WorldWideScience

Sample records for tip clearance control

  1. Tip Clearance Control Using Plasma Actuators

    Science.gov (United States)

    2007-03-01

    Clearance Control Using Plasma Actuators 4 posed by Denton (1993). A number of investigators have used partial shrouds, or " winglet " designs to...SDBD actuator Plasma enhanced aerodynamics has been demonstrated in a range of applications involving sepa- ration control, lift enhancement, drag... aerodynamic benefits of a squealer tip geometry. Specifically, the squealer tip is known to reduce the discharge coefficient of the tip gap, thereby

  2. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  3. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  4. A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

    Science.gov (United States)

    Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei

    2017-01-01

    The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

  5. Compressor airfoil tip clearance optimization system

    Science.gov (United States)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  6. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  7. Centrifugal compressor tip clearance and impeller flow

    International Nuclear Information System (INIS)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari; Engeda, Abraham

    2016-01-01

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease

  8. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    Science.gov (United States)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  9. Tip clearance effect on through-flow and performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Young Seok; Kang, Shin Hyoung

    2004-01-01

    Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency

  10. Numerical study on tip clearance effect on performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Shin Kyoung

    2003-01-01

    Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASCflow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected performance equally, while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully

  11. Turbo machine tip clearance and vibration measurements using a fibre optic laser Doppler position sensor

    Science.gov (United States)

    Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.

    2006-07-01

    This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.

  12. Turbulent Heat Transfer of a Finned Plate in a Duct as Tip Clearance Changes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae-Kyun; Chung, Bum-Jin [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    Fins are employed to enhance the cooling performance of a system. There are a number of studies relevant to geometry of fins. Meanwhile, the studies relevant to tip clearance, have not performed enough, which is the distance between the tips of the fins and the wall. We investigated the optimal tip clearance, which maximizes the heat transfers by experimental and numerical analyses with wider range of Re{sub Dh} than the previous studies. Turbulent heat transfers of a finned plate were measured. For an extended range of tip clearance and Re{sub Dh} than other studies. A joint experimental and numerical analyses was performed to measure heat transfers. Mass transfer experiments using electroplating system was used and FLUENT 6.3.26 was used for the calculation. For the narrow tip clearances below 5 mm, were investigated by numerical method only. The bypass flow to the tip clearance region contributes to heat transfer area at the tip clearance region and does not contributes that of the fin region. Thus, the optimal tip clearance was founded and it exists vicinity of 0.2 mm.

  13. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    Science.gov (United States)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  14. Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

    Science.gov (United States)

    Woike, Mark R.; Roeder, James W.; Hughes, Christopher E.; Bencic, Timothy J.

    2009-01-01

    The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

  15. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  16. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    Science.gov (United States)

    Erler, Engin

    Tip clearance flow is the flow through the clearance between the rotor blade tip and the shroud of a turbomachine, such as compressors and turbines. This flow is driven by the pressure difference across the blade (aerodynamic loading) in the tip region and is a major source of loss in performance and aerodynamic stability in axial compressors of modern aircraft engines. An increase in tip clearance, either temporary due to differential radial expansion between the blade and the shroud during transient operation or permanent due to engine wear or manufacturing tolerances on small blades, increases tip clearance flow and results in higher fuel consumption and higher risk of engine surge. A compressor design that can reduce the sensitivity of its performance and aerodynamic stability to tip clearance increase would have a major impact on short and long-term engine performance and operating envelope. While much research has been carried out on improving nominal compressor performance, little had been done on desensitization to tip clearance increase beyond isolated observations that certain blade designs such as forward chordwise sweep, seem to be less sensitive to tip clearance size increase. The current project aims to identify through a computational study the flow features and associated mechanisms that reduces sensitivity of axial compressor rotors to tip clearance size and propose blade design strategies that can exploit these results. The methodology starts with the design of a reference conventional axial compressor rotor followed by a parametric study with variations of this reference design through modification of the camber line and of the stacking line of blade profiles along the span. It is noted that a simple desensitization method would be to reduce the aerodynamic loading of the blade tip which would reduce the tip clearance flow and its proportional contribution to performance loss. However, with the larger part of the work on the flow done in this

  17. Experimental Investigation of Factors Influencing Operating Rotor Tip Clearance in Multistage Compressors

    Directory of Open Access Journals (Sweden)

    Reid A. Berdanier

    2015-01-01

    Full Text Available An analysis of compressor rotor tip clearance measurements using capacitance probe instrumentation is discussed for a three-stage axial compressor. Thermal variations and centrifugal effects related to rotational speed changes affect clearance heights relative to the assembled configuration. These two primary contributions to measured changes are discussed both independently and in combination. Emphasis is given to tip clearance changes due to changing loading condition and at several compressor operating speeds. Measurements show a tip clearance change approaching 0.1 mm (0.2% rotor span when comparing a near-choke operating condition to a near-stall operating condition for the third stage. Additional consideration is given to environmental contributions such as ambient temperature, for which changes in tip clearance height on the order of 0.05 mm (0.1% rotor span were noted for temperature variations of 15°C. Experimental compressor operating clearances are presented for several temperatures, operating speeds, and loading conditions, and comparisons are drawn between these measured variations and predicted changes under the same conditions.

  18. An Optical Fiber Bundle Sensor for Tip Clearance and Tip Timing Measurements in a Turbine Rig

    Directory of Open Access Journals (Sweden)

    María Asunción Illarramendi

    2013-06-01

    Full Text Available When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions.

  19. Losses and blade tip clearance for a centrifugal compressor

    Directory of Open Access Journals (Sweden)

    Oana DUMITRESCU

    2018-06-01

    Full Text Available The present paper presents the numerical analysis for a transonic centrifugal compressor using steady state CFD. The blade tip clearance effect over the position of shock waves, tip losses and the performances of the impeller are studied. Numerical simulations have been performed using RANS modelling, with the k-omega SST turbulence model (Shear Stress Transport. Eight cases were taken into consideration for the impeller with the following blade tip clearances values: 0 mm, 0.1 mm, 0.3 mm, 0.4 mm, 0.5mm, 0.7 mm, 1 mm, 2 mm, at the same operating conditions. For the entire stage only seven cases were studied, without the value for 0.1 mm because of its abnormal behaviour, as can be seen in the case of the impeller simulations. Results showed that the position of the shock wave does not change with the increase of the tip clearance. Aerodynamic losses due to shock wave, secondary flow and turbulence can be seen in the polytropic efficiency of the centrifugal impeller and the difference between the two extreme cases is about 3.2 %.

  20. Influence of tip clearance on flow behavior and noise generation of centrifugal compressors in near-surge conditions

    International Nuclear Information System (INIS)

    Galindo, J.; Tiseira, A.; Navarro, R.; López, M.A.

    2015-01-01

    Highlights: • Centrifugal compressor aeroacoustics sensitivity to tip clearance is investigated. • 3 different clearance ratios are set in accordance to expected operating values. • Pressure spectra do not depend on tip clearance ratio in near-surge conditions. • DES performs better than URANS in predicting compressor acoustic signature. • Flow field observation reveals that tip clearance is immersed in rotating backflow. - Abstract: CFD has become an essential tool for researchers to analyze centrifugal compressors. Tip leakage flow is usually considered one of the main mechanisms that dictate compressor flow field and stability. However, it is a common practice to rely on CAD tip clearance, even though the gap between blades and shroud changes when compressor is running. In this paper, sensitivity of centrifugal compressor flow field and noise prediction to tip clearance ratio is investigated. 3D CFD simulations are performed with three different tip clearance ratios in accordance to expected operating values, extracted from shaft motion measurements and FEM predictions of temperature and rotational deformation. Near-surge operating conditions are simulated with URANS and DES. DES shows superior performance for acoustic predictions. Cases with reduced tip clearance present higher pressure ratio and isentropic efficiency, but no significant changes in compressor acoustic signature are found when varying clearance. In this working point, tip clearance is immersed in a region of strongly swirling backflow. Therefore, tip leakage cannot establish any coherent noise source mechanism

  1. Energy Performance and Radial Force of a Mixed-Flow Pump with Symmetrical and Unsymmetrical Tip Clearances

    Directory of Open Access Journals (Sweden)

    Yue Hao

    2017-01-01

    Full Text Available The energy performance and radial force of a mixed flow pump with symmetrical and unsymmetrical tip clearance are investigated in this paper. As the tip clearance increases, the pump head and efficiency both decrease. The center of the radial force on the principal axis is located at the coordinate origin when the tip clearance is symmetrical, and moves to the third quadrant when the tip clearance is unsymmetrical. Analysis results show that the total radial force on the principal axis is closely related to the fluctuation of mass flow rate in each single flow channel. Unsteady simulations show that the dominant frequencies of radial force on the hub and blade correspond to the blade number, vane number, or double blade number because of the rotor stator interaction. The radial force on the blade pressure side decreases with the tip clearance increase because of leakage flow. The unsymmetrical tip clearances in an impeller induce uneven leakage flow rate and then result in unsymmetrical work ability of each blade and flow pattern in each channel. Thus, the energy performance decreases and the total radial force increases for a mixed flow pump with unsymmetrical tip clearance.

  2. Effects of a Nonuniform Tip Clearance Profile on the Performance and Flow Field in a Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    Yohan Jung

    2012-01-01

    Full Text Available This paper presents a numerical investigation of the effects of a nonuniform tip clearance profile on the performance and flow field in a centrifugal compressor with a vaneless diffuser. This study focuses in particular on the magnitude and location of the wake. Six impellers with different tip clearance profiles were tested in the flow simulations. The accuracy of the numerical simulations was assessed by comparing the experimental data with the computational results for a system characterized by the original tip clearance. Although the performance improved for low tip clearances, a low tip clearance at the trailing edge improved the compressor performance more significantly than a low tip clearance at the leading edge. The flow field calculated for a system characterized by a low tip clearance at the trailing edge produced a more uniform velocity distribution both in the circumferential and in the axial directions at the impeller exit because the wake magnitude was reduced. As a consequence, this impeller provided a better potential for diffusion processes inside a vaneless diffuser.

  3. Axial compressor gas path design for desensitization of aerodynamic performance and stability to tip clearance

    Science.gov (United States)

    Cevik, Mert

    Tip clearance is the necessary small gap left between the moving rotor tip and stationary shroud of a turbomachine. In a compressor, the pressure driven flow through this gap, called tip clearance flow, has a major and generally detrimental impact on compressor performance (pressure ratio and efficiency) and aerodynamic stability (stall margin). The increase in tip clearance, either temporary during transient engine operations or permanent from wear, leads to a drop in compressor performance and aerodynamic stability which results in a fuel consumption increase and a reduced operating envelope for a gas turbine engine. While much research has looked into increasing compressor performance and stall margin at the design (minimum or nominal) tip clearance, very little attention has been paid for reducing the sensitivity of these parameters to tip clearance size increase. The development of technologies that address this issue will lead to aircraft engines whose performance and operating envelope are more robust to operational demands and wear. The current research is the second phase of a research programme to develop design strategies to reduce the sensitivity of axial compressor performance and aerodynamic stability to tip clearance. The first phase had focused on blade design strategies and had led to the discovery and explanation of two flow features that reduces tip sensitivity, namely increased incoming meridional momentum in the rotor tip region and reduction/elimination of double leakage. Double leakage is the flow that exits one tip clearance and enters the tip clearance of the adjacent blade instead of convecting downstream out of the rotor passage. This flow was shown to be very detrimental to compressor performance and stall margin. Two rotor design strategies involving sweep and tip stagger reduction were proposed and shown by CFD simulations to exploit these features to reduce sensitivity. As the second phase, the objectives of the current research

  4. Rotating coherent flow structures as a source for narrowband tip clearance noise from axial fans

    Science.gov (United States)

    Zhu, Tao; Lallier-Daniels, Dominic; Sanjosé, Marlène; Moreau, Stéphane; Carolus, Thomas

    2018-03-01

    Noise from axial fans typically increases significantly as the tip clearance is increased. In addition to the broadband tip clearance noise at the design flow rate, narrowband humps also associated with the tip flow are observed in the far-field acoustic spectra at lower flow rate. In this study, both experimental and numerical methods are used to shed more light on the noise generation mechanism of this narrowband tip clearance noise and provide a unified description of this source. Unsteady aeroacoustic predictions with the Lattice-Boltzmann Method (LBM) are successfully compared with experiment. Such a validation allows using LBM data to conduct a detailed modal analysis of the pressure field for detecting rotating coherent flow structures which might be considered as noise sources. As previously found in ring fans the narrowband humps in the far-field noise spectra are found to be related to the tip clearance noise that is generated by an interaction of coherent flow structures present in the tip region with the leading edge of the impeller blades. The visualization of the coherent structures shows that they are indeed part of the unsteady tip clearance vortex structures. They are hidden in a complex, spatially and temporally inhomogeneous flow field, but can be recovered by means of appropriate filtering techniques. Their pressure trace corresponds to the so-called rotational instability identified in previous turbomachinery studies, which brings a unified picture of this tip-noise phenomenon for the first time.

  5. Investigation of Unsteady Tip Clearance Flow in a Low-Speed One and Half Stage Axial Compressor with LES And PIV

    Science.gov (United States)

    Hah, Chunill; Hathaway, Michael; Katz, Joseph; Tan, David

    2015-01-01

    The primary focus of this paper is to investigate how a rotor's unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor when the rotor tip gap size is increased from 0.5 mm (0.49% of rotor tip blade chord, 2% of blade span) to 2.4 mm (2.34% chord, 4% span) at the design condition are investigated. The changes in unsteady tip clearance flow with the 0.62 % tip gap as the flow rate is reduced to near stall condition are also investigated. A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at these three flow conditions. Detailed Stereoscopic PIV (SPIV) measurements of the current flow fields were also performed at the Johns Hopkins University in a refractive index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. Unsteady tip clearance flow fields from LES are compared with the PIV measurements and both LES and PIV results are used to study changes in tip clearance flow structures. The current study shows that the tip clearance vortex is not a single structure as traditionally perceived. The tip clearance vortex is formed by multiple interlaced vorticities. Therefore, the tip clearance vortex is inherently unsteady. The multiple interlaced vortices never roll up to form a single structure. When phased-averaged, the tip clearance vortex appears as a single structure. When flow rate is reduced with the same tip gap, the tip clearance vortex rolls further upstream and the tip clearance vortex moves further radially inward and away from the suction side of the blade. When the tip gap size is increased at the design flow condition, the overall tip clearance vortex becomes stronger and it stays closer to the blade suction side and the vortex core extends all the way to the exit of the blade passage. Measured and calculated unsteady flow

  6. Turbine-blade tip clearance and tip timing measurements using an optical fiber bundle sensor

    Science.gov (United States)

    Garcia, Iker; Beloki, Josu; Zubia, Joseba; Durana, Gaizka; Aldabaldetreku, Gotzon

    2013-04-01

    Traditional limitations of capacitive, inductive or discharging probe sensor for tip timing and tip clearance measurements are overcome by reflective intensity modulated optical fiber sensors. This paper presents the signals and results corresponding to a one stage turbine rig which rotor has 146 blades, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on turbine casing. It is composed of a central illuminating fiber that guides the light from a laser to the turbine blade, and two concentric rings of receiving fibers that collect the reflected light. Two photodetectors turn this reflected light signal from the receiving rings into voltage. The electrical signals are acquired and saved by a high-sample-rate oscilloscope. In tip clearance calculations the ratio of the signals provided by each ring of receiving fibers is evaluated and translated into distance. In the case of tip timing measurements, only one of the signals is considered to get the arrival time of the blade. The differences between the real and theoretical arrival times of the blades are used to obtain the deflections amplitude. The system provides the travelling wave spectrum, which presents the average vibration amplitude of the blades at a certain nodal diameter. The reliability of the results in the turbine rig testing facilities suggests the possibility of performing these measurements in real turbines under real working conditions.

  7. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems

    Science.gov (United States)

    Tomassini, R.; Rossi, G.; Brouckaert, J.-F.

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  8. Effect of tip clearance on wall shear stress of an axial LVAD

    Science.gov (United States)

    Sarath, S.; Vikas, R.

    2017-09-01

    Wall shear stress is a crucial parameter used for blood damage analysis, and typically a value of 400 Pa is set as a limit. Tip clearance is a major factor contributing to hemolysis and pump efficiency. In this study, different tip gap configurations are used to analyse the wall shear stress developed on the blade surface of a constant thickness blade design, and a varying thickness blade design using CFD analysis. It was found that, for a particular geometry, as the clearance gap reduces, flow rate over the high wall shear stress area decreases even though the high wall shear stress span is found to extend. For each design, the optimum clearance gap is iteratively attained, keeping the maximum WSS as a limiting factor. Thus a better pump designs is obtained, whose leakage flow patterns are lower than that of the initial design, hence also leading to higher pump efficiency.

  9. Turbine Engine Clearance Control Systems: Current Practices and Future Directions

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.

    2002-01-01

    Improved blade tip sealing in the high pressure compressor (HPC) and high pressure turbine (HPT) can provide dramatic reductions in specific fuel consumption (SFC), time-on-wing, compressor stall margin, and engine efficiency as well as increased payload and mission range capabilities. Maintenance costs to overhaul large commercial gas turbine engines can easily exceed $1M. Engine removal from service is primarily due to spent exhaust gas temperature (EGT) margin caused mainly by the deterioration of HPT components. Increased blade tip clearance is a major factor in hot section component degradation. As engine designs continue to push the performance envelope with fewer parts and the market drives manufacturers to increase service life, the need for advanced sealing continues to grow. A review of aero gas turbine engine HPT performance degradation and the mechanisms that promote these losses are discussed. Benefits to the HPT due to improved clearance management are identified. Past and present sealing technologies are presented along with specifications for next generation engine clearance control systems.

  10. Rate-Based Model Predictive Control of Turbofan Engine Clearance

    Science.gov (United States)

    DeCastro, Jonathan A.

    2006-01-01

    An innovative model predictive control strategy is developed for control of nonlinear aircraft propulsion systems and sub-systems. At the heart of the controller is a rate-based linear parameter-varying model that propagates the state derivatives across the prediction horizon, extending prediction fidelity to transient regimes where conventional models begin to lose validity. The new control law is applied to a demanding active clearance control application, where the objectives are to tightly regulate blade tip clearances and also anticipate and avoid detrimental blade-shroud rub occurrences by optimally maintaining a predefined minimum clearance. Simulation results verify that the rate-based controller is capable of satisfying the objectives during realistic flight scenarios where both a conventional Jacobian-based model predictive control law and an unconstrained linear-quadratic optimal controller are incapable of doing so. The controller is evaluated using a variety of different actuators, illustrating the efficacy and versatility of the control approach. It is concluded that the new strategy has promise for this and other nonlinear aerospace applications that place high importance on the attainment of control objectives during transient regimes.

  11. The influence of tip clearance on performance and internal flow condition of fluid food pump using low viscous fluid

    International Nuclear Information System (INIS)

    Kubo, S; Ishioka, T; Fukutomi, J; Shigemitsu, T

    2012-01-01

    Fluid machines for fluid food have been used in wide variety of fields i.e. transportation, the filling, and for the improvement of quality of fluid foods. However, flow conditions of it are quite complicated because fluid foods are different from water. Therefore, design methods based on internal flow conditions have not been conducted. In this research, turbo-pumps having a small number of blades were used to decrease shear loss and keep wide flow passage. The influence of the tip clearance was investigated by the numerical analysis using the model with and without the tip clearance. In this paper, the influence of tip clearance on performances and internal flow conditions of turbo-pump using low viscous fluid were clarified by experimental and numerical analysis results. In addition, design methods based on the internal flow were considered. Further, the influences of viscosity on the performance characteristic and internal flow were investigated.

  12. Investigation of the Shear Flow Effect and Tip Clearance on a Low Speed Axial Flow Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Mahesh Varpe

    2013-01-01

    Full Text Available This paper explores the effect of inlet shear flow on the tip leakage flow in an axial flow compressor cascade. A flow with a high shear rate is generated in the test section of an open circuit cascade wind tunnel by using a combination of screens with a prescribed solidity. It is observed that a stable shear flow of shear rate 1.33 is possible and has a gradual decay rate until 15 times the height of the shear flow generator downstream. The computational results obtained agree well with the available experimental data on the baseline configuration. The detailed numerical analysis shows that the tip clearance improves the blade loading near the tip through the promotion of favorable incidence by the tip leakage flow. The tip clearance shifts the centre of pressure on the blade surface towards the tip. It, however, has no effect on the distribution of end wall loss and deviation angle along the span up to 60% from the hub. In the presence of a shear inflow, the end wall effects are considerable. On the other hand, with a shear inflow, the effects of tip leakage flow are observed to be partly suppressed. The shear flow reduces the tip leakage losses substantially in terms of kinetic energy associated with it.

  13. Navier-Stokes analysis of an oxidizer turbine blade with tip clearance with and without a mini-shroud

    Science.gov (United States)

    Chan, Tony; Dejong, Frederik J.

    1993-01-01

    The Gas Generator Oxidizer Turbine (GGOT) Blade is being analyzed by various investigators under the NASA MSFC-sponsored Turbine Stage Technology Team design effort. The present work concentrates on the tip clearance region flow and associated losses; however, flow details for the passage region are also obtained in the simulations. The present calculations simulate the rotor blade row in a rotating reference frame with the appropriate coriolis and centrifugal acceleration term included in the momentum equations. The upstream computational boundary is located about one axial chord from the blade leading edge. The boundary conditions at this location have been determined by Pratt & Whitney using an Euler analysis without the vanes to obtain approximately the same flow profiles at the rotor as were obtained with the Euler stage analysis including the vanes. Inflow boundary layer profiles are then constructed assuming the skin friction coefficient at both the hub and the casing. The downstream computational boundary is located about one axial chord from the blade trailing edge, and the circumferentially averaged static pressure at this location was also obtained from the P&W Euler analysis. Results obtained for the 3-D baseline GGOT geometry at the full scale design Reynolds number show a region of high loss in the region near the casing. Particle traces in the near tip region show vortical flow behavior of the fluid which passes through the clearance region and exits at the downstream edge of the gap. In an effort to reduce clearance flow losses, the mini-shroud concept was proposed by the Pratt & Whitney design team. Calculations were performed on the GGO geometry with the mini-shroud. Results of these calculations indicate that the mini-shroud does not significantly affect the flow in the passage region, and although the tip clearance flow is different, the mini-shroud does not seem to prevent the above-mentioned vortical flow behavior. Since both flow distortion

  14. Navier-Stokes analysis of an oxidizer turbine blade with tip clearance

    Science.gov (United States)

    Gibeling, Howard J.; Sabnis, Jayant S.

    1992-01-01

    The Gas Generator Oxidizer Turbine (GGOT) Blade is being analyzed by various investigators under the NASA MSFC sponsored Turbine Stage Technology Team design effort. The present work concentrates on the tip clearance region flow and associated losses; however, flow details for the passage region are also obtained in the simulations. The present calculations simulate the rotor blade row in a rotating reference frame with the appropriate coriolis and centrifugal acceleration terms included in the momentum equation. The upstream computational boundary is located about one axial chord from the blade leading edge. The boundary conditions at this location were determined by using a Euler analysis without the vanes to obtain approximately the same flow profiles at the rotor as were obtained with the Euler stage analysis including the vanes. Inflow boundary layer profiles are then constructed assuming the skin friction coefficient at both the hub and the casing. The downstream computational boundary is located about one axial chord from the blade trailing edge, and the circumferentially averaged static pressure at this location was also obtained from the Euler analysis. Results were obtained for the 3-D baseline GGOT geometry at the full scale design Reynolds number. Details of the clearance region flow behavior and blade pressure distributions were computed. The spanwise variation in blade loading distributions are shown, and circumferentially averaged spanwise distributions of total pressure, total temperature, Mach number, and flow angle are shown at several axial stations. The spanwise variation of relative total pressure loss shows a region of high loss in the region near the casing. Particle traces in the near tip region show vortical behavior of the fluid which passes through the clearance region and exits at the downstream edge of the gap.

  15. Tip-leakage cavitation in the clearance of a 2D hydrofoil with fillets: high-speed visualization and PIV/PTV measurements

    Science.gov (United States)

    Zapryagaev, Ivan I.; Timoshevskiy, Mikhail V.; Pervunin, Konstantin S.

    2017-09-01

    Tip-clearance cavitation is one of the most aggressive forms of cavitation as it can cause surface erosion of hydraulic machinery elements and, as a result, their fatigue damage and disturb designed operating conditions. At present, the literature lacks for detailed experimental data on the inception and development of this type of cavitation at various flow conditions. In the paper, a tip-leakage cavitation occurring in the clearance between an end face of a 2D hydrofoil (a scaled-down model of guide vanes (GV) of a Francis turbine) and a transparent wall of the test section was studied. The experiments were carried out for different cavitating regimes on the cavitation number and two attack angles of 3° and 9°, with the gap size (tip clearance width) varied in the range from 0.4 to 0.8 mm. In order to determine the cavitation inception conditions and investigate the dynamics of the tip-leakage cavitation, a high-speed visualization was applied. A modified PIV/PTV technique with a diverging laser beam instead of a laser light sheet was used to measure the mean velocity distributions within the gap. It was shown that the cavitation pattern on the suction side of the GV model impacts the dynamics of the leakage flow in the gap but does not affect the sheet cavity formed close to the foil leading edge in the clearance as well as its size and dynamics. When the gap size is increased, the tip-leakage cavitation initiates at higher cavitation numbers or, in other words, conditions for the cavitation occurrence become more favorable.

  16. Local measurement and numerical modeling of mass/heat transfer from a turbine blade in a linear cascade with tip clearance

    Science.gov (United States)

    Jin, Peitong

    2000-11-01

    Local mass/heat transfer measurements from the turbine blade near-tip and the tip surfaces are performed using the naphthalene sublimation technique. The experiments are conducted in a linear cascade consisting of five high-pressure blades with a central test-blade configuration. The incoming flow conditions are close to those of the gas turbine engine environment (boundary layer displacement thickness is about 0.01 of chord) with an exit Reynolds number of 6.2 x 105. The effects of tip clearance level (0.86%--6.90% of chord), mainstream Reynolds number and turbulence intensity (0.2 and 12.0%) are investigated. Two methods of flow visualization---oil and lampblack, laser light sheet smoke wire---as well as static pressure measurement on the blade surface are used to study the tip leakage flow and vortex in the cascade. In addition, numerical modeling of the flow and heat transfer processes in the linear cascade with different tip clearances is conducted using commercial software incorporating advanced turbulence models. The present study confirms many important results on the tip leakage flow and vortex from the literature, contributes to the current understanding in the effects of tip leakage flow and vortex on local heat transfer from the blade near-tip and the tip surfaces, and provides detailed local and average heat/mass transfer data applicable to turbine blade tip cooling design.

  17. Techniques for blade tip clearance measurements with capacitive probes

    Science.gov (United States)

    Steiner, Alexander

    2000-07-01

    This article presents a proven but advantageous concept for blade tip clearance evaluation in turbomachinery. The system is based on heavy duty probes and a high frequency (HF) and amplifying electronic unit followed by a signal processing unit. Measurements are taken under high temperature and other severe conditions such as ionization. Every single blade can be observed. The signals are digitally filtered and linearized in real time. The electronic set-up is highly integrated. Miniaturized versions of the electronic units exist. The small and robust units can be used in turbo engines in flight. With several probes at different angles in one radial plane further information is available. Shaft eccentricity or blade oscillations can be calculated.

  18. Distributed collaborative probabilistic design for turbine blade-tip radial running clearance using support vector machine of regression

    Science.gov (United States)

    Fei, Cheng-Wei; Bai, Guang-Chen

    2014-12-01

    To improve the computational precision and efficiency of probabilistic design for mechanical dynamic assembly like the blade-tip radial running clearance (BTRRC) of gas turbine, a distribution collaborative probabilistic design method-based support vector machine of regression (SR)(called as DCSRM) is proposed by integrating distribution collaborative response surface method and support vector machine regression model. The mathematical model of DCSRM is established and the probabilistic design idea of DCSRM is introduced. The dynamic assembly probabilistic design of aeroengine high-pressure turbine (HPT) BTRRC is accomplished to verify the proposed DCSRM. The analysis results reveal that the optimal static blade-tip clearance of HPT is gained for designing BTRRC, and improving the performance and reliability of aeroengine. The comparison of methods shows that the DCSRM has high computational accuracy and high computational efficiency in BTRRC probabilistic analysis. The present research offers an effective way for the reliability design of mechanical dynamic assembly and enriches mechanical reliability theory and method.

  19. Study of the capacitance technique for measuring high-temperature blade tip clearance on ceramic rotors

    Science.gov (United States)

    Barranger, John P.

    1993-01-01

    Higher operating temperatures required for increased engine efficiency can be achieved by using ceramic materials for engine components. Ceramic turbine rotors are subject to the same limitations with regard to gas path efficiency as their superalloy predecessors. In this study, a modified frequency-modulation system is proposed for the measurement of blade tip clearance on ceramic rotors. It is expected to operate up to 1370 C (2500 F), the working temperature of present engines with ceramic turbine rotors. The design of the system addresses two special problems associated with nonmetallic blades: the capacitance is less than that of a metal blade and the effects of temperature may introduce uncertainty with regard to the blade tip material composition. To increase capacitance and stabilize the measurement, a small portion of the rotor is modified by the application of 5-micron-thick platinum films. The platinum surfaces on the probe electrodes and rotor that are exposed to the high-velocity gas stream are coated with an additional 10-micron-thick protective ceramic topcoat. A finite-element method is applied to calculate the capacitance as a function of clearance.

  20. An Experimental Investigation of the Flow Physics Associated With End Wall Losses and Large Rotor Tip Clearances as Found in the Rear Stages of a High Pressure Compressor

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2015-01-01

    The focus of this work was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearance heights were studied with nominal tip clearance heights of 1.5%, 3.0%, and 4.0% based on a constant annulus height. Overall compressor performance was investigated at four corrected speedlines (100%, 90%, 80%, and 68%) for each of the three tip clearance configurations using total pressure and total temperature rakes distributed throughout the compressor. The results have confirmed results from previous authors showing a decrease of total pressure rise, isentropic efficiency, and stall margin which is approximately linear with increasing tip clearance height. The stall inception mechanisms have also been evaluated at the same corrected speeds for each of the tip clearance configurations. Detailed flow field measurements have been collected at two loading conditions, nominal loading (NL) and high loading (HL), on the 100% corrected speedline for the smallest and largest tip clearance heights (1.5% and 4.0%). Steady detailed radial traverses of total pressure at the exit of each stator row have been supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data have helped to quantify the size of the leakage flow at the exit of each rotor. Thermal anemometry has also been implemented to evaluate the time-resolved three-dimensional components of velocity throughout the compressor and calculate blockage due to the rotor tip leakage flow throughout the compressor. These

  1. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  3. A Blade Tip Timing Method Based on a Microwave Sensor

    Directory of Open Access Journals (Sweden)

    Jilong Zhang

    2017-05-01

    Full Text Available Blade tip timing is an effective method for blade vibration measurements in turbomachinery. This method is increasing in popularity because it is non-intrusive and has several advantages over the conventional strain gauge method. Different kinds of sensors have been developed for blade tip timing, including optical, eddy current and capacitance sensors. However, these sensors are unsuitable in environments with contaminants or high temperatures. Microwave sensors offer a promising potential solution to overcome these limitations. In this article, a microwave sensor-based blade tip timing measurement system is proposed. A patch antenna probe is used to transmit and receive the microwave signals. The signal model and process method is analyzed. Zero intermediate frequency structure is employed to maintain timing accuracy and dynamic performance, and the received signal can also be used to measure tip clearance. The timing method uses the rising and falling edges of the signal and an auto-gain control circuit to reduce the effect of tip clearance change. To validate the accuracy of the system, it is compared experimentally with a fiber optic tip timing system. The results show that the microwave tip timing system achieves good accuracy.

  4. Entropy generation and optimization of laminar convective heat transfer and fluid flow in a microchannel with staggered arrays of pin fin structure with tip clearance

    International Nuclear Information System (INIS)

    Shi, Zhongyuan; Dong, Tao

    2015-01-01

    Highlights: • Entropy generation from heat transfer and flow friction are investigated synthetically. • The impact of correlated variables, dimensionless tip clearance, aspect ratio and Reynolds number, are discussed. • Physical interpretation of the result from multiobjective entropy generation minimization is presented. - Abstract: Entropy generation rate accounting for heat transfer and flow friction is presented for the flow in microchannel with staggered pin fin arrays, clearance existing between the pin fin tip and the shroud plate. Within the scope of the present work, entropy generation rate due to heat transfer is levels of magnitude higher than that from flow friction, which is nonetheless not negligible considering its scaling effect on the pumping power consumption, for all cases under investigation. For the pin fin structure with high aspect ratio (height-to-diameter), the effect of tip clearance was found more pronounced with a conductive nature competing with the convective. When this ratio is low, the convective effect dominates the variation of entropy generation by heat transfer and flow friction, the effect of the clearance gap favored by higher aspect ratio. The entropy minimization method is applied to seek for an optimal combination of all impact factors under investigation. The Pareto frontier along with its corresponding solution sets are obtained by Multiobjective Optimization Genetic Algorithm. The solution sets acquired for the scenario with high-aspect-ratio pin fin fall within the region of lower pin fin density where the trade off between the convective and the conductive effects is identified. On the other hand, dominated by the convective nature, the solution sets for cases with lower aspect ratio are in principle located at the upper bounds

  5. Numerical and Experimental Investigations of Steady Micro-Tip Injection on a Subsonic Axial-Flow Compressor Rotor

    Directory of Open Access Journals (Sweden)

    Xingen Lu

    2006-01-01

    tip-clearance flow manipulation. The repositioning of the tip-clearance vortex further towards the trailing edge of the blade passage and delaying the movement of incoming/tip-clearance flow interface to the leading edge plane are the physical mechanisms responsible for extending the compressor stall margin.

  6. Numerical analysis of turbine blade tip treatments

    Science.gov (United States)

    Gopalaswamy, Nath S.; Whitaker, Kevin W.

    1992-01-01

    Three-dimensional solutions of the Navier-Stokes equations for a turbine blade with a turning angle of 180 degrees have been computed, including blade tip treatments involving cavities. The geometry approximates a preliminary design for the GGOT (Generic Gas Oxidizer Turbine). The data presented here will be compared with experimental data to be obtained from a linear cascade using original GGOT blades. Results have been computed for a blade with 1 percent clearance, based on chord, and three different cavity sizes. All tests were conducted at a Reynolds number of 4 x 10 exp 7. The grid contains 39,440 points with 10 spanwise planes in the tip clearance region of 5.008E-04 m. Streamline plots and velocity vectors together with velocity divergence plots reveal the general flow behavior in the clearance region. Blade tip temperature calculations suggest placement of a cavity close to the upstream side of the blade tip for reduction of overall blade tip temperature. The solutions do not account for the relative motion between the endwall and the turbine blade. The solutions obtained are generally consistent with previous work done in this area,

  7. Optical Tip Clearance Measurements as a Tool for Rotating Disk Characterization

    Directory of Open Access Journals (Sweden)

    Iker García

    2017-01-01

    Full Text Available An experimental investigation on the vibrational behavior of a rotating disk by means of three optical fiber sensors is presented. The disk, which is a scale model of the real disk of an aircraft engine, was assembled in a wind tunnel in order to simulate real operation conditions. The pressure difference between the upstream and downstream sides of the disk causes an airflow that might force the disk to vibrate. To characterize this vibration, a set of parameters was determined by measuring the tip clearance of the disk: the amplitude, the frequency and the number of nodal diameters in the disk. All this information allowed the design of an upgraded prototype of the disk, whose performance was also characterized by the same method. An optical system was employed for the measurements, in combination with a strain gauge mounted on the disk surface, which served to confirm the results obtained. The data of the strain gauge coincided closely with those provided by the optical fiber sensors, thus demonstrating the suitability of this innovative technique to evaluate the vibrational behavior of rotating disks.

  8. Experimental and numerical investigation on compressor cascade flows with tip clearance at a low Reynolds number condition

    Science.gov (United States)

    Kato, Hiromasa; Taniguchi, Hideo; Matsuda, Kazunari; Funazaki, Ken-Ichi; Kato, Dai; Pallot, Guillaume

    2011-12-01

    High flow rate aeroengines typically employ axial flow compressors, where aerodynamic loss is predominantly due to secondary flow features such as tip leakage and corner vortices. In very high altitude missions, turbomachinery operates at low density ambient atmosphere, and the recent trend toward more compact engine core inevitably leads to the reduction of blade size, which in turn increases the relative height of the blade tip clearance. Low Reynolds number flowfield as a result of these two factors amplifies the relative importance of secondary flow effects. This paper focuses on the behavior of tip leakage flow, investigating by use of both experimental and numerical approaches. In order to understand the complex secondary flow behavior, cascade tests are usually conducted using intrusive probes to determine the loss. However relatively few experimental studies are published on tip leakage flows which take into account the interaction between a rotating blade row and its casing wall. Hence a new linear cascade facility has been designed with a moving belt casing in order to reproduce more realistic flowfield as encountered by a rotating compressor row. Numerical simulations were also performed to aid in the understanding of the complex flow features. The experimental results indicate a significant difference in the flowfield when the moving belt casing is present. The numerical simulations reveal that the leakage vortex is pulled by the shearing motion of the endwall toward the pressure side of the adjacent blade. The results highlight the importance of casing wall relative motion in analyzing leakage flow effects.

  9. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast To learn more about how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist ...

  11. Tip-Clearance Measurement in the First Stage of the Compressor of an Aircraft Engine

    Directory of Open Access Journals (Sweden)

    Iker García

    2016-11-01

    Full Text Available In this article, we report the design of a reflective intensity-modulated optical fiber sensor for blade tip-clearance measurement, and the experimental results for the first stage of a compressor of an aircraft engine operating in real conditions. The tests were performed in a ground test cell, where the engine completed four cycles from idling state to takeoff and back to idling state. During these tests, the rotational speed of the compressor ranged between 7000 and 15,600 rpm. The main component of the sensor is a tetrafurcated bundle of optical fibers, with which the resulting precision of the experimental measurements was 12 µm for a measurement range from 2 to 4 mm. To get this precision the effect of temperature on the optoelectronic components of the sensor was compensated by calibrating the sensor in a climate chamber. A custom-designed MATLAB program was employed to simulate the behavior of the sensor prior to its manufacture.

  12. An Experimental Characterization of Tip Leakage Flows and Corresponding Effects on Multistage Compressor Performance

    Science.gov (United States)

    Berdanier, Reid Adam

    The effect of rotor tip clearances in turbomachinery applications has been a primary research interest for nearly 80 years. Over that time, studies have shown increased tip clearance in axial flow compressors typically has a detrimental effect on overall pressure rise capability, isentropic efficiency, and stall margin. With modern engine designs trending toward decreased core sizes to increase propulsive efficiency (by increasing bypass ratio) or additional compression stages to increase thermal efficiency by increasing the overall pressure ratio, blade heights in the rear stages of the high pressure compressor are expected to decrease. These rear stages typically feature smaller blade aspect ratios, for which endwall flows are more important, and the rotor tip clearance height represents a larger fraction of blade span. As a result, data sets collected with large relative rotor tip clearance heights are necessary to facilitate these future small core design goals. This research seeks to characterize rotor tip leakage flows for three tip clearance heights in the Purdue three-stage axial compressor facility (1.5%, 3.0%, and 4.0% as a percentage of overall annulus height). The multistage environment of this compressor provides the unique opportunity to examine tip leakage flow effects due to stage matching, stator-rotor interactions, and rotor-rotor interactions. The important tip leakage flow effects which develop as a result of these interactions are absent for previous studies which have been conducted using single-stage machines or isolated rotors. A series of compressor performance maps comprise points at four corrected speeds for each of the three rotor tip clearance heights. Steady total pressure and total temperature measurements highlight the effects of tip leakage flows on radial profiles and wake shapes throughout the compressor. These data also evaluate tip clearance effects on efficiency, stall margin, and peak pressure rise capability. An emphasis of

  13. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    Science.gov (United States)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  14. Tip off the HAT- Epigenetic control of learning and memory by Drosophila Tip60.

    Science.gov (United States)

    Xu, Songjun; Elefant, Felice

    2015-01-01

    Disruption of epigenetic gene control mechanisms involving histone acetylation in the brain causes cognitive impairment, a debilitating hallmark of most neurodegenerative disorders. Histone acetylation regulates cognitive gene expression via chromatin packaging control in neurons. Unfortunately, the histone acetyltransferases (HATs) that generate such neural epigenetic signatures and their mechanisms of action remain unclear. Our recent findings provide insight into this question by demonstrating that Tip60 HAT action is critical for morphology and function of the mushroom body (MB), the learning and memory center in the Drosophila brain. We show that Tip60 is robustly produced in MB Kenyon cells and extending axonal lobes and that targeted MB Tip60 HAT loss results in axonal outgrowth disruption. Functional consequences of loss and gain of Tip60 HAT levels in the MB are evidenced by defects in memory. Tip60 ChIP-Seq analysis reveals enrichment for genes that function in cognitive processes and accordingly, key genes representing these pathways are misregulated in the Tip60 HAT mutant fly brain. Remarkably, increasing levels of Tip60 in the MB rescues learning and memory deficits resulting from Alzheimer's disease associated amyloid precursor protein (APP) induced neurodegeneration. Our studies highlight the potential of HAT activators as a therapeutic option for cognitive disorders.

  15. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  16. Effect of tip clearance on performance of small axial hydraulic turbine

    Science.gov (United States)

    Boynton, J. L.; Rohlik, H. E.

    1976-01-01

    The first two stages of a six stage liquid oxygen turbine were tested in water. One and two stage performance was determined for one shrouded and two unshrouded blade end configurations over ranges of clearance and blade-jet speed ratio. First stage, two stage, and second stage efficiencies are included as well as the effect of clearance on mass flow for two stage operation.

  17. Clearance and release from control - An international perspective

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    This paper tries to give an overview of the clearance, or release from regulatory control, on an international scale, including some of those countries where clearance has become or is about to become vital for D and D. The emphasis lies on the impact of clearance, and in particular of differences between clearance levels of various countries, on D and D. Relevance of clearance for D and D of nuclear installations Clearance is an essential part of waste management (or more general, material management) in nuclear installations, and in particular during the decommissioning phase where waste streams continues to arise. Of course, the relevance of clearance in a particular country depends on a number of factors, like: availability of a final repository and its price; prevailing decommissioning strategy; number of nuclear installations reaching decommissioning phase. This small selection of reasons why clearance may be of varying importance for different countries may already suffice to illustrate why up to now clearance has been developed and implemented in quite different ways. If one thinks of additional reasons that may influence clearance, like politics, the public opinion, availability of funds etc., the situation becomes even more complex. It is, however safe to draw the conclusion that countries with a certain number of nuclear installations which have been or will soon be shut down or which are already in the decommissioning phase will need to implement provisions for clearance. This has indeed been the case with countries like the UK, Germany, the USA, Sweden, and a number of others. It is not essential for clearance levels to be exactly equal between various countries. They may differ as long as the difference is not too large, e.g. the values fall into the same order of magnitude. This is the reason why for example Germany has no problems with clearance levels which differ from the EU recommendation RP 122 partially adopted in a number of EU countries

  18. Numerical simulation of the tip clearance flow in axial turbomachinery; Numerische Simulation der Stroemung im radialen Schaufelspalt axialer Turbomaschinen

    Energy Technology Data Exchange (ETDEWEB)

    Melake, A [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e.V. (DLR), Koeln (Germany). Inst. fuer Antriebstechnik

    1997-12-31

    A computer program has been developed to calculate the three-dimensional tip leakage flow in axial turbomachinery based on the Navier-Stokes equation. This program has been applied to investigate the leakage flow within the gap between the blade fip and casing in an annular compressor cascade. A block structured computational mesh has been used in order to resolve the flow details within the gap and the passage flow. Flow characteristics like boundary layer separation, vortex genesis and interaction of the leakage flow with the secondary flow have been investigated and compared with existing experimental data. By varying the incidence angle and the tip gap the above mentioned flow phenomena have been analysed in an annular compressor cascade and a shrouded propfan rotor respectively. Furthermore, the relationship between the total pressure loss, the axial velocity deficit and the divergence of the tip leakage vortex has been investigated. Streamlines, limited streamlines and the critical point theory have been used extensively to analyse the boundary layer separation on the casing and its roll up to form the tip clearance vortex. (orig.). 59 figs., 3 tabs., 110 refs. [Deutsch] Es wurde ein Rechenprogramm zur Berechnung der dreidimensionalen Spaltstroemung im radialen Schaufelspalt axialer Turbomaschinen auf der Basis der Navier-Stokes`schen Gleichungen entwickelt und angewendet. Um die Stroemung innerhalb des Spaltes und der Schaufelpassage besser aufloesen zu koennen, wurde eine blockstrukturierte Netztopologie verwendet. Stroemungseigenschaften wie Grenzschichtabloesung, Entstehung des Spaltwirbels, Interaktion der Spaltstroemung mit der Sekundaerstroemung werden untersucht und mit vorhandenen experimentellen Daten verglichen. Im weiteren werden durch Variation der Inzidenz und der Spaltweite die oben genannten Stroemungsphaenomene an einem axialen Verdichterringgitter und an einem ummantelten Propfan analysiert. Ferner werden die Korrelation zwischen

  19. Novel sensors to enable closed-loop active clearance control in gas turbine engines

    Science.gov (United States)

    Geisheimer, Jonathan; Holst, Tom

    2014-06-01

    Active clearance control within the turbine section of gas turbine engines presents and opportunity within aerospace and industrial applications to improve operating efficiencies and the life of downstream components. Open loop clearance control is currently employed during the development of all new large core aerospace engines; however, the ability to measure the gap between the blades and the case and close down the clearance further presents as opportunity to gain even greater efficiencies. The turbine area is one of the harshest environments for long term placement of a sensor in addition to the extreme accuracy requirements required to enable closed loop clearance control. This paper gives an overview of the challenges of clearance measurements within the turbine as well as discusses the latest developments of a microwave sensor designed for this application.

  20. An investigation of rotor tip leakage flows in the rear-block of a multistage compressor

    Science.gov (United States)

    Brossman, John Richard

    An effective method to improve gas turbine propulsive efficiency is to increase the bypass ratio. With fan diameter reaching a practical limit, increases in bypass ratio can be obtained from reduced core engine size. Decreasing the engine core, results in small, high pressure compressor blading, and large relative tip clearances. At general rule of 1% reduction in compressor efficiency with a 1% increase in tip clearance, a 0.66% change in SFC indicates the entire engine is sensitive to high pressure compressor tip leakage flows. Therefore, further investigations and understanding of the rotor tip leakage flows can help to improve gas turbine engine efficiency. The objectives of this research were to investigate tip leakage flows through computational modeling, examine the baseline experimental steady-stage performance, and acquire unsteady static pressure, over-the rotor to observe the tip leakage flow structure. While tip leakage flows have been investigated in the past, there have been no facilities capable of matching engine representative Reynolds number and Mach number while maintaining blade row interactions, presenting a unique and original flow field to investigate at the Purdue 3-stage axial compressor facility. To aid the design of experimental hardware and determine the influence of clearance geometry on compressor performance, a computational model of the Purdue 3-stage compressor was investigated using a steady RANS CFD analysis. A cropped rotor and casing recess design was investigated to increase the rotor tip clearance. While there were small performance differences between the geometries, the tip leakage flow field was found independent of the design therefore designing future experimental hardware around a casing recess is valid. The largest clearance with flow margin past the design point was 4% tip clearance based on the computational model. The Purdue 3-stage axial compressor facility was rebuilt and setup for high quality, detailed flow

  1. Effect of Guide Vane Clearance Gap on Francis Turbine Performance

    Directory of Open Access Journals (Sweden)

    Ravi Koirala

    2016-04-01

    Full Text Available Francis turbine guide vanes have pivoted support with external control mechanism, for conversion of pressure to kinetic energy and to direct them to runner vanes. This movement along the support is dependent on variation of load and flow (operating conditions. Small clearance gaps between facing plates and the upper and lower guide vane tips are available to aid this movement, through which leakage flow occurs. This secondary flow disturbs the main flow stream, resulting performance loss. Additionally, these increased horseshoe vortex, in presence of sand, when crosses through the gaps, both the surfaces are eroded. This causes further serious effect on performance and structural property by increasing gaps. This paper discusses the observation of the severity in hydropower plants and effect of clearance gaps on general performance of the Francis turbine through computational methods. It also relates the primary result with the empirical relation for leakage flow prediction. Additionally, a possible method to computationally estimate thickness depletion has also been presented. With increasing clearance gap, leakage increases, which lowers energy conversion and turbine efficiency along with larger secondary vortex.

  2. Optimization Based Clearance of Flight Control Laws A Civil Aircraft Application

    CERN Document Server

    Hansson, Anders; Puyou, Guilhem

    2012-01-01

    This book summarizes the main achievements of the EC funded 6th Framework Program project COFCLUO – Clearance of Flight Control Laws Using Optimization. This project successfully contributed to the achievement of a top-level objective to meet society’s needs for a more efficient, safer and environmentally friendly air transport by providing new techniques and tools for the clearance of flight control laws. This is an important part of the certification and qualification process of an aircraft – a costly and time-consuming process for the aeronautical industry.   The overall objective of the COFCLUO project was to develop and apply optimization techniques to the clearance of flight control laws in order to improve efficiency and reliability. In the book, the new techniques are explained and benchmarked against traditional techniques currently used by the industry. The new techniques build on mathematical criteria derived from the certification and qualification requirements together with suitable models...

