WorldWideScience

Sample records for tip leakage flow

  1. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  2. Characteristics of tip-leakage flow in an axial fan

    Science.gov (United States)

    Park, Keuntae; Choi, Haecheon; Choi, Seokho; Sa, Yongcheol

    2014-11-01

    An axial fan with a shroud generates complicated vortical structures by the interaction of the axial flow with the fan blades and shroud near the blade tips. Large eddy simulation (LES) is performed for flow through a forward-swept axial fan, operating at the design condition of Re = 547,000 based on the radius of blade tip and the tip velocity. A dynamic global model (Lee et al. 2010) is used for a subgrid-scale model, and an immersed boundary method in a non-inertial reference frame (Kim & Choi 2006) is adopted for the present simulation. It is found that two vortical structures are formed near the blade tip: the main tip leakage vortex (TLV) and the auxiliary TLV. The main TLV is initiated near the leading edge, develops downstream, and impinges on the pressure surface of the next blade, where the pressure fluctuations and turbulence intensity become high. On the other hand, the auxiliary TLV is initiated at the aft part of the blade but is relatively weak such that it merges with the main TLV. Supported by the KISTI Supercomputing Center (KSC-2014-C2-014).

  3. An Experimental Characterization of Tip Leakage Flows and Corresponding Effects on Multistage Compressor Performance

    Science.gov (United States)

    Berdanier, Reid Adam

    The effect of rotor tip clearances in turbomachinery applications has been a primary research interest for nearly 80 years. Over that time, studies have shown increased tip clearance in axial flow compressors typically has a detrimental effect on overall pressure rise capability, isentropic efficiency, and stall margin. With modern engine designs trending toward decreased core sizes to increase propulsive efficiency (by increasing bypass ratio) or additional compression stages to increase thermal efficiency by increasing the overall pressure ratio, blade heights in the rear stages of the high pressure compressor are expected to decrease. These rear stages typically feature smaller blade aspect ratios, for which endwall flows are more important, and the rotor tip clearance height represents a larger fraction of blade span. As a result, data sets collected with large relative rotor tip clearance heights are necessary to facilitate these future small core design goals. This research seeks to characterize rotor tip leakage flows for three tip clearance heights in the Purdue three-stage axial compressor facility (1.5%, 3.0%, and 4.0% as a percentage of overall annulus height). The multistage environment of this compressor provides the unique opportunity to examine tip leakage flow effects due to stage matching, stator-rotor interactions, and rotor-rotor interactions. The important tip leakage flow effects which develop as a result of these interactions are absent for previous studies which have been conducted using single-stage machines or isolated rotors. A series of compressor performance maps comprise points at four corrected speeds for each of the three rotor tip clearance heights. Steady total pressure and total temperature measurements highlight the effects of tip leakage flows on radial profiles and wake shapes throughout the compressor. These data also evaluate tip clearance effects on efficiency, stall margin, and peak pressure rise capability. An emphasis of

  4. Effect of Relative Movement between the Shroud and Blade on Tip Leakage Flow Characteristics

    Directory of Open Access Journals (Sweden)

    Xiaochun Wang

    2017-10-01

    Full Text Available An experimental and numerical investigation into the tip leakage flow of a turbine rotor is carried out using a particle image velocimetry (PIV system and the commercial software ANSYS CFX 14.0. The specimen used in this work is a typical GE-E3 model with a new squealer tip design. The experimental data are used to create a turbulence model and numerical strategy. Through the validated turbulence model and numerical strategy, simulations are carried out to compare the characteristics of the tip leakage flow in three cases: (1 the blade is rotating, but the shroud is stationary, which is the real status of turbine rotor operation; (2 the blade is stationary, but the shroud moves, to simulate their relative movement; (3 the blade is stationary, and the shroud is also stationary, this is a simplified case, but has been widely used in the experiments on rotor tip leakage flow. Detailed analysis of the flow phenomena shows that the second case is a reasonable alternative approach to simulate the real state. However, the flow patterns in the third case exhibit some evident differences from the real status. These differences are caused by the inaccurate viscous force arising from the stationary blade and shroud. In this work, a modification method for the experiments conducted in the third case is firstly proposed, which is realized through adding an imaginary roughness at the shroud wall to be close to the real viscous effect, and to thereby reduce the deviation of the experiment from the real case. According to the results calculated by ANSYS CFX, the flow structure in the modification case is very close to the real status. Besides, this modification case is an easy and cheap way to simulate the real tip leakage flow.

  5. Study on tip leakage vortex cavitating flows using a visualization method

    Science.gov (United States)

    Zhao, Yu; Jiang, Yutong; Cao, Xiaolong; Wang, Guoyu

    2018-01-01

    Experimental investigations of unsteady cavitating flows in a hydrofoil tip leakage region with different gap sizes are conducted to highlight the development of gap cavitation. The experiments were taken in a closed cavitation tunnel, during which high-speed camera had been used to capture the cavitation patterns. A new visualization method based on image processing was developed to capture time-dependent cavitation patterns. The results show that the visualization method can effectively capture the cavitation patterns in the tip region, including both the attached cavity in the gap and the tip leakage vortex (TLV) cavity near the trailing edge. Moreover, with the decrease of cavitation number, the TLV cavity develops from a rapid onset-growth-collapse process to a continuous process, and extends both upstream and downstream. The attached cavity in the gap develops gradually stretching beyond the gap and combines with the vortex cavity to form the triangle cavitating region. Furthermore, the influences of gap size on the cavitation are also discussed. The gap size has a great influence on the loss across the gap, and hence the locations of the inception attached cavity. Besides, inception locations and extending direction of the TLV cavity with different gap sizes also differ. The TLV in the case with τ = 0.061 is more likely to be jet-like compared with that in the case with τ = 0.024, and the gap size has a great influence on the TLV strength.

  6. Effects of the inlet boundary layer thickness on the flow in an axial compressor (I) : hub corner stall and tip leakage flow

    International Nuclear Information System (INIS)

    Choi, Min Suk; Baek, Je Hyun; Park, Jun Young

    2005-01-01

    A three-dimensional computation was conducted to understand effects of the inlet boundary layer thickness on the internal flow in a low-speed axial compressor operating at the design condition(φ=85%) and near stall condition(φ=65%). At the design condition, the flows in the axial compressor show, independent of the inlet boundary layer thickness, similar characteristics such as the pressure distribution, size of the hub corner-stall, tip leakage flow trajectory, limiting streamlines on the blade suction surface, etc. However, as the load is increased, the hub corner-stall grows to make a large separation region at the junction of the hub and suction surface for the inlet condition with thick boundary layers at the hub and casing. Moreover, the tip leakage flow is more vortical than that observed in case of the thin inlet boundary layer and has the critical point where the trajectory of the tip leakage flow is abruptly turned into the downstream. For the inlet condition with thin boundary layers, the hub corner-stall is diminished so it is indistinguishable from the wake. The tip leakage flow leans to the leading edge more than at the design condition but has no critical point. In addition to these, the severe reverse flow, induced by both boundary layer on the blade surface and the tip leakage flow, can be found to act as the blockage of flows near the casing, resulting in heavy loss

  7. Numerical simulation of tip leakage vortex effect on hydrogen-combustion flow around 3D turbine blade

    Science.gov (United States)

    Miyama, Naoto; Inaba, Kazuaki; Yamamoto, Makoto

    2008-06-01

    In these years, a lot of environmental problems such as air pollution and exhaustion of fossil fuels have been discussed intensively. In our laboratory, a hydrogen-fueled propulsion system has been researched as an alternative to conventional systems. A hydrogen-fueled propulsion system is expected to have higher power, lighter weight and lower emissions. However, for the practical use, there exist many problems that must be overcome. Considering these backgrounds, jet engines with hydrogen-fueled combustion within a turbine blade passage have been studied. Although some studies have been made on injecting and burning hydrogen fuel from a stator surface, little is known about the interaction between a tip leakage vortex near the suction side of a rotor tip and hydrogen-fueled combustion. The purpose of this study is to clarify the influence of the tip leakage vortex on the characteristics of the 3-dimensional flow field with hydrogen-fueled combustion within a turbine blade passage. Reynolds-averaged compressible Navier-Stokes equations are solved with incorporating a k-ɛ turbulence and a reduced chemical mechanism models. Using the computational results, the 3-dimensional turbulent flow field with chemical reactions is numerically visualized, and the three-dimensional turbulent flow fields with hydrogen combustion and the structure of the tip leakage vortex are investigated.

  8. Investigation of Turbulent Tip Leakage Vortex in an Axial Water Jet Pump with Large Eddy Simulation

    Science.gov (United States)

    Hah, Chunill; Katz, Joseph

    2012-01-01

    Detailed steady and unsteady numerical studies were performed to investigate tip clearance flow in an axial water jet pump. The primary objective is to understand physics of unsteady tip clearance flow, unsteady tip leakage vortex, and cavitation inception in an axial water jet pump. Steady pressure field and resulting steady tip leakage vortex from a steady flow analysis do not seem to explain measured cavitation inception correctly. The measured flow field near the tip is unsteady and measured cavitation inception is highly transient. Flow visualization with cavitation bubbles shows that the leakage vortex is oscillating significantly and many intermittent vortex ropes are present between the suction side of the blade and the tip leakage core vortex. Although the flow field is highly transient, the overall flow structure is stable and a characteristic frequency seems to exist. To capture relevant flow physics as much as possible, a Reynolds-averaged Navier-Stokes (RANS) calculation and a Large Eddy Simulation (LES) were applied for the current investigation. The present study reveals that several vortices from the tip leakage vortex system cross the tip gap of the adjacent blade periodically. Sudden changes in local pressure field inside tip gap due to these vortices create vortex ropes. The instantaneous pressure filed inside the tip gap is drastically different from that of the steady flow simulation. Unsteady flow simulation which can calculate unsteady vortex motion is necessary to calculate cavitation inception accurately even at design flow condition in such a water jet pump.

  9. Study of the leakage field of magnetic force microscopy thin-film tips using electron holography

    NARCIS (Netherlands)

    Frost, B.G.; van Hulst, N.F.; Lunedei, E.; Matteucci, G.; Rikkers, E.

    1996-01-01

    Electron holography is applied for the study of the leakage field of thin-film ferromagnetic tips used as probes in magnetic force microscopy. We used commercially available pyramidal tips covered o­n o­ne face with a thin NiCo film, which were then placed in a high external magnetic field directed

  10. Investigation of the Shear Flow Effect and Tip Clearance on a Low Speed Axial Flow Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Mahesh Varpe

    2013-01-01

    Full Text Available This paper explores the effect of inlet shear flow on the tip leakage flow in an axial flow compressor cascade. A flow with a high shear rate is generated in the test section of an open circuit cascade wind tunnel by using a combination of screens with a prescribed solidity. It is observed that a stable shear flow of shear rate 1.33 is possible and has a gradual decay rate until 15 times the height of the shear flow generator downstream. The computational results obtained agree well with the available experimental data on the baseline configuration. The detailed numerical analysis shows that the tip clearance improves the blade loading near the tip through the promotion of favorable incidence by the tip leakage flow. The tip clearance shifts the centre of pressure on the blade surface towards the tip. It, however, has no effect on the distribution of end wall loss and deviation angle along the span up to 60% from the hub. In the presence of a shear inflow, the end wall effects are considerable. On the other hand, with a shear inflow, the effects of tip leakage flow are observed to be partly suppressed. The shear flow reduces the tip leakage losses substantially in terms of kinetic energy associated with it.

  11. Tip gap flow characteristics in a turbine cascade equipped with pressure-side partial squealer rims

    International Nuclear Information System (INIS)

    Lee, Sang Woo; Lee, Seong Eun

    2014-01-01

    Highlights: • The tip gap flow over pressure-side (PS) squealer tips is investigated. • A schematic tip gap flow model for the PS squealer tip is suggested. • The PS squealer tip has lower aerodynamic loss than the plane tip. - Abstract: Tip gap flow characteristics and aerodynamic loss generations in a turbine cascade equipped with pressure-side partial squealer rims have been investigated with the variation of its rim height-to-span ratio (h p /s) for a tip gap height of h/s = 1.36%. The results show that the tip gap flow is characterized not only by the incoming leakage flow over the pressure-side squealer rim but also by the upstream flow intrusion behind the rim. The incoming leakage flow tends to decelerate through the divergent tip gap flow channel and can hardly reach the blade suction side upstream of the mid-chord, due to the interaction with the upstream flow intrusion as well as due to the flow deceleration. A tip gap flow model has been proposed for h p /s = 3.75%, and the effect of h p /s on the tip surface flow is discussed in detail. With increasing h p /s, the total-pressure loss coefficient mass-averaged all over the present measurement plane decreases steeply, has a minimum value for h p /s = 1.88%, and then increases gradually. Its maximum reduction with respect to the plane tip result is evaluated to be 11.6%, which is found not better than that in the cavity squealer tip case

  12. Tip-leakage cavitation in the clearance of a 2D hydrofoil with fillets: high-speed visualization and PIV/PTV measurements

    Science.gov (United States)

    Zapryagaev, Ivan I.; Timoshevskiy, Mikhail V.; Pervunin, Konstantin S.

    2017-09-01

    Tip-clearance cavitation is one of the most aggressive forms of cavitation as it can cause surface erosion of hydraulic machinery elements and, as a result, their fatigue damage and disturb designed operating conditions. At present, the literature lacks for detailed experimental data on the inception and development of this type of cavitation at various flow conditions. In the paper, a tip-leakage cavitation occurring in the clearance between an end face of a 2D hydrofoil (a scaled-down model of guide vanes (GV) of a Francis turbine) and a transparent wall of the test section was studied. The experiments were carried out for different cavitating regimes on the cavitation number and two attack angles of 3° and 9°, with the gap size (tip clearance width) varied in the range from 0.4 to 0.8 mm. In order to determine the cavitation inception conditions and investigate the dynamics of the tip-leakage cavitation, a high-speed visualization was applied. A modified PIV/PTV technique with a diverging laser beam instead of a laser light sheet was used to measure the mean velocity distributions within the gap. It was shown that the cavitation pattern on the suction side of the GV model impacts the dynamics of the leakage flow in the gap but does not affect the sheet cavity formed close to the foil leading edge in the clearance as well as its size and dynamics. When the gap size is increased, the tip-leakage cavitation initiates at higher cavitation numbers or, in other words, conditions for the cavitation occurrence become more favorable.

  13. Investigation of Performance and Rotor Tip Flow Field in a Low Speed Research Compressor with Circumferential Groove Casing Treatment at Varying Tip Clearance

    Directory of Open Access Journals (Sweden)

    Matthias Rolfes

    2017-01-01

    Full Text Available Experimental investigations in a single-stage low speed axial research compressor are presented. The influence of four different rotor tip clearances on the overall compressor performance and on the rotor tip flow field is investigated in configurations with and without circumferential groove casing treatments. Piezo-resistive pressure transducers are used to capture the unsteady flow field in the rotor tip region. The investigated casing groove is effectively working at the three largest investigated tip clearance sizes. The largest achieved operating range increase by the groove is 6.9%. The groove can delay the upstream movement of the flow interface between leakage flow and main flow and thus increase the stable operating range. Rotating instabilities are shown to exist at large tip clearance sizes in throttled operating conditions. Their amplitudes can be damped by the casing groove. No modal activities could be detected in the current single-stage compressor build.

  14. Experimental and computational investigation of the tip clearance flow in a transonic axial compressor rotor

    Energy Technology Data Exchange (ETDEWEB)

    Suder, K.L. [NASA-Lewis Research Center, Cleveland, OH (United States); Celestina, M.L. [Sverdrup Technology Inc., Cleveland, OH (United States). Lewis Research Center Group

    1996-04-01

    Experimental and computational techniques are used to investigate tip clearance flows in a transonic axial compressor rotor at design and part-speed conditions. Laser anemometer data acquired in the endwall region are presented for operating conditions near peak efficiency and near stall at 100 percent design speed and at near peak efficiency at 60 percent design speed. The role of the passage shock/leakage vortex interaction at design speed, the radial influence of the tip clearance flow extends to 20 times the physical tip clearance height. At part speed, in the absence of the shock, the radial extent is only five times the tip clearance height. Both measurements and analysis indicate that under part-speed operating conditions a second vortex, which does not originate from the tip leakage flow, forms in the end-wall region within the blade passage and exits the passage near midpitch. Mixing of the leakage vortex with the primary flow downstream of the rotor at both design and part-speed conditions is also discussed.

  15. Experimental and Computational Investigation of the Tip Clearance Flow in a Transonic Axial Compressor Rotor

    Science.gov (United States)

    Suder, Kenneth L.; Celestina, Mark L.

    1995-01-01

    Experimental and computational techniques are used to investigate tip clearance flows in a transonic axial compressor rotor at design and part speed conditions. Laser anemometer data acquired in the endwall region are presented for operating conditions near peak efficiency and near stall at 100% design speed and at near peak efficiency at 60% design speed. The role of the passage shock/leakage vortex interaction in generating endwall blockage is discussed. As a result of the shock/vortex interaction at design speed, the radial influence of the tip clearance flow extends to 20 times the physical tip clearance height. At part speed, in the absence of the shock, the radial extent is only 5 times the tip clearance height. Both measurements and analysis indicate that under part-speed operating conditions a second vortex, which does not originate from the tip leakage flow, forms in the endwall region within the blade passage and exits the passage near midpitch. Mixing of the leakage vortex with primary flow downstream of the rotor at both design and part speed conditions is also discussed.

  16. Review of leakage-flow-induced vibrations of reactor components

    International Nuclear Information System (INIS)

    Mulcahy, T.M.

    1983-05-01

    The primary-coolant flow paths of a reactor system are usually subject to close scrutiny in a design review to identify potential flow-induced vibration sources. However, secondary-flow paths through narrow gaps in component supports, which parallel the primary-flow path, occasionally are the excitation source for significant vibrations even though the secondary-flow rates are orders of magnitude smaller than the primary-flow rate. These so-called leakage flow problems are reviewed here to identify design features and excitation sources that should be avoided. Also, design rules of thumb are formulated that can be employed to guide a design, but quantitative prediction of component response is found to require scale-model testing

  17. Ducted fan inlet/exit and rotor tip flow improvements for vertical lift systems

    Science.gov (United States)

    Akturk, Ali

    The current research utilized experimental and computational techniques in 5" and 22" diameter ducted fan test systems that have been custom designed and manufactured. Qualitative investigation of flow around the ducted fan was also performed using smoke flow visualizations. Quantitative measurements consisted of 2D and 3D velocity measurements using planar and Stereoscopic Particle Image Velocimetry (PIV and SPIV), high resolution total pressure measurements using Kiel total pressure probes and real time six-component force and torque measurements. The computational techniques used in this thesis included a recently developed radial equilibrium based rotor model(REBRM) and a three dimensional Reynolds-Averaged Navier Stokes (RANS) based CFD model. A radial equilibrium based rotor model (REBRM) developed by the author was effectively integrated into a three-dimensional RANS based computational system. The PIV measurements and computational flow predictions using (REBRM) near the fan inlet plane were in a good agreement at hover and forward flight conditions. The aerodynamic modifications resulting from the fan inlet flow distortions in forward flight regime were clearly captured in 2D PIV results. High resolution total pressure measurements at the downstream of the fan rotor showed that tip leakage, rotor hub separation, and passage flow related total pressure losses were dominant in hover condition. However, the losses were dramatically increased in forward flight because of inlet lip separation and distortion. A novel ducted fan inlet flow conditioning concept named "Double Ducted Fan" (DDF) was developed. The (DDF) concept has a potential to significantly improve the performance and controllability of VTOL UAVs and many other ducted fan based vertical lift systems. The new concept that will significantly reduce the inlet lip separation related performance penalties used a secondary stationary duct system to control "inlet lip separation" occurring especially at

  18. Understanding of the Interaction between Clearance Leakage Flow and Main Passage Flow in a VGT Turbine

    Directory of Open Access Journals (Sweden)

    Ben Zhao

    2015-02-01

    Full Text Available The clearance flow between the nozzle and endwall in a variable geometry turbine (VGT has been numerically investigated to understand the clearance effect on the VGT performance and internal flow. It was found that the flow rate through turbine increases but the turbine efficiency decreases with height of clearance. Detailed flow field analyses indicated that most of the efficiency loss resulting from the leakage flow occurs at the upstream of the rotor area, that is, in the nozzle endwall clearance and between the nozzle vanes. There are two main mechanisms associated with this efficiency loss. One is due to the formation of the local vortex flow structure between the clearance flow and the main flow. The other is due to the impact of the clearance flow on the main flow after the nozzle throat. This impact reduces the span of shockwave with increased shockwave magnitude by changing the trajectory of the main flow.

  19. Film cooling effects on the tip flow characteristics of a gas turbine blade

    Directory of Open Access Journals (Sweden)

    Jin Wang

    2015-03-01

    Full Text Available An experimental investigation of the tip flow characteristics between a gas turbine blade tip and the shroud was conducted by a pressure-test system and a particle image velocimetry (PIV system. A three-times scaled profile of the GE-E3 blade with five film cooling holes was used as specimen. The effects on flow characteristics by the rim width and the groove depth of the squealer tip were revealed. The rim widths were (a 0.9%, (b 2.1%, and (c 3.0% of the axial chord, and the groove depths were (a 2.8%, (b 4.8%, and (c 10% of the blade span. Several pressure taps on the top plate above the blades were connected to pressure gauges. By a CCD camera the PIV system recorded the velocity field around the leading edge zone including the five cooling holes. The flow distributions both in the tip clearance and in the passage were revealed, and the influence of the inlet velocity was determined. In this work, the tip flow characteristics with and without film cooling were investigated. The effects of different global blowing ratios of M=0.5, 1.0, 1.3 and 2.5 were established. It was found that decreasing the rim width resulted in a lower mass flow rate of the leakage flow, and the pressure distributions from the leading edge to the trailing edge showed a linearly increasing trend. It was also found that if the inlet velocity was less than 1.5 m/s, the flow field in the passage far away from the suction side appeared as a stagnation zone.

  20. A study on two phase flows of linear compressors for the prediction of refrigerant leakage

    International Nuclear Information System (INIS)

    Hwang, Il Sun; Lee, Young Lim; Oh, Won Sik; Park, Kyeong Bae

    2015-01-01

    Usage of linear compressors is on the rise due to their high efficiency. In this paper, leakage of a linear compressor has been studied through numerical analysis and experiments. First, nitrogen leakage for a stagnant piston with fixed cylinder pressure as well as for a moving piston with fixed cylinder pressure was analyzed to verify the validity of the two-phase flow analysis model. Next, refrigerant leakage of a linear compressor in operation was finally predicted through 3-dimensional unsteady, two phase flow CFD (Computational fluid dynamics). According to the research results, the numerical analyses for the fixed cylinder pressure models were in good agreement with the experimental results. The refrigerant leakage of the linear compressor in operation mainly occurred through the oil exit and the leakage became negligible after about 0.4s following operation where the leakage became lower than 2.0x10 -4 kg/s.

  1. Numerical and experimental study of the leakage flow in guide vanes with different hydrofoils

    Directory of Open Access Journals (Sweden)

    Sailesh Chitrakar

    2017-07-01

    Full Text Available Clearance gaps between guide vanes and cover plates of Francis turbines tend to increase in size due to simultaneous effect of secondary flow and erosion in sediment affected hydropower plants. The pressure difference between the two sides of the guide vane induces leakage flow through the gap. This flow enters into the suction side with high acceleration, disturbing the primary flow and causing more erosion and losses in downstream turbine components. A cascade rig containing a single guide vane passage has been built to study the effect of the clearance gap using pressure sensors and PIV (Particle Image Velocimetry technique. This study focuses on developing a numerical model of the test rig, validating the results with experiments and investigating the behavior of leakage flow numerically. It was observed from both CFD and experiment that the leakage flow forms a passage vortex, which shifts away from the wall while travelling downstream. The streamlines contributing to the formation of this vortex have been discussed. Furthermore, the reference guide vane with symmetrical hydrofoil has been compared with four cambered profiles, in terms of the guide vane loading and the consequent effect on the leakage flow. A dimensionless term called Leakage Flow Factor (Lff has been introduced to compare the performances of hydrofoils. It is shown that the leakage flow and its effect on increasing losses and erosion can be minimized by changing the pressure distribution over the guide vane.

  2. Leakage-flow induced vibrations of a chimney structure suspended in a liquid flow

    International Nuclear Information System (INIS)

    Chung, H.

    1983-01-01

    This paper presents the results of flow-induced vibration tests conducted to assess the vibration characteristics of a chimney structure suspended in a liquid flow. The test article is a full-scale model of a flow chimney used in a nuclear reactor as a part of reactor upper internals. Tests were performed by simulating all pertinent prototype conditions achievable in a laboratory environment. The test results show that there exists a fluid-elastic instability of the chimney motion which has a distinct lock-in phenomenon with respect to the flow rate. This unstable vibration is associated with the leakage-flow-modulated excitation through the small clearances between the chimney and its supports

  3. Turbine Blade Tip-Gap Flow Physics and Control

    Science.gov (United States)

    Douville, Travis

    2005-11-01

    A linear cascade that is designed to simulate the flow around blades in the low-pressure turbine stage of turbo-jet engines is used to study the physics of the tip-gap flow and vortex. The cascade consists of three Pratt & Whitney ``PakB'' blades. The experiment investigated gap sizes of 0.5 to 5.0 percent of the blade axial chord, and Reynolds numbers from 100K to 500K that correspond to tip relative Mach numbers of 0.04 to 0.21. Static pressure ports at mid and tip spanwise locations recorded blade pressure distributions. Static end wall taps recorded pressures in the gap region. A five-hole Pitot probe that was traversed in the blade wakes was used to determine total pressure loss coefficients and local velocity vectors. Baseline measurements were analyzed across the range of Reynolds numbers and gap sizes to categorize their effects. These were then compared to flow changes produced by a passive flow control device placed at the end of a blade to locally reduce the gap height. Its effect on the tip-gap flow is presented.

  4. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Zoran [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Roessle, Martin; Schultheiss, Michael [University Medical Center Freiburg, Department of Gastroenterology, Freiburg (Germany); Euringer, Wulf; Langer, Mathias [University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Salem, Riad; Barker, Alex; Carr, James; Collins, Jeremy D. [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2015-09-15

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  5. An Experimental Investigation of the Flow Physics Associated With End Wall Losses and Large Rotor Tip Clearances as Found in the Rear Stages of a High Pressure Compressor

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2015-01-01

    The focus of this work was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearance heights were studied with nominal tip clearance heights of 1.5%, 3.0%, and 4.0% based on a constant annulus height. Overall compressor performance was investigated at four corrected speedlines (100%, 90%, 80%, and 68%) for each of the three tip clearance configurations using total pressure and total temperature rakes distributed throughout the compressor. The results have confirmed results from previous authors showing a decrease of total pressure rise, isentropic efficiency, and stall margin which is approximately linear with increasing tip clearance height. The stall inception mechanisms have also been evaluated at the same corrected speeds for each of the tip clearance configurations. Detailed flow field measurements have been collected at two loading conditions, nominal loading (NL) and high loading (HL), on the 100% corrected speedline for the smallest and largest tip clearance heights (1.5% and 4.0%). Steady detailed radial traverses of total pressure at the exit of each stator row have been supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data have helped to quantify the size of the leakage flow at the exit of each rotor. Thermal anemometry has also been implemented to evaluate the time-resolved three-dimensional components of velocity throughout the compressor and calculate blockage due to the rotor tip leakage flow throughout the compressor. These

  6. Algorithmic localisation of noise sources in the tip region of a low-speed axial flow fan

    Science.gov (United States)

    Tóth, Bence; Vad, János

    2017-04-01

    An objective and algorithmised methodology is proposed to analyse beamform data obtained for axial fans. Its application is demonstrated in a case study regarding the tip region of a low-speed cooling fan. First, beamforming is carried out in a co-rotating frame of reference. Then, a distribution of source strength is extracted along the circumference of the rotor at the blade tip radius in each analysed third-octave band. The circumferential distributions are expanded into Fourier series, which allows for filtering out the effects of perturbations, on the basis of an objective criterion. The remaining Fourier components are then considered as base sources to determine the blade-passage-periodic flow mechanisms responsible for the broadband noise. Based on their frequency and angular location, the base sources are grouped together. This is done using the fuzzy c-means clustering method to allow the overlap of the source mechanisms. The number of clusters is determined in a validity analysis. Finally, the obtained clusters are assigned to source mechanisms based on the literature. Thus, turbulent boundary layer - trailing edge interaction noise, tip leakage flow noise, and double leakage flow noise are identified.

  7. Attenuation of the tip vortex flow using a flexible thread

    Science.gov (United States)

    Lee, Seung-Jae; Shin, Jin-Woo; Arndt, Roger E. A.; Suh, Jung-Chun

    2018-01-01

    Tip vortex cavitation (TVC) is important in a number of practical engineering applications. The onset of TVC is a critical concern for navy surface ships and submarines that aim to increase their capability to evade detection. A flexible thread attachment at blade tips was recently suggested as a new method to delay the onset of TVC. Although the occurrence of TVC can be reduced using a flexible thread, no scientific investigation focusing on its mechanisms has been undertaken. Thus, herein, we experimentally investigated the use of the flexible thread to suppress TVC from an elliptical wing. These investigations were performed in a cavitation tunnel and involved an observation of TVC using high-speed cameras, motion tracking of the thread using image-processing techniques, and near-field flow measurements performed using stereoscopic particle image velocimetry. The experimental data suggested that the flexible thread affects the axial velocity field more than the circumferential velocity field around the TVC axis. Furthermore, we observed no clear dependence of the vortex core size, circulation, and flow unsteadiness on TVC suppression. However, the presence of the thread at the wing tip led to a notable reduction in the streamwise velocity field, thereby alleviating TVC.

  8. Assessment of leakage at the implant-abutment connection using a new gas flow method.

    Science.gov (United States)

    Fauroux, Marie-Alix; Levallois, Bernard; Yachouh, Jacques; Torres, Jacques-Henri

    2012-01-01

    The aim of this study was to evaluate, with a new gas flow technique, leakage at the implant/abutment junction in systems with four different connections. Five Branemark System, five One Morse, five Intra-lock System, and five Ankylos Plus implants and abutments were used. A hole was drilled in the apex of each implant to allow gas to flow through the connection from negative to atmospheric pressure. The gas flow was calculated (slope of pressure decrease, in hPa.s-1). Each connection was tested after both manual and key tightening. Statistical analysis was performed on a generalized linear model with repeated measurements. The significance level was set at α=.05. A global significant difference was observed between the various systems (P=.0001). After manual tightening, gas leakage was (Ln[hPa.s-1], means±standard deviations): One Morse: 0.20 (±1.70); Branemark System: -4.56 (±2.61); Intra-lock: -4.31 (±4.17); Ankylos Plus; -7.59 (±0.76). After key tightening, mean values were: One Morse: -2.51 (±2.72); Branemark System: -7.23 (±1.01); Intra-lock: -7.76 (±0.50); Ankylos Plus; -7.73 (±0.62). This study confirms that gas flow is an appropriate method to assess connection leakage. Ankylos Plus connection leakage was very low when the assembly was tightened manually. Among conical connection systems, low (Ankylos Plus) and high (One Morse) leakage was observed. This gas flow study suggests, therefore, that connection design is not the most important parameter for implant/abutment connection leakage.

  9. Simple methods for predicting gas leakage flows through cracks

    International Nuclear Information System (INIS)

    Ewing, D.J.F.

    1989-01-01

    This report presents closed-form approximate analytical formulae with which the flow rate out of a through-wall crack can be estimated. The crack is idealised as a rough, tapering, wedgeshaped channel and the fluid is idealised as an isothermal or polytropically-expanding perfect gas. In practice, uncertainties about the wall friction factor dominate over uncertainties caused by the fluid-dynamics simplifications. The formulae take account of crack taper and for outwardly-diverging cracks they predict flows within 12% of mathematically more accurate one-dimensional numerical models. Upper and lower estimates of wall friction are discussed. (author)

  10. A study on leakage-flow-induced vibrations: Pt. 1

    International Nuclear Information System (INIS)

    Inada, F.; Hayama, S.

    1990-01-01

    The viscous fluid-dynamic forces and the moments acting on the walls of a one-dimensional, narrow, tapered passage when one wall is vibrating in coupled translational and rotational modes are analyzed, and fluid-dynamic mass, damping and stiffness matrices are determined. By this means the mechanism of instability generated from the flow through a narrow passage is examined. In the case of a single-degree-of-freedom translational or rotational system, only diagonal components of the fluid-dynamic matrices are estimated, and it is found that both negative fluid-dynamic damping caused by the phase delay due to the fluid inertia and negative fluid-dynamic stiffness can occur. In the case of a single-degree-of-freedom translational system, if the passage is divergent, both negative fluid-dynamic damping and fluid-dynamic stiffness can occur. In the case of a single-degree-of-freedom rotational system, the area increment ratio of the passage, at which negative fluid-dynamic damping and fluid-dynamic stiffness can occur, changes remarkably with the location of the pivot. In the case of a two-degree-of-freedom translational and rotational system, it is difficult to conclude directly from the fluid-dynamic matrices whether the fluid-dynamic forces stabilize the system or not. (author)

  11. Change regularity of water quality parameters in leakage flow conditions and their relationship with iron release.

    Science.gov (United States)

    Liu, Jingqing; Shentu, Huabin; Chen, Huanyu; Ye, Ping; Xu, Bing; Zhang, Yifu; Bastani, Hamid; Peng, Hongxi; Chen, Lei; Zhang, Tuqiao

    2017-11-01

    The long-term stagnation in metal water supply pipes, usually caused by intermittent consumption patterns, will cause significant iron release and water quality deterioration, especially at the terminus of pipelines. Another common phenomenon at the terminus of pipelines is leakage, which is considered helpful by allowing seepage of low-quality drinking water resulting from long-term stagnation. In this study, the effect of laminar flow on alleviating water quality deterioration under different leakage conditions was investigated, and the potential thresholds of the flow rate, which can affect the iron release process, were discussed. Based on a galvanized pipe and ductile cast iron pipe pilot platform, which was established at the terminus of pipelines, this research was carried out by setting a series of leakage rate gradients to analyze the influence of different leakage flow rates on iron release, as well as the relationship with chemical and biological parameters. The results showed that the water quality parameters were obviously influenced by the change in flow velocity. Water quality was gradually improved with an increase in flow velocity, but its change regularity reflected a diversity under different flow rates (p iron release was remarkably correlated to the redox potential, dissolved oxygen, pH, iron-oxidized bacteria and sulfate-reducing bacteria. The cumulative total iron release (r = 0.587, p iron release rate (r = 0.71, p iron, the quantity and rate of total iron release remain relatively in an ideal and safe situation. Copyright © 2017. Published by Elsevier Ltd.

  12. Instantaneous and time-averaged flow fields of multiple vortices in the tip region of a ducted propulsor

    Energy Technology Data Exchange (ETDEWEB)

    Oweis, Ghanem F.; Ceccio, Steven L. [University of Michigan, Department of Mechanical Engineering, Ann Arbor, MI (United States)

    2005-05-01

    The instantaneous and time-averaged flow fields in the tip region of a ducted marine propulsor are examined. In this flow, a primary tip-leakage vortex interacts with a secondary, co-rotating trailing edge vortex and other co- and counter-rotating vorticity found in the blade wake. Planar particle imaging velocimetry (PIV) is used to examine the flow in a plane approximately perpendicular to the mean axis of the primary vortex. An identification procedure is used to characterize multiple regions of compact vorticity in the flow fields as series of Gaussian vortices. Significant differences are found between the vortex properties from the time-averaged flow fields and the average vortex properties identified in the instantaneous flow fields. Variability in the vortical flow field results from spatial wandering of the vortices, correlated fluctuations of the vortex strength and core size, and both correlated and uncorrelated fluctuations in the relative positions of the vortices. This variability leads to pseudo-turbulent velocity fluctuations. Corrections for some of this variability are performed on the instantaneous flow fields. The resulting processed flow fields reveal a significant increase in flow variability in a region relatively far downstream of the blade trailing edge, a phenomenon that is masked through the process of simple averaging. This increased flow variability is also accompanied by the inception of discrete vortex cavitation bubbles, which is an unexpected result, since the mean flow pressures in the region of inception are much higher than the vapor pressure of the liquid. This suggests that unresolved fine-scale vortex interactions and stretching may be occurring in the region of increased flow variability. (orig.)

  13. Instantaneous and time-averaged flow fields of multiple vortices in the tip region of a ducted propulsor

    Science.gov (United States)

    Oweis, Ghanem F.; Ceccio, Steven L.

    2005-05-01

    The instantaneous and time-averaged flow fields in the tip region of a ducted marine propulsor are examined. In this flow, a primary tip-leakage vortex interacts with a secondary, co-rotating trailing edge vortex and other co- and counter-rotating vorticity found in the blade wake. Planar particle imaging velocimetry (PIV) is used to examine the flow in a plane approximately perpendicular to the mean axis of the primary vortex. An identification procedure is used to characterize multiple regions of compact vorticity in the flow fields as series of Gaussian vortices. Significant differences are found between the vortex properties from the time-averaged flow fields and the average vortex properties identified in the instantaneous flow fields. Variability in the vortical flow field results from spatial wandering of the vortices, correlated fluctuations of the vortex strength and core size, and both correlated and uncorrelated fluctuations in the relative positions of the vortices. This variability leads to pseudo-turbulent velocity fluctuations. Corrections for some of this variability are performed on the instantaneous flow fields. The resulting processed flow fields reveal a significant increase in flow variability in a region relatively far downstream of the blade trailing edge, a phenomenon that is masked through the process of simple averaging. This increased flow variability is also accompanied by the inception of discrete vortex cavitation bubbles, which is an unexpected result, since the mean flow pressures in the region of inception are much higher than the vapor pressure of the liquid. This suggests that unresolved fine-scale vortex interactions and stretching may be occurring in the region of increased flow variability.

  14. CFD simulation of a screw compressor including leakage flows and rotor heating

    Science.gov (United States)

    Spille-Kohoff, Andreas, Dr.; Hesse, Jan; El Shorbagy, Ahmed

    2015-08-01

    Computational Fluid Dynamics (CFD) simulations have promising potential to become an important part in the development process of positive displacement (PD) machines. CFD delivers deep insights into the flow and thermodynamic behaviour of PD machines. However, the numerical simulation of such machines is more complex compared to dynamic pumps like turbines or fans. The fluid transport in size-changing chambers with very small clearances between the rotors, and between rotors and casing, demands complex meshes that change with each time step. Additionally, the losses due to leakage flows and the heat transfer to the rotors need high-quality meshes so that automatic remeshing is almost impossible. In this paper, setup steps and results for the simulation of a dry screw compressor are shown. The rotating parts are meshed with TwinMesh, a special hexahedral meshing program for gear pumps, gerotors, lobe pumps and screw compressors. In particular, these meshes include axial and radial clearances between housing and rotors, and beside the fluid volume the rotor solids are also meshed. The CFD simulation accounts for gas flow with compressibility and turbulence effects, heat transfer between gas and rotors, and leakage flows through the clearances. We show time- resolved results for torques, forces, interlobe pressure, mass flow, and heat flow between gas and rotors, as well as time- and space-resolved results for pressure, velocity, temperature etc. for different discharge ports and working points of the screw compressor. These results are also used as thermal loads for deformation simulations of the rotors.

  15. Numerical Investigation on the Effects of Self-Excited Tip Flow Unsteadiness and Blade Row Interactions on the Performance Predictions of Low Speed and Transonic Compressor Rotors

    Science.gov (United States)

    Lee, Daniel H.

    The impact blade row interactions can have on the performance of compressor rotors has been well documented. It is also well known that rotor tip clearance flows can have a large effect on compressor performance and stall margin and recent research has shown that tip leakage flows can exhibit self-excited unsteadiness at near stall conditions. However, the impact of tip leakage flow on the performance and operating range of a compressor rotor, relative to other important flow features such as upstream stator wakes or downstream potential effects, has not been explored. To this end, a numerical investigation has been conducted to determine the effects of self-excited tip flow unsteadiness, upstream stator wakes, and downstream blade row interactions on the performance prediction of low speed and transonic compressor rotors. Calculations included a single blade-row rotor configuration as well as two multi-blade row configurations: one where the rotor was modeled with an upstream stator and a second where the rotor was modeled with a downstream stator. Steady-state and time accurate calculations were performed using a RANS solver and the results were compared with detailed experimental data obtained in the GE Low Speed Research Compressor and the Notre Dame Transonic Rig at several operating conditions including near stall. Differences in the performance predictions between the three configurations were then used to determine the effect of the upstream stator wakes and the downstream blade row interactions. Results obtained show that for both the low speed and transonic research compressors used in this investigation time-accurate RANS analysis is necessary to accurately predict the stalling character of the rotor. Additionally, for the first time it is demonstrated that capturing the unsteady tip flow can have a larger impact on rotor performance predictions than adjacent blade row interactions.

  16. Rotating coherent flow structures as a source for narrowband tip clearance noise from axial fans

    Science.gov (United States)

    Zhu, Tao; Lallier-Daniels, Dominic; Sanjosé, Marlène; Moreau, Stéphane; Carolus, Thomas

    2018-03-01

    Noise from axial fans typically increases significantly as the tip clearance is increased. In addition to the broadband tip clearance noise at the design flow rate, narrowband humps also associated with the tip flow are observed in the far-field acoustic spectra at lower flow rate. In this study, both experimental and numerical methods are used to shed more light on the noise generation mechanism of this narrowband tip clearance noise and provide a unified description of this source. Unsteady aeroacoustic predictions with the Lattice-Boltzmann Method (LBM) are successfully compared with experiment. Such a validation allows using LBM data to conduct a detailed modal analysis of the pressure field for detecting rotating coherent flow structures which might be considered as noise sources. As previously found in ring fans the narrowband humps in the far-field noise spectra are found to be related to the tip clearance noise that is generated by an interaction of coherent flow structures present in the tip region with the leading edge of the impeller blades. The visualization of the coherent structures shows that they are indeed part of the unsteady tip clearance vortex structures. They are hidden in a complex, spatially and temporally inhomogeneous flow field, but can be recovered by means of appropriate filtering techniques. Their pressure trace corresponds to the so-called rotational instability identified in previous turbomachinery studies, which brings a unified picture of this tip-noise phenomenon for the first time.

  17. Oil flow in the oil well tube annulus of vertical bearing assemblies (leakage)

    International Nuclear Information System (INIS)

    Piao, Yinghu

    1997-01-01

    A numerical simulation and experimental flow visualization study was conducted to better understand oil well leakage, particularly in the annular clearance space surrounding the oil well tube. A test rig was developed to simulate the bearing's oil well tube annulus. A major feature of this rig was to allow visual access to the annular clearance space and to the region beneath the rotating runner where strong secondary flow effects are known to exist. The main method for tracing the secondary flow pathlines was a light sheet visualization technique using micro air bubbles as the tracer. The effect of runner speed on the pathlines was studied. The velocity of the oil flow was measured experimentally and the results were compared with numerical data. A numerical technique was developed to trace the micro air bubbles in the oil flow field using a three dimensional CFD code for laminar, axisymmetric flow with a free surface. The buoyancy effects of gravitational and centrifugal forces were considered when determining the pathline of air bubbles. Bubble size, oil viscosity and runner speed were some of the parameters that affect the path of the air bubbles

  18. Improved Efficiency of Small Core Turbines through Tip Leakage and Secondary Flow Mitigation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Aeronautics Research Mission Directorate has declared ultra-efficient commercial air vehicles a strategic area for development in the coming decade. With no...

  19. Tip-splitting instabilities in the channel Saffman-Taylor flow of constant viscosity elastic fluids

    International Nuclear Information System (INIS)

    Vlad, D. H.; Maher, J. V.

    2000-01-01

    Boger fluids are used to study viscous fingering growth in viscoelastic fluids in channel Hele-Shaw flow. We have found that the viscous finger growing in the Boger fluid is unstable to tip splitting at high velocities, in a regime where a Newtonian viscous finger is stable. No fracturelike instabilities were observed. We show that the viscoelastic normal stress differences arising in shear and extensional flow reach very high values at shear and extensional rates comparable to those achieved at the tip of the finger at the onset of tip splitting, and the fluid becomes highly anisotropic. The viscoelastic stress could affect the dynamics of the finger and induce the tip-splitting instability. (c) 2000 The American Physical Society

  20. Influence of artificial tip perturbation on asymmetric vortices flow over a chined fuselage

    Directory of Open Access Journals (Sweden)

    Shi Wei

    2015-08-01

    Full Text Available An experimental study was conducted with the aim of understanding behavior of asymmetric vortices flow over a chined fuselage. The tests were carried out in a wind tunnel at Reynolds number of 1.87 × 105 under the conditions of high angles of attack and zero angle of sideslip. The results show that leeward vortices flow becomes asymmetric vortices flow when angle of attack increases over 20°. The asymmetric vortices flow is asymmetry of two forebody vortices owing to the increase of angle of attack but not asymmetry of vortex breakdown which appears when angle of attack is above 35°. Asymmetric vortices flow is sensitive to tip perturbation and is non-deterministic due to randomly distributed natural minute geometrical irregularities on the nose tip within machining tolerance. Deterministic asymmetric vortices flow can be obtained by attaching artificial tip perturbation which can trigger asymmetric vortices flow and decide asymmetric vortices flow pattern. Triggered by artificial tip perturbation, the vortex on the same side with perturbation is in a higher position, and the other vortex on the opposite side is in a lower position. Vortex suction on the lower vortex side is larger, which corresponds to a side force pointing to the lower vortex side.

