orthotopic model of glioblastoma was used. Immunodeficient mice received cortical implants of the human glioblastoma cell line, U87MG, modified to express the constitutively-active EGFR mutant, EGFRvIII, GFP and luciferase. Tumour growth was monitored using bioluminescence imaging. Upon attainment of a moderate tumour size, free-hand biopsy was performed on a subgroup of animals. Animal monitoring using a neurological severity score (NSS showed that all mice survived the procedure with minimal perioperative morbidity and recovered to similar levels as controls over a period of five days. The technique was used to evaluate dacomitinib-mediated inhibition of EGFRvIII two hours after drug administration. We show that serial tissue samples can be obtained, that the samples retain histological features of the tumour, and are of sufficient quality to determine response to treatment. This approach represents a significant advance in murine brain surgery that may be applicable to other brain tumour models. Importantly, the methodology has the potential to accelerate the preclinical in vivo drug screening process.

  3. Transrectal ultrasound: Diagnosis of prostate cancer by a new biplane US-guided biopsy technique. Comparison of thin-needle cytology and histology with large-core biopsy

    International Nuclear Information System (INIS)

    Lee, F.; Littrup, P.; McLeary, R.; Kumasaka, G.; Borlaza, G.; McHugh, T.; Soiderer, M.; Roi, L.

    1986-01-01

    A new transperineal biopsy technique was developed that uses biplane transrectal US guidance for needle placement into anechoic-hypoechoic lesions thought to indicate prostate cancer (n = 83). The results of histologic studies on biopsy material obtained with a 22-gauge needle and of aspiration histologic studies on biopsy material obtained with a 19-gauge needle were compared with results of histologic studies on material obtained with a 14-gauge needle. When sufficient tissue was obtained, the positive biopsy yield was 61% by cytology and 58% by histology; the combined yield was 61%. A limited study ( n = 21) of histologic findings in biopsy material obtained with 19-gauge and 14-gauge needles showed equivalent diagnostic results. Sixty-seven percent of the biopsies were of lesions less than 1.5 cm in diameter, and 57% (13 of 23) of the biopsy-proved cancers in this group were either nonpalpable or only mildly suspicious on digital rectal examination

  4. Differentiating cancerous from normal breast tissue by redox imaging

    Science.gov (United States)

    Xu, He N.; Tchou, Julia; Feng, Min; Zhao, Huaqing; Li, Lin Z.

    2015-02-01

    Abnormal metabolism can be a hallmark of cancer occurring early before detectable histological changes and may serve as an early detection biomarker. The current gold standard to establish breast cancer (BC) diagnosis is histological examination of biopsy. Previously we have found that pre-cancer and cancer tissues in animal models displayed abnormal mitochondrial redox state. Our technique of quantitatively measuring the mitochondrial redox state has the potential to be implemented as an early detection tool for cancer and may provide prognostic value. We therefore in this present study, investigated the feasibility of quantifying the redox state of tumor samples from 16 BC patients. Tumor tissue aliquots were collected from both normal and cancerous tissue from the affected cancer-bearing breasts of 16 female patients (5 TNBC, 9 ER+, 2 ER+/Her2+) shortly after surgical resection. All specimens were snap-frozen with liquid nitrogen on site and scanned later with the Chance redox scanner, i.e., the 3D cryogenic NADH/oxidized flavoprotein (Fp) fluorescence imager. Our preliminary results showed that both NADH and Fp (including FAD, i.e., flavin adenine dinucleotide) signals in the cancerous tissues roughly tripled to quadrupled those in the normal tissues (pcancerous tissues than in the normal ones (pcancer and non-cancer breast tissues in human patients and this novel redox scanning procedure may assist in tissue diagnosis in freshly procured biopsy samples prior to tissue fixation. We are in the process of evaluating the prognostic value of the redox imaging indices for BC.

  5. Probing Endogenous Collagen by Laser Induced Autofluorescence in Burn Wound Biopsies- A Pilot Study.

    Science.gov (United States)

    Prabhu, Vijendra; Acharya, Anusha; Rao, Bola Sadashiva Satish; Rathnakar, Bharath; Kumar, Pramod; Guddattu, Vasudeva; Mahato, Krishna Kishore

    2018-04-19

    The focus of the current study was to interrogate the predictive potential of laser-induced autofluorescence (LIAF) by objectively assessing collagen synthesis in burn wound granulation tissues ex vivo. Prior grafting, granulation tissues (20 samples) following burn injury were collected from 17 subjects of age range 18- 60 years with patient/donor consent and the corresponding autofluorescence spectra were recorded at 325 nm He-Cd laser (≈ 2 mW) excitations. The resulting endogenous collagen intensity from the above tissue samples was computed by normalizing the NADH levels. In addition, the hydroxyproline content was also estimated biochemically from the same granulation tissues. A comparative assessment of both LIAF and biochemical estimations for endogenous collagen by hydroxyproline resulted in strong positive correlation among them. The above relevant observations suggest that LIAF is equally informative as that of biochemical estimations, in evaluating endogenous collagen content in wound granulation tissues. Thus, it can be concluded that LIAF has the predictive potential, as a non-invasive objective tool to measure the endogenous collagen levels in wound biopsy tissues and provide complementary data conducive for making clinical decisions. This article is protected by copyright. All rights reserved.

  6. Technical note: Alternatives to reduce adipose tissue sampling bias.

    Science.gov (United States)

    Cruz, G D; Wang, Y; Fadel, J G

    2014-10-01

    Understanding the mechanisms by which nutritional and pharmaceutical factors can manipulate adipose tissue growth and development in production animals has direct and indirect effects in the profitability of an enterprise. Adipocyte cellularity (number and size) is a key biological response that is commonly measured in animal science research. The variability and sampling of adipocyte cellularity within a muscle has been addressed in previous studies, but no attempt to critically investigate these issues has been proposed in the literature. The present study evaluated 2 sampling techniques (random and systematic) in an attempt to minimize sampling bias and to determine the minimum number of samples from 1 to 15 needed to represent the overall adipose tissue in the muscle. Both sampling procedures were applied on adipose tissue samples dissected from 30 longissimus muscles from cattle finished either on grass or grain. Briefly, adipose tissue samples were fixed with osmium tetroxide, and size and number of adipocytes were determined by a Coulter Counter. These results were then fit in a finite mixture model to obtain distribution parameters of each sample. To evaluate the benefits of increasing number of samples and the advantage of the new sampling technique, the concept of acceptance ratio was used; simply stated, the higher the acceptance ratio, the better the representation of the overall population. As expected, a great improvement on the estimation of the overall adipocyte cellularity parameters was observed using both sampling techniques when sample size number increased from 1 to 15 samples, considering both techniques' acceptance ratio increased from approximately 3 to 25%. When comparing sampling techniques, the systematic procedure slightly improved parameters estimation. The results suggest that more detailed research using other sampling techniques may provide better estimates for minimum sampling.

  7. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  8. 6. Label-free selective plane illumination microscopy of tissue samples

    Directory of Open Access Journals (Sweden)

    Muteb Alharbi

    2017-10-01

    Conclusion: Overall this method meets the demands of the current needs for 3D imaging tissue samples in a label-free manner. Label-free Selective Plane Microscopy directly provides excellent information about the structure of the tissue samples. This work has highlighted the superiority of Label-free Selective Plane Microscopy to current approaches to label-free 3D imaging of tissue.

  9. Utilization of Cell-Transfer Technique for Molecular Testing on Hematoxylin-Eosin-Stained Sections: A Viable Option for Small Biopsies That Lack Tumor Tissues in Paraffin Block.

    Science.gov (United States)

    Wu, Howard H; Jovonovich, Stephen M; Randolph, Melissa; Post, Kristin M; Sen, Joyashree D; Curless, Kendra; Cheng, Liang

    2016-12-01

    - In some instances the standard method of doing molecular testing from formalin-fixed, paraffin-embedded block is not possible because of limited tissue. Tumor cell-enriched cell-transfer technique has been proven useful for performing immunocytochemistry and molecular testing on cytologic smears. - To establish the cell-transfer technique as a viable option for isolating tumor cells from hematoxylin-eosin (H&E)-stained slides. - Molecular testing was performed by using the cell-transfer technique on 97 archived H&E-stained slides from a variety of different tumors. Results were compared to the conventional method of molecular testing. - Polymerase chain reaction-based molecular testing via the cell-transfer technique was successfully performed on 82 of 97 samples (85%). This included 39 of 47 cases for EGFR, 10 of 11 cases for BRAF, and 33 of 39 cases for KRAS mutations. Eighty-one of 82 cell-transfer technique samples (99%) showed agreement with previous standard method results, including 4 mutations and 35 wild-type alleles for EGFR, 4 mutations and 6 wild-type alleles for BRAF, and 11 mutations and 21 wild-type alleles for KRAS. There was only 1 discrepancy: a cell-transfer technique with a false-negative >KRAS result (wild type versus G12C). - Molecular testing performed on H&E-stained sections via cell-transfer technique is useful when tissue from cell blocks and small surgical biopsy samples is exhausted and the only available material for testing is on H&E-stained slides.

  10. Persistent organic pollutants and stable isotopes in biopsy samples (2004/2006) from Southern Resident killer whales

    International Nuclear Information System (INIS)

    Krahn, Margaret M.; Hanson, M. Bradley; Baird, Robin W.; Boyer, Richard H.; Burrows, Douglas G.; Emmons, Candice K.; Ford, John K.B.; Jones, Linda L.; Noren, Dawn P.; Ross, Peter S.; Schorr, Gregory S.; Collier, Tracy K.

    2007-01-01

    'Southern Resident' killer whales include three 'pods' (J, K and L) that reside primarily in Puget Sound/Georgia Basin during the spring, summer and fall. This population was listed as 'endangered' in the US and Canada following a 20% decline between 1996 and 2001. The current study, using blubber/epidermis biopsy samples, contributes contemporary information about potential factors (i.e., levels of pollutants or changes in diet) that could adversely affect Southern Residents. Carbon and nitrogen stable isotopes indicated J- and L-pod consumed prey from similar trophic levels in 2004/2006 and also showed no evidence for a large shift in the trophic level of prey consumed by L-pod between 1996 and 2004/2006. ΣPCBs decreased for Southern Residents biopsied in 2004/2006 compared to 1993-1995. Surprisingly, however, a three-year-old male whale (J39) had the highest concentrations of ΣPBDEs, ΣHCHs and HCB. POP ratio differences between J- and L-pod suggested that they occupy different ranges in winter

  11. Synovial tissue research

    DEFF Research Database (Denmark)

    Orr, Carl; Sousa, Elsa; Boyle, David L

    2017-01-01

    The synovium is the major target tissue of inflammatory arthritides such as rheumatoid arthritis. The study of synovial tissue has advanced considerably throughout the past few decades from arthroplasty and blind needle biopsy to the use of arthroscopic and ultrasonographic technologies that enable...... easier visualization and improve the reliability of synovial biopsies. Rapid progress has been made in using synovial tissue to study disease pathogenesis, to stratify patients, to discover biomarkers and novel targets, and to validate therapies, and this progress has been facilitated by increasingly...... diverse and sophisticated analytical and technological approaches. In this Review, we describe these approaches, and summarize how their use in synovial tissue research has improved our understanding of rheumatoid arthritis and identified candidate biomarkers that could be used in disease diagnosis...

  12. Success and failure rates of tumor genotyping techniques in routine pathological samples with non-small-cell lung cancer.

    Science.gov (United States)

    Vanderlaan, Paul A; Yamaguchi, Norihiro; Folch, Erik; Boucher, David H; Kent, Michael S; Gangadharan, Sidharta P; Majid, Adnan; Goldstein, Michael A; Huberman, Mark S; Kocher, Olivier N; Costa, Daniel B

    2014-04-01

    Identification of some somatic molecular alterations in non-small-cell lung cancer (NSCLC) has become evidence-based practice. The success and failure rate of using commercially available tumor genotyping techniques in routine day-to-day NSCLC pathology samples is not well described. We sought to evaluate the success and failure rate of EGFR mutation, KRAS mutation, and ALK FISH in a cohort of lung cancers subjected to routine clinical tumor genotype. Clinicopathologic data, tumor genotype success and failure rates were retrospectively compiled and analyzed from 381 patient-tumor samples. From these 381 patients with lung cancer, the mean age was 65 years, 61.2% were women, 75.9% were white, 27.8% were never smokers, 73.8% had advanced NSCLC and 86.1% had adenocarcinoma histology. The tumor tissue was obtained from surgical specimens in 48.8%, core needle biopsies in 17.9%, and as cell blocks from aspirates or fluid in 33.3% of cases. Anatomic sites for tissue collection included lung (49.3%), lymph nodes (22.3%), pleura (11.8%), bone (6.0%), brain (6.0%), among others. The overall success rate for EGFR mutation analysis was 94.2%, for KRAS mutation 91.6% and for ALK FISH 91.6%. The highest failure rates were observed when the tissue was obtained from image-guided percutaneous transthoracic core-needle biopsies (31.8%, 27.3%, and 35.3% for EGFR, KRAS, and ALK tests, respectively) and bone specimens (23.1%, 15.4%, and 23.1%, respectively). In specimens obtained from bone, the failure rates were significantly higher for biopsies than resection specimens (40% vs. 0%, p=0.024 for EGFR) and for decalcified compared to non-decalcified samples (60% vs. 5.5%, p=0.021 for EGFR). Tumor genotype techniques are feasible in most samples, outside small image-guided percutaneous transthoracic core-needle biopsies and bone samples from core biopsies with decalcification, and therefore expansion of routine tumor genotype into the care of patients with NSCLC may not require special

  13. Liver biopsy — the current view?

    African Journals Online (AJOL)

    needles, or the more recent cutting-core automated or semi-automated needles. These may be single units, or part of gun-type system with disposable needles. The pathologist's requirements of the specimen depend on whether diffuse disease or focal lesions are biopsied. The ideal tissue core for diffuse disease should be ...

  14. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  15. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    Science.gov (United States)

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Short Communication: Immunohistochemical localization of the immune cell marker CD68 in bovine adipose tissue: impact of tissue alterations and excessive fat accumulation in dairy cows.

    Science.gov (United States)

    Häussler, S; Germeroth, D; Laubenthal, L; Ruda, L F; Rehage, J; Dänicke, S; Sauerwein, H

    2017-01-01

    With the onset of lactation energy from feed intake is mostly insufficient to meet the requirements of dairy cows. Lipid mobilization from adipose tissue (AT) could lead to a compromised inflammatory response enhancing the incidence for diseases. In addition, tissue alterations can occur, displaying areas of necrosis and inflammation. Furthermore, over-conditioned cows mobilizing more lipids from AT than thin cows are prone to develop metabolic disorders. This might lead to an increased infiltration of phagocytic immune cells into AT. In the present study, CD68 positive cells were localized in AT from 10 early lactating Holstein cows displaying different grades of AT alterations. Biopsies were sampled from visceral and subcutaneous AT and the number of CD68 positive cells was immunohistochemically determined. In addition, AT biopsies from over-conditioned, non-pregnant, non-lactating cows (n=8) were immunohistochemically analyzed for CD68 positive cells. The percentage of CD68 positive cells was less than 2% in AT biopsies with tissue alterations and in AT from over-conditioned cows. Therefore, immune cell infiltration demonstrated via the localization of CD68 positive cells seems to play only a minor role in AT from over-conditioned cows as well as in different bovine AT depots with tissue alterations. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Optimal Order of Successive Office Hysteroscopy and Endometrial Biopsy for the Evaluation of Abnormal Uterine Bleeding: A Randomized Controlled Trial.

    Science.gov (United States)

    Sarkar, Papri; Mikhail, Emad; Schickler, Robyn; Plosker, Shayne; Imudia, Anthony N

    2017-09-01

    To estimate the optimal order of office hysteroscopy and endometrial biopsy when performed successively for evaluation of abnormal uterine bleeding. Patients undergoing successive office hysteroscopy and endometrial biopsy were included in a single-blind, prospective, randomized trial. The primary outcome was to evaluate the effect of order of procedures on patients' pain score. Prespecified secondary outcomes include procedure duration, hysteroscopic visualization of the uterine cavity, endometrial sample adequacy, and number of attempts at biopsy. Pain scores were assessed using a visual analog scale from 0 to 10 and endometrial sample adequacy was determined from the histopathology report. Hysteroscopy images were recorded. Sample size of 34 per group (n=68) was determined to be adequate to detect a difference of 20% in visual analog scale score between hysteroscopy first (group A) and biopsy first (group B) at α of 0.05 and 80% power. Between October 2015 and January 2017, 78 women were randomized to group A (n=40) and group B (n=38). There was no difference in global pain perception [7 (0-10) vs 7 (0-10); P=.57, 95% CI 5.8-7.1]. Procedure duration [3 (1-9) vs 3 (2-10), P=.32, 95% CI 3.3-4.1] and endometrial sample adequacy (78.9% vs 75.7%, P=.74) were similar in both groups. Group A patients had better endometrial visualization (Pabnormal uterine bleeding, the global pain perception, and time required are independent of the order in which procedures are performed. Performing hysteroscopy first ensures better image, whereas biopsy first yields adequate tissue sample with fewer attempts. ClinicalTrials.gov, NCT02472184.

  18. Deep wound cultures correlate well with bone biopsy culture in diabetic foot osteomyelitis.

    Science.gov (United States)

    Malone, M; Bowling, F L; Gannass, A; Jude, E B; Boulton, A J M

    2013-10-01

    Osteomyelitis is a major complication in patients with diabetic foot ulceration. Accurate pathogenic identification of organisms can aid the clinician to a specific antibiotic therapy thereby preventing the need for amputation. All diabetic patients with bone biopsy-confirmed osteomyelitis were included into the study: biopsies were performed either during surgical removal of infected bone or percutaneously under guided fluoroscopy through non-infected tissue. The depth and extent of the ulcer was assessed using a sterile blunt metal probe. Deep wound cultures were taken from the wound base after sharp debridement. Of 66 cases of suspected osteomyelitis in 102 joints, 34 patients had both bone biopsies and deep wound cultures over the study period. Thirty two of 34 (94%), had a history of preceding foot ulceration, and in 25 of the cases a positive probe to bone test was recorded. In a high proportion of patients, at least one similar organism was isolated from both the deep wound culture and bone biopsy procedures (25 of 34 cases, 73.5%, p<0.001). When organisms were isolated from both wound cultures and bone biopsies, the identical strain was identified in both procedures in a significant proportion of cases (16 of 25 cases, 64%, p<0.001, total sample analysis in 16 of 34 cases, 47%). Deep wound cultures correlate well with osseous cultures and provide a sensitive method in assessing and targeting likely pathogens that cause osseous infections. This will help aid the clinician in guiding antibiotic therapy in centers where bone biopsies may not be readily available. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Endoscopic versus stereotactic procedure for pineal tumour biopsies: Comparative review of the literature and learning from a 25-year experience.

    Science.gov (United States)

    Balossier, A; Blond, S; Touzet, G; Lefranc, M; de Saint-Denis, T; Maurage, C-A; Reyns, N

    2015-01-01

    Pineal tumours account for 1% to 4% of brain tumours in adults and for around 10% in children. Except in a few cases where germ cell markers are elevated, accurate histological samples are mandatory to initiate the treatment. Open surgery still has a high morbidity and is often needless. Biopsies can either be obtained by endoscopic or stereotactic procedures. Following an extensive review of the literature (PubMed 1970-2013; keywords pineal tumour, biopsy; English and French), 33 studies were analysed and relevant data compared regarding the type of procedure, diagnosis rate, cerebrospinal fluid diversion type and rate, perioperative mortality, morbidity. Endoscopic and stereotactic biopsies showed a diagnosis rate of 81.1% (20%-100%) and 93.7% (82%-100%), respectively. Endoscopic biopsies involved 21.0% of minor and 2.0% of major complications whereas stereotactic biopsies involved 6.4% of minor and 1.6% of major complications. The most frequently reported complication was haemorrhage for both endoscopic and stereotactic procedures, accounting for 4.8% and 4.3%, respectively. Mortality rate was low for both endoscopic and stereotactic procedures, equal to 0.4% and 1.3%, respectively. Local experience of stereotactic biopsies was also reported and corroborated the previous data. The difference between both procedures is not statistically significant (p>0.05) across large series (≥20patients). Nevertheless, tissue diagnosis appears less accurate with endoscopic procedures than with stereotactic procedures (81.1% versus 93.7%, weighted mean across all series). In our opinion, the neuroendoscopic approach is the best tool for managing hydrocephalus, whereas stereotactic biopsies remain the best way to obtain a tissue diagnosis with accuracy and low morbidity. Copyright © 2014. Published by Elsevier Masson SAS.

  20. Detection of Xenotropic Murine Leukemia Virus-Related Virus in Prostate Biopsy Samples

    International Nuclear Information System (INIS)

    Baig, F. A.; Mirza, T.; Khanani, R.; Khan, S.

    2014-01-01

    Objective: To determine the association of Xenotropic murine leukemia virus related virus (XMRV) infection with prostate cancer and compare it with benign prostate hyperplasia. Study Design: Case control study. Place and Duration of Study: Department of Histopathology and Molecular Pathology, Dow University of Health Sciences, Karachi, from January 2009 to December 2012. Methodology: XMRV was screened in 50 prostate cancer and 50 benign prostatic hyperplasia biopsies using conventional end-point PCR. Other studied variables were family history of prostate cancer, patients age and Gleason score. Results: XMRV was detected in 4 (8%) of the 50 prostate cancer biopsy specimens compared to none in biopsies with benign prostatic hyperplasia. However, there was no significant statistical association of XMRV infection with the other variables. Conclusion: A low frequency of XMRV infection was found in this case-control study. Men, who harbor XMRV infection, may be at increased risk of prostate cancer but this needs to be investigated further at a larger scale. (author)

  1. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  2. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  3. A biomedical engineering approach to mitigate the errors of prostate biopsy.

    Science.gov (United States)

    Ahmed, Hashim Uddin; Emberton, Mark; Kepner, Gordon; Kepner, Jeremy

    2012-02-07

    The current protocol for detecting and ruling out prostate cancer involves serum PSA testing followed by sampling of the prostate using a transrectal ultrasonography (TRUS)-guided biopsy. Many specialists have discussed how PSA screening has contributed to underdetection of clinically significant prostate cancer, overdiagnosis of clinically insignificant disease and poor risk stratification; however, little consideration has been given to the role of TRUS-guided biopsy in these errors. The performance of TRUS-guided biopsy is constrained by the biomechanical attributes of the sampling strategy, resulting in suboptimal detection efficiency of each core. By using a biomedical engineering approach, a uniform grid sampling strategy could be used to improve the detection efficiency of prostate biopsy. Moreover, the calibration of the sampling can be adjusted by altering the distance between needle deployments. Our model shows that for any given number of needle trajectories, a uniform grid approach will be superior to a divergent, nonuniform strategy for the detection of clinically important disease. This is an important message that should result in a move away from divergent sampling to a uniform grid approach for prostate biopsy.

  4. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  5. Preparation of tissue samples for X-ray fluorescence microscopy

    International Nuclear Information System (INIS)

    Chwiej, Joanna; Szczerbowska-Boruchowska, Magdalena; Lankosz, Marek; Wojcik, Slawomir; Falkenberg, Gerald; Stegowski, Zdzislaw; Setkowicz, Zuzanna

    2005-01-01

    As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level. The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined. Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg. The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain

  6. Preparation of tissue samples for X-ray fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chwiej, Joanna [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland)]. E-mail: jchwiej@novell.ftj.agh.edu.pl; Szczerbowska-Boruchowska, Magdalena [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Lankosz, Marek [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Wojcik, Slawomir [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Falkenberg, Gerald [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron, Notkestr. 85, Hamburg (Germany); Stegowski, Zdzislaw [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Setkowicz, Zuzanna [Department of Neuroanatomy, Institute of Zoology, Jagiellonian University, Ingardena 6, 30-060 Cracow (Poland)

    2005-12-15

    As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level. The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined. Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg. The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain.

  7. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  8. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  9. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  10. PSA and androgen-related gene (AR, CYP17, and CYP19) polymorphisms and the risk of adenocarcinoma at prostate biopsy

    DEFF Research Database (Denmark)

    dos Santos, Rodrigo Mattos; de Jesus, Carlos Márcio Nóbrega; Trindade Filho, José Carlos Souza

    2008-01-01

    The aim of the present study was to examine the impact of polymorphisms in prostate-specific antigen (PSA) and androgen-related genes (AR, CYP17, and CYP19) on prostate cancer (PCa) risk in selected high-risk patients who underwent prostate biopsy. Blood samples and prostate tissues were obtained......=0.0110) genotypes. Genetic instability at the AR locus leading to somatic mosaicism was detected in one PCa patient by comparing the length of AR CAG repeats in matched peripheral blood and prostate biopsy cores. Taken together, these findings suggest that the PSA genotype should be a clinically relevant biomarker...

  11. ALP gene expression in cDNA samples from bone tissue engineering using a HA/TCP/Chitosan scaffold

    Science.gov (United States)

    Stephanie, N.; Katarina, H.; Amir, L. R.; Gunawan, H. A.

    2017-08-01

    This study examined the potential use of hydroxyapatite (HA)/tricalcium phosphate (TCP)/Chitosan as a bone tissue engineering scaffold. The potential for using HA/TCP/chitosan as a scaffold was analyzed by measuring expression of the ALP osteogenic gene in cDNA from bone biopsies from four Macaque nemestrina. Experimental conditions included control (untreated), treatment with HA/TCP 70:30, HA/TCP 50:50, and HA/TCP/chitosan. cDNA samples were measured quantitively with Real-Time PCR (qPCR) and semi-quantitively by gel electrophoresis. There were no significant differences in ALP gene expression between treatment subjects after two weeks, but the HA/TCP/chitosan treatment gave the highest level of expression after four weeks. The scaffold using the HA/TCP/chitosan combination induced a higher level of expression of the osteogenic gene ALP than did scaffold without chitosan.

  12. Comparison between preoperative biopsy and post-excision ...

    African Journals Online (AJOL)

    peripheral nerve sheath tumour (6%).[6] Soft-tissue sarcomas most frequently affect the extremities and include MFH (40%), lipo- sarcoma (25%), synovial sarcoma and fibrosarcoma.[7]. Appropriate management is reliant on an accurate preoperative histology result. Excision biopsy is recommended for tumours. <3 cm in ...

  13. Circulating tumor DNA functions as an alternative for tissue to overcome tumor heterogeneity in advanced gastric cancer.

