WorldWideScience

Sample records for tiniv complexes x-ray

  1. Ion exchange reactions of n-butylamine intercalates of tin(IV) hydrogen phosphate and hydrogen uranyl phosphate with cobalt(III) complexes

    International Nuclear Information System (INIS)

    Pozas-Tormo, R.; Moreno-Real, L.; Martinez-Lara, M.; Rodriguez-Castellon, E.

    1986-01-01

    The ion exchange reactions of n-butylamine intercalates of tin(IV) hydrogen phosphate and hydrogen uranyl phosphate towards carbonatotetraamminecobalt(III), chloropentaamminecobalt(III), and hexamminecobalt(III) have been investigated. Independent of the complex cation charges, the amounts of Co(III) complex exchanged by the n-butylamine intercalate of tin(IV) hydrogen phosphate are practically the same. With the n-butylamine intercalate of hydrogen uranyl phosphate, the ionic exchange was completed and the composition was fixed by the exchanged Co(III) complex. The layer charge densities of these phosphates justify the different ionic exchange behaviour observed towards the large complex cations. All the products were characterized by chemical analysis, X-ray diffractory, infrared spectroscopy, diffuse reflectance spectroscopy, and thermal analysis

  2. Tin(IV Complexes of Schiff Base Derived from Amino Acid: Synthesis and Characteristic Spectral Studies

    Directory of Open Access Journals (Sweden)

    Robina Aman

    2013-01-01

    Full Text Available A new series of tin(IV complexes of general formula [Sn(L-1(Opri2] (1, [Sn(HL-12(Opri2] (2, [Sn(L-2(Opri2] (3, [Sn(HL-22(Opri2] (4, (L is dianion of Schiff bases derived from the condensation of 2-hydroxy-1-naphthaldehyde with glycine (L-1 and Lβ-alanine (L-2 was synthesized by reaction of tin(IV tetraisopropoxide with the ligands, in appropriate stoichiometric ratios (1 : 1 and 1 : 2. This would result in the replacement of the isopropoxide group from the tin(IV tetraisopropoxide and hydrogen(s from ligand with the azeotropical removal of isopropanol. An attempt has been made to prove the structure of the resulting complexes on the basis of elemental analysis, IR, 1H nuclear magnetic resonance. The binding site of the ligand was identified by IR spectroscopic measurement. In these complexes, the tin(IV centre is bonded to oxygen atom of the hydroxyl or carboxylate group. The spectra data suggest that the carboxylate group is coordinated to tin(IV centre in monodentate manner.

  3. Characterizing Complexity of Containerized Cargo X-ray Images

    International Nuclear Information System (INIS)

    Wang, Guangxing; Martz, Harry; Glenn, Steven; Divin, Charles; Birrer, Nat

    2016-01-01

    X-ray imaging can be used to inspect cargos imported into the United States. In order to better understand the performance of X-ray inspection systems, the X-ray characteristics (density, complexity) of cargo need to be quantified. In this project, an image complexity measure called integrated power spectral density (IPSD) was studied using both DNDO engineered cargos and stream-of-commerce (SOC) cargos. A joint distribution of cargo density and complexity was obtained. A support vector machine was used to classify the SOC cargos into four categories to estimate the relative fractions.

  4. Stimulated X-Ray Emission Spectroscopy in Transition Metal Complexes

    Science.gov (United States)

    Kroll, Thomas; Weninger, Clemens; Alonso-Mori, Roberto; Sokaras, Dimosthenis; Zhu, Diling; Mercadier, Laurent; Majety, Vinay P.; Marinelli, Agostino; Lutman, Alberto; Guetg, Marc W.; Decker, Franz-Josef; Boutet, Sébastien; Aquila, Andy; Koglin, Jason; Koralek, Jake; DePonte, Daniel P.; Kern, Jan; Fuller, Franklin D.; Pastor, Ernest; Fransson, Thomas; Zhang, Yu; Yano, Junko; Yachandra, Vittal K.; Rohringer, Nina; Bergmann, Uwe

    2018-03-01

    We report the observation and analysis of the gain curve of amplified K α x-ray emission from solutions of Mn(II) and Mn(VII) complexes using an x-ray free electron laser to create the 1 s core-hole population inversion. We find spectra at amplification levels extending over 4 orders of magnitude until saturation. We observe bandwidths below the Mn 1 s core-hole lifetime broadening in the onset of the stimulated emission. In the exponential amplification regime the resolution corrected spectral width of ˜1.7 eV FWHM is constant over 3 orders of magnitude, pointing to the buildup of transform limited pulses of ˜1 fs duration. Driving the amplification into saturation leads to broadening and a shift of the line. Importantly, the chemical sensitivity of the stimulated x-ray emission to the Mn oxidation state is preserved at power densities of ˜1020 W /cm2 for the incoming x-ray pulses. Differences in signal sensitivity and spectral information compared to conventional (spontaneous) x-ray emission spectroscopy are discussed. Our findings build a baseline for nonlinear x-ray spectroscopy for a wide range of transition metal complexes in inorganic chemistry, catalysis, and materials science.

  5. Phase stabilization in cinnarizine complexes using X-ray profile ...

    Indian Academy of Sciences (India)

    Abstract. Characterization of cobalt(II), cadmium(II), copper(II) and tin(II) cinnarizine complexes have been carried out using conductivity, electronic spectra, infrared, nmr, thermogravimetric and X- ray analyses to establish the nature of phase stabilization in these materials. Also, the intrinsic strain components present in ...

  6. X-ray tomography using the full complex index of refraction

    DEFF Research Database (Denmark)

    Nielsen, Mikkel Schou; Lauridsen, Torsten; Thomsen, M.

    2012-01-01

    We report on x-ray tomography using the full complex index of refraction recorded with a grating-based x-ray phase-contrast setup. Combining simultaneous absorption and phase-contrast information, the distribution of the full complex index of refraction is determined and depicted in a bivariate...

  7. Study of complex waveguide structure using soft X-ray reflectivity technique

    Science.gov (United States)

    Singh, Amol; Modi, Mohammed H.; Dhawan, R.; Jonnard, P.; Le Guen, K.; André, J.-M.

    2017-05-01

    Grazing incidence x-ray reflectivity (GIXRR) technique is commonly used for structural investigation of layered structures. In case of complex x-ray waveguide structure it is difficult to obtain structural parameters using GIXRR technique owing to narrowly spaced Kiessig fringes. We used GIXRR and soft x-ray reflectivity (SXR) technique to study the x-ray waveguide structure composed of 4 layers Al/ZrC/Al/W on a Si substrate. Structural parameters of the stacks, density, thickness and roughness of the layers, are determined through fitting of SXR data. Advantages of SXR over GIXRR for such layered structure are shown.

  8. X-ray diffraction and X-ray K absorption near edge studies of copper (II) complexes with amino acids

    Science.gov (United States)

    Sharma, P. K.; Mishra, Ashutosh; Malviya, Varsha; Kame, Rashmi; Malviya, P. K.

    2017-05-01

    Synthesis of copper (II) complexes [CuL1L2X].nH2O, where n=1, 2,3 (X=Cl,Br,NO3) (L1is 2,2’-bipyridine and L2 is L-tyrosine) by the chemical root method. The XRD data for the samples have been recorded. EXAFS spectra have also been recorded at the K-edge of Cu using the dispersive beam line BL-8 at 2.5 Gev Indus-2 Synchrotron radiation source at RRCAT, Indore, India. XRD and EXAFS data have been analysed using the computer software. X-ray diffraction studies of all complexes indicate their crystalline nature. Lattice parameter, bond length, particle size have been determined from XRD data.

  9. Confirmation of molecular formulas of metallic complexes through X-ray fluorescence quantitative analysis

    International Nuclear Information System (INIS)

    Filgueiras, C.A.L.; Marques, E.V.; Machado, R.M.

    1984-01-01

    X-ray fluorescence spectrophotometry was employed to determined the metal content in a series of five transition element complexes (Mn, Ti, Zn, V). The results confirmed the molecular formulas of these complexes, already proposed on the basis of elemental microanalysis, solution condutimetry and other analytical methods. (C.L.B.) [pt

  10. Synthesis of new nano Schiff base complexes: X-ray crystallography ...

    African Journals Online (AJOL)

    This study presents synthesis and characterization of new nano uranyl Schiff base complexes. Electrochemistry of these complexes showed a quasireversible redox reaction without any successive reactions. Furthermore, X-ray crystallography exhibited that beside the coordination of tetradentate Schiff base, one solvent ...

  11. X-ray and neutron scattering studies of complex confined fluids

    International Nuclear Information System (INIS)

    Sinha, S. K.

    1999-01-01

    We review recent X-ray and neutron scattering studies of the structure and dynamics of confined complex fluids. This includes the study of polymer conformations and binary fluid phase transitions in porous media using Small Angle Neutron scattering, and the use of synchrotrons radiation to study ordering and fluctuation phenomena at solid/liquid and liquid/air interfaces. Ordering of liquids near a solid surface or in confinement will be discussed, and the study, via specular and off-specular X-ray reflectivity, of capillary wave fluctuations on liquid polymer films. Finally, we shall discuss the use of high-brilliance beams from X-ray synchrotrons to study via photon correlation spectroscopy the slow dynamics of soft condensed matter systems

  12. X-ray and neutron scattering studies of complex confined fluids.

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, S. K.

    1999-08-04

    We review recent X-ray and neutron scattering studies of the structure and dynamics of confined complex fluids. This includes the study of polymer conformations and binary fluid phase transitions in porous media using Small Angle Neutron scattering, and the use of synchrotrons radiation to study ordering and fluctuation phenomena at solid/liquid and liquid/air interfaces. Ordering of liquids near a solid surface or in confinement will be discussed, and the study, via specular and off-specular X-ray reflectivity, of capillary wave fluctuations on liquid polymer films. Finally, we shall discuss the use of high-brilliance beams from X-ray synchrotrons to study via photon correlation spectroscopy the slow dynamics of soft condensed matter systems.

  13. Imaging ultrafast excited state pathways in transition metal complexes by X-ray transient absorption and scattering using X-ray free electron laser source

    DEFF Research Database (Denmark)

    Chen, Lin X; Shelby, Megan L; Lestrange, Patrick J

    2016-01-01

    This report will describe our recent studies of transition metal complex structural dynamics on the fs and ps time scales using an X-ray free electron laser source, Linac Coherent Light Source (LCLS). Ultrafast XANES spectra at the Ni K-edge of nickel(ii) tetramesitylporphyrin (NiTMP) were measur...

  14. Hard X-ray bursts and DD microfusion neutrons from complex ...

    Indian Academy of Sciences (India)

    Email: ykur@online.ru; msk@ccr.jussieu.fr. MS received 1 April 2003; accepted 31 July 2003. Abstract. We create the random complex media of high-power density in low-energy nanosecond vacuum discharges. Hard X-ray emission efficiency, generation of energetic ions ( 1 MeV) and neutrons, trapping and releasing of ...

  15. Coordination symmetry determination of some lanthanide complexes by x-ray diffraction

    International Nuclear Information System (INIS)

    Oliveira Paiva Santos, C. de.

    1983-01-01

    The x-ray determination of the crystal and molecular structures of three lanthanide complexes is described. The work is a contribution to the study of the coordination chemistry of lanthanide ions with organic ligands and in particular, it aims to compare the observed point symmetry of the ion environment with spectroscopic predictions. (author)

  16. Automated x-ray television complex for inspecting standard-size dynamic objects

    International Nuclear Information System (INIS)

    Gusev, E.A.; Luk'yanenko, E.A.; Chelnokov, V.B.; Kuleshov, V.K.; Alkhimov, Yu.V.

    1993-01-01

    An automated x-ray television complex based on a matrix gas-discharge converter having a large area (2.1 x 1.0 m) for inspecting standard-size freight and containers and for diagnosing industrial articles is presented. The pulsed operating mode of the complex with a 512K digital television storage makes it possible to inspect dynamic objects with a minimum dose load (20--100 μR). 6 refs., 5 figs

  17. Automated X-ray television complex for testing large dynamic objects

    International Nuclear Information System (INIS)

    Gusev, E.A.; Luk'yanenko, Eh.A.; Chelnokov, V.B.; Kuleshov, V.K.; Alkhimov, Yu.V.

    1992-01-01

    An automated X-ray television complex on the base of matrix gas-dischage large-area (2.1x1.0 m) converter for testing large cargoes and containers, as well as for inductrial article diagnostics is described. The complex pulsed operation with the 512 kbytes television digital memory unit provides for testing dynamic objects under minimal doses (20-100 μR)

  18. GPU-accelerated depth map generation for X-ray simulations of complex CAD geometries

    Science.gov (United States)

    Grandin, Robert J.; Young, Gavin; Holland, Stephen D.; Krishnamurthy, Adarsh

    2018-04-01

    Interactive x-ray simulations of complex computer-aided design (CAD) models can provide valuable insights for better interpretation of the defect signatures such as porosity from x-ray CT images. Generating the depth map along a particular direction for the given CAD geometry is the most compute-intensive step in x-ray simulations. We have developed a GPU-accelerated method for real-time generation of depth maps of complex CAD geometries. We preprocess complex components designed using commercial CAD systems using a custom CAD module and convert them into a fine user-defined surface tessellation. Our CAD module can be used by different simulators as well as handle complex geometries, including those that arise from complex castings and composite structures. We then make use of a parallel algorithm that runs on a graphics processing unit (GPU) to convert the finely-tessellated CAD model to a voxelized representation. The voxelized representation can enable heterogeneous modeling of the volume enclosed by the CAD model by assigning heterogeneous material properties in specific regions. The depth maps are generated from this voxelized representation with the help of a GPU-accelerated ray-casting algorithm. The GPU-accelerated ray-casting method enables interactive (> 60 frames-per-second) generation of the depth maps of complex CAD geometries. This enables arbitrarily rotation and slicing of the CAD model, leading to better interpretation of the x-ray images by the user. In addition, the depth maps can be used to aid directly in CT reconstruction algorithms.

  19. X-ray-enhanced cancer cell migration requires the linker of nucleoskeleton and cytoskeleton complex.

    Science.gov (United States)

    Imaizumi, Hiromasa; Sato, Katsutoshi; Nishihara, Asuka; Minami, Kazumasa; Koizumi, Masahiko; Matsuura, Nariaki; Hieda, Miki

    2018-04-01

    The linker of nucleoskeleton and cytoskeleton (LINC) complex is a multifunctional protein complex that is involved in various processes at the nuclear envelope, including nuclear migration, mechanotransduction, chromatin tethering and DNA damage response. We recently showed that a nuclear envelope protein, Sad1 and UNC84 domain protein 1 (SUN1), a component of the LINC complex, has a critical function in cell migration. Although ionizing radiation activates cell migration and invasion in vivo and in vitro, the underlying molecular mechanism remains unknown. Here, we examined the involvement of the LINC complex in radiation-enhanced cell migration and invasion. A sublethal dose of X-ray radiation promoted human breast cancer MDA-MB-231 cell migration and invasion, whereas carbon ion beam radiation suppressed these processes in a dose-dependent manner. Depletion of SUN1 and SUN2 significantly suppressed X-ray-enhanced cell migration and invasion. Moreover, depletion or overexpression of each SUN1 splicing variant revealed that SUN1_888 containing 888 amino acids of SUN1 but not SUN1_916 was required for X-ray-enhanced migration and invasion. In addition, the results suggested that X-ray irradiation affected the expression level of SUN1 splicing variants and a SUN protein binding partner, nesprins. Taken together, our findings supported that the LINC complex contributed to photon-enhanced cell migration and invasion. © 2018 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  20. X-ray absorption near edge structure (XANES) study of some hydroxamic mixed ligand copper complexes

    International Nuclear Information System (INIS)

    Mishra, A; Parsai, N; Shrivastava, B D; Soni, N

    2012-01-01

    With the advent of modern bright synchrotron radiation sources, X-ray absorption spectra has emerged as a powerful technique for local structure determination, which can be applied to any type of material. The X-ray absorption measurements of four hydroxamic mixed ligand copper complexes have been performed at the recently developed BL-8 Dispersive EXAFS beamline at 2.5 GeV Indus-2 synchrotron at RRCAT, Indore, India. The X-ray absorption near edge structure (XANES) data obtained has been processed using data analysis program Athena. The energies of the K absorption edge, chemical shifts, edge-widths, shifts of the principal absorption maximum in the complexes have been determined. The values of the chemical shift suggest that copper is in oxidation state +2 in all of the complexes. The chemical shift data has been utilized to estimate effective nuclear charge on copper atom. The order of the chemical shifts has been correlated to the relative ionic character of the bonding in these complexes.

  1. X-ray spectroscopy of the photosynthetic oxygen-evolving complex

    Energy Technology Data Exchange (ETDEWEB)

    Sauer, Ken; Yano, Junko; Yachandra, Vittal K

    2007-04-05

    Water oxidation to dioxygen in photosynthesis is catalyzed by a Mn4Ca cluster with O bridging in Photosystem II (PS II) of plants, algae and cyanobacteria. A variety of spectroscopic methods have been applied to analyzing the participation of the complex. X-ray spectroscopy is particularly useful because it is element-specific, and because it can reveal important structural features of the complex with high accuracy and identify the participation of Mn in the redox chemistry. Following a brief history of the application of X-ray spectroscopy to PS II, an overview of newer results will be presented and a description of the present state of our knowledge based on this approach.

  2. Synthesis, X-ray crystallography, spectroscopy, electrochemistry, thermal and kinetic study of uranyl Schiff base complexes

    Czech Academy of Sciences Publication Activity Database

    Asadi, Z.; Golzard, F.; Eigner, Václav; Dušek, Michal

    2013-01-01

    Roč. 66, č. 20 (2013), s. 3629-3646 ISSN 0095-8972 R&D Projects: GA ČR(CZ) GAP204/11/0809 Institutional support: RVO:68378271 Keywords : X-ray crystallography * uranyl Schiff base complex * kinetics of thermal decomposition * cyclic voltammetry * kinetics and mechanism Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.224, year: 2013

  3. X-ray diffraction study of Penicillium Vitale catalase in the complex with aminotriazole

    Energy Technology Data Exchange (ETDEWEB)

    Borovik, A. A.; Grebenko, A. I.; Melik-Adamyan, V. R., E-mail: mawr@ns.crys.ras.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2011-07-15

    The three-dimensional structure of the enzyme catalase from Penicillium vitale in a complex with the inhibitor aminotriazole was solved and refined by protein X-ray crystallography methods. An analysis of the three-dimensional structure of the complex showed that the inhibition of the enzyme occurs as a result of the covalent binding of aminotriazole to the amino-acid residue His64 in the active site of the enzyme. An investigation of the three-dimensional structure of the complex resulted in the amino-acid residues being more precisely identified. The binding sites of saccharide residues and calcium ions in the protein molecule were found.

  4. Transmission X-ray scattering as a probe for complex liquid-surface structures

    Energy Technology Data Exchange (ETDEWEB)

    Fukuto, Masafumi; Yang, Lin; Nykypanchuk, Dmytro; Kuzmenko, Ivan

    2016-01-28

    The need for functional materials calls for increasing complexity in self-assembly systems. As a result, the ability to probe both local structure and heterogeneities, such as phase-coexistence and domain morphologies, has become increasingly important to controlling self-assembly processes, including those at liquid surfaces. The traditional X-ray scattering methods for liquid surfaces, such as specular reflectivity and grazing-incidence diffraction, are not well suited to spatially resolving lateral heterogeneities due to large illuminated footprint. A possible alternative approach is to use scanning transmission X-ray scattering to simultaneously probe local intermolecular structures and heterogeneous domain morphologies on liquid surfaces. To test the feasibility of this approach, transmission small- and wide-angle X-ray scattering (TSAXS/TWAXS) studies of Langmuir films formed on water meniscus against a vertically immersed hydrophilic Si substrate were recently carried out. First-order diffraction rings were observed in TSAXS patterns from a monolayer of hexagonally packed gold nanoparticles and in TWAXS patterns from a monolayer of fluorinated fatty acids, both as a Langmuir monolayer on water meniscus and as a Langmuir–Blodgett monolayer on the substrate. The patterns taken at multiple spots have been analyzed to extract the shape of the meniscus surface and the ordered-monolayer coverage as a function of spot position. These results, together with continual improvement in the brightness and spot size of X-ray beams available at synchrotron facilities, support the possibility of using scanning-probe TSAXS/TWAXS to characterize heterogeneous structures at liquid surfaces.

  5. Determination of metal-ligand stoichiometries for inorganic complexes using total reflection X-ray fluorescence.

    Science.gov (United States)

    Greaves, E D; Bennun, L; Gomez, J; Nemeth, P; Sajo-Bohus, L

    The methods usually used to determine the ratio metal-ligand in inorganic complexes require a set of solutions with different concentrations for both the ligand and metal. We propose a new method using the total reflection X-ray fluorescence technique, in which the ratio between metal and ligand is determined precisely, easily, and quickly. Experimental results provide evidence that for different chemical complexes, the ligand-metal ratio determined by this technique deviates at most from stoichiometric values by 6%. The technique is restricted usually to elements with Z above 14, and its detection limit is on the order of 10(-8) g/g.

  6. Detection of concealed cars in complex cargo X-ray imagery using Deep Learning.

    Science.gov (United States)

    Jaccard, Nicolas; Rogers, Thomas W; Morton, Edward J; Griffin, Lewis D

    2017-01-01

    Non-intrusive inspection systems based on X-ray radiography techniques are routinely used at transport hubs to ensure the conformity of cargo content with the supplied shipping manifest. As trade volumes increase and regulations become more stringent, manual inspection by trained operators is less and less viable due to low throughput. Machine vision techniques can assist operators in their task by automating parts of the inspection workflow. Since cars are routinely involved in trafficking, export fraud, and tax evasion schemes, they represent an attractive target for automated detection and flagging for subsequent inspection by operators. Development and evaluation of a novel method for the automated detection of cars in complex X-ray cargo imagery. X-ray cargo images from a stream-of-commerce dataset were classified using a window-based scheme. The limited number of car images was addressed by using an oversampling scheme. Different Convolutional Neural Network (CNN) architectures were compared with well-established bag of words approaches. In addition, robustness to concealment was evaluated by projection of objects into car images. CNN approaches outperformed all other methods evaluated, achieving 100% car image classification rate for a false positive rate of 1-in-454. Cars that were partially or completely obscured by other goods, a modus operandi frequently adopted by criminals, were correctly detected. We believe that this level of performance suggests that the method is suitable for deployment in the field. It is expected that the generic object detection workflow described can be extended to other object classes given the availability of suitable training data.

  7. X-Ray structure and cytotoxic activity of a picolinate ruthenium(II–arene complex

    Directory of Open Access Journals (Sweden)

    IVANKA IVANOVIĆ

    2011-01-01

    Full Text Available A ruthenium(II–arene complex with picolinic acid, [(η6-p-cymeneRuCl(pico]∙H2O, was prepared by the reaction of [(η6-p-cymeneRuCl2]2 with picolinic acid in a 1:2 molar ratio in 2-propanol. The compound was characterized by elemental analysis, and IR and NMR spectroscopy. X-ray diffraction analysis showed that the molecule adopts a “three-leg piano-stool” geometry, which is common for this type of complexes. The cytotoxic activity of the complex was tested in two human cancer cell lines HeLa (cervix and FemX (melanoma by MTT assay. The IC50 values were at 82.0 and 36.2 µmol dm-3 for HeLa and FemX cells, respectively.

  8. Complexing membrane for uranium detection by total reflection X-ray fluorescence.

    Science.gov (United States)

    Hatzistavros, Vasilios; Koulouridakis, Pavlos; Kallithrakas-Kontost, Nikolaos

    2005-07-01

    Selective membranes containing a few micrograms of various complexing reagents in a polyvinyl chloride (PVC) matrix were produced in order to determine low uranium concentrations in water. The membranes were produced on the surfaces of quartz glasses, and immersed in water solutions containing uranium salts (5 - 50 ng/mL). By the end of the equilibration time, the membranes were left to dry and analyzed based on the total reflection X-ray fluorescence. The effects of the complexing agents and their mass proportions added in the membranes were studied. The combination of the complexing reagents dithizone and thiourea gave the best result. The minimum detection limit was measured to be equal to 0.8 ng/mL.

  9. Selective mercury determination after membrane complexation and total reflection X-ray fluorescence analysis.

    Science.gov (United States)

    Koulouridakis, Pavlos E; Kallithrakas-Kontos, Nikolaos G

    2004-08-01

    A new method for low mercury concentration analysis in drinking waters is presented. Membranes containing a few micrograms of various complexing reagents were produced on the surface of quartz glasses (reflectors). The reflectors were immersed in water solutions containing various concentrations of inorganic mercury salts at low concentrations (1-40 ng/mL). The membranes were left to equilibrate in 5-500 mL of solution for many hours; when the equilibration stage was finished they were cleaned with ultrapure water and left to dry. Analyses were performed by total reflection X-ray fluorescence (TXRF). The effects of various experimental parameters (complexing agent, equilibrium time, sample volume, etc.) as well as the selectivity of the membranes were studied. The complexing reagent dithizone with a PVC-based membrane gave the best results. The limit of quantitation was 0.8 ng/mL.

  10. X-ray diffraction, FTIR, UV-VIS and SEM studies on chromium (III) complexes

    International Nuclear Information System (INIS)

    Mishra, Ashutosh; Dwivedi, Jagrati; Shukla, Kritika

    2015-01-01

    Five Chromium (III) complexes have been prepared using Schiff base ligands which derived from benzoin and five different amino acids (H 2 N-R). Samples were characterized by XRD, FTIR, UV-VIS and SEM method. X-Ray diffraction pattern analyzed that all chromium (III) complexes have hexagonal structure and crystalline, in nature, using Bruker D8 Advance instrument. Using VERTAX 70, FTIR spectroscopy reveals that Samples have (C=N), (C-O), (M-N) and (M-O) bonds in the range of 4000-400cm −1 . UV-VIS spectroscopy give information that samples absorb the visible light which is in the range of 380-780nm. For this, Lambda 960 spectrometer used. SEM is designed for studying of the solid objects, using JEOL JSM 5600 instrument

  11. Bromate determination in water after membrane complexation and total reflection X-ray fluorescence analysis.

    Science.gov (United States)

    Hatzistavros, Vasilios S; Koulouridakis, Pavlos E; Aretaki, Ioanna I; Kallithrakas-Kontos, Nikolaos G

    2007-04-01

    A new method for the determination of trace levels of bromates by selective membrane collection is presented. Various membranes containing a few micrograms of different complexing reagents in a poly(vinyl chloride) matrix were tested. These membranes were produced on the surface of quartz glass (reflectors), and they were immersed in solutions containing bromate and bromide ions. At the first stage the prepared membranes collected both bromate and bromide ions, so different bromide masking agents were put in the analyzed solutions to avoid bromide collection. By the end of the equilibration time, the reflectors were left to dry, and they were analyzed by total reflection X-ray fluorescence (TXRF). The poly(vinyl chloride) with aliquat-336 membrane and o-dianisidin complexing agent gave the best results. The minimum detection limit was equal to 0.9 ng/mL for ultrapure water and 1.0 ng/mL for drinking water.

  12. Anisotropy enhanced X-ray scattering from solvated transition metal complexes

    DEFF Research Database (Denmark)

    Biasin, Elisa; van Driel, Tim B.; Levi, Gianluca

    2018-01-01

    Time-resolved X-ray scattering patterns from photoexcited molecules in solution are in many cases anisotropic at the ultrafast time scales accessible at X-ray free-electron lasers (XFELs). This anisotropy arises from the interaction of a linearly polarized UV-Vis pump laser pulse with the sample...

  13. X-ray Emission Spectroscopy to Study Ligand Valence Orbitals in Mn Coordination Complexes

    Energy Technology Data Exchange (ETDEWEB)

    Smolentsev, Grigory; Soldatov, Alexander V; Messinger, Johannes; Merz, Kathrin; Weyhermuller, Thomas; Bergmann, Uwe; Pushkar, Yulia; Yano, Junko; Yachandra, Vittal K.; Glatzel, Pieter

    2009-03-02

    We discuss a spectroscopic method to determine the character of chemical bonding and for the identification of metal ligands in coordination and bioinorganic chemistry. It is based on the analysis of satellite lines in X-ray emission spectra that arise from transitions between valence orbitals and the metal ion 1s level (valence-to-core XES). The spectra, in connection with calculations based on density functional theory (DFT), provide information that is complementary to other spectroscopic techniques, in particular X-ray absorption (XANES and EXAFS). The spectral shape is sensitive to protonation of ligands and allows ligands, which differ only slightly in atomic number (e.g., C, N, O...), to be distinguished. A theoretical discussion of the main spectral features is presented in terms of molecular orbitals for a series of Mn model systems: [Mn(H2O)6]2+, [Mn(H2O)5OH]+, [Mn(H2O)5NH2]+, and [Mn(H2O)5NH3]2+. An application of the method, with comparison between theory and experiment, is presented for the solvated Mn2+ ion in water and three Mn coordination complexes, namely [LMn(acac)N3]BPh4, [LMn(B2O3Ph2)(ClO4)], and [LMn(acac)N]BPh4, where L represents 1,4,7-trimethyl-1,4,7-triazacyclononane, acac stands for the 2,4-pentanedionate anion, and B2O3Ph2 represents the 1,3-diphenyl-1,3-dibora-2-oxapropane-1,3-diolato dianion.

  14. X-ray studies of interfacial strontium-extractant complexes in a model solvent extraction system.

    Science.gov (United States)

    Bu, Wei; Mihaylov, Miroslav; Amoanu, Daniel; Lin, Binhua; Meron, Mati; Kuzmenko, Ivan; Soderholm, L; Schlossman, Mark L

    2014-10-30

    The interfacial behavior of a model solvent extraction liquid-liquid system, consisting of solutions of dihexadecyl phosphate (DHDP) in dodecane and SrCl2 in water, was studied to determine the structure of the interfacial ion-extractant complex and its variation with pH. Previous experiments on a similar extraction system with ErCl3 demonstrated that the kinetics of the extraction process could be greatly retarded by cooling through an adsorption transition, thus providing a method to immobilize ion-extractant complexes at the interface and further characterize them with X-ray interface-sensitive techniques. Here, we use this same method to study the SrCl2 system. X-ray reflectivity and fluorescence near total reflection measured the molecular-scale interfacial structure above and below the adsorption transition for a range of pH. Below the transition, DHDP molecules form a homogeneous monolayer at the interface with Sr(2+) coverage increasing from zero to saturation (one Sr(2+) per two DHDP) within a narrow range of pH. Experimental values of Sr(2+) interfacial density determined from fluorescence measurements are larger than those from reflectivity measurements. Although both techniques probe Sr(2+) bound to DHDP, only the fluorescence provides adequate sensitivity to Sr(2+) in the diffuse double layer. A Stern equation determines the Sr(2+) binding constant from the reflectivity measurements and the additional Sr(2+) measured in the diffuse double layer is accounted for by Gouy-Chapman theory. Above the transition temperature, a dilute concentration of DHDP-Sr complexes resides at the interface, even for temperatures far above the transition. A comparison is made of the structure of the interfacial ion-extractant complex for this divalent metal ion to recent results on trivalent Er(3+) metal ions, which provides insight into the role of metal ion charge on the structure of interfacial ion-extractant complexes, as well as implications for extraction of these two

  15. X-ray Absorption Spectroscopy Identifies Calcium-Uranyl-Carbonate Complexes at Environmental Concentrations

    International Nuclear Information System (INIS)

    Kelly, Shelly D.; Kemner, Kenneth M.; Brooks, Scott C.

    2007-01-01

    Current research on bioremediation of uranium-contaminated groundwater focuses on supplying indigenous metal-reducing bacteria with the appropriate metabolic requirements to induce microbiological reduction of soluble uranium(VI) to poorly soluble uranium(IV). Recent studies of uranium(VI) bioreduction in the presence of environmentally relevant levels of calcium revealed limited and slowed uranium(VI) reduction and the formation of a Ca-UO2-CO3 complex. However, the stoichiometry of the complex is poorly defined and may be complicated by the presence of a Na-UO2-CO3 complex. Such a complex might exist even at high calcium concentrations, as some UO2-CO3 complexes will still be present. The number of calcium and/or sodium atoms coordinated to a uranyl carbonate complex will determine the net charge of the complex. Such a change in aqueous speciation of uranium(VI) in calcareous groundwater may affect the fate and transport properties of uranium. In this paper, we present the results from X-ray absorption fine structure (XAFS) measurements of a series of solutions containing 50 lM uranium(VI) and 30 mM sodium bicarbonate, with various calcium concentrations of 0-5 mM. Use of the data series reduces the uncertainty in the number of calcium atoms bound to the UO2-CO3 complex to approximately 0.6 and enables spectroscopic identification of the Na-UO2-CO3 complex. At nearly neutral pH values, the numbers of sodium and calcium atoms bound to the uranyl triscarbonate species are found to depend on the calcium concentration, as predicted by speciation calculations

  16. Probing Complex Structural Behaviour in Dynamically Compressed Matter Using Ultrafast X-ray Diffraction

    Science.gov (United States)

    McMahon, Malcolm

    2017-06-01

    Over the last 25 years, the static compression community has found that structural complexity is almost ubiquitous in high-density matter, even in the elemental metals. And modern structure prediction methods have reported that this complexity continues to ultra-high pressures. The prediction that aluminum will adopt an incommensurate host--guest structure at multi-TPa pressures is particularly noteworthy. As such compressions can only be achieved dynamically, two fundamental questions arise. Firstly, are such complex structural forms able to form on the nanosecond timescales of dynamic compression experiments, and, secondly, if they do, how can we determine their structures? We are currently conducting campaigns at both NIF and LCLS to address and answer these questions, using nanosecond and femtosecond x-ray diffraction to detect phase changes, including melting, and determine the detailed structural response to dynamic compression. A particular aim is to obtain structural data on a par with that long available in static compression research. An overview of recent results from these campaigns, and comparisons to previous studies, will be given. This work is supported by EPSRC under Grant No. EP/J017051/1. Use of the LCLS, SLAC National Accelerator Laboratory, is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Contract No. DE-AC02-76SF00515.

  17. Complex UV/X-ray variability of 1H 0707-495

    Science.gov (United States)

    Pawar, P. K.; Dewangan, G. C.; Papadakis, I. E.; Patil, M. K.; Pal, Main; Kembhavi, A. K.