  1. Turbulent penetration in T-junction branch lines with leakage flow

    Energy Technology Data Exchange (ETDEWEB)

    Kickhofel, John, E-mail: kickhofel@lke.mavt.ethz.ch; Valori, Valentina, E-mail: v.valori@tudelft.nl; Prasser, H.-M., E-mail: prasser@lke.mavt.ethz.ch

    2014-09-15

    Highlights: • New T-junction facility designed for adiabatic high velocity ratio mixing studies. • Trends in scalar mixing RMS and average in branch line presented and discussed. • Turbulent penetration has unique power spectrum relevant to thermal fatigue. • Forced flow oscillations translate to peaks in power spectrum in branch line. - Abstract: While the study of T-junction mixing with branch velocity ratios of near 1, so called cross flow mixing, is well advanced, to the point of realistic reactor environment fluid–structure interaction experiments and CFD benchmarking, turbulent penetration studies remain an under-researched threat to primary circuit piping. A new facility has been constructed for the express purpose of studying turbulent penetration in branch lines of T-junctions in the context of the high cycle thermal fatigue problem in NPPs. Turbulent penetration, which may be the result of a leaking valve in a branch line or an unisolable branch with heat losses, induces a thermal cycling region which may result in high cycle fatigue damage and failures. Leakage flow experiments have been performed in a perpendicular T-junction in a horizontal orientation with 50 mm diameter main pipe and branch pipe at velocity ratios (main/branch) up to 400. Wire mesh sensors are used as a means of measuring the mixing scalar in adiabatic tests with deionized and tap water. The near-wall region of highest scalar fluctuations is seen to vary circumferentially and in depth in the branch a great deal depending on the velocity ratio. The power spectra of the mixing scalar in the region of turbulent penetration are found to be dominated by high amplitude fluctuations at low frequencies, of particular interest to thermal fatigue. Artificial velocity oscillations in the main pipe manifest in the mixing spectra in the branch line in the form of a peak, the magnitude of which grows with increasing local RMS.

  2. Compressible Turbulent Flow Numerical Simulations of Tip Vortex Cavitation

    NARCIS (Netherlands)

    Khatami, F.; van der Weide, Edwin Theodorus Antonius; Hoeijmakers, Hendrik Willem Marie

    2015-01-01

    For an elliptic Arndt’s hydrofoil numerical simulations of vortex cavitation are presented. An equilibrium cavitation model is employed. This single-fluid model assumes local thermodynamic and mechanical equilibrium in the mixture region of the flow, is employed. Furthermore, for characterizing the

  3. Tip studies using CFD and comparison with tip loss models

    DEFF Research Database (Denmark)

    Hansen, Martin Otto Laver; Johansen, J.

    2004-01-01

    The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD......The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD...

  4. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    Science.gov (United States)

    Sutanto, E.; Chandra, F.; Dinata, R.

    2017-05-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA.

  5. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    International Nuclear Information System (INIS)

    Sutanto, E; Chandra, F; Dinata, R

    2017-01-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA. (paper)

  6. Flow Cytometry of the Side Population: Tips & Tricks

    Directory of Open Access Journals (Sweden)

    Irene Sales-Pardo

    2006-01-01

    Full Text Available Background: The Side Population (SP has become an important hallmark for the definition of the stem cell compartment, especially in the detection of these cells and in their physical isolation by fluorescence-activated cell sorting (FACS. SP cells are CD34neg and were discovered using ultraviolet excitation based on the efflux of Hoechst 33342 (Ho342. Although the method works as originally described, we believe that this method is difficult for most investigators. First, because the ability to discriminate SP cells is based on the differential retention of Ho342 during a functional assay; second, because of the difficulties in setting the right experimental and acquisition conditions; and third, because the analysis of the acquired data requires an extensive expertise on flow cytometry to accurately detect the SP events. Methods: First of all and mainly for the SP application, the laser beam paths were exhaustively checked to ensure the lowest coefficients of variation. Blood suspensions were prepared by erythrocyte lysis with ammonium chloride and hematopoietic cells were labeled with Ho342. Results: The Ho342 concentration and the staining procedure are critical for the optimal resolution of the SP cells. Although UV laser alignment is very important to resolve the dim tail that outlines the SP, the problem with Ho342 excitation is not the Hoechst Blue emission, but rather the Hoechst Red's (because of the weak emission. Conclusions: Each laboratory must establish its own expected ranges based on its instrument and results may vary slightly due to instrument differences such as the narrowness of the band pass filters, laser power, laser emission wavelength, nozzle type, differential of pressure, light collection system (cuvette versus jet-in-air and beam shaping optics.

  7. Tracking Blade Tip Vortices for Numerical Flow Simulations of Hovering Rotorcraft

    Science.gov (United States)

    Kao, David L.

    2016-01-01

    Blade tip vortices generated by a helicopter rotor blade are a major source of rotor noise and airframe vibration. This occurs when a vortex passes closely by, and interacts with, a rotor blade. The accurate prediction of Blade Vortex Interaction (BVI) continues to be a challenge for Computational Fluid Dynamics (CFD). Though considerable research has been devoted to BVI noise reduction and experimental techniques for measuring the blade tip vortices in a wind tunnel, there are only a handful of post-processing tools available for extracting vortex core lines from CFD simulation data. In order to calculate the vortex core radius, most of these tools require the user to manually select a vortex core to perform the calculation. Furthermore, none of them provide the capability to track the growth of a vortex core, which is a measure of how quickly the vortex diffuses over time. This paper introduces an automated approach for tracking the core growth of a blade tip vortex from CFD simulations of rotorcraft in hover. The proposed approach offers an effective method for the quantification and visualization of blade tip vortices in helicopter rotor wakes. Keywords: vortex core, feature extraction, CFD, numerical flow visualization

  8. Automatic Tip Vortex Core Profiling for Numerical Flow Simulations of Rotorcraft in Hover

    Science.gov (United States)

    Kao, David L.; Chaderjian, Neal M.

    2010-01-01

    An automated approach is presented that extracts visual and quantitative data from vortex cores produced by Navier-Stokes simulations of rotorcraft in hover mode. This approach extracts contiguous rotor tip vortex-core trajectories, cross-flow velocity profiles, and vortex-core diameter variation with wake age (azimuth angle). This automated approach is faster and more accurate than a conventional manual approach. Moreover, this new approach allows for an efficient way to quantitatively compare vortex-core profiles from different flow simulations, e.g., grid resolution studies, and validate computed results with experimental data

  9. Experimental Study of Tip Vortex Flow from a Periodically Pitched Airfoil Section

    Science.gov (United States)

    Zaman, Khairul; Fagan, Amy; Mankbadi, Mina

    2016-01-01

    An experimental investigation of tip vortex flow from a NACA0012 airfoil, pitched periodically at various frequencies, is conducted in a low-speed wind tunnel. Initially, data for stationary airfoil held fixed at various angles-of-attack are gathered. Flow visualization pictures as well as detailed cross-sectional properties areobtained at various streamwise locations using hot-wire anemometry. Data include mean velocity, streamwise vorticity as well as various turbulent stresses. Preliminary data are also acquired for periodically pitched airfoil. These results are briefly presented in this extended abstract.

  10. Coupling of Multiphase Flow and Geomechanics in Fractured Porous Media: Application to CO2 Leakages from Natural and Stimulated Fractures

    Science.gov (United States)

    Ezzedine, S. M.

    2015-12-01

    Leakage to the atmosphere of a significant fraction of injected CO2 would constitute a failure of a geological CO2 storage project from a greenhouse gas mitigation perspective. We present a numerical model that simulates flow and transport of CO2 into heterogeneous subsurface systems. The model, StoTran, is a flexible numerical environment that uses state-of-the-art finite element and finite volume methods and unstructured adaptive mesh refinement scheme implemented using MPI and OpenMP protocols. Multiphase flow equations and the geomechanical equations are implicitly solved and either fully or sequentially coupled. StoTran can address inverse and forward problems under deterministic or stochastic conditions. For the current study, StoTran has been used to simulate several scenarios spanning from a homogeneous single layered reservoir to heterogeneous multi-layered systems, which including cap-rock with embedded fractures, have been simulated under different operations of CO2 injection and CO2 leakages conditions. Results show the impact of the injection and leakage rates on the time evolution of the spread of the CO2 plume, its interception of the fractured cap-rock and the risk associated with the contamination of the overlaying aquifer. Spatial and temporal moments have been calculated for different, deterministic of stochastic, subsurface physical and chemical properties. Spatial moments enable assessing the extent of the region of investigation under conditions of uncertainty. Furthermore, several leakage scenarios show the intermittence behavior and development of the CO2 plume in the subsurface; its first interception with the fractures located further far from the injection well then, at a second stage, its interception with the fracture within the immediate vicinity of the injection well. We will present a remedy to CO2 leakages from the reservoir in order to enhance a long term containment of the injected CO2. This work performed under the auspices of

  11. Numerical Modeling of CO2 and Brine Leakage through Open Fracture in a Fault Zone: Open Channel Flow or Darcy Flow

    Directory of Open Access Journals (Sweden)

    Ning Liu

    2017-01-01

    Full Text Available Understanding fluids migration and leakage risk along the fault zone is necessary to guarantee the safety of CO2 geological storage. The validity of Darcy’s law gets challenged in dealing with the flow in open fractures since the occurring of turbulence flow. In this study, we develop a 2D model with usage of T2Well, an integrated wellbore-reservoir simulator, to investigate the leakage problem along open fractures which are embedded in a fault zone from the deep injection reservoir to shallow aquifers. The results record a positive feedback of gas expansion and pressure response in fracture, which causes a quick downward propagation of highly gas saturated zone from the top of fracture and an easy gas breakthrough in the shallower aquifers. The decreasing of aperture size of fracture significantly enhances the leakage rates in fracture, but with less influences as aperture increases. In comparison, the Equivalent Porous Media models show a good approximation with the momentum model of large apertures but poor for the small one. Nevertheless, the differences are small in terms of final CO2 distribution among various aquifers, suggesting that Darcy’s law may be still “effective” in solving flow problem along fractures in a constant injection system at a large time scale.

  12. Computational fluid dynamics evaluation of flow reversal treatment of giant basilar tip aneurysm.

    Science.gov (United States)

    Alnæs, Martin Sandve; Mardal, Kent-Andre; Bakke, Søren; Sorteberg, Angelika

    2015-10-01

    Therapeutic parent artery flow reversal is a treatment option for giant, partially thrombosed basilar tip aneurysms. The effectiveness of this treatment has been variable and not yet studied by applying computational fluid dynamics. Computed tomography images and blood flow velocities acquired with transcranial Doppler ultrasonography were obtained prior to and after bilateral endovascular vertebral artery occlusion for a giant basilar tip aneurysm. Patient-specific geometries and velocity waveforms were used in computational fluid dynamics simulations in order to determine the velocity and wall shear stress changes induced by treatment. Therapeutic parent artery flow reversal lead to a dramatic increase in aneurysm inflow and wall shear stress (30 to 170 Pa) resulting in an increase in intra-aneurysmal circulation. The enlargement of the circulated area within the aneurysm led to a re-normalization of the wall shear stress and the aneurysm remained stable for more than 8 years thereafter. Therapeutic parent artery flow reversal can lead to unintended, potentially harmful changes in aneurysm inflow which can be quantified and possibly predicted by applying computational fluid dynamics. © The Author(s) 2015.

  13. The influence of tip clearance on performance and internal flow condition of fluid food pump using low viscous fluid

    International Nuclear Information System (INIS)

    Kubo, S; Ishioka, T; Fukutomi, J; Shigemitsu, T

    2012-01-01

    Fluid machines for fluid food have been used in wide variety of fields i.e. transportation, the filling, and for the improvement of quality of fluid foods. However, flow conditions of it are quite complicated because fluid foods are different from water. Therefore, design methods based on internal flow conditions have not been conducted. In this research, turbo-pumps having a small number of blades were used to decrease shear loss and keep wide flow passage. The influence of the tip clearance was investigated by the numerical analysis using the model with and without the tip clearance. In this paper, the influence of tip clearance on performances and internal flow conditions of turbo-pump using low viscous fluid were clarified by experimental and numerical analysis results. In addition, design methods based on the internal flow were considered. Further, the influences of viscosity on the performance characteristic and internal flow were investigated.

  14. Investigation of Unsteady Tip Clearance Flow in a Low-Speed One and Half Stage Axial Compressor with LES And PIV

    Science.gov (United States)

    Hah, Chunill; Hathaway, Michael; Katz, Joseph; Tan, David

    2015-01-01

    The primary focus of this paper is to investigate how a rotor's unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor when the rotor tip gap size is increased from 0.5 mm (0.49% of rotor tip blade chord, 2% of blade span) to 2.4 mm (2.34% chord, 4% span) at the design condition are investigated. The changes in unsteady tip clearance flow with the 0.62 % tip gap as the flow rate is reduced to near stall condition are also investigated. A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at these three flow conditions. Detailed Stereoscopic PIV (SPIV) measurements of the current flow fields were also performed at the Johns Hopkins University in a refractive index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. Unsteady tip clearance flow fields from LES are compared with the PIV measurements and both LES and PIV results are used to study changes in tip clearance flow structures. The current study shows that the tip clearance vortex is not a single structure as traditionally perceived. The tip clearance vortex is formed by multiple interlaced vorticities. Therefore, the tip clearance vortex is inherently unsteady. The multiple interlaced vortices never roll up to form a single structure. When phased-averaged, the tip clearance vortex appears as a single structure. When flow rate is reduced with the same tip gap, the tip clearance vortex rolls further upstream and the tip clearance vortex moves further radially inward and away from the suction side of the blade. When the tip gap size is increased at the design flow condition, the overall tip clearance vortex becomes stronger and it stays closer to the blade suction side and the vortex core extends all the way to the exit of the blade passage. Measured and calculated unsteady flow

  15. Computational modelling of flow and tip variations of aortic cannulae in cardiopulmonary bypass procedure

    Science.gov (United States)

    Thomas, Siti A.; Empaling, Shirly; Darlis, Nofrizalidris; Osman, Kahar; Dillon, Jeswant; Taib, Ishkrizat; Khudzari, Ahmad Zahran Md

    2017-09-01

    Aortic cannulation has been the gold standard for maintaining cardiovascular function during open heart surgery while being connected onto the heart lung machine. These cannulation produces high velocity outflow which may lead to adverse effect on patient condition, especially sandblasting effect on aorta wall and blood cells damage. This paper reports a novel design that was able to decrease high velocity outflow. There were three design factors of that was investigated. The design factors consist of the cannula type, the flow rate, and the cannula tip design which result in 12 variations. The cannulae type used were the spiral flow inducing cannula and the standard cannula. The flow rates are varied from three to five litres per minute (lpm). Parameters for each cannula variation included maximum velocity within the aorta, pressure drop, wall shear stress (WSS) area exceeding 15 Pa, and impinging velocity on the aorta wall were evaluated. Based on the result, spiral flow inducing cannulae is proposed as a better alternatives due to its ability to reduce outflow velocity. Meanwhile, the pressure drop of all variations are less than the limit of 100 mmHg, although standard cannulae yielded better result. All cannulae show low reading of wall shear stress which decrease the possibilities for atherogenesis formation. In conclusion, as far as velocity is concerned, spiral flow is better compared to standard flow across all cannulae variations.

  16. Experimental study on rotating instability mode characteristics of axial compressor tip flow

    Science.gov (United States)

    Tian, Jie; Yao, Dan; Wu, Yadong; Ouyang, Hua

    2018-04-01

    This paper investigates the rotating instabilities that occurred on the single-stage axial compressor designed for aerodynamic performance validation, which was tested with two sets of circumferential measuring points in combination. Circumferential mode characteristics of compressors are usually too high to be captured experimentally, and aliasing of the circumferential mode order occurs when not enough sensors are used. A calibration and prediction method to capture the higher circumferential mode of unsteady flow in a compressor was proposed. Unsteady pressure fluctuations near the tip region in an axial compressor were studied, and high circumferential mode characteristics were captured on both the blade passing frequency (BPF) and the rotational instability frequency (RIF) under different flow rate conditions based on this novel method. The characteristic RI spectrum with a broadband hump was present in a large range of flow conditions. Both the frequency range and the dominant circumferential mode order decreased as the flow rate decreased. Based on the calibrated mode characteristics, a rotating aerodynamic source model is used to explain the side-by-side peak of RIF spectrum and rotating characteristics of RI. The calibration and prediction method of the high circumferential mode is beneficial for the research of unsteady flow in an axial compressor.

  17. 3D pressure imaging of an aircraft propeller blade-tip flow by phase-locked stereoscopic PIV

    NARCIS (Netherlands)

    Ragni, D.; Van Oudheusden, B.W.; Scarano, F.

    2011-01-01

    The flow field at the tip region of a scaled DHC Beaver aircraft propeller, running at transonic speed, has been investigated by means of a multi-plane stereoscopic particle image velocimetry setup. Velocity fields, phase-locked with the blade rotational motion, are acquired across several planes

  18. A l2-month longitudinal in vitro leakage study on a new silicon-based root canal filling material (Gutta-Flow).

    Science.gov (United States)

    Kontakiotis, Evangelos G; Tzanetakis, Giorgos N; Loizides, Alexios L

    2007-06-01

    This study was performed to determine in vitro the short- and long-term sealing ability of a recently developed silicon-based root canal filling material (Gutta-Flow). Sixty human upper central incisors were divided into 3 groups (n = 20). The root canals were instrumented and obturated with laterally compacted gutta-percha and AH26 sealer (group 1), continuous-wave thermal compaction (System B technique) and AH26 sealer (group 2), and Gutta-Flow technique (group 3). Leakage along entire root canal fillings was measured by the movement of an air bubble in a micropipette connected to the experimental root using a fluid-transport model. Short-term leakage measurements were carried out for 3 hours after 24 hours of equilibrium establishment. Leakage was measured again and at 3, 6, and 12 months after the initial measurement. At the 3-hour measurement, no significant differences were found among the 3 experimental groups. Long-term leakage measurements showed that at 3 and 6 months no significant differences were existed between Gutta-Flow and the other 2 techniques. However, at 12 months, root canal fillings with Gutta-Flow leaked significantly less than fillings of lateral compaction and System B technique. Gutta-Flow technique showed a similar sealing ability to either lateral compaction or System B technique. This comparison improved significantly over time. These findings may be related to the possible expanding capacity of the material and the partial dissolution of the sealer over time in the other 2 groups.

  19. Numerical investigation of tip clearance effects on the performance of ducted propeller

    Directory of Open Access Journals (Sweden)

    Ding Yongle

    2015-09-01

    Full Text Available Tip clearance loss is a limitation of the improvement of turbomachine performance. Previous studies show the Tip clearance loss is generated by the leakage flow through the tip clearance, and is roughly linearly proportional to the gap size. This study investigates the tip clearance effects on the performance of ducted propeller. The investigation was carried out by solving the Navier-Stokes equations with the commercial Computational Fluid Dynamic (CFD code CFX14.5. These simulations were carried out to determine the underlying mechanisms of the tip clearance effects. The calculations were performed at three different chosen advance ratios. Simulation results showed that the tip loss slope was not linearly at high advance due to the reversed pressure at the leading edge. Three type of vortical structures were observed in the tip clearance at different clearance size.

  20. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  1. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    Science.gov (United States)

    Erler, Engin

    region, this approach would entail a nominal performance penalty. Therefore, the chosen rotor design philosophy aims to keep the spanwise loading constant to avoid trading performance for desensitization. The rotor designs that resulted from this exercise are simulated in ANSYS CFX at different tip clearance sizes. The change in their performance with respect to tip clearance size (sensitivity) is compared both on an integral level in terms of pressure ratio and adiabatic efficiency, as well as on a detailed level in terms of aerodynamic losses and blockage associated with tip clearance flow. The sensitivity of aerodynamic stability is evaluated either directly through the simulations of the rotor characteristics up to the stall point (expensive in time and resources) for a few designs or indirectly through the position of the interface between the incoming and tip clearance flow with respect to the rotor leading edge plane. The latter approach is based on a generally observed stall criteria in modern axial compressors. The rotor designs are then assessed according to their sensitivity in comparison to that of the reference rotor design to detect features that can explain the trend in sensitivity to tip clearance size. These features can then be validated and the associated flow mechanisms explained through numerical simulations and modelling. Analysis of the database from the rotor parametric study shows that the observed trend in sensitivity cannot be explained by the shifting of the aerodynamic loading along the blade chord, as initially hypothesized based on the literature review. Instead, two flow features are found to reduce sensitivity of performance and stability to tip clearance, namely an increase in incoming meridional momentum in the tip region and a reduction/elimination of double leakage flow. Double leakage flow is the flow that exits the tip clearance of one blade and proceeds into the clearance of the adjacent blade rather than convecting downstream out

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... TIPS is a minimally invasive procedure that typically has a shorter recovery time than surgery. Your TIPS ...

  3. Leakage detection algorithm integrating water distribution networks hydraulic model

    CSIR Research Space (South Africa)

    Adedeji, K

    2017-06-01

    Full Text Available and estimation is vital for effective water service. For effective detection of background leakages, a hydraulic analysis of flow characteristics in water piping networks is indispensable for appraising such type of leakage. A leakage detection algorithm...

  4. TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps

    International Nuclear Information System (INIS)

    Mendrik, Adrienne M; Van Ginneken, Bram; Viergever, Max A; Vonken, Evert-jan; De Jong, Hugo W; Riordan, Alan; Van Seeters, Tom; Smit, Ewoud J; Prokop, Mathias

    2011-01-01

    Cerebral computed tomography perfusion (CTP) scans are acquired to detect areas of abnormal perfusion in patients with cerebrovascular diseases. These 4D CTP scans consist of multiple sequential 3D CT scans over time. Therefore, to reduce radiation exposure to the patient, the amount of x-ray radiation that can be used per sequential scan is limited, which results in a high level of noise. To detect areas of abnormal perfusion, perfusion parameters are derived from the CTP data, such as the cerebral blood flow (CBF). Algorithms to determine perfusion parameters, especially singular value decomposition, are very sensitive to noise. Therefore, noise reduction is an important preprocessing step for CTP analysis. In this paper, we propose a time-intensity profile similarity (TIPS) bilateral filter to reduce noise in 4D CTP scans, while preserving the time-intensity profiles (fourth dimension) that are essential for determining the perfusion parameters. The proposed TIPS bilateral filter is compared to standard Gaussian filtering, and 4D and 3D (applied separately to each sequential scan) bilateral filtering on both phantom and patient data. Results on the phantom data show that the TIPS bilateral filter is best able to approach the ground truth (noise-free phantom), compared to the other filtering methods (lowest root mean square error). An observer study is performed using CBF maps derived from fifteen CTP scans of acute stroke patients filtered with standard Gaussian, 3D, 4D and TIPS bilateral filtering. These CBF maps were blindly presented to two observers that indicated which map they preferred for (1) gray/white matter differentiation, (2) detectability of infarcted area and (3) overall image quality. Based on these results, the TIPS bilateral filter ranked best and its CBF maps were scored to have the best overall image quality in 100% of the cases by both observers. Furthermore, quantitative CBF and cerebral blood volume values in both the phantom and the

  5. TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps

    Energy Technology Data Exchange (ETDEWEB)

    Mendrik, Adrienne M; Van Ginneken, Bram; Viergever, Max A [Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Vonken, Evert-jan; De Jong, Hugo W; Riordan, Alan; Van Seeters, Tom; Smit, Ewoud J; Prokop, Mathias, E-mail: a.m.mendrik@gmail.com [Radiology Department, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2011-07-07

    Cerebral computed tomography perfusion (CTP) scans are acquired to detect areas of abnormal perfusion in patients with cerebrovascular diseases. These 4D CTP scans consist of multiple sequential 3D CT scans over time. Therefore, to reduce radiation exposure to the patient, the amount of x-ray radiation that can be used per sequential scan is limited, which results in a high level of noise. To detect areas of abnormal perfusion, perfusion parameters are derived from the CTP data, such as the cerebral blood flow (CBF). Algorithms to determine perfusion parameters, especially singular value decomposition, are very sensitive to noise. Therefore, noise reduction is an important preprocessing step for CTP analysis. In this paper, we propose a time-intensity profile similarity (TIPS) bilateral filter to reduce noise in 4D CTP scans, while preserving the time-intensity profiles (fourth dimension) that are essential for determining the perfusion parameters. The proposed TIPS bilateral filter is compared to standard Gaussian filtering, and 4D and 3D (applied separately to each sequential scan) bilateral filtering on both phantom and patient data. Results on the phantom data show that the TIPS bilateral filter is best able to approach the ground truth (noise-free phantom), compared to the other filtering methods (lowest root mean square error). An observer study is performed using CBF maps derived from fifteen CTP scans of acute stroke patients filtered with standard Gaussian, 3D, 4D and TIPS bilateral filtering. These CBF maps were blindly presented to two observers that indicated which map they preferred for (1) gray/white matter differentiation, (2) detectability of infarcted area and (3) overall image quality. Based on these results, the TIPS bilateral filter ranked best and its CBF maps were scored to have the best overall image quality in 100% of the cases by both observers. Furthermore, quantitative CBF and cerebral blood volume values in both the phantom and the

  6. 3D pressure imaging of an aircraft propeller blade-tip flow by phase-locked stereoscopic PIV

    Energy Technology Data Exchange (ETDEWEB)

    Ragni, D.; Oudheusden, B.W. van; Scarano, F. [Delft University of Technology, Faculty of Aerospace Engineering, Delft (Netherlands)

    2012-02-15

    The flow field at the tip region of a scaled DHC Beaver aircraft propeller, running at transonic speed, has been investigated by means of a multi-plane stereoscopic particle image velocimetry setup. Velocity fields, phase-locked with the blade rotational motion, are acquired across several planes perpendicular to the blade axis and merged to form a 3D measurement volume. Transonic conditions have been reached at the tip region, with a revolution frequency of 19,800 rpm and a relative free-stream Mach number of 0.73 at the tip. The pressure field and the surface pressure distribution are inferred from the 3D velocity data through integration of the momentum Navier-Stokes equation in differential form, allowing for the simultaneous flow visualization and the aerodynamic loads computation, with respect to a reference frame moving with the blade. The momentum and pressure data are further integrated by means of a contour-approach to yield the aerodynamic sectional force components as well as the blade torsional moment. A steady Reynolds averaged Navier-Stokes numerical simulation of the entire propeller model has been used for comparison to the measurement data. (orig.)

  7. 3D pressure imaging of an aircraft propeller blade-tip flow by phase-locked stereoscopic PIV

    Science.gov (United States)

    Ragni, D.; van Oudheusden, B. W.; Scarano, F.

    2012-02-01

    The flow field at the tip region of a scaled DHC Beaver aircraft propeller, running at transonic speed, has been investigated by means of a multi-plane stereoscopic particle image velocimetry setup. Velocity fields, phase-locked with the blade rotational motion, are acquired across several planes perpendicular to the blade axis and merged to form a 3D measurement volume. Transonic conditions have been reached at the tip region, with a revolution frequency of 19,800 rpm and a relative free-stream Mach number of 0.73 at the tip. The pressure field and the surface pressure distribution are inferred from the 3D velocity data through integration of the momentum Navier-Stokes equation in differential form, allowing for the simultaneous flow visualization and the aerodynamic loads computation, with respect to a reference frame moving with the blade. The momentum and pressure data are further integrated by means of a contour-approach to yield the aerodynamic sectional force components as well as the blade torsional moment. A steady Reynolds averaged Navier-Stokes numerical simulation of the entire propeller model has been used for comparison to the measurement data.

  8. Impact of irrigation flow rate and intrapericardial fluid on cooled-tip epicardial radiofrequency ablation.

    Science.gov (United States)

    Aryana, Arash; O'Neill, Padraig Gearoid; Pujara, Deep K; Singh, Steve K; Bowers, Mark R; Allen, Shelley L; d'Avila, André

    2016-08-01

    The optimal irrigation flow rate (IFR) during epicardial radiofrequency (RF) ablation has not been established. This study specifically examined the impact of IFR and intrapericardial fluid (IPF) accumulation during epicardial RF ablation. Altogether, 452 ex vivo RF applications (10 g for 60 seconds) delivered to the epicardial surface of bovine myocardium using 3 open-irrigated ablation catheters (ThermoCool SmartTouch, ThermoCool SmartTouch-SF, and FlexAbility) and 50 in vivo RF applications delivered (ThermoCool SmartTouch-SF) in 4 healthy adult swine in the presence or absence of IPF were examined. Ex vivo, RF was delivered at low (≤3 mL/min), reduced (5-7 mL/min), and high (≥10 mL/min) IFRs using intermediate (25-35 W) and high (35-45 W) power. In vivo, applications were delivered (at 9.3 ± 2.2 g for 60 seconds at 39 W) using reduced (5 mL/min) and high (15 mL/min) IFRs. Ex vivo, surface lesion diameter inversely correlated with IFR, whereas maximum lesion diameter and depth did not differ. While steam pops occurred more frequently at low IFR using high power (ThermoCool SmartTouch and ThermoCool SmartTouch-SF), tissue disruption was rare and did not vary with IFR. In vivo, charring/steam pop was not detected. Although there were no discernible differences in lesion size with IFR, surface lesion diameter, maximum diameter, depth, and volume were all smaller in the presence of IPF at both IFRs. Cooled-tip epicardial RF ablation created using reduced IFRs (5-7 mL/min) yields lesion sizes similar to those created using high IFRs (≥10 mL/min) without an increase in steam pop/tissue disruption, whereas the presence of IPF significantly reduces the lesion size. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  9. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  10. Fast and Near-Optimal Timing-Driven Cell Sizing under Cell Area and Leakage Power Constraints Using a Simplified Discrete Network Flow Algorithm

    Directory of Open Access Journals (Sweden)

    Huan Ren

    2013-01-01

    Full Text Available We propose a timing-driven discrete cell-sizing algorithm that can address total cell size and/or leakage power constraints. We model cell sizing as a “discretized” mincost network flow problem, wherein available sizes of each cell are modeled as nodes. Flow passing through a node indicates the choice of the corresponding cell size, and the total flow cost reflects the timing objective function value corresponding to these choices. Compared to other discrete optimization methods for cell sizing, our method can obtain near-optimal solutions in a time-efficient manner. We tested our algorithm on ISCAS’85 benchmarks, and compared our results to those produced by an optimal dynamic programming- (DP- based method. The results show that compared to the optimal method, the improvements to an initial sizing solution obtained by our method is only 1% (3% worse when using a 180 nm (90 nm library, while being 40–60 times faster. We also obtained results for ISPD’12 cell-sizing benchmarks, under leakage power constraint, and compared them to those of a state-of-the-art approximate DP method (optimal DP runs out of memory for the smallest of these circuits. Our results show that we are only 0.9% worse than the approximate DP method, while being more than twice as fast.

  11. Investigation of the Compressible Flow through the Tip-Section Turbine Blade Cascade with Supersonic Inlet

    Czech Academy of Sciences Publication Activity Database

    Luxa, Martin; Příhoda, Jaromír; Šimurda, David; Straka, P.; Synáč, J.

    2016-01-01

    Roč. 25, č. 2 (2016), s. 138-144 ISSN 1003-2169 R&D Projects: GA TA ČR(CZ) TA03020277; GA ČR GAP101/12/1271 Institutional support: RVO:61388998 Keywords : long turbine rotor blade * supersonic tip section * optical methods * transition modelling * CFD Subject RIV: BK - Fluid Dynamics Impact factor: 0.678, year: 2016

  12. Numerical simulation of tip clearance impact on a pumpjet propulsor

    Directory of Open Access Journals (Sweden)

    Lin Lu

    2016-05-01

    Full Text Available Numerical simulation based on the Reynolds Averaged Navier–Stokes (RANS Computational Fluid Dynamics (CFD method had been carried out with the commercial code ANSYS CFX. The structured grid and SST k–ω turbulence model had been adopted. The impact of non-condensable gas (NCG on cavitation performance had been introduced into the Schnerr and Sauer cavitation model. The numerical investigation of cavitating flow of marine propeller E779A was carried out with different advance ratios and cavitation numbers to verify the numerical simulation method. Tip clearance effects on the performance of pumpjet propulsor had been investigated. Results showed that the structure and characteristics of the tip leakage vortex and the efficiency of the propulsor dropped more sharply with the increase of the tip clearance size. Furthermore, the numerical simulation of tip clearance cavitation of pumpjet propulsor had been presented with different rotational speed and tip clearance size. The mechanism of tip clearance cavitation causing a further loss of the efficiency had been studied. The influence of rotational speed and tip clearance size on tip clearance cavitation had been investigated.

  13. Hydrologic conditions in urban Miami-Dade County, Florida, and the effect of groundwater pumpage and increased sea level on canal leakage and regional groundwater flow

    Science.gov (United States)

    Hughes, Joseph D.; White, Jeremy T.

    2014-01-01

    The extensive and highly managed surface-water system in southeastern Florida constructed during the 20th Century has allowed for the westward expansion of urban and agricultural activities in Miami-Dade County. In urban areas of the county, the surface-water system is used to (1) control urban flooding, (2) supply recharge to production well fields, and (3) control seawater intrusion. Previous studies in Miami-Dade County have determined that on a local scale, leakage from canals adjacent to well fields can supply a large percentage (46 to 78 percent) of the total groundwater pumpage from production well fields. Canals in the urban areas also receive seepage from the Biscayne aquifer that is derived from a combination of local rainfall and groundwater flow from Water Conservation Area 3 and Everglades National Park, which are west of urban areas of Miami-Dade County.

  14. Remembering tips

    Science.gov (United States)

    Memory aids; Alzheimer disease - remembering tips; Early memory loss - remembering tips; Dementia - remembering tips ... active: Read a lot if you have trouble remembering words. Keep a dictionary close by. Take part ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in ... TIPS reroutes blood flow in the liver and reduces abnormally high blood pressure in the veins of ...

  16. Tips for TIPS

    NARCIS (Netherlands)

    Cuijpers, C.F.

    2015-01-01

    The transjugular intrahepatic portosystemic shunt (TIPS) procedure is one of the most technically challenging procedures in interventional radiology. During the procedure, interventional radiologists (IRs) insert very thin and long instruments through a little incision in the patient’s neck. They

  17. Analysis of Unsteady Tip and Endwall Heat Transfer in a Highly Loaded Transonic Turbine Stage

    Science.gov (United States)

    Shyam, Vikram; Ameri, Ali; Chen, Jen-Ping

    2010-01-01

    In a previous study, vane-rotor shock interactions and heat transfer on the rotor blade of a highly loaded transonic turbine stage were simulated. The geometry consists of a high pressure turbine vane and downstream rotor blade. This study focuses on the physics of flow and heat transfer in the rotor tip, casing and hub regions. The simulation was performed using the Unsteady Reynolds-Averaged Navier-Stokes (URANS) code MSU-TURBO. A low Reynolds number k-epsilon model was utilized to model turbulence. The rotor blade in question has a tip gap height of 2.1 percent of the blade height. The Reynolds number of the flow is approximately 3x10(exp 6) per meter. Unsteadiness was observed at the tip surface that results in intermittent "hot spots". It is demonstrated that unsteadiness in the tip gap is governed by inviscid effects due to high speed flow and is not strongly dependent on pressure ratio across the tip gap contrary to published observations that have primarily dealt with subsonic tip flows. The high relative Mach numbers in the tip gap lead to a choking of the leakage flow that translates to a relative attenuation of losses at higher loading. The efficacy of new tip geometry is discussed to minimize heat flux at the tip while maintaining choked conditions. In addition, an explanation is provided that shows the mechanism behind the rise in stagnation temperature on the casing to values above the absolute total temperature at the inlet. It is concluded that even in steady mode, work transfer to the near tip fluid occurs due to relative shearing by the casing. This is believed to be the first such explanation of the work transfer phenomenon in the open literature. The difference in pattern between steady and time-averaged heat flux at the hub is also explained.

  18. Apical pressure and extent of irrigant flow beyond the needle tip during positive-pressure irrigation in an in vitro root canal model.

    Science.gov (United States)

    Park, Ellen; Shen, Ya; Khakpour, Mehrzad; Haapasalo, Markus

    2013-04-01

    This study aimed to measure the pressure generated during positive-pressure irrigation at the periapex of an in vitro tooth model using a novel method of measurement, investigating the effect of flow rate and needle design. Apical pressure was correlated with the extent of dye clearance from the end of a needle tip in a plastic root canal model with similar dimensions. The mesiobuccal canal of a mandibular molar was instrumented to #35/06 and placed into a chamber coupled to a pressure transducer. Irrigation was performed using a digital peristaltic pump using flow rates from 1-15 mL/min with irrigation needles of different sizes and designs. A plastic root canal model instrumented to the same size filled with dye was used to measure the extent of dye clearance beyond the needle tip using the same irrigation conditions. Positive-pressure irrigation revealed a flow rate-dependent increase in apical pressure (P irrigation flow rates was several times higher than at low flow rates. Needle designs with safety features yielded statistically significant lower apical pressures than needles without safety features (P model at flow rates higher than 4 mL/min. If apical clearance of dye beyond the needle tip is a measure of irrigation effectiveness, then maximum effectiveness with safe apical pressures can be gained at specific flow rates using specific needle tip designs. The use of an irrigation flow rate of 4 mL/min was able to achieve maximum effectiveness in this study. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Measurement and analysis of radiated sound from a low speed fan with a large tip gap.

    Science.gov (United States)

    Bilka, M J; Anthoine, J; Schram, C

    2014-05-01

    The wake flow field and radiated sound from a low speed axial fan is studied experimentally. The fan geometry uses controlled diffusion blades and is designed with a low aspect ratio (0.9). The fan is installed with a large tip gap, approximately 10% of the blade span. The radiated sound field is analyzed using a known trailing edge noise formulation. First, the model is compared to an experiment of a single airfoil in a wind tunnel to assess the predictive capabilities. Second, measurements of the fan are made at two different blade loading conditions. Hot wire measurements are made in the near wake of the fan to assess the extent of the tip leakage flow for each condition. The radiated sound fields are compared with the trailing edge noise theory. Use is made of the wake measurements as an input to a surface pressure model. When the fan is operated with the optimal blade loading, the influence of the tip leakage flow is found to be of secondary acoustic impact. When the fan is operated at a high loading condition for the blades, a more significant leakage flow develops and is found to be responsible for the dominant radiated sound.

  20. Study on the annular leakage-flow-induced vibrations. 1st Report. Stability for translational and rotational single-degree-of-freedom systems; Kanjo sukimaryu reiki shindo ni kansuru kenkyu. 1. Heishin oyobi kaiten 1 jiyudokei no anteise

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.W. [Hitachi, Ltd., Tokyo (Japan); Kaneko, S. [The University of Tokyo, Tokyo (Japan); Hayama, S. [Toyama Prefectural University, Toyama (Japan)

    1999-07-25

    This study reports the stability of annular leakage-flow-induced vibrations. The pressure distribution of fluid between a fixed outer cylinder and a vibrating inner cylinder was obtained in the case of a translationally and rotationally coupled motion of the inner cylinder. The unsteady fluid force acting on the inner cylinder in the case of translational and rotational single-degree-of-freedom vibrations was then expressed in terms proportional to the acceleration, velocity, and displacement. Then the critical flow rate (at which stability was lost) was determined for an annular leakage-flow-induced vibration. Finally, the stability was investigated theoretically. It is known that instability will occur in the case of a divergent passage, but the critical flow rate depends on the passage increment in a limited range: the eccentricity of the passage and the pressure loss factor at the inlet of the passage lower the stability. (author)

  1. Heat Transfer and Flow on the First Stage Blade Tip of a Power Generation Gas Turbine. Part 1; Experimental Results

    Science.gov (United States)

    Bunker, Ronald S.; Bailey, Jeremy C.; Ameri, Ali A.

    1999-01-01

    A combined computational and experimental study has been performed to investigate the detailed distribution of convective heat transfer coefficients on the first stage blade tip surface for a geometry typical of large power generation turbines(>100MW). This paper is concerned with the design and execution of the experimental portion of the study. A stationary blade cascade experiment has been run consisting of three airfoils, the center airfoil having a variable tip gap clearance. The airfoil models the aerodynamic tip section of a high pressure turbine blade with inlet Mach number of 0.30, exit Mach number of 0.75, pressure ratio of 1.45, exit Reynolds number based on axial chord of 2.57 x 10(exp 6), and total turning of about 110 degrees. A hue detection based liquid crystal method is used to obtain the detailed heat transfer coefficient distribution on the blade tip surface for flat, smooth tip surfaces with both sharp and rounded edges. The cascade inlet turbulence intensity level took on values of either 5% or 9%. The cascade also models the casing recess in the shroud surface ahead of the blade. Experimental results are shown for the pressure distribution measurements on the airfoil near the tip gap, on the blade tip surface, and on the opposite shroud surface. Tip surface heat transfer coefficient distributions are shown for sharp-edge and rounded-edge tip geometries at each of the inlet turbulence intensity levels.

  2. Convective Leakage Makes Heparin Locking of Central Venous Catheters Ineffective Within Seconds: Experimental Measurements in a Model Superior Vena Cava.

    Science.gov (United States)

    Barbour, Michael C; McGah, Patrick M; Ng, Chin H; Clark, Alicia M; Gow, Kenneth W; Aliseda, Alberto

    2015-01-01

    Central venous catheters (CVCs), placed in the superior vena cava (SVC) for hemodialysis or chemotherapy, are routinely filled while not in use with heparin, an anticoagulant, to maintain patency and prevent thrombus formation at the catheter tip. The heparin-locking procedure, however, places the patient at risk for systemic bleeding, as heparin is known to leak from the catheter into the blood stream. We provide evidence from detailed in vitro experiments that shows the driving mechanism behind heparin leakage to be convective-diffusive transport due to the pulsatile flow surrounding the catheter. This novel mechanism is supported by experimental planar laser-induced fluorescence (PLIF) and particle image velocimetry (PIV) measurements of flow velocity and heparin transport from a CVC placed inside a model SVC inside a pulsatile flow loop. The results predict an initial, fast (<10 s), convection-dominated phase that rapidly depletes the concentration of heparin in the near-tip region, the region of the catheter with side holes. This is followed by a slow, diffusion-limited phase inside the catheter lumen, where the concentration is still high, that is insufficient at replenishing the lost heparin concentration in the near-tip region. The results presented here, which are consistent with previous in vivo estimates of 24 hour leakage rates, predict that the concentration of heparin in the near-tip region is essentially zero for the majority of the interdialytic phase, rendering the heparin locking procedure ineffective.

  3. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    Monju is Japan's prototype fast breeder reactor: 280 MWe (714 MWt), fueled with mixed oxides of plutonium and uranium, cooled by liquid sodium. Construction was started in 1985 and initial criticality was attained in April 1994. On 8th December 1995, sodium leakage from a secondary circuit occurred in a piping room of the reactor auxiliary building. The secondary sodium leaked through a temperature sensor, due to the breakaway of the tip of the thermocouple well tube installed near the secondary circuit outlet of the intermediate heat exchanger (IHX). The reactor remained cooled and thus, from the viewpoint of radiological hazards, the safety of the reactor was secured. There was no release of radioactive material. There were no adverse effects for personnel and the surrounding environment. The thermocouple well tube failure resulted from high cycle fatigue due to flow induced vibration. It was found that this flow induced vibration was not caused by well-known Von Karman vortex shedding, but a symmetric vortex shedding. The design of the thermocouple well, which was subject to avoid this phenomenon, was reviewed. A new design guide against the flow-induced vibration was prepared by JNC (Japan Nuclear Cycle Development Institute). This is more comprehensive and definitive than the existing guide 'ASME N-1300' (Flow-induced vibration of tube and tube banks). New thermocouple well designs were proposed consistent with this design guide. To prevent a recurrence of the secondary sodium leakage incident, comprehensive design review activities were started for the purpose of checking the safety and reliability of the plant. As a result, several aspects to be improved were identified and improvements and countermeasures have been studied. The main improvements and countermeasures are as follows: To enable the operators to understand and react to incidents quickly, new sodium leakage detectors (TV monitors, smoke sensors) and a new surveillance system will be installed; To

  4. Tipping Point

    Medline Plus

    Full Text Available ... death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ... tv tip-overs. The force of a large television falling from tipping furniture can be staggering. A ...