    Science.gov (United States)

    Gao, Jing; Wang, Haixing; Zang, Wanchun; Li, Beifang; Rao, Guanhua; Li, Lei; Yu, Yang; Li, Zhongwu; Dong, Bin; Lu, Zhihao; Jiang, Zhi; Shen, Lin

    2017-09-01

    Overcoming tumor heterogeneity is a major challenge for personalized treatment of gastric cancer, especially for human epidermal growth factor receptor-2 targeted therapy. Analysis of circulating tumor DNA allows a more comprehensive analysis of tumor heterogeneity than traditional biopsies in lung cancer and breast cancer, but little is known in gastric cancer. We assessed mutation profiles of ctDNA and primary tumors from 30 patients with advanced gastric cancer, then performed a comprehensive analysis of tumor mutations by multiple biopsies from five patients, and finally analyzed the concordance of HER2 amplification in ctDNA and paired tumor tissues in 70 patients. By comparing with a single tumor sample, ctDNA displayed a low concordance of mutation profile, only approximately 50% (138/275) somatic mutations were found in paired tissue samples, however, when compared with multiple biopsies, most DNA mutations in ctDNA were also shown in paired tumor tissues. ctDNA had a high concordance (91.4%, Kappa index = 0.784, P < 0.001) of HER2 amplification with tumor tissues, suggesting it might be an alternative for tissue. It implied that ctDNA-based assessment could partially overcome the tumor heterogeneity, and might serve as a potential surrogate for HER2 analysis in gastric cancer. © 2017 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  14. TISSUE INHIBITOR OF METALLOPROTEINASE 1, MATRIX METALLOPROTEINASE 9, ALPHA-1 ANTITRYPSIN, METALLOTHIONEIN AND UROKINASE TYPE PLASMINOGEN ACTIVATOR RECEPTOR IN SKIN BIOPSIES FROM PATIENTS AFFECTED BY AUTOIMMUNE BLISTERING DISEASES

    Directory of Open Access Journals (Sweden)

    Ana Maria Abreu Velez

    2013-07-01

    Full Text Available Introduction: Proteinases and proteinase inhibitors have been described to play a role in autoimmune skin blistering diseases. We studied skin lesional biopsies from patients affected by several autoimmune skin blistering diseases for proteinases and proteinase inhibitors. Methods: We utilized immunohistochemistry to evaluate biopsies for alpha-1-antitrypsin, human matrix metalloproteinase 9 (MMP9, human tissue inhibitor of metalloproteinases 1 (TIMP-1, metallothionein and urokinase type plasminogen activator receptor (uPAR. We tested 30 patients affected by endemic pemphigus, 30 controls from the endemic area, and 15 normal controls. We also tested 30 biopsies from patients with bullous pemphigoid (BP, 20 with pemphigus vulgaris (PV, 8 with pemphigus foliaceus, and 14 with dermatitis herpetiformis (DH. Results: Contrary to findings in the current literature, most autoimmune skin blistering disease biopsies were negative for uPAR and MMP9. Only some chronic patients with El Bagre-EPF were positive to MMP9 in the dermis, in proximity to telocytes. TIMP-1 and metallothionein were positive in half of the biopsies from BP patients at the basement membrane of the skin, within several skin appendices, in areas of dermal blood vessel inflammation and within dermal mesenchymal-epithelial cell junctions.

  15. Correlation between virulence markers of Helicobacter pylori in the oral cavity and gastric biopsies

    Directory of Open Access Journals (Sweden)

    Myriam Lucrecia MEDINA

    2017-07-01

    Full Text Available ABSTRACT BACKGROUND: The clinical outcome of Helicobacter pylori infection has been associated with virulence factors. The presence of these factors is useful as molecular markers in the identification of the high risk for developing severe gastric pathologies. OBJECTIVE: To correlate the presence of virulence markers cagA and bab2A of H. pylori in oral and gastric biopsy samples. METHODS: An observational, prospective, descriptive, and cross-sectional study was carried out between September 2011 and September 2012. Patients suffering dyspepsia with indication for upper gastrointestinal video endoscopy who attended the Gastroenterology Service of the Hospital Dr. Julio C. Perrando were included. Epidemiological investigation was completed. To detect the bacteria and their virulence genes, samples of saliva, dental plaque and gastric biopsy were taken and processed by PCR. RESULTS: Sixty-one patients were selected for this study (30 women and 31 men. H. pylori was detected in 31 gastric biopsies and 31 oral samples. Significant difference between oral and gastric samples was found in cagA genotype. Agreement between oral and gastric genotypes was found in 38.7% of samples from the same patient. CONCLUSION: This study is the first in provide information about the genotypes of the Argentinean Northeast H. pylori strains. Despite the high prevalence of H. pylori infection, the most of patients had less virulent genotypes in oral cavity and gastric tissue. The cagA / babA2 combination was not frequent in the samples studied. There was not a statistical correlation between the virulence genes and gastroduodenal or oral diseases. Although in some patients the same genotype was found both in oral and gastric samples, it cannot be ensure that they corresponding to the same strain because a DNA sequencing was not performed.

  16. Diagnostic Value of ERG in Prostate Needle Biopsies Containing Minute Cancer Foci

    Directory of Open Access Journals (Sweden)

    Bachurska Svitlana Y.

    2017-03-01

    Full Text Available Background: Prostate carcinoma (PC is the second most diagnosed cancer in men population worldwide. The small amount of the tissue in prostate needle biopsy is often sufficient for the correct interpretation. Novel antibodies, as ERG, could add to the diagnostic value of IHC study in analysing difficult core biopsies.

  17. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    International Nuclear Information System (INIS)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.; TenHave, Thomas R.

    1996-01-01

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnostic tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles

  18. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  19. Molecular detection of Coxiella burnetii from the formalin-fixed tissues of Q fever patients with acute hepatitis.

    Directory of Open Access Journals (Sweden)

    Young-Rock Jang

    Full Text Available Serologic diagnosis is one of the most widely used diagnostic methods for Q fever, but the window period in antibody response of 2 to 3 weeks after symptom onset results in significant diagnostic delay. We investigated the diagnostic utility of Q fever PCR from formalin-fixed liver tissues in Q fever patients with acute hepatitis.We reviewed the clinical and laboratory data in patients with Q fever hepatitis who underwent liver biopsy during a 17-year period, and whose biopsied tissues were available. We also selected patients who revealed granuloma in liver biopsy and with no Q fever diagnosis within the last 3 years as control. Acute Q fever hepatitis was diagnosed if two or more of the following clinical, serologic, or histopathologic criteria were met: (1 an infectious hepatitis-like clinical feature such as fever (≥ 38°C with elevated hepatic transaminase levels; (2 exhibition of a phase II immunoglobulin G (IgG antibodies titer by IFA of ≥ 1:128 in single determination, or a four-fold or greater rise between two separate samples obtained two or more weeks apart; (3 histologic finding of biopsy tissue showing characteristic fibrin ring granuloma.A total of 11 patients with acute Q fever hepatitis were selected and analyzed. Of the 11 patients, 3 (27% had exposure to zoonotic risk factors and 7 (63% met the serologic criteria. Granulomas with either circumferential or radiating fibrin deposition were observed in 10 cases on liver biopsy and in 1 case on bone marrow biopsy. 8 (73% revealed positive Coxiella burnetii PCR from their formalin-fixed liver tissues. In contrast, none of 10 patients with alternative diagnosis who had hepatic granuloma revealed positive C. burnetii PCR from their formalin-fixed liver tissues.Q fever PCR from formalin-fixed liver tissues appears to be a useful adjunct for diagnosing Q fever hepatitis.

  20. Automated quantification of renal interstitial fibrosis for computer-aided diagnosis: A comprehensive tissue structure segmentation method.

    Science.gov (United States)

    Tey, Wei Keat; Kuang, Ye Chow; Ooi, Melanie Po-Leen; Khoo, Joon Joon

    2018-03-01

    Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses. This study proposes an automated quantification system for measuring the amount of interstitial fibrosis in renal biopsy images as a consistent basis of comparison among pathologists. The system extracts and segments the renal tissue structures based on colour information and structural assumptions of the tissue structures. The regions in the biopsy representing the interstitial fibrosis are deduced through the elimination of non-interstitial fibrosis structures from the biopsy area and quantified as a percentage of the total area of the biopsy sample. A ground truth image dataset has been manually prepared by consulting an experienced pathologist for the validation of the segmentation algorithms. The results from experiments involving experienced pathologists have demonstrated a good correlation in quantification result between the automated system and the pathologists' visual evaluation. Experiments investigating the variability in pathologists also proved the automated quantification error rate to be on par with the average intra-observer variability in pathologists' quantification. Interstitial fibrosis in renal biopsy samples is a scarring tissue structure that may be visually quantified by pathologists as an indicator to the presence and extent of chronic kidney disease. The standard method of quantification by visual evaluation presents reproducibility issues in the diagnoses due to the uncertainties in human judgement. An automated quantification system for accurately measuring the amount of interstitial fibrosis in renal biopsy images is presented as a consistent basis of comparison among pathologists. The system identifies the renal tissue structures

  1. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  2. Analysis of lung tissue using ion beams

    International Nuclear Information System (INIS)

    Alvarez, J.L.; Barrera, R.; Miranda, J.

    2002-01-01

    In this work a comparative study is presented of the contents of metals in lung tissue from healthy patients and with lung cancer, by means of two analytical techniques: Particle Induced X-ray Emission (PIXE) and Rutherford Backscattering Spectrometry (RBS). The samples of cancerous tissue were taken from 26 autopsies made to individuals died in the National Institute of Respiratory Disease (INER), 22 of cancer and 4 of other non-cancer biopsies. When analyzing the entirety of the samples, in the cancerous tissues, there were increments in the concentrations of S (4%), K (635%), Co (85%) and Cu (13%). Likewise, there were deficiencies in the concentrations of Cl (59%), Ca (6%), Fe (26%) and Zn (7%). Only in the cancerous tissues there were appearances of P, Ca, Ti, V, Cr, Mn, Ni, Br and Sr. The tissue samples were classified according to cancer types (adenocarcinomas, epidermoides and of small cell carcinoma), personal habits (smokers and alcoholic), genetic predisposition and residence place. There was a remarkable decrease in the concentration of Ca and a marked increment in the Cu in the epidermoide tissue samples with regard to those of adenocarcinoma or of small cells cancer. Also, decrements were detected in K and increments of Fe, Co and Cu in the sample belonging to people that resided in Mexico City with regard to those that resided in the State of Mexico

  3. Advantages of stereotaxic needle biopsy of brain tumor using interventional magnetic resonance imaging. Report of 12 cases

    International Nuclear Information System (INIS)

    Terao, Tohru; Hashimoto, Takuo; Koyama, Tsutomu; Takahashi, Koichi; Harada, Junta; Abe, Toshiaki

    1998-01-01

    Interventional MRI, an advanced neuroimaging system, was used to perform stereotaxic needle biopsy of brain tissue (AIRIS, 0.3 Tesla, Hitachi) in 12 patients (9 males, 3 females) with intraparenchymal abnormal lesions. This system permits accurate and safe biopsy of brain tissue in real time. Patient ages ranged from 31 to 79 years (mean 61.5 years). We evaluated the abnormal lesion and dominant hemisphere of these patients preoperatively by using CT, MRI and cerebral angiography. Lesions were located in the left frontal lobe in 3 cases, the right frontal lobe in 1 case, the left temporal lobe in 1 case, the right temporal lobe in 1 case, the left parietal lobe in 2 cases, the right parietal lobe in 1 case, the left occipital lobe in 1 case, the bilateral basal ganglia in 1 case and the corpus callosum in 1 case. The sampling points were in the dominant hemisphere in 7 cases and in the non-dominant hemisphere in 5 cases. The diagnosis based on stereotaxic needle biopsy using this system were 4 gliomas, 1 brain abscess, 1 metastatic brain tumor, 1 granuloma, 2 cerebral infarctions, 2 malignant lymphomas and 1 normal brain tissue. Success rate of biopsy for our 12 cases using this system was 91.7%. Brain hemorrhage was a complication in 1 case but there was no case of meningitis or convulsion. This method is useful in patients with inoperable lesions, including deep lesion or lesions in the brainstem diencephalon or dominant hemisphere, in patients with serious complications, and in geriatric patients. In the future, this MRI system may be applied to minimally invasive therapies such as tumor ablation, cryosurgery, chemoablation, and ventrolateral thalamotomy for parkinsonism. (author)

  4. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  5. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  6. Nucleic Acid Amplification Testing and Sequencing Combined with Acid-Fast Staining in Needle Biopsy Lung Tissues for the Diagnosis of Smear-Negative Pulmonary Tuberculosis.

    Science.gov (United States)

    Jiang, Faming; Huang, Weiwei; Wang, Ye; Tian, Panwen; Chen, Xuerong; Liang, Zongan

    2016-01-01

    Smear-negative pulmonary tuberculosis (PTB) is common and difficult to diagnose. In this study, we investigated the diagnostic value of nucleic acid amplification testing and sequencing combined with acid-fast bacteria (AFB) staining of needle biopsy lung tissues for patients with suspected smear-negative PTB. Patients with suspected smear-negative PTB who underwent percutaneous transthoracic needle biopsy between May 1, 2012, and June 30, 2015, were enrolled in this retrospective study. Patients with AFB in sputum smears were excluded. All lung biopsy specimens were fixed in formalin, embedded in paraffin, and subjected to acid-fast staining and tuberculous polymerase chain reaction (TB-PCR). For patients with positive AFB and negative TB-PCR results in lung tissues, probe assays and 16S rRNA sequencing were used for identification of nontuberculous mycobacteria (NTM). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of PCR and AFB staining were calculated separately and in combination. Among the 220 eligible patients, 133 were diagnosed with TB (men/women: 76/57; age range: 17-80 years, confirmed TB: 9, probable TB: 124). Forty-eight patients who were diagnosed with other specific diseases were assigned as negative controls, and 39 patients with indeterminate final diagnosis were excluded from statistical analysis. The sensitivity, specificity, PPV, NPV, and accuracy of histological AFB (HAFB) for the diagnosis of smear-negative were 61.7% (82/133), 100% (48/48), 100% (82/82), 48.5% (48/181), and 71.8% (130/181), respectively. The sensitivity, specificity, PPV, and NPV of histological PCR were 89.5% (119/133), 95.8% (46/48), 98.3% (119/121), and 76.7% (46/60), respectively, demonstrating that histological PCR had significantly higher accuracy (91.2% [165/181]) than histological acid-fast staining (71.8% [130/181]), P pulmonary tuberculosis. For patients with positive histological AFB and

  7. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  8. Persistent organic pollutants and stable isotopes in biopsy samples (2004/2006) from Southern Resident killer whales

    Energy Technology Data Exchange (ETDEWEB)

    Krahn, Margaret M. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States)], E-mail: peggy.krahn@noaa.gov; Hanson, M. Bradley [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States); Baird, Robin W. [Cascadia Research, 218 1/2 W, 4th Avenue, Olympia, WA 98501 (United States); Boyer, Richard H.; Burrows, Douglas G.; Emmons, Candice K. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States); Ford, John K.B. [Fisheries and Oceans Canada, Pacific Biological Station, Nanaimo, BC, V9R 5K6 (Canada); Jones, Linda L.; Noren, Dawn P. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States); Ross, Peter S. [Fisheries and Oceans Canada, Institute of Ocean Sciences, P.O. Box 6000, Sidney, BC, V8L 4B2 (Canada); Schorr, Gregory S. [Cascadia Research, 218 1/2 W, 4th Avenue, Olympia, WA 98501 (United States); Collier, Tracy K. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States)

    2007-12-15

    'Southern Resident' killer whales include three 'pods' (J, K and L) that reside primarily in Puget Sound/Georgia Basin during the spring, summer and fall. This population was listed as 'endangered' in the US and Canada following a 20% decline between 1996 and 2001. The current study, using blubber/epidermis biopsy samples, contributes contemporary information about potential factors (i.e., levels of pollutants or changes in diet) that could adversely affect Southern Residents. Carbon and nitrogen stable isotopes indicated J- and L-pod consumed prey from similar trophic levels in 2004/2006 and also showed no evidence for a large shift in the trophic level of prey consumed by L-pod between 1996 and 2004/2006. {sigma}PCBs decreased for Southern Residents biopsied in 2004/2006 compared to 1993-1995. Surprisingly, however, a three-year-old male whale (J39) had the highest concentrations of {sigma}PBDEs, {sigma}HCHs and HCB. POP ratio differences between J- and L-pod suggested that they occupy different ranges in winter.

  9. Methods of Assessing Human Tendon Metabolism and Tissue Properties in Response to Changes in Mechanical Loading

    DEFF Research Database (Denmark)

    Heinemeier, Katja M; Kjaer, Michael; Magnusson, S Peter

    2016-01-01

    expression as well as protein synthesis rate. Further the (14)C bomb-pulse method has provided data on long-term tissue turnover in human tendon. Non-invasive techniques allow measurement of tendon metabolism (positron emission tomography (PET)), tendon morphology (magnetic resonance imaging (MRI......In recent years a number of methodological developments have improved the opportunities to study human tendon. Microdialysis enables sampling of interstitial fluid in the peritendon tissue, while sampling of human tendon biopsies allows direct analysis of tendon tissue for gene- and protein...

  10. The Incidence of Malignant Infiltration in the Biopsy Tract of Osteosarcoma

    Directory of Open Access Journals (Sweden)

    R Mohana

    2007-11-01

    Full Text Available Biopsy is a crucial step in the management of musculoskeletal sarcoma. The surgical approach to the biopsy site is important, as the tract must be removed en bloc with the tumour during limb sparing surgery so as to reduce the risk of local recurrence. The biopsy tracts of 26 osteosarcoma patients were evaluated histologically for tumour infiltration. Horizontal sections of 1 mm thickness with 2 cm radius from were evaluated from each excised biopsy tract. Five out of 26 cases (19.2% showed positive tumour infiltration. One case (3.85% had tumour infiltration in the pseudocapsule, two cases (7.69% had tumour infiltration into the muscle and two other cases (7.69% had tumour infiltration into the subcutaneous tissue. None had skin infiltration. We conclude that resection of the entire biopsy tract is indeed mandatory for surgical treatment of osteosarcoma.

  11. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik [Chungang Gil Hospital, Incheon (Korea, Republic of)

    1997-11-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US.

  12. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik

    1997-01-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US

  13. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  14. USAXS and SAXS from cancer-bearing breast tissue samples

    International Nuclear Information System (INIS)

    Fernandez, M.; Suhonen, H.; Keyrilaeinen, J.; Bravin, A.; Fiedler, S.; Karjalainen-Lindsberg, M.-L.; Leidenius, M.; Smitten, K. von; Suortti, P.

    2008-01-01

    USAXS and SAXS patterns from cancer-bearing human breast tissue samples were recorded at beamline ID02 of the ESRF using a Bonse-Hart camera and a pinhole camera. The samples were classified as being ductal carcinoma, grade II, and ductal carcinoma in situ, partly invasive. The samples included areas of healthy collagen, invaded collagen, necrotic ducts with calcifications, and adipose tissue. The scattering patterns were analyzed in different ways to separate the scattering contribution and the direct beam from the observed rocking curve (RC) of the analyzer. It was found that USAXS from all tissues was weak, and the effects on the analyzer RC were observed only in the low-intensity tails of the patterns. The intrinsic RC was convolved with different model functions for the impulse response of the sample, and the best fit with experiment was obtained by the Pearson VII function. Significantly different distributions for the Pearson exponent m were obtained in benign and malignant regions of the samples. For a comparison with analyzer-based imaging (ABI) or diffraction enhanced imaging (DEI) a 'long-slit' integration of the patterns was performed, and this emphasized the scattering contribution in the tails of the rocking curve

  15. High-throughput sequencing approach uncovers the miRNome of peritoneal endometriotic lesions and adjacent healthy tissues.

    Directory of Open Access Journals (Sweden)

    Merli Saare

    Full Text Available Accumulating data have shown the involvement of microRNAs (miRNAs in endometriosis pathogenesis. In this study, we used a novel approach to determine the endometriotic lesion-specific miRNAs by high-throughput small RNA sequencing of paired samples of peritoneal endometriotic lesions and matched healthy surrounding tissues together with eutopic endometria of the same patients. We found five miRNAs specific to epithelial cells--miR-34c, miR-449a, miR-200a, miR-200b and miR-141 showing significantly higher expression in peritoneal endometriotic lesions compared to healthy peritoneal tissues. We also determined the expression levels of miR-200 family target genes E-cadherin, ZEB1 and ZEB2 and found that the expression level of E-cadherin was significantly higher in endometriotic lesions compared to healthy tissues. Further evaluation verified that studied miRNAs could be used as diagnostic markers for confirming the presence of endometrial cells in endometriotic lesion biopsy samples. Furthermore, we demonstrated that the miRNA profile of peritoneal endometriotic lesion biopsies is largely masked by the surrounding peritoneal tissue, challenging the discovery of an accurate lesion-specific miRNA profile. Taken together, our findings indicate that only particular miRNAs with a significantly higher expression in endometriotic cells can be detected from lesion biopsies, and can serve as diagnostic markers for endometriosis.

  16. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  17. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Peter R., E-mail: pmarti46@uwo.ca [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Cool, Derek W. [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7, Canada and Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Romagnoli, Cesare [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Fenster, Aaron [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Ward, Aaron D. [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each

  18. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D

    2014-07-01

    Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided "fusion" prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm(3) or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using

  19. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    International Nuclear Information System (INIS)

    Martin, Peter R.; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-01-01

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm 3 or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was

  20. The Diagnosis of Gastric Mucosa-associated Lymphoid Tissue Lymphoma by Flow Cytometry and Fluorescence in situ Hybridization of Biopsy Specimens.

    Science.gov (United States)

    Matsueda, Katsunori; Omote, Sizuma; Sakata, Masahiro; Fujita, Isao; Horii, Jouichiro; Toyokawa, Tatsuya

    2018-04-15

    Mucosa-associated lymphoid tissue (MALT) lymphoma and reactive inflammatory lymphoid changes are frequently difficult to distinguish based on a routine histological differential diagnosis. We were unable to diagnose gastric MALT lymphoma histologically using specimens obtained by endoscopy, although a flow cytometry (FCM) analysis demonstrated clonality of neoplastic cells by separating cells by CD45 gating. Furthermore, a fluorescence in situ hybridization (FISH) analysis showed trisomy 18. We therefore diagnosed gastric MALT lymphoma with trisomy 18. We recommend that FCM and FISH analyses of biopsy specimens be considered for diagnosing gastric MALT lymphoma if this diagnosis is suspected based on endoscopic findings.

  1. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  2. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  3. Phosphotyrosine-based-phosphoproteomics scaled-down to biopsy level for analysis of individual tumor biology and treatment selection.

    Science.gov (United States)

    Labots, Mariette; van der Mijn, Johannes C; Beekhof, Robin; Piersma, Sander R; de Goeij-de Haas, Richard R; Pham, Thang V; Knol, Jaco C; Dekker, Henk; van Grieken, Nicole C T; Verheul, Henk M W; Jiménez, Connie R

    2017-06-06

    Mass spectrometry-based phosphoproteomics of cancer cell and tissue lysates provides insight in aberrantly activated signaling pathways and potential drug targets. For improved understanding of individual patient's tumor biology and to allow selection of tyrosine kinase inhibitors in individual patients, phosphoproteomics of small clinical samples should be feasible and reproducible. We aimed to scale down a pTyr-phosphopeptide enrichment protocol to biopsy-level protein input and assess reproducibility and applicability to tumor needle biopsies. To this end, phosphopeptide immunoprecipitation using anti-phosphotyrosine beads was performed using 10, 5 and 1mg protein input from lysates of colorectal cancer (CRC) cell line HCT116. Multiple needle biopsies from 7 human CRC resection specimens were analyzed at the 1mg-level. The total number of phosphopeptides captured and detected by LC-MS/MS ranged from 681 at 10mg input to 471 at 1mg HCT116 protein. ID-reproducibility ranged from 60.5% at 10mg to 43.9% at 1mg. Per 1mg-level biopsy sample, >200 phosphopeptides were identified with 57% ID-reproducibility between paired tumor biopsies. Unsupervised analysis clustered biopsies from individual patients together and revealed known and potential therapeutic targets. This study demonstrates the feasibility of label-free pTyr-phosphoproteomics at the tumor biopsy level based on reproducible analyses using 1mg of protein input. The considerable number of identified phosphopeptides at this level is attributed to an effective down-scaled immuno-affinity protocol as well as to the application of ID propagation in the data processing and analysis steps. Unsupervised cluster analysis reveals patient-specific profiles. Together, these findings pave the way for clinical trials in which pTyr-phosphoproteomics will be performed on pre- and on-treatment biopsies. Such studies will improve our understanding of individual tumor biology and may enable future p

  4. An evaluation of in-office flexible fiber-optic biopsies for laryngopharyngeal lesions.

    Science.gov (United States)

    Lee, Francisco; Smith, Kristine A; Chandarana, Shamir; Matthews, T Wayne; Bosch, J Douglas; Nakoneshny, Steven C; Dort, Joseph C

    2018-05-09

    Operative endoscopy and flexible fiber-optic in-office tissue biopsy are common techniques to assess suspicious laryngopharyngeal lesions. The primary outcome was the delay to the initiation of treatment. Secondary outcomes were delay to biopsy, histopathological diagnosis, and assessment at a multidisciplinary oncology clinic. A retrospective analysis was performed to assess the relative delays between these approaches to biopsy of laryngopharyngeal lesions. There were 114 patients in the study cohort; 44 in-office and 70 operative endoscopic biopsies). The mean delay from consultation to biopsy was 17.4 days for the operative endoscopy group and 1.3 days for the in-office group. The mean delay from initial otolaryngology consultation to initiation of treatment was 51.7 days and 44.6 days for the operative endoscopy and in-office groups, respectively. In-office biopsy reduced the time from initial consultation to biopsy. The temporal gains via in-office biopsy did not translate into faster access to treatment. This outcome highlights the opportunity to improve access to treatment for patients with early diagnosis.

  5. X-ray scattering for the characterization of lyophilized breast tissue samples

    International Nuclear Information System (INIS)

    Elshemey, Wael M.; Mohamed, Fayrouz S.; Khater, Ibrahim M.

    2013-01-01

    This work investigates the possibility of characterizing breast cancer by measuring the X-ray scattering profiles of lyophilized excised breast tissue samples. Since X-ray scattering from water-rich tissue is dominated by scattering from water, the removal of water by lyophilization would enhance the characterization process. In the present study, X-ray scattering profiles of 22 normal, 22 malignant and 10 benign breast tissue samples are measured. The cut-offs of scatter diagrams, sensitivity, specificity and diagnostic accuracy of three characterization parameters (full width at half maximum (FWHM) for the peak at 1.1 nm −1 , area under curve (AUC), and ratio of 1st to 2nd scattering peak intensities (I 1 /I 2 %)) are calculated and compared to the data from non-lyophilized samples. Results show increased sensitivity (up to 100%) of the present data on lyophilized breast tissue samples compared to previously reported data for non-lyophilized samples while the specificity (up to 95.4%), diagnostic accuracy (up to 95.4%) and receiver operating characteristic (ROC) curve values (up to 0.9979) for both sets of data are comparable. The present study shows significant differences between normal samples and each of malignant and benign samples. Only subtle differences exist between malignant and benign lyophilized breast tissue samples where FWHM=0.7±0.1 and 0.8±0.3, AUC=1.3±0.2 and 1.4±0.2 and I 1 /I 2 %=44.9±11.0 and 52.4±7.6 for malignant and benign samples respectively. - Highlights: • X-ray scattering profiles of breast tissue samples are acquired. • Three X-ray profile characterization parameters are calculated. • The cut-offs, sensitivity, specificity and diagnostic accuracy are calculated. • They are compared to the data from non-lyophilized samples. • Results show increased sensitivity in case of lyophilized samples

  6. An optimized staining technique for the detection of Gram positive and Gram negative bacteria within tissue.

    Science.gov (United States)

    Becerra, Sandra C; Roy, Daniel C; Sanchez, Carlos J; Christy, Robert J; Burmeister, David M

    2016-04-12

    Bacterial infections are a common clinical problem in both acute and chronic wounds. With growing concerns over antibiotic resistance, treatment of bacterial infections should only occur after positive diagnosis. Currently, diagnosis is delayed due to lengthy culturing methods which may also fail to identify the presence of bacteria. While newer costly bacterial identification methods are being explored, a simple and inexpensive diagnostic tool would aid in immediate and accurate treatments for bacterial infections. Histologically, hematoxylin and eosin (H&E) and Gram stains have been employed, but are far from optimal when analyzing tissue samples due to non-specific staining. The goal of the current study was to develop a modification of the Gram stain that enhances the contrast between bacteria and host tissue. A modified Gram stain was developed and tested as an alternative to Gram stain that improves the contrast between Gram positive bacteria, Gram negative bacteria and host tissue. Initially, clinically relevant strains of Pseudomonas aeruginosa and Staphylococcus aureus were visualized in vitro and in biopsies of infected, porcine burns using routine Gram stain, and immunohistochemistry techniques involving bacterial strain-specific fluorescent antibodies as validation tools. H&E and Gram stain of serial biopsy sections were then compared to a modification of the Gram stain incorporating a counterstain that highlights collagen found in tissue. The modified Gram stain clearly identified both Gram positive and Gram negative bacteria, and when compared to H&E or Gram stain alone provided excellent contrast between bacteria and non-viable burn eschar. Moreover, when applied to surgical biopsies from patients that underwent burn debridement this technique was able to clearly detect bacterial morphology within host tissue. We describe a modification of the Gram stain that provides improved contrast of Gram positive and Gram negative microorganisms within host

  7. Extended analysis of AL-amyloid protein from abdominal wall subcutaneous fat biopsy

    DEFF Research Database (Denmark)

    Olsen, K E; Sletten, K; Westermark, Per

    1998-01-01

    a subcutaneous fat tissue biopsy and submitted to extended protein separation, typing and amino acid sequence analyses. The AL-protein belonged to the rare immunoglobulin light chain kappa, subtype kappa IV and contained unique amino acid substitutions, mostly in the highly preserved framework regions. The study...... shows that subcutaneous fat biopsies are useful sources of amyloid material for biochemical studies....

