WorldWideScience

Sample records for tip lens technique

  1. Surface tension-induced high aspect-ratio PDMS micropillars with concave and convex lens tips

    KAUST Repository

    Li, Huawei

    2013-04-01

    This paper reports a novel method for the fabrication of 3-dimensional (3D) Polydimethylsiloxane (PDMS) micropillars with concave and convex lens tips in a one-step molding process, using a CO2 laser-machined Poly(methyl methacrylate) (PMMA) mold with through holes. The PDMS micropillars are 4 mm high and have an aspect ratio of 251. The micropillars are formed by capillary force drawing up PDMS into the through hole mold. The concave and convex lens tips of the PDMS cylindrical micropillars are induced by surface tension and are controllable by changing the surface wetting properties of the through holes in the PMMA mold. This technique eliminates the requirements of expensive and complicated facilities to prepare a 3D mold, and it provides a simple and rapid method to fabricate 3D PDMS micropillars with controllable dimensions and tip shapes. © 2013 IEEE.

  2. Surface tension-induced high aspect-ratio PDMS micropillars with concave and convex lens tips

    KAUST Repository

    Li, Huawei; Fan, Yiqiang; Yi, Ying; Foulds, Ian G.

    2013-01-01

    This paper reports a novel method for the fabrication of 3-dimensional (3D) Polydimethylsiloxane (PDMS) micropillars with concave and convex lens tips in a one-step molding process, using a CO2 laser-machined Poly(methyl methacrylate) (PMMA) mold with through holes. The PDMS micropillars are 4 mm high and have an aspect ratio of 251. The micropillars are formed by capillary force drawing up PDMS into the through hole mold. The concave and convex lens tips of the PDMS cylindrical micropillars are induced by surface tension and are controllable by changing the surface wetting properties of the through holes in the PMMA mold. This technique eliminates the requirements of expensive and complicated facilities to prepare a 3D mold, and it provides a simple and rapid method to fabricate 3D PDMS micropillars with controllable dimensions and tip shapes. © 2013 IEEE.

  3. ZBrush Professional Tips and Techniques

    CERN Document Server

    Gaboury, Paul

    2012-01-01

    Learn to work effectively and creatively with all versions of ZBrush! ZBrush is used by top artists in Hollywood to model and sculpt characters in such films as Avatar, Iron Man, and Pirates of the Caribbean. In addition, this amazing technology is also used in jewelry design, forensic science, aerospace, video games, toy creation, and the medical field. Written by Pixologic's in-house ZBrush expert Paul Gaboury, this full-color, beautifully illustrated guide provides you with the ultimate tips and tricks to maximize your use of all versions of ZBrush. Reveals numerous little-known tips and tr

  4. Observation of Biological Tissues Using Common Path Optical Coherence Tomography with Gold Coated Conical Tip Lens Fiber

    International Nuclear Information System (INIS)

    Taguchi, K; Sugiyama, J; Totsuka, M; Imanaka, S

    2012-01-01

    In this paper, we proposed a high lateral resolution common-path Fourier domain optical coherence tomography(OCT) system with the use of a chemically etched single mode fiber. In our experiments, single mode optical fiber for 1310nm was used for preparing the tapered tips. Our system used a conical microlens that was chemically etched by selective chemical etching technique using an etching solution of buffered hydrofluoric acid (BHF). From experimental results, we verified that our proposed optical coherence tomography system could operate as a common-path Fourier domain OCT system and conical tip lens fiber was very useful for a high lateral resolution common-path Fourier domain OCT system. Furthermore, we could observe a surface of paramecium bursaria and symbiotic chlorella in the paramecium bursaria using gold coated conical-tip fiber in the water.

  5. DO SLOVENIAN DEALERS USE TECHNIQUES FOR INCREASING THEIR TIPS?

    Directory of Open Access Journals (Sweden)

    Andrej Raspor

    2016-05-01

    Full Text Available In 1996 Michael Lynn introduced the idea that restaurant managers could increase tips for their waiters and thus increase turnover by training the waiters to engage tip-enhancing behaviours. Since then, the list of tip-enhancing behaviours has expanded. Therefore the potential to increase tips is more accessible. The purpose of this paper was to examine how Slovenian dealers use strategies to increase their tips. We tested fourteen techniques to increase tips. The study was carried out among 473 gaming employees, 279 of which are dealers, in the Slovenian gaming industry, in order to find out how they use these techniques and which of them can bring about an increase in their tips. The study showed that Slovenian dealers mostly do not use these techniques, and that the dealers who do use them tend to receive tips more often. The findings imply that managers and employees should be informed of these techniques in order to increase tips and their overall income. Practical implications are that we suggest that management considers these ideas for increasing flexibility and reducing the cost of work: (1 informing dealers on ways of increasing tips, (2 including the acquisition of this specific knowledge in their career plans, (3 carrying out a reform of the reward system which would include tips. Social implications will be shown in a higher gaming revenue. It is very likely – as shown in our research – that employees will receive higher wages as these will be topped up by tips. The state, in turn, will collect more taxes.

  6. Alar setback technique: a controlled method of nasal tip deprojection.

    Science.gov (United States)

    Foda, H M

    2001-11-01

    To describe an alar cartilage-modifying technique aimed at decreasing nasal tip projection in cases with overdeveloped alar cartilages and to compare it with other deprojection techniques used to correct such deformity. Selected case series. University and private practice settings in Alexandria, Egypt. Twenty patients presenting for rhinoplasty who had overprojected nasal tips primarily due to overdeveloped alar cartilages. All cases were primary cases except for one patient, who had undergone 2 previous rhinoplasties. An external rhinoplasty approach was used to set back the alar cartilages by shortening their medial and lateral crura. The choice of performing a high or low setback depended on the preexisting lobule-to-columella ratio. Following the setback, the alar cartilages were reconstructed in a fashion that increased the strength and stability of the tip complex. Subjective evaluation included clinical examination, analysis of preoperative and postoperative photographs, and patient satisfaction. Objective evaluation of nasal tip projection, using the Goode ratio and the nasofacial angle, was performed preoperatively and repeated at least 6 months postoperatively. A low setback was performed in 16 cases (80%) and a high setback in 4 (20%). The mean follow-up period was 18 months (range, 6-36 months). The technique effectively deprojected the nasal tip as evidenced by the considerable postoperative decrease in values of the Goode ratio and the nasofacial angle. No complications were encountered and no revision surgical procedures were required. The alar setback technique has many advantages; it results in precise predictable amounts of deprojection, controls the degree of tip rotation, preserves the natural contour of the nasal tip, respects the tip support mechanisms, increases the strength and stability of nasal tip complex, preserves or restores the normal lobule-to-columella proportion, and does not lead to alar flaring. However, the technique requires

  7. Oracle internals tips, tricks, and techniques for DBAs

    CERN Document Server

    Burleson, Donald K

    2001-01-01

    If you are a typical Oracle professional, you don't have the luxury of time to keep up with new technology and read all the new manuals to understand each new feature of the latest release from Oracle. You need a comprehensive source of information and in-depth tips and techniques for using the new technology. You need Oracle Internals: Tips, Tricks, and Techniques for DBAs.Oracle has evolved from a simple relational database into one of the most complex e-commerce platforms ever devised. It's not enough for you to understand just the Oracle database. You must also understand the components of

  8. Alveolar Ridge Split Technique Using Piezosurgery with Specially Designed Tips

    Directory of Open Access Journals (Sweden)

    Alessandro Moro

    2017-01-01

    Full Text Available The treatment of patients with atrophic ridge who need prosthetic rehabilitation is a common problem in oral and maxillofacial surgery. Among the various techniques introduced for the expansion of alveolar ridges with a horizontal bone deficit is the alveolar ridge split technique. The aim of this article is to give a description of some new tips that have been specifically designed for the treatment of atrophic ridges with transversal bone deficit. A two-step piezosurgical split technique is also described, based on specific osteotomies of the vestibular cortex and the use of a mandibular ramus graft as interpositional graft. A total of 15 patients were treated with the proposed new tips by our department. All the expanded areas were successful in providing an adequate width and height to insert implants according to the prosthetic plan and the proposed tips allowed obtaining the most from the alveolar ridge split technique and piezosurgery. These tips have made alveolar ridge split technique simple, safe, and effective for the treatment of horizontal and vertical bone defects. Furthermore the proposed piezosurgical split technique allows obtaining horizontal and vertical bone augmentation.

  9. Alveolar Ridge Split Technique Using Piezosurgery with Specially Designed Tips.

    Science.gov (United States)

    Moro, Alessandro; Gasparini, Giulio; Foresta, Enrico; Saponaro, Gianmarco; Falchi, Marco; Cardarelli, Lorenzo; De Angelis, Paolo; Forcione, Mario; Garagiola, Umberto; D'Amato, Giuseppe; Pelo, Sandro

    2017-01-01

    The treatment of patients with atrophic ridge who need prosthetic rehabilitation is a common problem in oral and maxillofacial surgery. Among the various techniques introduced for the expansion of alveolar ridges with a horizontal bone deficit is the alveolar ridge split technique. The aim of this article is to give a description of some new tips that have been specifically designed for the treatment of atrophic ridges with transversal bone deficit. A two-step piezosurgical split technique is also described, based on specific osteotomies of the vestibular cortex and the use of a mandibular ramus graft as interpositional graft. A total of 15 patients were treated with the proposed new tips by our department. All the expanded areas were successful in providing an adequate width and height to insert implants according to the prosthetic plan and the proposed tips allowed obtaining the most from the alveolar ridge split technique and piezosurgery. These tips have made alveolar ridge split technique simple, safe, and effective for the treatment of horizontal and vertical bone defects. Furthermore the proposed piezosurgical split technique allows obtaining horizontal and vertical bone augmentation.

  10. Crossed-swords, capsule-pinch technique for capsulotomy in pediatric and/or loose lens cataract extraction.

    Science.gov (United States)

    Snyder, Michael E; Lindsell, Luke B

    2010-02-01

    Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Electrostatic afocal-zoom lens design using computer optimization technique

    Energy Technology Data Exchange (ETDEWEB)

    Sise, Omer, E-mail: omersise@gmail.com

    2014-12-15

    Highlights: • We describe the detailed design of a five-element electrostatic afocal-zoom lens. • The simplex optimization is used to optimize lens voltages. • The method can be applied to multi-element electrostatic lenses. - Abstract: Electron optics is the key to the successful operation of electron collision experiments where well designed electrostatic lenses are needed to drive electron beam before and after the collision. In this work, the imaging properties and aberration analysis of an electrostatic afocal-zoom lens design were investigated using a computer optimization technique. We have found a whole new range of voltage combinations that has gone unnoticed until now. A full range of voltage ratios and spherical and chromatic aberration coefficients were systematically analyzed with a range of magnifications between 0.3 and 3.2. The grid-shadow evaluation was also employed to show the effect of spherical aberration. The technique is found to be useful for searching the optimal configuration in a multi-element lens system.

  12. A modified-simple technique of removing the lens cortex during cataract surgery

    Directory of Open Access Journals (Sweden)

    Kyung Eun Han

    2017-01-01

    Full Text Available We describe here a surgical technique of removing the remaining cortex after phacoemulsification without performing the conventional irrigation/aspiration (I/A procedure. In this technique, the remaining cortex attached to the posterior capsule was separated and dissected into several pieces by continuous irrigation with balanced salt solution, which was supplied through a syringe attached to a bent, blunt-tip needle. Approximately, 10 s of manual irrigation separated most of the remaining cortex from the posterior capsule. Then, the capsular bag was inflated with an ophthalmic viscoelastic device (OVD, and this pushed the separated cortex toward the capsular fornix mechanically. An intraocular lens was inserted into the capsular bag, following which the remaining cortex and OVD were removed concomitantly using an automated I/A handpiece. This technique is a simple and easy maneuver to remove the cortex from all areas, including the subincisional area, and reduce the possibility of a posterior capsule tear.

  13. Cytogenetic effects of 48titanium (48ti) on meristematic cells of root tips of lens culinaris med

    International Nuclear Information System (INIS)

    Sepet, H.; Bozdag, B.

    2014-01-01

    Cytogenetic effects of 48Titanium (48Ti) on meristematic cells of root tips belonging to the plant (Lens culinaris Medik.) have been Investigated. Seeds of the plant, prepared were kept in 48Ti standart for different time period as control during 1/4, 1/2, 1, 2, 4, 8, 12, 16, 20, 24 hours. Seeds treated with 48Ti were made sprout and the root tips obtained were prepared for microscopic examination. At the end of the microscopic examinations, some abnormalities as chromosome breakings, chromosome dispersion, bridge chromosome, chromosome adherence, ring chromosome were observed. Abnormalities were seen at each treatment depended on the time periods. Variety and number of abnormality were usually seen to be increasing, depending on the increase of treatment time. The results obtained were evaluated statistically. (author)

  14. Management of the droopy tip: a comparison of three alar cartilage-modifying techniques.

    Science.gov (United States)

    Foda, Hossam M T

    2003-10-01

    The droopy tip is a common nasal deformity in which the tip is inferiorly rotated. Five hundred consecutive rhinoplasty cases were studied to assess the incidence and causes of the droopy tip deformity and to evaluate the role of three alar cartilage-modifying techniques--lateral crural steal, lateral crural overlay, and tongue in groove--in correcting such a deformity. The external rhinoplasty approach was used in all cases. Only one of the three alar cartilage-modifying techniques was used in each case, and the degree of tip rotation and projection was measured both preoperatively and postoperatively. The incidence of droopy tip was 72 percent, and the use of an alar cartilage-modifying technique was required in 85 percent of these cases to achieve the desired degree of rotation. The main causes of droopy tip included inferiorly oriented alar cartilages (85 percent), overdeveloped scrolls of upper lateral cartilages (73 percent), high anterior septal angle (65 percent), and thick skin of the nasal lobule (56 percent). The lateral crural steal technique increased nasal tip rotation and projection, the lateral crural overlay technique increased tip rotation and decreased tip projection, and the tongue-in-groove technique increased tip rotation without significantly changing the amount of projection. The lateral crural overlay technique resulted in the highest degrees of rotation, followed by the lateral crural steal and finally the tongue-in-groove technique. According to these results, the lateral crural steal technique is best indicated in cases with droopy underprojected nasal tip, the lateral crural overlay technique in cases of droopy overprojected nasal tip, and the tongue-in-groove technique in cases where the droopy nasal tip is associated with an adequate amount of projection.

  15. Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique.

    Science.gov (United States)

    Yamane, Shin; Sato, Shimpei; Maruyama-Inoue, Maiko; Kadonosono, Kazuaki

    2017-08-01

    To report the clinical outcomes of a new technique for transconjunctival intrascleral fixation of an intraocular lens (IOL). Prospective, noncomparative, interventional case series. One hundred eyes of 97 consecutive patients with aphakia, dislocated IOL, or subluxated crystalline lens who underwent posterior chamber sutureless implantation of an IOL were studied. Two angled incisions parallel to the limbus were made by 30-gauge thin-wall needles. Haptics of an IOL were externalized with the needles and cauterized to make a flange of the haptics. The flange of the haptics were pushed back and fixed into the scleral tunnels. Best-corrected visual acuity (VA), corneal endothelial cell density, IOL tilt, and complications were determined. The IOLs were fixed with exact centration and axial stability. The mean preoperative best-corrected VA was 0.25 logarithm of the minimum angle of resolution (logMAR) units; after surgery, it improved significantly to 0.11 logMAR, 0.09 logMAR, 0.12 logMAR, and 0.04 logMAR at 6, 12, 24, and 36 months, respectively (P IOL tilt was 3.4°±2.5°. The postoperative complications included iris capture by the IOL in 8 eyes (8%), vitreous hemorrhage in 5 eyes (5%), and cystoid macular edema in 1 eye (1%). There were no incidents of postoperative retinal detachment, endophthalmitis, or IOL dislocation. We have developed a new technique for intrascleral IOL fixation. The flanged IOL fixation technique is a simple and minimally invasive method for achieving good IOL fixation with firm haptic fixation. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Rhinoplasty: a simplified, three-stitch, open tip suture technique. Part I: primary rhinoplasty.

    Science.gov (United States)

    Daniel, R K

    1999-04-01

    Tip suture techniques offer a reliable and dramatic method of tip modification without needing to interrupt the alar rim strip or add tip grafts. The present simplified three-stitch technique consists of the following: (1) a strut suture to fix the columella strut between the crura, (2) bilateral domal creation sutures to create tip definition, and (3) a domal equalization suture to narrow and align the domes. If required, columella septal sutures can be added; either a dorsal rotational suture or a transfixion projection suture can be used. This simplified method represents a refinement based on more than 13 years of experience with tip suture techniques. It does not require a complex operative sequence or specialized sutures. Primary indications are moderate tip deformities of inadequate definition and excessive width and certain specific tip deformities, including the parenthesis tip and nostril/tip disproportion. The primary contraindications are for patients with minor tip deformities that are best done through a closed approach and those with severe tip deformities requiring an open structure graft. The technique is simple, efficacious, and easily learned.

  17. Biological Small Angle Scattering: Techniques, Strategies and Tips

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhuri, Barnali [University at Buffalo (SUNY); Muñoz, Inés G. [Centro Nacional de Investigaciones Oncológicas Madrid, Madrid, Spain; Urban, Volker S. [ORNL; Qian, Shuo [ORNL

    2017-12-01

    This book provides a clear, comprehensible and up-to-date description of how Small Angle Scattering (SAS) can help structural biology researchers. SAS is an efficient technique that offers structural information on how biological macromolecules behave in solution. SAS provides distinct and complementary data for integrative structural biology approaches in combination with other widely used probes, such as X-ray crystallography, Nuclear magnetic resonance, Mass spectrometry and Cryo-electron Microscopy. The development of brilliant synchrotron small-angle X-ray scattering (SAXS) beam lines has increased the number of researchers interested in solution scattering. SAS is especially useful for studying conformational changes in proteins, highly flexible proteins, and intrinsically disordered proteins. Small-angle neutron scattering (SANS) with neutron contrast variation is ideally suited for studying multi-component assemblies as well as membrane proteins that are stabilized in surfactant micelles or vesicles. SAS is also used for studying dynamic processes of protein fibrillation in amyloid diseases, and pharmaceutical drug delivery. The combination with size-exclusion chromatography further increases the range of SAS applications.The book is written by leading experts in solution SAS methodologies. The principles and theoretical background of various SAS techniques are included, along with practical aspects that range from sample preparation to data presentation for publication. Topics covered include techniques for improving data quality and analysis, as well as different scientific applications of SAS. With abundant illustrations and practical tips, we hope the clear explanations of the principles and the reviews on the latest progresses will serve as a guide through all aspects of biological solution SAS.The scope of this book is particularly relevant for structural biology researchers who are new to SAS. Advanced users of the technique will find it helpful for

  18. New Technique for Fabrication of Scanning Single-Electron Transistor Microscopy Tips

    Science.gov (United States)

    Goodwin, Eric; Tessmer, Stuart

    Fabrication of glass tips for Scanning Single-Electron Transistor Microscopy (SSETM) can be expensive, time consuming, and inconsistent. Various techniques have been tried, with varying levels of success in regards to cost and reproducibility. The main requirement for SSETM tips is to have a sharp tip ending in a micron-scale flat face to allow for deposition of a quantum dot. Drawing inspiration from methods used to create tips from optical fibers for Near-Field Scanning Optical Microscopes, our group has come up with a quick and cost effective process for creating SSETM tips. By utilizing hydrofluoric acid to etch the tips and oleic acid to guide the etch profile, optical fiber tips with appropriate shaping can be rapidly prepared. Once etched, electric leads are thermally evaporated onto each side of the tip, while an aluminum quantum dot is evaporated onto the face. Preliminary results using various metals, oxide layers, and lead thicknesses have proven promising.

  19. Combined 30-degree bevel up and down technique against 0-degree phaco tip for phacoemulsification surgery of hard cataracts

    Directory of Open Access Journals (Sweden)

    Joshi RS

    2017-06-01

    Full Text Available Rajesh Subhash Joshi, Sonal Jayant Muley Department of Ophthalmology, Vasantrao Naik Government Medical College, Yavatmal, Maharashtra, India Purpose: To evaluate the effective phaco time (EPT, cumulative dissipated energy (CDE and nucleus emulsification time (NET as phaco parameters with 0- and 30-degree phaco tip. Patients and methods: This prospective, interventional and observational case series included 294 patients scheduled for cataract removal by phacoemulsification technique. Patients with nuclear cataracts of grade 4 and 5 nuclear opalescence of Lens Opacities Classification System III were included in the study. Patients were consecutively allocated to phaco chop technique with 0-degree (0-degree group, n=147 and combined bevel up and down position using 30-degree phaco tip (combined bevel up/down group, n=147. The 0-degree group had phacoemulsification with 0-degree phaco tip, while the 30-degree group had chopping of the nucleus with bevel down phaco tip and emulsification of nuclear fragments was accomplished with bevel up tip. EPT, CDE, NET and intraoperative complications were noted and compared between the groups using analysis of variance. Results: Average EPT, CDE and NET were lower in the 30-degree group than in the 0-degree group. However, no statistically significant difference was found in EPT (P=0.0733, CDE (P=0.0663 and NET (P=0.0633 between the two groups. No serious intraoperative complications were noted. The anterior chamber was maintained throughout the procedure in both groups. No patients had wound burn and miosis during the procedure. None of the patients developed bullous keratopathy, uveitis and cystoid macular edema during the follow-up period. Conclusion: Combined bevel up and down 30-degree tip can yield effective hard nucleus phacoemulsification. Bevel down tip of 30-degree helps in effective chopping and bevel up tip assists in emulsification of the nuclear fragments. Although combined bevel up and down 30

  20. [TIPS

    Science.gov (United States)

    Brazzini, Augusto; Carrillo, Alvaro; Cantella, Raúl

    1998-01-01

    Esophageal hemorrage due to variceal bleeding in cirrhotic patients represents a serious problem for the physician in charge, especially in this country where liver transplants are inexistent; and also, it is a drama for the patient and its familly. We propose here the Transjugular Intrahepatic Portosystemic Shunt (TIPS). Twenty one patients were part of a study where 23 TIPS were placed, observing an immediate improval in 18 of them, a rebleeding in 2, within the first 24 and 48 hours. An embolization of the coronary veins was performed in the procedure in 15 patients, and a second intervention due to rebleeding in 2 of them. In the latter patients, the embolization of the coronary veins was rutinary.The survival of the patients has been outstanding.We conclude that this interventional procedure is a worldwide reality in the treatment of esophageal hemorrage by variceal bleeding due to portal hipertension, and it does not cut down the probability of liver transplant, unfortunately inexistent in our country. This procedure results in a low morbimortality with an adequate quality of life.

  1. The lateral crural rein flap: a novel technique for management of tip rotation in primary rhinoplasty.

    Science.gov (United States)

    Kuran, Ismail; Öreroğlu, Ali Rıza; Efendioğlu, Kamran

    2014-09-01

    An important consideration in rhinoplasty is maintenance of the applied tip rotation. Different techniques have been proposed to accomplish this. Loss of rotation after surgery not only results in a derotated tip but also can create a supratip deformity. As a supplement to dorsal reconstruction, the authors introduced and applied the lateral crural rein flap technique, whereby cartilage flaps are created from the cephalic portion of the lateral crura to control and stabilize tip rotation. Eleven patients underwent primary open-approach rhinoplasty that included the lateral crural rein technique; the mean follow-up time was 18 months. Excess cephalic portions of the lateral crura were prepared as medial crura-based cartilaginous flaps and were incorporated into the nasal dorsum (similar to spreader grafts) and stabilized to achieve the desired tip rotation. The lateral crural rein flap technique provided stability to the nasal tip while minimizing derotation in the postoperative period. Long-term follow-up revealed maintenance of the nasal tip rotation and symmetric dorsal aesthetic lines. The lateral crural rein flap technique is effective for controlling nasal tip rotation while reducing lateral crural cephalic excess. Longevity of the applied tip rotation is reinforced by secure attachment of the lower nasal cartilage complex to the midvault structures. 4. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  2. Invited Review Article: Tip modification methods for tip-enhanced Raman spectroscopy (TERS) and colloidal probe technique: A 10 year update (2006-2016) review

    Science.gov (United States)

    Yuan, C. C.; Zhang, D.; Gan, Y.

    2017-03-01

    Engineering atomic force microscopy tips for reliable tip enhanced Raman spectroscopy (TERS) and colloidal probe technique are becoming routine practices in many labs. In this 10 year update review, various new tip modification methods developed over the past decade are briefly reviewed to help researchers select the appropriate method. The perspective is put in a large context to discuss the opportunities and challenges in this area, including novel combinations of seemingly different methods, potential applications of some methods which were not originally intended for TERS tip fabrication, and the problems of high cost and poor reproducibility of tip fabrication.

  3. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

    Directory of Open Access Journals (Sweden)

    Aditya Kelkar

    2015-07-01

    Full Text Available Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.

  4. Combined Scanning Nanoindentation and Tunneling Microscope Technique by Means of Semiconductive Diamond Berkovich Tip

    International Nuclear Information System (INIS)

    Lysenko, O; Novikov, N; Gontar, A; Grushko, V; Shcherbakov, A

    2007-01-01

    A combined Scanning Probe Microscope (SPM) - nanoindentation instrument enables submicron resolution indentation tests and in-situ scanning of structure surfaces. A newly developed technique is based on the scanning tunneling microscopy (STM) with integrated Berkovich diamond semiconductive tip. Diamond tips for a combined SPM were obtained using the developed procedure including the synthesis of the semiconductive borondoped diamond monocrystals by the temperature gradient method at high pressure - high temperature conditions and fabrication of the tips from these crystals considering their zonal structure. Separately grown semiconductive diamond single crystals were studied in order to find the best orientation of diamond crystals. Optimal scanning characteristics and experimental data errors were calculated by an analysis of the general functional dependence of the tunneling current from properties of the tip and specimen. Tests on the indentation and scanning of the gold film deposited on the silicon substrate employing the fabricated tips demonstrated their usability, acceptable resolution and sensitivity

  5. The ring cycle: an iterative lens reconstruction technique applied to MG1131 + 0456

    International Nuclear Information System (INIS)

    Kochanek, C.S.; Blandford, R.D.; Lawrence, C.R.; Narayan, R.

    1989-01-01

    A new technique is described for the analysis of well-resolved gravitational lens images. This method allows us to solve for the brightness distribution of the unlensed source as well as a parametrized model of the lens. Our algorithm computes a figure of merit for a lens model based on the scatter in the surface brightnesses of image elements that, according to the model, come from the same source element. Minimization of the figure of merit leads to an optimum solution for the source and the lens. We present a successful application of the method to VLA maps of the 'Einstein ring' radio source MG1131 + 0456 observed by previous authors. The inversion gives a normal galaxy-like elliptical potential for the lens and an ordinary double-lobed structure for the background radio source. (author)

  6. Techniques for blade tip clearance measurements with capacitive probes

    Science.gov (United States)

    Steiner, Alexander

    2000-07-01

    This article presents a proven but advantageous concept for blade tip clearance evaluation in turbomachinery. The system is based on heavy duty probes and a high frequency (HF) and amplifying electronic unit followed by a signal processing unit. Measurements are taken under high temperature and other severe conditions such as ionization. Every single blade can be observed. The signals are digitally filtered and linearized in real time. The electronic set-up is highly integrated. Miniaturized versions of the electronic units exist. The small and robust units can be used in turbo engines in flight. With several probes at different angles in one radial plane further information is available. Shaft eccentricity or blade oscillations can be calculated.

  7. Radiation therapy for retinoblastoma: comparison of results with lens-sparing versus lateral beam techniques

    International Nuclear Information System (INIS)

    McCormick, B.; Ellsworth, R.; Abramson, D.; Haik, B.; Tome, M.; Grabowski, E.; LoSasso, T.

    1988-01-01

    From 1979 through 1986, 170 children were seen at our institution diagnosed with retinoblastoma. Sixty-six of the children with involvement of 121 eyes, were referred for definitive external beam radiation to one or both eyes. During the study period, two distinct radiation techniques were used. From 1980 through mid-1984, a lens-sparing technique included an anterior electron beam with a contact lens mounted lead shield, combined with a lateral field, was used. Since mid-1984, a modified lateral beam technique has been used, mixing lateral electrons and superior and inferior lateral oblique split beam wedged photons. Doses prescribed were similar for both techniques, ranging from 3,850 to 5,000 cGy in 4 to 5 weeks. The lens-sparing and the modified lateral techniques are compared for local control. For eyes with Group I through III disease, the lens-sparing technique resulted in local control in 33% of the eyes treated, where the modified lateral technique controlled 83% of the eyes treated (p = .006). Mean time to relapse was identical in both groups, that is 24 and 26 months respectively. Most relapses were successfully treated with further local therapy, including laser or cryosurgery, or 60Co plaques. Five eyes required enucleation following initial treatment with the lens-sparing technique, but none thus far with the lateral beam technique. For eyes with Group IV and V disease, no significant differences were found between the two techniques in terms of local control or eventual need for enucleation. With a mean follow-up time of 33 months for the entire group, the 4-year survival is 93%. Two of the 4 deaths are due to second primary tumor, and all 4 have occurred in the lens-sparing group. Because follow-up time is more limited in the lateral beam group, this is not statistically significant and direct survival comparisons are premature

  8. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  9. Surgical Tips in Frozen Abdomen Management: Application of Coliseum Technique.

    Science.gov (United States)

    Kyriazanos, Ioannis D; Manatakis, Dimitrios K; Stamos, Nikolaos; Stoidis, Christos

    2015-01-01

    Wound dehiscence is a serious postoperative complication, with an incidence of 0.5-3% after primary closure of a laparotomy incision, and represents an acute mechanical failure of wound healing. Relatively recently the concept of "intentional open abdomen" was described and both clinical entities share common pathophysiological and clinical pathways ("postoperative open abdominal wall"). Although early reconstruction is the target, a significant proportion of patients will develop adhesions between abdominal viscera and the anterolateral abdominal wall, a condition widely recognized as "frozen abdomen," where delayed wound closure appears as the only realistic alternative. We report our experience with a patient who presented with frozen abdomen after wound dehiscence due to surgical site infection and application of the "Coliseum technique" for its definitive surgical management. This novel technique represents an innovative alternative to abdominal exploration, for cases of "malignant" frozen abdomen due to peritoneal carcinomatosis. Lifting the edges of the surgical wound upwards and suspending them under traction by threads from a retractor positioned above the abdomen facilitates approach to the peritoneal cavity, optimizes exposure of intra-abdominal organs, and prevents operative injury to the innervation and blood supply of abdominal wall musculature, a crucial step for subsequent hernia repair.

  10. Ergonomic factors related to drop-off detection with the long cane: effects of cane tips and techniques.

    Science.gov (United States)

    Kim, Dae Shik; Emerson, Robert S Wall; Curtis, Amy B

    2010-06-01

    This study examined the effect of cane tips and cane techniques on drop-off detection with the long cane. Blind pedestrians depend on a long cane to detect drop-offs. Missing a drop-off may result in falls or collision with moving vehicles in the street. Although cane tips appear to affect a cane user's ability to detect drop-offs, few experimental studies have examined such effect. A repeated-measures design with block randomization was used for the study. Participants were 17 adults who were legally blind and had no other disabilities. Participants attempted to detect the drop-offs of varied depths using different cane tips and cane techniques. Drop-off detection rates were similar between the marshmallow tip (77.0%) and the marshmallow roller tip (79.4%) when both tips were used with the constant contact technique, p = .294. However, participants detected drop-offs at a significantly higher percentage when they used the constant contact technique with the marshmallow roller tip (79.4%) than when they used the two-point touch technique with the marshmallow tip (63.2%), p marshmallow roller tip (perceived as a less advantageous tip) was more effective than the two-point touch technique used with a marshmallow tip (perceived as a more advantageous tip) in detecting drop-offs. The findings of the study may help cane users and orientation and mobility specialists select appropriate cane techniques and cane tips in accordance with the cane user's characteristics and the nature of the travel environment.

  11. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  12. Simple technique to treat pupillary capture after transscleral fixation of intraocular lens.

    Science.gov (United States)

    Jürgens, Ignasi; Rey, Amanda

    2015-01-01

    We describe a simple surgical technique to manage pupillary capture after previous transscleral fixation of an intraocular lens. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. A new technique for the closure of the lens capsule by laser welding.

    Science.gov (United States)

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  14. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  15. The Application of Globular Water-Atomized Iron Powders for Additive Manufacturing by a LENS Technique.

    Science.gov (United States)

    Durejko, Tomasz; Aniszewska, Justyna; Ziętala, Michał; Antolak-Dudka, Anna; Czujko, Tomasz; Varin, Robert A; Paserin, Vlad

    2018-05-18

    The water-atomized ATOMET 28, 1001, 4701, and 4801 powders, manufactured by Rio Tinto Metal Powders, were used for additive manufacturing by a laser engineered net shaping (LENS) technique. Their overall morphology was globular and rounded with a size distribution from about 20 to 200 µm. Only the ATOMET 28 powder was characterized by a strong inhomogeneity of particle size and irregular polyhedral shape of powder particles with sharp edges. The powders were pre-sieved to a size distribution from 40 to 150 µm before LENS processing. One particular sample-LENS-fabricated from the ATOMET 28 powder-was characterized by the largest cross-sectional (2D) porosity of 4.2% and bulk porosity of 3.9%, the latter determined by microtomography measurements. In contrast, the cross-sectional porosities of bulk, solid, nearly cubic LENS-fabricated samples from the other ATOMET powders exhibited very low porosities within the range 0.03⁻0.1%. Unexpectedly, the solid sample-LENS-fabricated from the reference, a purely spherical Fe 99.8 powder-exhibited a porosity of 1.1%, the second largest after that of the pre-sieved, nonspherical ATOMET 28 powder. Vibrations incorporated mechanically into the LENS powder feeding system substantially improved the flow rate vs. feeding rate dependence, making it completely linear with an excellent coefficient of fit, R² = 0.99. In comparison, the reference powder Fe 99.8 always exhibited a linear dependence of the powder flow rate vs. feeding rate, regardless of vibrations.

  16. Simple technique to evaluate the thermal lens strength of a laser material. SAIP 2005 Talk C-20

    CSIR Research Space (South Africa)

    Esser, D

    2005-01-01

    Full Text Available The presentation is about the simple technique to measure the thermal lens; Same pumping conditions as real laser; Same cooling configuration as real laser; Comparative experiment made; Nd:YVO4 has smaller thermal lens than Nd:GdVO4; Nd:GdVO4 has...

  17. A simple lens-sparing technique to treat hypotonic maculopathy secondary to large cyclodialysis

    OpenAIRE

    Masayo Kimura; Tsutomu Yasukawa; Yuichiro Ogura

    2018-01-01

    Purpose: Hypotonic maculopathy secondary to cyclodialysis often persists and causes irreversible visual loss despite a variety of treatments proposed. The purpose of this study is to report two cases with persistent hypotonic maculopathy due to a large cyclodialysis cleft treated with a simple, lens-sparing technique of external drainage, diathermy, and suturing under the placement of an infusion cannula. Observations: Both patients had sustained blunt trauma to one eye, causing persisting hy...

  18. Minimally Invasive Calcaneal Displacement Osteotomy Site Using a Reference Kirschner Wire: A Technique Tip.

    Science.gov (United States)

    Lee, Moses; Guyton, Gregory P; Zahoor, Talal; Schon, Lew C

    2016-01-01

    As a standard open approach, the lateral oblique incision has been widely used for calcaneal displacement osteotomy. However, just as with other orthopedic procedures that use an open approach, complications, including wound healing problems and neurovascular injury in the heel, have been reported. To help avoid these limitations, a percutaneous technique using a Shannon burr for calcaneal displacement osteotomy was introduced. However, relying on a free-hand technique without direct visualization at the osteotomy site has been a major obstacle for this technique. To address this problem, we developed a technical tip using a reference Kirschner wire. A reference Kirschner wire technique provides a reliable and accurate guide for minimally invasive calcaneal displacement osteotomy. Also, the technique should be easy to learn for surgeons new to the procedure. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Laser fiber cleaving techniques: effects on tip morphology and power output.