  3. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  4. Studi Karakteristik Aliran Tiga Dimensi Dan Perpindahan Panas Pada Cascade Airfoil Dengan Pengaruh Clearance

    Directory of Open Access Journals (Sweden)

    Yusuf Wibisono

    2013-03-01

    Full Text Available Dalam dunia teknik khususunya mekanika fluida, aliran tiga dimensi merupakan hal yang sangat penting guna untuk mengetahui fenomena aliran dan perpindahan panas yang terjadi pada bluffbody cascade airfoil. Error atau loses yang terjadi pada cascade airfoil disebabkan oleh adanya aliran sekunder. Error atau loses tersebut menurut penilitian yang terlah dilakukan dapat dikurang dengan aspek clearance. Tujuan dari penilitian ini adalah untuk menganalisa karaktersistik aliran tiga dimensi serta perpindahan panas akibat adanya perubahan jarak antara leading edge antara cascade dan sudut serang serta bentuk geometri. hasil dari simulasi divisualisasikan dalam bentuk velocity dan pressure coefficient. Pada cascade airfoil dengan sudut serang 20° terjadi fenomena pada dinding clearance yaitu tip clearance flow di mana ketika aliran udara melewati dinding akan mengalami up stream yang mengakibatkan arah aliran menuju ke atas, sedangkan pada dinding airfoil ditemukan aliran sekunder berupa curl flow yang akhirnya membentuk spiral point pada trailing edge. Perubahan sudut serang menjadi -20° membuat perbedaan tekanan antara lower side dan upper side semakin lemah, begitu juga tip clearance flow yang terjadi pada wall clearance mengalami perubahan arah menjadi down stream yang mengakibatkan arah aliran menjuu kebawah. Perubahan sudut juga berpengaruh terhadap pressure coeficient pada boundary layer airfoil dan mengakibatkan blockage effect serta terjadinya vortex yang berbeda.

  5. An intelligent control scheme for precise tip-motion control in atomic force microscopy.

    Science.gov (United States)

    Wang, Yanyan; Hu, Xiaodong; Xu, Linyan

    2016-01-01

    The paper proposes a new intelligent control method to precisely control the tip motion of the atomic force microscopy (AFM). The tip moves up and down at a high rate along the z direction during scanning, requiring the utilization of a rapid feedback controller. The standard proportional-integral (PI) feedback controller is commonly used in commercial AFMs to enable topography measurements. The controller's response performance is determined by the set of the proportional (P) parameter and the integral (I) parameter. However, the two parameters cannot be automatically altered simultaneously according to the scanning speed and the surface topography during continuors scanning, leading to an inaccurate measurement. Thus a new intelligent controller combining the fuzzy controller and the PI controller is put forward in the paper. The new controller automatically selects the most appropriate PI parameters to achieve a fast response rate on basis of the tracking errors. In the experimental setup, the new controller is realized with a digital signal process (DSP) system, implemented in a conventional AFM system. Experiments are carried out by comparing the new method with the standard PI controller. The results demonstrate that the new method is more robust and effective for the precise tip motion control, corresponding to the achievement of a highly qualified image by shortening the response time of the controller. © Wiley Periodicals, Inc.

  6. Clearance of slightly radioactive material from radiological control in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    1995-01-01

    Clearance from radiological control of slightly radioactive material arising from operation or decommissioning of nuclear installations has been practiced in Germany for nearly two decades. Meanwhile, for the clearance of metal generally approved and applicable recommendations for clearance levels have been issued. For other materials like building waste, case-by-case decisions are made by the state licensing authorities. Efforts to implement consistent sets of clearance levels for all kinds of material are under way. As several decommissioning projects will soon generate large amounts of materials from dismantling, a solution needs to be reached soon. The legal framework in Germany governing the use of atomic energy consists of the Atomic Energy Act and several ordinances. Rules and guidelines including the recommendations of the German Commission for Radiation Protection (SSK) exist on a lower level and are not legally binding. Several generic studies for the derivation of clearance levels for metals and building debris with alpha, beta, and gamma contamination have been performed on behalf of the Federal Ministry for Environment, Nature Conservation and Nuclear Safety, which oriented themselves on an individual dose of 10 microSv/a in agreement with IAEA recommendations. Stochastic models have been used for establishing the connection between specific activity of the material to be released and the resulting individual doses, with significant advantages over deterministic scenarios. In the future, for new SSK recommendations or an ordinance on clearance, the increase of masses from demolition of installations, higher recycling rates in the conventional sector and harmonization with international regulations and standards have to be taken into account

  7. Kaplan turbine tip vortex cavitation - analysis and prevention

    Science.gov (United States)

    Motycak, L.; Skotak, A.; Kupcik, R.

    2012-11-01

    The work is focused on one type of Kaplan turbine runner cavitation - a tip vortex cavitation. For detailed description of the tip vortex, the CFD analysis is used. On the basis of this analysis it is possible to estimate the intensity of cavitating vortex core, danger of possible blade surface and runner chamber cavitation pitting. In the paper, the ways how to avoid the pitting effect of the tip vortex are described. In order to prevent the blade surface against pitting, the following possibilities as the change of geometry of the runner blade, dimension of tip clearance and finally the installation of the anti-cavitation lips are discussed. The knowledge of the shape and intensity of the tip vortex helps to design the anti-cavitation lips more sophistically. After all, the results of the model tests of the Kaplan runner with or without anti-cavitation lips and the results of the CFD analysis are compared.

  8. Heat Transfer Characteristics on the Squealer Tip of gas turbine blade in a linear cascade

    International Nuclear Information System (INIS)

    Lee, Woo Jin; Lee, Dong Hyun; Kim, Kyung Min; Cho, Hyung Hee; Lee, Dong Ho; Kang, Shin Hyoung

    2007-01-01

    The present study investigates local heat/mass transfer characteristics on blade tip surfaces with squealer rim in a linear cascade. A cascade experiment setup consists of three airfoils. The airfoil has variable tip clearance(1, 2, 3% of axial chord length) and rim height(3, 6, 9% of axial chord length). Main flow Reynolds number based on axial chord is 1.5 x 10 5 . The axial chord length and turning angle is 237mm and 126 .deg. respectively. Naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. The results show that as the tip clearance increases, high heat transfer region moves from upstream to downstream. Also, as the rim height increases, high heat transfer region tends to move toward the suction side

  9. Investigation of axial power gradients near a control rod tip

    Energy Technology Data Exchange (ETDEWEB)

    Loberg, John, E-mail: John.Loberg@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Osterlund, Michael, E-mail: Michael.Osterlund@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Bejmer, Klaes-Hakan, E-mail: Klaes-Hakan.Bejmer@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Blomgren, Jan, E-mail: Jan.Blomgren@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Kierkegaard, Jesper, E-mail: Jesper.Kierkegaar@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden)

    2011-07-15

    Highlights: > Pin power gradients near BWR control rod tips have been investigated. > A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. > Small nodes increases pin power gradients; standard nodes underestimates gradients. > The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, {approx}15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  10. Investigation of axial power gradients near a control rod tip

    International Nuclear Information System (INIS)

    Loberg, John; Osterlund, Michael; Bejmer, Klaes-Hakan; Blomgren, Jan; Kierkegaard, Jesper

    2011-01-01

    Highlights: → Pin power gradients near BWR control rod tips have been investigated. → A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. → Small nodes increases pin power gradients; standard nodes underestimates gradients. → The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, ∼15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  11. Low power femtosecond tip-based nanofabrication with advanced control

    Science.gov (United States)

    Liu, Jiangbo; Guo, Zhixiong; Zou, Qingze

    2018-02-01

    In this paper, we propose an approach to enable the use of low power femtosecond laser in tip-based nanofabrication (TBN) without thermal damage. One major challenge in laser-assisted TBN is in maintaining precision control of the tip-surface positioning throughout the fabrication process. An advanced iterative learning control technique is exploited to overcome this challenge in achieving high-quality patterning of arbitrary shape on a metal surface. The experimental results are analyzed to understand the ablation mechanism involved. Specifically, the near-field radiation enhancement is examined via the surface-enhanced Raman scattering effect, and it was revealed the near-field enhanced plasma-mediated ablation. Moreover, silicon nitride tip is utilized to alleviate the adverse thermal damage. Experiment results including line patterns fabricated under different writing speeds and an "R" pattern are presented. The fabrication quality with regard to the line width, depth, and uniformity is characterized to demonstrate the efficacy of the proposed approach.

  12. Investigation of Turbulent Tip Leakage Vortex in an Axial Water Jet Pump with Large Eddy Simulation

    Science.gov (United States)

    Hah, Chunill; Katz, Joseph

    2012-01-01

    Detailed steady and unsteady numerical studies were performed to investigate tip clearance flow in an axial water jet pump. The primary objective is to understand physics of unsteady tip clearance flow, unsteady tip leakage vortex, and cavitation inception in an axial water jet pump. Steady pressure field and resulting steady tip leakage vortex from a steady flow analysis do not seem to explain measured cavitation inception correctly. The measured flow field near the tip is unsteady and measured cavitation inception is highly transient. Flow visualization with cavitation bubbles shows that the leakage vortex is oscillating significantly and many intermittent vortex ropes are present between the suction side of the blade and the tip leakage core vortex. Although the flow field is highly transient, the overall flow structure is stable and a characteristic frequency seems to exist. To capture relevant flow physics as much as possible, a Reynolds-averaged Navier-Stokes (RANS) calculation and a Large Eddy Simulation (LES) were applied for the current investigation. The present study reveals that several vortices from the tip leakage vortex system cross the tip gap of the adjacent blade periodically. Sudden changes in local pressure field inside tip gap due to these vortices create vortex ropes. The instantaneous pressure filed inside the tip gap is drastically different from that of the steady flow simulation. Unsteady flow simulation which can calculate unsteady vortex motion is necessary to calculate cavitation inception accurately even at design flow condition in such a water jet pump.

  13. Kaplan turbine tip vortex cavitation – analysis and prevention

    International Nuclear Information System (INIS)

    Motycak, L; Skotak, A; Kupcik, R

    2012-01-01

    The work is focused on one type of Kaplan turbine runner cavitation – a tip vortex cavitation. For detailed description of the tip vortex, the CFD analysis is used. On the basis of this analysis it is possible to estimate the intensity of cavitating vortex core, danger of possible blade surface and runner chamber cavitation pitting. In the paper, the ways how to avoid the pitting effect of the tip vortex are described. In order to prevent the blade surface against pitting, the following possibilities as the change of geometry of the runner blade, dimension of tip clearance and finally the installation of the anti-cavitation lips are discussed. The knowledge of the shape and intensity of the tip vortex helps to design the anti-cavitation lips more sophistically. After all, the results of the model tests of the Kaplan runner with or without anti-cavitation lips and the results of the CFD analysis are compared.

  14. Two-step controllable electrochemical etching of tungsten scanning probe microscopy tips

    KAUST Repository

    Khan, Yasser; Al-Falih, Hisham; Ng, Tien Khee; Ooi, Boon S.; Zhang, Yaping

    2012-01-01

    Dynamic electrochemical etching technique is optimized to produce tungsten tips with controllable shape and radius of curvature of less than 10 nm. Nascent features such as dynamic electrochemical etching and reverse biasing after drop-off are utilized, and two-step dynamic electrochemical etching is introduced to produce extremely sharp tips with controllable aspect ratio. Electronic current shut-off time for conventional dc drop-off technique is reduced to ?36 ns using high speed analog electronics. Undesirable variability in tip shape, which is innate to static dc electrochemical etching, is mitigated with novel dynamic electrochemical etching. Overall, we present a facile and robust approach, whereby using a novel etchant level adjustment mechanism, 30° variability in cone angle and 1.5 mm controllability in cone length were achieved, while routinely producing ultra-sharp probes. © 2012 American Institute of Physics.

  15. Visualized Multiprobe Electrical Impedance Measurements with STM Tips Using Shear Force Feedback Control

    Directory of Open Access Journals (Sweden)

    Luis Botaya

    2016-05-01

    Full Text Available Here we devise a multiprobe electrical measurement system based on quartz tuning forks (QTFs and metallic tips capable of having full 3D control over the position of the probes. The system is based on the use of bent tungsten tips that are placed in mechanical contact (glue-free solution with a QTF sensor. Shear forces acting in the probe are measured to control the tip-sample distance in the Z direction. Moreover, the tilting of the tip allows the visualization of the experiment under the optical microscope, allowing the coordination of the probes in X and Y directions. Meanwhile, the metallic tips are connected to a current–voltage amplifier circuit to measure the currents and thus the impedance of the studied samples. We discuss here the different aspects that must be addressed when conducting these multiprobe experiments, such as the amplitude of oscillation, shear force distance control, and wire tilting. Different results obtained in the measurement of calibration samples and microparticles are presented. They demonstrate the feasibility of the system to measure the impedance of the samples with a full 3D control on the position of the nanotips.

  16. Planar rigid-flexible coupling spacecraft modeling and control considering solar array deployment and joint clearance

    Science.gov (United States)

    Li, Yuanyuan; Wang, Zilu; Wang, Cong; Huang, Wenhu

    2018-01-01

    Based on Nodal Coordinate Formulation (NCF) and Absolute Nodal Coordinate Formulation (ANCF), this paper establishes rigid-flexible coupling dynamic model of the spacecraft with large deployable solar arrays and multiple clearance joints to analyze and control the satellite attitude under deployment disturbance. Considering torque spring, close cable loop (CCL) configuration and latch mechanisms, a typical spacecraft composed of a rigid main-body described by NCF and two flexible panels described by ANCF is used as a demonstration case. Nonlinear contact force model and modified Coulomb friction model are selected to establish normal contact force and tangential friction model, respectively. Generalized elastic force are derived and all generalized forces are defined in the NCF-ANCF frame. The Newmark-β method is used to solve system equations of motion. The availability and superiority of the proposed model is verified through comparing with numerical co-simulations of Patran and ADAMS software. The numerical results reveal the effects of panel flexibility, joint clearance and their coupling on satellite attitude. The effects of clearance number, clearance size and clearance stiffness on satellite attitude are investigated. Furthermore, a proportional-differential (PD) attitude controller of spacecraft is designed to discuss the effect of attitude control on the dynamic responses of the whole system.

  17. Design of characteristic parameters for controlling tungsten tip profile during electrochemical etching

    Energy Technology Data Exchange (ETDEWEB)

    Le Duy Cuong; Duong, Thanh Hung; Kim, Huyn Chul [Inje University, Gimhae (Korea, Republic of)

    2014-05-15

    Micro/nano-scale tungsten tips fabricated by electrochemical etching have many diverse industrial applications. The characteristic parameters of the tungsten tip profile include apex radius, taper angle, and aspect ratio. These parameters are governed by many factors including applied voltage, concentration of the electrolyte (potassium hydroxide) solution, and diameter of the inner gold ring. However, a systematic investigation with the aim of determining the best conditions for fabricating micro/nano-scale tips with desired profiles has not been carried out yet. This study is aimed at obtaining controllable tungsten tip -particularly with respect to the radius of curvature and aspect ratio of tips (taper angle)-by altering the experimental conditions. A series of experiments were executed and the results were aggregated and analyzed using response surface methodology in order to identify the relationships between the tungsten tip characteristics and input parameters. The method proposed herein would prove to be suitable for a variety of applications in industries that require tungsten tips with a specific profile.

  18. Design of characteristic parameters for controlling tungsten tip profile during electrochemical etching

    International Nuclear Information System (INIS)

    Le Duy Cuong; Duong, Thanh Hung; Kim, Huyn Chul

    2014-01-01

    Micro/nano-scale tungsten tips fabricated by electrochemical etching have many diverse industrial applications. The characteristic parameters of the tungsten tip profile include apex radius, taper angle, and aspect ratio. These parameters are governed by many factors including applied voltage, concentration of the electrolyte (potassium hydroxide) solution, and diameter of the inner gold ring. However, a systematic investigation with the aim of determining the best conditions for fabricating micro/nano-scale tips with desired profiles has not been carried out yet. This study is aimed at obtaining controllable tungsten tip -particularly with respect to the radius of curvature and aspect ratio of tips (taper angle)-by altering the experimental conditions. A series of experiments were executed and the results were aggregated and analyzed using response surface methodology in order to identify the relationships between the tungsten tip characteristics and input parameters. The method proposed herein would prove to be suitable for a variety of applications in industries that require tungsten tips with a specific profile

  19. Alar setback technique: a controlled method of nasal tip deprojection.

    Science.gov (United States)

    Foda, H M

    2001-11-01

    To describe an alar cartilage-modifying technique aimed at decreasing nasal tip projection in cases with overdeveloped alar cartilages and to compare it with other deprojection techniques used to correct such deformity. Selected case series. University and private practice settings in Alexandria, Egypt. Twenty patients presenting for rhinoplasty who had overprojected nasal tips primarily due to overdeveloped alar cartilages. All cases were primary cases except for one patient, who had undergone 2 previous rhinoplasties. An external rhinoplasty approach was used to set back the alar cartilages by shortening their medial and lateral crura. The choice of performing a high or low setback depended on the preexisting lobule-to-columella ratio. Following the setback, the alar cartilages were reconstructed in a fashion that increased the strength and stability of the tip complex. Subjective evaluation included clinical examination, analysis of preoperative and postoperative photographs, and patient satisfaction. Objective evaluation of nasal tip projection, using the Goode ratio and the nasofacial angle, was performed preoperatively and repeated at least 6 months postoperatively. A low setback was performed in 16 cases (80%) and a high setback in 4 (20%). The mean follow-up period was 18 months (range, 6-36 months). The technique effectively deprojected the nasal tip as evidenced by the considerable postoperative decrease in values of the Goode ratio and the nasofacial angle. No complications were encountered and no revision surgical procedures were required. The alar setback technique has many advantages; it results in precise predictable amounts of deprojection, controls the degree of tip rotation, preserves the natural contour of the nasal tip, respects the tip support mechanisms, increases the strength and stability of nasal tip complex, preserves or restores the normal lobule-to-columella proportion, and does not lead to alar flaring. However, the technique requires

  20. Tip-over Prevention: Adaptive Control Development

    Science.gov (United States)

    2015-05-30

    Tip-over Prevention: Adaptive Control Development Leah Kelley Massachusetts Institute of Technology Cambridge, MA 02139 Email: lckelley@mit.edu Kurt...Papadopoulos and D. Rey, Proc. IEEE ICRA, vol.4, 1996, pp. 3111. [7] S. Ali, A. Moosavian, and K. Alipour, Robotics, Automation and Mechatronics , 2006 IEEE Conf...on, 2006, pp. 1–6. [8] K. Talke, L. Kelley, P. Longhini, and G. Catron, Proc. SPIE 9084, Unmanned Systems Technology XVI, June 2014, pp. 90 840L–11

  1. Control of droplet morphology for inkjet-printed TIPS-pentacene transistors

    Science.gov (United States)

    Lee, Myung Won; Ryu, Gi Seong; Lee, Young Uk; Pearson, Christopher; Petty, Michael C.; Song, Chung Kun

    2012-01-01

    We report on methods to control the morphology of droplets of 6,13-bis(triisopropyl-silylethynyl) pentacene (TIPS-PEN), which are then used in the fabrication of organic thin film transistors (OTFTs). The grain size and distribution of the TIPS-PEN were found to depend on the temperature of the droplets during drying. The performance of the OTFTs could be improved by heating the substrate and also by changing the relative positions of the inkjet-printed droplets. In our experiments, the optimum substrate temperature was 46 °C in air. Transistors with the TIPS-PEN grain boundaries parallel to the current flow between the source and drain electrodes exhibited charge carrier mobilities of 0.44 ± 0.08 cm2/V s.

  2. Study on unsteady tip leakage vortex cavitation in an axial-flow pump using an improved filter-based model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Desheng; Shi, Lei; Zhao, Ruijie; Shi, Weidong; Pan, Qiang [Jiangsu University, Zhenjiang (China); Esch, B. P. [Eindhoven University of Technology, Eindhoven (Netherlands)

    2017-02-15

    The aim of the present investigation is to simulate and analyze the tip leakage flow structure and instantaneous evolution of tip vortex cavitation in a scaled axial-flow pump model. The improved filter-based turbulence model based on the density correction and a homogeneous cavitation model were used for implementing this work. The results show that when entering into the tip clearance, the backward flow separates from the blade tip near the pressure side, resulting in the generation of a corner vortex with high magnitude of turbulence kinetic energy. Then, at the exit of the tip clearance, the leakage jets would re-attach on the blade tip wall. Moreover, the maximum swirling strength method was employed in identifying the TLV core and a counter-rotating induced vortex near the end-wall successfully. The three dimensional cavitation patterns and in-plain cavitation structures obtained by the improved numerical method agree well with the experimental results. At the sheet cavitation trailing edge in the tip region, the perpendicular cavitation cloud induced by TLV sheds and migrates toward the pressure side of the neighboring blade. During its migration, it breaks down abruptly and generates a large number of smallscale cavities, leading to severe degradation of the pump performance, which is similar with the phenomenon observed by Tan et al.

  3. Performance prediction and flow field calculation for airfoil fan with impeller inlet clearance

    International Nuclear Information System (INIS)

    Kang, Shin Hyoung; Cao, Renjing; Zhang, Yangjun

    2000-01-01

    The performance prediction of an airfoil fan using a commercial code, STAR/CD, is verified by comparing the calculated results with measured performance data and velocity fields of an airfoil fan. The effects of inlet tip clearance on performance are investigated. The calculations overestimate the pressure rise performance by about 10-25 percent. However, the performance reduction due to tip clearance is well predicted by numerical simulations. Main source of performance decrease is not only the slip factor but also impeller efficiency. The reduction in performance is 12-16 percent for 1 percent gap of the diameter. The calculated reductions in impeller efficiency and slip factor are also linearly proportional to the gap size. The span-wise distributions of phase averaged velocity and pressure at the impeller exit are strongly influenced by the radial gap size. The radial component of velocity and the flow angle increase over the passage as the gap increases. The slip factor decreases and the loss increases with the gap size. The high velocity of leakage jet affects the impeller inlet and passage flows. With a larger clearance, the main stream moves to the impeller hub side and high loss region extends from the shroud to the hub

  4. Characterization of metal-coated fiber tip for NSOM lithography by tip-to-tip scan

    International Nuclear Information System (INIS)

    Kubicova, I.; Pudis, D.; Suslik, L.; Skriniarova, J.

    2011-01-01

    For the optical field characterization, a tip-to-tip scan of two metal-coated fiber tips with circular aperture at the apex was performed. The optical field irradiated from the fiber probe in illumination mode was analyzed by NSOM represented by fiber probe in collection mode. The near-field intensity profile of the source fiber tip in the plane perpendicular to the axis of the tip was taken. Experimental stage requires high resolution 3D motion system controlled by computer (Fig. 1). The source and the detector fiber tip were placed on the moving and static part of the 3D nanoposition system, respectively. As a light source, a modulated 473 nm DPSS laser was used. After the source fiber tip characterization, the NSOM lithography was performed. In the experimental setup from Fig. 1, the detector fiber tip was replaced by a sample fixed in a vacuum holder. As a sample, a 600 nm positive photoresist AZ 5214E was spin-coated on a GaAs substrate. Exposure was carried out by irradiation of the sample at desired positions through the fiber tip aperture. The sample was developed in AZ 400K developer for 30 s and rinsed in DI water. A promising tip-to-tip scanning technique for characterization of metal-coated fiber tips with aperture at the apex was presented. Nearly-circular aperture shapes were documented from NSOM measurements with diameter estimated to be less than 460 nm. By knowing the source-detector distance and the FWHM of the near-field intensity profile, the tip-to-tip scan proves an easy and fast method to analyze the fiber tip aperture properties. The fiber tip resolution was confirmed by preparation of 2D planar structures in thin photoresist layer, where the NSOM lithography uses the metal-coated fiber tip characterized in previous section. (authors)

  5. Tip Vortex and Wake Characteristics of a Counterrotating Open Rotor

    Science.gov (United States)

    VanZante, Dale E.; Wernet, Mark P.

    2012-01-01

    One of the primary noise sources for Open Rotor systems is the interaction of the forward rotor tip vortex and blade wake with the aft rotor. NASA has collaborated with General Electric on the testing of a new generation of low noise, counterrotating Open Rotor systems. Three-dimensional particle image velocimetry measurements were acquired in the intra-rotor gap of the Historical Baseline blade set. The velocity measurements are of sufficient resolution to characterize the tip vortex size and trajectory as well as the rotor wake decay and turbulence character. The tip clearance vortex trajectory is compared to results from previously developed models. Forward rotor wake velocity profiles are shown. Results are presented in a form as to assist numerical modeling of Open Rotor system aerodynamics and acoustics.

  6. Development of the clearance level verification evaluation system. 2. Construction of the clearance data management system

    International Nuclear Information System (INIS)

    Kubota, Shintaro; Usui, Hideo; Kawagoshi, Hiroshi

    2014-06-01

    Clearance is defined as the removal of radioactive materials or radioactive objects within authorized practices from any further regulatory control by the regulatory body. In Japan, clearance level and a procedure for its verification has been introduced under the Laws and Regulations, and solid clearance wastes inspected by the national authority can be handled and recycled as normal wastes. The most prevalent type of wastes have generated from the dismantling of nuclear facilities, so the Japan Atomic Energy Agency (JAEA) has been developing the Clearance Level Verification Evaluation System (CLEVES) as a convenient tool. The Clearance Data Management System (CDMS), which is a part of CLEVES, has been developed to support measurement, evaluation, making and recording documents with clearance level verification. In addition, validation of the evaluation result of the CDMS was carried out by inputting the data of actual clearance activities in the JAEA. Clearance level verification is easily applied by using the CDMS for the clearance activities. (author)

  7. Establishing exemption and clearance criteria by the regulatory authority

    International Nuclear Information System (INIS)

    Salih, A.E.A.

    2012-04-01

    This Project work discusses the relationship between the concepts of exemption and clearance, and their practical use in the overall scheme of regulatory control of practices. It also discusses how exemptions and clearance is established and the scope of its applications for regulatory control. The concept of general clearance levels for any type of material and any possible pathway of disposal is also introduced in this work. Guidance of the Group of Experts establishing scenarios for general clearance, parameter values, and a nuclide-specific list of calculated clearance levels is also presented. Regulatory authorities are required to develop guidance on exemption and clearance levels to assist licensees and registrants to know which practices and sources within practices are exempted from regulatory control and those to be cleared from further controls. Exemption and clearance levels are tools for assisting the Regulatory Authority to optimize the use of resources. (author)

  8. Standpipe-bubbler pump level control study: 1E-3862, controlled clearance pump/system Model W. P. 7373. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Computer simulation results of the standpipe-bubbler pump level control system/controlled clearance pump configuration 1E-3862 using specific plan elevations are presented. Fluid level control system behavior is presented in graphical form for normal plant loading, unloading, and trip transients. Satisfactory fluid level control can be attained for this configuration with a standpipe-bubbler system.

  9. Stabilizing device for control rod tip

    International Nuclear Information System (INIS)

    Verdone, G.F.

    1982-01-01

    A control rod has a spring device on its lower end for eliminating oscillatory contact of the rod against its adjacent guide tube wall. The base of the device is connected to the lower tip of the rod. A plurality of elongated extensions are cantilevered downward from the base. Each extension has a shoulder for contacting the guide tube, and the plurality of shoulders as a group has a transverse dimension that is preset to be larger than the inner diameter of the guide tube such that an interference fit is obtained when the control rod is inserted in the tube. The elongated extensions form an open-ended, substantially hollow member through which most of the liquid coolant flows, and the spaces between adjacent extensions allow the flow to bypass the shoulders without experiencing a significant pressure drop

  10. Tip-tilt disturbance model identification based on non-linear least squares fitting for Linear Quadratic Gaussian control

    Science.gov (United States)

    Yang, Kangjian; Yang, Ping; Wang, Shuai; Dong, Lizhi; Xu, Bing

    2018-05-01

    We propose a method to identify tip-tilt disturbance model for Linear Quadratic Gaussian control. This identification method based on Levenberg-Marquardt method conducts with a little prior information and no auxiliary system and it is convenient to identify the tip-tilt disturbance model on-line for real-time control. This identification method makes it easy that Linear Quadratic Gaussian control runs efficiently in different adaptive optics systems for vibration mitigation. The validity of the Linear Quadratic Gaussian control associated with this tip-tilt disturbance model identification method is verified by experimental data, which is conducted in replay mode by simulation.

  11. Servo-control of water and sodium homeostasis during renal clearance measurements in conscious rats

    DEFF Research Database (Denmark)

    Thomsen, Klaus; Shirley, David G

    2007-01-01

    Servo-controlled fluid and sodium replacement during clearance studies is used in order to prevent loss of body fluid and sodium following diuretic/natriuretic procedures. However, even under control conditions, the use of this technique is sometimes associated with increases in proximal tubular...... fluid output (assessed by lithium clearance) and excretion rates. The present study examined the reason for these increases. The first series of experiments showed that one cause is volume overloading. This can occur if the servo system is activated from the start, i.e., during the establishment...... not seen when blood samples are replaced with the animal's own red blood cells resuspended in isotonic saline. When these pitfalls are avoided, servo-controlled sodium and fluid replacement is a reliable technique that makes it possible to study the effects of natriuretic and/or diuretic stimuli without...

  12. DC-pulsed voltage electrochemical method based on duty cycle self-control for producing TERS gold tips

    International Nuclear Information System (INIS)

    Vasilchenko, V E; Kharintsev, S S; Salakhov, M Kh

    2013-01-01

    This paper presents a modified dc-pulsed low voltage electrochemical method in which a duty cycle is self tuned while etching. A higher yield of gold tips suitable for performing tip-enhanced Raman scattering (TERS) measurements is demonstrated. The improvement is caused by the self-control of the etching rate along the full surface of the tip. A capability of the gold tips to enhance a Raman signal is exemplified by TERS spectroscopy of single walled carbon nanotubes bundle, sulfur and vanadium oxide

  13. Epigenetic control of learning and memory in Drosophila by Tip60 HAT action.

    Science.gov (United States)

    Xu, Songjun; Wilf, Rona; Menon, Trisha; Panikker, Priyalakshmi; Sarthi, Jessica; Elefant, Felice

    2014-12-01

    Disruption of epigenetic gene control mechanisms in the brain causes significant cognitive impairment that is a debilitating hallmark of most neurodegenerative disorders, including Alzheimer's disease (AD). Histone acetylation is one of the best characterized of these epigenetic mechanisms that is critical for regulating learning- and memory- associated gene expression profiles, yet the specific histone acetyltransferases (HATs) that mediate these effects have yet to be fully characterized. Here, we investigate an epigenetic role for the HAT Tip60 in learning and memory formation using the Drosophila CNS mushroom body (MB) as a well-characterized cognition model. We show that Tip60 is endogenously expressed in the Kenyon cells, the intrinsic neurons of the MB, and in the MB axonal lobes. Targeted loss of Tip60 HAT activity in the MB causes thinner and shorter axonal lobes while increasing Tip60 HAT levels cause no morphological defects. Functional consequences of both loss and gain of Tip60 HAT levels in the MB are evidenced by defects in immediate-recall memory. Our ChIP-Seq analysis reveals that Tip60 target genes are enriched for functions in cognitive processes, and, accordingly, key genes representing these pathways are misregulated in the Tip60 HAT mutant fly brain. Remarkably, we find that both learning and immediate-recall memory deficits that occur under AD-associated, amyloid precursor protein (APP)-induced neurodegenerative conditions can be effectively rescued by increasing Tip60 HAT levels specifically in the MB. Together, our findings uncover an epigenetic transcriptional regulatory role for Tip60 in cognitive function and highlight the potential of HAT activators as a therapeutic option for neurodegenerative disorders. Copyright © 2014 by the Genetics Society of America.

  14. Understanding and Mitigating Tip Leakage and Endwall Losses in High Pressure Ratio Cores

    Science.gov (United States)

    Christophel, Jesse

    2015-01-01

    Reducing endwall and tip secondary flow losses will be a key enabler for the next generation of commercial and military air transport and will be an improvement on the state-of-the-art in turbine loss reduction strategies. The objective of this research is three-fold: 1) To improve understanding of endwall secondary flow and tip clearance losses 2) To develop novel technologies to mitigate these losses and test them in low-speed cascade and rig environments 3) To validate predictive tools To accomplish these objectives, Pratt & Whitney (P&W) has teamed with Pennsylvania State University (PSU) to experimentally test new features designed by P&W. P&W will create new rim-cavity features to reduce secondary flow loss and improve purge flow cooling effectiveness and new blade tip features to manage leakage flows and reduce tip leakage secondary flow loss. P&W is currently developing technologies in these two areas that expect to be assimilated in the N+2/N+3 generation of commercial engines.

  15. Study on clearance system

    International Nuclear Information System (INIS)

    Onishi, Yuko; Miura, Hiroshi; Kawasaki, Satoru

    2011-01-01

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports NISA on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In reactor facilities, the bulk measurement technique or the statistical sampling measurement technique may be applied to large scale objects or concrete walls. In this study, the criteria of those techniques were examined. In uranium processing facilities, it is important to confirm surface state of the object in case of detecting alpha rays. The result of the examination about the influence of the surface rust in the uranium clearance measurement by the alpha ray measurement showed that the pollution was distributed in rust layer uniformly. This result will be reflected to the revision of the Ministerial Ordinance on Clearance in 2011FY. To develop a manual for unexpected incidents, the response procedure for an unexpected incident was prepared, including a response system. (author)

  16. Study on clearance system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports Nuclear Regulatory Agency on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In uranium processing facilities, simulation sources emitting alpha-rays is used in a validity confirmation examination of the measuring equipment. In this study, these sources were examined by measuring alpha and beta spectra to evaluate the applicability and problem of these sources. In addition, the measuring method detecting gamma-rays was examined. This method can be applied to complicated objects. As a part to develop a manual for unexpected incidents in clearance system, a quick method for measurement of Strontium 90 was examined. In addition, the measuring methods for the judgment of the influence of fallout and for NR (Non-Radioactive) confirmation were examined. (author)

  17. Control of the Water Transport Activity of Barley HvTIP3;1 Specifically Expressed in Seeds.

    Science.gov (United States)

    Utsugi, Shigeko; Shibasaka, Mineo; Maekawa, Masahiko; Katsuhara, Maki

    2015-09-01

    Tonoplast intrinsic proteins (TIPs) are involved in the transport and storage of water, and control intracellular osmotic pressure by transporting material related to the water potential of cells. In the present study, we focused on HvTIP3;1 during the periods of seed development and desiccation in barley. HvTIP3;1 was specifically expressed in seeds. An immunochemical analysis showed that HvTIP3;1 strongly accumulated in the aleurone layers and outer layers of barley seeds. The water transport activities of HvTIP3;1 and HvTIP1;2, which also accumulated in seeds, were measured in the heterologous expression system of Xenopus oocytes. When they were expressed individually, HvTIP1;2 transported water, whereas HvTIP3;1 did not. However, HvTIP3;1 exhibited water transport activity when co-expressed with HvTIP1;2 in oocytes, and this activity was higher than when HvTIP1;2 was expressed alone. This is the first report to demonstrate that the water permeability of a TIP aquaporin was activated when co-expressed with another TIP. The split-yellow fluorescent protein (YFP) system in onion cells revealed that HvTIP3;1 interacted with HvTIP1;2 to form a heterotetramer in plants. These results suggest that HvTIP3;1 functions as an active water channel to regulate water movement through tissues during the periods of seed development and desiccation. © The Author 2015. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. Morphing Wing-Tip Open Loop Controller and its Validation During Wind Tunnel Tests at the IAR-NRC

    Directory of Open Access Journals (Sweden)

    Mohamed Sadok GUEZGUEZ

    2016-09-01

    Full Text Available In this project, a wing tip of a real aircraft was designed and manufactured. This wing tip was composed of a wing and an aileron. The wing was equipped with a composite skin on its upper surface. This skin changed its shape (morphed by use of 4 electrical in-house developed actuators and 32 pressure sensors. These pressure sensors measure the pressures, and further the loads on the wing upper surface. Thus, the upper surface of the wing was morphed using these actuators with the aim to improve the aerodynamic performances of the wing-tip. Two types of ailerons were designed and manufactured: one aileron is rigid (non-morphed and one morphing aileron. This morphing aileron can change its shape also for the aerodynamic performances improvement. The morphing wing-tip internal structure is designed and manufactured, and is presented firstly in the paper. Then, the modern communication and control hardware are presented for the entire morphing wing tip equipped with actuators and sensors having the aim to morph the wing. The calibration procedure of the wing tip is further presented, followed by the open loop controller results obtained during wind tunnel tests. Various methodologies of open loop control are presented in this paper, and results obtained were obtained and validated experimentally through wind tunnel tests.

  19. Computerized automatic tip scanning operation

    International Nuclear Information System (INIS)

    Nishikawa, K.; Fukushima, T.; Nakai, H.; Yanagisawa, A.

    1984-01-01

    In BWR nuclear power stations the Traversing Incore Probe (TIP) system is one of the most important components in reactor monitoring and control. In previous TIP systems, however, operators have suffered from the complexity of operation and long operation time required. The system presented in this paper realizes the automatic operation of the TIP system by monitoring and driving it with a process computer. This system significantly reduces the burden on customer operators and improves plant efficiency by simplifying the operating procedure, augmenting the accuracy of the measured data, and shortening operating time. The process computer is one of the PODIA (Plant Operation by Displayed Information Automation) systems. This computer transfers control signals to the TIP control panel, which in turn drives equipment by microprocessor control. The process computer contains such components as the CRT/KB unit, the printer plotter, the hard copier, and the message typers required for efficient man-machine communications. Its operation and interface properties are described

  20. A study on tip leakage vortex dynamics and cavitation in axial-flow pump

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Lei; Zhang, Desheng; Jin, Yongxin; Shi, Weidong [Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013 (China); Esch, B P M van, E-mail: zds@ujs.edu.cn [Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB (Netherlands)

    2017-06-15

    The tip leakage flows and related cavitation in the tip region of an axial-flow pump were investigated in detail using the numerical and experimental methods. The numerical results of the pump model performance were in good agreement with experimental data. The flow structures in the tip clearance were clarified clearly with detailed data involving the axial velocity and turbulent kinetic energy. When depicting the feature of vortex core, the advanced vortex identification method λ {sub 2}-criterion was used. Simultaneously, the minimum tension criterion was also applied to predict the cavitation inception for different flow rates and it is consistent with the distributions of vorticity and pressure in the vortex core. The roll-up process of TLV is highly three-dimensional and the entrainment would follow different paths. Then, both the numerical and experimental approaches show the cavitation patterns for different cavitation conditions, and it also finds that slight cavitation would promote the development of tip leakage vortex (TLV) while the TLV seems to be eliminated for a low cavitation number, especially before a specific location of blade tip due to the blade loading change induced by cavitation possibly. (paper)

  1. Tip-Enhanced Raman Scattering Microscopy: A Step toward Nanoscale Control of Intrinsic Molecular Properties

    Science.gov (United States)

    Yano, Taka-aki; Hara, Masahiko

    2018-06-01

    Tip-enhanced Raman scattering microscopy, a family of scanning probe microscopy techniques, has been recognized as a powerful surface analytical technique with both single-molecule sensitivity and angstrom-scale spatial resolution. This review covers the current status of tip-enhanced Raman scattering microscopy in surface and material nanosciences, including a brief history, the basic principles, and applications for the nanoscale characterization of a variety of nanomaterials. The focus is on the recent trend of combining tip-enhanced Raman scattering microscopy with various external stimuli such as pressure, voltage, light, and temperature, which enables the local control of the molecular properties and functions and also enables chemical reactions to be induced on a nanometer scale.

  2. A Numerical Analysis of Heat Transfer and Effectiveness on Film Cooled Turbine Blade Tip Models

    Science.gov (United States)

    Ameri, A. A.; Rigby, D. L.

    1999-01-01

    A computational study has been performed to predict the distribution of convective heat transfer coefficient on a simulated blade tip with cooling holes. The purpose of the examination was to assess the ability of a three-dimensional Reynolds-averaged Navier-Stokes solver to predict the rate of tip heat transfer and the distribution of cooling effectiveness. To this end, the simulation of tip clearance flow with blowing of Kim and Metzger was used. The agreement of the computed effectiveness with the data was quite good. The agreement with the heat transfer coefficient was not as good but improved away from the cooling holes. Numerical flow visualization showed that the uniformity of wetting of the surface by the film cooling jet is helped by the reverse flow due to edge separation of the main flow.

  3. Control of lethal browning by using ascorbic acid on shoot tip ...

    African Journals Online (AJOL)

    The use of ascorbic acid during explants preparation and the effect of different concentrations of ascorbic acid in controlling lethal browning and survival of the explants in local banana cv. Mzuzu banana were investigated. The explants were taken from young suckers. The shoot tips were cultured on Murashige and Skoog's ...

  4. Lung mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, J.; Lange, P.; Nyboe, J.; Groth, S.

    1994-01-01

    The aim of this study was to establish reference values for mucociliary clearance and mucociliary clearance reserve capacity as determined by β 2 -adrenergic agonist-induced increase in mucociliary clearance. We studied 62 healthy females (n=33) and males (n=29). Their ages ranged evenly between 18 and 84 years. Fifty-three of the subjects were life-long non-smokers, while nine were ex-smokers. Multiple linear regression analyses showed that mucociliary clearance was significantly faster when the radioaerosol was deposited in the central airways than when it was deposited in the peripheral airways, and faster in life-long non-smokers than in ex-smokers. There was no influence of age, and no convincing association with sex. The variation was less within than between subjects. Mean mucociliary clearance reserve capacity was 21.3% (SD: 10.0%, P 2 agonist-induced increase in lung mucociliary clearance was significantly larger (P<0.05) than the stimulation which has previously been reported in patients with asthma, bronchiectasis or cystic fibrosis. The signal-to-noise ratio of the mucociliary clearance reserve capacity in relation to measurement of baseline mucociliary clearance indicates that measurement of mucociliary clearance reserve capacity may be a more efficient means of distinguishing between ''normal'' and ''abnormal'' mucociliary clearance than single measurement of baseline mucociliary clearance. (orig.)

  5. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  6. Servo-control of water and sodium homeostasis during renal clearance measurements in conscious rats.

    Science.gov (United States)

    Thomsen, Klaus; Shirley, David G

    2007-01-01

    Servo-controlled fluid and sodium replacement during clearance studies is used in order to prevent loss of body fluid and sodium following diuretic/natriuretic procedures. However, even under control conditions, the use of this technique is sometimes associated with increases in proximal tubular fluid output (assessed by lithium clearance) and excretion rates. The present study examined the reason for these increases. The first series of experiments showed that one cause is volume overloading. This can occur if the servo system is activated from the start, i.e., during the establishment of a suitably high urine flow rate by constant infusion of hypotonic glucose solution. The second series of experiments showed that replacement of blood samples with donor blood can also lead to increases in fractional lithium excretion and accompanying increases in water and sodium excretion, a problem not seen when blood samples are replaced with the animal's own red blood cells resuspended in isotonic saline. When these pitfalls are avoided, servo-controlled sodium and fluid replacement is a reliable technique that makes it possible to study the effects of natriuretic and/or diuretic stimuli without interference from unwanted changes in extracellular volume. 2007 S. Karger AG, Basel

  7. Robust Stability Clearance of Flight Control Law Based on Global Sensitivity Analysis

    OpenAIRE

    Ou, Liuli; Liu, Lei; Dong, Shuai; Wang, Yongji

    2014-01-01

    To validate the robust stability of the flight control system of hypersonic flight vehicle, which suffers from a large number of parametrical uncertainties, a new clearance framework based on structural singular value ( $\\mu $ ) theory and global uncertainty sensitivity analysis (SA) is proposed. In this framework, SA serves as the preprocess of uncertain model to be analysed to help engineers to determine which uncertainties affect the stability of the closed loop system more slightly. By ig...

  8. Tip-Enhanced Nano-Spectroscopy, Imaging, and Control: From Single Molecules to van der Waals Materials

    Science.gov (United States)

    Park, Kyoung-Duck

    Photon-induced phenomena in molecules and other materials play a significant role in device applications as well as understanding their physical properties. While a range of device applications using organic and inorganic molecules and soft and hard materials have led striking developments in modern technologies, using bulk systems has reached the limit in their functions, performance, and regarding application range. Recently, low-dimensional systems have emerged as appealing resources for the advanced technologies based on their significantly improved functions and properties. Hence, understanding light-matter interactions at their natural length scale is of fundamental significance, in addition to the next generation device applications. This thesis demonstrates a range of new functions and behaviors of low-dimensional materials revealed and controlled by the advanced tip-enhanced near-field spectroscopy and imaging techniques exceeding the current instrumental limits. To understand the behaviors of zero-dimensional (0D) molecular systems in interacting environments, we explore new regimes in tip-enhanced Raman spectroscopy (TERS) and scanning near-field optical microscopy (SNOM), revealing the fundamental nature of single-molecule dynamics and nanoscale spatial heterogeneity of biomolecules on the cell membranes. To gain insight into intramolecular properties and dynamic processes of single molecules, we use TERS at cryogenic temperatures. From temperature-dependent line narrowing and splitting, we investigate and quantify ultrafast vibrational dephasing, intramolecular coupling, and conformational heterogeneity. Through correlation analysis of fluctuations of individual modes, we observe rotational motion and spectral fluctuations of single-molecule. We extend single-molecule spectroscopy study into in situ nano-biomolecular imaging of cancer cells by developing in-liquid SNOM. We use a new mechanical resonance control, achieving a high-Q force sensing of the

  9. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  10. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  11. Dielectrophoretic positioning of single nanoparticles on atomic force microscope tips for tip-enhanced Raman spectroscopy.

    Science.gov (United States)

    Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang

    2015-05-01

    Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Polarization Control with Plasmonic Antenna Tips: A Universal Approach to Optical Nanocrystallography and Vector-Field Imaging

    Science.gov (United States)

    Park, Kyoung-Duck; Raschke, Markus B.

    2018-05-01

    Controlling the propagation and polarization vectors in linear and nonlinear optical spectroscopy enables to probe the anisotropy of optical responses providing structural symmetry selective contrast in optical imaging. Here we present a novel tilted antenna-tip approach to control the optical vector-field by breaking the axial symmetry of the nano-probe in tip-enhanced near-field microscopy. This gives rise to a localized plasmonic antenna effect with significantly enhanced optical field vectors with control of both \\textit{in-plane} and \\textit{out-of-plane} components. We use the resulting vector-field specificity in the symmetry selective nonlinear optical response of second-harmonic generation (SHG) for a generalized approach to optical nano-crystallography and -imaging. In tip-enhanced SHG imaging of monolayer MoS$_2$ films and single-crystalline ferroelectric YMnO$_3$, we reveal nano-crystallographic details of domain boundaries and domain topology with enhanced sensitivity and nanoscale spatial resolution. The approach is applicable to any anisotropic linear and nonlinear optical response, and provides for optical nano-crystallographic imaging of molecular or quantum materials.

  13. Neural adaptive control for vibration suppression in composite fin-tip of aircraft.

    Science.gov (United States)

    Suresh, S; Kannan, N; Sundararajan, N; Saratchandran, P

    2008-06-01

    In this paper, we present a neural adaptive control scheme for active vibration suppression of a composite aircraft fin tip. The mathematical model of a composite aircraft fin tip is derived using the finite element approach. The finite element model is updated experimentally to reflect the natural frequencies and mode shapes very accurately. Piezo-electric actuators and sensors are placed at optimal locations such that the vibration suppression is a maximum. Model-reference direct adaptive neural network control scheme is proposed to force the vibration level within the minimum acceptable limit. In this scheme, Gaussian neural network with linear filters is used to approximate the inverse dynamics of the system and the parameters of the neural controller are estimated using Lyapunov based update law. In order to reduce the computational burden, which is critical for real-time applications, the number of hidden neurons is also estimated in the proposed scheme. The global asymptotic stability of the overall system is ensured using the principles of Lyapunov approach. Simulation studies are carried-out using sinusoidal force functions of varying frequency. Experimental results show that the proposed neural adaptive control scheme is capable of providing significant vibration suppression in the multiple bending modes of interest. The performance of the proposed scheme is better than the H(infinity) control scheme.

  14. [51Cr]EDTA plasma clearance and endogenous creatinine clearance in advanced renal insufficiency

    International Nuclear Information System (INIS)

    Svendsen, U.G.; Munck, O.; Czartoryski, A.; Stafanger, G.

    1978-01-01

    Comparison of [ 51 Cr]EDTA plasma clearance corrected for extrarenal elimination with 24 h endogenous creatinine clearance in patients with advanced renal failure showed that the corrected [ 51 Cr]EDTA clearance was lower than creatinine clearance, and thus might be a better approximation to the glomerular filtration rate in uraemic patients. The corrections cannot be used on [ 51 Cr]EDTA clearance values below the mean extrarenal clearance, averaging 3.7 ml/min. (Auth.)

  15. Active control of the tip vortex: an experimental investigation on the performance characteristics of a model turbine

    International Nuclear Information System (INIS)

    Anik, E; Abdulrahim, A; Ostovan, Y; Mercan, B; Uzol, O

    2014-01-01

    This study is part of an on-going experimental research campaign that focuses on the active control of the tip leakage/vortex characteristics of a model horizontal axis wind turbine rotor using tip injection. This paper presents both baseline (no-injection) data as well as data with tip injection, concentrating on the effects of tip injection on power and thrust variations with the Tip Speed Ratio (TSR). The experiments are conducted by placing a specially designed 3-bladed model wind turbine rotor at the exit of a 1.7 m diameter open-jet wind tunnel. The rotor blades are non-linearly twisted and tapered with NREL S826 airfoil profile all along the span. The nacelle, hub and the blades are specifically designed to allow pressurized air to pass through and get injected from the blade tips while the rotor is rotating. Baseline results show that the general trends are as expected for a small wind turbine and the maximum power coefficient is reached at around TSR=4.5. Results with injection show that the tip injection has significant effect on the power and thrust coefficients in comparison to the baseline data, especially at TSR values higher than the max C P TSR value. Both coefficients seem to be significantly increased due to tip injection and the max C P TSR value also gets shifted to a slightly higher TSR value. Tip injection seems to have no significant effect for TSR values less than 3.5

  16. Noninvasive determination of individual renal clearance

    International Nuclear Information System (INIS)

    Chanard, J.; Brunois, J.P.; Ruiz, J.C.; Assailly, J.