  8. Human papillomavirus in anal biopsy tissues and liquid-based cytology samples of HIV-positive and HIV-negative Thai men who have sex with men

    Directory of Open Access Journals (Sweden)

    Tippawan Pankam

    2017-06-01

    Full Text Available Background: Men who have sex with men (MSM are at high risk of developing human papillomavirus (HPV-related anal cancer. We compared HPV genotypes in anal tissues (Bx and anal liquid-based cytology fluid (LBC from HIV-positive and HIV-negative MSM. Methods: Bx (32 normal, 41 low-grade squamous intraepithelial lesions (LSIL and 22 high-grade squamous intraepithelial lesions (HSIL, along with LBC from the same visit, were selected from 61 HIV-positive and 34 HIV-negative MSM who enrolled into a prospective cohort in Bangkok, Thailand. HPV genotyping was performed on Bx and LBC. Results: Any HPV and high-risk HPV (HR-HPV prevalence were 63.2% and 60.0% in Bx and 71.6% and 62.1% in LBC, respectively. HIV-positive MSM had higher rates of HR-HPV genotypes detection (70.5% vs. 47.1%, p=0.03 in LBC than HIV-negative MSM. HPV16 (27% was the most common HR-HPV found in HSIL tissue. In HIV-positive MSM, the frequency of HR-HPV detection increased with histopathologic grading in both Bx and LBC samples. HSIL was associated with the presence of any HR-HPV(OR 7.6 (95%CI 1.8–31.9; P=0.006 in LBC and in Bx((OR 5.6 (95%CI 1.4–22.7; P=0.02. Conclusions: Our data strongly support the integration of HR-HPV screening on LBC samples, along with HPV vaccination, into an anal cancer prevention program. Keywords: Human papillomavirus, Anal tissues, Men who have sex with men, HIV, Thailand

  9. THE ANTI-TB DRUG SENSITIVITY OF MYCOBACTERIUM TUBERCULOSIS FROM CEREBROSPINAL FLUID AND BONE TISSUE BIOPSY SPECIMENS OF PATIENTS SUSPECTED TUBERCULOUS MENINGITIS AND SPINAL TB IN DR SOETOMO HOSPITAL INDONESIA

    Directory of Open Access Journals (Sweden)

    Ni Made Mertaniasih

    2014-09-01

    Full Text Available Tuberculous meningitis (TBM is an infection of meningens which potentially life threatening with significant morbidity and mortality. Spinal TB has the same problem with TBM, infection in bone and joint, the delayed diagnosis worsens the prognosis. The rapid and accurate diagnosis plus promt adequate treatment is essential for the good outcome. The aim of this research is to study the first line drug sensitivity of Mycobacterium tuberculosis isolated from specimens of cerebrospinal fluid from suspected tuberculous meningitis patients and bone tissue biopsy from suspected spinal TB patients. The method of this research is TB Laboratory examination in Department of Clinical Microbiology – Dr. Soetomo General Hospital, Indonesia, using the gold standard liquid culture method MGIT 960 System (Becton Dickinson and solid culture method with Lowenstein-Jensen medium. The specimens CSF from 50 TBM patients at January 2013 until May 2014. Positive isolate detection of Mycobacterium tuberculosis complex were 11 isolates (22%, which sensitivity 100% (11/11 isolates to Rifampin (R, Pyrazinamide (Z, Ethambutol (E, and Streptomycin (S; one isolate resistant to Isoniazid, sensitivity to Isoniazid 90,90% (10/11; and received 21 specimens of bone tissue biopsy which positive 5 isolates (23%, all isolates sensitive 100% (5/5 isolates to Rifampin and Pyrazinamide, and 1 isolates resistant to Isoniazid, Ethambutol, and Streptomycin, in which sensitivity 80% (4/5 isolates to Isoniazid, Ethambutol, and Streptomycin. The conclusion of this research is positivity detection 22% of CSF specimens, and 23% of bone tissue biopsy were low. All isolates sensitive 100% to Rifampin and Pyrazinamide, and 80-90% sensitive to Isoniazid.

  10. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  11. Relationship between histopathological changes in post partum renal biopsies and renal function tests of African women with early onset pre-eclampsia.

    Science.gov (United States)

    Khedun, S M; Naicker, T; Moodley, J

    2000-05-01

    To improve the diagnostic accuracy of concurrent renal disease in hypertension of pregnancy, biopsy evaluation is essential. In addition, establishing underlying renal disease is important for prognosis on future pregnancies. We therefore designed a study to determine the diagnostic yield of postpartum renal biopsy and the nature and frequency of complications associated with this procedure. Also, to determine relationships, if any, between renal function tests and ultrastructural and histopathological findings. Fifty renal biopsies were performed in the immediate postpartum period in black African women with early onset pre-eclampsia. Each biopsy specimen was placed in a separate container and coded so that sampling was unknown to the electron microscopist. Each biopsy specimen was divided into three parts, and processed and stained for light, fluorescent and transmission electron microscopy using conventional techniques. Renal tissue biopsies were adequate for diagnostic purposes in all cases. There were no complications in any of the 50 patients studied. Ultrastructural examination confirmed the light microscopy findings. In addition the ultrastructural findings showed intramembranous deposits, foot process fusion and mesangial deposits. In 16 patients with normal renal function tests; the biopsies evaluation from these patients showed ultrastructural changes. In the remaining 34 patients with abnormal renal function tests of varying severity; biopsy evaluation from these patients showed both ultrastructural and histopathological changes. Renal biopsy procedure is safe, and ultrastructural and histological findings obtained from postpartum renal biopsies are more informative than the routine renal function tests.

  12. Variability of protein level and phosphorylation status caused by biopsy protocol design in human skeletal muscle analyses

    Directory of Open Access Journals (Sweden)

    Caron Marc-André

    2011-11-01

    Full Text Available Abstract Background Bergström needle biopsy is widely used to sample skeletal muscle in order to study cell signaling directly in human tissue. Consequences of the biopsy protocol design on muscle protein quantity and quality remain unclear. The aim of the present study was to assess the impact of different events surrounding biopsy protocol on the stability of the Western blot signal of eukaryotic translation initiation factor 4E binding protein 1 (4E-BP1, Akt, glycogen synthase kinase-3β (GSK-3β, muscle RING finger protein 1 (MuRF1 and p70 S6 kinase (p70 S6K. Six healthy subjects underwent four biopsies of the vastus lateralis, distributed into two distinct visits spaced by 48 hrs. At visit 1, a basal biopsy in the right leg was performed in the morning (R1 followed by a second in the left leg in the afternoon (AF. At visit 2, a second basal biopsy (R2 was collected from the right leg. Low intensity mobilization (3 × 20 right leg extensions was performed and a final biopsy (Mob was collected using the same incision site as R2. Results Akt and p70 S6K phosphorylation levels were increased by 83% when AF biopsy was compared to R1. Mob condition induced important phosphorylation of p70 S6K when compared to R2. Comparison of R1 and R2 biopsies revealed a relative stability of the signal for both total and phosphorylated proteins. Conclusions This study highlights the importance to standardize muscle biopsy protocols in order to minimize the method-induced variation when analyzing Western blot signals.

  13. Percutaneous Renal Biopsy : A Report of 200 Caces

    Directory of Open Access Journals (Sweden)

    M. Bahadori

    1966-01-01

    Full Text Available In the diffuse medical diseases of kidney, percutaneous renal biopsy is a valuable, safe and hazardless procedure. With the aid of this nearly new technique renal pathology, the natural history of renal diseases and the response of renal diseases to therapy, as well as the prognosis of renal disorders can be evaluated."nWe have analysed 210 percutaneous biopsies in Tehran. Complications were observed in 13% of cases, there is no mortality and no patient required drastic therapeutic intervention. Anuria, peri-renal colic and peri-renal hematoma were the only serious complications, which were seen in 4 patients, and were. readily controled with simple measures We obtained renal tissue in 95% cases of our patients and in 9 I% of them the tissue was adequate for c'ear diagnosis."nLike other authors, we believe that the procedure, when properly performed, can give a far more valuable informations about the patients without any realy dangerous risk.

  14. Histologic examination of hepatic biopsy samples as a prognostic indicator in dogs undergoing surgical correction of congenital portosystemic shunts: 64 cases (1997-2005).

    Science.gov (United States)

    Parker, Jacquelyn S; Monnet, Eric; Powers, Barbara E; Twedt, David C

    2008-05-15

    To determine whether results of histologic examination of hepatic biopsy samples could be used as an indicator of survival time in dogs that underwent surgical correction of a congenital portosystemic shunt (PSS). Retrospective case series. 64 dogs that underwent exploratory laparotomy for an extrahepatic (n = 39) or intrahepatic (25) congenital PSS. All H&E-stained histologic slides of hepatic biopsy samples obtained at the time of surgery were reviewed by a single individual, and severity of histologic abnormalities (ie, arteriolar hyperplasia, biliary hyperplasia, fibrosis, cell swelling, lipidosis, lymphoplasmacytic cholangiohepatitis, suppurative cholangiohepatitis, lipid granulomas, and dilated sinusoids) was graded. A Cox proportional hazards regression model was used to determine whether each histologic feature was associated with survival time. Median follow-up time was 35.7 months, and median survival time was 50.6 months. Thirty-eight dogs were alive at the time of final follow-up; 15 had died of causes associated with the PSS, including 4 that died immediately after surgery; 3 had died of unrelated causes; and 8 were lost to follow-up. None of the histologic features examined were significantly associated with survival time. Findings suggested that results of histologic examination of hepatic biopsy samples obtained at the time of surgery cannot be used to predict long-term outcome in dogs undergoing surgical correction of a PSS.

  15. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  16. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  17. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  18. Clinical utility of an epigenetic assay to detect occult prostate cancer in histopathologically negative biopsies: results of the MATLOC study.

    Science.gov (United States)

    Stewart, Grant D; Van Neste, Leander; Delvenne, Philippe; Delrée, Paul; Delga, Agnès; McNeill, S Alan; O'Donnell, Marie; Clark, James; Van Criekinge, Wim; Bigley, Joseph; Harrison, David J

    2013-03-01

    Concern about possible false-negative prostate biopsy histopathology findings often leads to rebiopsy. A quantitative methylation specific polymerase chain reaction assay panel, including GSTP1, APC and RASSF1, could increase the sensitivity of detecting cancer over that of pathological review alone, leading to a high negative predictive value and a decrease in unnecessary repeat biopsies. The MATLOC study blindly tested archived prostate biopsy needle core tissue samples of 498 subjects from the United Kingdom and Belgium with histopathologically negative prostate biopsies, followed by positive (cases) or negative (controls) repeat biopsy within 30 months. Clinical performance of the epigenetic marker panel, emphasizing negative predictive value, was assessed and cross-validated. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay performed on the first negative biopsies of this retrospective review cohort resulted in a negative predictive value of 90% (95% CI 87-93). In a multivariate model correcting for patient age, prostate specific antigen, digital rectal examination and first biopsy histopathological characteristics the epigenetic assay was a significant independent predictor of patient outcome (OR 3.17, 95% CI 1.81-5.53). A multiplex quantitative methylation specific polymerase chain reaction assay determining the methylation status of GSTP1, APC and RASSF1 was strongly associated with repeat biopsy outcome up to 30 months after initial negative biopsy in men with suspicion of prostate cancer. Adding this epigenetic assay could improve the prostate cancer diagnostic process and decrease unnecessary repeat biopsies. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Creutzfeldt-Jakob disease: updated diagnostic criteria, treatment algorithm, and the utility of brain biopsy.

    Science.gov (United States)

    Manix, Marc; Kalakoti, Piyush; Henry, Miriam; Thakur, Jai; Menger, Richard; Guthikonda, Bharat; Nanda, Anil

    2015-11-01

    Creutzfeldt-Jakob disease (CJD) is a rare neurodegenerative condition with a rapid disease course and a mortality rate of 100%. Several forms of the disease have been described, and the most common is the sporadic type. The most challenging aspect of this disease is its diagnosis-the gold standard for definitive diagnosis is considered to be histopathological confirmation-but newer tests are providing means for an antemortem diagnosis in ways less invasive than brain biopsy. Imaging studies, electroencephalography, and biomarkers are used in conjunction with the clinical picture to try to make the diagnosis of CJD without brain tissue samples, and all of these are reviewed in this article. The current diagnostic criteria are limited; test sensitivity and specificity varies with the genetics of the disease as well as the clinical stage. Physicians may be unsure of all diagnostic testing available, and may order outdated tests or prematurely request a brain biopsy when the diagnostic workup is incomplete. The authors review CJD, discuss the role of brain biopsy in this patient population, provide a diagnostic pathway for the patient presenting with rapidly progressive dementia, and propose newer diagnostic criteria.

  20. Diagnostic Accuracy of Robot-Guided, Software Based Transperineal MRI/TRUS Fusion Biopsy of the Prostate in a High Risk Population of Previously Biopsy Negative Men

    Directory of Open Access Journals (Sweden)

    Malte Kroenig

    2016-01-01

    Full Text Available Objective. In this study, we compared prostate cancer detection rates between MRI-TRUS fusion targeted and systematic biopsies using a robot-guided, software based transperineal approach. Methods and Patients. 52 patients received a MRIT/TRUS fusion followed by a systematic volume adapted biopsy using the same robot-guided transperineal approach. The primary outcome was the detection rate of clinically significant disease (Gleason grade ≥ 4. Secondary outcomes were detection rate of all cancers, sampling efficiency and utility, and serious adverse event rate. Patients received no antibiotic prophylaxis. Results. From 52 patients, 519 targeted biopsies from 135 lesions and 1561 random biopsies were generated (total n=2080. Overall detection rate of clinically significant PCa was 44.2% (23/52 and 50.0% (26/52 for target and random biopsy, respectively. Sampling efficiency as the median number of cores needed to detect clinically significant prostate cancer was 9 for target (IQR: 6–14.0 and 32 (IQR: 24–32 for random biopsy. The utility as the number of additionally detected clinically significant PCa cases by either strategy was 0% (0/52 for target and 3.9% (2/52 for random biopsy. Conclusions. MRI/TRUS fusion based target biopsy did not show an advantage in the overall detection rate of clinically significant prostate cancer.

  1. Fluoroscopically guided automated gun biopsy of chest lesions: diagnostic accuracy and complications

    International Nuclear Information System (INIS)

    Oh, Hee Sul; Han, Young Min; Choi, Ki Chul and others

    1998-01-01

    To determine the diagnostic accuracy and frequency of complications of fluoroscopyguided transthoracic needle biopsy, using an automated gun biopsy system. We retrospectively reviewed 86 patients who underwent automated gun biopsy between October 1995 and October 1996. An 18-gauge cutting needle was used in all cases. All biopsies were performed under fluoroscopic guidance by one interventional radiologist. Tissue sufficient for histologic diagnosis was obtained in 73 of 86 biopsies(84.9%). Fifty-six lesions were malignent and 30 were benign. Sensitivity and diagnostic accuracy for malignant lesions were 87.5% and 87.5%, respectively while cell type specificity in malignant diagnosis was 91.7%(11/12). Sensitivity and diagnostic accuracy for benign lesions were 80.0% and 73.3%, respectively. Postbioptic pneumothorax occurred in three of 86 biopsies(3.5%), one of which required placement of a chest tube. Automated gun biopsy is a simple, safe method for the diagnosis of focal chest lesions. An automated biopsy device offers high diagnostic accuracy in casis involving malignant and benign lesions of the chest, and is particularly useful for determining malignant cell type and specific diagnosis of benign lesions.=20

  2. A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment.

    Science.gov (United States)

    Bruners, Philipp; Penzkofer, Tobias; Isfort, Peter; Pfeffer, Jochen; Schmitz-Rode, Thomas; Günther, Rolf W; Mahnken, Andreas H

    2010-08-01

    To develop a trucut biopsy needle featuring two electrodes that allow for bipolar radiofrequency (RF) coagulation of the puncture tract. We modified a 14-G trucut biopsy needle to contain two insulated electrodes and connected the device to an RF generator. Biopsies in ex vivo porcine liver and kidney were performed. The puncture tract was coagulated by using different RF energy settings (5 W, 10 W, 20 W). Tissue specimens were dissected along the puncture tract and the coagulation area was macroscopically evaluated. CT-guided in vivo liver and kidney biopsies were performed in two domestic pigs. Lengths of specimens were measured. Post-biopsy contrast-enhanced CT examinations were performed to rule out biopsy-related bleeding. Animals were euthanised and coagulation areas macroscopically explored. The mean diameters of the coagulated area around the ex vivo biopsy tract were 4.2 +/- 1.1 mm (5 W), 6.0 +/- 2.0 mm (10 W) and 5.2 +/- 0.51 mm (20 W) in liver and 5.0 +/- 0.7 mm (5 W), 6.6 +/- 0.9 (10 W) and 6.0 +/- 2.0 mm (20 W) in kidney. After biopsies CT revealed no bleeding. Mean maximum coagulation diameters were 10.1 +/- 4.6 mm (10 W) in liver and 6.0 +/- 2.5 mm (10 W) in kidney. Mean length of the specimens was 12.2 +/- 4.4 mm in kidney and 11.1 +/- 3.6 mm in liver tissue. Bipolar RF biopsy is a promising tool for tract coagulation after percutaneous biopsy.

  3. A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment

    International Nuclear Information System (INIS)

    Bruners, Philipp; Penzkofer, Tobias; Isfort, Peter; Pfeffer, Jochen; Schmitz-Rode, Thomas; Guenther, Rolf W.; Mahnken, Andreas H.

    2010-01-01

    To develop a trucut biopsy needle featuring two electrodes that allow for bipolar radiofrequency (RF) coagulation of the puncture tract. We modified a 14-G trucut biopsy needle to contain two insulated electrodes and connected the device to an RF generator. Biopsies in ex vivo porcine liver and kidney were performed. The puncture tract was coagulated by using different RF energy settings (5 W, 10 W, 20 W). Tissue specimens were dissected along the puncture tract and the coagulation area was macroscopically evaluated. CT-guided in vivo liver and kidney biopsies were performed in two domestic pigs. Lengths of specimens were measured. Post-biopsy contrast-enhanced CT examinations were performed to rule out biopsy-related bleeding. Animals were euthanised and coagulation areas macroscopically explored. The mean diameters of the coagulated area around the ex vivo biopsy tract were 4.2 ± 1.1 mm (5 W), 6.0 ± 2.0 mm (10 W) and 5.2 ± 0.51 mm (20 W) in liver and 5.0 ± 0.7 mm (5 W), 6.6 ± 0.9 (10 W) and 6.0 ± 2.0 mm (20 W) in kidney. After biopsies CT revealed no bleeding. Mean maximum coagulation diameters were 10.1 ± 4.6 mm (10 W) in liver and 6.0 ± 2.5 mm (10 W) in kidney. Mean length of the specimens was 12.2 ± 4.4 mm in kidney and 11.1 ± 3.6 mm in liver tissue. Bipolar RF biopsy is a promising tool for tract coagulation after percutaneous biopsy. (orig.)

  4. RAPID PROCESSING OF ARCHIVAL TISSUE SAMPLES FOR PROTEOMIC ANALYSIS USING PRESSURE-CYCLING TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Vinuth N. Puttamallesh1,2

    2017-06-01

    Full Text Available Advent of mass spectrometry based proteomics has revolutionized our ability to study proteins from biological specimen in a high-throughput manner. Unlike cell line based studies, biomedical research involving tissue specimen is often challenging due to limited sample availability. In addition, investigation of clinically relevant research questions often requires enormous amount of time for sample collection prospectively. Formalin fixed paraffin embedded (FFPE archived tissue samples are a rich source of tissue specimen for biomedical research. However, there are several challenges associated with analysing FFPE samples. Protein cross-linking and degradation of proteins particularly affects proteomic analysis. We demonstrate that barocycler that uses pressure-cycling technology enables efficient protein extraction and processing of small amounts of FFPE tissue samples for proteomic analysis. We identified 3,525 proteins from six 10µm esophageal squamous cell carcinoma (ESCC tissue sections. Barocycler allows efficient protein extraction and proteolytic digestion of proteins from FFPE tissue sections at par with conventional methods.

  5. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    Science.gov (United States)

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    high, prostate biopsies may not be needed for all men with elevated prostate-specific antigen values and nonsuspicious mpMRI. We present our technique to sample (biopsy) the prostate by the transperineal route (the area between the scrotum and the anus) to detect prostate cancer using a fusion of magnetic resonance and ultrasound images to guide the sampling. Copyright © 2016 European Association of Urology. All rights reserved.

  6. Systematic ultrasound-guided saturation and template biopsy of the prostate: indications and advantages of extended sampling.

    Science.gov (United States)

    Isbarn, Hendrik; Briganti, Alberto; De Visschere, Pieter J L; Fütterer, Jurgen J; Ghadjar, Pirus; Giannarini, Gianluca; Ost, Piet; Ploussard, Guillaume; Sooriakumaran, Prasanna; Surcel, Christian I; van Oort, Inge M; Yossepowitch, Ofer; van den Bergh, Roderick C N

    2015-04-01

    Prostate biopsy (PB) is the gold standard for the diagnosis of prostate cancer (PCa). However, the optimal number of biopsy cores remains debatable. We sought to compare contemporary standard (10-12 cores) vs. saturation (=18 cores) schemes on initial as well as repeat PB. A non-systematic review of the literature was performed from 2000 through 2013. Studies of highest evidence (randomized controlled trials, prospective non-randomized studies, and retrospective reports of high quality) comparing standard vs saturation schemes on initial and repeat PB were evaluated. Outcome measures were overall PCa detection rate, detection rate of insignificant PCa, and procedure-associated morbidity. On initial PB, there is growing evidence that a saturation scheme is associated with a higher PCa detection rate compared to a standard one in men with lower PSA levels (40 cc), or lower PSA density values (sampling is associated with a high rate of acute urinary retention, whereas other severe adverse events, such as sepsis, appear not to occur more frequently with saturation schemes. Current evidence suggests that saturation schemes are associated with a higher PCa detection rate compared to standard ones on initial PB in men with lower PSA levels or larger prostates, and on repeat PB. Since most data are derived from retrospective studies, other endpoints such as detection rate of insignificant disease - especially on repeat PB - show broad variations throughout the literature and must, thus, be interpreted with caution. Future prospective controlled trials should be conducted to compare extended templates with newer techniques, such as image-guided sampling, in order to optimize PCa diagnostic strategy.

  7. Gallium-67 imaging in patients with dilated cardiomyopathy and biopsy-proven myocarditis

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Henkin, R.E.; Robinson, J.A.; Subramanian, R.; Scanlon, P.J.; Gunnar, R.M.

    1984-01-01

    Current standards for detection of myocarditis in a clinical setting rely on endomyocardial biopsy for accurate diagnosis. With this technique a subset of patients with dilated cardiomyopathy show unsuspected myocarditis histologically. Endomyocardial biopsy, despite its specificity, may lack sensitivity due to sampling error if the inflammation is patchy or focal. Therefore, inflammation-sensitive radioisotopic imaging may be a useful adjunct in the diagnosis of myocarditis. This study was designed to evaluate the applicability of gallium-67 (67Ga) myocardial imaging as an adjunct to endomyocardial biopsy in the diagnosis of myocarditis. Sixty-eight consecutive patients referred for evaluation of dilated cardiomyopathy underwent 71 parallel studies with 67Ga imaging and biopsies that served as the basis of comparison for this study. Histologic myocarditis was identified in 8% of biopsy specimens. Clinical and hemodynamic parameters could not be used to predict the presence of myocarditis. Five of six biopsy samples (87%) with myocarditis showed dense 67Ga uptake, whereas only nine of 65 negative biopsy samples (14%) were paired with equivocally positive 67Ga scans. The single patient with myocarditis and no myocardial 67Ga uptake had dense mediastinal lymph node uptake that may have obscured cardiac uptake. The incidence of myocarditis on biopsy with a positive 67Ga scan was 36% (5/14); however, the incidence of myocarditis with a negative 67Ga scan was only 1.8% (1/57). Follow-up scans for three patients showed close correlation of 67Ga uptake with myocarditis on biopsy. In conclusion 67Ga may be a useful screening test for identifying patients with a high yield of myocarditis on biopsy, and serial scans may eliminate the need for frequent biopsies in patients with proven myocarditis

  8. Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Bigio, I.J.; Loree, T.R.; Mourant, J.; Shimada, T. [Los Alamos National Lab., NM (United States); Story-Held, K.; Glickman, R.D. [Texas Univ. Health Science Center, San Antonio, TX (United States). Dept. of Ophthalmology; Conn, R. [Lovelace Medical Center, Albuquerque, NM (United States). Dept. of Urology

    1993-08-01

    A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength dependent. Thus, morphology and size changes can be expected to cause significant changes in an optical signature that is derived from the wavelength dependence of elastic scattering. The data acquisition and storage/display time with the OBS instrument is {approximately}1 second. Thus, in addition to the reduced invasiveness of this technique compared with current state-of-the-art methods (surgical biopsy and pathology analysis), the OBS offers the possibility of impressively faster diagnostic assessment. The OBS employs a small fiber-optic probe that is amenable to use with any endoscope, catheter or hypodermic, or to direct surface examination (e.g. as in skin cancer or cervical cancer). It has been tested in vitro on animal and human tissue samples, and clinical testing in vivo is currently in progress.