    2017-12-01

    We study the relationship between the UV and X-ray variability of the narrow-line Seyfert 1 galaxy 1H 0707-495. Using a year-long Swift monitoring and four long XMM-Newton observations, we perform cross-correlation analyses of the UV and X-ray light curves, on both long and short time-scales. We also perform time-resolved X-ray spectroscopy on 1-2 ks scale, and study the relationship between the UV emission and the X-ray spectral components - soft X-ray excess and a power law. We find that the UV and X-ray variations anticorrelate on short, and possibly on long time-scales as well. Our results rule out reprocessing as the dominant mechanism for the UV variability, as well as the inward propagating fluctuations in the accretion rate. Absence of a positive correlation between the photon index and the UV flux suggests that the observed UV emission is unlikely to be the seed photons for the thermal Comptonization. We find a strong correlation between the continuum flux and the soft-excess temperature which implies that the soft excess is most likely the reprocessed X-ray emission in the inner accretion disc. Strong X-ray heating of the innermost regions in the disc, due to gravitational light bending, appears to be an important effect in 1H 0707-495, giving rise to a significant fraction of the soft excess as reprocessed thermal emission. We also find indications for a non-static, dynamic X-ray corona, where either the size or height (or both) vary with time.

  18. X-ray crystal structure of a xanthine oxidase complex with the flavonoid inhibitor quercetin.

    Science.gov (United States)

    Cao, Hongnan; Pauff, James M; Hille, Russ

    2014-07-25

    Xanthine oxidase catalyzes the sequential hydroxylation of hypoxanthine to uric acid via xanthine as intermediate. Deposition of crystals of the catalytic product uric acid or its monosodium salt in human joints with accompanying joint inflammation is the major cause of gout. Natural flavonoids are attractive leads for rational design of preventive and therapeutic xanthine oxidase inhibitors due to their beneficial antioxidant, anti-inflammatory, and antiproliferative activities in addition to their micromolar inhibitory activities toward xanthine oxidase. We determined the first complex X-ray structure of mammalian xanthine oxidase with the natural flavonoid inhibitor quercetin at 2.0 Å resolution. The inhibitor adopts a single orientation with its benzopyran moiety sandwiched between Phe 914 and Phe 1009 and ring B pointing toward the solvent channel leading to the molybdenum active center. The favorable steric complementarity of the conjugated three-ring structure of quercetin with the active site and specific hydrogen-bonding interactions of exocyclic hydroxy groups with catalytically relevant residues Arg 880 and Glu 802 correlate well with a previously reported structure-activity relationship of flavonoid inhibitors of xanthine oxidase. The current complex provides a structural basis for the rational design of flavonoid-type inhibitors against xanthine oxidase useful for the treatment of hyperuricemia, gout, and inflammatory disease states.

  19. Synthesis and X-Ray Crystal Structures of Mononuclear Complexes of 1,3-Bis(8-quinolyloxy)propane

    International Nuclear Information System (INIS)

    Al-Mandhary, M.R.; Steel, P.

    2002-01-01

    The preparations and X-ray crystal structures of the first transition metal complexes of 1,3-bis(8-quinolyloxy)propane are described. The ligand acts as a trans-chelating N,N'-bidentate ligand in the three-coordinate silver nitrate complex and four-coordinate copper chloride complex, but as an N,O,O',N'-tetradentate ligand in the octahedral nickel chloride complex. Copyright (2002) CSIRO Australia

  20. Utilization of x-ray diffraction and fluorescence in complex minerals study from Araxa, Minas Gerais State

    International Nuclear Information System (INIS)

    Murta, C.C.; Mendes, M.J.C.; Ferreira, O.L.

    1992-01-01

    Some 60 to 120 samples from Araxa are being daily analyzed by X ray spectrography for Nb, Ce, La, U, Th, Ba, Fe, Pb, Y and Sr. The correspondence between the number of pulses and the content of each element in the sample is done by calibration curves, got from standards. The results of the analysis are weekly sent to Araxa and are promptly used as orientation of the new works. The study of the mineralogical composition of these ores has mainly been done with the help of X ray diffraction, an almost indispensable tool due to the complexity and fineness of this material. At last, the study by X ray, either by spectrography or diffraction, has been useful in directing ore chessing and chemical experiments, having the advantage of prompt responses. (author)

  1. Determination of crystal structures by x-ray diffraction: applications to a lanthanide complex and a natural organic compound

    International Nuclear Information System (INIS)

    Miranda, J.M. de.

    1986-01-01

    The study fir determining crystal structures of the Ho (ReO sub(4)) sub(3) 4 TDTD 3 H sub(2) O complex and the natural organic compound C sub(14) H sub(16) O sub(6) by X-ray diffraction are presented. The experimental equipments are described in details. (M.C.K.)

  2. Complex of structural roentgenometric and optical parameters of chest X-ray picture for automated fluorograms processing

    International Nuclear Information System (INIS)

    Rodzaevskij, S.A.

    1986-01-01

    The formalized description necessary for the development of algorithms for determination of main object boundaries by the roentgenologic picture during computerized photoroentgenograms processing is drawn up on the basis of the complex of structural roentgenometric parameters of the chest X-ray picture

  3. X-ray structure of a blue complex pigment from the blue flowers of Centaurea cyanus

    International Nuclear Information System (INIS)

    Shiono, M.; Matsugaki, N.; Takeda, K.

    2005-01-01

    Full text: The blue pigment of the cornflower, named protocyanin, has long been investigated, but its precise structure has remained unclear. Our recent research demonstrated the components of protocyanin to be anthocyanin (AN), flavone glycoside (FL), Fe 3+ , Mg 2+ and Ca 2+ ions and we succeeded in the reconstruction of protocyanin. In this study, we revealed the X-ray structure of protocyanin. The crystal structure of the reconstructed protocyanin was determined at a resolution of 1.05 A. The refined molecule has pseudo threefold symmetry and four metal ions, Fe 3+ , Mg 2+ and two Ca 2+ , align along the pseudo three-fold axis. The four metals are coordinated to six AN molecules and six FL molecules. The inner Fe 3+ and Mg 2+ ions are each coordinated to three AN molecules respectively, while the outer two Ca 2+ ions are each coordinated to three FL molecules . Both AN and FL molecules are self-associated with each other as AN-AN and FL-FL in pair and this hydrophobic association also exists between AN and FL molecules. Protocyanin is a tetra-metal (Fe 3+ , Mg 2+ , 2Ca 2+ ) nuclear complex of twelve molecules of anthocyanin and flavone glycoside, a new type of supramolecular pigment. (author)

  4. Determination of uranium in complex matrices using radioisotope induced energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Joseph, Daisy

    2015-01-01

    Uranium is the principal fuel for nuclear reactors and the main raw material for nuclear weapons. Uranium is a very heavy metal which can be used as an abundant source of concentrated energy. Uranium occurs in most rocks with concentrations ranging from 2 to 4 parts per million and is as common in the Earth’s crust as tin, tungsten and molybdenum. Uranium occurs in seawater, and can be recovered from the oceans. Uranium also occurs in rock phosphate used as fertilizers. Uranium can be determined in all these sources by Radioisotope Induced Energy Dispersive X-ray Fluorescence (RIEDXRF). In the light of the above facts I want to bring out the potential of RIEDXRF in determining U in many of the applications. In my talk application of RIEDXRF for the determination of U in sea water, in rock phosphates, in resins, and how EXAFS has been used in studying UL3 chemical shifts of U in elemental form and compounds will be presented. The experimental set up consists of an annular radioisotope source whose photon output falls on the sample kept directly opposite the source. X-rays in reflection geometry falls on the Be window of the Liq N 2 cooled X-ray Semiconductor Si(Li) detector of a resolution of 170 eV at 5.9 keV X-ray and U L-X-rays are detected, determined and stored in a PCA for off-line analysis. The methodology developed, the results obtained and the conclusions will be detailed in the presentation and will review all the work carried out by me in NPD, Bhabha Atomic Research Centre for determination of uranium by Radioisotope Induced Energy Dispersive X-ray Fluorescence and related techniques. (author)

  5. Complex assembly, crystallization and preliminary X-ray crystallographic analysis of the human Rod–Zwilch–ZW10 (RZZ) complex

    International Nuclear Information System (INIS)

    Altenfeld, Anika; Wohlgemuth, Sabine; Wehenkel, Annemarie; Vetter, Ingrid R.; Musacchio, Andrea

    2015-01-01

    The 800 kDa complex of the human Rod, Zwilch and ZW10 proteins (the RZZ complex) was reconstituted in insect cells, purified, crystallized and subjected to preliminary X-ray diffraction analysis. The spindle-assembly checkpoint (SAC) monitors kinetochore–microtubule attachment during mitosis. In metazoans, the three-subunit Rod–Zwilch–ZW10 (RZZ) complex is a crucial SAC component that interacts with additional SAC-activating and SAC-silencing components, including the Mad1–Mad2 complex and cytoplasmic dynein. The RZZ complex contains two copies of each subunit and has a predicted molecular mass of ∼800 kDa. Given the low abundance of the RZZ complex in natural sources, its recombinant reconstitution was attempted by co-expression of its subunits in insect cells. The RZZ complex was purified to homogeneity and subjected to systematic crystallization attempts. Initial crystals containing the entire RZZ complex were obtained using the sitting-drop method and were subjected to optimization to improve the diffraction resolution limit. The crystals belonged to space group P3 1 (No. 144) or P3 2 (No. 145), with unit-cell parameters a = b = 215.45, c = 458.7 Å, α = β = 90.0, γ = 120.0°

  6. Complex assembly, crystallization and preliminary X-ray crystallographic analysis of the human Rod–Zwilch–ZW10 (RZZ) complex

    Energy Technology Data Exchange (ETDEWEB)

    Altenfeld, Anika; Wohlgemuth, Sabine [Max Planck Institute of Molecular Physiology, Otto Hahn Strasse 11, 44227 Dortmund (Germany); Wehenkel, Annemarie [Institut Curie, CNRS UMR 3348/INSERM U1005, Bâtiment 110, Centre Universitaire, 91405 Orsay CEDEX (France); Vetter, Ingrid R. [Max Planck Institute of Molecular Physiology, Otto Hahn Strasse 11, 44227 Dortmund (Germany); Musacchio, Andrea, E-mail: andrea.musacchio@mpi-dortmund.mpg.de [Max Planck Institute of Molecular Physiology, Otto Hahn Strasse 11, 44227 Dortmund (Germany); University of Duisburg-Essen, Universitätstrasse 1, 45141 Essen (Germany)

    2015-03-20

    The 800 kDa complex of the human Rod, Zwilch and ZW10 proteins (the RZZ complex) was reconstituted in insect cells, purified, crystallized and subjected to preliminary X-ray diffraction analysis. The spindle-assembly checkpoint (SAC) monitors kinetochore–microtubule attachment during mitosis. In metazoans, the three-subunit Rod–Zwilch–ZW10 (RZZ) complex is a crucial SAC component that interacts with additional SAC-activating and SAC-silencing components, including the Mad1–Mad2 complex and cytoplasmic dynein. The RZZ complex contains two copies of each subunit and has a predicted molecular mass of ∼800 kDa. Given the low abundance of the RZZ complex in natural sources, its recombinant reconstitution was attempted by co-expression of its subunits in insect cells. The RZZ complex was purified to homogeneity and subjected to systematic crystallization attempts. Initial crystals containing the entire RZZ complex were obtained using the sitting-drop method and were subjected to optimization to improve the diffraction resolution limit. The crystals belonged to space group P3{sub 1} (No. 144) or P3{sub 2} (No. 145), with unit-cell parameters a = b = 215.45, c = 458.7 Å, α = β = 90.0, γ = 120.0°.

  7. Hard X-ray bursts and DD microfusion neutrons from complex ...

    Indian Academy of Sciences (India)

    explosive centres, or 'ectons' [4]). These ensembles emitting X-rays are created by an in- tense energy deposition into the cold solid density, very low volume dusty 'target' specially nucleated and collected at interelectrode space (clusters, grains, microparticles of differ- ent size from anode material). The main anomalous ...

  8. Tracking the picosecond deactivation dynamics of a photoexcited iron carbene complex by time-resolved X-ray scattering

    DEFF Research Database (Denmark)

    Leshchev, Denis; Harlang, Tobias C. B.; Fredin, Lisa A.

    2018-01-01

    Recent years have seen the development of new iron-centered N-heterocyclic carbene (NHC) complexes for solar energy applications. Compared to typical ligand systems, the NHC ligands provide Fe complexes with longer-lived metal-to-ligand charge transfer (MLCT) states. This increased lifetime......)pyridine) is a unique complex as it exhibits a short-lived MC state with a lifetime on the scale of a few hundreds of picoseconds. Hence, this complex allows for a detailed investigation, using 100 ps X-ray pulses from a synchrotron, of strong ligand field effects on the intermediate MC state in an NHC complex. Here...

  9. X-ray and vibrational spectroscopy of manganese complexes relevant to the oxygen-evolving complex of photosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Visser, Hendrik [Univ. of California, Berkeley, CA (United States)

    2001-01-01

    Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-ray absorption near-edge spectroscopy (XANES), Mn Kb X-ray emission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only approximately 0.04 eV for ligand-environment changes. This indicates that Mn Kb XES i s more sensitive to the oxidation state and less sensitive to the ligand environment of the Mn atoms than XANES. These complimentary methods provide information about the oxidation state and the ligand environment of Mn atoms in model compounds and biological systems. A versatile spectroelectrochemical apparatus was designed to aid the interpretation of IR spectra of Mn compounds in different oxidation states. The design, based on an attenuated total reflection device, permits the study of a wide spectral range: 16,700 (600 nm) - 225

  10. X-ray crystallography, electrochemistry, spectral and thermal analysis of some tetradentate schiff base complexes and formation constant measurements

    Czech Academy of Sciences Publication Activity Database

    Asadi, Z.; Savarypour, N.; Dušek, Michal; Eigner, Václav

    2017-01-01

    Roč. 47, č. 11 (2017), s. 1501-1508 ISSN 2470-1556 R&D Projects: GA ČR(CZ) GA15-12653S Institutional support: RVO:68378271 Keywords : X-ray crystallography * transition metal Schiff base complexes * thermogravimetry * electrochemistry * formation constant measurements Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.)

  11. Crystallization and preliminary X-ray diffraction analysis of the protease from Southampton norovirus complexed with a Michael acceptor inhibitor

    International Nuclear Information System (INIS)

    Hussey, R. J.; Coates, L.; Gill, R. S.; Wright, J. N.; Sarwar, M.; Coker, S.; Erskine, P. T.; Cooper, J. B.; Wood, S.; Clarke, I. N.; Lambden, P. R.; Broadbridge, R.; Shoolingin-Jordan, P. M.

    2010-01-01

    The crystallization of the recombinant protease from Southampton norovirus is described. Whilst the native crystals were found to diffract only to medium resolution (2.9 Å), cocrystals with a designed covalently bound inhibitor diffracted X-rays to 1.7 Å resolution. Noroviruses are the predominant cause of human epidemic nonbacterial gastroenteritis. Viral replication requires a cysteine protease that cleaves a 200 kDa viral polyprotein into its constituent functional parts. Here, the crystallization of the recombinant protease from the Southampton norovirus is described. Whilst the native crystals were found to diffract only to medium resolution (2.9 Å), cocrystals of an inhibitor complex diffracted X-rays to 1.7 Å resolution. The polypeptide inhibitor (Ac-EFQLQ-propenyl ethyl ester) possesses an amino-acid sequence designed to match the substrate specificity of the enzyme, but was synthesized with a reactive Michael acceptor group at the C-terminal end

  12. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  13. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  14. Three-dimensional imaging of a complex concaved cuboctahedron copper sulfide crystal by x-ray nanotomography

    International Nuclear Information System (INIS)

    Chen Jie; Tian Jinping; Li Wenjie; Tian Yangchao; Wu Chunyan; Yu Shuhong

    2008-01-01

    By combining Fresnel zone-plate based transmission x-ray microscopy with computed tomography, the nanoscale features in materials with complex shapes can be imaged using synchrotron radiation. The tomographic data sets of a complex copper sulfide crystal were acquired in the angle range ±70 deg. at photon energy of 8.0 keV and then were reconstructed by a standard filtered-back-projection algorithm. This experiment shows the quantifiable three-dimensional information of the copper sulfide crystal, which offers a complete understanding of the concaved cuboctahedron structure with 14 faces comprising of six squares and eight triangles

  15. Ultrafast dynamics of two copper bis-phenanthroline complexes measured by x-ray transient absorption spectroscopy

    DEFF Research Database (Denmark)

    Kelley, Matthew S.; Shelby, Megan L.; Mara, Michael W.

    2017-01-01

    Ultrafast structural dynamics of the metal to ligand charge transfer (MLCT) states of two copper bis-phenanthroline complexes were captured by using x-ray transient absorption (XTA) spectroscopy at the Linac Coherent Light Source and further described by theoretical calculations. These complexes......(I)(dpps)2]+ possesses two bulky phenyl-sulfonate groups attached to each phen ligand that force the molecule to adopt a flattened tetrahedral geometry in the ground state. Previously, optical transient absorption (OTA) and synchrotron based XTA experiments with 100 ps time resolution have been employed...

  16. Complexity of depth-dependent soil macroporosity from X-ray CT data

    Science.gov (United States)

    Martín, M. A.; San José Martínez, F.; Caniego, J.; Tuller, M.; Guber, A.; Pachepsky, Y.; García-Gutierrez, C.

    2009-04-01

    It has been reported that the spatial records of soil properties exhibit a behaviour close to the so-called multifractal structures. Advanced visualisation techniques such as X-ray computed tomography (CT) are required to assess and characterise the multifractal behaviour of soil pore space. In this work we develop the multifractal description of soil porosity values as a function of depth with data from binary 2-D images from X-ray CT scans of 20 cm-long soil columns with diameters of 7.5 cm. The series of depth-dependent macroporosity values exhibited a well defined multifractal structure that was represented by the singularity and the Rényi spectra. The long range dependencies of these series was characterised using the Hurst exponent and the multifractal model. We obtained multifractal spectra that were consistent with multinomial multifractal measures where larger concentrations were less diverse but more common than the smaller ones. Models of pore space connectivity should incorporate a multifractal random structure compatible with this multinomial structure and the long range dependences that have being observed.

  17. Intracellular distribution and stability of a luminescent rhenium(I) tricarbonyl tetrazolato complex using epifluorescence microscopy in conjunction with X-ray fluorescence imaging

    International Nuclear Information System (INIS)

    Wedding, Jason L.; Harris, Hugh H.; Bader, Christie A.; Plush, Sally E.; Mak, Rachel

    2016-01-01

    Optical fluorescence microscopy was used in conjunction with X-ray fluorescence microscopy to monitor the stability and intracellular distribution of the luminescent rhenium(I) complex fac-[Re(CO) 3 (phen)L], where phen = 1,10-phenathroline and L = 5-(4-iodophenyl)tetrazolato, in 22Rv1 cells. The rhenium complex showed no signs of ancillary ligand dissociation, a conclusion based on data obtained via X-ray fluorescence imaging aligning iodine and rhenium distributions. A diffuse reticular localisation was detected for the complex, in the nuclear/perinuclear region of cells, by either optical or X-ray fluorescence techniques. Furthermore, X-ray fluorescence also showed that the Re-I complex disrupted the homeostasis of some biologically relevant elements, such as chlorine, potassium and zinc.

  18. Intracellular distribution and stability of a luminescent rhenium(i) tricarbonyl tetrazolato complex using epifluorescence microscopy in conjunction with X-ray fluorescence imaging.

    Science.gov (United States)

    Wedding, J L; Harris, H H; Bader, C A; Plush, S E; Mak, R; Massi, M; Brooks, D A; Lai, B; Vogt, S; Werrett, M V; Simpson, P V; Skelton, B W; Stagni, S

    2017-04-19

    Optical epifluorescence microscopy was used in conjunction with X-ray fluorescence imaging to monitor the stability and intracellular distribution of the luminescent rhenium(i) complex fac-[Re(CO) 3 (phen)L], where phen = 1,10-phenathroline and L = 5-(4-iodophenyl)tetrazolato, in 22Rv1 cells. The rhenium complex showed no signs of ancillary ligand dissociation, a conclusion based on data obtained via X-ray fluorescence imaging aligning iodine and rhenium distributions. A diffuse reticular localisation was detected for the complex in the nuclear/perinuclear region of cells, by either optical or X-ray fluorescence imaging techniques. X-ray fluorescence also showed that the rhenium complex disrupted the homeostasis of some biologically relevant elements, such as chlorine, potassium and zinc.

  19. Electrodynamics of the EUV/x-ray bright point and filamentary flux loop complexes

    International Nuclear Information System (INIS)

    Ip, W.H.

    1988-01-01

    The electrodynamic model of generation of electric currents in the solar atmosphere, by means of twisting of emerging magnetic flux loops, is investigated with emphasis on the small-scaled EUV/X-ray bright points. It is found that the corresponding power input from such conversion of kinetic energy of the turbulent photospheric plasma into magnetic energy could amount to about 25% of the total energy flux of the solar wind and solar radiation. However, if similar filamentary structures containing colder material are formed in abundance, the total energy budget would be correspondingly larger and the resulting mass injection phenomena may be related to the so-called coronal bullets observed in UV. These energetic features suggest that the coronal dynamics and heating could be dictated by plasma structures with angular sizes <0.1 -1. The authors argue that the Solar and Heliospheric Observatory (SOHO) mission will be essential in addressing these issues basic to solar corona and solar wind acceleration

  20. Coordination Nature of 4-Mercaptoaniline to Sn(II Ion: Formation of a One Dimensional Coordination Polymer and Its Decomposition to a Mono Nuclear Sn(IV Complex

    Directory of Open Access Journals (Sweden)

    Eon S. Burkett

    2014-12-01

    Full Text Available The coordination of the bifunctional ligand 4-mercaptoaniline with aqueo us tin(II metal ion was studied. A coordination polymer was synthesized when an aqueous solution of SnCl2 was treated with 4-MA. The crystalline material is stable under atmospheric conditions retaining its oxidation state. However, when submerged in a solution saturated with oxygen, the compound oxidizes to a mononuclear tin(IV complex. Both the compounds were characterized by single crystal X-ray diffraction studies. Although the structure of the tin(IV complex was previously reported, crystal structure of this compound was redetermined.

  1. Synthesis, spectroscopic characterization, X-ray study and in vitro cytotoxicity of 5-hydroxycoumarin derivatives and their copper complexes

    Science.gov (United States)

    Ostrowska, Kinga; Maciejewska, Dorota; Drzewiecka-Antonik, Aleksandra; Klepka, Marcin T.; Wolska, Anna; Dobrzycki, Łukasz; Sztokfisz, Alicja; Czajkowska, Agnieszka; Młynarczuk-Biały, Izabela

    2017-10-01

    We have synthesized a series of bromo derivatives of 5-hydroxycoumarin and two new Cu(II) complexes with 6-acetyl-8-bromo-5-hydroxy-4,7-dimethylcoumarin (L2) and 6-acetyl-3,8-dibromo-5-hydroxy-4,7-dimethylcoumarin (L3) ligands, designed as potential active compounds against human cancer cell lines. The elemental analysis, mass spectroscopy, NMR and infrared spectroscopy have been used for basic characterization of analyzed compounds. The X-ray crystal structure analysis for one representative organic compound, 3,6,8-tribromo-5-hydroxy-4,7-dimethylcoumarin (c) has been performed. It has shown that coumarin system is nearly planar and the Br⋯Br interaction is a very characteristic feature of the molecular association for organic ligands. The complexes, Cu(L2)2·3H2O and Cu(L3)(ClO4)·2.5H2O, have been found as four-coordinated and contain copper in the +2 oxidation state according to X-ray absorption spectroscopy. All the compounds have been screened in vitro for their cytotoxic activity against mouse fibroblast and human prostate cancer cells. The coordination products of brominated ligands have shown to be more active than the free ligands and demonstrate significant in-vitro cytotoxicity against human prostate cancer cells (DU145).

  2. Local electronic and geometrical structures of hydrogen-bonded complexes studied by soft X-ray spectroscopy

    International Nuclear Information System (INIS)

    Luo, Y.

    2004-01-01

    Full text: The hydrogen bond is one of the most important forms of intermolecular interactions. It occurs in all-important components of life. However, the electronic structures of hydrogen-bonded complexes in liquid phases have long been difficult to determine due to the lack of proper experimental techniques. In this talk, a recent joint theoretical and experimental effort to understand hydrogen bonding in liquid water and alcohol/water mixtures using synchrotron radiation based soft-X-ray spectroscopy will be presented. The complexity of the liquid systems has made it impossible to interpret the spectra with physical intuition alone. Theoretical simulations have thus played an essential role in understanding the spectra and providing valuable insights on the local geometrical and electronic structures of these liquids. Our study sheds light on a 40-year controversy over what kinds of molecular structures are formed in pure liquid methanol. It also suggests an explanation for the well-known puzzle of why alcohol and water do not mix completely: the system must balance nature's tendency toward greater disorder (entropy) with the molecules' tendency to form hydrogen bonds. The observation of electron sharing and broken hydrogen bonding local structures in liquid water will be presented. The possible use of X-ray spectroscopy to determinate the local arrangements of hydrogen-bonded nanostructures will also been discussed

  3. Crystallization and preliminary X-ray structural studies of a Melan-A pMHC–TCR complex

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Fang [Nuffield Department of Clinical Medicine, John Radcliffe Hospital, Oxford University, Oxford OX3 9DU (United Kingdom); Georgiou, Theonie; Hillon, Theresa [STFC Daresbury Laboratory, Warrington, Cheshire WA4 4AD (United Kingdom); Gostick, Emma; Price, David A. [Nuffield Department of Clinical Medicine, John Radcliffe Hospital, Oxford University, Oxford OX3 9DU (United Kingdom); Sewell, Andrew K. [Medical Biochemistry and Immunology, Cardiff University School of Medicine, Cardiff CF14 4XN,Wales (United Kingdom); Moysey, Ruth; Gavarret, Jessie; Vuidepot, Annelise; Sami, Malkit [Medigene, 57c Milton Park, Abingdon, Oxdfordshire OX14 4RX (United Kingdom); Bell, John I. [Nuffield Department of Clinical Medicine, John Radcliffe Hospital, Oxford University, Oxford OX3 9DU (United Kingdom); Gao, George F. [Center for Molecular Immunology, Institute of Microbiology, Chinese Academy of Sciences, 13 Beiyitiao, Zhongguancun, Beijing 100080 (China); Rizkallah, Pierre J., E-mail: p.j.rizkallah@dl.ac.uk [STFC Daresbury Laboratory, Warrington, Cheshire WA4 4AD (United Kingdom); Jakobsen, Bent K., E-mail: p.j.rizkallah@dl.ac.uk [Medigene, 57c Milton Park, Abingdon, Oxdfordshire OX14 4RX (United Kingdom); Nuffield Department of Clinical Medicine, John Radcliffe Hospital, Oxford University, Oxford OX3 9DU (United Kingdom)

    2007-09-01

    A preliminary X-ray crystal structural study of a soluble cognate T-cell receptor (TCR) in complex with a pMHC presenting the Melan-A peptide (ELAGIGILTV) is reported. The TCR and pMHC were refolded, purified and mixed together to form complexes, which were crystallized using the sitting-drop vapour-diffusion method. Single TCR–pMHC complex crystals were cryocooled and used for data collection. Melanocytes are specialized pigmented cells that are found in all healthy skin tissue. In certain individuals, diseased melanocytes can form malignant tumours, melanomas, which cause the majority of skin-cancer-related deaths. The melanoma-associated antigenic peptides are presented on cell surfaces via the class I major histocompatibility complex (MHC). Among the melanoma-associated antigens, the melanoma self-antigen A/melanoma antigen recognized by T cells (Melan-A/MART-1) has attracted attention because of its wide expression in primary and metastatic melanomas. Here, a preliminary X-ray crystal structural study of a soluble cognate T-cell receptor (TCR) in complex with a pMHC presenting the Melan-A peptide (ELAGIGILTV) is reported. The TCR and pMHC were refolded, purified and mixed together to form complexes, which were crystallized using the sitting-drop vapour-diffusion method. Single TCR–pMHC complex crystals were cryocooled and used for data collection. Diffraction data showed that these crystals belonged to space group P4{sub 1}/P4{sub 3}, with unit-cell parameters a = b = 120.4, c = 81.6 Å. A complete data set was collected to 3.1 Å and the structure is currently being analysed.

  4. Crystallization and preliminary X-ray structural studies of a Melan-A pMHC–TCR complex

    International Nuclear Information System (INIS)

    Yuan, Fang; Georgiou, Theonie; Hillon, Theresa; Gostick, Emma; Price, David A.; Sewell, Andrew K.; Moysey, Ruth; Gavarret, Jessie; Vuidepot, Annelise; Sami, Malkit; Bell, John I.; Gao, George F.; Rizkallah, Pierre J.; Jakobsen, Bent K.

    2007-01-01

    A preliminary X-ray crystal structural study of a soluble cognate T-cell receptor (TCR) in complex with a pMHC presenting the Melan-A peptide (ELAGIGILTV) is reported. The TCR and pMHC were refolded, purified and mixed together to form complexes, which were crystallized using the sitting-drop vapour-diffusion method. Single TCR–pMHC complex crystals were cryocooled and used for data collection. Melanocytes are specialized pigmented cells that are found in all healthy skin tissue. In certain individuals, diseased melanocytes can form malignant tumours, melanomas, which cause the majority of skin-cancer-related deaths. The melanoma-associated antigenic peptides are presented on cell surfaces via the class I major histocompatibility complex (MHC). Among the melanoma-associated antigens, the melanoma self-antigen A/melanoma antigen recognized by T cells (Melan-A/MART-1) has attracted attention because of its wide expression in primary and metastatic melanomas. Here, a preliminary X-ray crystal structural study of a soluble cognate T-cell receptor (TCR) in complex with a pMHC presenting the Melan-A peptide (ELAGIGILTV) is reported. The TCR and pMHC were refolded, purified and mixed together to form complexes, which were crystallized using the sitting-drop vapour-diffusion method. Single TCR–pMHC complex crystals were cryocooled and used for data collection. Diffraction data showed that these crystals belonged to space group P4 1 /P4 3 , with unit-cell parameters a = b = 120.4, c = 81.6 Å. A complete data set was collected to 3.1 Å and the structure is currently being analysed

  5. Cluster analysis in soft X-ray spectromicroscopy: finding the patterns in complex specimens

    International Nuclear Information System (INIS)

    Lerotic, M.; Jacobsen, C.

    2004-01-01

    Full text: Soft x-ray spectromicroscopy provides spectral data on the chemical speciation of light elements at sub-100 nanometer spatial resolution. When all chemical species in a specimen are known and separately characterized, existing approaches can be used to measure the concentration of each component at each pixel. In other situations such as in biology or environmental science, this approach may not be possible. A method to find natural groupings of data without prior knowledge of the spectra of all components will be presented. Principal component analysis is used to orthogonalize spectromicroscopy data, and discard much of the noise present in data set. Then cluster analysis is used to find a hierarchical classification of pixels with similar spectra, to extract representative, cluster-averaged spectra with good signal-to-noise ratio, and to obtain gradations of concentration of these representative spectra at each pixel. The method is illustrated with a simulated data set of organic compounds, and a mixture of lutetium in hematite used to understand colloidal transport properties of radionuclides. We gratefully acknowledge funding from the National Institutes for Health under contract R01 EB00479-01A1, and from the National Science Foundation under contracts OCE-0221029 and CHE-0221934

  6. Extended X-ray absorption fine structure of copper(II) complexes at the air-water interface by a polarized total-reflection X-ray absorption technique.

    Science.gov (United States)

    Nagatani, Hirohisa; Tanida, Hajime; Watanabe, Iwao; Sagara, Takamasa

    2009-04-01

    Copper(II) complexes spread on an aqueous solution surface were studied by a polarized total-reflection X-ray absorption fine structure (TR-XAFS) technique. The polarized TR-XAFS spectra at the Cu-K edge for copper(II) porphyrins and copper(II) chlorophyllin in a monolayer were measured in situ at the air-water interface. The polarization dependences of X-ray absorption near-edge structure (XANES) involving a 1s-->4p(z) transition allowed us to estimate the molecular orientation and the local coordination structure around the copper(II) atom in the polarization plane selectively. The extended X-ray absorption fine structure (EXAFS) region of the polarized TR-XAFS spectra for the metal complexes present at the air-water interface was successfully analyzed for the first time. The relative coordination number for the copper center evaluated from the EXAFS analysis indicated larger values in the vertical polarization than in the horizontal one, in agreement with the standing-up molecular orientation at the air-water interface estimated from the XANES region.

  7. Application of X-ray digital radiography to online automated inspection of interior assembly structures of complex products

    Energy Technology Data Exchange (ETDEWEB)

    Han Yueping [National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan 030051 (China) and Key Laboratory of Instrumentation Science and Dynamic Measurement (North University of China), Ministry of Education, Taiyuan 030051 (China)], E-mail: yuepinghan@163.com; Han Yan [Key Laboratory of Instrumentation Science and Dynamic Measurement (North University of China), Ministry of Education, Taiyuan 030051 (China); Li Ruihong [National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan 030051 (China); Wang Liming [Key Laboratory of Instrumentation Science and Dynamic Measurement (North University of China), Ministry of Education, Taiyuan 030051 (China)

    2009-06-11

    The paper proposes an application of X-ray digital radiography to online automated inspection and recognition of the interior assembly structures of complex products by means of the multiple views techniques. First, a vertical hybrid projection function (VHPF) is proposed as the recognition feature of a two-dimensional image. VHPF combines an integral projection function and a standard deviation function so that it can reflect the mean and the variance of the pixels in the vertical direction in an image. Secondly, by considering the different importance grades of objects inside the product and the independence of these objects along the circumference, the paper presents a hierarchical recognition method and uses a neural network system to speed up the computation process with parallel operations. Thirdly, using the whole-orientation features of one standard swatch and by extracting its maximal system of linear independence as the feature basis, the issue of blind areas for recognition is resolved. Based on this approach, the first domestic X-ray multi-view digital detection system has been developed and applied to the online detection of objects containing complicated assembly structures.

  8. Application of X-ray digital radiography to online automated inspection of interior assembly structures of complex products

    International Nuclear Information System (INIS)

    Han Yueping; Han Yan; Li Ruihong; Wang Liming

    2009-01-01

    The paper proposes an application of X-ray digital radiography to online automated inspection and recognition of the interior assembly structures of complex products by means of the multiple views techniques. First, a vertical hybrid projection function (VHPF) is proposed as the recognition feature of a two-dimensional image. VHPF combines an integral projection function and a standard deviation function so that it can reflect the mean and the variance of the pixels in the vertical direction in an image. Secondly, by considering the different importance grades of objects inside the product and the independence of these objects along the circumference, the paper presents a hierarchical recognition method and uses a neural network system to speed up the computation process with parallel operations. Thirdly, using the whole-orientation features of one standard swatch and by extracting its maximal system of linear independence as the feature basis, the issue of blind areas for recognition is resolved. Based on this approach, the first domestic X-ray multi-view digital detection system has been developed and applied to the online detection of objects containing complicated assembly structures.