    1980-01-01

    A noninvasive method for measurement of individual renal clearance is presented, based on analysis of the early rise of the kidneys' time-activity curves after injection of an appropriate tracer ( 131 I-ortho-iodohippurate for tubular function or 111 In DTPA for glomerular clearance). The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore, the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. After blood background subtraction, the linear correlation between the early part of the renogram and the corresponding blood integral activity curve allows calculation of an angular coefficient. The ratio of these coefficients calculated for each kidney is proportional to the ratio of the individual clearances. The latter are calculated from the total clearance simultaneously measured using a simplified method without urine collection. In control subjects with normal renal function individual renal clearances were not significantly different. In uninephrectomized patients a precision of 5% in calculating individual clearance was estimated from data recorded at the level of the remaining kidney. In patients with functional asymmetry, results were compared with 197 HgCl 2 quantitative renal fixation. A linear correlation was found (r = 0.95). The method we propose seems valuable for clinical investigation and allows sequential measurements. (orig.)

  17. New CSA guideline for the exemption or clearance from regulatory control of materials that contain, or potentially contain, nuclear substances

    International Nuclear Information System (INIS)

    Rhodes, M.; Kwong, A.

    2011-01-01

    The Canadian Standards Association (CSA) guideline N292.5, Guideline for the exemption or clearance from regulatory control of materials that contain, or potentially contain, nuclear substances, was recently developed to address a need for guidance on approaches for clearance of materials from facilities licensed by the Canadian Nuclear Safety Commission (CNSC) consistent with Canadian and international recommendations. This guideline is also applicable to determining if an activity associated with materials that contain nuclear substances is exempt from requiring a CNSC licence. The guideline summarizes the regulatory requirements associated with the exemption and clearance of materials and provides a graded approach to designing a survey based on the risk of residual contamination being present. (author)

  18. Robust Stability Clearance of Flight Control Law Based on Global Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    Liuli Ou

    2014-01-01

    Full Text Available To validate the robust stability of the flight control system of hypersonic flight vehicle, which suffers from a large number of parametrical uncertainties, a new clearance framework based on structural singular value (μ theory and global uncertainty sensitivity analysis (SA is proposed. In this framework, SA serves as the preprocess of uncertain model to be analysed to help engineers to determine which uncertainties affect the stability of the closed loop system more slightly. By ignoring these unimportant uncertainties, the calculation of μ can be simplified. Instead of analysing the effect of uncertainties on μ which involves solving optimal problems repeatedly, a simpler stability analysis function which represents the effect of uncertainties on closed loop poles is proposed. Based on this stability analysis function, Sobol’s method, the most widely used global SA method, is extended and applied to the new clearance framework due to its suitability for system with strong nonlinearity and input factors varying in large interval, as well as input factors subjecting to random distributions. In this method, the sensitive indices can be estimated via Monte Carlo simulation conveniently. An example is given to illustrate the efficiency of the proposed method.

  19. A Computational Study of the Oligosaccharide Binding Sites in the Lectin-Like Domain of Tumor Necrosis Factor and the TNF-derived TIP Peptide

    Czech Academy of Sciences Publication Activity Database

    Dulebo, A.; Ettrich, Rüdiger; Lucas, R.; Kaftan, D.

    2012-01-01

    Roč. 18, č. 27 (2012), s. 4236-4243 ISSN 1381-6128 Institutional support: RVO:67179843 Keywords : lectin-like domain * tumor necrosis factor * TIP peptide * oligosaccharides * molecular docking * molecular dynamics simulation * alveolar liquid clearance Subject RIV: CE - Biochemistry Impact factor: 3.311, year: 2012

  20. Mucociliary clearance

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Mortensen, Jann

    2014-01-01

    Mucociliary clearance has long been known to be a significant innate defence mechanism against inhaled microbes and irritants. Important knowledge has been gathered regarding the anatomy and physiology of this system, and in recent years, extensive studies of the pathophysiology related to lung...... pharmacological interventions on clearance rate, to study the importance of defective mucus clearance in different lung diseases or as a diagnostic tool in the work-up of patients with recurrent airway diseases. The aim of this review is to provide an overview of the anatomy, physiology, pathophysiology...

  1. A simple method for the verification of clearance levels for non-radioactive solid waste

    International Nuclear Information System (INIS)

    Holland, B.

    1997-01-01

    ANSTO's radiopharmaceutical production laboratories generate 25 m 3 of solid waste per month. Most of this waste is not radioactive. Up until recently the non-radioactive waste was cleared from the controlled area and stored for 10 halflives prior to disposal as normal solid refuse. To eliminate the storage and ''double handling'' of the large quantities of non-radioactive waste a simple clearance method was devised to allow direct disposal. This paper describes how clearance levels were determined. Here the term ''clearance level'' is used as a general term for the release of material regardless of whether it was previously subject to regulatory control. This contrasts with the IAEA definition of a clearance level and highlights a potential problem with the implementation of exemption levels to keep material out of regulatory control and the use of clearance levels to allow removal of materials from regulatory control. Several common hand held contamination monitors were tested to determine their limits of detection and ability to meet these clearance levels. The clearance method includes waste segregation and size limitation features to ensure the waste is monitored in a consistent manner, compatible with the limits of detection. The clearance levels achieved were subsequently found to be compatible with some of the unconditional clearance levels in IAEA-TECDOC-855 and the measurement method also meets the required features of that document. The ANSTO non-radioactive waste clearance system has been in operation for more than 12 months and has proved simple and effective to operate. Approximately 12m 3 of the solid waste is now been treated directly as normal solid refuse. This paper describes the ANSTO clearance system, the contamination monitor tests and details practical problems associated with the direct monitoring of solid waste, including averaging of the activity in the package. The paper also briefly highlights the potential problem with the use of

  2. Delayed clearance of triglyceride‐rich lipoproteins in young, healthy obese subjects†

    Science.gov (United States)

    Goll, R.; Lekahl, S.; Moen, O. S.; Florholmen, J.

    2015-01-01

    Summary Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age‐ and sex‐matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA‐IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA‐IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. PMID:26469529

  3. Delayed clearance of triglyceride-rich lipoproteins in young, healthy obese subjects.

    Science.gov (United States)

    Larsen, M A; Goll, R; Lekahl, S; Moen, O S; Florholmen, J

    2015-12-01

    Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age- and sex-matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA-IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA-IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. © 2015 World Obesity.

  4. Clearance of 99mTc-DTPA and experimentally increased alveolar surfactant content

    International Nuclear Information System (INIS)

    Bos, J.A.H.; Wollmer, P.; Bakker, W.; Hannappel, E.; Lachmann, B.

    1992-01-01

    The authors measured clearance of 99m Tc-labeled diethylenetriamine pentaacetic acid ( 99m Tc-DTPA) in rabbits with experimentally increased alveolar surfactant content. In one group of animals, surfactant production was increased by treatment with ambroxol, and another group of animals was treated with tracheal instillation of natural surfactant. A group of untreated control animals and animals treated with instillation of saline were also studied. Clearance was measured during standard conditions of mechanical ventilation and during ventilation with large tidal volumes. In ambroxol- and surfactant-treated groups, clearance rate was reduced compared with untreated control animals. In contrast, clearance rate increased after saline instillation. The differences were observed at both modes of ventilation. The findings indicate that the pulmonary surfactant system is a rate-limiting factor for the clearance of 99m Tc-DTPA and that the volume dependence of clearance is not explained by stretching of the alveolar wall only. 28 refs., 2 figs., 1 tab

  5. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry

    Science.gov (United States)

    Black, A.; Evans, J. C.; Hadfield, Esme H.; Macbeth, R. G.; Morgan, A.; Walsh, M.

    1974-01-01

    Black, A., Evans, J. C., Hadfield, Esme H., Macbeth, R. G., Morgan, A., and Walsh, M. (1974).British Journal of Industrial Medicine,31, 10-17. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry. Measurements of mucociliary clearance from the anterior end of the middle turbinate were made using technetium-99m-labelled particles in nine woodworkers from the furniture industry and in 12 controls, none of whom had been occupationally exposed to wood dust. Clearance rates in the controls ranged from 1·9 to 18·5 mm min-1 with a mean of 6·8. These values are in good agreement with measurements reported elsewhere for normal subjects. Only one of the woodworkers had a clearance rate which fell within the normal range and he had been occupationally exposed for the shortest period (6 years). In four woodworkers clearance was very slow (furniture industry for more than 10 years. PMID:4821406

  6. Diabetes Prevention: 5 Tips for Taking Control

    Science.gov (United States)

    ... Consider the latest diabetes prevention tips from the American Diabetes Association. There are many benefits to regular physical activity. ... if diabetes testing is appropriate for you. The American Diabetes Association recommends blood glucose screening if: You're age ...

  7. Tip studies using CFD and comparison with tip loss models

    DEFF Research Database (Denmark)

    Hansen, Martin Otto Laver; Johansen, J.

    2004-01-01

    The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD......The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD...

  8. Approaches towards establishing of clearance levels in Japan

    International Nuclear Information System (INIS)

    Sumitani, N.; Watanabe, I.; Okoshi, M.

    1998-01-01

    It is important to establish necessary regulatory systems for decommissioning waste management, especially to establish clearance levels from regulatory control. To establish the regulatory systems, the Nuclear Safety Commission (NSC) has been discussing the unconditional clearance levels for materials from nuclear reactors since May 1997. The NSC tries to derive unconditional clearance levels for the materials such as concrete and ferrous metal, arising from nuclear reactor decommissioning. In the derivation, both disposal and recycle/reuse of the materials are considered. Typical scenarios and parameter values for dose estimation are selected considering the Japanese natural and social conditions. Preliminary clearance levels were derived from 10 μSv/yr of individual dose criterion and deterministic analysis. For most radionuclides, the preliminary results are the same order of magnitude recommended in IAEA-TECDOC-855. Some radionuclides such as β emitters, however, are different order of magnitude from those recommended in IAEA-TECDOC-855. It is necessary that international organizations lead the discussions on the clearance levels to conclude final consensus. (author)

  9. A high-fidelity airbus benchmark for system fault detection and isolation and flight control law clearance

    Science.gov (United States)

    Goupil, Ph.; Puyou, G.

    2013-12-01

    This paper presents a high-fidelity generic twin engine civil aircraft model developed by Airbus for advanced flight control system research. The main features of this benchmark are described to make the reader aware of the model complexity and representativeness. It is a complete representation including the nonlinear rigid-body aircraft model with a full set of control surfaces, actuator models, sensor models, flight control laws (FCL), and pilot inputs. Two applications of this benchmark in the framework of European projects are presented: FCL clearance using optimization and advanced fault detection and diagnosis (FDD).

  10. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    DEFF Research Database (Denmark)

    Vissing, J; Ohkuwa, T; Ploug, Thorkil

    1988-01-01

    with nonimmobilized control rats (red gastrocnemius 0.46 +/- 0.02 vs. 0.99 +/- 0.08 and soleus 1.10 +/- 0.30 vs. 3.97 +/- 0.54 ml.min-1.100 g-1, P less than 0.005). During running (18 m/min), glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always......In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise......-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[3H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared...

  11. Control of internal packing seal clearances considering for shaft behavior during steam turbine operation

    Energy Technology Data Exchange (ETDEWEB)

    Pack, Min Sik; Lee, Si Yeon; Choi, Sung Choul; Lee, Jae Geun [Korea Plant Service and Engineering Co., Ltd., Seongnam (Korea, Republic of); Yang, Bo Suk [Pukyong National Univ., Busan (Korea, Republic of)

    2004-07-01

    This paper presents the characteristics of internal clearances for the interstage of blades and shaft gland seals on the steam turbine which are installed in tandem compound. Internal clearances was changed when the rotor turned in the cylindrical sleeve bearing due to the generation of oil film wedge. This presented concern is very useful to prevent the rubbing damage of seal edge between the fixed and moving parts in steam turbine due to the misalignment at the rotating and stationary parts. This method is applied for the unbalanced clearances distribution to the left and right sides in the turbine casing. A considerable amount of unbalanced clearances distribution trend is determined according to the rotating speed of rotor, size and type of journal bearing, oil viscosity, surface roughness of bearing and shaft, oil temperature, oil pressure and bearing load.

  12. A study for promoting measures of social acceptance on clearance system

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Torii, Hiroyuki; Fujii, Yasuhiko

    2007-01-01

    Clearance is one of the useful concepts to manage large amounts of slightly contaminated solid radioactive materials generated from the decommissioning of nuclear facilities. Cleared materials are expected to be disposed of as conventional wastes or recycled to produce consumer goods. In Japan, the legal frame-work for clearance was established in 2005 by amending the Law to regulate nuclear materials, reactors and so on. However, it is not so clear whether the general public understands clearance well. In this paper, major concerns about clearance from the general public are analyzed based on the public comments for reports on clearance prepared by the Nuclear Safety Commission and the Nuclear Institute Safety Agency. The major anxieties for clearance expressed by the general public are the safety of clearance, unknown factors of radiation effects, possibilities of excess radiation exposure due to inadequate measurements of radioactivities and fairness in decision making. In order to deal with those anxieties, some countermeasures including the confidence in nuclear operators and regulatory authorities and controllability of clearance by the general public are discussed to promote the social acceptance of clearance by the general public. (author)

  13. Lung clearance of 99m Tc- DTPA in systemic lupus erythematous

    International Nuclear Information System (INIS)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T.; Cunha, R.D.; Marroni, B.J.

    2002-01-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  14. Heat Transfer and Flow on the First Stage Blade Tip of a Power Generation Gas Turbine. Part 1; Experimental Results

    Science.gov (United States)

    Bunker, Ronald S.; Bailey, Jeremy C.; Ameri, Ali A.

    1999-01-01

    A combined computational and experimental study has been performed to investigate the detailed distribution of convective heat transfer coefficients on the first stage blade tip surface for a geometry typical of large power generation turbines(>100MW). This paper is concerned with the design and execution of the experimental portion of the study. A stationary blade cascade experiment has been run consisting of three airfoils, the center airfoil having a variable tip gap clearance. The airfoil models the aerodynamic tip section of a high pressure turbine blade with inlet Mach number of 0.30, exit Mach number of 0.75, pressure ratio of 1.45, exit Reynolds number based on axial chord of 2.57 x 10(exp 6), and total turning of about 110 degrees. A hue detection based liquid crystal method is used to obtain the detailed heat transfer coefficient distribution on the blade tip surface for flat, smooth tip surfaces with both sharp and rounded edges. The cascade inlet turbulence intensity level took on values of either 5% or 9%. The cascade also models the casing recess in the shroud surface ahead of the blade. Experimental results are shown for the pressure distribution measurements on the airfoil near the tip gap, on the blade tip surface, and on the opposite shroud surface. Tip surface heat transfer coefficient distributions are shown for sharp-edge and rounded-edge tip geometries at each of the inlet turbulence intensity levels.

  15. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    International Nuclear Information System (INIS)

    Vissing, J.; Ohkuwa, Tetsuo; Ploug, T.; Galbo, H.

    1988-01-01

    In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[ 3 H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared with nonimmobilized control rats. During running, glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always similar in the two groups and decreased during exercise. Intracellular nonphosphorylated 2DG was present in tissues with high glucose clearances. In conclusion, 42 h of immobilization markedly impairs glucose clearance of resting red muscle fibers in vivo. Apparently, physical inactivity in particular affects steps involved in insulin-mediated action that are not part of contraction-induced glucose uptake and metabolism. Presence of intracellular 2DG shows that separate determination of phosphorylated 2DG is necessary for accurate estimates of glucose metabolism and that accumulation of phosphorylated 2DG does not accurately reflect glucose transport

  16. Clearance of building structures for conventional non-nuclear reuse

    International Nuclear Information System (INIS)

    Buss, K.; Boehringer, S.

    1998-01-01

    At the example of a fuel assembly plant the strategy of control measurements on building surfaces, which shall be conventionally reused after their clearance, is regarded. Based on the given clearance levels the used measuring methods, especially with regard of possibly covered or intruded uranium contamination, are shown. The possibility of using the in-situ-γ-spectroscopy is discussed. (orig.) [de

  17. Sub-harmonic broadband humps and tip noise in low-speed ring fans.

    Science.gov (United States)

    Moreau, Stéphane; Sanjose, Marlène

    2016-01-01

    A joint experimental and numerical study has been achieved on a low-speed axial ring fan in clean inflow. Experimental evidence shows large periodic broadband humps at lower frequencies than the blade passing frequencies and harmonics even at design conditions. These sub-harmonic humps are also found to be sensitive to the fan process and consequently to its tip geometry. Softer fans yield more intense humps more shifted to lower frequencies with respect to the fan harmonics. Unsteady turbulent flow simulations of this ring fan mounted on a test plenum have been achieved by four different methods that have been validated by comparing with overall performances and detailed hot-wire velocity measurements in the wake. Noise predictions are either obtained directly or are obtained through Ffowcs Williams and Hawkings' analogy, and compared with narrowband and third-octave power spectra. All unsteady simulations correctly capture the low flow rates, the coherent vortex dynamics in the tip clearance and consequently the noise radiation dominated by the tip noise in the low- to mid-frequency range. Yet, only the scale-adaptive simulation and the lattice Boltzmann method simulations which can describe most of the turbulent structures accurately provide the proper spectral shape and levels, and consequently the overall sound power level.

  18. Effects and outcome of Tamsulosin more than just stone clearance after extracorporeal shock wave lithotripsy for renal calculi

    International Nuclear Information System (INIS)

    Qadri, S. S. U.; Khalid, S. E.; Mahmud, S. M.

    2014-01-01

    Objective: To determine the effect of Tamsulosin, as adjunctive medical therapy after Extracorporeal Shock Wave Lithotripsy for renal stones on rate of stone clearance, clearance time, pain intensity during stone clearance, steinstrasse formation and auxiliary surgical intervention required. Method: A prospective randomized controlled study was carried out in 120 patients who underwent ESWL for renal stones of 0.5-2.0 cm. They were randomized into study and control group in which Tamsulosin 0.4mg/day was given in former as an adjunctive medical therapy. All patients underwent ESWL every 2 weeks until complete stone clearance for 8 weeks. The parameters assessed were stone clearance, clearance time, pain intensity and effect on steinstrasse. Results: Of the 120 patients 60 were in each group. The stone clearance rate was greater in study than in control group, 58(96.7%) vs. 48(80%) respectively, (p<0.004). The mean stone clearance time was observed earlier in study group as compared to control group with significant statistical difference in stone size between 0.6-1.5 cm. The mean intensity of pain patients experienced according to Visual analogue scale (VAS) was significantly less in study group (p<0.002). The rate of steinstrasse formation was observed to be higher in control than in study group 15(25%) vs 6(10%) respectively(p<0.003), while its spontaneous clearance was higher in study group than in control group 83.3% vs 33.3% (p<0.03). Conclusion: Tamsulosin significantly increases stone clearance after shock wave lithotripsy for renal stones. It also appeared to facilitate earlier stone clearance, reduces severity of pain, reduces the incidence of steinstrasse formation and tends to facilitate its spontaneous clearance. (author)

  19. Enhancing Raman signals with an interferometrically controlled AFM tip

    International Nuclear Information System (INIS)

    Oron-Carl, Matti; Krupke, Ralph

    2013-01-01

    We demonstrate the upgrade of a commercial confocal Raman microscope into a tip-enhanced Raman microscope/spectroscopy system (TERS) by integrating an interferometrically controlled atomic force microscope into the base of an existing upright microscope to provide near-field detection and thus signal enhancement. The feasibility of the system is demonstrated by measuring the Raman near-field enhancement on thin PEDOT:PSS films and on carbon nanotubes within a device geometry. An enhancement factor of 2–3 and of 5–6 is observed, respectively. Moreover, on a nanotube device we show local conductivity measurement and its correlation to Raman and topography recordings. Upgrading an existing upright confocal Raman microscope in the demonstrated way is significantly cheaper than purchasing a complete commercial TERS system. (paper)

  20. Aerobic fitness in patients with fibrositis. A controlled study of respiratory gas exchange and 133-xenon clearance from exercising muscle

    International Nuclear Information System (INIS)

    Bennett, R.M.; Clark, S.R.; Goldberg, L.; Nelson, D.; Bonafede, R.P.; Porter, J.; Specht, D.

    1989-01-01

    Aerobic fitness was evaluated in 25 women with fibrositis, by having them exercise to volitional exhaustion on an electronically braked cycle ergometer. Compared with published standards, greater than 80% of the fibrositis patients were not physically fit, as assessed by maximal oxygen uptake. Compared with matched sedentary controls, fibrositis patients accurately perceived their level of exertion in relation to oxygen consumption and attained a similar level of lactic acidosis, as assessed by their respiratory quotient and ventilatory threshold. Exercising muscle blood flow was estimated by 133-xenon clearance in a subgroup of 16 fibrositis patients and compared with that in 16 matched sedentary controls; the fibrositis patients exhibited reduced 133-xenon clearance. These results indicate a need to include aerobic fitness as a matched variable in future controlled studies of fibrositis and suggest that the detraining phenomenon may be of relevance to the etiopathogenesis of the disease

  1. Production of plastic scintillation survey meter for clearance verification measurement

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu; Tomii, Hiroyuki

    2008-03-01

    In the Nuclear Science Research Institute, the decommissioning of various nuclear facilities is carried out according to the plan for meeting the midterm goal of the Japan Atomic Energy Agency (JAEA). An increase in the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas will be expected along with the dismantlement of nuclear facilities in the future. The radiation measurement for releasing controlled areas has been carried out in small-scale nuclear facilities including the JPDR (Japan Power Demonstration Reactor). However, the radiation measurement with an existing measuring device was difficult in effects of radiation from radioactive materials that remains in buried piping. On the other hand, there is no experience that the clearance verification measurement is executed in the JAEA. The generation of a large amount of clearance object will be expected along with the decommissioning of the nuclear facilities in the future. The plastic scintillation survey meter (hereafter, 'PL measuring device') was produced to apply to the clearance verification measurement and the radiation measurement for releasing controlled areas. The basic characteristic test and the actual test were confirmed using the PL measuring device. As a result of these tests, it was found that the evaluation value of radioactivity with the PL measuring device was accuracy equal with the existing measuring device. The PL measuring device has feature of the existing measuring device with a light weight and easy operability. The PL measuring device can correct the gamma ray too. The PL measuring device is effective to the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas. (author)

  2. Imaging contrast and tip-sample interaction of non-contact amplitude modulation atomic force microscopy with Q -control

    International Nuclear Information System (INIS)

    Shi, Shuai; Guo, Dan; Luo, Jianbin

    2017-01-01

    Active quality factor ( Q ) exhibits many promising properties in dynamic atomic force microscopy. Energy dissipation and image contrasts are investigated in the non-contact amplitude modulation atomic force microscopy (AM-AFM) with an active Q -control circuit in the ambient air environment. Dissipated power and virial were calculated to compare the highly nonlinear interaction of tip-sample and image contrasts with different Q gain values. Greater free amplitudes and lower effective Q values show better contrasts for the same setpoint ratio. Active quality factor also can be employed to change tip-sample interaction force in non-contact regime. It is meaningful that non-destructive and better contrast images can be realized in non-contact AM-AFM by applying an active Q -control to the dynamic system. (paper)

  3. Radiative control of dark excitons at room temperature by nano-optical antenna-tip Purcell effect

    Science.gov (United States)

    Park, Kyoung-Duck; Jiang, Tao; Clark, Genevieve; Xu, Xiaodong; Raschke, Markus B.

    2018-01-01

    Excitons, Coulomb-bound electron-hole pairs, are elementary photo-excitations in semiconductors that can couple to light through radiative relaxation. In contrast, dark excitons (XD) show anti-parallel spin configuration with generally forbidden radiative emission. Because of their long lifetimes, these dark excitons are appealing candidates for quantum computing and optoelectronics. However, optical read-out and control of XD states has remained challenging due to their decoupling from light. Here, we present a tip-enhanced nano-optical approach to induce, switch and programmably modulate the XD emission at room temperature. Using a monolayer transition metal dichalcogenide (TMD) WSe2 on a gold substrate, we demonstrate 6 × 105-fold enhancement in dark exciton photoluminescence quantum yield achieved through coupling of the antenna-tip to the dark exciton out-of-plane optical dipole moment, with a large Purcell factor of ≥2 × 103 of the tip-sample nano-cavity. Our approach provides a facile way to harness excitonic properties in low-dimensional semiconductors offering new strategies for quantum optoelectronics.

  4. Dynamic of cold-atom tips in anharmonic potentials

    Science.gov (United States)

    Menold, Tobias; Federsel, Peter; Rogulj, Carola; Hölscher, Hendrik; Fortágh, József

    2016-01-01

    Background: Understanding the dynamics of ultracold quantum gases in an anharmonic potential is essential for applications in the new field of cold-atom scanning probe microscopy. Therein, cold atomic ensembles are used as sensitive probe tips to investigate nanostructured surfaces and surface-near potentials, which typically cause anharmonic tip motion. Results: Besides a theoretical description of this anharmonic tip motion, we introduce a novel method for detecting the cold-atom tip dynamics in situ and real time. In agreement with theory, the first measurements show that particle interactions and anharmonic motion have a significant impact on the tip dynamics. Conclusion: Our findings will be crucial for the realization of high-sensitivity force spectroscopy with cold-atom tips and could possibly allow for the development of advanced spectroscopic techniques such as Q-control. PMID:28144505

  5. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    Science.gov (United States)

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  6. Lung clearance of {sup 99m} Tc- DTPA in systemic lupus erythematous

    Energy Technology Data Exchange (ETDEWEB)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Dept. de Medicina Interna; Cunha, R.D.; Marroni, B.J. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Servico de Medicina Nuclear]. E-mail: rxavier@hcpa.ufrgs.br

    2002-06-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  7. Travel Tips Help IBS Sufferers Enjoy Their Vacations

    Science.gov (United States)

    ... can feel more in control when traveling." IFFGD's travel tips include: Allow enough time in the morning to get to the airport ... Heartache 2004-0929 Norton Honored 2004-0525 IBS Travel Tips ... Real World 2001-1119 Heartburn or Heart Attack Commentary ...

  8. Film cooling effects on the tip flow characteristics of a gas turbine blade

    Directory of Open Access Journals (Sweden)

    Jin Wang

    2015-03-01

    Full Text Available An experimental investigation of the tip flow characteristics between a gas turbine blade tip and the shroud was conducted by a pressure-test system and a particle image velocimetry (PIV system. A three-times scaled profile of the GE-E3 blade with five film cooling holes was used as specimen. The effects on flow characteristics by the rim width and the groove depth of the squealer tip were revealed. The rim widths were (a 0.9%, (b 2.1%, and (c 3.0% of the axial chord, and the groove depths were (a 2.8%, (b 4.8%, and (c 10% of the blade span. Several pressure taps on the top plate above the blades were connected to pressure gauges. By a CCD camera the PIV system recorded the velocity field around the leading edge zone including the five cooling holes. The flow distributions both in the tip clearance and in the passage were revealed, and the influence of the inlet velocity was determined. In this work, the tip flow characteristics with and without film cooling were investigated. The effects of different global blowing ratios of M=0.5, 1.0, 1.3 and 2.5 were established. It was found that decreasing the rim width resulted in a lower mass flow rate of the leakage flow, and the pressure distributions from the leading edge to the trailing edge showed a linearly increasing trend. It was also found that if the inlet velocity was less than 1.5 m/s, the flow field in the passage far away from the suction side appeared as a stagnation zone.

  9. Transcaval TIPS in patients with failed revision of occluded previous TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Chang Kyu; Kim, Yong Joo; Shin, Tae Beom; Park, Hyo Yong; Kim, Tae Hun; Kang, Duk Sik [Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2001-12-01

    To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  10. Robust procedure for creating and characterizing the atomic structure of scanning tunneling microscope tips.

    Science.gov (United States)

    Tewari, Sumit; Bastiaans, Koen M; Allan, Milan P; van Ruitenbeek, Jan M

    2017-01-01

    Scanning tunneling microscopes (STM) are used extensively for studying and manipulating matter at the atomic scale. In spite of the critical role of the STM tip, procedures for controlling the atomic-scale shape of STM tips have not been rigorously justified. Here, we present a method for preparing tips in situ while ensuring the crystalline structure and a reproducibly prepared tip structure up to the second atomic layer. We demonstrate a controlled evolution of such tips starting from undefined tip shapes.

  11. Role of cellular oxalate in oxalate clearance of patients with calcium oxalate monohydrate stone formation and normal controls.

    Science.gov (United States)

    Oehlschläger, Sven; Fuessel, Susanne; Meye, Axel; Herrmann, Jana; Froehner, Michael; Albrecht, Steffen; Wirth, Manfred P

    2009-03-01

    To examine the cellular, plasma, and urinary oxalate and erythrocyte oxalate flux in patients with calcium oxalate monohydrate (COM) stone formation vs normal controls. Pathologic oxalate clearance in humans is mostly integrated in calcium oxalate stone formation. An underlying cause of deficient oxalate clearance could be defective transmembrane oxalate transport, which, in many tissues, is regulated by an anion exchanger (SLC26). We studied 2 groups: 40 normal controls and 41 patients with COM stone formation. Red blood cells were divided for cellular oxalate measurement and for resuspension in a buffered solution (pH 7.40); 0.1 mmol/L oxalate was added. The supernatant was measured for oxalate immediately and 1 hour after incubation. The plasma and urinary oxalate were analyzed in parallel. The mean cellular oxalate concentrations were significantly greater in the normal controls (5.25 +/- 0.47 micromol/L) than in those with COM stone formation (2.36 +/- 0.28 micromol/L; P stone formation (0.31 +/- 0.02 mmol/L) than in the controls (0.24 +/- 0.02 mmol/L; P r = 0.49-0.63; P r = -0.29-0.41; P r = -0.30; P r = 0.25; P stone formation. Our data implicate the presence of a cellular oxalate buffer to stabilize plasma and urinary oxalate concentrations in normal controls.

  12. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  13. Evaluation of the tip-bending response in clinically used endoscopes

    NARCIS (Netherlands)

    Rozeboom, Esther; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo Adriaan Maria Johannes

    Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current

  14. Evaluation of the tip-bending response in clinically used endoscopes

    NARCIS (Netherlands)

    Rozeboom, Esther D.; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo A. M. J.

    2016-01-01

    Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current

  15. Recent activities on clearance in IAEA and clearance automatic laser inspection system (CLALIS)

    International Nuclear Information System (INIS)

    Hattori, Takatoshi; Sasaki, Michiya

    2005-01-01

    Exemption levels for bulk amounts of materials have been described in RS-G-1.7 published as a safety guide in IAEA on August 2004. In Japan, the Nuclear Safety Commission adopted the RS-G-1.7 values as Japanese clearance levels after the careful review of dose assessment results. After completing revises of regulatory laws in relation to clearance level, solid wastes from decommissioning and operating nuclear power plants will be targets of clearance inspection. In CRIEPI, Clearance Automatic Laser Inspection System (CLALIS) has been developed, which can give high reliability and objectivity to the measurement data. The CLALIS is a new monitoring system coupling with 3D laser shape measurement, Monte-Carlo calculation and gamma measurement techniques, which can keep a high accuracy in the measurement data using an automatic correction technique for self-shielding effects of metal waste itself and is expected to apply as a practical use in actual clearance inspections. (author)

  16. Generic clearance values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2009-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document 'Safety Reports Series Nr 44' of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (author)

  17. Generic Clearance Values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2010-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on the one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document Safety Reports Series 44 of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (authors) [es

  18. Robust procedure for creating and characterizing the atomic structure of scanning tunneling microscope tips

    Directory of Open Access Journals (Sweden)

    Sumit Tewari

    2017-11-01

    Full Text Available Scanning tunneling microscopes (STM are used extensively for studying and manipulating matter at the atomic scale. In spite of the critical role of the STM tip, procedures for controlling the atomic-scale shape of STM tips have not been rigorously justified. Here, we present a method for preparing tips in situ while ensuring the crystalline structure and a reproducibly prepared tip structure up to the second atomic layer. We demonstrate a controlled evolution of such tips starting from undefined tip shapes.

  19. Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

    Science.gov (United States)

    Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson

    2018-05-10

    The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.

  20. Survival benefit of TIPS versus serial paracentesis in patients with refractory ascites: a single institution case-control propensity score analysis

    International Nuclear Information System (INIS)

    Gaba, R.C.; Parvinian, A.; Casadaban, L.C.; Couture, P.M.; Zivin, S.P.; Lakhoo, J.; Minocha, J.; Ray, C.E.; Knuttinen, M.G.; Bui, J.T.

    2015-01-01

    Aim: To compare the impact of covered stent-graft transjugular intrahepatic portosystemic shunt (TIPS) versus serial paracentesis on survival of patients with medically refractory ascites. Materials and methods: In this retrospective study, cirrhotic patients who underwent covered stent-graft TIPS for refractory ascites from 2003–2013 were compared with similar patients who underwent serial paracentesis during 2009–2013. Demographic and liver disease data, Model for End-Stage Liver Disease (MELD) scores, and survival outcomes were obtained from hospital electronic medical records and the social security death index. After propensity score weighting to match study group characteristics, survival outcomes were compared using Kaplan–Meier statistics with log-rank analysis. Results: Seventy TIPS (70% men, mean age 55.7 years, mean MELD 15.1) and 80 paracentesis (58% men, mean age 53.5 years, mean MELD 22.5) patients were compared. The TIPS haemodynamic success rate was 100% (mean portosystemic pressure gradient reduction 13 mmHg). Paracentesis patients underwent a mean of 7.9 procedures. After propensity score weighting to balance group features, TIPS patients showed a trend toward enhanced survival compared with paracentesis patients (median survival 1037 versus 262 days, p = 0.074). TIPS conferred a significant increase or trend toward improved survival compared with paracentesis at 1 (66% versus 44%, p = 0.018), 2 (56% versus 38%, p = 0.057), and 3 year (49% versus 32%, p = 0.077) time points. Thirty and 90 day mortality rates were not statistically increased by TIPS. Conclusion: Covered stent-graft TIPS improves intermediate- to long-term survival without significantly increasing short-term mortality of ascites patients, and suggests a greater potential role for TIPS in properly selected ascitic patients when medical management fails. - Highlights: • The survival benefit of TIPS for patients with refractory ascites remains unproven. • A case-control

  1. Glymphatic fluid transport controls paravascular clearance of AAV vectors from the brain

    Science.gov (United States)

    Murlidharan, Giridhar; Crowther, Andrew; Reardon, Rebecca A.; Song, Juan

    2016-01-01

    Adeno-associated viruses (AAV) are currently being evaluated in clinical trials for gene therapy of CNS disorders. However, host factors that influence the spread, clearance, and transduction efficiency of AAV vectors in the brain are not well understood. Recent studies have demonstrated that fluid flow mediated by aquaporin-4 (AQP4) channels located on astroglial end feet is essential for exchange of solutes between interstitial and cerebrospinal fluid. This phenomenon, which is essential for interstitial clearance of solutes from the CNS, has been termed glial-associated lymphatic transport or glymphatic transport. In the current study, we demonstrate that glymphatic transport profoundly affects various aspects of AAV gene transfer in the CNS. Altered localization of AQP4 in aged mouse brains correlated with significantly increased retention of AAV vectors in the parenchyma and reduced systemic leakage following ventricular administration. We observed a similar increase in AAV retention and transgene expression upon i.c.v. administration in AQP4–/– mice. Consistent with this observation, fluorophore-labeled AAV vectors showed markedly reduced flux from the ventricles of AQP4–/– mice compared with WT mice. These results were further corroborated by reduced AAV clearance from the AQP4-null brain, as demonstrated by reduced transgene expression and vector genome accumulation in systemic organs. We postulate that deregulation of glymphatic transport in aged and diseased brains could markedly affect the parenchymal spread, clearance, and gene transfer efficiency of AAV vectors. Assessment of biomarkers that report the kinetics of CSF flux in prospective gene therapy patients might inform variable treatment outcomes and guide future clinical trial design. PMID:27699236

  2. TIPS - anastomose portossistêmica intra-hepática transjugular. Revisão TIPS - transjugular intrahepatic portosystemic shunt. A review

    Directory of Open Access Journals (Sweden)

    Gerson CARREIRO

    2001-01-01

    Full Text Available Diversas alternativas terapêuticas têm sido usadas, atualmente, na tentativa de reduzir a mortalidade de pacientes com hipertensão portal que desenvolvem varizes esofagianas. Abordagem de uma dessas alternativas que ainda é de exceção e pouco utilizada em nosso meio - o "shunt" (desvio portossistêmico intra-hepático transjugular - TIPS ("transjugular intrahepatic portasystemic shunt". O TIPS possibilita redução significativa do gradiente de pressão portohepático, uma vez que funciona como um "shunt" portocava látero-lateral, promovendo, dessa forma, descompressão eficiente do sistema portal, reduzindo significativamente o risco de sangramentos. A técnica consiste na inserção percutânea, através da veia jugular interna, de malha metálica através do parênquima hepático, sob controle angiográfico, criando verdadeira comunicação portocava. Bons resultados na utilização do TIPS têm sido atestados em diversos estudos, muito embora bem poucos deles tenham sido controlados e randomizados de modo a concluir que esse procedimento é seguro, eficaz e com boa relação custo-benefício. Dessa forma, buscou-se, nesta revisão, uma análise do estado atual da utilização do TIPS, sua técnica, principais indicações e complicações. O TIPS vem sendo utilizado nos casos de hemorragia digestiva refratária ao tratamento farmacológico e/ou endoscópico, principalmente em pacientes Child-Pugh B e C ou ainda como opção de controle do quadro, servindo como "ponte" para um futuro transplante hepático. Pode-se considerar ainda o tratamento da ascite refratária, da síndrome hepatorrenal e do hidrotórax hepático como promissoras indicações definitivas para a colocação do TIPS. As complicações dessa técnica estão relacionadas, sobretudo, a sua colocação, às conseqüências hemodinâmicas imediatas, como a encefalopatia hepática, e às complicações tardias envolvendo principalmente a oclusão do "stent" (prótese auto

  3. Nuclear security. DOE actions to improve the personnel clearance program

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Bannerman, Carl J.; Daniel, Beverly A.

    1988-11-01

    The status of the Department of Energy's (DOE) implementation of recommendations in our two reports on DOE's personnel security clearance program was determined. The recommendations were aimed at improving the timeliness, accuracy, and efficiency of personnel security clearance decisions. Specifically, the objective was to determine and report on steps DOE is taking to implement these recommendations. In summary, it was found that DOE has either initiated action or is studying ways to address all the recommendations, but none of the recommendations have been completely implemented. The effectiveness of the DOE actions will depend, in part, on the adequacy of its internal control system for overseeing and evaluating program operations. DOE's personnel security clearance program is intended to provide reasonable assurance that personnel with access to classified information and materials are trustworthy. The Department requests that the Office of Personnel Management or the Federal Bureau of Investigation collect personal data on each person who requires such access to do his or her job. Based on these background investigations, DOE officials authorize individuals whose personal histories indicate that they are trustworthy to have access to classified information, secured facilities, and controlled materials as needed to perform their jobs. DOE has five types of these authorizations or personnel security clearances and must update information on personnel holding each type at 5-year intervals to confirm their continuing reliability. The five types are based on the types of security interests to which the person needs access, e.g., persons needing nuclear weapons-related data must have a Q clearance, and persons with a top secret clearance can have access to national security data classified as top secret

  4. A Study to Determine Clearance Levels of Radioactive Wastes in Kenya

    Energy Technology Data Exchange (ETDEWEB)

    Mukakaa, Zaphania O. [KAIST, Daejeon (Korea, Republic of); Kim, Sung Il [KINS, Daejeon (Korea, Republic of)

    2015-10-15

    Due to lack of a radioactive waste disposal facility in Kenya, radioactive wastes are stored in a bonded warehouse until such a time when their activity is low and they meet the criterion for clearance. The International Atomic Energy Agency (IAEA) has established activity concentrations of radionuclides to act as a universal guideline or standard for clearance in member countries. Radioactive wastes whose activity would yield a trivial risk to the people and environment, i.e. with an annual dose below 10 µSv are usually cleared from regulatory control with no further regulatory control mechanisms being taken. The Radiation Protection Board currently depends on the IAEA's generic clearance level activity concentrations for purposes of clearing the radiation wastes within its inventory. This study aims to determine activity concentrations of radionuclides in the Kenyan inventory that correspond to the clearance level dose of 10 µSv/a as set by the IAEA. The RESidual RADioactivity (RESRAD) computer code, an important tool developed in 1989 to aid in evaluation of sites with radioactive contamination, will aid in modeling these clearance level values using a pathways analysis method and available site-specific data from Kenya. Afterwards, the obtained clearance level values will be compared with the IAEA's generic clearance level values of the corresponding radionuclides. The results modeled using the RESRAD code are conservative. For most of the radionuclides in the Kenyan inventory, the values do correspond with the IAEA standard generic clearance level values, albeit with minor differences. For most of the radionuclides, the difference is within the acceptable uncertainty limit. For these low probability events the effective dose resulting from them should not exceed 1 mSv per year. Thus, consideration was given to doses to the skin and an equivalent dose to the skin of 50 mSv per year was duly used in estimating the clearance level activities. The

  5. Study on the Performance of a Centrifugal Compressor Using Fluid-Structure Interaction Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee Horim; Hwang, Yoonjei; Jeong, Jinhee [LG Electronics, Seoul (Korea, Republic of); Kim, Changhee; Yang, Jangsik; Son, Changmin [Pusan Nat’l Univ., Busan (Korea, Republic of)

    2016-06-15

    In this study, we perform a series of aero-thermo-mechanical analyses to predict the running-tip clearance and the effects of impeller deformation on the performance using a centrifugal compressor. During operation, the impeller deformation due to a combination of the centrifugal force, aerodynamic pressure and the thermal load results in a non-uniform tip clearance profile. For the prediction, we employ the one-way fluid-structure interaction (FSI) method using CFX 14.5 and ANSYS. The predicted running tip clearance shows a non-uniform profile over the entire flow passage. In particular, a significant reduction of the tip clearance height occurred at the leading and trailing edges of the impeller. Because of the reduction of the tip clearance, the tip leakage flow decreased by 19.4% In addition, the polytrophic efficiency under operating conditions increased by 0.72%. These findings confirm that the prediction of the running tip clearance and its impact on compressor performance is an important area that requires further investigation.

  6. Study on the Performance of a Centrifugal Compressor Using Fluid-Structure Interaction Method

    International Nuclear Information System (INIS)

    Lee Horim; Hwang, Yoonjei; Jeong, Jinhee; Kim, Changhee; Yang, Jangsik; Son, Changmin

    2016-01-01

    In this study, we perform a series of aero-thermo-mechanical analyses to predict the running-tip clearance and the effects of impeller deformation on the performance using a centrifugal compressor. During operation, the impeller deformation due to a combination of the centrifugal force, aerodynamic pressure and the thermal load results in a non-uniform tip clearance profile. For the prediction, we employ the one-way fluid-structure interaction (FSI) method using CFX 14.5 and ANSYS. The predicted running tip clearance shows a non-uniform profile over the entire flow passage. In particular, a significant reduction of the tip clearance height occurred at the leading and trailing edges of the impeller. Because of the reduction of the tip clearance, the tip leakage flow decreased by 19.4% In addition, the polytrophic efficiency under operating conditions increased by 0.72%. These findings confirm that the prediction of the running tip clearance and its impact on compressor performance is an important area that requires further investigation.

  7. Towards easy and reliable AFM tip shape determination using blind tip reconstruction

    International Nuclear Information System (INIS)

    Flater, Erin E.; Zacharakis-Jutz, George E.; Dumba, Braulio G.; White, Isaac A.; Clifford, Charles A.

    2014-01-01

    Quantitative determination of the geometry of an atomic force microscope (AFM) probe tip is critical for robust measurements of the nanoscale properties of surfaces, including accurate measurement of sample features and quantification of tribological characteristics. Blind tip reconstruction, which determines tip shape from an AFM image scan without knowledge of tip or sample shape, was established most notably by Villarrubia [J. Res. Natl. Inst. Stand. Tech. 102 (1997)] and has been further developed since that time. Nevertheless, the implementation of blind tip reconstruction for the general user to produce reliable and consistent estimates of tip shape has been hindered due to ambiguity about how to choose the key input parameters, such as tip matrix size and threshold value, which strongly impact the results of the tip reconstruction. These key parameters are investigated here via Villarrubia's blind tip reconstruction algorithms in which we have added the capability for users to systematically vary the key tip reconstruction parameters, evaluate the set of possible tip reconstructions, and determine the optimal tip reconstruction for a given sample. We demonstrate the capabilities of these algorithms through analysis of a set of simulated AFM images and provide practical guidelines for users of the blind tip reconstruction method. We present a reliable method to choose the threshold parameter corresponding to an optimal reconstructed tip shape for a given image. Specifically, we show that the trend in how the reconstructed tip shape varies with threshold number is so regular that the optimal, or Goldilocks, threshold value corresponds with the peak in the derivative of the RMS difference with respect to the zero threshold curve vs. threshold number. - Highlights: • Blind tip reconstruction algorithms have been implemented and augmented to determine the optimal input parameters. • We demonstrate the capabilities of the algorithms using a simulated AFM

  8. Clearance from the anterior chamber of RBCs from human diabetics

    International Nuclear Information System (INIS)

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-01-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects

  9. Comparison of different types of phacoemulsification tips. I. Quantitative analysis of elemental composition and tip surface microroughness.

    Science.gov (United States)

    Tsaousis, Konstantinos T; Werner, Liliana; Perez, Jesus Paulo; Li, He J; Reiter, Nicholas; Guan, Jia J; Mamalis, Nick

    2016-09-01

    To evaluate the elemental composition of phacoemulsification tips and their surface roughness in the microscale. John A. Moran Eye Center and Utah Nanofab, College of Engineering, University of Utah, Salt Lake City, Utah, USA. Experimental study. Seven types of phacoemulsification tips were studied. The phaco tips were examined through energy-dispersive x-ray spectroscopy (EDS) and x-ray photoelectron spectroscopy (XPS) for elemental composition. In addition, the roughness of the opening in all tips was assessed through 3-dimensional white-light interferometry. Elemental analysis showed considerable differences in the surface layers between manufacturers. Alcon tips had a thinner oxidized titanium (Ti) layer in their surface. Through XPS, vanadium was not detected in the superficial layers of any tip, but only in deeper levels. The microroughness surface analysis showed comparable results regarding their root-mean-square (RMS) metric. Maximum peak valley distance values varied and appeared to be dependent on the quality of material process rather than the material itself. Phacoemulsification tips are made of Ti alloys and showed differences between models, especially regarding their composition in the superficial layers. Their opening end roughness showed an overall appropriate RMS value of less than 1.0 μm in all cases. The existence of small defected areas highlights the importance of adequate quality control of these critical surgical instruments. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Scaled multiple holes suction tip for microneurosurgery; Technical note

    Directory of Open Access Journals (Sweden)

    Abdolkarim Rahmanian, Associate Professor of Neurosurgery

    2017-12-01

    Conclusion: The new suction tip permits easy and precise adjustment of suction power in microneurosirgical operations. Our scaled 3 and 4-hole suction tip is a simple and useful device for controlling the suction power during the microneurosurgeical procedures.

  11. Note: Automated electrochemical etching and polishing of silver scanning tunneling microscope tips.

    Science.gov (United States)

    Sasaki, Stephen S; Perdue, Shawn M; Rodriguez Perez, Alejandro; Tallarida, Nicholas; Majors, Julia H; Apkarian, V Ara; Lee, Joonhee

    2013-09-01

    Fabrication of sharp and smooth Ag tips is crucial in optical scanning probe microscope experiments. To ensure reproducible tip profiles, the polishing process is fully automated using a closed-loop laminar flow system to deliver the electrolytic solution to moving electrodes mounted on a motorized translational stage. The repetitive translational motion is controlled precisely on the μm scale with a stepper motor and screw-thread mechanism. The automated setup allows reproducible control over the tip profile and improves smoothness and sharpness of tips (radius 27 ± 18 nm), as measured by ultrafast field emission.

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Treatments and Therapies Airway Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. ... or caregiver. Older kids and adults can choose ACTs that they can do on their own. Share ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. Most are easy to ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage ... LEGACY GIFT Sponsor a Participant CF Climb CF Cycle for Life Great Strides Xtreme Hike Participate In ...

  17. The development of fabrication techniques for europia/iron cermet tips for coarse-control arms in DIDO and PLUTO

    International Nuclear Information System (INIS)

    Moore, D.A.; Tarrant, E.A.

    1980-11-01

    The applicability of cermet-fabrication techniques to the production of europia/iron cermets for use as coarse-control arm tips in the materials test reactors DIDO and PLUTO has been investigated. Spheroids of europia were prepared by a dry agglomeration process. These were sintered, dispersed in iron powder and pressed into plates; the plates were then sintered to densify the iron matrix. These stages were optimised to produce a strong cermet with a europia density of >= 2.75 g/cm 3 . The uniformity of distribution of the absorber particles was confirmed by radiography, and adequate neutron-absorption worth by measurements carried out in the GLEEP reactor. An outline flow sheet has been prepared for the manufacture of europia/iron cermet plates suitable for use in the tips of DIDO and PLUTO coarse-control arms. (author)

  18. Modeling shoot-tip temperature in the greenhouse environment

    International Nuclear Information System (INIS)

    Faust, J.E.; Heins, R.D.