  9. PET/CT-guided percutaneous biopsy of FDG-avid metastatic bone lesions in patients with advanced lung cancer: a safe and effective technique

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Wei; Hao, Bing; Chen, Hao-jun; Zhao, Long; Luo, Zuo-ming; Wu, Hua; Sun, Long [The First Affiliated Hospital of Xiamen University, Department of Nuclear Medicine and Minnan PET Center, Xiamen Cancer Hospital, Xiamen (China)

    2017-01-15

    {sup 18}F-FDG PET/CT should be performed before a diagnostic biopsy site is chosen in patients with a high clinical suspicion of aggressive, advanced tumour. The aim of this study was to evaluate the safety and efficacy of {sup 18}F-FDG PET/CT in guiding biopsy of bone metastases in patients with advanced lung cancer. PET/CT-guided percutaneous core biopsies were performed in 51 consecutive patients with suspected lung cancer and {sup 18}F-FDG-avid bone lesions after whole-body {sup 18}F-FDG PET/CT scans. Generally, one tissue sample was obtained from each patient. The final diagnoses were established on the basis of the histology results. The histopathological and molecular testing results were systematically evaluated. A total of 53 samples were obtained for histological examination or molecular testing as a second biopsy was required in two patients in whom the pathological diagnosis was unclear following the first biopsy. The pathological diagnosis and lung cancer classification were confirmed in 48 patients. The epidermal growth factor receptor mutation status was determined in 23 biopsies, and the mutation rate was 30.4 % (7/23). The anaplastic lymphoma kinase mutation status was determined in 19 biopsies, and the mutation rate was 31.6 % (6/19). Two of the 51 biopsies were positive for non-Hodgkin's lymphoma and one was positive for metastatic renal cell carcinoma. The first-time diagnostic success rate of biopsy was 96.1 % (49/51) and the overall diagnostic success rate and sensitivity were 100 %. All 51 patients were eventually confirmed as having stage IV disease. No serious complications were encountered and the average biopsy time was 30 min. PET/CT-guided percutaneous biopsy of {sup 18}F-FDG-avid bone metastases is an effective and safe method that yields a high diagnostic success rate in the evaluation of hypermetabolic bone lesions in patients with suspected advanced lung cancer. (orig.)

  10. Stereotactic biopsy aided by a computer graphics workstation: experience with 200 consecutive cases.

    Science.gov (United States)

    Ulm, A J; Bova, F J; Friedman, W A

    2001-12-01

    The advent of modern computer technology has made it possible to examine not just the target point, but the entire trajectory in planning for stereotactic biopsies. Two hundred consecutive biopsies were performed by one surgeon, utilizing a computer graphics workstation. The target point, entry point, and complete trajectory were carefully scrutinized and adjusted to minimize potential complications. Pathologically abnormal tissue was obtained in 197 cases (98.5%). There was no mortality in this series. Symptomatic hemorrhages occurred in 4 cases (2%). Computer graphics workstations facilitate safe and effective biopsies in virtually any brain area.

  11. Development and validation of a microRNA based diagnostic assay for primary tumor site classification of liver core biopsies

    DEFF Research Database (Denmark)

    Perell, Katharina; Vincent, Martin; Vainer, Ben

    2015-01-01

    for normal liver tissue contamination. Performance was estimated by cross-validation, followed by independent validation on 55 liver core biopsies with a tumor content as low as 10%. A microRNA classifier developed, using the statistical contamination model, showed an overall classification accuracy of 74...... on classification. MicroRNA profiling was performed using quantitative Real-Time PCR on formalin-fixed paraffin-embedded samples. 278 primary tumors and liver metastases, representing nine primary tumor classes, as well as normal liver samples were used as a training set. A statistical model was applied to adjust.......5% upon independent validation. Two-thirds of the samples were classified with high-confidence, with an accuracy of 92% on high-confidence predictions. A classifier trained without adjusting for liver tissue contamination, showed a classification accuracy of 38.2%. Our results indicate that surrounding...

  12. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  13. A high precision method for quantitative measurements of reactive oxygen species in frozen biopsies.

    Directory of Open Access Journals (Sweden)

    Kirsti Berg

    Full Text Available OBJECTIVE: An electron paramagnetic resonance (EPR technique using the spin probe cyclic hydroxylamine 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine (CMH was introduced as a versatile method for high precision quantification of reactive oxygen species, including the superoxide radical in frozen biological samples such as cell suspensions, blood or biopsies. MATERIALS AND METHODS: Loss of measurement precision and accuracy due to variations in sample size and shape were minimized by assembling the sample in a well-defined volume. Measurement was carried out at low temperature (150 K using a nitrogen flow Dewar. The signal intensity was measured from the EPR 1st derivative amplitude, and related to a sample, 3-carboxy-proxyl (CP• with known spin concentration. RESULTS: The absolute spin concentration could be quantified with a precision and accuracy better than ±10 µM (k = 1. The spin concentration of samples stored at -80°C could be reproduced after 6 months of storage well within the same error estimate. CONCLUSION: The absolute spin concentration in wet biological samples such as biopsies, water solutions and cell cultures could be quantified with higher precision and accuracy than normally achievable using common techniques such as flat cells, tissue cells and various capillary tubes. In addition; biological samples could be collected and stored for future incubation with spin probe, and also further stored up to at least six months before EPR analysis, without loss of signal intensity. This opens for the possibility to store and transport incubated biological samples with known accuracy of the spin concentration over time.

  14. Confocal fluorescence microscopy for rapid evaluation of invasive tumor cellularity of inflammatory breast carcinoma core needle biopsies.

    Science.gov (United States)

    Dobbs, Jessica; Krishnamurthy, Savitri; Kyrish, Matthew; Benveniste, Ana Paula; Yang, Wei; Richards-Kortum, Rebecca

    2015-01-01

    Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.

  15. An investigation of the microbiota in uterine flush samples and endometrial biopsies from dairy cows during the first 7 weeks postpartum

    DEFF Research Database (Denmark)

    Knudsen, Lif Rødtness Vesterby; Karstrup, Cecilia Christensen; Pedersen, Hanne Gervi

    2016-01-01

    Metritis and endometritis commonly occur in dairy cows after calving. Although numerous studies have been performed to identify the causative pathogens, a complete overview has not been done. Metagenomic studies have analyzed the bacterial populations of uterine flush samples from postpartum (pp......% and 13%, respectively, of the bacterial populations in the flush samples. The Mycoplasmataceae family was observed in much higher quantity in the flush samples than in the biopsies of the endometritis groups at weeks 4 and 7. Our findings support the observations of previous metagenomic studies...

  16. Ga-68 DOTATOC PET/CT-Guided Biopsy and Cryoablation with Autoradiography of Biopsy Specimen for Treatment of Tumor-Induced Osteomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Memorial Sloan Kettering Cancer Center, Interventional Radiology Service (United States); Grewal, Ravinder K. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopedic Surgical Oncology Service, Department of Surgery (United States); Antonescu, Cristina R. [Memorial Sloan Kettering Cancer Center, Department of Pathology (United States); Fanchon, Louise [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology (United States); Carrasquillo, Jorge A. [Memorial Sloan Kettering Cancer Center, Molecular Imaging and Therapy Service, Department of Radiology (United States); Kirov, Assen [Memorial Sloan Kettering Cancer Center, Department of Physics (United States); Farooki, Azeez [Memorial Sloan Kettering Cancer Center, Department of Medicine (United States)

    2016-09-15

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome caused by small benign tumors of mesenchymal origin also known as phosphaturic mesenchymal tumors mixed connective tissue variant. Excellent prognosis is expected with eradication of the culprit tumor. These small tumors are notoriously difficult to localize with conventional imaging studies; this often leads to an extensive work up and prolonged morbidity. We report a patient with clinical diagnosis of TIO whose culprit tumor was localized with Ga-68 DOTATOC PET/CT and MRI. Biopsy and cryoablation were performed under Ga-68 DOTATOC PET/CT guidance. Autoradiography of the biopsy specimen was performed and showed in situ correlation between Ga-68 DOTATOC uptake and histopathology with millimeter resolution.

  17. Concentration of folate in colorectal tissue biopsies predicts prevalence of adenomatous polyps

    Science.gov (United States)

    Background and aims: Folate has been implicated as a potential aetiological factor for colorectal cancer. Previous research has not adequately exploited concentrations of folate in normal colonic mucosal biopsies to examine the issue. Methods: Logistic regression models were used to estimate ORs ...

  18. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  19. Analysis of chemical components from plant tissue samples

    Science.gov (United States)

    Laseter, J. L.

    1972-01-01

    Information is given on the type and concentration of sterols, free fatty acids, and total fatty acids in plant tissue samples. All samples were analyzed by gas chromatography and then by gas chromatography-mass spectrometry combination. In each case the mass spectral data was accumulated as a computer printout and plot. Typical gas chromatograms are included as well as tables describing test results.

  20. Digital quantification of fibrosis in liver biopsy sections: description of a new method by Photoshop software.

    Science.gov (United States)

    Dahab, Gamal M; Kheriza, Mohamed M; El-Beltagi, Hussien M; Fouda, Abdel-Motaal M; El-Din, Osama A Sharaf

    2004-01-01

    The precise quantification of fibrous tissue in liver biopsy sections is extremely important in the classification, diagnosis and grading of chronic liver disease, as well as in evaluating the response to antifibrotic therapy. Because the recently described methods of digital image analysis of fibrosis in liver biopsy sections have major flaws, including the use of out-dated techniques in image processing, inadequate precision and inability to detect and quantify perisinusoidal fibrosis, we developed a new technique in computerized image analysis of liver biopsy sections based on Adobe Photoshop software. We prepared an experimental model of liver fibrosis involving treatment of rats with oral CCl4 for 6 weeks. After staining liver sections with Masson's trichrome, a series of computer operations were performed including (i) reconstitution of seamless widefield images from a number of acquired fields of liver sections; (ii) image size and solution adjustment; (iii) color correction; (iv) digital selection of a specified color range representing all fibrous tissue in the image and; (v) extraction and calculation. This technique is fully computerized with no manual interference at any step, and thus could be very reliable for objectively quantifying any pattern of fibrosis in liver biopsy sections and in assessing the response to antifibrotic therapy. It could also be a valuable tool in the precise assessment of antifibrotic therapy to other tissue regardless of the pattern of tissue or fibrosis.

  1. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    International Nuclear Information System (INIS)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M.

    2001-01-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  2. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    Energy Technology Data Exchange (ETDEWEB)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M. [St. Thomas-Elgin General Hospital, St. Thomas, Ontario (Canada)

    2001-02-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  3. Optimized high-throughput microRNA expression profiling provides novel biomarker assessment of clinical prostate and breast cancer biopsies

    Directory of Open Access Journals (Sweden)

    Fedele Vita

    2006-06-01

    Full Text Available Abstract Background Recent studies indicate that microRNAs (miRNAs are mechanistically involved in the development of various human malignancies, suggesting that they represent a promising new class of cancer biomarkers. However, previously reported methods for measuring miRNA expression consume large amounts of tissue, prohibiting high-throughput miRNA profiling from typically small clinical samples such as excision or core needle biopsies of breast or prostate cancer. Here we describe a novel combination of linear amplification and labeling of miRNA for highly sensitive expression microarray profiling requiring only picogram quantities of purified microRNA. Results Comparison of microarray and qRT-PCR measured miRNA levels from two different prostate cancer cell lines showed concordance between the two platforms (Pearson correlation R2 = 0.81; and extension of the amplification, labeling and microarray platform was successfully demonstrated using clinical core and excision biopsy samples from breast and prostate cancer patients. Unsupervised clustering analysis of the prostate biopsy microarrays separated advanced and metastatic prostate cancers from pooled normal prostatic samples and from a non-malignant precursor lesion. Unsupervised clustering of the breast cancer microarrays significantly distinguished ErbB2-positive/ER-negative, ErbB2-positive/ER-positive, and ErbB2-negative/ER-positive breast cancer phenotypes (Fisher exact test, p = 0.03; as well, supervised analysis of these microarray profiles identified distinct miRNA subsets distinguishing ErbB2-positive from ErbB2-negative and ER-positive from ER-negative breast cancers, independent of other clinically important parameters (patient age; tumor size, node status and proliferation index. Conclusion In sum, these findings demonstrate that optimized high-throughput microRNA expression profiling offers novel biomarker identification from typically small clinical samples such as breast

  4. Molecular diagnosis of rhino-orbito-cerebral mucormycosis from fresh tissue samples.

    Science.gov (United States)

    Zaman, Kamran; Rudramurthy, Shivaprakash Mandya; Das, Ashim; Panda, Naresh; Honnavar, Prasanna; Kaur, Harsimran; Chakrabarti, Arunaloke

    2017-08-01

    We aimed to evaluate a PCR-based technique for the diagnosis of mucormycosis and the identification of fungi from fresh tissue specimens in patients with rhino-orbito-cerebral-mucormycosis (ROCM). Fifty cases of ROCM were included in the study. Conventional identification was performed using microscopy and culture. Molecular diagnosis was performed by amplifying the ribosomal DNA using pan-fungal ITS primers and semi-nested Mucorales-specific primers of the 18S region. The amplified products were sequenced to identify the agents. The utility of PCR-RFLP of the 18S region of rDNA was evaluated to identify the Mucorales. The ROCM cases were diagnosed by the demonstration of aseptate ribbon-like hyphae in biopsy specimens collected from the patients. Isolation was possible in 24 (48 %) samples. The ITS2 PCR confirmed mucormycosis in 27 cases (54 %; CI 59.4-68.2). By comparison, Mucorales-specific PCR was able to amplify DNA and the sequence enabled the identification of Mucorales speciesin all the patients. PCR-RFLP of the 18S region of rDNA could only identify the agent to genus level. The molecular technique was able to identify Mucorales species in 26 (42 %) cases that were negative by culture. Mucorales-specific semi-nested PCR targeting the 18S region is a better technique than ITS2 PCR for diagnosis. PCR-RFLP of the 18S region helps in identification to genus level.

  5. Towards real-time metabolic profiling of a biopsy specimen during a surgical operation by 1H high resolution magic angle spinning nuclear magnetic resonance: a case report

    Directory of Open Access Journals (Sweden)

    Piotto Martial

    2012-01-01

    Full Text Available Abstract Introduction Providing information on cancerous tissue samples during a surgical operation can help surgeons delineate the limits of a tumoral invasion more reliably. Here, we describe the use of metabolic profiling of a colon biopsy specimen by high resolution magic angle spinning nuclear magnetic resonance spectroscopy to evaluate tumoral invasion during a simulated surgical operation. Case presentation Biopsy specimens (n = 9 originating from the excised right colon of a 66-year-old Caucasian women with an adenocarcinoma were automatically analyzed using a previously built statistical model. Conclusions Metabolic profiling results were in full agreement with those of a histopathological analysis. The time-response of the technique is sufficiently fast for it to be used effectively during a real operation (17 min/sample. Metabolic profiling has the potential to become a method to rapidly characterize cancerous biopsies in the operation theater.

  6. Assessment of tissue fibrosis in skin biopsies from patients with systemic sclerosis employing confocal laser scanning microscopy: an objective outcome measure for clinical trials?

    Science.gov (United States)

    Busquets, Joanna; Del Galdo, Francesco; Kissin, Eugene Y.

    2010-01-01

    Objectives. To obtain an objective, unbiased assessment of skin fibrosis in patients with SSc for use in clinical trials of SSc disease-modifying therapeutics. Methods. Skin biopsies from the dorsal forearm of six patients with diffuse SSc and six healthy controls, and skin biopsies from the forearm of one patient with diffuse SSc before and following 1 year treatment with mycophenolate mofetil were analysed by confocal laser scanning microscopy (CLSM) with specific antibodies against collagen types I and III or fibronectin. The integrated density of fluorescence (IDF) was calculated employing National Institutes of Health-ImageJ software in at least four different fields per biopsy spanning the full dermal thickness. Results. The intensities of collagen types I and III and fibronectin IDF were 174, 147 and 139% higher in SSc skin than in normal skin, respectively. All differences were statistically significant. The sum of the IDF values obtained for the three proteins yielded a comprehensive fibrosis score. The average fibrosis score for the six SSc samples was 28.3 × 106 compared with 18.6 × 106 for the six normal skin samples (P < 0.0001). Comparison of skin biopsies obtained from the same SSc patient before treatment and after 12 months of treatment with mycophenolate mofetil showed a reduction of 39% in total fibrosis score after treatment. Conclusions. CLSM followed by quantitative image analysis provides an objective and unbiased assessment of skin fibrosis in SSc and could be a useful end-point for clinical trials with disease-modifying agents to monitor the response or progression of the disease. PMID:20202926

  7. CT-guided biopsy: diagnostic relevance, therapeutic consequences and economic aspects

    International Nuclear Information System (INIS)

    Schwarzenberg, H.; Mueller-Huelsbeck, S.; Link, J.; Brossmann, J.; Fahl, M.; Quirin, A.; Heller, M.

    1996-01-01

    Purpose: To evaluate the diagnostic and clinical relevance and therapeutic consequences of CT-guided biopsy with regard to economic aspects. Methods: 213 CT-guided biopsies in 190 were evaluated. All information regarding patient referral, reason for request, body region, underlying diagnosis, and clinical consequences were registered over a period of 22.2±9.4 month. Results: Patient referral to biopsy was mainly from the departments of surgery, internal medicine, and radiotherapy with the question of tumor and metastasis. Less than 5% of biopsies were performed in outpatients. Main regions were the lung (39%), the abdomen (35%), and the skeleton (11%). Biopsy and surgical histology corresponded in 73%. Largest diagnosis groups were benign unspecific tissues or other benign lesions in 24%. As a result of CTP no further procedures necessary in 22.5%. Follow-up studies or conservative treatment were indicated in 11.3%. Surgical procedures were needed in only 15.5%. There was only one complication requiring therapy. Conclusion: CT-guided biopsy is a safe procedure, which helps to avoid unnecessary cost-intensive diagnostics and surgical treatment. If CTP is performed early and in outpatients residence time in the hospital is reduced and thus money is saved. (orig.) [de

  8. Usefulness of the coaxial technique in US-guided breast core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok [Dongkang general hospital, Seoul (Korea, Republic of); Ham, Soo Youn [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-05-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells.

  9. Usefulness of the coaxial technique in US-guided breast core biopsy

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok; Ham, Soo Youn

    1999-01-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells

  10. Testicular Biopsy for Fertility Preservation in Prepubertal Boys with Cancer: Identifying Preferences for Procedure and Reactions to Disclosure Practices.

    Science.gov (United States)

    Gupta, Abha A; Donen, Rachel M; Sung, Lillian; Boydell, Katherine M; Lo, Kirk C; Stephens, Derek; Pritchard, Sheila; Portwine, Carol; Maloney, Anne Marie; Lorenzo, Armando J

    2016-07-01

    Fertility preservation options are limited in prepubertal boys with cancer. Worldwide there has been growing interest in testicular tissue cryopreservation as a promising experimental strategy to address future infertility. We measured and compared parent, male cancer survivor and provider willingness to accept the risk of testicular biopsy among prepubertal boys with cancer, and identified reactions to disclosure practices. We conducted a multicenter study that included 153 parents of prepubertal boys with cancer, 77 male survivors of childhood cancer and 30 oncology providers. The threshold technique was used to measure subject relative willingness to accept risk of testicular biopsy under 4 different aspects of care, ie chance of infertility, complications from biopsy, development of technology to use tissue and tissue storage cost. A total of 47 in-depth interviews were conducted to identify reactions to disclosure practices. A total of 52 survivors (67%), 22 providers (73%) and 110 parents (72%) selected to have testicular biopsy (vs no biopsy). Median minimum infertility risk to make biopsy worthwhile varied from 25% to 30% among the 3 respondent groups. Interviews revealed that some providers would not offer biopsy in cases of greater perceived risk than benefit, that parents preferred having information regardless of risk of infertility and that nondisclosure elicited adverse feelings from some parents. Parents, survivors and providers were willing to accept risk of prepubertal testicular biopsy. Parental/survivor desire for information and provider decision not to disclose suggest that barriers to information delivery need to be addressed. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Parotid Gland Biopsy, the Alternative Way to Diagnose Sjogren Syndrome

    NARCIS (Netherlands)

    Spijkervet, Fred. K.L.; Haacke, Erlin; Kroese, Frans G. M.; Bootsma, Hendrika; Vissink, Arjan

    Salivary gland biopsy is a technique broadly applied for the diagnosis of Sjogren syndrome (SS), lymphoma in SS, and connective tissue disorders (sarcoidosis, amyloidosis). In SS characteristic histology findings are found, including lymphocytic infiltration surrounding the excretory ducts in

  12. GeLC-MS: A Sample Preparation Method for Proteomics Analysis of Minimal Amount of Tissue.

    Science.gov (United States)

    Makridakis, Manousos; Vlahou, Antonia

    2017-10-10

    Application of various proteomics methodologies have been implemented for the global and targeted proteome analysis of many different types of biological samples such as tissue, urine, plasma, serum, blood, and cell lines. Among the aforementioned biological samples, tissue has an exceptional role into clinical research and practice. Disease initiation and progression is usually located at the tissue level of different organs, making the analysis of this material very important for the understanding of the disease pathophysiology. Despite the significant advances in the mass spectrometry instrumentation, tissue proteomics still faces several challenges mainly due to increased sample complexity and heterogeneity. However, the most prominent challenge is attributed to the invasive procedure of tissue sampling which restricts the availability of fresh frozen tissue to minimal amounts and limited number of samples. Application of GeLC-MS sample preparation protocol for tissue proteomics analysis can greatly facilitate making up for these difficulties. In this chapter, a step by step guide for the proteomics analysis of minute amounts of tissue samples using the GeLC-MS sample preparation protocol, as applied by our group in the analysis of multiple different types of tissues (vessels, kidney, bladder, prostate, heart) is provided.

  13. CT-guided needle biopsy in the diagnosis of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue: a rare combination.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Wan, Chun; Shen, Yongchun; Wen, Fuqiang

    2015-01-01

    We represent a rare case of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue (MALT). The patient was a 66-year-old male presented with 1 month history of recurrent cough and hemoptysis. Chest CT showed solitary ground-glass opacity (GGO) in the upper lobe of the right lung and mediastinal lymph node enlargement in station 3p. A CT-guided transthoracic needle biopsy was performed. Tissue specimens of the GGO revealed a typical adenocarcinoma. Histopathologic diagnosis of mediastinal lymph node was extranodal marginal zone lymphoma of MALT. Because of its rarity, extranodal marginal zone lymphoma of MALT should be considered in the differential diagnosis when we encounter mediastinal lymphadenopathy in patients with lung adenocarcinoma.

  14. Efficacy of deep biopsy for subepithelial lesions in the upper gastrointestinal tract.

    Science.gov (United States)

    Vaicekauskas, Rolandas; Stanaitis, Juozas; Valantinas, Jonas

    2016-01-01

    Accurate diagnosis of subepithelial lesions (SELs) in the gastrointestinal tract depends on a variety of methods: endoscopy, endoscopic ultrasound and different types of biopsy. Making an error-free diagnosis is vital for the subsequent application of an appropriate treatment. To evaluate the efficacy of deep biopsy via the endoscopic submucosal dissection (ESD) technique for SELs in the upper gastrointestinal tract. It was a case series study. Deep biopsy via the ESD technique was completed in 38 patients between November 2012 and October 2014. Thirty-eight SELs in the upper gastrointestinal tract of varying size (very small ≤ 1 cm, small 1-2 cm and large ≥ 2 cm) by means of the ESD technique after an incision with an electrosurgical knife of the overlying layers and revealing a small part of the lesion were biopsied under direct endoscopic view. Deep biopsy via the ESD technique was diagnostic in 28 of 38 patients (73.3%; 95% CI: 59.7-89.7%). The diagnostic yield for SELs with a clear endophytic shape increased to 91.3%. An evident endophytic appearance of a subepithelial lesion, the mean number of biopsied samples (6.65 ±1.36) and the total size in length of all samples per case (19.88 ±8.07 mm) were the main criteria influencing the positiveness of deep biopsy in the diagnostic group compared to the nondiagnostic one (p = 0.001; p = 0.025; p = 0.008). Deep biopsy via the ESD technique is an effective and safe method for the diagnosis of SELs especially with a clear endophytic appearance in a large number of biopsied samples.

  15. Tissue-engineered human bioartificial muscles expressing a foreign recombinant protein for gene therapy

    Science.gov (United States)

    Powell, C.; Shansky, J.; Del Tatto, M.; Forman, D. E.; Hennessey, J.; Sullivan, K.; Zielinski, B. A.; Vandenburgh, H. H.

    1999-01-01

    Murine skeletal muscle cells transduced with foreign genes and tissue engineered in vitro into bioartificial muscles (BAMs) are capable of long-term delivery of soluble growth factors when implanted into syngeneic mice (Vandenburgh et al., 1996b). With the goal of developing a therapeutic cell-based protein delivery system for humans, similar genetic tissue-engineering techniques were designed for human skeletal muscle stem cells. Stem cell myoblasts were isolated, cloned, and expanded in vitro from biopsied healthy adult (mean age, 42 +/- 2 years), and elderly congestive heart failure patient (mean age, 76 +/- 1 years) skeletal muscle. Total cell yield varied widely between biopsies (50 to 672 per 100 mg of tissue, N = 10), but was not significantly different between the two patient groups. Percent myoblasts per biopsy (73 +/- 6%), number of myoblast doublings prior to senescence in vitro (37 +/- 2), and myoblast doubling time (27 +/- 1 hr) were also not significantly different between the two patient groups. Fusion kinetics of the myoblasts were similar for the two groups after 20-22 doublings (74 +/- 2% myoblast fusion) when the biopsy samples had been expanded to 1 to 2 billion muscle cells, a number acceptable for human gene therapy use. The myoblasts from the two groups could be equally transduced ex vivo with replication-deficient retroviral expression vectors to secrete 0.5 to 2 microg of a foreign protein (recombinant human growth hormone, rhGH)/10(6) cells/day, and tissue engineered into human BAMs containing parallel arrays of differentiated, postmitotic myofibers. This work suggests that autologous human skeletal myoblasts from a potential patient population can be isolated, genetically modified to secrete foreign proteins, and tissue engineered into implantable living protein secretory devices for therapeutic use.

  16. Multi-elemental imaging of paraffin-embedded human samples by laser-induced breakdown spectroscopy

    Science.gov (United States)

    Moncayo, S.; Trichard, F.; Busser, B.; Sabatier-Vincent, M.; Pelascini, F.; Pinel, N.; Templier, I.; Charles, J.; Sancey, L.; Motto-Ros, V.

    2017-07-01

    Chemical elements play central roles for physiological homeostasis in human cells, and their dysregulation might lead to a certain number of pathologies. Novel imaging techniques that improve the work of pathologists for tissue analysis and diagnostics are continuously sought. We report the use of Laser-Induced Breakdown Spectroscopy (LIBS) to perform multi-elemental images of human paraffin-embedded skin samples on the entire biopsy scale in a complementary and compatible way with microscope histopathological examination. A specific instrumental configuration is proposed in order to detect most of the elements of medical interest (i.e. P, Al, Mg, Na, Zn, Si, Fe, and Cu). As an example of medical application, we selected and analysed skin biopsies, including healthy skin tissue, cutaneous metastasis of melanoma, Merkel-cell carcinoma and squamous cell carcinoma. Clear distinctions in the distribution of chemical elements are observed from the different samples investigated. This study demonstrates the high complementarity of LIBS elemental imaging with conventional histopathology, opening new opportunities for any medical application involving metals.

  17. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  18. Effects of Re-heating Tissue Samples to Core Body Temperature on High-Velocity Ballistic Projectile-tissue Interactions.