  9. Application of X-ray digital radiography to online automated inspection of interior assembly structures of complex products

    Science.gov (United States)

    Han, Yueping; Han, Yan; Li, Ruihong; Wang, Liming

    2009-06-01

    The paper proposes an application of X-ray digital radiography to online automated inspection and recognition of the interior assembly structures of complex products by means of the multiple views techniques. First, a vertical hybrid projection function (VHPF) is proposed as the recognition feature of a two-dimensional image. VHPF combines an integral projection function and a standard deviation function so that it can reflect the mean and the variance of the pixels in the vertical direction in an image. Secondly, by considering the different importance grades of objects inside the product and the independence of these objects along the circumference, the paper presents a hierarchical recognition method and uses a neural network system to speed up the computation process with parallel operations. Thirdly, using the whole-orientation features of one standard swatch and by extracting its maximal system of linear independence as the feature basis, the issue of blind areas for recognition is resolved. Based on this approach, the first domestic X-ray multi-view digital detection system has been developed and applied to the online detection of objects containing complicated assembly structures.

  10. Structure investigation, spectral, thermal, X-ray and mass characterization of piroxicam and its metal complexes

    Science.gov (United States)

    Zayed, M. A.; Nour El-Dien, F. A.; Mohamed, Gehad G.; El-Gamel, Nadia E. A.

    2004-10-01

    [M(H 2L) 2](A) 2. yH 2O (where H 2L: neutral piroxicam (Pir), A: Cl - in case of Ni(II) or acetate anion in case of Cu(II) and Zn(II) ions and y=0-2.5) and [M(H 2L) 3](A) z. yH 2O (A: SO 42- in case of Fe(II) ion ( z=1) or Cl - in case of Fe(III) ( z=3) and Co(II) ions ( z=2) and y=1-4) chelates are prepared and characterized using elemental analyses, IR, magnetic and electronic reflectance measurements, mass spectra and thermal analyses. IR spectra reveal that Pir behaves a neutral bidentate ligand coordinated to the metal ions through the pyridyl-N and carbonyl-O of the amide moiety. The reflectance and magnetic moment measurements reveal that these chelates have tetrahedral, square planar and octahedral geometrical structures. Mass spectra and thermal analyses are also used to confirm the proposed formulae and the possible fragments resulted from fragmentation of Pir and its chelates. The thermal behaviour of the chelates (TGA and DTA) are discussed in detail and the thermal stability of the anhydrous chelates follow the order Ni(II)≅Cu(II)X-ray powder diffraction was also used as a confirmatory tool to elucidate the crystallinity of the chelates.

  11. Cosmic x ray physics

    Science.gov (United States)

    Mccammon, Dan; Cox, D. P.; Kraushaar, W. L.; Sanders, W. T.

    1991-01-01

    The annual progress report on Cosmic X Ray Physics for the period 1 Jan. to 31 Dec. 1990 is presented. Topics studied include: soft x ray background, new sounding rocket payload: x ray calorimeter, and theoretical studies.

  12. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  13. Chest x-ray

    Science.gov (United States)

    Chest radiography; Serial chest x-ray; X-ray - chest ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  14. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  15. Introduction to crystal structure determination methods using x-ray diffraction: application to some rare earth complexes

    International Nuclear Information System (INIS)

    Oliveira, M.A. de.

    1986-01-01

    This work is composed by a theoretical introduction studying crystal concept, interaction between X-ray and crystal medium, and methods for determining small molecular structures applied in solution of crystal structures of praseodymium, neodymium and europium complexes with perrhenate and trans - 1,4 - dithiane - 1,4 - dioxide, (TDTD), which general formula is [ Ln (H sub(2) O) sub(4) (η-TDTD) (η'Re O sub(4)) (μ-η sup(2)-TDTD)] sub(n) (Re O sub(4)) sub(2n). nTDTD, where, Ln = Eu, Pr, Nd and methyl-2,6-anhydrous-3-azido-4-0-benzoyl-3-deoxy-α-D-iodo pyranoside. The structure of C sub(14) H sub(15) N sub(3) O sub(5) organic complex was determined using direct methods. (M.C.K.)

  16. The NMR and X-ray study of L-arginine derived Schiff bases and its cadmium complexes

    Science.gov (United States)

    Kołodziej, B.; Grech, E.; Schilf, W.; Kamieński, B.; Pazio, A.; Woźniak, K.

    2014-04-01

    The structure study of five Schiff bases derived from L-arginine (L-Arg) and 2-hydroxy carbonyl compounds were performed in both solution and solid state using NMR and X-ray methods. Both analytical methods applied to the solid state sample of two Schiff bases showed a significant difference in molecular structures of unsubstituted and 7-CH3 substituted compounds. This effect was explained as a steric interaction of methyl group. Additionally the structure of two Cd2+ complexes with some Schiff bases were determined by NMR methods in DMSO solution and in the solid state. On the base of heteronuclear NMR measurement (13C, 15N and 113Cd) it was possible to define the complexation site on nitrogen atom. The large set of spectral parameters: chemical shifts, homo- and heteronuclear coupling constants, were used in structure study.

  17. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  18. X-ray diffraction

    International Nuclear Information System (INIS)

    Einstein, J.R.; Wei, C.H.

    1982-01-01

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  19. Synthesis and characterization of tin(IV) antimonate and study of its ion-exchange equilibria

    International Nuclear Information System (INIS)

    Burham, N.; Abdel-Halim, S.H.; El-Shahat, M.F.

    1995-01-01

    Tin(IV) antimonate with different Sb/Sn molar ratios has been prepared. The characterization of the product materials was carried out using X-ray diffraction pattern, thermal analysis and infrared spectra. The saturation capacities of sodium and cesium were found to increase with Sb/Sn molar ratios. The K d values on thermal treatment of tin(IV) antimonate, as a cation exchanger, have been measured for some heavy metal ions in the temperature range of 50-400 deg C. The maximum adsorption of 10 -4 M of the metal ions studied was obtained at 400 deg C. The selectivity sequence was Eu 3+ > Co 2+ > Sr 2+ > Cs + for the sample heated up to 400 deg C. No adsorption was observed on the sample heated at 700 deg C because of the formation of SnO 2 and Sb 6 O 13 . (author) 9 refs.; 7 figs.; 5 tabs

  20. Study of dinuclear Rh(II) complexes of phenylalanine derivatives as potential anticancer agents by using X-ray fluorescence and X-ray absorption

    NARCIS (Netherlands)

    Majer, Zsuzsa; Bosze, Szilvia; Szabo, Ildiko; Mihucz, Victor G.; Gaal, Aniko; Szilvagyi, Gabor; Pepponi, Giancarlo; Meirer, Florian; Wobrauschek, Peter; Szoboszlai, Norbert; Ingerle, Dieter; Streli, Christina

    In vitro antitumor efficacy of several dinuclear bridgings and one chelate structure dirhodium(II) complex of N-protected phenylalanine derivatives were tested on HT-29 cells. The following synthesized and previously characterized complexes were applied in the present work: Rh-2(OAc)(4)(O-Phe-Z)(n)

  1. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  2. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  3. An X-Ray Photoelectron Spectroscopy (XPS) Study of Activated Carbons Impregnated with some Organocopper Complexes,

    Science.gov (United States)

    1993-10-01

    transition metal complexes containing metals such as copper, chromium and silver, and a ligand such as triethylenediamine were studied. The premise...Cu(hfac).(1,5-COD) 1,5-COD = 1,5-cyclooctadiene (v) Cu(dmg)2 dmg = dimethylglyoxime The synthetic routes to these complexes have been described (1...ORGANOCOPPER COMPLEXES (U) DTIC I ELECTE by JUL 9 1q94 S.H.C. Liang TWOs documofli has bespondtor public 1812CS cu sale i e 94 -23405 ... m-NUE RESEARCH

  4. A pyrrolo-tetrathiafulvalene belt and its TCNQ complex: Syntheses and X-ray crystal structures

    DEFF Research Database (Denmark)

    Nielsen, Kent; Jeppesen, Jan O.; Thorup, Niels

    2002-01-01

    A general and efficient four-step synthesis of a tetrathiafulvalene-belt 6, starting from the monopyrrolo-tetrathiafulvalene building block 1, is described, together with its 7,7,8,8-tetracyano-p-quinodimethane charge transfer complex. The complexation of the electron acceptor 7,7,8,8-tetracyano......-p-quinodimethane by the tetrathlafulvalene-belt 6 was investigated both in solution and in the solid state....

  5. Synthesis, X-ray structure, spectroscopic properties and DFT studies of some dithiocarbazate complexes of nickel(II)

    Science.gov (United States)

    Takjoo, Reza; Centore, Roberto

    2013-01-01

    Two nickel(II) complexes with formulae NiL2 (1) and NiL'Im (2) (HL = allyl 2-benzylidene-hydrazinecarbodithioate, H2L' = allyl 2-(2-hydroxybenzylidene)hydrazinecarbodithioate, Im = Imidazole) have been synthesized and characterized by elemental analysis, molar conductivities, FT-IR, 1H NMR and UV/Vis spectroscopy. The crystal structure of the complexes has been determined by single crystal X-ray diffractometry. Both L and L' ligands are coordinated to the metal in the thiolate form. In 1, the square planar coordination of the metal is achieved by coordination of two bidentate ligand units acting through azomethine nitrogen and the thiolato sulfur donor atoms. The complex 2 has a square-planar geometry with the tridentate ligand coordinated to the metal through salicylate oxygen, azomethine nitrogen and the thiolato sulfur atoms, while the fourth coordination position is occupied by one N atom of imidazole. Also natural bond orbitals (NBOs), frontier molecular orbitals (FMOs) and Mulliken charge computational studies on complexes carried out in the ground state with the DFT and theory at B3LYP/6-31G(d,p) level of theory.

  6. Complex assembly, crystallization and preliminary X-ray crystallographic studies of duck MHC class I molecule

    International Nuclear Information System (INIS)

    Zhang, Jianhua; Chen, Yong; Gao, Feng; Chen, Weihong; Qi, Jianxun; Xia, Chun

    2009-01-01

    Using a peptide derived from H5N1, a complex of duck MHC class I molecule (DuMHC I) with duck β 2 -microglobulin (Duβ 2 m) was assembled and crystallized. Initial structure analysis indicated that the crystals did not contain the complete DuMHC I complex but instead contained DuMHC I α3-domain and Duβ 2 m subunits. In order to understand the biological properties of the immune systems of waterfowl and to establish a system for structural studies of duck class I major histocompatibility complex (DuMHC I), a complex of DuMHC I with duck β 2 -microglobulin (Duβ 2 m) and the peptide AEIEDLIF (AF8) derived from H5N1 NP residues 251–258 was assembled. The complex was crystallized; the crystals belonged to space group C222 1 , with unit-cell parameters a = 54.7, b = 72.4, c = 102.2 Å, and diffracted to 2.3 Å resolution. Matthews coefficient calculation and initial structure determination by molecular replacement showed that the crystals did not contain the whole DuMHC I complex, but instead contained the DuMHC I α3 domain and a Duβ2m molecule (DuMHC I α3+β2m). Another complex of DuMHC I with the peptide IDWFDGKE derived from a chicken fusion protein also generated the same results. The stable structure of DuMHC I α3+β2m may reflect some unique characteristics of DuMHC I and pave the way for novel MHC structure-related studies in the future

  7. The O2-Evolving Complex of Photosystem II: Recent Insights from Quantum Mechanics/Molecular Mechanics (QM/MM), Extended X-ray Absorption Fine Structure (EXAFS), and Femtosecond X-ray Crystallography Data.

    Science.gov (United States)

    Askerka, Mikhail; Brudvig, Gary W; Batista, Victor S

    2017-01-17

    Efficient photoelectrochemical water oxidation may open a way to produce energy from renewable solar power. In biology, generation of fuel due to water oxidation happens efficiently on an immense scale during the light reactions of photosynthesis. To oxidize water, photosynthetic organisms have evolved a highly conserved protein complex, Photosystem II. Within that complex, water oxidation happens at the CaMn 4 O 5 inorganic catalytic cluster, the so-called oxygen-evolving complex (OEC), which cycles through storage "S" states as it accumulates oxidizing equivalents and produces molecular oxygen. In recent years, there has been significant progress in understanding the OEC as it evolves through the catalytic cycle. Studies have combined conventional and femtosecond X-ray crystallography with extended X-ray absorption fine structure (EXAFS) and quantum mechanics/molecular mechanics (QM/MM) methods and have addressed changes in protonation states of μ-oxo bridges and the coordination of substrate water through the analysis of ammonia binding as a chemical analog of water. These advances are thought to be critical to understanding the catalytic cycle since protonation states regulate the relative stability of different redox states and the geometry of the OEC. Therefore, establishing the mechanism for substrate water binding and the nature of protonation/redox state transitions in the OEC is essential for understanding the catalytic cycle of O 2 evolution. The structure of the dark-stable S 1 state has been a target for X-ray crystallography for the past 15 years. However, traditional X-ray crystallography has been hampered by radiation-induced reduction of the OEC. Very recently, a revolutionary X-ray free electron laser (XFEL) technique was applied to PSII to reveal atomic positions at 1.95 Å without radiation damage, which brought us closer than ever to establishing the ultimate structure of the OEC in the S 1 state. However, the atom positions in this crystal

  8. Soft x-ray absorption spectroscopy of metalloproteins and high-valent metal-complexes at room temperature using free-electron lasers

    Directory of Open Access Journals (Sweden)

    Markus Kubin

    2017-09-01

    Full Text Available X-ray absorption spectroscopy at the L-edge of 3d transition metals provides unique information on the local metal charge and spin states by directly probing 3d-derived molecular orbitals through 2p-3d transitions. However, this soft x-ray technique has been rarely used at synchrotron facilities for mechanistic studies of metalloenzymes due to the difficulties of x-ray-induced sample damage and strong background signals from light elements that can dominate the low metal signal. Here, we combine femtosecond soft x-ray pulses from a free-electron laser with a novel x-ray fluorescence-yield spectrometer to overcome these difficulties. We present L-edge absorption spectra of inorganic high-valent Mn complexes (Mn ∼ 6–15 mmol/l with no visible effects of radiation damage. We also present the first L-edge absorption spectra of the oxygen evolving complex (Mn4CaO5 in Photosystem II (Mn < 1 mmol/l at room temperature, measured under similar conditions. Our approach opens new ways to study metalloenzymes under functional conditions.

  9. An X-Ray Photoelectron Spectroscopy (XPS) Study of Activated Carbons Impregnated with Some Organocopper Complexes

    Science.gov (United States)

    1993-10-01

    organocuivre ont dte imprdgn~s & la surface du charbon activd, et la composition de la surface du charbon imprdgn6 a dt examinee par spectroscopie...F/Cu et du C/Cu a pu fitre calcule. Ii a dtd trouvd que trois de ces * complexes dtaient soit instables ou ddcomposds & la surface du charbon . Cette

  10. High-resolution X-ray structure of the trimeric Scar/WAVE-complex precursor Brk1.

    Directory of Open Access Journals (Sweden)

    Joern Linkner

    Full Text Available The Scar/WAVE-complex links upstream Rho-GTPase signaling to the activation of the conserved Arp2/3-complex. Scar/WAVE-induced and Arp2/3-complex-mediated actin nucleation is crucial for actin assembly in protruding lamellipodia to drive cell migration. The heteropentameric Scar/WAVE-complex is composed of Scar/WAVE, Abi, Nap, Pir and a small polypeptide Brk1/HSPC300, and recent work suggested that free Brk1 serves as a homooligomeric precursor in the assembly of this complex. Here we characterized the Brk1 trimer from Dictyostelium by analytical ultracentrifugation and gelfiltration. We show for the first time its dissociation at concentrations in the nanomolar range as well as an exchange of subunits within different DdBrk1 containing complexes. Moreover, we determined the three-dimensional structure of DdBrk1 at 1.5 Å resolution by X-ray crystallography. Three chains of DdBrk1 are associated with each other forming a parallel triple coiled-coil bundle. Notably, this structure is highly similar to the heterotrimeric α-helical bundle of HSPC300/WAVE1/Abi2 within the human Scar/WAVE-complex. This finding, together with the fact that Brk1 is collectively sandwiched by the remaining subunits and also constitutes the main subunit connecting the triple-coil domain of the HSPC300/WAVE1/Abi2/ heterotrimer to Sra1(Pir1, implies a critical function of this subunit in the assembly process of the entire Scar/WAVE-complex.

  11. Structural studies of P-type ATPase–ligand complexes using an X-ray free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Bublitz, Maike; Nass, Karol; Drachmann, Nikolaj D.; Markvardsen, Anders J.; Gutmann, Matthias J.; Barends, Thomas R. M.; Mattle, Daniel; Shoeman, Robert L.; Doak, R. Bruce; Boutet, Sébastien; Messerschmidt, Marc; Seibert, Marvin M.; Williams, Garth J.; Foucar, Lutz; Reinhard, Linda; Sitsel, Oleg; Gregersen, Jonas L.; Clausen, Johannes D.; Boesen, Thomas; Gotfryd, Kamil; Wang, Kai-Tuo; Olesen, Claus; Møller, Jesper V.; Nissen, Poul; Schlichting, Ilme

    2015-06-11

    Membrane proteins are key players in biological systems, mediating signalling events and the specific transport ofe.g.ions and metabolites. Consequently, membrane proteins are targeted by a large number of currently approved drugs. Understanding their functions and molecular mechanisms is greatly dependent on structural information, not least on complexes with functionally or medically important ligands. Structure determination, however, is hampered by the difficulty of obtaining well diffracting, macroscopic crystals. Here, the feasibility of X-ray free-electron-laser-based serial femtosecond crystallography (SFX) for the structure determination of membrane protein–ligand complexes using microcrystals of various native-source and recombinant P-type ATPase complexes is demonstrated. The data reveal the binding sites of a variety of ligands, including lipids and inhibitors such as the hallmark P-type ATPase inhibitor orthovanadate. By analyzing the resolution dependence of ligand densities and overall model qualities, SFX data quality metrics as well as suitable refinement procedures are discussed. Even at relatively low resolution and multiplicity, the identification of ligands can be demonstrated. This makes SFX a useful tool for ligand screening and thus for unravelling the molecular mechanisms of biologically active proteins.

  12. Structural studies of P-type ATPase–ligand complexes using an X-ray free-electron laser

    Directory of Open Access Journals (Sweden)

    Maike Bublitz

    2015-07-01

    Full Text Available Membrane proteins are key players in biological systems, mediating signalling events and the specific transport of e.g. ions and metabolites. Consequently, membrane proteins are targeted by a large number of currently approved drugs. Understanding their functions and molecular mechanisms is greatly dependent on structural information, not least on complexes with functionally or medically important ligands. Structure determination, however, is hampered by the difficulty of obtaining well diffracting, macroscopic crystals. Here, the feasibility of X-ray free-electron-laser-based serial femtosecond crystallography (SFX for the structure determination of membrane protein–ligand complexes using microcrystals of various native-source and recombinant P-type ATPase complexes is demonstrated. The data reveal the binding sites of a variety of ligands, including lipids and inhibitors such as the hallmark P-type ATPase inhibitor orthovanadate. By analyzing the resolution dependence of ligand densities and overall model qualities, SFX data quality metrics as well as suitable refinement procedures are discussed. Even at relatively low resolution and multiplicity, the identification of ligands can be demonstrated. This makes SFX a useful tool for ligand screening and thus for unravelling the molecular mechanisms of biologically active proteins.

  13. The interaction of platinum complexes with low doses of X-rays in hypoxic cells

    International Nuclear Information System (INIS)

    Skov, K.A.

    1992-01-01

    It is not clear why electron affinic compounds (O2, nitroimidazoles) should be more effective sensitizers at high doses (modify double events, 6, 16) while platinum complexes interact to a greater extent at low doses (modification of single-events). The possibility that crosslinks are involved requires further consideration. While DNA intrastrand crosslinks do not appear essential, future low dose experiments are planned to determine the role of interstrand and DNA-protein crosslinks in modifying response at clinical doses. (author). 31 refs., 2 tabs

  14. Determination of the element-specific complex permittivity using a soft x-ray phase modulator

    Science.gov (United States)

    Kubota, Y.; Hirata, Y.; Miyawaki, J.; Yamamoto, S.; Akai, H.; Hobara, R.; Yamamoto, Sh.; Yamamoto, K.; Someya, T.; Takubo, K.; Yokoyama, Y.; Araki, M.; Taguchi, M.; Harada, Y.; Wadati, H.; Tsunoda, M.; Kinjo, R.; Kagamihata, A.; Seike, T.; Takeuchi, M.; Tanaka, T.; Shin, S.; Matsuda, I.

    2017-12-01

    We report on directly determining the complex permittivity tensor using a method combining a developed light source from a segmented cross undulator of synchrotron radiation and the magneto-optical Kerr effect. The empirical permittivity, which carries the electronic and magnetic information of a material, has element specificity and has perfect confirmation using the quantum-mechanical calculation for itinerant electrons systems. These results help in understanding the interaction of light and matter, and they provide an interesting approach to seek the best materials as optical elements, for example, in extended-ultraviolet lithographic technologies or in state-of-the-art laser technologies.

  15. X-ray structure of the mammalian GIRK2-βγ G-protein complex

    Energy Technology Data Exchange (ETDEWEB)

    Whorton, Matthew R.; MacKinnon, Roderick [Rockefeller

    2013-07-30

    G-protein-gated inward rectifier K+ (GIRK) channels allow neurotransmitters, through G-protein-coupled receptor stimulation, to control cellular electrical excitability. In cardiac and neuronal cells this control regulates heart rate and neural circuit activity, respectively. Here we present the 3.5Å resolution crystal structure of the mammalian GIRK2 channel in complex with βγ G-protein subunits, the central signalling complex that links G-protein-coupled receptor stimulation to K+ channel activity. Short-range atomic and long-range electrostatic interactions stabilize four βγ G-protein subunits at the interfaces between four K+ channel subunits, inducing a pre-open state of the channel. The pre-open state exhibits a conformation that is intermediate between the closed conformation and the open conformation of the constitutively active mutant. The resultant structural picture is compatible with ‘membrane delimited’ activation of GIRK channels by G proteins and the characteristic burst kinetics of channel gating. The structures also permit a conceptual understanding of how the signalling lipid phosphatidylinositol-4,5-bisphosphate (PIP2) and intracellular Na+ ions participate in multi-ligand regulation of GIRK channels.

  16. Structural insights into the mycobacteria transcription initiation complex from analysis of X-ray crystal structures

    Energy Technology Data Exchange (ETDEWEB)

    Hubin, Elizabeth A.; Lilic, Mirjana; Darst, Seth A.; Campbell, Elizabeth A.

    2017-07-13

    The mycobacteria RNA polymerase (RNAP) is a target for antimicrobials against tuberculosis, motivating structure/function studies. Here we report a 3.2 Å-resolution crystal structure of a Mycobacterium smegmatis (Msm) open promoter complex (RPo), along with structural analysis of the Msm RPo and a previously reported 2.76 Å-resolution crystal structure of an Msm transcription initiation complex with a promoter DNA fragment. We observe the interaction of the Msm RNAP α-subunit C-terminal domain (αCTD) with DNA, and we provide evidence that the αCTD may play a role in Mtb transcription regulation. Our results reveal the structure of an Actinobacteria-unique insert of the RNAP β' subunit. Finally, our analysis reveals the disposition of the N-terminal segment of Msm σA, which may comprise an intrinsically disordered protein domain unique to mycobacteria. The clade-specific features of the mycobacteria RNAP provide clues to the profound instability of mycobacteria RPo compared with E. coli.

  17. Estimation of doses to patients from ''complex'' conventional X-ray examinations

    International Nuclear Information System (INIS)

    Calzado, A.; Vano, E.; Moran, P.; Ruiz, S.; Gonzalez, L.; Castellote, C.

    1991-01-01

    A numerical method has been developed to estimate organ doses and effective dose-equivalent for patients undergoing three 'complex' examinations (barium meal, barium enema and intravenous urography). The separation of radiological procedures into a set of standard numerical views is based on the use of Monte Carlo conversion factors and measurements within a Remab phantom. Radiation doses measured in a phantom for such examinations were compared with predictions of the ''numerical'' method. Dosimetric measurements with thermoluminescent dosemeters attached to the patient's skin along with measurements of the dose-area product during the examination have enabled the derivation of organ doses and to estimate effective dose-equivalent. Mean frequency weighted values of dose-area product, energy imparted to the patient, doses to a set of organs and effective dose-equivalent in the area of Madrid are reported. Comparisons of results with those from similar surveys in other countries were made. (author)

  18. EFFECT OF POLYPHENOLIC COMPLEX FROM WINE ON RATS ANTIOXIDANT ENZYMES ACTIVITY AT X-RAY IRRADIATION LOW DOSES

    Directory of Open Access Journals (Sweden)

    U. V. Datsyuk

    2014-04-01

    Full Text Available It is shown that the consumption of natural polyphenolic complex from grape wine in drinking water in the daily dose 2.5 ± 1.1 mg polyphenols/kg body mass of rats during the 10 day before exposure to radiation leads to increased of superoxide dismutase and gluthathione reductase activities in peripheral blood on 24 and 48 hours after full body X-ray irradiation (30 cGy. The of catalase, gluthathione peroxidase activities and the of the reactive thiobarbituric acid substances content in total lysates of peripheral blood within 72 hours after exposure are comparable to those in control rats. Marked decreased of catalase and superoxide dismutase activities at 24, 48 and 24 hours, respectively, was observed after exposure to ionizing radiation and increased content of lipid peroxidation products in all above mentioned time points. The decreased of superoxide dismutase and gluthathione peroxidase activities in lysates of rats aorta at 48 hour and increased content of the reactive thiobarbituric acid substances during 72 hours after radiation exposure were observed. The consumption of polyphenolic complex from wine did not change the superoxide dismutase and catalase activities in lysates of aorta rats treated with ionizing radiation, whereas gluthathione reductase and gluthathione peroxidase activities was increased during 72 hours after radiation influence. The content of TBA reactive substances was significantly decreased in lysates of aorta rats that were exposed to radiation and polyphenols of grape wine, compared with those of animals that were exposed to radiation alone.

  19. Overexpression, purification, crystallization and preliminary X-ray analysis of uracil N-glycosylase from Mycobacterium tuberculosis in complex with a proteinaceous inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Prem [Molecular Biophysics Unit, Indian Institute of Science, Bangalore 560 012 (India); Talawar, Ramappa K.; Krishna, P. D. V.; Varshney, Umesh [Department of Microbiology and Cell Biology, Indian Institute of Science, Bangalore 560 012 (India); Vijayan, M., E-mail: mv@mbu.iisc.ernet.in [Molecular Biophysics Unit, Indian Institute of Science, Bangalore 560 012 (India)

    2006-12-01

    Uracil N-glycosylase from M. tuberculosis has been crystallized in complex with a proteinaceous inhibitor (Ugi) and X-ray diffraction data have been collected. Uracil N-glycosylase is an enzyme which initiates the pathway of uracil-excision repair of DNA. The enzyme from Mycobacterium tuberculosis was co-expressed with a proteinaceous inhibitor from Bacillus subtilis phage and was crystallized in monoclinic space group C2, with unit-cell parameters a = 201.14, b = 64.27, c = 203.68 Å, β = 109.7°. X-ray data from the crystal have been collected for structure analysis.

  20. Overexpression, purification, crystallization and preliminary X-ray analysis of uracil N-glycosylase from Mycobacterium tuberculosis in complex with a proteinaceous inhibitor

    International Nuclear Information System (INIS)

    Singh, Prem; Talawar, Ramappa K.; Krishna, P. D. V.; Varshney, Umesh; Vijayan, M.

    2006-01-01

    Uracil N-glycosylase from M. tuberculosis has been crystallized in complex with a proteinaceous inhibitor (Ugi) and X-ray diffraction data have been collected. Uracil N-glycosylase is an enzyme which initiates the pathway of uracil-excision repair of DNA. The enzyme from Mycobacterium tuberculosis was co-expressed with a proteinaceous inhibitor from Bacillus subtilis phage and was crystallized in monoclinic space group C2, with unit-cell parameters a = 201.14, b = 64.27, c = 203.68 Å, β = 109.7°. X-ray data from the crystal have been collected for structure analysis

  1. Rietveld texture analysis of complex oxides: examples of polyphased Bi2223 superconducting and Co349 thermoelectric textured ceramics characterization using neutron and X-ray diffraction

    International Nuclear Information System (INIS)

    Guilmeau, E.; Chateigner, D.; Noudem, J.; Funahashi, R.; Horii, S.

    2005-01-01

    Orientation distributions of cobaltite thermoelectric and polyphased bismuth-based cuprate superconducting textured materials are determined from neutron and X-ray diffraction analysis. Curved position-sensitive detectors coupled to a tilt-angle (χ) scan enable the treatment of the whole diffraction pattern using the combined Rietveld-WIMV-Popa algorithm. The textures of three phases of superconducting compounds are determined. The critical current densities, measured for four samples, are strongly dependent on the calculated texture strengths, crystallite sizes and phase ratios. For the cobaltite compounds, a comparison between X-ray and neutron analysis shows the advantages of the latter technique for avoiding the limitations of the X-ray analysis with respect to the defocusing effect. The results highlight the necessity and efficiency of the combined approach for a quantitative texture analysis of complex materials and exemplify the texture-anisotropic physical properties relationship for a better understanding and design of improved bulk superconducting and thermoelectric materials

  2. An investigation of the chromium oxidation state of a monoanionic chromium tris(catecholate) complex by X-ray absorption and EPR spectroscopies

    DEFF Research Database (Denmark)

    Pattison, D I; Levina, A; Davies, Michael Jonathan

    2001-01-01

    The well-known monoanionic Cr tris(3,5-di-tert-butylcatecholato) complex, [Cr(DTBC)3]-, has been studied by X-ray absorption spectroscopy. The multiple-scattering fit to the XAFS gave good correlation (R = 19.8%) and good values for all of the bond lengths, angles, and Debye-Waller factors. The p...

  3. Zinc(II) complexes with potent cyclin-dependent kinase inhibitors derived from 6-benzylaminopurine: synthesis, characterization, X-ray structures and biological activity

    Czech Academy of Sciences Publication Activity Database

    Trávníček, Zdeněk; Kryštof, Vladimír; Šipl, M.

    2006-01-01

    Roč. 100, č. 2 (2006), s. 214-225 ISSN 0162-0134 R&D Projects: GA ČR GA203/04/1168 Institutional research plan: CEZ:AV0Z50380511 Keywords : Zinc(II) complexes * 6-Benzylaminopurine derivatives * Bohemine * Olomoucine * X-ray structures Subject RIV: CA - Inorganic Chemistry Impact factor: 2.654, year: 2006

  4. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  5. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  6. Dental x-rays

    Science.gov (United States)

    X-ray - teeth; Radiograph - dental; Bitewings; Periapical film; Panoramic film; Digital image ... dentist's office. There are many types of dental x-rays. Some of them are: Bitewing. Shows the crown ...

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  8. X-ray (image)

    Science.gov (United States)

    X-rays are a form of ionizing radiation that can penetrate the body to form an image on ... will be shades of gray depending on density. X-rays can provide information about obstructions, tumors, and other ...

  9. Effects of X-Ray Radiation on Complex Visual Discrimination Learning and Social Recognition Memory in Rats

    Science.gov (United States)

    Davis, Catherine M.; Roma, Peter G.; Armour, Elwood; Gooden, Virginia L.; Brady, Joseph V.; Weed, Michael R.; Hienz, Robert D.

    2014-01-01

    The present report describes an animal model for examining the effects of radiation on a range of neurocognitive functions in rodents that are similar to a number of basic human cognitive functions. Fourteen male Long-Evans rats were trained to perform an automated intra-dimensional set shifting task that consisted of their learning a basic discrimination between two stimulus shapes followed by more complex discrimination stages (e.g., a discrimination reversal, a compound discrimination, a compound reversal, a new shape discrimination, and an intra-dimensional stimulus discrimination reversal). One group of rats was exposed to head-only X-ray radiation (2.3 Gy at a dose rate of 1.9 Gy/min), while a second group received a sham-radiation exposure using the same anesthesia protocol. The irradiated group responded less, had elevated numbers of omitted trials, increased errors, and greater response latencies compared to the sham-irradiated control group. Additionally, social odor recognition memory was tested after radiation exposure by assessing the degree to which rats explored wooden beads impregnated with either their own odors or with the odors of novel, unfamiliar rats; however, no significant effects of radiation on social odor recognition memory were observed. These data suggest that rodent tasks assessing higher-level human cognitive domains are useful in examining the effects of radiation on the CNS, and may be applicable in approximating CNS risks from radiation exposure in clinical populations receiving whole brain irradiation. PMID:25099152

  10. The Structure of Urease Activation Complexes Examined by Flexibility Analysis, Mutagenesis, and Small-angle X-ray Scattering Approaches

    International Nuclear Information System (INIS)

    Quiroz, Soledad; Sukuru, Sai Chetan K.; Hausinger, Robert P.; Kuhn, Leslie A.; Heller, William T

    2008-01-01

    Conformational changes of Klebsiella aerogenes urease apoprotein (UreABC) 3 induced upon binding of the UreD and UreF accessory proteins were examined by a combination of flexibility analysis, mutagenesis, and small-angle X-ray scattering (SAXS). ProFlex analysis of urease provided evidence that the major domain of UreB can move in a hinge-like motion to account for prior chemical cross-linking results. Rigidification of the UreB hinge region, accomplished through a G11P mutation, reduced the extent of urease activation, in part by decreasing the nickel content of the mutant enzyme, and by sequestering a portion of the urease apoprotein in a novel activation complex that includes all of the accessory proteins. SAXS analyses of urease, (UreABC-UreD) 3 , and (UreABC-UreDF) 3 confirm that UreD and UreF bind near UreB at the periphery of the (UreAC) 3 structure. This study supports an activation model in which a domain-shifted UreB conformation in (UreABC-UreDF) 3 allows CO 2 and nickel ions to gain access to the nascent active site

  11. X-ray standing wave simulations based on Fourier vector analysis as a method to retrieve complex molecular adsorption geometries

    Directory of Open Access Journals (Sweden)

    Giuseppe eMercurio

    2014-01-01

    Full Text Available We present an analysis method of normal incidence x-ray standing wave (NIXSW data that allows detailed adsorption geometries of complex molecules to be retrieved. This method (Fourier vector analysis is based on the comparison of both the coherence and phase of NIXSW data to NIXSW simulations of different molecular geometries as the relevant internal degrees of freedom are tuned. We introduce this analysis method using the prototypical molecular switch azobenzene (AB adsorbed on the Ag(111 surface as a model system. The application of the Fourier vector analysis to AB/Ag(111 provides, on the one hand, detailed adsorption geometries including dihedral angles, and on the other hand, insights into the dynamics of molecules and their bonding to the metal substrate. This analysis scheme is generally applicable to any adsorbate, it is necessary for molecules with potentially large distortions, and will be particularly valuable for molecules whose distortion on adsorption can be mapped on a limited number of internal degrees of freedom.