    1998-01-01

    An energy-balance model is described that predicts vinca (Catharanthus roseus L.) shoot-tip temperature using four environmental measurements: solar radiation and dry bulb, wet bulb, and glazing material temperature. The time and magnitude of the differences between shoot-tip and air temperature were determined in greenhouses maintained at air temperatures of 15, 20, 25, 30, or 35 °C. At night, shoot-tip temperature was always below air temperature. Shoot-tip temperature decreased from 0.5 to 5 °C below air temperature as greenhouse glass temperature decreased from 2 to 15 °C below air temperature. During the photoperiod under low vapor-pressure deficit (VPD) and low air temperature, shoot-tip temperature increased ≈4 °C as solar radiation increased from 0 to 600 W·m -2 . Under high VPD and high air temperature, shoot-tip temperature initially decreased 1 to 2 °C at sunrise, then increased later in the morning as solar radiation increased. The model predicted shoot-tip temperatures within ±1 °C of 81% of the observed 1-hour average shoot-tip temperatures. The model was used to simulate shoot-tip temperatures under different VPD, solar radiation, and air temperatures. Since the rate of leaf and flower development are influenced by the temperature of the meristematic tissues, a model of shoot-tip temperature will be a valuable tool to predict plant development in greenhouses and to control the greenhouse environment based on a plant temperature setpoint. (author)

  19. Tips to Prevent Mosquito Bites

    Science.gov (United States)

    ... discourage mosquitoes, ticks and other biting insects from landing on you. Here are tips for other preventive ... CDC Mosquito Control Methods - NPIC Exit Top of Page Contact Us to ask a question, provide feedback, ...

  20. Evaluation of serum iohexol clearance for use in predicting carboplatin clearance in cats.

    Science.gov (United States)

    Bailey, Dennis B; Rassnick, Kenneth M; Prey, Joshua D; Dykes, Nathan L

    2009-09-01

    To determine whether a glomerular filtration rate (GFR) assay based on serum iohexol clearance can be used to predict carboplatin clearance in cats. 10 cats with tumors. GFR was measured concurrently by use of plasma clearance of technetium Tc 99m-labeled diethylenetriaminepentaacetic acid ((99m)Tc-DTPA) to yield GFR(99mTc-DTPA) and serum clearance of iohexol to yield GFR(Iohexol). A single dose of carboplatin was administered IV as a bolus. Dose was calculated by use of a target value for the area under the plasma platinum concentration-versus-time curve (AUC(Target)) and estimation of platinum clearance (CL(PT)) derived from GFR(99mTc-DTPA) as follows: dose = AUC(Target) x 2.6 x GFR(99mTc-DTPA) x body weight, where AUC(Target) is 2.75 min.mg.mL(-1). Plasma platinum concentrations were measured via atomic absorption spectrophotometry. Values for GFR(99mTc-DTPA) and GFR(Iohexol) were compared by use of least-squares regression and Bland-Altman analysis. Least-squares regression was used to determine whether CL(PT) could be predicted from GFR(99mTc-DTPA) or GFR(Iohexol) (or both). GFR(99mTc-DTPA) and GFR(Iohexol) were strongly correlated (r = 0.90), but GFR(Iohexol) values were significantly larger by a factor of approximately 1.4. Platinum clearance had a significant linear relationship to GFR(99mTc-DTPA) (CL(PT) = 2.5 x GFR(99mTc-DTPA)) and to GFR(Iohexol) (CL(PT) = [1.3 x GFR(Iohexol)] + 1.4). In cats, serum iohexol clearance was an accurate predictor of CL(PT) and can be used to calculate the carboplatin dose as follows: dose = AUC(Target) x ([1.3 x GFR(Iohexol)] + 1.4) x body weight.

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... and Their Families When There's More Than One Person With CF in the Same School Daily Life ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Team Your cystic fibrosis care team includes a group of CF health care professionals who partner with ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  3. Influence of the tip mass on the tip-sample interactions in TM-AFM

    Energy Technology Data Exchange (ETDEWEB)

    Pishkenari, Hossein Nejat, E-mail: nejat@mech.sharif.edu [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of); Meghdari, Ali [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of)

    2011-07-15

    This paper focuses on the influences of the tip mass ratio (the ratio of the tip mass to the cantilever mass), on the excitation of higher oscillation eigenmodes and also on the tip-sample interaction forces in tapping mode atomic force microscopy (TM-AFM). A precise model for the cantilever dynamics capable of accurate simulations is essential for the investigation of the tip mass effects on the interaction forces. In the present work, the finite element method (FEM) is used for modeling the AFM cantilever to consider the oscillations of higher eigenmodes oscillations. In addition, molecular dynamics (MD) is used to calculate precise data for the tip-sample force as a function of tip vertical position with respect to the sample. The results demonstrate that in the presence of nonlinear tip-sample interaction forces, the tip mass ratio plays a significant role in the excitations of higher eigenmodes and also in the normal force applied on the surface. Furthermore, it has been shown that the difference between responses of the FEM and point-mass models in different system operational conditions is highly affected by the tip mass ratio. -- Highlights: {yields} A strong correlation exists between the tip mass ratio and the 18th harmonic amplitude. {yields} Near the critical tip mass ratio a small change in the tip mass may lead to a significant force change. {yields} Inaccuracy of the lumped model depends significantly on the tip mass ratio.

  4. Intra-operative colloid administration increases the clearance of a post-operative fluid load

    DEFF Research Database (Denmark)

    Borup, Tine; Hahn, Robert; Holte, K

    2009-01-01

    using volume kinetics based on the plasma dilution alone. The pre-operative plasma clearance was compared with the post-operative plasma clearance and patients served as their own control. RESULTS: The urinary excretion averaged 350 ml for the pre-operative infusion and 612 ml post-operatively, which...

  5. Microneedles array with biodegradable tips for transdermal drug delivery

    Science.gov (United States)

    Iliescu, Ciprian; Chen, Bangtao; Wei, Jiashen; Tay, Francis E. H.

    2008-12-01

    The paper presented an enhancement solution for transdermal drug delivery using microneedles array with biodegradable tips. The microneedles array was fabricated by using deep reactive ion etching (DRIE) and the biodegradable tips were made to be porous by electrochemical etching process. The porous silicon microneedle tips can greatly enhance the transdermal drug delivery in a minimum invasion, painless, and convenient manner, at the same time; they are breakable and biodegradable. Basically, the main problem of the silicon microneedles consists of broken microneedles tips during the insertion. The solution proposed is to fabricate the microneedle tip from a biodegradable material - porous silicon. The silicon microneedles are fabricated using DRIE notching effect of reflected charges on mask. The process overcomes the difficulty in the undercut control of the tips during the classical isotropic silicon etching process. When the silicon tips were formed, the porous tips were then generated using a classical electrochemical anodization process in MeCN/HF/H2O solution. The paper presents the experimental results of in vitro release of calcein and BSA with animal skins using a microneedle array with biodegradable tips. Compared to the transdermal drug delivery without any enhancer, the microneedle array had presented significant enhancement of drug release.

  6. Clearance Kinetics and Clearance Routes of Molecules From the Suprachoroidal Space After Microneedle Injection.

    Science.gov (United States)

    Chiang, Bryce; Wang, Ke; Ethier, C Ross; Prausnitz, Mark R

    2017-01-01

    To determine clearance kinetics and routes of clearance of molecules from the suprachoroidal space (SCS) of live New Zealand White rabbits. Suprachoroidal space collapse rate and pressure changes after microneedle injection into SCS were determined. Fluorescent fundus images were acquired to determine clearance rates of molecules ranging in size from 332 Da to 2 MDa. Microneedle injections of fluorescein were performed, and samples were taken from various sites over time to determine amount of fluorescein exiting the eye. Clearance transport was modeled theoretically and compared with experimental data. After injection, pressures in SCS and vitreous humor spiked and returned to baseline within 20 minutes; there was no difference between these two pressures. Suprachoroidal space collapse occurred within 40 minutes. One hour after fluorescein injection, 46% of fluorescein was still present in the eye, 15% had transported across sclera, 6% had been cleared by choroidal vasculature, and 4% had exited via leakage pathways. Characteristic clearance time increased in proportion with molecular radius, but total clearance of 2 MDa FITC-dextran was significantly slower (21 days) than smaller molecules. These data generally agreed with predictions from a theoretical model of molecular transport. Guided by experimental data in the context of model predictions, molecular clearance from SCS occurred in three regimes: (1) on a time scale of approximately 10 minutes, fluid and molecules exited SCS by diffusion into sclera and choroid, and by pressure-driven reflux via transscleral leakage sites; (2) in approximately 1 hour, molecules cleared from choroid by blood flow; and (3) in 1 to 10 hours, molecules cleared from sclera by diffusion and convection.

  7. Clearance potential of ITER vacuum vessel activated materials

    International Nuclear Information System (INIS)

    Cepraga, D.G.; Cambi, G.; Frisoni, M.

    2002-01-01

    To demonstrate fusion's environmental attractiveness over the entire life cycle, a waste analysis is mandatory. The clearance is recommended by IAEA for releasing activated solid materials from regulatory control and for waste management policy. The paper focuses on the approach used to support waste analyses for ITER Generic Site Safety Report. The Material Unconditional Clearance Index of all the materials/zones on the equatorial mid-plane of ITER machine have been evaluated, based on IAEA-TECDOC-855. The Bonami-Nitawl-XSDNRPM sequence of the Scale-4.4a code system (using Vitenea-J library) has been firstly used for radiation transport analyses. Then the Anita-2000 code package is used for the activation calculation. The paper presents also, as an example, an application of the clearance indexes estimation for the ITER vacuum vessel materials. The results of the Anita-2000 have been compared with those obtained using the Fispact-99 activation code. (author)

  8. Variable-temperature independently driven four-tip scanning tunneling microscope

    International Nuclear Information System (INIS)

    Hobara, Rei; Nagamura, Naoka; Hasegawa, Shuji; Matsuda, Iwao; Yamamoto, Yuko; Miyatake, Yutaka; Nagamura, Toshihiko

    2007-01-01

    The authors have developed an ultrahigh vacuum (UHV) variable-temperature four-tip scanning tunneling microscope (STM), operating from room temperature down to 7 K, combined with a scanning electron microscope (SEM). Four STM tips are mechanically and electrically independent and capable of positioning in arbitrary configurations in nanometer precision. An integrated controller system for both of the multitip STM and SEM with a single computer has also been developed, which enables the four tips to operate either for STM imaging independently and for four-point probe (4PP) conductivity measurements cooperatively. Atomic-resolution STM images of graphite were obtained simultaneously by the four tips. Conductivity measurements by 4PP method were also performed at various temperatures with the four tips in square arrangement with direct contact to the sample surface

  9. Final Technical Report: Electrohydrodynamic Tip Streaming

    Energy Technology Data Exchange (ETDEWEB)

    Basaran, Osman [Purdue Univ., West Lafayette, IN (United States)

    2016-01-06

    When subjected to strong electric fields, liquid drops and films form conical tips and emit thin jets from their tips. Such electrodydrodynamic (EDH) tip streaming or cone-jetting phenomena, which are sometimes referred to as electrospraying, occur widely in nature, e.g., in ejection of streams of small charged drops from pointed tips of raindrops in thunderclouds, and technology, e.g., in electrospray mass spectrometry or electric field-driven solvent extraction. More recently, EHD cone-jetting has emerged as a powerful technique for direct printing of solar cells, micro- and nano- particle production, and microencapsulation for controlled release. In many of the aforementioned situations, of equal importance to the processes by which one drop disintegrates to form several drops are those by which (a) two drops come together and coalesce and (b) two drops are coupled to form a double droplet system (DDS) or a capillary switch (CS). the main objective of this research program is to advance through simulation, theory, and experiment the breakup, coalescence, and oscillatory dynamics of single and pairs of charged as well as uncharged drops.

  10. Factors contributing to delay in parasite clearance in uncomplicated falciparum malaria in children

    Directory of Open Access Journals (Sweden)

    Sijuade Abayomi

    2010-02-01

    Full Text Available Abstract Background Drug resistance in Plasmodium falciparum is common in many endemic and other settings but there is no clear recommendation on when to change therapy when there is delay in parasite clearance after initiation of therapy in African children. Methods The factors contributing to delay in parasite clearance, defined as a clearance time > 2 d, in falciparum malaria were characterized in 2,752 prospectively studied children treated with anti-malarial drugs between 1996 and 2008. Results 1,237 of 2,752 children (45% had delay in parasite clearance. Overall 211 children (17% with delay in clearance subsequently failed therapy and they constituted 72% of those who had drug failure, i.e., 211 of 291 children. The following were independent risk factors for delay in parasite clearance at enrolment: age less than or equal to 2 years (Adjusted odds ratio [AOR] = 2.13, 95% confidence interval [CI]1.44-3.15, P 50,000/ul (AOR = 2.21, 95% CI = 1.77-2.75, P 20000/μl a day after treatment began, were independent risk factors for delay in clearance. Non-artemisinin monotherapies were associated with delay in clearance and treatment failures, and in those treated with chloroquine or amodiaquine, with pfmdr 1/pfcrt mutants. Delay in clearance significantly increased gametocyte carriage (P Conclusion Delay in parasite clearance is multifactorial, is related to drug resistance and treatment failure in uncomplicated malaria and has implications for malaria control efforts in sub-Saharan Africa.

  11. Tipping Point

    Medline Plus

    Full Text Available ... death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ... tv tip-overs. The force of a large television falling from tipping furniture can be staggering. A ...

  12. Tipping Point

    Medline Plus

    Full Text Available ... and furniture, appliance and tv tip-overs. The force of a large television falling from tipping furniture ... 50 lb. TV falls with about the same force as child falling from the third story of ...

  13. Tipping Point

    Medline Plus

    Full Text Available ... Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture ... about horrible accidents involving young children and furniture, appliance and tv tip-overs. The force of a ...

  14. Impairment of aminopyrine clearance in aspirin-damaged canine gastric mucosa

    International Nuclear Information System (INIS)

    Miller, T.A.; Henagan, J.M.; Loy, T.M.

    1983-01-01

    Using an in vivo canine chambered stomach preparation, the clearance of [ 14 C]aminopyrine across mucosa when intravenously infused and the back-diffusion of this substance from gastric lumen to mucosa when topically applied to gastric epithelium were evaluated in aspirin-damaged gastric epithelium. In mucosa damaged by either 20 mM or 40 mM aspirin, the recovery of [ 14 C]aminopyrine, when topically mixed with acid (pH . 1.1) perfusate solution, was not significantly different from nondamaged control mucosa. In addition, the degree of ''trapping'' of this substance from back-diffusion was not different in damaged mucosa from that observed in nondamaged epithelium. In contrast, when [ 14 C]aminopyrine was intravenously infused, its clearance was significantly impaired in aspirin-damaged mucosa when compared with control studies, as evidenced by the increased ''trapping'' of this substance in injured epithelium. These findings indicate that movement of aminopyrine from plasma to gastric lumen is impaired in damaged epithelium, making the aminopyrine clearance technique an unreliable method to accurately measure absolute gastric blood flow in this experimental setting

  15. Tips for TIPS

    NARCIS (Netherlands)

    Cuijpers, C.F.

    2015-01-01

    The transjugular intrahepatic portosystemic shunt (TIPS) procedure is one of the most technically challenging procedures in interventional radiology. During the procedure, interventional radiologists (IRs) insert very thin and long instruments through a little incision in the patient’s neck. They

  16. CPAP Tips

    Science.gov (United States)

    ... now Try it free Find out why Close CPAP Tips from FDA USFoodandDrugAdmin Loading... Unsubscribe from USFoodandDrugAdmin? ... apnea and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from ...

  17. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  18. Clearance of materials resulting from the use of radionuclides in medicine, industry and research

    International Nuclear Information System (INIS)

    1998-02-01

    It has long been recognized that the use of sources of radiation should be regulated. The recommended regulatory approach is based on a system of notification and authorization exemplified by the IAEA International Basic Safety Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources (BSS). However, some types of radiation source do not meet to be subject to regulatory control because they can only give rise to trivial radiation hazards. Such sources may be exempted or cleared from the requirements of regulatory control. Exemption applies to radiation sources which do not enter the regulatory control regime, while clearance is relevant to radiation sources which were within the regulatory regime but can be released because they present an insignificant risk to health. It is the latter situation which is the subject of this publication. While the emphasis of the report is on providing guidance on the clearance process and on methods for determining clearance leaves, taking account of site specific factors as appropriate, a set of conservatively derived generic clearance levels is also presented. These are expected to be of considerable help to users of small quantities of radionuclides in laboratories and hospitals and their regulators. They can be used, taking due account of the associated notes of caution, as reference levels for determining when clearance is the appropriate option for disposing of the materials

  19. Efficacy of tip cryotherapy in the treatment of idiopathic guttate hypomelanosis (IGH): a randomized, controlled, evaluator-blinded study.

    Science.gov (United States)

    Laosakul, Kulwadee; Juntongjin, Premjit

    2017-05-01

    Idiopathic guttate hypomelanosis (IGH) is a common hypopigmentation affecting a large amount of older population. However, there is no standard treatment. Cryotherapy has been reported as an alternative therapy for years; nevertheless, there is no randomized controlled study to determine its efficacy. To evaluate the efficacy and side effects of tip cryotherapy in IGH treatment. Total 101 lesions were included. Forty-three lesions were treated with cryotherapy and 58 lesions were assigned as control. A single session of tip cryotherapy was delivered and remained for 5 s. Colorimeter was used to measure lesional luminosity at baseline and then monthly until 4 months. Digital photographs were evaluated by two blinded dermatologists. In addition, patients' assessments and side effects were assessed. Mean luminosity scale gradually decreased from baseline. Also, the score of the treated lesions has been significantly lower than that of the control lesions since week 8 (p = .005). At the fourth month, dermatologists' assessment revealed that 82.3% of the treated lesions comparing to only 2% of the control showed more than 75% improvement (p cryotherapy appears to be an effective therapy with minimal adverse effect for IGH.

  20. Antipyrine clearance during experimental and occupational exposure to toluene

    DEFF Research Database (Denmark)

    Døssing, M; Bælum, Jesper; Lundqvist, G R

    1983-01-01

    into four groups. Eighteen printers and 21 controls were exposed to 100 ppm of toluene during 6.5 hours in an exposure chamber. The remaining 18 printers and 18 controls were exposed to 0 ppm of toluene under similar conditions. The salivary clearance of antipyrine was measured immediately after the stay...

  1. CPAP Tips

    Medline Plus

    Full Text Available ... now Try it free Find out why Close CPAP Tips from FDA USFoodandDrugAdmin Loading... Unsubscribe from USFoodandDrugAdmin? ... apnea and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from ...

  2. Decision Assessment of Clearance Level on Radioactive Waste Management

    International Nuclear Information System (INIS)

    Zainus Salimin; Gunandjar

    2007-01-01

    Radioactive waste on the safe level activity containing very small radioactive material gives small radiology influence to the human, it is not necessary to control by regulatory body. The radioactive waste on the safe level activity is safe to release as the common waste. For exemption of the control, it is required the safe activity level limits in which the value of clearance level is fulfilled by regulatory body, however until now it is not decided yet. The exemption decision is obtained if its activity is lower than or same with clearance level based on the annual effective dose receiving by public on the value is lower than or same with 0,01 mSv. The exposure pathways of radioactive waste to the human have important role for determination of clearance level. The decision assessment of clearance level on the radioactive waste management has been done by analysis of radioactive exposure pathways to the human for activities of the disposal and the recycle of solid wastes, also the release of liquid and gas effluent. For solid waste disposal, the exposure pathway was evaluated since the transportation of packed waste from the treatment facility to the disposal facility and during its operation. Exposure pathways for solid waste recycle consist of the pathways for handling and transportation of cleared material to the recycling facility, the fabrication and the utilization of its product. Exposure pathways for liquid and gas releases occur since its releases to the environment up to the human (public) by specific traffic lane. (author)

  3. Fabrication of tungsten tip for scanning tunneling microscope by the lever principle

    International Nuclear Information System (INIS)

    Wang Yang; Wang Huabin; Chinese Academy of Sciences, Beijing; Gong Jinlong; Zhu Dezhang

    2007-01-01

    A novel experimental setup was designed to fabricate tungsten tips for scanning tunneling microscope (STM), based on simple mechanical lever principle. The equipment can quickly separate the tip from electrolyte to avoid the further etching of the fine-shaped tungsten tip. The setup is advantageous for its simplicity over complex electronic control systems. The use result in scanning electron microscope demonstrates that the radius of the tip can reach 50 nm. The tip was applied to scan the surface of highly-oriented pyrolytic graphite, and the results were satisfactory. It is shown that the tip can be used for the scanning of atomically resolved images. (authors)

  4. Tipping Point

    Medline Plus

    Full Text Available ... 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ...

  5. Attosecond-controlled photoemission from metal nanowire tips in the few-electron regime

    KAUST Repository

    Ahn, B.

    2017-02-07

    Metal nanotip photoemitters have proven to be versatile in fundamental nanoplasmonics research and applications, including, e.g., the generation of ultrafast electron pulses, the adiabatic focusing of plasmons, and as light-triggered electron sources for microscopy. Here, we report the generation of high energy photoelectrons (up to 160 eV) in photoemission from single-crystalline nanowire tips in few-cycle, 750-nm laser fields at peak intensities of (2-7.3) × 1012 W/cm2. Recording the carrier-envelope phase (CEP)-dependent photoemission from the nanowire tips allows us to identify rescattering contributions and also permits us to determine the high-energy cutoff of the electron spectra as a function of laser intensity. So far these types of experiments from metal nanotips have been limited to an emission regime with less than one electron per pulse. We detect up to 13 e/shot and given the limited detection efficiency, we expect up to a few ten times more electrons being emitted from the nanowire. Within the investigated intensity range, we find linear scaling of cutoff energies. The nonlinear scaling of electron count rates is consistent with tunneling photoemission occurring in the absence of significant charge interaction. The high electron energy gain is attributed to field-induced rescattering in the enhanced nanolocalized fields at the wires apex, where a strong CEP-modulation is indicative of the attosecond control of photoemission.

  6. Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs

    International Nuclear Information System (INIS)

    Thomson, J.G.; Kerrigan, C.L.

    1991-01-01

    The hydrogen clearance technique has been used for many years by investigators to determine brain blood flow and has been partially validated in this setting using other methods of blood flow measurement. The method has been modified to allow blood flow measurements in skin, but the accuracy of H2 clearance for measuring skin blood flow has not been determined. Multiple blood flow measurements were performed using H2 clearance and radioactive microspheres on skin flaps and control skin in pigs. On 12 pigs, a total of 117 flap and 42 control skin measurements were available for analysis. There was no significant difference between the two techniques in measuring mean control skin blood flow. In skin flaps, H2 clearance was significantly correlated to microsphere-measured blood flow, but it consistently gave an overestimate. Sources of error may include injury to the tissues by insertion of electrodes, consumption of H2 by the electrodes, or diffusion of H2 from the relatively ischemic flap to its well-vascularized bed. Further studies are necessary to determine the cause of this error and to measure the technique's accuracy in skeletal muscle and other flaps

  7. The tipping point: A mathematical model for the profit-driven abandonment of restaurant tipping

    Science.gov (United States)

    Clifton, Sara M.; Herbers, Eileen; Chen, Jack; Abrams, Daniel M.

    2018-02-01

    The custom of voluntarily tipping for services rendered has gone in and out of fashion in America since its introduction in the 19th century. Restaurant owners that ban tipping in their establishments often claim that social justice drives their decisions, but we show that rational profit-maximization may also justify the decisions. Here, we propose a conceptual model of restaurant competition for staff and customers, and we show that there exists a critical conventional tip rate at which restaurant owners should eliminate tipping to maximize profits. Because the conventional tip rate has been increasing steadily for the last several decades, our model suggests that restaurant owners may abandon tipping en masse when that critical tip rate is reached.

  8. 78 FR 22020 - Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of...

    Science.gov (United States)

    2013-04-12

    ... Control Number: 2120-XXXX. Title: Safety Awareness, Feedback, and Evaluation (SAFE) Program. Form Numbers: No FAA forms are associated with this collection. Type of Review: Clearance of a new information... Activities: Requests for Comments; Clearance of New Approval of Information Collection: Safety Awareness...

  9. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  10. Structure and stability of semiconductor tip apexes for atomic force microscopy

    International Nuclear Information System (INIS)

    Pou, P; Perez, R; Ghasemi, S A; Goedecker, S; Jelinek, P; Lenosky, T

    2009-01-01

    The short range force between the tip and the surface atoms, that is responsible for atomic-scale contrast in atomic force microscopy (AFM), is mainly controlled by the tip apex. Thus, the ability to image, manipulate and chemically identify single atoms in semiconductor surfaces is ultimately determined by the apex structure and its composition. Here we present a detailed and systematic study of the most common structures that can be expected at the apex of the Si tips used in experiments. We tackle the determination of the structure and stability of Si tips with three different approaches: (i) first principles simulations of small tip apexes; (ii) simulated annealing of a Si cluster; and (iii) a minima hopping study of large Si tips. We have probed the tip apexes by making atomic contacts between the tips and then compared force-distance curves with the experimental short range forces obtained with dynamic force spectroscopy. The main conclusion is that although there are multiple stable solutions for the atomically sharp tip apexes, they can be grouped into a few types with characteristic atomic structures and properties. We also show that the structure of the last atomic layers in a tip apex can be both crystalline and amorphous. We corroborate that the atomically sharp tips are thermodynamically stable and that the tip-surface interaction helps to produce the atomic protrusion needed to get atomic resolution.

  11. Electrospray synthesis and properties of hierarchically structured PLGA TIPS microspheres for use as controlled release technologies.

    Science.gov (United States)

    Malik, Salman A; Ng, Wing H; Bowen, James; Tang, Justin; Gomez, Alessandro; Kenyon, Anthony J; Day, Richard M

    2016-04-01

    Microsphere-based controlled release technologies have been utilized for the long-term delivery of proteins, peptides and antibiotics, although their synthesis poses substantial challenges owing to formulation complexities, lack of scalability, and cost. To address these shortcomings, we used the electrospray process as a reproducible, synthesis technique to manufacture highly porous (>94%) microspheres while maintaining control over particle structure and size. Here we report a successful formulation recipe used to generate spherical poly(lactic-co-glycolic) acid (PLGA) microspheres using the electrospray (ES) coupled with a novel thermally induced phase separation (TIPS) process with a tailored Liquid Nitrogen (LN2) collection scheme. We show how size, shape and porosity of resulting microspheres can be controlled by judiciously varying electrospray processing parameters and we demonstrate examples in which the particle size (and porosity) affect release kinetics. The effect of electrospray treatment on the particles and their physicochemical properties are characterized by scanning electron microscopy, confocal Raman microscopy, thermogravimetric analysis and mercury intrusion porosimetry. The microspheres manufactured here have successfully demonstrated long-term delivery (i.e. 1week) of an active agent, enabling sustained release of a dye with minimal physical degradation and have verified the potential of scalable electrospray technologies for an innovative TIPS-based microsphere production protocol. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Evaluation of aorto-iliac disease with Doppler ultrasound and isotope clearance techniques

    International Nuclear Information System (INIS)

    Appleberg, M.; Lewis, J.D.

    1975-01-01

    The clearance of 99 mTc from the hamstring muscle compartment of patients with aorto-iliac or iliac disease was examined with the patients at rest and after exercise. The values were compared with those obtained in a group of controls and another group with superficial femoral, or femoropopliteal arterial occlusion. A statistically significant difference in the rate of 99 mTc clearance was found in patients with proximal vascular disease

  13. Activation and clearance of vanadium alloys and beryllium multipliers in fusion reactors

    International Nuclear Information System (INIS)

    Bartenev, S.; Romanovskij, V.; Ciampichetti, A.; Zucchetti, M.; Forrest, R.; Kolbasov, B.; Romanov, P.

    2006-01-01

    Design of fusion reactors includes the development of low-activation materials. V-Cr-Ti alloys are among the candidate structural materials for the first wall and blanket, with the scarce and costly V as the main component. It is worth considering its regeneration and refabrication as well as to avoid its disposal as radioactive waste. However, to do so, it is necessary to bring its radioactivity down to sufficiently low levels. We have two possible goals: · Recycling (within the nuclear industry) for first wall and front blanket components. In that case, contact dose rate must be sufficiently low. · Clearance (release from nuclear regulatory control) for back blanket and backplate components. In that case, the clearance index must be below unity. In fact, for components less exposed to neutron activation, clearance may be reachable, after a conceivable period of decay. Maximum radionuclide concentrations in the alloys allowing their clearance were determined, using new IAEA Clearance Limits. For this purpose, also for less neutron-exposed structures, such as the back part of the blanket and the backplate, clearance is possible only if certain activation products are separated. As for recycling within the nuclear industry of first wall components, also for clearance it turns out that the development of isotope chemical separation techniques is interesting and necessary for our purposes. A suitable method for achieving the required substantial radioactivity reduction of activated V-Cr-Ti alloys is radiochemical extraction reprocessing, Such a technology, permitting to remove metallic activation products from spent materials, was developed and tested experimentally in Russia. Concerning clearance of less activated components, based on the estimated element distribution factors in the extraction and re-extraction processes, and computations, it was shown that the alloy components may be purified from the activation products, using this technology, down to an

  14. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    International Nuclear Information System (INIS)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan; Valencia, Damian N.; Farber, Rachael G.; Gebel, Dana A.; Killelea, Daniel R.

    2015-01-01

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

  15. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    Energy Technology Data Exchange (ETDEWEB)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan; Valencia, Damian N.; Farber, Rachael G.; Gebel, Dana A.; Killelea, Daniel R., E-mail: dkillelea@luc.edu [Department of Chemistry and Biochemistry, Loyola University Chicago, 1068 W. Sheridan Rd., Chicago, Illinois 60660 (United States)

    2015-03-15

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

  16. Technology Tips

    Science.gov (United States)

    Mathematics Teacher, 2004

    2004-01-01

    Some inexpensive or free ways that enable to capture and use images in work are mentioned. The first tip demonstrates the methods of using some of the built-in capabilities of the Macintosh and Windows-based PC operating systems, and the second tip describes methods to capture and create images using SnagIt.

  17. International guidance on clearance criteria for application to materials containing radionuclides

    International Nuclear Information System (INIS)

    Linsley, G.

    1999-01-01

    The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources establish the conditions whereby radiation sources can be released from control. The essential principle behind this concept, termed clearance, is that the risks associated with the released source should be trivially small. The concept has been widely applied and practically applicable clearance levels have been derived for use in regulating the recycling and reuse of materials originating from the nuclear industry. Since materials released from controls may be traded between countries in the same way as any other material, it is necessary to have international agreements on acceptable levels of radioactivity in materials so as to provide a basis for regulating such movements. The International Atomic Energy Agency, in concert with other international bodies, has for many years been engaged in promoting discussions between its Member States in this subject area. International guidance has been produced and discussions are continuing towards reaching a full consensus on internationally accepted clearance levels. (author)

  18. Recent studies of float and stall curves in controlled-clearance deadweight testers with a simple piston.

    Science.gov (United States)

    Newhall, D H; Ogawa, I; Zilberstein, V

    1979-08-01

    The effect of piston rotation speed and fluid viscosity on the performance of free-piston gauges with a controlled clearance was studied as part of an experimental program aiming at the better evaluation of pressure by these primary pressure standards. Calculated effective area is shown to be greatly influenced by both speed of rotation and choice of a fluid. An optimum rpm resulting in the smallest possible uncertainty in effective area should be determined experimentally for each fluid and pressure range involved. When all the pertinent parameters are properly selected an appreciable improvement in accuracy can be achieved.

  19. Evaluation of aorto-iliac disease with Doppler ultrasound and isotope clearance techniques

    Energy Technology Data Exchange (ETDEWEB)

    Appleberg, M [University of the Witwatersrand, Johannesburg (South Africa). Dept. of Surgery; Lewis, J D

    1975-10-04

    The clearance of /sup 99/mTc from the hamstring muscle compartment of patients with aorto-iliac or iliac disease was examined with the patients at rest and after exercise. The values were compared with those obtained in a group of controls and another group with superficial femoral, or femoropopliteal arterial occlusion. A statistically significant difference in the rate of /sup 99/mTc clearance was found in patients with proximal vascular disease.

  20. Rational customs clearance technology choice

    OpenAIRE

    Shramenko, N.; Andriets, V.

    2008-01-01

    Issues concerning cargo delivery efficiencyincrease by choice of rational customs clearance technology have been considered. Three possible variants of customs clearance andmethods which allow to define the most rational version of cargo delivery in international road communication based on main efficiency criteria for definite distance have been presented.

  1. Abnormal norepinephrine clearance and adrenergic receptor sensitivity in idiopathic orthostatic intolerance

    Science.gov (United States)

    Jacob, G.; Shannon, J. R.; Costa, F.; Furlan, R.; Biaggioni, I.; Mosqueda-Garcia, R.; Robertson, R. M.; Robertson, D.

    1999-01-01

    BACKGROUND: Chronic orthostatic intolerance (OI) is characterized by symptoms of inadequate cerebral perfusion with standing, in the absence of significant orthostatic hypotension. A heart rate increase of >/=30 bpm is typical. Possible underlying pathophysiologies include hypovolemia, partial dysautonomia, or a primary hyperadrenergic state. We tested the hypothesis that patients with OI have functional abnormalities in autonomic neurons regulating cardiovascular responses. METHODS AND RESULTS: Thirteen patients with chronic OI and 10 control subjects underwent a battery of autonomic tests. Systemic norepinephrine (NE) kinetics were determined with the patients supine and standing before and after tyramine administration. In addition, baroreflex sensitivity, hemodynamic responses to bolus injections of adrenergic agonists, and intrinsic heart rate were determined. Resting supine NE spillover and clearance were similar in both groups. With standing, patients had a greater decrease in NE clearance than control subjects (55+/-5% versus 30+/-7%, Pheart rate 25 bpm was lower in patients than in control subjects (0.5+/-0.05 versus 1.0+/-0.1 microg, Pheart rate was similar in both groups. CONCLUSIONS: The decreased NE clearance with standing, resistance to the NE-releasing effect of tyramine, and increased sensitivity to adrenergic agonists demonstrate dramatically disordered sympathetic cardiovascular regulation in patients with chronic OI.

  2. Effect of clonidine on 22Na clearance in the rabbit eye

    International Nuclear Information System (INIS)

    Obenberger, J.; Rozsival, P.; Babicky, A.

    1979-01-01

    Effects of clonidine on the intraocular hydrodynamics demonstrated themselves as changes of 22 Na-clearance. This test is based on the principle of the intraocular penetration of contactly applied radioisotope and on monitoring the decreasing ocular radioactivity by means of external gamma detectors. The half-times of 22 Na-clearance were significantly prolonged after the local application of 100 μl of 0.5% clonidine (Isoglaucon Boehringer) as compared with the control group. The control animals displayed a half-time of 38.0+-2.7 in comparison with the treated animals measured at intervals of 30 to 90 min and 90 to 150 min after drug instillation, where half-times were significantly prolonged to 49.3+-4.3 and 63.4+-3.8, respectively. In other groups of rabbits 22 Na-clearance was measured on the contralateral eyes of after the intravenous injection of clonidine (25 μg per kg). In both cases the half-times did not significantly differ from the values found in controls. The observed changes of ocular hydrodynamics caused by clonidine probably reflect the inhibitory influence of this drug on aqueous humour production. Results of present investigations point to the decisive role of the local action of clonidine on the eye. (author)

  3. 7 CFR 1927.55 - Title clearance services.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS TITLE CLEARANCE AND LOAN CLOSING Real Estate Title Clearance and Loan Closing § 1927.55 Title clearance services. (a) Responsibilities of closing agents. Services to be provided to the agency and the borrower by a closing agent in connection with the transaction vary depending on whether a title insurance...

  4. Relationship between silicon concentration and creatinine clearance

    International Nuclear Information System (INIS)

    Miura, Y.; Nakai, K.; Itoh, C.; Horikiri, J.; Sera, K.; Sato, M.

    1998-01-01

    Silicon levels in dialysis patients are markedly increasing. Using PIXE we determined the relationship between silicon concentration and creatinine clearance in 30 samples. Urine silicon concentration were significantly correlated to creatinine clearance (p<0.001). And also serum silicon concentration were significantly correlated to creatinine clearance (p<0.0001). (author)

  5. The TIPS Liquidity Premium

    DEFF Research Database (Denmark)

    Andreasen, Martin Møller; Christensen, Jens H.E.; Simon Riddell, Simon

    We introduce an arbitrage-free term structure model of nominal and real yields that accounts for liquidity risk in Treasury inflation-protected securities (TIPS). The novel feature of our model is to identify liquidity risk from individual TIPS prices by accounting for the tendency that TIPS, lik...

  6. Retention and clearance of C-11 palmitic acid in ischemic and reperfused canine myocardium

    International Nuclear Information System (INIS)

    Schwaiger, M.; Schelbert, H.R.; Keen, R.; Vinten-Johansen, J.; Hansen, H.; Selin, C.; Barrio, J.; Huang, S.C.; Phelps, M.E.

    1985-01-01

    Free fatty acids are the major energy source for cardiac muscle. Oxidation of fatty acid decreases or even ceases during ischemia. Its recovery after transient ischemia remains largely unexplored. Using intracoronary carbon-11 palmitic acid as a tracer of myocardial fatty acid metabolism in an open chest dog model, retention and clearance of tracer in myocardium were evaluated at control, during ischemia and after reperfusion following a 20 minute occlusion of the left anterior descending coronary artery. Myocardial C-11 time-activity curves were analyzed with biexponential curve-fitting routines yielding fractional distribution and clearance half-times of C-11 palmitic acid in myocardial tissue. In animals with permanent occlusion and intracoronary injection of C-11 palmitic acid distal to the occlusion site, the relative size and half-time of the early clearance curve component differed markedly from control values and did not change with ongoing ischemia. Conversely, in animals with only 20 minutes of coronary occlusion, the relative size of the early C-11 clearance phase was still significantly depressed at 20 and 90 minutes of reperfusion but returned to control level at 180 minutes. Tissue C-11 clearance half-times remained significantly prolonged throughout the reperfusion period. Regional function in reperfused myocardium monitored with ultrasonic crystals recovered slowly and was still less than control after 3 hours of reperfusion. The data indicate that after transient ischemia, myocardial fatty acid metabolism fails to recover immediately. Because the metabolic recovery occurs in parallel with recovery of regional function, C-11 palmitic acid in conjunction with positron tomography may be useful for studying regional fatty acid metabolism noninvasively after an ischemic injury, and may be helpful in identifying reversible tissue injury

  7. THE ROLE OF TIPPING IN REDUCING LABOUR COSTS: CASE OF SECTOR RETAIL PETROLEUM PRODUCTS

    Directory of Open Access Journals (Sweden)

    Andrej Raspor

    2014-05-01

    Full Text Available The purpose of this paper was to determine whether tipping could reduce labour costs in the petroleum products retail sector. The research we present was designed on the basis of survey results gathered from Slovenian petrol stations in 2009 and 2010. We have identified the following factors in the tipping process: job satisfaction, flexibility, service quality, satisfaction, motivation and the factor of receiving tips. The analysis showed correlation between methods used to increase the value of tips and better service quality, increased financial and numerical flexibility, motivation, satisfaction upon receipt of tips and the method used to increase the value of tips. In order to decrease labour costs we propose that the management take control of tipping and integrates tips into the reward system. Also, the employees should be made aware about how tipping improves service and increases their income.

  8. AERODYNAMICS OF WING TIP SAILS

    Directory of Open Access Journals (Sweden)

    MUSHTAK AL-ATABI

    2006-06-01

    Full Text Available Observers have always been fascinated by soaring birds. An interesting feature of these birds is the existence of few feathers extending from the tip of the wing. In this paper, small lifting surfaces were fitted to the tip of a NACA0012 wing in a fashion similar to that of wing tip feathers. Experimental measurements of induced drag, longitudinal static stability and trailing vortex structure were obtained.The tests showed that adding wing tip surfaces (sails decreased the induced drag factor and increased the longitudinal static stability. Results identified two discrete appositely rotated tip vortices and showed the ability of wing tip surfaces to break them down and to diffuse them.

  9. Energy efficient engine high pressure turbine test hardware detailed design report

    Science.gov (United States)

    Halila, E. E.; Lenahan, D. T.; Thomas, T. T.

    1982-01-01

    The high pressure turbine configuration for the Energy Efficient Engine is built around a two-stage design system. Moderate aerodynamic loading for both stages is used to achieve the high level of turbine efficiency. Flowpath components are designed for 18,000 hours of life, while the static and rotating structures are designed for 36,000 hours of engine operation. Both stages of turbine blades and vanes are air-cooled incorporating advanced state of the art in cooling technology. Direct solidification (DS) alloys are used for blades and one stage of vanes, and an oxide dispersion system (ODS) alloy is used for the Stage 1 nozzle airfoils. Ceramic shrouds are used as the material composition for the Stage 1 shroud. An active clearance control (ACC) system is used to control the blade tip to shroud clearances for both stages. Fan air is used to impinge on the shroud casing support rings, thereby controlling the growth rate of the shroud. This procedure allows close clearance control while minimizing blade tip to shroud rubs.

  10. Long-term clearance from small airways in subjects with ciliary dysfunction

    Directory of Open Access Journals (Sweden)

    Hjelte Lena

    2006-05-01

    Full Text Available Abstract The objective of this study was to investigate if long-term clearance from small airways is dependent on normal ciliary function. Six young adults with primary ciliary dyskinesia (PCD inhaled 111 Indium labelled Teflon particles of 4.2 μm geometric and 6.2 μm aerodynamic diameter with an extremely slow inhalation flow, 0.05 L/s. The inhalation method deposits particles mainly in the small conducting airways. Lung retention was measured immediately after inhalation and at four occasions up to 21 days after inhalation. Results were compared with data from ten healthy controls. For additional comparison three of the PCD subjects also inhaled the test particles with normal inhalation flow, 0.5 L/s, providing a more central deposition. The lung retention at 24 h in % of lung deposition (Ret24 was higher (p 24 with slow inhalation flow was 73.9 ± 1.9 % compared to 68.9 ± 7.5 % with normal inhalation flow in the three PCD subjects exposed twice. During day 7–21 the three PCD subjects exposed twice cleared 9 % with normal flow, probably representing predominantly alveolar clearance, compared to 19 % with slow inhalation flow, probably representing mainly small airway clearance. This study shows that despite ciliary dysfunction, clearance continues in the small airways beyond 24 h. There are apparently additional clearance mechanisms present in the small airways.

  11. Pulmonary epithelial clearance of 99mTc-DTPA after thrombin-induced pulmonary microembolism

    International Nuclear Information System (INIS)

    Cooper, J.A.; Feustel, P.J.; Line, B.R.; Malik, A.B.

    1986-01-01

    We investigated the effect of thrombin-induced pulmonary microembolism on the pulmonary clearance rate of aerosolized 99mTc diethylenetriamine pentaacetic acid (99mTc-DTPA) in awake, chronically prepared sheep. Chest activity was recorded after administration of a 0.44 micron aerosol of 99mTc-DTPA. Decay-corrected data were fit to an exponential and expressed as percent decrease per min (%/min). Sheep were given alpha-thrombin intravenously (80 U/kg for 10 min) 60 min after the aerosol administration. The clearance rate prior to alpha-thrombin was 0.35 +/- 0.05 %/min (mean +/- SEM). During alpha-thrombin administration, the clearance rate increased to 5.84 +/- 0.70 %/min (p less than 0.001 from baseline), but returned to 0.41 +/- 0.06 %/min within 30 min after the end of the thrombin infusion. The increased clearance rate during alpha-thrombin administration was not due to increased lung volume since alpha-thrombin did not change functional residual capacity. Moreover, the clearance rate was unchanged during gamma-thrombin administration, which does not induce coagulation, or during alpha-thrombin challenge in defibrinogenated animals. alpha-thrombin administration in neutrophil-depleted sheep caused a transient increase in DTPA clearance similar to that in control sheep, suggesting that the increase occurred independently of neutrophils. The results indicate that alpha-thrombin causes a large, transient increase in 99mTc-DTPA clearance, which may be the result of increased epithelial permeability. This response is dependent on the activation of intravascular coagulation

  12. Regulation Concepts for Clearance Level of Radionuclide in Solid Materials

    International Nuclear Information System (INIS)

    Nanang Triagung Edi Hermawan

    2008-01-01

    Practices of nuclear energy have expanded in some fields such as researches and development, educations, agricultures, medicines and industries. Every practice beside give much benefit, could generate residue or waste. Radioactive waste needs management to ensure the safety of workers, member of the public, and for the eternal of environment. The product of radioactive waste management, in generally, is some containment of radionuclide concentration in solid matrix material after immobilization or conditioning process. Some kind of processed radioactive wastes with short half live then decay faster to stabile condition. The decay will reach clearance level in sometimes, so from the radiation protection views is harmless. This materials above didn’t need control and must be cleared from all determinate and regulation aspects of radioactive material practices. There is clearance for harmless material off course will be simplify management task and efficiency of money. So the regulation about clearance levels will be important as law basic for technical practices in field. (author)

  13. A model of clearance rate regulation in mussels

    Science.gov (United States)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  14. Computational Investigation of Novel Tip Leakage Mitigation Methods for High Pressure Turbine Blades

    Science.gov (United States)

    Ibrahim, Mounir; Gupta, Abhinav; Shyam, Vikram

    2014-01-01

    This paper presents preliminary findings on a possible approach to reducing tip leakage losses. In this paper a computational study was conducted on the Energy Efficient Engine (EEE) High Pressure Turbine (HPT) rotor tip geometry using the commercial numerical solver ANSYS FLUENT. The flow solver was validated against aerodynamic data acquired in the NASA Transonic Turbine Blade Cascade facility. The scope of the ongoing study is to computationally investigate how the tip leakage and overall blade losses are affected by (1) injection from the tip near the pressure side, (2) injection from the tip surface at the camber line, and (3) injection from the tip surface into the tip separation bubble. The objective is to identify the locations on the tip surface at which to place appropriately configured blowing keeping in mind the film cooling application of tip blowing holes. The validation was conducted at Reynolds numbers of 85,000, 343,000, and 685,000 and at engine realistic flow conditions. The coolant injection simulations were conducted at a Reynolds number of 343,000 based on blade chord and inlet velocity and utilized the SST turbulence model in FLUENT. The key parameters examined are the number of jets, jet angle and jet location. A coolant to inlet pressure ratio of 1.0 was studied for angles of +30 deg, -30 deg, and 90 deg to the local free stream on the tip. For the 3 hole configuration, 3 holes spaced 3 hole diameters apart with length to diameter ratio of 1.5 were used. A simulation including 11 holes along the entire mean camber line is also presented (30 deg toward suction side). In addition, the effect of a single hole is also compared to a flat tip with no injection. The results provide insight into tip flow control methods and can be used to guide further investigation into tip flow control. As noted in past research it is concluded that reducing leakage flow is not necessarily synonymous with reducing losses due to leakage.

  15. Insulin resistance and delayed clearance of peptide hormones in cirrhotic rat liver

    International Nuclear Information System (INIS)

    Shankar, T.P.; Drake, S.; Solomon, S.S.

    1987-01-01

    Clearance of porcine insulin, glucagon, and human growth hormone was measured in intact perfused cirrhotic and normal rat livers. Binding and degradation of 125 I-insulin by hepatocytes isolated from cirrhotic and normal livers were also studied. The half-lives (t/sub 1/2/) of immunoreactive insulin and glucagon were 14.0 +/- 3.1 and 9.6 +/- 2.1 min in normal livers and 26.0 +/- 6.1 and 25.0 +/- 7.1 min in cirrhotic livers. Insulin binding and degradation by hepatocytes from control and cirrhotic livers showed no significant differences. Intraportal insulin infusion in perfusion studies suppressed glucagon-stimulated increases in glucose output from control livers but failed to suppress glucose production by cirrhotic livers, suggesting the presence of hepatic insulin resistance in cirrhosis. Impaired clearance of insulin and glucagon by the intact cirrhotic liver and normal binding and degradation of insulin by isolated hepatocytes suggest that factors such as intrahepatic fibrosis and shunting and postbinding defects may be responsible for the impaired hormone clearance and hepatic insulin resistance

  16. Design and performance of a beetle-type double-tip scanning tunneling microscope

    International Nuclear Information System (INIS)

    Jaschinsky, Philipp; Coenen, Peter; Pirug, Gerhard; Voigtlaender, Bert

    2006-01-01

    A combination of a double-tip scanning tunneling microscope with a scanning electron microscope in ultrahigh vacuum environment is presented. The compact beetle-type design made it possible to integrate two independently driven scanning tunneling microscopes in a small space. Moreover, an additional level for coarse movement allows the decoupling of the translation and approach of the tunneling tip. The position of the two tips can be controlled from the millimeter scale down to 50 nm with the help of an add-on electron microscope. The instrument is capable of atomic resolution imaging with each tip

  17. A method to control the fabrication of etched optical fiber probes with nanometric tips

    International Nuclear Information System (INIS)

    Tao, Miaomiao; Gu, Ning; Huang, Lan; Jin, Yonglong

    2010-01-01

    Optical fiber probes with small size tips have attracted much interest in the areas of biosensor and near-field scanning optical microscopy. Chemical etching is a common useful method to fabricate such probes. But it is difficult to study or determine the etching time and control the shape of the fiber during the etching. In this work, a new method combining a fiber optic spectrometer with static chemical etching has been developed to fabricate optical fiber probe nanotips, where the fiber optic spectrometer is used to measure the optical signal during the etching. By calculating and analyzing the testing data, the relationship between the apex angle and the optical signal can be obtained. Accordingly, the process of fabricating optical fibers based on the optical signal can be controlled

  18. Predicting Human Clearance of OATP substrates using Cynomolgus monkey: In vitro-in vivo scaling of hepatic uptake clearance.