    Science.gov (United States)

    Humphrey, Caitlin; Henneberg, Maciej; Wachsberger, Christian; Maiden, Nicholas; Kumaratilake, Jaliya

    2017-11-01

    Damage produced by high-speed projectiles on organic tissue will depend on the physical properties of the tissues. Conditioning organic tissue samples to human core body temperature (37°C) prior to conducting ballistic experiments enables their behavior to closely mimic that of living tissues. To minimize autolytic changes after death, the tissues are refrigerated soon after their removal from the body and re-heated to 37°C prior to testing. This research investigates whether heating 50-mm-cube samples of porcine liver, kidney, and heart to 37°C for varying durations (maximum 7 h) can affect the penetration response of a high-speed, steel sphere projectile. Longer conditioning times for heart and liver resulted in a slight loss of velocity/energy of the projectile, but the reverse effect occurred for the kidney. Possible reasons for these trends include autolytic changes causing softening (heart and liver) and dehydration causing an increase in density (kidney). © 2017 American Academy of Forensic Sciences.

  19. Imaging regional variation of cellular proliferation in gliomas using 3'-deoxy-3'-[18F]fluorothymidine positron-emission tomography: an image-guided biopsy study

    International Nuclear Information System (INIS)

    Price, S.J.; Fryer, T.D.; Cleij, M.C.; Dean, A.F.; Joseph, J.; Salvador, R.; Wang, D.D.; Hutchinson, P.J.; Clark, J.C.; Burnet, N.G.; Pickard, J.D.; Aigbirhio, F.I.

    2009-01-01

    Aim: To compare regional variations in uptake of 3'-deoxy-3'- [ 18 F]-fluorothymidine (FLT) images using positron-emission tomography (PET) with measures of cellular proliferation from biopsy specimens obtained by image-guided brain biopsies. Materials and methods: Fourteen patients with a supratentorial glioma that required an image-guided brain biopsy were imaged preoperatively with dynamic PET after the administration of FLT. Maps of FLT irreversible uptake rate (K i ) and standardized uptake value (SUV) were calculated. These maps were co-registered to a gadolinium-enhanced T1-weighted spoiled gradient echo (SPGR) sequence that was used for biopsy guidance, and the mean and maximum K i and SUV determined for each biopsy site. These values were correlated with the MIB-1 labelling index (a tissue marker of proliferation) from these biopsy sites. Results: A total of 57 biopsy sites were studied. Although all measures correlated with MIB-1 labelling index, K i max provided the best correlation (Pearson coefficient, r = 0.68; p i mean (±SD) was significantly higher than in normal tissue (3.3 ± 1.7 x 10 -3 ml plasma /min/ml tissue versus 1.2 ± 0.7 x 10 -3 ml plasma /min/ml tissue ; p = 0.001). High-grade gliomas showed heterogeneous uptake with a mean K i of 7.7 ± 4 x 10 -3 ml plasma /min/ml tissue . A threshold K i mean of 1.8 x 10 -3 differentiates between normal tissue and tumour (sensitivity 84%, specificity 88%); however, the latter threshold underestimated the extent of tumour in half the cases. SUV closely agreed with K i measurements. Conclusion: FLT PET is a useful marker of cellular proliferation that correlates with regional variation in cellular proliferation; however, it is unable to identify the margin of gliomas

  20. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  1. Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Braak, Sicco J., E-mail: sjbraak@gmail.com [St. Antonius Hospital, Department of Radiology (Netherlands); Herder, Gerarda J. M., E-mail: j.herder@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Pulmonology (Netherlands); Heesewijk, Johannes P. M. van, E-mail: j.heesewijk@antoniusziekenhuis.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Radiology (Netherlands)

    2012-12-15

    Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24-85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose-area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0-93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1-7). Mean fluoroscopy time was 161 (range 104-551) s, room time was 34 (range 15-79) min, mean DAP value was 25.9 (range 3.9-80.5) Gy{center_dot}cm{sup -2}, and interventional time was 18 (range 5-65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86-96), 100% (95% CI 82-100), 100% (95% CI 96-100), 66.7% (95% CI 55-83), and 91.7% (95% CI 86-96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

  2. Tissue and serum samples of patients with papillary thyroid cancer with and without benign background demonstrate different altered expression of proteins

    Directory of Open Access Journals (Sweden)

    Mardiaty Iryani Abdullah

    2016-09-01

    Full Text Available Background Papillary thyroid cancer (PTC is mainly diagnosed using fine-needle aspiration biopsy. This most common form of well-differentiated thyroid cancer occurs with or without a background of benign thyroid goiter (BTG. Methods In the present study, a gel-based proteomics analysis was performed to analyse the expression of proteins in tissue and serum samples of PTC patients with (PTCb; n = 6 and without a history of BTG (PTCa; n = 8 relative to patients with BTG (n = 20. This was followed by confirmation of the levels of proteins which showed significant altered abundances of more than two-fold difference (p < 0.01 in the tissue and serum samples of the same subjects using ELISA. Results The data of our study showed that PTCa and PTCb distinguish themselves from BTG in the types of tissue and serum proteins of altered abundance. While higher levels of alpha-1 antitrypsin (A1AT and heat shock 70 kDa protein were associated with PTCa, lower levels of A1AT, protein disulfide isomerase and ubiquitin-conjugating enzyme E2 N seemed apparent in the PTCb. In case of the serum proteins, higher abundances of A1AT and alpha 1-beta glycoprotein were detected in PTCa, while PTCb was associated with enhanced apolipoprotein A-IV and alpha 2-HS glycoprotein (AHSG. The different altered expression of tissue and serum A1AT as well as serum AHSG between PTCa and PTCb patients were also validated by ELISA. Discussion The distinctive altered abundances of the tissue and serum proteins form preliminary indications that PTCa and PTCb are two distinct cancers of the thyroid that are etiologically and mechanistically different although it is currently not possible to rule out that they may also be due other reasons such as the different stages of the malignant disease. These proteins stand to have a potential use as tissue or serum biomarkers to discriminate the three different thyroid neoplasms although this requires further validation in clinically

  3. Evaluation of The Value of Core Needle Biopsy in The Diagnosis of a Breast Mass

    Directory of Open Access Journals (Sweden)

    Asieh Sadat Fattahi

    2016-06-01

    Full Text Available Background: Core needle biopsy (CNB with histological findings is regarded as one of the most important diagnostic measures that make preoperative assessment and planning for appropriate treatment possible. The aim of this study was to determine the sensitivity and specificity of core biopsy results in our patients with benign and malignant breast lumps, especially for borderline breast lesions, by using a classification method.Methods: In this study, 116 patients who were referred to the Surgery Clinic of Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran with breast lump and underwent diagnostic procedures such as mammography and ultrasound were selected. Core needle biopsy (Tru-cut #14 or 16 was performed. After that, excisional biopsy was done. The benign, malignant and unspecified samples obtained by core needle biopsy were evaluated with the samples of the surgical and pathological findings. Then, false positive, false negative, sensitivity, specificity, and diagnostic accuracy of the core needle biopsy method were calculated. Also, the National Health Service Breast Screening Program (NHSBSP classification was employed.Results: The mean age of the participants in this study was 39±13.13 years and the mean tumor size was 2.7 cm. An average of 3.35 biopsies was taken from all patients. Most of the pathology samples taken from CNB and excisional biopsy were compatible with invasive ductal carcinoma. Of the B type classifications, B5 was the most frequent in both methods. Borderline lesions B3 and B4 had a change in their category after surgery. About 2.5% of the samples in core biopsy were inadequate. Skin bruising was the most common core biopsy complication reported. While, the most common complication of excisional biopsy was hematoma. Accuracy, sensitivity, specificity, positive and negative predictive values of the core needle biopsy procedure compared with excisional biopsy was 95.5%, 92.6%, 100%, 100%, and 91

  4. Preservation and rapid purification of DNA from decomposing human tissue samples.

    Science.gov (United States)

    Sorensen, Amy; Rahman, Elizabeth; Canela, Cassandra; Gangitano, David; Hughes-Stamm, Sheree

    2016-11-01

    One of the key features to be considered in a mass disaster is victim identification. However, the recovery and identification of human remains are sometimes complicated by harsh environmental conditions, limited facilities, loss of electricity and lack of refrigeration. If human remains cannot be collected, stored, or identified immediately, bodies decompose and DNA degrades making genotyping more difficult and ultimately decreasing DNA profiling success. In order to prevent further DNA damage and degradation after collection, tissue preservatives may be used. The goal of this study was to evaluate three customized (modified TENT, DESS, LST) and two commercial DNA preservatives (RNAlater and DNAgard ® ) on fresh and decomposed human skin and muscle samples stored in hot (35°C) and humid (60-70% relative humidity) conditions for up to three months. Skin and muscle samples were harvested from the thigh of three human cadavers placed outdoors for up to two weeks. In addition, the possibility of purifying DNA directly from the preservative solutions ("free DNA") was investigated in order to eliminate lengthy tissue digestion processes and increase throughput. The efficiency of each preservative was evaluated based on the quantity of DNA recovered from both the "free DNA" in solution and the tissue sample itself in conjunction with the quality and completeness of downstream STR profiles. As expected, DNA quantity and STR success decreased with time of decomposition. However, a marked decrease in DNA quantity and STR quality was observed in all samples after the bodies entered the bloat stage (approximately six days of decomposition in this study). Similar amounts of DNA were retrieved from skin and muscle samples over time, but slightly more complete STR profiles were obtained from muscle tissue. Although higher amounts of DNA were recovered from tissue samples than from the surrounding preservative, the average number of reportable alleles from the "free DNA" was

  5. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  6. Circumferential scouting punch biopsies to delineate surgical margin for dermatofibrosarcoma protuberans

    Directory of Open Access Journals (Sweden)

    Tsung-Mao Huang

    2012-03-01

    Full Text Available Dermatofibrosarcoma protuberans (DFSP is an uncommon soft-tissue tumor involving the dermis and subcutaneous tissue with a high local recurrence rate after standard excision. Mohs micrographic surgery offers a lower recurrence rate. However, the procedure requires multiple stages of excision with intraoperative histopathological mapping, which is time consuming and expensive. We report our experience of using circumferential scouting punch biopsy technique in five patients to determine in advance the resection margins for DFSP prior to wide excision. Multiple 4 mm punches, usually eight in number, were performed 1–2.5 cm around the palpable borders of DFSP to delineate the resection margins in five consecutive patients. Tumors were excised at a later date along the margin defined by these biopsies and the wounds were repaired with skin graft. The operation was completed in 2 hours in all cases excluding one that required frozen sections for deep margin. No recurrence was noted 2–10 years after the operations. The results suggest that circumferential scouting punch biopsies before wide excision may be an alternative method to define the resection margins for DFSP when Mohs surgery is not available.

  7. A method to estimate the fractional fat volume within a ROI of a breast biopsy for WAXS applications: Animal tissue evaluation

    International Nuclear Information System (INIS)

    Tang, Robert Y.; McDonald, Nancy; Laamanen, Curtis; LeClair, Robert J.

    2014-01-01

    Purpose: To develop a method to estimate the mean fractional volume of fat (ν ¯ fat ) within a region of interest (ROI) of a tissue sample for wide-angle x-ray scatter (WAXS) applications. A scatter signal from the ROI was obtained and use of ν ¯ fat in a WAXS fat subtraction model provided a way to estimate the differential linear scattering coefficient μ s of the remaining fatless tissue. Methods: The efficacy of the method was tested using animal tissue from a local butcher shop. Formalin fixed samples, 5 mm in diameter 4 mm thick, were prepared. The two main tissue types were fat and meat (fibrous). Pure as well as composite samples consisting of a mixture of the two tissue types were analyzed. For the latter samples, ν fat for the tissue columns of interest were extracted from corresponding pixels in CCD digital x-ray images using a calibration curve. The means ν ¯ fat were then calculated for use in a WAXS fat subtraction model. For the WAXS measurements, the samples were interrogated with a 2.7 mm diameter 50 kV beam and the 6° scattered photons were detected with a CdTe detector subtending a solid angle of 7.75 × 10 −5 sr. Using the scatter spectrum, an estimate of the incident spectrum, and a scatter model, μ s was determined for the tissue in the ROI. For the composite samples, a WAXS fat subtraction model was used to estimate the μ s of the fibrous tissue in the ROI. This signal was compared to μ s of fibrous tissue obtained using a pure fibrous sample. Results: For chicken and beef composites, ν ¯ fat =0.33±0.05 and 0.32 ± 0.05, respectively. The subtractions of these fat components from the WAXS composite signals provided estimates of μ s for chicken and beef fibrous tissue. The differences between the estimates and μ s of fibrous obtained with a pure sample were calculated as a function of the momentum transfer x. A t-test showed that the mean of the differences did not vary from zero in a statistically significant way thereby

  8. In vitro autoradiographic studies for determination of mitotic index and labelling index in biopsies of the human oral mucosa

    International Nuclear Information System (INIS)

    Etzbach, T.

    1980-01-01

    In order to find the most favourable method of incubation for in-vitro autoradiographies of biopsies of human oral mucosa, tissue biopsies were taken from oral mucosa transplants of 10 patients (7 females, 3 males) and either fixed or incubated at once. The author then investigated the mitotic index of the non-incubated tissue specimens, the mitotic index of the tissue specimens incubated in atmospheric conditions (A), and the mitotic index of the tissue specimens incubated under pressure (B). Simultaneously, autoradiographs of the incubated tissue specimens were prepared in order to determine their labelling indices. The mitotic indices of the non-incubated tissue specimen were found to differ significantly from those of the A-incubated tissue specimens. A similar difference was found between the mitotic indices of the A- and B-incubated tissue biopsies. Further, the labelling indices of A autoradiographs differed significantly from the labelling indices of B autoradiographs. The findings suggest that incubation with an excess oxygen pressure of 2 bar is the method of choice for in-vitro studies of human oral mucosa as the cells retain their specific activity and cell processes will continue unhindered. Further, the findings can be transferred to in-vivo conditions with a reasonable error rate. (orig./MG) [de

  9. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Vavpetič, P., E-mail: primoz.vavpetic@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vogel-Mikuš, K. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Jeromel, L. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Ogrinc Potočnik, N. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); FOM-Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands); Pongrac, P. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Department of Plant Physiology, University of Bayreuth, Universitätstr. 30, 95447 Bayreuth (Germany); Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm{sup 2} and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  10. The Expression of Adipogenic Genes in Adipose Tissues of Feedlot Steers Fed Supplementary Palm Oil or Soybean Oil

    Directory of Open Access Journals (Sweden)

    Seong Ho Choi

    2016-03-01

    Full Text Available We hypothesized that supplementing finishing diets with palm oil would promote adipogenic gene expression and stearoyl-CoA desaturase (SCD gene expression in subcutaneous (s.c. and intramuscular (i.m. adipose tissues of feedlot steers. Eighteen Angus and Angus crossbred steers were assigned to three groups of 6 steers and fed a basal diet (control, with 3% palm oil, or with 3% soybean oil, for 70 d, top-dressed daily. Tailhead s.c. adipose tissue was obtained by biopsy at 14 d before the initiation of dietary treatments and at 35 d of dietary treatments. At slaughter, after 70 d of dietary treatment, tailhead s.c. adipose tissue and i.m. adipose tissue were obtained from the longissimus thoracis muscle. Palm oil increased plasma palmitic acid and soybean oil increased plasma linoleic acid and α-linolenic acid relative to the initial sampling time. Expression of AMP-activated protein kinase alpha (AMPKα and peroxisome proliferator-activated receptor gamma (PPARγ increased between the initial and intermediate biopsies and declined thereafter (p<0.03. SCD gene expression did not change between the initial and intermediate biopsies but declined by over 75% by the final period (p = 0.04, and G-coupled protein receptor 43 (GPR43 gene expression was unaffected by diet or time on trial. Soybean oil decreased (p = 0.01 PPARγ gene expression at the intermediate sample time. At the terminal sample time, PPARγ and SCD gene expression was less in i.m. adipose tissue than in s.c. adipose tissue (p<0.05. AMPKα gene expression was less in s.c. adipose tissue of palm oil-fed steers than in control steers (p = 0.04 and CCAAT enhancer binding protein-beta (CEBPβ gene expression was less in s.c. and i.m. adipose tissues of palm oil-fed steers than in soybean oil-fed steers (p<0.03. Soybean oil decreased SCD gene expression in s.c. adipose tissue (p = 0.05; SCD gene expression in palm oil-fed steers was intermediate between control and soybean oil-fed steers

  11. Implementation of Upright Digital Breast Tomosynthesis-guided Stereotactic Biopsy.

    Science.gov (United States)

    Omofoye, Toma S; Martaindale, Sarah; Teichgraeber, Davis C; Parikh, Jay R

    2017-11-01

    With growing adoption of digital breast tomosynthesis, an increasing number of imaging abnormalities are being identified only by tomosynthesis. Upright digital breast tomosynthesis-guided stereotactic biopsy is a proven method for sampling these abnormalities as well as abnormalities traditionally evaluated using conventional stereotactic biopsy. In this article, we describe the technique of upright digital breast tomosynthesis-guided stereotactic biopsy and outline a systematic operational approach to implementation of this technique in clinical radiology practices. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. HISTOMORPHOLOGICAL PROFILE OF PROSTATE BIOPSIES AND CORRELATION WITH SERUM TPSA LEVEL

    Directory of Open Access Journals (Sweden)

    Laishram Deepak Kumar

    2017-11-01

    Full Text Available BACKGROUND In our study, 50 cases of transurethral prostate biopsies were evaluated histopathologically in the Department of Pathology in collaboration with Department of Urology, Regional Institute of Medical Sciences, Imphal, from October 2013 to September 2015. Total PSA (tPSA was estimated from serum samples in all cases. MATERIALS AND METHODS A total of 50 patients with elevated serum tPSA levels were inducted in this study and prostate needle biopsies taken. Matched prostatectomy specimens were also obtained for 7 cases. Specimens were kept in 10% formalin saline, grossing done and tissues processed. H and E stained sections were examined and the different histomorphological features noted. Gleason scoring system was used in cancers to stratify it. RESULTS Out of the 50 cases, 30 malignant (all adenocarcinomas, 4 premalignant and 16 benign cases were found. Gleason scoring on needle biopsies were compared against the prostatectomy specimens. In 5 carcinoma cases with Gleason score 3+3=6 on needle biopsy, 4 cases had similar findings in the corresponding prostatectomy specimens, however, it was upgraded in 1 case. Intermediate differentiation prostatic carcinomas with Gleason score 3+4=7 in needle biopsies were comparable with prostatectomy specimens in 2 cases. The differentiation of prostatic carcinoma vis-a-vis Gleason scoring correlated well with the PSA values. In carcinomas, tPSA value and the Gleason score had a very good correlation (rs = 0.908. Mean PSA value was found to increase from benign to premalignant and malignant cases, this was found to be statistically significant (p<0.05. CONCLUSION Use of newer technologies like MRI and serum PSA as a screening tool for prostate pathology have made it possible to identify prostate cancer at an earlier stage in younger age group and has an increased case detection rate. However, there is no marker to predict disease course and at times lead to overtreatment. Image-guided prostate biopsy

  13. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  14. Added value of second biopsy target in screen-detected widespread suspicious breast calcifications.

    Science.gov (United States)

    Falkner, Nathalie M; Hince, Dana; Porter, Gareth; Dessauvagie, Ben; Jeganathan, Sanjay; Bulsara, Max; Lo, Glen

    2018-06-01

    There is controversy on the optimal work-up of screen-detected widespread breast calcifications: whether to biopsy a single target or multiple targets. This study evaluates agreement between multiple biopsy targets within the same screen-detected widespread (≥25 mm) breast calcification to determine if the second biopsy adds value. Retrospective observational study of women screened in a statewide general population risk breast cancer mammographic screening program from 2009 to 2016. Screening episodes recalled for widespread calcifications where further views indicated biopsy, and two or more separate target areas were sampled within the same lesion were included. Percentage agreement and Cohen's Kappa were calculated. A total of 293317 women were screened during 761124 separate episodes with recalls for widespread calcifications in 2355 episodes. In 171 women, a second target was biopsied within the same lesion. In 149 (86%) cases, the second target biopsy result agreed with the first biopsy (κ = 0.6768). Agreement increased with increasing mammography score (85%, 86% and 92% for score 3, 4 and 5 lesions). Same day multiple biopsied lesions were three times more likely to yield concordant results compared to post-hoc second target biopsy cases. While a single target biopsy is sufficient to discriminate a benign vs. malignant diagnosis in most cases, in 14% there is added value in performing a second target biopsy. Biopsies performed prospectively are more likely to yield concordant results compared to post-hoc second target biopsy cases, suggesting a single prospective biopsy may be sufficient when results are radiological-pathological concordant; discordance still requires repeat sampling. © 2018 The Royal Australian and New Zealand College of Radiologists.

  15. Migration assay on primary culture isolated from patient's primary breast cancer tissue

    Directory of Open Access Journals (Sweden)

    ED Yuliana

    2014-12-01

    Full Text Available Background: Migration is an essential component of breast cancer metastasis, which studyhas been concentrated on culture of established breast cancer cell lines that do not accuratelyrepresent the sophistication and heterogeneity of patient's breast cancer. An attempt toperform migration assay using Boyden Chamber Assay (BCA on primary culture originatingfrom patient's breast cancer tissue was developed to accommodate upcoming study of breastcancer migration in lndonesian patients.Methods: Pathologically proven primary breast cancer tissue samples were obtained fromCiptomangunkusumo Hospital during core (n=4 and incisional (n=3 biopsies of stage llAup to stage lllA breast cancer patients. Following biopsy, the breast cancer tissue samplesunderwent processings to isolate the cancer cells. These cancer cells were -then resuspendedwithin Dulbecco's modified Eagle's medium (DMEM ahd cultured in 12-well plate. The growthof primary culture were observed and compared between the core biopsy and the incisionalbiopsy specimens. Optimization of BCA method was later performed to investigate themigration of the breast cancer primary culture towards different experirnental conditions, whichwere control, Fetal Bovine Serum (FBS, and Stromal Derived Factor-l (SDF-1. Two differentnumber of breast cancer cells were tested for the optimization of the BCA, which were 1 x 105and3x105cells.Results: None of the culture performed on core biopsy specimens grew, while one out ofthree incisional biopsy specimens grew until confluence. The one primary culture that grewwas later assesed using BCA to assess its migration index towards different experimentalconditions. Using 1 x 10s breast cancer cells in the BCA , the result of the absorbance level ofmigrated cells showed that the migration towards SDF-1 (0.529 nearly doubled the migrationtowards controlmedium (0.239 and FBS (0.209. Meanwhile, the absorbance levelwas simiiarbetween the control medium (1.050, FBS (1 .103

  16. Diagnostic yield and complications of transthoracic computed tomography-guided biopsies

    DEFF Research Database (Denmark)

    Vagn-Hansen, Chris Aksel; Pedersen, Malene Roland Vils; Rafaelsen, Søren Rafael

    2016-01-01

    , the tissue material was found to be sufficient. In 32% of the biopsies, a complication arose, mostly pneumothorax (30%), but chest drainage was needed in only 15% of the 520 cases. Patients with more than ten cigarette pack-years had a complication risk that was twice as high at that of patients with fewer...... packyears. We found that the risk of pneumothorax increased the further the lesion was from the skin surface, the smaller the lesions were and when the patient was biopsied in a lateral position. We also found a higher risk of complications in females than in males. CONCLUSIONS: CT-guided biopsy...... is an excellent tool for analysing pulmonary lesions. The present study clearly shows that the risk of developing a pneumothorax is significantly increased among smokers and former smokers with more than ten pack-years....

  17. Validation and Optimization of an Ex Vivo Assay of Intestinal Mucosal Biopsies in Crohn's Disease

    DEFF Research Database (Denmark)

    Vadstrup, Kasper; Galsgaard, Elisabeth Douglas; Gerwien, Jens

    2016-01-01

    human explant method to test drug candidates and pathophysiological conditions in CD intestinal biopsies. Mucosal biopsies from 27 CD patients and 6 healthy individuals were collected to validate an explant assay test where the polarized tissue was cultured on a novel metal mesh disk, slightly immersed...

  18. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  19. The Prostate Health Index in predicting initial prostate biopsy outcomes in Asian men with prostate-specific antigen levels of 4-10 ng/mL.

    Science.gov (United States)

    Ng, C F; Chiu, Peter K F; Lam, N Y; Lam, H C; Lee, Kim W M; Hou, Simon S M

    2014-04-01

    To investigate the role of the Prostate Health Index (phi) in prostate cancer (PCa) detection in patients with a prostate-specific antigen (PSA) level of 4-10 ng/mL receiving their first prostatic biopsy in an Asian population. This was a retrospective study of archived serum samples from patients enlisted in our tissue bank. Patients over 50 years old, with PSA level of 4-10 ng/mL, a negative digital rectal examination, and received their first prostatic biopsy between April 2008 and April 2013, were recruited. The serum sample collected before biopsy was retrieved for the measurement of various PSA derivatives and the phi value was calculated for each patient. The performance of these parameters in predicting the prostatic biopsy results was assessed. Two hundred and thirty consecutive patients, with 21 (9.13 %) diagnosed with PCa, were recruited for this study. Statistically significant differences between PCa patients and non-PCa patients were found for total PSA, PSA density, [-2]proPSA (p2PSA), free-to-total PSA ratio (%fPSA), p2PSA-to-free PSA ratio (%p2PSA), and phi. The areas under the curve of the receiver operating characteristic curve for total PSA, PSA density, %fPSA, %p2PSA, and phi were 0.547, 0.634, 0.654, 0.768, and 0.781, respectively. The phi was the best predictor of the prostatic biopsies results. At a sensitivity of 90 %, the use of the phi could have avoided unnecessary biopsies in 104 (45.2 %) patients. Use of the phi could improve the accuracy of PCa detection in patients with an elevated PSA level and thus avoid unnecessary prostatic biopsies.