    Science.gov (United States)

    Vassantachart, Janna M; Lightfoot, Michelle; Yeo, Alexander; Maldonado, Jonathan; Li, Roger; Alsyouf, Muhannad; Martin, Jacob; Lee, Michael; Olgin, Gaudencio; Baldwin, D Duane

    2015-01-01

    Proper cleaving of reusable laser fibers is needed to maintain optimal functionality. This study quantifies the effect of different cleaving tools on power output of the holmium laser fiber and demonstrates morphologic changes using microscopy. The uncleaved tips of new 272 μm reusable laser fibers were used to obtain baseline power transmission values at 3 W (0.6 J, 5 Hz). Power output for each of four cleaving techniques-11-blade scalpel, scribe pen cleaving tool, diamond cleaving wheel, and suture scissors-was measured in a single-blinded fashion. Dispersion of light from the fibers was compared with manufacturer specifications and rated as "ideal," "acceptable," or "unacceptable" by blinded reviewers. The fiber tips were also imaged using confocal and scanning electron microscopy. Independent samples Kruskal-Wallis test and chi square were used for statistical analysis (αtrend that was highly significant (Ptrend as the power output results (P<0.001). Microscopy showed that the scribe pen produced small defects along the fiber cladding but maintained a smooth, flat core surface. The other cleaving techniques produced defects on both the core and cladding. Cleaving techniques produce a significant effect on the initial power transmitted by reusable laser fibers. The scribe pen cleaving tool produced the most consistent and highest average power output.

  20. Two-step technique for posterior optic buttonholing of intraocular lens.

    Science.gov (United States)

    Agarwal, Tushar; Jhanji, Vishal; Singh, Digvijay; Khokhar, Sudarshan

    2014-04-01

    This study aims to describe a two-step surgical technique for placement of a posterior chamber intraocular lens (IOL) in cases with crystalline lens subluxation resulting from non-progressive zonular dialysis. The first stage entails a phacoemulsification with creation of a 4-mm posterior capsular opening using an automated vitrector. The second stage performed 6 weeks later includes an anterior vitrectomy and injection of a foldable three-piece IOL in the sulcus. The haptics of IOL are positioned in the sulcus while the optic is pushed behind the posterior capsular opening therefore "buttonholing" the IOL. Seven eyes of seven patients with posttraumatic zonular dialysis were operated using this technique. Follow-up of all cases revealed a well-centered IOL with good postoperative visual acuity (20/20 to 20/80). Our two-stage surgical technique precludes the insertion of capsular tension ring in cases with non-progressive zonular dialysis. The technique is recommended in the presence of less than or equal to 6 clock hours of zonular dialysis with preexisting posterior capsular tear or herniation of vitreous in the anterior chamber.

  1. Net technique for intraocular lens support in aphakia without capsular support.

    Science.gov (United States)

    De Novelli, Fernando José; Neto, Theodomiro Lourenço Garrido; de Sena Rabelo, Gabriel; Blumer, Marcel Eduardo; Suzuki, Ricardo; Ghanem, Ramon Coral

    2017-01-01

    This paper describes a modified surgical technique for intraocular lens implantation in aphakic eyes with no capsular support. Retrospective case series. Seventeen eyes of 17 aphakic patients with no capsule support underwent intraocular lens (IOL) implantation using a standardized technique in which a net was created at the ciliary sulcus plane with two threads forming a net pattern. The net was used as support for the IOL. Follow-up ranged from 6 to 38 months, with an average of 23 months. In all cases, the IOL was safely implanted and remained stable during the follow-up. In 16 eyes, the IOL remained well centered; in one eye, slight decentration was observed. Distance-corrected visual acuity improved by a mean of 4 lines, from 1.13 (LogMAR) to 0.52 (P = 0.01). This technique might be especially useful in cases of insufficient capsular support associated with tissue loss or iris atrophy. In these cases, iris fixation is not feasible; thus, the only surgical alternative is IOL scleral fixation.

  2. Lens sparing technique using multi-leaf collimators in irradiation of the unilateral retro-orbital space for benign disease

    International Nuclear Information System (INIS)

    Middleton, Mark; Medwell, Stephen; Bennie, David; Fogarty, Gerald

    2005-01-01

    The authors present a case of a 30-year-old woman with pseudolymphoma of the left medial rectus muscle. A multi-field technique was planned for irradiating the unilateral retro-orbital space to 20 Gray (GY) in 15 fractions while keeping the average dose to the lens of 8 Gy and the peak dose to the lens of 11 Gy using multi-leaf collimators is described. Copyright (2005) Australian Institute of Radiography

  3. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  4. Oracle database 12c release 2 in-memory tips and techniques for maximum performance

    CERN Document Server

    Banerjee, Joyjeet

    2017-01-01

    This Oracle Press guide shows, step-by-step, how to optimize database performance and cut transaction processing time using Oracle Database 12c Release 2 In-Memory. Oracle Database 12c Release 2 In-Memory: Tips and Techniques for Maximum Performance features hands-on instructions, best practices, and expert tips from an Oracle enterprise architect. You will learn how to deploy the software, use In-Memory Advisor, build queries, and interoperate with Oracle RAC and Multitenant. A complete chapter of case studies illustrates real-world applications. • Configure Oracle Database 12c and construct In-Memory enabled databases • Edit and control In-Memory options from the graphical interface • Implement In-Memory with Oracle Real Application Clusters • Use the In-Memory Advisor to determine what objects to keep In-Memory • Optimize In-Memory queries using groups, expressions, and aggregations • Maximize performance using Oracle Exadata Database Machine and In-Memory option • Use Swingbench to create d...

  5. High-Quality Large-Magnification Polymer Lens from Needle Moving Technique and Thermal Assisted Moldless Fabrication Process.

    Directory of Open Access Journals (Sweden)

    Ratthasart Amarit

    Full Text Available The need of mobile microscope is escalating as well as the demand of high quality optical components in low price. We report here a novel needle moving technique to fabricate milli-size lens together with thermal assist moldless method. Our proposed protocol is able to create a high tensile strength structure of the lens and its base which is beneficial for exploiting in convertinga smart phone to be a digital microscope. We observe that no bubble trapped in a lens when this technique is performed which can overcome a challenge problem found in a typical dropping technique. We demonstrate the symmetry, smoothness and micron-scale resolution of the fabricated structure. This proposed technique is promising to serve as high quality control mass production without any expensive equipment required.

  6. Assessment of phacoaspiration techniques in clear lens extraction for correction of high myopia

    Directory of Open Access Journals (Sweden)

    Mostafa A El-Helw

    2010-03-01

    Full Text Available Mostafa A El-Helw, Ahmed M EmarahDepartment of Ophthalmology, Cairo University, EgyptPurpose: To evaluate various phacoaspiration techniques in clear lens extraction for the incidence of intraoperative difficulties and complications.Patients and methods: This was a prospective study in which bilateral clear lens extraction was performed on 40 eyes of 20 patients, to correct high myopia. The patients were divided into 2 groups: group A underwent supracapsular phacoaspiration; group B were the contralateral eyes of the same patient. These patients were operated on with endocapsular phacoaspiration with the divide and conquer (D and C technique. Preoperative ocular examination data were recorded and tested for significance. Intraoperative difficulties and complications such as nucleus cracking, capsule rupture and vitreous loss, and repeated chamber collapse were recorded. Postoperative examination data were recorded.Results: Mean age was 35.65 ± 5.85 years. Mean follow-up time was 17.1 ± 8.56 months. In group A mean myopia was -17.3 ± 5.07 diopters; in group B myopia was -17.9 ± 4.20 diopters. Mean preoperative uncorrected visual acuity (UCVA was 0.04 ± 0.0167, while the mean postoperative UCVA was 0.435 ± 0.1442. There was a significant difference in pre and postoperative BCVA within both groups, but not between the two groups. In both groups endothelial cell count (ECC showed a significant difference between pre- and postoperative data; however, there was no statistically significant difference between both groups in postoperative ECC. The effective phacoaspiration time for group A was 4.6 ± 1.6 seconds, and for group B 9.90 ± 2.27 seconds (P < 0.005. No cases of capsule rupture occurred in group A, but 3 cases occurred in group B (15 % (not significant, P = 0.231. Nucleus cracking did not occur in group A, but in group B 13 cases occurred (65%. Chamber collapse occurred in 4 cases (20% in group A and 5 cases (25% in group B (not

  7. Cavity Ring Down and Thermal Lens Techniques Applied to Vibrational Spectroscopy of Gases and Liquids

    Science.gov (United States)

    Nyaupane, Parashu Ram

    Infrared (IR) and near-infrared (NIR) region gas temperature sensors have been used in the past because of its non-intrusive character and fast time response. In this dissertation cavity ring down (CRD) absorption of oxygen around the region 760 nm has been used to measure the temperature of flowing air in an open optical cavity. This sensor could be a convenient method for measuring the temperature at the input (cold air) and output (hot air) after cooling the blades of a gas turbine. The results could contribute to improvements in turbine blade cooling designs. Additionally, it could be helpful for high temperature measurement in harsh conditions like flames, boilers, and industrial pyrolysis ovens as well as remote sensing. We are interested in experiments that simulate the liquid methane and ethane lakes on Titan which is around the temperature of 94 K. Our specific goal is to quantify the solubility of unsaturated hydrocarbons in liquid ethane and methane. However, it is rather complicated to do so because of the low temperatures, low solubility and solvent effects. So, it is wise to do the experiments at higher temperature and test the suitability of the techniques. In these projects, we were trying to explore if our existing laboratory techniques were sensitive enough to obtain the solubility of unsaturated hydrocarbons in liquid ethane. First, we studied the thermal lens spectroscopy (TLS) of the (Deltav = 6) C-H overtone of benzene and naphthalene in hexane and CCl4 at room temperature.

  8. Evaluation of different surgical techniques in the management of subluxated cataractous lens.

    Science.gov (United States)

    Aldakaf, A; Bakir, H; Almogahed, A; Carstocea, Benone

    2007-01-01

    To compare and evaluate the outcome of different surgical techniques in the management of subluxated cataractous lens. This retrospective study included 18 eyes of 18 patients with subluxated cataracts of varying etiology. Their preoperative examination maintain included: best corrected visual acuity (BCVA), thorough anterior segment examination, by slit -lamp especially for the degree and extent of subluxation and cataract, cornea, iris and the pupil for other abnormalities or other traumatic signs, presence or absence of vitreous in the anterior chamber, IOP and finally fundus examination. The patients were then divided into 3 groups each comprising 6 patients. The first group underwent ECCE with sulcus implantation PMMA IOL , the second and third groups underwent phacoemulsification with bag implanted Acrylic IOL but the third group underwent special techniques and precautions during surgery. Postoperatively, all patients were examined for BCVA, IOP, IOL positioning, pupil, fundus examination. Thirteen patients were males and five were females. The etiology of subluxation was traumatic in ten males and two female. The ages of the patients were between 11 and 62 years old the post operative follow up period ranged between 7 and 16 months. No major intraoperative complications were noted. In the 1st group 2 patients underwent AC automated vitrectomy, 3 in the 2nd group, 1 in the 3rd group. Three patients needed scleral fixation suture . Thirteen patients had well centered IOL and 4 had slight decentration not necessitating further intervention and one in the 2nd group had clinically significant decentration where IOL explanation, widening of the wound and re implantation of a wide 6.5mm optic PMMA IOL was done in the second post operative daily. Subluxated cataracts need special precautions in the chosen surgical technique to maintain a reasonable safety level intraoperatively and an acceptable surgical.

  9. The development of fabrication techniques for europia/iron cermet tips for coarse-control arms in DIDO and PLUTO

    International Nuclear Information System (INIS)

    Moore, D.A.; Tarrant, E.A.

    1980-11-01

    The applicability of cermet-fabrication techniques to the production of europia/iron cermets for use as coarse-control arm tips in the materials test reactors DIDO and PLUTO has been investigated. Spheroids of europia were prepared by a dry agglomeration process. These were sintered, dispersed in iron powder and pressed into plates; the plates were then sintered to densify the iron matrix. These stages were optimised to produce a strong cermet with a europia density of >= 2.75 g/cm 3 . The uniformity of distribution of the absorber particles was confirmed by radiography, and adequate neutron-absorption worth by measurements carried out in the GLEEP reactor. An outline flow sheet has been prepared for the manufacture of europia/iron cermet plates suitable for use in the tips of DIDO and PLUTO coarse-control arms. (author)

  10. Study of the capacitance technique for measuring high-temperature blade tip clearance on ceramic rotors

    Science.gov (United States)

    Barranger, John P.

    1993-01-01

    Higher operating temperatures required for increased engine efficiency can be achieved by using ceramic materials for engine components. Ceramic turbine rotors are subject to the same limitations with regard to gas path efficiency as their superalloy predecessors. In this study, a modified frequency-modulation system is proposed for the measurement of blade tip clearance on ceramic rotors. It is expected to operate up to 1370 C (2500 F), the working temperature of present engines with ceramic turbine rotors. The design of the system addresses two special problems associated with nonmetallic blades: the capacitance is less than that of a metal blade and the effects of temperature may introduce uncertainty with regard to the blade tip material composition. To increase capacitance and stabilize the measurement, a small portion of the rotor is modified by the application of 5-micron-thick platinum films. The platinum surfaces on the probe electrodes and rotor that are exposed to the high-velocity gas stream are coated with an additional 10-micron-thick protective ceramic topcoat. A finite-element method is applied to calculate the capacitance as a function of clearance.

  11. Modeling of radial asymmetry in lens distortion facilitated by modern optimization techniques

    CSIR Research Space (South Africa)

    De Villiers, Johan P

    2010-01-18

    Full Text Available when applied to low order models. A new tool has been created which can provide extremely accurate distortion characterization. This allows high-end photogrammetric applications to improve their accuracy even if they already use complex models... distortion with a closed form solution and inverse function, Master’s thesis ], University of Pretoria, Pretoria, RSA (2008). [4] Conrady, A., \\Decentered lens systems," Monthly Notices of the Royal Astronomical Society 79, 384{390 (1919). [5] Brown, D...

  12. Combined surgical management of capsular and iris deficiency with glued intraocular lens technique.

    Science.gov (United States)

    Kumar, Dhivya Ashok; Agarwal, Amar; Jacob, Soosan; Lamba, Mandeep; Packialakshmi, Sathiya; Meduri, Alessandro

    2013-05-01

    To determine the outcome after glued aniridia intraocular lens (IOL) and glued IOL with iridoplasty in eyes with combined lens capsular and iris deficiency. Twenty-seven eyes of 25 patients (6 had congenital aniridia with subluxated cataract and 19 had acquired lens/iris defects) were included. Glued IOL with aniridia IOL (Intra Ocular Care, Gujarat, India) was performed in eyes with total aniridia and iridoplasty with glued IOL with a three-piece foldable IOL (Sofport; Bausch & Lomb, Rochester, NY) was performed in eyes with partial aniridia. The postoperative outcomes were analyzed at follow-up examination (range: 6 to 48 months). Eleven eyes underwent glued aniridia IOL and 16 eyes underwent glued IOL with iridoplasty. There was significant improvement in (spectacle) corrected distance visual acuity (CDVA) (P = .002). Postoperatively, pigment dispersion on the IOL (n = 1) and raised intraocular pressure was seen in the glued aniridia IOL group and chronic uveitis (n = 1), cystoid macular edema (n = 1), and hyphema (n = 1) in the glued IOL with iridoplasty group. The CDVA remained unchanged in 14 eyes (51.8%) and improved in 13 eyes (48.1%). There was a difference in postoperative CDVA (P = .001) between eyes with glued aniridia IOL and glued IOL with iridoplasty. There was no IOL decentration, retinal detachment, corneal decompensation, or endophthalmitis. There was reduction in glare and photophobia. Both glued aniridia IOL and glued IOL/iridoplasty showed good functional and anatomical results with fewer complications in eyes with lens capsule and iris deficiency. However, long-term follow-up is required.[J Refract Surg. 2013;29(5):342-347.]. Copyright 2013, SLACK Incorporated.

  13. Comparison of Visual Data Collection Techniques on Mizar: The Barlow Lens

    Science.gov (United States)

    Bensel, Holly; Peard, Nolan; Peccia, Dashton; Scimeca, David

    2013-01-01

    Since turning their eyes to the heavens and gazing at the celestial bodies therein, mankind has been restricted and limited in his knowledge of the cosmos by the resolving power of first, the naked-eye, and later, the telescope. It has been the goal of astronomers worldwide to create larger and more powerful telescopes with higher resolving capabilities. Such large telescopes are not an option, however, for amateur astronomers and as such they must rely on other instruments and tools to achieve greater precision. One of these tools is the Barlow lens, used to increase the magnification power of a telescope by increasing its focal length. This magnification can assist in precision and accuracy of observations, especially when measuring the angular separation. Continuing their previous work in double star research (Bensel, Peard, Peccia, Scimeca, et al.), a contingent from St. Mary's School in Medford, Oregon compared the usage of a 2X Barlow lens with their usual telescope configuration and discuss the advantages and disadvantages they experienced with each.

  14. The global percutaneous shuttling technique tip for arthroscopic rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Bryan G. Vopat

    2014-05-01

    Full Text Available Most arthroscopic rotator cuff repairs utilize suture passing devices placed through arthro- scopic cannulas. These devices are limited by the size of the passing device where the suture is passed through the tendon. An alternative technique has been used in the senior author’s practice for the past ten years, where sutures are placed through the rotator cuff tendon using percutaneous passing devices. This technique, dubbed the global percutaneous shuttling technique of rotator cuff repair, affords the placement of sutures from nearly any angle and location in the shoulder, and has the potential advantage of larger suture bites through the tendon edge. These advantages may increase the area of tendon available to compress to the rotator cuff footprint and improve tendon healing and outcomes. The aim of this study is to describe the global percutaneous shuttling (GPS technique and report our results using this method. The GPS technique can be used for any full thickness rotator cuff tear and is particularly useful for massive cuff tears with poor tissue quality. We recently followed up 22 patients with an average follow up of 32 months to validate its usefulness. American Shoulder and Elbow Surgeons scores improved significantly from 37 preoperatively to 90 postoperatively (P<0.0001. This data supports the use of the GPS technique for arthroscopic rotator cuff repair. Further biomechanical studies are currently being performed to assess the improvements in tendon footprint area with this technique.

  15. JETSTREAM Atherectomy: A Review of Technique, Tips, and Tricks in Treating the Femoropopliteal Lesions

    Science.gov (United States)

    Shammas, Nicolas W.

    2014-01-01

    JETSTREAM (Bayer, Whippany, NJ) atherectomy is a highly effective rotational atherectomy device with active aspiration capacity approved in the United States to treat infrainguinal obstructive peripheral arterial disease. The technique in using the JETSTREAM is critical and relies on appropriate wire use, appropriate sizing, and speed in advancing the cutter as well as the use of fluoroscopic imaging and tactile and auditory senses. Using the right technique, the device appears to have a low rate of distal embolization and complications and results in high procedural success. We describe our own experience with the JETSTREAM device and the techniques used in our endovascular laboratory. PMID:26060377

  16. Technique tip: Simultaneous first metatarsal lengthening and metatarsophalangeal joint fusion for failed hallux valgus surgery with transfer metatarsalgia.

    Science.gov (United States)

    Chowdhary, Ashwin; Drittenbass, Lisca; Stern, Richard; Assal, Mathieu

    2017-03-01

    Failed hallux valgus surgery may result in residual or recurrent hallux valgus, and as well transfer metatarsalgia. The present technical tip concerns the combination of fusion of the first metatarsophalangeal (MTP) joint and lengthening of the first metatarsal (MT) through a scarf osteotomy. Six patients underwent the presented technique, all for the indication of failed hallux valgus surgery with shortening of the first MT and degenerative changes in the 1st MTP joint. Follow-up at six months revealed all patients had complete healing of the osteotomy and arthrodesis sites. They were all asymptomatic and fully active, completely satisfied with the outcome. Combined fusion of the first MTP joint and lengthening of the first MT through a scarf osteotomy results in an excellent outcome in patients with failed hallux valgus surgery with shortening of the first MT and degenerative changes in the 1st MTP joint. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  17. Anatomic deltoid ligament repair with anchor-to-post suture reinforcement: technique tip.

    Science.gov (United States)

    Lack, William; Phisitkul, Phinit; Femino, John E

    2012-01-01

    The deltoid ligament is the primary ligamentous stabilizer of the ankle joint. Both superficial and deep components of the ligament can be disrupted with a rotational ankle fracture, chronic ankle instability, or in late stage adult acquired flatfoot deformity. The role of deltoid ligament repair in these conditions has been limited and its contribution to arthritis is largely unknown. Neglect of the deltoid ligament in the treatment of ankle injuries may be due to difficulties in diagnosis and lack of an effective method for repair. Most acute repair techniques address the superficial deltoid ligament with direct end-to-end repair, fixation through bone tunnels, or suture anchor repair of avulsion injuries. Deep deltoid ligament repair has been described using direct end-to-end repair with sutures, as well as by autograft and allograft tendon reconstruction utilizing various techniques. Newer tenodesis techniques have been described for late reconstruction of both deep and superficial components in patients with stage 4 adult acquired flatfoot deformity. We describe a technique that provides anatomic ligament-to-bone repair of the superficial and deep bundles of the deltoid ligament while reducing the talus toward the medial malleolar facet of the tibiotalar joint with anchor-to-post reinforcement of the ligamentous repair. This technique may protect and allow the horizontally oriented fibers of the deep deltoid ligament to heal with the appropriate resting length while providing immediate stability of the construct.

  18. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    International Nuclear Information System (INIS)

    Sahin, Guelden; Demirtas, Mehmet

    2006-01-01

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established

  19. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Guelden [Department of Radiology, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)]. E-mail: gsahin@medicine.ankara.edu.tr; Demirtas, Mehmet [Department of Hand Surgery, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)

    2006-06-15

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established.

  20. Reconstruction of Long Bone Infections Using the Induced Membrane Technique: Tips and Tricks.

    Science.gov (United States)

    Mauffrey, Cyril; Hake, Mark E; Chadayammuri, Vivek; Masquelet, Alain-Charles

    2016-06-01

    The management of posttraumatic long bone osteomyelitis remains a challenging clinical problem. A systematic approach is necessary, beginning with eradication of the infected bone and soft tissue. There are a number of options for reconstruction of the remaining bone defect, including the induced membrane technique developed by Masquelet. We describe our technique for the 2-stage treatment of long bone osteomyelitis. The first stage involves a radical debridement, stabilization of the bone with either external fixation or an antibiotic-coated intramedullary nail, and placement of a polymethylmethacrylate spacer. The second stage includes excision of the spacer and placement of autologous bone graft. Various resection methods, fixation strategies, antibiotic additives, and types of bone grafts or substitutes can be used. The purpose of our technical article is to share our personal experience and describe several nuances that are critical for the success of this treatment strategy. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  1. Minimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip

    Directory of Open Access Journals (Sweden)

    Tyler A. Gonzalez

    2017-01-01

    Full Text Available Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to describe in detail the minimally invasive surgical approach for distal fibula fractures.

  2. Tips for TIPS

    NARCIS (Netherlands)

    Cuijpers, C.F.

    2015-01-01

    The transjugular intrahepatic portosystemic shunt (TIPS) procedure is one of the most technically challenging procedures in interventional radiology. During the procedure, interventional radiologists (IRs) insert very thin and long instruments through a little incision in the patient’s neck. They

  3. Supracapsular glued intraocular lens in progressive subluxated cataracts: Technique to retain an intact vitreous face.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Mazzotta, Cosimo; Rechichi, Miguel; Agarwal, Athiya

    2017-03-01

    We describe a technique to prevent late intraocular lens (IOL) subluxation and dislocation that can be associated with progressive zonulopathy. Supracapsular glued IOL fixation is done to retain an intact anterior hyaloid face and avoid vitreous disturbance while providing stable long-term IOL fixation. Phacoemulsification is followed by glued IOL implantation above intact anterior and posterior capsules. Sclerotomies are created ab interno in a supracapsular plane under diametrically opposite lamellar scleral flaps without entering the vitreous cavity. Haptics are externalized in the supracapsular plane and tucked into intrascleral tunnels. Intraoperative or postoperative posterior capsulorhexis or capsulotomy and anterior capsule relaxing cuts can prevent capsule phimosis. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. 100 ways to make good photos great tips & techniques for improving your digital photography

    CERN Document Server

    Cope, Peter

    2013-01-01

    A practical, accessible guide to turning your good photographs into great ones whether you are shooting on the latest digital SLR or a camera phone! Discover 100 simple and fun ways to improve your photographs both in-camera and through post-processing image manipulation. Every key photographic genre is covered, from perfect portraits and the great outdoors, to travel photos and shooting at night. Filled with inspirational examples of great photographs compared against the more average images, with easy to follow techniques for how you can achieve the same results.

  5. Wood lens design philosophy based on a binary additive manufacturing technique

    Science.gov (United States)

    Marasco, Peter L.; Bailey, Christopher

    2016-04-01

    Using additive manufacturing techniques in optical engineering to construct a gradient index (GRIN) optic may overcome a number of limitations of GRIN technology. Such techniques are maturing quickly, yielding additional design degrees of freedom for the engineer. How best to employ these degrees of freedom is not completely clear at this time. This paper describes a preliminary design philosophy, including assumptions, pertaining to a particular printing technique for GRIN optics. It includes an analysis based on simulation and initial component measurement.

  6. Para-axillary subcutaneous endoscopic approach in torticollis: tips and tricks in the surgical technique.

    Science.gov (United States)

    Tokar, Baran; Karacay, Safak; Arda, Surhan; Alici, Umut

    2015-04-01

    An obvious scar on the neck may appear following the open surgery for congenital muscular torticollis (CMT). The cosmetic result may displease the patient and the family. In this study, we describe a minimally invasive technique, para-axillary subcutaneous endoscopic approach (PASEA) in CMT. A total of 11 children (seven girls and four boys with the age range between 1 and 15 years) were operated for torticollis by PASEA. All patients had facial asymmetry and head and neck postural abnormality. Following an incision at the ipsilateral para-axillary region, a subcutaneous cavernous working space is formed toward sternocleidomastoid (SCM) muscle. The muscle and fascia are cut by cautery under endoscopic vision. The patients had postoperative 2nd-week and 3rd-month visits. The incision scar, inspection, and palpation findings of the region, head posture, and shoulder position of the affected side were considered in evaluation of the cosmetic outcome. Preoperative and postoperative range of motion of the head and neck were compared for functional outcome. We preferred single incision surgery in our last two patients; the rest had double para-axillary incision for port insertion. Incomplete transection of the muscle was not observed. There was no serious complication. Postoperatively, head posture and shoulder elevation were corrected significantly. Range of motion of the head was improved. Postoperatively, all the patients had rotation capacity with more than 30 degrees. The range of postoperative flexion and extension movements was between 45 and 60 degrees. The open surgery techniques of CMT causes visible lifelong incision scar on the neck. PASEA leaves a cosmetically hidden scar in the axillary region. A single incision surgery is also possible. A well-formed cavernous working space is needed. External manual palpation, delicate dissection, and cutting of SCM muscle with cautery are the important components of the procedure. Surgeons having experience in pediatric

  7. Tipping Point

    Medline Plus

    Full Text Available ... death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ... tv tip-overs. The force of a large television falling from tipping furniture can be staggering. A ...

  8. CPAP Tips

    Science.gov (United States)

    ... now Try it free Find out why Close CPAP Tips from FDA USFoodandDrugAdmin Loading... Unsubscribe from USFoodandDrugAdmin? ... apnea and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from ...

  9. Tipping Point

    Medline Plus

    Full Text Available ... and furniture, appliance and tv tip-overs. The force of a large television falling from tipping furniture ... 50 lb. TV falls with about the same force as child falling from the third story of ...

  10. Tipping Point

    Medline Plus

    Full Text Available ... Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture ... about horrible accidents involving young children and furniture, appliance and tv tip-overs. The force of a ...

  11. Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-associated Refractory Hepatic Encephalopathy by Shunt Reduction Using the Parallel Technique: Outcomes of a Retrospective Case Series

    International Nuclear Information System (INIS)

    Cookson, Daniel T.; Zaman, Zubayr; Gordon-Smith, James; Ireland, Hamish M.; Hayes, Peter C.

    2011-01-01

    Purpose: To investigate the reproducibility and technical and clinical success of the parallel technique of transjugular intrahepatic portosystemic shunt (TIPS) reduction in the management of refractory hepatic encephalopathy (HE). Materials and Methods: A 10-mm-diameter self-expanding stent graft and a 5–6-mm-diameter balloon-expandable stent were placed in parallel inside the existing TIPS in 8 patients via a dual unilateral transjugular approach. Changes in portosystemic pressure gradient and HE grade were used as primary end points. Results: TIPS reduction was technically successful in all patients. Mean ± standard deviation portosystemic pressure gradient before and after shunt reduction was 4.9 ± 3.6 mmHg (range, 0–12 mmHg) and 10.5 ± 3.9 mmHg (range, 6–18 mmHg). Duration of follow-up was 137 ± 117.8 days (range, 18–326 days). Clinical improvement of HE occurred in 5 patients (62.5%) with resolution of HE in 4 patients (50%). Single episodes of recurrent gastrointestinal hemorrhage occurred in 3 patients (37.5%). These were self-limiting in 2 cases and successfully managed in 1 case by correction of coagulopathy and blood transfusion. Two of these patients (25%) died, one each of renal failure and hepatorenal failure. Conclusion: The parallel technique of TIPS reduction is reproducible and has a high technical success rate. A dual unilateral transjugular approach is advantageous when performing this procedure. The parallel technique allows repeat bidirectional TIPS adjustment and may be of significant clinical benefit in the management of refractory HE.

  12. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    Science.gov (United States)

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  13. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  14. Luneburg lens in silicon photonics.

    Science.gov (United States)

    Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf

    2011-03-14

    The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms.

  15. Atomic force microscopy and Langmuir–Blodgett monolayer technique to assess contact lens deposits and human meibum extracts

    Directory of Open Access Journals (Sweden)

    Sarah Hagedorn

    2015-07-01

    Conclusions: MGD and non-MGD participant-worn CL deposition were found to differ in type, amount, and pattern of lens deposits. Lipids from MGD participants deposited irregularly whereas lipids from non-MGD participants showed more uniformity.

  16. CPAP Tips

    Medline Plus

    Full Text Available ... now Try it free Find out why Close CPAP Tips from FDA USFoodandDrugAdmin Loading... Unsubscribe from USFoodandDrugAdmin? ... apnea and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from ...

  17. Technology Tips

    Science.gov (United States)

    Mathematics Teacher, 2004

    2004-01-01

    Some inexpensive or free ways that enable to capture and use images in work are mentioned. The first tip demonstrates the methods of using some of the built-in capabilities of the Macintosh and Windows-based PC operating systems, and the second tip describes methods to capture and create images using SnagIt.

  18. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  19. Tipping Point

    Medline Plus

    Full Text Available ... 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ...

  20. Characterization of metal-coated fiber tip for NSOM lithography by tip-to-tip scan

    International Nuclear Information System (INIS)

    Kubicova, I.; Pudis, D.; Suslik, L.; Skriniarova, J.

    2011-01-01

    For the optical field characterization, a tip-to-tip scan of two metal-coated fiber tips with circular aperture at the apex was performed. The optical field irradiated from the fiber probe in illumination mode was analyzed by NSOM represented by fiber probe in collection mode. The near-field intensity profile of the source fiber tip in the plane perpendicular to the axis of the tip was taken. Experimental stage requires high resolution 3D motion system controlled by computer (Fig. 1). The source and the detector fiber tip were placed on the moving and static part of the 3D nanoposition system, respectively. As a light source, a modulated 473 nm DPSS laser was used. After the source fiber tip characterization, the NSOM lithography was performed. In the experimental setup from Fig. 1, the detector fiber tip was replaced by a sample fixed in a vacuum holder. As a sample, a 600 nm positive photoresist AZ 5214E was spin-coated on a GaAs substrate. Exposure was carried out by irradiation of the sample at desired positions through the fiber tip aperture. The sample was developed in AZ 400K developer for 30 s and rinsed in DI water. A promising tip-to-tip scanning technique for characterization of metal-coated fiber tips with aperture at the apex was presented. Nearly-circular aperture shapes were documented from NSOM measurements with diameter estimated to be less than 460 nm. By knowing the source-detector distance and the FWHM of the near-field intensity profile, the tip-to-tip scan proves an easy and fast method to analyze the fiber tip aperture properties. The fiber tip resolution was confirmed by preparation of 2D planar structures in thin photoresist layer, where the NSOM lithography uses the metal-coated fiber tip characterized in previous section. (authors)

  1. Tipping Point

    Medline Plus

    Full Text Available ... fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash format. Almost ... accidents involving young children and furniture, appliance and tv tip-overs. The force of a large television ...

  2. Tipping Point

    Medline Plus

    Full Text Available ... of a large television falling from tipping furniture can be staggering. A 50 lb. TV falls with ... story of a building. That kind of impact can kill a child or cause severe injuries. About ...

  3. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  4. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely and effectively use your CPAP device. Category Education License Standard YouTube License Show more Show ...

  5. CPAP Tips

    Medline Plus

    Full Text Available ... opinion count. Sign in ... and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ...

  6. Tipping Point

    Medline Plus

    Full Text Available ... third story of a building. That kind of impact can kill a child or cause severe injuries. ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit ...

  7. Atomic force microscopy and Langmuir-Blodgett monolayer technique to assess contact lens deposits and human meibum extracts.

    Science.gov (United States)

    Hagedorn, Sarah; Drolle, Elizabeth; Lorentz, Holly; Srinivasan, Sruthi; Leonenko, Zoya; Jones, Lyndon

    2015-01-01

    The purpose of this exploratory study was to investigate the differences in meibomian gland secretions, contact lens (CL) lipid extracts, and CL surface topography between participants with and without meibomian gland dysfunction (MGD). Meibum study: Meibum was collected from all participants and studied via Langmuir-Blodgett (LB) deposition with subsequent Atomic Force Microscopy (AFM) visualization and surface roughness analysis. CL Study: Participants with and without MGD wore both etafilcon A and balafilcon A CLs in two different phases. CL lipid deposits were extracted and analyzed using pressure-area isotherms with the LB trough and CL surface topographies and roughness values were visualized using AFM. Meibum study: Non-MGD participant meibum samples showed larger, circular aggregates with lower surface roughness, whereas meibum samples from participants with MGD showed more lipid aggregates, greater size variability and higher surface roughness. CL Study: Worn CLs from participants with MGD had a few large tear film deposits with lower surface roughness, whereas non-MGD participant-worn lenses had many small lens deposits with higher surface roughness. Balafilcon A pore depths were shallower in MGD participant worn lenses when compared to non-MGD participant lenses. Isotherms of CL lipid extracts from MGD and non-MGD participants showed a seamless rise in surface pressure as area decreased; however, extracts from the two different lens materials produced different isotherms. MGD and non-MGD participant-worn CL deposition were found to differ in type, amount, and pattern of lens deposits. Lipids from MGD participants deposited irregularly whereas lipids from non-MGD participants showed more uniformity. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  8. [Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].

    Science.gov (United States)

    Jurowski, Piotr

    2005-01-01

    Presentation of the case of the pseudophakic patient in whom 3 months after uncomplicated phacoemulsification severe capsule contraction syndrome, followed by equatorial capsule fibrosis, 240 degree zonular dialysis, and spontaneous in-the-bag intraocular lens subluxation, were observed. Consecutive surgical intervention consisting of simplified transscleral "free haptic" through the capsule fixation and additional plastic of phimotic capsulorrhexis allowed to restore the best corrected visual acuity to 20/25.

  9. Mechanical properties of nickel-titanium archwire used in the final treatment phase of Tip-Edge Plus technique: an in vitro study.

    Science.gov (United States)

    Shen, Xiao; Sun, Xin-hua; Tian, Hua; Zhang, Chun-bo; Yan, Kuo; Guo, Yong-liang

    2013-01-01

    As the only active component in final treatment phase of Tip-Edge Plus technique, the activation of nickel-titanium orthodontic archwires is one of the factors that affect the torque expression. It is necessary to evaluate the mechanical properties of the nickel-titanium wire used in the final treatment phase in simulated oral environments to forecast the treatment outcomes. The mechanical properties of 171 thermal nickel-titanium wires of 0.35 mm (0.014-in) in diameters with different deflection of 40 mm in length were investigated with three-point bending test. The samples were divided into 2 groups: as-received and bended groups. In the bended group, samples were divided into 7 subgroups according to the amounts of deflection and named by the canine angulations (-25°, -19°, -13°, -7°, -1°, +5°, +11°). The deflection of wires was made by inserting the wires into the deep tunnel of Tip-Edge Plus brackets positioned in plaster casts with different canine angulations to mimic the use of nickel-titanium wires in the final treatment phase. Immersed the bended group in artificial saliva (pH 6.8) and preserved at 37.0°C. Eight durations of incubation were tested: 1 to 8 weeks. Three analogous samples of each group and subgroups were tested per week. Stiffness (YS:E) and the load-deflection characteristics of unloading plateau section were obtained. Significant changes in specific mechanical properties were observed in long-term immersed and large deflected wires compared with as-received groups. Both immersion time and deflection affected the mechanical properties of wires in the simulated oral environment, and the two factors had synergistic effect. In groups -25°, -19° and -13°, stiffness (YS:E) increased then decreased and average plateau force and ratio of variance decreased then increased correspondingly at specific time. In the final treatment phase of Tip-Edge Plus technique, the mechanical properties of nickel-titanium wire are associated with the

  10. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  11. Tips of the dual-lumen microcatheter-facilitated reverse wire technique in percutaneous coronary interventions for markedly angulated bifurcated lesions.