    Science.gov (United States)

    de Bruyn, Tom; Ufuk, Ayse; Cantrill, Carina; Kosa, Rachel E; Bi, Yi-An; Niosi, Mark; Modi, Sweta; Rodrigues, A David; Tremaine, Larry M; Varma, Manthena Vs; Galetin, Aleksandra; Houston, J Brian

    2018-05-02

    This work explores the utility of the cynomolgus monkey as a preclinical model to predict hepatic uptake clearance mediated by organic anion transporting polypeptide (OATP) transporters. Nine OATP substrates (rosuvastatin, pravastatin, repaglinide, fexofenadine, cerivastatin, telmisartan, pitavastatin, bosentan and valsartan) were investigated in plated cynomolgus monkey and human hepatocytes. Total uptake clearance and passive diffusion were measured in vitro from initial rates in the absence and presence of the OATP inhibitor rifamycin SV, respectively. Total uptake clearance values in plated hepatocytes ranged over three orders of magnitude in both species with a similar rank order and good agreement in the relative contribution of active transport to total uptake between cynomolgus monkey and human. In vivo hepatic clearance for these nine drugs was determined in cynomolgus monkey after intravenous dosing. Hepatic clearances showed a similar range to human parameters and good predictions from respective hepatocyte parameters (with 2.7 and 3.8-fold bias on average, respectively). The use of cross species empirical scaling factors (based on either dataset average or individual drug scaling factor from cynomolgus monkey data) improved prediction (less bias, better concordance) of human hepatic clearance from human hepatocyte data alone. In vitro intracellular binding in hepatocytes also correlated well between species. It is concluded that the minimal species differences observed for the current dataset between cynomolgus monkey and human hepatocyte uptake, both in vitro and in vivo, support future use of this preclinical model to delineate drug hepatic uptake and enable prediction of human in vivo intrinsic hepatic clearance. The American Society for Pharmacology and Experimental Therapeutics.

  19. 48 CFR 801.602-76 - Business clearance review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... GENERAL DEPARTMENT OF VETERANS AFFAIRS ACQUISITION REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a...

  20. Emergency TIPS in a Child-Pugh B patient

    DEFF Research Database (Denmark)

    Trebicka, Jonel

    2017-01-01

    Transjugular intrahepatic portosystemic shunt (TIPS) is used to treat complications of cirrhosis such as variceal bleeding and refractory ascites, but it also bears the risk of liver failure, overt hepatic encephalopathy (HE) and cardiac decompensation. Variceal bleeding may be controlled using...... translocation. Both these processes mediate an impaired immunological and hemodynamic response, thereby facilitating the development of acute-on-chronic liver failure (ACLF) and/or death. Similarly, in patients with refractory ascites, TIPS should be used early in treatment to prevent acute kidney injury (AKI...

  1. Clinical assessment of tumor clearance during radiotherapy as a prognostic factor of early glottic carcinoma

    International Nuclear Information System (INIS)

    Inoue, Takehiro; Inoue, T.; Ikeda, H.; Teshima, T.; Murayama, S.

    1992-01-01

    From 1967 through 1985, 358 cases of early glottic carcinoma were treated with telecobalt therapy at the Department of Radiology, Osaka University Medical School. Among 278 cases treated with 2 Gy a day, the tumor response of 262 cases at 40, 50 and 60 Gy were evaluated by direct or indirect laryngoscope. The five-year local control rates of these evaluable cases of T1 and T2 glottic carcinoma were 79% and 70%, respectively. The local control rates of T1 glottic carcinoma with tumor clearance and persistence at 40 Gy were 83% (119/143) and 64% (43/67), and those of T2 cases were 86% (18/21) and 58% (18/31), respectively. The local control rates of the cases with tumor clearance and persistence at 40 Gy were same between T1 and T2 cases. The tumor clearance rates of T1 cases were significantly higher than those of T2 cases (p [de

  2. The active control devices of the size of products based on sapphire measuring tips with three degrees of freedom

    Science.gov (United States)

    Leun, E. V.; Leun, V. I.; Sysoev, V. K.; Zanin, K. A.; Shulepov, A. V.; Vyatlev, P. A.

    2018-01-01

    The article presents the results of the calculation of the load capacity of the active control devices (ACD) sapphire tip, which showed nearly 30-fold margin of safety to shock loads and experimental researches in mechanical contact with 5 cogs cutter 15 mm in diameter rotating with a frequency of 1000 rpm, which confirmed the calculations, determined the surface roughness Rz of the contact area of no more than 0.15 μm. Conditions have been created for recording without distortion of the image through a sapphire tip in contact with the processed article. A ACD design with new functionality is proposed: with one, two and three degrees of freedom of the sapphire tip and allows measuring the taper of the article and measurements on the chord. It is shown that with the implementation of their fixed head like the frame of the gyroscope with the rotations around the axes OY and OZ. It is shown that the rotation of the tip around the axis OX can be replaced more convenient for the implementation of the angular offset of the transferred image due to rotation of the output end of the flexible optical waveguide relative to the input. This makes it possible to reduce the "blurring of the image" during registration of the fast moving product profile when the slope of the recorder lines coincides with the slope of the edges of the image elements of the selected moving elements of the article.

  3. Estimation of 131I hippuran clearance during pregnancy

    International Nuclear Information System (INIS)

    Voigt, R.; Stoll, W.; Zenner, I.; Arndt, J.; Friedrich-Schiller-Univ., Jena

    1979-01-01

    Changes in 131 I hippuran clearance were estimated by a non-catheter method, as well as total clearance and clearance of each kidney, in 43 women at various stages of pregnancy and in 13 non-pregnant women who were not using hormonal contraceptives. The results are demonstrated in graph form. The methods used are described in detail. The procedure for determining clearance in separate kidneys is indicated. It was found that clearance values increased up to the 35th and 26th weeks of pregnancy. The difference between the sides that were found corresponds with the previously known difference in the function of the right and left kidneys and ureters. (orig.) [de

  4. Clearance rate of Mytilus edulis (L.) as a function of current velocity and mussel aggregation

    DEFF Research Database (Denmark)

    Nielsen, Pernille; Vismann, Bent

    2014-01-01

    by current velocities up to 1.4 m/sec, whereas experiments with 3 mussels showed that clearance of the mussels decreased progressively at current velocities greater than 0.2 m/sec, and reached 0 L/h per individual at current velocities greater than 0.6 m/sec. The constant feeding at all current velocities......The aim of the current study was to investigate the effect of water current velocities on the clearance rate of Mytilus edulis when different numbers of mussels were used in the experiments. An automatic setup, which controlled and monitored the algal concentration continually, was used to measure...... the effect of increasing current velocity (0.05-1.4 m/sec) on the M. edulis clearance rate. Clearance rate measurements were performed under constant food concentrations of 3,000 cells/mL of Rhodomonas salina on either 3 mussels or 20 mussels. We found that the clearance rate of 20 mussels was unaffected...

  5. Integrated viral clearance strategies-reflecting on the present, projecting to the future.

    Science.gov (United States)

    Roush, David J

    2018-01-20

    Viral clearance and inactivation are critical steps in ensuring the safety of biological products derived from mammalian cell culture and are a component of an adventitious agent control strategy which spans both upstream and downstream processes. Although these approaches have been sufficient to support the development of biologics to date, the empirical and semi-quantitative nature of the approach leaves some potential gaps. For example, the concept of performing a quantitative risk assessment for the downstream components of virus safety was introduced in ICH Q5A for XMuLV. An ideal future state would be to perform a similar quantitative risk assessment for a range of viruses based on an assessment of potential virus risk in both upstream and downstream processes. This assessment combined with an integrated control strategy (including monitoring) would be extremely beneficial in minimizing potential adventitious agent risks. Significant progress has been achieved towards this goal in the last several years including recent advances in quantification of virus sequences in cell banks (ADVTIG), development of truly modular or generic viral clearance claims for specific unit operations, enhanced controls of upstream media (HTST/nanofiltration) and the use of RVLP for in-process monitoring. The recent shift towards continuous processing has the potential to enhance the criticality of in-line monitoring and the complexity of viral clearance and inactivation (owing to a wide range of potential 'worst case' viral clearance scenarios). However, gaps exist in, firstly, the ability to quantify potential virus risk levels in process streams in real-time, secondly, mechanistic understanding of virus/chromatography media interactions, and thirdly, mechanistic understanding of virus/filter interactions. Some new technologies may also need to be developed to allow for real-time confirmation of virus inactivation and clearance to support process development (both batch and

  6. Safety Tips: Basketball (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Safety Tips: Basketball KidsHealth / For Parents / Safety Tips: Basketball ... make sure they follow these tips. Why Basketball Safety Is Important Fortunately, very few basketball injuries are ...

  7. 14 CFR 1260.63 - Customs clearance and visas.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver). Portal hypertension can also occur in children, although children are much less likely to require a TIPS. ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  9. Functionalization of gold and nanocrystalline diamond atomic force microscope tips for single molecule force spectroscopy

    Science.gov (United States)

    Drew, Michael E.

    The atomic force microscope (AFM) has fueled interest in nanotechnology because of its ability to image surfaces at the nanometer level and act as a molecular force sensor. Functionalization of the surface of an AFM tip surface in a stable, controlled manner expands the capabilities of the AFM and enables additional applications in the fields of single molecule force spectroscopy and nanolithography. Two AFM tip functionalizations are described: the assembly of tripodal molecular tips onto gold AFM tips and the photochemical attachment of terminal alkenes to nanocrystalline diamond (NCD) AFM tips. Two separate tripodal molecules with different linker lengths and a monopodal molecule terminated with biotin were synthesized to attach to a gold AFM tip for single molecule force spectroscopy. The immobilization of these molecules was examined by contact angle measurements, spectroscopic ellipsometry, infrared, and near edge x-ray absorption fine structure (NEXAFS) spectroscopy. All three molecules displayed rupture forces that agreed with previously reported values for the biotin--avidin rupture. The tripodal molecular tip displayed narrower distribution in their force histograms than the monopodal molecular tip. The performance of the tripodal molecular tip was compared to the monopodal molecular tip in single molecule force spectroscopy studies. Over repeated measurements, the distribution of forces for the monopodal molecular tip shifted to lower forces, whereas the distribution for the tripodal molecular tip remained constant throughout. Loading rate dependence and control experiments further indicated that the rupture forces of the tripod molecular tips were specific to the biotin--NeutrAvidin interaction. The second functionalization method used the photochemical attachment of undecylenic acid to NCD AFM tips. The photochemical attachment of undecylenic acid to hydrogen-terminated NCD wafer surfaces was investigated by contact angle measurements, x

  10. Effect of increased surface hydrophobicity via drug conjugation on the clearance of inhaled PEGylated polylysine dendrimers.

    Science.gov (United States)

    Haque, Shadabul; McLeod, Victoria M; Jones, Seth; Fung, Sandy; Whittaker, Michael; McIntosh, Michelle; Pouton, Colin; Owen, David J; Porter, Christopher J H; Kaminskas, Lisa M

    2017-10-01

    PEGylated polylysine dendrimers are attractive and well tolerated inhalable drug delivery platforms that have the potential to control the release, absorption kinetics and lung retention time of conjugated drugs. The clinical application of these systems though, would likely require partial substitution of surface PEG groups with drug molecules that are anticipated to alter their lung clearance kinetics and clearance pathways. In the current study, we therefore evaluated the impact of increased surface hydrophobicity via substitution of 50% surface PEG groups with a model hydrophobic drug (α-carboxyl OtButylated methotrexate) on the lung clearance of a Generation 5 PEGylated polylysine dendrimer in rats. PEG substitution with OtBu-methotrexate accelerated lung clearance of the dendrimer by increasing polylysine scaffold catabolism, improving systemic absorption of the intact dendrimer and low molecular weight products of scaffold catabolism, and enhancing mucociliary clearance. These results suggest that the conjugation of hydrophobic drug on the surface of a PEGylated dendrimer is likely to accelerate lung clearance when compared to a fully PEGylated dendrimer. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  11. Windows 7 Annoyances Tips, Secrets, and Solutions

    CERN Document Server

    Karp, David

    2010-01-01

    Windows 7 may be faster and more stable than Vista, but it's a far cry from problem-free. David A. Karp comes to the rescue with the latest in his popular Windows Annoyances series. This thorough guide gives you the tools you need to fix the troublesome parts of this operating system, plus the solutions, hacks, and timesaving tips to make the most of your PC. Streamline Windows Explorer, improve the Search tool, eliminate the Green Ribbon of Death, and tame User Account Control promptsExplore powerful Registry tips and tools, and use them to customize every aspect of Windows and solve its sho

  12. Total Telephone Tips.

    Science.gov (United States)

    Corder, Lloyd E.; And Others

    This manual of telephone behavior tips for business and sales professionals offers ways to handle the disgruntled caller and makes suggestions on topics relevant to the telephone. The manual is divided into the following sections and subsections: (1) Common Courtesy (staff tips, answering the telephone, screening calls, transferring calls, taking…

  13. The effect of full coverage winglets on tip leakage aerodynamics over the plane tip in a turbine cascade

    International Nuclear Information System (INIS)

    Lee, Sang Woo; Cheon, Joo Hong; Zhang, Qiang

    2014-01-01

    Highlights: • The effect of full coverage (FC) winglets on tip leakage aerodynamics is tested. • A qualitative tip gap flow model for the FC winglet is suggested. • The FC winglet of w/p = 10.55% is considered an optimal one for the plane tip. -- Abstract: The effect of full coverage (FC) winglets on tip leakage aerodynamics over the plane tip in a turbine cascade has been investigated with the variation of winglet width (w) up to w/p = 15.83% for a tip gap-to-span (chord) ratio of h/s = 1.36% (h/c = 2.0%). A qualitative tip gap flow model for the FC winglet is suggested on the bases of the near-tip surface flow visualizations. As w/p increases, the passage vortex tends to be weakened meanwhile the tip leakage vortex becomes stronger and wall-jet-like. With an increment of w/p, the mass-averaged aerodynamic loss all over the measurement plane decreases steeply up to w/p = 10.55% and then becomes almost unchanged. Thus, the FC winglet of w/p = 10.55% is considered an optimal one for the plane tip. With respect to the baseline plane tip without winglet, the maximum mass-averaged loss reduction by installing the FC winglet on the plane tip is still somewhat smaller than that by employing the cavity squealer rim on the plane tip surface

  14. The provision of clearances accuracy in piston - cylinder mating

    Science.gov (United States)

    Glukhov, V. I.; Shalay, V. V.

    2017-08-01

    The paper is aimed at increasing the quality of the pumping equipment in oil and gas industry. The main purpose of the study is to stabilize maximum values of productivity and durability of the pumping equipment based on the selective assembly of the cylinder-piston kinematic mating by optimization criterion. It is shown that the minimum clearance in the piston-cylinder mating is formed by maximum material dimensions. It is proved that maximum material dimensions are characterized by their own laws of distribution within the tolerance limits for the diameters of the cylinder internal mirror and the outer cylindrical surface of the piston. At that, their dispersion zones should be divided into size groups with a group tolerance equal to half the tolerance for the minimum clearance. The techniques for measuring the material dimensions - the smallest cylinder diameter and the largest piston diameter according to the envelope condition - are developed for sorting them into size groups. Reliable control of the dimensions precision ensures optimal minimum clearances of the piston-cylinder mating in all the size groups of the pumping equipment, necessary for increasing the equipment productivity and durability during the production, operation and repair processes.

  15. A probabilistic assessment code system for derivation of clearance levels of radioactive materials. PASCLR user's manual

    International Nuclear Information System (INIS)

    Takahashi, Tomoyuki; Takeda, Seiji; Kimura, Hideo

    2001-01-01

    It is indicated that some types of radioactive material generating from the development and utilization of nuclear energy do not need to be subject regulatory control because they can only give rise to trivial radiation hazards. The process to remove such materials from regulatory control is called as 'clearance'. The corresponding levels of the concentration of radionuclides are called as 'clearance levels'. In the Nuclear Safety Commission's discussion, the deterministic approach was applied to derive the clearance levels, which are the concentrations of radionuclides in a cleared material equivalent to an individual dose criterion. Basically, realistic parameter values were selected for it. If the realistic values could not be defined, reasonably conservative values were selected. Additionally, the stochastic approaches were performed to validate the results which were obtained by the deterministic calculations. We have developed a computer code system PASCLR (Probabilistic Assessment code System for derivation of Clearance Levels of Radioactive materials) by using the Monte Carlo technique for carrying out the stochastic calculations. This report describes the structure and user information for execution of PASCLR code. (author)

  16. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...

  17. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  18. Clearance Laboratory - Capability and measurement sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-08-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  19. Clearance Laboratory - Capability and measurement sensitivity

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-09-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  20. An IPMC microgripper with integrated actuator and sensing for constant finger-tip displacement

    International Nuclear Information System (INIS)

    Gonzalez, Carlos; Lumia, Ron

    2015-01-01

    Ionic polymer metal composite (IPMC) is a type of smart material that has gained the interest of many researchers due to its ability to achieve large displacements under small input voltages, usually less than 2.5 V. This has motivated the use of these materials in microsystems and systems in the millimeter scale, such as microgrippers. However, few of the control techniques developed thus far have considered the feasibility of using IPMCs in closed loop systems without the need of oversized external sensors. This paper presents a control scheme for a two-finger IPMC microgripper that accomplishes constant finger-tip displacements without external sensors. This scheme generates a displacement-dependent, time varying reference signal to obtain constant finger-tip displacements applied by a separate actuated IPMC. This actuator uses a PID controller tuned with a model-free approach, and is gain scheduled to span up to 1 mm finger-tip displacements. The microgripper achieves zero steady state error for finger-tip displacements on the tuned values of the PID controller. The gain scheduled PID controller is tested and results show zero steady state error to 0.25 mm displacements, and 15 and 20% steady state error when referenced to deflection of 0.45 and 0.75 mm, respectively. This shows that there is great confidence and validity of the control scheme, especially when tracking small reference deflections. (paper)

  1. The UK Nuclear Industry Code of Practice on Clearances and Exemptions

    International Nuclear Information System (INIS)

    Owen, D.

    2004-01-01

    In 2001, the major nuclear organisations in the United Kingdom started development of a document that would identify and facilitate consistent the application of good practice within the industry for clearing and sentencing of articles, substances and wastes which may be clean, or radioactive at very low levels below thresholds of regulatory control. The document includes: (i) Clarification of the industry's interpretation of legislation associated with the clearance and sentencing of articles, substances and wastes which are or have the potential to have been contaminated by radioactivity or activated by nuclear radiations; (ii) Industry agreement on what is considered to be the good practice where legislation is imprecise or unclear, (iii) A standard management framework, adopted by all organisations within the nuclear industry, that should justify safe and efficient clearance of potentially radioactive articles, substances and wastes; and (IV) Agreed guidance on the principles, processes and practices which should be followed for clearances and sentencing The Document mandates a system that allows articles and substances to be released from further control, where this is appropriate, using robust radiological protection principles. The need to avoid sentencing of clean materials as radioactive waste where this is not appropriate, the primacy of bulk, rather than surface radioactivity clearance criteria, and the need to disallow such clearances until all relevant legislation has been satisfied, are all clear principles contained within the document. An interim issue of the Code of Practice was issued in May 2003. This version has been formally adopted by all of the major users of radioactive material in the United Kingdom, and has two main objectives: -Trial use of the concepts at the working level, and - As a basis for further discussion with interested stakeholders. The paper summarises: - How the interim version of the Code of Practice was developed; - The

  2. Gastric clearance of alpha-1-antitrypsin under cimetidine perfusion. New test to detect protein-losing gastropathy

    International Nuclear Information System (INIS)

    Florent, C.; Vidon, N.; Flourie, B.; Carmantrand, A.; Zerbani, A.; Maurel, M.; Bernier, J.J.

    1986-01-01

    Gastric losses of plasma are usually measured with radiolabeled macromolecules. This method is expensive and cumbersome. Direct measurement of exudated plasma proteins are ineffective since proteins are denaturated by acidic gastric juice and pepsin. It was recently shown that albumin measurement after immediate neutralization allowed detection of gastric protein losses, but this method is quite complex and time consuming. We studied alpha 1-antitrypsin and 51Cr-labeled protein clearance in gastric juice during normal saline and cimetidine (1.5 mg/kg/hr) infusion in six healthy volunteers and six patients with exudative gastropathy. alpha 1-Antitrypsin was measurable in all samples during cimetidine infusion: alpha 1-AT and 51Cr losses were significantly correlated (P less than 0.001). The upper limit of gastric alpha 1-AT clearance in controls was 0.86 ml/hr (mean + 2 SD). Using this value, there was no overlapping between patients and controls. The upper limit of 51Cr test was 1.87 ml/hr (mean + 2 SD) in controls but gastric clearance of 51Cr was below this value in one patient. This suggests that the measurement of alpha 1-AT gastric clearance during cimetidine perfusion is a good test to detect an exudative gastropathy. This test is inexpensive and lasts only 3 hr

  3. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... of lithium or influence of osmotic diuresis. 3. Fractional reabsorption of lithium was reduced in most patients with glomerular filtration rates below 25 ml/min. 4. Calculated fractional distal reabsorption of sodium was reduced in most patients with glomerular filtration rates below 50 ml/min. 5. Lithium...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  4. Experience and lessons learnt from clearance in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, Stefan

    2002-01-01

    Clearance is an important corner-stone of waste management in nuclear installations in Germany. It has been practised successfully for around two decades. The importance of clearance can also be judged from the fact that it has been included detailedly in the new German Radiation Protection Ordinance. Currently, there are 19 NPPs and a number of fuel cycle installations in operation in Germany. The main waste quantities, however, arise from the dismantling of NPPs and fuel cycle installations which are currently in decommissioning. As most of the decommissioning projects are targeted for early dismantling instead of safe enclosure, there is already considerable experience with the application of clearance procedures and verification of clearance levels. The German waste management strategy is governed by two options: Clearance of the material (after decontamination and release measurement). After clearance, the material is no longer regarded as radioactive in a legal sense. Final disposal of the material as radioactive waste in a deep geological repository (no near-surface disposal facilities exist or are planned in Germany). A deep geological repository is planned to be operable around 2030. Stefan Thierfeldt described German clearance requirements and lessons learned from their application to decommissioning of power reactors. The great majority of the waste was in fact recycled, although the costs were dominated by the small fraction that had to be disposed of as radioactive waste. Among the lessons learned from the German experience were some revealing insights into the public perception of both clearance and of recycling of material from decommissioning of a nuclear installation

  5. 19 CFR 122.26 - Entry and clearance.

    Science.gov (United States)

    2010-04-01

    ... AIR COMMERCE REGULATIONS Private Aircraft § 122.26 Entry and clearance. Private aircraft, as defined... information as set forth in § 122.22(c), and grants electronic clearance via electronic mail or telephone...

  6. Comparison of renal clearance of 99mTc-DTPA and inulin, 131I-hippurate and PAH as well as of the creatinine clearance in Wistar rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Order of magnitude and standard deviation of 99m Tc-DTPA and 131 I-hippurate slope clearance were analyzed successively in 56 male Wistar rats. The clearance of 99m Tc-DTPA was 17.4 ± 3.43 μl · s -1 (100 g b-w) -1 , of 131 I-hippurate 34.3 ± 7.21 μl · s -1 (100 g b-w) -1 . In 17 rats inulin and PAH clearances were analyzed by steady state method with permanent infusion and 3 to 4 urine collection periods 3 days later. The endogeneous creatinine clearance was determined within the same periods. The 99m Tc-DTPA slope clearance corresponded to the inulin clearance, as well as the hippurate clearance to the PAH clearance. The high filtration fraction calculated from nuclear medicine and chemical clearance methods and the low PAH extraction (42%) let suggest that PAH and hippurate are eliminated only incompletely from plasma in rat kidney and are unsuitable for determination of renal blood supply in rats. The creatinine clearance with 4.7 ± 1.38 μl · s -1 (100 g b-w) -1 was far beneath the clearance of inulin and 99m Tc-DTPA, supposing that creatinine is reabsorbed tubularly in part and the creatinine clearance can not be used for valuation of the GFR in rats. However, for this the 99m Tc-DTPA clearance in Wistar rats seems to be well suited. (author)

  7. Clearance systems in the brain—implications for Alzheimer disease

    Science.gov (United States)

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  8. Clearance systems in the brain-implications for Alzheimer disease.

    Science.gov (United States)

    Tarasoff-Conway, Jenna M; Carare, Roxana O; Osorio, Ricardo S; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J

    2015-08-01

    Accumulation of toxic protein aggregates-amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles-is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood-brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ.

  9. Secretin enhances [14C]erythritol clearance in unanesthetized dogs

    International Nuclear Information System (INIS)

    Lewis, M.H.; Baker, A.L.; Dhorajiwala, J.; Moossa, A.R.

    1982-01-01

    To determine the effect of secretin infusion on clearance of inert markers into bile, unanesthetized dogs fitted with Thomas cannulas received continuous infusions of [ 14 C]erythritol and [ 3 H]inulin throughout study. Taurocholic acid administered sequentially at 9.0, 20.0, and 40.0 mumol/min enhanced [ 14 C]erythritol clearance, and GIH secretin (3 units/min) administered along with TCA (40.0 mumol/min) increased [ 14 C]erythritol clearance from 4.9 +/- 1.2 ml/10 min to 6.8 +/- 1.3 ml/10 min (P less than 0.001), but simultaneously measured [ 3 H]inulin clearance was unaltered. Secretin alone also increased [ 14 C]erythritol clearance but did not alter [ 3 H]inulin clearance. The increase in [ 14 C]erythritol clearance per unit increase in bile flow was less during secretin infusion than TCA. Thus, secretin increases [ 14 C]erythritol transport through restricted channels, probably distal to the canaliculi. [ 14 C]Erythritol may not be an accurate marker for canalicular bile flow in dogs during secretin infusion

  10. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    DEFF Research Database (Denmark)

    Shin, K. W.; Andersen, Poul

    2015-01-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached...

  11. Comparison of renal clearance of 99mTc-DTPA and inulin 131I-hippurate and PAH as well as creatinine clearance in Wistar-rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Averages and standard deviations of 99m Tc-DTPA and 131 I-hippurate slope clearance were consecutively determined for 56 male Wistar rats, with a body-weight of 271 ± 69 g in a single investigation. Clearance of 99m Tc-DTPA was 17.4 ± 3.4, that of 131 I-hippurate was 34.3 ± 7.2 μl · s -1 per 100 g body weight. For 17 rats inulin and PAH clearances were determined after 3 days with the steady-state method with continuous infusion and 3-4 periods of urine collection. During the same periods endogeneous creatinine clearance was determined. 99m Tc-DTPA slope clearance correlated well with inulin clearance, also the hippurate with the PAH clearance. The high values of the filtration fraction, calculated from radioisotope and chemical methods, and the low PAH extraction of 42% lead to the conclusion, that PAH and hippurate are incompletely eliminated by the rat kidney from plasma and therefore are inadequate for determining renal blood flow in rats. Creatinine clearance was 4.7 ± 1.38 μl · s -1 per 100 g body weight, much lower than that of inulin and 99m Tc-DTPA. Therefore is assumed, that tubular reabsorption of creatinine occurs and creatinine clearance cannot serve for the evaluation of GFR in rats. For this, however, the clearance of 99m Tc-DTPA seems well applicable in Wistar rats. (author)

  12. Tips on Blood Testing

    Science.gov (United States)

    ... Test Pain, Discomfort and Anxiety Tips to Help Children through Their Medical Tests Tips to Help the Elderly through Their Medical Tests Find Us On Social Media: Facebook Twitter Google Plus Footer Menu Home About ...

  13. Tip-surface interactions at redox responsive poly(ferrocenylsilane) (PFS) interface by AFM-based force spectroscopy

    International Nuclear Information System (INIS)

    Chung Hongjing; Song Jing; Vancso, G. Julius

    2009-01-01

    Poly(ferrocenylsilanes) (PFS) belong to the class of redox responsive organometallic polymers. Atomic force microscopy (AFM)-based single molecule force spectroscopy (SMFS) was used earlier to study single chain PFS response and redox energy driven single chain PFS molecular motors. Here we present further AFM investigations of force interactions between tip and a grafted PFS surface under potential control in electrochemical redox cycles. Typical tip-Au interaction is considered as reference in the force measurements. First the electrostatic component in the diffused double layer (DL) in NaClO 4 electrolyte environment was considered for a 'grafted to' PFS, which dominated the interplay between the tip and sample surface. The DL forces can also hinder the physisorption of PFS chain onto the tip when the voltage was applied at -0.1 V. On the other hand, if the tip contacted the PFS surface prior to the electrochemical process, physisorption of PFS chains governed the overall interaction regardless of subsequently applied surface potential. In addition, prolonged contact time, t c , may also contribute to the stability of tip-PFS bridging and detection of electrostatic forces between the tip-PFS interface. The results showed that tip-substrate interaction forces without PFS grafts have negligibly small force contributions under similar, electrochemically controlled, conditions used in single PFS chain based molecular motors.

  14. Metabolic clearance rate and urinary clearance of purified beta-core

    International Nuclear Information System (INIS)

    Wehmann, R.E.; Blithe, D.L.; Flack, M.R.; Nisula, B.C.

    1989-01-01

    We injected a highly purified preparation of the beta-core molecule, a fragment of hCG beta excreted in pregnancy urine, into five men and three women to determine its kinetic parameters, MCR, and urinary clearance. The beta-core molecule was distributed in an initial volume [1950 +/- 156 (mean +/- SEM) mL/m2 body surface area] approximately equal to the estimated plasma volume. Its disappearance was multiexponential on a semilogarithmic plot, with a rapid phase t1/2 of 3.5 +/- 0.7 min and a slow phase t1/2 of 22.4 +/- 4.2 min. The transit time (the mean time spent by a molecule of beta-core in transit) was 20.6 +/- 2.1 min. The MCR was 192.0 +/- 8.0 mL/min.m2 body surface area. About 5% of the injected dose of beta-core was excreted into the urine in the first 30 min after injection, and low levels of excretion persisted for up to 7 days. The urinary clearance rate of beta-core was 13.7 +/- 1.4 mL/min.m2, accounting for about 8% of the elimination of beta-core from the plasma. The beta-core immunoreactivity in serum and urine was characterized by gel filtration and three independent RIA systems to show that its properties were indistinguishable from those of the injected beta-core. Serum levels of beta-core in pregnant women were less than 0.2 ng/mL, while the amounts excreted in their urine were as much as 5 mg/day. Based on these clearance parameters of beta-core in normal subjects, less than 0.2% of the beta-core excreted in pregnancy urine is derived by urinary clearance of plasma beta-core. Therefore, more than 99% of the beta-core excreted in pregnancy urine is derived from beta-core in a compartment separate from plasma. In particular, these data indicate that there is relatively little placental secretion of beta-core into plasma and that placental secretion does not account for the vast majority of beta-core in pregnancy urine

  15. Dextran fractional clearance studies in acute dengue infection.

    Directory of Open Access Journals (Sweden)

    Julie Nguyen-Pouplin

    2011-08-01

    Full Text Available Although increased capillary permeability is the major clinical feature associated with severe dengue infections the mechanisms underlying this phenomenon remain unclear. Dextran clearance methodology has been used to investigate the molecular sieving properties of the microvasculature in clinical situations associated with altered permeability, including during pregnancy and in various renal disorders. In order to better understand the characteristics of the vascular leak associated with dengue we undertook formal dextran clearance studies in Vietnamese dengue patients and healthy volunteers.We carried out serial clearance studies in 15 young adult males with acute dengue and evidence of vascular leakage a during the phase of maximal leakage and b one and three months later, as well as in 16 healthy control subjects. Interestingly we found no difference in the clearance profiles of neutral dextran solutions among the dengue patients at any time-point or in comparison to the healthy volunteers.The surface glycocalyx layer, a fibre-matrix of proteoglycans, glycosaminoglycans, and plasma proteins, forms a complex with the underlying endothelial cells to regulate plasma volume within circumscribed limits. It is likely that during dengue infections loss of plasma proteins from this layer alters the permeability characteristics of the complex; physical and/or electrostatic interactions between the dextran molecules and the glycocalyx structure may temporarily restore normal function, rendering the technique unsuitable for assessing permeability in these patients. The implications for resuscitation of patients with dengue shock syndrome (DSS are potentially important. It is possible that continuous low-dose infusions of dextran may help to stabilize the permeability barrier in patients with profound or refractory shock, reducing the need for repeated boluses, limiting the total colloid volume required. Formal clinical studies should help to assess

  16. Swing limb mechanics and minimum toe clearance in people with knee osteoarthritis.

    Science.gov (United States)

    Levinger, Pazit; Lai, Daniel T H; Menz, Hylton B; Morrow, Adam D; Feller, Julian A; Bartlett, John R; Bergman, Neil R; Begg, Rezaul

    2012-02-01

    Knee osteoarthritis (OA) has been shown to be a risk factor for falls. Reductions in foot clearance during the swing phase of walking can cause a trip and potentially lead to a fall. This study examined the swing phase mechanics of people with and without knee OA during walking. Minimum toe clearance (MTC) height, joint angles at the time of MTC and the influence of the angular changes of the hip, knee and ankle of the swing leg on foot clearance using sensitivity analysis were investigated in 50 knee OA participants and 28 age-matched asymptomatic controls. Although both groups had a similar MTC height (controls: 12.8±6.7 mm, knee OA: 13.4±7.0 mm), the knee OA group used a different strategy to achieve the same foot clearance, as evidenced by greater knee flexion (52.5±5.3° vs 49.4±4.8°, p=0.007), greater hip abduction (-3.6±3.3° vs -1.8±3.3°, p=0.03) and less ankle adduction (2.8±1.9° vs 4.2±2.1°, p=0.01). MTC height was comparable between the groups, however a different swing phase mechanism was used by the knee OA. Although adequate MTC is an important component of safe locomotion, it does not appear to be impaired in people with knee OA. Other factors, such as inadequate responses to postural perturbation, may be responsible for falls in this group. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Optical shaping of a nano-scale tip by femtosecond laser assisted field evaporation

    Science.gov (United States)

    Di Russo, E.; Houard, J.; Langolff, V.; Moldovan, S.; Rigutti, L.; Deconihout, B.; Blavette, D.; Bogdanowicz, J.; Vella, A.

    2018-04-01

    We have investigated the morphology of a nanotip under femtosecond laser pulse illumination and a high electric field. We show that both the symmetry and the local radius of the tip change with the direction of laser polarization as against the tip axis. The experiments were performed on the very same GaN nanotip by laser-assisted atom probe tomography and electron tomography. This allowed an accurate assessment of the tip features by following the order of evaporation of single atoms from the surface. A change of atom emission sites was observed when a change of the angle between the tip axis and the linearly polarized electric field of the laser was imposed. This enables an optical control of field-evaporation sites. A close optical control of the tip morphology on a scale below 10 nm is thus achievable. Calculations of the field at nanotip apex and absorption maps support the experimental observations. Based on the present study, methods can be developed for reshaping nanotips at the nanometer level. This finding opens perspectives for numerous applications, making use of nanotips as probes or field emitters, and for plasmonic devices.

  18. Calibration of tip and sample temperature of a scanning tunneling microscope using a superconductive sample

    Energy Technology Data Exchange (ETDEWEB)

    Stocker, Matthias; Pfeifer, Holger; Koslowski, Berndt, E-mail: berndt.koslowski@uni-ulm.de [Institute of Solid State Physics, University of Ulm, D-89069 Ulm (Germany)

    2014-05-15

    The temperature of the electrodes is a crucial parameter in virtually all tunneling experiments. The temperature not only controls the thermodynamic state of the electrodes but also causes thermal broadening, which limits the energy resolution. Unfortunately, the construction of many scanning tunneling microscopes inherits a weak thermal link between tip and sample in order to make one side movable. Such, the temperature of that electrode is badly defined. Here, the authors present a procedure to calibrate the tip temperature by very simple means. The authors use a superconducting sample (Nb) and a standard tip made from W. Due to the asymmetry in the density of states of the superconductor (SC)—normal metal (NM) tunneling junction, the SC temperature controls predominantly the density of states while the NM controls the thermal smearing. By numerically simulating the I-V curves and numerically optimizing the tip temperature and the SC gap width, the tip temperature can be accurately deduced if the sample temperature is known or measureable. In our case, the temperature dependence of the SC gap may serve as a temperature sensor, leading to an accurate NM temperature even if the SC temperature is unknown.

  19. Calibration of tip and sample temperature of a scanning tunneling microscope using a superconductive sample

    International Nuclear Information System (INIS)

    Stocker, Matthias; Pfeifer, Holger; Koslowski, Berndt

    2014-01-01

    The temperature of the electrodes is a crucial parameter in virtually all tunneling experiments. The temperature not only controls the thermodynamic state of the electrodes but also causes thermal broadening, which limits the energy resolution. Unfortunately, the construction of many scanning tunneling microscopes inherits a weak thermal link between tip and sample in order to make one side movable. Such, the temperature of that electrode is badly defined. Here, the authors present a procedure to calibrate the tip temperature by very simple means. The authors use a superconducting sample (Nb) and a standard tip made from W. Due to the asymmetry in the density of states of the superconductor (SC)—normal metal (NM) tunneling junction, the SC temperature controls predominantly the density of states while the NM controls the thermal smearing. By numerically simulating the I-V curves and numerically optimizing the tip temperature and the SC gap width, the tip temperature can be accurately deduced if the sample temperature is known or measureable. In our case, the temperature dependence of the SC gap may serve as a temperature sensor, leading to an accurate NM temperature even if the SC temperature is unknown

  20. Allometric scaling for predicting human clearance of bisphenol A

    International Nuclear Information System (INIS)

    Collet, Séverine H.; Picard-Hagen, Nicole; Lacroix, Marlène Z.; Puel, Sylvie; Viguié, Catherine; Bousquet-Melou, Alain; Toutain, Pierre-Louis; Gayrard, Véronique

    2015-01-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min

  1. Allometric scaling for predicting human clearance of bisphenol A

    Energy Technology Data Exchange (ETDEWEB)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr; Puel, Sylvie, E-mail: s.puel@envt.fr; Viguié, Catherine, E-mail: c.viguie@envt.fr; Bousquet-Melou, Alain, E-mail: a.bousquet-Melou@envt.fr; Toutain, Pierre-Louis, E-mail: pltoutain@wanadoo.fr; Gayrard, Véronique, E-mail: v.gayrard@envt.fr

    2015-05-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.

  2. Controlled deposition of palladium nanodendrites on the tips of gold nanorods and their enhanced catalytic activity.

    Science.gov (United States)

    Su, Gaoxing; Jiang, Huaqiao; Zhu, Hongyan; Lv, Jing-Jing; Yang, Guohai; Yan, Bing; Zhu, Jun-Jie

    2017-08-31

    Plasmonic Au-Pd nanostructures have drawn significant attention for use in heterogeneous catalysis. In this study, palladium nanodendrite-tipped gold nanorods (PdND-T-AuNRs) were subjected to a facile fabrication under mild reaction conditions. The palladium amounts on the two tips were tunable. In the preparation of PdND-T-AuNRs, dense capped AuNRs, a low reaction temperature, and suitable stabilizing agents were identified as critical reaction parameters for controlling palladium nanodendrites deposited on both ends of AuNRs. After overgrowth with palladium nanodendrites, the longitudinal surface plasmonic resonance peaks of PdND-T-AuNRs were red-shifted from 810 nm to 980 nm. The electrocatalytic activity of PdND-T-AuNRs for ethanol oxidation was examined, which was a bit weaker than that of cuboid core-shell Au-Pd nanodendrites; however, PdND-T-AuNRs were more stable in ethanol electrooxidation. Moreover, the photocatalytic activity of PdND-T-AuNRs for Suzuki cross-coupling reactions was investigated. At room temperature, nearly 100% yield was obtained under laser irradiation. The results can further enhance our capability of fine-tuning the optical, electronic, and catalytic properties of the bimetallic Au-Pd nanostructures.

  3. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor... Clauses 2452.237-75 Clearance of contractor personnel. As prescribed in 2437.110(e), insert the following clause in solicitations and contracts. Clearance of Contractor Personnel (OCT 1999) (a) General. This...

  4. Chemically etched fiber tips for near-field optical microscopy: a process for smoother tips.

    Science.gov (United States)

    Lambelet, P; Sayah, A; Pfeffer, M; Philipona, C; Marquis-Weible, F

    1998-11-01

    An improved method for producing fiber tips for scanning near-field optical microscopy is presented. The improvement consists of chemically etching quartz optical fibers through their acrylate jacket. This new method is compared with the previous one in which bare fibers were etched. With the new process the meniscus formed by the acid along the fiber does not move during etching, leading to a much smoother surface of the tip cone. Subsequent metallization is thus improved, resulting in better coverage of the tip with an aluminum opaque layer. Our results show that leakage can be avoided along the cone, and light transmission through the tip is spatially limited to an optical aperture of a 100-nm dimension.

  5. High-Temperature Sensor Based on Fabry-Perot Interferometer in Microfiber Tip

    Directory of Open Access Journals (Sweden)

    Zhenshi Chen

    2018-01-01

    Full Text Available A miniaturized tip Fabry-Perot interferometer (tip-FPI is proposed for high-temperature sensing. It is simply fabricated for the first time by splicing a short length of microfiber (MF to the cleaved end of a standard single mode fiber (SMF with precise control of the relative cross section position. Such a MF acts as a Fabry-Perot (FP cavity and serves as a tip sensor. A change in temperature modifies the length and refractive index of the FP cavity, and then a corresponding change in the reflected interference spectrum can be observed. High temperatures of up to 1000 °C are measured in the experiments, and a high sensitivity of 13.6 pm/°C is achieved. This compact sensor, with tip diameter and length both of tens of microns, is suitable for localized detection, especially in harsh environments.

  6. Tip-induced nanoreactor for silicate

    Science.gov (United States)

    Gao, Ming; Ma, Liran; Liang, Yong; Gao, Yuan; Luo, Jianbin

    2015-09-01

    Nanoscale scientific issues have attracted an increasing amount of research interest due to their specific size-effect and novel structure-property. From macro to nano, materials present some unique chemical reactivity that bulk materials do not own. Here we introduce a facile method to generate silicate with nanoscale control based on the establishment of a confined space between a meso/nanoscale tungsten tip and a smooth silica/silicon substrate. During the process, local water-like droplets deposition can be obviously observed in the confinement between the Si/SiO2 surfaces and the KOH-modified tungsten tip. By the combination of in-situ optical microscopy and Raman spectroscopy, we were able to take a deep insight of both the product composition and the underlying mechanism of such phenomena. It was indicated that such nanoreactor for silicate could be quite efficient as a result of the local capillarity and electric field effect, with implications at both nano and meso scales.

  7. ADHD: Tips to Try

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español ADHD: Tips to Try KidsHealth / For Teens / ADHD: Tips to Try Print en español TDAH: Consejos que puedes probar ADHD , short for attention deficit hyperactivity disorder , is a ...

  8. Development of a Novel System to Measure a Clearance of a Passenger Platform

    Science.gov (United States)

    Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.

    2016-06-01

    Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.

  9. Newborn Care: 10 Tips for Stressed-Out Parents

    Science.gov (United States)

    ... a veteran, consider 10 practical tips to keep stress under control. Resist the urge to count caffeine as a major food group or a substitute for sleep. Instead, eat a healthy diet, drink plenty of water and get some ...

  10. Controlled Ascent From the Surface of an Asteroid

    Science.gov (United States)

    Shen, Haijun; Roithmayr, Carlos M.; Cornelius, David M.

    2014-01-01

    The National Aeronautics and Space Administration (NASA) is currently investigating a conceptual robotic mission to collect a small boulder up to 4 m in diameter resting on the surface of a large Near Earth Asteroid (NEA). Because most NEAs are not well characterized, a great range of uncertainties in boulder mass properties and NEA surface characteristics must be considered in the design of this mission. These uncertainties are especially significant when the spacecraft ascends with the boulder in tow. The most important requirement during ascent is to keep the spacecraft in an upright posture to maintain healthy ground clearances for the two large solar arrays. This paper focuses on the initial stage (the first 50 m) of ascent from the surface. Specifically, it presents a sensitivity study of the solar array ground clearance, control authority, and accelerations at the array tips in the presence of a variety of uncertainties including various boulder sizes, densities, shapes and orientations, locations of the true center of mass, and push-off force distributions. Results are presented, and appropriate operations are recommended in the event some of the off-nominal cases occur.

  11. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations

    International Nuclear Information System (INIS)

    Lindblad, H.G.; Berg, U.B.

    1994-01-01

    The authors have evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin. The clearance of iohexol correlated well with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patient with relatively normal filtration rates. It is concluded that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice. 25 refs., 5 figs

  12. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  13. Security Clearance Tracking System

    Data.gov (United States)

    National Archives and Records Administration — SCTS supports the adjudication process of private background investigations and clearances for potential employees, contractors, interns and student workers.

  14. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    Energy Technology Data Exchange (ETDEWEB)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-10-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure (12 cmH2O continuous positive airway pressure (CPAP)) or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH2O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH2O; clearance and FRC were determined at CPAP of 12 cmH2O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method.

  15. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    International Nuclear Information System (INIS)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-01-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure [12 cmH 2 O continuous positive airway pressure (CPAP)] or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH 2 O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH 2 O; clearance and FRC were determined at CPAP of 12 cmH 2 O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method

  16. Hepatic drug clearance following traumatic injury.

    Science.gov (United States)

    Slaughter, R L; Hassett, J M

    1985-11-01

    Trauma is a complex disease state associated with physiologic changes that have the potential to alter hepatic drug clearance mechanisms. These responses include alterations in hepatic blood flow, reduction in hepatic microsomal activity, reduction in hepatic excretion processes, and changes in protein binding. Hepatic blood flow is influenced by sympathomimetic activity. Both animal and human studies demonstrate an initial reduction and subsequent increase in hepatic blood flow, which coincides with an observed increase and subsequent return to normal in serum catecholamine concentrations. Unfortunately, there are no human studies that address the importance these findings may have to the clearance processes of high intrinsic clearance compounds. Animal studies of trauma indicate that hepatic microsomal activity is depressed during the post-traumatic period. Reduction in the hepatic clearance of antipyrine, a model low intrinsic compound, has also been demonstrated in animal models of trauma. In addition to these effects, hepatic excretion of substances such as indocyanine green and bilirubin have been demonstrated to be impaired in both traumatized animals and humans. Finally, substantial increases in the serum concentration of the binding protein alpha 1-acid glycoprotein occur in trauma patients. This has been reported to be associated with subsequent decreases in the free fraction of lidocaine and quinidine. In addition to changing serum drug concentration/response relationships, the pharmacokinetic behavior of drugs bound to alpha 1-acid glycoprotein should also change. Preliminary observations in our laboratory in a dog model of surgically-induced trauma have shown a reduction in the total clearance of lidocaine and reduction in free lidocaine concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  18. Analysis of conservativity analysis for clearance levels. Final report

    International Nuclear Information System (INIS)

    Deckert, A.; Thierfeldt, S.

    1997-07-01

    When deriving clearance levels for material from nuclear installations it is necessary to proceed with a certain degree of conservativity. This can, however, differ between various sets of clearance levels leading to inconsistencies between clearance pathways. The aim of the work therefore is to compare levels of conservativity for the following two sets of clearance levels: clearance levels for disposal as conventional waste and for metallic materials for recycling/reuse. A method was developed to quantify the degree of conservativity and make it comparable. The actual and future situation for disposal of (conventional) wastes in Germany was analysed. In addition, the masses, nuclide vectors, geographical distribution etc. for slightly radioactive material being cleared for conventional disposal was analysed and modelled and the resulting dose distributions were calculated. The values for the clearance levels were taken from the 1995 recommendation by the German Commission on Radiation Protection (SSK). By using realistic scenarios, the exposure was calculated for the personnel on the landfills and for persons of the general public being exposed via groundwater pathways. It could be shown that the trivial dose range will not be exceeded even if the masses of cleared material per landfill site exceed 100 Mg/a. Because of the types and distribution of nuclear installations in Germany and because of the nuclide vectors it is therefore not necessary to limit the masses per landfill sites. Clearance levels that are determined by the exposure pathways external exposure to and the inhalation of dust by the landfill personnel show a similar level of conservativity as those for metal scrap. This means that the clearance levels for gamma emitting nuclides are not overly restrictive. Although radiologically justified, raising the clearance levels would not lead to an increase of the material quantities because other nuclides of the respective nuclide vectors are limiting. In

  19. Numerical investigation of three wind turbine blade tips

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, J.; Soerensen, N.N.

    2002-08-01

    The complex three-dimensional flow around three different tip shapes on a rotating wind turbine blade is investigated and analyzed using Computational Fluid Dynamics. Differences in production, flap wise bending moments and forces are discussed. A method for determining the local inflow angle of attack is presented and further analysis is performed on lift and drag coefficients. It is shown that the original Standard tip results in a more concentrated tip vortex leading to a steeper gradient on both tangential and normal forces when approaching the tip, whereas the two tapered tips show a more flat behavior. This again leads to lower flap wise bending moments and lower production for the Standard tip compared to the two tapered tips. At 12 m/s, though, the Swept tip shows a separation pattern on the surface. This separation causes a decrease in normal force and an increase in tangential force. The Taper tip keeps the higher loading causing the flap wise bending moment to be higher as seen in measurements. To determine the radial variation of lift and drag coefficients the local inflow angle of attack is determined. It is shown that the Standard tip experiences a slightly larger angle of attack at the tip compared to the two tapered tips. The lift coefficients are kept at a more constant level for the two tapered tips due to the decrease in chord, while the drag coefficients actually decrease for the two tapered tips, especially for the Swept tip. For the Swept tip at 12 m/s both lift and drag coefficients changed considerably due to the separation. Differences in aerodynamic damping of the three tips were investigated using HAWCDAMP. The Standard tip seems to be slightly less damped with respect to the edgewise vibrations. (au)

  20. Numerical investigation of hub clearance flow in a Kaplan turbine

    Science.gov (United States)

    Wu, H.; Feng, J. J.; Wu, G. K.; Luo, X. Q.