  20. SU-E-J-31: Biodynamic Imaging of Cancer Tissue and Response to Chemotherapy

    International Nuclear Information System (INIS)

    Nolte, D; Turek, J; Childress, M; An, R; Merrill, D; Matei, D

    2014-01-01

    Purpose: To measure intracellular motions inside three-dimensional living cancer tissue samples to establish a novel set of biodynamic biomarkers that assess tissue proliferative activity and sensitivity or resistance to chemotherapy. Methods: Biodynamic imaging (BDI) uses digital holography with low-coherence low-intensity light illumination to construct 3D holograms from depths up to a millimeter deep inside cancer tissue models that include multicellular tumor spheroids and ex vivo cancer biopsies from canine non-Hodgkins lymphoma and epithelial ovarian cancer (EOC) mouse explants. Intracellular motions modulate the holographic intensity with frequencies related to the Doppler effect caused by the motions of a wide variety of intracellular components. These motions are affected by applied therapeutic agents, and BDI produces unique fingerprints of the action of specific drugs on the motions in specific cell types. In this study, chemotherapeutic agents (doxorubicin for canine lymphoma and oxoplatin for ovarian) are applied to the living tissue models and monitored over 10 hours by BDI. Results: Multicellular spheroids and patient biopsies are categorized as either sensitive or insensitive to applied therapeutics depending on the intracellular Doppler signatures of chemotherapy response. For both lymphoma and EOC there is strong specificity to the two types of sensitivities, with sensitive cell lines and biopsies exhibiting a global cessation of proliferation and strong suppression of metabolic activity, while insensitive cell lines and biopsies show moderate activation of Doppler frequencies associated with membrane processes and possible membrane trafficking. Conclusion: This work supports the hypothesis that biodynamic biomarkers from three-dimensional living tumor tissue, that includes tissue heterogeneity and measured within 24 hours of surgery, is predictive of near-term patient response to therapy. Future work will correlate biodynamic biomarkers with

  1. SU-E-J-31: Biodynamic Imaging of Cancer Tissue and Response to Chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nolte, D; Turek, J; Childress, M; An, R; Merrill, D [Purdue University, West Lafayette, IN (United States); Matei, D [Indiana University School of Medicine, Indianapolis, IN (United States)

    2014-06-01

    Purpose: To measure intracellular motions inside three-dimensional living cancer tissue samples to establish a novel set of biodynamic biomarkers that assess tissue proliferative activity and sensitivity or resistance to chemotherapy. Methods: Biodynamic imaging (BDI) uses digital holography with low-coherence low-intensity light illumination to construct 3D holograms from depths up to a millimeter deep inside cancer tissue models that include multicellular tumor spheroids and ex vivo cancer biopsies from canine non-Hodgkins lymphoma and epithelial ovarian cancer (EOC) mouse explants. Intracellular motions modulate the holographic intensity with frequencies related to the Doppler effect caused by the motions of a wide variety of intracellular components. These motions are affected by applied therapeutic agents, and BDI produces unique fingerprints of the action of specific drugs on the motions in specific cell types. In this study, chemotherapeutic agents (doxorubicin for canine lymphoma and oxoplatin for ovarian) are applied to the living tissue models and monitored over 10 hours by BDI. Results: Multicellular spheroids and patient biopsies are categorized as either sensitive or insensitive to applied therapeutics depending on the intracellular Doppler signatures of chemotherapy response. For both lymphoma and EOC there is strong specificity to the two types of sensitivities, with sensitive cell lines and biopsies exhibiting a global cessation of proliferation and strong suppression of metabolic activity, while insensitive cell lines and biopsies show moderate activation of Doppler frequencies associated with membrane processes and possible membrane trafficking. Conclusion: This work supports the hypothesis that biodynamic biomarkers from three-dimensional living tumor tissue, that includes tissue heterogeneity and measured within 24 hours of surgery, is predictive of near-term patient response to therapy. Future work will correlate biodynamic biomarkers with

  2. A method to estimate the fractional fat volume within a ROI of a breast biopsy for WAXS applications: Animal tissue evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Robert Y., E-mail: rx-tang@laurentian.ca [Biomolecular Sciences Program, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6 (Canada); McDonald, Nancy, E-mail: mcdnancye@gmail.com; Laamanen, Curtis, E-mail: cx-laamanen@laurentian.ca [Department of Physics, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6 (Canada); LeClair, Robert J., E-mail: rleclair@laurentian.ca [Department of Physics, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6, Canada and Biomolecular Sciences Program, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario P3E 2C6 (Canada)

    2014-11-01

    Purpose: To develop a method to estimate the mean fractional volume of fat (ν{sup ¯}{sub fat}) within a region of interest (ROI) of a tissue sample for wide-angle x-ray scatter (WAXS) applications. A scatter signal from the ROI was obtained and use of ν{sup ¯}{sub fat} in a WAXS fat subtraction model provided a way to estimate the differential linear scattering coefficient μ{sub s} of the remaining fatless tissue. Methods: The efficacy of the method was tested using animal tissue from a local butcher shop. Formalin fixed samples, 5 mm in diameter 4 mm thick, were prepared. The two main tissue types were fat and meat (fibrous). Pure as well as composite samples consisting of a mixture of the two tissue types were analyzed. For the latter samples, ν{sub fat} for the tissue columns of interest were extracted from corresponding pixels in CCD digital x-ray images using a calibration curve. The means ν{sup ¯}{sub fat} were then calculated for use in a WAXS fat subtraction model. For the WAXS measurements, the samples were interrogated with a 2.7 mm diameter 50 kV beam and the 6° scattered photons were detected with a CdTe detector subtending a solid angle of 7.75 × 10{sup −5} sr. Using the scatter spectrum, an estimate of the incident spectrum, and a scatter model, μ{sub s} was determined for the tissue in the ROI. For the composite samples, a WAXS fat subtraction model was used to estimate the μ{sub s} of the fibrous tissue in the ROI. This signal was compared to μ{sub s} of fibrous tissue obtained using a pure fibrous sample. Results: For chicken and beef composites, ν{sup ¯}{sub fat}=0.33±0.05 and 0.32 ± 0.05, respectively. The subtractions of these fat components from the WAXS composite signals provided estimates of μ{sub s} for chicken and beef fibrous tissue. The differences between the estimates and μ{sub s} of fibrous obtained with a pure sample were calculated as a function of the momentum transfer x. A t-test showed that the mean of the

  3. Determination of d-limonene in adipose tissue by gas chromatography-mass spectrometry

    Science.gov (United States)

    Miller, Jessica A.; Hakim, Iman A.; Thomson, Cynthia; Thompson, Patricia; Chow, H-H. Sherry

    2008-01-01

    We developed a novel method for analyzing d-limonene levels in adipose tissue. Fat samples were subjected to saponification followed by solvent extraction. d-Limonene in the sample extract was analyzed using gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring. Linear calibration curves were established over the mass range of 79.0-2,529 ng d-limonene per 0.1 grams of adipose tissue. Satisfactory within day precision (RSD 6.7 to 9.6%) and accuracy (% difference of −2.7 to 3.8%) and between day precision (RSD 6.0 to 10.7%) and accuracy (% difference of 1.8 to 2.6%) were achieved. The assay was successfully applied to human fat biopsy samples from a d-limonene feeding trial. PMID:18571481

  4. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  5. Nonfocal renal biopsies: adequacy and factors affecting a successful outcome.

    Science.gov (United States)

    Goldstein, Mark A; Atri, Mostafa; O'Malley, Martin; Jacks, Lindsay; John, Rohan; Herzenberg, Andrew; Reich, Heather; Ghai, Sangeet

    2013-01-01

    The purpose of this study was to evaluate factors affecting the success of ultrasound-guided core biopsy of kidneys and determine the optimum number of passes. This retrospective study evaluated 484 nonfocal renal biopsies performed with 18-gauge side-notch biopsy needles. Number of biopsy passes, serum creatinine, body mass index, needle type, transplant age, kidney size, diabetic status, and operator were evaluated as predictors of the number of biopsy passes. Four hundred seventy-four biopsies (338 transplant, 136 native) were included with mean number of passes 2.87 (3.1 native vs 2.78 transplant; P = 0.002). Mean number of glomeruli yielded per pass was 6.9 (7.2 transplant vs 6.1 native; P = 0.0002) with 3 passes adequate for histological diagnosis in 84% of biopsies. Native kidney, increasing serum creatinine level, trainee biopsy operator, and use of a Temno needle were found to be independent predictors of having more than 3 biopsy passes on multivariate analysis. Age, sex, body mass index, diabetic status, and kidney size were not associated with the number of biopsy passes. The success of a nonfocal renal biopsy has many influencing variables, and in the absence of an on-site electron microscopy technologist to immediately evaluate biopsy samples, 3 passes with an 18-gauge needle would be adequate in 84% of kidneys to achieve a histological diagnosis, with 2 passes needed for transplant kidneys to meet the Banff 97 criteria.

  6. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  7. Membrane supported scaffold architectures for tissue engineering

    NARCIS (Netherlands)

    Bettahalli Narasimha, M.S.

    2011-01-01

    Tissue engineering aims at restoring or regenerating a damaged tissue. Often the tissue recreation occurs by combining cells, derived from a patient biopsy, onto a 3D porous matrix, functioning as a scaffold. One of the current limitations of tissue engineering is the inability to provide sufficient

  8. Support vector machine classification and validation of cancer tissue samples using microarray expression data.

    Science.gov (United States)

    Furey, T S; Cristianini, N; Duffy, N; Bednarski, D W; Schummer, M; Haussler, D

    2000-10-01

    DNA microarray experiments generating thousands of gene expression measurements, are being used to gather information from tissue and cell samples regarding gene expression differences that will be useful in diagnosing disease. We have developed a new method to analyse this kind of data using support vector machines (SVMs). This analysis consists of both classification of the tissue samples, and an exploration of the data for mis-labeled or questionable tissue results. We demonstrate the method in detail on samples consisting of ovarian cancer tissues, normal ovarian tissues, and other normal tissues. The dataset consists of expression experiment results for 97,802 cDNAs for each tissue. As a result of computational analysis, a tissue sample is discovered and confirmed to be wrongly labeled. Upon correction of this mistake and the removal of an outlier, perfect classification of tissues is achieved, but not with high confidence. We identify and analyse a subset of genes from the ovarian dataset whose expression is highly differentiated between the types of tissues. To show robustness of the SVM method, two previously published datasets from other types of tissues or cells are analysed. The results are comparable to those previously obtained. We show that other machine learning methods also perform comparably to the SVM on many of those datasets. The SVM software is available at http://www.cs. columbia.edu/ approximately bgrundy/svm.

  9. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Solid tissue culture for cytogenetic analysis: a collaborative survey for the Association of Clinical Cytogeneticists.

    Science.gov (United States)

    Rodgers, C S; Creasy, M R; Fitchett, M; Maliszewska, C T; Pratt, N R; Waters, J J

    1996-01-01

    AIMS: To survey the diagnostic service provided by UK laboratories for the culture of solid tissue samples (excluding tumours) and in particular to examine the variation in culture success rates and the problems of maternal cell overgrowth. METHODS: Twenty seven laboratories took part in a collaborative survey during 1992. Each laboratory submitted data on up to a maximum of 60 consecutive specimens (n = 1361) over a six month period. RESULTS: Skin specimens, the largest category received (n = 520), were the most problematic (51% success rate). Culture success rates were significantly lower (43%) when skin specimens (n = 140) were transported dry to the laboratory. Success rates for skin specimens also varied, depending on the origin of the specimen, from 18% for intra-uterine deaths (IUD) (n = 94) to 85% for neonatal deaths (n = 33) and 83% for live patients (n = 54). Culture of selected extra-fetal tissues from IUD, stillbirths and following elective termination of pregnancy (TOP) gave comparable success rates to those achieved for skin samples from neonatal deaths and live births. Skewed sex ratios, female > male, were identified for products of conception (POC) (n = 298) and placental biopsy specimens (n = 97). CONCLUSIONS: By appropriate selection, transport and processing of tissues, and in particular by avoiding relying solely on skin samples from IUD, stillbirths and TOP, an increase in culture success rates for solid tissue samples submitted for cytogenetic analysis could be achieved. The high risk of maternal cell contamination from POC and placental biopsy specimens was also identified in this survey. PMID:8881913

  11. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  12. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  13. BONE MARROW BIOPSY IN EVALUATION OF HAEMATOLOGICAL DISORDERS

    Directory of Open Access Journals (Sweden)

    Sandhya Rani Sahoo

    2017-04-01

    Full Text Available BACKGROUND Bone Marrow Trephine Biopsy (BMTB and aspiration is critical for diagnosis, prognostic evaluation and monitoring therapeutic response. BMTB is of greater value in assessing cellularity, degree of fibrosis, marrow architecture and especially when aspiration is dry tap. At the same time, it provides sample for immunohistochemistry. MATERIALSAND METHODS It is a single centre observational study conducted from July 2014 to July 2016 in Department of Pathology, S.C.B. Medical College, Cuttack, which included both cell block and touch imprint along with trephine biopsy. Cases selected where lymphoma studied for pattern and extent of infiltration. Aspiration with dry tap and selected cases of myeloproliferative disorders, myelodysplastic syndrome, leukaemia (both acute and chronic, anaemia, multiple myeloma were studied. Jamshidi needle was used for biopsy. Samples obtained were formalin preserved, kept in decalcification solution (Hammersmith protocol and H and E slides prepared. Special stain-like reticulin and Masson’s trichrome were used for grading of fibrosis. Immunohistochemistry was done on selected cases of lymphoma. RESULTS Out of total 100 cases studied, 60 were of haematopoietic and lymphoid neoplasms, 12 anaemia, 20 secondary metastasis, 8 miscellaneous (1 haemophagocytic lymphohistiocytic disease, 1 storage disease, 1 granulomatous and 5 ITP. CONCLUSION The study was conducted to establish the advantage of bone marrow biopsy in inadequate and failed aspiration, but both are complementary to each other and together provide a comprehensive evaluation of the bone marrow. Bone marrow fibrosis are well accessed and increased detection of tumour cells in suspected secondary metastasis. Special stains, IHC, cytogenetic study can be done over biopsy block.

  14. Oral pathology diagnosis by means of micro-Raman spectroscopy on biopsies and blood serum

    Science.gov (United States)

    Zenone, F.; Lepore, M.; Perna, G.; Carmone, P.; Delfino, I.; Gaeta, G. M.; Capozzi, V.

    2007-02-01

    Pemphigus vulgaris is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. In this case micro-Raman spectroscopy (μ-RS) can provide a powerful tool for a not invasive analysis of biological tissue for biopsy and in vivo investigation. Based on the evaluation of molecular vibration frequencies, the μ-RS is able to detect the main molecular bonds of protein constituents, as the C-H and C-C ones. Changes in frequency or in the relative intensity of the vibration modes revealed by μ-RS can be related to changes of chemical bond and of protein structure induced by pathology. Quantitative information on the intensity variation of specific Raman lines can be extracted by Partial Least Square (PLS) analysis. μ-RS was performed on some samples of oral tissue and blood serum from informed patients affected by pemphigus vulgaris (an oral pathology) at different pathology stages. The spectra were measured by means of a Raman confocal microspectrometer apparatus using the 633 nm line of a He- Ne laser source. The main protein bonds are clearly detectable in the considered samples giving important information on the integrity and on the state of tissue and blood serum components (lipids and proteins), and consequently on the occurrence of pathology.

  15. Development of a permanently controllable rotating biopsy device. Pt. I. Theoretical considerations and in-vitro results for five different prototypes

    International Nuclear Information System (INIS)

    Schaefer, Philipp Jost; Jahnke, T.; Andres, H.; Heller, M.; Schaefer, F.K.; Hedderich, J.

    2009-01-01

    Purpose: to develop different prototypes of permanently controllable rotating biopsy devices with determination of the most efficient prototype in biopsies in bovine myocardium. Materials and Methods: Five different prototypes of 18-gauge rotating biopsy devices were designed and constructed, four (1-4) with various drill-like cutting edges and one (5) cannula type with a lancet-like helically bent cutting edge. Using bovine myocardium as the biopsy tissue, n = 100 specimens per prototype were obtained, and a quantitative analysis including tissue fragmentation, length in mm and weight in mg was carried out. For statistical analysis, the chi-square test for tissue fragmentation and Kruskal-Wallis test for the parameters length and weight were calculated. Results: prototype 5 showed the highest rate of extraction of one-fragment specimens in n=66 cases and the lowest rate of failure to obtain tissue in n=11 cases. The mean length/weight were 4.15 mm/3.91 mg for prototype 1, 1.80 mm/1.66 mg for prototype 2, 4.61 mm/3.28 mg for prototype 3, 5.20 mm/3.74 mg for prototype 4, and 9.57 mm/6.97 mg for prototype 5. In all three categories, prototype 5 was significantly superior to the prototypes 1-4 with p < 0.001. Conclusion: the cannula type with a lancet-like helically bent cutting edge proved to be the most efficient prototype and may now be tested competitively against established automated biopsy devices in vitro. (orig.)

  16. The use of special stains in liver biopsy interpretation: Implications ...

    African Journals Online (AJOL)

    Materials and Methods: The formalin fixed paraffin embedded blocks of liver biopsies reported in two histopathology laboratories between 2008 and 2013 were retrieved. These were stained with H and E and the following standard special stains for liver tissue histology – Perl's Prussian blue, reticulin, Sirius red, Shikata ...

  17. Case Report: Ischaemic appendicitis post mesenteric biopsy [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Marianna Zukiwskyj

    2016-01-01

    Full Text Available A common indication for laparoscopic mesenteric lymph node biopsy is to provide a tissue diagnosis in the absence of palpable peripheral nodes via a minimally invasive approach.  There are no reports to date of ischaemia to the appendix as a complication of this procedure.   We report the case of a 34-year-old lady who underwent a mesenteric biopsy for a lesion found incidentally on CT to investigate longstanding abdominal pain, and 2 days later required an appendicectomy for ischaemic appendicitis.

  18. 3D on-chip microscopy of optically cleared tissue

    Science.gov (United States)

    Zhang, Yibo; Shin, Yoonjung; Sung, Kevin; Yang, Sam; Chen, Harrison; Wang, Hongda; Teng, Da; Rivenson, Yair; Kulkarni, Rajan P.; Ozcan, Aydogan

    2018-02-01

    Traditional pathology relies on tissue biopsy, micro-sectioning, immunohistochemistry and microscopic imaging, which are relatively expensive and labor-intensive, and therefore are less accessible in resource-limited areas. Low-cost tissue clearing techniques, such as the simplified CLARITY method (SCM), are promising to potentially reduce the cost of disease diagnosis by providing 3D imaging and phenotyping of thicker tissue samples with simpler preparation steps. However, the mainstream imaging approach for cleared tissue, fluorescence microscopy, suffers from high-cost, photobleaching and signal fading. As an alternative approach to fluorescence, here we demonstrate 3D imaging of SCMcleared tissue using on-chip holography, which is based on pixel-super-resolution and multi-height phase recovery algorithms to digitally compute the sample's amplitude and phase images at various z-slices/depths through the sample. The tissue clearing procedures and the lens-free imaging system were jointly optimized to find the best illumination wavelength, tissue thickness, staining solution pH, and the number of hologram heights to maximize the imaged tissue volume, minimize the amount of acquired data, while maintaining a high contrast-to-noise ratio for the imaged cells. After this optimization, we achieved 3D imaging of a 200-μm thick cleared mouse brain tissue over a field-of-view of based microscope (20× 0.75NA). Moreover, the lens-free microscope achieves an order-of-magnitude better data efficiency compared to its lens-based counterparts for volumetric imaging of samples. The presented low-cost and high-throughput lens-free tissue imaging technique enabled by CLARITY can be used in various biomedical applications in low-resource-settings.

  19. Human papillomavirus detection in paraffin-embedded colorectal cancer tissues.

    Science.gov (United States)

    Tanzi, Elisabetta; Bianchi, Silvia; Frati, Elena R; Amicizia, Daniela; Martinelli, Marianna; Bragazzi, Nicola L; Brisigotti, Maria Pia; Colzani, Daniela; Fasoli, Ester; Zehender, Gianguglielmo; Panatto, Donatella; Gasparini, Roberto

    2015-01-01

    Human papillomavirus (HPV) has a well-recognized aetiological role in the development of cervical cancer and other anogenital tumours. Recently, an association between colorectal cancer and HPV infection has been suggested, although this is still controversial. This study aimed at detecting and characterizing HPV infection in 57 paired biopsies from colorectal cancers and adjacent intact tissues using a degenerate PCR approach. All amplified fragments were genotyped by means of sequencing. Overall, HPV prevalence was 12.3 %. In particular, 15.8 % of tumour tissues and 8.8 % of non-cancerous tissue samples were HPV DNA-positive. Of these samples, 85.7 % were genotyped successfully, with 41.7 % of sequences identifying four genotypes of the HR (high oncogenic risk) clade Group 1; the remaining 58.3 % of HPV-genotyped specimens had an unclassified β-HPV. Examining additional cases and analysing whole genomes will help to outline the significance of these findings.

  20. The contribution of CT-guided transthoracic lung biopsy to the diagnosis of organising pneumonia.

    Science.gov (United States)

    Metzger, F; Pernet, D; Manzoni, P; Ranfaing, E; Dalphin, J-C

    2010-09-01

    Organising pneumonia is a pulmonary disease with variable clinical and radiological features and with many differential diagnoses. Diagnosis is based on histology obtained by either transbronchial or surgical lung biopsy but these techniques have several disadvantages. The aim of this study was to evaluate the diagnostic yield of CT-guided transthoracic lung biopsy in organising pneumonia and to compare it to the usual diagnostic tools. Six cases of organising pneumonia diagnosed with CT-guided lung biopsy are reported and discussed. The role of CT-guided lung biopsy in the diagnosis of organising pneumonia was also reviewed in the literature. CT-guided transthoracic lung biopsies provided a higher rate of adequate samples than transbronchial biopsies (92-100% versus 77-86%). The samples were larger, which reduced the risks of misdiagnosis and increased the diagnostic yield (88-97% versus 26-55% in pulmonary nodules and 42-100% versus 66-75% in diffuse pulmonary disease). Complications were rare and generally not serious. CT-guided transthoracic lung biopsy may be considered in place of transbronchial biopsy in the diagnosis of organising pneumonia. Surgical lung biopsy remains the gold standard method for diagnosis. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  1. Percutaneous liver biopsy. Overview of different techniques; Perkutane Leberbiopsie. Uebersicht ueber verschiedene Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Kettenbach, J.; Blum, M.; El-RaBadi, K.; Langenberger, H.; Happel, B.; Berger, J.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Universitaet Wien (Austria)

    2005-01-01

    To classify a liver tumor, image-guided percutaneous biopsy of a liver lesion is indicated. Using ultrasound (US) to guide a biopsy needle into a liver lesion has been proven useful and safe. If a lesion cannot be seen on US or the access to a lesion has been complicated by its position, CT-guided biopsy can be performed. If a lesion cannot be delineated on US or CT, MR-guided biopsy is recommended. Using hepatospecific contrast agents, the time span to delineate tumor tissue can be prolonged. To differentiate diffuse liver disease, transvenous biopsy under fluoroscopic control can be performed if a percutaneous biopsy is contraindicated. In recent years fine-needle aspiration biopsy has been increasingly replaced by coaxial 14-20 G core biopsy, which is a safe and efficient technique to classify liver lesions and has a low complication rate. (orig.) [German] Zur definitiven Klaerung der Dignitaet und Tumorklasse einer Leberlaesion ist eine bildgesteuerte perkutane Biopsie indiziert. Unter Verwendung der Sonographie ist das Verfahren treffsicher und einfach. Die computertomographiegezielte Biopsie ist wegen der ueberlagerungsfreien, reproduzierbaren Darstellung von Leberherden und ihren Nachbarstrukturen in vielen Faellen besser geeignet. Fuer Laesionen, die sich weder mit Ultraschall noch mit CT biopsieren lassen, bietet sich die Magnetresonanztomographie an. Durch den Einsatz leberspezifischer Kontrastmittel kann das Zeitfenster zur Durchfuehrung einer Biopsie verlaengert werden. Zur Abklaerung diffuser Lebererkrankungen wird bei kontraindizierter perkutaner Biopsie eine transvenoese Leberbiopsie unter Durchleuchtung empfohlen. Die in den 1980er Jahren propagierte Feinnadelaspirationsbiopsie wurde zunehmend durch Stanzbiopsien (Durchmesser 14-20 gg) in koaxialer Technik ersetzt, da diese eine zuverlaessige artdiagnostische Klassifikation bei niedriger Komplikationsrate ermoeglichen. (orig.)

  2. Trace element contamination in feather and tissue samples from Anna’s hummingbirds

    Science.gov (United States)

    Mikoni, Nicole A.; Poppenga, Robert H.; Ackerman, Joshua T.; Foley, Janet E.; Hazlehurst, Jenny; Purdin, Güthrum; Aston, Linda; Hargrave, Sabine; Jelks, Karen; Tell, Lisa A.

    2017-01-01

    Trace element contamination (17 elements; Be, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Ba, Hg, Tl, and Pb) of live (feather samples only) and deceased (feather and tissue samples) Anna's hummingbirds (Calypte anna) was evaluated. Samples were analyzed using inductively coupled plasma-mass spectrometry (ICP-MS; 17 elements) and atomic absorption spectrophotometry (Hg only). Mean plus one standard deviation (SD) was considered the benchmark, and concentrations above the mean + 1 SD were considered elevated above normal. Contour feathers were sampled from live birds of varying age, sex, and California locations. In order to reduce thermal impacts, minimal feathers were taken from live birds, therefore a novel method was developed for preparation of low mass feather samples for ICP-MS analysis. The study found that the novel feather preparation method enabled small mass feather samples to be analyzed for trace elements using ICP-MS. For feather samples from live birds, all trace elements, with the exception of beryllium, had concentrations above the mean + 1 SD. Important risk factors for elevated trace element concentrations in feathers of live birds were age for iron, zinc, and arsenic, and location for iron, manganese, zinc, and selenium. For samples from deceased birds, ICP-MS results from body and tail feathers were correlated for Fe, Zn, and Pb, and feather concentrations were correlated with renal (Fe, Zn, Pb) or hepatic (Hg) tissue concentrations. Results for AA spectrophotometry analyzed samples from deceased birds further supported the ICP-MS findings where a strong correlation between mercury concentrations in feather and tissue (pectoral muscle) samples was found. These study results support that sampling feathers from live free-ranging hummingbirds might be a useful, non-lethal sampling method for evaluating trace element exposure and provides a sampling alternative since their small body size limits traditional sampling of blood and tissues. The

  3. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    International Nuclear Information System (INIS)

    See, Teik Choon; Thompson, Barbara C.; Howie, Alexander J.; Karamshi, M.; Papadopoulou, Anthie M.; Davies, Neil; Tibballs, Jonathan

    2008-01-01

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient

  4. High-throughput simultaneous analysis of RNA, protein, and lipid biomarkers in heterogeneous tissue samples.

    Science.gov (United States)

    Reiser, Vladimír; Smith, Ryan C; Xue, Jiyan; Kurtz, Marc M; Liu, Rong; Legrand, Cheryl; He, Xuanmin; Yu, Xiang; Wong, Peggy; Hinchcliffe, John S; Tanen, Michael R; Lazar, Gloria; Zieba, Renata; Ichetovkin, Marina; Chen, Zhu; O'Neill, Edward A; Tanaka, Wesley K; Marton, Matthew J; Liao, Jason; Morris, Mark; Hailman, Eric; Tokiwa, George Y; Plump, Andrew S

    2011-11-01

    With expanding biomarker discovery efforts and increasing costs of drug development, it is critical to maximize the value of mass-limited clinical samples. The main limitation of available methods is the inability to isolate and analyze, from a single sample, molecules requiring incompatible extraction methods. Thus, we developed a novel semiautomated method for tissue processing and tissue milling and division (TMAD). We used a SilverHawk atherectomy catheter to collect atherosclerotic plaques from patients requiring peripheral atherectomy. Tissue preservation by flash freezing was compared with immersion in RNAlater®, and tissue grinding by traditional mortar and pestle was compared with TMAD. Comparators were protein, RNA, and lipid yield and quality. Reproducibility of analyte yield from aliquots of the same tissue sample processed by TMAD was also measured. The quantity and quality of biomarkers extracted from tissue prepared by TMAD was at least as good as that extracted from tissue stored and prepared by traditional means. TMAD enabled parallel analysis of gene expression (quantitative reverse-transcription PCR, microarray), protein composition (ELISA), and lipid content (biochemical assay) from as little as 20 mg of tissue. The mean correlation was r = 0.97 in molecular composition (RNA, protein, or lipid) between aliquots of individual samples generated by TMAD. We also demonstrated that it is feasible to use TMAD in a large-scale clinical study setting. The TMAD methodology described here enables semiautomated, high-throughput sampling of small amounts of heterogeneous tissue specimens by multiple analytical techniques with generally improved quality of recovered biomolecules.

  5. Adenovirus 36 DNA in human adipose tissue.

    Science.gov (United States)

    Ponterio, E; Cangemi, R; Mariani, S; Casella, G; De Cesare, A; Trovato, F M; Garozzo, A; Gnessi, L

    2015-12-01

    Recent studies have suggested a possible correlation between obesity and adenovirus 36 (Adv36) infection in humans. As information on adenoviral DNA presence in human adipose tissue are limited, we evaluated the presence of Adv36 DNA in adipose tissue of 21 adult overweight or obese patients. Total DNA was extracted from adipose tissue biopsies. Virus detection was performed using PCR protocols with primers against specific Adv36 fiber protein and the viral oncogenic E4orf1 protein nucleotide sequences. Sequences were aligned with the NCBI database and phylogenetic analyses were carried out with MEGA6 software. Adv36 DNA was found in four samples (19%). This study indicates that some individuals carry Adv36 in the visceral adipose tissue. Further studies are needed to determine the specific effect of Adv36 infection on adipocytes, the prevalence of Adv36 infection and its relationship with obesity in the perspective of developing a vaccine that could potentially prevent or mitigate infection.