    Science.gov (United States)

    Nomura, Tetsuya; Kikai, Masakazu; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Sugimoto, Takeshi; Keira, Natsuya; Tatsumi, Tetsuya

    2018-04-01

    In practical settings of percutaneous coronary intervention (PCI), we sometimes encounter difficulty in introducing a guidewire (GW) to the markedly angulated side branch (SB), and the reverse wire technique is considered as a last resort to overcome such a situation. We analyzed 12 cases that underwent PCI with dual-lumen microcatheter-facilitated reverse wire technique between January 2013 and July 2016. We retrospectively investigated the lesion's characteristics and the details of the PCI procedures, and discussed tips about the use of this technique. The SB that exhibits both a smaller take-off angle and a larger carina angle is considered to be the most suitable candidate for this technique. The first step of this technique involves the delivery of the reverse wire system to the target bifurcation. However, most cases exhibit significant stenosis proximal to the bifurcation, which often hampers the delivery of the reverse wire system. Because the sharply curved reverse wire system is easier to pass the stenosis as compared to the roundly curved system, we recommend a sharp curve should be adopted for this technique. On the other hand, it is sure that device delivery is much easier on the GW with a round curve as compared to that with a sharp curve. Therefore, it is important to modify the details of this procedure on a case-by-case basis according to the lesion's characteristics.

  12. Analysis of initial changes in the proteins of soybean root tip under flooding stress using gel-free and gel-based proteomic techniques.

    Science.gov (United States)

    Yin, Xiaojian; Sakata, Katsumi; Nanjo, Yohei; Komatsu, Setsuko

    2014-06-25

    Flooding has a severe negative effect on soybean cultivation in the early stages of growth. To obtain a better understanding of the response mechanisms of soybean to flooding stress, initial changes in root tip proteins under flooding were analyzed using two proteomic techniques. Two-day-old soybeans were treated with flooding for 3, 6, 12, and 24h. The weight of soybeans increased during the first 3h of flooding, but root elongation was not observed. Using gel-based and gel-free proteomic techniques, 115 proteins were identified in root tips, of which 9 proteins were commonly detected by both methods. The 71 proteins identified by the gel-free proteomics were analyzed by a hierarchical clustering method based on induction levels during the flooding, and the proteins were divided into 5 clusters. Additional interaction analysis of the proteins revealed that ten proteins belonging to cluster I formed the center of a protein interaction network. mRNA expression analysis of these ten proteins showed that citrate lyase and heat shock protein 70 were down-regulated, whereas calreticulin was up-regulated in initial phase of flooding. These results suggest that flooding stress to soybean induces calcium-related signal transduction, which might play important roles in the early responses to flooding. Flooding has a severe negative effect on soybean cultivation, particularly in the early stages of growth. To better understand the response mechanisms of soybean to the early stages of flooding stress, two proteomic techniques were used. Two-day-old soybeans were treated without or with flooding for 3, 6, 12, and 24h. The fresh weight of soybeans increased during the first 3h of flooding stress, but the growth then slowed and no root elongation was observed. Using gel-based and gel-free proteomic techniques, 115 proteins were identified in root tips, of which 9 proteins were commonly detected by both methods. The 71 proteins identified by the gel-free proteomics were analyzed

  13. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  14. CPAP Tips

    Medline Plus

    Full Text Available ... Get YouTube Red. Working... Not now Try it free Find out why Close CPAP Tips from FDA ... safely and effectively use your CPAP device. Category Education License Standard YouTube License Show more Show less ...

  15. Tipping Point

    Medline Plus

    Full Text Available ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit other Web Sites Maintained by CPSC: cpsc.gov| poolsafely.gov| recalls.gov| saferproducts.gov Privacy, Security, and Legal Notice | Accessibility Policy | Open Government @ ...

  16. CPAP Tips

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close CPAP Tips from ...

  17. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely and effectively use your CPAP device. Category ... Ambulance Service 21,588 views 4:34 Obstructive Sleep Apnea ...

  18. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ... Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign in to add ...

  19. Productivity tips for developers

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    I like to read about productivity tools and techniques, but the problem is - most of them are completely overrated, the tips are not that useful or they are too difficult to implement. But, sometimes I can find some stuff that really makes me think "damn, how could I live without this before?!". Today, I would like to share some of them and hopefully hear about the tips and tricks that you use. Maybe we can find a way to share them somehow (github repo/forum)?

  20. Modulation of physical and biological properties of a composite PLLA and polyaspartamide derivative obtained via thermally induced phase separation (TIPS) technique

    Energy Technology Data Exchange (ETDEWEB)

    Carfì Pavia, Francesco [Department of Civil, Environmental, Aerospace, Materials Engineering, University of Palermo, 90142 Palermo (Italy); Palumbo, Fabio Salvatore, E-mail: fabiosalvatore.palumbo@unipa.it [Dipartimento di Scienze e Tecnologie Biologiche Chimiche e Farmaceutiche, Sezione di Chimica e Tecnologie Farmaceutiche, Università degli Studi di Palermo, Via Archirafi 32, 90123 Palermo (Italy); La Carrubba, Vincenzo [Department of Civil, Environmental, Aerospace, Materials Engineering, University of Palermo, 90142 Palermo (Italy); Istituto Euro Mediterraneo di Scienza e Tecnologia (IEMEST) Via Michele Miraglia, 20 - 90139, Palermo (Italy); Bongiovì, Flavia [Dipartimento di Scienze e Tecnologie Biologiche Chimiche e Farmaceutiche, Sezione di Chimica e Tecnologie Farmaceutiche, Università degli Studi di Palermo, Via Archirafi 32, 90123 Palermo (Italy); Brucato, Valerio [Department of Civil, Environmental, Aerospace, Materials Engineering, University of Palermo, 90142 Palermo (Italy); Pitarresi, Giovanna; Giammona, Gaetano [Dipartimento di Scienze e Tecnologie Biologiche Chimiche e Farmaceutiche, Sezione di Chimica e Tecnologie Farmaceutiche, Università degli Studi di Palermo, Via Archirafi 32, 90123 Palermo (Italy)

    2016-10-01

    In the present study, blend of poly L-lactic acid (PLLA) with a graft copolymer based on α,β-poly(N-hydroxyethyl)-DL-aspartamide and PLA named PHEA-PLA, has been used to design porous scaffold by using Thermally Induced Phase Separation (TIPS) technique. Starting from a homogeneous ternary solution of polymers, dioxane and deionised water, PLLA/PHEA-PLA porous foams have been produced by varying the polymers concentration and de-mixing temperature in metastable region. Results have shown that scaffolds prepared with a polymer concentration of 4% and de-mixing temperature of 22.5 °C are the best among those assessed, due to their optimal pore size and interconnection. SEM and DSC analysis have been carried out respectively to study scaffold morphology and the influence of PHEA-PLA on PLLA crystallization, while DMF extraction has been carried out in order to quantify PHEA-PLA into the final scaffolds. To evaluate scaffold biodegradability, a hydrolysis study has been performed until 56 days by incubating systems in a media mimicking physiological environment (pH 7.4). Results obtained have highlighted a progressive increase in weight loss with time in PLLA/PHEA-PLA scaffolds, conceivably due to the presence of PHEA-PLA and polymers interpenetration. Viability and adhesion of bovine chondrocytes seeded on the scaffolds have been studied by MTS test and SEM analysis. From results achieved it appears that the presence of PHEA-PLA increases cells affinity, allowing a faster adhesion and proliferation inside the scaffold. - Highlights: • Blended scaffolds of PLLA and PHEA-PLA were successfully obtained with TIPS technique. • Scaffolds with an open porosity and a good interconnection were formed. • PHEA-PLA improved water affinity accelerating rate of hydrolysis of blended scaffold. • Preliminary assay suggests that PHEA-PLA improved chondrocytes uptake and viability.

  1. Modulation of physical and biological properties of a composite PLLA and polyaspartamide derivative obtained via thermally induced phase separation (TIPS) technique

    International Nuclear Information System (INIS)

    Carfì Pavia, Francesco; Palumbo, Fabio Salvatore; La Carrubba, Vincenzo; Bongiovì, Flavia; Brucato, Valerio; Pitarresi, Giovanna; Giammona, Gaetano

    2016-01-01

    In the present study, blend of poly L-lactic acid (PLLA) with a graft copolymer based on α,β-poly(N-hydroxyethyl)-DL-aspartamide and PLA named PHEA-PLA, has been used to design porous scaffold by using Thermally Induced Phase Separation (TIPS) technique. Starting from a homogeneous ternary solution of polymers, dioxane and deionised water, PLLA/PHEA-PLA porous foams have been produced by varying the polymers concentration and de-mixing temperature in metastable region. Results have shown that scaffolds prepared with a polymer concentration of 4% and de-mixing temperature of 22.5 °C are the best among those assessed, due to their optimal pore size and interconnection. SEM and DSC analysis have been carried out respectively to study scaffold morphology and the influence of PHEA-PLA on PLLA crystallization, while DMF extraction has been carried out in order to quantify PHEA-PLA into the final scaffolds. To evaluate scaffold biodegradability, a hydrolysis study has been performed until 56 days by incubating systems in a media mimicking physiological environment (pH 7.4). Results obtained have highlighted a progressive increase in weight loss with time in PLLA/PHEA-PLA scaffolds, conceivably due to the presence of PHEA-PLA and polymers interpenetration. Viability and adhesion of bovine chondrocytes seeded on the scaffolds have been studied by MTS test and SEM analysis. From results achieved it appears that the presence of PHEA-PLA increases cells affinity, allowing a faster adhesion and proliferation inside the scaffold. - Highlights: • Blended scaffolds of PLLA and PHEA-PLA were successfully obtained with TIPS technique. • Scaffolds with an open porosity and a good interconnection were formed. • PHEA-PLA improved water affinity accelerating rate of hydrolysis of blended scaffold. • Preliminary assay suggests that PHEA-PLA improved chondrocytes uptake and viability.

  2. DISSECTING THE GRAVITATIONAL LENS B1608+656. I. LENS POTENTIAL RECONSTRUCTION

    NARCIS (Netherlands)

    Suyu, S. H.; Marshall, P. J.; Blandford, R. D.; Fassnacht, C. D.; Koopmans, L. V. E.; McKean, J. P.; Treu, T.

    2009-01-01

    Strong gravitational lensing is a powerful technique for probing galaxy mass distributions and for measuring cosmological parameters. Lens systems with extended source-intensity distributions are particularly useful for this purpose since they provide additional constraints on the lens potential (

  3. Tip enhancement

    CERN Document Server

    Kawata, Satoshi

    2007-01-01

    This book discusses the recent advances in the area of near-field Raman scattering, mainly focusing on tip-enhanced and surface-enhanced Raman scattering. Some of the key features covered here are the optical structuring and manipulations, single molecule sensitivity, analysis of single-walled carbon nanotubes, and analytic applications in chemistry, biology and material sciences. This book also discusses the plasmonic materials for better enhancement, and optical antennas. Further, near-field microscopy based on second harmonic generation is also discussed. Chapters have been written by some of the leading scientists in this field, who present some of their recent work in this field.·Near-field Raman scattering·Tip-enhanced Raman spectroscopy·Surface-enhanced Raman spectroscopy·Nano-photonics·Nanoanalysis of Physical, chemical and biological materials beyond the diffraction limits·Single molecule detection

  4. (Allium cepa) root tip mitosis

    African Journals Online (AJOL)

    Aghomotsegin

    their chemical composition and genotoxic effects on cell reproduction. Two petrochemicals, air ... the chromosomes of the individual cells of the root tip could be a pointer to their ..... Chromosome technique: Theory and. Practice. Butterworths ...

  5. Screening for sweet potato (Ipomoea batatas (L.)) viruses and their elimination using thermotheraphy-meristem tip culture technique

    International Nuclear Information System (INIS)

    Arkorful, E.

    2012-11-01

    Despite its high potential for food security, production of sweet potato is constrained by viruses which reduce yield by 90%. It is therefore essential to screen for, identify and eliminate these viruses in elite clones before dissemination to farmers. In this study, visual symptomatology and PCR-based techniques were used to identify sweet potato viruses. Visual symptomatology revealed virus associated symptoms ranging from vein clearing, interveinal chlorosis, chlorotic spots, upward curling on leaf edges, leaf narrowing and distortion, purpling, blistering, reduction of the leaf blades and general leaf yellowing in all 22 accessions grown on the field. Disease Incidence (DI) significantly (p≤0.05) varied between accessions with US003 having the lowest (20%) while ten accessions had 90% DI at the end of the study. Index of symptom severity of all plants (ISSap) ranged from 1.08±0.09 to 3.67 ±0.11 with VOTCR003 having the lowest suggesting that it is a moderately susceptible accession while VOTCR002 had the highest suggesting that it is susceptible to viral diseases. Contrarily, index of symptom severity of diseased plants (ISSdp) ranged from 2.00±0.25 to 3.75±0.32. The accession VOTCR002 had the highest ISSdp. Visual symptomatology showed that VOTCR002 had the highest DI, ISSap and ISSdp suggesting that it is highly susceptible to viral diseases. Ten severely infected accessions were tested for Sweet Potato leaf curl virus (SPLCV), Sweet Potato chlorotic stunt virus (SPCSV), Sweet potato feathery mottle virus (SPFMV) and Sweet Potato mild mottle virus (SPMMV) using PCR and RT-PCR techniques. RT-PCR did not amplify any of the virus genomes due to prolonged storage enzymes, In contrast, PCR detected SPLCV in 30% of the accessions. Plants infected with SPLCV were grown in the chamber at 35 degrees celsius for 4 weeks followed by meristem top culture. The regenerants were indexed after ten weeks for SPLCV. Fifty two percent (52.385 od the regenerants were

  6. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory of probabil...

  7. SU-E-J-11: Measurement of Eye Lens Dose for Varian On-Board Imaging with Different CBCT Acquisition Techniques

    International Nuclear Information System (INIS)

    Deshpande, S; Dhote, D; Kumar, R; Thakur, K

    2015-01-01

    Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens doses were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT

  8. Lifting Safety: Tips To Help Prevent Back Injuries

    Science.gov (United States)

    ... Prevent Back Injuries Lifting Safety: Tips to Help Prevent Back Injuries Share Print Back injuries are common problems at work, home, and play. They can be caused by accidents or improper lifting technique. Below are tips to ...

  9. Converging or Diverging Lens?

    Science.gov (United States)

    Branca, Mario

    2013-01-01

    Why does a lens magnify? Why does it shrink objects? Why does this happen? The activities that we propose here are useful in helping us to understand how lenses work, and they show that the same lens can have different magnification capabilities. A converging lens can also act as a diverging lens. (Contains 4 figures.)

  10. Near-field microscopy with a microfabricated solid immersion lens

    Science.gov (United States)

    Fletcher, Daniel Alden

    2001-07-01

    Diffraction of focused light prevents optical microscopes from resolving features in air smaller than half the wavelength, λ Spatial resolution can be improved by passing light through a sub-wavelength metal aperture scanned close to a sample, but aperture-based probes suffer from low optical throughput, typically below 10-4. An alternate and more efficient technique is solid immersion microscopy in which light is focused through a high refractive index Solid Immersion Lens (SIL). This work describes the fabrication, modeling, and use of a microfabricated SIL to obtain spatial resolution better than the diffraction limit in air with high optical throughput for infrared applications. SILs on the order of 10 μm in diameter are fabricated from single-crystal silicon and integrated onto silicon cantilevers with tips for scanning. We measure a focused spot size of λ/5 with optical throughput better than 10-1 at a wavelength of λ = 9.3 μm. Spatial resolution is improved to λ/10 with metal apertures fabricated directly on the tip of the silicon SIL. Microlenses have reduced spherical aberration and better transparency than large lenses but cannot be made arbitrarily small and still focus. We model the advantages and limitations of focusing in lenses close to the wavelength in diameter using an extension of Mie theory. We also investigate a new contrast mechanism unique to microlenses resulting from the decrease in field-of-view with lens diameter. This technique is shown to achieve λ/4 spatial resolution. We explore applications of the microfabricated silicon SIL for high spatial resolution thermal microscopy and biological spectroscopy. Thermal radiation is collected through the SIL from a heated surface with spatial resolution four times better than that of a diffraction- limited infrared microscope. Using a Fourier-transform infrared spectrometer, we observe absorption peaks in bacteria cells positioned at the focus of the silicon SIL.

  11. Tips on Blood Testing

    Science.gov (United States)

    ... Test Pain, Discomfort and Anxiety Tips to Help Children through Their Medical Tests Tips to Help the Elderly through Their Medical Tests Find Us On Social Media: Facebook Twitter Google Plus Footer Menu Home About ...

  12. The TIPS Liquidity Premium

    DEFF Research Database (Denmark)

    Andreasen, Martin Møller; Christensen, Jens H.E.; Simon Riddell, Simon

    We introduce an arbitrage-free term structure model of nominal and real yields that accounts for liquidity risk in Treasury inflation-protected securities (TIPS). The novel feature of our model is to identify liquidity risk from individual TIPS prices by accounting for the tendency that TIPS, lik...

  13. Tip studies using CFD and comparison with tip loss models

    DEFF Research Database (Denmark)

    Hansen, Martin Otto Laver; Johansen, J.

    2004-01-01

    The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD......The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD...

  14. Study of tip loss corrections using CFD rotor computations

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zhu, Wei Jun; Sørensen, Jens Nørkær

    2014-01-01

    Tip loss correction is known to play an important role for engineering prediction of wind turbine performance. There are two different types of tip loss corrections: tip corrections on momentum theory and tip corrections on airfoil data. In this paper, we study the latter using detailed CFD...... computations for wind turbines with sharp tip. Using the technique of determination of angle of attack and the CFD results for a NordTank 500 kW rotor, airfoil data are extracted and a new tip loss function on airfoil data is derived. To validate, BEM computations with the new tip loss function are carried out...... and compared with CFD results for the NordTank 500 kW turbine and the NREL 5 MW turbine. Comparisons show that BEM with the new tip loss function can predict correctly the loading near the blade tip....

  15. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  16. Single lens to lens duplication: The missing link

    OpenAIRE

    Bhatt, Rupal; Jethani, Jitendra; Saluja, Praveen; Bharti, Vinay

    2008-01-01

    Congenital anomalies of the lens include a wide range from lens coloboma to primary aphakia and doubling of lens. There have been few case reports of double lens; the etiology suggested is metaplastic changes in the surface ectoderm that leads to formation of two lens vesicles and hence resulting in double lens. We report a case with bilobed lens, which raises the possibility of explaining the etiology of double lens.

  17. Bioptics in sutureless intrascleral multifocal posterior chamber intraocular lens fixation.

    Science.gov (United States)

    Pavlidis, Mitrofanis; de Ortueta, Diego; Scharioth, Gabor B

    2011-05-01

    To present a technique for sutureless fixation of a three-piece, multifocal, posterior chamber intraocular lens (IOL) in the ciliary sulcus. A 24-year-old woman presented with bilateral subluxation of the crystalline lens. Two straight sclerotomies were prepared with a 24-gauge cannula 2.0 mm from the limbus 180° apart from each other. The cannula was used to create a 2.0- to 3.0-mm tunnel parallel to the limbus starting from the sclerotomies. The leading haptic of the multifocal IOL was grasped at its tip with end-gripping, 25-gauge forceps and pulled through the sclerotomy. The forceps was used to introduce the IOL haptic into the scleral tunnel parallel to the limbus. Multifocal posterior chamber IOLs were stable and well centered. No postoperative complications occurred in the 16-month follow-up period. Preoperative astigmatism was corrected after IOL implantation with corneal wavefront-guided laser epithelial keratomileusis. Sutureless fixation of multifocal posterior chamber IOL haptics in a scleral tunnel parallel to the limbus can be successful, resulting in long-term centration and three-dimensional axial stability for optimal refractive results. If necessary, postoperative wavefront-guided refractive correction can be performed to optimize final refraction. Copyright 2011, SLACK Incorporated.

  18. The transjugular intrahepatic portosystemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Owen, A.R.; Stanley, A.J.; Vijayananthan, A.; Moss, J.G.

    2009-01-01

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  19. The transjugular intrahepatic portosystemic shunt (TIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Owen, A.R. [Department of Radiology, Austin Health, Heidelberg, Melbourne (Australia)], E-mail: andrewowen@doctors.org.uk; Stanley, A.J. [Department of Gastroenterology, Glasgow Royal Infirmary, Glasgow (United Kingdom); Vijayananthan, A. [Department of Biomedical Imaging, University of Malaya, Kuala Lumpur (Malaysia); Moss, J.G. [Department of Radiology, Gartnavel General Hospital, Glasgow (United Kingdom)

    2009-07-15

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  20. Optimized lens-sparing treatment of retinoblastoma with electron beams

    NARCIS (Netherlands)

    Steenbakkers, RJHM; Altschuler, MD; DAngio, GJ; Goldwein, JW; Kassaee, A

    1997-01-01

    Purpose: The ideal lens-sparing radiotherapy technique for retinoblastoma calls for 100% dose to the entire retina including the ora serrata and zero dose to the lens, Published techniques, most of which use photons, have not accomplished this ideal treatment. We describe here a technique that

  1. Aberration design of zoom lens systems using thick lens modules.

    Science.gov (United States)

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  2. Enhanced thermal lens effect in gold nanoparticle-doped Lyotropic liquid crystal by nanoparticle clustering probed by Z-scan technique

    International Nuclear Information System (INIS)

    Gomez, S.L.; Lenart, V.M.

    2015-01-01

    This work presents an experimental study of the thermal lens effect in Au nanoparticles-doped lyotropic liquid crystals under cw 532 nm optical excitation. Spherical Au nanoparticles of about 12 nm were prepared by Turkevich’s method, and the lyotropic liquid crystal was a ternary mixture of SDS, 1-DeOH, and water that exhibits an isotropic phase at room temperature. The lyotropic matrix induces aggregation of the nanoparticles, leading to a broad and a red-shifted surface plasmon resonance. The thermal nonlinear optical refraction coefficient n 2 increases as a power of number density of nanoparticles, being possible to address this behavior to nanoparticle clustering. (author)

  3. Enhanced thermal lens effect in gold nanoparticle-doped Lyotropic liquid crystal by nanoparticle clustering probed by Z-scan technique

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, S.L.; Lenart, V.M., E-mail: sgomez@uepg.br [Universidade Estadual de Ponta Grossa (UEPG), PR (Brazil). Dept. de Fisica; Turchiello, R.T. [Universidade Federal Tecnologica do Parana (UFTPR), Ponta Grossa, PR (Brazil). Dept. de Fisica; Goya, G.F. [Department of Condensed Matter Physics, Aragon Institute of Nanoscience, Zaragoza (Spain)

    2015-10-01

    This work presents an experimental study of the thermal lens effect in Au nanoparticles-doped lyotropic liquid crystals under cw 532 nm optical excitation. Spherical Au nanoparticles of about 12 nm were prepared by Turkevich’s method, and the lyotropic liquid crystal was a ternary mixture of SDS, 1-DeOH, and water that exhibits an isotropic phase at room temperature. The lyotropic matrix induces aggregation of the nanoparticles, leading to a broad and a red-shifted surface plasmon resonance. The thermal nonlinear optical refraction coefficient n{sub 2} increases as a power of number density of nanoparticles, being possible to address this behavior to nanoparticle clustering. (author)

  4. The retro-cut process: precision reshaping of magnetic quadrupole lens profiles to improve field strength

    International Nuclear Information System (INIS)

    Szymanski, Roland; Jamieson, David N.; Rout, Bibhudutta; Brenn, Ruediger

    2005-01-01

    In the evolution of magnetic quadrupole lens technology for nuclear microprobe systems, the pole profile has seen several improvements that have led to increases in the pole tip field for a given lens current. In a design dating from prior to 1994 the magnetic field strength was compromised by pole tip extensions that allowed significant flux leakage away from the central bore of the lens. There are many similar lenses in use world wide and they have a weaker focusing action compared to more modern designs which omit the pole tip extensions. We demonstrate that these pre-1994 lenses can have a new profile cut into the pole tip using a precision wire cutting machine that does not require the lens to be dismantled and does not compromise the purity of the lens field. We present the results of applying this process to lenses 1 and 4 in the antisymmetric quadruplet nuclear microprobe system at the University of Freiburg. The grid shadow method was used to show lens quality was not compromised by the process and we find that the lens field strength for a given current is increased by 15% when used to focus 2 MeV H + ions in the antisymmetric quadruplet

  5. Magnetic elements for switching magnetization magnetic force microscopy tips

    International Nuclear Information System (INIS)

    Cambel, V.; Elias, P.; Gregusova, D.; Martaus, J.; Fedor, J.; Karapetrov, G.; Novosad, V.

    2010-01-01

    Using combination of micromagnetic calculations and magnetic force microscopy (MFM) imaging we find optimal parameters for novel magnetic tips suitable for switching magnetization MFM. Switching magnetization MFM is based on two-pass scanning atomic force microscopy with reversed tip magnetization between the scans. Within the technique the sum of the scanned data with reversed tip magnetization depicts local atomic forces, while their difference maps the local magnetic forces. Here we propose the design and calculate the magnetic properties of tips suitable for this scanning probe technique. We find that for best performance the spin-polarized tips must exhibit low magnetic moment, low switching fields, and single-domain state at remanence. The switching field of such tips is calculated and optimum shape of the Permalloy elements for the tips is found. We show excellent correspondence between calculated and experimental results for Py elements.

  6. ADHD: Tips to Try

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español ADHD: Tips to Try KidsHealth / For Teens / ADHD: Tips to Try Print en español TDAH: Consejos que puedes probar ADHD , short for attention deficit hyperactivity disorder , is a ...

  7. Total Telephone Tips.

    Science.gov (United States)

    Corder, Lloyd E.; And Others

    This manual of telephone behavior tips for business and sales professionals offers ways to handle the disgruntled caller and makes suggestions on topics relevant to the telephone. The manual is divided into the following sections and subsections: (1) Common Courtesy (staff tips, answering the telephone, screening calls, transferring calls, taking…

  8. Tip Cells in Angiogenesis

    NARCIS (Netherlands)

    M.G. Dallinga (Marchien); S.E.M. Boas (Sonja); I. Klaassen (Ingeborg); R.M.H. Merks (Roeland); C.J.F. van Noorden; R.O. Schlingemann (Reinier)

    2015-01-01

    htmlabstractIn angiogenesis, the process in which blood vessel sprouts grow out from a pre-existing vascular network, the so-called endothelial tip cells play an essential role. Tip cells are the leading cells of the sprouts; they guide following endothelial cells and sense their environment for

  9. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  10. Tip-Based Nanofabrication for Scalable Manufacturing

    Directory of Open Access Journals (Sweden)

    Huan Hu

    2017-03-01

    Full Text Available Tip-based nanofabrication (TBN is a family of emerging nanofabrication techniques that use a nanometer scale tip to fabricate nanostructures. In this review, we first introduce the history of the TBN and the technology development. We then briefly review various TBN techniques that use different physical or chemical mechanisms to fabricate features and discuss some of the state-of-the-art techniques. Subsequently, we focus on those TBN methods that have demonstrated potential to scale up the manufacturing throughput. Finally, we discuss several research directions that are essential for making TBN a scalable nano-manufacturing technology.

  11. Tip-Based Nanofabrication for Scalable Manufacturing

    International Nuclear Information System (INIS)

    Hu, Huan; Somnath, Suhas

    2017-01-01

    Tip-based nanofabrication (TBN) is a family of emerging nanofabrication techniques that use a nanometer scale tip to fabricate nanostructures. Here in this review, we first introduce the history of the TBN and the technology development. We then briefly review various TBN techniques that use different physical or chemical mechanisms to fabricate features and discuss some of the state-of-the-art techniques. Subsequently, we focus on those TBN methods that have demonstrated potential to scale up the manufacturing throughput. Finally, we discuss several research directions that are essential for making TBN a scalable nano-manufacturing technology.

  12. Safety Tips: Basketball (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Safety Tips: Basketball KidsHealth / For Parents / Safety Tips: Basketball ... make sure they follow these tips. Why Basketball Safety Is Important Fortunately, very few basketball injuries are ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver). Portal hypertension can also occur in children, although children are much less likely to require a TIPS. ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  14. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  15. Recanalization strategy for chronic total occlusions with tapered and stiff-tip guidewire. The results of CTO new techniQUE for STandard procedure (CONQUEST) trial.

    Science.gov (United States)

    Mitsudo, Kazuaki; Yamashita, Takehiro; Asakura, Yasushi; Muramatsu, Toshiya; Doi, Osamu; Shibata, Yoshisato; Morino, Yoshihiro

    2008-11-01

    The success rate of percutaneous coronary intervention (PCI) for chronic total coronary occlusion (CTO) lesions varies depending on the guidewire manipulation skills of the operator. The standardization of guidewire technique is very important. A new technique with a new tapered wire (Conquest, Confianza Pro) was tested to verify effectiveness for higher initial success rates and standardization of PCI for CTO. A prospective, multicenter registry was conducted at 6 investigational sites. In the CONQUEST trial, The CTO lesions were treated by using an intermediate guidewire to cross the lesion. If it did not cross, the guidewire was changed to the Conquest guidewire. If it did not cross, "seesaw-wiring" or the "parallel-wire technique" was performed. The primary endpoint was the initial procedural success rate. A total of 110 patients representing 116 CTO lesions were treated from July 2003 through March 2004. The procedural success rate was 86.2% on the first try, and 88.8% on the second try, respectively. The guidewire success rate on the second try was 90.5% during the hospital stay; no deaths, or acute myocardial infarctions were confirmed. Two patients deteriorated into tamponade, and surgical or percutaneous drainage was performed in each patient without any sequelae. A guidewire technique in PCI for CTOs that starts with the intermediate guidewire and moves to the Confianza Pro tapered guidewire, either alone or by performing a see-saw or parallel-wire technique, can achieve a high initial success rate with an acceptably low major complication rate.

  16. Lightning Safety Tips and Resources

    Science.gov (United States)

    ... Services Careers Contact Us Glossary Safety National Program Lightning Safety Tips and Resources Weather.gov > Safety > Lightning Safety Tips and Resources Lightning Resources Lightning strikes ...

  17. Abscisic Acid Stimulates Elongation of Excised Pea Root Tips

    Science.gov (United States)

    Gaither, Douglas H.; Lutz, Donald H.; Forrence, Leonard E.

    1975-01-01

    Excised Pisum sativum L. root tips were incubated in a pH 5.2 sucrose medium containing abscisic acid. Elongation growth was inhibited by 100 μm abscisic acid. However, decreasing the abscisic acid concentration caused stimulation of elongation, the maximum response (25% to 30%) occurring at 1 μm abscisic acid. Prior to two hours, stimulation of elongation by 1 μm abscisic acid was not detectable. Increased elongation did not occur in abscisic acid-treated root tips of Lens culinaris L., Phaseolus vulgaris L., or Zea mays L. PMID:16659198

  18. Low Vision Tips

    Science.gov (United States)

    ... this page: https://medlineplus.gov/lowvision.html MedlinePlus: Low Vision Tips We are sorry. MedlinePlus no longer maintains the For Low Vision Users page. You will still find health resources ...

  19. Diabetes: Dental Tips

    Science.gov (United States)

    Diabetes: Dental Tips For more copies contact: National Institute of Dental and Craniofacial Research National Oral Health Information Clearinghouse ... damage the gum and bone that hold your teeth in place and may lead to painful chewing ...

  20. Incontinence Treatment: Dietary Tips

    Science.gov (United States)

    ... helpful, please consider supporting IFFGD with a small tax-deductible donation. Lifestyle Changes Dietary Tips Medication Bowel ... arises requiring an expert’s care. © Copyright 1998-2018 International Foundation for Functional Gastrointestinal Disorders, Inc. (IFFGD). All ...

  1. Capsular 'pits' in the human lens.

    OpenAIRE

    Harris, M. L.; Brown, N. A.; Shun-Shin, G. A.; Smith, G. T.

    1992-01-01

    The lens capsule is an atypical basement membrane surrounding the lens epithelial cells and lens fibres which make up the remainder of the human lens. A seemingly unreported morphological change visible in the lens capsule with the biomicroscope is described.

  2. Dielectrophoretic positioning of single nanoparticles on atomic force microscope tips for tip-enhanced Raman spectroscopy.

    Science.gov (United States)

    Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang

    2015-05-01

    Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Particle swarm optimization applied to automatic lens design

    Science.gov (United States)

    Qin, Hua

    2011-06-01

    This paper describes a novel application of Particle Swarm Optimization (PSO) technique to lens design. A mathematical model is constructed, and merit functions in an optical system are employed as fitness functions, which combined radiuses of curvature, thicknesses among lens surfaces and refractive indices regarding an optical system. By using this function, the aberration correction is carried out. A design example using PSO is given. Results show that PSO as optical design tools is practical and powerful, and this method is no longer dependent on the lens initial structure and can arbitrarily create search ranges of structural parameters of a lens system, which is an important step towards automatic design with artificial intelligence.

  4. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, Mike A. (Albuquerque, NM); Foreman, Larry R. (Los Alamos, NM)

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  5. Intraocular lens fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  6. Bent versus straight tips in micropulsed longitudinal phacoemulsification.

    Science.gov (United States)

    Stagg, Brian C; Gupta, Isha; Cahoon, Judd; Ronquillo, Cecinio; Shi, Dallas; Zaugg, Brian; Gardiner, Gareth; Barlow, William R; Pettey, Jeff H; Aabid Farukhi, M; Jensen, Jason; Olson, Randall J

    2015-10-01

    The aim of this study was to evaluate bent and straight phacoemulsification tips to determine which tip is more efficient in removal of lens fragments, using micropulsed longitudinal ultrasound in phacoemulsification. In vitro laboratory study. The John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, was the study setting. Pig lenses hardened in a manner comparable with dense human cataracts were cut into 2-mm cubes and removed with micropulsed longitudinal ultrasound using settings previously shown to be optimally efficient (6 milliseconds on and 6 milliseconds off for a bent tip). To verify this time as most efficient for a straight tip, we also tested times of 5, 6, and 7 milliseconds time on and off. The tips were either straight or with a 20-degree bend. Twenty cubes were used for each comparative run. For the straight tip, 6 milliseconds on (1.56 ± 0.815 seconds) was significantly more efficient than 7 milliseconds on (2.45 ± 1.56 seconds, p = 0.001) and not significantly more efficient than 5 milliseconds on (1.69 ± 0.86 seconds, p = 0.43). Five milliseconds off time (1.45 ± 0.76s) was more efficient than 6 milliseconds (2.06 ± 1.37 seconds, p = 0.004) and 7 milliseconds off (2.18 ± 1.24s, p = 0.001). The straight tip was more efficient than the bent tip (1.38 ± 0.83 versus 2.93 ± 2.14 seconds, p = 0.006). Results are contrary to accepted common belief. Micropulsed longitudinal phacoemulsification is more efficient with a straight rather than a bent tip. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  7. The Acoustic Lens Design and in Vivo Use of a Multifunctional Catheter Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    Science.gov (United States)

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David

    2009-01-01

    A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850

  8. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  9. Improved flare tip design

    Energy Technology Data Exchange (ETDEWEB)

    Gogolek, P. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Energy Technology Centre

    2004-07-01

    This paper discusses the testing procedures and development of an improved flare tip design. Design objectives included performance equal to or better than utility flares at low wind speed; conversion efficiency; fuel slip; smoking; significant improvement at high wind speed; and no increase in trace emissions. A description of the testing facility of the flare tip was provided, with reference to the fact that the facility allowed for realistic near full scale gas flares in a single-pass flare test facility. Other details of the facility included: an adjustable ceiling; high capacity variable speed fan; sampling ports along working section in stack; windows along working section; and air cooled walls, floor, and ceiling. The fuels used in the flare tip included natural gas, propane, gasoline and inert gases. Details of wind speed, appurtenances and turbulence generating grids were presented, with reference to continuous gas emission measurements. A list of design constraints was provided. Flare performance included wind speed, turbulence and fuel composition. A chart of conversion inefficiencies with a correlation of wind speed and turbulence, fuel flow and pipe size was also presented. Several new tip designs were fabricated for testing, with screening tests for comparison to basic pipe and ranking designs. Significant improvements were found in one of the new designs, including results with 30 per cent propane in fuel. Emissions reduction from 10 to 35 per cent were noted. It was concluded that future work should focus on evaluating improved tip for stability at low wind speeds. Fuel slips are the primary source of emissions, and it was recommended that further research is necessary to improve existing flare tips. tabs, figs.