  12. Effects of X-ray radiation on complex visual discrimination learning and social recognition memory in rats.

    Directory of Open Access Journals (Sweden)

    Catherine M Davis

    Full Text Available The present report describes an animal model for examining the effects of radiation on a range of neurocognitive functions in rodents that are similar to a number of basic human cognitive functions. Fourteen male Long-Evans rats were trained to perform an automated intra-dimensional set shifting task that consisted of their learning a basic discrimination between two stimulus shapes followed by more complex discrimination stages (e.g., a discrimination reversal, a compound discrimination, a compound reversal, a new shape discrimination, and an intra-dimensional stimulus discrimination reversal. One group of rats was exposed to head-only X-ray radiation (2.3 Gy at a dose rate of 1.9 Gy/min, while a second group received a sham-radiation exposure using the same anesthesia protocol. The irradiated group responded less, had elevated numbers of omitted trials, increased errors, and greater response latencies compared to the sham-irradiated control group. Additionally, social odor recognition memory was tested after radiation exposure by assessing the degree to which rats explored wooden beads impregnated with either their own odors or with the odors of novel, unfamiliar rats; however, no significant effects of radiation on social odor recognition memory were observed. These data suggest that rodent tasks assessing higher-level human cognitive domains are useful in examining the effects of radiation on the CNS, and may be applicable in approximating CNS risks from radiation exposure in clinical populations receiving whole brain irradiation.

  13. Application of X-ray single crystal diffractometry to investigation of Np(5) complexes with n-donor ligands

    International Nuclear Information System (INIS)

    Andreev, G.

    2007-01-01

    Full text of publication follows. We present here some results of application of conventional X-ray single crystal diffractometry to the research on the interaction of Np(V) with N-donor ligands. Compounds that can coordinate to actinides through one or several nitrogen atoms are of a great variety and occur widely in the biosphere. For example, imidazole, pyridine and their derivatives are the building blocks of many biologically important molecules; triazines are known to occur in some aquatic plants. The presence of anthropogenic organic agents like amine-N-carboxylic acids in surface waters has the potential to re-mobilize metals from sediments and aquifers and to influence their bioavailability. The interaction of radionuclides with such ligands needs to be studied in detail to give fundamental understanding the conditions of the incorporation of long lived a-emitters (Np and Pu primarily) into the food chain. Another aspect of the same problem is the design of new chelating ligands for selective co-ordination of actinide ions as an alternative to the traditional sequestering agents. The problem of the separation of long-lived minor actinides and their transmutation also calls for design of new highly selective ligands for solvent extraction. Polydentate N-donor ligands are now considered to be very promising. A detailed study of structural chemistry is crucial for understanding the relationship between the architecture of the ligands and their binding affinity for actinides. The X-ray single crystal diffractometry became conventional technique as applied to the investigation of actinides in spite of difficulties regarding safe handling of radionuclides. This technique provides unambiguous information about modes of the ligand co-ordination to the metal ion and geometrical parameters of complexes. Moreover, the employment of a synchrotron radiation shows considerable promise for determination of solid state structures as well as obtaining structural

  14. Characteristic Ligand-Induced Crystal Forms of HIV-1 Protease Complexes: A Novel Discovery of X-Ray Crystallography

    International Nuclear Information System (INIS)

    Olajuyigbe, Folasade M.; Geremia, Silvano

    2009-10-01

    Mixtures of saquinavir (SQV) and ritonavir (RTV) were cocrystallized with HIV-1 protease (PR) in an attempt to compare their relative potencies using a crystallographic approach and factors responsible for the respective crystal forms obtained were examined. The mixture ratio of the SQV/RTV was in the range of 1:1 to 1:50 with increasing concentration of dimethyl sulphoxide (DMSO) used. Two crystal forms of PR complexes were obtained. At concentrations of 0.8 and 1.2 % DMSO using 1:1 and 1:15 ratios of SQV/RTV, the crystal form was monoclinic while increasing the concentration of DMSO to 3.2 and 5.0% using 1:15 and 1:50 ratios of SQV/RTV, the orthorhombic crystal form was obtained. The high resolution X-ray crystal structures of the PR/ inhibitor complexes reveal that crystal forms with respective space groups are dependent on the occupancy of either SQV or RTV in the active site of the PR. The occupancy of either of the PR inhibitors in the active site of PR has interestingly demonstrated unique cooperativity effects in crystallization of protein-ligand complexes. The crystal forms obtained were also related to the concentration of DMSO and ammonium sulphate in crystallization, and storage conditions of purified PR. Surprisingly, the relative occupancies of these inhibitors in the active site suggested a competition between the two inhibitors which were not inhibition constants related. Analysis of the structures in both crystal forms show no difference in DMSO content but at higher concentration of DMSO (3.2 - 5.0%) in the orthorhombic crystal forms, there were protein-sulphate interactions which were absent in the monoclinic forms with lower concentration (0.8 - 1.2%) of DMSO. This work has clearly demonstrated that there is cooperativity in crystallization and the conditions of crystallization influence specific intermolecular contacts in crystal packing (crystal form). (author)

  15. Complex optical/UV and X-ray variability of the Seyfert 1 galaxy 1H 0419-577

    Science.gov (United States)

    Pal, Main; Dewangan, Gulab C.; Kembhavi, Ajit K.; Misra, Ranjeev; Naik, Sachindra

    2018-01-01

    We present detailed broad-band UV/optical to X-ray spectral variability of the Seyfert 1 galaxy 1H 0419-577 using six XMM-Newton observations performed during 2002-2003. These observations covered a large amplitude variability event in which the soft X-ray (0.3-2 keV) count rate increased by a factor of ∼4 in six months. The X-ray spectra during the variability are well described by a model consisting of a primary power law, blurred and distant reflection. The 2-10 keV power-law flux varied by a factor of ∼7 while the 0.3-2 keV soft X-ray excess flux derived from the blurred reflection component varied only by a factor of ∼2. The variability event was also observed in the optical and UV bands but the variability amplitudes were only at the 6-10 per cent level. The variations in the optical and UV bands appear to follow the variations in the X-ray band. During the rising phase, the optical bands appear to lag behind the UV band but during the declining phase, the optical bands appear to lead the UV band. Such behaviour is not expected in the reprocessing models where the optical/UV emission is the result of reprocessing of X-ray emission in the accretion disc. The delayed contribution of the broad emission lines in the UV band or the changes in the accretion disc/corona geometry combined with X-ray reprocessing may give rise to the observed behaviour of the variations.

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  17. Probing the Impact of Solvation on Photoexcited Spin Crossover Complexes with High-Precision X-ray Transient Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Cunming; Zhang, Jianxin [State; Lawson Daku, Latévi M. [Département; Gosztola, David; Canton, Sophie E. [ELI-ALPS, ELI-HU Non-Profit Ltd., Dugonics ter 13, Szeged 6720, Hungary; Attosecond; Zhang, Xiaoyi

    2017-11-17

    Investigating the photoinduced electronic and structural response of bistable molecular building blocks incorporating transition metals in solution phase constitutes a necessary stepping stone for steering their properties towards applications and perfomance optimizations. This work presents a detailed X-ray transient absorption (XTA) spectroscopy study of a prototypical spin crossover (SCO) complex [FeII(mbpy)3]2+ (where mbpy=4,4’-dimethyl-2,2’-bipyridine) with a [FeIIN6] first coordination shell in water (H2O) and acetonitrile (CH3CN). The unprecedented data quality of the XTA spectra together with the direct fitting of the difference spectra in k space using a large number of scattering paths enables resolving the subtle difference in the photoexcited structures of an FeII complex in two solvents for the first time. Compared to the low spin (LS) 1A1 state, the average Fe-N bond elongations for the photoinduced high spin (HS) 5T2 state are found to be 0.181 . 0.003 Å in H2O and 0.199 . 0.003 Å in CH3CN. This difference in structural response is attributed to ligand-solvent interactions that are stronger in H2O than in CH3CN for the HS excited state. Our studies demonstrate that, although the metal center of [FeII(mbpy)3]2+ could have been expected to be rather shielded by the three bidentate ligands with quasi-octahedral-coordination, the ligand field strength in the HS excited state is nevertheless indirectly affected by solvation that modifies the charge distribution within the Fe-N covalent bonds. More generally, this work highlights the importance of including solvation effects in order to develop a generalized understanding of the spin-state switching at the atomic level.

  18. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  19. UV-visible spectroscopic estimation of photodegradation of rhodamine-B dye using tin(IV) oxide nanoparticles.

    Science.gov (United States)

    Sangami, G; Dharmaraj, N

    2012-11-01

    Nanocrystalline, tin(IV) oxide (SnO(2)) particles has been prepared by thermal decomposition of tin oxalate precursor obtained from the reactions of tin(IV) chloride and sodium oxalate using eggshell membrane (ESM). The as-prepared SnO(2) nanoparticles were characterized by thermal studies, transmission electron microscopy (TEM), powder X-ray diffraction (XRD), Raman, FT-IR and UV-visible studies and used as a photocatalyst for the degradation of rhodamine-B (Rh-B) dye. The size of the prepared nanoparticles was in the range of 5-12nm as identified from the TEM images. Powder XRD data revealed the presence of a tetragonal, rutile crystalline phase of the tin(IV) oxide nanoparticles. Thermal analysis showed that the decomposition of tin oxalate precursor to yield the titled tin(IV) oxide nanoparticles was completed below 500°C. The extent of degradation of Rh-B in the presence of SnO(2) monitored by absorption spectral measurements demonstrated that 94.48% of the selected dye was degraded upon irradiation with UV light for 60 min. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. The complex radio and X-ray structure in the nuclear regions of the active galaxy NGC 1365

    Science.gov (United States)

    Stevens, Ian R.; Forbes, Duncan A.; Norris, Ray P.

    1999-06-01

    We present a multiwavelength analysis of the prominent active galaxy NGC 1365, in particular looking at the radio and X-ray properties of the central regions of the galaxy. We analyse ROSAT (PSPC and HRI) observations of NGC 1365, and discuss recent ASCA results. In addition to a number of point sources in the vicinity of NGC 1365, we find a region of extended X-ray emission extending along the central bar of the galaxy, combined with an emission peak near the centre of the galaxy. This central X-ray emission is centred on the optical/radio nucleus, but is spatially extended. The X-ray spectrum can be well fitted by a thermal plasma model, with a temperature of kT=0.6-0.8 keV and a very low local absorbing column. The thermal spectrum is suggestive of starburst emission rather than emission from a central black hole. The ATCA radio observations show a number of hotspots, located in a ring around a weak radio nucleus. Synchrotron emission from electrons accelerated by supernovae and supernova remnants (SNRs) is the likely origin of these hotspots. The radio nucleus has a steep spectrum, indicative perhaps of an active galactic nucleus (AGN) or SNRs. The evidence for a jet emanating from the nucleus (as has been previously claimed) is at best marginal. The extent of the radio ring is comparable to that of the extended central X-ray source. We discuss the nature of the central activity in NGC 1365 in the light of these observations. The extended X-ray emission and the thermal spectra strongly suggest that at soft X-ray energies we are not seeing emission predominantly from a central black hole, although the presence of Fe K line emission at higher energies does suggest the presence of an AGN. Consequently, a black hole is probably not the dominant contributor to the energetics of the central regions of NGC 1365 at radio, optical or soft X-ray wavelengths. Activity associated with a starburst is likely the dominant explanation for the observed properties of NGC 1365.

  1. Purification, crystallization and preliminary X-ray crystallographic analysis of the ATPase domain of human TAP in nucleotide-free and ADP-, vanadate- and azide-complexed forms

    International Nuclear Information System (INIS)

    Meena, Sita R.; Gangwar, Shanti P.; Saxena, Ajay K.

    2012-01-01

    The ATPase domain of human TAP in nucleotide free, ADP, vanadate and azide complexed forms were purified and crystallized. The X-ray diffraction data sets were collected for all crystals in the resolution range of 2.8–3.0 Å. The human transporter associated with antigen processing (TAP) protein belongs to the ATP-binding cassette (ABC) transporter superfamily and is formed by the heterodimerization of TAP1 and TAP2 subunits. TAP selectively pumps cytosolic peptides into the lumen of the endoplasmic reticulum in an ATP-dependent manner. The catalytic cycle of the ATPase domain of TAP is not understood at the molecular level. The structures of catalytic intermediates of the ATPase domain of TAP will contribute to the understanding of the chemical mechanism of ATP hydrolysis. In order to understand this mechanism, the ATPase domain of human TAP1 (NBD1) was expressed and purified, crystallized in nucleotide-free and transition-state complex forms and X-ray crystallographic studies were performed. The NBD1 protein was crystallized (i) in the nucleotide-free apo form; (ii) in complex with ADP–Mg 2+ , mimicking the product-bound state; (iii) in complex with vanadate–ADP–Mg 2+ , mimicking the ATP-bound state; and (iv) in complex with azide–ADP–Mg 2+ , also mimicking the ATP-bound state. X-ray diffraction data sets were collected for apo and complexed NBD1 using an in-house X-ray diffraction facility at a wavelength of 1.5418 Å. The apo and complexed NBD1 crystals belonged to the primitive hexagonal space group P6 2 , with one monomer in the asymmetric unit. Here, the crystallization, data collection and preliminary crystallographic analysis of apo and complexed NBD1 are reported

  2. Complex regional pain syndrome in a competitive athlete and regional osteoporosis assessed by dual-energy X-ray absorptiometry: a case report.

    Science.gov (United States)

    Hind, Karen; Johnson, Mark I

    2014-05-27

    Dual-energy X-ray absorptiometry is rarely utilized in the clinical care of patients with complex regional pain syndrome, but may be useful for the non-invasive determination of regional bone fragility and fracture risk, as well as muscular atrophy and regional body composition. This is the first report in the literature of complex regional pain syndrome and musculoskeletal co-morbidities in an athlete, and is the first to focus on dual-energy X-ray absorptiometry for the clinical assessment of complex regional pain syndrome. In this report, we describe the case of a 29-year-old Caucasian man with type 1 complex regional pain syndrome. His body mass index was 29.4kg/m2 at the time of presentation. Despite severe complex regional pain syndrome in the left limb and long term use of a wheelchair, the patient participated in high-performance powerlifting. Dual-energy X-ray absorptiometry revealed marked unilateral differences in bone strength and lean mass between the affected regions and the contralateral regions. Low bone mineral density for age was found in the left hip, with Z-scores ranging from -2.2 to -3.0, and the patient had previously suffered two fractures. Bone density Z-scores in the right hip and legs were normal. Dual-energy X-ray absorptiometry is a valuable tool for the clinical investigation of musculoskeletal health in patients with complex regional pain syndrome. Regional osteoporosis in complex regional pain syndrome patients is complicated and should be investigated and monitored. Physical activity is possible for some complex regional pain syndrome patients, depending on the type of exercise and the region affected, and it may protect bone density and strength at non affected skeletal sites.

  3. Iron L2,3-Edge X-ray Absorption and X-ray Magnetic Circular Dichroism Studies of Molecular Iron Complexes with Relevance to the FeMoco and FeVco Active Sites of Nitrogenase.

    Science.gov (United States)

    Kowalska, Joanna K; Nayyar, Brahamjot; Rees, Julian A; Schiewer, Christine E; Lee, Sonny C; Kovacs, Julie A; Meyer, Franc; Weyhermüller, Thomas; Otero, Edwige; DeBeer, Serena

    2017-07-17

    Herein, a systematic study of a series of molecular iron model complexes has been carried out using Fe L 2,3 -edge X-ray absorption (XAS) and X-ray magnetic circular dichroism (XMCD) spectroscopies. This series spans iron complexes of increasing complexity, starting from ferric and ferrous tetrachlorides ([FeCl 4 ] -/2- ), to ferric and ferrous tetrathiolates ([Fe(SR) 4 ] -/2- ), to diferric and mixed-valent iron-sulfur complexes [Fe 2 S 2 R 4 ] 2-/3- . This test set of compounds is used to evaluate the sensitivity of both Fe L 2,3 -edge XAS and XMCD spectroscopy to oxidation state and ligation changes. It is demonstrated that the energy shift and intensity of the L 2,3 -edge XAS spectra depends on both the oxidation state and covalency of the system; however, the quantitative information that can be extracted from these data is limited. On the other hand, analysis of the Fe XMCD shows distinct changes in the intensity at both L 3 and L 2 edges, depending on the oxidation state of the system. It is also demonstrated that the XMCD intensity is modulated by the covalency of the system. For mononuclear systems, the experimental data are correlated with atomic multiplet calculations in order to provide insights into the experimental observations. Finally, XMCD is applied to the tetranuclear heterometal-iron-sulfur clusters [MFe 3 S 4 ] 3+/2+ (M = Mo, V), which serve as structural analogues of the FeMoco and FeVco active sites of nitrogenase. It is demonstrated that the XMCD data can be utilized to obtain information on the oxidation state distribution in complex clusters that is not readily accessible for the Fe L 2,3 -edge XAS data alone. The advantages of XMCD relative to standard K-edge and L 2,3 -edge XAS are highlighted. This study provides an important foundation for future XMCD studies on complex (bio)inorganic systems.

  4. Iron L2,3-Edge X-ray Absorption and X-ray Magnetic Circular Dichroism Studies of Molecular Iron Complexes with Relevance to the FeMoco and FeVco Active Sites of Nitrogenase

    Science.gov (United States)

    2017-01-01

    Herein, a systematic study of a series of molecular iron model complexes has been carried out using Fe L2,3-edge X-ray absorption (XAS) and X-ray magnetic circular dichroism (XMCD) spectroscopies. This series spans iron complexes of increasing complexity, starting from ferric and ferrous tetrachlorides ([FeCl4]−/2–), to ferric and ferrous tetrathiolates ([Fe(SR)4]−/2–), to diferric and mixed-valent iron–sulfur complexes [Fe2S2R4]2–/3–. This test set of compounds is used to evaluate the sensitivity of both Fe L2,3-edge XAS and XMCD spectroscopy to oxidation state and ligation changes. It is demonstrated that the energy shift and intensity of the L2,3-edge XAS spectra depends on both the oxidation state and covalency of the system; however, the quantitative information that can be extracted from these data is limited. On the other hand, analysis of the Fe XMCD shows distinct changes in the intensity at both L3 and L2 edges, depending on the oxidation state of the system. It is also demonstrated that the XMCD intensity is modulated by the covalency of the system. For mononuclear systems, the experimental data are correlated with atomic multiplet calculations in order to provide insights into the experimental observations. Finally, XMCD is applied to the tetranuclear heterometal–iron–sulfur clusters [MFe3S4]3+/2+ (M = Mo, V), which serve as structural analogues of the FeMoco and FeVco active sites of nitrogenase. It is demonstrated that the XMCD data can be utilized to obtain information on the oxidation state distribution in complex clusters that is not readily accessible for the Fe L2,3-edge XAS data alone. The advantages of XMCD relative to standard K-edge and L2,3-edge XAS are highlighted. This study provides an important foundation for future XMCD studies on complex (bio)inorganic systems. PMID:28653855

  5. Photoinduced charge transfer in a transition metal complex investigated by time-resolved X-ray absorption fine structure spectroscopy. Setup and experiment

    International Nuclear Information System (INIS)

    Goeries, Dennis

    2015-02-01

    In the framework of this thesis the development of a time-resolved X-ray absorption spectroscopy experiment and its application to fac-Ir(ppy) 3 is described. Such experiments require a very stable setup in terms of spatial and temporal accuracy. Therefore, the stability properties of the present installation were investigated in detail and continuously improved, in particular the synchronization of the ultrashort pulse laser system to the storage ring as well as the spatial stability of both X-ray and laser beam. Experiments utilizing the laser pump and X-ray probe configuration were applied on the green phosphorescence emitter complex fac-Ir(ppy) 3 dissolved in dimethyl sulfoxide. Structural and electronic changes were triggered by photoexcitation of the metal-to-ligand charge transfer band with ultrashort laser pulses at a wavelength of 343 nm. The excited triplet state spectrum was extracted from the measured pump-probe X-ray absorption spectrum using an ionic approximation. The results con rm the anticipated metal-to-ligand charge transfer as shown by an ionization potential shift of the iridium atom. The symmetry of the complex was found to be pseudo-octahedral. This allowed the first experimental determination of the bond length of fac-Ir(ppy) 3 in an octahedral approximation and revealed a decrease of bond length of the first coordination shell in the triplet state. The first and second-order decay kinetics of the triplet state were investigated in a combination of X-ray and laser based experiments and revealed self-quenching as well as triplet-triplet annihilation rate constants.

  6. Rhenium complexes of chromophore-appended dipicolylamine ligands: syntheses, spectroscopic properties, DNA binding and X-ray crystal structure

    International Nuclear Information System (INIS)

    Mullice, L.A.; Buurma, N.J.; Pope, S.J.A.; Laye, R.H.; Harding, L.P.

    2008-01-01

    The syntheses of two chromophore-appended dipicolylamine-derived ligands and their reactivity with penta-carbonyl-chloro-rhenium have been studied. The resultant complexes each possess the fac-Re(CO) 3 core. The ligands L 1 1-[bis(pyridine-2-yl-methyl)amino]methyl-pyrene and L 2 2-[bis(pyridine-2-yl-methyl)amino]methyl-quinoxaline were isolated via a one-pot reductive amination in moderate yield. The corresponding rhenium complexes were isolated in good yields and characterised by 1 H NMR, MS, IR and UV-Vis studies. X-Ray crystallographic data were obtained for fac-{Re(CO) 3 (L 1 )}(BF 4 ), C 34 H 26 BF 4 N 4 O 3 Re: monoclinic, P2(1)/c, a 18.327(2) Angstroms, α = 90.00 degrees, b 14.1537(14) Angstroms, β96.263(6) degrees, c = 23.511(3) Angstroms, γ 90.00 Angstroms, 6062.4(11) (Angstroms) 3 , Z=8. The luminescence properties of the ligands and complexes were also investigated, with the emission attributed to the appended chromophore in each case. Isothermal titration calorimetry suggests that fac-{Re(CO) 3 (L 1 )}(BF 4 ) self-aggregates cooperatively in aqueous solution, probably forming micelle-like aggregates with a cmc of 0.18 mM. Investigations into the DNA-binding properties of fac-{Re(CO) 3 (L 1 )}(BF 4 ) were undertaken and revealed that fac-{Re(CO) 3 (L 1 )}(BF 4 ) binding to fish sperm DNA (binding constant 1.5 ± 0.2 * 10 5 M -1 , binding site size 3.2 ± 0.3 base pairs) is accompanied by changes in the UV-Vis spectrum as typically observed for pyrene-based intercalators while the calorimetrically determined binding enthalpy (-14 ± 2 kcal mol -1 ) also agrees favourably with values as typically found for intercalators. (authors)

  7. Crystallization and preliminary X-ray diffraction studies of Drosophila melanogaster Gαo-subunit of heterotrimeric G protein in complex with the RGS domain of CG5036

    International Nuclear Information System (INIS)

    Tishchenko, Svetlana; Gabdulkhakov, Azat; Tin, Uliana; Kostareva, Olga; Lin, Chen; Katanaev, Vladimir L.

    2012-01-01

    D. melanogaster Gαo-subunit and the RGS domain of its interacting partner CG5036 have been overproduced and purified; the crystallization and preliminary X-ray crystallographic analysis of the complex of the two proteins are reported. Regulator of G-protein signalling (RGS) proteins negatively regulate heterotrimeric G-protein signalling through their conserved RGS domains. RGS domains act as GTPase-activating proteins, accelerating the GTP hydrolysis rate of the activated form of Gα-subunits. Although omnipresent in eukaryotes, RGS proteins have not been adequately analysed in non-mammalian organisms. The Drosophila melanogaster Gαo-subunit and the RGS domain of its interacting partner CG5036 have been overproduced and purified; the crystallization of the complex of the two proteins using PEG 4000 as a crystallizing agent and preliminary X-ray crystallographic analysis are reported. Diffraction data were collected to 2.0 Å resolution using a synchrotron-radiation source

  8. X-ray holography

    CERN Document Server

    Faigel, G; Belakhovsky, M; Marchesini, S; Bortel, G

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples.

  9. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  10. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  11. Complex assembly, crystallization and preliminary X-ray crystallographic analysis of the human Rod-Zwilch-ZW10 (RZZ) complex.

    Science.gov (United States)

    Altenfeld, Anika; Wohlgemuth, Sabine; Wehenkel, Annemarie; Vetter, Ingrid R; Musacchio, Andrea

    2015-04-01

    The spindle-assembly checkpoint (SAC) monitors kinetochore-microtubule attachment during mitosis. In metazoans, the three-subunit Rod-Zwilch-ZW10 (RZZ) complex is a crucial SAC component that interacts with additional SAC-activating and SAC-silencing components, including the Mad1-Mad2 complex and cytoplasmic dynein. The RZZ complex contains two copies of each subunit and has a predicted molecular mass of ∼800 kDa. Given the low abundance of the RZZ complex in natural sources, its recombinant reconstitution was attempted by co-expression of its subunits in insect cells. The RZZ complex was purified to homogeneity and subjected to systematic crystallization attempts. Initial crystals containing the entire RZZ complex were obtained using the sitting-drop method and were subjected to optimization to improve the diffraction resolution limit. The crystals belonged to space group P3₁ (No. 144) or P3₂ (No. 145), with unit-cell parameters a = b = 215.45, c = 458.7 Å, α = β = 90.0, γ = 120.0°.

  12. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... loose, comfortable clothing. You may be asked to change into a gown. You may have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny ...

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  15. INVESTIGATING THE COMPLEX X-RAY SPECTRUM OF A BROAD-LINE 2MASS RED QUASAR: XMM-NEWTON OBSERVATION OF FTM 0830+3759

    International Nuclear Information System (INIS)

    Piconcelli, Enrico; Nicastro, Fabrizio; Fiore, Fabrizio; Vignali, Cristian; Bianchi, Stefano; Miniutti, Giovanni

    2010-01-01

    We report results from a 50 ks XMM-Newton observation of the dust-reddened broad-line quasar FTM 0830+3759 (z = 0.413) selected from the Faint Images of the Radio Sky at Twenty cm/Two Micron All Sky Survey red quasar survey. For this active galactic nucleus (AGN), a very short 9 ks Chandra exposure had suggested a feature-rich X-ray spectrum and Hubble Space Telescope images revealed a very disturbed host galaxy morphology. Contrary to classical, optically selected quasars, the X-ray properties of red (i.e., with J - K s > 1.7 and R - K s > 4.0) broad-line quasars are still quite unexplored, although there is a growing consensus that, due to moderate obscuration, these objects can offer a unique view of spectral components typically swamped by the AGN light in normal, blue quasars. The XMM-Newton observation discussed here has definitely confirmed the complexity of the X-ray spectrum revealing the presence of a cold (or mildly ionized) absorber with N H ∼ 10 22 cm -2 along the line of sight to the nucleus and a Compton reflection component accompanied by an intense Fe Kα emission line in this quasar with a L 2-10 k eV ∼ 5 x 10 44 erg s -1 . A soft-excess component is also required by the data. The match between the column density derived by our spectral analysis and that expected on the basis of reddening due to the dust suggests the possibility that both absorptions occur in the same medium. FTM 0830+3759 is characterized by an extinction/absorption-corrected X-ray-to-optical flux ratio α ox = -2.3, which is steeper than expected on the basis of its UV luminosity. These findings indicate that the X-ray properties of FTM 0830+3759 differ from those typically observed for optically selected broad-line quasars with comparable hard X-ray luminosity.

  16. Complex assembly, crystallization and preliminary X-ray crystallographic studies of rhesus macaque MHC Mamu-A*01 complexed with an immunodominant SIV-Gag nonapeptide

    International Nuclear Information System (INIS)

    Chu, Fuliang; Lou, Zhiyong; Gao, Bin; Bell, John I.; Rao, Zihe; Gao, George F.

    2005-01-01

    Crystallization of the first rhesus macaque MHC class I complex. Simian immunodeficiency virus (SIV) infection in rhesus macaques has been used as the best model for the study of human immunodeficiency virus (HIV) infection in humans, especially in the cytotoxic T-lymphocyte (CTL) response. However, the structure of rhesus macaque (or any other monkey model) major histocompatibility complex class I (MHC I) presenting a specific peptide (the ligand for CTL) has not yet been elucidated. Here, using in vitro refolding, the preparation of the complex of the rhesus macaque MHC I allele (Mamu-A*01) with human β 2 m and an immunodominant peptide, CTPYDINQM (Gag-CM9), derived from SIV Gag protein is reported. The complex (45 kDa) was crystallized; the crystal belongs to space group I422, with unit-cell parameters a = b = 183.8, c = 155.2 Å. The crystal contains two molecules in the asymmetric unit and diffracts X-rays to 2.8 Å resolution. The structure is being solved by molecular replacement and this is the first attempt to determined the crystal structure of a peptide–nonhuman primate MHC complex

  17. A Fast, Versatile Nanoprobe for Complex Materials: The Sub-micron Resolution X-ray Spectroscopy Beamline at NSLS-II (491st Brookhaven Lecture)

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Juergen [BNL Photon Sciences Directorate

    2014-02-06

    Time is money and for scientists who need to collect data at research facilities like Brookhaven Lab’s National Synchrotron Light Source (NSLS), “beamtime” can be a precious commodity. While scanning a complex material with a specific technique and standard equipment today would take days to complete, researchers preparing to use brighter x-rays and the new sub-micron-resolution x-ray spectroscopy (SRX) beamline at the National Synchrotron Light Source II (NSLS-II) could scan the same sample in greater detail with just a few hours of beamtime. Talk about savings and new opportunities for researchers! Users will rely on these tools for locating trace elements in contaminated soils, developing processes for nanoparticles to deliver medical treatments, and much more. Dr. Thieme explains benefits for next-generation research with spectroscopy and more intense x-rays at NSLS-II. He discusses the instrumentation, features, and uses for the new SRX beamline, highlighting its speed, adjustability, and versatility for probing samples ranging in size from millimeters down to the nanoscale. He will talk about complementary beamlines being developed for additional capabilities at NSLS-II as well.

  18. Non-destructive failure analysis and measurement for molded devices and complex assemblies with X-ray CT and 3D image processing techniques

    International Nuclear Information System (INIS)

    Yin, Xiaoming; Liew, Seaw Jia; Jiang, Ting Ying; Xu, Jian; Kakarala, Ramakrishna

    2013-01-01

    In both automotive and healthcare sectors, reliable failure analysis and accurate measurement of molded devices and complex assemblies are important. Current methods of failure analysis and measurement require these molded parts to be cross-sectioned so that internal features or dimensions can be accessible. As a result, the parts are deemed unusable and additional failure introduced by sectioning may cause misinterpretation of the results. X-ray CT and 3D image processing techniques provide a new nondestructive solution for failure analysis and measurement of molded devices and complex assemblies. These techniques simplify failure analysis and measurement of molded devices and assemblies, and improve the productivity of molding manufacturing significantly.

  19. X-ray generator

    International Nuclear Information System (INIS)

    Dawson, J.M.

    1976-01-01

    An apparatus and a method are described for producing coherent secondary x-rays that are controlled as to direction by illuminating a mixture of high z and low z gases with an intense burst of primary x-rays. The primary x-rays are produced with a laser activated plasma, and these x-rays strip off the electrons of the high z atoms in the lasing medium, while the low z atoms retain their electrons. The neutral atoms transfer electrons to highly excited states of the highly stripped high z ions giving an inverted population which produces the desired coherent x-rays. In one embodiment, a laser, light beam provides a laser spark that produces the intense burst of coherent x-rays that illuminates the mixture of high z and low z gases, whereby the high z atoms are stripped while the low z ones are not, giving the desired mixture of highly ionized and neutral atoms. Means for magnetically confining and stabilizing the plasma are disclosed for controlling the direction of the x-rays

  20. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  1. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  2. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  4. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small ... limitations of Panoramic X-ray? What is Panoramic X-ray? Panoramic radiography , also called panoramic x-ray , is ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  6. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  7. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  8. X-Ray Exam: Hip

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: ... darker. An X-ray technician takes the X-rays. An X-ray technician in the radiology department of a ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  10. Lumbosacral spine x-ray

    Science.gov (United States)

    X-ray - lumbosacral spine; X-ray - lower spine ... The test is done in a hospital x-ray department or your health care provider's office by an x-ray technician. You will be asked to lie on the x-ray table ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  12. Isolation and X-ray structures of four Rh(PCP) complexes including a Rh(I) dioxygen complex with a short O-O bond

    KAUST Repository

    Hayashi, Yukiko

    2013-07-01

    The reaction of RhCl3·H2O with tBu2P(CH2)5PtBu 2 afforded several complexes including [RhIII(H)Cl{ tBu2- P(CH2)2CH(CH2) 2PtBu2}] (1), [RhIIIHCl 2{tBu2P(CH2)5P tBu2}]2 (2), [RhICl{ tBu2P(CH2)2CH=CHCH2P tBu2}] (3) and [RhICl{tBu 2PCH2C(O)CH=CHCH2PtBu2}] (4). X-ray crystal structures of 3 and 4 showed that the C=C bond on the C 5 unit of tBu2P(CH2) 5PtBu2 is bound to Rh(I) in a η2 configuration. In 4, the Rh atom has a trigonal pyramidal coordination geometry. The X-ray crystal structure of 2 consists of two rhodium( III) centers bridged by two tBu2P(CH2)5P tBu2 ligands with two phosphorus atoms, one from each ligand, trans to one another. The crystal structure of the rhodium oxygen adduct with 1,3-bis(di-t-butylphosphinomethyl) benzene [RhO2{ tBu2PCH2(C6H3)CH 2PtBu2}] (5) was also investigated. In this species the O2 is η2 coordinated to the Rh(I) center with asymmetric Rh-O bond lengths (2.087(7) and 1.998(8) Å). The O-O bond distance is short (1.337(11) Å) with νO-O of 990.5 cm -1. DFT calculations on complex 5 yielded two η2- O2 structures that differed in energy by only 0.76 kcal/mol. The lower energy one (5a) had near C2 symmetry, and had nearly equal Rh-O bond lengths, while the higher energy structure (5b) had near Cs symmetry and generally good agreement with the experimental structure. The calculated UV-Vis and IR spectra of complex 5 are in excellent agreement with experiment. © 2012 Elsevier Ltd. All rights reserved.