  6. Immunophenotype of cells within cervine rectoanal mucosa-associated lymphoid tissue and mesenteric lymph nodes.

    Science.gov (United States)

    Dagleish, M P; Finlayson, J; Steele, P J; Pang, Y; Hamilton, S; Eaton, S L; Sales, J; González, L; Chianini, F

    2012-05-01

    Rectoanal mucosa-associated lymphoid tissue (RAMALT) is a part of the lymphoid system that can be sampled easily in live animals, especially ruminants. RAMALT biopsy is useful for the diagnosis of transmissible spongiform encephalopathies, including scrapie in sheep and goats and chronic wasting disease (CWD) in cervids. Diagnosis is reliant on detection of abnormal prion protein (PrP(d)), which is associated with lymphoid follicles. For enzyme linked immunosorbent assays (ELISAs) detecting PrP(d) it is necessary to ensure that lymphoid follicles are present in biopsy samples to avoid false-negative results. Monoclonal antibodies known to recognize specific immune cell subsets present in lymphoid tissues of sheep were tested for cross-reactivity with cervine RAMALT and mesenteric lymph nodes (MLNs) preserved in zinc salts fixative. The distribution of cells expressing CD3, CD4, CD79, CD21 and class II molecules of the major histocompatibility complex was determined in these tissues. Cells of each immunophenotype had similar distributions in RAMALT and MLNs and these distributions were similar to those reported previously for sheep and cattle. The identification and validation of cervine lymphoid follicle cell markers (CD79 and CD21) may allow reduction in false-negative results during diagnosis of CWD by ELISA. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites. PMID:26904042

  8. Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review.

    Science.gov (United States)

    Dong, Yonghui; Li, Bin; Malitsky, Sergey; Rogachev, Ilana; Aharoni, Asaph; Kaftan, Filip; Svatoš, Aleš; Franceschi, Pietro

    2016-01-01

    Mass spectrometry imaging (MSI) is a mass spectrometry based molecular ion imaging technique. It provides the means for ascertaining the spatial distribution of a large variety of analytes directly on tissue sample surfaces without any labeling or staining agents. These advantages make it an attractive molecular histology tool in medical, pharmaceutical, and biological research. Likewise, MSI has started gaining popularity in plant sciences; yet, information regarding sample preparation methods for plant tissues is still limited. Sample preparation is a crucial step that is directly associated with the quality and authenticity of the imaging results, it therefore demands in-depth studies based on the characteristics of plant samples. In this review, a sample preparation pipeline is discussed in detail and illustrated through selected practical examples. In particular, special concerns regarding sample preparation for plant imaging are critically evaluated. Finally, the applications of MSI techniques in plants are reviewed according to different classes of plant metabolites.

  9. A method for the determination of potassium concentration in organic tissue samples

    International Nuclear Information System (INIS)

    Maciel, A.C.A.

    1976-12-01

    An original method has been developed to detect small variations of potassium in several samples of organic tissue. These variations are relative to elements that are biologically representative, such as carbon, oxygen, and nitrogen. The samples are irradiated with a beam of protons from a Van de Graaff accelerator (4MV). Vacancies are created in the K-shell of potassium, and x-rays are emitted when these vacancies are filled with outer electrons. These X-rays and the protons elastically scattered by the nuclei of carbon, nitrogen and oxygen are detected and their energy spectra are analysed by computer programs especially elaborated for this purpose. A technique for routine preparation of samples in the laboratory was developed including the production of aluminum support layers, and the preparation of organic tissue samples with a low temperature microtome. The unique features of this method are that it does not destroy the tissue, permitting further analysis with the microscope, and the normalization of the amount of potassium using other elements (C,O,N) instead of the total mass of the sample. (Author) [pt

  10. Gamma Imaging-Guided Minimally Invasive Breast Biopsy: Initial Clinical Experience.

    Science.gov (United States)

    Brem, Rachel F; Mehta, Anita K; Rapelyea, Jocelyn A; Akin, Esma A; Bazoberry, Adriana M; Velasco, Christel D

    2018-03-01

    The purpose of this study was to evaluate our initial experience with gamma imaging-guided vacuum-assisted breast biopsy in women with abnormal findings. A retrospective review of patients undergoing breast-specific gamma imaging (BSGI), also known as molecular breast imaging (MBI), between April 2011 and October 2015 found 117 nonpalpable mammographically and sonographically occult lesions for which gamma imaging-guided biopsies were recommended. Biopsy was performed with a 9-gauge vacuum-assisted device with subsequent placement of a titanium biopsy site marker. Medical records and pathologic findings were evaluated. Of the 117 biopsies recommended, 104 were successful and 13 were canceled. Of the 104 performed biopsies, 32 (30.8%) had abnormal pathologic findings. Of those 32 biopsies, nine (28.1%) found invasive cancers, six (18.8%) found ductal carcinoma in situ (DCIS), and 17 (53.1%) found high-risk lesions. Of the 17 high-risk lesions, there were three (17.6%) lobular carcinomas in situ, five (29.4%) atypical ductal hyperplasias, two (11.8%) atypical lobular hyperplasias, one (5.9%) flat epithelial atypia, and six (35.3%) papillomas. Two cases of atypical ductal hyperplasia were upgraded to DCIS at surgery. The overall cancer detection rate for gamma imaging-guided biopsy was 16.3%. In this study, gamma imaging-guided biopsy had a positive predictive value of total successful biopsies of 16.3% for cancer and 30.8% for cancer and high-risk lesions. Gamma imaging-guided biopsy is a viable approach to sampling BSGI-MBI-detected lesions without sonographic or mammographic correlate. Our results compare favorably to those reported for MRI-guided biopsy.

  11. The Expression of Adipogenic Genes in Adipose Tissues of Feedlot Steers Fed Supplementary Palm Oil or Soybean Oil.

    Science.gov (United States)

    Choi, Seong Ho; Park, Sung Kwon; Choi, Chang Weon; Li, Xiang Zi; Kim, Kyoung Hoon; Kim, Won Young; Jeong, Joon; Johnson, Bradley J; Zan, Linsen; Smith, Stephen B

    2016-03-01

    We hypothesized that supplementing finishing diets with palm oil would promote adipogenic gene expression and stearoyl-CoA desaturase (SCD) gene expression in subcutaneous (s.c.) and intramuscular (i.m.) adipose tissues of feedlot steers. Eighteen Angus and Angus crossbred steers were assigned to three groups of 6 steers and fed a basal diet (control), with 3% palm oil, or with 3% soybean oil, for 70 d, top-dressed daily. Tailhead s.c. adipose tissue was obtained by biopsy at 14 d before the initiation of dietary treatments and at 35 d of dietary treatments. At slaughter, after 70 d of dietary treatment, tailhead s.c. adipose tissue and i.m. adipose tissue were obtained from the longissimus thoracis muscle. Palm oil increased plasma palmitic acid and soybean oil increased plasma linoleic acid and α-linolenic acid relative to the initial sampling time. Expression of AMP-activated protein kinase alpha (AMPKα) and peroxisome proliferator-activated receptor gamma (PPARγ) increased between the initial and intermediate biopsies and declined thereafter (poil decreased (p = 0.01) PPARγ gene expression at the intermediate sample time. At the terminal sample time, PPARγ and SCD gene expression was less in i.m. adipose tissue than in s.c. adipose tissue (ppalm oil-fed steers than in control steers (p = 0.04) and CCAAT enhancer binding protein-beta (CEBPβ) gene expression was less in s.c. and i.m. adipose tissues of palm oil-fed steers than in soybean oil-fed steers (poil decreased SCD gene expression in s.c. adipose tissue (p = 0.05); SCD gene expression in palm oil-fed steers was intermediate between control and soybean oil-fed steers. Contrary to our original hypothesis, palm oil did not promote adipogenic gene expression in s.c. and i.m. adipose tissue.

  12. Relationship between reflection spectra of breast adipose tissue with histologic grade

    Science.gov (United States)

    Muñoz Morales, Aarón; Vázquez Y Montiel, Sergio; Reigosa, Aldo

    2011-08-01

    Optical spectroscopy allows the characterization, recognition and differentiation of subcutaneous tissues healthy and no-healthy, to facilitate the diagnosis or early detection for breast cancer are studied white adipose tissue by the subcutaneous region with the help of the diffuse reflection spectroscopy in the visible areas (400 to 700 nm) of electromagnetic spectrum for them using a spectrometer portable of integrating sphere, Hunter lab Model Mini-Scan. The problem to be solved for cancer detection by optical techniques is to find the solution to the inverse problem of scattering of radiation in tissue where it is necessary to solve the equation of energy transfer. us through the trigonometric interpolation and by the data adjustment by least squares using Fourier series expansion to parameterize the spectral response curves of each sample of breast adipose tissue then correlated with histological grades established by the optical biopsy for each one of the samples, allowing use this technique to the study of anomalies in White Adipose Tissue Breast, changes are evident in the spectral response for Breast Adipose Tissue carcinogens with respect to healthy tissues and for the different histological grades.

  13. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  14. TU-CD-BRB-12: Radiogenomics of MRI-Guided Prostate Cancer Biopsy Habitats

    Energy Technology Data Exchange (ETDEWEB)

    Stoyanova, R; Lynne, C; Abraham, S; Patel, M; Jorda, M; Kryvenko, O; Ishkanian, A; Abramowitz, M; Pollack, A [University of Miami, Miami, FL (United States); Tachar, M; Erho, N; Buerki, C; Lam, L; Davicioni, E [GenomeDx Biosciences Inc., Vancouver, British Columbia (Canada)

    2015-06-15

    Purpose: Diagnostic prostate biopsies are subject to sampling bias. We hypothesize that quantitative imaging with multiparametric (MP)-MRI can more accurately direct targeted biopsies to index lesions associated with highest risk clinical and genomic features. Methods: Regionally distinct prostate habitats were delineated on MP-MRI (T2-weighted, perfusion and diffusion imaging). Directed biopsies were performed on 17 habitats from 6 patients using MRI-ultrasound fusion. Biopsy location was characterized with 52 radiographic features. Transcriptome-wide analysis of 1.4 million RNA probes was performed on RNA from each habitat. Genomics features with insignificant expression values (<0.25) and interquartile range <0.5 were filtered, leaving total of 212 genes. Correlation between imaging features, genes and a 22 feature genomic classifier (GC), developed as a prognostic assay for metastasis after radical prostatectomy was investigated. Results: High quality genomic data was derived from 17 (100%) biopsies. Using the 212 ‘unbiased’ genes, the samples clustered by patient origin in unsupervised analysis. When only prostate cancer related genomic features were used, hierarchical clustering revealed samples clustered by needle-biopsy Gleason score (GS). Similarly, principal component analysis of the imaging features, found the primary source of variance segregated the samples into high (≥7) and low (6) GS. Pearson’s correlation analysis of genes with significant expression showed two main patterns of gene expression clustering prostate peripheral and transitional zone MRI features. Two-way hierarchical clustering of GC with radiomics features resulted in the expected groupings of high and low expressed genes in this metastasis signature. Conclusions: MP-MRI-targeted diagnostic biopsies can potentially improve risk stratification by directing pathological and genomic analysis to clinically significant index lesions. As determinant lesions are more reliably

  15. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  16. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  17. Bacteriology laboratories and musculoskeletal tissue banks in Australia.

    Science.gov (United States)

    Varettas, Kerry

    2012-11-01

    In Australia, there are six Therapeutic Goods Administration-licensed clinical bacteriology laboratories providing bacterial and fungal bioburden testing of allograft musculoskeletal samples sent from 10 tissue banks. Musculoskeletal swab and/or tissue biopsy samples are collected at the time of allograft retrieval and sent to bacteriology laboratories for bioburden testing, in some cases requiring interstate transport. Bacteria and fungi may be present within the allograft at the time of retrieval or contaminated from an external source. The type of organism recovered will determine if the allograft is rejected for transplant, which may include all allografts from the same donor. Bacteriology staff also provides unpaid support of tissue banks through meeting involvement, consultations, licence-related activities, validations and research funded by their organisation and not part of any contractual agreement. Bacteriology laboratories and tissue banks must be compliant to the Code of Good Manufacturing Practice - Human Blood and Tissues and regulated by the Therapeutic Goods Administration. Clinical bacteriology laboratories also require mandatory accreditation to Standards Australia International Organisation for Standardisation (ISO) 15189:2009 medical laboratories - particular requirements for quality and competence, and may also attain Standards Australia/New Zealand Standard ISO 9001:2000 quality management systems certification. Bacteriology laboratories and musculoskeletal tissue banks are integral partners in providing safe allograft musculoskeletal tissue for transplant. © 2012 The Author. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

  18. EGFR T790M mutation testing of non-small cell lung cancer tissue and blood samples artificially spiked with circulating cell-free tumor DNA: results of a round robin trial.

    Science.gov (United States)

    Fassunke, Jana; Ihle, Michaela Angelika; Lenze, Dido; Lehmann, Annika; Hummel, Michael; Vollbrecht, Claudia; Penzel, Roland; Volckmar, Anna-Lena; Stenzinger, Albrecht; Endris, Volker; Jung, Andreas; Lehmann, Ulrich; Zeugner, Silke; Baretton, Gustavo; Kreipe, Hans; Schirmacher, Peter; Kirchner, Thomas; Dietel, Manfred; Büttner, Reinhard; Merkelbach-Bruse, Sabine

    2017-10-01

    The European Commision (EC) recently approved osimertinib for the treatment of adult patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC) harboring EGFR T790M mutations. Besides tissue-based testing, blood samples containing cell-free circulating tumor DNA (ctDNA) can be used to interrogate T790M status. Herein, we describe the conditions and results of a round robin trial (RRT) for T790M mutation testing in NSCLC tissue specimens and peripheral blood samples spiked with cell line DNA mimicking tumor-derived ctDNA. The underlying objectives of this two-staged external quality assessment (EQA) approach were (a) to evaluate the accuracy of T790M mutations testing across multiple centers and (b) to investigate if a liquid biopsy-based testing for T790M mutations in spiked blood samples is feasible in routine diagnostic. Based on a successfully completed internal phase I RRT, an open RRT for EGFR T790M mutation testing in tumor tissue and blood samples was initiated. In total, 48 pathology centers participated in the EQA. Of these, 47 (97.9%) centers submitted their analyses within the pre-defined time frame and 44 (tissue), respectively, 40 (plasma) successfully passed the test. The overall success rates in the RRT phase II were 91.7% (tissue) and 83.3% (blood), respectively. Thirty-eight out of 48 participants (79.2%) successfully passed both parts of the RRT. The RRT for blood-based EGFR testing initiated in Germany is, to the best of our knowledge, the first of his kind in Europe. In summary, our results demonstrate that blood-based genotyping for EGFR resistance mutations can be successfully integrated in routine molecular diagnostics complementing the array of molecular methods already available at pathology centers in Germany.

  19. Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

    International Nuclear Information System (INIS)

    Braak, Sicco J.; Herder, Gerarda J. M.; Heesewijk, Johannes P. M. van; Strijen, Marco J. L. van

    2012-01-01

    Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm −2 , and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

  20. Right atrial and right ventricular ultrasound-guided biopsy technique in standing horses.

    Science.gov (United States)

    Decloedt, A; de Clercq, D; Ven, S; van der Vekens, N; Chiers, K; van Loon, G

    2016-05-01

    Endomyocardial biopsies could be a valuable tool in equine cardiology for diagnosing myocardial disease, which is probably underdiagnosed in horses because of lack of specific diagnostic measures and limitations of currently available diagnostic methods. To describe a technique for serial right atrial and right ventricular endomyocardial biopsy in standing horses using a percutaneous approach through the jugular vein. Prospective study. Biopsy was performed in 10 healthy standing horses sedated with detomidine, under continuous electrocardiography monitoring. A 10 cm (n = 6), 45 cm (n = 1) or 98 cm (n = 3) introducer sheath was inserted into the right jugular vein. Under echocardiographic guidance, a biopsy forceps was introduced through the sheath into the right ventricle and right atrium and endomyocardial biopsies were acquired. In all horses, 3 right ventricular biopsies were obtained from the right ventricular apex and 3 right atrial biopsies were obtained from the dorsal right atrial wall near the tuberculum intervenosum. The presence of myocardial tissue was confirmed by histology. All horses showed atrial and ventricular premature depolarisations associated with acquisition of the biopsies. In 9 horses, the arrhythmia disappeared after retraction of the forceps and introducer sheath. In one horse, ventricular premature depolarisations disappeared only after 8 h. No other complications were observed. Endomyocardial biopsy of the right atrium and right ventricle could be performed in standing horses using a percutaneous approach through the jugular vein and was not associated with complications other than temporary arrhythmias. This technique may be useful for research purposes or as a diagnostic tool, although further research is needed to establish the safety of the technique in clinical patients with myocardial disease. © 2015 EVJ Ltd.

  1. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  2. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  3. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  4. Histology of Testicular Biopsies Obtained for Experimental Fertility Preservation Protocol in Boys with Cancer.

    Science.gov (United States)

    Pietzak, Eugene J; Tasian, Gregory E; Tasian, Sarah K; Brinster, Ralph L; Carlson, Claire; Ginsberg, Jill P; Kolon, Thomas F

    2015-11-01

    Cryopreservation of testicular tissue with subsequent reimplantation after therapy has the potential to preserve fertility for prepubertal boys with cancer. We present the histology and feasibility of testicular tissue procurement for this novel approach. We performed a prospective cohort study of boys at significant risk for treatment associated gonadotoxicity who were eligible for an experimental research protocol between 2008 and 2011. Open testicular biopsy was performed while the patients were anesthetized for another treatment related procedure. Half of the specimen was reserved for cryopreservation, while the other half was used for research purposes. Semithin sections of the biopsy specimens were evaluated for histological features and compared to age adjusted reference values. A total of 34 boys underwent biopsy between March 2008 and October 2011. Of the patients 29 had solid tumors and 5 underwent hematopoietic stem cell transplantation for benign disease. A total of 27 patients had adequate tissue for histological analysis. Median patient age was 8.7 years (IQR 2.2 to 11.5). All children had either normal (81.5% of patients) or increased (18.5%) numbers of germ cells per tubule for their age. However, 5 of 26 patients (19%) older than 6 months had no evidence of adult dark spermatogonia and 9 of 16 (56%) older than 6 years had no evidence of primary spermatocytes on biopsy, which would be expected based on age norms. These findings are suggestive of abnormal germ cell maturation. The preliminary histological findings of abnormal spermatogenesis maturation in the testes of prepubertal boys with cancer warrants further investigation. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Gleasons grade was (3+3. AMACR showed a sensitivity of 93% and a specificity of 97%. It had a positive predictive value of 0.97 and a negative predictive value of 0.94. Basal cell marker, p63 showed absent staining in all the 74 cases. CONCLUSIONS With the advent of prostate specific antigen serum screening and routine use of transrectal ultrasonography, there is a manifold increase in early detection of prostate adenocarcinomas. 18-gauge needle prostate biopsy under transrectal ultrasound guidance is a preferred method for detection of adenocarcinoma because it is associated with low morbidity and it provides information regarding the grade and extent of carcinoma. However, prostate adenocarcinoma has a number of morphological mimics with various architectural patterns. Immunohistochemistry plays a major role in overcoming diagnostic dilemmas encountered due to the presence of morphological and cytological equivocal features in small volume biopsies. To conclude, in morphologically equivocal glandular architectural patterns and cytological features, combination of immunostains highlighting the basal cells and prostate cancer associated marker can help the pathologist to arrive to a diagnosis on the limited amount of tissue available at his disposal. However, applications of both the immunostains have their inherent limitations.

  6. Endoscopic trans-nasal approach for biopsy of orbital tumors using image-guided neuro-navigation system

    International Nuclear Information System (INIS)

    Sieskiewicz, A.; Mariak, Z.; Rogowski, M.; Lyson, T.

    2008-01-01

    Histopathological diagnosis of intraorbital tumors is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumors. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumors and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumors and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue. (author)

  7. Percutaneous Native Renal Biopsy Adequacy: A Successful Interdepartmental Quality Improvement Activity

    Directory of Open Access Journals (Sweden)

    Laurette Geldenhuys

    2015-03-01

    Full Text Available Background: An adequate renal biopsy is essential for diagnosis and treatment of medical renal disease. Objective: We evaluated two initiatives to improve adequacy of renal biopsy samples at our centre. Design: Retrospective determination of renal biopsy adequacy. Setting: Queen Elizabeth II Health Sciences Centre. Patients: Patients undergoing medical renal biopsies. Measurements: Renal biopsy adequacy. Methods: The first initiative was to restrict the performance of biopsies to a smaller group of radiologists and to include a comment on biopsy adequacy in every pathology report. The second initiative was to introduce on-site adequacy assessment by a medical laboratory technologist. Native renal and allograft biopsy adequacies were calculated for three periods: 1 baseline, October 2005 to September 2006; 2 after implementation of the first initiative, January 2007 to September 2011; and 3 after implementation of the second initiative, October 2011 to September 2012. A subset of native renal biopsies was examined to determine if there was a relationship between adequacy and number of passes. Results: The percentages of adequate native renal biopsies during the first, second, and third periods were 31%, 72% and 90%, respectively. This represents a significant increase (40%, p < 0.0001 in adequacy following the first initiative, and another significant increase (18%, p = 0.0003 following the second initiative. The percentages of adequate renal allograft biopsies during the first, second, and third periods were 75%, 56% and 69%, respectively. These changes in adequacy were not statistically significant. In the subset of native renal biopsies examined, a biopsy comprising more than three cores was not associated with increase in adequacy. Limitations: The most important limitation is the lack of generally accepted and applied adequacy criteria limiting generalizability of our findings. Conclusions: Restricting the performance of biopsies to

  8. Optical Biopsy Using Tissue Spectroscopy and Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Norman S Nishioka

    2003-01-01

    Full Text Available ‘Optical biopsy’ or ‘optical diagnostics’ is a technique whereby light energy is used to obtain information about the structure and function of tissues without disrupting them. In fluorescence spectroscopy, light energy (usually provided by a laser is used to excite tissues and the resulting fluorescence provides information about the target tissue. Its major gastrointestinal application has been in the evaluation of colonic polyps, in which it can reliably distinguish malignant from benign lesions. Optical coherence tomography (OCT has been used in the investigation of Barrett’s epithelium (and dysplasia, although a variety of other applications are feasible. For example, OCT could assist in the identification and staging of mucosal and submucosal neoplasms, the grading of inflammation in the stomach and intestine, the diagnosis of biliary tumours and the assessment of villous architecture. OCT differs from endoscopic ultrasound, a complementary modality, in that it has a much higher resolution but lesser depth of penetration. The images correlate with the histopathological appearance of tissues, and the addition of Doppler methods may enable it to evaluate the vascularity of tumours and the amount of blood flow in varices. Refinements in these new optical techniques will likely make them valuable in clinical practice, although their specific roles have yet to be determined.

  9. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  10. Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

    Directory of Open Access Journals (Sweden)

    Jay Patel

    2008-01-01

    Full Text Available Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23, small atypical acinar proliferation (21 or no evidence of malignancy (43. QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in

  11. On Predicting lung cancer subtypes using ‘omic’ data from tumor and tumor-adjacent histologically-normal tissue

    International Nuclear Information System (INIS)

    Pineda, Arturo López; Ogoe, Henry Ato; Balasubramanian, Jeya Balaji; Rangel Escareño, Claudia; Visweswaran, Shyam; Herman, James Gordon; Gopalakrishnan, Vanathi

    2016-01-01

    Adenocarcinoma (ADC) and squamous cell carcinoma (SCC) are the most prevalent histological types among lung cancers. Distinguishing between these subtypes is critically important because they have different implications for prognosis and treatment. Normally, histopathological analyses are used to distinguish between the two, where the tissue samples are collected based on small endoscopic samples or needle aspirations. However, the lack of cell architecture in these small tissue samples hampers the process of distinguishing between the two subtypes. Molecular profiling can also be used to discriminate between the two lung cancer subtypes, on condition that the biopsy is composed of at least 50 % of tumor cells. However, for some cases, the tissue composition of a biopsy might be a mix of tumor and tumor-adjacent histologically normal tissue (TAHN). When this happens, a new biopsy is required, with associated cost, risks and discomfort to the patient. To avoid this problem, we hypothesize that a computational method can distinguish between lung cancer subtypes given tumor and TAHN tissue. Using publicly available datasets for gene expression and DNA methylation, we applied four classification tasks, depending on the possible combinations of tumor and TAHN tissue. First, we used a feature selector (ReliefF/Limma) to select relevant variables, which were then used to build a simple naïve Bayes classification model. Then, we evaluated the classification performance of our models by measuring the area under the receiver operating characteristic curve (AUC). Finally, we analyzed the relevance of the selected genes using hierarchical clustering and IPA® software for gene functional analysis. All Bayesian models achieved high classification performance (AUC > 0.94), which were confirmed by hierarchical cluster analysis. From the genes selected, 25 (93 %) were found to be related to cancer (19 were associated with ADC or SCC), confirming the biological relevance of our

  12. Optical biopsy - a new armamentarium to detect disease using light

    Science.gov (United States)

    Pu, Yang; Alfano, Robert R.