  5. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  6. Experimental investigation of flow field in a laboratory-scale compressor

    Directory of Open Access Journals (Sweden)

    Hongwei Ma

    2017-02-01

    Full Text Available The inner flow environment of turbomachinery presents strong three-dimensional, rotational, and unsteady characteristics. Consequently, a deep understanding of these flow phenomena will be the prerequisite to establish a state-of-the-art design system of turbomachinery. Currently the development of more accurate turbulence models and CFD tools is in urgent need for a high-quality database for validation, especially the advanced CFD tools, such as large eddy simulation (LES. Under this circumstance, this paper presents a detailed experimental investigation on the 3D unsteady flow field inside a laboratory-scale isolated-rotor with multiple advanced measurement techniques, including traditional aerodynamic probes, hotwire probes, unsteady endwall static pressure measurement, and stereo particle image velocimetry (SPIV. The inlet boundary layer profile is measured with both hotwire probe and aerodynamic probe. The steady and unsteady flow fields at the outlet of the rotor are measured with a mini five-hole probe and a single-slanted hotwire probe. The instantaneous flow field in the rotor tip region inside the passage is captured with SPIV, and then a statistical analysis of the spatial distribution of the instantaneous tip leakage vortex/flow is performed to understand its dynamic characteristics. Besides these, the uncertainty analysis of each measurement technique is described. This database is quite sufficient to validate the advanced numerical simulation with LES. The identification process of the tip leakage vortex core in the instantaneous frames obtained from SPIV is performed deliberately. It is concluded that the ensemble-averaged flow field could not represent the tip leakage vortex strength and the trajectory trace. The development of the tip leakage vortex could be clearly cataloged into three phases according to their statistical spatial distribution. The streamwise velocity loss induced by the tip leakage flow increases until the

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... system. This pressure buildup can cause blood to flow backward from the liver into the veins of ... does the procedure work? A TIPS reroutes blood flow in the liver and reduces abnormally high blood ...

  8. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  9. CPAP Tips

    Medline Plus

    Full Text Available ... a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from the U.S. Food ... 395,755 views 9:28 3 Tips for Sleeping With a CPAP - Duration: 2:02. WebMD 66, ...

  10. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  11. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  12. Inward Leakage in Tight-Fitting PAPRs

    Directory of Open Access Journals (Sweden)

    Frank C. Koh

    2011-01-01

    Full Text Available A combination of local flow measurement techniques and fog flow visualization was used to determine the inward leakage for two tight-fitting powered air-purifying respirators (PAPRs, the 3M Breathe-Easy PAPR and the SE 400 breathing demand PAPR. The PAPRs were mounted on a breathing machine head form, and flows were measured from the blower and into the breathing machine. Both respirators leaked a little at the beginning of inhalation, probably through their exhalation valves. In both cases, the leakage was not enough for fog to appear at the mouth of the head form.

  13. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  14. Pressure Gauges Monitor Leakage Past Seals

    Science.gov (United States)

    Smith, Steven A.

    1990-01-01

    Method devised to measure leakage of gas past each of two sets of primary and secondary seals into common volume from which aggregate flow measured. Although method applicable only to specific combination of flow configuration and thermal conditions, it serves as example of more general approach involving use of statistical analysis to extract additional information from measurements.

  15. Valve packing leakage monitoring device

    International Nuclear Information System (INIS)

    Ezekoye, L.I.

    1985-01-01

    A device for monitoring leakage of fluid across a seal in a component connected to a pressurized fluid system including a housing having a chamber with an inlet for receiving fluid leaking across the seal and an outlet. A positioning means is connected to an orifice plug so as to move the plug for permitting the fluid to be discharged through the orifice at the same rate at which it enters the first chamber and means for detecting the movement of the plug is provided to produce and output signal corresponding to the distance moved by the plug and thereby indicate flow rate. The positioning means compromise a piston attached to the plug by a hollow tube and springs, which at low flow rates locate the piston. When flow increases sufficiently pressure increases and urges the piston upwards. A magnetic portion of tube actuates a succession of proximity switches to indicate flow rate. (author)

  16. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  17. CPAP Tips

    Medline Plus

    Full Text Available ... make your opinion count. Sign in Loading... Loading... Transcript The interactive transcript could not be loaded. Loading... ... Dan Uses CPAP - Duration: 4:17. Harvard Medical School 7,950 views 4:17 Tips for building ...

  18. CPAP Tips

    Science.gov (United States)

    ... make your opinion count. Sign in Loading... Loading... Transcript The interactive transcript could not be loaded. Loading... ... Dan Uses CPAP - Duration: 4:17. Harvard Medical School 7,950 views 4:17 Tips for building ...

  19. Tipping Point

    Medline Plus

    Full Text Available ... fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash format. Almost ... accidents involving young children and furniture, appliance and tv tip-overs. The force of a large television ...

  20. Tipping Point

    Medline Plus

    Full Text Available ... impact can kill a child or cause severe injuries. About 16,000 (mostly young children) were treated in emergency rooms for tip-over related injuries in 2006, that’s about four times more injuries ...

  1. Tipping Point

    Medline Plus

    Full Text Available ... appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch ... reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The force of ...

  2. Tipping Point

    Medline Plus

    Full Text Available ... third story of a building. That kind of impact can kill a child or cause severe injuries. ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit ...

  3. Accidental Bowel Leakage

    Science.gov (United States)

    ... nerve stimulation, injections, and surgery. What types of lifestyle changes can help treat accidental bowel leakage? Having ... Journal Clinical Updates Practice Management Coding Health Info Technology Professional Liability Managing Your Practice Patient Safety & Quality ...

  4. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Transjugular Intrahepatic Portosystemic Shunt (TIPS) Transjugular ... in the portal vein system. This pressure buildup can cause blood to flow backward from the liver ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... physician will numb an area just above your right collarbone with a local anesthetic . A very small ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose ...

  8. Convectively Dominated Heparin Leakage From Multiple Catheter Designs: An In Vitro Experimental Study.

    Science.gov (United States)

    Barbour, Michael Coleman; Gow, Kenneth W; Aliseda, Alberto

    2018-03-16

    Central venous catheters (CVCs) are routinely filled with a heparin lock while not in use to avoid thrombus formation near the tip. However, heparin leakage is known to occur, and the lock effectiveness remains in question. It was recently shown that convective fluxes from the blood flow in the host vein transport the majority of locking solution away from the tip of hemodialysis catheters immediately after instillation. Combined with the low diffusivity of heparin, this results in concentrations of heparin at the catheter tip that are orders of magnitude lower than at instillation for the majority of the interdialytic phase, diminishing the antithrombotic effectiveness of the lock. In this study, heparin losses from three different CVCs with different tip designs are measured in a pulsatile flow loop. Planar laser-induced fluorescence and particle image velocimetry measurements of heparin concentration and fluid velocity are recorded downstream of the catheters and combined to evaluate heparin losses from each of the different catheter designs. Additionally, locking solution losses are measured from one catheter (Hickman) subjected to three different flow conditions. Heparin losses are shown to depend weakly on flow condition but be highly dependent on catheter design. Convective losses from the Hickman catheter, with no side holes, are minimal (1-2%), although losses from the other two catheter types, both with a number of side holes, are significantly higher (7%). These results indicate the potential to maintain a high concentration of locking solution during the interdialytic phase with proper catheter design, particularly focusing on side hole distribution and shape.

  9. Effect of tip clearance on wall shear stress of an axial LVAD

    Science.gov (United States)

    Sarath, S.; Vikas, R.

    2017-09-01

    Wall shear stress is a crucial parameter used for blood damage analysis, and typically a value of 400 Pa is set as a limit. Tip clearance is a major factor contributing to hemolysis and pump efficiency. In this study, different tip gap configurations are used to analyse the wall shear stress developed on the blade surface of a constant thickness blade design, and a varying thickness blade design using CFD analysis. It was found that, for a particular geometry, as the clearance gap reduces, flow rate over the high wall shear stress area decreases even though the high wall shear stress span is found to extend. For each design, the optimum clearance gap is iteratively attained, keeping the maximum WSS as a limiting factor. Thus a better pump designs is obtained, whose leakage flow patterns are lower than that of the initial design, hence also leading to higher pump efficiency.

  10. Tipping Point

    Medline Plus

    Full Text Available ... 24 hours a day. For young children whose home is a playground, it’s the best way to prevent a tip-over tragedy. Share Post Facebook Twitter ... Security, and Legal Notice | Accessibility Policy | Open Government @ CPSC | ...

  11. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ... Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign ...

  12. Three-dimensional analysis of internal flow characteristics in the injection nozzle tip of direct-injection diesel engines; Sanjigen suchi kaiseki ni yoru DI diesel kikan no nenryo funsha nozzle nai ryudo tokusei no kaimei

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H.; Matsui, Y.; Kimura, S. [Nissan Motor Co. Ltd. Tokyo (Japan)

    1997-10-01

    To reduce the exhaust emissions and fuel consumption of direct-injection diesel engines, it is essential to optimize the fuel injection equipment closely related to combustion and emission characteristics. In this study, three-dimensional computation has been applied to investigate the effects of the injection nozzle specifications (e.g., sac volume, round shape at the inlet of the nozzle hole) and needle tip deviation on internal flow characteristics. The computational results revealed that the effects of the nozzle specifications and needle tip deviation with a smaller needle lift on internal flow characteristics and a general approach to optimize the injection nozzle specifications were obtained. 3 refs., 10 figs., 1 tab.

  13. Wing Tip Drag Reduction at Nominal Take-Off Mach Number: An Approach to Local Active Flow Control with a Highly Robust Actuator System

    Directory of Open Access Journals (Sweden)

    Matthias Bauer

    2016-10-01

    Full Text Available This paper discusses wind tunnel test results aimed at advancing active flow control technology to increase the aerodynamic efficiency of an aircraft during take-off. A model of the outer section of a representative civil airliner wing was equipped with two-stage fluidic actuators between the slat edge and wing tip, where mechanical high-lift devices fail to integrate. The experiments were conducted at a nominal take-off Mach number of M = 0.2. At this incidence velocity, separation on the wing section, accompanied by increased drag, is triggered by the strong slat edge vortex at high angles of attack. On the basis of global force measurements and local static pressure data, the effect of pulsed blowing on the complex flow is evaluated, considering various momentum coefficients and spanwise distributions of the actuation effort. It is shown that through local intensification of forcing, a momentum coefficient of less than c μ = 0.6 % suffices to offset the stall by 2.4°, increase the maximum lift by more than 10% and reduce the drag by 37% compared to the uncontrolled flow.

  14. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  15. Tip enhancement

    CERN Document Server

    Kawata, Satoshi

    2007-01-01

    This book discusses the recent advances in the area of near-field Raman scattering, mainly focusing on tip-enhanced and surface-enhanced Raman scattering. Some of the key features covered here are the optical structuring and manipulations, single molecule sensitivity, analysis of single-walled carbon nanotubes, and analytic applications in chemistry, biology and material sciences. This book also discusses the plasmonic materials for better enhancement, and optical antennas. Further, near-field microscopy based on second harmonic generation is also discussed. Chapters have been written by some of the leading scientists in this field, who present some of their recent work in this field.·Near-field Raman scattering·Tip-enhanced Raman spectroscopy·Surface-enhanced Raman spectroscopy·Nano-photonics·Nanoanalysis of Physical, chemical and biological materials beyond the diffraction limits·Single molecule detection

  16. A simple electrochemical methodology for evaluation of the velocity of electroosmotic flow at the tip of polarized microcapillary

    Czech Academy of Sciences Publication Activity Database

    Silver, Barry Richard; Holub, Karel; Mareček, Vladimír

    2015-01-01

    Roč. 156, FEB 2015 (2015), s. 316-320 ISSN 0013-4686 R&D Projects: GA ČR GA13-04630S Institutional support: RVO:61388955 Keywords : ion transport * electroosmotic flow * AC impendance Subject RIV: CG - Electrochemistry Impact factor: 4.803, year: 2015

  17. Electro-hydrodynamics and kinetic modelling of polluted air flow activated by multi-tip-to-plane corona discharge

    Science.gov (United States)

    Meziane, M.; Eichwald, O.; Sarrette, J. P.; Ducasse, O.; Yousfi, M.; Marchal, F.

    2013-04-01

    The present paper is devoted to the 2D simulation of an Atmospheric Corona Discharge Reactor (ACDR) involving 10 pins powered by a DC high voltage and positioned 7 mm above a grounded metallic plane. The corona reactor is periodically crossed by thin mono filamentary streamers with a natural repetition frequency of some tens of kHz. The simulation involves the electro-dynamic, chemical kinetic, and neutral gas hydrodynamic phenomena that influence the kinetics of the chemical species transformation. Each discharge stage (including the primary and the secondary streamers development and the resulting thermal shock) lasts about one hundred nanoseconds while the post-discharge stages occurring between two successive discharge phases last one hundred microseconds. The ACDR is crossed by a lateral air flow including 400 ppm of NO. During the considered time scale of 10 ms, one hundred discharge/post-discharge cycles are simulated. The simulation involves the radical formation and thermal exchange between the discharges and the background gas. The results show how the successive discharges activate the flow gas and how the induced turbulence phenomena affect the redistribution of the thermal energy and the chemical kinetics inside the ACDR.

  18. A coupled approach for the three-dimensional simulation of pipe leakage in variably saturated soil

    Science.gov (United States)

    Peche, Aaron; Graf, Thomas; Fuchs, Lothar; Neuweiler, Insa

    2017-12-01

    In urban water pipe networks, pipe leakage may lead to subsurface contamination or to reduced waste water treatment efficiency. The quantification of pipe leakage is challenging due to inaccessibility and unknown hydraulic properties of the soil. A novel physically-based model for three-dimensional numerical simulation of pipe leakage in variably saturated soil is presented. We describe the newly implemented coupling between the pipe flow simulator HYSTEM-EXTRAN and the groundwater flow simulator OpenGeoSys and its validation. We further describe a novel upscaling of leakage using transfer functions derived from numerical simulations. This upscaling enables the simulation of numerous pipe defects with the benefit of reduced computation times. Finally, we investigate the response of leakage to different time-dependent pipe flow events and conclude that larger pipe flow volume and duration lead to larger leakage while the peak position in time has a small effect on leakage.

  19. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  20. On open and closed tips of bunsen burner flames

    Science.gov (United States)

    Kozlovsky, G.; Sivashinsky, G. I.

    1994-04-01

    An adiabatic, constant-density reaction-diffusion-advection model for the Bunsen burner flame tip is studied numerically. It is shown that for Lewis numbers exceeding unity the reaction rate and flame speed gradually increase toward the flame tip. For small Lewis numbers the picture is quite different. The reaction rate drops near the tip. In spite of this the flame survives and, moreover, manages to consume all the fuel supplied to the reaction zone. There is no leakage of the fuel through the front. The flame speed varies nonmonotonously along the front from gradual reduction to steep increase near the tip.

  1. Prom Health and Safety Tips

    Science.gov (United States)

    ... Autumn Tips Camping Tips Family Reunions Gardening Tips Halloween Tips Healthy Halloween Prom Tips Spring Break Valentine Tips Winter Holiday ... Breast Cancer Assess Your Relationships Be Safe on Halloween Be Smoke-Free Check Alarm Batteries Know Your ...

  2. The role of tip clearance in high-speed fan stall

    Energy Technology Data Exchange (ETDEWEB)

    Adamczyk, J.J. (NASA Lewis Research Center, Cleveland, OH (United States)); Celestina, M.L. (Sverdrup Tech., Inc., Cleveland, OH (United States)); Greitzer, E.M. (Massachusetts Institute of Technology, Cambridge, MA (United States))

    1993-01-01

    A numerical experiment has been carried out to define the near-stall casing endwall flow field of a high-speed fan rotor. The experiment used a simulation code incorporating a simple clearance model, whose calibration is presented. The results of the simulation show that the interaction of the tip leakage vortex and the in-passage shock plays a major role in determining the fan flow range. More specifically, the computations imply that it is the area increase of this vortex as it passes through the in-passage shock that is the source of the blockage associated with stall. In addition, for fans of this type, it is the clearance over the forward portion of the fan blade that controls the flow processes leading to stall.

  3. Tips for Daily Living

    Science.gov (United States)

    ... Tips and Gadgets for Daily Activities Dressing Tips Shopping Tips Modifying the Bathroom Driving After Stroke Medication ... and resources. Find a group in your area . Online Support If there is not a support group ...

  4. Flows correlation of the Tuxtlas, Veracruz volcanic field. Dating by TL of ceramics found in leakages of the San Martin volcano

    International Nuclear Information System (INIS)

    Ramirez, A.; Schaaf, P.; Espindola, J.M.; Zamora, A.

    2006-01-01

    In this work the age estimation carried out to archaeological ceramics found inside the spills and one ash deposit both of the San Martin volcano. The technique used for its processing was that of fine grain (4-11 μm). The paleodosis it was calculated using the additive method for the determination of the equivalent dose (Q) and the regenerative method for the determination of the factor by supralineality (l). The samples of ceramic were processed like total sample. In the case of the geologic sample (ash sample) one carries out the separation of minerals in particular glasses at 95% of purity. For the determination of the annual dose rate its were carried out in the place of sampling measurements with a gamma spectrometry equipment, with it the determinations of Uranium, thorium and potassium were obtained, besides the cosmic contribution. Once having both elements (paleodosis and annual dose rate) it was calculated the age of the samples and consequently of the flows, which were stratigraphically correlated. (Author)

  5. Investigations of leakage mechanisms and its influences on a micro swing engine considering rarefaction effects

    International Nuclear Information System (INIS)

    Zhou, Xiong; Zhang, Zhenyu; Kong, Wenjun; Du, Ning

    2016-01-01

    Highlights: • Mechanisms of the leakage flow in different flow regimes have been studied. • The leakage flow regime and patterns in the micro swing engine are presented. • Slip on the walls has a larger effect on leakage flow with decreasing the gap. • Rarefaction effects on the engine performance have been investigated. - Abstract: Considering rarefaction effects, this paper investigated mechanisms of the clearance leakage and its influences on a micro swing engine for the micro power generation by employing three different flow models named as discrete velocity direction (DVD) model, Navier-Stokes equations with slip boundary conditions (NS-slip) and no-slip boundary conditions (NS-no slip). Using the DVD model, this paper firstly studied leakage mechanisms of a micro Couette-Poisueille flow. Factors which control the leakage in different regimes were obtained. Furthermore, the system-level predictions of the clearance leakage in the micro swing engine have been conducted by solving the Navier-Stokes equations. The leakage flow regime, patterns and characteristics were presented. Results by NS-slip and NS-no slip were compared to study the rarefaction effects. Finally, investigations of the engine size and the gap height on the engine performance have been conducted. The significance of the leakage in different engine size regimes was presented, and the results show that rarefaction effects affect the indicated thermal efficiency greatly with the decrease of the engine size scale.

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver and reduces abnormally high blood pressure in the veins of the stomach, esophagus, bowel and liver, reducing the risk of bleeding from enlarged veins across the esophagus ...

  7. Climate Policy and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the effects of the EU emissions trading scheme on the aluminium sector (i.e. competitiveness loss and carbon leakage). With its very high electricity intensity, primary aluminium stands out in the heavy industry picture: a sector whose emissions are not capped in the present EU ETS, European aluminium smelters still stand to lose profit margins and, possibly, market shares, as electricity prices increase following CO2 caps on generators' emissions - the famous pass-through of CO2 prices into electricity prices. The analysis includes a method of quantification of this issue, based on two indicators: profit margins and trade flows. As the EU is at the forefront of such policy, the paper provides policy messages to all countries on how trade exposed energy-intensive industries can be 'moved' by carbon constraint. This also is a contentious topic in Australia, Japan, New Zealand, and the US, where ambitious climate policies -- including cap-and-trade systems -- are currently debated.

  8. Multifamily Envelope Leakage Model

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, Omari [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Griffiths, Dianne [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-05-08

    “The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deter program participants, and dissuade them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.” This statement found in a 2012 report by Heschong Mahone Group for several California interests emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing—the more appropriate test for assessing energy savings opportunities—could easily be six times that, and that’s only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. This research seeks to provide an algorithm for predicting the guarded blower door test result based upon a single, total blower door test.

  9. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  10. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

  11. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  12. The role of tip clearance in high-speed fan stall

    Science.gov (United States)

    Adamczyk, J. J.; Celestina, M. L.; Greitzer, E. M.

    1991-01-01

    A numerical experiment has been carried out to define the near-stall casing endwall flowfield of a high-speed fan rotor. The experiment used a simulation code incorporating a simple clearance model, whose calibration is presented. The results of the simulation show that the interaction of the tip leakage vortex and the in-pasage shock plays a major role in determining the fan flow range. More specifically, the computations imply that it is the area increase of this vortex as it passes through the in-passage shock, which is the source of the blockage associated with stall. In addition, for fans of this type, it is the clearance over the forward portion of the fan blade which controls the flow processes leading to stall.

  13. Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis

    International Nuclear Information System (INIS)

    Server, Andres; Nakstad, Per H.; Orheim, Tone E.D.; Graff, Bjoern A.; Josefsen, Roger; Kumar, Theresa

    2011-01-01

    Conventional magnetic resonance (MR) imaging has limited capacity to differentiate between glioblastoma multiforme (GBM) and metastasis. The purposes of this study were: (1) to compare microvascular leakage (MVL), cerebral blood volume (CBV), and blood flow (CBF) in the distinction of metastasis from GBM using dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging (DSC-MRI), and (2) to estimate the diagnostic accuracy of perfusion and permeability MR imaging. A prospective study of 61 patients (40 GBMs and 21 metastases) was performed at 3 T using DSC-MRI. Normalized rCBV and rCBF from tumoral (rCBVt, rCBFt), peri-enhancing region (rCBVe, rCBFe), and by dividing the value in the tumor by the value in the peri-enhancing region (rCBVt/e, rCBFt/e), as well as MVL were calculated. Hemodynamic and histopathologic variables were analyzed statistically and Spearman/Pearson correlations. Receiver operating characteristic curve analysis was performed for each of the variables. The rCBVe, rCBFe, and MVL were significantly greater in GBMs compared with those of metastases. The optimal cutoff value for differentiating GBM from metastasis was 0.80 which implies a sensitivity of 95%, a specificity of 92%, a positive predictive value of 86%, and a negative predictive value of 97% for rCBVe ratio. We found a modest correlation between rCBVt and rCBFt ratios. MVL measurements in GBMs are significantly higher than those in metastases. Statistically, both rCBVe, rCBVt/e and rCBFe, rCBFt/e were useful in differentiating between GBMs and metastases, supporting the hypothesis that perfusion MR imaging can detect infiltration of tumor cells in the peri-enhancing region. (orig.)

  14. Investigation of Unsteady Flow Behavior in Transonic Compressor Rotors with LES and PIV Measurements

    Science.gov (United States)

    Hah, Chunill; Voges, Melanie; Mueller, Martin; Schiffer, Heinz-Peter

    2009-01-01

    In the present study, unsteady flow behavior in a modern transonic axial compressor rotor is studied in detail with large eddy simulation (LES) and particle image velocimetry (PIV). The main purpose of the study is to advance the current understanding of the flow field near the blade tip in an axial transonic compressor rotor near the stall and peak-efficiency conditions. Flow interaction between the tip leakage vortex and the passage shock is inherently unsteady in a transonic compressor. Casing-mounted unsteady pressure transducers have been widely applied to investigate steady and unsteady flow behavior near the casing. Although many aspects of flow have been revealed, flow structures below the casing cannot be studied with casing-mounted pressure transducers. In the present study, unsteady velocity fields are measured with a PIV system and the measured unsteady flow fields are compared with LES simulations. The currently applied PIV measurements indicate that the flow near the tip region is not steady even at the design condition. This self-induced unsteadiness increases significantly as the compressor rotor operates near the stall condition. Measured data from PIV show that the tip clearance vortex oscillates substantially near stall. The calculated unsteady characteristics of the flow from LES agree well with the PIV measurements. Calculated unsteady flow fields show that the formation of the tip clearance vortex is intermittent and the concept of vortex breakdown from steady flow analysis does not seem to apply in the current flow field. Fluid with low momentum near the pressure side of the blade close to the leading edge periodically spills over into the adjacent blade passage. The present study indicates that stall inception is heavily dependent on unsteady behavior of the flow field near the leading edge of the blade tip section for the present transonic compressor rotor.

  15. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    Science.gov (United States)

    Shin, K. W.; Andersen, P.

    2015-12-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached eddy simulations (DES) are made for cavitating flows on three tip- modified propellers, of which one is a reference propeller having an experimental result from a cavitation tunnel test with a hull model, and the other two are modified from the reference propeller by altering the blade tip loading. DES results have been validated against the experiment in terms of sheet and cloud cavitation. In DES, non-uniform hull wake is modelled by using the inlet flow and momentum sources instead of including a hull model. A 4-bladed Kappel propeller with a smooth tip bending towards the suction side is used as the reference propeller. For the reference propeller, sheet cavitation extends over a whole chord length in the hull wake peak. As the blade gets out of the wake peak, the rear part of sheet cavity is detached in a form of cloud cavitation. For the reference propeller, the tip pitch reduction from the maximum is about 35%. When decreasing the tip pitch reduction to 10%, tip vortex cavitation is formed and cloud cavitation is significantly weakened. When increasing the tip pitch reduction to 60%, sheet cavitation slightly moves to inner radii and cloud cavitation grows larger.

  16. Control of Leakage in the Triaxial Test

    Science.gov (United States)

    1964-03-01

    greased and tightly compressed by the bonnet nut (see Fig. H-10). The rates of leakage of all valves that are sealed by O-Rings are compared in Table 8-5...34 H-10 6 3 Klinger(packing boiled in distilled water and greased and bonnet nut screwed down as far as It would go) 0.20 45 123 2.0 0.05 11...measured a total flow of only 20 mm3 in 10 days through either a silicone-oil-soaked or an unsoaked mem- brane of the type he used. This is about the

  17. Healthy Vision Tips

    Science.gov (United States)

    ... for Kids >> Healthy Vision Tips Listen All About Vision About the Eye Ask a Scientist Video Series ... Links to More Information Optical Illusions Printables Healthy Vision Tips Healthy vision starts with you! Use these ...

  18. Study on the annular leakage-flow-induced vibrations. 2nd Report. Stability analysis and experiments for translationally and rotationally coupled two-degree-of-freedom systems; Kanjo sukimaryu reiki shindo ni kansuru kenkyu. 2. heishin kaiten 2 jiyudo renseikei no anteisei kaiseki oyobi jikken

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.W. [Hitachi, Ltd., Tokyo (Japan); Kaneko, S. [The University of Tokyo, Tokyo (Japan); Hayama, S. [Toyama Prefectural University, Toyama (Japan)

    1999-07-25

    In this study, the stability of annular leakage-flow-induced vibrations was investigated theoretically and experimentally for a translationally and rotationally coupled two-degree-of-freedom system. The critical flow rate was both theoretically and experimentally obtained as a function of the passage increment ratio and the eccentricity of the passage. A good agreement between the theoretical and experimental results was obtained. It was discovered both theoretically and from the experiments that instability will occur in the case of a divergent passage: the eccentricity of the passage lowers the stability of the systems. (author)

  19. Digestive Health Tips

    Science.gov (United States)

    ... Home / Digestive Health Topic / Digestive Health Tips Digestive Health Tips Basics 10 Tips on Belching, Bloating, and Flatulence Belching is caused by swallowed air from: Eating or drinking too fast Poorly fitting dentures; not chewing food completely Carbonated beverages Chewing gum or sucking on ...

  20. Indian Ocean sources of Agulhas leakage

    Science.gov (United States)

    Durgadoo, Jonathan V.; Rühs, Siren; Biastoch, Arne; Böning, Claus W. B.

    2017-04-01

    We examine the mean pathways, transit timescales, and transformation of waters flowing from the Pacific and the marginal seas through the Indian Ocean (IO) on their way toward the South Atlantic within a high-resolution ocean/sea-ice model. The model fields are analyzed from a Lagrangian perspective where water volumes are tracked as they enter the IO. The IO contributes 12.6 Sv to Agulhas leakage, which within the model is 14.1 ± 2.2 Sv, the rest originates from the South Atlantic. The Indonesian Through-flow constitutes about half of the IO contribution, is surface bound, cools and salinificates as it leaves the basin within 10-30 years. Waters entering the IO south of Australia are at intermediate depths and maintain their temperature-salinity properties as they exit the basin within 15-35 years. Of these waters, the contribution from Tasman leakage is 1.4 Sv. The rest stem from recirculation from the frontal regions of the Southern Ocean. The marginal seas export 1.0 Sv into the Atlantic within 15-40 years, and the waters cool and freshen on-route. However, the model's simulation of waters from the Gulfs of Aden and Oman are too light and hence overly influenced by upper ocean circulations. In the Cape Basin, Agulhas leakage is well mixed. On-route, temperature-salinity transformations occur predominantly in the Arabian Sea and within the greater Agulhas Current region. Overall, the IO exports at least 7.9 Sv from the Pacific to the Atlantic, thereby quantifying the strength of the upper cell of the global conveyor belt.

  1. The TIPS Liquidity Premium

    DEFF Research Database (Denmark)

    Andreasen, Martin Møller; Christensen, Jens H.E.; Simon Riddell, Simon

    We introduce an arbitrage-free term structure model of nominal and real yields that accounts for liquidity risk in Treasury inflation-protected securities (TIPS). The novel feature of our model is to identify liquidity risk from individual TIPS prices by accounting for the tendency that TIPS, like...... most fixed-income securities, go into buy-and-hold investors' portfolios as time passes. We find a sizable and countercyclical TIPS liquidity premium, which greatly helps our model in matching TIPS prices. Accounting for liquidity risk also improves the model's ability to forecast inflation and match...

  2. Arctic climate tipping points.

    Science.gov (United States)

    Lenton, Timothy M

    2012-02-01

    There is widespread concern that anthropogenic global warming will trigger Arctic climate tipping points. The Arctic has a long history of natural, abrupt climate changes, which together with current observations and model projections, can help us to identify which parts of the Arctic climate system might pass future tipping points. Here the climate tipping points are defined, noting that not all of them involve bifurcations leading to irreversible change. Past abrupt climate changes in the Arctic are briefly reviewed. Then, the current behaviour of a range of Arctic systems is summarised. Looking ahead, a range of potential tipping phenomena are described. This leads to a revised and expanded list of potential Arctic climate tipping elements, whose likelihood is assessed, in terms of how much warming will be required to tip them. Finally, the available responses are considered, especially the prospects for avoiding Arctic climate tipping points.

  3. Low leakage mechanical joint development

    International Nuclear Information System (INIS)

    Crago, W.A.

    1976-01-01

    As a consequence of the development programs described, certain recommendatons for design of mechanial joints have been proposed. These include: 1. Spiral wound gaskets filled with chrysotile asbestos are adequate for primary heat transport system fluid conditions. 2. Spiral wound gaskets should be seated under a stress of 110 to 125 MPa for low leakage performance. 3. Load maintenance, while perhaps reducing leakage, introduces more complex hardware, and is of unproven benefit. 4. Uniform circumferential load application requires the use of hydraulic stud tensioners to ensure satisfactory performance from large size mechanical joints. (author)

  4. Characterization of CO2 leakage into the freshwater body

    DEFF Research Database (Denmark)

    Singh, Ashok; Delfs, Jens Olaf; Shao, H.

    2013-01-01

    , the leakage into a multi-layered fractured saline aquifer is modelled with a numerical model regarding its pressure build-up process. The investigation is performed with the non-isothermal compositional fluid flow module implemented by authors in the OpenGeoSys (OGS) software for geotechnical applications....

  5. Experimental investigation on air leakage characteristics of containments

    International Nuclear Information System (INIS)

    Hyungtae Kim; Namso Cho; Youngsun Choun; Namsik Kim

    2005-01-01

    Facilities such as nuclear power plants have containments as atomic reactor which are subjected to high internal pressure. The internal pressure induces tensile stress in the containments. The tensile stress can cause generation and propagation of cracks through which the gas contaminated radioactively may leak. Supposing that a potential leakage accident happened, an experimental study on air leakage characteristics of containments was carried out. Two reinforced concrete specimens which reflect a wall of the containment were manufactured. Then the specimens were subjected to tensile load to generate cracks and air penetration tests were performed. During the air leakage test, the air pressure of inlet and outlet, the flow rate of outlet and the sum of crack widths were measured. The individual factors of the specific crack shape, the wall roughness and the flow coefficient, could be estimated from these experimental data. The factors are expressed as functions in terms of the sum of crack widths by regression analysis. The measured flow rates were compared with the predictive values obtained using the regression curves. Then flow rates according to pressure gradient and crack width were estimated. It was verified that the predicted flow rates agree with the measured flow rates statistically, that is, the estimated functions predicting the wall roughness and the flow coefficient are suitable. Once the sum of crack widths and inlet pressure of concrete wall are known, thus, the air flow rate can be predicted. The relationship among crack width, pressure and flow rate will serve as a criterion for air leakage characteristics of containments. (authors)

  6. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  7. Numerical Simulation of LVAD Inflow Cannulas with Different Tip

    Directory of Open Access Journals (Sweden)

    Guang-Mao Liu

    2012-01-01

    Full Text Available The tip structure of LVAD inflow cannula is one of major factors to lead adverse events such as thrombosis and suction leading to obstruction. In this research, four kinds of tips that had been used in inflow cannulas were selected and designed. The flow field of the four inflow cannulas inserted into the apex of left ventricle (LV was numerically computed by computational fluid dynamics. The flow behavior was analyzed in order to compare the blood compatibility and suction in left ventricle and cannulas after the inflow cannulas with different tips were inserted to the apex of LV. The results showed that the cannula tip structure affected the LVAD performance. Among these four cannulas, the trumpet-tipped inflow cannula owned the best performance in smooth flow velocity distribution without backflow or low-velocity flow so that it was the best in blood compatibility. Nevertheless, the caged tipped cannula was the worst in blood compatibility. And the blunt-tipped and beveled tipped inflow cannulas may obstruct more easily than trumpet and caged tipped inflow cannulas because of their shape. The study indicated that the trumpet tip was the most preferable for the inflow cannula of long-term LVAD.

  8. Leakage tests of wall segments of reactor containments

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.; MacGregor, J.G.

    1979-10-01

    Two prestressed concrete wall segments simulating portions of containment walls were loaded by axial tensile forces to cause cracking of the concrete. At each load increment air pressure was applied in steps up to 21 psi to one side of the segment and the rate of leakage of air through the cracked concrete section was measured. A theoretical equation for the flow of air through concrete cracks is developed and the results from one leakage test are used to determine the dimensionless constant required for this equation. (author)

  9. Instrumentation with real-world considerations for integrated leakage testing

    International Nuclear Information System (INIS)

    Gibson, L.D.; Carp, J.

    1982-01-01

    In measuring leakage of containment structures, the precise determination of pressure, temperature, dewpoint and flow rate parameters is of critical importance. The change in these values over a specified test period provides the basis for computation of the leakage for a given pressurized volume. The performance of an Integrated Leak Rate Test (ILRT) on the containment is generally a critical path event that must be planned far in advance. The very nature of the test requires rapid, efficient acquisition and processing of data for determination, and sometimes correction, of leakages. Equipment selection is an important consideration which can directly affect the outcome of the test. The intent of this paper is to shed some light on the concerns of choosing an instrumentation package for the ILRT

  10. Evaluation of isolation valve leakage in alternate charging piping

    International Nuclear Information System (INIS)

    Strauch, P.L.; Roarty, D.H.; Brice-Nash, R.L.

    1995-01-01

    The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report ''Thermal Stratification, Cycling, and Striping (TASCS),'' March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided

  11. Tipping the balance: robustness of tip cell selection, migration and fusion in angiogenesis.

    Directory of Open Access Journals (Sweden)

    Katie Bentley

    2009-10-01

    Full Text Available Vascular abnormalities contribute to many diseases such as cancer and diabetic retinopathy. In angiogenesis new blood vessels, headed by a migrating tip cell, sprout from pre-existing vessels in response to signals, e.g., vascular endothelial growth factor (VEGF. Tip cells meet and fuse (anastomosis to form blood-flow supporting loops. Tip cell selection is achieved by Dll4-Notch mediated lateral inhibition resulting, under normal conditions, in an interleaved arrangement of tip and non-migrating stalk cells. Previously, we showed that the increased VEGF levels found in many diseases can cause the delayed negative feedback of lateral inhibition to produce abnormal oscillations of tip/stalk cell fates. Here we describe the development and implementation of a novel physics-based hierarchical agent model, tightly coupled to in vivo data, to explore the system dynamics as perpetual lateral inhibition combines with tip cell migration and fusion. We explore the tipping point between normal and abnormal sprouting as VEGF increases. A novel filopodia-adhesion driven migration mechanism is presented and validated against in vivo data. Due to the unique feature of ongoing lateral inhibition, 'stabilised' tip/stalk cell patterns show sensitivity to the formation of new cell-cell junctions during fusion: we predict cell fates can reverse. The fusing tip cells become inhibited and neighbouring stalk cells flip fate, recursively providing new tip cells. Junction size emerges as a key factor in establishing a stable tip/stalk pattern. Cell-cell junctions elongate as tip cells migrate, which is shown to provide positive feedback to lateral inhibition, causing it to be more susceptible to pathological oscillations. Importantly, down-regulation of the migratory pathway alone is shown to be sufficient to rescue the sprouting system from oscillation and restore stability. Thus we suggest the use of migration inhibitors as therapeutic agents for vascular

  12. Suppression and control of leakage field in electromagnetic helical microwiggler

    Energy Technology Data Exchange (ETDEWEB)

    Ohigashi, N. [Kansai Univ., Osaka (Japan); Tsunawaki, Y. [Osaka Sangyo Univ. (Japan); Imasaki, K. [Institute for Laser Technology, Osaka (Japan)] [and others

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  13. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen

    2011-01-01

    hole for administration of drugs, bloods or nutrients into the bloodstream. Even if the UVC light is strongly attenuated during its propagation through the catheter tube a fraction of the UVC launched into the catheter will escape through the exit hole and irradiate the blood. We demonstrate...... by calculations that very small effective doses are exposed to the blood (ca 10(-4) J m(-2) ). This dosage level is very low compared with UVC doses reported from other therapeutic applications. The very short residence time of the blood constituents in the irradiated volume in front of the exit hole is the main...... reason why the UVC exposure to the blood in the catheter application is so low. The very low dose received by the blood through the catheter tip indicated that possible side effects are negligible and makes the UV disinfection technique feasible in a clinical setting....

  14. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  15. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  16. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  17. Electrolyte leakage as an indicator

    Directory of Open Access Journals (Sweden)

    ahmad nezami

    2009-06-01

    Full Text Available In order to evaluate the electrolyte leakage as an indicator of freezing injury in colza (Brassica napus L. genotypes under controlled conditions, a trial carried out at the green house of College of Agriculture, Ferdowsi University of Mashhad. In this study 10 rapeseed genotypes, with 5 temperatures (0, -4, -8, -12 and -16 °C on subplot and acclimation and non acclimation on main plot were evaluated on RCD factorial split plot with two replications. Plants were kept until 3-5 leaf stage in green house condition with 23/16 2 °C (day/night and natural photoperiod. Pots were subjected to acclimation (for three weeks or non acclimation that plants immediately frozen.For acclimation treatment after three weeks freezing was done in thermogradient freezer. The cell membrane integrity was measured through electrolyte leakage and the lethal temperature 50 (LT50 of samples also were determined. There were significant differences (p

  18. Acoustic emission generated by fluid leakage

    International Nuclear Information System (INIS)

    Kim, H.C.

    1987-01-01

    The noise generated by the leaking saturated steam and subcooled water form various sizes of hole has been measured as function of leak rate and stagnation pressure. Acoustic emission (proportinal to root mean sguare voltage) is shown to be proportional to the leak rate and stagnation pressure. A transition of acoustic emission power is observed at the stagnation pressure 0.185 MPa associated with the transition to the critical flow state. Substantially higher acoustic emission power generated by the subcooled water leakage is attributed to the flashing source involving the phase transformation and volume expansion. The relative amplitude of noise spectrum becomes more spiky as the leak rate and stagnation pressure increased. (Author)

  19. Tips in Reading Instruction.

    Science.gov (United States)

    Ediger, Marlow

    Some tips can assist teachers in guiding each pupil to achieve more optimally, with respect to the ability to read well and reading comprehension. Among these 10 specific tips are: (1) teach individualized phonics in context; (2) assist the student to read in proper thought units by covering up words in sentences for clarification; (3) assist…

  20. ADHD: Tips to Try

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español ADHD: Tips to Try KidsHealth / For Teens / ADHD: Tips to Try Print en español TDAH: Consejos que puedes probar ADHD , short for attention deficit hyperactivity disorder , is a ...

  1. Total Telephone Tips.

    Science.gov (United States)

    Corder, Lloyd E.; And Others

    This manual of telephone behavior tips for business and sales professionals offers ways to handle the disgruntled caller and makes suggestions on topics relevant to the telephone. The manual is divided into the following sections and subsections: (1) Common Courtesy (staff tips, answering the telephone, screening calls, transferring calls, taking…

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver). Portal hypertension can also occur in children, although children are much less likely to require a TIPS. ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... vs. risks? What are the limitations of TIPS? What is a Transjugular Intrahepatic Portosystemic Shunt (TIPS)? A ... likely to require a TIPS. top of page What are some common uses of the procedure? A ...

  4. First Aid Tips

    Science.gov (United States)

    ... Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI for Kids » First Aid Tips Listen All About Vision About the Eye ...

  5. Tips for Daily Life

    Science.gov (United States)

    ... chapter Join our online community Tips for Daily Life Coping skills will help you handle day-to- ... challenges, maximize your independence and live a meaningful life with your diagnosis. Accepting changes Creating a coping ...

  6. Toilet training tips

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000944.htm Toilet training tips To use the sharing features on ... and 'pee'. Teaching Your Child to Use the Toilet Once your child is comfortable sitting on the ...

  7. Effects of cavity on leakage loss in straight-through labyrinth seals

    International Nuclear Information System (INIS)

    Zhao, W; Nielsen, T K; Billdal, J T

    2010-01-01

    Labyrinth seals are widely used in rotating fluid machinery, due to its low-cost, simplicity and reliability. A straight-through labyrinth seal consists of a clearance between the stator and rotor, and sometimes cavities which are included on the stator or the rotator side. In this type of seals, making cavities are an effective way to convert turbulence kinetic energy into thermal energy by forming turbulence vortices, thereby reducing pressure difference and leakage flow. In this paper, the effect of cavities on leakage loss in straight-through labyrinth seals are studied by changing cavity dimensions such as depth and length, cavity number and cavity location. The influences of unilateral cavities and bilateral cavities on the leakage loss in straight-through labyrinth seals are also compared. The fluid flow characteristics through straight-through labyrinth seals were obtained by using viscous flow analysis along with a standard k-ωturbulence model. The cavity dimensions and cavity numbers have significant effects on the leakage as well as on the flow pattern in the seal. The bilateral cavity has better leakage performance than the unilateral cavity when cavity dimensions are identical. However, the cavity location shows no significant influences on the leakage flow.

  8. Numerical studies of CO2 and brine leakage into a shallow aquifer through an open wellbore

    Science.gov (United States)

    Wang, Jingrui; Hu, Litang; Pan, Lehua; Zhang, Keni

    2018-03-01

    Industrial-scale geological storage of CO2 in saline aquifers may cause CO2 and brine leakage from abandoned wells into shallow fresh aquifers. This leakage problem involves the flow dynamics in both the wellbore and the storage reservoir. T2Well/ECO2N, a coupled wellbore-reservoir flow simulator, was used to analyze CO2 and brine leakage under different conditions with a hypothetical simulation model in water-CO2-brine systems. Parametric studies on CO2 and brine leakage, including the salinity, excess pore pressure (EPP) and initially dissolved CO2 mass fraction, are conducted to understand the mechanism of CO2 migration. The results show that brine leakage rates increase proportionally with EPP and inversely with the salinity when EPP varies from 0.5 to 1.5 MPa; however, there is no CO2 leakage into the shallow freshwater aquifer if EPP is less than 0.5 MPa. The dissolved CO2 mass fraction shows an important influence on the CO2 plume, as part of the dissolved CO2 becomes a free phase. Scenario simulation shows that the gas lifting effect will significantly increase the brine leakage rate into the shallow freshwater aquifer under the scenario of 3.89% dissolved CO2 mass fraction. The equivalent porous media (EPM) approach used to model the wellbore flow has been evaluated and results show that the EPM approach could either under- or over-estimate brine leakage rates under most scenarios. The discrepancies become more significant if a free CO2 phase evolves. Therefore, a model that can correctly describe the complex flow dynamics in the wellbore is necessary for investigating the leakage problems.