    2012-11-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  1. Numerical investigation of hub clearance flow in a Kaplan turbine

    International Nuclear Information System (INIS)

    Wu, H; Feng, J J; Wu, G K; Luo, X Q

    2012-01-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  2. The lateral crural rein flap: a novel technique for management of tip rotation in primary rhinoplasty.

    Science.gov (United States)

    Kuran, Ismail; Öreroğlu, Ali Rıza; Efendioğlu, Kamran

    2014-09-01

    An important consideration in rhinoplasty is maintenance of the applied tip rotation. Different techniques have been proposed to accomplish this. Loss of rotation after surgery not only results in a derotated tip but also can create a supratip deformity. As a supplement to dorsal reconstruction, the authors introduced and applied the lateral crural rein flap technique, whereby cartilage flaps are created from the cephalic portion of the lateral crura to control and stabilize tip rotation. Eleven patients underwent primary open-approach rhinoplasty that included the lateral crural rein technique; the mean follow-up time was 18 months. Excess cephalic portions of the lateral crura were prepared as medial crura-based cartilaginous flaps and were incorporated into the nasal dorsum (similar to spreader grafts) and stabilized to achieve the desired tip rotation. The lateral crural rein flap technique provided stability to the nasal tip while minimizing derotation in the postoperative period. Long-term follow-up revealed maintenance of the nasal tip rotation and symmetric dorsal aesthetic lines. The lateral crural rein flap technique is effective for controlling nasal tip rotation while reducing lateral crural cephalic excess. Longevity of the applied tip rotation is reinforced by secure attachment of the lower nasal cartilage complex to the midvault structures. 4. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  3. Lightning Safety Tips and Resources

    Science.gov (United States)

    ... Services Careers Contact Us Glossary Safety National Program Lightning Safety Tips and Resources Weather.gov > Safety > Lightning Safety Tips and Resources Lightning Resources Lightning strikes ...

  4. Determination of renal clearance of 131I-hippuran

    International Nuclear Information System (INIS)

    Ridzon, S.

    1982-01-01

    The author presents his own method for the determination of total renal clearance of 131 I-hippuran under conditions of its diminishing plasma concentration following single intravenous administration. Total renal clearance is determined as the ratio of the amount of activity excreted into the urine over a certain time interval and of the area limited by the curve of activity decrease in plasma and by the time axis in the corresponding interval. The results are demonstrated in five investigated healthy subjects, and very good agreement of the calculated values of total renal clearance for different time intervals in the same subject is pointed out. When isotope nephrography is simultaneously performed, the method allows to determine also the values of isolated renal clearance for each kidney separately. (author)

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Research Consortia CF Biomarker Consortium CFTR 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ...

  6. Tip Cells in Angiogenesis

    NARCIS (Netherlands)

    M.G. Dallinga (Marchien); S.E.M. Boas (Sonja); I. Klaassen (Ingeborg); R.M.H. Merks (Roeland); C.J.F. van Noorden; R.O. Schlingemann (Reinier)

    2015-01-01

    htmlabstractIn angiogenesis, the process in which blood vessel sprouts grow out from a pre-existing vascular network, the so-called endothelial tip cells play an essential role. Tip cells are the leading cells of the sprouts; they guide following endothelial cells and sense their environment for

  7. Tip model of cold fission

    International Nuclear Information System (INIS)

    Goennenwein, F.; Boersig, B.

    1991-01-01

    Cold fission is defined to be the limiting case of nuclear fission where virtually all of the available energy is converted into the total kinetic energy of the fragments. The fragments have, therefore, to be born in or at least close to their respective ground states. Starting from the viewpoint that cold fission corresponds to most compact scission configurations, energy constraints have been exploited to calculate minimum tip distances between the two nascent fragments in binary fission. Crucial input parameters to this tip model of cold fission are the ground-state deformations of fragment nuclei. It is shown that the minimum tip distances being compatible with energy conservation vary strongly with both the mass and charge fragmentation of the fission prone nucleus. The tip distances refer to nuclei with equivalent sharp surfaces. In keeping with the size of the surface width of leptodermous nuclei, only configurations where the tip distances are smaller than a few fm may be considered as valid scission configurations. From a comparison with experimental data on cold fission this critical tip distance appears to be 3.0 fm for the model parameters chosen. Whenever the model calculation yields tip distances being smaller than the critical value, a necessary condition for attaining cold fission is considered to be fulfilled. It is shown that this criterion allows to understand in fair agreement with experiment which mass fragmentations are susceptible to lead to cold fission and which fragment-charge divisions are the most favored in each isobaric mass chain. Being based merely on energy arguments, the model cannot aim at predicting fragment yields in cold fission. However, the tip model proposed appears well suited to delineate the phase space where cold fission phenomena may come into sight. (orig.)

  8. Perspectives on hypertension outcomes after single-stage clearance of a complete staghorn renal calculus

    Directory of Open Access Journals (Sweden)

    Ranjit Chaudhary

    2017-01-01

    Full Text Available A 55-year-old male presented, in June 2013, with left flank pain. Investigations revealed a complete staghorn stone. He had undergone two sittings of extracorporeal shock wave lithotripsy (ESWL in 2008 for left renal stone. One year subsequent to this, he was diagnosed with hypertension and diabetes. The management of complete staghorn stones in a single sitting is a difficult proposition. Percutaneous nephrolithotomy (PCNL is the gold standard to manage such stones. The patient was subjected to PCNL, and complete clearance was achieved in one sitting. On one-year follow-up, there was a significant reduction in blood pressure (BP and better glycemic control. Although there are several reports where hypertension has been reported after multiple sittings of ESWL, whether ESWL contributed to the genesis of hypertension and diabetes in this patient or it was simply incidental, cannot be stated with certainty. There was a significant reduction in the BP after complete stone removal, but there is uncertainty over the effect of total clearance of renal stones on hypertension, and we need to await the results of more controlled trials studying this phenomenon. A better glycemic control was perhaps achieved secondary to the eradication of recurrent urinary tract infections due to complete stone clearance.

  9. Inherited Disorders of Bilirubin Clearance

    Science.gov (United States)

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-01-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective 1) unconjugated bilirubin uptake and intrahepatic storage, 2) conjugation of glucuronic acid to bilirubin (e.g. Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), 3) bilirubin excretion into bile (Dubin-Johnson syndrome), or 4) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  10. Clearance of Sclerostin, Osteocalcin, Fibroblast Growth Factor 23, and Osteoprotegerin by Dialysis

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Mortensen, Ole H.; Axelsen, Mette

    2017-01-01

    Introduction: Fibroblast growth factor (FGF23), sclerostin, osteocalcin, and osteoprotegerin are important factors that control mineral bone metabolism. End-stage renal disease is associated with the pronounced dysregulation of mineral bone metabolism; however, the impact and clearance of mineral...

  11. Control of wing-tip vortex using winglets at low Reynolds number

    Science.gov (United States)

    Cho, Seunghyun; Choi, Haecheon

    2014-11-01

    Winglets are considered as one of the effective devices for reducing induced drag, and thus many studies have been conducted, but mainly at high Reynolds numbers (Re ~106 ~107) for commercial airplanes. However, small-size unmanned air vehicles (UAV), operating at low Reynolds numbers (Re PIV measurements are conducted at several cross-flow planes for a few different angles of attack (α) . At high angles of attack (7° ~13°) , the winglets with the cant angle of 70° increase the aerodynamic performance, whereas at low angles of attack (2° ~6°) , the wing-tip extension (cant angle of 0°) shows better performances. The velocity fields measured from PIV indicate that, with the winglet, the wing-tip vortex moves away from the wing surface at α =12° , and the downwash motion in the wake behind the trailing edge is decreased, reducing the magnitude of the induced drag. A concept of changing the cant angle during flight is also suggested at this talk. Supported by 2011-0028032.

  12. Green technology; only Forest Clearance is needed

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was land in Murmurwadi still under litigation made available? How was ...

  13. Nuclear regulation. NRC's security clearance program can be strengthened

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Kruslicky, Mary Ann; Bagnulo, John E.

    1988-12-01

    Because of the national security implications of its programs, the Nuclear Regulatory Commission (NRC) investigates the background of its employees and consultants as well as others to ensure that they are reliable and trustworthy. If the investigation indicates that an employee will not endanger national security, NRC grants a security clearance that allows access to classified information, material, and facilities. NRC also requires periodic checks for some clearance holders to ensure their continued clearance eligibility. The Chairman, Subcommittee on Environment, Energy, and Natural Resources, House Committee on Government Operations, asked GAO to review NRC's personnel security clearance program and assess the procedures that NRC uses to ensure that those who operate nuclear power plants do not pose a threat to the public. The Atomic Energy Act of 1954 requires NRC to conduct background investigations of its employees and consultants as well as others who have access to classified information, material, or facilities. To do this, NRC established a personnel security clearance program. Under NRC policies, a security clearance is granted after the Office of Personnel Management (OPM) or the Federal Bureau of Investigation checks the background of those applying for an NRC clearance. NRC also periodically reassesses the integrity of those holding the highest level clearance. NRC employees, consultants, contractors, and licensees as well as other federal employees hold approximately 10,600 NRC clearances. NRC does not grant clearances to commercial nuclear utility employees unless they require access to classified information or special nuclear material. However, the utilities have voluntarily established screening programs to ensure that their employees do not pose a threat to nuclear plants. NRC faces a dilemma when it hires new employees. Although its policy calls for new hires to be cleared before they start work, the security clearance process takes so long

  14. Early warning of climate tipping points

    Science.gov (United States)

    Lenton, Timothy M.

    2011-07-01

    A climate 'tipping point' occurs when a small change in forcing triggers a strongly nonlinear response in the internal dynamics of part of the climate system, qualitatively changing its future state. Human-induced climate change could push several large-scale 'tipping elements' past a tipping point. Candidates include irreversible melt of the Greenland ice sheet, dieback of the Amazon rainforest and shift of the West African monsoon. Recent assessments give an increased probability of future tipping events, and the corresponding impacts are estimated to be large, making them significant risks. Recent work shows that early warning of an approaching climate tipping point is possible in principle, and could have considerable value in reducing the risk that they pose.

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study Services Working With the TDN Tools and Resources ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center ...

  17. AFM tip-sample convolution effects for cylinder protrusions

    Science.gov (United States)

    Shen, Jian; Zhang, Dan; Zhang, Fei-Hu; Gan, Yang

    2017-11-01

    A thorough understanding about the AFM tip geometry dependent artifacts and tip-sample convolution effect is essential for reliable AFM topographic characterization and dimensional metrology. Using rigid sapphire cylinder protrusions (diameter: 2.25 μm, height: 575 nm) as the model system, a systematic and quantitative study about the imaging artifacts of four types of tips-two different pyramidal tips, one tetrahedral tip and one super sharp whisker tip-is carried out through comparing tip geometry dependent variations in AFM topography of cylinders and constructing the rigid tip-cylinder convolution models. We found that the imaging artifacts and the tip-sample convolution effect are critically related to the actual inclination of the working cantilever, the tip geometry, and the obstructive contacts between the working tip's planes/edges and the cylinder. Artifact-free images can only be obtained provided that all planes and edges of the working tip are steeper than the cylinder sidewalls. The findings reported here will contribute to reliable AFM characterization of surface features of micron or hundreds of nanometers in height that are frequently met in semiconductor, biology and materials fields.

  18. Improved flare tip design

    Energy Technology Data Exchange (ETDEWEB)

    Gogolek, P. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Energy Technology Centre

    2004-07-01

    This paper discusses the testing procedures and development of an improved flare tip design. Design objectives included performance equal to or better than utility flares at low wind speed; conversion efficiency; fuel slip; smoking; significant improvement at high wind speed; and no increase in trace emissions. A description of the testing facility of the flare tip was provided, with reference to the fact that the facility allowed for realistic near full scale gas flares in a single-pass flare test facility. Other details of the facility included: an adjustable ceiling; high capacity variable speed fan; sampling ports along working section in stack; windows along working section; and air cooled walls, floor, and ceiling. The fuels used in the flare tip included natural gas, propane, gasoline and inert gases. Details of wind speed, appurtenances and turbulence generating grids were presented, with reference to continuous gas emission measurements. A list of design constraints was provided. Flare performance included wind speed, turbulence and fuel composition. A chart of conversion inefficiencies with a correlation of wind speed and turbulence, fuel flow and pipe size was also presented. Several new tip designs were fabricated for testing, with screening tests for comparison to basic pipe and ranking designs. Significant improvements were found in one of the new designs, including results with 30 per cent propane in fuel. Emissions reduction from 10 to 35 per cent were noted. It was concluded that future work should focus on evaluating improved tip for stability at low wind speeds. Fuel slips are the primary source of emissions, and it was recommended that further research is necessary to improve existing flare tips. tabs, figs.

  19. Twelve tips for effective body language for medical educators.

    Science.gov (United States)

    Hale, Andrew J; Freed, Jason; Ricotta, Daniel; Farris, Grace; Smith, C Christopher

    2017-09-01

    A significant proportion of human communication is nonverbal. Although the fields of business and psychology have significant literature on effectively using body language in a variety of situations, there is limited literature on effective body language for medical educators. To provide 12 tips to highlight effective body language strategies and techniques for medical educators. The tips provided are based on our experiences and reflections as clinician-educators and the available literature. The 12 tips presented offer specific strategies to engage learners, balance learner participation, and bring energy and passion to teaching. Medical educators seeking to maximize their effectiveness would benefit from an understanding of how body language affects a learning environment and how body language techniques can be used to engage audiences, maintain attention, control challenging learners, and convey passion for a topic. Understanding and using body language effectively is an important instructional skill.

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study ...

  1. Autogenic drainage for airway clearance in cystic fibrosis.

    Science.gov (United States)

    McCormack, Pamela; Burnham, Paul; Southern, Kevin W

    2017-10-06

    Autogenic drainage is an airway clearance technique that was developed by Jean Chevaillier in 1967. The technique is characterised by breathing control using expiratory airflow to mobilise secretions from smaller to larger airways. Secretions are cleared independently by adjusting the depth and speed of respiration in a sequence of controlled breathing techniques during exhalation. The technique requires training, concentration and effort from the individual. It is important to systematically review the evidence demonstrating that autogenic drainage is an effective intervention for people with cystic fibrosis. To compare the clinical effectiveness of autogenic drainage in people with cystic fibrosis with other physiotherapy airway clearance techniques. We searched the Cochrane Cystic Fibrosis Trials Register, compiled from electronic database searches and handsearching of journals and conference abstract books. We also searched the reference lists of relevant articles and reviews, as well as two trials registers (31 August 2017).Dtae of most recent search of the Cochrane Cystic Fibrosis Trials Register: 25 September 2017. We identified randomised and quasi-randomised controlled studies comparing autogenic drainage to another airway clearance technique or no therapy in people with cystic fibrosis for at least two treatment sessions. Data extraction and assessments of risk of bias were independently performed by two authors. The authors assessed the quality of the evidence using the GRADE system. The authors contacted two investigators for further information pertinent to their published studies. Searches retrieved 35 references to 21 individual studies, of which seven (n = 208) were eligible for inclusion. One study was of parallel design with the remaining six being cross-over in design; participant numbers ranged from 17 to 75. The total study duration varied between four days and two years. The age of participants ranged between seven and 63 years with a wide

  2. Green Compact Temperature Evolution during Current-Activated Tip-Based Sintering (CATS of Nickel

    Directory of Open Access Journals (Sweden)

    Khaled Morsi

    2013-04-01

    Full Text Available Current-activated tip-based sintering (CATS is a novel process where spark plasma sintering conditions are applied through an electrically conducting tip on a locally controlled area on a green powder compact/bed. The localization of electric current in CATS allows for unique temporal and spatial current and temperature distributions within the tip and powder compact. In this paper, special experimental setups were used to monitor the temperature profiles in the tip and at multiple locations on the surface of nickel powder compacts. A variation in the initial green density was found to have a significant effect on the maximum temperature in the tip as well as the temperature distribution across the powder compact. In general, the lowest green density specimens displayed the best conditions for localized densification. The concept of effective current density is introduced and results are discussed in relation to the densification parameter.

  3. Intraarticular volume and clearance in human synovial effusions

    International Nuclear Information System (INIS)

    Wallis, W.J.; Simkin, P.A.; Nelp, W.B.; Foster, D.M.

    1985-01-01

    Intraarticular volumes were measured by radiolabeled albumin (RISA) distribution in chronic knee effusions from 11 rheumatoid arthritis patients and 9 osteoarthritis patients. Volumes of synovial fluid obtained at joint aspiration were substantially less than those found by RISA dilution. Up to 24 hours was needed for full distribution of RISA throughout the intraarticular compartment. Measured 123I and RISA radioactivity over the knee described monoexponential rate constants, lambda (minute-1). The clearance of 123I and RISA from synovial effusions was derived by the formulation volume (ml) X lambda (minute-1) = clearance (ml/minute). RISA clearance in rheumatoid effusions was significantly greater than that found in osteoarthritis effusions. Intraarticular volume and isotope clearance were easily quantified and provide measures for further evaluating the microvascular physiology of synovial effusions

  4. Reconstruction of the Tip-Surface Interaction Potential by Analysis of the Brownian Motion of an Atomic Force Microscope Tip

    NARCIS (Netherlands)

    Willemsen, O.H.; Kuipers, L.; van der Werf, Kees; de Grooth, B.G.; Greve, Jan

    2000-01-01

    The thermal movement of an atomic force microscope (AFM) tip is used to reconstruct the tip-surface interaction potential. If a tip is brought into the vicinity of a surface, its movement is governed by the sum of the harmonic cantilever potential and the tip-surface interaction potential. By

  5. Determination of hepatic fractional clearance of radioactive gold colloids for a measure of effective hepatic blood flow

    International Nuclear Information System (INIS)

    Fujii, Masahiro

    1979-01-01

    For a measure of effective blood flow, a hepatic fractional clearance of 198 Au-colloids was determined, which was obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic uptake was determined with a gamma camera. The counts over the liver was corrected for body weight and height. The method was considered sufficiently simple for routine use. 198 Au-colloids were obtained from Dainabot Lab. and CIS. The former gave 64% higher values of disappearance rate than the latter, without any change in the organ distribution. A quality control tests were applied over a six-year period to the disappearance rates. Reproducibility within 95 to confidence limits was found for both groups. In 28 normal control subjects, hepatic fractional clearance of the colloids from Dainabot Lab. was 18.5 +- 3.4%/min. In patients with progressed hepatic disease, both hepatic fractional clearance and final hepatic uptake were decreased, showing that the determination of hepatic uptake is necessary in measuring effective hepatic blood flow by the colloidal clearance method. The influence of splenic uptake is discussed in relation to hepatic blood flow measurement. (author)

  6. Thermal study of bare tips with various system parameters and incision sizes.

    Science.gov (United States)

    Osher, Robert H; Injev, Valentine P

    2006-05-01

    To identify major and minor surgeon-controlled parameters that affect incision temperature when performing microincision lens removal using the Alcon Infiniti Vision System. In vitro research and development laboratory, Alcon Research, Irvine, California, USA. Phacoemulsification was performed in eye-bank cadaver eyes and the following parameters evaluated: incision, duty cycle, ultrasound (US) power, aspiration flow rate (AFR), vacuum, pulse, bottle height and balanced salt solution temperature, and tip design/size. Each parameter was varied while the others remained constant. The resulting temperature of the incision and US tip was measured using a thermal camera. Major contributors to elevated incision temperature included incision size, US power, duty cycle, AFR, vacuum setting, tip design, and presence of an ophthalmic viscosurgical device (OVD). Minor contributors included pulse frequency, bottle height, and temperature of the infusate. Microincision lens removal can be performed at safe temperatures with the knowledgeable selection of surgeon-controlled parameters.

  7. Effects of Intraluminal Irradiation with Holmium-166 for TIPS Stenosis: Experimental Study in a Swine Model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Seon; Oh, Joo Hyeong; Kim, Deog Yoon; Park, Yong Koo; Kim, Soo Joong [Kyung Hee University Medical Center, Seoul (Korea, Republic of); Park, Sang Joon [Kang Dong Sacred Heart Hospital, Hallym University, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to evaluate the effectiveness of intraluminal irradiation with Holmium-166 ({sup 166}Ho) for reducing the pseudointimal hyperplasia (PIH) in the transjugular intrahepatic portosystemic shunt (TIPS) tract in a swine model. TIPS was performed in 12 domestic pigs, after the creation of portal hypertension by intraportal injection of a mixture of N-butyl-2- cyanoacrylate (NBCA) and lipiodol. Five pigs first underwent intraluminal irradiation (30 Gy) in the parenchymal tract with using a {sup 166}Ho solution-filled balloon catheter, and this was followed by the placement of a nitinol stent in the TIPS tract. For the seven control pigs, the balloon was filled with saline and contrast media mixture. Two weeks later, follow-up portography and histological analysis were performed. TIPS was successfully performed in all twelve pigs with achieving artificially induced portal hypertension. Portography performed two weeks after TIPS showed the patent tracts in the TIPS tracts that were irradiated with {sup 166}Ho (5/5, 100%), whereas either completely (5/6, 83.3%) or partially (1/6, 16.7%) occluded TIPS were seen in the seven pigs of the nonirradiated control group, except in one pig that experienced periprocedural death due to bleeding. Histological analysis showed a statistically significant difference for the maximal PIH (irradiated: 32.8%, nonirradiated: 76.0%, p < 0.001) between the two groups. Intraluminal irradiation with 30 Gy of {sup 166}Ho for TIPS significantly improved the TIPS patency in a swine model of portal hypertension during a 2- week period of follow-up.

  8. Controlling molecular condensation/diffusion of copper phthalocyanine by local electric field induced with scanning tunneling microscope tip

    Science.gov (United States)

    Nagaoka, Katsumi; Yaginuma, Shin; Nakayama, Tomonobu

    2018-02-01

    We have discovered the condensation/diffusion phenomena of copper phthalocyanine (CuPc) molecules controlled with a pulsed electric field induced by the scanning tunneling microscope tip. This behavior is not explained by the conventional induced dipole model. In order to understand the mechanism, we have measured the electronic structure of the molecule by tunneling spectroscopy and also performed theoretical calculations on molecular orbitals. These data clearly indicate that the molecule is positively charged owing to charge transfer to the substrate, and that hydrogen bonding exists between CuPc molecules, which makes the molecular island stable.

  9. Bacterial Contamination in Tips of Electrocautery Devices During Total Hip Arthroplasty.

    Science.gov (United States)

    Shahi, Alisina; Chen, Antonia F; McKenna, Paul B; Roberts, Amity L; Manrique, Jorge; Belden, Katherine A; Austin, Matthew S

    2015-08-01

    Surgical equipment can become contaminated during surgery. It is unknown if electrocautery tips can become contaminated in clean orthopedic procedures despite the produced heat. Therefore, we conducted a prospective study to address this concern. The tips from 25 primary and 25 aseptic revision THAs were collected and an additional 5 sterile tips served as negative controls. Aerobic and anaerobic cultures were incubated for a minimum of 3 days. There were 3 positive cultures (6%); one in primary THA (4%) with Lactobacillus and Enterococcus faecalis; two among revisions (8%), one with E. faecalis and another one with alpha hemolytic streptococci and coagulase negative Staphylococcus. The mean exposure time of the contaminated tips was 132.3 minutes. Patients were followed for 90 days postoperatively and none of them developed surgical site infection. This is the first study to demonstrate that electrosurgical devices can become contaminated during THA in laminar flow equipped operating rooms. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The tear turnover and tear clearance tests - a review.

    Science.gov (United States)

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  12. Enzyme-inducing anticonvulsants increase plasma clearance of dexmedetomidine: a pharmacokinetic and pharmacodynamic study.

    Science.gov (United States)

    Flexman, Alana M; Wong, Harvey; Riggs, K Wayne; Shih, Tina; Garcia, Paul A; Vacas, Susana; Talke, Pekka O

    2014-05-01

    Dexmedetomidine is useful during mapping of epileptic foci as it facilitates electrocorticography unlike most other anesthetic agents. Patients with seizure disorders taking enzyme-inducing anticonvulsants appear to be resistant to its sedative effects. The objective of the study was to compare the pharmacokinetic and pharmacodynamic profile of dexmedetomidine in healthy volunteers with volunteers with seizure disorders receiving enzyme-inducing anticonvulsant medications. Dexmedetomidine was administered using a step-wise, computer-controlled infusion to healthy volunteers (n = 8) and volunteers with seizure disorders (n = 8) taking phenytoin or carbamazapine. Sedation and dexmedetomidine plasma levels were assessed at baseline, during the infusion steps, and after discontinuation of the infusion. Sedation was assessed by using the Observer's Assessment of Alertness/Sedation Scale, Ramsay Sedation Scale, and Visual Analog Scale and processed electroencephalography (entropy) monitoring. Pharmacokinetic analysis was performed on both groups, and differences between groups were determined using the standard two-stage approach. A two-compartment model was fit to dexmedetomidine concentration-time data. Dexmedetomidine plasma clearance was 43% higher in the seizure group compared with the control group (42.7 vs. 29.9 l/h; P = 0.007). In contrast, distributional clearance and the volume of distribution of the central and peripheral compartments were similar between the groups. No difference in sedation was detected between the two groups during a controlled range of target plasma concentrations. This study demonstrates that subjects with seizure disorders taking enzyme-inducing anticonvulsant medications have an increased plasma clearance of dexmedetomidine as compared with healthy control subjects.

  13. Effects of dipyridamole-induced vasodilation on myocardial uptake and clearance kinetics of thallium-201

    International Nuclear Information System (INIS)

    Beller, G.A.; Holzgrefe, H.H.; Watson, D.D.

    1983-01-01

    Myocardial thallium-201 (201Tl) uptake and clearance after intravenous administration of dipyridamole (150 micrograms/kg) were determined in 12 open-chest anesthetized dogs with a partial coronary artery stenosis. 201Tl (1.5 mCi) was injected intravenously and myocardial biopsy specimens were obtained 10 min, 60 min, and 2 hr after injection. Serial changes in 201Tl activity in the normal zone and in the zone of partial stenosis were correlated with microsphere-determined regional blood flow and distal coronary pressure. Another nine dogs with equivalent stenosis not given dipyridamole before 201Tl served as controls. Data indicate that dipyridamole-induced vasodilation in the presence of a partial stenosis results in diminished uptake and delayed clearance compared with increased uptake and more rapid clearance in normally perfused myocardium producing an initial 201Tl defect with delayed redistribution

  14. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    Science.gov (United States)

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  15. Lung clearance of 99mTc-DTPA aerosols in chronic obstructive pulmonary disease and interstitial pneumopathy diffuse

    International Nuclear Information System (INIS)

    Maliska, Carmelindo; Mello, Rossana Corbo de; Fonseca, Lea M.B.; Maliska, Celsa M.; Wolosker, Sara; Albernaz, Marta S.; Marinho, J.C.A.; Lima, Jose E.T.; Jansen, Jose M.

    1996-01-01

    An increasement in pulmonary epithelial permeability occurs when the alveolar-capillary units are disrupted. This permeability increasement can be measured by the 99m Tc-DTPA aerosol washout from lungs. Twenty three patients (10 healthy normal controls, 6 with COPD, 5 with diffuse infiltrative lung disease (DILD) and 2 asyntomatic patients that underwent radioiodine therapy dose) in order to verify the lung clearance rate of 99m Tc-DTPA in our population. The mean and standard deviation of pulmonary clearance rate in the normal group was 0,722±0,098%min -1 . The COPD patients rate resembled to the normal group rate. Four in five DILD patients had increased pulmonary clearance rate. The 2 patients that underwent radioiodine therapeutic showed normal clearance values of 99m Tc-DTPA from lungs. Our preliminary observations suggest that 99 'm Tc-DTPA clearance can be used as valuable tool in assessing early stages of pulmonary disorders in systemic diseases that may affect the lung. We also suggest that COPD does not seem to raise the pulmonary epithelial permeability. (author)

  16. Tips for Living with Scleroderma

    Science.gov (United States)

    ... Patients Tips for Living Tips for Living with Scleroderma Ways to help manage your symptoms The Scleroderma ... help find improved therapies and a cure for scleroderma! Your gift today will be matched to have ...

  17. Attosecond-controlled photoemission from metal nanowire tips in the few-electron regime

    KAUST Repository

    Ahn, B.; Schö tz, J.; Kang, M.; Okell, W. A.; Mitra, S.; Fö rg, B.; Zherebtsov, S.; Sü ß mann, F.; Burger, C.; Kü bel, M.; Liu, C.; Wirth, A.; Di Fabrizio, Enzo M.; Yanagisawa, H.; Kim, D.; Kim, B.; Kling, M. F.

    2017-01-01

    sources for microscopy. Here, we report the generation of high energy photoelectrons (up to 160 eV) in photoemission from single-crystalline nanowire tips in few-cycle, 750-nm laser fields at peak intensities of (2-7.3) × 1012 W/cm2. Recording the carrier

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... or bypass, without the risks that accompany open surgery. TIPS is a minimally invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of an effect ...

  19. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    Science.gov (United States)

    2014-04-24

    collision; VAP , ventilator-associated pneumonia. TABLE 2. PK Parameter Estimates for Free Piperacillin and Tazobactam in Patients Stratified by ARC Score...SOFA score are typically generated during routine care of the most severely ill patients . Positive screening test results (high ARC scores) can be...Modified Augmented Renal Clearance score predicts rapid piperacillin and tazobactam clearance in critically ill surgery and trauma patients Kevin S

  20. Blunt-tip coaxial introducer: a revisited tool for difficult CT-guided biopsy in the chest and abdomen.

    Science.gov (United States)

    de Bazelaire, Cedric; Farges, Cecile; Mathieu, Olivier; Zagdanski, Anne-Marie; Bourrier, Pierre; Frija, Jacques; de Kerviler, Eric

    2009-08-01

    We describe a coaxial introducer provided with an additional blunt-tip stylet that allows safe access to difficult-to-reach lymph nodes in the chest, abdomen, and pelvis under CT control. Once the thoracic, abdominal, or pelvic wall is crossed by the introducer fitted with the sharp-tip stylet, the blunt-tip stylet replaces the sharp stylet for further progression in the fat toward the target. The soft-tip stylet carries a smaller risk of inadvertent perforation displacing vital structures.

  1. Structure and dynamics of TIP3P, TIP4P, and TIP5P water near smooth and atomistic walls of different hydroaffinity

    International Nuclear Information System (INIS)

    Harrach, Michael F.; Drossel, Barbara

    2014-01-01

    We perform molecular dynamics simulations to observe the structure and dynamics of water using different water models (TIP3P, TIP4P, TIP5P) at ambient conditions, constrained by planar walls, which are either modeled by smooth potentials or regular atomic lattices, imitating the honeycomb-structure of graphene. We implement walls of different hydroaffinity, different lattice constant, and different types of interaction with the water molecules. We find that in the hydrophobic regime the smooth wall generally represents a good abstraction of the atomically rough walls, while in the hydrophilic regime there are noticeable differences in structure and dynamics between all stages of wall roughness. For a small lattice constant however the smooth and the atomically rough wall still share a number of structural and dynamical similarities. Out of the three water models, TIP5P water shows the largest degree of tetrahedral ordering and is often the one that is least perturbed by the presence of the wall

  2. RANS computations of tip vortex cavitation

    Science.gov (United States)

    Decaix, Jean; Balarac, Guillaume; Dreyer, Matthieu; Farhat, Mohamed; Münch, Cécile

    2015-12-01

    The present study is related to the development of the tip vortex cavitation in Kaplan turbines. The investigation is carried out on a simplified test case consisting of a NACA0009 blade with a gap between the blade tip and the side wall. Computations with and without cavitation are performed using a R ANS modelling and a transport equation for the liquid volume fraction. Compared with experimental data, the R ANS computations turn out to be able to capture accurately the development of the tip vortex. The simulations have also highlighted the influence of cavitation on the tip vortex trajectory.

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... filtered out by the liver. The TIPS may cause too much of these substances to bypass the ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... then placed in this tunnel to keep the pathway open. Patients who typically need a TIPS have ... and stomach. A TIPS procedure involves creating a pathway through the liver that connects the portal vein ( ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and/or hydrothorax (in the chest). Budd-Chiari syndrome , a blockage in one or more veins that ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the esophagus and stomach. A TIPS procedure involves creating a pathway through the liver that connects the ... diseases. This can result in significant challenges in creating the TIPS. top of page Additional Information and ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS. top of page What are some common uses of the procedure? A TIPS is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... recovery time than surgery. Your TIPS should have less of an effect than open surgical bypass on ...

  9. Effect of the presence of dental plaque on oral sugar clearance and salivary pH: an in vivo study.

    Science.gov (United States)

    Pradhan, Debapriya; Jain, Deepak; Gulati, Amit; Kolhe, Swapnil J; Baad, Rajendra; Rao, B Sunil

    2012-11-01

    Fermentable carbohydrates and microorganisms in the plaque play a significant role in the pathogenesis of dental caries. Oral clearance of sugars and salivary pH is affected by the presence of plaque. This study was conducted to study the effect of the presence of plaque on the salivary clearance of sucrose and on salivary pH. The study design was of a randomized controlled parallel group clinical trial and included two groups: The control group and plaque group, as follows: Control group--subjects without plaque and plaque group--subjects with plaque. Salivary sucrose determination was done by using the anthrone technique. A digital pH meter estimated the salivary pH. The Student's t test and Mann-Whitney test was employed to compare the intergroup differences. Pearson's correlation coefficient was used for analysis. The salivary sucrose clearance time was increased by presence of plaque. The presence of plaque led to increased salivary sucrose concentrations and increased the salivary sucrose clearance time. The dental caries is the dynamic relationship among the dental plaque microbiota, dietary carbohydrates, saliva and cariogenic potential of the dental plaque. Caries occur preferentially in the dentition sites characterized by high exposure to carbohydrate and diminished salivary effect.

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in CF Clinical Care Guidelines Cystic Fibrosis-Related Diabetes Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care Guidelines Chronic Medications to Maintain Lung ...

  11. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  12. 2015 Annual Report on Security Clearance Determinations

    Science.gov (United States)

    2016-06-28

    only have delegated investigative authority over their civilian employee population and therefore, can only report the overall timeliness for that...completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...Clearance Determinations to Congress. The IAA directs this report to include the number of United States Government (USG) employees who held a

  13. Dynamic modelling and experimental study of cantilever beam with clearance

    International Nuclear Information System (INIS)

    Li, B; Jin, W; Han, L; He, Z

    2012-01-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  14. Dynamic modelling and experimental study of cantilever beam with clearance

    Science.gov (United States)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  15. A probabilistic assessment code system for derivation of clearance levels of radioactive materials. PASCLR user's manual

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tomoyuki [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst; Takeda, Seiji; Kimura, Hideo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-01-01

    It is indicated that some types of radioactive material generating from the development and utilization of nuclear energy do not need to be subject regulatory control because they can only give rise to trivial radiation hazards. The process to remove such materials from regulatory control is called as 'clearance'. The corresponding levels of the concentration of radionuclides are called as 'clearance levels'. In the Nuclear Safety Commission's discussion, the deterministic approach was applied to derive the clearance levels, which are the concentrations of radionuclides in a cleared material equivalent to an individual dose criterion. Basically, realistic parameter values were selected for it. If the realistic values could not be defined, reasonably conservative values were selected. Additionally, the stochastic approaches were performed to validate the results which were obtained by the deterministic calculations. We have developed a computer code system PASCLR (Probabilistic Assessment code System for derivation of Clearance Levels of Radioactive materials) by using the Monte Carlo technique for carrying out the stochastic calculations. This report describes the structure and user information for execution of PASCLR code. (author)

  16. Light depolarization induced by metallic tips in apertureless near-field optical microscopy and tip-enhanced Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gucciardi, P G [CNR-Istituto per i Processi Chimico-Fisici, sezione Messina, Salita Sperone, Contrada Papardo, I-98158 Faro Superiore, Messina (Italy); Lopes, M; Deturche, R; Julien, C; Barchiesi, D; Chapelle, M Lamy de la [Institut Charles Delaunay-CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de Technologie de Troyes, 12 rue Marie Curie, BP2060, 10010 Troyes (France)

    2008-05-28

    We have investigated the depolarization effects of light scattered by sharp tips used for apertureless near-field optical microscopy. Dielectric and metal coated tips have been investigated and depolarization factors between 5 and 30% have been measured, changing as a function of the incident light polarization and of the tip shape. The experimental results are in good agreement with theoretical calculations performed by the finite element method, giving a near-field depolarization factor close to 10%. The effect of depolarization has been investigated in polarized tip-enhanced Raman spectroscopy (TERS) experiments; the depolarization gives rise to forbidden Raman modes in Si crystals.

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... many challenges, including medical, social, and financial. By learning more about how you can manage your disease every day, you can ultimately help find a ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic ...

  18. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  19. Chaos vibration of pinion and rack steering trapezoidal mechanism containing two clearances

    Science.gov (United States)

    Wei, Daogao; Wang, Yu; Jiang, Tong; Zheng, Sifa; Zhao, Wenjing; Pan, Zhijie

    2017-08-01

    The multi-clearances of breaking type steering trapezoidal mechanism joints influences vehicle steering stability. Hence, to ascertain the influence of clearance value on steering stability, this paper takes the steering mechanism of a certain vehicle type as a prototype that can be simplified into a planar six-bar linkage, then establishes the system dynamic differential equations after considering the two clearances of tie rods and the steering knuckle arms. The influence of the clearance parameters on the movement stability of the steering mechanism is studied using a numerical computation method. Results show that when the two clearances are equal, the planar movement of the tie rods changes from period-doubling to chaos as the clearances increase. When the two clearances are 0.25 mm and 1.5 mm respectively, the planar movements of the two side tie rods come into chaos, causing the steering stability to deteriorate. Moreover, with the increase of clearances, turning moment fluctuates more intensively and the peak value increases.

  20. TGF-beta1 immunohistochemistry and promoter methylation in chronic renal failure rats treated with Uremic Clearance Granules.

    Directory of Open Access Journals (Sweden)

    Cheng-Bin Chen

    2010-08-01

    Full Text Available The aim of the study was the explain the mechanism related to therapeutic effects of Uremic Clearance Granules (Niaoduqing Keli in Chinese on adenine-induced Chronic Renal Failure in rats. Thirty 8-week-old male Wistar rats were selected and randomly divided in to 3 groups: Normal Control Group (NCGconsisted of 10 rats, Chronic Renal Failure Pathological Control Group (PCG 10 rats, and Uremic Clearance Granules Treatment Group (UCG 10 rats. Each rat in PCG and UCG was fed with adenine-enriched diets, containing 10 g adenine per kg food for 6 weeks. After fed with adenine, each rat in UCG was administered orally with 2 ml solution of Uremic Clearance Granules for 6 weeks. The concentration of Uremic Clearance Granules solution was 0.42 g/ml which was 10 times of human. On days 42 and 84, the serum levels of creatinine, Blood Urea Nitrogen and homocysteine were determined. The methylation of TGFbeta1 promoter was tested by methylation-specific PCR. TGF-beta1 mRNA and protein expression in rat renal cortex were analyzed by real-time RT-PCR and Immunohistochemistry. (1 Experimented on model of Chronic Renal Failure in rats, the preparation was proved to be able to reduce serum creatinine, Blood Urea Nitrogen, and homocysteine (p<0.05, improve renal function. (2 The expression of TGF-beta1 in mRNA and protein level were down-regulated. (3 TGF-beta1 promoter was demethylated at some loci in PCG, and was recovered in UCG. After treatment with Uremic Clearance Granules, the Chronic Renal Failure Wistar rat's kidney function was recovered. The recovery may be result of the remethylation of TGF-beta1 promoter and then lead to TGF-beta1 be transcripted and translated normally. The experimental study explain the molecular mechanism by which Uremic Clearance Granules treat Chronic Renal Failure.

  1. Dynamic clearance measure to evaluate locomotor and perceptuo-motor strategies used for obstacle circumvention in a virtual environment.

    Science.gov (United States)

    Darekar, Anuja; Lamontagne, Anouk; Fung, Joyce

    2015-04-01

    Circumvention around an obstacle entails a dynamic interaction with the obstacle to maintain a safe clearance. We used a novel mathematical interpolation method based on the modified Shepard's method of Inverse Distance Weighting to compute dynamic clearance that reflected this interaction as well as minimal clearance. This proof-of-principle study included seven young healthy, four post-stroke and four healthy age-matched individuals. A virtual environment designed to assess obstacle circumvention was used to administer a locomotor (walking) and a perceptuo-motor (navigation with a joystick) task. In both tasks, participants were asked to navigate towards a target while avoiding collision with a moving obstacle that approached from either head-on, or 30° left or right. Among young individuals, dynamic clearance did not differ significantly between obstacle approach directions in both tasks. Post-stroke individuals maintained larger and smaller dynamic clearance during the locomotor and the perceptuo-motor task respectively as compared to age-matched controls. Dynamic clearance was larger than minimal distance from the obstacle irrespective of the group, task and obstacle approach direction. Also, in contrast to minimal distance, dynamic clearance can respond differently to different avoidance behaviors. Such a measure can be beneficial in contrasting obstacle avoidance behaviors in different populations with mobility problems. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Superconducting phase transition in STM tips

    Energy Technology Data Exchange (ETDEWEB)

    Eltschka, Matthias; Jaeck, Berthold; Assig, Maximilian; Etzkorn, Markus; Ast, Christian R. [Max Planck Institute for Solid State Research, Stuttgart (Germany); Kern, Klaus [Max Planck Institute for Solid State Research, Stuttgart (Germany); Ecole Polytechnique Federale de Lausanne (Switzerland)

    2015-07-01

    The superconducting properties of systems with dimensions comparable to the London penetration depth considerably differ from macroscopic systems. We have studied the superconducting phase transition of vanadium STM tips in external magnetic fields. Employing Maki's theory we extract the superconducting parameters such as the gap or the Zeeman splitting from differential conductance spectra. While the Zeeman splitting follows the theoretical description of a system with s=1/2 and g=2, the superconducting gaps as well as the critical fields depend on the specific tip. For a better understanding of the experimental results, we solve a one dimensional Usadel equation modeling the superconducting tip as a cone with the opening angle α in an external magnetic field. We find that only a small region at the apex of the tip is superconducting in high magnetic fields and that the order of the phase transition is directly determined by α. Further, the spectral broadening increases with α indicating an intrinsic broadening mechanism due to the conical shape of the tip. Comparing these calculations to our experimental results reveals the order of the superconducting phase transition of the STM tips.

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... decisions about your health care. CF Genetics: The Basics CF Mutations Video Series Find Out More About ... of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing and ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway ... on their own. Share Facebook Twitter Email More options Print Share Facebook Twitter Email Print Permalink All ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in part to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of ... a cure for CF and supports a broad range of research initiatives to tackle the disease from ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care ... attack bacteria. Choose What's Best for You Your respiratory therapist or another member of your CF care ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  14. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  15. Measurement with nasal scintigraphy of nasal mucociliary clearance in normal man

    International Nuclear Information System (INIS)

    Murai, Sumiko

    1989-01-01

    Nasal mucociliary function was evaluated by nasal scintigraphy in normal subjects. A microdrop of HSA or saline labelled with 99m Tc was dripped into the middle part of each middle meatus in the nasal cavity and its clearance was observed by scinticamera. The accumulated concentration of RI was determined every 30 seconds for 10 minutes. The changes of accumulated concentration were studied, and a curve of decreasing RI-counts was obtained, with the 'clearance rate' defined as 100% for the count at the initial 30 seconds and 'half time' as the time when radioactivity was reduced to one half the initial count. Nasal resistance was measured by rhinomanometry with the oscillation method. In nonsmokers, 10μl of saline was cleared (78.0±10.4%) significantly faster than 10μl of HSA (59.9±24.6%), and there was no significant difference in the clearance between 10μl and 5μl of HSA (55.9±27.7%). In smakers, the mucociliary clearance of 10μl of HSA and saline was significantly lower than in nonsmokers. The clearance of 10μl of HSA reflects a pathological state much better than that of 5μl. In nonsmokers, there is a significant negative correlation between nasal resistance and clearance rate, suggesting that the more patent the nose, the faster the mucociliary clearance. When both nostrils were closed, the clearance rate was significantly depressed. When one nostril was closed, there was no significant effect on clearance. Nasal resistance was decreased by exercise with a bicycle ergometer. Nasal mucociliary clearance was slightly decreased after exercise but not significantly so. (J.P.N.)

  16. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Science.gov (United States)

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with... accidents that it says were avoidable and that resulted in damage to or destruction of waterway...

  17. The role of clearance in Germany - release of materials, buildings and sites

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    Clearance in Germany is far advanced. A complex regulatory framework exists in the Radiation Protection Ordinance (RPO/Strahlenschutzverordnung, StrlSchV) since 2001 which has replaced previous recommendations on clearance issued by the German Radiation Protection Commission (Strahlenschutzkommission, SSK). A number of options exist both for unconditional clearance (e.g. of all kinds of materials with no restrictions on the destination or future use) and for clearance for a specific purpose (e.g. recycling of metal scrap). For each clearance option there is a set of nuclide specific clearance levels which have been derived on the basis of the 10 Sv/a individual dose criterion using complex radiological models which are tailored to the respective material cycles (metal scrap, buildings, building rubble, waste for disposal, sites). The clearance levels have been thoroughly reviewed by the SSK. An extensive comparison to sets of clearance levels used in other countries or issued as guidance by international bodies revealed that the correspondence between values is between good and acceptable taking into account country-specific approaches and special assumptions which would not necessarily pertain to German situations. Clearance is a major factor in the material management, especially of nuclear installations undergoing decommissioning. The variety of clearance options leaves the operator of a nuclear installation sufficient flexibility for optimisation of the material management. Clearance is of particular importance in a country like Germany where the estimated costs for a future repository are very high and the interim storage facilities for radioactive material are limited and costly. While the licensee is responsible for his material management, the issuance of a clearance permit is done by the regulatory body upon application. The regulators may choose to use the clearance levels and regulations as stipulated by the RPO, or to impose site-specific regulations on

  18. Plasmonic Colloidal Nanoantennas for Tip-Enhanced Raman Spectrocopy

    Science.gov (United States)

    Dill, Tyler J.

    Plasmonic nanoantennas that a support localized surface plasmon resonance (LSPR) are capable of confining visible light to subwavelength dimensions due to strong electromagnetic field enhancement at the probe tip. Nanoantenna enable optical methods such as tip-enhanced Raman spectroscopy (TERS), a technique that uses scanning probe microscopy tips to provide chemical information with nanoscale spatial resolution and single-molecule sensitivities. The LSPR supported by the probe tip is extremely sensitive to the nanoscale morphology of the nanoantenna. Control of nanoscale morphology is notoriously difficult to achieve, resulting in TERS probes with poor reproducibility. In my thesis, I demonstrate high-performance, predictable, and broadband nanospectroscopy probes that are fabricated by self-assembly. Shaped metal nanoparticles are organized into dense layers and deposited onto scanning probe tips. When coupled to a metal substrate, these probes support a strong optical resonance in the gap between the substrate and the probe, producing dramatic field enhancements. I show through experiment and electromagnetic modeling that close-packed but electrically isolated nanoparticles are electromagnetically coupled. Hybridized LSPRs supported by self-assembled nanoparticles with a broadband optical response, giving colloidal nanoantenna a high tolerance for geometric variation resulting from fabrication. I find that coupled nanoparticles act as a waveguide, transferring energy from many neighboring nanoparticles towards the active TERS apex. I also use surface-enhanced Raman spectroscopy (SERS) to characterize the effects of nanoparticle polydispersity and gap height on the Raman enhancement. These colloidal probes have consistently achieved dramatic Raman enhancements in the range of 108-109 with sub-50 nm spatial resolution. Furthermore, in contrast to other nanospectroscopy probes, these colloidal probes can be fabricated in a scalable fashion with a batch

  19. Tips for Good Electronic Presentations.

    Science.gov (United States)

    Strasser, Dennis

    1996-01-01

    Describes library uses of presentation graphics software and offers tips for creating electronic presentations. Tips include: audience retention; visual aid options; software package options; presentation planning; presentation showing; and use of text, colors, and graphics. Sidebars note common presentation errors and popular presentation…

  20. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, A

    1984-01-01

    the clearance values based on arterial and venous sampling averaged 1.4 and 2.5 l/min, respectively (p less than 0.02). The difference in clearance values was due to peripheral uptake of NA averaging 45%. The plasma appearance rate on NA averaged 2.4 nmol/min before surgery and it increased to 9.5 nmol...... we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Make a Charitable Gift Our Corporate Supporters Workplace Engagement DONATE YOUR PROPERTY eCards for a Cure About ... airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... people with cystic fibrosis so that they make smart decisions about CF-related research, treatment, and access ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... CFTR Modulator Therapies Mucus Thinners Nebulizer Care at Home Vascular Access Devices PICCs and Ports Partnerships for ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  5. Effect of decreased blood flow and ischemia on myocardial thallium clearance

    International Nuclear Information System (INIS)

    Okada, R.D.; Pohost, G.M.