    2015-03-01

    Optical spectroscopy has been considered a promising method for cancer detection for past thirty years because of its advantages over the conventional diagnostic methods of no tissue removal, minimal invasiveness, rapid diagnoses, less time consumption and reproducibility since the first use in 1984. It offers a new armamentarium. Human tissue is mainly composed of extracellular matrix of collagen fiber, proteins, fat, water, and epithelial cells with key molecules in different structures. Tissues contain a number of key fingerprint native endogenous fluorophore molecules, such as tryptophan, collagen, elastin, reduced nicotinamide adenine dinucleotide (NADH), flavin adenine dinucleotide (FAD) and porphyrins. It is well known that abnormalities in metabolic activity precede the onset of a lot of main diseases: carcinoma, diabetes mellitus, atherosclerosis, Alzheimer, and Parkinson's disease, etc. Optical spectroscopy may help in detecting various disorders. Conceivably the biochemical or morphologic changes that cause the spectra variations would appear earlier than the histological aberration. Therefore, "optical biopsy" holds a great promise as clinical tool for diagnosing early stage of carcinomas and other deceases by combining with available photonic technology (e.g. optical fibers, photon detectors, spectrographs spectroscopic ratiometer, fiber-optic endomicroscope and nasopharyngoscope) for in vivo use. This paper focuses on various methods available to detect spectroscopic changes in tissues, for example to distinguish cancerous prostate tissues and/or cells from normal prostate tissues and/or cells. The methods to be described are fluorescence, stokes shift, scattering, Raman, and time-resolved spectroscopy will be reviewed. The underlying physical and biological basis for these optical approaches will be discussed with examples. The idea is to present some of the salient works to show the usefulness and methods of Optical Biopsy for cancer detection and

  13. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  14. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  15. In vitro assessment of Tribulus terrestris aqueous extract and Benzoxacin fraction against Helicobacter pylori isolates from biopsy samples of Iranian patients

    Directory of Open Access Journals (Sweden)

    Mojdeh Hakemi vala

    2014-02-01

    Full Text Available Background & Objectives:  Helicobacter pylori (Hp is related to gastritis, gastric ulcer, duodenal ulcer, and mucosal carcinoma. Emergence of multidrug resistant Hp strains encouraged the researchers to find new effective drugs. Especially medicinal herbs and plants which usually shows less side effects. The aim of this study was in vitro assessment of anti Hp activity of total extract of Tribulus terrestris (T. terrestris Benzoxacin, a local Iranian medicinal plant and its fraction Benzoxacin.Methods: total aqueous extract of aerial parts of the plant was prepared and liquid extraction with petroleum ether was used to separate its components. LC/MS system proved the existence of Benzoxazine derivative in the water fraction and the third's fraction. Anti (Hp effects of total extract and its third fraction were examined by cup plate method and using standard MacFarland. 50 biopsy samples of antrum were detected from patients who were endoscopic candidates in Milad and Fayazbakhsh  hospitals of Tehran during 2011. All samples were isolated, diagnosed based on standard methods and biochemical tests and confirmed by PCR method for ureC gene, too.  Different dilutions (250, 500,750 and 1000 mg/ml of total extract were prepared. Clarythromycin (Clr E-test strips and an identified Hp OC1096 was used, simultaneously.Results: Of 50 biopsy samples, 12 Hp strains were isolated. Rapid urease test were positive in all expect one biopsy sample. Existence of ureC gene in all isolates were confirmed expect one strain by PCR. By cup plate method, resistant to concentrations of 1000 and 750mg/ml were detected in 50% of Hp isolates and 66.6% of them were resistant to concentrations 250 and 500 mg/ml .Also, 83.3% of Hp strains were resistant to Benzoxacin fraction. Clarythromycin sensitivity detected in 83% of Hp isolates, simultaneously.Conclusion: This study was done as a pilot study for in vitro evaluation of antibacterial effect of total extract of T

  16. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  17. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  18. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  19. Pattern of somatostatin receptors expression in normal and bladder cancer tissue samples.

    Science.gov (United States)

    Karavitakis, Markos; Msaouel, Pavlos; Michalopoulos, Vassilis; Koutsilieris, Michael

    2014-06-01

    Known risks factors for bladder cancer progression and recurrence are limited regarding their prognostic ability. Therefore identification of molecular determinants of disease progression could provide with more specific prognostic information and could be translated into new approaches for biomarker development. In the present study we evaluated, the expression patterns of somatostatin receptors 1-5 (SSTRs) in normal and tumor bladder tissues. The expression of SSTR1-5 was characterized in 45 normal and bladder cancer tissue samples using reverse transcriptase-polymerase chain reaction (RT-PCR). SSTR1 was expressed in 24 samples, SSTR2 in 15, SSTR3 in 23, SSTR4 in 16 and SSTR5 in all but one sample. Bladder cancer tissue samples expressed lower levels of SSTR3. Co-expression of SSTRs was associated with superficial disease. Our results demonstrate, for the first time, that there is expression of SSTR in normal and bladder cancer urothelium. Further studies are required to evaluate the prognostic and therapeutic significance of these findings. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  20. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  1. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  2. High grade squamous intraepithelial lesion in inmates from Ohio: cervical screening and biopsy follow-up

    Directory of Open Access Journals (Sweden)

    Rofagha Soraya

    2006-01-01

    Full Text Available Abstract Background Cervical carcinoma remains the second leading cause of cancer death in women worldwide and sexual behavior is regarded as the main contributing factor. We studied cervical cytology screening with surgical biopsy follow-up in women prisoners and compared the findings to those in the general population. Methods We reviewed 1024 conventional cervical smears, 73 cervical biopsies and 2 loop electrosurgical excision procedure (LEEP specimens referred to us from the Correctional Center in Columbus, Ohio during a 12-month period. The results were compared to 40,993 Pap smears from the general population for the same 12-month period. Results High grade squamous intraepithelial lesion (HGSIL was diagnosed in 1.3% of the cervical smears from the inmate population versus 0.6% in the general population (p < 0.01. The unsatisfactory rate was 1.6% compared to 0.3% in the general population (p < 0.01. Among the study population, follow-up tissue diagnosis was obtained in 24.3% of the abnormal cytology results (ASCUS, LGSIL, and HGSIL. Of the HGSIL Pap smears, 61.5% had a subsequent tissue diagnosis. Thirty-nine biopsies (52% of the all inmate biopsies and LEEP showed CIN II/III (cervical intraepithelial neoplasia II/III. Eight of these thirty-nine follow-up biopsies diagnosed as CIN II/III had a previous cervical cytology diagnosis of ASCUS. The average age for HGSIL was 30.5 years (S.D. = 5.7 and for low grade squamous intraepithelial lesion (LGSIL was 27.2 years (S.D. = 6.1. Conclusion A significantly higher prevalence of HGSIL cervical cytology and unsatisfactory smears was encountered in female inmates, with tissue follow-up performed in less than two thirds of the patients with HGSIL. These results are in keeping with data available in the literature suggesting that the inmate population is high-risk and may be subject to less screening and tissue follow-up than the general population. Clinicians should proceed with urgency to improve

  3. MRI/TRUS fusion software-based targeted biopsy: the new standard of care?

    Science.gov (United States)

    Manfredi, M; Costa Moretti, T B; Emberton, M; Villers, A; Valerio, M

    2015-09-01

    The advent of multiparametric MRI has made it possible to change the way in which prostate biopsy is done, allowing to direct biopsies to suspicious lesions rather than randomly. The subject of this review relates to a computer-assisted strategy, the MRI/US fusion software-based targeted biopsy, and to its performance compared to the other sampling methods. Different devices with different methods to register MR images to live TRUS are currently in use to allow software-based targeted biopsy. Main clinical indications of MRI/US fusion software-based targeted biopsy are re-biopsy in men with persistent suspicious of prostate cancer after first negative standard biopsy and the follow-up of patients under active surveillance. Some studies have compared MRI/US fusion software-based targeted versus standard biopsy. In men at risk with MRI-suspicious lesion, targeted biopsy consistently detects more men with clinically significant disease as compared to standard biopsy; some studies have also shown decreased detection of insignificant disease. Only two studies directly compared MRI/US fusion software-based targeted biopsy with MRI/US fusion visual targeted biopsy, and the diagnostic ability seems to be in favor of the software approach. To date, no study comparing software-based targeted biopsy against in-bore MRI biopsy is available. The new software-based targeted approach seems to have the characteristics to be added in the standard pathway for achieving accurate risk stratification. Once reproducibility and cost-effectiveness will be verified, the actual issue will be to determine whether MRI/TRUS fusion software-based targeted biopsy represents anadd-on test or a replacement to standard TRUS biopsy.

  4. On multielement analysis of biological samples with the aid of neutron activation

    International Nuclear Information System (INIS)

    Iyengar, G.V.

    1980-01-01

    A main objective of this study was elucidation of problems of sampling and sample preparation methods for multielement analysis of environmental and biological specimens. Another was assessment of the potentials of multielement neutron activation analysis (NAA) in environmental and biological research. In an attempt to explain the great differences in the elemental concentration ranges between biopsy and autopsy samples as reported in the literature, it was shown that post mortem changes induce great variations in the apparent elemental composition of autopsy specimens resulting in serious systematic errors. Applications of NAA to analysis of tissues of experimental animals, human tissues in health and disease, and environmental samples are illustrated with several examples. The suitability of NAA for routine analysis of elements such as Cr, Mo and Se, which are difficult to determine by other methods has been specially discussed. (author)

  5. Improving the Prediction of Prostate Cancer Overall Survival by Supplementing Readily Available Clinical Data with Gene Expression Levels of IGFBP3 and F3 in Formalin-Fixed Paraffin Embedded Core Needle Biopsy Material.

    Directory of Open Access Journals (Sweden)

    Zhuochun Peng

    Full Text Available A previously reported expression signature of three genes (IGFBP3, F3 and VGLL3 was shown to have potential prognostic value in estimating overall and cancer-specific survivals at diagnosis of prostate cancer in a pilot cohort study using freshly frozen Fine Needle Aspiration (FNA samples.We carried out a new cohort study with 241 prostate cancer patients diagnosed from 2004-2007 with a follow-up exceeding 6 years in order to verify the prognostic value of gene expression signature in formalin fixed paraffin embedded (FFPE prostate core needle biopsy tissue samples. The cohort consisted of four patient groups with different survival times and death causes. A four multiplex one-step RT-qPCR test kit, designed and optimized for measuring the expression signature in FFPE core needle biopsy samples, was used. In archive FFPE biopsy samples the expression differences of two genes (IGFBP3 and F3 were measured. The survival time predictions using the current clinical parameters only, such as age at diagnosis, Gleason score, PSA value and tumor stage, and clinical parameters supplemented with the expression levels of IGFBP3 and F3, were compared.When combined with currently used clinical parameters, the gene expression levels of IGFBP3 and F3 are improving the prediction of survival time as compared to using clinical parameters alone.The assessment of IGFBP3 and F3 gene expression levels in FFPE prostate cancer tissue would provide an improved survival prediction for prostate cancer patients at the time of diagnosis.

  6. Antemortem detection of chronic wasting disease prions in nasal brush collections and rectal biopsies from white-tailed deer by real time quaking-induced conversion

    Science.gov (United States)

    Haley, Nicholas J.; Siepker, Chris; Walter, W. David; Thomsen, Bruce V.; Greenlee, Justin J.; Lehmkuhl, Aaron D.; Richt, Jürgen a.

    2016-01-01

    Chronic wasting disease (CWD), a transmissible spongiform encephalopathy of cervids, was first documented nearly 50 years ago in Colorado and Wyoming and has since spread to cervids in 23 states, two Canadian provinces, and the Republic of Korea. The expansion of this disease makes the development of sensitive diagnostic assays and antemortem sampling techniques crucial for the mitigation of its spread; this is especially true in cases of relocation/reintroduction of farmed or free-ranging deer and elk or surveillance studies of private or protected herds, where depopulation is contraindicated. This study sought to evaluate the sensitivity of the real-time quaking-induced conversion (RT-QuIC) assay by using recto-anal mucosa-associated lymphoid tissue (RAMALT) biopsy specimens and nasal brush samples collected antemortem from farmed white-tailed deer (n = 409). Antemortem findings were then compared to results from ante- and postmortem samples (RAMALT, brainstem, and medial retropharyngeal lymph nodes) evaluated by using the current gold standard in vitro assay, immunohistochemistry (IHC) analysis. We hypothesized that the sensitivity of RT-QuIC would be comparable to IHC analysis in antemortem tissues and would correlate with both the genotype and the stage of clinical disease. Our results showed that RAMALT testing by RT-QuIC assay had the highest sensitivity (69.8%) compared to that of postmortem testing, with a specificity of >93.9%. These data suggest that RT-QuIC, like IHC analysis, is an effective assay for detection of PrPCWD in rectal biopsy specimens and other antemortem samples and, with further research to identify more sensitive tissues, bodily fluids, or experimental conditions, has potential for large-scale and rapid automated testing for CWD diagnosis.

  7. HCV-RNA quantification in liver bioptic samples and extrahepatic compartments, using the abbott RealTime HCV assay.

    Science.gov (United States)

    Antonucci, FrancescoPaolo; Cento, Valeria; Sorbo, Maria Chiara; Manuelli, Matteo Ciancio; Lenci, Ilaria; Sforza, Daniele; Di Carlo, Domenico; Milana, Martina; Manzia, Tommaso Maria; Angelico, Mario; Tisone, Giuseppe; Perno, Carlo Federico; Ceccherini-Silberstein, Francesca

    2017-08-01

    We evaluated the performance of a rapid method to quantify HCV-RNA in the hepatic and extrahepatic compartments, by using for the first time the Abbott RealTime HCV-assay. Non-tumoral (NT), tumoral (TT) liver samples, lymph nodes and ascitic fluid from patients undergoing orthotopic-liver-transplantation (N=18) or liver resection (N=4) were used for the HCV-RNA quantification; 5/22 patients were tested after or during direct acting antivirals (DAA) treatment. Total RNA and DNA quantification from tissue-biopsies allowed normalization of HCV-RNA concentrations in IU/μg of total RNA and IU/10 6 liver-cells, respectively. HCV-RNA was successfully quantified with high reliability in liver biopsies, lymph nodes and ascitic fluid samples. Among the 17 untreated patients, a positive and significant HCV-RNA correlation between serum and NT liver-samples was observed (Pearson: rho=0.544, p=0.024). Three DAA-treated patients were HCV-RNA "undetectable" in serum, but still "detectable" in all tested liver-tissues. Differently, only one DAA-treated patient, tested after sustained-virological-response, showed HCV-RNA "undetectability" in liver-tissue. HCV-RNA was successfully quantified with high reliability in liver bioptic samples and extrahepatic compartments, even when HCV-RNA was "undetectable" in serum. Abbott RealTime HCV-assay is a good diagnostic tool for HCV quantification in intra- and extra-hepatic compartments, whenever a bioptic sample is available. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. DNA damage in preserved specimens and tissue samples: a molecular assessment

    Directory of Open Access Journals (Sweden)

    Cantin Elizabeth

    2008-10-01

    Full Text Available Abstract The extraction of genetic information from preserved tissue samples or museum specimens is a fundamental component of many fields of research, including the Barcode of Life initiative, forensic investigations, biological studies using scat sample analysis, and cancer research utilizing formaldehyde-fixed, paraffin-embedded tissue. Efforts to obtain genetic information from these sources are often hampered by an inability to amplify the desired DNA as a consequence of DNA damage. Previous studies have described techniques for improved DNA extraction from such samples or focused on the effect of damaging agents – such as light, oxygen or formaldehyde – on free nucleotides. We present ongoing work to characterize lesions in DNA samples extracted from preserved specimens. The extracted DNA is digested to single nucleosides with a combination of DNase I, Snake Venom Phosphodiesterase, and Antarctic Phosphatase and then analyzed by HPLC-ESI-TOF-MS. We present data for moth specimens that were preserved dried and pinned with no additional preservative and for frog tissue samples that were preserved in either ethanol, or formaldehyde, or fixed in formaldehyde and then preserved in ethanol. These preservation methods represent the most common methods of preserving animal specimens in museum collections. We observe changes in the nucleoside content of these samples over time, especially a loss of deoxyguanosine. We characterize the fragmentation state of the DNA and aim to identify abundant nucleoside lesions. Finally, simple models are introduced to describe the DNA fragmentation based on nicks and double-strand breaks.

  9. MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

    International Nuclear Information System (INIS)

    Thompson, Scott M.; Gorny, Krzysztof R.; Jondal, Danielle E.; Rech, Karen L.; Mardini, Samir; Woodrum, David A.

    2017-01-01

    A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

  10. MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Scott M., E-mail: Thompson.scott@mayo.edu; Gorny, Krzysztof R.; Jondal, Danielle E. [Mayo Clinic College of Medicine, Department of Radiology (United States); Rech, Karen L. [Mayo Clinic College of Medicine, Department of Laboratory Medicine and Pathology (United States); Mardini, Samir [Mayo Clinic College of Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery (United States); Woodrum, David A. [Mayo Clinic College of Medicine, Division of Vascular and Interventional Radiology, Department of Radiology (United States)

    2017-01-15

    A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

  11. 11-gauge vacuum assisted directional biopsy of breast calcifications, using upright stereotactic guidance

    International Nuclear Information System (INIS)

    Nisbet, A.P.; Borthwick-Clarke, A.; Scott, N.

    2000-01-01

    To assess the use of a prototype vacuum assisted biopsy device on a standard upright mammography unit, using a slightly modified digital stereotactic add-on component. A group comprised of 42 sequential patients, who had been recalled from an asymptomatic mammographic screening programme, were studied. All 42 were recalled for assessment of small clusters of microcalcification, graded as indeterminate. Group 1 (21 patients) were biopsied using 14-gauge automated large core needle biopsy. Group 2 (21 patients) were biopsied using 11-gauge vacuum assisted biopsy. Both groups had mammographic guidance on the same upright mammographic unit (Siemens 3000), with Opdima Digital Stereotactic add-on. A total of 86% of specimen radiographs in Group 2 patients (vacuum assisted biopsy) showed successful sampling of the calcifications, compared to 62% of Group 1 patients (14-gauge automated large core biopsies). This study shows that vacuum assisted biopsy is possible using upright stereotactic mammography units. The technique shows promise as a biopsy tool, offering larger cores compared to 14-gauge automated large core biopsy, while requiring less space and lower purchase price compared to dedicated prone biopsy tables. The technique also offers access to biopsy in patients with posterior lesions and for patients who cannot tolerate prone positioning

  12. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  13. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  14. Tangential Biopsy Thickness versus Lesion Depth in Longitudinal Melanonychia: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Nilton Di Chiacchio

    2012-01-01

    Full Text Available Longitudinal melanonychia can be caused by melanocyte activation (hypermelanosis or proliferation (lentigo, nevus or melanoma. Histopathologic examination is mandatory for suspicious cases of melanomas. Tangential biopsy of the matrix is an elegant technique avoiding nail plate dystrophy, but it was unknown whether the depth of the sample obtained by this method is adequate for histopathologic diagnosis. Twenty-two patients with longitudinal melanonychia striata were submitted to tangential matrix biopsies described by Haneke. The tissue was stained with hematoxylin-eosin and the specimens were measured at 3 distinct points according to the total thickness: largest (A, intermediate (B and narrowest (C then divided into 4 groups according to the histopathologic diagnosis (G1: hypermelanosis; G2: lentigos; G3: nevus; G4: melanoma. The lesions were measured using the same method. The mean specimen/lesion thickness measure values for each group was: G1: 0,59/0,10 mm, G2: 0,67/0,08 mm, G3: 0,52/0,05 mm, G4: 0,58/0,10 mm. The general average thickness for all the specimens/lesions was 0,59/0,08 mm. We concluded that the tangential excision, for longitudinal melanonychia, provides an adequate material for histopathological diagnosis.

  15. Use of CT-guided fine needle aspiration biopsy in epidermal growth factor receptor mutation analysis in patients with advanced lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping; Wang, Hai-Yan; Zhang, Jin; Feng, Yong (Dept. of Radiology, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China)), email: yipingzhuang2010@sina.com; Shi, Mei-Qi (Dept. of Chemotherapy, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China))

    2011-12-15

    Background. The safety of using a cutting needle when performing a core-needle biopsy is of major concern, in particular for small lung tumors or tumors near the hilum. Purpose. To investigate the usefulness of CT-guided fine needle aspiration biopsy (FNAB) of the lung in obtaining tumor tissue for epidermal growth factor receptor (EGFR) mutation analysis in advanced lung cancer patients. Material and Methods. Forty-three patients with stage IIIB-IV lung cancer were enrolled. In all patients, CT-guided FNAB was performed using an 18-gauge or 20-gauge Chiba aspiration needle for histology diagnosis and EGFR mutation analysis. Complications associated with CT-guided FNAB were observed, and the specimen mutational assessments were recorded. Results. The obtained tumor samples ranged from 0.5-1.5 cm in length and were adequate for histological and DNA analyses in all patients. No patient had a pneumothorax or hemoptysis. Minor needle tract bleeding appeared in eight patients. Mutation analysis was satisfactorily demonstrated in 23 mutations and 20 non-mutations. Ten and 13 mutations were identified by 18-gauge and 20-gauge needle biopsies, respectively. EFGR mutations, including 12 cases of EGFR exon 19 deletion and 11 cases of exon 21 point mutation, were present in 21 patients with adenocarcinomas, one with squamous cell carcinoma, and one with undifferentiated carcinoma. Conclusion. CT-guided FNAB is a feasible and safe technique for obtaining lung tumor tissues for EGFR gene mutation analysis

  16. [Hospitalization rate in relation to severe complications of transrectal prostate biopsy: About 2715 patients biopsied].

    Science.gov (United States)

    Tamarelle, B; Perrin, P; Devonec, M; Paparel, P; Ruffion, A

    To identify hospitalizations directly related to a complication occurring within 30 days following a transrectal prostate biopsy (PBP). Overall hospitalization rates, mortality rates, potential predisposing factors for complications. Single-center study including all patients who underwent PBP between January 2005 and January 2012. Any hospitalization occurring within 30 days of the PBP for urgent motive was considered potentially attributable to biopsy. We identified the reason for hospitalization with direct complications (urinary infection or fever, rectal bleeding, bladder caillotage, retention) and indirect (underlying comorbidities decompensation) of the biopsy. The contributing factors were anticoagulant or antiplatelet treatment well as waning immunity factors (corticosteroid therapy, HIV, chemotherapy or immunodulateur). Among 2715 men who underwent PBP, there were 120 (4.4%) hospitalizations including 28 (1.03%) caused by the biopsy. Twenty-five (0.92%) were related to a direct complication of biopsy: 14 (56%) for urinary tract infection or fever including 1 hospitalization in intensive care, 5 (20%) for rectal bleeding which required several transfusions 1, 10 (40%) urinary retention and 3 (0.11%) for an indirect complication (2 coronary syndromes and 1 respiratory failure). Several direct complications were associated in 3 cases. Only two hospitalizations associated with rectal bleeding were taking an antiplatelet or anticoagulant. There was no association between hospitalization for urinary tract infections and a decreased immune status. The first death observed in our study occurred at D31 of pulmonary embolism (advanced metastatic patient with bladder cancer). Twenty (60.6%) patients urgently hospitalized did not have prostate cancer. Within this large sample of patients the overall rate of hospitalization due to the realization of a PBP was 1%. It has not been found predictive of complications leading to hospitalization. 4. Copyright © 2016

  17. Correlation study of trace metals in malignant and normal breast tissues by AAS technique

    International Nuclear Information System (INIS)

    Rahman, S.

    2012-01-01

    The study reports the application of atomic absorption spectrophotometry (AAS) for quantification of Fe, Cu and Zn in forty one formalin-fixed biopsy breast carcinoma tissue and adjoining fifteen normal tissue samples. These tissues samples were of category two breast carcinoma patients and of normal subjects. The qualitative comparison between the elements levels measured in the two types of specimens suggests significant elevation of these metals in the histopathological samples of carcinoma tissue. The samples were collected from women aged 19-51 years. Most of the patients belong to urban areas of Pakistan and middle to high socioeconomic status with the exception of few. Findings of study depicts that these elements have an important role in the initiation and development of carcinoma as consistent pattern of elevation for Fe, Cu and Zn was observed. The results showed the excessive accumulation of Fe (166.9 mg/L) in tissue samples of breast carcinoma patients (p < 0.01) than that in normal tissues samples (23.5 mg/L). In order to validate our method of analysis certified reference material Muscle Tissue Lyophilised (IAEA) MA-M-2/TM was analyzed for Fe, Cu and Zn. Determined concentrations were in good agreement with certified levels. The concentration distribution of trace elements Cu, Zn and Fe measured in the malignant tissues were found to be higher when compared to benign tissues, indicating the involvement of these metals in the breast malignancy. Results also indicate that excess iron may play a role in breast carcinogenesis. (Orig./A.B.)

  18. A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

    Science.gov (United States)

    Mitra, Jhimli; Srikantha, Abhilash; Sidibé, Désiré; Martí, Robert; Oliver, Arnau; Lladó, Xavier; Ghose, Soumya; Vilanova, Joan C.; Comet, Josep; Meriaudeau, Fabrice

    2012-02-01

    This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to perform an analysis based on shape and information theory to reach close enough to the actual MR slice as validated by experts. The Bhattacharyya distance is used to find point correspondences between shape-context representations of the prostate contours. Thereafter, Chi-square distance is used to find out those MR slices where the prostates closely match with that of the TRUS slice. Normalized Mutual Information (NMI) values of the TRUS slice with each of the axial MR slices are computed after rigid alignment and consecutively a strategic elimination based on a set of rules between the Chi-square distances and the NMI leads to the required MR slice. We validated our method for TRUS axial slices of 15 patients, of which 11 results matched at least one experts validation and the remaining 4 are at most one slice away from the expert validations.

  19. Cost Analysis of Channeled, Distal Chip Laryngoscope for In-office Laryngopharyngeal Biopsies.

    Science.gov (United States)

    Marcus, Sonya; Timen, Micah; Dion, Gregory R; Fritz, Mark A; Branski, Ryan C; Amin, Milan R

    2018-02-19

    Given that financial considerations play an increasingly prominent role in clinical decision-making, we sought (1) to determine the cost-effectiveness of in-office biopsy for the patient, the provider, and the health-care system, and (2) to determine the diagnostic accuracy of in-office biopsy. Retrospective, financial analyses were performed. Patients who underwent in-office (Current Procedural Terminology Code 31576) or operative biopsy (CPT Code 31535) for laryngopharyngeal lesions were included. Two financial analyses were performed: (1) the average cost of operating room (OR) versus in-office biopsy was calculated, and (2) a break-even analysis was calculated to determine the cost-effectiveness of in-office biopsy for the provider. In addition, the diagnostic accuracy of in-office biopsies and need for additional biopsies or procedures was recorded. Of the 48 patients included in the current study, 28 underwent in-office biopsy. A pathologic sample was obtained in 26 of 28 (92.9%) biopsies performed in the office. Of these patients, 16 avoided subsequent OR procedures. The average per patient cost was $7000 and $11,000 for in-office and OR biopsy, respectively. Break-even analysis demonstrated that the provider could achieve a profit 2 years after purchase of the necessary equipment. In-office laryngopharyngeal biopsies are accurate and, overall, more cost-effective than OR biopsies. Purchase of the channeled, distal chip laryngoscope and biopsy forceps to perform in-office biopsies can be profitable for a provider with a videolaryngoscopy tower. In-office biopsy should be considered the initial diagnostic tool for suspected laryngopharyngeal malignancies noted on videolaryngoscopy. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. Pathology in a tube step 2: simple rapid fabrication of curved circular cross section millifluidic channels for biopsy preparation/3D imaging towards pancreatic cancer detection and diagnosis

    Science.gov (United States)

    Das, Ronnie; Burfeind, Chris W.; Lim, Saniel D.; Patle, Shubham; Seibel, Eric J.

    2018-02-01

    3D pathology is intrinsically dependent on 3D microscopy, or the whole tissue imaging of patient tissue biopsies (TBs). Consequently, unsectioned needle specimens must be processed whole: a procedure which cannot necessarily be accomplished through manual methods, or by retasking automated pathology machines. Thus "millifluidic" devices (for millimeter-scale biopsies) are an ideal solution for tissue handling/preparation. TBs are large, messy and a solid-liquid mixture; they vary in material, geometry and structure based on the organ biopsied, the clinician skill and the needle type used. As a result, traditional microfluidic devices are insufficient to handle such mm-sized samples and their associated fabrication techniques are impractical and costly with respect to time/efficiency. Our research group has devised a simple, rapid fabrication process for millifluidic devices using jointed skeletal molds composed of machined, reusable metal rods, segmented rods and stranded wire as structural cores; these cores are surrounded by Teflon outer housing. We can therefore produce curving, circular-cross-section (CCCS) millifluidic channels in rapid fashion that cannot normally be achieved by microfabrication, micro-/CNC-machining, or 3D printing. The approach has several advantages. CLINICAL: round channels interface coring needles. PROCESSING: CCCS channels permit multi-layer device designs for additional (processing, monitoring, testing) stages. REUSABILITY: for a biopsy/needle diameter, molding (interchangeable) components may be produced one-time then reused for other designs. RAPID: structural cores can be quickly removed due to Teflon®'s ultra-low friction; housing may be released with ethanol; PDMS volumes cure faster since metal skeleton molds conduct additional heat from within the curing elastomer.