  13. New Cu (II), Co(II) and Ni(II) complexes of chalcone derivatives: Synthesis, X-ray crystal structure, electrochemical properties and DFT computational studies

    Science.gov (United States)

    Tabti, Salima; Djedouani, Amel; Aggoun, Djouhra; Warad, Ismail; Rahmouni, Samra; Romdhane, Samir; Fouzi, Hosni

    2018-03-01

    The reaction of nickel(II), copper(II) and cobalt(II) with 4-hydroxy-3-[(2E)-3-(1H-indol-3-yl)prop-2-enoyl]-6-methyl-2H-pyran-2-one (HL) leads to a series of new complexes: Ni(L)2(NH3), Cu(L)2(DMF)2 and Co(L)2(H2O). The crystal structure of the Cu(L)2(DMF)2 complex have been determined by X-ray diffraction methods. The Cu(II) lying on an inversion centre is coordinated to six oxygen atoms forming an octahedral elongated. Additionally, the electrochemical behavior of the metal complexes were investigated by cyclic voltammetry at a glassy carbon electrode (GC) in CH3CN solutions, showing the quasi-reversible redox process ascribed to the reduction of the MII/MI couples. The X-ray single crystal structure data of the complex was matched excellently with the optimized monomer structure of the desired compound; Hirschfeld surface analysis supported the packed crystal lattice 3D network intermolecular forces. HOMO/LUMO energy level and the global reactivity descriptors quantum parameters are also calculated. The electrophilic and nucleophilic potions in the complex surface are theoretically evaluated by molecular electrostatic potential and Mulliken atomic charges analysis.

  14. X-ray interferometric Fourier holography

    International Nuclear Information System (INIS)

    Balyan, M.K.

    2016-01-01

    The X-ray interferometric Fourier holography is proposed and theoretically investigated. Fourier The X-ray interferometric Young fringes and object image reconstruction are investigated. It is shown that the interference pattern of two slits formed on the exit surface of the crystal-analyzer (the third plate of the interferometer) is the X-ray interferometric Young fringes. An expression for X-ray interferometric Young fringes period is obtained. The subsequent reconstruction of the slit image as an object is performed by means of Fourier transform of the intensity distribution on the hologram. Three methods of reconstruction of the amplitude transmission complex function of the object are presented: analytical - approximate method, method of iteration and step by step method. As an example the X-ray Fourier interferometric hologram recording and the complex amplitude transmission function reconstruction for a beryllium circular wire are considered

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... Radiology and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  16. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight February is American Heart Month Recently posted: Carotid Intima-Media Thickness Test ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... Abdominal Ultrasound Video: Pelvic Ultrasound Medical Imaging Costs Radiology and You Take our survey Sponsored by Image/ ... Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... exams and use a very small dose of ionizing radiation to produce pictures of the inside of the ... chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  20. Chest X-Ray

    Medline Plus

    Full Text Available ... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  1. Chest X-Ray

    Medline Plus

    Full Text Available ... and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript ... Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You ...

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... chest x-ray is used to evaluate the lungs, heart and chest wall and may be used ... diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A ...

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... and use a very small dose of ionizing radiation to produce pictures of the inside of the ... x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: Carotid Intima-Media Thickness ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  6. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: How to Obtain and ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight March is National Colorectal Cancer Awareness Month Recently posted: Video: The Basketball Game: ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  8. X-Ray Lasers

    Science.gov (United States)

    Eder, David C.

    1998-05-01

    We provide an overview of the status of x-ray laser development worldwide with particular attention given to activities at LLNL. Since the demonstration of x-ray lasing 14 years ago there has been major progress in achieving shorter wavelengths, higher energies per pulse, higher efficiency, shorter pulse durations, etc. Original x-ray lasers used large kJ class lasers to achieve lasing in mid-Z materials with electron collisional pumping in the highly stripped ion being the most successful process for populating the upper-laser state. The two most common electron configurations for these collisional x-ray lasers are Ne-like and Ni-like ions. Through the use of prepulses and short picosecond driving pulses, transient collisional x-ray lasing schemes have been demonstrated using lasers with only a few Joules per pulse. An interesting aspect of these lasers is the time lag in reaching ionization equilibrium helps in obtaining high gain coefficients. A different approach to x-ray lasing is also being studied where lasing occurs in a singly ionized ion following innershell photoionization. The major requirement of the driving laser in this case is an ultrashort pulse duration (rise time to achieve lasing prior to collisional ionization of outershell electrons. In the area of applications, most of the work has been for single pulse experiments such as plasma and biological imaging. However, many of the new x-ray lasers achieve high average power by having a reasonable repetition rate of order 10 Hz and we briefly discuss relevant applications for these x-ray lasers. This work performed under the auspices of US DOE by LLNL under Contract No. W-7405-Eng-48.

  9. X-Ray Optics

    Science.gov (United States)

    1990-01-01

    samples. Another exciting application of microbeam of x-rays is in that of high pressure x-ray diffraction from small samples. Along this line, Yan...will be presented by Jonathan in February at the Physics and Chemistry of Semiconductor Interfaces conference and in March at the American Physical...VUV9 conference this summer. Jeff has also worked on developing software that makes use of the scattering factor tables for both microvax and IBM PC

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  16. Crystallization and preliminary X-ray crystallographic analysis of dihydrouridine synthase from Thermus thermophilus and its complex with tRNA

    International Nuclear Information System (INIS)

    Yu, Futao; Tanaka, Yoshikazu; Yamamoto, Shiho; Nakamura, Akiyoshi; Kita, Shunsuke; Hirano, Nagisa; Tanaka, Isao; Yao, Min

    2011-01-01

    Crystals of dihydrouridine synthase from Thermus thermophilus and its complex with tRNA were obtained and X-ray diffraction data were collected to 1.70 and 3.51 Å resolution, respectively. Dihydrouridine synthase (Dus) is responsible for catalyzing dihydrouridine formation in RNA by the reduction of uridine. To elucidate its RNA-recognition mechanism, Dus from Thermus thermophilus (TthDus) and its complex with tRNA were crystallized. Diffraction data sets were collected from crystals of native and selenomethionine-substituted TthDus to resolutions of 1.70 and 2.30 Å, respectively. These crystals belonged to space group P1. Preliminary X-ray crystallographic analysis showed that two molecules of TthDus were contained in an asymmetric unit. In addition, diffraction data were collected to 3.51 Å resolution from a crystal of selenomethionine-substituted TthDus in complex with tRNA, which belonged to space group P4 1 2 1 2. Preliminary structural analysis showed that the asymmetric unit contained two TthDus–tRNA complexes

  17. Crystallisation and preliminary X-ray diffraction analysis of the protease from Southampton norovirus complexed with a Michael-acceptor inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Coates, Leighton [ORNL; Cooper, Jon [University of Southampton, England; Hussey, Robert [University of Southampton, England

    2008-01-01

    Noroviruses are the predominant cause of human epidemic nonbacterial gastroenteritis. Viral replication requires a cysteine protease that cleaves a 200 kDa viral polyprotein into its constituent functional parts. Here, the crystallization of the recombinant protease from the Southampton norovirus is described. While the native crystals were found to diffract only to medium resolution (2.9 {angstrom}), cocrystals of an inhibitor complex diffracted X-rays to 1.7 {angstrom} resolution. The polypeptide inhibitor (Ac-EFQLQ-propenyl ethyl ester) possesses an amino-acid sequence designed to match the substrate specificity of the enzyme, but was synthesized with a reactive Michael acceptor group at the C-terminal end.

  18. Probing covalency in halogen bonds through donor K-edge X-ray absorption spectroscopy: polyhalides as coordination complexes.

    Science.gov (United States)

    Mustoe, Chantal L; Gunabalasingam, Mathusan; Yu, Darren; Patrick, Brian O; Kennepohl, Pierre

    2017-10-13

    The properties of halogen bonds (XBs) in solid-state I 2 X - and I 4 X - materials (where X = Cl, Br) are explored using donor K-edge X-ray absorption spectroscopy (XAS) to experimentally determine the degree of charge transfer in such XB interactions. The degree of covalency in these bonds is substantial, even in cases where significantly weaker secondary interactions are observed. These data, in concert with previous work in this area, suggests that certain halogen bonds have covalent contributions to bonding that are similar to, and even exceed, those observed in transition metal coordinate bonds. For this reason, we suggest that XB interactions of this type be denoted in a similar way to coordination bonds (X → Y) as opposed to using a representation that is the same as for significantly less covalent hydrogen bonds (XY).

  19. Synthesis, characterization, X-ray crystal structure, DFT calculation, DNA binding, and antimicrobial assays of two new mixed-ligand copper(II) complexes

    Science.gov (United States)

    Ebrahimipour, S. Yousef; Sheikhshoaie, Iran; Mohamadi, Maryam; Suarez, Sebastian; Baggio, Ricardo; Khaleghi, Moj; Torkzadeh-Mahani, Masoud; Mostafavi, Ali

    2015-05-01

    Two new Cu(II) complexes, [Cu(L)(phen)] (1), [Cu(L)(bipy)] (2), where L2- = (3-methoxy-2oxidobenzylidene)benzohydrazidato, phen = 1,10 phenanthroline, and bipy = 2,2‧ bipyridine, were prepared and fully characterized using elemental analyses, FT-IR, molar conductivity, and electronic spectra. The structures of both complexes were also determined by X-ray diffraction. It was found that, both complexes possessed square pyramidal coordination environment in which, Cu(II) ions were coordinated by donor atoms of HL and two nitrogens of heterocyclic bases. Computational studies were performed using DFT calculations at B3LYP/6-311+G(d,p) level of theory. DNA binding activities of these complexes were also investigated using electronic absorption, competitive fluorescence titration and cyclic voltammetry studies. The obtained results indicated that binding of the complexes to DNA was of intercalative mode. Furthermore, antimicrobial activities of these compounds were screened against microorganisms.

  20. X-ray crystallographic characterization of rhesus macaque MHC Mamu-A*02 complexed with an immunodominant SIV-Gag nonapeptide

    International Nuclear Information System (INIS)

    Feng, Youjun; Qi, Jianxun; Zhang, Huimin; Wang, Jinzi; Liu, Jinhua; Jiang, Fan; Gao, Feng

    2005-01-01

    X-ray crystallographic characterization of rhesus macaque MHC Mamu-A*02 complexed with an immunodominant SIV-Gag nonapeptide. Simian immunodeficiency virus (SIV) in the rhesus macaque is regarded as a classic animal model, playing a crucial role in HIV vaccine strategies and therapeutics by characterizing various cytotoxic T-lymphocyte (CTL) responses in macaque monkeys. However, the availability of well documented structural reports focusing on rhesus macaque major histocompatibility complex class I (MHC I) molecules remains extremely limited. Here, a complex of the rhesus macaque MHC I molecule (Mamu-A*02) with human β 2 m and an immunodominant SIV-Gag nonapeptide, GESNLKSLY (GY9), has been crystallized. The crystal diffracts X-rays to 2.7 Å resolution and belongs to space group C2, with unit-cell parameters a = 124.11, b = 110.45, c = 100.06 Å, and contains two molecules in the asymmetric unit. The availability of the structure, which is being solved by molecular replacement, will provide new insights into rhesus macaque MHC I (Mamu-A*02) presenting pathogenic SIV peptides

  1. Ion exchange characteristics of cerium (IV) and Tin(IV) antimonates and their use in rad waste treatment

    International Nuclear Information System (INIS)

    Elnaggar, I.M.; Abdel Hamid, M.M.; Elabsy, M.A.; Aly, H.F.

    1995-01-01

    Cerium (IV) and Tin(IV) antimonates cation exchangers have been synthesized. The products were characterized by powdered X-ray diffraction, thermal analysis and infrared spectrometry. The data of the distribution coefficients showed that the selectivity decreased in the order Eu 3+ >Co 2+ >Sr 2+ >Cs + for both materials. Besides, the drying temperature of the matrices have a profound effect on their ion exchange capacities. Moreover, the obtained results of the effect of gamma radiation on the ion exchange behaviour of the samples showed that a slight decrease of the capacity and the distribution coefficient values with increasing the absorbed dose. 2 figs., 4 tabs

  2. Structure of immune stimulating complex matrices and immune stimulating complexes in suspension determined by small-angle x-ray scattering.

    Science.gov (United States)

    Pedersen, Jan Skov; Oliveira, Cristiano L P; Hübschmann, Henriette Baun; Arleth, Lise; Manniche, Søren; Kirkby, Nicolai; Nielsen, Hanne Mørck

    2012-05-16

    Immune stimulating complex (ISCOM) particles consisting of a mixture of Quil-A, cholesterol, and phospholipids were structurally characterized by small-angle x-ray scattering (SAXS). The ISCOM particles are perforated vesicles of very well-defined structures. We developed and implemented a novel (to our knowledge) modeling method based on Monte Carlo simulation integrations to describe the SAXS data. This approach is similar to the traditional modeling of SAXS data, in which a structure is assumed, the scattering intensity is calculated, and structural parameters are optimized by weighted least-squares methods when the model scattering intensity is fitted to the experimental data. SAXS data from plain ISCOM matrix particles in aqueous suspension, as well as those from complete ISCOMs (i.e., with an antigen (tetanus toxoid) incorporated) can be modeled as a polydisperse distribution of perforated bilayer vesicles with icosahedral, football, or tennis ball structures. The dominating structure is the tennis ball structure, with an outer diameter of 40 nm and with 20 holes 5-6 nm in diameter. The lipid bilayer membrane is 4.6 nm thick, with a low-electron-density, 2.0-nm-thick hydrocarbon core. Surprisingly, in the ISCOMs, the tetanus toxoid is located just below the membrane inside the particles. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  3. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  4. The Electronic Structure of Mn in Oxides, Coordination Complexes, and the Oxygen-Evolving Complex of Photosystem II Studied by Resonant Inelastic X-ray Scattering

    Science.gov (United States)

    Yano, Junko; Visser, Hendrik; Robblee, John H.; Gu, Weiwei; de Groot, Frank M. F.; Christou, George; Pecoraro, Vincent L.

    2014-01-01

    Resonant inelastic X-ray scattering (RIXS) was used to collect Mn K pre-edge spectra and to study the electronic structure in oxides, molecular coordination complexes, as well as the S1 and S2 states of the oxygen-evolving complex (OEC) of photosystem II (PS II). The RIXS data yield two-dimensional plots that can be interpreted along the incident (absorption) energy or the energy transfer axis. The second energy dimension separates the pre-edge (predominantly 1s to 3d transitions) from the main K-edge, and a detailed analysis is thus possible. The 1s2p RIXS final-state electron configuration along the energy transfer axis is identical to conventional L-edge absorption spectroscopy, and the RIXS spectra are therefore sensitive to the Mn spin state. This new technique thus yields information on the electronic structure that is not accessible in conventional K-edge absorption spectroscopy. The line splittings can be understood within a ligand field multiplet model, i.e., (3d,3d) and (2p,3d) two-electron interactions are crucial to describe the spectral shapes in all systems. We propose to explain the shift of the K pre-edge absorption energy upon Mn oxidation in terms of the effective number of 3d electrons (fractional 3d orbital population). The spectral changes in the Mn 1s2p3/2 RIXS spectra between the PS II S1 and S2 states are small compared to that of the oxides and two of the coordination complexes (MnIII(acac)3 and MnIV(sal)2(bipy)). We conclude that the electron in the step from S1 to S2 is transferred from a strongly delocalized orbital. PMID:15303869

  5. Crystallization and preliminary X-ray diffraction analysis of mouse galectin-4 N-terminal carbohydrate recognition domain in complex with lactose

    International Nuclear Information System (INIS)

    Krejčiříková, Veronika; Fábry, Milan; Marková, Vladimíra; Malý, Petr; Řezáčová, Pavlína; Brynda, Jiří

    2008-01-01

    Mouse galectin-4 carbohydrate binding domain was overexpressed in E. coli and crystallized in the presence of lactose. The crystals belong to tetragonal space group P42 1 2 and diffraction data were collected to 2.1 Å resolution. Galectin-4 is thought to play a role in the process of tumour conversion of cells of the alimentary tract and the breast tissue; however, its exact function remains unknown. With the aim of elucidating the structural basis of mouse galectin-4 (mGal-4) binding specificity, we have undertaken X-ray analysis of the N-terminal domain, CRD1, of mGal-4 in complex with lactose (the basic building block of known galectin-4 carbohydrate ligands). Crystals of CRD1 in complex with lactose were obtained using vapour-diffusion techniques. The crystals belong to tetragonal space group P42 1 2 with unit-cell parameters a = 91.1, b = 91.16, c = 57.10 Å and preliminary X-ray diffraction data were collected to 3.2 Å resolution. An optimized crystallization procedure and cryocooling protocol allowed us to extend resolution to 2.1 Å. Structure refinement is currently under way; the initial electron-density maps clearly show non-protein electron density in the vicinity of the carbohydrate binding site, indicating the presence of one lactose molecule. The structure will help to improve understanding of the binding specificity and function of the potential colon cancer marker galectin-4

  6. An X-ray photoelectron spectroscopy and quantum chemical study of copper(II) β-diketonates and Cu(HFA){sub 2} complexes with imidazoline ligands

    Energy Technology Data Exchange (ETDEWEB)

    Kryuchkova, Natalya A., E-mail: knatali@ngs.ru [Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Lavrentyev Av., 3, RU-630090 Novosibirsk (Russian Federation); Novosibirsk State University, Pirogova Street, 2, RU-630090 Novosibirsk (Russian Federation); Stabnikov, Pavel A. [Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Lavrentyev Av., 3, RU-630090 Novosibirsk (Russian Federation); Kalinkin, Alexander V. [Boreskov Institute of Catalysis, Siberian Branch, Russian Academy of Sciences, Lavrentyev Av., 5, RU-630090 Novosibirsk (Russian Federation); Fursova, Elena Yu. [International Tomography Center, Siberian Branch, Russian Academy of Sciences, Institutskaya Street, 3a, RU-630090 Novosibirsk (Russian Federation)

    2016-10-15

    Highlights: • The charge and spin states of Cu(II) β-diketonates and Cu(hfa){sub 2}(imidazoline) are investigated by the XPS and DFT calculations. • The |2p{sup 5}3d{sup 9}> and | 2p{sup 5}3d{sup 10}L> electronic states are asigned to X-ray photoelectron spectra of copper. - Abstract: An X-ray photoelectron spectroscopy study of the charge and spin state of copper(II) β-diketonates and Cu(hfa){sub 2} (hfa–hexafluoroacetylacetonate) complexes with imidazoline ligands is performed with comparison to the data of quantum chemical calculations. It is shown that the structure of the spectra of copper is described by a superposition of the |2p{sup 5}3d{sup 9}> and | 2p{sup 5}3d{sup 10}L> electronic states determined by electron transfer processes between copper and L ligand atoms. It is found that during the coordination of imidazoline ligands to the Cu(hfa){sub 2} complex the spin density is redistributed through the chain of chemical bonds from the ligand nitroxyl group to the copper atom.

  7. Purification, crystallization and preliminary X-ray crystallographic analysis of the ETS domain of human Ergp55 in complex with the cfos promoter DNA sequence

    International Nuclear Information System (INIS)

    Gangwar, Shanti P.; Meena, Sita R.; Saxena, Ajay K.

    2012-01-01

    The ETS domain of human Ergp55 was purified and crystallized in native, complexes with E74, and cfos promoter DNA sequences. The X-ray intensity data set was collected on ETS–cfos promoter DNA complex crystal at 3.1 Å resolution to analyze the structure by molecular replacement technique. The Ergp55 protein belongs to the Ets family of transciption factors. The Ets transcription factors are involved in various developmental processes and the regulation of cancer metabolism. They contain a highly similar DNA-binding domain known as the ETS domain and have diverse functions in oncogenesis and physiology. The Ets transcription factors differ in their DNA-binding preference at the ETS site and the mechanisms by which they target genes are not clearly understood. To understand its DNA-binding mechanism, the ETS domain of Ergp55 was expressed and purified. The ETS domain was crystallized in the native form and in complex forms with DNA sequences from the E74 and cfos promoters. An X-ray diffraction data set was collected from an ETS–cfos DNA complex crystal at a wavelength of 0.9725 Å on the BM14 synchrotron beamline at the ESRF, France. The ETS–cfos DNA complex crystal belonged to space group C222 1 , with four molecules in the asymmetric unit. For structure analysis, initial phases for the ETS–cfos DNA complex were obtained by the molecular-replacement technique with Phaser in the CCP4 suite using the coordinates of Fli-1 protein and cfos DNA as search models. Structure analysis of the ETS–cfos DNA complex may possibly explain the DNA-binding specificity and its mechanism of interaction with the ETS domain of Ergp55

  8. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Setti, G.

    1980-01-01

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  9. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  10. Crystallization and preliminary X-ray diffraction analysis of the complex of Kunitz-type tamarind trypsin inhibitor and porcine pancreatic trypsin

    Science.gov (United States)

    Tomar, Sakshi; Patil, Dipak N.; Datta, Manali; Tapas, Satya; Preeti; Chaudhary, Anshul; Sharma, Ashwani K.; Tomar, Shailly; Kumar, Pravindra

    2009-01-01

    The complex of Tamarindus indica Kunitz-type trypsin inhibitor and porcine trypsin has been crystallized by the sitting-drop vapour-diffusion method using ammonium acetate as precipitant and sodium acetate as buffer. The homogeneity of complex formation was checked by size-exclusion chromatography and further confirmed by reducing SDS–PAGE. The crystals diffracted to 2.0 Å resolution and belonged to the tetragonal space group P41, with unit-cell parameters a = b = 57.1, c = 120.1 Å. Preliminary X-ray diffraction analysis indicated the presence of one unit of inhibitor–trypsin complex per asymmetric unit, with a solvent content of 45%. PMID:19923745

  11. Crystallization and preliminary X-ray analysis of a U2AF65 variant in complex with a polypyrimidine-tract analogue by use of protein engineering

    International Nuclear Information System (INIS)

    Sickmier, E. Allen; Frato, Katherine E.; Kielkopf, Clara L.

    2006-01-01

    A complex of the essential splicing factor U2AF 65 and a deoxyuridine oligonucleotide has been crystallized by modification of an interdomain linker. The large subunit of the essential pre-mRNA splicing factor U2 auxiliary factor (U2AF 65 ) binds the polypyrimidine tract near the 3′ splice site of pre-mRNA introns and directs the association of the U2 small nuclear ribonucleoprotein particle (U2 snRNP) of the spliceosome with the pre-mRNA. Protein engineering, in which the flexible linker region connecting tandem RNA-recognition motifs (RRMs) within the U2AF 65 RNA-binding domain was partially deleted, allowed successful crystallization of the protein–nucleic acid complex. Cocrystals of a U2AF 65 variant with a deoxyuridine dodecamer diffract X-rays to 2.9 Å resolution and contain one complex per asymmetric unit

  12. Assignment of Pre-Edge Features in the Ru K-Edge X-Ray Absorption Spectra of Organometallic Ruthenium Complexes

    Energy Technology Data Exchange (ETDEWEB)

    Getty, K.; Delgado-Jaime, M.U.; Kennepohl, P.

    2009-05-18

    The nature of the lowest energy bound-state transition in the Ru K-edge X-ray absorption spectra for a series of Grubbs-type ruthenium complexes was investigated. The pre-edge feature was unambiguously assigned as resulting from formally electric dipole forbidden Ru 4d {l_arrow} 1s transitions. The intensities of these transitions are extremely sensitive to the ligand environment and the symmetry of the metal centre. In centrosymmetric complexes the pre-edge is very weak since it is limited by the weak electric quadrupole intensity mechanism. By contrast, upon breaking centrosymmetry, Ru 5p-4d mixing allows for introduction of electric dipole allowed character resulting in a dramatic increase in the pre-edge intensity. The information content of this approach is explored as it relates to complexes of importance in olefin metathesis and its relevance as a tool for the study of reactive intermediates.

  13. Use of X-Ray Absorption Spectra as a ``Fingerprint'' of the Local Environment in Complex Chalcogenides

    Science.gov (United States)

    Branci, C.; Womes, M.; Lippens, P. E.; Olivier-Fourcade, J.; Jumas, J. C.

    2000-03-01

    The local environment of tin, titanium, iron, and sulfur in spinel compounds Cu2FeSn3S8 and Cu2FeTi3S8 was studied by X-ray absorption spectroscopy (XAS) at the titanium, iron, sulfur K edges, and the tin LI-edge. As detailed calculations of the electronic structure of these compounds are difficult to carry out due to the large number of atoms contained in the unit cell, the XAS spectra of the spinels are compared to those of relatively simple binary sulfides like SnS2, TiS2, and FeS. Indeed, the metal environments in these binary compounds are very similar to those in the spinels, and they can be considered good model compounds allowing the interpretation of electronic transitions observed in the spectra of quaternary phases. In the latter, the bottom of the conduction band is mainly formed by Sn 5s-S 3p, Sn 5p-S 3p antibonding states for the tin-based compounds and by Ti 3dt2g-S 3p, Ti 3deg-S 3p antibonding states for the titanium-based compounds. It it shown that the local environment of iron atoms remains unchanged when substituting tin with titanium atoms, according to a topotactic substitution.

  14. High resolution X-ray structures of mouse major urinary protein nasal isoform in complex with pheromones

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Miller, Samantha; Zou, Qin; Novotny, Milos V.; Hurley, Thomas D. (Indiana-Med); (Indiana)

    2010-09-07

    In mice, the major urinary proteins (MUP) play a key role in pheromonal communication by binding and transporting semiochemicals. MUP-IV is the only isoform known to be expressed in the vomeronasal mucosa. In comparison with the MUP isoforms that are abundantly excreted in the urine, MUP-IV is highly specific for the male mouse pheromone 2-sec-butyl-4,5-dihydrothiazole (SBT). To examine the structural basis of this ligand preference, we determined the X-ray crystal structure of MUP-IV bound to three mouse pheromones: SBT, 2,5-dimethylpyrazine, and 2-heptanone. We also obtained the structure of MUP-IV with 2-ethylhexanol bound in the cavity. These four structures show that relative to the major excreted MUP isoforms, three amino acid substitutions within the binding calyx impact ligand coordination. The F103 for A along with F54 for L result in a smaller cavity, potentially creating a more closely packed environment for the ligand. The E118 for G substitution introduces a charged group into a hydrophobic environment. The sidechain of E118 is observed to hydrogen bond to polar groups on all four ligands with nearly the same geometry as seen for the water-mediated hydrogen bond network in the MUP-I and MUP-II crystal structures. These differences in cavity size and interactions between the protein and ligand are likely to contribute to the observed specificity of MUP-IV.

  15. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  16. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  17. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  18. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  19. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  20. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  1. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  2. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  3. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  4. Flash x-ray

    International Nuclear Information System (INIS)

    Johnson, Q.; Pellinen, D.

    1976-01-01

    The complementary techniques of flash x-ray radiography (FXR) and flash x-ray diffraction (FXD) provide access to a unique domain in nondestructive materials testing. FXR is useful in studies of macroscopic properties during extremely short time intervals, and FXD, the newer technique, is used in studies of microscopic properties. Although these techniques are similar in many respects, there are some substantial differences. FXD generally requires low-voltage, line-radiation sources and extremely accurate timing; FXR is usually less demanding. Phenomena which can be profitably studied by FXR often can also be studied by FXD to permit a complete materials characterization

  5. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  6. CRL X-RAY TUBE

    OpenAIRE

    Kolchevsky, N. N.; Petrov, P. V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed.

  7. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  8. Crystallization and preliminary X-ray crystallographic studies of a Lys49-phospholipase A2 homologue from Bothrops pirajai venom complexed with rosmarinic acid

    International Nuclear Information System (INIS)

    Santos, Juliana I. dos; Santos-Filho, Norival A.; Soares, Andreimar M.; Fontes, Marcos R. M.

    2010-01-01

    PrTX-I, a noncatalytic and myotoxic Lys49-phospholipase A 2 from B. pirajai venom, was cocrystallized with the inhibitor rosmarinic acid from C. verbenacea. The crystals diffracted X-rays to 1.8 Å resolution and the structure was solved, indicating a remarkable electronic density for the ligand at the entrance to the hydrophobic channel. PrTX-I, a noncatalytic and myotoxic Lys49-phospholipase A 2 from Bothrops pirajai venom, was crystallized in the presence of the inhibitor rosmarinic acid (RA). This is the active compound in the methanolic extract of Cordia verbenacea, a plant that is largely used in Brazilian folk medicine. The crystals diffracted X-rays to 1.8 Å resolution and the structure was solved by molecular-replacement techniques, showing electron density that corresponds to RA molecules at the entrance to the hydrophobic channel. The crystals belong to space group P2 1 2 1 2 1 , indicating conformational changes in the structure after ligand binding: the crystals of all apo Lys49-phospholipase A 2 structures belong to space group P3 1 21, while the crystals of complexed structures belong to space groups P2 1 or P2 1 2 1 2 1

  9. X-ray fluorescence investigation of heavy-metal contamination on metal surfaces in the Pilot Plant Complex, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, K.L.; Draugelis, A.K.; Schneider, J.F.; Billmark, K.A.; Zimmerman, R.E.

    1995-07-01

    A field program using a portable x-ray fluorescence (XRF) instrument was carried out to obtain data on loadings of RCRA-regulated heavy metals in paint on metal surfaces within the Pilot Plant Complex at Aberdeen Proving Ground, Maryland. Measured loadings of heavy metals were sufficiently small that they do not present problems for either human exposure or the disposition of building demolition rubble. An attempt to develop an external calibration of the XRF instrument for cadmium, chromium, and lead was unsuccessful. Significant substrate effects were observed for cadmium and chromium; for accurate results for these elements, it appears necessary to calibrate by using a sample of the actual metal substrate on which the paint is located. No substrate effects were observed for lead, but the use of lead L-shell x-ray emission lines in the instrument mode utilized in this study appears to result in a significant underestimate of the lead loading due to self-absorption of these emissions.

  10. X-ray diagnostics in non-specialized conditions

    International Nuclear Information System (INIS)

    Vasil’yev, A Y; Lyubimenko, V A; Potrakhov, Y N; Potrakhov, N N; Bessonov, V B; Klonov, V V; Larionov, I A; Gryaznov, A Y; Zhamova, K K

    2017-01-01

    The results of research in the development of X-ray diagnostic equipment in non-specialized conditions are described. The design of the first domestic digital X-ray diagnostic complex for neonatology in portable design is presented. Examples of X-ray images obtained “at home” from a patient are given. (paper)

  11. Synthesis, characterization, single crystal X-ray determination, fluorescence and electrochemical studies of new dinuclear nickel(II) and oxovanadium(IV) complexes containing double Schiff base ligands.

    Science.gov (United States)

    Shafaatian, Bita; Ozbakzaei, Zahra; Notash, Behrouz; Rezvani, S Ahmad

    2015-04-05

    A series of new bimetallic complexes of nickel(II) and vanadium(IV) have been synthesized by the reaction of the new double bidentate Schiff base ligands with nickel acetate and vanadyl acetylacetonate in 1:1 M ratio. In nickel and also vanadyl complexes the ligands were coordinated to the metals via the imine N and enolic O atoms. The complexes have been found to possess 1:1 metals to ligands stoichiometry and the molar conductance data revealed that the metal complexes were non-electrolytes. The nickel and vanadyl complexes exhibited distorted square planar and square pyramidal coordination geometries, respectively. The emission spectra of the ligands and their complexes were studied in methanol. Electrochemical properties of the ligands and their metal complexes were also investigated in DMSO solvent at 150 mV s(-1) scan rate. The ligands and metal complexes showed both quasi-reversible and irreversible processes at this scan rate. The Schiff bases and their complexes have been characterized by FT-IR, 1H NMR, UV/Vis spectroscopies, elemental analysis and conductometry. The crystal structure of the nickel complex has been determined by single crystal X-ray diffraction. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  13. Synthesis, characterization and single crystal x-ray analysis of a complex of iron(II) bis(2,4-dimethylphenyl)dithiophosphate with 4-ethylpyridine

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sandeep; Andotra, Savit; Kaur, Mandeep [University of Jammu, Department of Chemistry (India); Gupta, Vivek K.; Kant, Rajni [Department of Physics and Electronics, University of Jammu, X-ray Crystallographic Laboratory (India); Pandey, Sushil K., E-mail: kpsushil@rediffmail.com [University of Jammu, Department of Chemistry (India)

    2016-09-15

    Complex of iron(II) bis(2,4-dimethylphenyl)dithiophosphate with 4-ethylpyridine [((2,4- (CH{sub 3}){sub 2}C{sub 6}H{sub 3}O)2PS2)2Fe(NC{sub 5}H{sub 4}(C{sub 2}H{sub 5})-4){sub 2}] is synthesized and characterized by elemental analysis, magnetic moment, IR spectroscopy and single crystal X-ray analysis. Complex crystallizes in the monoclinic sp. gr. P2{sub 1}/n, Z = 2. Crystal structure consists of mononuclear units with Fe(II) ion chelated by four S atoms of the two diphenyldithiophosphate ligands in bidentate manner. N atoms from two 4-ethylpyridine ligands are axially coordinated to the Fe(II) atom leading to an octahedral geometry.

  14. Second-sphere coordination complex via hydrogen bonding: Synthesis, characterization, X-ray crystal structure determination and packing of hexaamminecobalt(III) chloride di( para-nitrobenzoate)

    Science.gov (United States)

    Sharma, Raj Pal; Bala, Ritu; Sharma, Rajni; Perez, Julio; Miguel, Daniel

    2006-09-01

    A reddish orange coloured crystalline solid of hexaamminecobalt(III) chloride di( para-nitrobenzoate) was obtained when hexaamminecobalt(III) chloride was reacted with the sodium salt of para-nitrobenzoic acid (1:3 molar ratio) in hot aqueous medium. This cobalt(III) complex salt has been characterized by elemental analyses and spectroscopic techniques (e.g. UV/visible, IR and NMR). Single-crystal X-ray structure determination of the title complex salt revealed that it contains the cationic cobaltammine ([Co(NH 3) 6] 3+) and mixed anions (Cl -, NO 2C 6H 4COO -), which are held together by electrostatic forces attractions through second-sphere coordination, i.e. N-H⋯O (carboxylate and nitro) and N-H⋯Cl hydrogen bonds, resulting in a three-dimensional network.