    1984-01-01

    To determine the effect of reduced coronary blood flow on myocardial thallium-201 clearance over a range of flows, miniature radiation detectors were inserted into the left ventricular apex and positioned against the anterior and posterior endocardial walls in 21 dogs. Thallium was administered intravenously and myocardial tracer activity was monitored continuously for 1 hour in both walls. A balloon occluder was then partially inflated around the left anterior descending coronary artery in 19 dogs, producing a range of anterior wall blood flow reductions as assessed by the microsphere technique. Thallium activity was monitored continuously for 3 hours in both walls. Two dogs served as control animals and had no coronary artery occlusion at 1 hour. At the end of the 4 hour experiment, the dogs were sacrificed and the hearts counted in a well counter. The 19 dogs with coronary artery stenosis were divided into three groups (mild, moderate and severe flow reduction groups) on the basis of their poststenosis anterior/posterior wall regional myocardial blood flow ratios. The two control dogs had similar thallium clearances in the anterior and posterior left ventricular walls during the 3 hour period, as assessed by the radiation detectors, and by a final anterior/posterior wall thallium ratio near unity. All three groups of dogs with coronary stenosis had comparable fractional thallium clearances from the anterior and posterior walls before and after the balloon occluder inflation. The final anterior/posterior left ventricular wall thallium ratios were not significantly different than unity for all three groups of dogs

  6. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  7. Depressed reticuloendothelial clearance of platelets in rats after trauma.

    Science.gov (United States)

    Kaplan, J E; Moon, D G; Minnear, F L; Saba, T M

    1984-02-01

    Platelet microembolization may contribute to microcirculatory and organ damage following trauma and shock. It is hypothesized that posttraumatic reticuloendothelial depression predisposes to such microembolization by failure to clear altered platelets from the circulation. The present study evaluated the short-term (1 h) clearance and organ localization of radiolabeled homologous damaged platelets in normal rats and in rats following sublethal Noble-Collip drum trauma. Platelets were collected in citrated platelet-rich plasma from normal rats and labeled with 51Cr in citrated saline. Platelets were altered by repeated centrifugation in protein-free medium. These platelets differed functionally and morphologically from normal platelets. Disappearance of iv injected damaged platelets conformed to a two-compartment exponential clearance. Velocity of clearance in the rapid compartment correlated with hepatic platelet localization, whereas velocity of clearance in the second compartment correlated with splenic platelet localization. Clearance rate of the rapid compartment was depressed at 1 h after trauma and elevated at 24 h. These changes were associated with a decrease in hepatic platelet localization at 1 h and an increase above normal at 24 h. Splenic platelet localization was decreased by 3 h following trauma. Pulmonary platelet localization was increased at all times following trauma. It is concluded that the posttrauma state is associated with a defect in the reticuloendothelial system clearance of altered platelets, which may augment embolization of platelets in the lung.

  8. Intercalibration of mussel Mytilus edulis clearance rate measurements

    NARCIS (Netherlands)

    Kjerulf Petersen, J.; Bougrier, S.; Smaal, A.C.; Garen, P.; Robert, S.; Larsen, J.E.N.; Brummelhuis, E.B.M.

    2004-01-01

    Clearance rate (CR) was measured in blue mussels Mytilus edulis L. from Aiguillon Bay and the Oosterschelde using 3 different methods: the flow-through method, the bio-deposition method and the indirect or clearance method. CR differed significantly as a function of the method used and of the origin

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living longer and ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  10. DOD PERSONNEL CLEARANCES: Additional OMB Actions Are Needed to Improve the Security Clearance Process

    National Research Council Canada - National Science Library

    2006-01-01

    Our independent analysis of timeliness data showed that industry personnel contracted to work for the federal government waited more than one year on average to receive top secret clearances, longer...

  11. Methods and apparatus for controlling rotary machines

    Science.gov (United States)

    Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Barnes, Gary R [Delanson, NY; Fric, Thomas Frank [Greer, SC; Lyons, James Patrick Francis [Niskayuna, NY; Pierce, Kirk Gee [Simpsonville, SC; Holley, William Edwin [Greer, SC; Barbu, Corneliu [Guilderland, NY

    2009-09-01

    A control system for a rotary machine is provided. The rotary machine has at least one rotating member and at least one substantially stationary member positioned such that a clearance gap is defined between a portion of the rotating member and a portion of the substantially stationary member. The control system includes at least one clearance gap dimension measurement apparatus and at least one clearance gap adjustment assembly. The adjustment assembly is coupled in electronic data communication with the measurement apparatus. The control system is configured to process a clearance gap dimension signal and modulate the clearance gap dimension.

  12. Enhanced efficacy of sequential administration of Albendazole for the clearance of Wuchereria bancrofti infection: Double blind RCT.

    Science.gov (United States)

    De Britto, R L; Vanamail, P; Sankari, T; Vijayalakshmi, G; Das, L K; Pani, S P

    2015-06-01

    Till today, there is no effective treatment protocol for the complete clearance of Wuchereria bancrofti (W.b) infection that causes secondary lymphoedema. In a double blind randomized control trial (RCT), 146 asymptomatic W. b infected individuals were randomly assigned to one of the four regimens for 12 days, DEC 300 mg + Doxycycline 100 mg coadministration or DEC 300 mg + Albendazole 400 mg co-administration or DEC 300 mg + Albendazole 400 mg sequential administration or control regimen DEC 300 mg and were followed up at 13, 26 and 52 weeks post-treatment for the clearance of infection. At intake, there was no significant variation in mf counts (F(3,137)=0.044; P=0.988) and antigen levels (F(3,137)=1.433; P=0.236) between the regimens. Primary outcome analysis showed that DEC + Albendazole sequential administration has an enhanced efficacy over DEC + Albendazole co-administration (80.6 Vs 64.7%), and this regimen is significantly different when compared to DEC + doxycycline co-administration and control (PAlbendazole sequential administration appears to be a better option for rapid clearance of W. b microfilariae in 13 weeks time. (Clinical trials.gov identifier - NCT02005653).

  13. Assessment of renal function with the Tc-99m-MAG3 clearance

    International Nuclear Information System (INIS)

    Keske, U.; Corcles, M.; Andreessen, R.; Wilfling, M.; Roll, D.; Gahl, G.; Felix, R.

    1990-01-01

    This paper evaluates the applicability of the 99m-Tc-mercaptoacetyle-triglycine (MAG3) clearance for the documentation of renal function. Renal clearance was measured with the method of Tauxe in 699 patients during routine renal scintigraphy with 80 MBq of 99mTc-MAG3. Serum creatinine level and MAG3 clearance show an inverse correlation. Patients with an elevated serum creatinine level constantly have a lowered MAG3 clearance and vice versa. For creatinine values lower than 1.8 mg/dL, minor changes in creatinine level are accompanied by large changes in MAG3 clearance. Age (in years) dependence of MAG3 clearance was evaluated in 487 patients who showed no evidence of impaired renal function

  14. 77 FR 19307 - Renewal of Information Collection; OMB Control Number 1040-0001, DOI Programmatic Clearance for...

    Science.gov (United States)

    2012-03-30

    ... solicit customer feedback on Government services and using such feedback regularly to make service..., policies. This area focuses on obtaining feedback from customers regarding fairness, adequacy, and... Number 1040-0001, DOI Programmatic Clearance for Customer Satisfaction Surveys AGENCY: Department of the...

  15. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  16. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    shanker

    have been identified [1,3]. These include stone characteristics, the type of lithotripter used, LPC anatomy and body habitus. For iso- lated LPC stones, the pelvicalyceal angle, infundibulum length and width are considered important determinants for stone clearance. The impact of body habitus on stone clearance has so far ...

  17. Sound source location in cavitating tip vortices

    International Nuclear Information System (INIS)

    Higuchi, H.; Taghavi, R.; Arndt, R.E.A.

    1985-01-01

    Utilizing an array of three hydrophones, individual cavitation bursts in a tip vortex could be located. Theoretically, four hydrophones are necessary. Hence the data from three hydrophones are supplemented with photographic observation of the cavitating tip vortex. The cavitation sound sources are found to be localized to within one base chord length from the hydrofoil tip. This appears to correspond to the region of initial tip vortex roll-up. A more extensive study with a four sensor array is now in progress

  18. Study of tip loss corrections using CFD rotor computations

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zhu, Wei Jun; Sørensen, Jens Nørkær

    2014-01-01

    Tip loss correction is known to play an important role for engineering prediction of wind turbine performance. There are two different types of tip loss corrections: tip corrections on momentum theory and tip corrections on airfoil data. In this paper, we study the latter using detailed CFD...... computations for wind turbines with sharp tip. Using the technique of determination of angle of attack and the CFD results for a NordTank 500 kW rotor, airfoil data are extracted and a new tip loss function on airfoil data is derived. To validate, BEM computations with the new tip loss function are carried out...... and compared with CFD results for the NordTank 500 kW turbine and the NREL 5 MW turbine. Comparisons show that BEM with the new tip loss function can predict correctly the loading near the blade tip....

  19. [TIPS

    Science.gov (United States)

    Brazzini, Augusto; Carrillo, Alvaro; Cantella, Raúl

    1998-01-01

    Esophageal hemorrage due to variceal bleeding in cirrhotic patients represents a serious problem for the physician in charge, especially in this country where liver transplants are inexistent; and also, it is a drama for the patient and its familly. We propose here the Transjugular Intrahepatic Portosystemic Shunt (TIPS). Twenty one patients were part of a study where 23 TIPS were placed, observing an immediate improval in 18 of them, a rebleeding in 2, within the first 24 and 48 hours. An embolization of the coronary veins was performed in the procedure in 15 patients, and a second intervention due to rebleeding in 2 of them. In the latter patients, the embolization of the coronary veins was rutinary.The survival of the patients has been outstanding.We conclude that this interventional procedure is a worldwide reality in the treatment of esophageal hemorrage by variceal bleeding due to portal hipertension, and it does not cut down the probability of liver transplant, unfortunately inexistent in our country. This procedure results in a low morbimortality with an adequate quality of life.

  20. Dynamic characteristics analysis of deployable space structures considering joint clearance

    Science.gov (United States)

    Li, Tuanjie; Guo, Jian; Cao, Yuyan

    2011-04-01

    The clearance in joints influences the dynamic stability and the performance of deployable space structures (DSS). A virtual experimental modal analysis (VEMA) method is proposed to deal with the effects of joint clearance and link flexibility on the dynamic characteristics of the DSS in this paper. The focus is on the finite element modeling of the clearance joint, VEMA and the modal parameters identification of the DSS. The finite element models (FEM) of the clearance joint and the deployable structure are established in ANSYS. The transient dynamic analysis is conducted to provide the time history data of excitation and response for the VEMA. The fast Fourier transform (FFT) technique is used to transform the data from time domain to frequency domain. The frequency response function is calculated to identify the modal parameters of the deployable structure. Experimental verification is provided to indicate the VEMA method is both a cost and time efficient approach to obtain the dynamic characteristics of the DSS. Finally, we analyze the effects of clearance size and gravity on the dynamic characteristics of the DSS. The analysis results indicate that the joint clearance and gravity strongly influence the dynamic characteristics of the DSS.

  1. A simple method to prevent hard X-ray-induced preheating effects inside the cone tip in indirect-drive fast ignition implosions

    International Nuclear Information System (INIS)

    Liu, Dongxiao; Shan, Lianqiang; Zhou, Weimin; Wu, Yuchi; Zhu, Bin; Zhang, Feng; Bi, Bi; Zhang, Bo; Zhang, Zhimeng; Shui, Min; He, Yingling; Gu, Yuqiu; Zhang, Baohan; Peng, Xiaoshi; Xu, Tao; Wang, Feng; Yang, Zhiwen; Chen, Tao; Chen, Li; Chen, Ming

    2016-01-01

    During fast-ignition implosions, preheating of inside the cone tip caused by hard X-rays can strongly affect the generation and transport of hot electrons in the cone. Although indirect-drive implosions have a higher implosion symmetry, they cause stronger preheating effects than direct-drive implosions. To control the preheating of the cone tip, we propose the use of indirect-drive fast-ignition targets with thicker tips. Experiments carried out at the ShenGuang-III prototype laser facility confirmed that thicker tips are effective for controlling preheating. Moreover, these results were consistent with those of 1D radiation hydrodynamic simulations.

  2. A simple method to prevent hard X-ray-induced preheating effects inside the cone tip in indirect-drive fast ignition implosions

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Dongxiao; Shan, Lianqiang; Zhou, Weimin; Wu, Yuchi; Zhu, Bin; Zhang, Feng; Bi, Bi; Zhang, Bo; Zhang, Zhimeng; Shui, Min; He, Yingling; Gu, Yuqiu, E-mail: yqgu@caep.cn; Zhang, Baohan [Science and Technology on Plasma Physics Laboratory, China Academy of Engineering Physics, Mianyang 621900 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Peng, Xiaoshi; Xu, Tao; Wang, Feng; Yang, Zhiwen; Chen, Tao; Chen, Li; Chen, Ming [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); and others

    2016-06-15

    During fast-ignition implosions, preheating of inside the cone tip caused by hard X-rays can strongly affect the generation and transport of hot electrons in the cone. Although indirect-drive implosions have a higher implosion symmetry, they cause stronger preheating effects than direct-drive implosions. To control the preheating of the cone tip, we propose the use of indirect-drive fast-ignition targets with thicker tips. Experiments carried out at the ShenGuang-III prototype laser facility confirmed that thicker tips are effective for controlling preheating. Moreover, these results were consistent with those of 1D radiation hydrodynamic simulations.

  3. CPAP Tips

    Medline Plus

    Full Text Available ... opinion count. Sign in ... and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ...

  4. The tonoplast intrinsic aquaporin (TIP) subfamily of Eucalyptus grandis: Characterization of EgTIP2, a root-specific and osmotic stress-responsive gene.

    Science.gov (United States)

    Rodrigues, Marcela I; Bravo, Juliana P; Sassaki, Flávio T; Severino, Fábio E; Maia, Ivan G

    2013-12-01

    Aquaporins have important roles in various physiological processes in plants, including growth, development and adaptation to stress. In this study, a gene encoding a root-specific tonoplast intrinsic aquaporin (TIP) from Eucalyptus grandis (named EgTIP2) was investigated. The root-specific expression of EgTIP2 was validated over a panel of five eucalyptus organ/tissues. In eucalyptus roots, EgTIP2 expression was significantly induced by osmotic stress imposed by PEG treatment. Histochemical analysis of transgenic tobacco lines (Nicotiana tabacum SR1) harboring an EgTIP2 promoter:GUS reporter cassette revealed major GUS staining in the vasculature and in root tips. Consistent with its osmotic-stress inducible expression in eucalyptus, EgTIP2 promoter activity was up-regulated by mannitol treatment, but was down-regulated by abscisic acid. Taken together, these results suggest that EgTIP2 might be involved in eucalyptus response to drought. Additional searches in the eucalyptus genome revealed the presence of four additional putative TIP coding genes, which could be individually assigned to the classical TIP1-5 groups. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. Inference of type-specific HPV transmissibility, progression and clearance rates: a mathematical modelling approach.

    Directory of Open Access Journals (Sweden)

    Helen C Johnson

    Full Text Available Quantifying rates governing the clearance of Human Papillomavirus (HPV and its progression to clinical disease, together with viral transmissibility and the duration of naturally-acquired immunity, is essential in estimating the impact of vaccination programmes and screening or testing regimes. However, the complex natural history of HPV makes this difficult. We infer the viral transmissibility, rate of waning natural immunity and rates of progression and clearance of infection of 13 high-risk and 2 non-oncogenic HPV types, making use of a number of rich datasets from Sweden. Estimates of viral transmissibility, clearance of initial infection and waning immunity were derived in a Bayesian framework by fitting a susceptible-infectious-recovered-susceptible (SIRS transmission model to age- and type-specific HPV prevalence data from both a cross-sectional study and a randomised controlled trial (RCT of primary HPV screening. The models fitted well, but over-estimated the prevalence of four high-risk types with respect to the data. Three of these types (HPV-33, -35 and -58 are among the most closely related phylogenetically to the most prevalent HPV-16. The fourth (HPV-45 is the most closely related to HPV-18; the second most prevalent type. We suggest that this may be an indicator of cross-immunity. Rates of progression and clearance of clinical lesions were additionally estimated from longitudinal data gathered as part of the same RCT. Our estimates of progression and clearance rates are consistent with the findings of survival analysis studies and we extend the literature by estimating progression and clearance rates for non-16 and non-18 high-risk types. We anticipate that such type-specific estimates will be useful in the parameterisation of further models and in developing our understanding of HPV natural history.

  6. Clearance of 99mTc-labeled albumin from lungs in anesthetized guinea pigs

    International Nuclear Information System (INIS)

    Connelly, J.C.; Peterson, B.T.

    1993-01-01

    Gamma imaging was used to measure the rate of clearance of aerosolized 99m Tc-human serum albumin (HSA) from the lungs of control guinea pigs and guinea pigs that received increased lung inflation or lung injury. Anesthetized guinea pigs were ventilated for 6 min with an aerosol of HSA and the radioactivity in the chest was monitored for 2 h with a gamma camera to determine whether the clearance rate would be a reliable assessment of lung epithelial permeability. Increased lung volumes were effected by application of 5 or 7 cm H 2 O positive end-expired pressure (5-PEEP and 7-PEEP, respectively). Lung injury was induced either by intravenous oleic acid (OA, 27-73 μl/kg) or inhalation of nitrogen dioxide (NO 2 , 80-100 ppm) for 2 h. Postmortem extravascular lung water volume (EVLW) provided an assessment of the degree of lung injury. Tracer clearance rates in animals receiving 5 or 7 cm H 2 O PEEP were not significantly different from controls (K = 0.15 ± 0.05 and 0.24 ± 0.10 vs 0.12 ± 0.03%/min, respectively, p > .05). Animals exposed to NO 2 had faster tracer clearance rates (K = 0.33 ± 0.21%/min, p 2 -exposed guinea pigs correlated well with injury as assessed by EVLW (r = .93, p 2 O PEEP (K = 0.58 ± 0.41%/min, EVLW = 8.1 ± 0.8 mL/g dry lung tissue, p < .05), but there was no correlation between these parameters in this injury model. It is concluded that imaging of the disappearance of radiolabeled HSA in the guinea pig can be a useful index of lung epithelial permeability, but this technique is limited to certain models of lung injury. 33 refs

  7. 32 CFR 644.522 - Clearance of military scrap.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation or...

  8. Tip Induced Motion of Adatoms on Metal Surfaces

    International Nuclear Information System (INIS)

    Kuerpick, U.; Rahman, T.S.

    1999-01-01

    From total energy calculations we show that for certain tip-adatom separations the activation barrier for the adatom to move towards the tip disappears and the adatom experiences an attractive force in the direction of the tip. For a Cu adatom at a (100) microfaceted step on Cu(111) this happens at a lateral separation of about one lattice constant, in agreement with recent experimental findings. Simultaneously, the activation barrier in the direction away from the tip increases significantly. The details of the changes in the potential energy surface induced by the tip are found to depend on the characteristics of the tip apex and its height above the adatom. copyright 1999 The American Physical Society

  9. Applicability of Clearance Automatic Laser Inspection System to Clearance Measurement of Concrete Segments

    International Nuclear Information System (INIS)

    Sasaki, M.; Ogino, H.; Hattori, T.

    2009-01-01

    In the decommissioning of a nuclear power plant, large amounts of metal scrap and concrete segments require disposal when dismantling the nuclear reactor and surrounding facilities. When their activity level is negligible or sufficiently small, they can be regarded as general industrial waste. To distinguish between radioactive and nonradioactive materials, the clearance level for each radionuclide has been determined in units of activity concentration. These clearance levels are indicated in the International Atomic Energy Agency (IAEA) Safety Standards Series No. RS-G-1.7. The Japanese regulatory authority decided in 2005 to adopt the values given in RS-G-1.7 as clearance levels in legislation. Recently, a Clearance Automatic Laser Inspection System (CLALIS) has been developed utilizing gamma-ray measurement, automatic laser shape measurement and Monte Carlo calculation. CLALIS comprises four laser scanners and eight large plastic scintillation detectors surrounded by a 5-cm-thick lead shield. Using three-dimensional (3D) laser scanning, a measurement target, which is placed on the measuring tray, is represented as a dot image. The dot image is converted into voxels after noise removal, and is written in MCNP (A General Monte Carlo N-Particle Transport Code System) input files. When the gamma-ray measurement is carried out, the MCNP calculations are also carried out to obtain the calibration factor and background (BG) correction factors. For the clearance measurement of concrete segments, the effect of gamma-rays from natural radionuclides in the measurement target, such as K-40 and the radioactive decay products of Th-232 and U-238, should be taken into account to ensure adequate waste management. Since NE102A plastic scintillation detectors are used for gamma-ray measurement in CLALIS, it is impossible to distinguish between the count rates of natural radionuclides and contaminants on the basis of gamma-ray energy information. To overcome this problem, the

  10. TIP maker and TIP marker; EB1 as a master controller of microtubule plus ends.

    Science.gov (United States)

    Vaughan, Kevin T

    2005-10-24

    The EB1 protein is a member of the exciting and enigmatic family of microtubule (MT) tip-tracking proteins. EB1 acts as an exquisite marker of dynamic MT plus ends in some cases, whereas in others EB1 is thought to directly dictate the behavior of the plus ends. How EB1 differentiates between these two roles remains unclear; however, a growing list of interactions between EB1 and other MT binding proteins suggests there may be a single mechanism. Adding another layer of complexity to these interactions, two studies published in this issue implicate EB1 in cross-talk between mitotic MTs and between MTs and actin filaments (Goshima et al., p. 229; Wu et al., p. 201). These results raise the possibility that EB1 is a central player in MT-based transport, and that the activity of MT-binding proteins depends on their ability or inability to interact with EB1.

  11. Arctic tipping points in an Earth system perspective.

    Science.gov (United States)

    Wassmann, Paul; Lenton, Timothy M

    2012-02-01

    We provide an introduction to the volume The Arctic in the Earth System perspective: the role of tipping points. The terms tipping point and tipping element are described and their role in current science, general debates, and the Arctic are elucidated. From a wider perspective, the volume focuses upon the role of humans in the Arctic component of the Earth system and in particular the envelope for human existence, the Arctic ecosystems. The Arctic climate tipping elements, the tipping elements in Arctic ecosystems and societies, and the challenges of governance and anticipation are illuminated through short summaries of eight publications that derive from the Arctic Frontiers conference in 2011 and the EU FP7 project Arctic Tipping Points. Then some ideas based upon resilience thinking are developed to show how wise system management could ease pressures on Arctic systems in order to keep them away from tipping points.

  12. Clearance level and industrial waste management

    International Nuclear Information System (INIS)

    Asano, Toichi

    1999-01-01

    Defining the clearance level enables the radioactive waste with lower radioactivity than a certain level to be the general industrial waste and therefore consideration for public acceptance is essential. For this, it is necessary to understand laws concerning not only atomic power and radioactivity but also disposal and cleaning of general waste. It is also necessary that the waste below the clearance level should be as much as possible handled in the modern common concept of recycling of resources. In 1996, the weight of industrial waste was about 400 million tons, of which 40% was disposed by burning and dehydration, 39% was re-used and 21% was subjected to the final disposal like reclamation. Reduction, re-use and recycling of the generated waste are required for making the society with recycling of resources. Scrap concrete materials below the clearance level of 0.6 million tons are estimated to be generated by dismantling the light water reactor of 1 million kW output and profitable technology for recycling the scrap is under investigation. (K.H.)

  13. Factors Associated with Spontaneous Clearance of Hepatitis C Virus in Chinese Population

    Directory of Open Access Journals (Sweden)

    Fei Kong

    2014-01-01

    Full Text Available Hepatitis C virus (HCV infections spontaneously clear in approximately 15–45% of infected individuals. Factors which influence spontaneous HCV clearance remain to be identified. The purpose of the present study was to identify variables associated with spontaneous HCV clearance in a referred population of Chinese patients. The prevalence of host, viral, and environmental factors known to influence the outcome of HCV infections was compared in 92 HCV spontaneous clearance subjects and 318 HCV persistent infection subjects. Univariate and multivariate analyses were performed to identify those factors associated with spontaneous HCV clearance. In univariate analysis, female gender, a history of icteric hepatitis, serologic evidence of concurrent HBV infection, and rs12979860 CC genotype were positively associated with spontaneous HCV clearance, while alcohol consumption was negatively associated with clearance. In multivariate analysis, female gender, a history of icteric hepatitis, concurrent HBV infection, and rs12979860 CC genotype remained independent variables associated with spontaneous HCV clearance. Spontaneous HCV clearance is more likely to occur in females, subjects with a history of icteric hepatitis, HBV coinfections, and those with the rs12979860 CC genotype.

  14. Tips for Postpartum Dads and Partners

    Science.gov (United States)

    ... Blues: Partners Interview with Wade Bowen Coping with Suicide & Loss Tips for Postpartum Dads and Partners Pregnancy and postpartum mood and anxiety disorders affect the whole family. Here are some tips ...

  15. Tipping Point

    Medline Plus

    Full Text Available ... fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash format. Almost ... accidents involving young children and furniture, appliance and tv tip-overs. The force of a large television ...

  16. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely and effectively use your CPAP device. Category Education License Standard YouTube License Show more Show ...

  17. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  18. Tipping Point

    Medline Plus

    Full Text Available ... of a large television falling from tipping furniture can be staggering. A 50 lb. TV falls with ... story of a building. That kind of impact can kill a child or cause severe injuries. About ...

  19. Direct Fabrication of Carbon Nanotubes STM Tips by Liquid Catalyst-Assisted Microwave Plasma-Enhanced Chemical Vapor Deposition

    Directory of Open Access Journals (Sweden)

    Fa-Kuei Tung

    2009-01-01

    Full Text Available Direct and facile method to make carbon nanotube (CNT tips for scanning tunneling microscopy (STM is presented. Cobalt (Co particles, as catalysts, are electrochemically deposited on the apex of tungsten (W STM tip for CNT growth. It is found that the quantity of Co particles is well controlled by applied DC voltage, concentration of catalyst solution, and deposition time. Using optimum growth condition, CNTs are successfully synthesized on the tip apex by catalyst-assisted microwave-enhanced chemical vapor deposition (CA-MPECVD. A HOPG surface is clearly observed at an atomic scale using the present CNT-STM tip.

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage ...

  1. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  2. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, Anne Cathrine Roslev

    1984-01-01

    we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  3. Using Terrestrial Laser Scanners to Calculate and Map Vertical Bridge Clearance

    Science.gov (United States)

    Zhang, C.; Arditi, D.; Chen, Z.

    2013-08-01

    The vertical clearance of a bridge over a highway is important in preventing oversized vehicles from hitting the bridge. The vertical clearance of a bridge is traditionally measured by using surveying equipment such as leveling rods and total stations. Typically, measurements are taken at multiple locations in order to determine the minimum vertical clearance under the bridge. This process is time and labor consuming. Also, these measurements may not be accurate because of the traffic, the uneven surface, and the reading error caused by the surveyor. Additionally, when one is faced with a multitude of reports especially in large projects with multiple ramps and bridges, it is not easy and it often takes a long time to find the bridge under study. This research provides a highly accurate measurement of the vertical bridge clearance by using terrestrial laser scanners. The clearance can be measured in the office by processing the collected point cloud data. The minimum vertical clearance is easily identified and the measurement is visualized and geo-referenced. An approach to reduce data noise caused by traffic is also introduced in this study. In addition, to help reduce the confusion of finding the bridge under study and to facilitate access to the clearance data, the clearance measurements are geo-referenced to an online mapping system. This system allows access to the final deliverable very easily through a single web portal. Finally, Illinois Department of Transportation's Circle Interchange is used to demonstrate this new method.

  4. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely and effectively use your CPAP device. Category ... Ambulance Service 21,588 views 4:34 Obstructive Sleep Apnea ...

  5. Tipping Point

    Medline Plus

    Full Text Available ... third story of a building. That kind of impact can kill a child or cause severe injuries. ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit ...

  6. Photonic jet etching: Justifying the shape of optical fiber tip

    Science.gov (United States)

    Abdurrochman, Andri; Zelgowski, Julien; Lecler, Sylvain; Mermet, Frédéric; Tumbelaka, Bernard; Fontaine, Joël

    2016-02-01

    Photonic jet (PJ) is a low diverging and highly concentrated beam in the shadow side of dielectric particle (cylinder or sphere). The concentration can be more than 200 times higher than the incidence wave. It is a non-resonance phenomenon in the near-field can propagate in a few wavelengths. Many potential applications have been proposed, including PJ etching. Hence, a guided-beam is considered increasing the PJ mobility control. While the others used a combination of classical optical fibers and spheres, we are concerned on a classical optical fiber with spherical tip to generate the PJ. This PJ driven waveguide has been realized using Gaussian mode beam inside the core. It has different variable parameters compared to classical PJ, which will be discussed in correlation with the etching demonstrations. The parameters dependency between the tip and PJ properties are complex; and theoretical aspect of this interaction will be exposed to justify the shape of our tip and optical fiber used in our demonstrations. Methods to achieve such a needed optical fiber tip will also be described. Finally the ability to generate PJ out of the shaped optical fiber will be experimentally demonstrated and the potential applications for material processing will be exposed.

  7. Continuum damage mechanics analysis of crack tip zone

    International Nuclear Information System (INIS)

    Yinchu, L.; Jianping, Z.

    1989-01-01

    The crack tip field and its intensity factor play an important role in fracture mechanics. Generally, the damage such as microcracks, microvoids etc. will initiate and grow in materials as the cracked body is subjected to external loadings, especially in the crack tip zone. The damage evolution will load to the crack tip damage field and the change of the stress, strain and displacement fields of cracks tip zone. In this paper, on the basis of continuum damage mechanics, the authors have derived the equations which the crack tip field and its intensity factor must satisfy in a loading process, calculated the angle distribution curves of stress, strain and displacement fields in a crack tip zone and have compared them with the corresponding curves of HRR field and linear elastic field in undamaged materials. The equations of crack tip field intensity factors have been solved and its solutions give the variation of the field intensity factors with the loading parameter

  8. Tip enhancement

    CERN Document Server

    Kawata, Satoshi

    2007-01-01

    This book discusses the recent advances in the area of near-field Raman scattering, mainly focusing on tip-enhanced and surface-enhanced Raman scattering. Some of the key features covered here are the optical structuring and manipulations, single molecule sensitivity, analysis of single-walled carbon nanotubes, and analytic applications in chemistry, biology and material sciences. This book also discusses the plasmonic materials for better enhancement, and optical antennas. Further, near-field microscopy based on second harmonic generation is also discussed. Chapters have been written by some of the leading scientists in this field, who present some of their recent work in this field.·Near-field Raman scattering·Tip-enhanced Raman spectroscopy·Surface-enhanced Raman spectroscopy·Nano-photonics·Nanoanalysis of Physical, chemical and biological materials beyond the diffraction limits·Single molecule detection

  9. Optical fiber meta-tips

    Science.gov (United States)

    Principe, Maria; Micco, Alberto; Crescitelli, Alessio; Castaldi, Giuseppe; Consales, Marco; Esposito, Emanuela; La Ferrara, Vera; Galdi, Vincenzo; Cusano, Andrea

    2016-04-01

    We report on the first example of a "meta-tip" configuration that integrates a metasurface on the tip of an optical fiber. Our proposed design is based on an inverted-Babinet plasmonic metasurface obtained by patterning (via focused ion beam) a thin gold film deposited on the tip of an optical fiber, so as to realize an array of rectangular aperture nanoantennas with spatially modulated sizes. By properly tuning the resonances of the aperture nanoantennas, abrupt variations can be impressed in the field wavefront and polarization. We fabricated and characterized several proof-of-principle prototypes operating an near-infrared wavelengths, and implementing the beam-steering (with various angles) of the cross-polarized component, as well as the excitation of surface waves. Our results pave the way to the integration of the exceptional field-manipulation capabilities enabled by metasurfaces with the versatility and ubiquity of fiber-optics technological platforms.

  10. CPAP Tips

    Medline Plus

    Full Text Available ... Get YouTube Red. Working... Not now Try it free Find out why Close CPAP Tips from FDA ... safely and effectively use your CPAP device. Category Education License Standard YouTube License Show more Show less ...

  11. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ... Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign in to add ...

  12. Surface tension-induced high aspect-ratio PDMS micropillars with concave and convex lens tips

    KAUST Repository

    Li, Huawei; Fan, Yiqiang; Yi, Ying; Foulds, Ian G.

    2013-01-01

    This paper reports a novel method for the fabrication of 3-dimensional (3D) Polydimethylsiloxane (PDMS) micropillars with concave and convex lens tips in a one-step molding process, using a CO2 laser-machined Poly(methyl methacrylate) (PMMA) mold with through holes. The PDMS micropillars are 4 mm high and have an aspect ratio of 251. The micropillars are formed by capillary force drawing up PDMS into the through hole mold. The concave and convex lens tips of the PDMS cylindrical micropillars are induced by surface tension and are controllable by changing the surface wetting properties of the through holes in the PMMA mold. This technique eliminates the requirements of expensive and complicated facilities to prepare a 3D mold, and it provides a simple and rapid method to fabricate 3D PDMS micropillars with controllable dimensions and tip shapes. © 2013 IEEE.

  13. Surface tension-induced high aspect-ratio PDMS micropillars with concave and convex lens tips

    KAUST Repository

    Li, Huawei

    2013-04-01

    This paper reports a novel method for the fabrication of 3-dimensional (3D) Polydimethylsiloxane (PDMS) micropillars with concave and convex lens tips in a one-step molding process, using a CO2 laser-machined Poly(methyl methacrylate) (PMMA) mold with through holes. The PDMS micropillars are 4 mm high and have an aspect ratio of 251. The micropillars are formed by capillary force drawing up PDMS into the through hole mold. The concave and convex lens tips of the PDMS cylindrical micropillars are induced by surface tension and are controllable by changing the surface wetting properties of the through holes in the PMMA mold. This technique eliminates the requirements of expensive and complicated facilities to prepare a 3D mold, and it provides a simple and rapid method to fabricate 3D PDMS micropillars with controllable dimensions and tip shapes. © 2013 IEEE.

  14. Note: Microelectrode-shielding tip for scanning probe electron energy spectroscopy

    Science.gov (United States)

    Huang, Wei; Li, Zhean; Xu, Chunkai; Liu, Jian; Xu, Chunye; Chen, Xiangjun

    2018-04-01

    We report a novel microelectrode-shielding tip (ME tip) for scanning probe electron energy spectroscopy (SPEES). The shielding effect of this tip is studied through comparing the detection efficiency with the normal tip by both experiment and simulation. The results show that the backscattering count rate detected by the SPEES instrument using the normal tip begins to decrease as the tip approaches to the sample surface within 21 μm, while that using the ME tip only starts to drop off within 1 μm. This indicates that the electron energy spectra can be measured with the ME tip at a much closer tip-sample distance. Furthermore, it is also demonstrated that the ME tip can be used to obtain topography of the sample surface in situ simultaneously.

  15. Injector tip for an internal combustion engine

    Science.gov (United States)

    Shyu, Tsu Pin; Ye, Wen

    2003-05-20

    This invention relates to a the tip structure of a fuel injector as used in a internal combustion engine. Internal combustion engines using Homogeneous Charge Compression Ignition (HCCI) technology require a tip structure that directs fuel spray in a downward direction. This requirement necessitates a tip design that is capable of withstanding mechanical stresses associated with the design.

  16. Modification of AFM Tips for Facilitating Picking-up of Nanoparticles

    International Nuclear Information System (INIS)

    Peng, Wang; Hai-Jun, Yang; Hua-Bin, Wang; Hai, Li; Xin-Yan, Wang; Ying, Wang; Jun-Hong, Lü; Bin, Li; Yi, Zhang; Jun, Hu

    2008-01-01

    The radius of atomic force microscope (AFM) tip is a key factor that influences nonspecific interactions between AFM tip and nanoparticles. Generally, a tip with larger radius contributes to a higher efficiency of picking up nanoparticles. We provide two methods for modifying the AFM tip: one is to wear a tip apex on a solid substrate and the other is to coat a tip with poly (dimethylsiloxane) (PDMS). Both the approaches can enhance the adhesion force between the tip and nanoparticles by increasing tip radius. The experimental results show that a modified tip, compared to an unmodified one, achieves six-fold efficiency improvement in the capture of targeted colloidal gold nanoparticles. (general)

  17. Respiratory clearance of aerosolized radioactive solutes of varying molecular weight

    International Nuclear Information System (INIS)

    Huchon, G.J.; Montgomery, A.B.; Lipavsky, A.; Hoeffel, J.M.; Murray, J.F.

    1987-01-01

    To determine the influence of varying molecular weight (mol wt) on respiratory clearance of aerosolized solutes, we studied eight radiopharmaceuticals, each administered to four dogs: sodium /sup 99m/Tc pertechnetate (TcO4), /sup 99m/Tc glucoheptonate ([/sup 99m/Tc]GH), 51Cr-ethylenedinitrotetraacetate ([51Cr]EDTA), /sup 99m/Tc diethylenetriaminepentaacetate ([99mTc] DTPA), 111 In diethylenetriaminepentaacetate ([ 111 In]DTPA), 67 Ga desferoxaminemesylate ([ 67 Ga]DFOM), /sup 99m/Tc dextran ([/sup 99m/Tc]DX) and 111 In transferrin ([ 111 In]TF). After aerosolization (0.8 m MMD, 2.4 GSD), clearance was determined for 30 min and then corrected by intravenous injection for nonairspace radioactivity. In-TF clearance (0.11 +/- 0.10%/min) was lower than TcO4 (6.32 +/- 0.62%/min), [/sup 99m/Tc]GH (1.50 +/- 0.37%/min), [ 51 Cr]EDTA (2.38 +/- 1.02%/min), [/sup 99m/Tc]DTPA (3.51 +/- 0.40%/min), [ 111 In]DTPA (2.35 +/- 0.42%/min), [ 67 Ga] DFOM (1.99 +/- 0.49%/min) and [/sup 99m/Tc]DX (1.81 +/- 0.75%/min) clearances (p less than 0.001). TcO4 clearance was higher than others (p less than 0.001). Technetium binding to DX was unsatisfactory; aerosolization caused unbinding from DTPA. We conclude that respiratory clearance of large mol wt solutes within 30 min is negligible and, that clearance of molecules between 347-5099 daltons differs greatly, suggesting that binding and/or intrapulmonary retention affect transfer

  18. Clearance of surface-contaminated objects from the controlled area of a nuclear facility. Application of the SUDOQU methodology

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.; Mommaert, C. [Bel V, Brussels (Belgium); Dillen, T. van [National Institute for Public Health and the Environment (RIVM), Bilthoven (Netherlands)

    2018-01-15

    The lack of clearly defined surface-clearance levels in the Belgian regulation led Bel V to start a collaboration with the Dutch National Institute for Public Health and the Environment (RIVM) to evaluate the applicability of the SUDOQU methodology for the derivation of nuclide-specific surface-clearance criteria for objects released from nuclear facilities. SUDOQU is a methodology for the dose assessment of exposure to a surface-contaminated object, with the innovative assumption of a time-dependent surface activity whose evolution is influenced by removal and deposition mechanisms. In this work, calculations were performed to evaluate the annual effective dose resulting from the use of a typical office item, e.g. a bookcase. Preliminary results allow understanding the interdependencies between the model's underlying mechanisms, and show a strong sensitivity to the main input parameters. The results were benchmarked against those from a model described in Radiation Protection 101, to investigate the impact of the model's main assumptions. Results of the two models were in good agreement. The SUDOQU methodology appears to be a flexible and powerful tool, suitable for the proposed application. Therefore, the project will be extended to more generic study cases, to eventually develop surface-clearance levels applicable to objects leaving nuclear facilities.

  19. CPAP Tips

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close CPAP Tips from ...

  20. Direct calculation of wind turbine tip loss

    DEFF Research Database (Denmark)

    Wood, D.H.; Okulov, Valery; Bhattacharjee, D.

    2016-01-01

    . We develop three methods for the direct calculation of the tip loss. The first is the computationally expensive calculation of the velocities induced by the helicoidal wake which requires the evaluation of infinite sums of products of Bessel functions. The second uses the asymptotic evaluation......The usual method to account for a finite number of blades in blade element calculations of wind turbine performance is through a tip loss factor. Most analyses use the tip loss approximation due to Prandtl which is easily and cheaply calculated but is known to be inaccurate at low tip speed ratio...

  1. Comparison of German and international clearance regulations - chances and limits for harmonization

    International Nuclear Information System (INIS)

    Thierfeldt, S.; Schartmann, F.

    2005-01-01

    The regulations on clearance in the German nuclear regulatory framework (especially sect. 29 and Annexes III and IV of the Radiation Protection Ordinance) are comprehensive and well founded. Germany has developed some of its clearance levels in advance of recommendations issued by the EC. Therefore, there are differences between the German and international clearance regulations. That has been investigated by a working group on clearance of the German Commission on Radiological Protection (SSK) which has performed an analysis of differences and their reasons for clearance levels in Germany and other countries (UK, The Netherlands, Sweden, USA and others). Differences can mainly be explained by country specific approaches in scenarios. Differences especially for the most relevant nuclides are not significant from a radiological point of view. The level of radiological protection (trivial dose range, a few 10 μSv/a) is guaranteed in all countries. The international discussion on the international harmonisation of clearance levels (mainly within the scope of the OECD/NEA and IAEA) can be enlightened on the basis of these results. This discussion concentrates on the question how far a harmonisation of clearance level values is actually necessary and possible. The IAEA Safety Guide RS-G-1.7 'Application of the concepts of exclusion, exemption and clearance' is of particular importance, because it proposes a set of values which might in the long-term take the role of international unconditional clearance levels. International harmonisation is only relevant for unconditional clearance of those materials, which are traded in large quantities among countries, in particular metal scrap. Harmonisation of the values to the same order of magnitude is sufficient. (orig.)

  2. Low-angled peripheral intravenous catheter tip placement decreases phlebitis.

    Science.gov (United States)

    Tanabe, Hidenori; Murayama, Ryoko; Yabunaka, Koichi; Oe, Makoto; Takahashi, Toshiaki; Komiyama, Chieko; Sanada, Hiromi

    2016-11-02

    Peripheral intravenous catheters (PIVCs) are frequently removed due to phlebitis. We hypothesized that catheters made of polyurethane, which is more flexible than Teflon, would decrease phlebitis, and that flexibility could be estimated by measuring the catheter-tip angle. Ultrasonography in two groups of patients with different catheter types was then used to compare catheter-tip angles and phlebitis. Observational studies were carried out at a medical ward in a university hospital. Infusion therapy was administered to one group of patients in 2014 using Teflon catheters (control group, n = 200), and to another group of patients in 2015 using polyurethane catheters (investigational group, n = 207). The symptoms were assessed according to a scale developed by the Infusion Nurses Society. Long-axis ultrasonography images taken immediately before catheter removal were used to measure the angle between the central line of the catheter within 2 mm from the distal point and a tangent to the vessel wall. There were no significant differences between the two groups with respect to sex, age, and medical diagnosis. In the control and investigational groups, the rates of phlebitis were 37% (73/200) and 17% (36/207), respectively (pPhlebitis occurred more frequently when the catheter-tip was placed at angle >5.8°. The frequency of phlebitis was lower in the polyurethane, in which the catheter was placed at lower angle, almost parallel to the vessel. Our results will aid in developing new catheters and in improving PIVC-securement techniques.

  3. Clearance of buildings for demolition: ways to clearance on the standing structure for covered surfaces and inaccessible areas

    International Nuclear Information System (INIS)

    Thraenert, S.; Riemann, T.

    2014-01-01

    In general terms, the TUV NORD Nuclear services encompass safety assessments, design reviews, documentation re-views and inspections. They reflect the full scope of a technical service provider in the nuclear field. In the domestic market, these services are provided for the regulator, whereas in the international market any party involved in a nuclear project is a potential customer of TUV NORD Nuclear. This implies that TUV NORD Nuclear is offering consultancy, engineering and inspection services. Regarding the clearance of buildings for demolition, there are two different possible ways for the radiological characterization. The first option is a characterization on the standing structure before demolition and the second option is the characterization of the building rubble after demolition. According to the German Radiation Protection Ordinance, buildings of decommissioned nuclear sites have to be preferentially cleared on the standing structure. If compliance with the surface specific clearance levels is achieved on the standing structure, usually the cleared buildings can be demolished and the resulting rubble may be used without any further radiological considerations. In the case of the former nuclear power plant Wuergassen the majority of the building rubble is scheduled to stay on site to serve as backfill for the building pit. As such a scenario was not considered in the radiological considerations of, e.g., the German Radiation Protection Ordinance, an additional dose calculation was carried out for Wuergassen NPP basing on its radiological characteristics to directly prove compliance with the de-minimis-concept. The radiation controlled area (RCA) of Wuergassen NPP comprises an area of about 140.000 m 2 . This area is more or less easily accessible to characterization and decontamination using, if necessary, scaffoldings or lifting platforms. Up to the beginning of 2013, compliance with the surface specific clearance levels was verified on the standing

  4. Management of Bleeding Duodenal Varices with Combined TIPS Decompression and Trans-TIPS Transvenous Obliteration Utilizing 3% Sodium Tetradecyl Sulfate Foam Sclerosis.

    Science.gov (United States)

    Saad, Wael E; Lippert, Allison; Schwaner, Sandra; Al-Osaimi, Abdullah; Sabri, Saher; Saad, Nael

    2014-01-01

    Endoscopic experience in the management of duodenal varices (DVs) is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS) or by transvenous obliteration is unresolved. In the literature, the 6-12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. This is a retrospective study (case series) of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013). TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis) from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs) and clinical outcomes (rebleeding rate and survival) were evaluated. Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally) receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days). After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6-50 months). Coils and/or metallic vascular plugs were used to augment

  5. Overview, practical tips and potential pitfalls of using automatic exposure control in CT: Siemens care dose 4D

    International Nuclear Information System (INIS)

    Soederberg, Marcus

    2016-01-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. (authors)

  6. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  7. Glymphatic clearance controls state-dependent changes in brain lactate concentration

    DEFF Research Database (Denmark)

    Lundgaard, Iben; Lu, Minh Lon; Yang, Ezra

    2017-01-01

    Brain lactate concentration is higher during wakefulness than in sleep. However, it is unknown why arousal is linked to an increase in brain lactate and why lactate declines within minutes of sleep. Here, we show that the glymphatic system is responsible for state-dependent changes in brain lacta......-lymphatic clearance. This analysis provides fundamental new insight into brain energy metabolism by demonstrating that glucose that is not fully oxidized can be exported as lactate via glymphatic-lymphatic fluid transport.......Brain lactate concentration is higher during wakefulness than in sleep. However, it is unknown why arousal is linked to an increase in brain lactate and why lactate declines within minutes of sleep. Here, we show that the glymphatic system is responsible for state-dependent changes in brain lactate...... concentration. Suppression of glymphatic function via acetazolamide treatment, cisterna magna puncture, aquaporin 4 deletion, or changes in body position reduced the decline in brain lactate normally observed when awake mice transition into sleep or anesthesia. Concurrently, the same manipulations diminished...

  8. Glymphatic clearance controls state-dependent changes in brain lactate concentration.

    Science.gov (United States)

    Lundgaard, Iben; Lu, Minh Lon; Yang, Ezra; Peng, Weiguo; Mestre, Humberto; Hitomi, Emi; Deane, Rashid; Nedergaard, Maiken

    2017-06-01

    Brain lactate concentration is higher during wakefulness than in sleep. However, it is unknown why arousal is linked to an increase in brain lactate and why lactate declines within minutes of sleep. Here, we show that the glymphatic system is responsible for state-dependent changes in brain lactate concentration. Suppression of glymphatic function via acetazolamide treatment, cisterna magna puncture, aquaporin 4 deletion, or changes in body position reduced the decline in brain lactate normally observed when awake mice transition into sleep or anesthesia. Concurrently, the same manipulations diminished accumulation of lactate in cervical, but not in inguinal lymph nodes when mice were anesthetized. Thus, our study suggests that brain lactate is an excellent biomarker of the sleep-wake cycle and increases further during sleep deprivation, because brain lactate is inversely correlated with glymphatic-lymphatic clearance. This analysis provides fundamental new insight into brain energy metabolism by demonstrating that glucose that is not fully oxidized can be exported as lactate via glymphatic-lymphatic fluid transport.

  9. Antipyrine, oxazepam, and indocyanine green clearance in patients with chronic pancreatitis and healthy subjects

    DEFF Research Database (Denmark)

    Andersen, Vibeke; Sonne, J; Larsen, S

    1999-01-01

    Hepatic drug metabolism was examined in patients with chronic pancreatitis and healthy controls by using a cocktail design with three different model compounds: antipyrine to express phase-I oxidation, oxazepam to express phase-II conjugation, and indocyanine green (ICG), a high-clearance compound....

  10. DO SLOVENIAN DEALERS USE TECHNIQUES FOR INCREASING THEIR TIPS?

    Directory of Open Access Journals (Sweden)

    Andrej Raspor

    2016-05-01

    Full Text Available In 1996 Michael Lynn introduced the idea that restaurant managers could increase tips for their waiters and thus increase turnover by training the waiters to engage tip-enhancing behaviours. Since then, the list of tip-enhancing behaviours has expanded. Therefore the potential to increase tips is more accessible. The purpose of this paper was to examine how Slovenian dealers use strategies to increase their tips. We tested fourteen techniques to increase tips. The study was carried out among 473 gaming employees, 279 of which are dealers, in the Slovenian gaming industry, in order to find out how they use these techniques and which of them can bring about an increase in their tips. The study showed that Slovenian dealers mostly do not use these techniques, and that the dealers who do use them tend to receive tips more often. The findings imply that managers and employees should be informed of these techniques in order to increase tips and their overall income. Practical implications are that we suggest that management considers these ideas for increasing flexibility and reducing the cost of work: (1 informing dealers on ways of increasing tips, (2 including the acquisition of this specific knowledge in their career plans, (3 carrying out a reform of the reward system which would include tips. Social implications will be shown in a higher gaming revenue. It is very likely – as shown in our research – that employees will receive higher wages as these will be topped up by tips. The state, in turn, will collect more taxes.