  9. Topological qubit design and leakage

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, R; Slingerland, J K, E-mail: robert.ainsworth@nuim.ie, E-mail: joost@thphys.nuim.ie [Department of Mathematical Physics, National University of Ireland Maynooth, Co. Kildare (Ireland)

    2011-06-15

    We examine how best to design qubits for use in topological quantum computation. These qubits are topological Hilbert spaces associated with small groups of anyons. Operations are performed on these by exchanging the anyons. One might argue that in order to have as many simple single-qubit operations as possible, the number of anyons per group should be maximized. However, we show that there is a maximal number of particles per qubit, namely 4, and more generally a maximal number of particles for qudits of dimension d. We also look at the possibility of having topological qubits for which one can perform two-qubit gates without leakage into non-computational states. It turns out that the requirement that all two-qubit gates are leakage free is very restrictive and this property can only be realized for two-qubit systems related to Ising-like anyon models, which do not allow for universal quantum computation by braiding. Our results follow directly from the representation theory of braid groups, which implies that they are valid for all anyon models. We also make some remarks about generalizations to other exchange groups.

  10. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  11. Study on detecting leachate leakage of municipal solid waste landfill site.

    Science.gov (United States)

    Liu, Jiangang; Cao, Xianxian; Ai, Yingbo; Zhou, Dongdong; Han, Qiting

    2015-06-01

    The article studies the detection of the leakage passage of leachate in a waste landfill dam. The leachate of waste landfill has its own features, like high conductivity, high chroma and an increasing temperature, also, the horizontal flow velocity of groundwater on the leakage site increases. This article proposes a comprehensive tracing method to identify the leakage site of an impermeable membrane by using these features. This method has been applied to determine two leakage sites of the Yahu municipal solid waste landfill site in Pingshan District, Shenzhen, China, which shows that there are two leachate leakage passages in the waste landfill dam A between NZK-2 and NZK-3, and between NZK-6 and NZK-7. © The Author(s) 2015.

  12. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... {\\em Leakage resilient oblivious transfer.} We present the first construction for 1-out-of-2 oblivious transfer with security against leakage of a constant fraction of the honest party's memory. Our protocol is based on the OT construction presented by Peikert et al.~\\cite{PeikertVW08}. \\item {\\em...... Leakage resilient Yao's Garbled Circuit~\\cite{Yao82}.} We provide the first general construction for secure two-party computation and show how to adapt the proof from~\\cite{LP09} of Yao's protocol into the leakage resilient setting. Our result holds for a restricted set of functions due to technicalities...

  13. A method to investigate inter-aquifer leakage using hydraulics and multiple environmental tracers

    Science.gov (United States)

    Priestley, Stacey; Love, Andrew; Wohling, Daniel; Post, Vincent; Shand, Paul; Kipfer, Rolf; Tyroller, Lina

    2016-04-01

    Informed aquifer management decisions regarding sustainable yields or potential exploitation require an understanding of the groundwater system (Alley et al. 2002, Cherry and Parker 2004). Recently, the increase in coal seam gas (CSG) or shale gas production has highlighted the need for a better understanding of inter-aquifer leakage and contaminant migration. In most groundwater systems, the quantity or location of inter-aquifer leakage is unknown. Not taking into account leakage rates in the analysis of large scale flow systems can also lead to significant errors in the estimates of groundwater flow rates in aquifers (Love et al. 1993, Toth 2009). There is an urgent need for robust methods to investigate inter-aquifer leakage at a regional scale. This study builds on previous groundwater flow and inter-aquifer leakage studies to provide a methodology to investigate inter-aquifer leakage in a regional sedimentary basin using hydraulics and a multi-tracer approach. The methodology incorporates geological, hydrogeological and hydrochemical information in the basin to determine the likelihood and location of inter-aquifer leakage. Of particular benefit is the analysis of hydraulic heads and environmental tracers at nested piezometers, or where these are unavailable bore couplets comprising bores above and below the aquitard of interest within a localised geographical area. The proposed methodology has been successful in investigating inter-aquifer leakage in the Arckaringa Basin, South Australia. The suite of environmental tracers and isotopes used to analyse inter-aquifer leakage included the stable isotopes of water, radiocarbon, chloride-36, 87Sr/86Sr and helium isotopes. There is evidence for inter-aquifer leakage in the centre of the basin ~40 km along the regional flow path. This inter-aquifer leakage has been identified by a slight draw-down in the upper aquifer during pumping in the lower aquifer, overlap in Sr isotopes, δ2H, δ18O and chloride

  14. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    construction may already suffice to protect against realistic side-channel attacks. In this paper, we show that indeed for simpler constructions leakage-resilience can be obtained when we aim for relaxed security notions where the leakage-functions and/or the inputs to the primitive are chosen non......-adaptively. For example, we show that a three round Feistel network instantiated with a leakage resilient PRF yields a leakage resilient PRP if the inputs are chosen non-adaptively (This complements the result of Dodis and Pietrzak [CRYPTO’10] who show that if a adaptive queries are allowed, a superlogarithmic number...

  15. Small gas leakage rate measuring and monitoring system for spent fuel transport/storage cask

    Energy Technology Data Exchange (ETDEWEB)

    Asano, Ryoji [Hitachi Zosen Corp., Tokyo (Japan); Aritomi, Masanori; Matsuzaki, Mitsuo; Kawa, Tsunemichi

    1997-12-01

    A containment function of transport and/or storage casks of radioactive materials is essential to prevent the materials from being released excessively into the environment. It is not practical for containment tests to measure directly the radioactivity release so that gas volumetric leakage rates are usually assessed and gas pressure decrease or increase method is usually applied. As gas flow model for evaluation, the ISO standards has deleted the concept of choked flow which is adopted by ANSI N14.5. Provided that the choked flow is not adopted to the leakage rate evaluation, the criteria of the test should be severe, and a new leakage rate measuring system with high accuracy and reasonable measuring time is required. Transport casks are often inspected in a temporary cask-storage facility where simultaneous measurement of many casks is required. In a storage cask system, multiple casks are monitored on their containment function during a storage period, and the method for simultaneous monitoring at many points for long term is required. In this study, two kinds of small gas leakage rate measuring systems are developed. One is to measure gas leakage rates directly and is called `flow measuring system`, which can measure gas leakage rate of 10{sup -4} to 10{sup -2} cm{sup 3}/s with high accuracy and short measuring time. The other is to measure the pressure decreasing rate and is called `pressure decreasing rate measuring system`, which can monitor the pressure change at many points simultaneously. (author)

  16. Numerical study of hydrofoil tip vortex fluid field

    Directory of Open Access Journals (Sweden)

    PU Jijun

    2017-01-01

    Full Text Available Three different models,k-ω,DES and LES,are conducted in the analysis of the tip vortex flow field. In order to reduce the discrete error induced by the grid,mesh refinement is applied to the area of the tip vortex core in numerical simulations. The axis and tangential velocities of the tip vortex flow field with no cavitation are calculated,and the calculated velocities agree well with the experimental results. On the basis of this process,the influence of vortex roll-up on the tip vortex pressure filed is discussed,and bubble static equilibrium is proposed by which the tip vortex cavitation inception number is computed.

  17. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  18. Physical Leakage Analysis in Water Distribution Networks By Daily Consumption Curve

    OpenAIRE

    Kılıç, Recep; Cinal, Hüseyin

    2018-01-01

    The curve of daily water consumption in drinkingwater networks provides a lot of information on the physical status of thenetwork. The existing physical leakage rate can be estimated by analyzing thenetwork water consumption curve. Hence, precautions can be taken in order toprevent the physical leakages and water losses. In this study, the minimumnight flow (MNF) that occurs in the determined measurement areas (DMA) in thecurrent drinking water network was examined, and it was attempted to de...

  19. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  20. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice of inform...... and non-timed attacks on the Onion Routing protocol....

  1. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O.; Arena, L.; Griffiths, D.

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  2. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  3. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied......: (i) in each observation the leakage is bounded, (ii) different parts of the computation leak independently, and (iii) the randomness that is used for certain operations comes from a simple (non-uniform) distribution. In contrast to earlier work on leakage resilient circuit compilers, which relied...

  4. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. STUDY 1......, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim...... of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme...

  5. Leakage experiences with 1 MW steam generator

    International Nuclear Information System (INIS)

    Kanamori, A.; Kawara, M.; Sano, A.

    1975-01-01

    An 1 MW steam generator was tested from October, 1971 and completed with the first series of experiments by May, 1972 after 3600 hours of operation. During these tests, unextraordinary heat absorption was experienced in the downcomer region, which led to shortage of heat transfer area to attain the rated steam temperature and to one of the reasons of flow instabilities. The steam generator was disassembled to get test pieces for structure as well as material examinations and then it was reassembled to proceed the second series of tests. Before it was done, a modification was provided to insulate the downcomer region by putting a gas space around the downcomer tube. The gas space was provided by a dual tube and spacers were welded on the inner tube and an end plate was welded on upper parts between the two to seal the gap by means of fillet welding. After the modified steam generator was put into operation, water happened to leak into a sodium side two times through these additional welding spots for the gas insulation. This paper presents operating conditions and behaviors of monitors at the time of the leakages, identifications of leaked spots, an evaluation of causes and a treatment or a precaution for them

  6. Tips from the Classroom.

    Science.gov (United States)

    Wilhelm, Kim Hughes; Leverett, Thomas; Barrett, Rob J.; Chur-Hansen, Anna; Dantas-Whitney, Maria; Zapata, Gabriela; Garcia, Juan Felix

    1998-01-01

    Five articles present tips for rallying English-as-a-Second-Language students to the enterprise of creating context, tools, and language itself. The articles focus on using original dramas created by students, teaching nonnative English-speaking medical students to comprehend their patients' colloquial language, conducting research with native…

  7. Air Travel Health Tips

    Science.gov (United States)

    ... Conditions Prevention and Wellness Staying Healthy Healthy Living Travel Occupational Health First Aid and Injury Prevention Crisis ... MoreDepression in Children and TeensRead MoreBMI Calculator International Travel: Tips for Staying HealthyTexting and DrivingTravel Needs for ...

  8. 10 Data Visualization Tips

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    communicated through the use of design choices. (as indicated in tip 8). 8. Use colour, size, and position to help the reader see what is important. Colour adds emphasis, highlights particular data points, and draws connections between graphs. The hue, value, and intensity of the colour are significant and may have cultural ...

  9. Sports Dehydration Safety Tips

    Science.gov (United States)

    Sports Dehydration Safety Tips Everything you need to know to keep your kids safe from dehydration when playing sports. To keep kids in top ... to stay hydrated by drinking plenty of fluids. Dehydration occurs when a body loses more water than ...

  10. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  11. Spatio-temporal characteristics of Agulhas leakage: a model inter-comparison study

    Science.gov (United States)

    Holton, L.; Deshayes, J.; Backeberg, B. C.; Loveday, B. R.; Hermes, J. C.; Reason, C. J. C.

    2017-04-01

    Investigating the variability of Agulhas leakage, the volume transport of water from the Indian Ocean to the South Atlantic Ocean, is highly relevant due to its potential contribution to the Atlantic Meridional Overturning Circulation as well as the global circulation of heat and salt and hence global climate. Quantifying Agulhas leakage is challenging due to the non-linear nature of this process; current observations are insufficient to estimate its variability and ocean models all have biases in this region, even at high resolution . An Eulerian threshold integration method is developed to examine the mechanisms of Agulhas leakage variability in six ocean model simulations of varying resolution. This intercomparison, based on the circulation and thermohaline structure at the Good Hope line, a transect to the south west of the southern tip of Africa , is used to identify features that are robust regardless of the model used and takes into account the thermohaline biases of each model. When determined by a passive tracer method, 60 % of the magnitude of Agulhas leakage is captured and more than 80 % of its temporal fluctuations, suggesting that the method is appropriate for investigating the variability of Agulhas leakage. In all simulations but one, the major driver of variability is associated with mesoscale features passing through the section. High resolution ({<} 1/10°) hindcast models agree on the temporal (2-4 cycles per year) and spatial (300-500 km) scales of these features corresponding to observed Agulhas Rings. Coarser resolution models ({<} 1/4°) reproduce similar time scale of variability of Agulhas leakage in spite of their difficulties in representing the Agulhas rings properties. A coarser resolution climate model (2°) does not resolve the spatio-temporal mechanism of variability of Agulhas leakage. Hence it is expected to underestimate the contribution of Agulhas Current System to climate variability.

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS. top of page What are some common uses of the procedure? A TIPS is used to ... the scanner by a cord. Some exams may use different transducers (with different capabilities) during a single ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... or bypass, without the risks that accompany open surgery. TIPS is a minimally invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of an effect ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... then placed in this tunnel to keep the pathway open. Patients who typically need a TIPS have ... and stomach. A TIPS procedure involves creating a pathway through the liver that connects the portal vein ( ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and/or hydrothorax (in the chest). Budd-Chiari syndrome , a blockage in one or more veins that ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... What are the limitations of TIPS? What is a Transjugular Intrahepatic Portosystemic Shunt (TIPS)? A transjugular intrahepatic ... taking our brief survey: Survey Do you have a personal story about radiology? Share your patient story ...

  17. A new on-line leakage current monitoring system of ZnO surge arresters

    International Nuclear Information System (INIS)

    Lee, Bok-Hee; Kang, Sung-Man

    2005-01-01

    This paper presents a new on-line leakage current monitoring system of zinc oxide (ZnO) surge arresters. To effectively diagnose the deterioration of ZnO surge arresters, a new algorithm and on-line leakage current detection device, which uses the time-delay addition method, for discriminating the resistive and capacitive currents was developed to use in the aging test and durability evaluation for ZnO arrester blocks. A computer-based measurement system of the resistive leakage current, the on-line monitoring device can detect accurately the leakage currents flowing through ZnO surge arresters for power frequency ac applied voltages. The proposed on-line leakage current monitoring device of ZnO surge arresters is more highly sensitive and gives more linear response than the existing devices using the detection method of the third harmonic leakage currents. Therefore, the proposed leakage current monitoring device can be useful for predicting the defects and performance deterioration of ZnO surge arresters in power system applications

  18. Evaluation of the effects of enameloplasty and air abrasion on sealant micro-leakage.

    Directory of Open Access Journals (Sweden)

    Aliasghar Soleymani

    2014-12-01

    Full Text Available Micro-leakage, one of the major reasons for recurrent decays, may lead to uncontrollable flow of liquids, pulp inflammation and peri-apical pathology. The purpose of this in vitro study was to evaluate micro-leakage of pit and fissure sealants after using three different pit and fissure preparation techniques: 1 acid etching, 2 fissure enameloplasty and acid etching, and 3 air abrasion and acid etching.Sixty-nine extracted sound molars and premolars were randomly divided into three groups (23 samples in each group. Teeth were prepared using one of three occlusal surface treatments. Then the sealant was applied on the occlusal fissures of all teeth. The teeth were thermocycled and stored in normal saline. All teeth were sealed apically and coated with nail varnish and then were immersed in a 2% solution of methylen blue. Two buccolingual sections were made. The surfaces were scored 0 to 3 for the extent of micro-leakage using a stereomicroscope. Data were analyzed by Kruskal- wallis and Dunn procedure.Enameloplasty and acid etching were significantly different regarding micro-leakage (P= 0.016, but no significant difference in micro-leakage was observed between air abrasion and the other methods.Enameloplasty followed by acid etching produced significantly less micro-leakage than the acid etching technique. Air abrasion acid etching was better than the acid etching technique in reducing micro-leakage too.

  19. New Belgian position on containment leakage testing

    International Nuclear Information System (INIS)

    De Boeck, B.

    1986-01-01

    The containment leakage testing requirements (up to now 10 CFR 50 App. J) have recently been reevaluated in Belgium. The criterion for type A tests at half the accident pressure has been strengthened, but the periodicity has been relaxed. New overall leakage test at very low overpressure have been required after each extended cold shutdown period. A few items of the procedure for type A tests have been modified. It is felt that the new requirements improve the safety but also lower the burden of the containment leakage tests. Experimental results from tests performed in 1985 at Tihange reactor and Doel unit 3 are presented

  20. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... liver disease are at greater risk for worsening liver failure after TIPS. If your liver failure is severe, a TIPS may not be the best use and a different procedure may be needed to control your symptoms. ... ordinarily filtered out by the liver. The TIPS may cause too much of these ...

  2. Leakage of CO2 from geologic storage: Role of secondaryaccumulation at shallow depth

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, K.

    2007-05-31

    Geologic storage of CO2 can be a viable technology forreducing atmospheric emissions of greenhouse gases only if it can bedemonstrated that leakage from proposed storage reservoirs and associatedhazards are small or can be mitigated. Risk assessment must evaluatepotential leakage scenarios and develop a rational, mechanisticunderstanding of CO2 behavior during leakage. Flow of CO2 may be subjectto positive feedbacks that could amplify leakage risks and hazards,placing a premium on identifying and avoiding adverse conditions andmechanisms. A scenario that is unfavorable in terms of leakage behavioris formation of a secondary CO2 accumulation at shallow depth. This paperdevelops a detailed numerical simulation model to investigate CO2discharge from a secondary accumulation, and evaluates the role ofdifferent thermodynamic and hydrogeologic conditions. Our simulationsdemonstrate self-enhancing as well as self-limiting feedbacks.Condensation of gaseous CO2, 3-phase flow of aqueous phase -- liquid CO2-- gaseous CO2, and cooling from Joule-Thomson expansion and boiling ofliquid CO2 are found to play important roles in the behavior of a CO2leakage system. We find no evidence that a subsurface accumulation of CO2at ambient temperatures could give rise to a high-energy discharge, aso-called "pneumatic eruption."

  3. Tip-modified Propellers

    DEFF Research Database (Denmark)

    Andersen, Poul

    1999-01-01

    The paper deals with tip-modified propellers and the methods which, over a period of two decades, have been applied to develop such propellers. The development is driven by the urge to increase the efficiency of propellers and can be seen as analogous to fitting end plates and winglets to aircraft...... propeller, have efficiency increases of a reasonable magnitude in both open-water and behind-ship conditions....

  4. Leakage tests of the wall segments of a prestressed concrete containment building

    International Nuclear Information System (INIS)

    Choun, Young Sun; Cho, Nam So

    2005-01-01

    Containment buildings have to maintain their air tightness under extreme loading conditions such as earthquakes, missile impact, and severe accidents to maintain their functional integrity. For evaluating the functional failure of containment buildings, it is important to predict the leakage level through cracked concrete walls. The leakage through concrete cracks has been studied since 1972. Buss examined the flow rate of air through a pre-existing crack in a slab under air pressure. Rizkalla el al. initiated an experimental study for the leakage of prestressed concrete building segments under uniaxial and biaxial loadings to simulate the loading condition of containment buildings under an internal pressure. Recently, Salmon el al. initiated an experimental program for determining the leak rates in typical reinforced concrete shear walls subjected to beyond design basis earthquakes. This study determined the leak rate for the wall segments of a prestressed concrete containment building through leakage tests

  5. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  6. Mechanistic approach to the sodium leakage and fire analysis

    International Nuclear Information System (INIS)

    Yamaguchi, Akira; Muramatsu, Toshiharu; Ohira, Hiroaki; Ida, Masao

    1997-04-01

    In December 1995, a thermocouple well was broken and liquid sodium leaked out of the intermediate heat transport system of the prototype fast breeder reactor Monju. In the initiating process of the incident, liquid sodium flowed out through the hollow thermocouple well, nipple and connector. As a result, liquid sodium, following ignition and combustion, was dropping from the connector to colide with the duct and grating placed below. The collision may cause fragmentation and scattering of the sodium droplet that finally was piled up on the floor. This report deals with the development of computer programs for the phenomena based on mechanistics approach. Numerical analyses are also made for fundamental sodium leakage and combustion phenomenon, sodium combustion experiment, and Monju incident condition. The contents of this report is listed below: (1) Analysis of chemical reaction process based on molecular orbital method, (2) Thermalhy draulic analysis of the sodium combustion experiment II performed in 1996 at O-arai Engineering Center, PNC, (3) Thermalhy draulic analysis of room A-446 of Monju reactor when the sodium leakage took place, (4) Direct numerical simulation of sodium droplet, (5) Sodium leakage and scattering analysis using three dimensional particle method, (6) Multi-dimensional combustion analysis and multi-point approximation combustion analysis code. Subsequent to the development work of the programs, they are to be applied to the safety analysis of the Fast Breeder Reactor. (author)

  7. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  8. Design of Earth Leakage Circuit Breaker on Sensitivity 20 MA

    Directory of Open Access Journals (Sweden)

    Pandung Sarungallo

    2008-08-01

    Full Text Available Electrics current can flow out to the ground by using a human body. This electric current will be dangerous to the human when it exceed 20mA. A very sensitive earth leakage circuit breaker (ELCB is needed to anticipate the leaky current but most of ELCB can only be found in the market with sensitivitas 30mA or bigger. This research is succees to design an ELCB with sensitivity 20mA. Characteristic of an ELCB is very influenced by the current transformer characteristic and the relay which are used.

  9. Simulations of hydraulic fracturing and leakage in sedimentary basins

    Energy Technology Data Exchange (ETDEWEB)

    Lothe, Ane Elisabeth

    2004-01-01

    Hydraulic fracturing and leakage of water through the caprock is described from sedimentary basin over geological time scale. Abnormal pressure accumulations reduce the effective stresses in the underground and trigger the initiation of hydraulic fractures. The major faults in the basin define these pressure compartments. In this Thesis, basin simulations of hydraulic fracturing and leakage have been carried out. A simulator (Pressim) is used to calculate pressure generation and dissipitation between the compartments. The flux between the compartments and not the flow within the compartments is modelled. The Griffith-Coulomb failure criterion determines initial failure at the top structures of overpressured compartments, whereas the frictional sliding criterion is used for reactivation along the same fractures. The minimum horizontal stress is determined from different formulas, and an empirical one seems to give good results compared to measured pressures and minimum horizontal stresses. Simulations have been carried out on two datasets; one covering the Halten Terrace area and one the Tune Field area in the northern North Sea. The timing of hydraulic fracturing and amount of leakage has been quantified in the studies from the Halten Terrace area. This is mainly controlled by the lateral fluid flow and the permeability of the major faults in the basin. Low fault permeability gives early failure, while high fault permeabilities results in no or late hydraulic fracturing and leakage from overpressured parts of the basin. In addition to varying the transmissibility of all faults in a basin, the transmissibility across individual faults can be varied. Increasing the transmissibility across faults is of major importance in overpressured to intermediately pressured areas. However, to obtain change in the flow, a certain pressure difference has to be the situation between the different compartments. The coefficient of internal friction and the coefficient of frictional

  10. Thulium fiber laser lithotripsy using small spherical distal fiber tips

    Science.gov (United States)

    Wilson, Christopher R.; Hardy, Luke A.; Kennedy, Joshua D.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-02-01

    This study tests a 100-μm-core fiber with 300-μm-diameter ball tip during Thulium fiber laser (TFL) lithotripsy. The TFL was operated at 1908 nm wavelength with 35-mJ pulse energy, 500-μs pulse duration, and 300-Hz pulse rate. Calcium oxalate/phosphate stone samples were weighed, laser procedure times measured, and ablation rates calculated for ball tip fibers, with comparison to bare tip fibers. Photographs of ball tips were taken before and after each procedure to observe ball tip degradation and determine number of procedures completed before need to replace fiber. Saline irrigation rates and ureteroscope deflection were measured with and without TFL fiber present. There was no statistical difference (P > 0.05) between stone ablation rates for single-use ball tip fiber (1.3 +/- 0.4 mg/s) (n=10), multiple-use ball tip fiber (1.3 +/- 0.5 mg/s) (n=44), and conventional single-use bare tip fibers (1.3 +/- 0.2 mg/s) (n=10). Ball tip durability varied widely, but fibers averaged > 4 stone procedures before decline in stone ablation rates due to mechanical damage at front surface of ball tip. The small fiber diameter did not impact ureteroscope deflection or saline flow rates. The miniature ball tip fiber may provide a cost-effective design for safe fiber insertion through the ureteroscope working channel and the ureter without risk of scope damage or tissue perforation, and without compromising stone ablation efficiency during TFL ablation of kidney stones.

  11. On the opening of premixed Bunsen flame tips

    Science.gov (United States)

    Law, C. K.; Ishizuka, S.; Cho, P.

    1982-01-01

    The local extinction of Bunsen flame tip and edges of hydrocarbon/air premixtures has been experimentally investigated using a variety of burners. Results show that, while for both rich propane/air and butane/air mixtures tip opening occurs at a constant fuel equivalence ratio of 1.44 and is therefore independent of the intensity, uniformity, and configuration of the approach flow, for rich methane/air flames burning is intensified at the tip and therefore opening is not possible. These results substantiate the concept and dominance of the diffusional stratification mechanism in causing extinction, and clarify the theoretical predictions on the possible opening of two-dimensional flame wedges.

  12. Efficient Reservoir Simulation with Cubic Plus Association and Cross-Association Equation of State for Multicomponent Three-Phase Compressible Flow with Applications in CO2 Storage and Methane Leakage

    Science.gov (United States)

    Moortgat, J.

    2017-12-01

    We present novel simulation tools to model multiphase multicomponent flow and transport in porous media for mixtures that contain non-polar hydrocarbons, self-associating polar water, and cross-associating molecules like methane, ethane, unsaturated hydrocarbons, CO2 and H2S. Such mixtures often occur when CO2 is injected and stored in saline aquifers, or when methane is leaking into groundwater. To accurately predict the species transfer between aqueous, gaseous and oleic phases, and the subsequent change in phase properties, the self- and cross-associating behavior of molecules needs to be taken into account, particularly at the typical temperatures and pressures in deep formations. The Cubic-Plus-Association equation-of-state (EOS) has been demonstrated to be highly accurate for such problems but its excessive computational cost has prevented widespread use in reservoir simulators. We discuss the thermodynamical framework and develop sophisticated numerical algorithms that allow reservoir simulations with efficiencies comparable to a simple cubic EOS. This approach improves our predictive powers for highly nonlinear fluid behavior related to geological carbon sequestration, such as density driven flow and natural convection (solubility trapping), evaporation of water into the CO2-rich gas phase, and competitive dissolution-evaporation when CO2 is injected in, e.g., methane saturated aquifers. Several examples demonstrate the accuracy and robustness of this EOS framework for complex applications.

  13. Tipping point leadership.

    Science.gov (United States)

    Kim, W Chan; Mauborgne, Renée

    2003-04-01

    When William Bratton was appointed police commissioner of New York City in 1994, turf wars over jurisdiction and funding were rife and crime was out of control. Yet in less than two years, and without an increase in his budget, Bratton turned New York into the safest large city in the nation. And the NYPD was only the latest of five law-enforcement agencies Bratton had turned around. In each case, he succeeded in record time despite limited resources, a demotivated staff, opposition from powerful vested interests, and an organization wedded to the status quo. Bratton's turnarounds demonstrate what the authors call tipping point leadership. The theory of tipping points hinges on the insight that in any organization, fundamental changes can occur quickly when the beliefs and energies of a critical mass of people create an epidemic movement toward an idea. Bratton begins by overcoming the cognitive hurdles that block organizations from recognizing the need for change. He does this by putting managers face-to-face with operational problems. Next, he manages around limitations on funds, staff, or equipment by concentrating resources on the areas that are most in need of change and that have the biggest payoffs. He meanwhile solves the motivation problem by singling out key influencers--people with disproportionate power due to their connections or persuasive abilities. Finally, he closes off resistance from powerful opponents. Not every CEO has the personality to be a Bill Bratton, but his successes are due to much more than his personality. He relies on a remarkably consistent method that any manager looking to turn around an organization can use to overcome the forces of inertia and reach the tipping point.

  14. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  15. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  16. Heterogeneity-enhanced gas phase formation in shallow aquifers during leakage of CO2-saturated water from geologic sequestration sites

    DEFF Research Database (Denmark)

    Plampin, Michael R.; Lassen, Rune Nørbæk; Sakaki, Toshihiro

    2014-01-01

    A primary concern for geologic carbon storage is the potential for leakage of stored carbon dioxide (CO2) into the shallow subsurface where it could degrade the quality of groundwater and surface water. In order to predict and mitigate the potentially negative impacts of CO2 leakage, it is import......A primary concern for geologic carbon storage is the potential for leakage of stored carbon dioxide (CO2) into the shallow subsurface where it could degrade the quality of groundwater and surface water. In order to predict and mitigate the potentially negative impacts of CO2 leakage...... concentration in the flowing water, the distance between the heterogeneity and the leakage location, and some fundamental properties of the porous media. Results also show that interfaces where a less permeable material overlies a more permeable material affect gas phase evolution more significantly than...

  17. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  18. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  19. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  20. Trapping of particles by the leakage of a standing wave ultrasonic field

    Science.gov (United States)

    Liu, Yanyan; Hu, Junhui

    2009-08-01

    This paper presents a method of trapping particles by the acoustic leakage from a low frequency standing wave ultrasonic field. The standing wave ultrasonic field is generated in a triangular air gap between two vibrating V-shaped metal strips. Particles are trapped to the lower outlet of the standing wave ultrasonic field. The acoustic radiation force acting on the particles in this method is opposite to the direction of the acoustic leakage. Particles such as medicine pills with a weight up to 256 mg per particle can be trapped. A physical model is developed to analyze the trapping phenomena. The effects of the vibration displacement amplitude at the tip of the V-shaped metal strip, particle's shape and weight, and size of standing wave ultrasonic field on the trapping capability are investigated theoretically and experimentally.

  1. The effect of gap width on viscous stresses within the leakage across a bileaflet valve pivot

    DEFF Research Database (Denmark)

    Travis, Brandon R; Andersen, Morten E; Fründ, Ernst Torben

    2008-01-01

    BACKGROUND AND AIM OF THE STUDY: Stresses of leakage flow may contribute to the increased tendency for thromboembolic complications in patients with mechanical valves. In bileaflet valves, leakage occurs primarily in the pivots, and the width of the pivot gap influences viscous stress magnitudes...... were performed, varying gap width between the leaflet and housing in the pivot region. To validate these calculations, steady leakage across a scaled in-vitro model of a single pivot was initiated, and velocity measurements at specific locations within flow the pivot were obtained using one......-component laser Doppler velocimetry. RESULTS: The average viscous stresses on the housing surface of the pivot increased from 198 to 299 Pa, and on the leaflet surface from 242 to 271 Pa, as gap width was increased from 100 to 300 microm. These stresses were similar in magnitude to the maximum turbulent stresses...

  2. AERODYNAMICS OF WING TIP SAILS

    Directory of Open Access Journals (Sweden)

    MUSHTAK AL-ATABI

    2006-06-01

    Full Text Available Observers have always been fascinated by soaring birds. An interesting feature of these birds is the existence of few feathers extending from the tip of the wing. In this paper, small lifting surfaces were fitted to the tip of a NACA0012 wing in a fashion similar to that of wing tip feathers. Experimental measurements of induced drag, longitudinal static stability and trailing vortex structure were obtained.The tests showed that adding wing tip surfaces (sails decreased the induced drag factor and increased the longitudinal static stability. Results identified two discrete appositely rotated tip vortices and showed the ability of wing tip surfaces to break them down and to diffuse them.

  3. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    : This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy...... interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6...... instead of clinical leakage. However, anastomotic breaking strength was reduced in the ischemic anastomoses. STUDY 4: In this systematic review MEDLINE, Embase and Cinahl were searched up to September 2011 to identify studies evaluating external coating of colonic anastomoses. Most studies were...

  4. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...... to be used in commercial PV inverters for the measurement of leakage and fault ground currents. The German VDE0126–1–1 standard gives the limit for fault and leakage ground currents and all grid connected PV inverters have to comply with these limits and disconnect from the grid in case of a fault....

  5. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States); Shaffer, M. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Wärme und Feuchte instationär Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  6. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D.; Shaffer, M.

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Warme und Feuchte instationar Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  7. Studies of water leakage in dams. Course

    International Nuclear Information System (INIS)

    Cordero-Calderon, C.F.

    1995-01-01

    With this training about the study of Water Leakage in Dams and Damming, the institutional worker will have the necessary criteria in this topic, and also an opportunity to analyze the impact of this engineering work at national level. This course permits to transmit part of the knowlege acquired by the Arcal XVIII RLA/8/018, Application of Tracer Techniques for Leakage in Dams and Damming Project, where ICE participates in agreement with Atomic Energy Commission of Costa Rica, sponsored by the International Organization of Atomic Energy. (author). 14 charts, 36 figs, 2 maps, 6 tabs

  8. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario

    Directory of Open Access Journals (Sweden)

    Jing Ma

    2017-11-01

    Full Text Available The technology of carbon dioxide (CO2 capture and storage (CCS has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO2 geological storage was designed to investigate the short-term effects of different CO2 leakage concentration (from 400 g m−2 day−1 to 2,000 g m−2 day−1 on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO2 concentrations. Increasing CO2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 (p < 0.05. Nitrate nitrogen content varied from 1.01 to 4.03 mg/Kg, while Olsen-phosphorus and total phosphorus demonstrated less regular downtrends. The fluorescein diacetate (FDA hydrolytic enzyme activity was inhibited by the increasing CO2 flux, with the average content varying from 22.69 to 11.25 mg/(Kg h (p < 0.05. However, the increasing activity amplitude of the polyphenol oxidase enzyme approached 230%, while the urease activity presented a similar rising trend. Alpha diversity results showed that the Shannon index decreased from 7.66 ± 0.13 to 5.23 ± 0.35 as the soil CO2 concentration increased. The dominant phylum in the soil samples was Proteobacteria, whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% (p < 0.01. Moreover, the abundances of genera Methylophilus, Methylobacillus, and Methylovorus increased, while GP4, GP6 and GP7 decreased. Canonical correlation analysis

  9. The effect of gap width on viscous stresses within the leakage across a bileaflet valve pivot

    DEFF Research Database (Denmark)

    Travis, Brandon R; Andersen, Morten E; Fründ, Ernst Torben

    2008-01-01

    reported within the pivots in previous studies. Velocities measured experimentally were even larger than those estimated computationally. CONCLUSION: These experiments suggest that viscous stresses in leakage flow across a bileaflet mitral valve increase with gap width, and may contribute more to blood...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS): Current Status and Future Possibilities

    International Nuclear Information System (INIS)

    Bilbao, Jose Ignacio; Quiroga, Jorge; Herrero, Jose Ignacio; Benito, Alberto

    2002-01-01

    Since the insertion of the first TIPS in 1989 much has been learned about this therapeutic procedure. It has an established role for the treatment of some complications of portal hypertension: prevention of recurrent variceal bleeding and rescue of patients with acute uncontrollable variceal bleeding. In addition TIPS is useful for Budd-Chiari syndrome, refractory ascites and hepatorenal syndrome, although its specific role in these indications remains to be definitively established. However, the decrease in sinusoidal blood flow induced by TIPS can lead to the patient developing hepatic encephalopathy and liver failure in some cases. Therefore, TIPS should be used with caution in patients with very poor liver function. From a technical point of view, successful placement of TIPS is achieved in more than 98% of cases by experienced groups. At present, evaluation of TIPS dysfunction based on morphology probably leads to an overdiagnosis of this complication since most of these cases are not associated with clinical manifestations (recurrent bleeding or refractory ascites). The major disadvantage of TIPS remains its poor long-term patency requiring a mandatory surveillance program. The indicator for shunt function/malfunction should be the portosystemic pressure gradient, which is best assessed by intravascular measurements. Shunt obstructions may be prevented or reduced by the use of stent-grafts in the future

  11. Analytical methods of leakage rate estimation from a containment under a LOCA

    International Nuclear Information System (INIS)

    Chun, M.H.

    1981-01-01

    Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from then mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than the mass leakage rate formula of CONTEMPT-LT. (author)

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... liver disease are at greater risk for worsening liver failure after TIPS. If your liver failure is severe, a TIPS may not be the ... children are more likely to be performed before liver transplant in those with ascites or variceal ... 08, 2017 Send us your feedback Did you find the ...

  13. Dynamic Characteristics of Rotating Stall in Mixed Flow Pump

    Directory of Open Access Journals (Sweden)

    Xiaojun Li

    2013-01-01

    Full Text Available Rotating stall, a phenomenon that causes flow instabilities and pressure hysteresis by propagating at some fraction of the impeller rotational speed, can occur in centrifugal impellers, mixed impellers, radial diffusers, or axial diffusers. Despite considerable efforts devoted to the study of rotating stall in pumps, the mechanics of this phenomenon are not sufficiently understood. The propagation mechanism and onset of rotating stall are not only affected by inlet flow but also by outlet flow as well as the pressure gradient in the flow passage. As such, the complexity of these concepts is not covered by the classical explanation. To bridge this research gap, the current study investigated prerotation generated at the upstream of the impeller, leakage flow at the tip clearance between the casing and the impeller, and strong reserve flow at the inlet of the diffuser. Understanding these areas will clarify the origin of the positive slope of the head-flow performance curve for a mixed flow pump. Nonuniform pressure distribution and adverse pressure gradient were also introduced to evaluate the onset and development of rotating stall within the diffuser.

  14. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attacker...... on the Onion Routing protocol....

  15. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  16. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  17. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  18. Pre-Liver Transplant: Tips Versus Distal Splenorenal Shunt

    Directory of Open Access Journals (Sweden)

    Thomas W. Faust

    1997-01-01

    Full Text Available Recurrent variceal bleeding in liver transplant candidates with end-stage liver disease can complicate or even prohibit a subsequent transplant procedure (OLT. Endoscopic sclero-therapy and medical therapy are considered as first-line management with surgical shunts reserved for refractory situations. Surgical shunts can be associated with a high mortality in this population and may complicate subsequent OLT. The transjugular intrahepatic portosystemic shunt (TIPS has been recommended in these patients as a bridge to OLT. This is a new modality that has not been compared with previously established therapies such as the distal splenorenal shunt (DSRS. In this study we report our experience with 35 liver transplant recipients who had a previous TIPS (18 patients or DSRS (17 patients for variceal bleeding. The TIPS group had a significantly larger proportion of critically ill and Child-Pugh C patients. Mean operating time was more prolonged in the DSRS group (P=0.014 but transfusion requirements were similar. Intraoperative portal vein blood flow measurements averaged 2132±725 ml/min in the TIPS group compared with 1120±351ml/min in the DSRS group (P<0.001. Arterial flows were similar. Mean ICU and hospital stays were similar. There were 3 hospital mortalities in the DSRS group and none in the TIPS group (P=0.1. We conclude that TIPS is a valuable tool in the management of recurrent variceal bleeding prior to liver transplantation. Intra0Perative hemodynamic measurements suggest a theoretical advantage with TIPS. In a group of patients with advanced liver disease we report an outcome that is similar to patients treated with DSRS prior to liver transplantation. The role of TIPS in the treatment of nontransplant candidates remains to be clarified.

  19. Flow

    DEFF Research Database (Denmark)

    Knoop, Hans Henrik

    2006-01-01

    FLOW. Orden i hovedet på den fede måde Oplevelsesmæssigt er flow-tilstanden kendetegnet ved at man er fuldstændig involveret, fokuseret og koncentreret; at man oplever stor indre klarhed ved at vide hvad der skal gøres, og i hvilket omfang det lykkes; at man ved at det er muligt at løse opgaven...

  20. Numerical analysis of gas leakage in the piston-cylinder clearance of reciprocating compressors considering compressibility effects

    Science.gov (United States)

    Braga, V. M.; Deschamps, C. J.

    2017-08-01

    Leakage is a major source of inefficiency in low-capacity reciprocating compressors. Not only does it lower the mass flow rate provided by the compressor, reducing its volumetric efficiency, but also gives rise to outflux of energy that decreases the isentropic efficiency. Leakage in the piston-cylinder clearance of reciprocating compressors is driven by the piston motion and pressure difference between the compression chamber and the shell internal environment. In compressors adopted for domestic refrigeration, such a clearance is usually filled by a mixture of refrigerant and lubricating oil. Besides its lubricating function, the oil also acts as sealing element for the piston-cylinder clearance, and hence leakage is expected to be more detrimental to oil-free compressors. This paper presents a model based on the Reynolds equation for compressible fluid flow to predict leakage in oil-free reciprocating compressors. The model is solved throughout the compression cycle so as to assess the effect of the clearance geometry and piston velocity on leakage and compressor efficiency. The results show that compressible fluid flow formulation must be considered for predictions of gas leakage in the cylinder-piston clearance.

  1. Leakage monitoring. Acoustic leakage monitoring by means of neural networks in complex pressurized plants

    International Nuclear Information System (INIS)

    Hessel, G.; Schmitt, W.; Vorst, K. van der; Weiss, F.P.

    1996-01-01

    A leakage detection and leakage rate assessment method developed for pressurized plants characterized by a complex three-dimensional topology is introduced. It is based on the features of leak-induced structure-borne or air-borne noise and uses neural networks for pattern recognition. The sound patterns required for neural network instruction can be generated by simulating leaks in the original structure. The method described can also be applied when leakage detection based on skews or damping differences fails. A prototype was developed and tested for a WWER-type reactor. Coherence values of highfrequency microphone signals or the effective values of sound emission sensor signals were used as features for characterization of the leak. The leakage rate assessment features were derived from these effective values. Neural networks allow one to easily adapt the method to pressurized plants of different topologies. (orig.) [de

  2. Numerical Prediction of Tip Vortex Cavitation for Marine Propellers in Non-uniform Wake

    Science.gov (United States)

    Zhu, Zhi-Feng; Zhou, Fang; Li, Dan

    2017-07-01

    Tip vortex cavitation is the first type of cavitation to take place around most marine propellers. But the numerical prediction of tip vortex cavitation is one of the challenges for propeller wake because of turbulence dissipation during the numerical simulation. Several parameters of computational mesh and numerical algorithm are tested by mean of the predicted length of tip vortex cavtiation to validate a developed method. The predicted length of tip vortex cavtiation is on the increase about 0.4 propeller diameters using the developed numerical method. The predicted length of tip vortex cavtiation by RNG k - ɛ model is about 3 times of that by SST k - ω model. Therefore, based on the validation of the present approach, the cavitating flows generated by two rotating propellers under a non-uniform inflow are calculated further. The distributions of axial velocity, total pressure and vapor volume fraction in the transversal planes across tip vortex region are shown to be useful in analyzing the feature of the cavitating flow. The strongest kernel of tip vortex cavitation is not at the position most close to blade tip but slightly far away from the region. During the growth of tip vortex cavitation extension, it appears short and thick, and then it becomes long and thin. The pressure fluctuations at the positions inside tip vortex region also validates the conclusion. A key finding of the study is that the grids constructed especially for tip vortex flows by using separated computational domain is capable of decreasing the turbulence dissipation and correctly capturing the feature of propeller tip vortex cavitation under uniform and non-uniform inflows. The turbulence model and advanced grids is important to predict tip vortex cavitation.

  3. Tipping the scales.

    Science.gov (United States)

    1998-12-01

    In the US, the October 1998 murder of a physician who performed abortions was an outward manifestation of the insidious battle against legal abortion being waged by radical Christian social conservatives seeking to transform the US democracy into a theocracy. This movement has been documented in a publication entitled, "Tipping the Scales: The Christian Right's Legal Crusade Against Choice" produced as a result of a 4-year investigation conducted by The Center for Reproductive Law and Policy. This publication describes how these fundamentalists have used sophisticated legal, lobbying, and communication strategies to further their goals of challenging the separation of church and state, opposing family planning and sexuality education that is not based solely on abstinence, promoting school prayer, and restricting homosexual rights. The movement has resulted in the introduction of more than 300 anti-abortion bills in states, 50 of which have passed in 23 states. Most Christian fundamentalist groups provide free legal representation to abortion clinic terrorists, and some groups solicit women to bring specious malpractice claims against providers. Sophisticated legal tactics are used by these groups to remove the taint of extremism and mask the danger posed to US constitutional principles being posed by "a well-financed and zealous brand of radical lawyers and their supporters."