  10. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman’s Knot

    Directory of Open Access Journals (Sweden)

    Yong Un Shin

    2017-01-01

    Full Text Available Purpose. To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL using a single fisherman’s knot (SFK. Methods. First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. Results. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. Conclusions. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  11. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman's Knot.

    Science.gov (United States)

    Shin, Yong Un; Seong, Mincheol; Cho, Hee Yoon; Kang, Min Ho

    2017-01-01

    To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman's knot (SFK). First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage) was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  14. The lens and cataracts.

    Science.gov (United States)

    Matthews, Andrew G

    2004-08-01

    It is conservatively estimated that some form of lens opacity is present in 5% to 7% of horses with otherwise clinically normal eyes.These opacities can range from small epicapsular remnants of the fetal vasculature to dense and extensive cataract. A cataract is defined technically as any opacity or alteration in the optical homogeneity of the lens involving one or more of the following: anterior epithelium, capsule, cortex, or nucleus. In the horse, cataracts rarely involve the entire lens structure (ie, complete cataracts) and are more usually localized to one anatomic landmark or sector of the lens. Complete cataracts are invariably associated with overt and significant visual disability. Focal or incomplete cataracts alone seldom cause any apparent visual dysfunction in affected horses,however.

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but ... require the same level of care or consideration as a standard contact lens because they can be ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... With Proper Contact Lens Care Apr 23, 2018 Solar Eclipse Inflicts Damage in the Shape of the ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... valid prescription that includes the brand name, lens measurements, and expiration date. Purchase the colored contact lenses ... with human-made versions. U.S. News Highlights the Value of Ophthalmologists APR 20, 2018 By Dan T. ...

  1. Vortex gas lens

    Science.gov (United States)

    Bogdanoff, David W.; Berschauer, Andrew; Parker, Timothy W.; Vickers, Jesse E.

    1989-01-01

    A vortex gas lens concept is presented. Such a lens has a potential power density capability of 10 to the 9th - 10 to the 10th w/sq cm. An experimental prototype was constructed, and the divergence half angle of the exiting beam was measured as a function of the lens operating parameters. Reasonably good agreement is found between the experimental results and theoretical calculations. The expanded beam was observed to be steady, and no strong, potentially beam-degrading jets were found to issue from the ends of the lens. Estimates of random beam deflection angles to be expected due to boundary layer noise are presented; these angles are very small.

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  7. Research progress in TIPS shunt dysfunction and recanalization

    Directory of Open Access Journals (Sweden)

    WANG Tingting

    2015-11-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS is widely used in the treatment of cirrhotic portal hypertension and its associated complications. However, postoperative shunt dysfunction has been an important factor restricting the clinical application of TIPS. This article summarizes the use of shunt, the incidence of shunt dysfunction after TIPS, preventive measures and diagnostic methods for shunt dysfunction, and indications and techniques of shunt recanalization, in order to enhance our knowledge of shunt dysfunction and recanalization, which could further improve the efficacy of TIPS for cirrhotic portal hypertension.

  8. Efficient regeneration of plants from shoot tip explants of ...

    African Journals Online (AJOL)

    Dendrobium densiflorum Lindl. is one of the horticulturally important orchids of Nepal due to its beautiful yellowish flower and medicinal properties. The present study was carried out for plant regeneration from shoot tip explants of D. densiflorum by tissue culture technique. The shoot tip explants of this species, obtained ...

  9. Vitrectorhexis and lens aspiration with posterior chamber intraocular lens implantation in spherophakia.

    Science.gov (United States)

    Al-Haddad, Christiane; Khatib, Lama

    2012-07-01

    We describe a technique that uses the vitrector to perform successful lens aspiration and posterior chamber intraocular lens (IOL) implantation in children with spherophakia and anterior lens subluxation. After an anterior chamber maintainer is placed, the ocutome is introduced through a limbal incision to perform a circular vitrectorhexis to avoid excessive manipulation of the unstable lens followed by gentle cortex aspiration. A foldable IOL is injected into the sulcus (3-piece IOL) or bag (1-piece IOL) if the capsule is sufficiently stable. Through a pars plana incision, the ocutome is then used to perform a posterior capsulotomy to prevent late posterior capsule opacification. In our patient, sulcus IOL placement was more stable than in-the-bag placement. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Sports Dehydration Safety Tips

    Science.gov (United States)

    Sports Dehydration Safety Tips Everything you need to know to keep your kids safe from dehydration when playing sports. To keep kids in top ... to stay hydrated by drinking plenty of fluids. Dehydration occurs when a body loses more water than ...

  11. Dynamic of cold-atom tips in anharmonic potentials

    Science.gov (United States)

    Menold, Tobias; Federsel, Peter; Rogulj, Carola; Hölscher, Hendrik; Fortágh, József

    2016-01-01

    Background: Understanding the dynamics of ultracold quantum gases in an anharmonic potential is essential for applications in the new field of cold-atom scanning probe microscopy. Therein, cold atomic ensembles are used as sensitive probe tips to investigate nanostructured surfaces and surface-near potentials, which typically cause anharmonic tip motion. Results: Besides a theoretical description of this anharmonic tip motion, we introduce a novel method for detecting the cold-atom tip dynamics in situ and real time. In agreement with theory, the first measurements show that particle interactions and anharmonic motion have a significant impact on the tip dynamics. Conclusion: Our findings will be crucial for the realization of high-sensitivity force spectroscopy with cold-atom tips and could possibly allow for the development of advanced spectroscopic techniques such as Q-control. PMID:28144505

  12. Evaluation of lens dose in medulloblastoma radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, F.L.; Vilela, E.C.; Sousa, S.A; Lima, F.F. de

    2007-01-01

    The improvement of the applied radiotherapy techniques in the cranial-spinal therapy, which is used in the cases of medulloblastoma, aims the reduction of the risks of future damages in enclosed critical agencies in the irradiation fields. This work aims to evaluate the lens doses due two common techniques used in medulloblastoma radiotherapy. For this, thermoluminescent dosimeters, previously calibrated, were located in an anthropomorphic phantom (ALDERSON - RANDON Laboratory), in the tumor and lens positions. The employed techniques were as following: (1) angled fields technique and (2) half-beam block technique. The phantom was irradiated five times in each technique with two lateral opposed fields in the brain with a total prescribed dose of 1.5 Gy, followed of two posterior spinal fields with the same prescribed dose, using a 6MV accelerator. The results showed that the doses in the first technique were 0.10 +- 0,04 Gy and, in second one, 0.09 +- 0,02 Gy. It was observed that, independent of the employed technique, the lens doses practically are the same. (author)

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... or bypass, without the risks that accompany open surgery. TIPS is a minimally invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of an effect ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... then placed in this tunnel to keep the pathway open. Patients who typically need a TIPS have ... and stomach. A TIPS procedure involves creating a pathway through the liver that connects the portal vein ( ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and/or hydrothorax (in the chest). Budd-Chiari syndrome , a blockage in one or more veins that ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... filtered out by the liver. The TIPS may cause too much of these substances to bypass the ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the esophagus and stomach. A TIPS procedure involves creating a pathway through the liver that connects the ... diseases. This can result in significant challenges in creating the TIPS. top of page Additional Information and ...

  18. Tips for Living with Scleroderma

    Science.gov (United States)

    ... Patients Tips for Living Tips for Living with Scleroderma Ways to help manage your symptoms The Scleroderma ... help find improved therapies and a cure for scleroderma! Your gift today will be matched to have ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS. top of page What are some common uses of the procedure? A TIPS is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... recovery time than surgery. Your TIPS should have less of an effect than open surgical bypass on ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. ... tips and information about eye health and preserving your vision. Privacy ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ... Answers Free Newsletter Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... heart attack or stroke. Find an Ophthalmologist Advanced Search Ask an Ophthalmologist Browse Answers Free Newsletter Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Answers Free Newsletter Get ophthalmologist-reviewed tips and information about eye health and preserving your ... the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human-made versions. ... ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  7. 3D Inkjet Printed Helical Antenna with Integrated Lens

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    The gain of an antenna can be enhanced through the integration of a lens, although this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, through a unique

  8. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  9. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  10. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  11. Tip-modified Propellers

    DEFF Research Database (Denmark)

    Andersen, Poul

    1999-01-01

    The paper deals with tip-modified propellers and the methods which, over a period of two decades, have been applied to develop such propellers. The development is driven by the urge to increase the efficiency of propellers and can be seen as analogous to fitting end plates and winglets to aircraft...... propeller, have efficiency increases of a reasonable magnitude in both open-water and behind-ship conditions....

  12. Symmetric lens with extended depth of focus

    OpenAIRE

    Cho, Sung Nae

    2008-01-01

    The lens surface profile is derived based on the instantaneous focal length versus the lens radius data. The lens design based on instantaneous focal length versus the lens radius data has many useful applications in software assisted image focusing technology.

  13. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  14. Minimizing and measuring lens dose when giving cranial irradiation

    International Nuclear Information System (INIS)

    Woo, S.Y.; Donaldson, S.S.; Heck, R.J.; Nielson, K.L.; Shostak, C.

    1989-01-01

    Three different techniques of administering cranial irradiation were used to determine the dose to the lens as measured in the Rando phantom. The techniques employed were as follows: (1) the central axis of the radiation beam was placed at the thickest portion of the cranium; (2) the central axis of the radiation beam was placed at the lateral orbital rim (bon canthus); (3) the central axis of the radiation beam was placed at the thickest portion of the cranium but with the beam angled 5deg posteriorly away from the eye. Thermal luminescent dosimeters (TLD) were placed in a phantom, at a point determined from a life-sized anatomical section of the plane through the midsection of the eye, to be at the location of the posterior capsule of the lens. In addition, TLDs were placed on the outer surface of the phantom head, directly lateral to the location determined to be where the lens would lie. With equally weighted lateral opposed beams, delivering a midplane dose of 200cGy, the TLDs at the point of the lens measured 21, 9.9 and 10.6% of the midplane doses from the three techniques respectively. TLDs placed directly lateral to the lens on the surface of the phantom head gave an approximation of the lens dose, particularly when techniques 2 and 3 were used. Isodose curve generated by a General Electric treatment planning computer gave lens doses similar to those of the phantom data for each of the three different radiotherapy techniques. Cranial irradiation should be carried out by either technique 2 or technique 3 to minimize radiation dose to the lens. (author). 11 refs.; 2 figs.; 3 tabs

  15. A Tribute to Len Barton

    Science.gov (United States)

    Tomlinson, Sally

    2010-01-01

    This article constitutes a short personal tribute to Len Barton in honour of his work and our collegial relationship going back over 30 years. It covers how Len saw his intellectual project of providing critical sociological and political perspectives on special education, disability and inclusion, and his own radical political perspectives. Len's…

  16. Thermal study of bare tips with various system parameters and incision sizes.

    Science.gov (United States)

    Osher, Robert H; Injev, Valentine P

    2006-05-01

    To identify major and minor surgeon-controlled parameters that affect incision temperature when performing microincision lens removal using the Alcon Infiniti Vision System. In vitro research and development laboratory, Alcon Research, Irvine, California, USA. Phacoemulsification was performed in eye-bank cadaver eyes and the following parameters evaluated: incision, duty cycle, ultrasound (US) power, aspiration flow rate (AFR), vacuum, pulse, bottle height and balanced salt solution temperature, and tip design/size. Each parameter was varied while the others remained constant. The resulting temperature of the incision and US tip was measured using a thermal camera. Major contributors to elevated incision temperature included incision size, US power, duty cycle, AFR, vacuum setting, tip design, and presence of an ophthalmic viscosurgical device (OVD). Minor contributors included pulse frequency, bottle height, and temperature of the infusate. Microincision lens removal can be performed at safe temperatures with the knowledgeable selection of surgeon-controlled parameters.

  17. Fluid dynamics, cavitation, and tip-to-tissue interaction of longitudinal and torsional ultrasound modes during phacoemulsification.

    Science.gov (United States)

    Zacharias, Jaime; Ohl, Claus-Dieter

    2013-04-01

    To describe the fluidic events that occur in a test chamber during phacoemulsification with longitudinal and torsional ultrasound (US) modalities. Pasteur Ophthalmic Clinic Phacodynamics Laboratory, Santiago, Chile, and Nanyang Technological University, Singapore. Experimental study. Ultra-high-speed videos of a phacoemulsifying tip were recorded while the tip operated in longitudinal and torsional US modalities using variable US power. Two high-speed video cameras were used to record videos up to 625,000 frames per second. A high-intensity spotlight source was used for illumination to engage shadowgraphy techniques. Particle image velocimetry was used to evaluate fluidic patterns while a hyperbaric environmental system allowed the evaluation of cavitation effects. Tip-to-tissue interaction at high speed was evaluated using human cataract fragments. Particle imaging velocimetry showed the following flow patterns for longitudinal and torsional modes at high US powers: forward-directed streaming with longitudinal mode and backward-directed streaming with torsional mode. The ultrasound power threshold for the appearance of cavitation was 60% for longitudinal mode and 80% for torsional mode. Cavitation was suppressed with pressure of 1.0 bar for longitudinal mode and 0.3 bar for torsional mode. Generation of previously unseen stable gaseous microbubbles was noted. Tip-to-tissue interaction analysis showed the presence of cavitation bubbles close to the site of fragmentation with no apparent effect on cutting. High-speed imaging and particle image velocimetry yielded a better understanding and differentiated the fluidic pattern behavior between longitudinal and torsional US during phacoemulsification. These recordings also showed more detailed aspects of cavitation that clarified its role in lens material cutting for both modalities. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  19. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  20. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  1. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  3. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into ...

  5. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  6. z calibration of the atomic force microscope by means of a pyramidal tip

    DEFF Research Database (Denmark)

    Jensen, Flemming

    1993-01-01

    A new method for imaging the probe tip of an atomic force microscope cantilever by the atomic force microscope itself (self-imaging) is presented. The self-imaging is accomplished by scanning the probe tip across a sharper tip on the surface. By using a pyramidal probe tip with a very well......-defined aspect ratio, this technique provides an excellent z-calibration standard for the atomic force microscope....

  7. AERODYNAMICS OF WING TIP SAILS

    Directory of Open Access Journals (Sweden)

    MUSHTAK AL-ATABI

    2006-06-01

    Full Text Available Observers have always been fascinated by soaring birds. An interesting feature of these birds is the existence of few feathers extending from the tip of the wing. In this paper, small lifting surfaces were fitted to the tip of a NACA0012 wing in a fashion similar to that of wing tip feathers. Experimental measurements of induced drag, longitudinal static stability and trailing vortex structure were obtained.The tests showed that adding wing tip surfaces (sails decreased the induced drag factor and increased the longitudinal static stability. Results identified two discrete appositely rotated tip vortices and showed the ability of wing tip surfaces to break them down and to diffuse them.

  8. Oxygen transport through soft contact lens and cornea: Lens characterization and metabolic modeling

    Science.gov (United States)

    Chhabra, Mahendra

    The human cornea requires oxygen to sustain metabolic processes critical for its normal functioning. Any restriction to corneal oxygen supply from the external environment (e.g., by wearing a low oxygen-permeability contact lens) can lead to hypoxia, which may cause corneal edema (swelling), limbal hyperemia, neovascularization, and corneal acidosis. The need for adequate oxygen to the cornea is a major driving force for research and development of hypertransmissible soft contact lenses (SCLs). Currently, there is no standard technique for measuring oxygen permeability (Dk) of hypertransmissible silicone-hydrogel SCLs. In this work, an electrochemistry-based polarographic apparatus was designed, built, and operated to measure oxygen permeability in hypertransmissible SCLs. Unlike conventional methods where a range of lens thickness is needed for determining oxygen permeabilities of SCLs, this apparatus requires only a single lens thickness. The single-lens permeameter provides a reliable, efficient, and economic tool for measuring oxygen permeabilities of commercial hypertransmissible SCLs. The single-lens permeameter measures not only the product Dk, but, following modification, it measures separately diffusivity, D, and solubility, k, of oxygen in hypertransmissible SCLs. These properties are critical for designing better lens materials that ensure sufficient oxygen supply to the cornea. Metabolism of oxygen in the cornea is influenced by contact-lens-induced hypoxia, diseases such as diabetes, surgery, and drug treatment, Thus, estimation of the in-vivo corneal oxygen consumption rate is essential for gauging adequate oxygen supply to the cornea. Therefore, we have developed an unsteady-state reactive-diffusion model for the cornea-contact-lens system to determine in-vivo human corneal oxygen-consumption rate. Finally, a metabolic model was developed to determine the relation between contact-lens oxygen transmissibility (Dk/L) and corneal oxygen deficiency. A

  9. Evolutionary algorithm for optimization of nonimaging Fresnel lens geometry.

    Science.gov (United States)

    Yamada, N; Nishikawa, T

    2010-06-21

    In this study, an evolutionary algorithm (EA), which consists of genetic and immune algorithms, is introduced to design the optical geometry of a nonimaging Fresnel lens; this lens generates the uniform flux concentration required for a photovoltaic cell. Herein, a design procedure that incorporates a ray-tracing technique in the EA is described, and the validity of the design is demonstrated. The results show that the EA automatically generated a unique geometry of the Fresnel lens; the use of this geometry resulted in better uniform flux concentration with high optical efficiency.

  10. Final Technical Report: Electrohydrodynamic Tip Streaming

    Energy Technology Data Exchange (ETDEWEB)

    Basaran, Osman [Purdue Univ., West Lafayette, IN (United States)

    2016-01-06

    When subjected to strong electric fields, liquid drops and films form conical tips and emit thin jets from their tips. Such electrodydrodynamic (EDH) tip streaming or cone-jetting phenomena, which are sometimes referred to as electrospraying, occur widely in nature, e.g., in ejection of streams of small charged drops from pointed tips of raindrops in thunderclouds, and technology, e.g., in electrospray mass spectrometry or electric field-driven solvent extraction. More recently, EHD cone-jetting has emerged as a powerful technique for direct printing of solar cells, micro- and nano- particle production, and microencapsulation for controlled release. In many of the aforementioned situations, of equal importance to the processes by which one drop disintegrates to form several drops are those by which (a) two drops come together and coalesce and (b) two drops are coupled to form a double droplet system (DDS) or a capillary switch (CS). the main objective of this research program is to advance through simulation, theory, and experiment the breakup, coalescence, and oscillatory dynamics of single and pairs of charged as well as uncharged drops.

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers ... Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de ...

  12. Tips for Starting Physical Activity

    Science.gov (United States)

    ... Legislative Information Advisory & Coordinating Committees Strategic Plans & Reports Research Areas FAQs ... Starting Physical Activity Related Topics Section Navigation Tips to Help You Get Active ...

  13. Surgical treatment of hereditary lens subluxations.

    Science.gov (United States)

    Ozdek, Sengul; Sari, Ayca; Bilgihan, Kamil; Akata, Fikret; Hasanreisoglu, Berati

    2002-01-01

    To evaluate the effectiveness and results of pars plana vitreolensectomy approach with transscleral fixation of intraocular lens in hereditary lens subluxations. Fifteen eyes of 9 consecutive patients with a mean age of 12.8+/-6.2 years (6-26 years) with hereditary lens subluxation were operated on and the results were evaluated in a prospective study. Surgery was considered if best spectacle corrected visual acuity (BSCVA) was less than 20/70. All eyes underwent a 2-port pars plana vitreolensectomy and transscleral fixation of an intraocular lens (IOL). The mean follow-up period was 12.6+/-7.5 months (6-22 months). There was no major intraoperative complication. Preoperatively, 8 eyes (53.3%) had a BSCVA of counting fingers (CF) and 7 eyes (46.6%) had a BSCVA of 20/200 to 20/70. Postoperatively, 14 eyes (93.3%) had a BSCVA of 20/50 or better. None of the patients had IOL decentration or intraocular pressure (IOP) increase during the follow-up period. There was a macular hole formation in 1 eye postoperatively. The early results of pars plana vitreolensectomy with IOL implantation using scleral fixation technique had shown that it not only promises a rapid visual rehabilitation but it is also a relatively safe method. More serious complications, however, may occur in the long term.

  14. Detector LENS as a new tool for solar neutrino spectroscopy

    International Nuclear Information System (INIS)

    Kornoukhov, V.N.

    2001-01-01

    LENS detector is a low-threshold, electron-flavor specific detector for real time measurement of the solar neutrino spectrum at low energies. It is expected that 20 tons of Yb used as a neutrino target should give several hundred events per year. The basic method for implementation of the LENS detector is scintillator technique, namely a liquid scintillator doped (up to 10% in mass) with natural Yb

  15. Phacoemulsification using iris hooks and scleral fixation of the intraocular lens in patients with secondary glaucoma associated with lens subluxation.

    Science.gov (United States)

    Ma, K T; Lee, H K; Seong, G J; Kim, C Y

    2008-09-01

    We described the techniques and results of phacoemulsification using iris hook and scleral fixation of intraocular lens (IOL) in patients with secondary glaucoma associated with lens subluxation. Eight eyes of seven patients with secondary glaucoma associated with lens dislocation, who had undergone the surgery, were retrospectively reviewed. At a mean of 23.5 months+/-13.6 (SD) after the surgery, the mean best-corrected visual acuity improved from 0.24+/-0.21 to 0.83+/-0.3, and mean intraocular pressure (IOP) was changed from 38.4+/-11.4 to 15.5+/-1.8 mmHg at the final examination. There were no vitreoretinal complications except cystoid macular oedema in one eye. The technique appears to be safe and effective in terms of visual rehabilitation and controlling IOP in patients with secondary glaucoma associated with lens subluxation.

  16. A Correlation of Thin Lens Approximation to Thick Lens Design by Using Coddington Factors in Lens Design and Manufacturing

    OpenAIRE

    FARSAKOĞLU, Ö. Faruk

    2014-01-01

    The effect of Coddington factors on aberration functions has been analysed using thin lens approximation. Minimizing spherical aberrations of singlet lenses using Coddington factors in lens design depending on lens manufacturing is discussed. Notation of lens test plate pairs used in lens manufacturing is also presented in terms of Coddington shape factors.

  17. Dark secrets behind the shimmer of contact lens: the Indian scenario

    Directory of Open Access Journals (Sweden)

    Singh Deepak

    2009-05-01

    Full Text Available Abstract Background We studied the bacteriological profile of soft contact lens and its accessories among the asymptomatic subjects and monitored the compliance level with the lens use and its cleaning protocol. Findings A total of 115 (104 daily wear and 11 extended wear subjects using contact lens were studied. Data regarding the duration of use and frequency and method of cleaning were recorded. Contact lens, lens cases, preserving solutions and tips of solution bottles were the samples collected. The isolates were identified on the basis of their phenotypic characters. Samples from 24 subjects (21 daily wear and 3 extended wear were found contaminated. Of the 24 contaminated cases, 23 showed medium adherence to the cleaning protocol. Contamination rate was higher among the 56 daily wear lens users who used same lens for 2 years and more, than the 48 users who used their lenses for less than 2 years. Lens case contamination was found in all the 24 cases. The bacteria isolated were Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus epidermidis and Streptococcus pneumoniae. In extended wear lens users, there was no change in microbial flora on repeating the cultures on day 7 and 14. Conclusion Non-compliance with contact lens use may lead to invitation of microbial flora. The accumulation of these bacteria may act as a precursor to biofilm formation, thus colonizing the lens accessories as well. The bacteria isolated in this study were similar to the ones causing microbial keratitis thus, predisposing the otherwise asymptomatic subjects to permanent visual damage.

  18. Tips for Good Electronic Presentations.

    Science.gov (United States)

    Strasser, Dennis

    1996-01-01

    Describes library uses of presentation graphics software and offers tips for creating electronic presentations. Tips include: audience retention; visual aid options; software package options; presentation planning; presentation showing; and use of text, colors, and graphics. Sidebars note common presentation errors and popular presentation…

  19. Regular Scanning Tunneling Microscope Tips can be Intrinsically Chiral

    International Nuclear Information System (INIS)

    Tierney, Heather L.; Murphy, Colin J.; Sykes, E. Charles H.

    2011-01-01

    We report our discovery that regular scanning tunneling microscope tips can themselves be chiral. This chirality leads to differences in electron tunneling efficiencies through left- and right-handed molecules, and, when using the tip to electrically excite molecular rotation, large differences in rotation rate were observed which correlated with molecular chirality. As scanning tunneling microscopy is a widely used technique, this result may have unforeseen consequences for the measurement of asymmetric surface phenomena in a variety of important fields.

  20. Regular scanning tunneling microscope tips can be intrinsically chiral.

    Science.gov (United States)

    Tierney, Heather L; Murphy, Colin J; Sykes, E Charles H

    2011-01-07

    We report our discovery that regular scanning tunneling microscope tips can themselves be chiral. This chirality leads to differences in electron tunneling efficiencies through left- and right-handed molecules, and, when using the tip to electrically excite molecular rotation, large differences in rotation rate were observed which correlated with molecular chirality. As scanning tunneling microscopy is a widely used technique, this result may have unforeseen consequences for the measurement of asymmetric surface phenomena in a variety of important fields.

  1. Aero-acoustics noise assessment for Wind-Lens turbine

    International Nuclear Information System (INIS)

    Hashem, I.; Mohamed, M.H.; Hafiz, A.A.

    2017-01-01

    This paper introduces an aero-acoustic computational study that investigates the noise caused by one of the most promising wind energy conversion concepts, namely the 'Wind-Lens' technology. The hybrid method - where the flow field and acoustic field are solved separately, was deemed to be an appropriate tool to compute this study. The need to investigate this phenomenon increased gradually, since the feasibility of utilizing Wind-Lens turbine within densely populated cities and urban areas depends largely on their noise generation. Ffowcs Williams-Hawkings (FW-H) equation and its integral solution are used to predict the noise radiating to the farfield. CFD Simulations of transient three-dimensional flow field using (URANS) unsteady Reynolds-averaged Navier-Stokes equations are computed to acquire the acoustic sources location and sound intensity. Then, the noise propagates from the before-mentioned sources to pre-defined virtual microphones positioned in different locations. ANSYS-FLUENT is used to calculate the flow field on and around such turbines which is required for the FW-H code. Some effective parameters are investigated such as Wind-Lens shape, brim height and tip speed ratio. Comparison of the noise emitted from the bare wind turbine and different types of Wind-Lens turbine reveals that, the Wind-Lens generates higher noise intensity. - Highlights: • Aero-acoustic noise generated by wind turbines are one of the major challenges. • Noise from wind turbine equipped with a brimmed diffuser is investigated. • A computational aero-acoustic study using the hybrid method is introduced. • Effective parameters are studied such Wind-Lens shape, brim height and speed ratio. • The optimal shape has a moderate power coefficient and the less noise generation.

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  3. Intracapsular lens extraction for the treatment of pupillary block glaucoma associated with anterior subluxation of the crystalline lens.

    Science.gov (United States)

    Kim, Yong Joon; Ha, Seung Joo

    2013-01-01

    To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.

  4. Optical fiber plasmonic lens for near-field focusing fabricated through focused ion beam

    Science.gov (United States)

    Sloyan, Karen; Melkonyan, Henrik; Moreira, Paulo; Dahlem, Marcus S.

    2017-02-01

    We report on numerical simulations and fabrication of an optical fiber plasmonic lens for near-field focusing applications. The plasmonic lens consists of an Archimedean spiral structure etched through a 100 nm-thick Au layer on the tip of a single-mode SM600 optical fiber operating at a wavelength of 632:8 nm. Three-dimensional finite-difference time-domain computations show that the relative electric field intensity of the focused spot increases 2:1 times when the number of turns increases from 2 to 12. Furthermore, a reduction of the intensity is observed when the initial inner radius is increased. The optimized plasmonic lens focuses light into a spot with a full-width at half-maximum of 182 nm, beyond the diffraction limit. The lens was fabricated by focused ion beam milling, with a 200nm slit width.

  5. Fabrication and Performance of a Lithium X-Ray Lens

    Science.gov (United States)

    Young, Kristina; Khounsary, Ali; Jansen, Andrew N.; Dufresne, Eric M.; Nash, Philip

    2007-01-01

    Compound refractive lenses (CRLs) are arrays of concave lenses whose simple design and ease in implementation and alignment make them an attractive optic to focus x-rays. Factors considered in designing CRLs include lens material, fabrication, and assembly. Lithium is a desirable material because it provides the largest index of refraction decrement per unit absorption length of any solid elements. Lithium is a difficult material to handle and fabricate because it is rather malleable and more importantly, it reacts with moisture, and to a lesser extent, with oxygen and nitrogen in air. It also tends to adhere to molds and dies. We report on the fabrication and performance of a parabolic lithium lens consisting of 32 lenslets. Lenslets are fabricated in a precision press using an indenter with a parabolic profile and a 100 μm tip radius. The indenter is made of stainless steel and is figured using a computer numerically controlled (CNC) machine. The lens is designed to have a 1.7 m focal length at 10 keV energy. In an experiment conducted at the Advanced Photon Source (APS), a 0.5 mm × 0.5 mm monochromatic undulator beam strikes the lens. A focal length of 1.71, a focal spot size of 24 μm × 34 μm, and a peak intensity gain of over 18 are obtained.

  6. Fabrication and Performance of a Lithium X-Ray Lens

    International Nuclear Information System (INIS)

    Young, Kristina; Khounsary, Ali; Jansen, Andrew N.; Dufresne, Eric M.; Nash, Philip

    2007-01-01

    Compound refractive lenses (CRLs) are arrays of concave lenses whose simple design and ease in implementation and alignment make them an attractive optic to focus x-rays. Factors considered in designing CRLs include lens material, fabrication, and assembly. Lithium is a desirable material because it provides the largest index of refraction decrement per unit absorption length of any solid elements. Lithium is a difficult material to handle and fabricate because it is rather malleable and more importantly, it reacts with moisture, and to a lesser extent, with oxygen and nitrogen in air. It also tends to adhere to molds and dies.We report on the fabrication and performance of a parabolic lithium lens consisting of 32 lenslets. Lenslets are fabricated in a precision press using an indenter with a parabolic profile and a 100 μm tip radius. The indenter is made of stainless steel and is figured using a computer numerically controlled (CNC) machine. The lens is designed to have a 1.7 m focal length at 10 keV energy. In an experiment conducted at the Advanced Photon Source (APS), a 0.5 mm x 0.5 mm monochromatic undulator beam strikes the lens. A focal length of 1.71, a focal spot size of 24 μm x 34 μm, and a peak intensity gain of over 18 are obtained

  7. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  8. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. [Seoul National University Hospital (Korea, Republic of)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  9. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  10. TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

    International Nuclear Information System (INIS)

    Park, J.

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  11. At the Tipping Point

    Energy Technology Data Exchange (ETDEWEB)

    Wiley, H. S.

    2011-02-28

    There comes a time in every field of science when things suddenly change. While it might not be immediately apparent that things are different, a tipping point has occurred. Biology is now at such a point. The reason is the introduction of high-throughput genomics-based technologies. I am not talking about the consequences of the sequencing of the human genome (and every other genome within reach). The change is due to new technologies that generate an enormous amount of data about the molecular composition of cells. These include proteomics, transcriptional profiling by sequencing, and the ability to globally measure microRNAs and post-translational modifications of proteins. These mountains of digital data can be mapped to a common frame of reference: the organism’s genome. With the new high-throughput technologies, we can generate tens of thousands of data points from each sample. Data are now measured in terabytes and the time necessary to analyze data can now require years. Obviously, we can’t wait to interpret the data fully before the next experiment. In fact, we might never be able to even look at all of it, much less understand it. This volume of data requires sophisticated computational and statistical methods for its analysis and is forcing biologists to approach data interpretation as a collaborative venture.

  12. Tipping the scales.

    Science.gov (United States)

    1998-12-01

    In the US, the October 1998 murder of a physician who performed abortions was an outward manifestation of the insidious battle against legal abortion being waged by radical Christian social conservatives seeking to transform the US democracy into a theocracy. This movement has been documented in a publication entitled, "Tipping the Scales: The Christian Right's Legal Crusade Against Choice" produced as a result of a 4-year investigation conducted by The Center for Reproductive Law and Policy. This publication describes how these fundamentalists have used sophisticated legal, lobbying, and communication strategies to further their goals of challenging the separation of church and state, opposing family planning and sexuality education that is not based solely on abstinence, promoting school prayer, and restricting homosexual rights. The movement has resulted in the introduction of more than 300 anti-abortion bills in states, 50 of which have passed in 23 states. Most Christian fundamentalist groups provide free legal representation to abortion clinic terrorists, and some groups solicit women to bring specious malpractice claims against providers. Sophisticated legal tactics are used by these groups to remove the taint of extremism and mask the danger posed to US constitutional principles being posed by "a well-financed and zealous brand of radical lawyers and their supporters."

  13. Magnifying lens for 800 MeV proton radiography

    International Nuclear Information System (INIS)

    Merrill, F. E.; Campos, E.; Espinoza, C.; Hogan, G.; Hollander, B.; Lopez, J.; Mariam, F. G.; Morley, D.; Morris, C. L.; Murray, M.; Saunders, A.; Schwartz, C.; Thompson, T. N.

    2011-01-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  14. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    Science.gov (United States)

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  15. Characteristics of the thick, compound refractive lens

    International Nuclear Information System (INIS)

    Pantell, Richard H.; Feinstein, Joseph; Beguiristain, H. Raul; Piestrup, Melvin A.; Gary, Charles K.; Cremer, Jay T.

    2003-01-01

    A compound refractive lens (CRL), consisting of a series of N closely spaced lens elements each of which contributes a small fraction of the total focusing, can be used to focus x rays or neutrons. The thickness of a CRL can be comparable to its focal length, whereupon a thick-lens analysis must be performed. In contrast with the conventional optical lens, where the ray inside the lens follows a straight line, the ray inside the CRL is continually changing direction because of the multiple refracting surfaces. Thus the matrix representation for the thick CRL is quite different from that for the thick optical lens. Principal planes can be defined such that the thick-lens matrix can be converted to that of a thin lens. For a thick lens the focal length is greater than for a thin lens with the same lens curvature, but this lengthening effect is less for the CRL than for the conventional optical lens

  16. Electrically switchable holographic liquid crystal/polymer Fresnel lens using a Michelson interferometer.

    Science.gov (United States)

    Jashnsaz, Hossein; Mohajerani, Ezeddin; Nemati, Hossein; Razavi, Seyed Hossein; Alidokht, Isa Ahmad

    2011-06-10

    A holographic technique for fabricating an electrically switchable liquid crystal/polymer composite Fresnel lens is reported. A Michelson interferometer is used to produce the required Fresnel pattern, by placing a convex lens into one path of the interferometer. Simplicity of the method and the possibility of fabricating different focal length lenses in a single arrangement are advantages of the method. The performance of the fabricated lens was demonstrated and its electro-optical properties were investigated for its primary focal length.

  17. Rapid tryptic mapping using enzymatically active mass spectrometer probe tips

    Energy Technology Data Exchange (ETDEWEB)

    Dogruel, D.; Williams, P.; Nelson, R.W. [Arizona State Univ., Tempe, AZ (United States)

    1995-12-01

    A method has been developed for rapid, sensitive, and accurate tryptic mapping of polypeptides using matrix-assisted laser desorption/ionization time-of-flight mass analysis. The technique utilizes mass spectrometer probe tips which have been activated through the covalent immobilization of trypsin. The enzymatically active probe tips were used for the tryptic mapping of chicken egg lysozyme and the results compared with those obtained using either free trypsin or agarose-immobilized trypsin. A significant increase in the overall sensitivity of the process was observed using the active probe tips, as well as the production of more characteristic proteolytic fragments and the elimination of background signals due to the autolysis of the trypsin. Further, probe tip digestions were found to be rapid and convenient. 19 refs., 6 figs., 2 tabs.

  18. Sharp tipped plastic hollow microneedle array by microinjection moulding

    Science.gov (United States)

    Yung, K. L.; Xu, Yan; Kang, Chunlei; Liu, H.; Tam, K. F.; Ko, S. M.; Kwan, F. Y.; Lee, Thomas M. H.

    2012-01-01

    A method of producing sharp tipped plastic hollow microneedle arrays using microinjection moulding is presented in this paper. Unlike traditional approaches, three mould inserts were used to create the sharp tips of the microneedles. Mould inserts with low surface roughness were fabricated using a picosecond laser machine. Sharp tipped plastic hollow microneedles 500 µm in height were fabricated using a microinjection moulding machine developed by the authors’ group. In addition, the strength of the microneedle was studied by simulation and penetration experiments. Results show that the microneedles can penetrate into skin, delivering liquid successfully without any breakage or severe deformation. Techniques presented in this paper can be used to fabricate sharp tipped plastic hollow microneedle arrays massively with low cost.