  11. Hard-tip, soft-spring lithography.

    Science.gov (United States)

    Shim, Wooyoung; Braunschweig, Adam B; Liao, Xing; Chai, Jinan; Lim, Jong Kuk; Zheng, Gengfeng; Mirkin, Chad A

    2011-01-27

    Nanofabrication strategies are becoming increasingly expensive and equipment-intensive, and consequently less accessible to researchers. As an alternative, scanning probe lithography has become a popular means of preparing nanoscale structures, in part owing to its relatively low cost and high resolution, and a registration accuracy that exceeds most existing technologies. However, increasing the throughput of cantilever-based scanning probe systems while maintaining their resolution and registration advantages has from the outset been a significant challenge. Even with impressive recent advances in cantilever array design, such arrays tend to be highly specialized for a given application, expensive, and often difficult to implement. It is therefore difficult to imagine commercially viable production methods based on scanning probe systems that rely on conventional cantilevers. Here we describe a low-cost and scalable cantilever-free tip-based nanopatterning method that uses an array of hard silicon tips mounted onto an elastomeric backing. This method-which we term hard-tip, soft-spring lithography-overcomes the throughput problems of cantilever-based scanning probe systems and the resolution limits imposed by the use of elastomeric stamps and tips: it is capable of delivering materials or energy to a surface to create arbitrary patterns of features with sub-50-nm resolution over centimetre-scale areas. We argue that hard-tip, soft-spring lithography is a versatile nanolithography strategy that should be widely adopted by academic and industrial researchers for rapid prototyping applications.

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... cystic fibrosis. CF CARE CENTER finder We provide funding for and accredit more than 120 care centers ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  13. Volume reduction technology of radioactive waste and clearance practice of contaminated material

    International Nuclear Information System (INIS)

    Gao Chao

    2016-01-01

    • One of principles of RW management is minimization and reduction: - Advance process and facilities should be reasonably applied to reduce the waste generation (''Law of the People's Republic of China on Prevention and Control of Radioactive Pollution'', 2003); - Operator of RW storage facilities should dispose or clear up solid waste timely (''Regulations on the safety of RW management'', 2011); • Reduction principle: - Control of generation; - Use of volume reduction technique; - Clearance of slightly contaminated material

  14. Numerical Simulation of LVAD Inflow Cannulas with Different Tip

    Directory of Open Access Journals (Sweden)

    Guang-Mao Liu

    2012-01-01

    Full Text Available The tip structure of LVAD inflow cannula is one of major factors to lead adverse events such as thrombosis and suction leading to obstruction. In this research, four kinds of tips that had been used in inflow cannulas were selected and designed. The flow field of the four inflow cannulas inserted into the apex of left ventricle (LV was numerically computed by computational fluid dynamics. The flow behavior was analyzed in order to compare the blood compatibility and suction in left ventricle and cannulas after the inflow cannulas with different tips were inserted to the apex of LV. The results showed that the cannula tip structure affected the LVAD performance. Among these four cannulas, the trumpet-tipped inflow cannula owned the best performance in smooth flow velocity distribution without backflow or low-velocity flow so that it was the best in blood compatibility. Nevertheless, the caged tipped cannula was the worst in blood compatibility. And the blunt-tipped and beveled tipped inflow cannulas may obstruct more easily than trumpet and caged tipped inflow cannulas because of their shape. The study indicated that the trumpet tip was the most preferable for the inflow cannula of long-term LVAD.

  15. 48 CFR 32.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  16. 48 CFR 832.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  17. Secretion clearance strategies in Australian and New Zealand Intensive Care Units.

    Science.gov (United States)

    Ntoumenopoulos, George; Hammond, Naomi; Watts, Nicola R; Thompson, Kelly; Hanlon, Gabrielle; Paratz, Jennifer D; Thomas, Peter

    2017-06-26

    To describe the processes of care for secretion clearance in adult, intubated and mechanically ventilated patients in Australian and New Zealand Intensive Care Units (ICUs). A prospective, cross-sectional study was conducted through the Australian and New Zealand Intensive Care Society Clinical Trials Group (ANZICS CTG) Point Prevalence Program. Forty-seven ICUs collected data from 230 patients intubated and ventilated on the study day. Secretion clearance techniques beyond standard suctioning were used in 84/230 (37%) of patients during the study period. Chest wall vibration 34/84 (40%), manual lung hyperinflation 24/84 (29%), chest wall percussion 20/84 (24%), postural drainage/patient positioning 17/84 (20%) and other techniques including mobilisation 15/84 (18%), were the most common secretion clearance techniques employed. On average (SD), patients received airway suctioning 8.8 (5.0) times during the 24-h study period. Mucus plugging events were infrequent (2.7%). The additional secretion clearance techniques were provided by physiotherapy staff in 24/47 (51%) ICUs and by both nursing and physiotherapy staff in the remaining 23/47 (49%) ICUs. One-third of intubated and ventilated patients received additional secretion clearance techniques. Mucus plugging events were infrequent with these additional secretion clearance approaches. Prospective studies must examine additional secretion clearance practices, prevalence of mucus plugging episodes and impact on patient outcomes. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  18. Association between swallow perception and esophageal bolus clearance in patients with globus sensation.

    Science.gov (United States)

    Chen, Chien-Lin; Yi, Chih-Hsun; Liu, Tso-Tsai

    2013-04-01

    Globus sensation is common, but its pathogenesis is not yet clear. Our purpose was to investigate subjective perception of swallowing and esophageal motility by combined multichannel intraluminal impedance and manometry (MII-EM) for patients with globus sensation. Combined MII-EM was performed for 25 globus patients and 15 healthy controls. Swallows were abnormal if hypocontractivity or simultaneous contractions occurred. Esophageal bolus transit was incomplete if bolus exit was not found at one or more of all measurement sites. Perception of each swallow was assessed by use of a standardized scoring system, and was enhanced if the score was >1. Few globus patients reported enhanced perception during viscous or solid swallows. Incomplete bolus transit and enhanced perception occurred similarly between viscous and solid boluses. Agreement between enhanced perception and proximal bolus clearance was greater during solid swallows (κ = 0.45, 95 % CI: 0.32-0.58) than during viscous swallows (κ = 0.13, 95 % CI: 0-0.25) (P perception and total bolus clearance was greater during solid swallows (κ = 0.46, 95 % CI: 0.34-0.58) than during viscous swallows (κ = 0.11, 95 % CI: 0-0.22) (P perception is uncommon in patients with globus sensation, although there is a significant association between enhanced esophageal perception and solid bolus clearance. Application of a solid bolus may help better delineation of the interrelationship between the subjective perception of bolus passage and the objective measurement of bolus clearance.

  19. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  20. 75 FR 17375 - Submission for OMB Review; Comment Request

    Science.gov (United States)

    2010-04-06

    ... Papers to the Technology Innovation Program (TIP). OMB Control Number: None. Form Number(s): None. Type..., concepts and knowledge offered by stakeholders in these white papers combined with information from a..., Departmental Paperwork Clearance Officer, (202) 482-0266, Department of Commerce, Room 6625, 14th and...

  1. Effect of glucose-insulin-potassium infusion on thallium myocardial clearance

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Factors influencing the rate of 201 Tl clearance from the myocardium have not been clearly defined. This study determined the effect of an intravenous infusion of glucose-insulin-potassium (GIK) on the net 201 Tl clearance rates from myocardium with and without initial 201 Tl loading. Anesthetized open-chest dogs underwent 5 min of left anterior descending coronary artery occlusion and intravenous 201 Tl was injected and the occlusion released 5 min later. Thirty minutes after 201 Tl injection, 30 ml of either GIK (nine dogs) or saline (five dogs) was infused intravenously. The clearance rates of 201 Tl from the anterior wall (without initial 201 Tl loading) and from the posterior wall (with initial 201 Tl loading) were monitored with miniaturized cadmium telluride detectors placed on the myocardium. Calculation of net myocardial clearance rates was performed by linear regression analysis from serial 1 min counts. Compared with saline infusion, GIK increased the net clearance of 201 Tl from both myocardial regions with and without initial loading. The most marked change induced by GIK infusion was in the myocardial region without initial 201 Tl loading; a net increase in 201 Tl activity (72 +/- 42 cpm/30 min) was converted into a net loss (-594 +/- 228 cpm/30 min). There was no significant change in 201 Tl clearance after the saline infusion. Heart rate, aortic and left atrial pressure, sonomicrometer-measured transmural myocardial wall thickness, microsphere-determined myocardial blood flow, and blood glucose and potassium concentrations did not change significantly during GIK or saline infusions. Thus, GIK infusion appears to increase net 201 Tl clearance from myocardial zones with and without initial 201 Tl loading

  2. Productivity tips for developers

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    I like to read about productivity tools and techniques, but the problem is - most of them are completely overrated, the tips are not that useful or they are too difficult to implement. But, sometimes I can find some stuff that really makes me think "damn, how could I live without this before?!". Today, I would like to share some of them and hopefully hear about the tips and tricks that you use. Maybe we can find a way to share them somehow (github repo/forum)?

  3. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  4. Tipping Point

    Medline Plus

    Full Text Available ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit other Web Sites Maintained by CPSC: cpsc.gov| poolsafely.gov| recalls.gov| saferproducts.gov Privacy, Security, and Legal Notice | Accessibility Policy | Open Government @ ...

  5. 48 CFR 1432.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  6. Determining vancomycin clearance in an overweight and obese population.

    Science.gov (United States)

    Leong, Julie V B; Boro, Maureen S; Winter, Michaele

    2011-04-01

    Two methods of calculating vancomycin clearance were compared to determine the best body weight measure to use when dosing vancomycin for overweight and obese patients. Hospitalized veterans weighing more than 120% of their ideal body weight (IBW) with serum vancomycin concentrations (SVCs) drawn between January 1, 2003, and June 30, 2005, were eligible for study inclusion. Exclusion criteria included weight of more than 300% the IBW, unstable renal function, dialysis, uncertain vancomycin dosing or sampling times, and distribution-phase sampling. Data from January 1 through December 31, 2003 (phase 1) determined the best-fit weight for vancomycin clearance for the Leonard and Boro method. The bias and precision of the modified Leonard and Boro method using the best-fit weight for vancomycin clearance were then compared with those of the Rushing and Ambrose method for predicting SVCs from January 1, 2004, through June 30, 2005 (phase 2). Forty-eight patients were included in phase 1, with 67 SVCs for analysis. During phase 1, adjusted body weight (ABW), using the Leonard and Boro method, was superior in predicting vancomycin clearance and the resultant SVCs. A total of 96 patients were included in phase 2 of the study, with 160 SVCs for analysis. The modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting vancomycin clearance. Use of ABW proved to be superior compared with total body weight when estimating vancomycin clearance in overweight and obese patients. While there was no difference in bias between methods, the modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting SVCs when dosing vancomycin for obese patients.

  7. Natural history of progression of HPV infection to cervical lesion or clearance: analysis of the control arm of the large, randomised PATRICIA study.

    Directory of Open Access Journals (Sweden)

    Unnop Jaisamrarn

    Full Text Available The control arm of PATRICIA (PApilloma TRIal against Cancer In young Adults, NCT00122681 was used to investigate the risk of progression from cervical HPV infection to cervical intraepithelial neoplasia (CIN or clearance of infection, and associated determinants.Women aged 15-25 years were enrolled. A 6-month persistent HPV infection (6MPI was defined as detection of the same HPV type at two consecutive evaluations over 6 months and clearance as ≥2 type-specific HPV negative samples taken at two consecutive intervals of approximately 6 months following a positive sample. The primary endpoint was CIN grade 2 or greater (CIN2+ associated with the same HPV type as a 6MPI. Secondary endpoints were CIN1+/CIN3+ associated with the same HPV type as a 6MPI; CIN1+/CIN2+/CIN3+ associated with an infection of any duration; and clearance of infection. The analyses included 4825 women with 16,785 infections (3363 women with 6902 6MPIs. Risk of developing a CIN1+/CIN2+/CIN3+ associated with same HPV type as a 6MPI varied with HPV type and was significantly higher for oncogenic versus non-oncogenic types. Hazard ratios for development of CIN2+ were 10.44 (95% CI: 6.96-15.65, 9.65 (5.97-15.60, 5.68 (3.50-9.21, 5.38 (2.87-10.06 and 3.87 (2.38-6.30 for HPV-16, HPV-33, HPV-31, HPV-45 and HPV-18, respectively. HPV-16 or HPV-33 6MPIs had ~25-fold higher risk for progression to CIN3+. Previous or concomitant HPV infection or CIN1+ associated with a different HPV type increased risk. Of the different oncogenic HPV types, HPV-16 and HPV-31 infections were least likely to clear.Cervical infections with oncogenic HPV types increased the risk of CIN2+ and CIN3+. Previous or concomitant infection or CIN1+ also increased the risk. HPV-16 and HPV-33 have by far the highest risk of progression to CIN3+, and HPV-16 and HPV-31 have the lowest chance of clearance.

  8. Natural history of progression of HPV infection to cervical lesion or clearance: analysis of the control arm of the large, randomised PATRICIA study.

    Science.gov (United States)

    Jaisamrarn, Unnop; Castellsagué, Xavier; Garland, Suzanne M; Naud, Paulo; Palmroth, Johanna; Del Rosario-Raymundo, Maria Rowena; Wheeler, Cosette M; Salmerón, Jorge; Chow, Song-Nan; Apter, Dan; Teixeira, Julio C; Skinner, S Rachel; Hedrick, James; Szarewski, Anne; Romanowski, Barbara; Aoki, Fred Y; Schwarz, Tino F; Poppe, Willy A J; Bosch, F Xavier; de Carvalho, Newton S; Germar, Maria Julieta; Peters, Klaus; Paavonen, Jorma; Bozonnat, Marie-Cecile; Descamps, Dominique; Struyf, Frank; Dubin, Gary O; Rosillon, Dominique; Baril, Laurence

    2013-01-01

    The control arm of PATRICIA (PApilloma TRIal against Cancer In young Adults, NCT00122681) was used to investigate the risk of progression from cervical HPV infection to cervical intraepithelial neoplasia (CIN) or clearance of infection, and associated determinants. Women aged 15-25 years were enrolled. A 6-month persistent HPV infection (6MPI) was defined as detection of the same HPV type at two consecutive evaluations over 6 months and clearance as ≥2 type-specific HPV negative samples taken at two consecutive intervals of approximately 6 months following a positive sample. The primary endpoint was CIN grade 2 or greater (CIN2+) associated with the same HPV type as a 6MPI. Secondary endpoints were CIN1+/CIN3+ associated with the same HPV type as a 6MPI; CIN1+/CIN2+/CIN3+ associated with an infection of any duration; and clearance of infection. The analyses included 4825 women with 16,785 infections (3363 women with 6902 6MPIs). Risk of developing a CIN1+/CIN2+/CIN3+ associated with same HPV type as a 6MPI varied with HPV type and was significantly higher for oncogenic versus non-oncogenic types. Hazard ratios for development of CIN2+ were 10.44 (95% CI: 6.96-15.65), 9.65 (5.97-15.60), 5.68 (3.50-9.21), 5.38 (2.87-10.06) and 3.87 (2.38-6.30) for HPV-16, HPV-33, HPV-31, HPV-45 and HPV-18, respectively. HPV-16 or HPV-33 6MPIs had ~25-fold higher risk for progression to CIN3+. Previous or concomitant HPV infection or CIN1+ associated with a different HPV type increased risk. Of the different oncogenic HPV types, HPV-16 and HPV-31 infections were least likely to clear. Cervical infections with oncogenic HPV types increased the risk of CIN2+ and CIN3+. Previous or concomitant infection or CIN1+ also increased the risk. HPV-16 and HPV-33 have by far the highest risk of progression to CIN3+, and HPV-16 and HPV-31 have the lowest chance of clearance.

  9. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  10. Clearance of Tc-99m DTPA in hemodialysis and peritoneal dialysis: concise communication

    International Nuclear Information System (INIS)

    Wainer, E.; Boner, G.; Lubin, E.; Rosenfeld, J.B.

    1981-01-01

    The clearance of Tc-99m DTPA was studied in 14 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD). Mean Tc-99m DTPA clearance during HD was 37.8% +/- 10.1 of creatinine clearance. Mean Tc-99m DTPA clearance in PD was 65.1% +/- 10.3 of creatinine clearance. Tc-99m DTPA, with a larger molecular weight than that of creatinine, is cleared relatively better during PD than during HD. Thus Tc-99m DTPA may be used in the assessment of the effectiveness of different dialytic treatments for substances of similar molecular weight. In addition, our study shows that clearance of DTPA both in HD and PD is sufficiently high to allow the removal of this chelating agent in patients with renal failure

  11. The role of tip deflection on the thrust produced by rigid flapping fins

    Science.gov (United States)

    Huera-Huarte, Francisco; Gharib, Morteza

    2015-11-01

    It is well known that flexibility plays an important role in the propulsion performance and efficiency of oscillating fin based propulsion systems. Compliance is one of the aspects that has received more attention, as it seems to be a common feature in nature's flyers and swimmers. Active control strategies are also common in nature. We will show how by deflecting only the last 10% of length of a rigid fin, at the tip, the thrust can be changed dramatically. This can be thought as an alternative to passive flexibility for controlling very efficiently the momentum transfer in the wake and therefore the thrust generation when flapping. A series of experiments have been carried with a robotic fin that allowed the control of its flapping kinematics as well as the control of the motions of its tip independently. We will be showing situations in which the tip was kept at a certain fixed position during a power stroke, and others in which it moved either in-phase or out-of-phase with the fin. The observed thrust and wake dynamics will be discussed for all these situations. The authors would like to acknowledge the financial support provided by the Gordon and Betty Moore Foundation and by the Spanish Ministerio de Economia y competitividad (MINECO) through grant DPI2012-37904. Visiting Associate in Aerospace, California Institute of Technology.

  12. Multiple Iterations of Bundle Adjustment for the Position Measurement of Fiber Tips on LAMOST

    Directory of Open Access Journals (Sweden)

    Feng Mingchi

    2014-08-01

    Full Text Available In the astronomical observation process of multi-object fiber spectroscopic telescope, the position measurement of fiber tips on the focal plane is difficult and critical, and is directly related to subsequent observation and ultimate data quality. The fibers should precisely align with the celestial target. Hence, the precise coordinates of the fiber tips are obligatory for tracking the celestial target. The accurate movement trajectories of the fiber tips on the focal surface of the telescope are the critical problem for the control of the fiber positioning mechanism. According to the special structure of the LAMOST telescope and the composition of the initial position error, this paper aims at developing a high precision and robust measurement method based on multiple iterations of bundle adjustment with a few control points. The measurement theory of the proposed methodology has been analyzed, and the measurement accuracy has been evaluated. The experimental results indicate that the new method is more accurate and more reliable than the polynomial fitting method. The maximum position error of the novel measurement algorithm of fiber tips with simulated and real data is 65.3 μm, and most of the position errors conform to the accuracy requirement (40 μm.

  13. TIPS Evaluation Project Retrospective Study: Wave 1 and 2.

    Science.gov (United States)

    Hubbard, Susan M.; Mulvey, Kevin P.

    2003-01-01

    Measured substance abuse treatment professionals' knowledge, attitudes, and practices regarding the Treatment Improvement Protocol (TIP) series and the 28 TIPs. Results for 3,267 respondents in wave 1 and 1,028 in wave 2 indicate that almost half of all professionals were aware of the TIPs. Attitudes toward TIPs were positive, but professionals…

  14. Numerical Investigation on the Effects of Self-Excited Tip Flow Unsteadiness and Blade Row Interactions on the Performance Predictions of Low Speed and Transonic Compressor Rotors

    Science.gov (United States)

    Lee, Daniel H.

    The impact blade row interactions can have on the performance of compressor rotors has been well documented. It is also well known that rotor tip clearance flows can have a large effect on compressor performance and stall margin and recent research has shown that tip leakage flows can exhibit self-excited unsteadiness at near stall conditions. However, the impact of tip leakage flow on the performance and operating range of a compressor rotor, relative to other important flow features such as upstream stator wakes or downstream potential effects, has not been explored. To this end, a numerical investigation has been conducted to determine the effects of self-excited tip flow unsteadiness, upstream stator wakes, and downstream blade row interactions on the performance prediction of low speed and transonic compressor rotors. Calculations included a single blade-row rotor configuration as well as two multi-blade row configurations: one where the rotor was modeled with an upstream stator and a second where the rotor was modeled with a downstream stator. Steady-state and time accurate calculations were performed using a RANS solver and the results were compared with detailed experimental data obtained in the GE Low Speed Research Compressor and the Notre Dame Transonic Rig at several operating conditions including near stall. Differences in the performance predictions between the three configurations were then used to determine the effect of the upstream stator wakes and the downstream blade row interactions. Results obtained show that for both the low speed and transonic research compressors used in this investigation time-accurate RANS analysis is necessary to accurately predict the stalling character of the rotor. Additionally, for the first time it is demonstrated that capturing the unsteady tip flow can have a larger impact on rotor performance predictions than adjacent blade row interactions.

  15. Effect of isolated hepatic ischemia on organic anion clearance and oxidative metabolism.

    Science.gov (United States)

    Minard, G; Bynoe, R; Wood, G C; Fabian, T C; Croce, M; Kudsk, K A

    1992-04-01

    Hepatic failure is frequently seen following severe hemorrhagic shock, sepsis, and trauma. Clearance of various drugs has been used to evaluate hepatocellular dysfunction, including indocyanine green (ICG), an organic anionic dye that is transported similarly to bilirubin, and antipyrine (AP), a marker of oxidative phosphorylation. Previous investigators have noted a decrease in ICG excretion following systemic hemorrhage. The effect of isolated hepatic ischemia on the clearances of ICG and AP was studied in 16 pigs after 90 minutes of vascular occlusion to the liver. Antipyrine clearance decreased almost 50% from baseline values at 24 and 72 hours after the ischemia procedure, indicating a significant depression in the cytochrome P-450 system. On the other hand, ICG clearance did not change significantly. In conclusion, ICG clearance is not depressed after isolated hepatic ischemia in pigs. Changes in organic anion clearance after systemic hemorrhage may be because of release of toxic products from ischemic peripheral tissue.

  16. Management of Bleeding Duodenal Varices with Combined TIPS Decompression and Trans-TIPS Transvenous Obliteration Utilizing 3% Sodium Tetradecyl Sulfate Foam Sclerosis

    Directory of Open Access Journals (Sweden)

    Wael E Saad

    2014-01-01

    Full Text Available Objectives: Endoscopic experience in the management of duodenal varices (DVs is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS or by transvenous obliteration is unresolved. In the literature, the 6-12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. Materials and Methods: This is a retrospective study (case series of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013. TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs and clinical outcomes (rebleeding rate and survival were evaluated. Results: Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days. After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6-50 months

  17. Tip Speed Ratio Based Maximum Power Tracking Control of Variable Speed Wind Turbines; A Comprehensive Design

    Directory of Open Access Journals (Sweden)

    Murat Karabacak

    2017-08-01

    Full Text Available The most primitive control method of wind turbines used to generate electric energy from wind is the fixed speed control method. With this method, it is not possible that turbine input power is transferred to grid at maximum rate. For this reason, Maximum Power Tracking (MPT schemes are proposed. In order to implement MPT, the propeller has to rotate at a different speed for every different wind speed. This situation has led MPT based systems to be called Variable Speed Wind Turbine (VSWT systems. In VSWT systems, turbine input power can be transferred to grid at rates close to maximum power. When MPT based control of VSWT systems is the case, two important processes come into prominence. These are instantaneously determination and tracking of MPT point. In this study, using a Maximum Power Point Tracking (MPPT method based on tip speed ratio, power available in wind is transferred into grid over a back to back converter at maximum rate via a VSWT system with permanent magnet synchronous generator (PMSG. Besides a physical wind turbine simulator is modelled and simulated. Results show that a time varying MPPT point is tracked with a high performance.

  18. Magnetic elements for switching magnetization magnetic force microscopy tips

    International Nuclear Information System (INIS)

    Cambel, V.; Elias, P.; Gregusova, D.; Martaus, J.; Fedor, J.; Karapetrov, G.; Novosad, V.

    2010-01-01

    Using combination of micromagnetic calculations and magnetic force microscopy (MFM) imaging we find optimal parameters for novel magnetic tips suitable for switching magnetization MFM. Switching magnetization MFM is based on two-pass scanning atomic force microscopy with reversed tip magnetization between the scans. Within the technique the sum of the scanned data with reversed tip magnetization depicts local atomic forces, while their difference maps the local magnetic forces. Here we propose the design and calculate the magnetic properties of tips suitable for this scanning probe technique. We find that for best performance the spin-polarized tips must exhibit low magnetic moment, low switching fields, and single-domain state at remanence. The switching field of such tips is calculated and optimum shape of the Permalloy elements for the tips is found. We show excellent correspondence between calculated and experimental results for Py elements.

  19. Thermoelectric voltage at a nanometer-scale heated tip point contact

    Science.gov (United States)

    Fletcher, Patrick C.; Lee, Byeonghee; King, William P.

    2012-01-01

    We report thermoelectric voltage measurements between the platinum-coated tip of a heated atomic force microscope (AFM) cantilever and a gold-coated substrate. The cantilevers have an integrated heater-thermometer element made from doped single crystal silicon, and a platinum tip. The voltage can be measured at the tip, independent from the cantilever heating. We used the thermocouple junction between the platinum tip and the gold substrate to measure thermoelectric voltage during heating. Experiments used either sample-side or tip-side heating, over the temperature range 25-275 °C. The tip-substrate contact is ˜4 nm in diameter and its average measured Seebeck coefficient is 3.4 μV K-1. The thermoelectric voltage is used to determine tip-substrate interface temperature when the substrate is either glass or quartz. When the non-dimensional cantilever heater temperature is 1, the tip-substrate interface temperature is 0.593 on glass and 0.125 on quartz. Thermal contact resistance between the tip and the substrate heavily influences the tip-substrate interface temperature. Measurements agree well with modeling when the tip-substrate interface contact resistance is 108 K W-1.

  20. Ductile crack growth simulation from near crack tip dissipated energy

    International Nuclear Information System (INIS)

    Marie, S.; Chapuliot, S.

    2000-01-01

    A method to calculate ductile tearing in both small scale fracture mechanics specimens and cracked components is presented. This method is based on an estimation of the dissipated energy calculated near the crack tip. Firstly, the method is presented. It is shown that a characteristic parameter G fr can be obtained, relevant to the dissipated energy in the fracture process. The application of the method to the calculation of side grooved crack tip (CT) specimens of different sizes is examined. The value of G fr is identified by comparing the calculated and experimental load line displacement versus crack extension curve for the smallest CT specimen. With this identified value, it is possible to calculate the global behaviour of the largest specimen. The method is then applied to the calculation of a pipe containing a through-wall thickness crack subjected to a bending moment. This pipe is made of the same material as the CT specimens. It is shown that it is possible to simulate the global behaviour of the structure including the prediction of up to 90-mm crack extension. Local terms such as the equivalent stress or the crack tip opening angle are found to be constant during the crack extension process. This supports the view that G fr controls the fields in the vicinity near the crack tip. (orig.)

  1. Lipoprotein lipase activity and chylomicron clearance in rats fed a high fat diet

    International Nuclear Information System (INIS)

    Brown, C.M.; Layman, D.K.

    1988-01-01

    The relationships of tissue and plasma lipoprotein lipase (LPL) activities to tissue uptake and plasma clearance of 14 C-labeled chylomicron-triglyceride ( 14 C-CM-TG) were studied in female rats fed isoenergetic and isonitrogenous control (12% kJ from fat) or high fat diets (72% kJ from fat) for 8 wk. Animals fed the high-fat diet had higher levels of fasting plasma triglycerides and lower LPL activities in heart, renal adipose tissue and post-heparin plasma. Changes in LPL activities of skeletal muscles varied among muscles with higher values in the soleus and plantaris (32-61%) and no differences in the gastrocnemius. The lower LPL activity in renal adipose tissue was associated with lower uptake of fatty acids from 14 C-CM-TG by adipose. Fatty-acid uptake from labeled TG was not associated with tissue LPL activity in other tissues. Clearance of 14 C-CM-TG from plasma and the half-lives of 14 C-CM-TG were similar in both dietary groups. These data indicate that tissue and plasma LPL activities are not a direct index of uptake of fatty acids by tissues or clearance of chylomicron triglycerides

  2. Tapered optical fiber tip probes based on focused ion beam-milled Fabry-Perot microcavities

    Science.gov (United States)

    André, Ricardo M.; Warren-Smith, Stephen C.; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, M. I.; Latifi, H.; Marques, Manuel B.; Bartelt, Hartmut; Frazão, Orlando

    2016-09-01

    Focused ion beam technology is combined with dynamic chemical etching to create microcavities in tapered optical fiber tips, resulting in fiber probes for temperature and refractive index sensing. Dynamic chemical etching uses hydrofluoric acid and a syringe pump to etch standard optical fibers into cone structures called tapered fiber tips where the length, shape, and cone angle can be precisely controlled. On these tips, focused ion beam is used to mill several different types of Fabry-Perot microcavities. Two main cavity types are initially compared and then combined to form a third, complex cavity structure. In the first case, a gap is milled on the tapered fiber tip which allows the external medium to penetrate the light guiding region and thus presents sensitivity to external refractive index changes. In the second, two slots that function as mirrors are milled on the tip creating a silica cavity that is only sensitive to temperature changes. Finally, both cavities are combined on a single tapered fiber tip, resulting in a multi-cavity structure capable of discriminating between temperature and refractive index variations. This dual characterization is performed with the aid of a fast Fourier transform method to separate the contributions of each cavity and thus of temperature and refractive index. Ultimately, a tapered optical fiber tip probe with sub-standard dimensions containing a multi-cavity structure is projected, fabricated, characterized and applied as a sensing element for simultaneous temperature and refractive index discrimination.

  3. Coral Reef Resilience, Tipping Points and the Strength of Herbivory.

    Science.gov (United States)

    Holbrook, Sally J; Schmitt, Russell J; Adam, Thomas C; Brooks, Andrew J

    2016-11-02

    Coral reefs increasingly are undergoing transitions from coral to macroalgal dominance. Although the functional roles of reef herbivores in controlling algae are becoming better understood, identifying possible tipping points in the herbivory-macroalgae relationships has remained a challenge. Assessment of where any coral reef ecosystem lies in relation to the coral-to-macroalgae tipping point is fundamental to understanding resilience properties, forecasting state shifts, and developing effective management practices. We conducted a multi-year field experiment in Moorea, French Polynesia to estimate these properties. While we found a sharp herbivory threshold where macroalgae escape control, ambient levels of herbivory by reef fishes were well above that needed to prevent proliferation of macroalgae. These findings are consistent with previously observed high resilience of the fore reef in Moorea. Our approach can identify vulnerable coral reef systems in urgent need of management action to both forestall shifts to macroalgae and preserve properties essential for resilience.

  4. Effects of plastic anisotropy on crack-tip behaviour

    DEFF Research Database (Denmark)

    Legarth, Brian Nyvang; Tvergaard, Viggo; Kuroda, Mitsutoshi

    2002-01-01

    For a crack in a homogeneous material the effect of plastic anisotropy on crack-tip blunting and on the near-tip stress and strain fields is analyzed numerically. The full finite strain analyses are carried out for plane strain under small scale yielding conditions, with purely symmetric mode I...... loading remote from the crack-tip. In cases where the principal axes of the anisotropy are inclined to the plane of the crack it is found that the plastic zones as well as the stress and strain fields just around the blunted tip of the crack become non-symmetric. In these cases the peak strain...... on the blunted tip occurs off the center line of the crack, thus indicating that the crack may want to grow in a different direction. When the anisotropic axes are parallel to the crack symmetry is retained, but the plastic zones and the near-tip fields still differ from those predicted by standard isotropic...

  5. Embolization with the Amplatzer Vascular Plug in TIPS Patients

    International Nuclear Information System (INIS)

    Pattynama, Peter M. T.; Wils, Alexandra; Linden, Edwin van der; Dijk, Lukas C. van

    2007-01-01

    Vessel embolization can be a valuable adjunct procedure in transjugular intrahepatic portosystemic shunt (TIPS). During the creation of a TIPS, embolization of portal vein collaterals supplying esophageal varices may lower the risk of secondary rebleeding. And after creation of a TIPS, closure of the TIPS itself may be indicated if the resulting hepatic encephalopathy severely impairs mental functioning. The Amplatzer Vascular Plug (AVP; AGA Medical, Golden Valley, MN) is well suited for embolization of large-diameter vessels and has been employed in a variety of vascular lesions including congenital arteriovenous shunts. Here we describe the use of the AVP in the context of TIPS to embolize portal vein collaterals (n = 8) or to occlude the TIPS (n = 2)

  6. A novel tracking tool for the analysis of plant-root tip movements

    International Nuclear Information System (INIS)

    Russino, A; Ascrizzi, A; Popova, L; Tonazzini, A; Mancuso, S; Mazzolai, B

    2013-01-01

    The growth process of roots consists of many activities, such as exploring the soil volume, mining minerals, avoiding obstacles and taking up water to fulfil the plant's primary functions, that are performed differently, depending on environmental conditions. Root movements are strictly related to a root decision strategy, which helps plants to survive under stressful conditions by optimizing energy consumption. In this work, we present a novel image-analysis tool to study the kinematics of the root tip (apex), named analyser for root tip tracks (ARTT). The software implementation combines a segmentation algorithm with additional software imaging filters in order to realize a 2D tip detection. The resulting paths, or tracks, arise from the sampled tip positions through the acquired images during the growth. ARTT allows work with no markers and deals autonomously with new emerging root tips, as well as handling a massive number of data relying on minimum user interaction. Consequently, ARTT can be used for a wide range of applications and for the study of kinematics in different plant species. In particular, the study of the root growth and behaviour could lead to the definition of novel principles for the penetration and/or control paradigms for soil exploration and monitoring tasks. The software capabilities were demonstrated by experimental trials performed with Zea mays and Oryza sativa. (paper)

  7. Gamma-scintigraphy as a novel method to study the distribution and clearance rate of different muco adhesive nasal delivery systems

    International Nuclear Information System (INIS)

    Tofaghodi, M.; Zakavi, R.; Sajadi Tabasi, A.; Jaafari, M.R.

    2002-01-01

    Nasal route has a high potential for drug delivery. One important limiting factor for nasal drug delivery is the rapid clearance of drugs from the nasal cavity. Several nasal drug delivery systems including different kinds of microspheres and liposomes have been tried for encapsulation of drugs and increasing the residence time in nasal cavity. In this study clearance rate of three kinds of microspheres (Alginate, PLGA and Dextran) and four kinds of liposomes (neutral, cationic, fusogenic and cationic-fusogenic) was determined. Lactose powder was used as negative control. Technetium pertechnetate labeling and gamma scintigraphy was used for precise and quantitative measurement of clearance rate of these delivery system. 99 mTc labeled microspheres and liposomes were prepared using technetium pertechnetate in the presence of a potent reducing agent, st annus chloride. The labeling procedure was set in a manner that each 150 micro litter of liposome suspensions and each 3-5 mg of microspheres contained 2 MBq of radioactivity. Labeling efficiency was calculated by paper chromatography using acetone as mobile phase. Each delivery system containing 2 MBq of activity was sprayed into right nostril of four healthy volunteers and immediately after spraying, anterior view of nasal cavity was measured by a large field gamma camera equipped with a low-energy high resolution parallel collimator. One minute static views were repeated each half hour until 4 hours. Clearance rates were compared using two ROI; the initial site of deposition of sprays, and all of nasal cavity to nasopharynx. Clearance rate of each one of microspheres and liposomes was calculated after applying the physical decay corrections. The labeling efficiency for liposomes and microspheres calculated as 41.2% and 60.7% respectively. The cleared percent of delivery systems after 4 hours was determined as follows: neutral liposomes 18.7±3.9% cationic liposomes 43.7±2.1%; fusogenic liposomes 32.8±2

  8. TIPS para o controle das complicações da hipertensão portal: eficácia, fatores prognósticos associados e variações técnicas TIPS for controlling portal hypertension complications: efficacy, predictors of outcome and technical variations

    Directory of Open Access Journals (Sweden)

    Néstor Hugo Kisilevzky

    2006-12-01

    Full Text Available OBJETIVO: Avaliar a eficácia do TIPS (transjugular intrahepatic portosystemic shunt para tratar as complicações clínicas em pacientes com hipertensão portal. MATERIAIS E MÉTODOS: Quarenta e quatro pacientes, sendo 30 do sexo masculino e 14 do feminino e com idade média de 52 anos foram analisados. A indicação para realização de TIPS foi hemorragia gastrintestinal em 28 e ascite refratária em 16. Houve 7 pacientes Child-Pugh A, 24 Child-Pugh B e 11 Child-Pugh C. RESULTADOS: O TIPS foi realizado com sucesso em todos os pacientes (100%, verificando-se queda do gradiente pressórico porto-sistêmico médio de 49,69% (de 18,98 mmHg para 9,55 mmHg. Comprovou-se melhora clínica em 35 pacientes (79,55%. A mortalidade pós-operatóriaia foi de 13,64%, sendo mais incidente nos pacientes Child-Pugh C (45,45%. Os fatores mais relevantes de mau prognóstico foram o aumento da bilirrubina e do nível de creatinina. A sobrevida média de pacientes Child-Pugh A foi de 11,5 meses, nos Child-Pugh B foi de 10,97 meses e nos Child-Pugh C foi de apenas 5,9 meses. Foram observadas complicações em nove casos (20,44%. CONCLUSÃO: O TIPS é eficiente para reduzir a pressão portal. As complicações e a morbi-mortalidade relacionadas com o procedimento podem ser consideradas aceitáveis. A mortalidade foi influenciada por alguns fatores clínicos, tais como classe Child-Pugh C e elevação dos níveis séricos de bilirrubina e creatinina.OBJECTIVE: To evaluate the efficacy of TIPS (transjugular intrahepatic portosystemic shunt for resolving clinical complications in patients with portal hypertension. MATERIALS AND METHODS: Forty-four caucasian patients, 30 men and 14 women, with a mean age of 52 years have been evaluated. Indication for TIPS has been gastrointestinal hemorrhage in 28 patients, and refractory ascites in 16. There has been 7 Child-Pugh A patients, 24 Child-Pugh B, and 11 Child-Pugh C. RESULTS: TIPS was successfully performed in all the

  9. Crack tip stress and strain

    International Nuclear Information System (INIS)

    Francois, D.

    1975-01-01

    The study of potential energy variations in a loaded elastic solid containing a crack leads to determination of the crack driving force G. Generalization of this concept to cases other than linear elasticity leads to definition of the integral J. In a linear solid, the crack tip stress field is characterized by a single parameter: the stress-intensity factor K. When the crack tip plastic zone size is confined to the elastic singularity J=G, it is possible to establish relationship between these parameters and plastic strain (and in particular the crack tip opening displacement delta). The stress increases because of the triaxiality effect. This overload rises with increasing strain hardening. When the plastic zone size expands, using certain hypotheses, delta can be calculated. The plastic strain intensity is exclusively dependent on parameter J [fr

  10. Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.

    Science.gov (United States)

    Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E

    2008-01-01

    Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.

  11. 48 CFR 245.7101-4 - DD Form 1640, Request for Plant Clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false DD Form 1640, Request for Plant Clearance. 245.7101-4 Section 245.7101-4 Federal Acquisition Regulations System DEFENSE... Forms 245.7101-4 DD Form 1640, Request for Plant Clearance. Use to request plant clearance assistance or...

  12. Renal clearance of 99mTc-methylene-diphosphonate in human beings

    International Nuclear Information System (INIS)

    Vattimo, A.

    1987-01-01

    The renal clearance of 99m Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of 51 Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the 99m Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion. (orig.) [de

  13. Exercise increases the lung clearance of inhaled Tc-99m DTPA

    International Nuclear Information System (INIS)

    Meignan, M.; Rosso, J.; Cinotti, L.; Galle, P.

    1985-01-01

    It has been suggested that blood flow have little effect on the lung clearance of Tc-99m DTPA which depends on the alveolar distension. However an increase of pulmonary blood flow, induces a recruitment of new vascular areas which can enhance this clearance. To assess this hypothesis the pulmonary apical and basal clearances of a sumicronic aerosol of Tc-99m DTPA were studied at rest and at exercise in seven non smoking volunteers in upright posture. As a matter of fact exercising upright is known to increase primarily the apical blood flow. After inhalation the subjects were seated on a bicycle their back against a gamma camera which was linked to a computer. The lung radioactivity was registered successively during a resting and an exercising period. At rest there was a gradient of clearance from the apex to the base of the lung, the apical clearance being significantly higher. At exercise (50 Watts, 60 c. min /sup -1/, 7 min.) this regional gradient was enhanced by a large and significant increase of the apical clearances (0.0340 min /sup -1/ +-0.0063 SD versus 0.00183 min /sup -1/ +- 0.074 SD at rest, n = 7, p < 0.01). By contrast the changes of the basal clearances were slight and unsignificant (0.0146 min /sup -1/ +- 0.0062 SD versus 0.0140 min /sup -1/ +- 0.0082 SD). Since exercise induces little distension of the apical alveoli but drastically enhances the apical blood flow, the observed increase of the apical lung clearance could be primarily attributed to the recruitment of new capillaries induced by exercise in the apices. This led to an increase of the surface area permeability product

  14. Oxygen Tension Beneath Scleral Lenses of Different Clearances.

    Science.gov (United States)

    Giasson, Claude J; Morency, Jeanne; Melillo, Marc; Michaud, Langis

    2017-04-01

    To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

  15. Acute exposure to acid fog. Effects on mucociliary clearance

    International Nuclear Information System (INIS)

    Laube, B.L.; Bowes, S.M. III; Links, J.M.; Thomas, K.K.; Frank, R.

    1993-01-01

    Submicrometric sulfuric acid (H2SO4) aerosol can affect mucociliary clearance without eliciting irritative symptoms or changes in pulmonary function. The effect of larger fog droplets containing H2SO4 on mucociliary clearance is unknown. We quantified mucociliary clearance from the trachea (n = 4) and small airways (n = 7) of young healthy male adults after an acute exposure to H2SO4 fog (MMAD = 10.3 microns; pH = 2.0; liquid water content = 481 +/- 65 mg/m3; osmolarity = 30 mOsm). Acid fog (AF) or saline fog (SF) (10.9 microns; 492 +/- 116 mg/m3; 30 mOsm) was administered for 40 min of unencumbered breathing (no mouth-piece) at rest and for 20 min of exercise sufficient to produce oronasal breathing. Fog exposures were followed by a methacholine (MCh) challenge (a measure of airway reactivity) or inhalation of technetium-99M radioaerosol (MMAD = 3.4 microns) on 2 study days each. Changes in symptoms and forced ventilatory function were also assessed. Clearance was quantified from computer-assisted analyses of gamma camera images of the lower respiratory tract in terms of %removal/min of the radiolabel from the trachea 25 min after inhalation and from the outer zone of the right lung after 1.9 to 3 h. Symptoms, forced ventilatory function, and MCh response were unaffected by either fog. Tracheal clearance was more rapid in four of four subjects after AF (0.83 +/- 1.58% removal/min) compared with that after SF (-0.54 +/- 0.85% removal/min). Outer zone clearance was more rapid in six of seven subjects after AF (0.22 +/- 0.15% removal/min) compared with that after SF (0.01 +/- 0.09% removal/min)

  16. 20 CFR 655.150 - Interstate clearance of job order.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  17. Controlling the Outcome of Melting Radioactive Sources in Scrap Metal: from Exclusion, Exemption and Clearance towards a 'Codex Metallarius'

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.J., E-mail: agonzale@sede.arn.gov.ar [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina)

    2011-07-15

    Orphan radiation sources have been inadvertently incorporated into scrap metal and traces of radioactive residues have appeared in finished metal products causing public anxiety, despair in industry and governmental concern. The international principles of exclusion, exemption and clearance can be used to tackle this problem. They are described in detail, as they are becoming universally established for defining the scope of radiation protection regulations. However, notwithstanding the relevance of these principles, the paper suggests a straightforward professional consensus for discontinuing radiological control of commodities with minute traces of radioactive residues. The consensus should unambiguously specify a generic activity concentration in inedible commodities, including metals, below which radiological control may be effectively relinquished. A subsequent legally binding intergovernmental undertaking could resolve the current regulatory ambiguity, facilitate commercial exchange and ensure adequate public protection. For metals, it might take the form of a 'Codex Metallarius' (similar to the existing Codex Alimentarius for edible commodities) establishing a generic level of radiological acceptability for finished metal products. Furthermore, it is proposed that there should be an international convention to prevent radioactive sources becoming orphaned from regulatory control and then inadvertently appearing in trash and scrap. (author)

  18. Dimerization of glycoprotein Ibα is not sufficient to induce platelet clearance.

    Science.gov (United States)

    Liang, X; Syed, A K; Russell, S R; Ware, J; Li, R

    2016-02-01

    ESSENTIALS: Many anti-glycoprotein (GP)Ibα antibodies induce platelet clearance in a dimer-dependent manner. Characterization of monoclonal antibodies that bind the mechanosensitive domain (MSD) of GPIbα. An anti-MSD antibody binds two copies of GPIbα in platelets but does not induce platelet clearance. The prevailing clustering model of GPIbα signaling is incorrect or needs revision. The mechanism of platelet clearance is not clear. Many antibodies binding the membrane-distal ligand-binding domain of glycoprotein (GP)Ibα induce rapid clearance of platelets and acute thrombocytopenia, which requires the bifurcated antibody structure. It was thought that binding of these antibodies induced lateral dimerization or clustering of GPIbα in the plasma membrane, which leads to downstream signaling and platelet clearance. However, many antibodies targeting GPIbβ and GPIX, which are associated with GPIbα in the GPIb-IX complex, do not induce platelet clearance, which is in contradiction to the clustering model. To test whether dimerization or clustering of GPIbα is sufficient to transmit the signal that leads to platelet clearance. We have recently raised several mAbs targeting the mechanosensitive domain (MSD) of GPIbα. Binding of these anti-MSD antibodies was characterized with biochemical methods. Their ability to stimulate platelets and induce platelet clearance in mice was assessed. Infusion of anti-MSD antibodies does not cause thrombocytopenia in mice. These antibodies show no detectable effects on platelet activation and aggregation in vitro. Further biochemical investigation showed that the anti-MSD antibody 3D1 binds two copies of GPIbα on the platelet surface. Therefore, lateral dimerization of GPIbα induced by antibody binding is not sufficient to initiate GPIb-IX signaling and induce platelet clearance. Our results suggest that a factor other than or in addition to clustering of GPIbα is required to induce platelet clearance. © 2015 International

  19. Clearance of technetium-99m-labeled DTPA in hyperthyroidism without clinical evidence of lung disease, and relation to pulmonary function

    International Nuclear Information System (INIS)

    Guldiken, S.; Tugrul, A.; Altiay, G.; Hacimahmutoglu, S.; Durmus-Altun, G.

    2005-01-01

    The mechanisms of dyspnea and exercise intolerance have not been fully elucidated. We aimed to investigate the clearance rate of technetium-99m diethyltriaminepentaaceticacid (Tc-99m DTPA) from lungs in hyperthyroid patients without clinical evidence of lung disease and to explore the interactions between their Tc-99m DTPA radioaerosol lung scintigraphy, spirometric measurements, and the levels of thyroid hormones. We studied 19 hyperthyroid patients and 16 sex- and age-matched controls. Thyroid hormone levels were assessed. Spirometric lung function tests, diffusing capacity of the lung for carbon monoxide (DLCO) and the clearance rate of Tc-99m DTPA were performed in all participants. Ratio of DLCO value to the alveolar ventilation (DLCO/VA) and the means of half-time (T 1/2 ) of Tc-99m DTPA clearance rate, which were used to evaluate alveolar-capillary membrane permeability, were calculated. There were no statistical differences between spirometric parameters (vital capacity (VC), force vital capacity (FVC), one second forced expiratory volume (FEV 1 )/FVC, mean forced expiratory flow during the middle of FVC (FEF 25-75)) of the two groups (p>0.05). Although the mean FEV 1 level was significantly lower in the hyperthyroid patients than the control subjects (p 1 was only less than 80 percent of the predicted value. No significant difference in the means of DLCO, DLCO/VA or T 1/2 values of Tc-99m DTPA clearance was observed between the two groups (p>0.05). In hyperthyroid patients, there was a positive relation between DLCO/VA, DLCO/VA% and T 1/2 values of Tc-99m DTPA clearance (p 1/2 values of Tc-99m DTPA clearance in hyperthyroid group (p>0.05). We conclude that increased thyroid hormones have no effect on permeability of alveolar-capillary membrane in hyperthyroid patients. (author)

  20. Research progress in TIPS shunt dysfunction and recanalization

    Directory of Open Access Journals (Sweden)

    WANG Tingting

    2015-11-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS is widely used in the treatment of cirrhotic portal hypertension and its associated complications. However, postoperative shunt dysfunction has been an important factor restricting the clinical application of TIPS. This article summarizes the use of shunt, the incidence of shunt dysfunction after TIPS, preventive measures and diagnostic methods for shunt dysfunction, and indications and techniques of shunt recanalization, in order to enhance our knowledge of shunt dysfunction and recanalization, which could further improve the efficacy of TIPS for cirrhotic portal hypertension.