  4. Torsional Phacoemulsification and Tip Selection

    Directory of Open Access Journals (Sweden)

    Fırat Helvacıoğlu

    2014-10-01

    Full Text Available One of the recent advances in cataract surgery is torsional phacoemulsification. It was developed to increase the efficacy of ultrasonic emulsification. In torsional phacoemulsification, the torsional movement of the tip is translated to side-to-side cutting action with the aid of bent phaco tips. Lens material is cut in both directions, rather than only during a forward stroke. The efficiency of this technique is further enhanced by an improvement in followability provided by the inherent non-repulsive nature of the side-to-side motion. Tip selection is very important for the efficiency of torsional phacoemulsification. Theoretically, there are 2 ways to enhance the cutting efficiency of the tip. First is the stroke length; the 22-degree bent 30-degree Kelman mini-flared tip cuts longer than the 12-degree bent 30-degree mini-flared Kelman tip. Second is the angulation or bevel; the higher the degree (45 degrees, the better cutting efficiency. Retrospective analyses of the previously published clinical studies clearly demonstrated that the efficacy of the torsional phacoemulsification has positive correlation with both the aperture angles and neck angles of the tips. (Turk J Ophthalmol 2014; 44: 392-5

  5. Numerical Modeling of Methane Leakage from a Faulty Natural Gas Well into Fractured Tight Formations.

    Science.gov (United States)

    Moortgat, Joachim; Schwartz, Franklin W; Darrah, Thomas H

    2018-03-01

    Horizontal drilling and hydraulic fracturing have enabled hydrocarbon recovery from unconventional reservoirs, but led to natural gas contamination of shallow groundwaters. We describe and apply numerical models of gas-phase migration associated with leaking natural gas wells. Three leakage scenarios are simulated: (1) high-pressure natural gas pulse released into a fractured aquifer; (2) continuous slow leakage into a tilted fractured formation; and (3) continuous slow leakage into an unfractured aquifer with fluvial channels, to facilitate a generalized evaluation of natural gas transport from faulty natural gas wells. High-pressure pulses of gas leakage into sparsely fractured media are needed to produce the extensive and rapid lateral spreading of free gas previously observed in field studies. Transport in fractures explains how methane can travel vastly different distances and directions laterally away from a leaking well, which leads to variable levels of methane contamination in nearby groundwater wells. Lower rates of methane leakage (≤1 Mcf/day) produce shorter length scales of gas transport than determined by the high-pressure scenario or field studies, unless aquifers have low vertical permeabilities (≤1 millidarcy) and fractures and bedding planes have sufficient tilt (∼10°) to allow a lateral buoyancy component. Similarly, in fractured rock aquifers or where permeability is controlled by channelized fluvial deposits, lateral flow is not sufficiently developed to explain fast-developing gas contamination (0-3 months) or large length scales (∼1 km) documented in field studies. Thus, current efforts to evaluate the frequency, mechanism, and impacts of natural gas leakage from faulty natural gas wells likely underestimate contributions from small-volume, low-pressure leakage events. © 2018, National Ground Water Association.

  6. RETRAN code analysis of Tsuruga-2 plant chemical volume control system (CVCS) reactor coolant leakage incident

    International Nuclear Information System (INIS)

    Kawai, H.

    2001-01-01

    JAPC purchased RETRAN, a program for transient thermal hydraulic analysis of complex fluid flow system, from the U.S. Electric Power Research Institute in 1992. Since then, JAPC has been utilizing RETRAN to evaluate safety margins of actual plant operation, in coping with troubles (investigating trouble causes and establishing countermeasures), and supporting reactor operation (reviewing operational procedures etc.). In this paper, a result of plant analysis performed on a CVCS reactor primary coolant leakage incident which occurred at JAPC's Tsuruga-2 plant (4-loop PWR, 3423 MWt, 1160 MW) on July 12 of 1999 and, based on the result, we made a plan to modify our operational procedure for reactor primary coolant leakage events in order to make earlier plant shutdown and this reduced primary coolant leakage. (author)

  7. Carbon Leakage, Free Allocation and Linking Emissions Trading Schemes

    NARCIS (Netherlands)

    Tiche, Fitsum G.; Weishaar, Stefan E.; Couwenberg, Oscar

    2014-01-01

    A sub-global emissions trading scheme (ETS) risks harming competitiveness and causing carbon leakage. These concerns cast doubt on the efficiency and environmental effectiveness of unilateral climate policies. ETSs implemented thus far include measures to address competitiveness and leakage

  8. Active control of the tip vortex: an experimental investigation on the performance characteristics of a model turbine

    International Nuclear Information System (INIS)

    Anik, E; Abdulrahim, A; Ostovan, Y; Mercan, B; Uzol, O

    2014-01-01

    This study is part of an on-going experimental research campaign that focuses on the active control of the tip leakage/vortex characteristics of a model horizontal axis wind turbine rotor using tip injection. This paper presents both baseline (no-injection) data as well as data with tip injection, concentrating on the effects of tip injection on power and thrust variations with the Tip Speed Ratio (TSR). The experiments are conducted by placing a specially designed 3-bladed model wind turbine rotor at the exit of a 1.7 m diameter open-jet wind tunnel. The rotor blades are non-linearly twisted and tapered with NREL S826 airfoil profile all along the span. The nacelle, hub and the blades are specifically designed to allow pressurized air to pass through and get injected from the blade tips while the rotor is rotating. Baseline results show that the general trends are as expected for a small wind turbine and the maximum power coefficient is reached at around TSR=4.5. Results with injection show that the tip injection has significant effect on the power and thrust coefficients in comparison to the baseline data, especially at TSR values higher than the max C P TSR value. Both coefficients seem to be significantly increased due to tip injection and the max C P TSR value also gets shifted to a slightly higher TSR value. Tip injection seems to have no significant effect for TSR values less than 3.5

  9. A catchment-scale groundwater model including sewer pipe leakage in an urban system

    Science.gov (United States)

    Peche, Aaron; Fuchs, Lothar; Spönemann, Peter; Graf, Thomas; Neuweiler, Insa

    2016-04-01

    Keywords: pipe leakage, urban hydrogeology, catchment scale, OpenGeoSys, HYSTEM-EXTRAN Wastewater leakage from subsurface sewer pipe defects leads to contamination of the surrounding soil and groundwater (Ellis, 2002; Wolf et al., 2004). Leakage rates at pipe defects have to be known in order to quantify contaminant input. Due to inaccessibility of subsurface pipe defects, direct (in-situ) measurements of leakage rates are tedious and associated with a high degree of uncertainty (Wolf, 2006). Proposed catchment-scale models simplify leakage rates by neglecting unsaturated zone flow or by reducing spatial dimensions (Karpf & Krebs, 2013, Boukhemacha et al., 2015). In the present study, we present a physically based 3-dimensional numerical model incorporating flow in the pipe network, in the saturated zone and in the unsaturated zone to quantify leakage rates on the catchment scale. The model consists of the pipe network flow model HYSTEM-EXTAN (itwh, 2002), which is coupled to the subsurface flow model OpenGeoSys (Kolditz et al., 2012). We also present the newly developed coupling scheme between the two flow models. Leakage functions specific to a pipe defect are derived from simulations of pipe leakage using spatially refined grids around pipe defects. In order to minimize computational effort, these leakage functions are built into the presented numerical model using unrefined grids around pipe defects. The resulting coupled model is capable of efficiently simulating spatially distributed pipe leakage coupled with subsurficial water flow in a 3-dimensional environment. References: Boukhemacha, M. A., Gogu, C. R., Serpescu, I., Gaitanaru, D., & Bica, I. (2015). A hydrogeological conceptual approach to study urban groundwater flow in Bucharest city, Romania. Hydrogeology Journal, 23(3), 437-450. doi:10.1007/s10040-014-1220-3. Ellis, J. B., & Revitt, D. M. (2002). Sewer losses and interactions with groundwater quality. Water Science and Technology, 45(3), 195

  10. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in the chest or abdomen. This condition is most commonly seen in adults, often as a result ... minimally invasive procedures such as a TIPS are most often performed by a specially trained interventional radiologist ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and lengthy procedures requiring extended fluoroscopy use) death (rare) top of page What are the limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening liver failure ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... less likely to require a TIPS. top of page What are some common uses of the procedure? A ... gown to wear during the procedure. top of page What does the equipment look like? In this procedure, ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the hepatic vein in the liver. A small metal device called a stent is placed to keep ... open by the placement of a small, tubular metal device commonly called a stent . During a TIPS ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... of bleeding that can occur can sometimes be life threatening and those patients are monitored in intensive ... invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of ...

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients ... site. Using ultrasound, the doctor will identify your internal jugular vein , which is situated above your collarbone, ...

  19. Choking and Strangulation Prevention Tips

    Science.gov (United States)

    ... Safety Sponsors Recalls Media Center Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Search Menu Why It Matters ... Safety Sponsors Recalls Media Center Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Sign up for quick tips ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... hepatic vein to identify the portal venous system. Access is then gained from the hepatic vein into ... TIPS procedure to make sure that it remains open and functions properly. top of page Who interprets ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ... American College of Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise ...

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the portal system using a TIPS needle (a special long needle extending from the neck into the ... Encephalopathy can be treated with certain medications, a special diet or, by revising the stent, but sometimes ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients with cirrhosis. Tell your ... the liver into the veins of the spleen, stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in an hour or two but may take up to several hours depending on the complexity of ... normal activities in seven to 10 days. Follow-up ultrasounds will be performed frequently after the TIPS ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... portal vein to the hepatic vein in the liver. A small metal device called a stent is ... bowel back to the heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... of an effect than open surgical bypass on future liver transplantation surgery because the abdomen has not ... TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... blood draining from the bowel back to the heart while avoiding the liver. TIPS may successfully reduce ... blood away from the liver back to the heart). A stent is then placed in this tunnel ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. You ... with ascites or variceal bleeding resistant to traditional medical treatments. The greatest difference in performing TIPS in ...

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  10. Search Tips: MedlinePlus

    Science.gov (United States)

    ... of this page: https://medlineplus.gov/searchtips.html Search Tips To use the sharing features on this page, please enable JavaScript. How do I search MedlinePlus? The search box appears at the top ...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... to the heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and ... conditions, allergies and medications you’re taking. You may be advised to stop taking aspirin, nonsteroidal anti- ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... risks. Other possible complications of the procedure include: fever muscle stiffness in the neck bruising on the ... filtered out by the liver. The TIPS may cause too much of these substances to bypass the ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients with ... stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding and the accumulation of fluid in the chest ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... liver back to the heart. top of page How should I prepare? You should report to your ... heart beat and blood pressure. top of page How does the procedure work? A TIPS reroutes blood ...

  15. Computerized automatic tip scanning operation

    International Nuclear Information System (INIS)

    Nishikawa, K.; Fukushima, T.; Nakai, H.; Yanagisawa, A.

    1984-01-01

    In BWR nuclear power stations the Traversing Incore Probe (TIP) system is one of the most important components in reactor monitoring and control. In previous TIP systems, however, operators have suffered from the complexity of operation and long operation time required. The system presented in this paper realizes the automatic operation of the TIP system by monitoring and driving it with a process computer. This system significantly reduces the burden on customer operators and improves plant efficiency by simplifying the operating procedure, augmenting the accuracy of the measured data, and shortening operating time. The process computer is one of the PODIA (Plant Operation by Displayed Information Automation) systems. This computer transfers control signals to the TIP control panel, which in turn drives equipment by microprocessor control. The process computer contains such components as the CRT/KB unit, the printer plotter, the hard copier, and the message typers required for efficient man-machine communications. Its operation and interface properties are described

  16. Tips to Prevent Tick Bites

    Science.gov (United States)

    Using the right insect repellent and other preventive actions can discourage ticks, mosquitoes, and other biting insects from landing on you. Tips include avoiding tick habitats and minimizing exposed skin.

  17. Tips to Prevent Mosquito Bites

    Science.gov (United States)

    Using the right insect repellent and other preventive actions can discourage mosquitoes from landing on you. Tips include removing mosquito habitats such as standing water, minimizing exposed skin, and staying indoors while mosquitoes are most active.

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Patients who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal ... leading to cirrhosis (scarring of the liver). Portal hypertension can also occur in children, although children are ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... deeply you are sedated. When the needle is advanced through the liver and the pathway is expanded ... are the limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A TIPS is used to treat the ... during the procedure. top of page What does the equipment look like? In this procedure, x-ray ...

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... is completed. top of page What are the benefits vs. risks? Benefits A TIPS is designed to produce the same ... urgent intervention heart arrhythmias or congestive heart failure radiation injury to the skin is a rare complication ( ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... local anesthetic medications, general anesthesia or to contrast materials containing iodine (sometimes referred to as "dye" or " ... the placement of the TIPS stent, a contrast material will be injected in the hepatic vein to ...

  4. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  5. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  6. Leakage detection system for radioactive waste storage tanks

    International Nuclear Information System (INIS)

    Woods, W.W.; Eul, W.A.

    1979-01-01

    The patent describes a combination of elements for detecting leakage of electrically conductive fluids from tanks, including a reference electrode, an AC generator connected between the tank and the reference electrode, and one or more sensing electrodes positioned between the tank and the reference electrode. The storage tank and reference electrode are in contact with the ground. When the AC generator is energized, current flows in the circuit, and creates an electric field in the ground between the tank and the reference electrode. The sensing electrodes are positioned so that they are within the electric field when the AC generator is energized. An electric potential measuring device, such as a voltmeter, is used to measure the electric potential at the sensing electrodes relative to the tank. A significant change in the electric potential at any one or more of the sensing electrodes is an indication that a leak has occurred in the tank

  7. Tip model of cold fission

    International Nuclear Information System (INIS)

    Goennenwein, F.; Boersig, B.

    1991-01-01

    Cold fission is defined to be the limiting case of nuclear fission where virtually all of the available energy is converted into the total kinetic energy of the fragments. The fragments have, therefore, to be born in or at least close to their respective ground states. Starting from the viewpoint that cold fission corresponds to most compact scission configurations, energy constraints have been exploited to calculate minimum tip distances between the two nascent fragments in binary fission. Crucial input parameters to this tip model of cold fission are the ground-state deformations of fragment nuclei. It is shown that the minimum tip distances being compatible with energy conservation vary strongly with both the mass and charge fragmentation of the fission prone nucleus. The tip distances refer to nuclei with equivalent sharp surfaces. In keeping with the size of the surface width of leptodermous nuclei, only configurations where the tip distances are smaller than a few fm may be considered as valid scission configurations. From a comparison with experimental data on cold fission this critical tip distance appears to be 3.0 fm for the model parameters chosen. Whenever the model calculation yields tip distances being smaller than the critical value, a necessary condition for attaining cold fission is considered to be fulfilled. It is shown that this criterion allows to understand in fair agreement with experiment which mass fragmentations are susceptible to lead to cold fission and which fragment-charge divisions are the most favored in each isobaric mass chain. Being based merely on energy arguments, the model cannot aim at predicting fragment yields in cold fission. However, the tip model proposed appears well suited to delineate the phase space where cold fission phenomena may come into sight. (orig.)

  8. Energy dissipation in the blade tip region of an axial fan

    Science.gov (United States)

    Bizjan, B.; Milavec, M.; Širok, B.; Trenc, F.; Hočevar, M.

    2016-11-01

    A study of velocity and pressure fluctuations in the tip clearance flow of an axial fan is presented in this paper. Two different rotor blade tip designs were investigated: the standard one with straight blade tips and the modified one with swept-back tip winglets. Comparison of integral sound parameters indicates a significant noise level reduction for the modified blade tip design. To study the underlying mechanisms of the energy conversion and noise generation, a novel experimental method based on simultaneous measurements of local flow velocity and pressure has also been developed and is presented here. The method is based on the phase space analysis by the use of attractors, which enable more accurate identification and determination of the local flow structures and turbulent flow properties. Specific gap flow energy derived from the pressure and velocity time series was introduced as an additional attractor parameter to assess the flow energy distribution and dissipation within the phase space, and thus determines characteristic sources of the fan acoustic emission. The attractors reveal a more efficient conversion of the pressure to kinetic flow energy in the case of the modified (tip winglet) fan blade design, and also a reduction in emitted noise levels. The findings of the attractor analysis are in a good agreement with integral fan characteristics (efficiency and noise level), while offering a much more accurate and detailed representation of gap flow phenomena.

  9. Self-assembled core-polyethylene glycol-lipid shell nanoparticles demonstrate high stability in shear flow.

    Science.gov (United States)

    Shen, Zhiqiang; Ye, Huilin; Kröger, Martin; Li, Ying

    2017-05-24

    A core-polyethylene glycol-lipid shell (CPLS) nanoparticle consists of an inorganic core coated with polyethylene glycol (PEG) polymers, surrounded by a lipid bilayer shell. It can be self-assembled from a PEGylated core with surface-tethered PEG chains, where all the distal ends are covalently bonded to lipid molecules. Upon adding free lipids, a complete lipid bilayer shell can be formed on the surface driven by the hydrophobic nature of lipid tails, leading to the formation of a CPLS nanoparticle. The stability of CPLS nanoparticles in shear flow has been systematically studied through large scale dissipative particle dynamics simulations. CPLS nanoparticles demonstrate higher stability and less deformation in shear flow, compared with lipid vesicles. Burst leakage of drug molecules inside lipid vesicles and CPLS NPs can be induced by the large pores at their tips. These pores are initiated by the maximum stress in the waist region. It further grows along with the tank-treading motion of vesicles or CPLS NPs in shear flow. However, due to the constraints applied by PEG polymers, CPLS NPs are less deformed than vesicles with comparable size under the same flow conditions. Thus, the less deformed CPLS NPs express a smaller maximum stress at waists, demonstrating higher stability. Pore formation at waists, evolving into large pores on vesicles, leads to the burst leakage of drug molecules and complete rupture of vesicles. In contrast, although similar drug leakage in CPLS nanoparticles can occur at high shear rates, pores initiated at moderate shear rates tend to be short-lived and close due to the constraints mediated by PEG polymers. This kind of 'self-healing' capability can be observed over a wide range of shear rates for CPLS nanoparticles. Our results suggest self-assembled CPLS nanoparticles to exhibit high stability during blood circulation without rapid drug leakage. These features make CPLS nanoparticles candidates for a promising drug delivery platform.

  10. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  11. Alopecia associated with unexpected leakage from electron cone

    International Nuclear Information System (INIS)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-01-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region

  12. Filopodial retraction force is generated by cortical actin dynamics and controlled by reversible tethering at the tip

    DEFF Research Database (Denmark)

    Bornschlögl, Thomas; Romero, Stéphane; Vestergaard, Christian L.

    2013-01-01

    at the tip and the retrograde flow at the base of the filopodium. Adhesion of a bead to the filopodial tip locally reduces actin polymerization and leads to retraction via retrograde flow, reminiscent of a process used by pathogens to invade cells. Using optical tweezers, we show that filopodial retraction...

  13. Experimental Study of the Effects of Blade Treatments on the Tip Vortex Characteristics.

    Science.gov (United States)

    Klimchenko, Vera

    2015-11-01

    The current study investigates the effects of blade tip treatments on the characteristics of a wind turbine blade tip vortex. Three blade tip shapes including a blunt edge, leading edge comb, and a winglet were designed and tested in a low speed wind tunnel. The rotor with a blunt edge was considered to be a baseline case corresponding to an untreated blade tip. The leading-edge comb rotor was designed with leading edge tubercles extending from the tip of the blade inward, 6 percent of rotor diameter. The winglet located at the tip of the winglet rotor had a cant angle of 45 degrees. The wind turbine operated at a tip speed ratio of 5 and a tip Reynolds number of 14,000. The tip treatments were intended to weaken the tip vortices by encouraging dissipation (leading edge comb) or promoting the formation of weaker vortices (winglet). Time-resolved and phase-averaged PIV was used to measure the velocity field behind the rotor. The time-averaged velocity field was subtracted from the phase-averaged velocity field to isolate the time-varying components of the flow. The vorticity of the phase-averaged time-varying field was calculated, and the tip vortices were identified using a vortex identification method. Vortex characteristics such as core radius and vortex strength were calculated and compared for the three rotors. The analysis of the vorticity showed that the winglet rotor had weaker tip vortices with a larger core radius, while the serrated tip rotor had strong tip vortices with the same core radius as the baseline case.

  14. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  15. Primary containment intergrated leakage rate testing

    International Nuclear Information System (INIS)

    1977-04-01

    Primary containment integrated leakage rate tests (ILRTs) have previously been conducted with a minimum duration of 24 hr. However, analysis of data from recent ILRTs has shown that a test duration considerably less than 24 hr would have been sufficient. This report summarizes these recent ILRTs and analyzes and discusses the test results. Test and analytical methods, including the LEAKFIT computer program, are also discussed. The conclusion is reached that an ILRT with a duration of 6 hr and at least 20 data points is sufficient

  16. Lyman Continuum Leakage in the Local Universe

    Science.gov (United States)

    Leitherer, Claus; Hernandez, Svea; Lee, Janice; Oey, Sally

    2015-08-01

    Star-forming galaxies are viable candidates for providing the ionizing photon supply accounting for the reionization of the early universe. However, direct determination of the fraction of ionizing photons that can escape the optically thick galaxy ISM is challenging. I will discuss Lyman continuum observations of a sample of massive young star clusters in local galaxies which take advantage of a new capability of HST's Cosmic Origins Spectrograph. The derived photon leakages are compared to values found at high redshift and discussed in the context of cosmological models.

  17. EVA Suit Microbial Leakage Investigation Project

    Science.gov (United States)

    Falker, Jay; Baker, Christopher; Clayton, Ronald; Rucker, Michelle

    2016-01-01

    The objective of this project is to collect microbial samples from various EVA suits to determine how much microbial contamination is typically released during simulated planetary exploration activities. Data will be released to the planetary protection and science communities, and advanced EVA system designers. In the best case scenario, we will discover that very little microbial contamination leaks from our current or prototype suit designs, in the worst case scenario, we will identify leak paths, learn more about what affects leakage--and we'll have a new, flight-certified swab tool for our EVA toolbox.

  18. Nanobits: customizable scanning probe tips

    DEFF Research Database (Denmark)

    Kumar, Rajendra; Shaik, Hassan Uddin; Sardan Sukas, Özlem

    2009-01-01

    We present here a proof-of-principle study of scanning probe tips defined by planar nanolithography and integrated with AFM probes using nanomanipulation. The so-called 'nanobits' are 2-4 mu m long and 120-150 nm thin flakes of Si3N4 or SiO2, fabricated by electron beam lithography and standard...... or dislocation of the tips of the nanobit after several scans. This approach allows an unprecedented freedom in adapting the shape and size of scanning probe tips to the surface topology or to the specific application....... silicon processing. Using a microgripper they were detached from an array and fixed to a standard pyramidal AFM probe or alternatively inserted into a tipless cantilever equipped with a narrow slit. The nanobit-enhanced probes were used for imaging of deep trenches, without visible deformation, wear...

  19. Fluid leakage through fractures in an impervious caprock embedded between two geologic aquifers

    Science.gov (United States)

    Selvadurai, A. P. S.

    2012-06-01

    The paper develops an analytical result for the flow through a single fracture under a hydraulic gradient between the two aquifer regions and takes into account permeability characteristics of all components of the system. Non-dimensional results are presented to illustrate the influence of the permeability mis-match between the two geologic formations and the permeability and geometry of the fracture on the flow rate through the fracture. The analytical result is then used to develop additional results for leakage through a swarm of vertically aligned hydraulically non-interacting fractures and a damaged region containing a densely spaced array of vertically aligned fractures and worm hole type features in the caprock. The work presents a convenient result for the estimation of leakage from storage formations in geoenvironmental applications.

  20. Stability of helical tip vortices in a rotor far wake

    DEFF Research Database (Denmark)

    Okulov, Valery; Sørensen, Jens Nørkær

    2007-01-01

    , corresponding to Rankine, Gaussian and Scully vortices, at radial extents ranging from the core radius of a tip vortex to several rotor radii. The analysis shows that the stability of tip vortices largely depends on the radial extent of the hub vorticity as well as on the type of vorticity distribution. As part......As a means of analysing the stability of the wake behind a multi-bladed rotor the stability of a multiplicity of helical vortices embedded in an assigned flow field is addressed. In the model the tip vortices in the far wake are approximated by infinitely long helical vortices with constant pitch...... and radius. The work is a further development of a model developed in Okulov (J. Fluid Mech., vol. 521, p. 319) in which the linear stability of N equally azimuthally spaced helical vortices was considered. In the present work the analysis is extended to include an assigned vorticity field due to root...

  1. ZBrush Professional Tips and Techniques

    CERN Document Server

    Gaboury, Paul

    2012-01-01

    Learn to work effectively and creatively with all versions of ZBrush! ZBrush is used by top artists in Hollywood to model and sculpt characters in such films as Avatar, Iron Man, and Pirates of the Caribbean. In addition, this amazing technology is also used in jewelry design, forensic science, aerospace, video games, toy creation, and the medical field. Written by Pixologic's in-house ZBrush expert Paul Gaboury, this full-color, beautifully illustrated guide provides you with the ultimate tips and tricks to maximize your use of all versions of ZBrush. Reveals numerous little-known tips and tr

  2. Office 2010 Visual Quick Tips

    CERN Document Server

    Gunter, Sherry Kinkoph

    2010-01-01

    Get more done in Office 2010 in less time with these Quick Tips!. Whether you're new to Microsoft Office or updating from older versions, this is the perfect resource to get you quickly up to speed on Office 2010. Every application is covered, including Word, Excel, PowerPoint, Outlook, and Publisher. Full-color screenshots and numbered steps clearly explain dozens of features and functions-while quick shortcuts, tips, and tricks help you save time and boost productivity. You'll also find great new ways to access and use some Office apps right from the Web.: Walks you through dozens of new fea

  3. Low NOx nozzle tip for a pulverized solid fuel furnace

    Science.gov (United States)

    Donais, Richard E; Hellewell, Todd D; Lewis, Robert D; Richards, Galen H; Towle, David P

    2014-04-22

    A nozzle tip [100] for a pulverized solid fuel pipe nozzle [200] of a pulverized solid fuel-fired furnace includes: a primary air shroud [120] having an inlet [102] and an outlet [104], wherein the inlet [102] receives a fuel flow [230]; and a flow splitter [180] disposed within the primary air shroud [120], wherein the flow splitter disperses particles in the fuel flow [230] to the outlet [104] to provide a fuel flow jet which reduces NOx in the pulverized solid fuel-fired furnace. In alternative embodiments, the flow splitter [180] may be wedge shaped and extend partially or entirely across the outlet [104]. In another alternative embodiment, flow splitter [180] may be moved forward toward the inlet [102] to create a recessed design.

  4. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; The oretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  5. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  6. A Framework to Estimate CO2 Leakage associated with Geological Storage in Mature Sedimentary Basins

    Science.gov (United States)

    Celia, M. A.; Bachu, S.; Gasda, S.

    2002-12-01

    Geological storage of carbon dioxide requires careful risk analysis to avoid unintended consequences associated with the subsurface injection. Most negative consequences of subsurface injection are associated with leakage of the injected CO2 out of the geological formation into which it is injected. Such leakage may occur through natural geological features, including fractures and faults, or it may occur through human-created pathways such as existing wells. Possible leakage of CO2 through existing wells appears to be especially important in mature sedimentary basins that have been explored intensively and exploited for hydrocarbon production. In the Alberta Basin of western Canada, more than 300,000 oil and gas wells have been drilled, while in the state of Texas in the United States, more than 1,500,000 wells have been drilled. Many of these wells have been abandoned, and the information available to describe their current state is highly variable and sometimes nonexistent. Because these wells represent possible direct conduits from the injection zone to the land surface, a comprehensive assessment of leakage potential associated with these wells needs to be pursued. Analysis of leakage potential associated with existing wells must combine a data mining component with a multi-level modeling effort to assess leakage potential in a probabilistic framework. Information available for existing wells must be categorized and analyzed, and general leakage characteristics associated with wells of varying properties must be quantified. One example of a realistic target formation is the Viking Formation in Alberta, which is overlain by a thick shale layer and contains hydrocarbon in some locations. The existence of hydrocarbon in the formation indicates that the overlying shale layer is an effective barrier to flow, and therefore this is a good candidate formation for CO2 storage. However, the formation and its cap rock are punctured by approximately 180,000 wells, with

  7. Ten tips for authors of scientific articles.

    Science.gov (United States)

    Hong, Sung-Tae

    2014-08-01

    Writing a good quality scientific article takes experience and skill. I propose 'Ten Tips' that may help to improve the quality of manuscripts for scholarly journals. It is advisable to draft first version of manuscript and revise it repeatedly for consistency and accuracy of the writing. During the drafting and revising the following tips can be considered: 1) focus on design to have proper content, conclusion, points compliant with scope of the target journal, appropriate authors and contributors list, and relevant references from widely visible sources; 2) format the manuscript in accordance with instructions to authors of the target journal; 3) ensure consistency and logical flow of ideas and scientific facts; 4) provide scientific confidence; 5) make your story interesting for your readers; 6) write up short, simple and attractive sentences; 7) bear in mind that properly composed and reflective titles increase chances of attracting more readers; 8) do not forget that well-structured and readable abstracts improve citability of your publications; 9) when revising adhere to the rule of 'First and Last' - open your text with topic paragraph and close it with resolution paragraph; 10) use connecting words linking sentences within a paragraph by repeating relevant keywords.

  8. Aperiodicity Correction for Rotor Tip Vortex Measurements

    Science.gov (United States)

    Ramasamy, Manikandan; Paetzel, Ryan; Bhagwat, Mahendra J.

    2011-01-01

    The initial roll-up of a tip vortex trailing from a model-scale, hovering rotor was measured using particle image velocimetry. The unique feature of the measurements was that a microscope was attached to the camera to allow much higher spatial resolution than hitherto possible. This also posed some unique challenges. In particular, the existing methodologies to correct for aperiodicity in the tip vortex locations could not be easily extended to the present measurements. The difficulty stemmed from the inability to accurately determine the vortex center, which is a prerequisite for the correction procedure. A new method is proposed for determining the vortex center, as well as the vortex core properties, using a least-squares fit approach. This approach has the obvious advantage that the properties are derived from not just a few points near the vortex core, but from a much larger area of flow measurements. Results clearly demonstrate the advantage in the form of reduced variation in the estimated core properties, and also the self-consistent results obtained using three different aperiodicity correction methods.

  9. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  10. The tip of the iceberg

    DEFF Research Database (Denmark)

    Bjørst, Lill Rastad

    2010-01-01

      Abstract: The tip of the iceberg: Ice as a nonhuman actor of the climate change debate   The global climate change debate has the Arctic as a core region of concern and ice has become a central aspect of discourses. This article discusses ice representations from six different contexts linked...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ... of Use | Links | Site Map Copyright © 2018 ... To help ensure current and accurate information, we do not permit copying but encourage linking ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... failure is severe, a TIPS may not be the best use and a different procedure may be needed to control your symptoms. They are also at risk for encephalopathy , which is an alteration of normal brain function that can lead to confusion. This is ...

  13. Food Allergy: Tips to Remember

    Science.gov (United States)

    ... or get better on their own. Outgrowing Food Allergies Most children outgrow their allergies to cow’s milk, egg, soy ... can help you learn when you or your child’s food allergies are resolving with time. Healthy Tips • Always ask ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening liver failure ...

  15. Assigning Effective Homework. Classroom Tips

    Science.gov (United States)

    American Federation of Teachers (NJ), 2010

    2010-01-01

    Each new school year brings high hopes, great expectations and challenges for both new and seasoned educators. The American Federation of Teachers (AFT) has developed a series called "Classroom Tips" to help educators start the year right and anticipate the year ahead. Over the past 40 years, most research studies on homework have found that…

  16. A Model for Determining Leakage in Water Distribution Systems

    OpenAIRE

    Stathis, Jonathan Alexander

    1998-01-01

    Leaks in pipe networks cause significant problems for utilities and water users in terms of lost revenue and interrupted service. In many cities the leakage is as high as forty percent. A water audit is carried out to assess system-wide leakage. However, to detect leakage at the level of a pipeline, a physical measurement technique is generally employed. For large cities the distribution piping length amounts to a few thousand miles. Therefore, the physical measurements can become tediou...

  17. Predicting casualties implied by TIPs

    Science.gov (United States)

    Trendafiloski, G.; Wyss, M.; Wyss, B. M.

    2009-12-01

    When an earthquake is predicted, forecast, or expected with a higher than normal probability, losses are implied. We estimated the casualties (fatalities plus injured) that should be expected if earthquakes in TIPs (locations of Temporarily Increased Probability of earthquakes) defined by Kossobokov et al. (2009) should occur. We classified the predictions of losses into the categories red (more than 400 fatalities or more than 1,000 injured), yellow (between 100 and 400 fatalities), green (fewer than 100 fatalities), and gray (undetermined). TIPs in Central Chile, the Philippines, Papua, and Taiwan are in the red class, TIPs in Southern Sumatra, Nicaragua, Vanatu, and Honshu in the yellow class, and TIPs in Tonga, Loyalty Islands, Vanatu, S. Sandwich Islands, Banda Sea, and the Kuriles, are classified as green. TIPs where the losses depend moderately on the assumed point of major energy release were classified as yellow; TIPs such as in the Talaud Islands and in Tonga, where the losses depend very strongly on the location of the epicenter, were classified as gray. The accuracy of loss estimates after earthquakes with known hypocenter and magnitude are affected by uncertainties in transmission and soil properties, the composition of the building stock, the population present, and the method by which the numbers of casualties are calculated. In the case of TIPs, uncertainties in magnitude and location are added, thus we calculate losses for a range of these two parameters. Therefore, our calculations can only be considered order of magnitude estimates. Nevertheless, our predictions can come to within a factor of two of the observed numbers, as in the case of the M7.6 earthquake of October 2005 in Pakistan that resulted in 85,000 fatalities (Wyss, 2005). In subduction zones, the geometrical relationship between the earthquake source capable of a great earthquake and the population is clear because there is only one major fault plane available, thus the epicentral

  18. Pressure control for minimizing leakage in water distribution systems

    Directory of Open Access Journals (Sweden)

    Nourhan Samir

    2017-12-01

    Full Text Available In the last decades water resources availability has been a major issue on the international agenda. In a situation of worsening scarcity of water resources and the rapidly increasing of water demands, the state of water losses management is part of man’s survival on earth. Leakage in water supply networks makes up a significant amount, sometimes more than 70% of the total water losses. The best practices suggest that pressure management is one of the most effective way to reduce the amount of leakage in a water distribution system. The approach presented in this study is aimed at modeling leakage as a function of pressure and pipe length, calibrating leakage coefficient, using fixed pressure reducing valves (PRVs to develop pressure fluctuation and developing WaterCAD scenarios to minimize leakage through the most effective settings of PRVs. This approach was applied on a district metered area (DMA in Alexandria, Egypt. The application of this approach produced some encouraging results, where the leakage through DMA was dropped by 37% for the best scenario. Thus, this approach is recommended as a decision support tool for determining a desirable solution for leakage reduction. Keywords: District measure area, Infrastructure leakage index, Leakage, Pressure management, Water supply networks

  19. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  20. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV-to-ground parasi......This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV...

  1. Vertebroplasty: Magnetic Resonance Findings Related to Cement Leakage Risk

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Y.H.; Han, D.; Cha, J.H.; Seong, C.K.; Kim, J.; Choi, Y.H. [Dept. of Radiology, Seoul Municipal Boramae Hospital, Seoul (Korea, republic of)

    2007-04-15

    Purpose: To find magnetic resonance (MR) findings predicting cement leakage in patients receiving percutaneous vertebroplasty (PVP) due to osteoporotic compression fractures. Material and Methods: MR was done in 43 patients (age 52-89 years) before PVP (56 vertebrae), which was done via a bipedicular approach with fluoroscopic monitoring. Shortly after the procedure, a non-contrast-enhanced computed tomography (CT) scan was done at the vertebroplasty sites for evaluation of bone cement leakage. The following MR findings of fractured vertebral bodies were retrospectively reviewed for correlation with leakage risk: severity of bone-marrow edema, presence of a T2-weighted low-signal-intensity line, percentage residual vertebral body height, presence of either a vacuum or cystic change within the vertebral body, and presence of a cortical disruption. Results: After PVP, cement leakage was detected in 35 vertebrae (62.5%). Leakage was most frequently observed in the anterior external vertebral venous plexus (46%). Cement leakage rate increased when there was a cortical disruption (P = 0.037), especially at the endplates, while it decreased when there was a vacuum or a cystic change within the fractured vertebra (P 0.019). Other MR findings were not related to the risk of cement leakage. Conclusion: The risk of cement leakage in PVP increases when MR shows cortical disruption in a fractured vertebral body, especially at the endplates. It decreases when MR shows a vacuum or cystic change within the body. Keywords Cement leakage, MR imaging, spine, vertebroplasty.

  2. Rotor aerodynamic power limits at low tip speed ratio using CFD

    DEFF Research Database (Denmark)

    Mikkelsen, Robert Flemming; Sarmast, Sasan; Henningson, Dan

    2014-01-01

    . In the present work we study in detail, using a CFD actuator line model, the flow behavior for rotors at small tip speed ratios. It is shown that the excessive swirl appearing towards the rotor center at small tip speed ratios generates vortex breakdown, causing a recirculating zone in the wake that limits...... the power yield of the rotor. The appearance of vortex breakdown has a similar effect on the flow behavior as the vortex ring state that usually appears at higher tip speed ratios. Limits to where vortex breakdown might occur with tip speed ratio and rotor loading as parameter are investigated and presented...... in the paper. The limits found correspond to well-known criterion for vortex breakdown onset for swirling flows in general. By applying a criterion for vortex breakdown in combination with the general momentum theory, the power performance always stays below the Betz limit....

  3. Mini-flared Kelman tip, reverse tip, and sidewinder tip with torsional phaco: a prospective randomized comparative study

    Directory of Open Access Journals (Sweden)

    Wilson Takashi Hida

    2015-02-01

    Full Text Available Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA, endothelial cell counts (ECC, and preoperative and 1-day postoperative central corneal thickness (CCT. Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE, and balanced salt solution volume (BSS. Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02 than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009. There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05. Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip.

  4. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...... in the size of the secret and observables, are cumbersome to compute and store, encode both the behavior of the system and assumptions about the attacker, and assume an input-output behavior of the system. For these reasons we propose to model the systemattacker scenario with Markovian models. We show...

  5. Understanding Magnetic Flux Leakage signals from gouges

    Energy Technology Data Exchange (ETDEWEB)

    Clapham, Lynann; Babbar, Vijay; Dien Chen, Jian [Applied Magnetics Group, Department of Physics, Queen' s University, Kingston, Ontario (Canada)], email: lynann@physics.queensu.ca; Alexander, Chris [Stress Engineering Services Inc., Houston, Texas (United States)

    2010-07-01

    Mechanical damage in pipelines is an important issue as it can lead to immediate or delayed failures. The magnetic flux leakage (MFL) method can be used to locate and characterize mechanical damage in pipelines. The purpose of this study is to get a better understanding of how MFL signals arise from pipeline gouges. Experimental MFL measurements were carried out on X60 grade pipe sections where a defect set of 10 gouges had been introduced; measurements were conducted on both internal and external pipe wall surface. Results showed that deformation and residual stress due to a gouge are mostly situated at the outer wall surface and that MFL measurements detected it from the inside and a model was developed to account for MFL axial dipole signal. This study brought new information on MFL signals and further work will be undertaken to completely understand how MFL signals arise from pipe gouge.

  6. Development of leakage monitoring system using radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. C.; Lee, D. S. [Seoil College, Seoul (Korea); Cho, Y. S. [Konyang University, Nonsan (Korea); Shin, S. K. [Sungkyunkwan Univ., Seoul (Korea)

    2000-04-01

    This study is to development the potable neutron back-scattering gauge for leakage and detecting liquid interface of an oil and liquid tank, using a radioisotopes. For this purpose, small sized, light weight potable gauge is to be designed as to develope neutron shielding mechanism, low power supply circuit, high voltage circuit, measurement circuit, and operating handle etc. The user will be able to set the duration of the time interval, the scale, the high voltage, the threshold, the channel window, the selection whether the data storage or not, the selection whether the scale, high voltage, threshold and window fix or not at any time. The counted pulse will be displayed with the numerical value and the line bar. The gauge will be able to connect to an IBM compatible PC via a serial port, power will be supplied by internal battery. 9 refs., 28 figs., 10 tabs. (Author)

  7. Parenting Tips: How to Improve Toddler Behavior

    Science.gov (United States)

    ... issues. To encourage listening and cooperation, follow these parenting tips. By Mayo Clinic Staff Life can be ... and a degree of routine. Consider these practical parenting tips. Make sure your displays of affection for ...

  8. Tips for Good Oral Health during Pregnancy

    Science.gov (United States)

    Tips for Good Oral Health During Pregnancy B elow are tips for taking care of your oral health while you are pregnant. Getting oral health care, practicing good oral hygiene, eating healthy foods, ...

  9. School Avoidance: Tips for Concerned Parents

    Science.gov (United States)

    ... Email Print Share School Avoidance: Tips for Concerned Parents Page Content ​School avoidance – sometimes called school refusal ... school bully) Actual physical harm Tips for Concerned Parents: As a first step, the management of school ...

  10. Postoperative non-steroidal anti-inflammatory drugs and colorectal anastomotic leakage. NSAIDs and anastomotic leakage.

    Science.gov (United States)

    Klein, Mads

    2012-03-01

    analyses identified NSAID treatment in the postoperative period as an individual risk factor for AL. Other risk factors identified were consistent with the available literature. The detrimental effect of the NSAIDs are possibly due to an effect on collagen metabolism leading to weakened tissue around the anastomosis and/or on the risk of thrombosis formation leading to more thromboses in the vessels supplying the anastomosis, thereby limiting anastomotic blood flow. In conclusion, the studies included in this thesis have elucidated some of the physiological and pathophysiological mechanisms involved in anastomotic healing and leakage, and furthermore have shown that the use of NSAIDs in the postoperative period increase the risk of AL in patients undergoing colorectal surgery with primary anastomosis. Based on the findings in these studies, and based on existing knowledge, it is recommended that NSAIDs be abandoned after colorectal resection with primary anastomosis. It should be investigated whether the NSAIDs are also harmful to other types of anastomoses and after other surgical procedures where early tissue healing is crucial.

  11. Leakage current-induced effects in the silicon microstrip and gas electron multiplier readout chain and their compensation method

    Science.gov (United States)

    Zubrzycka, W.; Kasinski, K.

    2018-04-01

    Leakage current flowing into the charge sensitive amplifier (CSA) is a common issue in many radiation detection systems as it can increase overall system noise, shift a DC baseline or even lead a recording channel to instability. The commonly known leakage current contributor is a detector, however other system components like wires or an input protection circuit may become a serious problem. Compensation of the leakage current resulting from the electrostatic discharge (ESD) protection circuit by properly sizing its components is possible only for a narrow temperature range. Moreover, the leakage current from external sources can be significantly larger. Many applications, especially High Energy Physics (HEP) experiments, require a fast baseline restoration for high input hit rates by applying either a low-value feedback resistor or a high feedback resistance combined with a pulsed reset circuit. Leakage current flowing in the feedback in conjunction with a large feedback resistance supplied with a pulsed reset results in a significant voltage offset between the CSA input and output which can cause problems (e.g. fake hits or instability). This paper shows an issue referred to the leakage current of the ESD protection circuit flowing into the input amplifier. The following analysis and proposed solution is a result of the time and energy readout ASIC project realization for the Compressed Baryonic Matter (CBM) experiment at FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. This chip is purposed to work with microstrip and gaseous detectors, with high average input pulses frequencies (250 kHit/s per channel) and the possibility to process input charge of both polarities. We present measurements of the test structure fabricated in UMC 180 nm technology and propose a solution addressing leakage current related issues. This work combines the leakage current compensation capabilities at the CSA level with high, controllable value of the amplifier

  12. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  13. Injector tip for an internal combustion engine

    Science.gov (United States)

    Shyu, Tsu Pin; Ye, Wen

    2003-05-20

    This invention relates to a the tip structure of a fuel injector as used in a internal combustion engine. Internal combustion engines using Homogeneous Charge Compression Ignition (HCCI) technology require a tip structure that directs fuel spray in a downward direction. This requirement necessitates a tip design that is capable of withstanding mechanical stresses associated with the design.

  14. Groundwater modeling to evaluate interaquifer leakage in the Floridan aquifer system near Hunter Army Airfield and Fort Stewart

    Science.gov (United States)

    Cherry, Gregory S.

    2011-01-01

    Simulations using a modified regional groundwater- flow model were used to determine the amount of leakage from the Upper Floridan aquifer (UFA) through the Lower Floridan confining unit (LFC) into the Lower Floridan aquifer (LFA) resulting from pumping about 1 million gallons per day at newly constructed LFA production wells at Hunter Army Airfield and Fort Stewart in coastal Georgia. Simulated steadystate drawdown at each of the LFA production wells closely matched observed drawdown during a 72-hour aquifer test with the observed water levels reaching steady-state by the end of the test period. However, simulated drawdown was greater than observed drawdown in the UFA because of the short duration of the aquifer test and the time required for groundwater movement through the LFC into the LFA. Steadystate simulations provide an estimate of leakage based on the long-term continuous operation of each production well. Results of model simulations indicate that interaquifer leakage accounts for 48 percent of the flow to the well at Hunter Army Airfield, and 98 percent of the flow to the well at Fort Stewart. Simulated results near the Hunter Army Airfield production well indicated that 65 percent of the leakage from the UFA to the LFA occurs within a 1-mile radius, whereas simulated results near the Fort Stewart production well indicated 80-percent leakage from the UFA to the LFA within the same radius. The greater amount of leakage to the production well near Fort Stewart can be attributed to the higher transmissivity of the UFA and higher vertical hydraulic conductivity in the LFC near the well.