  19. Sharp tipped plastic hollow microneedle array by microinjection moulding

    International Nuclear Information System (INIS)

    Yung, K L; Xu, Yan; Kang, Chunlei; Liu, H; Tam, K F; Ko, S M; Kwan, F Y; Lee, Thomas M H

    2012-01-01

    A method of producing sharp tipped plastic hollow microneedle arrays using microinjection moulding is presented in this paper. Unlike traditional approaches, three mould inserts were used to create the sharp tips of the microneedles. Mould inserts with low surface roughness were fabricated using a picosecond laser machine. Sharp tipped plastic hollow microneedles 500 µm in height were fabricated using a microinjection moulding machine developed by the authors’ group. In addition, the strength of the microneedle was studied by simulation and penetration experiments. Results show that the microneedles can penetrate into skin, delivering liquid successfully without any breakage or severe deformation. Techniques presented in this paper can be used to fabricate sharp tipped plastic hollow microneedle arrays massively with low cost. (paper)

  20. Tips for Daily Living

    Science.gov (United States)

    ... Simple Techniques Can Help Memory after a Stroke Self-Esteem after Stroke Cognitive Challenges After Stroke Depression Trumps ... Living Driving Finding Support You Are Not Alone Online Support Recovery and Support after Stroke Stroke Family ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... bleeding resistant to traditional medical treatments. The greatest difference in performing TIPS in children is their tremendous ...

  2. Fitness: Tips for Staying Motivated

    Science.gov (United States)

    Healthy Lifestyle Fitness Fitness is for life. Motivate yourself with these practical tips. By Mayo Clinic Staff Have ... 27, 2015 Original article: http://www.mayoclinic.org/healthy-lifestyle/fitness/in-depth/fitness/art-20047624 . Mayo Clinic ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... deeply you are sedated. When the needle is advanced through the liver and the pathway is expanded ... are the limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... to determine the severity of the condition. To help plan for the placement of the TIPS stent, ... Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients with ... stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding and the accumulation of fluid in the chest ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in the chest or abdomen. This condition is most commonly seen in adults, often as a result ... minimally invasive procedures such as a TIPS are most often performed by a specially trained interventional radiologist ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... open. Patients who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal ... problems leading to cirrhosis (scarring of the liver). Portal hypertension can also occur in children, although children are ...

  8. Energy Savers: Cool Summer Tips

    International Nuclear Information System (INIS)

    Miller, M.

    2001-01-01

    A tri-fold brochure addressing energy-saving tips for homeowners ranging from low- or no-cost suggestions to higher cost suggestions for longer-term savings. Cooling, windows, weatherizing, and landscaping are addressed

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... complex and lengthy procedures requiring extended fluoroscopy use) death (rare) top of page What are the limitations ... filtered out by the liver. The TIPS may cause too much of these substances to bypass the ...

  10. Girlfriends' Health and Safety Tips

    Science.gov (United States)

    ... in Women? Women's Safety and Health Issues at Work Health Equity Girlfriends' Health and Safety Tips Recommend on Facebook Tweet Share Compartir Having friends is an important part of life. Celebrate female friendship and support your girlfriends by ...

  11. Search Tips: MedlinePlus

    Science.gov (United States)

    ... of this page: https://medlineplus.gov/searchtips.html Search Tips To use the sharing features on this page, please enable JavaScript. How do I search MedlinePlus? The search box appears at the top ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. You ... with ascites or variceal bleeding resistant to traditional medical treatments. The greatest difference in performing TIPS in ...

  13. Computerized automatic tip scanning operation

    International Nuclear Information System (INIS)

    Nishikawa, K.; Fukushima, T.; Nakai, H.; Yanagisawa, A.

    1984-01-01

    In BWR nuclear power stations the Traversing Incore Probe (TIP) system is one of the most important components in reactor monitoring and control. In previous TIP systems, however, operators have suffered from the complexity of operation and long operation time required. The system presented in this paper realizes the automatic operation of the TIP system by monitoring and driving it with a process computer. This system significantly reduces the burden on customer operators and improves plant efficiency by simplifying the operating procedure, augmenting the accuracy of the measured data, and shortening operating time. The process computer is one of the PODIA (Plant Operation by Displayed Information Automation) systems. This computer transfers control signals to the TIP control panel, which in turn drives equipment by microprocessor control. The process computer contains such components as the CRT/KB unit, the printer plotter, the hard copier, and the message typers required for efficient man-machine communications. Its operation and interface properties are described

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... surgery. Your TIPS should have less of an effect than open surgical bypass on future liver transplantation ... Encephalopathy can be treated with certain medications, a special diet or, by revising the stent, but sometimes ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ... limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening liver failure ...

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... is completed. top of page What are the benefits vs. risks? Benefits A TIPS is designed to produce the same ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... hepatic vein to identify the portal venous system. Access is then gained from the hepatic vein into ... TIPS procedure to make sure that it remains open and functions properly. top of page Who interprets ...

  20. Tips to Prevent Mosquito Bites

    Science.gov (United States)

    ... discourage mosquitoes, ticks and other biting insects from landing on you. Here are tips for other preventive ... CDC Mosquito Control Methods - NPIC Exit Top of Page Contact Us to ask a question, provide feedback, ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients ... site. Using ultrasound, the doctor will identify your internal jugular vein , which is situated above your collarbone, ...

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and medical diseases. This can result in significant challenges in creating the TIPS. top of page Additional ... Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This ... here Images × Image Gallery Radiologist and patient consultation. View full size with caption Pediatric Content Some imaging ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... observed. This procedure is usually completed in an hour or two but may take up to several ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the portal system using a TIPS needle (a special long needle extending from the neck into the ... Encephalopathy can be treated with certain medications, a special diet or, by revising the stent, but sometimes ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Intrahepatic Portosystemic Shunt (TIPS)? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... of bleeding that can occur can sometimes be life threatening and those patients are monitored in intensive ...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... blood draining from the bowel back to the heart while avoiding the liver. TIPS may successfully reduce ... blood away from the liver back to the heart). A stent is then placed in this tunnel ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... portal vein to the hepatic vein in the liver. A small metal device called a stent is ... bowel back to the heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver. A small metal device called a stent is placed to keep the connection open and ... a small, tubular metal device commonly called a stent . During a TIPS procedure, interventional radiologists use image ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal vein ... the local anesthetic is injected. Most of the sensation is at the skin incision site, which is ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... physician will numb an area just above your right collarbone with a local anesthetic . A very small ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits A TIPS is designed to produce the ... skin that does not have to be stitched. Risks Any procedure where the skin is penetrated carries ...

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Patients who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal ... leading to cirrhosis (scarring of the liver). Portal hypertension can also occur in children, although children are ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... above your collarbone, and guide a catheter, a long, thin, hollow plastic tube into the vessel. Using ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... This can result in significant challenges in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ...

  1. Effects of cloning and root-tip size on observations of fungal ITS sequences from Picea glauca roots

    Science.gov (United States)

    Daniel L. Lindner; Mark T. Banik

    2009-01-01

    To better understand the effects of cloning on observations of fungal ITS sequences from Picea glauca (white spruce) roots two techniques were compared: (i) direct sequencing of fungal ITS regions from individual root tips without cloning and (ii) cloning and sequencing of fungal ITS regions from individual root tips. Effect of root tip size was...

  2. Tip model of cold fission

    International Nuclear Information System (INIS)

    Goennenwein, F.; Boersig, B.

    1991-01-01

    Cold fission is defined to be the limiting case of nuclear fission where virtually all of the available energy is converted into the total kinetic energy of the fragments. The fragments have, therefore, to be born in or at least close to their respective ground states. Starting from the viewpoint that cold fission corresponds to most compact scission configurations, energy constraints have been exploited to calculate minimum tip distances between the two nascent fragments in binary fission. Crucial input parameters to this tip model of cold fission are the ground-state deformations of fragment nuclei. It is shown that the minimum tip distances being compatible with energy conservation vary strongly with both the mass and charge fragmentation of the fission prone nucleus. The tip distances refer to nuclei with equivalent sharp surfaces. In keeping with the size of the surface width of leptodermous nuclei, only configurations where the tip distances are smaller than a few fm may be considered as valid scission configurations. From a comparison with experimental data on cold fission this critical tip distance appears to be 3.0 fm for the model parameters chosen. Whenever the model calculation yields tip distances being smaller than the critical value, a necessary condition for attaining cold fission is considered to be fulfilled. It is shown that this criterion allows to understand in fair agreement with experiment which mass fragmentations are susceptible to lead to cold fission and which fragment-charge divisions are the most favored in each isobaric mass chain. Being based merely on energy arguments, the model cannot aim at predicting fragment yields in cold fission. However, the tip model proposed appears well suited to delineate the phase space where cold fission phenomena may come into sight. (orig.)

  3. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  4. Wedged multilayer Laue lens

    International Nuclear Information System (INIS)

    Conley, Ray; Liu Chian; Qian Jun; Kewish, Cameron M.; Macrander, Albert T.; Yan Hanfei; Maser, Joerg; Kang, Hyon Chol; Stephenson, G. Brian

    2008-01-01

    A multilayer Laue lens (MLL) is an x-ray focusing optic fabricated from a multilayer structure consisting of thousands of layers of two different materials produced by thin-film deposition. The sequence of layer thicknesses is controlled to satisfy the Fresnel zone plate law and the multilayer is sectioned to form the optic. An improved MLL geometry can be created by growing each layer with an in-plane thickness gradient to form a wedge, so that every interface makes the correct angle with the incident beam for symmetric Bragg diffraction. The ultimate hard x-ray focusing performance of a wedged MLL has been predicted to be significantly better than that of a nonwedged MLL, giving subnanometer resolution with high efficiency. Here, we describe a method to deposit the multilayer structure needed for an ideal wedged MLL and report our initial deposition results to produce these structures

  5. Reversal of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-Induced Hepatic Encephalopathy Using a Strictured Self-Expanding Covered Stent

    International Nuclear Information System (INIS)

    Cox, Mitchell W.; Soltes, George D.; Lin, Peter H.; Bush, Ruth L.; Lumsden, Alan B.

    2003-01-01

    Hepatic encephalopathy is a known complication following percutaneous transjugular intrahepatic portosystemic shunt (TIPS) placement. We describe herein a simple and effective strategy of TIPS revision by creating an intraluminal stricture within a self-expanding covered stent, which is deployed in the portosystemic shunt to reduce the TIPS blood flow. This technique was successful in reversing a TIPS-induced hepatic encephalopathy in our patient

  6. Improved illumination system of laparoscopes using an aspherical lens array.

    Science.gov (United States)

    Wu, Rengmao; Qin, Yi; Hua, Hong

    2016-06-01

    The current fiber-based illumination systems of laparoscopes are unable to uniformly illuminate a large enough area in abdomen due to the limited numerical aperture (NA) of the fiber bundle. Most energy is concentrated in a small region at the center of the illumination area. This limitation becomes problematic in laparoscopes which require capturing a wide field of view. In this paper, we propose an aspherical lens array which is used to direct the outgoing rays from the fiber bundle of laparoscope to produce a more uniformly illuminated, substantially larger field coverage than standalone fiber source. An intensity feedback method is developed to design the aspherical lens unit for extended non-Lambertian sources, which is the key to the design of this lens array. By this method, the lens unit is obtained after only one iteration, and the lens array is constructed by Boolean operation. Then, the ray-tracing technique is used to verify the design. Further, the lens array is fabricated and experimental tests are performed. The results clearly show that the well-illuminated area is increased to about 0.107m(2) from 0.02m(2) (about 5x larger than a standard fiber illumination source). More details of the internal organs can be clearly observed under this improved illumination condition, which also reflects the significant improvement in the optical performance of the laparoscope.

  7. Intraocular lens calculations in atypical eyes

    Directory of Open Access Journals (Sweden)

    Aazim A Siddiqui

    2017-01-01

    Full Text Available Cataract surgery is the most performed surgical procedure in the field of ophthalmology. The process of intraocular lens (IOL calculations is a critical step to achieving successful outcomes. Many IOL formulae exist to guide surgeons through the difficult process of picking the most appropriate lens to achieve a certain target refraction. However, these formulae reach within 0.50 diopters of the target refraction only 75% of the time, leaving 25% of the eyes with a significant refractive surprise. A literature review was performed to investigate all the relevant published material on the history, progress, and recent advancements of IOL calculations. Based on this review, the appropriate history, evolution, progress, limitations, and recent advancements are analyzed and explained. Although the modern IOL formulae and biometric devices perform well for average eyes, they are suboptimal for eyes with atypical biometric parameters and also those that are postrefractive and keratoconic. There has not been a single, perfect formula that can resolve the complexities of this process. Various methods of formula optimization and newer generation of IOL formulae and devices may hold the key to improving outcomes in both typical and atypical eyes. These solutions minimize refractive error by introducing new input parameters and complex mathematical techniques to better estimate postoperative lens position.

  8. Scleral suspension pars-plana lensectomy for ectopia lentis followed by suture fixation of intraocular lens

    Directory of Open Access Journals (Sweden)

    Mitra Sandip

    2001-01-01

    Full Text Available Purpose: To describe a simple technique of scleral suspension-pars plana lensectomy (SS-PPL in acquired and congenital ectopia lentis and scleral fixation of intraocular lens (IOL. Materials and Methods: Twenty eyes of 16 patients (12 unilateral and 4 bilateral cases of "essential familial lens subluxation" aged 10-40 years (mean 25 years underwent SS-PPL with implantation of scleral fixated IOL. Indications for surgery were best-corrected visual acuity <6/18, bisection of pupil by the lens, and lens-induced glaucoma. Prerequisites for SS-PPL were, visibility of part of the lens in the pupillary area and soft lens. Results: Postoperative visual acuity ranged from 6/6 - 6/36. Lens tilt in 3 cases(15% and small decentration in 2 cases(10% were seen; however these did not seriously compromise the visual result. Scant vitreous bleeding on the first postoperative day was seen in 3 cases (15%. Conclusion: The advantages of the scleral suspension of subluxated lens prior to lensectomy include stabilization; it allows proper viewing of the lens, avoids injury to the iris and cliary body during lensectomy and reduces the possibility of dislocation of the lens.

  9. High precision attachment of silver nanoparticles on AFM tips by dielectrophoresis.

    Science.gov (United States)

    Leiterer, Christian; Wünsche, Erik; Singh, Prabha; Albert, Jens; Köhler, Johann M; Deckert, Volker; Fritzsche, Wolfgang

    2016-05-01

    AFM tips are modified with silver nanoparticles using an AC electrical field. The used technique works with sub-micron precision and also does not require chemical modification of the tip. Based on the electrical parameters applied in the process, particle density and particle position on the apex of the tip can be adjusted. The feasibility of the method is proven by subsequent tip-enhanced Raman spectroscopy (TERS) measurements using the fabricated tips as a measurement probe. Since this modification process itself does not require any lithographic processing, the technique can be easily adapted to modify AFM tips with a variety of nanostructures with pre-defined properties, while being parallelizable for a potential commercial application.

  10. Characterization of SCC crack tip and hydrogen distribution in alloy 600

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Katsuhiko; Nakajima, Nobuo; Fukuya, Koji [Institute of Nuclear Safety System Inc., Mihama, Fukui (Japan); Hatano, Yuji [Toyama Univ. (Japan)

    2001-09-01

    In order to identify the mechanism of primary water stress corrosion cracking (SCC), direct observations of SCC crack tip microstructure and hydrogen distribution in alloy 600 were carried out. A new technique has been developed to prepare electron transparent foils including the crack tip using focused-ion beam (FIB) micro-processing technique. Cr-rich oxide and metal-Ni phase were identified in the crack tip and grain boundary ahead of the crack. >From the fact that similar microstructure was observed in the surface oxide layer, it is suggested that the oxidation mechanism is identical at the crack tip region and the surface. It became clear that the crack tip region and the oxidized grain boundary don't work as strong trapping sites of solute hydrogen under unloaded condition, because a homogeneous hydrogen distribution around the crack tip region was detected by tritium microautoradiography. (author)

  11. Assessment of wave propagation on surfaces of crystalline lens with phase sensitive optical coherence tomography

    International Nuclear Information System (INIS)

    Manapuram, R K; Larin, K V; Baranov, S A; Manne, V G R; Mashiatulla, M; Sudheendran, N; Aglyamov, S; Emelianov, S

    2011-01-01

    We propose a real-time technique based on phase-sensitive swept source optical coherence tomography (PhS-SSOCT) modality for noninvasive quantification of very small optical path length changes produced on the surface of a mouse crystalline lens. Propagation of submicron mechanical waves on the surface of the lens was induced by periodic mechanical stimulation. Obtained results demonstrate that the described method is capable of detecting minute damped vibrations with amplitudes as small as 30 nanometers on the lens surface and hence, PhS-SSOCT could be potentially used to assess biomechanical properties of a crystalline lens with high accuracy and sensitivity

  12. Tips for Chronic Pain

    Science.gov (United States)

    ... Don’t let stress compound your pain. • Stress is the result of the way you react to the world, and heightened stress equals heightened pain. Learn relaxation techniques or seek help in reducing your stress level. Get enough sleep. • Practice good sleep habits and get adequate sleep on a ...

  13. Manufacturing PDMS micro lens array using spin coating under a multiphase system

    International Nuclear Information System (INIS)

    Sun, Rongrong; Yang, Hanry; Rock, D Mitchell; Danaei, Roozbeh; Panat, Rahul; Kessler, Michael R; Li, Lei

    2017-01-01

    The development of micro lens arrays has garnered much interest due to increased demand of miniaturized systems. Traditional methods for manufacturing micro lens arrays have several shortcomings. For example, they require expensive facilities and long lead time, and traditional lens materials (i.e. glass) are typically heavy, costly and difficult to manufacture. In this paper, we explore a method for manufacturing a polydimethylsiloxane (PDMS) micro lens array using a simple spin coating technique. The micro lens array, formed under an interfacial tension dominated system, and the influence of material properties and process parameters on the fabricated lens shape are examined. The lenses fabricated using this method show comparable optical properties—including surface finish and image quality—with a reduced cost and manufacturing lead time. (paper)

  14. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p rate, self grading was relatively high. Therefore, these results indicate the need for patient education and encouragement of better lens wearing habits and all of the lens maintenance steps at each patient visit.

  15. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  16. 21 CFR 886.1375 - Bagolini lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bagolini lens. 886.1375 Section 886.1375 Food and... OPHTHALMIC DEVICES Diagnostic Devices § 886.1375 Bagolini lens. (a) Identification. A Bagolini lens is a device that consists of a plane lens containing almost imperceptible striations that do not obscure...

  17. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  18. Immunohistochemical studies of lens crystallins in the dysgenetic lens (dyl) mutant mice

    NARCIS (Netherlands)

    Brahma, S.K.; Sanyal, S.

    1984-01-01

    The lens in the dyl mutant mice shows a persistent lens-ectodermal connection as well as degeneration and extrusion of lens materials after the initial differentiation of the fibres. Immunohistochemical investigation of the ontogeny of the lens crystallins in this developing mutant lens has been

  19. Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations

    International Nuclear Information System (INIS)

    Jaillon, Franck; Zheng Wei; Huang Zhiwei

    2008-01-01

    In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a flat tip excitation fiber associated with a ball lens, discrimination of fluorescence signals generated in different tissue depths is achievable. In comparison with a flat-tip collection fiber, the use of a large bevel angled collection fiber enables a better differentiation between the shallow and deep tissue layers by changing the excitation-collection fiber separations. This work suggests that the beveled fiber-optic probe coupled with a ball lens has the potential to facilitate depth-resolved fluorescence measurements of epithelial tissues

  20. Twelve tips for effective body language for medical educators.

    Science.gov (United States)

    Hale, Andrew J; Freed, Jason; Ricotta, Daniel; Farris, Grace; Smith, C Christopher

    2017-09-01

    A significant proportion of human communication is nonverbal. Although the fields of business and psychology have significant literature on effectively using body language in a variety of situations, there is limited literature on effective body language for medical educators. To provide 12 tips to highlight effective body language strategies and techniques for medical educators. The tips provided are based on our experiences and reflections as clinician-educators and the available literature. The 12 tips presented offer specific strategies to engage learners, balance learner participation, and bring energy and passion to teaching. Medical educators seeking to maximize their effectiveness would benefit from an understanding of how body language affects a learning environment and how body language techniques can be used to engage audiences, maintain attention, control challenging learners, and convey passion for a topic. Understanding and using body language effectively is an important instructional skill.

  1. Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve.

    Directory of Open Access Journals (Sweden)

    Aeri Yoo

    Full Text Available To compare a modified phacoemulsification tip with the established micro tip, in terms of temperature at the corneal wound, efficiency, and chatter events, using the Centurion® Vision system.Eighty porcine eyes were randomized into 4 groups: 1sleeveless conventional 45D MiniFlared ABS® Kelman tip (1.1-mm incision; 2sleeveless new modified 45D ABS® INTREPID® balanced tip(1.1-mm incision; 3 Kelman tip with own sleeve (2.2-mm incision; 4Balanced tip with modified 4-rib sleeve (2.2-mm incision. Measurements were taken with 2 settings: longitudinal(power 40% and 70% and torsional mode (power 40% and 100%. Peak temperatures were measured 0, 10, 30, and 60 seconds after continuous ultrasound power. For the efficiency test, porcine lens nuclei were formalin soaked and cut into 2.0 mm3 cubes. Efficiency and chatter were examined.In all longitudinal settings, the sleeveless groups(1 and 2 showed lower temperatures than the sleeved groups(3 and 4 (P = 0.003. In 100% torsional mode, groups 3 and 4 produced significantly different temperatures(37.13 ± 1.44 and 35.14 ± 0.54, respectively; P = 0.007.The efficiency, in a 100% power torsional setting, was13.52 ± 2.60 sec for group 4, and 44.45± 14.75 sec for group 3 (P<0.001.The two different bare tips show no significant differences in thermogenesis. However, the balanced tip with sleeve produces lower temperaturesat100% torsional power and better efficiency than the Kelman tip.

  2. 3D Inkjet Printed Helical Antenna with Integrated Lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-08-30

    The gain of an antenna can be enhanced through the integration of a lens, although this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, through a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB, which provides a peak gain of about 12.9 dBi at 8.8 GHz. The 3-dB axial ratio (AR) bandwidth of the antenna with the lens is 5.5%. This work also reports the complete characterization of this new process in terms of minimum features sizes and achievable conductivities. Due to monolithic integration of the lens through a fully printed process, this antenna configuration offers high gain performance by using a low cost and rapid fabrication technique. © 2016 IEEE.

  3. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  4. Crystalline lens and refractive development.

    Science.gov (United States)

    Iribarren, Rafael

    2015-07-01

    Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Single lens laser beam shaper

    Science.gov (United States)

    Liu, Chuyu [Newport News, VA; Zhang, Shukui [Yorktown, VA

    2011-10-04

    A single lens bullet-shaped laser beam shaper capable of redistributing an arbitrary beam profile into any desired output profile comprising a unitary lens comprising: a convex front input surface defining a focal point and a flat output portion at the focal point; and b) a cylindrical core portion having a flat input surface coincident with the flat output portion of the first input portion at the focal point and a convex rear output surface remote from the convex front input surface.

  6. Root tips moving through soil

    Science.gov (United States)

    Curlango-Rivera, Gilberto

    2011-01-01

    Root elongation occurs by the generation of new cells from meristematic tissue within the apical 1–2 mm region of root tips. Therefore penetration of the soil environment is carried out by newly synthesized plant tissue, whose cells are inherently vulnerable to invasion by pathogens. This conundrum, on its face, would seem to reflect an intolerable risk to the successful establishment of root systems needed for plant life. Yet root tip regions housing the meristematic tissues repeatedly have been found to be free of microbial infection and colonization. Even when spore germination, chemotaxis, and/or growth of pathogens are stimulated by signals from the root tip, the underlying root tissue can escape invasion. Recent insights into the functions of root border cells, and the regulation of their production by transient exposure to external signals, may shed light on long-standing observations. PMID:21455030

  7. Crack tip stress and strain

    International Nuclear Information System (INIS)

    Francois, D.

    1975-01-01

    The study of potential energy variations in a loaded elastic solid containing a crack leads to determination of the crack driving force G. Generalization of this concept to cases other than linear elasticity leads to definition of the integral J. In a linear solid, the crack tip stress field is characterized by a single parameter: the stress-intensity factor K. When the crack tip plastic zone size is confined to the elastic singularity J=G, it is possible to establish relationship between these parameters and plastic strain (and in particular the crack tip opening displacement delta). The stress increases because of the triaxiality effect. This overload rises with increasing strain hardening. When the plastic zone size expands, using certain hypotheses, delta can be calculated. The plastic strain intensity is exclusively dependent on parameter J [fr

  8. Optical fiber meta-tips

    Science.gov (United States)

    Principe, Maria; Micco, Alberto; Crescitelli, Alessio; Castaldi, Giuseppe; Consales, Marco; Esposito, Emanuela; La Ferrara, Vera; Galdi, Vincenzo; Cusano, Andrea

    2016-04-01

    We report on the first example of a "meta-tip" configuration that integrates a metasurface on the tip of an optical fiber. Our proposed design is based on an inverted-Babinet plasmonic metasurface obtained by patterning (via focused ion beam) a thin gold film deposited on the tip of an optical fiber, so as to realize an array of rectangular aperture nanoantennas with spatially modulated sizes. By properly tuning the resonances of the aperture nanoantennas, abrupt variations can be impressed in the field wavefront and polarization. We fabricated and characterized several proof-of-principle prototypes operating an near-infrared wavelengths, and implementing the beam-steering (with various angles) of the cross-polarized component, as well as the excitation of surface waves. Our results pave the way to the integration of the exceptional field-manipulation capabilities enabled by metasurfaces with the versatility and ubiquity of fiber-optics technological platforms.

  9. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  10. Micro-raman and tip-enhanced raman spectroscopy of carbon allotropes

    NARCIS (Netherlands)

    Hoffmann, G.G.; With, de G.; Loos, J.

    2008-01-01

    Raman spectroscopic data are obtained on various carbon allotropes like diamond, amorphous carbon, graphite, graphene and single wall carbon nanotubes by micro-Raman spectroscopy, tip-enhanced Raman spectroscopy and tip-enhanced Raman spectroscopy imaging, and the potentials of these techniques for

  11. Influence of atomic force microscope tip-sample interaction on the study of scaling behavior

    NARCIS (Netherlands)

    Aue, J.; de Hosson, J.T.M.

    1997-01-01

    Images acquired with atomic force microscopy are based on tip-sample interaction. It is shown that using scanning probe techniques for determining scaling parameters of a surface leads to an underestimate of the actual scaling dimension, due to the dilation of tip and surface. How much we

  12. Peculiarities of lens and tail regeneration detected in newts after spaceflight aboard Foton M3

    Science.gov (United States)

    Grigoryan, Eleonora N.; Almeida, Eduardo; Poplinskaya, Valentina; Novikova, Julia; Domaratskaya, Elena; Aleinikova, Karina; Souza, Kenneth; Skidmore, Mike; Grigoryan, Eleonora N.

    In September 2007 the joint, 12 day long experiment was carried out aboard Russian satellite Foton M3. The goal of the experiment was to study eye lens, tail and forelimb toe regeneration in adult 16 newts (Pl. waltl.) operated 10 days before taking-off. In spaceflight and synchronous ground control we used video recording, temperature and irradiation control, as well as constant availability of thymidine analog BrdU for its absorption via animals' skin. New techniques allowed us to analyze animals' behavior in hyperand microgravity periods of time, to take proper account of spaceflight factors, and measure accumulated pools of DNA-synthesizing cells in regenerating tissues. All tissue specimens obtained from animals were isolated in the day of landing and then prepared for morphological, immunochemical and molecular investigations. Synchronous control was shifted for two days and reproduced flight conditions except changes of gravity influence. As a result in flown animals as compared with synchronous ground control we found lens regeneration of 0.5-1 stage speeded up and an increased BrdU+ (S-phase) cell number in eye cornea, growth zone, limbus and newly forming lens. These features of regeneration were accompanied by an increase of FGF2 expression in eye growth zone and heat shock protein (HSP90) induction purely in retinal macroglial cells of regenerating eyes. Toe regeneration rate was equal and achieved the stage of accomplished healing of amputation area in both groups - "flown" and control animals. We found no essential differences in tail regeneration rate and tail regenerate sizes in the newts exposed to space and on ground. In both groups tail regeneration reached the stage IV-V when tail length and square were around 4.4 mm and 15.5 mm2, correspondingly. However we did observe remarkable changes of tail regenerate form and some of pigmentation. Computer morphometrical analysis showed that only in ground control animals the evident dorso

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of TIPS? ...

  14. Nanobits: customizable scanning probe tips

    DEFF Research Database (Denmark)

    Kumar, Rajendra; Shaik, Hassan Uddin; Sardan Sukas, Özlem

    2009-01-01

    We present here a proof-of-principle study of scanning probe tips defined by planar nanolithography and integrated with AFM probes using nanomanipulation. The so-called 'nanobits' are 2-4 mu m long and 120-150 nm thin flakes of Si3N4 or SiO2, fabricated by electron beam lithography and standard s...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... thin, hollow plastic tube into the vessel. Using real time x-ray guidance, your doctor will then guide ... invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of an effect ...

  16. The tip of the iceberg

    DEFF Research Database (Denmark)

    Bjørst, Lill Rastad

    2010-01-01

      Abstract: The tip of the iceberg: Ice as a nonhuman actor of the climate change debate   The global climate change debate has the Arctic as a core region of concern and ice has become a central aspect of discourses. This article discusses ice representations from six different contexts linked...

  17. Gardening Health and Safety Tips

    Science.gov (United States)

    ... or who take certain medications (i.e. for depression, insomnia, or poor circulation). Eat healthy foods to help keep you energized. Extreme Heat Keep Your Cool in Hot Weather Tips for persons with disabilities and physical activity. Talk to your health care provider if you have physical, mental, or ...

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Portosystemic Shunt (TIPS) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ... of Use | Links | Site Map Copyright © 2018 ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  20. Useful Tips on Avoiding Plagiarism

    Science.gov (United States)

    Hamalainen, Maryellen

    2007-01-01

    Teachers are generally kind and nurturing people. Students who plagiarize their assignments from these kind and nurturing teachers are often given a second chance when caught and encouraged to do their work over, but it would be better to eliminate their need to plagiarize. The first tip for eliminating plagiarism has not so much to do with what…

  1. Assigning Effective Homework. Classroom Tips

    Science.gov (United States)

    American Federation of Teachers (NJ), 2010

    2010-01-01

    Each new school year brings high hopes, great expectations and challenges for both new and seasoned educators. The American Federation of Teachers (AFT) has developed a series called "Classroom Tips" to help educators start the year right and anticipate the year ahead. Over the past 40 years, most research studies on homework have found that…

  2. Establecimiento del cálculo del diámetro de cresta exterior de un engranaje cónico con técnicas de grafos. // Procedure for the calculation of outer tip diameter on straight bevel gear by means of graphs technique.

    Directory of Open Access Journals (Sweden)

    G. González Rey

    2007-09-01

    Full Text Available Mediante un modelo matemático son dadas las principales relaciones entre los parámetros geométricos básicos requeridosen la evaluación del diámetro de cresta exterior de un engranaje ortogonal de ruedas cónicas con dientes rectos y suma decorrecciones radiales iguales a cero. Adicionalmente, serán brindados algunos resultados que asocian la correspondenciaentre una geometría racional y la capacidad de carga de un engranaje cónico con restricciones del diámetro de crestaexterior. Para la determinación de los procedimientos de cálculo, los problemas planteados sobre los modelos matemáticoshan sido serán representados por medio de grafos bicromáticos.Palabras claves: Engranajes cónicos, diseño racional, modelo matemático._______________________________________________________________________________Abstract:By means of a mathematical model, the main relations for the evaluation of the outer tip diameter on straight bevelgear with sum of the profile shift coefficients equal to zero are given. Additionally, some results associated with arational geometry and high load capacities of straight bevel gear with restrictions in the outer tip diameter arepresented. For the determination of the calculation procedures based on mathematical models was used thetechnique of representation by means of graphs.Key words: Straight bevel gear, rational design, mathematical models, graphs technique.

  3. Characterization of SCC crack tips and surface oxide layers in alloy 600

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Katsuhiko; Fukuya, Koji [Inst. of Nuclear Safety System Inc., Mihama, Fukui (Japan)

    2002-09-01

    In order to investigate the mechanism of primary water stress corrosion cracking (SCC), direct observation of microstructures of SCC crack tips and surface oxide layers in alloy 600 were carried out. A focused-ion beam (FIB) micro-processing technique was applied to prepare electron transparent foils including the crack tip and the surface oxide layer without any damage to those microstructures. Transmission electron microscopy and analysis were used to characterize the crack tips and surface oxide layers. Cr-rich oxides and a metal-Ni phase were identified in the crack tips and grain boundaries ahead of the crack tips independent of dissolved hydrogen concentrations. >From the fact that the Cr-rich oxides and metal-Ni phase were observed in the inner surface oxide layer, the same oxidation mechanism as the surface is proposed for the crack tip region and internal oxidation accompanying selective Cr oxidation is suggested as the mechanism. (author)

  4. Finite element modelling of radial lentotomy cuts to improve the accommodation performance of the human lens.

    Science.gov (United States)

    Burd, H J; Wilde, G S

    2016-04-01

    The use of a femtosecond laser to form planes of cavitation bubbles within the ocular lens has been proposed as a potential treatment for presbyopia. The intended purpose of these planes of cavitation bubbles (referred to in this paper as 'cutting planes') is to increase the compliance of the lens, with a consequential increase in the amplitude of accommodation. The current paper describes a computational modelling study, based on three-dimensional finite element analysis, to investigate the relationship between the geometric arrangement of the cutting planes and the resulting improvement in lens accommodation performance. The study is limited to radial cutting planes. The effectiveness of a variety of cutting plane geometries was investigated by means of modelling studies conducted on a 45-year human lens. The results obtained from the analyses depend on the particular modelling procedures that are employed. When the lens substance is modelled as an incompressible material, radial cutting planes are found to be ineffective. However, when a poroelastic model is employed for the lens substance, radial cuts are shown to cause an increase in the computed accommodation performance of the lens. In this case, radial cuts made in the peripheral regions of the lens have a relatively small influence on the accommodation performance of the lens; the lentotomy process is seen to be more effective when cuts are made near to the polar axis. When the lens substance is modelled as a poroelastic material, the computational results suggest that useful improvements in lens accommodation performance can be achieved, provided that the radial cuts are extended to the polar axis. Radial cuts are ineffective when the lens substance is modelled as an incompressible material. Significant challenges remain in developing a safe and effective surgical procedure based on this lentotomy technique.

  5. Dual-tip magnetic force microscopy with suppressed influence on magnetically soft samples

    International Nuclear Information System (INIS)

    Precner, Marián; Fedor, Ján; Šoltýs, Ján; Cambel, Vladimír

    2015-01-01

    Standard magnetic force microscopy (MFM) is considered as a powerful tool used for magnetic field imaging at nanoscale. The method consists of two passes realized by the magnetic tip. Within the first one, the topography pass, the magnetic tip directly touches the magnetic sample. Such contact perturbs the magnetization of the sample explored. To avoid the sample touching the magnetic tip, we present a new approach to magnetic field scanning by segregating the topological and magnetic scans with two different tips located on a cut cantilever. The approach minimizes the disturbance of sample magnetization, which could be a major problem in conventional MFM images of soft magnetic samples. By cutting the cantilever in half using the focused ion beam technique, we create one sensor with two different tips—one tip is magnetized, and the other one is left non-magnetized. The non-magnetized tip is used for topography and the magnetized one for the magnetic field imaging. The method developed we call dual-tip magnetic force microscopy (DT-MFM). We describe in detail the dual-tip fabrication process. In the experiments, we show that the DT-MFM method reduces significantly the perturbations of the magnetic tip as compared to the standard MFM method. The present technique can be used to investigate microscopic magnetic domain structures in a variety of magnetic samples and is relevant in a wide range of applications, e.g., data storage and biomedicine. (paper)

  6. Customized atomic force microscopy probe by focused-ion-beam-assisted tip transfer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Andrew; Butte, Manish J., E-mail: manish.butte@stanford.edu [Department of Pediatrics, Division of Immunology, Allergy and Rheumatology, Stanford University, Stanford, California 94305 (United States)

    2014-08-04

    We present a technique for transferring separately fabricated tips onto tipless atomic force microscopy (AFM) cantilevers, performed using focused ion beam-assisted nanomanipulation. This method addresses the need in scanning probe microscopy for certain tip geometries that cannot be achieved by conventional lithography. For example, in probing complex layered materials or tall biological cells using AFM, a tall tip with a high-aspect-ratio is required to avoid artifacts caused by collisions of the tip's sides with the material being probed. We show experimentally that tall (18 μm) cantilever tips fabricated by this approach reduce squeeze-film damping, which fits predictions from hydrodynamic theory, and results in an increased quality factor (Q) of the fundamental flexural mode. We demonstrate that a customized tip's well-defined geometry, tall tip height, and aspect ratio enable improved measurement of elastic moduli by allowing access to low-laying portions of tall cells (T lymphocytes). This technique can be generally used to attach tips to any micromechanical device when conventional lithography of tips cannot be accomplished.