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... to consider the likelihood of benefit to your health. While a chest x-ray use a tiny ...

  16. X-ray and neutron small-angle scattering analysis of the complex formed by the Met receptor and the Listeria monocytogenes invasion protein InlB.

    Science.gov (United States)

    Niemann, Hartmut H; Petoukhov, Maxim V; Härtlein, Michael; Moulin, Martine; Gherardi, Ermanno; Timmins, Peter; Heinz, Dirk W; Svergun, Dmitri I

    2008-03-21

    The Listeria monocytogenes surface protein InlB binds to the extracellular domain of the human receptor tyrosine kinase Met, the product of the c-met proto-oncogene. InlB binding activates the Met receptor, leading to uptake of Listeria into normally nonphagocytic host cells. The N-terminal half of InlB (InlB(321)) is sufficient for Met binding and activation. The complex between this Met-binding domain of InlB and various constructs of the Met ectodomain was characterized by size exclusion chromatography and dynamic light scattering, and structural models were built using small-angle X-ray scattering and small-angle neutron scattering. Although most receptor tyrosine kinase ligands induce receptor dimerization, InlB(321) consistently binds the Met ectodomain with a 1:1 stoichiometry. A construct comprising the Sema and PSI domains of Met, although sufficient to bind the physiological Met ligand hepatocyte growth factor/scatter factor, does not form a complex with InlB(321) in solution, highlighting the importance of Met Ig domains for InlB binding. Small-angle X-ray scattering and small-angle neutron scattering measurements of ligand and receptor, both free and in complex, reveal an elongated shape for the receptor. The four Ig domains form a bent, rather than a fully extended, conformation, and InlB(321) binds to Sema and the first Ig domain of Met, in agreement with the recent crystal structure of a smaller Met fragment in complex with InlB(321). These results call into question whether receptor dimerization is the basic underlying event in InlB(321)-mediated Met activation and demonstrate differences in the mechanisms by which the physiological ligand hepatocyte growth factor/scatter factor and InlB(321) bind and activate the Met receptor.

  17. A small-angle X-ray scattering study of complexes formed in mixtures of a cationic polyelectrolyte and an anionic surfactant

    DEFF Research Database (Denmark)

    Bergström, M.; Kjellin, U.R.M.; Claesson, P.M.

    2002-01-01

    The internal structure of the solid phase formed in mixtures of the anionic surfactant sodium dodecyl sulfate (SDS) and a range of oppositely charged polyelectrolytes with different side chains and charge density has been investigated using small-angle X-ray scattering. Polyelectrolytes with short....... The hexagonal structure of MAPTAC is retained either when a neutral monomer (acrylamide, AM) is included in the polymer backbone to reduce the charge density or when a nonionic surfactant is admixed to the SDS/polyelctrolyte complex.. The unit cell length of AM-MAPTAC increases with decreasing charge density...... structure and the bilayers in the lamellar structure are based on self-assembled surfactant aggregates with the polyelectrolyte mainly located in the aqueous region adjacent to the charged surfactant headgroups....

  18. The complex between SOS3 and SOS2 regulatory domain from Arabidopsis thaliana: cloning, expression, purification, crystallization and preliminary X-ray analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sánchez-Barrena, María José; Moreno-Pérez, Sandra; Angulo, Iván; Martínez-Ripoll, Martín; Albert, Armando, E-mail: xalbert@iqfr.csic.es [Grupo de Cristalografía Macromolecular y Biología Estructural, Instituto de Química Física ‘Rocasolano’, Consejo Superior de Investigaciones Científicas, Serrano 119, E-28006 Madrid (Spain)

    2007-07-01

    Recombinant SOS3 and SOS2 regulatory domain from A. thaliana have been coexpressed in E. coli, purified and crystallized by the hanging-drop vapour-diffusion method. An X-ray data set has been collected at 2.0 Å resolution. The salt-tolerance genes SOS3 (salt overly sensitive 3) and SOS2 (salt overly sensitive 2) regulatory domain of Arabidopsis thaliana were cloned into a polycistronic plasmid and the protein complex was expressed in Escherichia coli, allowing purification to homogeneity in three chromatographic steps. Crystals were grown using vapour-diffusion techniques. The crystals belonged to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 44.14, b = 57.39, c = 141.90 Å.

  19. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  20. Copper(II) cyanido-bridged bimetallic nitroprusside-based complexes: Syntheses, X-ray structures, magnetic properties, 57Fe Moessbauer spectroscopy and thermal studies

    International Nuclear Information System (INIS)

    Travnicek, Zdenek; Herchel, Radovan; Mikulik, Jiri; Zboril, Radek

    2010-01-01

    Three heterobimetallic cyanido-bridged copper(II) nitroprusside-based complexes of the compositions [Cu(tet)Fe(CN) 5 NO].H 2 O (1), where tet=N,N'-bis(3-aminopropyl)ethylenediamine, [Cu(hto)Fe(CN) 5 NO].2H 2 O (2), where hto=1,3,6,9,11,14-hexaazatricyclo[12.2.1.1 6,9 ]octadecane and [Cu(nme) 2 Fe(CN) 5 NO].H 2 O (3), where nme=N-methylethylenediamine, were synthesized and characterized by elemental analyses, 57 Fe Moessbauer and FTIR spectroscopies, thermal analysis, magnetic measurements and single-crystal X-ray analysis. The products of thermal degradation processes of 2 and 3 were studied by XRD, 57 Fe Moessbauer spectroscopy, SEM and EDS, and they were identified as mixtures of CuFe 2 O 4 and CuO. - Three heterobimetallic cyano-bridged copper(II) nitroprusside-based complexes of the general compositions of [Cu(L)Fe(CN) 5 NO].xH 2 O, where L=N,N'-bis(3-aminopropyl)ethylenediamine (complex 1), 1,3,6,9,11,14-hexaazatricyclo[12.2.1.1 6,9 ]-octadecane (complex 2) and N-methylethylenediamine (complex 3), were synthesized, and fully structurally and magnetically characterized. SEM, EDS, XRD and 57 Fe Moessbauer experiments were used for characterization of thermal decomposition products of complexes 2 and 3.

  1. X-ray refractometer

    International Nuclear Information System (INIS)

    Tur'yanskij, A.G.; Pirshin, I.V.

    2001-01-01

    Paper introduces a new circuit of X-ray refractometer to study angular and spectral features of refracted radiation within hard X-ray range. Refractometer incorporates two goniometers, two crystal-analyzers and three radiation detectors. The maximum distance between radiation source focal point and a receiving slit of the second goniometer is equal to 1.4 m. For the first time one obtained refraction patterns of fine-film specimens including C/Si stressed structure. Paper describes a new technique of refractometry via specimen oscillation at fixed position of a detecting device. Paper presents the measurement results of oscillation refraction patterns for specimens of melted quartz and ZnSe single crystal [ru

  2. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  3. X-ray Ordinance

    International Nuclear Information System (INIS)

    Kramer, R.; Zerlett, G.

    1983-01-01

    This commentary, presented as volume 2 of the Deutsches Strahlenschutzrecht (German legislation on radiation protection) deals with the legal provisions of the ordinance on the protection against harmful effects of X-radiation (X-ray Ordinance - RoeV), of March 1, 1973 (announced in BGBl.I, page 173), as amended by the ordinance on the protection against harmful effects of ionizing radiation, of October 13, 1976 (announced in BGBl. I, page 2905). Thus volume 2 completes the task started with volume 1, namely to present a comprehensive view and account of the body of laws governing radiation protection, a task which was thought useful as developments in the FRG led to regulations being split up into the X-ray Ordinance, and the Radiation Protection Ordinance. In order to present a well-balanced commentary on the X-ray Ordinance, it was necessary to discuss the provisions both from the legal and the medical point of view. This edition takes into account the Fourth Public Notice of the BMA (Fed. Min. of Labour and Social Affairs) concerning the implementation of the X-ray Ordinance of January 4, 1982, as well as court decisions and literature published in this field, until September 1982. In addition, the judgment of the Federal Constitutional Court, dated October 19, 1982, concerning the voidness of the law on government liability, and two decisions by the Federal High Court, dated November 23, 1982, concerning the right to have insight into medical reports - of great significance in practice - have been considered. This commentary therefore is up to date with current developments. (orig.) [de

  4. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  5. Synthesis and X-ray diffraction study of some nickel(II) complexes of urea and thiourea

    International Nuclear Information System (INIS)

    Sharma, Pradeep; Bhale, Jaishree; Mishra, Ashutosh; Malviya, Pramod

    2014-01-01

    XRD of four biologically important nickel(II) complexes having urea and thiourea as primary ligands and sulphate and nitrate as secondary ligands have been studied using Bruker D8 Advance diffractometer at IUC, Indore. The synthesized metal complexes were characterized by XRD measurements in order to elucidate their geometry. The data obtained has been preceded using XRD data analysis program Origin 6.0 Professional. From the experimental measurements, various parameters, e.g., particle size, lattice parameter have been estimated.Particle size for Ni-urea complexes is found in the range of 4.23-9.01 nm while for Ni-thiourea complexes its range is 0.26-9.76 nm.Lattice parameter for all these complexes is found in the range of 7.47-8.06 Å. The XRD analysis revealed the crystalline nature of all the complexes.

  6. Producing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Jung, R.G.; Applebaum, D.C.; Fairand, B.P.; Gallagher, W.J.

    1977-01-01

    A method of producing x-rays by directing radiant energy from a laser onto a target is described. Conversion efficiency of at least about 3 percent is obtained by providing the radiant energy in a low-power precursor pulse of approximately uniform effective intensity focused onto the surface of the target for about 1 to 30 nanoseconds so as to generate an expanding unconfined coronal plasma having less than normal solid density throughout and comprising a low-density (underdense) region wherein the plasma frequency is less than the laser radiation frequency and a higher-density (overdense) region wherein the plasma frequency is greater than the laser radiation frequency and, about 1 to 30 nanoseconds after the precursor pulse strikes the target, a higher-power main pulse focused onto the plasma for about 10 -3 to 30 nanoseconds and having such power density and total energy that the radiant energy is absorbed in the underdense region and conducted into the overdense region to heat it and thus to produce x-rays therefrom with the plasma remaining substantially below normal solid density and thus facilitating the substantial emission of x-rays in the form of spectral lines arising from nonequilibrium ionization states

  7. Isolation and X-ray characterization of palladium–N complexes in the guanylation of aromatic amines. Mechanistic implications

    Directory of Open Access Journals (Sweden)

    Abdessamad Grirrane

    2013-07-01

    Full Text Available In the context of palladium-catalyzed guanylation of anilines herein, we have been able to characterize and isolate bis(anilino and bis(guanidinoPd(II complexes using reaction conditions under which stoichiometric amounts of palladium salts are used. Characterization of these palladium complexes strongly supports a mechanistic proposal for the catalytic guanylation of anilines using PdCl2(NCCH32 as catalyst that involves the intermediacy of these Pd(II complexes.

  8. X-ray structure characterization of palladium(II) ternary complexes of pyridinedicarboxylic and phthalic acid with phenanthroline and bipyridine.

    Science.gov (United States)

    Wang, Yue; Okabe, Nobuo

    2005-04-01

    The crystal structures of the series of four ternary complexes, [Pd(phen)(2,6-PDCA)].4H(2)O (1) (phen=1,10-phenanthroline; 2,6-PDCA=2,6-pyridinedicarboxylic acid), [Pd(bpy)(2,3-PDCA)].3H(2)O (2) (bpy=2,2'-bipyridineand; 2,3-PDCA=2,3-pyridinedicarboxylic acid) and [Pd(phen)(PHT)].2.5H(2)O (3) (PHT=o-phthalic acid ) and [Pd(bpy)(PHT)].1.5H(2)O (4), are determined and the coordination modes of palladium(II) ternary complexes are characterized. All complexes take the mononuclear Pd(II) complexes, in which central Pd(II) atom of each complex has a similar distorted square-planar four coordination geometry. In all complexes, the aromatic heterocyclic compounds, phen and bpy, behave as a bidentate N, N' ligand. In the complex 1 and 2, 2,6-PDCA and 2,3-PDCA behave as a bidentate N, O ligand, and in complex 3 and 4, PHT behaves as a bidentate O, O' ligand.

  9. Synthesis, characterization, microbiological evaluation, genotoxicity and synergism tests of new nano silver complexes with sulfamoxole: X-ray diffraction of [Ag2(SMX)2]·DMSO.

    Science.gov (United States)

    Velluti, Francesca; Mosconi, Natalia; Acevedo, Ana; Borthagaray, Graciela; Castiglioni, Jorge; Faccio, Ricardo; Back, Davi Fernando; Moyna, Guillermo; Rizzotto, Marcela; Torre, María H

    2014-12-01

    The synthesis and microbiological evaluation of two new Ag(I) complexes with sulfamoxole (SMX), [Ag2(SMX)2]·H2O and [Ag4(SCN)3(SMX)]·H2O are described. Both were characterized by elemental analysis, thermogravimetry, powder and single crystal X-ray diffraction, NMR, Raman and experimental and theoretical IR spectroscopies. Their antibacterial and antifungal properties were evaluated by agar and broth dilution assays, respectively. In addition, synergism tests for Pseudomonas aeruginosa were performed, and genotoxicity studies were carried out employing the Allium cepa test. Both complexes displayed good activity against Escherichia coli, Staphylococcus aureus, P. aeruginosa, and 10 fungi strains, with lower minimum inhibitory concentrations (MICs) than that of free SMX in all cases. The nanometrical crystallite particle size determined from XRPD, DLS and TEM might explain the good microbiological activity in spite of the low solubility of both complexes. The fractional inhibitory concentration (FIC) calculated from the P. aeruginosa test data indicated that the activity of the complexes is not due to synergism of the free components in the concentration ratios studied. Moreover, none of the complexes displayed cytotoxic effects on onions in the concentration range tested, and chromosome aberrations were not observed. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x- ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... shades of gray and air appears black. Until recently, x-ray images were maintained on large film ... assist you in finding the most comfortable position possible that still ensures x-ray image quality. top ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  18. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... image on photographic film or a special detector. Different parts of the body absorb the x-rays ... process is repeated. Two or three images (from different angles) will typically be taken. An x-ray ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... up in shades of gray and air appears black. Until recently, x-ray images were maintained on ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissues around or in bones. top of page How should I prepare? Most bone x-rays require ... is placed beneath the patient. top of page How does the procedure work? X-rays are a ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and ...

  6. Soft X-ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seely, John

    1999-05-20

    The contents of this report cover the following: (1) design of the soft x-ray telescope; (2) fabrication and characterization of the soft x-ray telescope; and (3) experimental implementation at the OMEGA laser facility.

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray technologist if there is any possibility that they are pregnant. Many imaging tests are not performed during pregnancy ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  9. High Resolution X-ray Diffraction Dataset for Bacillus licheniformis Gamma Glutamyl Transpeptidase-acivicin complex: SUMO-Tag Renders High Expression and Solubility.

    Science.gov (United States)

    Kumari, Shobha; Pal, Ravi Kant; Gupta, Rani; Goel, Manisha

    2017-02-01

    Gamma glutamyl transpeptidase, (GGT) is a ubiquitous protein which plays a central role in glutathione metabolism and has myriad clinical implications. It has been shown to be a virulence factor for pathogenic bacteria, inhibition of which results in reduced colonization potential. However, existing inhibitors are effective but toxic and therefore search is on for novel inhibitors, which makes it imperative to understand the interactions of various inhibitors with the protein in substantial detail. High resolution structures of protein bound to different inhibitors can serve this purpose. Gamma glutamyl transpeptidase from Bacillus licheniformis is one of the model systems that have been used to understand the structure-function correlation of the protein. The structures of the native protein (PDB code 4OTT), of its complex with glutamate (PDB code 4OTU) and that of its precursor mimic (PDB code 4Y23) are available, although at moderate/low resolution. In the present study, we are reporting the preliminary analysis of, high resolution X-ray diffraction data collected for the co-crystals of B. licheniformis, Gamma glutamyl transpeptidase, with its inhibitor, Acivicin. Crystals belong to the orthorhombic space group P2 1 2 1 2 1 and diffract X-ray to 1.45 Å resolution. This is the highest resolution data reported for all GGT structures available till now. The use of SUMO fused expression system enhanced yield of the target protein in the soluble fraction, facilitating recovery of protein with high purity. The preliminary analysis of this data set shows clear density for the inhibitor, acivicin, in the protein active site.

  10. Development of X-ray excitable luminescent probes for scanning X-ray microscopy

    International Nuclear Information System (INIS)

    Moronne, M.M.

    1999-01-01

    Transmission soft X-ray microscopy is now capable of achieving resolutions that are typically 5 times better than the best-visible light microscopes. With expected improvements in zone plate optics, an additional factor of two may be realized within the next few years. Despite the high resolution now available with X-ray microscopes and the high X-ray contrast provided by biological molecules in the soft X-ray region (λ=2-5 nm), molecular probes for localizing specific biological targets have been lacking. To circumvent this problem, X-ray excitable molecular probes are needed that can target unique biological features. In this paper we report our initial results on the development of lanthanide-based fluorescent probes for biological labeling. Using scanning luminescence X-ray microscopy (SLXM, Jacobsen et al., J. Microscopy 172 (1993) 121-129), we show that lanthanide organo-polychelate complexes are sufficiently bright and radiation resistant to be the basis of a new class of X-ray excitable molecular probes capable of providing at least a fivefold improvement in resolution over visible light microscopy. Lanthanide probes, able to bind 80-100 metal ions per molecule, were found to give strong luminescent signals with X-ray doses exceeding 10 8 Gy, and were used to label actin stress fibers and in vitro preparations of polymerized tubulin. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  11. Development of X-ray Computed Tomography (CT) Imaging Method for the Measurement of Complex 3D Ice Shapes Project

    Data.gov (United States)

    National Aeronautics and Space Administration — When ice accretes on a wing or other aerodynamic surface, it can produce extremely complex shapes. These are comprised of well-known shapes such as horns and...

  12. Synthesis, spectroscopic and single crystal X-ray studies on three new mononuclear Ni(II) pincer type complexes: DFT calculations and their antimicrobial activities

    Science.gov (United States)

    Layek, Samaresh; Agrahari, Bhumika; Tarafdar, Abhrajyoti; Kumari, Chanda; Anuradha; Ganguly, Rakesh; Pathak, Devendra D.

    2017-08-01

    Three new mononuclear square planar Ni(II) complexes, containing pincer type tridentate Schiff base ligands, having general formula [(NiL1(4-MePy)] (1), [(NiL1(2-AzNp)] (2), and [(NiL2(4-MePy)] (3) [where L1 = anion of N-(2-hydroxy-3-methoxybenzylidene) benzoylhydrazide (HL1), L2 = anion of N-(2-hydroxy-3-methoxybenzylidene) thiosemicarbazide (HL2), 4-MePy = 4-Methylpyridine and 2-AzNp = 2-Azanapthalene] have been synthesized and fully characterized by FT-IR, UV-visible, NMR, single crystal X-ray diffraction studies and elemental analysis. All the three complexes show square planar geometry around the nickel atom. The pincer type ligand occupies three coordination sites, while the fourth site is occupied by the monodentate nitrogen containing ligand. The Quantum chemical DFT calculations have also been carried out using DFT/B3LYP method and 6-311++G(d,p) basis set. The synthesized nickel complexes were screened for antimicrobial activities by agar well diffusion method against E. coli bacteria. Out of three complexes, [(NiL2(4-MePy)] (3) only showed the antimicrobial activity against E. coli bacteria.

  13. Crystallization and preliminary X-ray diffraction analysis of the Cmr2–Cmr3 subcomplex in the CRISPR–Cas RNA-silencing effector complex

    International Nuclear Information System (INIS)

    Osawa, Takuo; Inanaga, Hideko; Numata, Tomoyuki

    2013-01-01

    The Cmr2–Cmr3 subcomplex from P. furiosus was co-crystallized with 3′-AMP. X-ray diffraction data for the crystals were collected to 2.6 Å resolution using a synchrotron-radiation source. Clustered, regularly interspaced, short palindromic repeat (CRISPR) loci, found in prokaryotes, are transcribed to produce CRISPR RNAs (crRNAs). The Cmr proteins (Cmr1–6) and crRNA form a ribonucleoprotein complex that degrades target RNAs derived from invading genetic elements. Cmr2dHD, a Cmr2 variant lacking the N-terminal putative HD nuclease domain, and Cmr3 were co-expressed in Escherichia coli cells and co-purified as a complex. The Cmr2dHD–Cmr3 complex was co-crystallized with 3′-AMP by the vapour-diffusion method. The crystals diffracted to 2.6 Å resolution using synchrotron radiation at the Photon Factory. The crystals belonged to the orthorhombic space group I222, with unit-cell parameters a = 103.9, b = 136.7, c = 192.0 Å. The asymmetric unit of the crystals is expected to contain one Cmr2dHD–Cmr3 complex with a Matthews coefficient of 3.0 Å 3 Da −1 and a solvent content of 59%

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... used for bone x-rays consists of an x-ray tube suspended over a table on which the patient ... a hospital bed or the emergency room. The x-ray tube is connected to a flexible arm that is ...

  15. X-ray Crystallography Facility

    Science.gov (United States)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-rays. top of page What does the equipment look like? The equipment typically used for bone x-rays consists of ... and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely available in emergency ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  18. Tunable X-ray source

    Science.gov (United States)

    Boyce, James R [Williamsburg, VA

    2011-02-08

    A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

  19. X-Ray Exam: Ankle

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What It Is Why ... You Have Questions Print What It Is An ankle X-ray is a safe and painless test ...

  20. Crystallization and preliminary X-ray diffraction analysis of the CRISPR-Cas RNA-silencing Cmr complex.

    Science.gov (United States)

    Osawa, Takuo; Inanaga, Hideko; Numata, Tomoyuki

    2015-06-01

    Clustered regularly interspaced short palindromic repeat (CRISPR)-derived RNA (crRNA) and CRISPR-associated (Cas) proteins constitute a prokaryotic adaptive immune system (CRISPR-Cas system) that targets and degrades invading genetic elements. The type III-B CRISPR-Cas Cmr complex, composed of the six Cas proteins (Cmr1-Cmr6) and a crRNA, captures and cleaves RNA complementary to the crRNA guide sequence. Here, a Cmr1-deficient functional Cmr (CmrΔ1) complex composed of Pyrococcus furiosus Cmr2-Cmr3, Archaeoglobus fulgidus Cmr4-Cmr5-Cmr6 and the 39-mer P. furiosus 7.01-crRNA was prepared. The CmrΔ1 complex was cocrystallized with single-stranded DNA (ssDNA) complementary to the crRNA guide by the vapour-diffusion method. The crystals diffracted to 2.1 Å resolution using synchrotron radiation at the Photon Factory. The crystals belonged to the triclinic space group P1, with unit-cell parameters a = 75.5, b = 76.2, c = 139.2 Å, α = 90.3, β = 104.8, γ = 118.6°. The asymmetric unit of the crystals is expected to contain one CmrΔ1-ssDNA complex, with a Matthews coefficient of 2.03 Å(3) Da(-1) and a solvent content of 39.5%.

  1. Structural investigation of oxovanadium(IV) Schiff base complexes: X-ray crystallography, electrochemistry and kinetic of thermal decomposition

    Czech Academy of Sciences Publication Activity Database

    Asadi, M.; Asadi, Z.; Savaripoor, N.; Dušek, Michal; Eigner, Václav; Shorkaei, M.R.; Sedaghat, M.

    2015-01-01

    Roč. 136, Feb (2015), 625-634 ISSN 1386-1425 R&D Projects: GA ČR(CZ) GAP204/11/0809 Institutional support: RVO:68378271 Keywords : Oxovanadium(IV) complexes * Schiff base * Kinetics of thermal decomposition * Electrochemistry Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.653, year: 2015

  2. Crystallization and preliminary X-ray analysis of Escherichia coli MutT in binary and ternary complex forms.

    Science.gov (United States)

    Nakamura, Teruya; Doi, Takefumi; Sekiguchi, Mutsuo; Yamagata, Yuriko

    2004-09-01

    During replication, Escherichia coli MutT prevents the misincorporation of mutagenic 8-oxoguanine into nascent DNA strands opposite adenine by hydrolyzing 8-oxo-dGTP in nucleotide pools to 8-oxo-dGMP. E. coli MutT is the most widely investigated member of the Nudix hydrolase family, which is large and found in all organisms. By co-crystallization of MutT with 8-oxo-dGMP, a reaction product, crystals of the binary complex were obtained using ammonium sulfate as a precipitant. The crystals belong to space group P2(1)2(1)2(1), with unit-cell parameters a = 37.9, b = 56.0, c = 59.4 A. Assuming the presence of one protein-nucleotide complex in the asymmetric unit, the Matthews coefficient V(M) is 2.1 A(3) Da(-1). Crystals of the ternary complex were prepared by soaking crystals of the binary complex in 1 mM MnCl(2) solution. They diffracted to 1.96 and 2.56 A resolution, respectively.

  3. Synthesis, characterization, electrochemical studies and X-ray structures of mixed-ligand polypyridyl copper(II complexes with the acetate

    Directory of Open Access Journals (Sweden)

    Adekunle Oluwafunmilayo F.

    2016-01-01

    Full Text Available [Cu(phen2(CH3COO](ClO4.2H2O (1 and [Cu(bipy2(CH3COO]-(ClO4.H2O (2 {phen = 1,10-phenanthroline, bipy = 2,2’-bipyridine}were synthesized and characterized. The complexes were characterized by employying elemental analyses, infrared and UV-Visible spectroscopy, room temperature magnetic measurements and the crystal structures elucidated using X-ray diffraction experiment. The redox properties of the complexes were also investigated. Both structures have a square pyramidal CuN4O chromophore which exhibit significant distortions due to long Cu-O [2.217(3 Å for (1 and 2.179 (1 for (2] and Cu-N [2.631(2 Å for (1 and 2.714(1 Å for (2] bonds. This distortion if further shown by the O-Cu-N bond angles [147.71(8 o for (1 and 153.40(5 o for (2]. The elemental analyses further support the structural details unveiled by the single crystal X-ray diffraction analysis. The infrared spectra shows the acetate vibrational frequencies at 1587 cm-1,1428 cm-1, 1314 cm-1 for (1 and 1571 cm-1, 1441 cm-1, 1319c m-1 for (2 and the perchlo-rate bands at 1059 cm-1, 720 cm-1 (1 and 1080 cm-1,768 cm-1 (2. The broad d-d bands for the copper ion at 14,514 cm-1(1 and 14,535 cm-1(2 support the adoption of square pyramid geometries. The magnetic moments for the two complexes are 1.83 B.M for (1 and 1.72 B.M for (2. The peak to peak values of the two complexes show that the electrode reactions are quasi-reversibile with ΔEp = 0.023V (1 and 0.025V for (2. In both structures, there are π-π intermolecular interactions in addition to hydrogen bonding between the units.

  4. Design of novel HIV-1 protease inhibitors incorporating isophthalamide-derived P2-P3 ligands: Synthesis, biological evaluation and X-ray structural studies of inhibitor-HIV-1 protease complex

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Arun K.; Brindisi, Margherita; Nyalapatla, Prasanth R.; Takayama, Jun; Ella-Menye, Jean-Rene; Yashchuk, Sofiya; Agniswamy, Johnson; Wang, Yuan-Fang; Aoki, Manabu; Amano, Masayuki; Weber, Irene T.; Mitsuya, Hiroaki

    2017-10-01

    Based upon molecular insights from the X-ray structures of inhibitor-bound HIV-1 protease complexes, we have designed a series of isophthalamide-derived inhibitors incorporating substituted pyrrolidines, piperidines and thiazolidines as P2-P3 ligands for specific interactions in the S2-S3 extended site. Compound 4b has shown an enzyme Ki of 0.025 nM and antiviral IC50 of 69 nM. An X-ray crystal structure of inhibitor 4b-HIV-1 protease complex was determined at 1.33 Å resolution. We have also determined X-ray structure of 3b-bound HIV-1 protease at 1.27 Å resolution. These structures revealed important molecular insight into the inhibitor–HIV-1 protease interactions in the active site.

  5. X-ray diffraction

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of literature on X-ray diffraction begins with a list of conference proceedings on the subject, organised by the Philips' organisation at regular intervals in various European countries. This is followed by a list of bulletins. The bibliography is divided according to the equipment (cameras, diffractometers, monochromators) and its applications. The applications are subdivided into sections for high/low temperature and pressure, effects due to the equipment, small angle scattering and a part for stress, texture and phase analyses of metals and quantitative analysis of minerals

  6. Obstetric X-rays

    International Nuclear Information System (INIS)

    Mwachi, M.K.

    2006-01-01

    Radiography of the pelvis should never be taken to diagnose early pregnancy, because of potential hazards of radiation damage to the growing foetus. the only indication occurs in the last week of pregnancy (37 weeks). Obstetric X-ray will help you answer like confirmation of malposition,multiple pregnancies; fetal abnormalities e.g. hydrocephalus, foetal disposition. The choice of radiographic projection will help give foetal presentation, disposition as well as foetal maturity. The search pattern helps you determine maternal and spine deformity, foetal spine and head , foetal presentation and any other anomalies

  7. Examination of Libby, Montana, Fill Material for Background Levels of Amphibole from the Rainy Creek Complex Using Scanning Electron Microscopy and X-Ray Microanalysis

    Science.gov (United States)

    Adams, David T.; Langer, William H.; Hoefen, Todd M.; Van Gosen, Bradley S.; Meeker, Gregory P.

    2010-01-01

    Natural background levels of Libby-type amphibole in the sediment of the Libby valley in Montana have not, up to this point, been determined. The purpose of this report is to provide the preliminary findings of a study designed by both the U.S. Geological Survey and the U.S. Environmental Protection Agency and performed by the U.S. Geological Survey. The study worked to constrain the natural background levels of fibrous amphiboles potentially derived from the nearby Rainy Creek Complex. The material selected for this study was sampled from three localities, two of which are active open-pit sand and gravel mines. Seventy samples were collected in total and examined using a scanning electron microscope equipped with an energy dispersive x-ray spectrometer. All samples contained varying amounts of feldspars, ilmenite, magnetite, quartz, clay minerals, pyroxene minerals, and non-fibrous amphiboles such as tremolite, actinolite, and magnesiohornblende. Of the 70 samples collected, only three had detectable levels of fibrous amphiboles compatible with those found in the rainy creek complex. The maximum concentration, identified here, of the amphiboles potentially from the Rainy Creek Complex is 0.083 percent by weight.

  8. Expression, refolding and preliminary X-ray crystallographic analysis of equine MHC class I molecule complexed with an EIAV-Env CTL epitope

    International Nuclear Information System (INIS)

    Yao, Shugang; Qi, Jianxun; Liu, Jun; Chen, Rong; Pan, Xiaocheng; Li, Xiaoying; Gao, Feng; Xia, Chun

    2011-01-01

    The equine MHC class I molecule was crystallized in complex with β 2 -microglobulin and a CTL epitope and X-ray diffraction data were collected to 2.3 Å resolution. In order to clarify the structure and the peptide-presentation characteristics of the equine major histocompatibility complex (MHC) class I molecule, a complex of equine MHC class I molecule (ELA-A1 haplotype, 7-6 allele) with mouse β 2 -microglobulin and the cytotoxic T lymphocyte (CTL) epitope Env-RW12 (RVEDVTNTAEYW) derived from equine infectious anaemia virus (EIAV) envelope protein (residues 195–206) was refolded and crystallized. The crystal, which belonged to space group P2 1 , diffracted to 2.3 Å resolution and had unit-cell parameters a = 82.5, b = 71.4, c = 99.8 Å, β = 102.9°. The crystal structure contained two molecules in the asymmetric unit. These results should help to determine the first equine MHC class I molecule structure presenting an EIAV CTL epitope

  9. Small-Angle X-ray Scattering Study on Internal Microscopic Structures of Poly(N-isopropylacrylamide-co-tris(2,2'-bipyridyl))ruthenium(II) Complex Microgels.

    Science.gov (United States)

    Matsui, Shusuke; Kureha, Takuma; Nagase, Yasuhisa; Okeyoshi, Kosuke; Yoshida, Ryo; Sato, Takaaki; Suzuki, Daisuke

    2015-07-07

    Internal microscopic structures of poly(N-isopropylacrylamide-co-tris(2,2'-bipyridyl))ruthenium(II) complex microgels were investigated using small-angle X-ray scattering (SAXS) in the extended q-range of 0.07 ≤ q/nm(-1) ≤ 20. The microgels were prepared by aqueous free-radical precipitation polymerization, resulting in formation of monodispersed, submicrometer-sized microgels, which was confirmed by transmission electron microscopy and dynamic light scattering. To reveal the changes in the microscopic structures of the microgels during swelling/deswelling or dispersing/flocculating oscillation, the redox state of Ru(bpy)3 complexes was fixed in the microgels using Ce(IV) or Ce(III) ions under high ionic strength (1.5 M) during the SAXS measurements. The scattering intensity of the microgels manifested five different structural features. In particular, the correlation length (ξ), which was obtained from the fitting analysis using the Ornstein-Zernike equation, of the microgels both in the reduced and oxidized Ru(bpy)3 states exhibited divergent-like behavior. In addition, a low-q peak centered at q ≈ 5 nm(-1) did not appear clearly in both the reduced [Ru(bpy)3](2+) and oxidized [Ru(bpy)3](3+) states, indicating that the formation of a polymer-rich domain was suppressed; thus, Ru(bpy)3 complexes can be active even though the microgels are deswollen or flocculated during the oscillation reaction.

  10. Miniature X-Ray Tubes

    Science.gov (United States)

    Bearman, Gregory H.

    1995-01-01

    Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

  11. On the use of X-ray absorption spectroscopy to elucidate the structure of lutetium adenosine mono- and triphosphate complexes.