  15. Relating Maxwell’s demon and quantitative analysis of information leakage for practical imperative programs

    International Nuclear Information System (INIS)

    Anjaria, Kushal; Mishra, Arun

    2017-01-01

    Shannon observed the relation between information entropy and Maxwell demon experiment to come up with information entropy formula. After that, Shannon’s entropy formula is widely used to measure information leakage in imperative programs. But in the present work, our aim is to go in a reverse direction and try to find possible Maxwell’s demon experimental setup for contemporary practical imperative programs in which variations of Shannon’s entropy formula has been applied to measure the information leakage. To establish the relation between the second principle of thermodynamics and quantitative analysis of information leakage, present work models contemporary variations of imperative programs in terms of Maxwell’s demon experimental setup. In the present work five contemporary variations of imperative program related to information quantification are identified. They are: (i) information leakage in imperative program, (ii) imperative multithreaded program, (iii) point to point leakage in the imperative program, (iv) imperative program with infinite observation, and (v) imperative program in the SOA-based environment. For these variations, minimal work required by an attacker to gain the secret is also calculated using historical Maxwell’s demon experiment. To model the experimental setup of Maxwell’s demon, non-interference security policy is used. In the present work, imperative programs with one-bit secret information have been considered to avoid the complexity. The findings of the present work from the history of physics can be utilized in many areas related to information flow of physical computing, nano-computing, quantum computing, biological computing, energy dissipation in computing, and computing power analysis. (paper)

  16. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  17. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  18. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  19. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  20. Results of Dynamic Calibration of Tipping-Bucket Rain Gauges

    Science.gov (United States)

    Kvicera, V.; Grabner, M.

    2009-04-01

    Experimental research in the Department of Frequency Engineering in the Czech Metrology Institute (CMI) in Prague, the Czech Republic, is focused on stability of received signal on terrestrial radio and optical paths. Rain can cause serious attenuation of electromagnetic waves in the frequency bands over 10 GHz. Therefore, our experimental research is also focused on our own meteorological measurement in the vicinity of experimental radio and optical paths. The heated tipping-bucket raingauge MR3H manufactured by Meteoservis, the Czech Republic, with the collector area of 500 cm2 and the rain amount per tip of 0.1 mm is used at CMI for the measurement of rainfall intensities. The time of tips is recorded with uncertainty of 0.1 second. The obtained time of tips are stored by PC and recorded on CD-ROM. It is generally known higher rainfall intensities measured by tipping-bucket rain gauges are underestimated. Therefore, after static calibration the tipping-bucket rain gauge was dynamically calibrated by water flowmeters. The Brooks FLOMEGA Flow Meters models 5882 and 3750 were used for the rain gauge calibration in the range from 2.6 mm/h to 530 mm/h. The used method of dynamic calibration of raingauges and our experience obtained will be described. The dependence of the measured rain intensity on the reference rain intensity (calibration curve) will be presented. Both the results obtained and the influence of dynamic calibration on our results concerning attenuation of electromagnetic waves due to rain will be discussed. Ministry of Education, Youth and Sports of the Czech Republic under the Project No. OC09076 supported the described work.

  1. High-Tip-Speed, Low-Loading Transonic Fan Stage. Part 1: Aerodynamic and Mechanical Design

    Science.gov (United States)

    Wright, L. C.; Vitale, N. G.; Ware, T. C.; Erwin, J. R.

    1973-01-01

    A high-tip-speed, low-loading transonic fan stage was designed to deliver an overall pressure ratio of 1.5 with an adiabatic efficiency of 86 percent. The design flow per unit annulus area is 42.0 pounds per square foot. The fan features a hub/tip ratio of 0.46, a tip diameter of 28.74 in. and operates at a design tip speed of 1600 fps. For these design conditions, the rotor blade tip region operates with supersonic inlet and supersonic discharge relative velocities. A sophisticated quasi-three-dimensional characteristic section design procedure was used for the all-supersonic sections and the inlet of the midspan transonic sections. For regions where the relative outlet velocities are supersonic, the blade operates with weak oblique shocks only.

  2. Effect of plastic prestrain on the crack tip constraint of pipeline steels

    International Nuclear Information System (INIS)

    Eikrem, P.A.; Zhang, Z.L.; Nyhus, B.

    2007-01-01

    Before and during operation, pipelines may suffer from plastic pre-deformation due to accidental loading, cold bending and ground movement. Plastic prestrain not only modifies steel's yield and flow properties but also influences its fracture performance. This paper focuses on the effect of prestrain history on crack driving force and crack tip constraint. A single-edge notched tension specimen has been selected for the study and the crack is assumed to exist before a prestrain history was applied. The results show that prestrain history has a strong effect on the crack tip stress field. A new parameter has been proposed to characterize the prestrain-induced crack tip constraint. For the same crack tip opening displacement level, prestrain history will elevate the crack tip stress field. The prestrain-induced constraint decreases with the increase of loading

  3. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  4. Failure analysis of leakage current in plastic encapsulated packages

    Science.gov (United States)

    Hu, S. J.; Cheang, F. T.

    1990-11-01

    Plastic encapsulated packages exhibit high leakage currents after a few hundred hours in the steam pressure pot test (SPP). The present study investigates two possible causes of leakage current. These are: (a) mold compound, (b) the polyimide tape used for co-planarity of lead frame fingers. The results of this study indicate that the leakage cur-rent is independent of the frame and is not caused by the mold compound. The data indicates that it is the ionic content and acrylic-based adhesive layer of the polyimide tape which cause the leakage current. To eliminate the leakage current, polyimide tape with low ionic content and non acrylic-based adhesive should be used.

  5. Study on Acoustic Catheter of Boiler Tube Leakage Monitoring Systems

    Science.gov (United States)

    Lv, Yongxing; Feng, Qiang

    Boiler tube leakage is the major reason of affecting the safe operation of the unit now, there are 3 methods of the "four tube" leakage detection: Traditional method, filtering method and acoustic spectrum analysis, acoustic spectrum analysis is the common method, but this method have low sensitivity and the sensor damage easily. Therewith, designed the special acoustic catheter with acoustic resonance cavity type, proved by experiments, the acoustic catheter with acoustic resonance cavity type can enhance leakage sound, can accurately extract leakage signals, has high sensitivity, and can avoid the effect of sensor by fire and hot-gas when the furnace is in positive pressure situation, reduce the installation and maintenance costs of the boiler tube leakage monitor system.

  6. Influence of Tip Clearance on Forced Convection Heat Transfer of a Finned Plate in a Duct

    International Nuclear Information System (INIS)

    Park, Haekyun; Chung, Bumjin

    2014-01-01

    Optimizations are required for a proper enhancement of cooling capability. An important phenomenological consideration is to be reveals for a finned plate in a duct. Due to the high friction near the fin region and low friction near the wall region, the forced flow tends to bypass from fin region to wall region. The bypass flow increases the net flow and enhances the heat transfer for a moderate tip clearance which is defined by the distance from the tip of the fin and the wall. Meanwhile for a large tip clearance, most of the flow bypasses and does not contribute the heat transfer and impairs the heat transfer. This study is a preliminary numerical study on the influence of the tip clearance on the heat transfer of the finned plate in a duct. The study aimed at supporting an experimental research exploring the phenomena for a very small tip clearance. Thus material properties and test conditions were chosen to meet the experimental conditions. It investigated the phenomena at Pr of 2,014 and ReS of 58.3. In order to investigate the small tip clearance phenomena, a simple numerical scheme was developed using a commercial CFD code. A case with the same experimental condition was tested using the numerical scheme and the error was about 12%. The results show the clear evidence of the flow bypass from the fin region to wall region, which impair the heat removal capacity of the finned plate in a duct. The study has the relevance with the reactor cavity cooling system performance enhancement activities in the VHTR. The numerical scheme will be tested for narrower and wider tip clearances and find an optimal tip clearance

  7. Design of modified annulus air sampling system for the detection of leakage in waste transfer line

    International Nuclear Information System (INIS)

    Deokar, U.V; Khot, A.R.; Mathew, P.; Ganesh, G.; Tripathi, R.M.; Srivastava, Srishti

    2018-01-01

    Various liquid waste streams are generated during the operation of reprocessing plant. The High Level (HL), Intermediate Level (IL) and Low Level (LL) liquid wastes generated, are transferred from reprocessing plant to Waste Management Facility. These respective waste streams are transferred through pipe-in-pipe lines along the shielded concrete trench. For detection of radioactive leakage from primary waste transfer line into secondary line, sampling of the annulus air between the two pipes is carried out. The currently installed pressurized annulus air sampling system did not have online leakage detection provision. Hence, there are chances of personal exposure and airborne activity in the working area. To overcome these design flaws, free air flow modified online annulus air sampling system with more safety features is designed

  8. Rubber contact mechanics: adhesion, friction and leakage of seals.

    Science.gov (United States)

    Tiwari, A; Dorogin, L; Tahir, M; Stöckelhuber, K W; Heinrich, G; Espallargas, N; Persson, B N J

    2017-12-13

    We study the adhesion, friction and leak rate of seals for four different elastomers: Acrylonitrile Butadiene Rubber (NBR), Ethylene Propylene Diene (EPDM), Polyepichlorohydrin (GECO) and Polydimethylsiloxane (PDMS). Adhesion between smooth clean glass balls and all the elastomers is studied both in the dry state and in water. In water, adhesion is observed for the NBR and PDMS elastomers, but not for the EPDM and GECO elastomers, which we attribute to the differences in surface energy and dewetting. The leakage of water is studied with rubber square-ring seals squeezed against sandblasted glass surfaces. Here we observe a strongly non-linear dependence of the leak rate on the water pressure ΔP for the elastomers exhibiting adhesion in water, while the leak rate depends nearly linearly on ΔP for the other elastomers. We attribute the non-linearity to some adhesion-related phenomena, such as dewetting or the (time-dependent) formation of gas bubbles, which blocks fluid flow channels. Finally, rubber friction is studied at low sliding speeds using smooth glass and sandblasted glass as substrates, both in the dry state and in water. The measured friction coefficients are compared to theory, and the origin of the frictional shear stress acting in the area of real contact is discussed. The NBR rubber, which exhibits the strongest adhesion both in the dry state and in water, also shows the highest friction both in the dry state and in water.

  9. A Numerical Analysis of Heat Transfer and Effectiveness on Film Cooled Turbine Blade Tip Models

    Science.gov (United States)

    Ameri, A. A.; Rigby, D. L.

    1999-01-01

    A computational study has been performed to predict the distribution of convective heat transfer coefficient on a simulated blade tip with cooling holes. The purpose of the examination was to assess the ability of a three-dimensional Reynolds-averaged Navier-Stokes solver to predict the rate of tip heat transfer and the distribution of cooling effectiveness. To this end, the simulation of tip clearance flow with blowing of Kim and Metzger was used. The agreement of the computed effectiveness with the data was quite good. The agreement with the heat transfer coefficient was not as good but improved away from the cooling holes. Numerical flow visualization showed that the uniformity of wetting of the surface by the film cooling jet is helped by the reverse flow due to edge separation of the main flow.

  10. Evaluation of Aircraft Wing-Tip Vortex Using PIV

    Science.gov (United States)

    Alsayed, Omer A.; Asrar, Waqar; Omar, Ashraf A.

    2010-06-01

    The formation and development of a wing-tip vortex in a near and extended near filed were studied experimentally. Particle image velocimetry was used in a wind tunnel to measure the tip vortex velocity field and hence investigate the flow structure in a wake of aircraft half-wing model. The purpose of this investigation is to evaluate the main features of the lift generated vortices in order to find ways to alleviate hazardous wake vortex encounters for follower airplanes during start and approach such that the increase in airport capacity can be achieved. First the wake structure at successive downstream planes crosswise to the axis of the wake vortices was investigated by measuring parameters such as core radius, maximum tangential velocities, vorticities and circulation distributions. The effect of different angles of attack setting on vortex parameters was examined at one downstream location. In very early stages the vortex sheet evolution makes the tip vortex to move inward and to the suction side of the wing. While the core radius and circulation distributions hardly vary with the downstream distance, noticeable differences for the same vortex parameters at different angles of attack settings were observed. The center of the wing tip vortices scatter in a circle of radius nearly equal to 1% of the mean wing chord and wandering amplitudes shows no direct dependence on the vortex strength but linearly increase with the downstream distance.

  11. The study of venous leakage in erectile dysfunction by cavernosometry and cavernosography: A case series in Sina Hospital

    Directory of Open Access Journals (Sweden)

    Beidaghian A

    2001-08-01

    Full Text Available Erectile dysfunction is an important problem for men and their families which has an organic cause in about 50 percent of cases. When there is a vasculogenic etiology for this defect, radiologic assessment is unavoidable. Cavernosometry and Cavernosography are ultimate procedures for diagnosis of venous leakage. There is no reliable data about this defects in Iran. The objective of this study was to determine the rate of venous leakage in patients with erectile dysfunction by Pharmarco-Cavernosometry and Cavernosography. In this case series study, 100 patient with erectile dysfunction who referred to radiologic ward in Sina hospital was selected and Pharmarco-Cavernosometry and Cavernosography were conducted for them. In Cavernosometry, after injection of Prostaglandin E1 and salin normal infusion into corpus covernosum, the pressure was determined. In cavernosography, diluted omnipaque was injected and venous leakage and other defects were recognized. Myoclinic's criteria was use for analysis of the results. Mean age of patients was 35.6±11.6. Most of the cases were in 20 to 40 age group. The frequency of venous leakage based on 50 mmHg reduction in pressure (from 150 mmHg, after 30 seconds discountinuance of normal salin infusion was 90 percent. This figure based on the ratio of Maintenance Flow Rate to Induced Flow Rate, was more than 92 percent. The frequency of venous leakage according to Cavernosography was 89 percent. There was no significant side effects in any of cases induced by procedures. The results of study, shows the high prevalence of venous leakage in patients referring for erectile dysfunction.

  12. Leakage pattern of linear accelerator treatment heads from multiple vendors

    International Nuclear Information System (INIS)

    Lonski, P.R.; Taylor, M.L.; Franich, R.D.; Harty, P.; Clements, N.; Kron, T.

    2011-01-01

    Full text: Patient life expectancy post-radiotherapy is becoming longer. Therefore, secondary cancers caused by radiotherapy treatment have more time to develop. Increasing attention is being given to out-of-field dose resulting from scatter and accelerator head leakage. Dose leakage from equivalent positions on Varian600C, Varian21-X, Siemens Primus and Elekta Synergy-II linacs were measured with TLD 1 00 H dosimeter chips and compared. Treatment parameters such as field size and beam energy were altered. Leakage doses are presented as a percentage of the dose to isocentre (5 Gy). Results illustrate significant variations in leakage dose between linac models where no model emits consistently lower amounts of radiation leakage for all treatment parameters. Results are shown below. Leakage through the collimator assembly in different units is varying as a function of location and unit design by more than a factor of 10. Differences are more pronounced in comparing Varian or Elekta models, which are fitted with an additional collimator separate from the MLC leaves, to the Siemens model, which uses MLC leaves as its only secondary collimator. Further measurements are currently being taken at the patient plane with a directional detector system to determine the spatial distribution of high leakage sources.

  13. Windows 8 visual quick tips

    CERN Document Server

    McFedries, Paul

    2012-01-01

    Easy-in, easy-out format covers all the bells and whistles of Windows 8 If you want to learn how to work smarter and faster in Microsoft's Windows 8 operating system, this easy-to-use, compact guide delivers the goods. Designed for visual learners, it features short explanations and full-color screen shots on almost every page, and it's packed with timesaving tips and helpful productivity tricks. From enhancing performance and managing digital content to setting up security and much more, this handy guide will help you get more out of Windows 8. Uses full-color screen shots and short, step-by-

  14. Twitter Tips, Tricks, and Tweets

    CERN Document Server

    McFedries, Paul

    2010-01-01

    Maximize your fun and boost your productivity with this updated, full-color guide to tantalizing Twitter tips!. The popularity of Twitter continues to soar, and is fast becoming the most popular social networking site online. Whether you're looking to learn how to set up an account for the first time or are on the prowl for some cool third-party Twitter apps, this full-color guide will boost your entire Twitter experience. Allowing you to communicate with fellow Twitters within a 140-character limit, this fun and fascinating social networking tool is easier than maintaining a blog and quicker

  15. Erosion of buffer caused by groundwater leakages

    International Nuclear Information System (INIS)

    Autio, J.; Hanana, K.; Punkkinen, O.; Koskinen, K.; Olin, M.

    2010-01-01

    Document available in extended abstract form only. In the Finnish HLW disposal concept the most important properties of the bentonite clay being considered for these isolation purposes are its thermal behaviour, low hydraulic conductivity, diffusion limited transport, rheology, plasticity, sufficient swelling potential, and exchange capacity. All of these properties depend critically on bentonite density; therefore, any potential mass loss or redistribution events must be well characterized. One such event or process is the erosion of bentonite by flowing groundwater and the groundwater flowing in newly formed channels, in special. Mechanical erosion during the operational phase, due to high groundwater pressure gradients in open excavations, has been identified as a critical issue in TKS-2006 and SR-Can. This work addresses the mechanical erosion of bentonite by fluid shear. In order for buffer erosion to occur three processes must take place: detachment, entrainment, and transport. These processes are followed by the settling of the material and redistribution of buffer mass. Erosion begins with the detachment of a particle from surrounding material, which requires the application of shear forces greater than the attractive force between the particle and parent structure. Entrainment is the process by which the eroding medium lifts the detached particle into the flow. The most important aspect in entrainment is transfer of fluid's inertial forces via surface friction to particles' inertial forces, which, in turn, must overcome the frictional resistance between the particle and its surroundings. Factors influencing frictional resistance include gravity, particle mass, saturation degree of parent structure, composition of water present in parent structure, particle size, and surface roughness. Recent erosion tests, whereby water flow was directed over compacted bentonite blocks or through a system of bentonite pellets, have indicated that bentonite erodes

  16. Basin-Scale Leakage Risks from Geologic Carbon Sequestration: Impact on Carbon Capture and Storage Energy Market Competitiveness

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Catherine; Fitts, Jeffrey; Wilson, Elizabeth; Pollak, Melisa; Bielicki, Jeffrey; Bhatt, Vatsal

    2013-03-13

    incentives, such as a carbon tax, are needed for coal combustion with CCS to gain market share. In another part of the project we studied the role of geochemical reactions in affecting the probability of CO{sub 2} leakage. A basin-scale simulation tool was modified to account for changes in leakage rates due to permeability alterations, based on simplified mathematical rules for the important geochemical reactions between acidified brines and caprock minerals. In studies of reactive flows in fractured caprocks, we examined the potential for permeability increases, and the extent to which existing reactive transport models would or would not be able to predict it. Using caprock specimens from the Eau Claire and Amherstburg, we found that substantial increases in permeability are possible for caprocks that have significant carbonate content, but minimal alteration is expected otherwise. We also found that while the permeability increase may be substantial, it is much less than what would be predicted from hydrodynamic models based on mechanical aperture alone because the roughness that is generated tends to inhibit flow.

  17. Junction leakage measurements with micro four-point probes

    DEFF Research Database (Denmark)

    Lin, Rong; Petersen, Dirch Hjorth; Wang, Fei

    2012-01-01

    We present a new, preparation-free method for measuring the leakage current density on ultra-shallow junctions. The junction leakage is found by making a series of four-point sheet resistance measurements on blanket wafers with variable electrode spacings. The leakage current density is calculated...... using a fit of the measured four-point resistances to an analytical two-sheet model. The validity of the approximation involved in the two-sheet model is verified by a comparison to finite element model calculations....

  18. Quantum error prevention and leakage elimination for quantum dots

    Science.gov (United States)

    Pegahan, Saeed; Byrd, Mark S.; Reddy Chinni, Karthik

    2015-03-01

    Decoherence-free, or noiseless subsystems, are used to encode spin qubits in quantum dots in order to achieve universal quantum computing using only the exchange interaction. We investigate the use of dynamical decoupling controls for the purposes of eliminating leakage for a logical qubit encoded using three physical qubits. These leakage elimination operators (LEOs) can be used to eliminate all leakage errors using exchange interactions between the physical spin qubits. Depending on the encoding and the decoupling control, different types of errors can be eliminated. We show several different possible controls and the consequential noise reduction for different encodings as well as our general method for determining the effectiveness of these pulses.

  19. Rebleeding rates following TIPS for variceal hemorrhage in the Viatorr era: TIPS alone versus TIPS with variceal embolization.

    Science.gov (United States)

    Gaba, Ron C; Bui, James T; Cotler, Scott J; Kallwitz, Eric R; Mengin, Olga T; Martinez, Brandon K; Berkes, Jaime L; Carrillo, Tami C; Knuttinen, M Grace; Owens, Charles A

    2010-08-06

    To compare rebleeding rates following treatment of variceal hemorrhage with TIPS alone versus TIPS with variceal embolization in the covered stent-graft era. In this retrospective study, 52 patients (M:F 29:23, median age 52 years) with hepatic cirrhosis and variceal hemorrhage underwent TIPS insertion between 2003 and 2008. Median Child-Pugh and MELD scores were 8.5 and 13.5. Generally, 10-mm diameter TIPS were created using covered stent-grafts (Viatorr; W.L. Gore and Associates, Flagstaff, AZ). A total of 37 patients underwent TIPS alone, while 15 patients underwent TIPS with variceal embolization. The rates of rebleeding and survival were compared. All TIPS were technically successful. Median portosystemic pressure gradient reductions were 13 versus 11 mmHg in the embolization and non-embolization groups. There were no statistically significant differences in Child-Pugh and MELD score, or portosystemic pressure gradients between each group. A trend toward increased rebleeding was present in the non-embolization group, where 8/37 (21.6%) patients rebled while 1/15 (6.7%) patients in the TIPS with embolization group rebled (P = 0.159) during median follow-up periods of 199 and 252 days (P = 0.374). Rebleeding approached statistical significance among patients with acute hemorrhage, where 8/32 (25%) versus 0/14 (0%) rebled in the non-embolization and embolization groups (P = 0.055). A trend toward increased bleeding-related mortality was seen in the non-embolization group (P = 0.120). TIPS alone showed a high incidence of rebleeding in this series, whereas TIPS with variceal embolization resulted in reduced recurrent hemorrhage. The efficacy of embolization during TIPS performed for variceal hemorrhage versus TIPS alone should be further compared with larger prospective randomized trials.

  20. Percutaneous transhepatic biliary drainage through the normal duct in patients with post-operative bile leakage

    International Nuclear Information System (INIS)

    Lee, Hyun; Kim, Young Hwan; Kim, Yong Joo

    2004-01-01

    To evaluate the technical feasibility and clinical efficacy of percutaneous transhepatic biliary drainage (PTBD) through the normal duct in patients with post-operative bile leakage. From January 1998 to December 2003, fourteen patients (male: 12, female: 2, mean age: 56) with biliary leak after laparoscopic cholecystectomy (n = 5), T-tube removal (n = 5), choledochojejunostomy due to small bowel perforation (n = 1), right lobectomy (n = 1), laparoscopic adrenalectomy (n = 1), and subtotal gastrectomy (n = 1) were treated by means of PTBD; this was performed with the two-step approach. The central bile duct was cannulated using a 21-G Chiba needle to map the intrahepatic biliary tree. An 8.5-F drainage catheter tip was positioned at the CBD after puncturing peripheral bile duct with an additional Chiba needle. We evaluated the technical feasibility, the procedure-related complications, clinical efficacy and the duration of catheter placement. PTBD of the normal duct with the two-step approach was successful in all but two cases. In these two cases, the two-step approach was failed due to the rapid disappearance of the targeted peripheral duct, and this was the result caused by biloportal fistula. PTBD was performed through the central bile duct in one patient, and through the remnant cystic duct in one patient. There were no procedure-related complications except for mild abdominal pain in seven patients. Bile leakage was demonstrated on cholangiogram in 10 of 14 patients; this occurred at the T-tube exit site (n = 4), cystic duct stump (n = 2), choledochojejunostomy site (n = 1), resection margin of liver (n = 1), caudate lobe (n = 1), and GB bed (n = 1). In 13 patients, the biliary leak stopped after drainage (mean duration: 32.1 days). In one patient, surgical management was performed one day after PTBD due to the excessive amount of bile leakage. PTBD is a technically feasible and clinically efficacious treatment for post-operative bile leakage, and it can

  1. Measuring Fan-Blade-Tip Displacements

    Science.gov (United States)

    Berry, Robert F., Jr.

    1988-01-01

    Magnets and Hall-effect transducers used to monitor tip-to-shroud clearances. Mounting permanent magnet in end of fan blade and monitoring tip-to-shroud distance by use of output of Hall-effect transducers affixed to surface of shroud. Transducers provide real-time information. By placing magnets in each fan-blade tip, complete set monitored sequentially as each blade rotates past sensor. Application in many rotating machines, providing surrounding materials nonmagnetic and temperatures not severe.

  2. Environmental and artificial tracers in investigations of leakages to salt mines

    International Nuclear Information System (INIS)

    Zuber, A.; Grabczak, J.; Kolonko, M.

    1978-01-01

    The paper presents five years experience in investigations of the origin of waters in the Wapno mine, exploiting salt in a Zechstein dome, in the North-western Poland. Tritium and 14 C measurements showed young infiltration waters in leakages at the third level of the mine. Stable isotope determinations showed a considerable shift of value from the precipitation line, both on activity and concentration scales. In spite of this shift, it was possible to distinguish infiltration waters from connate ones appearing at deeper mine levels. In 1976 and 1977 the flow rates of leakages increased and the mineralization decreased. Tritium and 14 C contents did not change at that time showing that at the initial stages of flooding the origin of water in the leakages was not changed. First results of isotope investigations in the Klodawa mine, situated in another Zechstein salt dome in the Central Poland, showed connate waters. Observations performed in the Wieliczka salt mine, situated in Miocen formations in the Southern Poland, showed old waters originating from the surrounding formations. Their stable isotope composition shows that recharge took place in a cooler climate. The 14 C content of these waters is 1 to 2% of modern carbon. The experimental procedure used for the determination of the isotopic composition of highly mineralized brines is also described. (orig.) [de

  3. Competitiveness and carbon leakages in industry under asymmetric climate policy

    International Nuclear Information System (INIS)

    Demailly, D.

    2008-02-01

    This research aims at studying how to predict competitiveness loss for an industry submitted to an asymmetric carbon constraint, and carbon leakages, whether high losses and important leakages might be feared, and which policies can be used to mitigate these losses and escapes. The author analyses and comments the content of four articles dealing with: the impact on competitiveness, revenue distribution and economic efficiency of a change in the allocation rules for EU greenhouse gas allowances; the relationship between allocation of CO 2 allowances and competitiveness in the case of the European iron and steel industry; CO 2 abatement, competitiveness and leakage in the European cement industry under EU ETS; and leakage from climate policies and border tax adjustment (lessons from a geographic model of the cement industry). Then, the author combines several approaches to study the cement and steel industries

  4. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    , we use a randomized encoding and develop a method to securely refresh these encodings even in the presence of leakage. We then show that our encoding scheme exhibits an efficient additive homomorphism which can be used to protect important cryptographic tasks such as identification, signing......We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third......, the randomness that is used for certain operations comes from a simple (non-uniform) distribution. As a fundamental building block, we construct a scheme to store a cryptographic secret such that it remains information theoretically hidden, even given arbitrary continuous leakage from the storage. To this end...

  5. Prediction of leakage in the fixed mechanical seal

    Directory of Open Access Journals (Sweden)

    Asheichik Anatoly A.

    2017-01-01

    Full Text Available The questions of influence of the shape of contact surfaces on leakages through rubber seals in fixed connection of subassemblies are considered in the article. It is known from practice of operation of seals of various designs that the shape of contact surfaces and consequently also the shape of diagram of stresses in a contact zone considerably influences on value of leaks Linking leakage magnitude and distribution of contact stresses enables, firstly, more precisely calculate the amount of leakage for existing seals, and, secondly, to optimize the shape of the seals in their design in each case. As the result of experimental studies on the introduction of the rubber gasket ring fixed indenters different profiles found that by optimizing the shape of the indenter magnitude of leakage can be reduced by 10 times.

  6. Magnetic leakage shield of septum magnet for SPring-8 synchrotron

    International Nuclear Information System (INIS)

    Abe, Hiroshi; Aoki, Tsuyoshi; Fukami, Kenji

    1997-01-01

    This paper describes magnetic field measurements of the prototype septum magnet and countermeasure for reducing the leakage magnetic fields in the incidence and the extraction parts of the SPring-8 synchrotron. We studied and developed 'leakage magnetic shield' on the basis of the tests data got in these measurements. Consequentially, it succeeded in reducing effects of the leakage field to about 50% by installing the shield board in the magnet main body. Then, it was possible to manufacture the magnet which sufficiently held the effect of the leakage field for the electron and positron beam. In this examination, we confirmed the reproduction with the magnetic field distribution of the magnet measured in the manufacturer. We developed and produced of the septum magnets which were carried out determination of the shapes of the magnetic shielding. (author)

  7. Identification of sources and causes of leakage on a zoned earth dam in northern Taiwan: Hydrological and isotopic evidence

    International Nuclear Information System (INIS)

    Peng, T.-R.; Wang, C.-H.

    2008-01-01

    Seepage through an earth dam body must be regulated as a well-planned process, if it is not properly managed, the abnormal seepage may cause dam failure. This study employed stable isotopic and statistical methods to identify the source and cause of an abnormal leakage on the zoned earth dam of the Xin-Shan reservoir located in northern Taiwan. Water samples from the dam area over a 2-a period were collected and analyzed for their stable O and H isotope compositions. In addition, a 4-a period of hydrological data, including rainfall, reservoir level, well level, seepage of filter drainage and leakage, were statistically analyzed with a stepwise multiple regression approach. Both the stable isotopic and hydrological results indicate that the abnormal leakage on the dam shell comes from the filter drainage in the dam. The reason for abnormal leakage is due to unexpected and significant precipitation-sourced water flowing into the dam's body. The dam filter fails to drain out the incoming water sufficiently, thus generating the abnormal seepage. In addition, the defect in the dam filter may also cause the drainage filter to drain off reservoir seepage inadequately. Therefore, it is suggested that checking the filter function and preventing excessive precipitation-sourced water from flowing into the dam are the two top priorities for the follow-up remedial strategy of the dam

  8. Risk of Leakage versus Depth of Injection in Geological Storage

    OpenAIRE

    Celia, Michael A.; Nordbotten, Jan Martin; Bachu, Stefan; Dobossy, Mark E.; Court, Benjamin

    2009-01-01

    One of the outstanding challenges for large-scale CCS operations is to develop reliable quantitative risk assessments with a focus on leakage of both injected CO2 and displaced brine. A critical leakage pathway is associated with the century-long legacy of oil and gas exploration and production, which has led to many millions of wells being drilled. Many of those wells are in locations that would otherwise be excellent candidates for CCS operations, especially across many parts of North Ameri...

  9. An alternative treatment for anastomotic leakage after oesophageal resection

    DEFF Research Database (Denmark)

    Damm, P; Hoffmann, J.

    1988-01-01

    An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity.......An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity....

  10. Probing Access Resistance of Solid-state Nanopores with a Scanning Probe Microscope Tip.

    Science.gov (United States)

    Hyun, Changbae; Rollings, Ryan; Li, Jiali

    2012-02-06

    An apparatus that integrates solid-state nanopore ionic current measurement with a Scanning Probe Microscope has been developed. When a micrometer-scale scanning probe tip is near a voltage biased nanometer-scale pore (10-100 nm), the tip partially blocks the flow of ions to the pore and increases the pore access resistance. The apparatus records the current blockage caused by the probe tip and the location of the tip simultaneously. By measuring the current blockage map near a nanopore as a function of the tip position in 3D space in salt solution, we estimate the relative pore resistance increase due to the tip, ΔR/R(0), as a function of the tip location, nanopore geometry, and salt concentration. The amplitude of ΔR/R(0) also depends on the ratio of the pore length to its radius as Ohm's law predicts. When the tip is very close to the pore surface, ~10 nm, our experiments show that ΔR/R(0) depends on salt concentration as predicted by the Poisson and Nernst-Planck equations. Furthermore, our measurements show that ΔR/R(0) goes to zero when the tip is about five times the pore diameter away from the center of the pore entrance. The results in this work not only demonstrate a way to probe the access resistance of nanopores experimentally, they also provide a way to locate the nanopore in salt solution, and open the door to future nanopore experiments for detecting single biomolecules attached to a probe tip.

  11. Probing access resistance of solid-state nanopores with a scanning-probe microscope tip.

    Science.gov (United States)

    Hyun, Changbae; Rollings, Ryan; Li, Jiali

    2012-02-06

    An apparatus that integrates solid-state nanopore ionic current measurement with a scanning-probe microscope is developed. When a micrometer-scale scanning-probe tip is near a voltage-biased nanometer-scale pore (10–100 nm), the tip partially blocks the flow of ions to the pore and increases the pore access resistance. The apparatus records the current blockage caused by the probe tip and the location of the tip simultaneously. By measuring the current blockage map near a nanopore as a function of the tip position in 3D space in salt solution, the relative pore resistance increases due to the tip and ΔR/R0 is estimated as a function of the tip location, nanopore geometry, and salt concentration. The amplitude of ΔR/R0 also depends on the ratio of the pore length to its radius as Ohm's law predicts. When the tip is very close to the pore surface, ≈10 nm, experiments show that ΔR/R0 depends on salt concentration as predicted by the Poisson and Nernst–Planck equations. Furthermore, the measurements show that ΔR/R0 goes to zero when the tip is about five times the pore diameter away from the center of the pore entrance. The results in this work not only demonstrate a way to probe the access resistance of nanopores experimentally; they also provide a way to locate the nanopore in salt solution, and open the door to future nanopore experiments for detecting single biomolecules attached to a probe tip. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Experimental framework to study tip vortex interactions in multirotor wakes

    Science.gov (United States)

    Yao, Rongnan; Araya, Daniel

    2017-11-01

    We present an experimental study to compare the dynamic characteristics of tip vortices shed from a propeller in a crossflow to similar characteristics of an isolated vortex column generated in a closed system. Our aim is to evaluate the feasibility of using this simple isolated system to study the more complicated three-dimensional vortex interactions inherent to multirotor wakes, where the local unsteadiness generated by one rotor can strongly impact the performance of nearby rotors. Time-resolved particle image velocimetry is used to measure the velocity field of the propeller wake flow in a wind tunnel and the vortex column in a water tank. Specific attention is placed on analyzing the observed vortex core precession in the isolated system and comparing this to characteristic tip-vortex wandering phenomenon.

  13. Characteristics of premixed flames stabilized in an axisymmetric curved-wall jet burner with tip modification

    KAUST Repository

    Kim, Daejoong

    2009-11-10

    The stabilization characteristics of premixed flames in an axisymmetric curved-wall jet burner have been experimentally investigated. This burner utilized the Coanda effect on top of a burner tip. The initially spherical burner tip was modified to a flat tip and a concave tip in order to improve flame stabilization by providing enough space for flow recirculation above the burner tip region. The flow characteristics have been visualized using a schlieren technique. Small-scale turbulence structure has been observed mainly in the interaction jet region (located downstream of the recirculation region) for large jet velocity (Reynolds number >11,500). An appreciable amount of air entrainment was exhibited from the half-angle of the jet spread, approximately 20. The averaged planar laser-induced fluorescence images of the flames for this large velocity demonstrated that the strong signal of OH radicals, representing reaction zones, existed in the recirculation zone, while it was weak in the interaction jet region due to intermittency and local extinction by the generation of small scale turbulence. The OH radical signals strengthened again in the merged jet region (downstream of the interaction jet region). In extreme cases of Reynolds number over 19,000, a unique flame exhibiting OH radicals only in the recirculation zone was observed for the concave tip. The flame stabilization has been mapped by varying jet velocity and equivalence ratio, and the result showed that the stabilization characteristics were improved appreciably from the initial spherical tip design, especially for rich mixtures. The flow fields measured by a laser Doppler velocimetry confirmed the existence of recirculation zone and the expansion of the recirculation zones for the modified tips. The temperature profile measured by a coherent anti-Stokes Raman spectroscopy exhibited an intermittent nature, especially near the recirculation zone.

  14. International Market Leakage from China’s Forestry Policies

    Directory of Open Access Journals (Sweden)

    Xin Hu

    2014-11-01

    Full Text Available Carbon leakage can be a problem when seeking to reduce carbon emissions through forest policy. International market leakage is mainly caused by supply and demand imbalances in the timber market. This paper selects China, which is implementing forestry policy changes, as the research object. We begin by offering a brief analysis of China’s forestry policy changes, such as the logging quota and Six Key Forestry Programs to determine whether those policies affect timber supply. Second, through the use of three shock variables, carbon leakage is simulated under different scenarios by the Global Trade Analysis Project (GTAP model. The results reveal that the magnitude of leakage caused by implementing China’s forestry policies is between 79.7% and 88.8% with carbon leakage mainly displaced to Russia, Southeast Asia, and the EU. Two effective scenarios for reducing market leakage are presented: forest tenure reform and fast growing forest projects to improve domestic timber production, and raising tariffs on timber imports to reduce imports.

  15. 4D ERT Monitoring of Subsurface Water Pipe Leakage During a Controlled Field Experiment

    Science.gov (United States)

    Inauen, C.; Chambers, J. E.; Wilkinson, P. B.; Meldrum, P.; Swift, R. T.; Uhlemann, S.; Gunn, D.; Dashwood, B.; Taxil, J.; Curioni, G.

    2016-12-01

    Locating and delineating leakage from subsurface pipelines is an important task for civil engineers. 4D Electrical Resistivity Tomography (ERT) allows changes in subsurface resistivity to be imaged at a high spatial and temporal resolution in a minimally invasive manner. It is therefore a promising tool to supplement conventional point-sensing techniques to monitor subsurface flow processes. To assess the efficacy of ERT for pipe leakage monitoring several controlled leak experiments were carried out at a test site in Blagdon, Bristol, UK. To simulate the leak, a plastic pipe with a hole was buried below a flat, grassed area at a depth of 0.7 m, representing a standard UK mains water pipe installation. The water table at the site lies well below the surface meaning that the experiment took entirely place in the vadose zone, where changes in resistivity are primarily sensitive to water content variations. The ERT array covered an area of 6.5m x 6.5m around the leak location. Data acquisition was carried out with the BGS PRIME (Proactive Infrastructure Monitoring and Evaluation) system, which facilitates remote scheduling and autonomous ERT data collection and transmission. To obtain the resistivity changes of the subsurface a 4D inversion was carried out using a Gauss-Newton approach with spatial and temporal smoothness constraints. We were able to reliably observe the onset, spread and cessation of the leakage. Measurements from in-situ soil sensors at several depths above and below the leak complemented the ERT data and allowed us to assess their reliability and directly relate them to hydrogeological processes. Moreover, through experimental tests with soil samples from the test area, a Waxman-Smits relation was obtained to directly convert the changes in electrical resistivity to gravimetric soil moisture content. With future experiments on the test site more work is planned towards survey optimization, automated processing and tracking of leakage plumes.

  16. Atmospheric leakage and condensate production in NASA's biomass production chamber. Effect of diurnal temperature cycles

    Science.gov (United States)

    Wheeler, Raymond M.; Drese, John H.; Sager, John C.

    1991-01-01

    A series of tests were conducted to monitor atmospheric leakage rate and condensate production in NASA's Biomass Production Chamber (BPC). Water was circulated through the 64 plant culture trays inside the chamber during the tests but no plants were present. Environmental conditions were set to a 12-hr photoperiod with either a matching 26 C (light)/20 C (dark) thermoperiod, or a constant 23 C temperature. Leakage, as determined by carbon dioxide decay rates, averaged about 9.8 percent for the 26 C/20 C regime and 7.3 percent for the constant 23 C regime. Increasing the temperature from 20 C to 26 C caused a temporary increase in pressure (up to 0.5 kPa) relative to ambient, while decreasing the temperature caused a temporary decrease in pressure of similar magnitude. Little pressure change was observed during transition between 23 C (light) and 23 C (dark). The lack of large pressure events under isothermal conditions may explain the lower leakage rate observed. When only the plant support inserts were placed in the culture trays, condensate production averaged about 37 liters per day. Placing acrylic germination covers over the tops of culture trays reduced condensate production to about 7 liters per day. During both tests, condensate production from the lower air handling system was 60 to 70 percent greater than from the upper system, suggesting imbalances exist in chilled and hot water flows for the two air handling systems. Results indicate that atmospheric leakage rates are sufficiently low to measure CO2 exchange rates by plants and the accumulation of certain volatile contaminants (e.g., ethylene). Control system changes are recommended in order to balance operational differences (e.g., humidity and temperature) between the two halves of the chamber.

  17. Cause elucidation of sodium leakage incident at `Monju` reactor. Vibration of thermometer due to fluid force

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Koji; Wada, Yusaku; Morishita, Masaki; Yamaguchi, Akira; Ichimiya, Masakazu [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1997-01-01

    This is a report of summarized results of investigation and analysis on fracture of thermometer which is direct reason of sodium leakage incident at the second main cooling system of fast breeder reactor `Monju`. Various surveys such as on various damage factors, on flowing power vibrational features containing flowing power vibrational test of thermometer, on evaluation of high cycle fatigue due to flowing power vibration and details on propagation of and fracture due to fatigue crack, on why only said thermometer damaged, and so forth were executed. As results of these examinations, a decision was arrived that high cycle fatigue due to vibration formed by fluid force (fluid force vibration) was a direct cause of the thermometer damage. (G.K.)

  18. Modeling CO2 Gas Migration of Shallow Subsurface CO2 Leakage Experiments

    Science.gov (United States)

    Porter, M. L.; Plampin, M. R.; Pawar, R.; Illangasekare, T. H.

    2013-12-01

    Leakage of injected CO2 into shallow subsurface aquifers or back into the atmosphere at geologic carbon sequestration sites is a risk that must be minimized. One potential CO2 leakage pathway involves the transport of dissolved CO2 into a shallow aquifer where the CO2 exsolves, forming a free CO2 gas phase that subsequently migrates through the aquifer. In order to reduce the negative effects of CO2 exsolution, it is important to fully understand each of the processes controlling the movement CO2, as well as the effects of aquifer heterogeneity on the overall fate and transport of CO2. In this work, we present multiphase flow simulations of intermediate scale CO2 exsolution experiments. The multiphase flow simulations were carried out using the Finite Element Heat and Mass Transfer code (FEHM) developed at Los Alamos National Laboratory. Simulations were first designed to model experiments conducted in two different homogeneous packed sands. PEST (Parameter Estimation and Uncertainty Analysis) was used to optimize multiphase flow parameters (i.e., porosity, permeability, relative permeability, and capillary pressure) within FEHM. The optimized parameters were subsequently used to model heterogeneous experiments consisting of various packing configurations using the same sands. Comparisons of CO2 saturation between experiments and simulations will be presented and analyzed.

  19. Single Phase Transformer-less Buck-Boost Inverter with Zero Leakage Current for PV Systems

    DEFF Research Database (Denmark)

    Mostaan, Ali; Abdelhakim, Ahmed; N. Soltani, Mohsen

    2017-01-01

    In this paper, a novel single-stage single-phase transformer-less buck-boost inverter is proposed, in which a reduced number of passive components is used. The proposed inverter combines the conventional buck, boost, and buck-boost converters in one converter in order to obtain a sinusoidal output...... voltage. In the proposed inverter, the input DC source and the load or grid have the same ground. Therefore, the leakage current problem in photovoltaic (PV) systems is eliminated. Furthermore, the proposed inverter supports the bi-directional power flow capability and it can inject reactive power...

  20. The tip of the iceberg

    DEFF Research Database (Denmark)

    Bjørst, Lill Rastad

    2010-01-01

      Abstract: The tip of the iceberg: Ice as a nonhuman actor of the climate change debate   The global climate change debate has the Arctic as a core region of concern and ice has become a central aspect of discourses. This article discusses ice representations from six different contexts linked...... to the 2009 United Nations Climate Change Conference (COP15) in Copenhagen. The author argues that even though the discussions often seem to be centred on ice alone, the latter gets inscribed in narratives and metaphors which have wider implications for how the Arctic and its Indigenous peoples...... are represented. Ice becomes a nonhuman actor, framing the discussions, acting in specific ways, and linking hybrid networks. Indeed it is used in diverse platforms by scientists, politicians, governments, NGOs, as well as Inuit hunters and fishermen...

  1. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    DEFF Research Database (Denmark)

    Shin, K. W.; Andersen, Poul

    2015-01-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached...

  2. Understanding and Mitigating Vortex-Dominated, Tip-Leakage and End-Wall Losses in a Transonic Splittered Rotor Stage

    Science.gov (United States)

    2015-04-23

    CLASSIFICATION OF: The requirement for higher power-to-weight ratios in modern jet engines leads to a reduced number of stages at increased loading...Stage - Final Report Report Title The requirement for higher power-to-weight ratios in modern jet engines leads to a reduced number of stages at...Garth Hobson, PhD, Anthony Gannon, PhD, Scott Drayton, LCDR USN. DESIGN AND TEST OF A TRANSONIC AXIAL SPLITTERED ROTOR, ASME TURBO Expo 2015. 15

  3. Reducing leakage current in semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Bin; Matioli, Elison de Nazareth; Palacios, Tomas Apostol

    2018-03-06

    A semiconductor device includes a first region having a first semiconductor material and a second region having a second semiconductor material. The second region is formed over the first region. The semiconductor device also includes a current blocking structure formed in the first region between first and second terminals of the semiconductor device. The current blocking structure is configured to reduce current flow in the first region between the first and second terminals.