  7. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  8. Thermal Diffusivity Measurements in Edible Oils using Transient Thermal Lens

    Science.gov (United States)

    Valdez, R. Carbajal.; Pérez, J. L. Jiménez.; Cruz-Orea, A.; Martín-Martínez, E. San.

    2006-11-01

    Time resolved thermal lens (TL) spectrometry is applied to the study of the thermal diffusivity of edible oils such as olive, and refined and thermally treated avocado oils. A two laser mismatched-mode experimental configuration was used, with a He Ne laser as a probe beam and an Ar+ laser as the excitation one. The characteristic time constant of the transient thermal lens was obtained by fitting the experimental data to the theoretical expression for a transient thermal lens. The results showed that virgin olive oil has a higher thermal diffusivity than for refined and thermally treated avocado oils. This measured thermal property may contribute to a better understanding of the quality of edible oils, which is very important in the food industry. The thermal diffusivity results for virgin olive oil, obtained from this technique, agree with those reported in the literature.

  9. An integral-field spectroscopic strong lens survey

    International Nuclear Information System (INIS)

    Bolton, Adam S; Burles, Scott

    2007-01-01

    We present the observational results of a survey for strong gravitational lens systems consisting of extended emission-line galaxies lensed by intervening early-type galaxies, conducted using integral field units (IFUs) of the Magellan IMACS and Gemini GMOS-N spectrographs. These data are highly valuable for corroborating the lensing interpretation of Hubble Space Telescope imaging data. We show that in many cases, ground-based IFU spectroscopy is in fact competitive with space-based imaging for the measurement of the mass model parameters of the lensing galaxy. We demonstrate a novel technique of three-dimensional gravitational lens modeling for a single lens system with a resolved lensed rotation curve. We also describe the details of our custom IFU data analysis software, which performs optimal multi-fiber extraction, relative and absolute wavelength calibration to a few hundredths of a pixel RMS and nearly Poisson-limited sky subtraction

  10. Projection model for flame chemiluminescence tomography based on lens imaging

    Science.gov (United States)

    Wan, Minggang; Zhuang, Jihui

    2018-04-01

    For flame chemiluminescence tomography (FCT) based on lens imaging, the projection model is essential because it formulates the mathematical relation between the flame projections captured by cameras and the chemiluminescence field, and, through this relation, the field is reconstructed. This work proposed the blurry-spot (BS) model, which takes more universal assumptions and has higher accuracy than the widely applied line-of-sight model. By combining the geometrical camera model and the thin-lens equation, the BS model takes into account perspective effect of the camera lens; by combining ray-tracing technique and Monte Carlo simulation, it also considers inhomogeneous distribution of captured radiance on the image plane. Performance of these two models in FCT was numerically compared, and results showed that using the BS model could lead to better reconstruction quality in wider application ranges.

  11. Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens

    Directory of Open Access Journals (Sweden)

    Vikas Veerwal

    2017-01-01

    Full Text Available Pigment dispersion syndrome (PDS is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.

  12. Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens.

    Science.gov (United States)

    Veerwal, Vikas; Goyal, Jawahar Lal; Jain, Parul; Arora, Ritu

    2017-01-01

    Pigment dispersion syndrome (PDS) is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA) of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.

  13. Tips for Postpartum Dads and Partners

    Science.gov (United States)

    ... Blues: Partners Interview with Wade Bowen Coping with Suicide & Loss Tips for Postpartum Dads and Partners Pregnancy and postpartum mood and anxiety disorders affect the whole family. Here are some tips ...

  14. Tips for Reducing Pesticide Impacts on Wildlife

    Science.gov (United States)

    This Web page provides tips for pesticide users in residential and agricultural settings, as well as tips for certified pesticide applicators for ways to protect wildlife from potentially harmful effects of pesticides.

  15. Tipping point analysis of ocean acoustic noise

    Science.gov (United States)

    Livina, Valerie N.; Brouwer, Albert; Harris, Peter; Wang, Lian; Sotirakopoulos, Kostas; Robinson, Stephen

    2018-02-01

    We apply tipping point analysis to a large record of ocean acoustic data to identify the main components of the acoustic dynamical system and study possible bifurcations and transitions of the system. The analysis is based on a statistical physics framework with stochastic modelling, where we represent the observed data as a composition of deterministic and stochastic components estimated from the data using time-series techniques. We analyse long-term and seasonal trends, system states and acoustic fluctuations to reconstruct a one-dimensional stochastic equation to approximate the acoustic dynamical system. We apply potential analysis to acoustic fluctuations and detect several changes in the system states in the past 14 years. These are most likely caused by climatic phenomena. We analyse trends in sound pressure level within different frequency bands and hypothesize a possible anthropogenic impact on the acoustic environment. The tipping point analysis framework provides insight into the structure of the acoustic data and helps identify its dynamic phenomena, correctly reproducing the probability distribution and scaling properties (power-law correlations) of the time series.

  16. Tipping point analysis of ocean acoustic noise

    Directory of Open Access Journals (Sweden)

    V. N. Livina

    2018-02-01

    Full Text Available We apply tipping point analysis to a large record of ocean acoustic data to identify the main components of the acoustic dynamical system and study possible bifurcations and transitions of the system. The analysis is based on a statistical physics framework with stochastic modelling, where we represent the observed data as a composition of deterministic and stochastic components estimated from the data using time-series techniques. We analyse long-term and seasonal trends, system states and acoustic fluctuations to reconstruct a one-dimensional stochastic equation to approximate the acoustic dynamical system. We apply potential analysis to acoustic fluctuations and detect several changes in the system states in the past 14 years. These are most likely caused by climatic phenomena. We analyse trends in sound pressure level within different frequency bands and hypothesize a possible anthropogenic impact on the acoustic environment. The tipping point analysis framework provides insight into the structure of the acoustic data and helps identify its dynamic phenomena, correctly reproducing the probability distribution and scaling properties (power-law correlations of the time series.

  17. Sound source location in cavitating tip vortices

    International Nuclear Information System (INIS)

    Higuchi, H.; Taghavi, R.; Arndt, R.E.A.

    1985-01-01

    Utilizing an array of three hydrophones, individual cavitation bursts in a tip vortex could be located. Theoretically, four hydrophones are necessary. Hence the data from three hydrophones are supplemented with photographic observation of the cavitating tip vortex. The cavitation sound sources are found to be localized to within one base chord length from the hydrofoil tip. This appears to correspond to the region of initial tip vortex roll-up. A more extensive study with a four sensor array is now in progress

  18. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  19. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  20. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  1. Chemical performance of multi-environment trials in lens (Lens culinaris M.).

    Science.gov (United States)

    Karadavut, Ufuk; Palta, Cetin

    2010-01-15

    Genotype-environment (GE) interaction has been a major effect to determine stable lens (Lens culinaris (Medik.) Merr.) cultivars for chemical composition in Turkey. Utilization of the lines depends on their agronomic traits and stability of the chemical composition in diverse environments. The objectives of this study were: (i) to evaluate the influence of year and location on the chemical composition of lens genotypes; and (ii) to determine which cultivar is the most stable. Genotypes were evaluated over 3 years (2005, 2006 and 2007) at four locations in Turkey. Effects of year had the largest impact on all protein contents. GE interaction was analyzed by using linear regression techniques. Stability was estimated using the Eberhart and Russell method. 'Kişlik Kirmizi51' was the most stable cultivar for grain yield. The highest protein was obtained from 'Kişlik Kirmizi51' (4.6%) across environments. According to stability analysis, 'Firat 87' had the most stable chemical composition. This genotype had a regression coefficient (b(i) = 1) around unity, and deviations from regression values (delta(ij) = 0) around zero. Chemical composition was affected by year in this study. Temperature might have an effect on protein, oil, carbohydrate, fibre and ash. Firat 87 could be recommended for favourable environments. Copyright (c) 2009 Society of Chemical Industry.

  2. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    Science.gov (United States)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  3. Injector tip for an internal combustion engine

    Science.gov (United States)

    Shyu, Tsu Pin; Ye, Wen

    2003-05-20

    This invention relates to a the tip structure of a fuel injector as used in a internal combustion engine. Internal combustion engines using Homogeneous Charge Compression Ignition (HCCI) technology require a tip structure that directs fuel spray in a downward direction. This requirement necessitates a tip design that is capable of withstanding mechanical stresses associated with the design.

  4. Optimized lens-sparing treatment of retinoblastoma with electron beams

    International Nuclear Information System (INIS)

    Steenbakkers, Roel J.H.M.; Altschuler, Martin D.; D'Angio, Giulio J.; Goldwein, Joel W.; Kassaee, Alireza

    1997-01-01

    Purpose: The ideal lens-sparing radiotherapy technique for retinoblastoma calls for 100% dose to the entire retina including the ora serrata and zero dose to the lens. Published techniques, most of which use photons, have not accomplished this ideal treatment. We describe here a technique that approaches this ideal configuration using electron beam therapy. Methods and Materials: Dose-modeling calculations were made using a computer program built around a proprietary algorithm. This program calculates 3D dose distribution for electrons and photons and uses the Cimmino feasibility method for the inverse problem of beam weighting to achieve the prescribed dose. The algorithm has been verified in the ocular region by measurements in a RANDO phantom. To search for an ideal lens-sparing beam setup, a stylized phantom of an 8-month-old infant was generated with built-in inhomogeneities, and a phantom of a 5-year-old child was generated from a patient CT series. Results: Of more than 100 different beam setups tested, two 9 MeV electron beams at gantry angles plus and minus 26 degrees from the optic nerve axis achieved the best distribution. Both fields have a lens block and an isocenter between the globe and origin of the optic nerve. When equal doses are given to both fields, the entire extent of the retina (including ora serrata) received 100%, while the lens received 10% or less. Conclusion: The two-oblique-electron-beam technique here described appears to meet most of the stringent dosimetry needed to treat retinoblastoma. It is suitable for a range of ages, from infancy to early childhood years

  5. Lens system for SIMS analysis

    International Nuclear Information System (INIS)

    Martinez, G.; Sancho, M.; Garcia-Galan, J.C.

    1987-01-01

    A powerful version of the charge-density method is applied to the study of a combined objective and emission lens, suitable for highly localized analysis of a flat sample surface. This lens can extract secondary ions of equal or opposite polarity to that of the primary particles. A computer simulation of the ion trajectories for both modes is made. The behaviour for different values of the geometric parameters and polarizations is analyzed and useful data for design such as primary beam demagnification and secondary image position are given. (author) 4 refs

  6. Micro/nanosized refractive lens arrays formed by means of conformal thin film deposition

    International Nuclear Information System (INIS)

    Zeng Hongjun; Lajos, Robert; Elzy, Ed; Metlushko, Vitali

    2008-01-01

    We provide a 'growing' method for fabricating a microlens array with lateral size of a few microns or less. Instead of using complicated etching techniques, the method forms a spherical profile of the lens using conformal chemical vapor deposition. We have fabricated two lens arrays. One has a pitch of 1200 nm, a circular aperture 1000 nm in diameter and a sag height of 130 nm. The other array has a pitch of 600 nm, and a square aperture of 600 nm x 600 nm, with a fill factor close to 100%. The maximum profile deviation between the fabricated lens and an ideal sphere is about 11% and 14% respectively. The calculation indicates that the curvature difference of the profile of the square lens in the orthogonal and diagonal direction is 5.5%. The roughness of the lens is measured as approximately 6 nm

  7. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  8. Nanomechanical probing of soft matter through hydrophobic AFM tips fabricated by two-photon polymerization

    International Nuclear Information System (INIS)

    Suriano, Raffaella; De Marco, Carmela; Turri, Stefano; Zandrini, Tommaso; Osellame, Roberto; Bragheri, Francesca

    2016-01-01

    Atomic force microscopy (AFM) nanoindentation of soft materials is a powerful tool for probing mechanical properties of biomaterials. Though many results have been reported in this field over the last decade, adhesion forces between the tip and the sample hinder the elastic modulus measurement when hydrophilic soft samples are investigated. Here, two-photon polymerization (2PP) technology was used to fabricate hydrophobic perfluoropolyether-based AFM tips. The hydrophobic 2PP tips allowed us to overcome the limitations of commercial and functionalized tips as well as to successfully measure the elastic modulus of medically relevant soft materials in air. Our results obtained in the characterization of poly(dimethyl siloxane) and polyethylene glycol hydrogels showed lower adhesion forces over a larger measurement range when compared to measurements performed with commercial tips. The elastic moduli measured by means of hydrophobic 2PP AFM tips were also found to be comparable to those obtained using conventional techniques for macroscopic samples. We successfully showed that the hydrophobic AFM tips developed by this highly versatile technology enable the study of mechanical properties of soft matter, benefiting from reduced sample–tip interactions, and a custom-made shape and dimension of the tips. (paper)

  9. Electron beam fabrication and characterization of high-resolution magnetic force microscopy tips

    Science.gov (United States)

    Rührig, M.; Porthun, S.; Lodder, J. C.; McVitie, S.; Heyderman, L. J.; Johnston, A. B.; Chapman, J. N.

    1996-03-01

    The stray field, magnetic microstructure, and switching behavior of high-resolution electron beam fabricated thin film tips for magnetic force microscopy (MFM) are investigated with different imaging modes in a transmission electron microscope (TEM). As the tiny smooth carbon needles covered with a thermally evaporated magnetic thin film are transparent to the electron energies used in these TEMs it is possible to observe both the external stray field emanating from the tips as well as their internal domain structure. The experiments confirm the basic features of electron beam fabricated thin film tips concluded from various MFM observations using these tips. Only a weak but highly concentrated stray field is observed emanating from the immediate apex region of the tip, consistent with their capability for high resolution. It also supports the negligible perturbation of the magnetization sample due to the tip stray field observed in MFM experiments. Investigation of the magnetization distributions within the tips, as well as preliminary magnetizing experiments, confirm a preferred single domain state of the high aspect ratio tips. To exclude artefacts of the observation techniques both nonmagnetic tips and those supporting different magnetization states are used for comparison.

  10. Stretchable Binary Fresnel Lens for Focus Tuning

    NARCIS (Netherlands)

    Li, X.; Wei, L.; Poelma, R.H.; Vollebregt, S.; Wei, J.; Urbach, Paul; Sarro, P.M.; Zhang, G.Q.

    2016-01-01

    This paper presents a tuneable binary amplitude Fresnel lens produced by wafer-level microfabrication. The Fresnel lens is fabricated by encapsulating lithographically defined vertically aligned carbon nanotube (CNT) bundles inside a polydimethyl-siloxane (PDMS) layer. The composite lens material

  11. 21 CFR 886.1400 - Maddox lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maddox lens. 886.1400 Section 886.1400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1400 Maddox lens. (a) Identification. A Maddox lens is a device...

  12. Crystalline lens power and refractive error.

    Science.gov (United States)

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P lens opacity grade (β = -0.42; P lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  13. 21 CFR 886.3600 - Intraocular lens.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  14. Efficient generation of lens progenitor cells from cataract patient-specific induced pluripotent stem cells.

    Directory of Open Access Journals (Sweden)

    Xiaodi Qiu

    Full Text Available The development of a technique to induce the transformation of somatic cells to a pluripotent state via the ectopic expression of defined transcription factors was a transformational event in the field of regenerative medicine. The development of this technique also impacted ophthalmology, as patient-specific induced pluripotent stemcells (iPSCs may be useful resources for some ophthalmological diseases. The lens is a key refractive element in the eye that focuses images of the visual world onto the retina. To establish a new model for drug screening to treat lens diseases and investigating lens aging and development, we examined whether human lens epithelial cells (HLECs could be induced into iPSCs and if lens-specific differentiation of these cells could be achieved under defined chemical conditions. We first efficiently reprogrammed HLECs from age-related cataract patients to iPSCs with OCT-4, SOX-2, and KLF-4. The resulting HLEC-derived iPS (HLE-iPS colonies were indistinguishable from human ES cells with respect to morphology, gene expression, pluripotent marker expression and their ability to generate all embryonic germ-cell layers. Next, we performed a 3-step induction procedure: HLE-iPS cells were differentiated into large numbers of lens progenitor-like cells with defined factors (Noggin, BMP and FGF2, and we determined that these cells expressed lens-specific markers (PAX6, SOX2, SIX3, CRYAB, CRYAA, BFSP1, and MIP. In addition, HLE-iPS-derived lens cells exhibited reduced expression of epithelial mesenchymal transition (EMT markers compared with human embryonic stem cells (hESCs and fibroblast-derived iPSCs. Our study describes a highly efficient procedure for generating lens progenitor cells from cataract patient HLEC-derived iPSCs. These patient-derived pluripotent cells provide a valuable model for studying the developmental and molecular biological mechanisms that underlie cell determination in lens development and cataract

  15. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  16. Tip-enhanced Raman mapping with top-illumination AFM.

    Science.gov (United States)

    Chan, K L Andrew; Kazarian, Sergei G

    2011-04-29

    Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of ∼ 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.

  17. Tip-enhanced Raman mapping with top-illumination AFM

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K L Andrew; Kazarian, Sergei G, E-mail: s.kazarian@imperial.ac.uk [Department of Chemical Engineering, Imperial College London, SW7 2AZ (United Kingdom)

    2011-04-29

    Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of {approx} 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.

  18. Tip-enhanced Raman mapping with top-illumination AFM

    International Nuclear Information System (INIS)

    Chan, K L Andrew; Kazarian, Sergei G

    2011-01-01

    Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of ∼ 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.

  19. Qualification of a Null Lens Using Image-Based Phase Retrieval

    Science.gov (United States)

    Bolcar, Matthew R.; Aronstein, David L.; Hill, Peter C.; Smith, J. Scott; Zielinski, Thomas P.

    2012-01-01

    In measuring the figure error of an aspheric optic using a null lens, the wavefront contribution from the null lens must be independently and accurately characterized in order to isolate the optical performance of the aspheric optic alone. Various techniques can be used to characterize such a null lens, including interferometry, profilometry and image-based methods. Only image-based methods, such as phase retrieval, can measure the null-lens wavefront in situ - in single-pass, and at the same conjugates and in the same alignment state in which the null lens will ultimately be used - with no additional optical components. Due to the intended purpose of a Dull lens (e.g., to null a large aspheric wavefront with a near-equal-but-opposite spherical wavefront), characterizing a null-lens wavefront presents several challenges to image-based phase retrieval: Large wavefront slopes and high-dynamic-range data decrease the capture range of phase-retrieval algorithms, increase the requirements on the fidelity of the forward model of the optical system, and make it difficult to extract diagnostic information (e.g., the system F/#) from the image data. In this paper, we present a study of these effects on phase-retrieval algorithms in the context of a null lens used in component development for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Approaches for mitigation are also discussed.

  20. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  1. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  2. Treatment of a dislocated lens by transcorneal vitrectomy and bimanual phacoemulsification

    Directory of Open Access Journals (Sweden)

    Watanabe A

    2014-08-01

    Full Text Available Akira Watanabe, Tamaki Gekka, Hiroshi Tsuneoka Department of Ophthalmology, The Jikei University School of Medicine, Tokyo, Japan Background: As a method of treatment for a dropped lens nucleus, which occurred during cataract surgery, the dropped lens nucleus was removed through the corneal wound without using pars plana vitrectomy (PPV. After vitrectomy, the dropped lens nucleus was floated on the perfluorocarbon liquid (PFCL. The floating lens nucleus was then phacoemulsified and aspirated. During surgery, irrigation from the anterior chamber was performed. This method was very effective for treatment of a dropped hard nucleus.Case report: During cataract surgery on the left eye of an 80-year-old woman, a posterior capsule rupture occurred. As a result, the lens nucleus dropped into the vitreous cavity. Irrigation to the anterior chamber was performed, with an anterior chamber maintainer inserted through a newly created side port at the corneal limbus. A vitreous cutter and a light guide were inserted in order to perform vitrectomy through the corneal incisions that were created for the cataract surgery. After vitrectomy, the dropped lens nucleus was floated using PFCL. The floating lens nucleus was removed by a bimanual phacoemulsification technique, with the anterior chamber irrigation continuing. The separation of the irrigation port and the aspiration port allowed for effective treatment of the dropped nucleus that was floating on the PFCL, even using a ­phacoemulsification machine with a peristaltic pump system. Safe and effective vitrectomy, similar to a PPV, could be performed with this method using three corneal ports.Conclusion: This technique may allow safer and more effective treatment for a dropped lens nucleus compared with conventional PPV. With this technique, corneal distortion due to surgical manipulation can lead to reduced visibility of the posterior eye. Keywords: dislocated lens, transcorneal vitrectomy, bimanual

  3. Functionalization of atomic force microscope tips by dielectrophoretic assembly of Gd2O3:Eu3+ nanorods

    International Nuclear Information System (INIS)

    Macedo, Andreia G; Ananias, Duarte; Andre, Paulo S; Ferreira, Rute A sa; Carlos, Luis D; Kholkin, Andrei L; Rocha, J

    2008-01-01

    An atomic force microscopy (AFM) tip has been coated with photoluminescent Eu 3+ -doped Gd 2 O 3 nanorods using a dielectrophoresis technique, which preserves the red emission of the nanorods (quantum yield 0.47). The performance of the modified tips has been tested by using them for regular topography imaging in tapping and contact modes. Both a regular AFM standard grid and a patterned surface (of an organic-inorganic methacrylate Zr-based oxo-cluster and poly(oxyethylene)/siloxane hybrid) have been used. Similar depth values have been measured using a conventional silicon tip and the nanorod-modified tip. The tips before and after use exhibit similar SEM images and photoluminescence spectra and, thus, seem to be stable under working conditions. These tips should find applications in scanning near-field optical microscopy and other scanning techniques

  4. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  5. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  6. Plasma Lens for Muon and Neutrino Beams

    Science.gov (United States)

    Kahn, Stephen; Korenev, Sergey; Bishai, Mary; Diwan, Milind; Gallardo, Juan; Hershcovitch, Ady; Johnson, Brant

    2008-04-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-current lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. A plasma lens has additional advantage: larger axial current than horns, minimal neutrino contamination during antineutrino running, and negligible pion absorption or scattering. Results from particle simulations using a plasma lens will be presented.

  7. Twitter Tips, Tricks, and Tweets

    CERN Document Server

    McFedries, Paul

    2010-01-01

    Maximize your fun and boost your productivity with this updated, full-color guide to tantalizing Twitter tips!. The popularity of Twitter continues to soar, and is fast becoming the most popular social networking site online. Whether you're looking to learn how to set up an account for the first time or are on the prowl for some cool third-party Twitter apps, this full-color guide will boost your entire Twitter experience. Allowing you to communicate with fellow Twitters within a 140-character limit, this fun and fascinating social networking tool is easier than maintaining a blog and quicker

  8. Windows 8 visual quick tips

    CERN Document Server

    McFedries, Paul

    2012-01-01

    Easy-in, easy-out format covers all the bells and whistles of Windows 8 If you want to learn how to work smarter and faster in Microsoft's Windows 8 operating system, this easy-to-use, compact guide delivers the goods. Designed for visual learners, it features short explanations and full-color screen shots on almost every page, and it's packed with timesaving tips and helpful productivity tricks. From enhancing performance and managing digital content to setting up security and much more, this handy guide will help you get more out of Windows 8. Uses full-color screen shots and short, step-by-

  9. Integrated Lens Antennas for Multi-Pixel Receivers

    Science.gov (United States)

    Lee, Choonsup; Chattopadhyay, Goutam

    2011-01-01

    Future astrophysics and planetary experiments are expected to require large focal plane arrays with thousands of detectors. Feedhorns have excellent performance, but their mass, size, fabrication challenges, and expense become prohibitive for very large focal plane arrays. Most planar antenna designs produce broad beam patterns, and therefore require additional elements for efficient coupling to the telescope optics, such as substrate lenses or micromachined horns. An antenna array with integrated silicon microlenses that can be fabricated photolithographically effectively addresses these issues. This approach eliminates manual assembly of arrays of lenses and reduces assembly errors and tolerances. Moreover, an antenna array without metallic horns will reduce mass of any planetary instrument significantly. The design has a monolithic array of lens-coupled, leaky-wave antennas operating in the millimeter- and submillimeter-wave frequencies. Electromagnetic simulations show that the electromagnetic fields in such lens-coupled antennas are mostly confined in approximately 12 15 . This means that one needs to design a small-angle sector lens that is much easier to fabricate using standard lithographic techniques, instead of a full hyper-hemispherical lens. Moreover, this small-angle sector lens can be easily integrated with the antennas in an array for multi-pixel imager and receiver implementation. The leaky antenna is designed using double-slot irises and fed with TE10 waveguide mode. The lens implementation starts with a silicon substrate. Photoresist with appropriate thickness (optimized for the lens size) is spun on the substrate and then reflowed to get the desired lens structure. An antenna array integrated with individual lenses for higher directivity and excellent beam profile will go a long way in realizing multi-pixel arrays and imagers. This technology will enable a new generation of compact, low-mass, and highly efficient antenna arrays for use in multi

  10. The use of functionalized AFM tips as molecular sensors in the detection of pesticides

    International Nuclear Information System (INIS)

    Deda, Daiana K.; Pereira, Barbara B.S.; Bueno, Carolina C.; Silva, Aline N. da; Ribeiro, Gabrielle A.; Amarante, Adriano M.; Leite, Fabio L.; Franca, Eduardo F.

    2013-01-01

    Atomic force spectroscopy, a technique derived from Atomic Force Microscopy (AFM), allowed to distinguish nonspecific and specific interactions between the acetolactate synthase enzyme (ALS) and anti-atrazine antibody biomolecules and the herbicides imazaquin, metsulfuron-methyl and atrazine. The presence of specific interactions increased the adhesion force (F adh ) between the AFM tip and the herbicides, which made the modified tip a powerful biosensor. Increases of approximately 132% and 145% in the F adh values were observed when a tip functionalized with ALS was used to detect imazaquin and metsulfuron-methyl, respectively. The presence of specific interactions between the atrazine and the anti-atrazine antibody also caused an increase in the F adh values (approximately 175%) compared to those observed when using an unfunctionalized tip. The molecular modeling results obtained with the ALS enzyme suggest that the orientation of the biomolecule on the tip surface could be suitable for allowing interaction with the herbicides imazaquin and metsulfuron-methyl. (author)

  11. The use of functionalized AFM tips as molecular sensors in the detection of pesticides

    Directory of Open Access Journals (Sweden)

    Daiana K. Deda

    2013-06-01

    Full Text Available Atomic force spectroscopy, a technique derived from Atomic Force Microscopy (AFM, allowed us to distinguish nonspecific and specific interactions between the acetolactate synthase enzyme (ALS and anti-atrazine antibody biomolecules and the herbicides imazaquin, metsulfuron-methyl and atrazine. The presence of specific interactions increased the adhesion force (Fadh between the AFM tip and the herbicides, which made the modified tip a powerful biosensor. Increases of approximately 132% and 145% in the Fadh values were observed when a tip functionalized with ALS was used to detect imazaquin and metsulfuron-methyl, respectively. The presence of specific interactions between the atrazine and the anti-atrazine antibody also caused an increase in the Fadh values (approximately 175% compared to those observed when using an unfunctionalized tip. The molecular modeling results obtained with the ALS enzyme suggest that the orientation of the biomolecule on the tip surface could be suitable for allowing interaction with the herbicides imazaquin and metsulfuron-methyl.

  12. Adjusting the displaced tip of peripherally inserted central catheter under DSA guidance

    International Nuclear Information System (INIS)

    Mao Yanjun; Dong Huijuan; Zhang Lingjuan; Li Hongmei; Xu Lianqin

    2009-01-01

    Objective: To explore a new method to adjust the displaced tip of peripherally inserted central catheter (PICC) under DSA guidance. Methods: Under DSA guidance, the displaced tip of PICC was repositioned to the ideal junction area of superior vena cava with right atrium with proper manipulation. Results: Under DSA guidance, the displaced tip of PICC was successfully corrected in 13 cases. The mean operative time was 15.53 minutes, which was markedly shorter than that needed by blind adjusting beside the bed. Conclusion: The displacement of PICC tip is a common occurrence, which is hard to be avoided. Under DSA guidance, the adjusting manipulation of the displaced PICC tip is safe and time-saving with high successful rate. It is worth popularizing this technique in clinical practice. (authors)

  13. Metamaterial-based half Maxwell fish-eye lens for broadband directive emissions

    Science.gov (United States)

    Dhouibi, Abdallah; Nawaz Burokur, Shah; de Lustrac, André; Priou, Alain

    2013-01-01

    The broadband directive emission from a metamaterial surface is numerically and experimentally reported. The metasurface, composed of non-resonant complementary closed ring structures, is designed to obey the refractive index of a half Maxwell fish-eye lens. A planar microstrip Vivaldi antenna is used as transverse magnetic polarized wave launcher for the lens. A prototype of the lens associated with its feed structure has been fabricated using standard lithography techniques. To experimentally demonstrate the broadband focusing properties and directive emissions, both the far-field radiation patterns and the near-field distributions have been measured. Measurements agree quantitatively and qualitatively with theoretical simulations.

  14. Eyeglasses Lens Contour Extraction from Facial Images Using an Efficient Shape Description

    Directory of Open Access Journals (Sweden)

    Diana Borza

    2013-10-01

    Full Text Available This paper presents a system that automatically extracts the position of the eyeglasses and the accurate shape and size of the frame lenses in facial images. The novelty brought by this paper consists in three key contributions. The first one is an original model for representing the shape of the eyeglasses lens, using Fourier descriptors. The second one is a method for generating the search space starting from a finite, relatively small number of representative lens shapes based on Fourier morphing. Finally, we propose an accurate lens contour extraction algorithm using a multi-stage Monte Carlo sampling technique. Multiple experiments demonstrate the effectiveness of our approach.

  15. Photoshop CC top 100 simplified tips and tricks

    CERN Document Server

    Sholik, Stan

    2013-01-01

    Take your Photoshop skill set to the next level with these essential techniques If you're already familiar with Photoshop basics and are ready to learn some new tips, tricks, and techniques, then this is the book for you! Full-color, step-by-step instructions take you beyond the essentials and show you how to make the most of the newest features of Photoshop CC (Creative Cloud). Beautiful photos will inspire you to experiment with Photoshop's features, and numbered instructions make the techniques easy to learn. Encourages you to expand your skill set with creative, or

  16. Fat grafting and breast reconstruction: tips for ensuring predictability.

    Science.gov (United States)

    Gabriel, Allen; Champaneria, Manish C; Maxwell, G Patrick

    2015-06-01

    Autologous fat grafting is widely used in breast surgery to refine and optimize aesthetic outcomes. Despite its widespread use, obtaining predictable, reliable, and consistent outcomes remains a significant challenge and is influenced by the technique used for procurement, processing, and placement of the fat. At present, there is no published consensus on the optimal technique. The purpose of this article is to review current techniques at each stage of fat grafting and provide tips on best practices based on the published literature as well as our extensive clinical experience.

  17. Scleral fixation of a single-piece multifocal intraocular lens.

    Science.gov (United States)

    Can, Ertugrul; Basaran, M Resat; Gül, Adem

    2013-01-01

    We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectacle-corrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL.

  18. Towards easy and reliable AFM tip shape determination using blind tip reconstruction

    International Nuclear Information System (INIS)

    Flater, Erin E.; Zacharakis-Jutz, George E.; Dumba, Braulio G.; White, Isaac A.; Clifford, Charles A.

    2014-01-01

    Quantitative determination of the geometry of an atomic force microscope (AFM) probe tip is critical for robust measurements of the nanoscale properties of surfaces, including accurate measurement of sample features and quantification of tribological characteristics. Blind tip reconstruction, which determines tip shape from an AFM image scan without knowledge of tip or sample shape, was established most notably by Villarrubia [J. Res. Natl. Inst. Stand. Tech. 102 (1997)] and has been further developed since that time. Nevertheless, the implementation of blind tip reconstruction for the general user to produce reliable and consistent estimates of tip shape has been hindered due to ambiguity about how to choose the key input parameters, such as tip matrix size and threshold value, which strongly impact the results of the tip reconstruction. These key parameters are investigated here via Villarrubia's blind tip reconstruction algorithms in which we have added the capability for users to systematically vary the key tip reconstruction parameters, evaluate the set of possible tip reconstructions, and determine the optimal tip reconstruction for a given sample. We demonstrate the capabilities of these algorithms through analysis of a set of simulated AFM images and provide practical guidelines for users of the blind tip reconstruction method. We present a reliable method to choose the threshold parameter corresponding to an optimal reconstructed tip shape for a given image. Specifically, we show that the trend in how the reconstructed tip shape varies with threshold number is so regular that the optimal, or Goldilocks, threshold value corresponds with the peak in the derivative of the RMS difference with respect to the zero threshold curve vs. threshold number. - Highlights: • Blind tip reconstruction algorithms have been implemented and augmented to determine the optimal input parameters. • We demonstrate the capabilities of the algorithms using a simulated AFM

  19. Influence of the tip mass on the tip-sample interactions in TM-AFM

    Energy Technology Data Exchange (ETDEWEB)

    Pishkenari, Hossein Nejat, E-mail: nejat@mech.sharif.edu [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of); Meghdari, Ali [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of)

    2011-07-15

    This paper focuses on the influences of the tip mass ratio (the ratio of the tip mass to the cantilever mass), on the excitation of higher oscillation eigenmodes and also on the tip-sample interaction forces in tapping mode atomic force microscopy (TM-AFM). A precise model for the cantilever dynamics capable of accurate simulations is essential for the investigation of the tip mass effects on the interaction forces. In the present work, the finite element method (FEM) is used for modeling the AFM cantilever to consider the oscillations of higher eigenmodes oscillations. In addition, molecular dynamics (MD) is used to calculate precise data for the tip-sample force as a function of tip vertical position with respect to the sample. The results demonstrate that in the presence of nonlinear tip-sample interaction forces, the tip mass ratio plays a significant role in the excitations of higher eigenmodes and also in the normal force applied on the surface. Furthermore, it has been shown that the difference between responses of the FEM and point-mass models in different system operational conditions is highly affected by the tip mass ratio. -- Highlights: {yields} A strong correlation exists between the tip mass ratio and the 18th harmonic amplitude. {yields} Near the critical tip mass ratio a small change in the tip mass may lead to a significant force change. {yields} Inaccuracy of the lumped model depends significantly on the tip mass ratio.

  20. Tip Clearance Control Using Plasma Actuators

    Science.gov (United States)

    2007-03-01

    Clearance Control Using Plasma Actuators 4 posed by Denton (1993). A number of investigators have used partial shrouds, or " winglet " designs to...SDBD actuator Plasma enhanced aerodynamics has been demonstrated in a range of applications involving sepa- ration control, lift enhancement, drag... aerodynamic benefits of a squealer tip geometry. Specifically, the squealer tip is known to reduce the discharge coefficient of the tip gap, thereby

  1. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  2. Lens Coupled Quantum Cascade Laser

    Science.gov (United States)

    Hu, Qing (Inventor); Lee, Alan Wei Min (Inventor)

    2013-01-01

    Terahertz quantum cascade (QC) devices are disclosed that can operate, e.g., in a range of about 1 THz to about 10 THz. In some embodiments, QC lasers are disclosed in which an optical element (e.g., a lens) is coupled to an output facet of the laser's active region to enhance coupling of the lasing radiation from the active region to an external environment. In other embodiments, terahertz amplifier and tunable terahertz QC lasers are disclosed.

  3. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  4. Gradual approach to refinement of the nasal tip: surgical results

    Directory of Open Access Journals (Sweden)

    Thiago Bittencourt Ottoni de Carvalho

    2015-02-01

    Full Text Available Introduction: The complexity of the nasal tip structures and the impact of surgical maneuvers make the prediction of the final outcome very difficult. Therefore, no single technique is enough to correct the several anatomical presentations, and adequate preoperative planning represents the basis of rhinoplasty. Objective: To present results of rhinoplasty, through the gradual surgical approach to nasal tip definition based on anatomical features, and to evaluate the degree of patient satisfaction after the surgical procedure. Methods: Longitudinal retrospective cohort study of the medical charts of 533 patients of both genders who underwent rhinoplasty from January of 2005 to January of 2012 was performed. Cases were allocated into seven groups: (1 no surgery on nasal tip; (2 interdomal breakup; (3 cephalic trim; (4 domal suture; (5 shield-shaped graft; (6 vertical dome division; (7 replacement of lower lateral cartilages. Results: Group 4 was the most prevalent. The satisfaction rate was 96% and revision surgery occurred in 4% of cases. Conclusion: The protocol used allowed the implementation of a gradual surgical approach to nasal tip definition with the nasal anatomical characteristics, high rate of patient satisfaction with the surgical outcome, and low rate of revision.