    Science.gov (United States)

    Mostapha, S; Berthon, C; Fontaine-Vive, F; Gaysinski, M; Guérin, L; Guillaumont, D; Massi, L; Monfardini, I; Solari, P L; Thomas, O P; Charbonnel, M C; Den Auwer, C

    2014-02-01

    Although the physiological impact of the actinide elements as nuclear toxicants has been widely investigated for half a century, a description of their interactions with biological molecules remains limited. It is however of primary importance to better assess the determinants of actinide speciation in cells and more generally in living organisms to unravel the molecular processes underlying actinide transport and deposition in tissues. The biological pathways of this family of elements in case of accidental contamination or chronic natural exposure (in the case of uranium rich soils for instance) are therefore a crucial issue of public health and of societal impact. Because of the high chemical affinity of those actinide elements for phosphate groups and the ubiquity of such chemical functions in biochemistry, phosphate derivatives are considered as probable targets of these cations. Among them, nucleotides and in particular adenosine mono- (AMP) and triphosphate (ATP) nucleotides occur in more chemical reactions than any other compounds on the earth's surface, except water, and are therefore critical target molecules. In the present study, we are interested in trans-plutonium actinide elements, in particular americium and curium that are more rarely considered in environmental and bioaccumulation studies than early actinides like uranium, neptunium and plutonium. A first step in this strategy is to work with chemical analogues like lanthanides that are not radioactive and therefore allow extended physical chemical characterization to be conducted that are difficult to perform with radioactive materials. We describe herein the interaction of lutetium(III) with adenosine AMP and ATP. With AMP and ATP, insoluble amorphous compounds have been obtained with molar ratios of 1:2 and 1:1, respectively. With an excess of ATP, with 1:2 molar ratio, a soluble complex has been obtained. A combination of spectroscopic techniques (IR, NMR, ESI-MS, EXAFS) together with quantum

  12. Synthesis, characterization and x-ray crystal structure of a dimethyltin (IV) dichloride complex of 2-acetylpyridine benzophenone azine

    International Nuclear Information System (INIS)

    Mustaffa Shamsuddin; Md Abu Affan; Ramli Atan

    1998-01-01

    Dimethyltin dichloride react with 2-ac ethylpyridine benzophenone azine (apba) in refluxing dry hexane to give (SnMe 2 Cl 2 (apba)) where the azine ligand acts as a bidentate N-N chelating ligand. The complex has been characterized by IR spectroscopy, 1 H and 13 C NMR spectroscopic data and elemental analyses. The crystal structure of the dimethyltin(IV) derivative has also been determined. Crystals are monoclinic with space group P2(1)/n with cell dimensions: a = 10.1819(3) Armstrong, b = 18.3113(5) Armstrong, c = 12.6451(4) Armstrong

  13. Soft x-ray lasers

    International Nuclear Information System (INIS)

    Matthews, D.L.; Rosen, M.D.

    1988-01-01

    One of the elusive dreams of laser physicists has been the development of an x-ray laser. After 25 years of waiting, the x-ray laser has at last entered the scientific scene, although those now in operation are still laboratory prototypes. They produce soft x rays down to about five nanometers. X-ray lasers retain the usual characteristics of their optical counterparts: a very tight beam, spatial and temporal coherence, and extreme brightness. Present x-ray lasers are nearly 100 times brighter that the next most powerful x-ray source in the world: the electron synchrotron. Although Lawrence Livermore National Laboratory (LLNL) is widely known for its hard-x-ray laser program which has potential applications in the Strategic Defense Initiative, the soft x-ray lasers have no direct military applications. These lasers, and the scientific tools that result from their development, may one day have a place in the design and diagnosis of both laser fusion and hard x-ray lasers. The soft x-ray lasers now in operation at the LLNL have shown great promise but are still in the primitive state. Once x-ray lasers become reliable, efficient, and economical, they will have several important applications. Chief among them might be the creation of holograms of microscopic biological structures too small to be investigated with visible light. 5 figs

  14. Purification, crystallization and preliminary X-ray diffraction analysis of the HMG domain of Sox17 in complex with DNA

    International Nuclear Information System (INIS)

    Ng, Calista Keow Leng; Palasingam, Paaventhan; Venkatachalam, Rajakannan; Baburajendran, Nithya; Cheng, Jason; Jauch, Ralf; Kolatkar, Prasanna R.

    2008-01-01

    Crystals of the Sox17 HMG domain bound to LAMA1 enhancer DNA-element crystals that diffracted to 2.75 Å resolution were obtained. Sox17 is a member of the SRY-related high-mobility group (HMG) of transcription factors that have been shown to direct endodermal differentiation in early mammalian development. The LAMA1 gene encoding the α-chain of laminin-1 has been reported to be directly bound and regulated by Sox17. This paper describes the details of initial crystallization attempts with the HMG domain of mouse Sox17 (mSox17-HMG) with a 16-mer DNA element derived from the LAMA1 enhancer and optimization strategies to obtain a better diffracting crystal. The best diffracting crystal was obtained in a condition containing 0.1 M Tris–HCl pH 7.4, 0.2 M MgCl 2 , 30% PEG 3350 using the hanging-drop vapour-diffusion method. A highly redundant in-house data set was collected to 2.75 Å resolution with 99% completeness. The presence of the mSox17-HMG–DNA complex within the crystals was confirmed and Matthews analysis indicated the presence of one complex per asymmetric unit

  15. X-ray tube

    International Nuclear Information System (INIS)

    Mayo, B.J.

    1980-01-01

    An x-ray tube in which the x-ray origin is scanned on a circle around the patient, comprises a ring-shaped anode, an electron beam travelling along a circular path being deflected onto the anode at the desired positions. The electron beam path may be in a plane parallel to the anode and perhaps at the same radius. It may be in the same plane as a transmission target/anode and at a greater radius. The anode should extend over at least 180 0 although it may extend to 360 0 . Electrostatic means may be provided to constrain the beam to the circular path and further electrostatic means deflect it to the anode of the beam and ensure it is focused at the point of incidence. Collimators provide a planar fan-shaped beam and the anode may be shaped to attenuate side lobes of the radiation. Electrode collects electrons not deflected. The focal regions may be adjacent or otherwise. Coils may provide periodic focusing to overcome space charge dispersion and dynamic adjustment of the focusing before deflection ensures focusing at target incidence. Focusing may be absent near the deflection region, and current in the coil section near the focal region should be zero. (author)

  16. Combining NMR and small angle X-ray and neutron scattering in the structural analysis of a ternary protein-RNA complex

    International Nuclear Information System (INIS)

    Hennig, Janosch; Wang, Iren; Sonntag, Miriam; Gabel, Frank; Sattler, Michael

    2013-01-01

    Many processes in the regulation of gene expression and signaling involve the formation of protein complexes involving multi-domain proteins. Individual domains that mediate protein-protein and protein-nucleic acid interactions are typically connected by flexible linkers, which contribute to conformational dynamics and enable the formation of complexes with distinct binding partners. Solution techniques are therefore required for structural analysis and to characterize potential conformational dynamics. Nuclear magnetic resonance spectroscopy (NMR) provides such information but often only sparse data are obtained with increasing molecular weight of the complexes. It is therefore beneficial to combine NMR data with additional structural restraints from complementary solution techniques. Small angle X-ray/neutron scattering (SAXS/SANS) data can be efficiently combined with NMR-derived information, either for validation or by providing additional restraints for structural analysis. Here, we show that the combination of SAXS and SANS data can help to refine structural models obtained from data-driven docking using HADDOCK based on sparse NMR data. The approach is demonstrated with the ternary protein-protein-RNA complex involving two RNA recognition motif (RRM) domains of Sex-lethal, the N-terminal cold shock domain of Upstream-to-N-Ras, and msl-2 mRNA. Based on chemical shift perturbations we have mapped protein-protein and protein-RNA interfaces and complemented this NMR-derived information with SAXS data, as well as SANS measurements on subunit-selectively deuterated samples of the ternary complex. Our results show that, while the use of SAXS data is beneficial, the additional combination with contrast variation in SANS data resolves remaining ambiguities and improves the docking based on chemical shift perturbations of the ternary protein-RNA complex.

  17. A zinc(II) quinolinone complex (Et3NH)[Zn(qui)Cl2]: Synthesis, X-ray structure, spectral properties and in vitro cytotoxicity

    Science.gov (United States)

    Buchtík, Roman; Nemec, Ivan; Trávníček, Zdeněk

    2014-02-01

    A new zinc(II) complex with 2-phenyl-3-hydroxy-4(1H)-quinolinone (Hqui) of the composition (Et3NH)[Zn(qui)Cl2] was prepared and characterized by elemental analysis, FT IR, 1D and 2D NMR, and fluorescence spectroscopy, mass spectrometry and single crystal X-ray analysis. The molecular structure is composed of the triethylammonium (Et3NH+) cations and tetrahedral [ZnII(qui)Cl2]- complex anions, in which the Zn(II) atoms are bidentate coordinated by one qui ligand through keto (OK) and phenolate (OP) oxygen atoms and by two chlorido ligands, thus forming the {O2Cl2} donor set, with Zn-OK = 1.9860(14) Å, Zn-OP 1.9961(14) Å and Zn-Cl = 2.2509(6) Å and 2.2266(6) Å. The complex cations are aligned into 1D supramolecular chains through the NH⋯Cl hydrogen bonding between the amine group of the quinolinone ligand and the chlorido ligand of the adjacent complex anion. The amine group from the Et3NH+ cations provides the NH⋯OP hydrogen bond with the phenolate oxygen atoms from the complex anion. Screening of in vitro cytotoxicity of the compound was studied on human osteosarcoma (HOS) and human breast adenocarcinoma (MCF7) cell lines, with IC50 > 50 μM. The fluorescence study showed that the complex exhibits a relatively high integral intensity (29%) as compared to the standard quinine sulfate, and 1.6-fold enhancement of emission with respect to free Hqui.

  18. Unusual saccharin-N,O (carbonyl) coordination in mixed-ligand copper(II) complexes: Synthesis, X-ray crystallography and biological activity

    Science.gov (United States)

    Mokhtaruddin, Nur Shuhada Mohd; Yusof, Enis Nadia Md; Ravoof, Thahira B. S. A.; Tiekink, Edward R. T.; Veerakumarasivam, Abhi; Tahir, Mohamed Ibrahim Mohamed

    2017-07-01

    Three tridentate Schiff bases containing N and S donor atoms were synthesized via the condensation reaction between S-2-methylbenzyldithiocarbazate with 2-acetyl-4-methylpyridine (S2APH); 4-methyl-3-thiosemicarbazide with 2-acetylpyridine (MT2APH) and 4-ethyl-3-thiosemicarbazide with 2-acetylpyridine (ET2APH). Three new, binuclear and mixed-ligand copper(II) complexes with the general formula, [Cu(sac)(L)]2 (sac = saccharinate anion; L = anion of the Schiff base) were then synthesized, and subsequently characterized by IR and UV/Vis spectroscopy as well as by molar conductivity and magnetic susceptibility measurements. The Schiff bases were also spectroscopically characterized using NMR and MS to further confirm their structures. The spectroscopic data indicated that the Schiff bases behaved as a tridentate NNS donor ligands coordinating via the pyridyl-nitrogen, azomethine-nitrogen and thiolate-sulphur atoms. Magnetic data indicated a square pyramidal environment for the complexes and the conductivity values showed that the complexes were essentially non-electrolytes in DMSO. The X-ray crystallographic analysis of one complex, [Cu(sac)(S2AP)]2 showed that the Cu(II) atom was coordinated to the thiolate-S, azomethine-N and pyridyl-N donors of the S2AP Schiff base and to the saccharinate-N from one anion, as well as to the carbonyl-O atom from a symmetry related saccharinate anion yielding a centrosymmetric binuclear complex with a penta-coordinate, square pyramidal geometry. All the copper(II) saccharinate complexes were found to display strong cytotoxic activity against the MCF-7 and MDA-MB-231 human breast cancer cell lines.

  19. Preparation and Single-Crystal X-Ray Structures of Four Related Mixed-Ligand 4-Methylpyridine Indium Halide Complexes

    Science.gov (United States)

    Hepp, Aloysius F.; Clark, Eric B.; Schupp, John D.; Williams, Jennifer N.; Duraj, Stan A.; Fanwick, Philip E.

    2013-01-01

    We describe the structures of four related indium complexes obtained during synthesis of solid-state materials precursors. Indium adducts of halides and 4-methylpyridine, InX3(pic)3 (X = Cl, Br; pic = 4-methylpyridine) consist of octahedral molecules with meridional (mer) geometry. Crystals of mer-InCl3(pic)3 (1) are triclinic, space group P1(bar) (No. 2), with a = 9.3240(3), b = 13.9580(6), c = 16.7268 (7) A, alpha = 84.323(2), beta = 80.938(2), gamma = 78.274(3)Z = 4, R = 0.035 for 8820 unique reflections. Crystals of mer-InBr3(pic)3 (2) are monoclinic, space group P21/n (No. 14), with a = 15.010(2), b = 19.938(2), c = 16.593(3), beta = 116.44(1)Z = 8, R = 0.053 for 4174 unique reflections. The synthesis and structures of related compounds with phenylsulfide (chloride) (3) and a dimeric complex with bridging hydroxide (bromide) (4) coordination is also described. Crystals of trans-In(SC6H5)Cl2(pic)3 (3) are monoclinic, space group P21/n (No. 14), with a = 9.5265(2), b = 17.8729(6), c = 13.8296(4), beta = 99.7640(15)Z = 4, R = 0.048 for 5511 unique reflections. Crystals of [In(mu-OH)Br2(pic)22 (4) are tetragonal, space group = I41cd (No. 110) with a = 19.8560(4), b = 19.8560(4), c = 25.9528(6), Z = 8, R = 0.039 for 5982 unique reflections.

  20. Synthesis, NMR characterization, X-ray crystal structure of Co(II) Ni(II) and Cu(II) complexes of a pyridine containing self-assembling

    International Nuclear Information System (INIS)

    Ranjbar, M.; Taghavipour, M.; Moghimi, A.; Aghabozorg, H.

    2002-01-01

    In the recent years, the self-assembling systems have been attracted chemists. The intermolecular bond in such systems mainly consists of ion pairing and hydrogen bonding [1,2]. The reaction between self-assembling system liquid LH 2 (py dc=2,6-pyridinedicarboxylic acid and py da=2,6- pyridine diamin) with cobalt (II) nitrate, nickel (II) chloride, and copper (II) acetate in water leads to the formation of self- assemble coordination complexes, [py da.H] 2 [M(py dc) 2 ]. H 2 O, M=Co(II),Ni(II), and Cu(II). The characterization was performed using elemental analysis, ESI mass spectroscopy, 1 H and 13 C NMR and X-ray crystallography. The crystal systems are monoclinic with space group P2 1 /n and four molecules per unit cell. These complexes shows 13 C NMR resonances of cationic counter ion [(py dc,H)] + in DMSO- d 6 but no signal corresponding to the two coordinated ligands [py dc] 2- The metal atoms are six-coordinated with a distorted octahedral geometry. The two [py de] 2- units are almost perpendicular to each other

  1. Synthesis and X-ray Crystal Structure of a Stable cis-1,2-bis(diphenylphosphinoethene Monodentate Thiolate Platinum Complex and TGA Studies of its Precursors

    Directory of Open Access Journals (Sweden)

    Vaz Rodrigo H.

    2002-01-01

    Full Text Available The stable Pt(II complex [Pt(SPh2(dppen (4, (dppen, Ph2PCH=CHPPh2 was obtained from [PtCl(SPh2(SnPh3cod] (1 (cod = 1,5-cyclooctadiene by reductive elimination reaction of SnClPh3 and substitution of the cod ligand by the diphosphine, albeit in low yields. Yields of 80% were obtained when [Pt(SPh2cod] (3 was used as the starting material instead. The viability of these reactions was suggested by a TG study, performed on the starting materials. Complex 4 was characterized by multinuclear NMR (195Pt, 31P, ¹H and 13C and IR spectroscopies and elemental analysis. The molecular structure, solved by an X-ray diffraction study, exhibted a slightly distorted square-planar geometry and short C=C and Pt-P bond distances which were interpreted in terms of a p interaction between the double bond and the metal-ligand bond, as observed for other diphosphine compounds described previously.

  2. Evaluation of micro-energy dispersive X-ray fluorescence and histochemical tests for aluminium detection in plants from High Altitude Rocky Complexes, Southeast Brazil

    Directory of Open Access Journals (Sweden)

    NAIARA V. CAMPOS

    2014-03-01

    Full Text Available The soils developed under High Altitude Rocky Complexes in Brazil are generally of very low chemical fertility, with low base saturation and high exchangeable aluminium concentration. This stressful condition imposes evolutionary pressures that lead to ecological success of plant species that are able to tolerate or accumulate high amounts of aluminium. Several analytical methods are currently available for elemental mapping of biological structures, such as micro-X-ray fluorescence (μ-EDX and histochemical tests. The aim of this study was to combine μ-EDX analysis and histochemical tests to quantify aluminium in plants from High Altitude Rocky Complexes, identifying the main sites for Al-accumulation. Among the studied species, five showed total Al concentration higher than 1000 mg kg−1. The main Al-hyperaccumulator plants, Lavoisiera pectinata, Lycopodium clavatum and Trembleya parviflora presented positive reactions in the histochemical tests using Chrome Azurol and Aluminon. Strong positive correlations were observed between the total Al concentrations and data obtained by μ-EDX analysis. The μ-EDX analysis is a potential tool to map and quantify Al in hyperaccumulator species, and a valuable technique due to its non-destructive capacity. Histochemical tests can be helpful to indicate the accumulation pattern of samples before they are submitted for further μ-EDX scrutiny.

  3. Expression, purification, crystallization and preliminary X-ray analysis of calmodulin in complex with the regulatory domain of the plasma-membrane Ca2+-ATPase ACA8

    International Nuclear Information System (INIS)

    Tidow, Henning; Hein, Kim L.; Baekgaard, Lone; Palmgren, Michael G.; Nissen, Poul

    2010-01-01

    Plant plasma-membrane Ca 2+ -ATPase is regulated via binding of calmodulin to its autoinhibitory N-terminal domain. In this study, the expression, purification, crystallization and preliminary X-ray diffraction analysis of this protein complex from A. thaliana are reported. Plasma-membrane Ca 2+ -ATPases (PMCAs) are calcium pumps that expel Ca 2+ from eukaryotic cells to maintain overall Ca 2+ homoeostasis and to provide local control of intracellular Ca 2+ signalling. They are of major physiological importance, with different isoforms being essential, for example, for presynaptic and postsynaptic Ca 2+ regulation in neurons, feedback signalling in the heart and sperm motility. In the resting state, PMCAs are autoinhibited by binding of their C-terminal (in mammals) or N-terminal (in plants) tail to two major intracellular loops. Activation requires the binding of calcium-bound calmodulin (Ca 2+ -CaM) to this tail and a conformational change that displaces the autoinhibitory tail from the catalytic domain. The complex between calmodulin and the regulatory domain of the plasma-membrane Ca 2+ -ATPase ACA8 from Arabidopsis thaliana has been crystallized. The crystals belonged to space group C2, with unit-cell parameters a = 176.8, b = 70.0, c = 69.8 Å, β = 113.2°. A complete data set was collected to 3.0 Å resolution and structure determination is in progress in order to elucidate the mechanism of PMCA activation by calmodulin

  4. Purification, crystallization and preliminary X-ray diffraction analysis of the IL-20-IL-20R1-IL-20R2 complex

    Energy Technology Data Exchange (ETDEWEB)

    Logsdon, Naomi J.; Allen, Christopher E.; Rajashankar, Kanagalaghatta R.; Walter, Mark R. (Cornell); (UAB)

    2012-02-08

    Interleukin-20 (IL-20) is an IL-10-family cytokine that regulates innate and adaptive immunity in skin and other tissues. In addition to protecting the host from various external pathogens, dysregulated IL-20 signaling has been shown to contribute to the pathogenesis of human psoriasis. IL-20 signals through two cell-surface receptor heterodimers, IL-20R1-IL-20R2 and IL-22R1-IL-20R2. In this report, crystals of the IL-20-IL-20R1-IL-20R2 ternary complex have been grown from polyethylene glycol solutions. The crystals belonged to space group P4{sub 1}2{sub 1}2 or P4{sub 3}2{sub 1}2, with unit-cell parameters a = 111, c = 135 {angstrom}, and diffracted X-rays to 3 {angstrom} resolution. The crystallographic asymmetric unit contains one IL-20-IL-20R1-IL-20R2 complex, corresponding to a solvent content of approximately 54%.

  5. Evaluation of micro-energy dispersive X-ray fluorescence and histochemical tests for aluminium detection in plants from High Altitude Rocky Complexes, Southeast Brazil.

    Science.gov (United States)

    Campos, Naiara V; Pereira, Tiago A R; Machado, Mariana F; Guerra, Marcelo B B; Tolentino, Gláucia S; Araújo, Josiane S; Rezende, Maíra Q; Silva, Maria Carolina N A da; Schaefer, Carlos E G R

    2014-03-01

    The soils developed under High Altitude Rocky Complexes in Brazil are generally of very low chemical fertility, with low base saturation and high exchangeable aluminium concentration. This stressful condition imposes evolutionary pressures that lead to ecological success of plant species that are able to tolerate or accumulate high amounts of aluminium. Several analytical methods are currently available for elemental mapping of biological structures, such as micro-X-ray fluorescence (μ-EDX) and histochemical tests. The aim of this study was to combine μ-EDX analysis and histochemical tests to quantify aluminium in plants from High Altitude Rocky Complexes, identifying the main sites for Al-accumulation. Among the studied species, five showed total Al concentration higher than 1000 mg kg-1. The main Al-hyperaccumulator plants, Lavoisiera pectinata, Lycopodium clavatum and Trembleya parviflora presented positive reactions in the histochemical tests using Chrome Azurol and Aluminon. Strong positive correlations were observed between the total Al concentrations and data obtained by μ-EDX analysis. The μ-EDX analysis is a potential tool to map and quantify Al in hyperaccumulator species, and a valuable technique due to its non-destructive capacity. Histochemical tests can be helpful to indicate the accumulation pattern of samples before they are submitted for further μ-EDX scrutiny.

  6. Structural analysis of the yeast exosome Rrp6p–Rrp47p complex by small-angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Dedic, Emil; Seweryn, Paulina; Jonstrup, Anette Thyssen; Flygaard, Rasmus Koch [Centre for mRNP Biogenesis and Metabolism, Gustav Wieds Vej 10c, Aarhus University, DK-8000 Aarhus C (Denmark); Department of Molecular Biology and Genetics, Gustav Wieds Vej 10c, Aarhus University, DK-8000 Aarhus C (Denmark); Fedosova, Natalya U. [Department of Biomedicine, Ole Worms Allé 6, Aarhus University, DK-8000 Aarhus C (Denmark); Hoffmann, Søren Vrønning [Institute for Storage Ring Facilities (ISA), Department of Physics and Astronomy, Ny Munkegade 120, Aarhus University, DK-8000 Aarhus C (Denmark); Boesen, Thomas [Centre for Membrane Pumps in Cells and Disease – PUMPKIN, Gustav Wieds Vej 10c, Aarhus University, DK-8000 Aarhus C (Denmark); Department of Molecular Biology and Genetics, Gustav Wieds Vej 10c, Aarhus University, DK-8000 Aarhus C (Denmark); Brodersen, Ditlev Egeskov, E-mail: deb@mb.au.dk [Centre for mRNP Biogenesis and Metabolism, Gustav Wieds Vej 10c, Aarhus University, DK-8000 Aarhus C (Denmark); Department of Molecular Biology and Genetics, Gustav Wieds Vej 10c, Aarhus University, DK-8000 Aarhus C (Denmark)

    2014-07-18

    Highlights: • We show that S. cerevisiae Rrp6p and Rrp47p stabilise each other in vitro. • We determine molecular envelopes of the Rrp6p–Rrp47p complex by SAXS. • Rrp47p binds at the top of the Rrp6p exonuclease domain. • Rrp47p modulates the activity of Rrp6p on a variety of RNA substrates. • Rrp47p does not affect RNA affinity by Rrp6p. - Abstract: The RNase D-type 3′–5′ exonuclease Rrp6p from Saccharomyces cerevisiae is a nuclear-specific cofactor of the RNA exosome and associates in vivo with Rrp47p (Lrp1p). Here, we show using biochemistry and small-angle X-ray scattering (SAXS) that Rrp6p and Rrp47p associate into a stable, heterodimeric complex with an elongated shape consistent with binding of Rrp47p to the nuclease domain and opposite of the HRDC domain of Rrp6p. Rrp47p reduces the exonucleolytic activity of Rrp6p on both single-stranded and structured RNA substrates without significantly altering the affinity towards RNA or the ability of Rrp6p to degrade RNA secondary structure.

  7. Crystallization and preliminary X-ray characterization of the eukaryotic replication terminator Reb1-Ter DNA complex.

    Science.gov (United States)

    Jaiswal, Rahul; Singh, Samarendra K; Bastia, Deepak; Escalante, Carlos R

    2015-04-01

    The Reb1 protein from Schizosaccharomyces pombe is a member of a family of proteins that control programmed replication termination and/or transcription termination in eukaryotic cells. These events occur at naturally occurring replication fork barriers (RFBs), where Reb1 binds to termination (Ter) DNA sites and coordinates the polar arrest of replication forks and transcription approaching in opposite directions. The Reb1 DNA-binding and replication-termination domain was expressed in Escherichia coli, purified and crystallized in complex with a 26-mer DNA Ter site. Batch crystallization under oil was required to produce crystals of good quality for data collection. Crystals grew in space group P2₁, with unit-cell parameters a = 68.9, b = 162.9, c = 71.1 Å, β = 94.7°. The crystals diffracted to a resolution of 3.0 Å. The crystals were mosaic and required two or three cycles of annealing. This study is the first to yield structural information about this important family of proteins and will provide insights into the mechanism of replication and transcription termination.

  8. Stage-specific damage to synaptonemal complexes and metaphase chromosomes induced by X rays in male mouse germ cells

    International Nuclear Information System (INIS)

    Backer, L.C.; Sontag, M.R.; Allen, J.W.

    1991-01-01

    Synaptonemal complexes (SCs) reveal mutagen-induced effects in germ cell meiotic chromosomes. The study was aimed at characterizing relationships between SC and metaphase I chromosome damage following radiation exposure at various stages of spermatogenesis. Male mice were irradiated with doses of 0, 2, or 4 Gy, and spermatocytes were harvested at times consistent with earlier exposures as spermatogonial stem cells, preleptotene cells (premeiotic DNA synthesis), or meiotic prophase cells. After stem-cell exposure, twice as many rearrangements were observed in SCs as in metaphase I chromosomes. Irradiation during premeiotic DNA synthesis resulted in dose-related increases in SC breakage and rearrangements (including novel forms) and in metaphase chromosomal aberrations. Following prophase exposure, various types and levels of SC and metaphase damage were observed. Irradiation of zygotene cells led to high frequencies of chromosome multivalents in metaphase I without a correspondingly high level of damage in preceding prophase SCs. Thus, irradiation of premeiotic and meiotic cells results in variable relationships between SC and metaphase chromosome damage

  9. High-resolution neutron and X-ray diffraction room-temperature studies of an H-FABP–oleic acid complex: Study of the internal water cluster and ligand binding by a transferred multipolar electron-density distribution

    OpenAIRE

    Howard, E.I.; Guillot, B.; Blakeley, M.P.; Haertlein, M.; Moulin, M.; Mitschler, A.; Cousido-Siah, A.; Fadel, F.; Valsecchi, W.M.; Tomizaki, T.; Petrova, T.; Claudot, J.; Podjarny, A.

    2016-01-01

    Crystal diffraction data of heart fatty acid binding protein (H-FABP) in complex with oleic acid were measured at room temperature with high-resolution X-ray and neutron protein crystallography (0.98 and 1.90 Å resolution, respectively). These data provided very detailed information about the cluster of water molecules and the bound oleic acid in the H-FABP large internal cavity. The jointly refined X-ray/neutron structure of H-FABP was complemented by a transferred multipolar electron-densit...

  10. Polarized X-ray absorption spectroscopy of single-crystal Mn(V) complexes relevant to the oxygen-evolving complex of photosystem II

    DEFF Research Database (Denmark)

    Yano, Junko; Robblee, John; Pushkar, Yulia

    2007-01-01

    High-valent Mn-oxo species have been suggested to have a catalytically important role in the water splitting reaction which occurs in the Photosystem II membrane protein. In this study, five- and six-coordinate mononuclear Mn(V) compounds were investigated by polarized X-ray absorption spectroscopy...... structure of the metal site was then studied by measuring the polarization dependence of X-ray absorption near-edge spectroscopy (XANES) pre-edge spectra (1s to 3d transition) and comparing with the results of density functional theory (DFT) calculations. The Mn(V)-nitrido compound, in which the manganese......-edge peak. This component was interpreted as a 1s to 3d(xz,yz) transition with 4px,y mixing, due to the displacement of the Mn atom out of the equatorial plane. The XANES results have been correlated to DFT calculations, and the spectra have been simulated using a TD (time-dependent)-DFT approach...

  11. Identification of m = 2 competent mode of complex magneto-hydro-dynamics activities during internal soft disruption based on singular value decomposition and tomography of soft-X-ray emission on the HT-7 tokamak

    International Nuclear Information System (INIS)

    Xu Li-Qing; Hu Li-Qun; Li Er-Zhong; Chen Kai-Yun; Liu Zhi-Yuan; Chen Ye-Bin; Zhang Ji-Zong; Zhou Rui-Jie; Yang Mao; Mao Song-Tao; Duan Yan-Min

    2012-01-01

    In this paper, the singular value decomposition (SVD) method as a filter is applied before the tomographic inversion of soft-X-ray emission. Series of ‘filtered’ signals including specific chronos and topos are obtained. (Here, chronos and topos are the decomposed spatial vectors and the decomposed temporal vectors, respectively). Given specific magnetic flux function with coupling m = 1 and m = 2 modes, the line-integrated soft-X-ray signals at all chords have been obtained. Then m = 1 and m = 2 modes have been identified by tomography of simulated ‘filtered’ signals extracted by the SVD method. Finaly, using the experimental line-integrated soft-X-ray signals, m = 2 competent mode of complex magnetohydrodynamics(MHD) activities during internal soft disruption is observed. This result demonstrates that m = 2 mode plays an important role in internal disruption (Here, m is the poloidal mode number). (physics of gases, plasmas, and electric discharges)

  12. Simulating Ru L3-edge X-ray absorption spectroscopy with time-dependent density functional theory: model complexes and electron localization in mixed-valence metal dimers.

    Science.gov (United States)

    Van Kuiken, Benjamin E; Valiev, Marat; Daifuku, Stephanie L; Bannan, Caitlin; Strader, Matthew L; Cho, Hana; Huse, Nils; Schoenlein, Robert W; Govind, Niranjan; Khalil, Munira

    2013-05-30

    Ruthenium L3-edge X-ray absorption (XA) spectroscopy probes unoccupied 4d orbitals of the metal atom and is increasingly being used to investigate the local electronic structure in ground and excited electronic states of Ru complexes. The simultaneous development of computational tools for simulating Ru L3-edge spectra is crucial for interpreting the spectral features at a molecular level. This study demonstrates that time-dependent density functional theory (TDDFT) is a viable and predictive tool for simulating ruthenium L3-edge XA spectroscopy. We systematically investigate the effects of exchange correlation functional and implicit and explicit solvent interactions on a series of Ru(II) and Ru(III) complexes in their ground and electronic excited states. The TDDFT simulations reproduce all of the experimentally observed features in Ru L3-edge XA spectra within the experimental resolution (0.4 eV). Our simulations identify ligand-specific charge transfer features in complicated Ru L3-edge spectra of [Ru(CN)6](4-) and Ru(II) polypyridyl complexes illustrating the advantage of using TDDFT in complex systems. We conclude that the B3LYP functional most accurately predicts the transition energies of charge transfer features in these systems. We use our TDDFT approach to simulate experimental Ru L3-edge XA spectra of transition metal mixed-valence dimers of the form [(NC)5M(II)-CN-Ru(III)(NH3)5](-) (where M = Fe or Ru) dissolved in water. Our study determines the spectral signatures of electron delocalization in Ru L3-edge XA spectra. We find that the inclusion of explicit solvent molecules is necessary for reproducing the spectral features and the experimentally determined valencies in these mixed-valence complexes. This study validates the use of TDDFT for simulating Ru 2p excitations using popular quantum chemistry codes and providing a powerful interpretive tool for equilibrium and ultrafast Ru L3-edge XA spectroscopy.

  13. From X-rays microscopies imaging and control to the realization of nanoscale up to mesoscale complex materials with precisely tuned correlated disorder

    Directory of Open Access Journals (Sweden)

    Nicola Poccia

    2016-01-01

    Full Text Available With the advent of novel X-ray optics technologies, it has now become possible to focalize X-rays downwards to about 50 nm. This advantage has been exploited both in physical and biological sciences in order to map the k-space characteristics onto the real space of the material. Here we will review the role X-ray microscopies have played in the field of ferroelectrics and high temperature superconductivity since the discovery of fractal self-organization of nanoscale electronic structures in the material. We will point out that the statistical analysis of weak X-ray signals due to superstructures has given unique information on the pattern and disorder displayed by the nanostructure in these materials. Now, the problem is to understand how to manipulate and control these mesoscopic nanoscale electronic and disordered systems in order to lay the basis for the development of competitive electronics. For example, continuous X-ray irradiation is a tool that can be used to control quenched disorder such as oxygen interstitials in cuprates and will therefore be reviewed. However, the artificial design of novel electronic nanoscale materials can also benefit from this information. Indeed, inspired by the nanoscale pattern observed in ferroelectric and superconducting materials with X-ray microscopies, we will discuss the design of nanoscale electronic systems with precisely tuned correlated disorder up to the mesoscale.

  14. Introduction to the structures determination methods using X-ray diffraction in monocrystals: application to some lanthanides and transition metals complexes with organic ligands

    International Nuclear Information System (INIS)

    Oliva, G.