  4. Geomechanical effects on CO2 leakage through fault zones during large-scale underground injection

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, Antonio P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rutqvist, Jonny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cappa, Frédéric [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of Nice Sophia-Antipolis, Nice (France). Cote d' Azur Observatory. GeoAzur

    2013-12-01

    The importance of geomechanics—including the potential for faults to reactivate during large-scale geologic carbon sequestration operations—has recently become more widely recognized. However, notwithstanding the potential for triggering notable (felt) seismic events, the potential for buoyancy-driven CO2 to reach potable groundwater and the ground surface is actually more important from public safety and storage-efficiency perspectives. In this context, this paper extends the previous studies on the geomechanical modeling of fault responses during underground carbon dioxide injection, focusing on the short-term integrity of the sealing caprock, and hence on the potential for leakage of either brine or CO2 to reach the shallow groundwater aquifers during active injection. We consider stress/strain-dependent permeability and study the leakage through the fault zone as its permeability changes during a reactivation, also causing seismicity. We analyze several scenarios related to the volume of CO2 injected (and hence as a function of the overpressure), involving both minor and major faults, and analyze the profile risks of leakage for different stress/strain-permeability coupling functions. We conclude that whereas it is very difficult to predict how much fault permeability could change upon reactivation, this process can have a significant impact on the leakage rate. Moreover, our analysis shows that induced seismicity associated with fault reactivation may not necessarily open up a new flow path for leakage. Results show a poor correlation between magnitude and amount of fluid leakage, meaning that a single event is generally not enough to substantially change the permeability along the entire fault length. Finally, and consequently, even if some changes in permeability occur, this does not mean that the CO2 will migrate up along the entire fault, breaking through the caprock to enter the overlying aquifer.

  5. Twelve Tips for Effective Electronic Presentation.

    Science.gov (United States)

    Crosby, Joy

    1994-01-01

    Offers 12 tips for effective electronic presentation. This article is intended for readers who may be considering using electronic presentation for the first time. Offers reasons for its popularity and occasions when it may be used. The tips offer assistance in the design and presentation of electronic material. (LZ)

  6. Economics of tipping the climate dominoes

    Science.gov (United States)

    Lemoine, Derek; Traeger, Christian P.

    2016-05-01

    Greenhouse gas emissions can trigger irreversible regime shifts in the climate system, known as tipping points. Multiple tipping points affect each other’s probability of occurrence, potentially causing a `domino effect’. We analyse climate policy in the presence of a potential domino effect. We incorporate three different tipping points occurring at unknown thresholds into an integrated climate-economy model. The optimal emission policy considers all possible thresholds and the resulting interactions between tipping points, economic activity, and policy responses into the indefinite future. We quantify the cost of delaying optimal emission controls in the presence of uncertain tipping points and also the benefit of detecting when individual tipping points have been triggered. We show that the presence of these tipping points nearly doubles today’s optimal carbon tax and reduces peak warming along the optimal path by approximately 1 °C. The presence of these tipping points increases the cost of delaying optimal policy until mid-century by nearly 150%.

  7. Nanobits - exchangable and customisable scanning probe tips

    DEFF Research Database (Denmark)

    Yildiz, Izzet

    Invention of atomic force microscopy (AFM) pioneered a novel aspect for the surface metrology concept. A range of scanning probe methods have been developed over the years based on different sorts of tip-surface interaction: electrical, optical, thermal, force. Reproducible and fast fabrication...... miniaturisation requires the scanning probes to adapt into finer geometries to provide higher lateral resolution. To meet these needs critical dimension AFM (CD-AFM) and deep trench AFM (DT-AFM) were invented, which use different types of AFM tips: high-aspect-ratio tips for DT-AFM and CD tips for CD...... replacement could greatly increase the efficiency and adaptability of a CD system. In this PhD study, NanoBits – nano-sized customisable and exchangeable scanning probe tips – were developed to meet the demands of current AFM applications. Two different methods were followed for the fabrication of Nano...

  8. Monitoring Subsurface Fluid Flow Using Perfluorocarbon Tracers: Another Tool Potentially Available for Subsurface Fluid Flow Assessments

    Science.gov (United States)

    Perfluorocarbon Tracers (PFTs) Complement stable Isotopes and Geochemistry for Verifying, Assessing or Modeling Fluid Flow. Geochemistry, Isotopes and PFT’s complement Geophysics to monitor and verify plume movement, leakage to shallow aquifers or surface

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... they have increased pressure in the portal vein system. This pressure buildup can cause blood to flow ... the hepatic vein to identify the portal venous system. Access is then gained from the hepatic vein ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the portal vein system. This pressure buildup can cause blood to flow backward from the liver into ... in the wall of the stomach, which can cause severe bleeding. severe ascites (the accumulation of fluid ...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and devices that monitor your heart beat and blood pressure. top of page How does the procedure work? ... flow in the liver and reduces abnormally high blood pressure in the veins of the stomach, esophagus, bowel ...

  12. The tipping point: A mathematical model for the profit-driven abandonment of restaurant tipping

    Science.gov (United States)

    Clifton, Sara M.; Herbers, Eileen; Chen, Jack; Abrams, Daniel M.

    2018-02-01

    The custom of voluntarily tipping for services rendered has gone in and out of fashion in America since its introduction in the 19th century. Restaurant owners that ban tipping in their establishments often claim that social justice drives their decisions, but we show that rational profit-maximization may also justify the decisions. Here, we propose a conceptual model of restaurant competition for staff and customers, and we show that there exists a critical conventional tip rate at which restaurant owners should eliminate tipping to maximize profits. Because the conventional tip rate has been increasing steadily for the last several decades, our model suggests that restaurant owners may abandon tipping en masse when that critical tip rate is reached.

  13. Border adjustment for European emissions trading: Competitiveness and carbon leakage

    Energy Technology Data Exchange (ETDEWEB)

    Kuik, Onno, E-mail: onno.kuik@ivm.vu.n [Institute for Environmental Studies, VU University Amsterdam, De Boelelaan 1085, 1081 HV Amsterdam (Netherlands); Hofkes, Marjan [Institute for Environmental Studies, VU University Amsterdam, De Boelelaan 1085, 1081 HV Amsterdam (Netherlands)

    2010-04-15

    Unilateral or sub-global policies to combat climate change are potentially sensitive to free-riding and carbon leakage. One way of dealing with carbon leakage and competitiveness is the imposition of border adjustment measures for competing imports, for example in the form of the obligation to importers of goods to purchase and surrender emissions allowances to the authorities when importing. In this paper, we explore some implications of border adjustment measures in the EU ETS, for sectors that might be subject to carbon leakage. We examine the implications of two variants of these measures on the competitiveness of these sectors and on the global environment with the help of a multi-sector, multi-region computable general equilibrium (CGE) model of the global economy. Our calculations suggest that border adjustment might reduce the sectoral rate of leakage of the iron and steel industry rather forcefully, but that the reduction would be less for the mineral products sector, including cement. The reduction of the overall or macro rate of leakage would be modest. So, from an environmental point of view border tax adjustments would not be a very effective policy measure, but might mainly be justified by considerations of sectoral competitiveness.

  14. Border adjustment for European emissions trading. Competitiveness and carbon leakage

    Energy Technology Data Exchange (ETDEWEB)

    Kuik, Onno; Hofkes, Marjan [Institute for Environmental Studies, VU University Amsterdam, De Boelelaan 1085, 1081 HV Amsterdam (Netherlands)

    2010-04-15

    Unilateral or sub-global policies to combat climate change are potentially sensitive to free-riding and carbon leakage. One way of dealing with carbon leakage and competitiveness is the imposition of border adjustment measures for competing imports, for example in the form of the obligation to importers of goods to purchase and surrender emissions allowances to the authorities when importing. In this paper, we explore some implications of border adjustment measures in the EU ETS, for sectors that might be subject to carbon leakage. We examine the implications of two variants of these measures on the competitiveness of these sectors and on the global environment with the help of a multi-sector, multi-region computable general equilibrium (CGE) model of the global economy. Our calculations suggest that border adjustment might reduce the sectoral rate of leakage of the iron and steel industry rather forcefully, but that the reduction would be less for the mineral products sector, including cement. The reduction of the overall or macro rate of leakage would be modest. So, from an environmental point of view border tax adjustments would not be a very effective policy measure, but might mainly be justified by considerations of sectoral competitiveness. (author)

  15. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS AND METH....... On this basis it was decided to discontinue the study prematurely for ethical reasons. CONCLUSION: Decompression of the anastomosis with a transanal stent does not reduce the risk of anastomotic leakage after anterior resection.......OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... AND METHODS: Randomized open trial of 194 patients operated in 11 hospitals during September 2000 to September 2003 with anterior resection for a mobile rectal tumour, 115 men and 79 women, median age 68 years (range 37-90 years). The surgeon decided upon the use of a protective ileostomy, and after...

  16. Report on the water leakage from instrumentation pipe in JMTR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    On December 10, 2002, the leakage was found at the pressure instrumentation pipe attached to the exit pipe of No.1 charging pump of the purification system of a primary cooling system at JMTR in the Oarai Research establishment, JAERI. The Investigation Committee for Water Leakage from Instrumentation Pipe in JMTR was established and organized by specialists from inside and outside JAERI on December 16 and its meeting was held in public 3 times by 6th January, 2003. They found out the cause and countermeasures of cracks, and also investigated enhancement of safety management. As the result, it was considered that the leakage started around the 6th of December 2002 and the cause of the cracks was due to fatigue by vibration of the charging pump during operation. The committee discovered following incorrect actions in the safety management. First, operation of JMTR was continued without keeping careful watch in spite of occurrence of leakage detector alarm. Second, every time when the alarm range for the reasons other than the leakage, appropriate investigation and countermeasure were not taken. Third, the manager in charge didn't have a fair understanding of the situation and didn't give an appropriate direction. This is the report on the cause and countermeasures of cracks and enhancement of safety management. (author)

  17. Leakage magnetic field of BLDCM based on Comsol multiphysics

    Science.gov (United States)

    Zhang, Xiaojun; Wen, Jiabao; Wang, Wen; Sun, Jinghua

    2017-04-01

    The measurement of geomagnetic field conducted by underwater robot is widely used during cruise, however, it is often influenced by the strong electromagnetic interference of the other large-scale electronic equipment on the robot itself. The leakage magnetic field of high-power brushless DC motor (BLDCM) has been identified as one of the main interference source. To obtain accurate geomagnetic data, it is necessary to analyze the magnetic field characteristics of the leakage field of BLDCM. In this paper, we build a two-dimensional BLDCM model. In addition, we present the rotor's leakage magnetic field when the BLDCM is static, dynamic leakage magnetic field of the stator and rotor when BLDCM is working and the near-field characteristic of BLDCM's leakage magnetic field. Finally, this paper studies the relationship between the frequency of the magnetic field change and the speed of the BLDCM, which can be used to eliminate the AC interference magnetic field. Therefore the measuring accuracy of the geomagnetic field can be improved.

  18. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  19. FIELD EVALUATION OF IMPROVED METHODS FOR MEASURING THE AIR LEAKAGE OF DUCT SYSTEMS UNDER NORMAL OPERATING CONDITIONS IN 51 HOMES

    Energy Technology Data Exchange (ETDEWEB)

    Paul W. Francisco; Larry Palmiter; Erin Kruse; Bob Davis

    2003-10-18

    Duct leakage in forced-air distribution systems has been recognized for years as a major source of energy losses in residential buildings. Unfortunately, the distribution of leakage across homes is far from uniform, and measuring duct leakage under normal operating conditions has proven to be difficult. Recently, two new methods for estimating duct leakage at normal operating conditions have been devised. These are called the nulling test and the Delta-Q test. Small exploratory studies have been done to evaluate these tests, but previously no large-scale study on a broad variety of homes has been performed to determine the accuracy of these new methods in the field against an independent benchmark of leakage. This sort of study is important because it is difficult in a laboratory setting to replicate the range of leakage types found in real homes. This report presents the results of a study on 51 homes to evaluate these new methods relative to an independent benchmark and a method that is currently used. An evaluation of the benchmark procedure found that it worked very well for supply-side leakage measurements, but not as well on the return side. The nulling test was found to perform well, as long as wind effects were minimal. Unfortunately, the time and difficulty of setup can be prohibitive, and it is likely that this method will not be practical for general use by contractors except in homes with no return ducts. The Delta-Q test was found to have a bias resulting in overprediction of the leakage, which qualitatively confirms the results of previous laboratory, simulation, and small-scale field studies. On average the bias was only a few percent of the air handler flow, but in about 20% of the homes the bias was large. A primary flaw with the Delta-Q test is the assumption that the pressure between the ducts and the house remain constant during the test, as this assumption does not hold true. Various modifications to the Delta-Q method were evaluated as

  20. Using provenance of terrigenous sediment to reconstruct the Agulhas Leakage during the Early and Late Pleistocene

    Science.gov (United States)

    Pearson, B.; Franzese, A. M.

    2017-12-01

    The Agulhas Current, the strongest western boundary current in the southern hemisphere, is uniquely characterized by its strong retroflection. The current carries water southward from the Indian Ocean toward the cape of South Africa, before turning back on itself. At this point of retroflection, some of the current's flow escapes into the southern Atlantic Ocean. This transfer of water from the Indian Ocean to Atlantic Ocean makes up the Agulhas Leakage. The Leakage occurs in a series of eddies and rings located in the Cape Basin south of the African continent. Scientific literature demonstrates that relatively buoyant leakage water has been a determining factor varying strength of the Atlantic Meridional Ocean Current (AMOC), during glacial-interglacial cycles. It has been demonstrated that radiogenic isotope, major, and trace element concentrations serve as a proxy for terrigenous sediment provenance in the Agulhas region. Current understanding is that terrigenous sediment provenance is older during warmer periods of deposition. This corresponds to more input from southeastern African end members, and thus a stronger Agulhas Current, during warming periods in the paleoclimate record. Conversely, younger terrigenous sediment deposited during colder periods, such as the Last Glacial Maximum, suggests a weaker Agulhas Current, and less Agulhas Leakage. In 2016, on the International Ocean Discovery Program Expedition 361, sediment cores were drilled at 6 sites in the Greater Agulhas region. A major goal of the expedition was to expand knowledge of the relation between changes in the Agulhas System and changes in paleoclimate, southern African climate, and AMOC. We analyzed sediment from Expedition 361 Site U1479 (35°03.53'S; 17°24.06'E; 2615 mbsl) located where the Agulhas Leakage occurs. We measured Argon, strontium isotope ratios, ɛNd, trace and major element concentrations on the <2 micron clay fraction. Preliminary results foretell promising findings. For

  1. Magnetotelluric Detection Thresholds as a Function of Leakage Plume Depth, TDS and Volume

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Buscheck, T. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mansoor, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Carroll, S. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-21

    We conducted a synthetic magnetotelluric (MT) data analysis to establish a set of specific thresholds of plume depth, TDS concentration and volume for detection of brine and CO2 leakage from legacy wells into shallow aquifers in support of Strategic Monitoring Subtask 4.1 of the US DOE National Risk Assessment Partnership (NRAP Phase II), which is to develop geophysical forward modeling tools. 900 synthetic MT data sets span 9 plume depths, 10 TDS concentrations and 10 plume volumes. The monitoring protocol consisted of 10 MT stations in a 2×5 grid laid out along the flow direction. We model the MT response in the audio frequency range of 1 Hz to 10 kHz with a 50 Ωm baseline resistivity and the maximum depth up to 2000 m. Scatter plots show the MT detection thresholds for a trio of plume depth, TDS concentration and volume. Plumes with a large volume and high TDS located at a shallow depth produce a strong MT signal. We demonstrate that the MT method with surface based sensors can detect a brine and CO2 plume so long as the plume depth, TDS concentration and volume are above the thresholds. However, it is unlikely to detect a plume at a depth larger than 1000 m with the change of TDS concentration smaller than 10%. Simulated aquifer impact data based on the Kimberlina site provides a more realistic view of the leakage plume distribution than rectangular synthetic plumes in this sensitivity study, and it will be used to estimate MT responses over simulated brine and CO2 plumes and to evaluate the leakage detectability. Integration of the simulated aquifer impact data and the MT method into the NRAP DREAM tool may provide an optimized MT survey configuration for MT data collection. This study presents a viable approach for sensitivity study of geophysical monitoring methods for leakage detection. The results come in handy for rapid assessment of leakage detectability.

  2. Rotor aerodynamic power limits at low tip speed ratio using CFD

    International Nuclear Information System (INIS)

    Mikkelsen, Robert F; Sarmast, Sasan; Henningson, Dan; Sørensen, Jens N

    2014-01-01

    When investigating limits of rotor aerodynamic models, the Betz limit serves as a solid marker of an upper limit which no model should be able to exceed. A century ago Joukowsky (1912) proposed a rotor aerodynamic model utilizing a rotating actuator disc with a constant circulation. This model has since then been the subject of much controversy as it predicts a power performance that for all tip speed ratios exceeds the Betz limit and which goes to infinity when the tip speed ratio goes to zero. Recently, it was demonstrated that the Joukowsky model is fully consistent with the inviscid Euler equations and that the apparent inconsistency partly can be explained by the lack of viscous effects (Sprensen and van Kuik [4]). However, even including a term to account for the effect of viscosity at small tip speed ratios, the model still predicts a power yield that exceeds the Betz limit. In the present work we study in detail, using a CFD actuator line model, the flow behavior for rotors at small tip speed ratios. It is shown that the excessive swirl appearing towards the rotor center at small tip speed ratios generates vortex breakdown, causing a recirculating zone in the wake that limits the power yield of the rotor. The appearance of vortex breakdown has a similar effect on the flow behavior as the vortex ring state that usually appears at higher tip speed ratios. Limits to where vortex breakdown might occur with tip speed ratio and rotor loading as parameter are investigated and presented in the paper. The limits found correspond to well-known criterion for vortex breakdown onset for swirling flows in general. By applying a criterion for vortex breakdown in combination with the general momentum theory, the power performance always stays below the Betz limit

  3. Lateral flow strip assay

    Science.gov (United States)

    Miles, Robin R [Danville, CA; Benett, William J [Livermore, CA; Coleman, Matthew A [Oakland, CA; Pearson, Francesca S [Livermore, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2011-03-08

    A lateral flow strip assay apparatus comprising a housing; a lateral flow strip in the housing, the lateral flow strip having a receiving portion; a sample collection unit; and a reagent reservoir. Saliva and/or buccal cells are collected from an individual using the sample collection unit. The sample collection unit is immersed in the reagent reservoir. The tip of the lateral flow strip is immersed in the reservoir and the reagent/sample mixture wicks up into the lateral flow strip to perform the assay.

  4. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  5. On the Connection between Leakage Tolerance and Adaptive Security

    DEFF Research Database (Denmark)

    Nielsen, Jesper Buus; Venturi, Daniele; Zottarel, Angela

    2013-01-01

    We revisit the context of leakage-tolerant interactive protocols as defined by Bitanski, Canetti and Halevi (TCC 2012). Our contributions can be summarized as follows: For the purpose of secure message transmission, any encryption protocol with message space M and secret key space SK tolerating...... at the end of the protocol execution, if and only if the protocol has passive adaptive security against an adaptive corruption of one party at the end of the protocol execution. This shows that as soon as a little leakage is tolerated, one needs full adaptive security. In case more than one party can...... be corrupted, we get that leakage tolerance is equivalent to a weaker form of adaptivity, which we call semi-adaptivity. Roughly, a protocol has semi-adaptive security if there exist a simulator which can simulate the internal state of corrupted parties, however, such a state is not required...

  6. Low dark leakage current in organic planar heterojunction photodiodes

    Science.gov (United States)

    Shekhar, Himanshu; Solomeshch, Olga; Liraz, Dan; Tessler, Nir

    2017-11-01

    It is often suggested that the dark leakage current of organic photodiodes is due to extrinsic leakage paths that do not involve the electronic junction. By studying a series of devices, where the acceptor is kept constant (C70) and the donor material is varied, we find a direct correlation between the strength of the sub-gap signature of the charge-transfer states and the leakage current. Attributing the differences in the sub-gap absorption to the donor's sub-gap states suggests that the donor's side of the junction should be made longer, to push the Fermi level at V = 0 towards the acceptor's LUMO, and thus, an optimized value of 800 Pacm-2 at V = -1 V is reported.

  7. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  8. The bacterial fimbrial tip acts as a mechanical force sensor.

    Directory of Open Access Journals (Sweden)

    Pavel Aprikian

    2011-05-01

    Full Text Available There is increasing evidence that the catch bond mechanism, where binding becomes stronger under tensile force, is a common property among non-covalent interactions between biological molecules that are exposed to mechanical force in vivo. Here, by using the multi-protein tip complex of the mannose-binding type 1 fimbriae of Escherichia coli, we show how the entire quaternary structure of the adhesive organella is adapted to facilitate binding under mechanically dynamic conditions induced by flow. The fimbrial tip mediates shear-dependent adhesion of bacteria to uroepithelial cells and demonstrates force-enhanced interaction with mannose in single molecule force spectroscopy experiments. The mannose-binding, lectin domain of the apex-positioned adhesive protein FimH is docked to the anchoring pilin domain in a distinct hooked manner. The hooked conformation is highly stable in molecular dynamics simulations under no force conditions but permits an easy separation of the domains upon application of an external tensile force, allowing the lectin domain to switch from a low- to a high-affinity state. The conformation between the FimH pilin domain and the following FimG subunit of the tip is open and stable even when tensile force is applied, providing an extended lever arm for the hook unhinging under shear. Finally, the conformation between FimG and FimF subunits is highly flexible even in the absence of tensile force, conferring to the FimH adhesin an exploratory function and high binding rates. The fimbrial tip of type 1 Escherichia coli is optimized to have a dual functionality: flexible exploration and force sensing. Comparison to other structures suggests that this property is common in unrelated bacterial and eukaryotic adhesive complexes that must function in dynamic conditions.

  9. On camera-based smoke and gas leakage detection

    Energy Technology Data Exchange (ETDEWEB)

    Nyboe, Hans Olav

    1999-07-01

    Gas detectors are found in almost every part of industry and in many homes as well. An offshore oil or gas platform may host several hundred gas detectors. The ability of the common point and open path gas detectors to detect leakages depends on their location relative to the location of a gas cloud. This thesis describes the development of a passive volume gas detector, that is, one than will detect a leakage anywhere in the area monitored. After the consideration of several detection techniques it was decided to use an ordinary monochrome camera as sensor. Because a gas leakage may perturb the index of refraction, parts of the background appear to be displaced from their true positions, and it is necessary to develop algorithms that can deal with small differences between images. The thesis develops two such algorithms. Many image regions can be defined and several feature values can be computed for each region. The value of the features depends on the pattern in the image regions. The classes studied in this work are: reference, gas, smoke and human activity. Test show that observation belonging to these classes can be classified fairly high accuracy. The features in the feature set were chosen and developed for this particular application. Basically, the features measure the magnitude of pixel differences, size of detected phenomena and image distortion. Interesting results from many experiments are presented. Most important, the experiments show that apparent motion caused by a gas leakage or heat convection can be detected by means of a monochrome camera. Small leakages of methane can be detected at a range of about four metres. Other gases, such as butane, where the densities differ more from the density of air than the density of methane does, can be detected further from the camera. Gas leakages large enough to cause condensation have been detected at a camera distance of 20 metres. 59 refs., 42 figs., 13 tabs.

  10. Crack Tip Mechanics in Distortion Gradient Plasticity

    DEFF Research Database (Denmark)

    Fuentes-Alonso, Sandra; Martínez Pañeda, Emilio

    2017-01-01

    The important role of geometrically necessary dislocations in structural integrity assessment has encouraged an extensive use of strain gradient plasticity theories to characterize the behavior at the small scales involved in crack tip deformation. However, despite the popularity of Distortion...... Gradient Plasticity (DGP), the influence on crack tip mechanics of DGP's distinguishing features that entail superior modelling capabilities has not been investigated yet. In this work crack tip fields are thoroughly examined by implementing the higher order theory of DGP in an implicit finite element...

  11. System-Level Analysis Modeling of Impacts of Operation Schemes of Geologic Carbon Dioxide Storage on Deep Groundwater and Carbon Dioxide Leakage Risk

    Science.gov (United States)

    Park, S.; Lee, S.; Park, J.; Kim, J.; Kihm, J.

    2013-12-01

    The objectives of this study are to predict quantitatively groundwater and carbon dioxide flow in deep saline sandstone aquifers under various carbon dioxide injection schemes (injection rate, injection period) and to analyze integratively impacts of such carbon dioxide injection schemes on deep groundwater (brine) and carbon dioxide leakage risk through abandoned wells or faults. In order to achieve the first objective, a series of process-level prediction modeling of groundwater and carbon dioxide flow in a deep saline sandstone aquifer under several carbon dioxide injection schemes was performed using a multiphase thermo-hydrological numerical model TOUGH2 (Pruess et al., 1999). The prediction modeling results show that the extent of carbon dioxide plume is significantly affected by such carbon dioxide injection schemes. In order to achieve the second objective, a series of system-level analysis modeling of deep groundwater and carbon dioxide leakage risk through an abandoned well or a fault under several carbon dioxide injection schemes was then performed using a brine and carbon dioxide leakage risk analysis model CO2-LEAK (Kim, 2012). The analysis modeling results show that the rates and amounts of deep groundwater and carbon dioxide leakage through an abandoned well or a fault increase as the carbon dioxide injection rate increases. However, the rates and amounts of deep groundwater and carbon dioxide leakage through an abandoned well or a fault decrease as the carbon dioxide injection period increases. These system-level analysis modeling results for deep groundwater and carbon dioxide leakage risk can be utilized as baseline data for establishing guidelines to mitigate anticipated environmental adverse effects on shallower groundwater systems (aquifers) when deep groundwater and carbon dioxide leakage occur. This work was supported by the Geo-Advanced Innovative Action (GAIA) Program funded by the Korea Environmental Industry and Technology Institute

  12. New Leakage Current Particulate Matter Sensor for On-Board Diagnostics

    Directory of Open Access Journals (Sweden)

    Jiawei Wang

    2016-01-01

    Full Text Available Structure and principle of the new leakage current particulate matter (PM sensor are introduced and further study is performed on the PM sensor with the combination of numerical simulation and bench test. High voltage electrode, conductive shell, and heaters are all built-in. Based on the principle of Venturi tube and maze structure design, this sensor can detect transient PM concentrations. Internal flow field of the sensor and distribution condition of PM inside the sensor are analyzed through gas-solid two-phase flow numerical simulation. The experiment was also carried out on the whole sensor system (including mechanical and electronic circuit part and the output signals were analyzed. The results of simulation and experiment reveal the possibility of PM concentration (mass detection by the sensor.

  13. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...... with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  14. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Zhang, Jun; Ouyang, Ziwei; Duffy, Maeve C.

    2014-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...... with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  15. Investigation of Flyback Transformer Flux Leakage Reduction Ways

    Directory of Open Access Journals (Sweden)

    Edvardas Bielskis

    2017-07-01

    Full Text Available Results of experimental investigation and design optimization of flyback transformer are presented. Aim of the work is to investigate experimentally the impact of the flyback transformer design on the flux leakage and maximal output power. It is difficult to evaluate the effect of the leakage flux mathematically because it depends on various factors: the position of the windings relative to each other; the position of the windings in the transformer; the distance between the winding. A multi-winding flyback transformer was used for experiments. Using the results of the experiments optimal design of the investigated flyback transformer was defined.

  16. Airbag for the closing of pipelines on explosions and leakages

    DEFF Research Database (Denmark)

    Eisenreich, N.; Neutz, J.; Seiler, F.

    2007-01-01

    This paper is a result of international effort aimed at the construction of a device for quick closing of pipelines in the case of explosion propagation and/or chemical leakage. Such a problem exists in industries where flammable substances are transported by pipelines. The basic solution principle...... was the idea to use airbags similar to those utilized in cars. Two pipeline applications were taken into consideration: a low-pressure module able to suppress explosion propagation and a high-pressure module to stop leakages from, e.g. natural gas pipeline capable to be used for duct diameters up to 0.6 m...

  17. Miniature ball-tip optical fibers for use in thulium fiber laser ablation of kidney stones

    Science.gov (United States)

    Wilson, Christopher R.; Hardy, Luke A.; Kennedy, Joshua D.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-01-01

    Optical fibers, consisting of 240-μm-core trunk fibers with rounded, 450-μm-diameter ball tips, are currently used during Holmium:YAG laser lithotripsy to reduce mechanical damage to the inner lining of the ureteroscope working channel during fiber insertion and prolong ureteroscope lifetime. Similarly, this study tests a smaller, 100-μm-core fiber with 300-μm-diameter ball tip during thulium fiber laser (TFL) lithotripsy. TFL was operated at a wavelength of 1908 nm, with 35-mJ pulse energy, 500-μs pulse duration, and 300-Hz pulse rate. Calcium oxalate/phosphate stone samples were weighed, laser procedure times were measured, and ablation rates were calculated for ball tip fibers, with comparison to bare tip fibers. Photographs of ball tips were taken before and after each procedure to track ball tip degradation and determine number of procedures completed before need for replacement. A high speed camera also recorded the cavitation bubble dynamics during TFL lithotripsy. Additionally, saline irrigation rates and ureteroscope deflection were measured with and without the presence of TFL fiber. There was no statistical difference (P>0.05) between stone ablation rates for single-use ball tip fiber (1.3±0.4 mg/s) (n=10), multiple-use ball tip fiber (1.3±0.5 mg/s) (n=44), and conventional single-use bare tip fibers (1.3±0.2 mg/s) (n=10). Ball tip durability varied widely, but fibers averaged greater than four stone procedures before failure, defined by rapid decline in stone ablation rates. Mechanical damage at the front surface of the ball tip was the limiting factor in fiber lifetime. The small fiber diameter did not significantly impact ureteroscope deflection or saline flow rates. The miniature ball tip fiber may provide a cost-effective design for safe fiber insertion through the ureteroscope working channel and into the ureter without risk of instrument damage or tissue perforation, and without compromising stone ablation efficiency during TFL lithotripsy.

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... system. This pressure buildup can cause blood to flow backward from the liver into the veins of the spleen, stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding and the accumulation of fluid in the chest or abdomen. This condition is ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... blood flow in the liver and reduces abnormally high blood pressure in the veins of the stomach, esophagus, bowel ... the liver to bypass the liver entirely, reducing high blood pressure in the portal vein and the associated risk ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... increased pressure in the portal vein system. This pressure buildup can cause blood to flow backward from the liver into the veins of the spleen, stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding and the accumulation of fluid in the ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... flow in the liver and reduces abnormally high blood pressure in the veins of the stomach, esophagus, bowel and liver, reducing ... liver to bypass the liver entirely, reducing high blood pressure in the portal vein and the associated risk of bleeding from enlarged ...

  2. Long-term monitoring of marine gas leakage

    Science.gov (United States)

    Spickenbom, Kai; Faber, Eckhard; Poggenburg, Jürgen; Seeger, Christian; Furche, Markus

    2010-05-01

    The sequestration of CO2 in sub-seabed geological formations is one of the Carbon Capture and Storage (CCS) strategies currently under study. Although offshore operations are significantly more expensive than comparable onshore operations, the growing public resistance against onshore CCS projects makes sub-seabed storage a promising option. Even after a thorough review of the geological setting, there is always the possibility of leakage from the reservoir. As part of the EU-financed project CO2ReMoVe (Research, Monitoring, Verification), which aims to develop innovative research and technologies for monitoring and verification of carbon dioxide geological storage, we are working on the development of submarine long-term gas flow monitoring systems. The basic design of the monitoring system builds on our experience in volcano monitoring. Early prototypes were composed of a raft floating on the surface of a mud volcano, carrying sensors for CO2 flux and concentration, data storage and transmission, and power supply by battery-buffered solar panels. The system was modified for installation in open sea by using a buoy instead of a raft and a funnel on the seafloor to collect the gas, connected by a flexible tube. This setup provides a cost-effective solution for shallow waters. However, a buoy interferes with ship traffic, and it is also difficult to adapt this design to greater water depths. These requirements can best be complied by a completely submersed system. A system for unattended long-term monitoring in a marine environment has to be extremely durable. Therefore, we focussed on developing a mechanically and electrically as simple setup as possible, which has the additional advantage of low cost. The system consists of a funnel-shaped gas collector, a sensor head and pressure housings for electronics and power supply. Since this setup is inexpensive, it can be deployed in numbers to cover larger areas. By addition of multi-channel data loggers, data

  3. Smooth School Transitions: Tips for Military Families

    Science.gov (United States)

    ... Life Listen Text Size Email Print Share Smooth School Transitions: Tips for Military Families Page Content Article ... Internet is a great resource for this. District & School Web sites Parents and children can visit the ...

  4. Helping Your Child: Tips for Parents

    Science.gov (United States)

    ... inactive computer and video games, or listening to music on hand-held devices while sitting down. Tips ... habits or weight. Remember, you play the biggest role in your children's lives. You can help your ...

  5. Tips for Teens with Diabetes: About Diabetes

    Science.gov (United States)

    National Diabetes Education Program (NDEP), 2010

    2010-01-01

    Diabetes is a serious disease. It means that one's blood glucose, also called blood sugar, is too high. Having too much glucose in a person's blood is not healthy. This paper offers tips for managing diabetes.

  6. Winter Safety Tips for Older Adults

    Science.gov (United States)

    Winter Safety Tips for Older Adults Expert Information from Healthcare Professionals Who Specialize in the Care of ... thick clothing. Think about getting your thermals! –Essential winter wears: hats, gloves or preferably mittens, winter coat, ...

  7. Essential Outdoor Sun Safety Tips for Winter

    Science.gov (United States)

    ... Vitamin D Essential Outdoor Sun Safety Tips for Winter Winter sports enthusiasts are at increased risk for overexposure ... associated with sun exposure. "It's easy to associate winter with frostbite and windburn, but most people are ...

  8. Can't sleep? Try these tips

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000853.htm Can't sleep? Try these tips To use the sharing features ... time. But if it happens often, lack of sleep can affect your health and make it hard ...

  9. Sleep Tips: 7 Steps to Better Sleep

    Science.gov (United States)

    ... turn every night. Consider simple tips for better sleep, from setting a sleep schedule to including physical activity in your daily ... factors that can interfere with a good night's sleep — from work stress and family responsibilities to unexpected ...

  10. Impetigo: Tips for Treatment and Prevention

    Science.gov (United States)

    ... DO Videos Contact Close ‹ Back to Healthy Living Impetigo: Tips for Treatment and Prevention The symptoms of ... to other parts of their bodies. Causes of Impetigo Impetigo usually affects preschool and school-aged children, ...

  11. Next Stop Adulthood: Tips for Parents

    Science.gov (United States)

    ... Email Print Share Next Stop Adulthood: Tips For Parents Page Content Article Body Becoming a young adult is exciting, difficult, and scary for both parents and teens. It is a time of increasing ...

  12. 6 Tips: IBS and Complementary Health Practices

    Science.gov (United States)

    ... health practice for IBS, here are 6 tips: Hypnotherapy (hypnosis). This practice involves the power of suggestion by ... IBS. According to reviews of the scientific literature, hypnotherapy may be a helpful treatment for managing IBS ...

  13. Tips to Manage Anxiety and Stress

    Science.gov (United States)

    ... 2018 Conference Snapshot Tips to Manage Anxiety and Stress When you're feeling anxious or stressed, the ... Subscribe to ADAA Triumph: Free Monthly E-News Stress Relief Kits Feeling stressed? Get an ADAA stress ...

  14. Tip velocity tracking control for elastic manipulators

    Science.gov (United States)

    Sever, Manfred Dieter Martin

    A unique approach to tip velocity control of an elastic robotic manipulator is presented. This method has potential application in teleoperation control and in applications where the trajectory is generated in real-time. Control is effected by reducing the tip velocity tracking error between the desired tip velocity and the measured tip velocity. Thus, in teleoperation, the concept of dead reckoning is used, so that while the manipulator's desired tip velocity is specified, the goal is for the tip to follow a path, leading toward a desired terminal position. This is done by concentrating the controller's effort on the manipulator tip while allowing the manipulator's links to deform., The controller utilizes a gain scheduling scheme to arrive at an appropriate feedback law. The control algorithm is implemented using a parallel-processing scheme on a multiprocessor system which consists of INMOS TransputersRTM . Experimental results are obtained using Radius, the Space Robotics Laboratory Facility at the University of Toronto Institute for Aerospace Studies. Radius was designed to serve specifically as a test-bed for the development and evaluation of control methods for elastic manipulators. For the present work Radius is configured as a two-link manipulator with both links structurally flexible. One of the trajectories used for the simulations and experiment is a square, which is quite difficult for an elastic manipulator to execute. This box trajectory is more demanding than trajectories typically executed by Canadarm and so link elasticity becomes an important consideration. The effect of elasticity is demonstrated using an independent joint PD controller. In simulation, excellent tip velocity tracking was achieved using the proposed controller. In the experiment, reasonable accuracy in following the desired tip path was attained, however, disturbances, mainly a result of unmodeled joint dynamics, caused degraded performance. The controller may be improved by

  15. Full tip imaging in atom probe tomography

    Energy Technology Data Exchange (ETDEWEB)

    Du, Sichao [School of Physics, The University of Sydney, NSW 2006 (Australia); Burgess, Timothy [Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 0200 (Australia); Tjing Loi, Shyeh [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); Gault, Baptiste [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006 (Australia); Department of Materials Science and Engineering, McMaster University, 1280 Main St W, Hamilton, ON, Canada L8S 4L8 (Canada); Gao, Qiang [Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 0200 (Australia); Bao, Peite; Li, Li [School of Physics, The University of Sydney, NSW 2006 (Australia); Cui, Xiangyuan; Kong Yeoh, Wai [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); Hoe Tan, Hark; Jagadish, Chennupati [Department of Electronic Materials Engineering, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 0200 (Australia); Ringer, Simon P. [Australian Centre for Microscopy and Microanalysis, The University of Sydney, NSW 2006 (Australia); School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006 (Australia); Zheng, Rongkun, E-mail: rongkun.zheng@sydney.edu.au [School of Physics, The University of Sydney, NSW 2006 (Australia)

    2013-01-15

    Atom probe tomography (APT) is capable of simultaneously revealing the chemical identities and three dimensional positions of individual atoms within a needle-shaped specimen, but suffers from a limited field-of-view (FOV), i.e., only the core of the specimen is effectively detected. Therefore, the capacity to analyze the full tip is crucial and much desired in cases that the shell of the specimen is also the region of interest. In this paper, we demonstrate that, in the analysis of III-V nanowires epitaxially grown from a substrate, the presence of the flat substrate positioned only micrometers away from the analyzed tip apex alters the field distribution and ion trajectories, which provides extra image compression that allows for the analysis of the entire specimen. An array of experimental results, including field desorption maps, elemental distributions, and crystallographic features clearly demonstrate the fact that the whole tip has been imaged, which is confirmed by electrostatic simulations. -- Highlights: Black-Right-Pointing-Pointer The full tip has been imaged by atom probe tomography. Black-Right-Pointing-Pointer The conductive substrate close to specimen tip introduces extra image compression. Black-Right-Pointing-Pointer The apex of the tip is far from a hemispherical shape. Black-Right-Pointing-Pointer This work demonstrates a way to increase the FOV of APT.

  16. University student's education after Fukushima nuclear leakage crisis

    International Nuclear Information System (INIS)

    Dou Daying; Gu Jianzhong; Zheng Jianying

    2012-01-01

    Fukushima nuclear leakage crisis after 3.11 earthquake and tsunami, the horrible INES-7 accident warns the colleagues all over the world. Own much to the experts' reports on public media, INES classification, basic knowledge of nuclear reactor, nuclear safety and protection had been discussed and brain-stormed in detail. (authors)

  17. Signature Schemes Secure against Hard-to-Invert Leakage

    DEFF Research Database (Denmark)

    Faust, Sebastian; Hazay, Carmit; Nielsen, Jesper Buus

    2012-01-01

    In the auxiliary input model an adversary is allowed to see a computationally hard-to-invert function of the secret key. The auxiliary input model weakens the bounded leakage assumption commonly made in leakage resilient cryptography as the hard-to-invert function may information-theoretically re......In the auxiliary input model an adversary is allowed to see a computationally hard-to-invert function of the secret key. The auxiliary input model weakens the bounded leakage assumption commonly made in leakage resilient cryptography as the hard-to-invert function may information......-theoretically reveal the entire secret key. In this work, we propose the first constructions of digital signature schemes that are secure in the auxiliary input model. Our main contribution is a digital signature scheme that is secure against chosen message attacks when given an exponentially hard-to-invert function...... of the secret key. As a second contribution, we construct a signature scheme that achieves security for random messages assuming that the adversary is given a polynomial-time hard to invert function. Here, polynomial-hardness is required even when given the entire public-key – so called weak auxiliary input...

  18. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Science.gov (United States)

    2010-10-01

    ... following minimum requirements: (1) A leakage survey with leak detector equipment must be conducted in business districts, including tests of the atmosphere in gas, electric, telephone, sewer, and water system... survey with leak detector equipment must be conducted outside business districts as frequently as...

  19. Exploitation of Unintentional Information Leakage from Integrated Circuits

    Science.gov (United States)

    Cobb, William E.

    2011-01-01

    The information leakage of electronic devices, especially those used in cryptographic or other vital applications, represents a serious practical threat to secure systems. While physical implementation attacks have evolved rapidly over the last decade, relatively little work has been done to allow system designers to effectively counter the…

  20. Detection of tissue expander leakage by methylene blue instillation ...

    African Journals Online (AJOL)

    Background: Tissue expansion is an important and widely used technique of soft tissue reconstruction. Leakage of the expanders is one of the complications and it might at times be difficult to detect. Method and Conclusion: We used methylene blue stained saline for inflation of tissue expanders in 42 cases and found it to ...

  1. Incidence and management of biliary leakage after hepaticojejunostomy

    NARCIS (Netherlands)

    de Castro, Steve M. M.; Kuhlmann, Koert F. D.; Busch, Olivier R. C.; van Delden, Otto M.; Laméris, Johan S.; van Gulik, Thomas M.; Obertop, Hugo; Gouma, Dirk J.

    2005-01-01

    This study analyzes the change in the management of biliary leakage after hepaticojejunostomy. Between 1993 and 2003 all patients (n = 1033) were studied with a hepaticojejunostomv as part of a pancreatoduodenectomy (n = 486), proximal bile duct resection (without liver resection) (n = 35), and

  2. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    model, most of them are unfortunately rather inefficient and come without practical security evaluations nor implementation attempts. In this work, we take a further step towards closing the gap between theoretical leakage resilient cryptography and more practice-oriented research. In particular, we...

  3. Impact of the Indonesian throughflow on Agulhas leakage

    NARCIS (Netherlands)

    le Bars, D.L.B.|info:eu-repo/dai/nl/326165150; Dijkstra, H.A.|info:eu-repo/dai/nl/073504467; de Ruijter, W.P.M.|info:eu-repo/dai/nl/068476760

    2013-01-01

    Using ocean models of different complexity we show that opening the Indonesian Passage between the Pacific and the Indian Ocean increases the input of Indian Ocean water into the South Atlantic via the Agulhas leakage. In a strongly eddying global 5 ocean model this response results from an

  4. VISUAL INSPECTION OF WATER LEAKAGE FROM GROUND PENETRATING RADAR RADARGRAM

    Directory of Open Access Journals (Sweden)

    N. N. Halimshah

    2015-10-01

    Full Text Available Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  5. Anastomotic leakage after anterior resection for rectal cancer: risk factors

    DEFF Research Database (Denmark)

    Bertelsen, C A; Andreasen, A H; Jørgensen, Torben

    2010-01-01

    OBJECTIVE: The study aimed to identify risk factors for clinical anastomotic leakage (AL) after anterior resection for rectal cancer in a consecutive national cohort. METHOD: All patients with an initial first diagnosis of colorectal adenocarcinoma were prospectively registered in a national......, smoking and perioperative bleeding. Faecal diversion is advisable after total mesorectal excision of low rectal tumours in order to prevent AL....

  6. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  7. Interslice leakage artifact reduction technique for simultaneous multislice acquisitions.