  5. Rotating coherent flow structures as a source for narrowband tip clearance noise from axial fans

    Science.gov (United States)

    Zhu, Tao; Lallier-Daniels, Dominic; Sanjosé, Marlène; Moreau, Stéphane; Carolus, Thomas

    2018-03-01

    Noise from axial fans typically increases significantly as the tip clearance is increased. In addition to the broadband tip clearance noise at the design flow rate, narrowband humps also associated with the tip flow are observed in the far-field acoustic spectra at lower flow rate. In this study, both experimental and numerical methods are used to shed more light on the noise generation mechanism of this narrowband tip clearance noise and provide a unified description of this source. Unsteady aeroacoustic predictions with the Lattice-Boltzmann Method (LBM) are successfully compared with experiment. Such a validation allows using LBM data to conduct a detailed modal analysis of the pressure field for detecting rotating coherent flow structures which might be considered as noise sources. As previously found in ring fans the narrowband humps in the far-field noise spectra are found to be related to the tip clearance noise that is generated by an interaction of coherent flow structures present in the tip region with the leading edge of the impeller blades. The visualization of the coherent structures shows that they are indeed part of the unsteady tip clearance vortex structures. They are hidden in a complex, spatially and temporally inhomogeneous flow field, but can be recovered by means of appropriate filtering techniques. Their pressure trace corresponds to the so-called rotational instability identified in previous turbomachinery studies, which brings a unified picture of this tip-noise phenomenon for the first time.

  6. Quantitative analysis of tip-sample interaction in non-contact scanning force spectroscopy

    International Nuclear Information System (INIS)

    Palacios-Lidon, Elisa; Colchero, Jaime

    2006-01-01

    Quantitative characterization of tip-sample interaction in scanning force microscopy is fundamental for optimum image acquisition as well as data interpretation. In this work we discuss how to characterize the electrostatic and van der Waals contribution to tip-sample interaction in non-contact scanning force microscopy precisely. The spectroscopic technique presented is based on the simultaneous measurement of cantilever deflection, oscillation amplitude and frequency shift as a function of tip-sample voltage and tip-sample distance as well as on advanced data processing. Data are acquired at a fixed lateral position as interaction images, with the bias voltage as fast scan, and tip-sample distance as slow scan. Due to the quadratic dependence of the electrostatic interaction with tip-sample voltage the van der Waals force can be separated from the electrostatic force. Using appropriate data processing, the van der Waals interaction, the capacitance and the contact potential can be determined as a function of tip-sample distance. The measurement of resonance frequency shift yields very high signal to noise ratio and the absolute calibration of the measured quantities, while the acquisition of cantilever deflection allows the determination of the tip-sample distance

  7. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  8. Glycation precedes lens crystallin aggregation

    International Nuclear Information System (INIS)

    Swamy, M.S.; Perry, R.E.; Abraham, E.C.

    1987-01-01

    Non-enzymatic glycosylation (glycation) seems to have the potential to alter the structure of crystallins and make them susceptible to thiol oxidation leading to disulfide-linked high molecular weight (HMW) aggregate formation. They used streptozotocin diabetic rats during precataract and cataract stages and long-term cell-free glycation of bovine lens crystallins to study the relationship between glycation and lens crystallin aggregation. HMW aggregates and other protein components of the water-soluble (WS) and urea-soluble (US) fractions were separated by molecular sieve high performance liquid chromatography. Glycation was estimated by both [ 3 H]NaBH 4 reduction and phenylboronate agarose affinity chromatography. Levels of total glycated protein (GP) in the US fractions were about 2-fold higher than in the WS fractions and there was a linear increase in GP in both WS and US fractions. This increase was parallelled by a corresponding increase in HMW aggregates. Total GP extracted by the affinity method from the US fraction showed a predominance of HMW aggregates and vice versa. Cell-free glycation studies with bovine crystallins confirmed the results of the animals studies. Increasing glycation caused a corresponding increase in protein insolubilization and the insoluble fraction thus formed also contained more glycated protein. It appears that lens protein glycation, HMW aggregate formation, and protein insolubilization are interrelated

  9. RANS computations of tip vortex cavitation

    Science.gov (United States)

    Decaix, Jean; Balarac, Guillaume; Dreyer, Matthieu; Farhat, Mohamed; Münch, Cécile

    2015-12-01

    The present study is related to the development of the tip vortex cavitation in Kaplan turbines. The investigation is carried out on a simplified test case consisting of a NACA0009 blade with a gap between the blade tip and the side wall. Computations with and without cavitation are performed using a R ANS modelling and a transport equation for the liquid volume fraction. Compared with experimental data, the R ANS computations turn out to be able to capture accurately the development of the tip vortex. The simulations have also highlighted the influence of cavitation on the tip vortex trajectory.

  10. Direct calculation of wind turbine tip loss

    DEFF Research Database (Denmark)

    Wood, D.H.; Okulov, Valery; Bhattacharjee, D.

    2016-01-01

    . We develop three methods for the direct calculation of the tip loss. The first is the computationally expensive calculation of the velocities induced by the helicoidal wake which requires the evaluation of infinite sums of products of Bessel functions. The second uses the asymptotic evaluation......The usual method to account for a finite number of blades in blade element calculations of wind turbine performance is through a tip loss factor. Most analyses use the tip loss approximation due to Prandtl which is easily and cheaply calculated but is known to be inaccurate at low tip speed ratio...

  11. Spontaneous resorption of sub-retinal cortical lens material

    Directory of Open Access Journals (Sweden)

    Salil S Gadkari

    2014-01-01

    Full Text Available We report a rare case of retained sub-retinal cortical material, which underwent spontaneous resorption. Patient presented with a left eye traumatic retinal detachment with a large retinal tear and posteriorly dislocated cataractous lens. Vitrectomy, lensectomy, silicone oil injection, and endolaser were performed. A good visual result was achieved. The report draws attention to this condition and highlights possible technique for minimizing risk of this complication in similar cases.

  12. Ultrafast Degenerate Transient Lens Spectroscopy in Semiconductor Nanosctructures

    Directory of Open Access Journals (Sweden)

    Leontyev A.V.

    2015-01-01

    Full Text Available We report the non-resonant excitation and probing of the nonlinear refractive index change in bulk semiconductors and semiconductor quantum dots through degenerate transient lens spectroscopy. The signal oscillates at the center laser field frequency, and the envelope of the former in quantum dots is distinctly different from the one in bulk sample. We discuss the applicability of this technique for polarization state probing in semiconductor media with femtosecond temporal resolution.

  13. The Effect of the Crystalline Lens on Central Vault After Implantable Collamer Lens Implantation.

    Science.gov (United States)

    Qi, Meng-Ying; Chen, Qian; Zeng, Qing-Yan

    2017-08-01

    To identify associations between crystalline lens-related factors and central vault after Implantable Collamer Lens (ICL) (Staar Surgical, Monrovia, CA) implantation. This retrospective clinical study included 320 eyes from 186 patients who underwent ICL implantation surgery. At 1 year after surgery, the central vault was measured using anterior segment optical coherence tomography. Preoperative anterior chamber depth, lens thickness, lens position (lens position = anterior chamber depth + 1/2 lens thickness), and vault were analyzed to investigate the effects of lens-related factors on postoperative vault. The mean vault was 513 ± 215 µm at 1 year after surgery. Vault was positively correlated with preoperative anterior chamber depth (r = 0.495, P lens position (r = 0.371, P lens thickness (r = -0.262, P lens position than eyes in the other two vault groups (which had vaults ≥ 250 µm) (P lens position less than 5.1 mm had greatly reduced vaults (P lens could have an important influence on postoperative vault. Eyes with a shallower anterior chamber and a forward lens position will have lower vaults. [J Refract Surg. 2017;33(8):519-523.]. Copyright 2017, SLACK Incorporated.

  14. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    DEFF Research Database (Denmark)

    Shin, K. W.; Andersen, Poul

    2015-01-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached...

  15. Improving the lens design and performance of a contemporary electromagnetic shock wave lithotripter

    Science.gov (United States)

    Neisius, Andreas; Smith, Nathan B.; Sankin, Georgy; Kuntz, Nicholas John; Madden, John Francis; Fovargue, Daniel E.; Mitran, Sorin; Lipkin, Michael Eric; Simmons, Walter Neal; Preminger, Glenn M.; Zhong, Pei

    2014-01-01

    The efficiency of shock wave lithotripsy (SWL), a noninvasive first-line therapy for millions of nephrolithiasis patients, has not improved substantially in the past two decades, especially in regard to stone clearance. Here, we report a new acoustic lens design for a contemporary electromagnetic (EM) shock wave lithotripter, based on recently acquired knowledge of the key lithotripter field characteristics that correlate with efficient and safe SWL. The new lens design addresses concomitantly three fundamental drawbacks in EM lithotripters, namely, narrow focal width, nonidealized pulse profile, and significant misalignment in acoustic focus and cavitation activities with the target stone at high output settings. Key design features and performance of the new lens were evaluated using model calculations and experimental measurements against the original lens under comparable acoustic pulse energy (E+) of 40 mJ. The −6-dB focal width of the new lens was enhanced from 7.4 to 11 mm at this energy level, and peak pressure (41 MPa) and maximum cavitation activity were both realigned to be within 5 mm of the lithotripter focus. Stone comminution produced by the new lens was either statistically improved or similar to that of the original lens under various in vitro test conditions and was significantly improved in vivo in a swine model (89% vs. 54%, P = 0.01), and tissue injury was minimal using a clinical treatment protocol. The general principle and associated techniques described in this work can be applied to design improvement of all EM lithotripters. PMID:24639497

  16. Effect of biweekly shoot tip harvests on the growth and yield of Georgia Jet sweet potato grown hydroponically

    Science.gov (United States)

    Ogbuehi, Cyriacus R.; Loretan, Phil A.; Bonsi, C. K.; Hill, Walter A.; Morris, Carlton E.; Biswas, P. K.; Mortley, Desmond G.

    1989-01-01

    Sweet potato shoot tips have been shown to be a nutritious green vegetable. A study was conducted to determine the effect of biweekly shoot tip harvests on the growth and yield of Georgia Jet sweet potato grown in the greenhouse using the nutrient film technique (NFT). The nutrient solution consisted of a modified half Hoagland solution. Biweekly shoot tip harvests, beginning 42 days after planting, provided substantial amounts of vegetable greens and did not affect the fresh and dry foliage weights or the storage root number and fresh and dry storage root weights at final harvest. The rates of anion and cation uptake were not affected by tip harvests.

  17. Plasmonic Colloidal Nanoantennas for Tip-Enhanced Raman Spectrocopy

    Science.gov (United States)

    Dill, Tyler J.

    Plasmonic nanoantennas that a support localized surface plasmon resonance (LSPR) are capable of confining visible light to subwavelength dimensions due to strong electromagnetic field enhancement at the probe tip. Nanoantenna enable optical methods such as tip-enhanced Raman spectroscopy (TERS), a technique that uses scanning probe microscopy tips to provide chemical information with nanoscale spatial resolution and single-molecule sensitivities. The LSPR supported by the probe tip is extremely sensitive to the nanoscale morphology of the nanoantenna. Control of nanoscale morphology is notoriously difficult to achieve, resulting in TERS probes with poor reproducibility. In my thesis, I demonstrate high-performance, predictable, and broadband nanospectroscopy probes that are fabricated by self-assembly. Shaped metal nanoparticles are organized into dense layers and deposited onto scanning probe tips. When coupled to a metal substrate, these probes support a strong optical resonance in the gap between the substrate and the probe, producing dramatic field enhancements. I show through experiment and electromagnetic modeling that close-packed but electrically isolated nanoparticles are electromagnetically coupled. Hybridized LSPRs supported by self-assembled nanoparticles with a broadband optical response, giving colloidal nanoantenna a high tolerance for geometric variation resulting from fabrication. I find that coupled nanoparticles act as a waveguide, transferring energy from many neighboring nanoparticles towards the active TERS apex. I also use surface-enhanced Raman spectroscopy (SERS) to characterize the effects of nanoparticle polydispersity and gap height on the Raman enhancement. These colloidal probes have consistently achieved dramatic Raman enhancements in the range of 108-109 with sub-50 nm spatial resolution. Furthermore, in contrast to other nanospectroscopy probes, these colloidal probes can be fabricated in a scalable fashion with a batch

  18. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, D. [Toshiba America Medical Systems (United States)

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  19. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  20. TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

    International Nuclear Information System (INIS)

    Zhang, D.

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  1. TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

    International Nuclear Information System (INIS)

    2015-01-01

    awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice

  2. Hand hygiene prior to contact lens handling is problematical.

    Science.gov (United States)

    McMonnies, Charles W

    2012-04-01

    To establish guidelines for contact lens wearers' hand hygiene practices which achieve a balance between minimising risk of infection and reasonable expectations on the ability of patients to follow them. Evidence has been obtained from publications via PubMed, Advanced Medline Search, Cochrane Reviews, Google Scholar and using the key words hand hygiene, washing and contact lens. Guidelines for effective hand washing and the bother involved vary according to the level of hygiene required. High levels of non-compliance with hand hygiene practices, even among healthcare workers, gives an indication of how important the level of bother involved when following guidelines can be in contributing to non-compliance. Better patient education to improve hand washing techniques as well as patient attitudes toward hand hygiene are needed to reduce high non-compliance levels. Better hand hygiene techniques and higher frequency of their application give the prospect of reduced risk of infection and of any discomfort that arises from increased lens and ocular bioburden. In order that adoption rates might be maximised, the guidelines which have been distilled from this review attempt to strike a balance between technique redundancy and the associated higher levels of hygiene achieved and the possibility that the perception of too much bother involved could reduce participation rates. The guidelines have been expanded by the inclusion of suggested explanatory information in the expectation that helping patients to understand why the recommendations are made will have the effect of increasing their adoption. Copyright © 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. Crack Tip Mechanics in Distortion Gradient Plasticity

    DEFF Research Database (Denmark)

    Fuentes-Alonso, Sandra; Martínez Pañeda, Emilio

    2017-01-01

    Gradient Plasticity (DGP), the influence on crack tip mechanics of DGP's distinguishing features that entail superior modelling capabilities has not been investigated yet. In this work crack tip fields are thoroughly examined by implementing the higher order theory of DGP in an implicit finite element...

  4. Jagged gives endothelial tip cells an edge.

    Science.gov (United States)

    Suchting, Steven; Eichmann, Anne

    2009-06-12

    Sprouting blood vessels have tip cells that lead and stalk cells that follow. Benedito et al. (2009) now show that competition between endothelial cells for the tip position is regulated by glycosylation of Notch receptors and by the opposing actions of the Notch ligands Jagged1 and Delta-like 4.

  5. Twelve Tips for Effective Electronic Presentation.

    Science.gov (United States)

    Crosby, Joy

    1994-01-01

    Offers 12 tips for effective electronic presentation. This article is intended for readers who may be considering using electronic presentation for the first time. Offers reasons for its popularity and occasions when it may be used. The tips offer assistance in the design and presentation of electronic material. (LZ)

  6. Role of Aquaporin 0 in lens biomechanics

    International Nuclear Information System (INIS)

    Sindhu Kumari, S.; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G.; Menon, Anil G.; Mathias, Richard T.; Varadaraj, Kulandaiappan

    2015-01-01

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5 −/− ), AQP0 KO (heterozygous KO: AQP0 +/− ; homozygous KO: AQP0 −/− ; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0 +/− lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to

  7. Algorithm design of liquid lens inspection system

    Science.gov (United States)

    Hsieh, Lu-Lin; Wang, Chun-Chieh

    2008-08-01

    In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.

  8. Freeform lens design for LED collimating illumination.

    Science.gov (United States)

    Chen, Jin-Jia; Wang, Te-Yuan; Huang, Kuang-Lung; Liu, Te-Shu; Tsai, Ming-Da; Lin, Chin-Tang

    2012-05-07

    We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performance of the lens, a prototype of the collimator lens is also made, and an optical efficiency of 90.3% with a beam angle of 4.75 deg is measured.

  9. Effects of External Hydrogen on Hydrogen Transportation and Distribution Around the Fatigue Crack Tip in Type 304 Stainless Steel

    Science.gov (United States)

    Chen, Xingyang; Zhou, Chengshuang; Cai, Xiao; Zheng, Jinyang; Zhang, Lin

    2017-10-01

    The effects of external hydrogen on hydrogen transportation and distribution around the fatigue crack tip in type 304 stainless steel were investigated by using hydrogen microprint technique (HMT) and thermal desorption spectrometry. HMT results show that some silver particles induced by hydrogen release are located near the fatigue crack and more silver particles are concentrated around the crack tip, which indicates that hydrogen accumulates in the vicinity of the crack tip during the crack growth in hydrogen gas environment. Along with the crack propagation, strain-induced α' martensite forms around the crack tip and promotes hydrogen invasion into the matrix, which will cause the crack initiation and propagation at the austenite/ α' martensite interface. In addition, the hydrogen content in the vicinity of the crack tip is higher than that at the crack edge far away from the crack tip, which is related to the stress state and strain-induced α' martensite.

  10. Study of Tip-loss Using an Inverse 3D Navier-Stokes Method

    DEFF Research Database (Denmark)

    Mikkelsen, Robert; Sørensen, Jens Nørkær; Shen, Wen Zhong

    2003-01-01

    the 3D Navier-Stokes equations combined with the actuator line technique where blade loading is applied using an inverse method. The numerical simulations shows that the method captures the tip-correction when comparing with the theories of Prandtl and Goldstein, however, the accuracy of the obtained...... results reveal that further refinements still is needed. Keywords: Tip-loss; Actuator line; 3D Navier-Stokes methods....

  11. Effects of transjugular intrahepatic portosystemic shunt (TIPS) on blood volume distribution in patients with cirrhosis

    DEFF Research Database (Denmark)

    Busk, Troels M; Bendtsen, Flemming; Henriksen, Jens H

    2017-01-01

    increased (+22%, prestores central hypovolaemia......BACKGROUND: Cirrhosis is accompanied by portal hypertension with splanchnic and systemic arterial vasodilation, and central hypovolaemia. A transjugular intrahepatic portosystemic shunt (TIPS) alleviates portal hypertension, but also causes major haemodynamic changes. AIMS: To investigate effects...... catheterization. Central and arterial blood volume (CBV) and cardiac output (CO) were determined with indicator dilution technique. RESULTS: After TIPS, the thoracic blood volume increased (+10.4% of total blood volume (TBV), p

  12. Changes in lens stiffness due to capsular opacification in accommodative lens refilling

    NARCIS (Netherlands)

    Nibourg, Lisanne M.; Sharma, Prashant K.; van Kooten, Theo G.; Koopmans, Steven A.

    Accommodation may be restored to presbyopic lenses by refilling the lens capsular bag with a soft polymer. After this accommodative lens refilling prevention of capsular opacification is a requirement, since capsular opacification leads to a decreased clarity of the refilled lens. It has been

  13. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  14. Early warning of climate tipping points

    Science.gov (United States)

    Lenton, Timothy M.

    2011-07-01

    A climate 'tipping point' occurs when a small change in forcing triggers a strongly nonlinear response in the internal dynamics of part of the climate system, qualitatively changing its future state. Human-induced climate change could push several large-scale 'tipping elements' past a tipping point. Candidates include irreversible melt of the Greenland ice sheet, dieback of the Amazon rainforest and shift of the West African monsoon. Recent assessments give an increased probability of future tipping events, and the corresponding impacts are estimated to be large, making them significant risks. Recent work shows that early warning of an approaching climate tipping point is possible in principle, and could have considerable value in reducing the risk that they pose.

  15. Photoshop Elements 10 Top 100 Simplified Tips and Tricks

    CERN Document Server

    Sheppard, Rob

    2011-01-01

    A visual guide to getting the most out of Photoshop Elements 10 If you understand the basics of Photoshop Elements, you'll love this collection of 100 must-know tips and tricks. Two-page tutorials, full-color screen shots, and step-by-step instructions make it easy to see and follow the directions, helping you to get the very most from this top-selling image-editing software. This guide catches you up on Photoshop Elements 10, covers features you may not have known about, and alerts you to a slew of cool effects and techniques. Explains techniques, best practices, and creative ways to transfor

  16. Estimation of plasma ion saturation current and reduced tip arcing using Langmuir probe harmonics.

    Science.gov (United States)

    Boedo, J A; Rudakov, D L

    2017-03-01

    We present a method to calculate the ion saturation current, I sat , for Langmuir probes at high frequency (>100 kHz) using the harmonics technique and we compare that to a direct measurement of I sat . It is noted that the I sat estimation can be made directly by the ratio of harmonic amplitudes, without explicitly calculating T e . We also demonstrate that since the probe tips using the harmonic method are oscillating near the floating potential, drawing little power, this method reduces tip heating and arcing and allows plasma density measurements at a plasma power flux that would cause continuously biased tips to arc. A multi-probe array is used, with two spatially separated tips employing the harmonics technique and measuring the amplitude of at least two harmonics per tip. A third tip, located between the other two, measures the ion saturation current directly. We compare the measured and calculated ion saturation currents for a variety of plasma conditions and demonstrate the validity of the technique and its use in reducing arcs.

  17. Lens design and local minima

    International Nuclear Information System (INIS)

    Brixner, B.

    1981-01-01

    The widespread belief that local minima exist in the least squares lens-design error function is not confirmed by the Los Alamos Scientific Laboratory (LASL) optimization program. LASL finds the optimum-mimimum region, which is characterized by small parameter gradients of similar size, small performance improvement per iteration, and many designs that give similar performance. Local minima and unique prescriptions have not been found in many-parameter problems. The reason for these absences is that image errors caused by a change in one parameter can be compensated by changes in the remaining parameters. False local minima have been found, and four cases are discussed

  18. Transcaval TIPS in patients with failed revision of occluded previous TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Chang Kyu; Kim, Yong Joo; Shin, Tae Beom; Park, Hyo Yong; Kim, Tae Hun; Kang, Duk Sik [Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2001-12-01

    To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  19. The tipping point: A mathematical model for the profit-driven abandonment of restaurant tipping

    Science.gov (United States)

    Clifton, Sara M.; Herbers, Eileen; Chen, Jack; Abrams, Daniel M.

    2018-02-01

    The custom of voluntarily tipping for services rendered has gone in and out of fashion in America since its introduction in the 19th century. Restaurant owners that ban tipping in their establishments often claim that social justice drives their decisions, but we show that rational profit-maximization may also justify the decisions. Here, we propose a conceptual model of restaurant competition for staff and customers, and we show that there exists a critical conventional tip rate at which restaurant owners should eliminate tipping to maximize profits. Because the conventional tip rate has been increasing steadily for the last several decades, our model suggests that restaurant owners may abandon tipping en masse when that critical tip rate is reached.

  20. DotLens smartphone microscopy for biological and biomedical applications (Conference Presentation)

    Science.gov (United States)

    Sung, Yu-Lung; Zhao, Fusheng; Shih, Wei-Chuan

    2017-02-01

    Recent advances in inkjet-printed optics have created a new class of lens fabrication technique. Lenses with a tunable geometry, magnification, and focal length can be fabricated by dispensing controlled amounts of liquid polymer onto a heated surface. This fabrication technique is highly cost-effective, and can achieve optically smooth surface finish. Dubbed DotLens, a single of which weighs less than 50 mg and occupies a volume less than 50 μL. DotLens can be attached onto any smartphone camera akin to a contact lens, and enable smartphones to obtain image resolution as fine as 1 µm. The surface curvature modifies the optical path of light to the image sensor, and enables the camera to focus as close as 2 mm. This enables microscopic imaging on a smartphone without any additional attachments, and has shown great potential in mobile point-of-care diagnostic systems, particularly for histology of tissue sections and cytology of blood cells. DotLens Smartphone Microscopy represents an innovative approach fundamentally different from other smartphone microscopes. In this paper, we describe the application and performance of DotLens smartphone microscopy in biological and biomedical research. In particular, we show recent results from images collected from pathology tissue slides with cancer features. In addition, we show performance in cytological analysis of blood smear. This tool has empowered Citizen Science investigators to collect microscopic images from various interesting objects.

  1. Two-laser thermal-lens determination of phosphorus in silicon

    International Nuclear Information System (INIS)

    Grishko, V.I.; Gol'dshtein, M.M.; Grishko, V.P.; Yudelevich, I.G.

    1986-01-01

    Laser thermal-lens spectrophotometry is a high-sensitivity method of measuring absorptivity, where the signal is the relative intensity change at the beam center after passage through the medium, which absorbs at the laser wavelength. The two-lens method is discussed here which employs a high-power laser to induce the lens, while the absorptivity is measured from the intensity change in the beam from a continous wave low-power test laser at a wavelength different from that for the inducing one. This paper uses two-laser thermal-lens techniques to determine phosphorus in silicon. Phosphorus is determined as the ionic association of molybdophosphoric acid with auramine

  2. Development of a Fresnel lens for cold neutrons based on neutron refractive optics

    International Nuclear Information System (INIS)

    Oku, T.; Morita, S.; Moriyasu, S.; Yamagata, Y.; Ohmori, H.; Takizawa, Y.; Shimizu, H.M.; Hirota, T.; Kiyanagi, Y.; Ino, T.; Furusaka, M.; Suzuki, J.

    2001-01-01

    We have developed compound refractive lenses (CRLs) for cold neutrons, which are made of vitreous silica and have an effective potential of (90.1-2.7x10 -4 i) neV. In the case of compound refractive optics, neutron absorption by the material deteriorates lens performance. Thus, to prevent an increase in neutron absorption with increasing beam size, we have developed Fresnel lenses using the electrolytic in-process dressing grinding technique. The lens characteristics were carefully investigated with experimental and numerical simulation studies. The lenses functioned as a neutron focusing lens, and the focal length of 14 m was obtained with a 44-element series of the Fresnel lenses for 10 A neutrons. Moreover, good neutron transmission of 0.65 for 15 A neutrons was obtained due to the shape effect. According to comprehensive analysis of the obtained results, it is possible to realize a CRL for practical use by choosing a suitable lens shape and material

  3. Ultrathin Alvarez lens system actuated by artificial muscles.

    Science.gov (United States)

    Petsch, S; Grewe, A; Köbele, L; Sinzinger, S; Zappe, H

    2016-04-01

    A key feature of Alvarez lenses is that they may be tuned in focal length using lateral rather than axial translation, thus reducing the overall length of a focus-tunable optical system. Nevertheless the bulk of classical microsystems actuators limits further miniaturization. We present here a new, ultrathin focus-tunable Alvarez lens fabricated using molding techniques and actuated using liquid crystal elastomer (LCE) artificial muscle actuators. The large deformation generated by the LCE actuators permits the integration of the actuators in-plane with the mechanical and optical system and thus reduces the device thickness to only 1.6 mm. Movement of the Alvarez lens pair of 178 μm results in a focal length change of 3.3 mm, based on an initial focal length of 28.4 mm. This design is of considerable interest for realization of ultraflat focus-tunable and zoom systems.

  4. Beam manipulating by metal–anisotropic–metal plasmonic lens

    International Nuclear Information System (INIS)

    Bahramipanah, M; Abrishamian, M S; Mirtaheri, S A

    2012-01-01

    Embedding anisotropic media in the slit region of a plasmonic nano-optic lens is proposed as a new method of actively modulating the output beam. The focal length can be controlled easily by exposing the plasmonic nano-optic lens to a constant external electric field. The physical principle of this phenomenon is evaluated from the phase of surface plasmon polaritons (SPPs) in the slits and the electro-optical effect of liquid crystals. Our numerical simulations using the finite-difference time-domain (FDTD) technique reveal that a large tuning range of the focal length up to 545 nm at the first communication window can be achieved. The special feature of the proposed structure gives it an opportunity to be used as an efficient element in ultrahigh nano-scale integrated photonic circuits for miniaturization and tuning purposes. (paper)

  5. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  6. Tips & Techniques: Storytelling with Puppets and Props. [Videotape].

    Science.gov (United States)

    2002

    On this 20-minute videotape, two accomplished storytellers share their expertise on using puppets and props to enhance the art of storytelling. Schroeder Cherry uses several types of puppets to tell his educational story about the Underground Railroad, while Karen Quinn-Wisniewski entertains her audience of young children with classic fables,…

  7. Tips, tricks and techniques in practicing OR - a different twist!

    Directory of Open Access Journals (Sweden)

    H.W. Ittmann

    2014-01-01

    Full Text Available This paper is a personal account of marketing and selling Operations Research (OR in South Africa. The author reflects on this activity that has occupied him over the past ten to fifteen years. The traditional marketing mix is possibly not ideal for selling a consulting service such as OR. The author shows how he used ingredients such as able people, physical evidence and process in selling the services of the group he represented. The main elements of being successful are: one or more success stories, credibility, a network of people (potential clients, quality staff, a sense of urgency within the group and a recognition that the client is always king.

  8. Cylindrical vector beams of light from an electrically excited plasmonic lens

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Shuiyan, E-mail: shuiyan.cao@u-psud.fr; Le Moal, Eric; Boer-Duchemin, Elizabeth; Dujardin, Gérald [Institut des Sciences Moléculaires d' Orsay, CNRS—Université Paris-Sud (UMR 8214), Orsay (France); Drezet, Aurélien; Huant, Serge [Université Grenoble Alpes, Inst. NEEL, F-38000 Grenoble (France); CNRS, Inst. NEEL, F-38042 Grenoble (France)

    2014-09-15

    The production of cylindrical vector beams from a low-energy, electric, microscale light source is demonstrated both experimentally and theoretically. This is achieved by combining a “plasmonic lens” with the ability to locally and electrically excite propagating surface plasmons on gold films. The plasmonic lens consists of concentric circular subwavelength slits that are etched in a thick gold film. The local excitation arises from the inelastic tunneling of electrons from the tip of a scanning tunneling microscope. We report on the emission of radially polarized beams with an angular divergence of less than ±4°.

  9. Tipping device for large components

    International Nuclear Information System (INIS)

    Guigon, J.P.; Beraudier, D.

    1984-01-01

    For large components machining as components of a pressurized water reactor, it is necessary to have means allowing to present them in a position determined with regard to the machine tool used. The aim of the invention is a tipping device which consists of a base resting on the ground, a support-table mounted on this base, moving in rotation with the aid of at least a pivot joint of which axis is horizontal and parallel to the table and a gear pivot allowing to get a very good precision for the orientation of the piece and a very good stability whatever the orientation may be. The output shaft pinion of the base meshes with a gear wheel segment fixed to the table structure. Safety straps fasten the table structure to the base, as they are secured by horizontal pins. The toe pins run in straight slot holes incorporated in base jaws. The table rotation may be controlled by a spring-loaded braking mechanism which acts on the pivot axis and can be released by a hydraulic jack. The hydraulic pressure is used to prevent motor operation, unless the brakes have been released [fr

  10. Tipping Points, Great and Small

    Science.gov (United States)

    Morrison, Foster

    2010-12-01

    The Forum by Jordan et al. [2010] addressed environmental problems of various scales in great detail, but getting the critical message through to the formulators of public policies requires going back to basics, namely, that exponential growth (of a population, an economy, or most anything else) is not sustainable. When have you heard any politician or economist from anywhere across the ideological spectrum say anything other than that more growth is essential? There is no need for computer models to demonstrate “limits to growth,” as was done in the 1960s. Of course, as one seeks more details, the complexity of modeling will rapidly outstrip the capabilities of both observation and computing. This is common with nonlinear systems, even simple ones. Thus, identifying all possible “tipping points,” as suggested by Jordan et al. [2010], and then stopping just short of them, is impractical if not impossible. The main thing needed to avoid environmental disasters is a bit of common sense.

  11. Correction of 157-nm lens based on phase ring aberration extraction method

    Science.gov (United States)

    Meute, Jeff; Rich, Georgia K.; Conley, Will; Smith, Bruce W.; Zavyalova, Lena V.; Cashmore, Julian S.; Ashworth, Dominic; Webb, James E.; Rich, Lisa

    2004-05-01

    Early manufacture and use of 157nm high NA lenses has presented significant challenges including: intrinsic birefringence correction, control of optical surface contamination, and the use of relatively unproven materials, coatings, and metrology. Many of these issues were addressed during the manufacture and use of International SEMATECH"s 0.85NA lens. Most significantly, we were the first to employ 157nm phase measurement interferometry (PMI) and birefringence modeling software for lens optimization. These efforts yielded significant wavefront improvement and produced one of the best wavefront-corrected 157nm lenses to date. After applying the best practices to the manufacture of the lens, we still had to overcome the difficulties of integrating the lens into the tool platform at International SEMATECH instead of at the supplier facility. After lens integration, alignment, and field optimization were complete, conventional lithography and phase ring aberration extraction techniques were used to characterize system performance. These techniques suggested a wavefront error of approximately 0.05 waves RMS--much larger than the 0.03 waves RMS predicted by 157nm PMI. In-situ wavefront correction was planned for in the early stages of this project to mitigate risks introduced by the use of development materials and techniques and field integration of the lens. In this publication, we document the development and use of a phase ring aberration extraction method for characterizing imaging performance and a technique for correcting aberrations with the addition of an optical compensation plate. Imaging results before and after the lens correction are presented and differences between actual and predicted results are discussed.

  12. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  13. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  14. The keys to successful TIPS in patients with portal vein thrombosis and cavernous transformation.

    Science.gov (United States)

    Lombardo, S; Espejo, J J; Pérez-Montilla, M E; Zurera, L J; González-Galilea, Á

    Portal vein thrombosis is a common complication in patients with cirrhosis. Anticoagulation involves a high risk of bleeding secondary to portal hypertension, so placing transjugular intrahepatic portosystemic shunts (TIPS) has become an alternative treatment for portal vein thrombosis. Three strategies for TIPS placement have been reported: 1) portal recanalization and conventional implantation of the TIPS through the jugular vein; 2) portal recanalization through percutaneous transhepatic/transsplenic) access; and (3) insertion of the TIPS between the suprahepatic vein and a periportal collateral vessel without portal recanalization. We describe different materials that can be used as fluoroscopic targets for the TIPS needle and for portal recanalization. This article aims to show the success of TIPS implantation using different combinations of the techniques listed above, which is a good treatment alternative in these patients whose clinical condition makes them difficult to manage, and to show that portal vein thrombosis/cavernous transformation should not be considered a contraindication for TIPS. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  16. Analysis of a Thin Optical Lens Model

    Science.gov (United States)

    Ivchenko, Vladimir V.

    2011-01-01

    In this article a thin optical lens model is considered. It is shown that the limits of its applicability are determined not only by the ratio between the thickness of the lens and the modules of the radii of curvature, but above all its geometric type. We have derived the analytical criteria for the applicability of the model for different types…

  17. Mathematical Lens: How Much Can You Bench?

    Science.gov (United States)

    Bolognese, Chris A.

    2013-01-01

    "How Much Can You Bench?" appears in the "Mathematical Lens" section of "Mathematics Teacher." "Mathematical Lens" uses photographs as a springboard for mathematical inquiry and appears in every issue of "Mathematics Teacher." This month the mathematics behind the photograph includes finding areas…

  18. Plasma Lens for Muon and Neutrino Beams

    International Nuclear Information System (INIS)

    Kahn, S.A.; Korenev, S.; Bishai, M.; Diwan, M.; Gallardo, J.C.; Hershcovitch, A.; Johnson, B.M.

    2008-01-01

    The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-energy lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma for optimum focusing. The plasma lens is immersed in an additional solenoid magnetic field to facilitate the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. Plasma lenses have the additional advantage of negligible pion absorption and scattering by the lens material and reduced neutrino contamination during anti-neutrino running. Results of particle simulations using plasma lens will be presented

  19. Radiocarbon Dating of the Human Eye Lens Crystallines Reveal Proteins without Carbon Turnover throughout Life

    Science.gov (United States)

    Lynnerup, Niels; Kjeldsen, Henrik; Heegaard, Steffen; Jacobsen, Christina; Heinemeier, Jan

    2008-01-01

    Background Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule) completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its 14C content from the atmospheric carbon dioxide. The 14C content of the lens proteins thus reflects the atmospheric content of 14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the 14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric 14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. Methodology/Principal Findings Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. Conclusions/Significance Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the 14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA). Potential targets may be nervous tissues in terms of senile or pre-senile degradation, as well as other highly

  20. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life.

    Directory of Open Access Journals (Sweden)

    Niels Lynnerup

    Full Text Available BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14C content from the atmospheric carbon dioxide. The (14C content of the lens proteins thus reflects the atmospheric content of (14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the (14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. CONCLUSIONS/SIGNIFICANCE: Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA. Potential targets may be nervous tissues in terms of senile or pre

  1. TEM observations of crack tip: cavity interactions

    International Nuclear Information System (INIS)

    Horton, J.A.; Ohr, S.M.; Jesser, W.A.

    1981-01-01

    Crack tip-cavity interactions have been studied by performing room temperature deformation experiments in a transmission electron microscope on ion-irradiated type 316 stainless steel with small helium containing cavities. Slip dislocations emitted from a crack tip cut, sheared, and thereby elongated cavities without a volume enlargement. As the crack tip approached, a cavity volume enlargement occurred. Instead of the cavities continuing to enlarge until they touch, the walls between the cavities fractured. Fracture surface dimples do not correlate in size or density with these enlarged cavities

  2. LensEnt2: Maximum-entropy weak lens reconstruction

    Science.gov (United States)

    Marshall, P. J.; Hobson, M. P.; Gull, S. F.; Bridle, S. L.

    2013-08-01

    LensEnt2 is a maximum entropy reconstructor of weak lensing mass maps. The method takes each galaxy shape as an independent estimator of the reduced shear field and incorporates an intrinsic smoothness, determined by Bayesian methods, into the reconstruction. The uncertainties from both the intrinsic distribution of galaxy shapes and galaxy shape estimation are carried through to the final mass reconstruction, and the mass within arbitrarily shaped apertures are calculated with corresponding uncertainties. The input is a galaxy ellipticity catalog with each measured galaxy shape treated as a noisy tracer of the reduced shear field, which is inferred on a fine pixel grid assuming positivity, and smoothness on scales of w arcsec where w is an input parameter. The ICF width w can be chosen by computing the evidence for it.

  3. Adverse impact of multileaf collimator field shaping on lens dose in children with acute leukemia receiving cranial irradiation

    International Nuclear Information System (INIS)

    Kalapurakal, John A.; Sathiaseelan, Vythialingam; Bista, Tomasz C.; Marymont, Maryanne H.

    2000-01-01

    Purpose: This study was designed to investigate the impact of multileaf collimator (MLC) on lens dose in children with leukemia undergoing cranial irradiation. Methods and Materials: This is a prospective study utilizing three common cranial irradiation techniques. Technique A uses a half-beam, nondivergent radiation field. Technique B has the anterior divergent field edge at the lateral bony canthus. Technique C is similar to B, but with a field collimator angle. Thermoluminescent dosimeter (TLD) lens dose measurements were obtained in children and phantom with all three techniques. Results: Seventeen children were studied. Lens dose measurements were obtained in 14 children with technique A using MLC and blocks. In 7 of 14 children, dose measurements were obtained with MLC only. One child was treated with technique B and 2 children were treated with C, with MLC ± blocks. In all 3 techniques, with MLC alone, the lens dose increased by 64%, 119%, and 72%, respectively. Similar results were obtained in phantom. Conclusion: This study demonstrates that independent of irradiation technique, additional custom blocking is required to maximally protect the lens with MLC shaped fields. This is due to the lack of conformity between MLC and the desired field edge at the lateral bony canthus

  4. Effects of the Tongue-in-Groove Maneuver on Nasal Tip Rotation.

    Science.gov (United States)

    Antunes, Marcelo B; Quatela, Vito C

    2018-03-27

    Changes in nasal tip rotation is a very common maneuver performed during rhinoplasty. Among the many techniques used to achieve this goal is the tongue-in-groove (TIG). This study addresses the long-term effect of the TIG on the nasal tip rotation 1 year after rhinoplasty. The authors prospectively identified patients who were submitted to a rhinoplasty with a TIG maneuver over a period of 1 year. The angle of rotation was measured along the nostril axis angle. The data was analyzed using the t-test and a linear regression model. Seventeen patients were included. The average preoperative tip rotation was 93.95° (SD, 3.12°). Immediate postoperative tip rotation averaged 114.47° (SD, 3.79°). At the 1-year follow-up appointment, the tip rotation averaged 106.55° (SD, 3.54°). There was a significant loss of rotation at the 1-year postoperative visit (pTIG is a more dependable technique than the ones that rely on healing and contraction to obtain rotation. Our data demonstrated a significant loss of rotation during the first year. This suggests that the surgeon needs to slightly overcorrect the tip rotation to account for this loss.

  5. Outcomes of torsional microcoaxial phacoemulsification performed by 12-degree and 22-degree bent tips.

    Science.gov (United States)

    Helvacioglu, Firat; Yeter, Celal; Tunc, Zeki; Sencan, Sadik

    2013-08-01

    To compare the safety and efficacy of Ozil Intelligent Phaco torsional microcoaxial phacoemulsification surgeries performed with 12-degree and 22-degree bent tips using the Infiniti Vision System. Maltepe University School of Medicine Department of Ophthalmology, Istanbul, Turkey. Comparative case series. Eyes were assigned to 2.2 mm microcoaxial phacoemulsification using the torsional mode with a 22-degree bent tip (Group 1) or a 12-degree bent tip (Group 2). The primary outcome measures were ultrasound time (UST), cumulative dissipated energy (CDE), longitudinal and torsional ultrasound (US) amplitudes, mean surgical time, mean volume of balanced salt solution used, and surgical complications. Both groups included 45 eyes. The mean UST, CDE, longitudinal US amplitude, and torsional US amplitude were 65 seconds ± 27.23 (SD), 11.53 ± 6.99, 0.22 ± 0.26, and 42.86 ± 15.64, respectively, in Group 1 and 84 ± 45.04 seconds, 16.68 ± 10.66, 0.48 ± 0.68, and 46.27 ± 14.74, respectively, in Group 2. The mean UST, CDE, and longitudinal amplitudes were significantly lower in Group 1 (P=.003, P=.008, and P=.022, respectively). The mean volume of balanced salt solution was 73.33 ± 28.58 cc in Group 1 and 82.08 ± 26.21 cc in Group 2 (P=.134). Torsional phacoemulsification performed with 22-degree bent tips provided more effective lens removal than 12-degree bent tips, with a lower UST and CDE. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Sleep Tips: 7 Steps to Better Sleep

    Science.gov (United States)

    ... turn every night. Consider simple tips for better sleep, from setting a sleep schedule to including physical activity in your daily ... factors that can interfere with a good night's sleep — from work stress and family responsibilities to unexpected ...

  7. Diabetes Prevention: 5 Tips for Taking Control

    Science.gov (United States)

    ... Consider the latest diabetes prevention tips from the American Diabetes Association. There are many benefits to regular physical activity. ... if diabetes testing is appropriate for you. The American Diabetes Association recommends blood glucose screening if: You're age ...

  8. Tips to Help You Get Active

    Science.gov (United States)

    ... A Step in the Right Direction Tips to Help You Get Active View or Print All Sections ... and quality of life. Being more active may help you manage your weight. Starting Physical Activity Healthy ...

  9. Brain Injury Safety Tips and Prevention

    Science.gov (United States)

    ... submit" name="commit" type="submit" value="Submit" /> Brain Injury Safety Tips and Prevention Recommend on Facebook ... not grass or dirt. More HEADS UP Video: Brain Injury Safety and Prevention frame support disabled and/ ...

  10. Tips for Teens with Diabetes: About Diabetes

    Science.gov (United States)

    National Diabetes Education Program (NDEP), 2010

    2010-01-01

    Diabetes is a serious disease. It means that one's blood glucose, also called blood sugar, is too high. Having too much glucose in a person's blood is not healthy. This paper offers tips for managing diabetes.

  11. Daily Tips for Good Oral Hygiene

    Science.gov (United States)

    ... this article Daily Tips for Good Oral Hygiene Bacteria can live in your mouth in the form of plaque, causing cavities and gingivitis, which can lead to periodontal (gum) disease. In order to keep your mouth ...

  12. Impetigo: Tips for Treatment and Prevention

    Science.gov (United States)

    ... DO Videos Contact Close ‹ Back to Healthy Living Impetigo: Tips for Treatment and Prevention The symptoms of ... to other parts of their bodies. Causes of Impetigo Impetigo usually affects preschool and school-aged children, ...

  13. Can't sleep? Try these tips

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000853.htm Can't sleep? Try these tips To use the ... you get the rest you need. What you can do Some people have trouble falling asleep. Others ...

  14. Four Medication Safety Tips for Older Adults

    Science.gov (United States)

    ... Products For Consumers Home For Consumers Consumer Updates 4 Medication Safety Tips for Older Adults Share Tweet ... you are experiencing could be due to medications. 4. Review Medications with Your Health Care Provider Ideally, ...

  15. Essential Outdoor Sun Safety Tips for Winter

    Science.gov (United States)

    ... Weekend Warriors expand/collapse Vitamin D Essential Outdoor Sun Safety Tips for Winter Winter sports enthusiasts are ... skiing! Be Mindful of Time Spent in the Sun, Regardless of the Season If possible, ski early ...

  16. 6 Tips: IBS and Complementary Health Practices

    Science.gov (United States)

    ... health practice for IBS, here are 6 tips: Hypnotherapy (hypnosis). This practice involves the power of suggestion by ... IBS. According to reviews of the scientific literature, hypnotherapy may be a helpful treatment for managing IBS ...

  17. Compressor airfoil tip clearance optimization system

    Science.gov (United States)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  18. Tips for Older Dietary Supplement Users

    Science.gov (United States)

    ... Information for Consumers Tips for Older Dietary Supplement Users Share Tweet Linkedin Pin it More sharing options ... site are provided as a service to our users and do not represent FDA endorsement of these ...

  19. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  20. Liquid-intake flow around the tip of butterfly proboscis.

    Science.gov (United States)

    Lee, Sang Joon; Lee, Seung Chul; Kim, Bo Heum

    2014-05-07

    Butterflies drink liquid through a slender proboscis using a large pressure gradient induced by the systaltic operation of a muscular pump inside their head. Although the proboscis is a naturally well-designed coiled micro conduit for liquid uptake and deployment, it has been regarded as a simple straw connected to the muscular pump. There are few studies on the transport of liquid food in the proboscis of a liquid-feeding butterfly. To understand the liquid-feeding mechanism in the proboscis of butterflies, the intake flow around the tip of the proboscis was investigated in detail. In this study, the intake flow was quantitatively visualized using a micro-PIV (particle image velocimetry) velocity field measurement technique. As a result, the liquid-feeding process consists of an intake phase, an ejection phase and a rest phase. When butterflies drink pooled liquid, the liquid is not sucked into the apical tip of the proboscis, but into the dorsal linkage aligned longitudinally along the proboscis. To analyze main characteristics of the intake flow around a butterfly proboscis, a theoretical model was established by assuming that liquid is sucked into a line sink whose suction rate linearly decreases proximally. In addition, the intake flow around the tip of a female mosquito׳s proboscis which has a distinct terminal opening was also visualized and modeled for comparison. The present results would be helpful to understand the liquid-feeding mechanism of a butterfly. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Low power femtosecond tip-based nanofabrication with advanced control

    Science.gov (United States)

    Liu, Jiangbo; Guo, Zhixiong; Zou, Qingze

    2018-02-01

    In this paper, we propose an approach to enable the use of low power femtosecond laser in tip-based nanofabrication (TBN) without thermal damage. One major challenge in laser-assisted TBN is in maintaining precision control of the tip-surface positioning throughout the fabrication process. An advanced iterative learning control technique is exploited to overcome this challenge in achieving high-quality patterning of arbitrary shape on a metal surface. The experimental results are analyzed to understand the ablation mechanism involved. Specifically, the near-field radiation enhancement is examined via the surface-enhanced Raman scattering effect, and it was revealed the near-field enhanced plasma-mediated ablation. Moreover, silicon nitride tip is utilized to alleviate the adverse thermal damage. Experiment results including line patterns fabricated under different writing speeds and an "R" pattern are presented. The fabrication quality with regard to the line width, depth, and uniformity is characterized to demonstrate the efficacy of the proposed approach.

  2. Gonioscopy-assisted Transluminal Trabeculotomy (GATT): Thermal Suture Modification With a Dye-stained Rounded Tip.

    Science.gov (United States)

    Grover, Davinder S; Fellman, Ronald L

    2016-06-01

    To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. One patient was used as an example for this technique. Technique report. The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.

  3. Lessons learned: wrong intraocular lens.

    Science.gov (United States)

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  5. Superconducting phase transition in STM tips

    Energy Technology Data Exchange (ETDEWEB)

    Eltschka, Matthias; Jaeck, Berthold; Assig, Maximilian; Etzkorn, Markus; Ast, Christian R. [Max Planck Institute for Solid State Research, Stuttgart (Germany); Kern, Klaus [Max Planck Institute for Solid State Research, Stuttgart (Germany); Ecole Polytechnique Federale de Lausanne (Switzerland)

    2015-07-01

    The superconducting properties of systems with dimensions comparable to the London penetration depth considerably differ from macroscopic systems. We have studied the superconducting phase transition of vanadium STM tips in external magnetic fields. Employing Maki's theory we extract the superconducting parameters such as the gap or the Zeeman splitting from differential conductance spectra. While the Zeeman splitting follows the theoretical description of a system with s=1/2 and g=2, the superconducting gaps as well as the critical fields depend on the specific tip. For a better understanding of the experimental results, we solve a one dimensional Usadel equation modeling the superconducting tip as a cone with the opening angle α in an external magnetic field. We find that only a small region at the apex of the tip is superconducting in high magnetic fields and that the order of the phase transition is directly determined by α. Further, the spectral broadening increases with α indicating an intrinsic broadening mechanism due to the conical shape of the tip. Comparing these calculations to our experimental results reveals the order of the superconducting phase transition of the STM tips.

  6. The spectral sensitivity of the lens eyes of a box jellyfish, Tripedalia cystophora (Conant)

    DEFF Research Database (Denmark)

    Coates, Melissa M; Garm, Anders; Theobald, Jamie C

    2006-01-01

    Box jellyfish, or cubomedusae (class Cubozoa), are unique among the Cnidaria in possessing lens eyes similar in morphology to those of vertebrates and cephalopods. Although these eyes were described over 100 years ago, there has been no work done on their electrophysiological responses to light. ...... result from the presence of a single receptor type containing a single opsin. The peak sensitivity is to blue-green light. Visual pigment template fits indicate a vitamin A-1 based opsin with peak sensitivity near 500 nm for both eye types.......Box jellyfish, or cubomedusae (class Cubozoa), are unique among the Cnidaria in possessing lens eyes similar in morphology to those of vertebrates and cephalopods. Although these eyes were described over 100 years ago, there has been no work done on their electrophysiological responses to light. We...... used an electroretinogram (ERG) technique to measure spectral sensitivity of the lens eyes of the Caribbean species Tripedalia cystophora. The cubomedusae have two kinds of lens eyes, the lower and upper lens eyes. We found that both lens eye types have similar spectral sensitivities, which likely...

  7. Precision lens assembly with alignment turning system

    Science.gov (United States)

    Ho, Cheng-Fang; Huang, Chien-Yao; Lin, Yi-Hao; Kuo, Hui-Jean; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Chen, Fong-Zhi

    2017-10-01

    The poker chip assembly with high precision lens barrels is widely applied to ultra-high performance optical system. ITRC applies the poker chip assembly technology to the high numerical aperture objective lenses and lithography projection lenses because of its high efficiency assembly process. In order to achieve high precision lens cell for poker chip assembly, an alignment turning system (ATS) is developed. The ATS includes measurement, alignment and turning modules. The measurement module is equipped with a non-contact displacement sensor (NCDS) and an autocollimator (ACM). The NCDS and ACM are used to measure centration errors of the top and the bottom surface of a lens respectively; then the amount of adjustment of displacement and tilt with respect to the rotational axis of the turning machine for the alignment module can be determined. After measurement, alignment and turning processes on the ATS, the centration error of a lens cell with 200 mm in diameter can be controlled within 10 arcsec. Furthermore, a poker chip assembly lens cell with three sub-cells is demonstrated, each sub-cells are measured and accomplished with alignment and turning processes. The lens assembly test for five times by each three technicians; the average transmission centration error of assembly lens is 12.45 arcsec. The results show that ATS can achieve high assembly efficiency for precision optical systems.

  8. Chemical composition of felt-tip pen inks.

    Science.gov (United States)

    Germinario, Giulia; Garrappa, Silvia; D'Ambrosio, Valeria; van der Werf, Inez Dorothé; Sabbatini, Luigia

    2018-01-01

    Felt-tip pens are frequently used for the realization of sketches, drawings, architectural projects, and other technical designs. The formulations of these inks are usually rather complex and may be associated to those of modern paint materials where, next to the binding medium and pigments/dyes, solvents, fillers, emulsifiers, antioxidants, plasticizers, light stabilizers, biocides, and so on are commonly added. Felt-tip pen inks are extremely sensitive to degradation and especially exposure to light may cause chromatic changes and fading. In this study, we report on the complete chemical characterization of modern felt-tip pen inks that are commercially available and commonly used for the realization of artworks. Three brands of felt-tip pens (Faber-Castell, Edding, and Stabilo) were investigated with complementary analytical techniques such as thin-layer chromatography (TLC), VIS-reflectance spectroscopy, μ-Raman spectroscopy, surface-enhanced Raman spectroscopy (SERS), pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), GC-MS, and Fourier transform infrared (FTIR) spectroscopy. The use of TLC proved to be very powerful in the study of complex mixtures of synthetic dyes. First derivatives of the reflectance spectra acquired on the TLC spots were useful in the preliminary identification of the dye, followed by Raman spectroscopy and SERS, which allowed for the unambiguous determination of the chemical composition of the pigments (phthalocyanines, dioxazines, and azo pigments) and dyes (azo dyes, triarylmethanes, xanthenes). FTIR spectroscopy was used especially for the detection of additives, as well as for confirming the nature of solvents and dyes/pigments. Finally, (Py-)GC-MS data provided information on the binders (styrene-acrylic resins, plant gums), solvents, and additives, as well as on pigments and dyes.

  9. Effect of chronic smoking on lens nucleus as assessed by Pentacam HR lens densitometry in young adults.

    Science.gov (United States)

    Pekel, Gökhan; Cetin, Ebru Nevin; Acer, Semra; Yagci, Ramazan; Altintas, Seher; Ongun, Gülin Tugba

    2014-06-01

    To evaluate the effects of chronic tobacco smoking on lens nucleus by Pentacam HR lens densitometry (LD) in young adults. Prospective cross-sectional case series. Thirty subjects (23 M, 7 F) who were chronic cigarette smokers (≥10 cigarettes/day for at least 2 years) (group 1) and another 30 subjects (23 M, 7 F) who did not smoke (group 2), were included in this study. The patients were matched for age and sex between the groups. The exclusion criteria were any history of ocular surgery, any systemic disorders and any ocular diseases except for mild refractive disorders. Lens densitometry measurements were done with the Pentacam HR (Oculus, Wetzlar, Germany). The Schirmer test and pachymetry measurements were also performed. Mean age of the patients for both groups was 28.90 ± 8.20 years (range: 18-40 years). Mean lens densitometry (LD) measurements of Group 1 (chronic cigarette smoking group) were higher than those of Group 2 (control group) in all LD techniques; however only mean "peak" LD measurements showed a statistically significant difference between these two groups (Group 1: 8.67 ± 0.61, Group 2: 8.44 ± 0.70, p = 0.04). The mean Schirmer test value was 12.43 ± 5.60 mm in Group 1 and 13.00 ± 4.26 mm in Group 2 (p = 0.55). The mean central corneal thickness (CCT) value was 564.23 ± 34.61 µm in Group 1 and 550.47 ± 32.94 µm in Group 2 (p = 0.03). The Pentacam HR LD seems to be an important option for the evaluation of lens nucleus in young adults, because it gives objective and quantitative data. Although chronic smoking increases lens nucleus density in young adults, the effect is not statistically significant when compared with the control group.

  10. Sutureless Intrascleral Fixated Intraocular Lens Implantation.

    Science.gov (United States)

    Karadag, Remzi; Celik, Haci Ugur; Bayramlar, Huseyin; Rapuano, Christopher J

    2016-08-01

    To review sutureless intrascleral intraocular lens (IOL) fixation methods. Review of published literature. Sutureless intrascleral IOL fixation methods are newer and have been developed to eliminate the suture-related complications of sutured scleral fixation methods such as suture-induced inflammation or infection and IOL dislocation or subluxation due to suture degradation or suture breakage. Sutureless intrascleral fixation methods aim for intrascleral haptic fixation to achieve stability of the IOL. Various methods of sutureless scleral fixation have been described. Using a needle, a blade, or a trochar, sclerostomies are created in all techniques for intraocular access. Some surgeons prefer to create scleral tunnels, whereas others use scleral flaps for scleral fixation of haptics. The stability of IOLs is attained by the scar tissue formed around the haptics. Short-term results of these new methods are acceptable; studies including more cases with longer follow-up are needed to determine their long-term success. [J Cataract Refract Surg. 2016;32(9):586-597.]. Copyright 2016, SLACK Incorporated.

  11. Design of a hyperbolic microwave metallic lens

    International Nuclear Information System (INIS)

    Uckan, T.

    1979-12-01

    Due to problems caused by multiple reflections in the cavity walls of the EBT fusion research device, the use of a horn becomes important for the directivity of waves in the millimetric range. An ordinary dielectric lens cannot be used because of plasma-wall interactions. Microwave metallic lenses, designed to focus the energy into a plane wave, can improve the directivity considerably. By implementing a 70-GHz standard-gain horn with a delay-type hyperbolic lens, which consists of a solid metallic disk with a number of equal size small holes has indicated a gain of 15 dB over the no lens case

  12. Accelerating convergence in automatic lens design

    International Nuclear Information System (INIS)

    Brixner, B.

    1981-01-01

    Among the various factors that slow lens optimization-insufficient performance targets, the absence of a unique solution, false local minima, a poorly scaled change vector, failure to find the optimum damping number, and failure to equalize the parameter gradients-the importance of parameter gradient equalization has been insufficiently recognized. Gradients can be approximately equalized by scaling the lens to a suitable size while it is being optimized. For best results, the size of the damping number should also be optimized during each iteration. If these two procedures are followed, scaling the change vector is usually not crucial. To illustrate the importance of parameter equalization, a lens optimization is analyzed

  13. SIMION, Electrostatic Lens Analysis and Design

    International Nuclear Information System (INIS)

    Dahl, David A.

    2001-01-01

    1 - Description of program or function: SIMION is an electrostatic lens analysis and design program. In SIMION an electrostatic lens is defined as a two-dimensional electrostatic potential array containing both electrode and non-electrode points. The potential array is refined using over-relaxation methods allowing voltage contours and ion trajectories to be computed and plotted. Planar and cylindrical symmetry assumptions allow the two-dimensional fields to support three-dimensional ion trajectory calculations. In addition, the user has the option of writing simple programs which can among other actions control field scale factors, dynamically adjust electrodes, and define explicit three-dimensional field functions (e.g. a quadrupole) used in lieu of array fields in specified portions of the potential array. Magnetic fields can be specified for computing ion trajectories in many electrostatic and magnetic field environments. An interactive graphics interface that uses a high resolution color display and mouse allows the user to view electrodes, trajectories, and contours on the screen prior to plotting, and a memory zoom feature permits expansion of selected areas in the current view. The mouse can be operated to edit the potential array, initialize voltage gradients, or resize the potential array. 2 - Method of solution: SIMION is designed to model the electrostatic fields and forces created by a collection of shaped electrodes given certain symmetry assumptions. The electrostatic fields are modeled as boundary value problem solutions of a Laplace elliptical partial differential equation. A finite difference technique called dynamically self-adjusting over-relaxation is applied to the two-dimensional potential array of points representing electrode and non-electrode regions to obtain a best estimate of the voltages for those points within the array that depict non-electrode regions. A standard fourth-order Runge-Kutta method is used for numerical integration of

  14. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  15. 21 CFR 886.5844 - Prescription spectacle lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prescription spectacle lens. 886.5844 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5844 Prescription spectacle lens. (a) Identification. A prescription spectacle lens is a glass or plastic device that is a lens intended to be worn by...

  16. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...

  17. [Four surgical tips in the treatment of epicondylitis].

    Science.gov (United States)

    Jiménez, I; Marcos-García, A; Muratore-Moreno, G; Medina, J

    2016-01-01

    Lateral epicondylitis is a common injury in the population. Most patients improve with conservative treatment, but in a small percentage surgery is necessary. The aim of this study is to analyse the clinical results obtained by a «4 surgical tips» technique. This is a retrospective study of 35 operated elbows, with a mean follow-up of 5.3 years. In all cases epicondylar denervation, removal of the angiofibroblastic degeneration core, epicondylectomy, and release of posterior interosseous nerve, was performed. Each patient was evaluated using the Broberg and Morrey Rating System (BMRS), Mayo Elbow Performance Score (MEPS), Visual Analogue Scale (VAS), DASH questionnaire, and a survey of subjective assessment. BMRS mean score was 97.2 points, with 95.71 points with the MEPS. The mean decrease in VAS was 8.12 points, and the mean score on the DASH was 1.68 points. The results were rated as excellent or very good by 94.3% of patients. There was one recurrence, which resolved with further surgery. Two neuropraxia of the posterior interosseous nerve occurred, which completely recovered in 10 weeks. Using the «4 surgical tips» technique, clinical resolution of symptoms in 97.1% was achieved at the first operation. Therefore, it appears to be an effective, reproducible technique with few complications, in the surgical treatment of lateral epicondylitis resistant to conservative treatment. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  18. TIPS Evaluation Project Retrospective Study: Wave 1 and 2.

    Science.gov (United States)

    Hubbard, Susan M.; Mulvey, Kevin P.

    2003-01-01

    Measured substance abuse treatment professionals' knowledge, attitudes, and practices regarding the Treatment Improvement Protocol (TIP) series and the 28 TIPs. Results for 3,267 respondents in wave 1 and 1,028 in wave 2 indicate that almost half of all professionals were aware of the TIPs. Attitudes toward TIPs were positive, but professionals…

  19. Top tips from tree tops

    Science.gov (United States)

    Ornes, Stephen

    2018-04-01

    The ability of trees to cool by transporting water from their roots to the leaves has been known for centuries. But as Stephen Ornes discovers, the principles of transpiration are also inspiring innovative techniques to cool vehicles travelling at hypersonic speeds, where unwanted heat is a problem too

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast To learn more about how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist ...

  1. Proteomic and metabolomic analyses of soybean root tips under flooding stress.

    Science.gov (United States)

    Komatsu, Setsuko; Nakamura, Takuji; Sugimoto, Yurie; Sakamoto, Kazunori

    2014-01-01

    Flooding is one of the serious problems for soybean plants because it inhibits growth. Proteomic and metabolomic techniques were used to determine whether proteins and metabolites are altered in the root tips of soybeans under flooding stress. Two-day-old soybean plants were flooded for 2 days, and proteins and metabolites were extracted from root tips. Flooding-responsive proteins were identified using two-dimensional- or SDS-polyacrylamide gel electrophoresis- based proteomics techniques. Using both techniques, 172 proteins increased and 105 proteins decreased in abundance in the root tips of flood-stressed soybean. The abundance of methionine synthase, heat shock cognate protein, urease, and phosphoenol pyruvate carboxylase was significantly increased by flooding stress. Furthermore, 73 flooding-responsive metabolites were identified using capillary electrophoresis-mass spectrometry. The levels of gamma-aminobutyric acid, glycine, NADH2, and phosphoenol pyruvate were increased by flooding stress. Taken together, these results suggest that synthesis of phosphoenol pyruvate by way of oxaloacetate produced in the tricarboxylic acid cycle is activated in soybean root tips in response to flooding stress, and that flooding stress also leads to modulation of the urea cycle in the root tips.

  2. Tipping solutions: emerging 3D nano-fabrication/ -imaging technologies

    Directory of Open Access Journals (Sweden)

    Seniutinas Gediminas

    2017-06-01

    Full Text Available The evolution of optical microscopy from an imaging technique into a tool for materials modification and fabrication is now being repeated with other characterization techniques, including scanning electron microscopy (SEM, focused ion beam (FIB milling/imaging, and atomic force microscopy (AFM. Fabrication and in situ imaging of materials undergoing a three-dimensional (3D nano-structuring within a 1−100 nm resolution window is required for future manufacturing of devices. This level of precision is critically in enabling the cross-over between different device platforms (e.g. from electronics to micro-/nano-fluidics and/or photonics within future devices that will be interfacing with biological and molecular systems in a 3D fashion. Prospective trends in electron, ion, and nano-tip based fabrication techniques are presented.

  3. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  4. AutoLens: Automated Modeling of a Strong Lens's Light, Mass and Source

    Science.gov (United States)

    Nightingale, J. W.; Dye, S.; Massey, Richard J.

    2018-05-01

    This work presents AutoLens, the first entirely automated modeling suite for the analysis of galaxy-scale strong gravitational lenses. AutoLens simultaneously models the lens galaxy's light and mass whilst reconstructing the extended source galaxy on an adaptive pixel-grid. The method's approach to source-plane discretization is amorphous, adapting its clustering and regularization to the intrinsic properties of the lensed source. The lens's light is fitted using a superposition of Sersic functions, allowing AutoLens to cleanly deblend its light from the source. Single component mass models representing the lens's total mass density profile are demonstrated, which in conjunction with light modeling can detect central images using a centrally cored profile. Decomposed mass modeling is also shown, which can fully decouple a lens's light and dark matter and determine whether the two component are geometrically aligned. The complexity of the light and mass models are automatically chosen via Bayesian model comparison. These steps form AutoLens's automated analysis pipeline, such that all results in this work are generated without any user-intervention. This is rigorously tested on a large suite of simulated images, assessing its performance on a broad range of lens profiles, source morphologies and lensing geometries. The method's performance is excellent, with accurate light, mass and source profiles inferred for data sets representative of both existing Hubble imaging and future Euclid wide-field observations.

  5. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  6. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K; Sanada, C; Tsukino, M [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  7. Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.

    Science.gov (United States)

    Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P

    2004-01-01

    The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.

  8. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  9. Characteristics of soft X-ray lens

    International Nuclear Information System (INIS)

    Qin Yi

    2007-12-01

    A soft X-lens was devised with waveguide X-ray optics of total external reflection (TER). The lens consists of a stack of 1 387 TER waveguides with inner diameter of 0.45 mm and outer diameter of 0.60 mm. With the help of plasma sources of soft X-ray radiation, high density of pure soft X-ray radiation (without plasma expansion fragments) with broad-band spectral range can be obtained at the focus of the lens. As laser-plasma is considered, the radiation density of 1.3 x 10 5 W/cm 2 is obtained, the transmission coefficient is 18.6%, the ratio of the density at the focus with and without the lens is 1000 and the radiation capture is 28.9 degree. The density of 0.5 TW/cm 2 can be obtained as far as Qiang-Guang I facility is considered. (authors)

  10. Gravitational lens effect and pregalactic halo objects

    International Nuclear Information System (INIS)

    Bontz, R.J.

    1979-01-01

    The changes in flux, position, and size of a distant extended (galaxy, etc.) source that result from the gravitational lens action of a massive opaque object are discussed. The flux increase is described by a single function of two parameters. One of these parameters characterizes the strength of the gravitational lens, the other describes the alignment of source and lens object. This function also describes the relative intensity of the images formed by lens. ( A similar formalism is discussed by Bourassa et al. for a point source). The formalism is applied to the problem of the galactic halo. It appears that a massive (10 1 2 M/sub sun/) spherical halo surrounding the visible part of the galaxy is consistent with the observable properties of extragalactic sources

  11. Discovery of two new gravitation lens systems

    International Nuclear Information System (INIS)

    Guertler, J.

    1988-01-01

    The discovery of new quasar and radio galaxy double images produced by the gravitation lens effect is reported. The light deflecting galaxies acting as gravitational lenses could be made visible by means of image processing procedures

  12. A Plasma Lens for Magnetron Sputtering

    International Nuclear Information System (INIS)

    Anders, Andre; Brown, Jeff

    2010-01-01

    A plasma lens, consisting of a solenoid and potential-defining ring electrodes, has been placed between a magnetron and substrates to be coated. Photography reveals qualitative information on excitation, ionization, and the transport of plasma to the substrate.

  13. The discovery of a gravitational lens

    International Nuclear Information System (INIS)

    Chaffee, F.H. Jr.

    1981-01-01

    A recently discovered pair of quasars turns out to be not a pair at all but two images of a single quasar formed by a gravitational lens: an elliptical galaxy halfway between the quasar and our own galaxy. (orig.) [de

  14. EDEL: ENEA dosemeter for eye lens

    International Nuclear Information System (INIS)

    Ferrari, Paolo; Mariotti, Francesca; Campani, Lorenzo

    2016-01-01

    Since the publication of International Commission on Radiological Protection statement in 2011 on tissue reaction, eye lens radiation protection played an important role in exposed personnel dosimetry. For this reason, the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) Individual Monitoring Service decided to study a prototype to fulfil specific requests (e.g. for survey in interventional department and intercomparisons). On the basis of such preliminary investigation, a new eye lens dosemeter was developed. The new dosemeter, named EDEL (ENEA Dosemeter for Eye Lens), was characterised in terms of H p (3), the operational quantity related to eye lens monitoring. The investigation was performed experimentally and optimised using the Monte Carlo MCNP6 code. The new prototype was thought to fulfil two main requests: the reliability of the dosimetric data and the portability of the dosemeter itself. The new dosemeter will soon be supplied to the collaborating hospitals for workplace test measurements. (authors)

  15. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  16. Sectioning a luxated intraocular lens inside the vitreous cavity.

    Science.gov (United States)

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Role of Aquaporin 0 in lens biomechanics.

    Science.gov (United States)

    Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer

  18. RFQ pole-tip construction

    International Nuclear Information System (INIS)

    Crandall, K.R.; Stovall, J.E.

    1981-01-01

    The success of the radio-frequency quadrupole (RFQ) proof-of-principle (POP) tests conducted in 1980 at Los Alamos have essentially guaranteed that the RFQ linac will be used in many accelerator projects soon. Several RFQs are already under construction at Los Alamos, and we expect to be designing and machining the vanes for several RFQs to be built at other installations. The technique for machining the vanes for the POP RFQ was developed by Williams and Potter. While retaining their basic approach, we have modified their technique for generating the data required by the milling machine from the parameters defining the vane shapes. The objective of this exercise has been to develop a generalized fabrication procedure that could be used in commercial machine shops

  19. 2D mapping of plane stress crack-tip fields following an overload

    Directory of Open Access Journals (Sweden)

    P. J. Withers

    2015-07-01

    Full Text Available The evolution of crack-tip strain fields in a thin (plane stress compact tension sample following an overload (OL event has been studied using two different experimental techniques. Surface behaviour has been characterised by Digital Image Correlation (DIC, while the bulk behaviour has been characterised by means of synchrotron X-ray diffraction (XRD. The combination of both surface and bulk information allowed us to visualise the through-thickness evolution of the strain fields before the OL event, during the overload event, just after OL and at various stages after it. Unlike previous work, complete 2D maps of strains around the crack-tip were acquired at 60m spatial resolution by XRD. The DIC shows less crack opening after overload and the XRD a lower crack-tip peak stress after OL until the crack has grown past the compressive crack-tip residual stress introduced by the overload after which the behaviour returned to that for the baseline fatigue response. While the peak crack-tip stress is supressed by the compressive residual stress, the crack-tip stress field changes over each cycle are nevertheless the same for all Kmax cycles except at OL.

  20. Removal of artificial dental calculus by use of conventional and diamond ultrasound tips.

    Directory of Open Access Journals (Sweden)

    Roberto Carlos Mourão Pinho

    2017-04-01

    Full Text Available Introduction: Periodontal disease is considered a public health problem and may lead to serious complications as the general health of patient. The main therapeutic procedure is scaling and root planing, which can be performed by a variety of techniques and instruments Objective:The aim of the present study was to evaluate the removal of calculus, produced artificially, by using a conventional ultrasonic tip and a diamond – CVD tip. Method: The calculus was produced with artificial sawdust and glue-based cyanoacrylate and distributed in twenty areas also standardized on two plates of acrylic resin (chemical activated, holding 10 samples per plate. Standards / samples were divided by lot into two simple groups, being A (treated with conventional tip and B (treated with CVD tip. Results:The treatment in Group A, promoted an average area of 20.48 ± 4.20 mm2 free of artificial calculus which is significantly higher (p <0.05 than the area removed in Group B (15.37 ± 5.29 mm2. Conclusion:The results showed that the conventional tip presented higher results than CVD tip for efficacy in the removal of calculus.