    Science.gov (United States)

    Cauley, Stephen F; Polimeni, Jonathan R; Bhat, Himanshu; Wald, Lawrence L; Setsompop, Kawin

    2014-07-01

    Controlled aliasing techniques for simultaneously acquired echo-planar imaging slices have been shown to significantly increase the temporal efficiency for both diffusion-weighted imaging and functional magnetic resonance imaging studies. The "slice-GRAPPA" (SG) method has been widely used to reconstruct such data. We investigate robust optimization techniques for SG to ensure image reconstruction accuracy through a reduction of leakage artifacts. Split SG is proposed as an alternative kernel optimization method. The performance of Split SG is compared to standard SG using data collected on a spherical phantom and in vivo on two subjects at 3 T. Slice-accelerated and nonaccelerated data were collected for a spin-echo diffusion-weighted acquisition. Signal leakage metrics and time-series SNR were used to quantify the performance of the kernel fitting approaches. The Split SG optimization strategy significantly reduces leakage artifacts for both phantom and in vivo acquisitions. In addition, a significant boost in time-series SNR for in vivo diffusion-weighted acquisitions with in-plane 2× and slice 3× accelerations was observed with the Split SG approach. By minimizing the influence of leakage artifacts during the training of SG kernels, we have significantly improved reconstruction accuracy. Our robust kernel fitting strategy should enable better reconstruction accuracy and higher slice-acceleration across many applications. Copyright © 2013 Wiley Periodicals, Inc.

  8. Reaction-driven casing expansion : potential for wellbore leakage mitigation

    NARCIS (Netherlands)

    Wolterbeek, Timotheus K. T.|info:eu-repo/dai/nl/357401387; van Noort, Reinier|info:eu-repo/dai/nl/304833460; Spiers, Christopher J.|info:eu-repo/dai/nl/304829323

    It is generally challenging to predict the post-abandonment behaviour and integrity of wellbores. Leakage is, moreover, difficult to mitigate, particularly between the steel casing and outer cement sheath. Radially expanding the casing with some form of internal plug, thereby closing annular voids

  9. Benchmarking leakage from water reticulation systems in South Africa

    African Journals Online (AJOL)

    driniev

    5 (Special edition). 25. Available on website http://www.wrc.org.za. Benchmarking leakage from water reticulation systems in. South Africa. Caryn Seago1*, Jay Bhagwan2 and Ronnie McKenzie1. 1WRP Consulting ... limited and that careful management should be applied when ..... purchase price (or product price) of water.

  10. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  11. Incidence and management of bile leakage after partial liver resection

    NARCIS (Netherlands)

    Erdogan, D.; Busch, O. R. C.; van Delden, O. M.; Rauws, E. A. J.; Gouma, D. J.; van Gulik, T. M.

    2008-01-01

    Background/Aims: Bile leakage after partial liver resection still is a common complication and is associated with substantial morbidity and even mortality. Methods: A total of 234 consecutive liver resections without biliary reconstruction, performed between January 1992 and December 2004, were

  12. Carbon Leakage Revisited : Unilateral Climate Policy with Directed Technical Change

    NARCIS (Netherlands)

    Di Maria, C.; van der Werf, E.H.

    2005-01-01

    The increase in carbondioxide emissions by some countries in reaction to an emission reduction by countries with climate policy (carbon leakage) is seen as a serious threat to unilateral climate policy.Using a two-country model where only one of the countries enforces an exogenous cap on emissions,

  13. Benchmarking leakage from water reticulation systems in South Africa

    African Journals Online (AJOL)

    A project to assess the levels of leakage in 30 water utilities throughout South Africa was initiated by the Water Research Commission. The BENCHLEAK software was used to evaluate the water utilities and performance indicators calculated by the model were used to compare levels of non-revenue water. Results showed ...

  14. Leakage Currents and Gas Generation in Advanced Wet Tantalum Capacitors

    Science.gov (United States)

    Teverovsky, Alexander

    2015-01-01

    Currently, military grade, established reliability wet tantalum capacitors are among the most reliable parts used for space applications. This has been achieved over the years by extensive testing and improvements in design and materials. However, a rapid insertion of new types of advanced, high volumetric efficiency capacitors in space systems without proper testing and analysis of degradation mechanisms might increase risks of failures. The specifics of leakage currents in wet electrolytic capacitors is that the conduction process is associated with electrolysis of electrolyte and gas generation resulting in building up of internal gas pressure in the parts. The risk associated with excessive leakage currents and increased pressure is greater for high value advanced wet tantalum capacitors, but it has not been properly evaluated yet. In this work, in Part I, leakages currents in various types of tantalum capacitors have been analyzed in a wide range of voltages, temperatures, and time under bias. Gas generation and the level of internal pressure have been calculated in Part II for different case sizes and different hermeticity leak rates to assess maximal allowable leakage currents. Effects related to electrolyte penetration to the glass seal area have been studied and the possibility of failures analyzed in Part III. Recommendations for screening and qualification to reduce risks of failures have been suggested.

  15. Effect of Surface Treatments on Leakage of Zirconium Oxide Ceramics

    Directory of Open Access Journals (Sweden)

    Göknil Alkan Demetoğlu

    2016-08-01

    Full Text Available Objective: The aim of this pilot study was to compare the effects of pretreatments on leakage of zirconia ceramics. Materials and Methods: The speciments divided into 6 groups that were subsequently treated as follows: group 1, no treatment (control; group 2, the ceramic surfaces were airborne-particle abraded with 110 μm aluminum-oxide (Al2O3 particles; group 3, after abrasion of the surfaces with 110 μm Al2O3 particles, silica coating using 30 μm (Al2O3 particles modified by silica (rocatec system and application of the silane coupling agent (espe-sil; group 4, ceramic surfaces irritated with neodymium-doped yttrium aluminium garnet (Nd:YAG laser [fidelis plus 3 foton (Ljubljana, Slovenia] at 20 hz, 100 mj, 2 w, 100 μs; group 5, ceramic surfaces irritated with Nd:YAG laser at fidelis plus 3 fotona (Ljubljana, Slovenia at 20 hz, 100 mj, 2 w, 100 μs; group 6; application of a zirconia primer (z-prime plus bisco, IL, USA agent. And all ceramics tested for leakage. Results: For marginal leakage, score 0 was found in all groups. Conclusion: No significant differences were found in marginal leakage under all conditions.

  16. A Numerical Study of Gas Injection and Caprock Leakage from Yort-e-Shah Aquifer in Iran

    Directory of Open Access Journals (Sweden)

    H. S. Rad

    2017-08-01

    Full Text Available In order to mitigate the adverse effects of global warming due to anthropogenic CO2 emission into the atmosphere, geological sequestration of CO2 into subsurface formations has been investigated by many studies over the last decade. However, selection of formations and sites for any field application is still open to debate. The most important properties of a formation suitable for carbon sequestration are those which impact the fluid flow processes. The injection or extraction of gas can change the pore pressure within the reservoir, which in turn results in redistribution of the stress field. These events may cause considerably leakage of the fluid into the surrounding geological formations or ground surface. The main objective of this paper is to evaluate the potential of Yort-e-Shah aquifer for CO2 storage, through a series of analyses with a simplified numerical model. The numerical results suggest that the optimum injection pressure in Yort-e-Shah aquifer is about 15.51 MPa with a safety factor of about 1.7. The results of the fluid pressure and gas plume expansion are presented. Also, an analysis was carried out for a case with leak through cap rock. When there is no leak, the pressure within the aquifer is stable, while on the other hand, the pressure in case of leakage is slightly smaller. In case of leakage, the pressure is lowest in the middle of the reservoir, mainly because the nodes at the middle of the aquifer are influenced by all the leakage points, while around the wellbore or near the end of gas plume, are affected less due to their longer distance to leakage points.

  17. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  18. Understanding and managing leakage in forest-based greenhouse-gas-mitigation projects.

    Science.gov (United States)

    Schwarze, Reimund; Niles, John O; Olander, Jacob

    2002-08-15

    A major concern about land use, land-use change and forestry (LULUCF) projects under the Clean Development Mechanism (CDM) is the potential for leakage. Leakage refers to a net increase of greenhouse-gas emissions in an area outside the project resulting from the CDM activity. This paper provides an overview of leakage, its definitions and its causes. It describes ways that LULUCF projects may suffer from leakage and attempts to assess the magnitude of leakage risks for different LULUCF project types. It also summarizes some of the approaches, both in terms of policies and project development, to address LULUCF leakage.

  19. Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid

    DEFF Research Database (Denmark)

    Ma, Lin; Tang, F.; Zhou, F.

    2009-01-01

    the PV array and the ground. It is quite harmful to the body safety and PV system. In order to avoid leakage current, different inverter topologies that generate no varying common-mode voltages, such as bipolar pulse-width modulation (PWM) full-bridge topology, NPC topology have been proposed. From...... the safety and energy saving viewpoint, it is necessary to develop a higher efficiency topology. In this paper, the generation mechanism of common mode current is discussed. Then different methods used to eliminate the leakage current are compared. Finally, the full-bridge which generates no varying common......Due to the large surface of the PV generator, its stray capacity with respect to the ground reaches values that can be quite high. When no transformer is used in a grid-connected PV system, common-mode current, which caused by the common mode voltage, can flow through the stray capacitance between...

  20. Transjugular intrahepatic portosystemic shunt (TIPS) versus laparoscopic splenectomy (LS) plus preoperative endoscopic varices ligation (EVL) in the treatment of recurrent variceal bleeding.

    Science.gov (United States)

    Zhou, Jin; Wu, Zhong; Wu, Junchao; Wang, Xin; Li, Yongbin; Wang, Mingjun; Yang, Zhengguo; Peng, Bing; Zhou, Zongguang

    2013-08-01

    The aim of the present study was to compare elective transjugular intrahepatic portosystemic shunt (TIPS) and laparoscopic splenectomy (LS) plus preoperative endoscopic varices ligation (EVL) in their efficacy in preventing recurrent bleeding and improving the long-term liver function in patients with liver cirrhosis and portal hypertension. Between January 2009 and March 2012, we enrolled 83 patients (55 with TIPS, defined as the TIPS group, and 28 with LS plus preoperative EVL, defined as the LS group) with portal hypertension and a history of gastroesophageal variceal bleeding resulting from liver cirrhosis. The clinical characteristics, perioperative outcomes, and follow-up were recorded. No significant differences were observed between the two treatment groups with respect to the patients' characteristics and preoperative variables. Within 30 days after surgery, one patient in the TIPS group died of multiple organ dysfunction syndrome, whereas no patient in the LS group died. Complications occurred in 14 patients in the TIPS group, which included rebleeding, encephalopathy, ascites, bleeding from a pseudoaneurysm of the thoracoabdominal aorta, and pulmonary infection, compared with 5 patients in the LS group, which included pulmonary effusion, pancreatic leakage, and portal vein thrombosis. During a mean follow-up of 13.6 months in the TIPS group and 12.3 months in the LS group, the actuarial survival was 85.5 % in the TIPS group versus 100 % in the LS group. The long-term complications included rebleeding and encephalopathy in the TIPS group. LS plus EVL was superior to TIPS in the prevention of gastroesophageal variceal rebleeding in cirrhotic patients. This treatment was associated with a low rate of portosystemic encephalopathy and improvements in the long-term liver function.

  1. Integration of geotechnical and geophysical techniques for the characterization of a small earth-filled canal dyke and the localization of water leakage

    Science.gov (United States)

    Bièvre, Grégory; Lacroix, Pascal; Oxarango, Laurent; Goutaland, David; Monnot, Guy; Fargier, Yannick

    2017-04-01

    This paper investigates the combined use of extensive geotechnical, hydrogeological and geophysical techniques to assess a small earth dyke with a permanent hydraulic head, namely a canal embankment. The experimental site was chosen because of known issues regarding internal erosion and piping phenomena. Two leakages were visually located following the emptying of the canal prior to remediation works. The results showed a good agreement between the geophysical imaging techniques (Electrical Resistivity Tomography, P- and SH-waves Tomography) and the geotechnical data to detect the depth to the bedrock and its lateral variations. It appeared that surface waves might not be fully adapted for dyke investigation because of the particular geometry of the studied dyke, non-respectful of the 1D assumption, and which induced depth and velocity discrepancies retrieved from Rayleigh and Love waves inversion. The use of these classical prospecting techniques however did not allow to directly locate the two leakages within the studied earth dyke. The analysis of ambient vibration time series with a modified beam-forming algorithm allowed to localize the most energetic water flow prior to remediation works. It was not possible to detect the leakage after remediation works, suggesting that they efficiently contributed to significantly reduce the water flow. The second leakage was not detected probably because of a non-turbulent water flow, generating few energetic vibrations.

  2. Radiation leakage dose from Elekta electron collimation system.

    Science.gov (United States)

    Pitcher, Garrett M; Hogstrom, Kenneth R; Carver, Robert L

    2016-09-08

    This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were measured and calculated for two primary purposes: 1) to evaluate and document the out-of-field leakage dose in the patient plane and 2) to validate the dose distributions calculated using a BEAMnrc Monte Carlo (MC) model for out-of-field dose profiles. Off-axis dose profiles were measured in a water phantom at 100 cm SSD for 1 and 2 cm depths along the in-plane, cross-plane, and both diagonal axes using a cylindrical ionization chamber with the 10 × 10 and 20 × 20 cm2 applicators and 7, 13, and 20 MeV beams. Dose distributions were calculated using a previously developed BEAMnrc MC model of the Elekta Infinity accelerator for the same beam energies and applicator sizes and compared with measurements. Measured results showed that the in-field beam flatness met our acceptance criteria (± 3% on major and ±4% on diagonal axes) and that out-of-field mean and maximum percent leakage doses in the patient plane met acceptance criteria as specified by the International Electrotechnical Commission (IEC). Cross-plane out-of-field dose profiles showed greater leakage dose than in-plane profiles, attributed to the curved edges of the upper X-ray jaws and multileaf collimator. Mean leakage doses increased with beam energy, being 0.93% and 0.85% of maximum central axis dose for the 10 × 10 and 20 × 20 cm2 applicators, respectively, at 20 MeV. MC calculations predicted the measured dose to within 0.1% in most profiles outside the radiation field; however, excluding model-ing of nontrimmer applicator components led to calculations exceeding measured data by as much as 0.2% for some regions

  3. Tip clearance effects on loads and performances of semi-open impeller centrifugal pumps at different specific speeds

    Science.gov (United States)

    Boitel, G.; Fedala, D.; Myon, N.

    2016-11-01

    Relevant industrial standards or customer's specifications could strictly forbid any device adjusting the axial rotor/stator position, so that tip clearance between semi-open impeller and casing might become a result of the pump machining tolerances and assembling process, leading to big tip clearance variations compared to its nominal value. Consequently, large disparities of global performances (head, power, efficiency) and axial loads are observed with high risk of both specifications noncompliance and bearing damages. This work aims at quantifying these variations by taking into account tip clearance value and pump specific speed. Computational Fluid Dynamics is used to investigate this phenomenon by means of steady simulations led on a semi-open centrifugal pump numerical model including secondary flows, based on a k-omega SST turbulence model. Four different specific speed pump sizes are simulated (from 8 to 50, SI units), with three tip clearances for each size on a wide flow range (from 40% to 120% of the best efficiency point). The numerical results clearly show that head, power and efficiency increase as the tip clearance decreases for the whole flow range. This effect is more significant when the specific speed is low. Meanwhile, the resulting axial thrust on the impeller is very sensitive to the tip clearance and can even lead to direction inversion.

  4. The effect of varying levels of induced duct leakage on differential pressures in a Florida house

    International Nuclear Information System (INIS)

    Kozik, A.C.; Oppenheim, P.; Hintenlang, D.

    1995-01-01

    The objective of this research is to quantify the effect of varying levels of induced duct leakage on differential pressures and subsequent radon levels in a typical Florida residence. The heating and air conditioning (HAC) system of a residence was modified with the addition of a fresh air ventilation system. This modification provided the ability to simulate either a return leak or a supply leak in the HAC system. The amount of leakage induced can be varied using flow control dampers and an auxiliary fan located in the ventilation system ductwork. The house was pressurized and depressurized by adding 0.06 m 3 /s of ventilation air into the return side and removing 0.05 m 3 /s of ventilation air from the supply side of the air handling system, respectively. The subsequent changes in house pressure and ventilation rates reduced the indoor radon concentrations from 1,865 Bq/m 3 to 170 Bq/m 3 under pressurized conditions and to 305 Bq/m 3 under depressurized conditions

  5. Coronal heating in coupled photosphere-chromosphere-coronal systems: turbulence and leakage

    Science.gov (United States)

    Verdini, A.; Grappin, R.; Velli, M.

    2012-02-01

    Context. Coronal loops act as resonant cavities for low-frequency fluctuations that are transmitted from the deeper layers of the solar atmosphere. These fluctuations are amplified in the corona and lead to the development of turbulence that in turn is able to dissipate the accumulated energy, thus heating the corona. However, trapping is not perfect, because some energy leaks down to the chromosphere on a long timescale, limiting the turbulent heating. Aims: We consider the combined effects of turbulence and energy leakage from the corona to the photosphere in determining the turbulent energy level and associated heating rate in models of coronal loops, which include the chromosphere and transition region. Methods: We use a piece-wise constant model for the Alfvén speed in loops and a reduced MHD-shell model to describe the interplay between turbulent dynamics in the direction perpendicular to the mean field and propagation along the field. Turbulence is sustained by incoming fluctuations that are equivalent, in the line-tied case, to forcing by the photospheric shear flows. While varying the turbulence strength, we systematically compare the average coronal energy level and dissipation in three models with increasing complexity: the classical closed model, the open corona, and the open corona including chromosphere (or three-layer model), with the last two models allowing energy leakage. Results: We find that (i) leakage always plays a role. Even for strong turbulence, the dissipation time never becomes much lower than the leakage time, at least in the three-layer model; therefore, both the energy and the dissipation levels are systematically lower than in the line-tied model; (ii) in all models, the energy level is close to the resonant prediction, i.e., assuming an effective turbulent correlation time longer than the Alfvén coronal crossing time; (iii) the heating rate is close to the value given by the ratio of photospheric energy divided by the Alfv

  6. 78 FR 13402 - Proposed Collection; Comment Request for Tip Reporting Alternative Tip Agreement Used in the...

    Science.gov (United States)

    2013-02-27

    ... Used in the Cosmetology and Barber Industry AGENCY: Internal Revenue Service (IRS), Treasury. ACTION..., the IRS is soliciting comments concerning tip reporting alternative commitment used in the cosmetology...: Tip Reporting Alternative Commitment Agreement used in the Cosmetology and Barber Industry. OMB Number...

  7. 75 FR 11226 - Proposed Collection; Comment Request for Tip Reporting Alternative Tip Agreement Used in the...

    Science.gov (United States)

    2010-03-10

    ... Used in the Cosmetology and Barber Industry AGENCY: Internal Revenue Service (IRS), Treasury. ACTION..., the IRS is soliciting comments concerning Tip Reporting Alternative Commitment used in the Cosmetology...: Tip Reporting Alternative Commitment Agreement used in the Cosmetology and Barber Industry. OMB Number...

  8. A Rotor Tip Vortex Tracing Algorithm for Image Post-Processing

    Science.gov (United States)

    Overmeyer, Austin D.

    2015-01-01

    A neurite tracing algorithm, originally developed for medical image processing, was used to trace the location of the rotor tip vortex in density gradient flow visualization images. The tracing algorithm was applied to several representative test images to form case studies. The accuracy of the tracing algorithm was compared to two current methods including a manual point and click method and a cross-correlation template method. It is shown that the neurite tracing algorithm can reduce the post-processing time to trace the vortex by a factor of 10 to 15 without compromising the accuracy of the tip vortex location compared to other methods presented in literature.

  9. Hydrochemical Impacts of CO2 Leakage on Fresh Groundwater: a Field Scale Experiment

    Science.gov (United States)

    Lions, J.; Gal, F.; Gombert, P.; Lafortune, S.; Darmoul, Y.; Prevot, F.; Grellier, S.; Squarcioni, P.

    2013-12-01

    One of the questions related to the emerging technology for Carbon Geological Storage concerns the risk of CO2 migration beyond the geological storage formation. In the event of leakage toward the surface, the CO2 might affect resources in neighbouring formations (geothermal or mineral resources, groundwater) or even represent a hazard for human activities at the surface or in the subsurface. In view of the preservation of the groundwater resources mainly for human consumption, this project studies the potential hydrogeochemical impacts of CO2 leakage on fresh groundwater quality. One of the objectives is to characterize the bio-geochemical mechanisms that may impair the quality of fresh groundwater resources in case of CO2 leakage. To reach the above mentioned objectives, this project proposes a field experiment to characterize in situ the mechanisms that could impact the water quality, the CO2-water-rock interactions and also to improve the monitoring methodology by controlled CO2 leakage in shallow aquifer. The tests were carried out in an experimental site in the chalk formation of the Paris Basin. The site is equipped with an appropriate instrumentation and was previously characterized (8 piezometers, 25 m deep and 4 piezairs 11 m deep). The injection test was preceded by 6 months of monitoring in order to characterize hydrodynamics and geochemical baselines of the site (groundwater, vadose and soil). Leakage into groundwater is simulated via the injection of a small quantity of food-grade CO2 (~20 kg dissolved in 10 m3 of water) in the injection well at a depth of about 20 m. A plume of dissolved CO2 is formed and moves downward according to the direction of groundwater flow and probably by degassing in part to the surface. During the injection test, hydrochemical monitoring of the aquifer is done in situ and by sampling. The parameters monitored in the groundwater are the piezometric head, temperature, pH and electrical conductivity. Analysis on water

  10. Perioperative Statin Therapy Is Not Associated With Reduced Risk of Anastomotic Leakage After Colorectal Resection

    DEFF Research Database (Denmark)

    Bisgård, Anne Sofie; Noack, Morten Westergaard; Klein, Mads

    2013-01-01

    Anastomotic leakage is a serious complication of colorectal surgery. Several studies have demonstrated the beneficial pleiotropic effects of statins, and preliminary studies have suggested that perioperative statin treatment may be associated with reduced risk of anastomotic leakage....

  11. Intraoperative and postoperative risk factors for anastomotic leakage and pneumonia after esophagectomy for cancer

    NARCIS (Netherlands)

    Goense, L.; van Rossum, P. S N; Tromp, M.; Joore, JCA; van Dijk, D.; Kroese, A. C.; Ruurda, J. P.; van Hillegersberg, R.

    Morbidity and mortality after esophagectomy are often related to anastomotic leakage or pneumonia. This study aimed to assess the relationship of intraoperative and postoperative vital parameters with anastomotic leakage and pneumonia after esophagectomy. Consecutive patients who underwent

  12. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events

    OpenAIRE

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while c...

  13. Loading and leakage of krypton immobilized in zeolites and glass

    International Nuclear Information System (INIS)

    Christensen, A.B.; Del Debbio, J.A.; Knecht, D.A.; Tanner, J.E.

    1980-01-01

    Krypton-85 is formed in nuclear power reactors and remains trapped until the fuel is reprocessed. Federal regulations limit the release of 85 Kr to the environment, requiring recovery and storage of 85% of the 85 Kr produced in commercial light-water reactors after January 1, 1983. One of the long-term storage options involves encapsulating 85 Kr in zeolites or glasses at high pressure and temperature. This paper presents experimental results for krypton encapsulation and leakage in sodalite, zeolite 5A, and Vycor Thristy glass. The results show that all three materials are feasible for 85 Kr immobilization and long-term storage, although zeolite 5A and Thirsty Vycor are preferable due to lower leakage rates

  14. Distributed public key schemes secure against continual leakage

    DEFF Research Database (Denmark)

    Akavia, Adi; Goldwasser, Shafi; Hazay, Carmit

    2012-01-01

    In this work we study distributed public key schemes secure against continual memory leakage. The secret key will be shared among two computing devices communicating over a public channel, and the decryption operation will be computed by a simple 2-party protocol between the devices. Similarly...... the value of the respective function on the internal state of the respective device (namely, on its secret share, internal randomness, and results of intermediate computations). We present distributed public key encryption (DPKE) and distributed identity based encryption (DIBE) schemes that are secure......-secure against continual memory leakage. Our DPKE scheme also implies a secure storage system on leaky devices, where a value s can be secretely stored on devices that continually leak information about their internal state to an external attacker. The devices go through a periodic refresh protocol...

  15. The Impact of Statistical Leakage Models on Design Yield Estimation

    Directory of Open Access Journals (Sweden)

    Rouwaida Kanj

    2011-01-01

    Full Text Available Device mismatch and process variation models play a key role in determining the functionality and yield of sub-100 nm design. Average characteristics are often of interest, such as the average leakage current or the average read delay. However, detecting rare functional fails is critical for memory design and designers often seek techniques that enable accurately modeling such events. Extremely leaky devices can inflict functionality fails. The plurality of leaky devices on a bitline increase the dimensionality of the yield estimation problem. Simplified models are possible by adopting approximations to the underlying sum of lognormals. The implications of such approximations on tail probabilities may in turn bias the yield estimate. We review different closed form approximations and compare against the CDF matching method, which is shown to be most effective method for accurate statistical leakage modeling.

  16. Correlation among ESDD, NSDD and leakage current in distribution insulators

    International Nuclear Information System (INIS)

    Montoya, G.; Ramirez, I.; Montoya, J.I.

    2004-01-01

    The maintenance of distribution networks is more effective if the insulation contamination levels are known. The selection of measuring methods of pollution levels is then crucial. The relationship between several evaluation methods of pollution levels and the operating behaviour of several insulator profiles in a polluted zone is described. Laboratory tests were carried out to reproduce pollution levels found in the field. The quantity of non-soluble materials deposited over the insulators' surface affect the magnitude of the leakage current generated over a contaminated insulator. The relationship that defines leakage current with respect to the equivalent salt deposit density (ESDD) level for a specific non-soluble material level is almost linear, from which it is possible to develop a relationship between them for each insulator. (author)

  17. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P.; Vranka, L. [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1997-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  18. Modelling of Consequences of Biogas Leakage from Gasholder

    Directory of Open Access Journals (Sweden)

    Petr Trávníček

    2017-03-01

    Full Text Available This paper describes modelling of consequences of biogas leakage from a gasholder on agricultural biogas station. Four scenarios were selected for the purpose of this work. A rupture of gasholders membrane and instantaneous explosion of gas cloud, blast of gas with delay, emptying of whole volume of gas (without initiation and initiation of gas with Jet-Fire. Leakage of gas is modelled by special software and consequences are determined on the basis of results. The first scenario was modelled with help of equations because used software does not include an appropriate model. A farm with high building density was chosen as a model case. Biogas is replaced by methane because used software does not support modelling of dispersion of mixtures. From this viewpoint, a conservative approach is applied because biogas contains “only” approximately 60% of methane (in dependence on technology and processed material.

  19. Tip vortices in the actuator line model

    Science.gov (United States)

    Martinez, Luis; Meneveau, Charles

    2017-11-01

    The actuator line model (ALM) is a widely used tool to represent the wind turbine blades in computational fluid dynamics without the need to resolve the full geometry of the blades. The ALM can be optimized to represent the `correct' aerodynamics of the blades by choosing an appropriate smearing length scale ɛ. This appropriate length scale creates a tip vortex which induces a downwash near the tip of the blade. A theoretical frame-work is used to establish a solution to the induced velocity created by a tip vortex as a function of the smearing length scale ɛ. A correction is presented which allows the use of a non-optimal smearing length scale but still provides the downwash which would be induced using the optimal length scale. Thanks to the National Science Foundation (NSF) who provided financial support for this research via Grants IGERT 0801471, IIA-1243482 (the WINDINSPIRE project) and ECCS-1230788.

  20. Tipping elements in the Arctic marine ecosystem.

    Science.gov (United States)

    Duarte, Carlos M; Agustí, Susana; Wassmann, Paul; Arrieta, Jesús M; Alcaraz, Miquel; Coello, Alexandra; Marbà, Núria; Hendriks, Iris E; Holding, Johnna; García-Zarandona, Iñigo; Kritzberg, Emma; Vaqué, Dolors

    2012-02-01

    The Arctic marine ecosystem contains multiple elements that present alternative states. The most obvious of which is an Arctic Ocean largely covered by an ice sheet in summer versus one largely devoid of such cover. Ecosystems under pressure typically shift between such alternative states in an abrupt, rather than smooth manner, with the level of forcing required for shifting this status termed threshold or tipping point. Loss of Arctic ice due to anthropogenic climate change is accelerating, with the extent of Arctic sea ice displaying increased variance at present, a leading indicator of the proximity of a possible tipping point. Reduced ice extent is expected, in turn, to trigger a number of additional tipping elements, physical, chemical, and biological, in motion, with potentially large impacts on the Arctic marine ecosystem.

  1. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  2. Thermogenic Wet Gas in Immature Caprock Sections: Leakage or Generation.

    Science.gov (United States)

    Abrakasa, Selegha; Beka, Francis; Ndukauba, Egesi

    2017-04-01

    Gas geochemistry, an aspect of Petroleum Geoscience is a growing science, various concepts has been used to evaluation potential source rock for shale gas while in conventional petroleum exploration similar concepts have been used to determine potential productive formation for liquid hydrocarbons. Prior to the present times, headspace gas data had been used to recognize by pass pays, serve as indicators of petroleum accumulations, evaluate maturity and productive capacity of corresponding formations, evaluate the maturity and source of gas accumulations. Integrating studies in bid to achieve high degree of accuracy, data on direct hydrocarbon indicators (DHIs) such as oil stains, oil shows and seeps have been employed. Currently popular among professionals is the use of gas clouds on seismic cross sections. In contemporary times, advancement in gas geochemistry has witnessed the application of concepts on headspace gas to expound the efficiency of petroleum caprocks whose major role is to foster accumulation and preservation. This enables extricating potential leakage mechanism via caprock reservoir interface and unravel its corresponding migrational pathways. In this study thermogenic wet gas has been used as a dependable tool for delineating caprock leakage by discriminating migrant from indigenous hydrocarbons in caprock rock sections overlying the reservoirs. The thermogenic gas profile in corroboration with the thermogenic signature and maturity data were used. Summary statistics indicates that 60% of the 50 wells studied has wet gas up to 500m above the reservoir-caprock interface and 10% of the leaking wells are fracture prone leakage.The amount of wet gas ranges of up to 200,000 ppm in the caprock sections, this indicates pervasive leakage. Log view plots were modelled using Schlumbergers' Techlog, while descriptive lithologies were modeled using Zetawares' genesis.

  3. Investigation of carrier mobility degradation effects on MOSFET leakage simulations

    CSIR Research Space (South Africa)

    Twala, B

    2016-01-01

    Full Text Available of electric field, carrier temperature and impact ionization. 4. Several vertical grid spacing inside the gate oxide when simulating gate field effects such as gate induced drain leakage (GIDL) or using any hot electron or tunneling gate current models... on its gain and is proportional to the hole or electron mobility (depending on device type); at least for low drain voltages. The transverse field dependent mobility models are of particular importance for simulating MOS devices. Because the reduction...

  4. Deforestation, Leakage and Avoided Deforestation Policies: A Spatial Analysis

    OpenAIRE

    Philippe Delacote; Elizabeth J. Z. Robinson; Sébastien Roussel

    2015-01-01

    This paper analyses the impact of several avoided deforestation policies within a patchy forested landscape. Central is the idea that one neighbour's deforestation actions may impact the returns to deforestation in nearby patches. We determine the impact of each policy in terms of avoided deforestation and leakage levels at the landscape scale through modelling and simulations. Avoided deforestation policies at a landscape level are respectively: two Payment for Environmental Services (PES) p...

  5. Breakdown of equipartition in diffuse fields caused by energy leakage

    Science.gov (United States)

    Margerin, L.

    2017-05-01

    Equipartition is a central concept in the analysis of random wavefields which stipulates that in an infinite scattering medium all modes and propagation directions become equally probable at long lapse time in the coda. The objective of this work is to examine quantitatively how this conclusion is affected in an open waveguide geometry, with a particular emphasis on seismological applications. To carry our this task, the problem is recast as a spectral analysis of the radiative transfer equation. Using a discrete ordinate approach, the smallest eigenvalue and associated eigenfunction of the transfer equation, which control the asymptotic intensity distribution in the waveguide, are determined numerically with the aid of a shooting algorithm. The inverse of this eigenvalue may be interpreted as the leakage time of the diffuse waves out of the waveguide. The associated eigenfunction provides the depth and angular distribution of the specific intensity. The effect of boundary conditions and scattering anisotropy is investigated in a series of numerical experiments. Two propagation regimes are identified, depending on the ratio H∗ between the thickness of the waveguide and the transport mean path in the layer. The thick layer regime H∗ > 1 has been thoroughly studied in the literature in the framework of diffusion theory and is briefly considered. In the thin layer regime H∗ parallel to the surface and equipartition breaks down. Qualitatively, the anisotropy of the intensity field is found to increase with the inverse non-dimensional leakage time, with the scattering mean free time as time scale. Because it enhances leakage, a rough free surface may result in stronger anisotropy of the intensity field than a flat surface, for the same bulk scattering properties. Our work identifies leakage as a potential explanation for the large deviation from isotropy observed in the coda of body waves.

  6. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage ...

  7. A Minimum Leakage Quasi-Static RAM Bitcell

    Directory of Open Access Journals (Sweden)

    Adam Teman

    2011-05-01

    Full Text Available As SRAMs continue to grow and comprise larger percentages of the area and power consumption in advanced systems, the need to minimize static currents becomes essential. This brief presents a novel 9T Quasi-Static RAM Bitcell that provides aggressive leakage reduction and high write margins. The quasi-static operation method of this cell, based on internal feedback and leakage ratios, minimizes static power while maintaining sufficient, albeit depleted, noise margins. This paper presents the concept of the novel cell, and discusses the stability of the cell under hold, read and write operations. The cell was implemented in a low-power 40 nm TSMC process, showing as much as a 12× reduction in leakage current at typical conditions, as compared to a standard 6T or 8T bitcell at the same supply voltage. The implemented cell showed full functionality under global and local process variations at nominal and low voltages, as low as 300 mV.

  8. Pore formation by T3SS translocators: liposome leakage assay.

    Science.gov (United States)

    Faudry, Eric; Perdu, Caroline; Attrée, Ina

    2013-01-01

    Gram-negative bacteria utilize a dedicated membrane-embedded apparatus, the type III secretion system (T3SS), to inject proteins into host cells. The passage of the proteins across the target membrane is accomplished by a proteinaceous pore-the translocon-formed within the host-cell cytoplasmic membrane. Translocators bound to their chaperones can be expressed in Escherichia coli and subsequently dissociated from the chaperone by guanidine treatment. The pore formation properties of the translocators can then be studied by an in-vitro liposome leakage assay. Sulforhodamine-B is encapsulated within lipid vesicles during liposome preparation. At high concentration, this fluorochrome exhibits self-quenching limiting fluorescence emission. Upon pore formation, liposome leakage leads to the dilution of Sulforhodamine-B in the medium and fluorescence emission increases. Alternatively, fluorochromes coupled to large dextran molecules can be encapsulated in order to estimate pore dimensions. Here we describe protein expression and purification, dye-liposome preparation, and leakage assay conditions.

  9. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  10. Experimental study on the leakage of gas through cracked concrete walls

    International Nuclear Information System (INIS)

    Suzuki, T.; Takiguchi, K.; Hotta, H.; Kojima, N.; Fukuhara, M.; Kimura, K.

    1989-01-01

    The air-tightness of concrete walls is important for nuclear-related facilities. A concrete wall has very high probabilities of developing cracks due to shrinkage, seismic forces or other factors. It is therefore essential to be able to predict the amount of gas which will leak through a cracked concrete wall. In the previous paper published in SmiRT-9, the experimental equation on the gas leakage through a single crack occurred in concrete was presented based on two-dimensional Poiseuille's flow. In this paper, the experimental results were examined again considering the compressibility of gas, and new equation is presented. The experiments which were similar to ones in the previous paper were carried out on several kinds of concrete using several kinds of gases, and the effects of the kinds of gaseous body, particle size of aggregates and shape of aggregates were examined

  11. Tip-Based Nanofabrication for Scalable Manufacturing

    Directory of Open Access Journals (Sweden)

    Huan Hu

    2017-03-01

    Full Text Available Tip-based nanofabrication (TBN is a family of emerging nanofabrication techniques that use a nanometer scale tip to fabricate nanostructures. In this review, we first introduce the history of the TBN and the technology development. We then briefly review various TBN techniques that use different physical or chemical mechanisms to fabricate features and discuss some of the state-of-the-art techniques. Subsequently, we focus on those TBN methods that have demonstrated potential to scale up the manufacturing throughput. Finally, we discuss several research directions that are essential for making TBN a scalable nano-manufacturing technology.

  12. Social tipping points and Earth systems dynamics

    Directory of Open Access Journals (Sweden)

    R. Alexander eBentley

    2014-08-01

    Full Text Available Recently, Early Warning Signals (EWS have been developed to predict tipping points in Earth Systems. This discussion highlights the potential to apply EWS to human social and economic systems, which may also undergo similar critical transitions. Social tipping points are particularly difficult to predict, however, and the current formulation of EWS, based on a physical system analogy, may be insufficient. As an alternative set of EWS for social systems, we join with other authors encouraging a focus on heterogeneity, connectivity through social networks and individual thresholds to change.

  13. Windows 7 Annoyances Tips, Secrets, and Solutions

    CERN Document Server

    Karp, David

    2010-01-01

    Windows 7 may be faster and more stable than Vista, but it's a far cry from problem-free. David A. Karp comes to the rescue with the latest in his popular Windows Annoyances series. This thorough guide gives you the tools you need to fix the troublesome parts of this operating system, plus the solutions, hacks, and timesaving tips to make the most of your PC. Streamline Windows Explorer, improve the Search tool, eliminate the Green Ribbon of Death, and tame User Account Control promptsExplore powerful Registry tips and tools, and use them to customize every aspect of Windows and solve its sho

  14. Numerical simulation of the tip aerodynamics and acoustics test

    Science.gov (United States)

    Tejero E, F.; Doerffer, P.; Szulc, O.; Cross, J. L.

    2016-04-01

    The application of an efficient flow control system on helicopter rotor blades may lead to improved aerodynamic performance. Recently, our invention of Rod Vortex Generators (RVGs) has been analyzed for helicopter rotor blades in hover with success. As a step forward, the study has been extended to forward flight conditions. For this reason, a validation of the numerical modelling for a reference helicopter rotor (without flow control) is needed. The article presents a study of the flow-field of the AH-1G helicopter rotor in low-, medium- and high-speed forward flight. The CFD code FLOWer from DLR has proven to be a suitable tool for the aerodynamic analysis of the two-bladed rotor without any artificial wake modelling. It solves the URANS equations with LEA (Linear Explicit Algebraic stress) k-ω model using the chimera overlapping grids technique. Validation of the numerical model uses comparison with the detailed flight test data gathered by Cross J. L. and Watts M. E. during the Tip Aerodynamics and Acoustics Test (TAAT) conducted at NASA in 1981. Satisfactory agreements for all speed regimes and a presence of significant flow separation in high-speed forward flight suggest a possible benefit from the future implementation of RVGs. The numerical results based on the URANS approach are presented not only for a popular, low-speed case commonly used in rotorcraft community for CFD codes validation but preferably for medium- and high-speed test conditions that have not been published to date.

  15. Turbine blade squealer tip rail with fence members

    Science.gov (United States)

    Little, David A

    2012-11-20

    A turbine blade includes an airfoil, a blade tip section, a squealer tip rail, and a plurality of chordally spaced fence members. The blade tip section includes a blade tip floor located at an end of the airfoil distal from the root. The blade tip floor includes a pressure side and a suction side joined together at chordally spaced apart leading and trailing edges of the airfoil. The squealer tip rail extends radially outwardly from the blade tip floor adjacent to the suction side and extends from a first location adjacent to the airfoil trailing edge to a second location adjacent to the airfoil leading edge. The fence members are located between the airfoil leading and trailing edges and extend radially outwardly from the blade tip floor and axially from the squealer tip rail toward the pressure side.

  16. Dielectrophoretic positioning of single nanoparticles on atomic force microscope tips for tip-enhanced Raman spectroscopy.

    Science.gov (United States)

    Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang

    2015-05-01

    Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Tip off the HAT- Epigenetic control of learning and memory by Drosophila Tip60.

    Science.gov (United States)

    Xu, Songjun; Elefant, Felice

    2015-01-01

    Disruption of epigenetic gene control mechanisms involving histone acetylation in the brain causes cognitive impairment, a debilitating hallmark of most neurodegenerative disorders. Histone acetylation regulates cognitive gene expression via chromatin packaging control in neurons. Unfortunately, the histone acetyltransferases (HATs) that generate such neural epigenetic signatures and their mechanisms of action remain unclear. Our recent findings provide insight into this question by demonstrating that Tip60 HAT action is critical for morphology and function of the mushroom body (MB), the learning and memory center in the Drosophila brain. We show that Tip60 is robustly produced in MB Kenyon cells and extending axonal lobes and that targeted MB Tip60 HAT loss results in axonal outgrowth disruption. Functional consequences of loss and gain of Tip60 HAT levels in the MB are evidenced by defects in memory. Tip60 ChIP-Seq analysis reveals enrichment for genes that function in cognitive processes and accordingly, key genes representing these pathways are misregulated in the Tip60 HAT mutant fly brain. Remarkably, increasing levels of Tip60 in the MB rescues learning and memory deficits resulting from Alzheimer's disease associated amyloid precursor protein (APP) induced neurodegeneration. Our studies highlight the potential of HAT activators as a therapeutic option for cognitive disorders.

  18. Tip opening of premixed bunsen flames: Extinction with negative stretch and local Karlovitz number

    KAUST Repository

    Vu, Tranmanh

    2015-04-01

    The characteristics of tip openings in premixed bunsen flames have been studied experimentally by measuring OH radicals from laser-induced fluorescence and tip curvatures from chemiluminescent images. Results showed that the tip opening occurred at a constant equivalence ratio and was independent of the jet velocity in propane/air mixtures. The observation of a local extinction phenomenon of the negatively stretched flame due to the flame curvature could not be consistently explained based on flame stretch or the Karlovitz number, since they varied appreciably with the jet velocity. The concept of the local Karlovitz number (KaL) was introduced, which is defined as the ratio of the characteristic reaction time in the normal direction for a stretched flame to the characteristic flow time in the tangential direction for the stretched flame. The local Karlovitz number maintained a constant value under tip opening conditions, irrespective of the jet velocity. Tip opening occurred at a reasonably constant local Karlovitz number of about ~1.72 when the nitrogen dilution level in propane and n-butane fuels was varied.

  19. A translating stage system for µ-PIV measurements surrounding the tip of a migrating semi-infinite bubble.

    Science.gov (United States)

    Smith, B J; Yamaguchi, E; Gaver, D P

    2010-01-01

    We have designed, fabricated and evaluated a novel translating stage system (TSS) that augments a conventional micro particle image velocimetry (µ-PIV) system. The TSS has been used to enhance the ability to measure flow fields surrounding the tip of a migrating semi-infinite bubble in a glass capillary tube under both steady and pulsatile reopening conditions. With conventional µ-PIV systems, observations near the bubble tip are challenging because the forward progress of the bubble rapidly sweeps the air-liquid interface across the microscopic field of view. The translating stage mechanically cancels the mean bubble tip velocity, keeping the interface within the microscope field of view and providing a tenfold increase in data collection efficiency compared to fixed-stage techniques. This dramatic improvement allows nearly continuous observation of the flow field over long propagation distances. A large (136-frame) ensemble-averaged velocity field recorded with the TSS near the tip of a steadily migrating bubble is shown to compare well with fixed-stage results under identical flow conditions. Use of the TSS allows the ensemble-averaged measurement of pulsatile bubble propagation flow fields, which would be practically impossible using conventional fixed-stage techniques. We demonstrate our ability to analyze these time-dependent two-phase flows using the ensemble-averaged flow field at four points in the oscillatory cycle.

  20. Geological and geophysical investigation of water leakage from two micro-dam reservoirs: Implications for future site selection, northern Ethiopia

    Science.gov (United States)

    Berhane, Gebremedhin; Amare, Mogos; Gebreyohannes, Tesfamichael; Walraevens, Kristine

    2017-05-01

    Water resources are essential to human development activities and to eradicate extreme poverty and hunger. Geological problems of two water harvesting Micro-Dam Reservoirs (MDRs) were evaluated from leakage perspectives in the northern part of Ethiopia, East Africa. Conventional geological mapping, discontinuity and weathering descriptions, test pits and geophysical methods were used to characterize the hydrogeological features of the MDRs. Vertical Electrical Sounding (VES) and Electrical Profiling (EP), were executed using Terrameter SAS (signal averaging system) 1000 manufactured by ABEM, Sweden, with Schlumberger and Wenner array configuration respectively. It was concluded that the foundations of both MDRs, except the right abutment for Adishuhu which is partly composed of dolerite, are pervious due to the presence of thin bedding planes, joints, weathered materials and fault. The presence of water in the downstream toe of the MDRs, at depressions, existing test pits and test pits excavated during the present study which lie within the seepage zone demarcated during surface geological mapping, correspond with the electrical resistivity study. The results of the electrical resistivity survey (EP and VES) were merged with the geological and structural mapping and the observation of seepage zones, for the delineation of weak zones responsible for leakage. Monitoring of the leakage (reservoir water and groundwater levels), both manually and using automatic divers, is recommended, along with monitoring of the stability of the embankments and the discharge or flow downstream of the MDRs.