    1983-01-01

    The crystal structure of the complexes Ln (Cl O 4 ) 3 .6[P O N H 2 (C 6 H 5 ) 2 ] where Ln = Eu, La, Cu[N H 2 (C H 3 ) 2 C C O 2 ] 2 , Ni Br 2 .4[As O(C 6 H 5 ) 3 ]. 8 H 2 O (green), Ni Br 2 .4[As O (C 6 H 5 ) 3 ]. 1,5 (C H 3 C 6 H 5 ).H 2 O (orange) and of the ligand P O N H 2 (C 6 H 5 ) 2 have been determined by X-ray diffraction. The complexes involving lanthanide ions refined to final R factors of R(Eu) = 0.125 and R(La) = 0.133 and the following main features were found: the crystal system is cubic; the cation is coordinated to six ligand oxygens in octahedral (Eu) and trigonal anti prismatic (La) configurations with the rate earths on positions of high symmetry (23 for Eu and 3-bar for La); the rest of the structures shows different degrees of disorder. In the light of the geometrical configuration, the occurrence of a strong band 5 D O - 7 F 2 in the fluorescence spectrum of the Eu complex, forbidden on symmetry grounds, is interpreted as a consequence of vibronic coupling. A splitting of the infrared ν P=0 band in the La complex is attributed to the presence of P = 0 groups non-equivalently bonded to the rare earth due to the disorder of this atom. (author)

  15. Study of solid/liquid and solid/gas interfaces in Cu–isoleucine complex by surface X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Ferrer, Pilar, E-mail: ferreres@esrf.fr [SpLine Spanish CRG Beamline at the ESRF, 38000 Grenoble (France); Instituto de Ciencia de Materiales de Madrid, 28049 Madrid (Spain); Rubio-Zuazo, Juan; Castro, German R. [SpLine Spanish CRG Beamline at the ESRF, 38000 Grenoble (France); Instituto de Ciencia de Materiales de Madrid, 28049 Madrid (Spain)

    2013-02-15

    The enzymes could be understood like structures formed by amino acids bonded with metals, which act as active sites. The research on the coordination of metal–amino acid complexes will bring light on the behavior of metal enzymes, due to the close relation existing between the atomic structure and the functionality. The Cu–isoleucine bond is considered as a good model system to attain a better insight into the characteristics of naturally occurring copper metalloproteins. The surface structure of metal–amino acid complex could be considered as a more realistic model for real systems under biologic working conditions, since the molecular packing is decreased. In the surface, the structural constrains are reduced, keeping the structural capability of surface complex to change as a function of the surrounding environment. In this work, we present a surface X-ray diffraction study on Cu–isoleucine complex under different ambient conditions. Cu(Ile){sub 2} crystals of about 5 mm × 5 mm × 1 mm have been growth, by seeding method in a supersaturated solution, presenting a surface of high quality. The sample for the surface diffraction study was mounted on a cell specially designed for solid/liquid or solid/gas interface analysis. The Cu–isoleucine crystal was measured under a protective dry N{sub 2} gas flow and in contact with a saturated metal amino acid solution. The bulk and the surface signals were compared, showing different atomic structures. In both cases, from surface diffraction data, it is observed that the atomic structure of the top layer undergoes a clear structural deformation. A non-uniform surface relaxation is observed producing an inhomogeneous displacement of the surface atoms towards the surface normal.

  16. Silver(I) complexation of linked 2,2'-dipyridylamine derivatives. Synthetic, solvent extraction, membrane transport and X-ray structural studies.

    Science.gov (United States)

    Antonioli, Bianca; Bray, David J; Clegg, Jack K; Gloe, Kerstin; Gloe, Karsten; Kataeva, Olga; Lindoy, Leonard F; McMurtrie, John C; Steel, Peter J; Sumby, Christopher J; Wenzel, Marco

    2006-10-28

    Synthesis of the 2,2'-dipyridylamine derivatives di-2-pyridylaminomethylbenzene 1, 1,2-bis(di-2-pyridylaminomethyl)benzene 2, 1,3-bis(di-2-pyridylaminomethyl)benzene 3, 2,6-bis(di-2-pyridylaminomethyl)pyridine 4, 1,4-bis(di-2-pyridylaminomethyl)benzene 5, and 1,3,5-tris(di-2-pyridylaminomethyl)benzene 6 are reported together with the single-crystal X-ray structures of 2, 3, and 5. Reaction of individual salts of the type AgX (where X = NO(3)(-), PF(6)(-), ClO(4)(-), or BF(4)(-)) with the above ligands has led to the isolation of thirteen Ag(I) complexes, nine of which have also been characterised by X-ray diffraction. In part, the inherent flexibility of the respective ligands has resulted in the adoption of a range of coordination arrangements. A series of liquid-liquid (H(2)O/CHCl(3)) extraction experiments of Ag(I) with varying concentrations of 1-6 in the organic phase have been undertaken, with the counter ion in the aqueous phase being respectively picrate, perchlorate and nitrate. In general, extraction efficiencies for a given ionophore followed the Hofmeister order of picrate > perchlorate > nitrate; in each case the tris-dpa derivative 6 acting as the most efficient extractant of the six systems investigated. Competitive seven-metal bulk membrane transport experiments (H(2)O/CHCl(3)/H(2)O) employing the above ligands as the ionophore in the organic phase and equimolar concentrations of Co(II), Ni(II), Zn(II), Cu(II), Cd(II), Pb(II) and Ag(I) in the aqueous source phase were also undertaken, with transport occurring against a pH gradient. Under the conditions employed 1 and 5 yielded negligible transport of any of the metals present in the source phase while sole transport selectivity for Ag(I) was observed for 2-4 and 6.

  17. X-ray table

    International Nuclear Information System (INIS)

    Craig, J.R.; Otto, G.W.

    1980-01-01

    An X-ray radiographic or fluoroscopic table is described which includes a film holder with a frame attached to a cable running over end pulleys for positioning the holder longitudinally as desired under the table top. The holder has a front opening to receive a cassette-supporting tray which can be slid out on tracks to change the cassette. A reed switch on the frame is opened by a permanent magnet on the tray only when the tray is half-way out. When the switch is closed, an electromagnet locks the pulley and the holder in place. The holder is thus automatically locked in place not only during exposure (tray in) but when the tray is out for changing the cassette. To re-position the holder, the operator pulls the tray half-out and, using the tray itself, pushes the holder along the table, the holder being counterbalanced by a weight. (author)

  18. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  19. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  20. Synthesis, spectra and X-ray crystallography of dipyridin-2-ylmethanone oxime and its CuX2(oxime)2 complexes: Thermal, Hirshfeld surface and DFT analysis

    Science.gov (United States)

    Warad, Ismail; Abdoh, Muneer; Al Ali, Anas; Shivalingegowda, Naveen; Kumara, Karthik; Zarrouk, Abdelkader; Lokanath, Neartur Krishnappagowda

    2018-02-01

    Dipyridin-2-ylmethanone oxime (C11H9N3O), was prepared using di-2-pyridyl ketone. The oxime ligand and its neutral CuX2 (oxime)2 (X = Cl or Br) complexes have been identified with the aid of several spectroscopic techniques such as: IR, EI-MS, EA, UV-visible, TG, 1H-NMR and finally the structure of the free oxime ligand was confirmed by X-ray diffraction studies. The oxime crystallizes in the monoclinic space group P21/c, with cell parameters a = 8.8811 (8) Å, b = 10.6362 (8) Å, c = 11.2050 (8) Å, β = 109.085 (4) º, V = 1000.26 (14) Å3 and Z = 4. The molecular conformation is stabilized by a strong intramolecular Osbnd H⋯N hydrogen bonding between the hydroxyl group of the oxime moiety and the nitrogen of the pyridine ring. Since the oxime structure was solved by XRD, the ligand structure parameters like bond length and angles were compared to the DFT computed one, the UV-visible to TD-SCF and Hirshfeld surface to MEP analysis.

  1. Structure of a complex of uridine phosphorylase from Yersinia pseudotuberculosis with the modified bacteriostatic antibacterial drug determined by X-ray crystallography and computer analysis

    International Nuclear Information System (INIS)

    Balaev, V. V.; Lashkov, A. A.; Gabdoulkhakov, A. G.; Seregina, T. A.; Dontsova, M. V.; Mikhailov, A. M.

    2015-01-01

    Pseudotuberculosis and bubonic plague are acute infectious diseases caused by the bacteria Yersinia pseudotuberculosis and Yersinia pestis. These diseases are treated, in particular, with trimethoprim and its modified analogues. However, uridine phosphorylases (pyrimidine nucleoside phosphorylases) that are present in bacterial cells neutralize the action of trimethoprim and its modified analogues on the cells. In order to reveal the character of the interaction of the drug with bacterial uridine phosphorylase, the atomic structure of the unligated molecule of uridine-specific pyrimidine nucleoside phosphorylase from Yersinia pseudotuberculosis (YptUPh) was determined by X-ray diffraction at 1.7 Å resolution with high reliability (R work = 16.2, R free = 19.4%; r.m.s.d. of bond lengths and bond angles are 0.006 Å and 1.005°, respectively; DPI = 0.107 Å). The atoms of the amino acid residues of the functionally important secondary-structure elements—the loop L9 and the helix H8—of the enzyme YptUPh were located. The three-dimensional structure of the complex of YptUPh with modified trimethoprim—referred to as 53I—was determined by the computer simulation. It was shown that 53I is a pseudosubstrate of uridine phosphorylases, and its pyrimidine-2,4-diamine group is located in the phosphate-binding site of the enzyme YptUPh

  2. In situ X-ray data collection from highly sensitive crystals of Pseudomonas putida PtxS in complex with DNA

    International Nuclear Information System (INIS)

    Pineda-Molina, E.; Daddaoua, A.; Krell, T.; Ramos, J. L.; García-Ruiz, J. M.; Gavira, J. A.

    2012-01-01

    The crystallization of both native P. putida transcriptional regulator PtxS and its complex with its DNA recognition sequence using the counter-diffusion method are reported. Pseudomonas putida PtxS is a member of the LacI protein family of transcriptional regulators involved in glucose metabolism. All genes involved in this pathway are clustered into two operons, kgu and gad. PtxS controls the expression of the kgu and gad operons as well as its own transcription. The PtxS operator is a perfect palindrome, 5′-TGAAACCGGTTTCA-3′, which is present in all three promoters. Crystallization of native PtxS failed, and PtxS–DNA crystals were finally produced by the counter-diffusion technique. A portion of the capillary used for crystal growth was attached to the end of a SPINE standard cap and directly flash-cooled in liquid nitrogen for diffraction tests. A full data set was collected with a beam size of 10 × 10 µm. The crystal belonged to the trigonal space group P3, with unit-cell parameters a = b = 213.71, c = 71.57 Å. Only unhandled crystals grown in capillaries of 0.1 mm inner diameter diffracted X-rays to 1.92 Å resolution

  3. Structure of a complex of uridine phosphorylase from Yersinia pseudotuberculosis with the modified bacteriostatic antibacterial drug determined by X-ray crystallography and computer analysis

    Energy Technology Data Exchange (ETDEWEB)

    Balaev, V. V.; Lashkov, A. A., E-mail: alashkov83@gmail.com; Gabdoulkhakov, A. G.; Seregina, T. A.; Dontsova, M. V.; Mikhailov, A. M. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2015-03-15

    Pseudotuberculosis and bubonic plague are acute infectious diseases caused by the bacteria Yersinia pseudotuberculosis and Yersinia pestis. These diseases are treated, in particular, with trimethoprim and its modified analogues. However, uridine phosphorylases (pyrimidine nucleoside phosphorylases) that are present in bacterial cells neutralize the action of trimethoprim and its modified analogues on the cells. In order to reveal the character of the interaction of the drug with bacterial uridine phosphorylase, the atomic structure of the unligated molecule of uridine-specific pyrimidine nucleoside phosphorylase from Yersinia pseudotuberculosis (YptUPh) was determined by X-ray diffraction at 1.7 Å resolution with high reliability (R{sub work} = 16.2, R{sub free} = 19.4%; r.m.s.d. of bond lengths and bond angles are 0.006 Å and 1.005°, respectively; DPI = 0.107 Å). The atoms of the amino acid residues of the functionally important secondary-structure elements—the loop L9 and the helix H8—of the enzyme YptUPh were located. The three-dimensional structure of the complex of YptUPh with modified trimethoprim—referred to as 53I—was determined by the computer simulation. It was shown that 53I is a pseudosubstrate of uridine phosphorylases, and its pyrimidine-2,4-diamine group is located in the phosphate-binding site of the enzyme YptUPh.

  4. Crystallization and preliminary X-ray diffraction of the DEAD-box protein Mss116p complexed with an RNA oligonucleotide and AMP-PNP

    Energy Technology Data Exchange (ETDEWEB)

    Del Campo, Mark; Lambowitz, Alan M.; (Texas)

    2009-09-02

    The Saccharomyces cerevisiae DEAD-box protein Mss116p is a general RNA chaperone which functions in mitochondrial group I and group II intron splicing, translation and RNA-end processing. For crystallization trials, full-length Mss116p and a C-terminally truncated protein (Mss116p/{Delta}598-664) were overproduced in Escherichia coli and purified to homogeneity. Mss116p exhibited low solubility in standard solutions ({le}1 mg ml{sup -1}), but its solubility could be increased by adding 50 mM L-arginine plus 50 mM L-glutamate and 50% glycerol to achieve concentrations of {approx}10 mg ml{sup -1}. Initial crystals were obtained by the microbatch method in the presence of a U{sub 10} RNA oligonucleotide and the ATP analog AMP-PNP and were then improved by using seeding and sitting-drop vapor diffusion. A cryocooled crystal of Mss116p/{Delta}598-664 in complex with AMP-PNP and U{sub 10} belonged to space group P2{sub 1}2{sub 1}2, with unit-cell parameters a = 88.54, b = 126.52, c = 55.52 {angstrom}, and diffracted X-rays to beyond 1.9 {angstrom} resolution using synchrotron radiation from sector 21 at the Advanced Photon Source.

  5. X-ray instrumentation in astronomy

    International Nuclear Information System (INIS)

    Cuhlane, J.L.

    1985-01-01

    This book presents the proceedings of a conference devoted to x-ray instrumentation in astronomy. Special sections are: AXAF X-Ray Optical Systems; Specialized X-Ray Systems; X-Ray Optical Systems I; X-Ray Optical Systems II; Gas Filled X-Ray Detectors II; The NASA Advanced X-Ray Astrophysics Facility; X-Ray and EUV Spectrometers; Microchannel Plates; and Solid State Detectors

  6. X-Ray Lasers 2016

    CERN Document Server

    Bulanov, Sergei; Daido, Hiroyuki; Kato, Yoshiaki

    2018-01-01

    These proceedings comprise a selection of invited and contributed papers presented at the 15th International Conference on X-Ray Lasers (ICXRL 2016), held at the Nara Kasugano International Forum, Japan, from May 22 to 27, 2016. This conference was part of an ongoing series dedicated to recent developments in the science and technology of x-ray lasers and other coherent x-ray sources with additional focus on supporting technologies, instrumentation and applications.   The book showcases recent advances in the generation of intense, coherent x-rays, the development of practical devices and their applications across a wide variety of fields. It also discusses emerging topics such as plasma-based x-ray lasers, 4th generation accelerator-based sources and higher harmonic generations, as well as other x-ray generation schemes.

  7. Inhibition of thermolysin and neutral endopeptidase 24.11 by a novel glutaramide derivative: X-ray structure determination of the thermolysin-inhibitor complex.

    Science.gov (United States)

    Holland, D R; Barclay, P L; Danilewicz, J C; Matthews, B W; James, K

    1994-01-11

    Determination of the X-ray structure of thermolysin-inhibitor complexes has proven useful in aiding our understanding of the mode of binding of inhibitors of related, physiologically important, mammalian zinc peptidases including neutral endopeptidase EC 3.4.24.11 and angiotensin-converting enzyme. Here we describe the mode of binding to crystalline thermolysin of N-[1-(2(R,S)-carboxy-4-phenylbutyl)-cyclopentylcarbonyl]-(S) -tryptophan (CCT). CCT is an analogue of both candoxatrilat, a potent inhibitor of neutral endopeptidase 24.11, and of the 5-indanyl ester prodrug candoxatril, which is under clinical evaluation as a potential therapy for congestive heart failure. CCT differs from the previously studied N-carboxyalkyl dipeptide CLT [N-(S)-(1-carboxy-3-phenylpropyl)-(S)-leucyl-(S)-tryptophan] in several important respects. It has a highly constrained gem-cyclopentyl P1' substituent and lacks the characteristic imino nitrogen substituent of CLT. The structure determination shows that, notwithstanding the conformational influence of the gem-cyclopentyl substituent, CCT binds within the active site of thermolysin in a similar manner to CLT. Although the characteristic hydrogen bond between the imino nitrogen of CLT and thermolysin is absent in CCT, the affinities of the two inhibitors for the enzyme are virtually identical. These results illustrate the importance of considering not only those hydrogen bonds that are formed in an enzyme-ligand complex but also the other hydrogen bonds that may be lost due to desolvation of the enzyme and ligand on formation of the complex. In addition, the overall conformational demands placed upon a ligand in order to achieve receptor interaction may be critically important.

  8. Chemical synthesis and X-ray structure of a heterochiral {D-protein antagonist plus vascular endothelial growth factor} protein complex by racemic crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Kalyaneswar; Uppalapati, Maruti; Ault-Riché, Dana; Kenney, John; Lowitz, Joshua; Sidhu, Sachdev S.; Kent, Stephen B.H. (Antibody Solutions); (Toronto); (Reflexion); (UC)

    2012-10-23

    Total chemical synthesis was used to prepare the mirror image (D-protein) form of the angiogenic protein vascular endothelial growth factor (VEGF-A). Phage display against D-VEGF-A was used to screen designed libraries based on a unique small protein scaffold in order to identify a high affinity ligand. Chemically synthesized D- and L- forms of the protein ligand showed reciprocal chiral specificity in surface plasmon resonance binding experiments: The L-protein ligand bound only to D-VEGF-A, whereas the D-protein ligand bound only to L-VEGF-A. The D-protein ligand, but not the L-protein ligand, inhibited the binding of natural VEGF{sub 165} to the VEGFR1 receptor. Racemic protein crystallography was used to determine the high resolution X-ray structure of the heterochiral complex consisting of {l_brace}D-protein antagonist + L-protein form of VEGF-A{r_brace}. Crystallization of a racemic mixture of these synthetic proteins in appropriate stoichiometry gave a racemic protein complex of more than 73 kDa containing six synthetic protein molecules. The structure of the complex was determined to a resolution of 1.6 {angstrom}. Detailed analysis of the interaction between the D-protein antagonist and the VEGF-A protein molecule showed that the binding interface comprised a contact surface area of approximately 800 {angstrom}{sup 2} in accord with our design objectives, and that the D-protein antagonist binds to the same region of VEGF-A that interacts with VEGFR1-domain 2.

  9. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  10. X-ray filtration apparatus

    International Nuclear Information System (INIS)

    Thompson, G.

    1992-01-01

    This invention relates to an X-ray shielding support device. In spite of considerable development in X-ray taking techniques, a need still exists for effective shielding, inter alia, to compensate for variations in the thickness, density and the absorption properties of the object being studied. By appropriate shielding, the X-ray image produced is of sufficient detail, contrast and intensity over its entire area to constitute a useful diagnostic aid. It is also desirable to subject the patient to the smallest possible X-ray dosage. 4 figs

  11. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  12. Anomalous X-Ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Wendin, G.

    1979-01-01

    The availability of tunable synchrotron radiation has made it possible systematically to perform x-ray diffraction studies in regions of anomalous scattering near absorption edges, e.g., in order to derive phase information for crystal structure determination. An overview is given of recent experimental and theoretical work and discussion of the properties of the anomalous atomic scattering factor, with emphasis on threshold resonances and damping effects. The results are applied to a discussion of the very strong anomalous dispersion recently observed near the L3 edge in a cesium complex. Also given is an overview of elements and levels where similar behavior can be expected. Finally, the influence of solid state and chemical effects on the absorption edge structure is discussed. 64 references.

  13. Anomalous x-ray scattering

    International Nuclear Information System (INIS)

    Wendin, G.

    1979-01-01

    The availability of tunable synchrotron radiation has made it possible systematically to perform x-ray diffraction studies in regions of anomalous scattering near absorption edges, e.g. in order to derive phase information for crystal structure determination. An overview is given of recent experimental and theoretical work and discuss the properties of the anomalous atomic scattering factor, with emphasis on threshold resonances and damping effects. The results are applied to a discussion of the very strong anomalous dispersion recently observed near the L 3 edge in a cesium complex. Also given is an overview of elements and levels where similar behavior can be expected. Finally, the influence of solid state and chemical effects on the absorption edge structure is discussed. 64 references

  14. Fast sampling model for X-ray Rayleigh scattering

    CERN Document Server

    Grichine, V M

    2013-01-01

    A simple model for X-ray Rayleigh scattering is discussed in terms of the process total cross-section and the angular distribution of scattered X-ray photons. Comparisons with other calculations and experimental data are presented. The model is optimized for the simulation of X-ray tracking inside experimental setups with complex geometry where performance and memory volume are issues to be optimized. (C) 2013 Elsevier B.V. All rights reserved.

  15. X-ray emission spectroscopy. X-ray fluorescence

    International Nuclear Information System (INIS)

    Despujols, J.

    1992-01-01

    Principles of X-ray emission spectrometry are first recalled, then wave-length dispersive and energy dispersive X-ray fluorescence spectrometer are described. They are essentially designed for qualitative and quantitative analysis of elements (Z>10). Sample preparation, calibration, corrections, interferences, accuracy are reviewed. Examples of use in different industries are given. (71 refs.)

  16. X-ray atlas of rheumatic diseases

    International Nuclear Information System (INIS)

    Dihlmann, W.

    1986-01-01

    This atlas comprises instructive X-rays of the various inflammatory rheumatic joint diseases in all stages at the extremities and the spinal column. In addition, the complex pattern of the wide range of arthroses, also known as degenerative rheumatic disease is included. Besides the instructive pointers to X-ray diagnosis, the book is also a guide to differential diagnosis. Hence, this book is actually an X-ray atlas of joint diseases in general. Selected Contents: Introduction: What Does ''Rheumatism'' Actually Mean?/Radiographic Methodology in Rheumatic Diseases of the Locomotor System/The Mosaic of Arthritis/Adult Rheumatoid Arthritis/Seronegative Spondylarthritis/Classic Collagen Diseases/Enthesiopathies/Gout-Pseudogout

  17. Mn K-edge X-ray absorption studies of oxo- and hydroxo-manganese(IV) complexes: experimental and theoretical insights into pre-edge properties.

    Science.gov (United States)

    Leto, Domenick F; Jackson, Timothy A

    2014-06-16

    Mn K-edge X-ray absorption spectroscopy (XAS) was used to gain insights into the geometric and electronic structures of [Mn(II)(Cl)2(Me2EBC)], [Mn(IV)(OH)2(Me2EBC)](2+), and [Mn(IV)(O)(OH)(Me2EBC)](+), which are all supported by the tetradentate, macrocyclic Me2EBC ligand (Me2EBC = 4,11-dimethyl-1,4,8,11-tetraazabicyclo[6.6.2]hexadecane). Analysis of extended X-ray absorption fine structure (EXAFS) data for [Mn(IV)(O)(OH)(Me2EBC)](+) revealed Mn-O scatterers at 1.71 and 1.84 Å and Mn-N scatterers at 2.11 Å, providing the first unambiguous support for the formulation of this species as an oxohydroxomanganese(IV) adduct. EXAFS-determined structural parameters for [Mn(II)(Cl)2(Me2EBC)] and [Mn(IV)(OH)2(Me2EBC)](2+) are consistent with previously reported crystal structures. The Mn pre-edge energies and intensities of these complexes were examined within the context of data for other oxo- and hydroxomanganese(IV) adducts, and time-dependent density functional theory (TD-DFT) computations were used to predict pre-edge properties for all compounds considered. This combined experimental and computational analysis revealed a correlation between the Mn-O(H) distances and pre-edge peak areas of Mn(IV)═O and Mn(IV)-OH complexes, but this trend was strongly modulated by the Mn(IV) coordination geometry. Mn 3d-4p mixing, which primarily accounts for the pre-edge intensities, is not solely a function of the Mn-O(H) bond length; the coordination geometry also has a large effect on the distribution of pre-edge intensity. For tetragonal Mn(IV)═O centers, more than 90% of the pre-edge intensity comes from excitations to the Mn═O σ* MO. Trigonal bipyramidal oxomanganese(IV) centers likewise feature excitations to the Mn═O σ* molecular orbital (MO) but also show intense transitions to 3dx(2)-y(2) and 3dxy MOs because of enhanced 3d-4px,y mixing. This gives rise to a broader pre-edge feature for trigonal Mn(IV)═O adducts. These results underscore the importance of

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images are easily accessible and are frequently compared to current x-ray images for diagnosis and ... the x-ray film holder or digital recording plate under the table in the area ...

  19. Chandra's X-ray Vision

    Indian Academy of Sciences (India)

    1999-07-23

    Jul 23, 1999 ... GENERAL I ARTICLE. Chandra's X-ray Vision. K P Singh. Chandra X-ray Observatory (CXO) is a scientific satellite (moon/ chandra), named after the Indian-born Nobel laureate. Subrahmanyan Chandrasekhar - one of the foremost astro- physicists of the twentieth century and popularly known as. Chandra.

  20. Traditional x-ray imaging

    International Nuclear Information System (INIS)

    Hay, G.A.

    1982-01-01

    Methods of imaging x-rays, with particular reference to medicine, are reviewed. The history and nature of x-rays, their production and spectra, contrast, shapes and fine structure, image transducers, including fluorescent screens, radiography, fluoroscopy, and image intensifiers, image detection, perception and enhancement and clinical applications are considered. (U.K.)

  1. X-ray based extensometry

    Science.gov (United States)

    Jordan, E. H.; Pease, D. M.

    1988-01-01

    A totally new method of extensometry using an X-ray beam was proposed. The intent of the method is to provide a non-contacting technique that is immune to problems associated with density variations in gaseous environments that plague optical methods. X-rays are virtually unrefractable even by solids. The new method utilizes X-ray induced X-ray fluorescence or X-ray induced optical fluorescence of targets that have melting temperatures of over 3000 F. Many different variations of the basic approaches are possible. In the year completed, preliminary experiments were completed which strongly suggest that the method is feasible. The X-ray induced optical fluorescence method appears to be limited to temperatures below roughly 1600 F because of the overwhelming thermal optical radiation. The X-ray induced X-ray fluorescence scheme appears feasible up to very high temperatures. In this system there will be an unknown tradeoff between frequency response, cost, and accuracy. The exact tradeoff can only be estimated. It appears that for thermomechanical tests with cycle times on the order of minutes a very reasonable system may be feasible. The intended applications involve very high temperatures in both materials testing and monitoring component testing. Gas turbine engines, rocket engines, and hypersonic vehicles (NASP) all involve measurement needs that could partially be met by the proposed technology.

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  4. X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Attekum, P.M.T.M. van.

    1979-01-01

    The methods and results of X-ray photoelectron spectroscopy in the study of plasmons, alloys and gold compounds are discussed. After a comprehensive introduction, seven papers by the author, previously published elsewhere, are reprinted and these cover a wide range of the uses of X-ray photoelectron spectroscopy. (W.D.L.)

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very ... they provide little information about muscles, tendons or joints. An MRI may ...

  6. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic radiography is described in detail. It comprises a tubular target carrier supporting at its distal end a target with an inclined forward face. Image definition is improved by positioning in the path of the X-rays a window of X-ray transmitting ceramic material, e.g. 90% oxide of Be, or Al, 7% Si0 2 . The target carrier forms a probe which can be positioned in the patient's mouth. X-rays are directed forwardly and laterally of the target to an X-ray film positioned externally. The probe is provided with a detachable sleeve having V-form arms of X-ray opaque material which serve to depress the tongue out of the radiation path and also shield the roof of the mouth and other regions of the head from the X-ray pattern. A cylindrical lead shield defines the X-ray beam angle. (author)

  7. Quantitative Imaging of Single, Unstained Viruses with Coherent X Rays

    International Nuclear Information System (INIS)

    Song Changyong; Jiang Huaidong; Mancuso, Adrian; Amirbekian, Bagrat; Miao Jianwei; Peng Li; Sun Ren; Shah, Sanket S.; Zhou, Z. Hong; Ishikawa, Tetsuya

    2008-01-01

    We report the recording and reconstruction of x-ray diffraction patterns from single, unstained viruses, for the first time. By separating the diffraction pattern of the virus particles from that of their surroundings, we performed quantitative and high-contrast imaging of a single virion. The structure of the viral capsid inside a virion was visualized. This work opens the door for quantitative x-ray imaging of a broad range of specimens from protein machineries and viruses to cellular organelles. Moreover, our experiment is directly transferable to the use of x-ray free electron lasers, and represents an experimental milestone towards the x-ray imaging of large protein complexes

  8. Primary cumulus platinum minerals in the Monts de Cristal Complex, Gabon: magmatic microenvironments inferred from high-definition X-ray fluorescence microscopy

    Science.gov (United States)

    Barnes, Stephen J.; Fisher, Louise A.; Godel, Bélinda; Pearce, Mark A.; Maier, Wolfgang D.; Paterson, David; Howard, Daryl L.; Ryan, Christopher G.; Laird, Jamie S.

    2016-03-01

    An unusual occurrence of Pt-enriched pyroxenites in the Monts de Cristal igneous complex is characterized by unusually high ratios of Pt to other platinum-group elements (PGEs) and very low Cu and sulfide contents. Synchrotron X-ray fluorescence microscopy was used to identify over a hundred discrete grains of platinum minerals and relate their occurrence to textural associations in the host heteradcumulate orthopyroxenites. Element associations, backed up by FIB-SEM and PIXE probe observations, indicate that most of the Pt is associated with either As- or trace Cu-Ni-rich sulfides, or both. Some of the Pt-As grains can be identified as sperrylite, and most are likely to be Pt-Fe alloy. The relative abundances and volumes of Pt minerals to sulfide minerals are very large compared with typical magmatic sulfides. Almost all of the grains observed lie at or within a few tens of μm of cumulus orthopyroxene grain boundaries, and there is no significant difference between the populations of grains located inside or outside plagioclase oikocrysts. These oikocrysts are inferred to have crystallized either at the cumulus stage or very shortly thereafter, on the basis of their relationship to Ti enrichment in the margins of pyroxene grains not enclosed in oikocrysts. This relationship precludes a significant role of trapped intercumulus liquid in Pt deposition or mobilization and also allows a confident inference that Pt-rich and Pt-As-enriched phases precipitated directly from the magma at the cumulus stage. These observations lead to the conclusion that fractionation of Pt from other PGEs in this magmatic system is a consequence of a solubility limit for solid Pt metal and/or Pt arsenide.

  9. Determination of crystal and molecular structures of two complexes resulting from the reaction between bis (diethyl muconate) monocarbonyliron and monodentate nitrogenated heterocyclic ligands, by X-ray diffractometry

    International Nuclear Information System (INIS)

    Inumaru, A.T.

    1983-01-01

    The crystal structures of (diethylmuconate) (quinoline) dicarbonyliron and (diethyl muconate) (pyrazine) dicarbonyliron have been determined from diffractometric X-ray data using the heavy atom method. (Diethyl muconate) (quinoline) dicarbonyliron. C 21 H 21 O 6 NFe. Crystal system: triclinic; space group P1 sup(-); a=7.766(2), b=9.664(2), c=14.917(2)A sup(o), α=84.12(2), β=74.99(2), γ=76.54(2) sup(o), V=1050.6(5)A sup(o) 3 , Z=2, D sub(c)=1.382 Mg m -3 , lambda(M sub(o) K sub(α))=0.71073A sup(o), μ(M sub(o) K sub(α))=0.78mm -1 . The final R-factor was 0.058 for 1589 reflections with I>3σ(I). (Diethyl muconate) (pyrazine) dicarbonyliron. C 16 H 18 O 6 N 2 Fe. Crystal system: monoclinic; space group P2 1 /C; a=10.390(2), b=19.754(4), c=9.051(2)A sup(o), β=108.27(2) sup(o), V=1764(1)A sup(o) 3 , Z=4, D sub(c)=1.469 Mg m -3 , lambda(M sub(o) K sub(α))=0.71073A sup(o), μ(M sub(o) K sub(α))=0.98mm -1 . The final R-factor was 0.066 for 967 reflections with I>3σ(I). In both compunds the Fe sup(o) atom is penta coordinated in the form of a quadrangular pyramid, being that the nitrogen atom occupies the apical position in the pyrazine complex and one of the basal positions in the quinolinecase. (Author) [pt

  10. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  11. X-Ray Tomographic Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bonnie Schmittberger

    2010-08-25

    Tomographic scans have revolutionized imaging techniques used in medical and biological research by resolving individual sample slices instead of several superimposed images that are obtained from regular x-ray scans. X-Ray fluorescence computed tomography, a more specific tomography technique, bombards the sample with synchrotron x-rays and detects the fluorescent photons emitted from the sample. However, since x-rays are attenuated as they pass through the sample, tomographic scans often produce images with erroneous low densities in areas where the x-rays have already passed through most of the sample. To correct for this and correctly reconstruct the data in order to obtain the most accurate images, a program employing iterative methods based on the inverse Radon transform was written. Applying this reconstruction method to a tomographic image recovered some of the lost densities, providing a more accurate image from which element concentrations and internal structure can be determined.

  12. Crystallization and preliminary X-ray analysis of a complex formed between the antibiotic simocyclinone D8 and the DNA breakage–reunion domain of Escherichia coli DNA gyrase

    International Nuclear Information System (INIS)

    Edwards, Marcus J.; Flatman, Ruth H.; Mitchenall, Lesley A.; Stevenson, Clare E. M.; Maxwell, Anthony; Lawson, David M.

    2009-01-01

    Crystals of a complex formed between the 59 kDa N-terminal fragment of the E. coli DNA gyrase A subunit and the antibiotic simocyclinone D8 were obtained and X-ray data were recorded to a resolution of 2.75 Å. Crystals of a complex formed between the 59 kDa N-terminal fragment of the Escherichia coli DNA gyrase A subunit (also known as the breakage–reunion domain) and the antibiotic simocyclinone D8 were grown by vapour diffusion. The complex crystallized with I-centred orthorhombic symmetry and X-ray data were recorded to a resolution of 2.75 Å from a single crystal at the synchrotron. DNA gyrase is an essential bacterial enzyme and thus represents an attractive target for drug development

  13. Defining chemical species in complex environments using K-edge X-ray absorption spectroscopy: vanadium in intact blood cells and Henze solution from the tunicate Ascidia ceratodes.

    Science.gov (United States)

    Frank, P; Hodgson, K O

    2000-12-25

    A K-edge X-ray absorption spectrum (XAS) fitting approach has been developed to speciate elements of interest in complex materials and used here to model the storage of biological vanadium within whole blood cells from the tunicate Ascidia ceratodes. The response of the K-edge XAS of solution-phase V(III) to increasing c(sulfate) at constant pH 1.8 produced specific and systematic effects in the preedge transition at 5468.8 eV (preedge transitions: 1s-->4A2 at 5464.9 +/- 0.1 eV, 1s-->4T2 at 5466.9 +/- 0.1 eV, and 1s-->4T1 at 5468.8 +/- 0.1 eV for 11 different V(III)/sulfate solutions). In contrast, variations in acidity (as pH) at constant c(sulfate) systematically modified the V(III) preedge XAS at 5466.9 eV. The energy position of the K-edge absorption maximum also serially shifted -0.32 eV/pH unit, from 5483.7 eV (pH 3.0) to 5484.7 eV (pH 0.3). Fits to the V-K XAS of two samples of A. ceratodes whole blood cells representing dozens of animals implied storage of V(III) ions in four predominant solution regimes: approximately 10% high sulfate/pH 0 acid; approximately 40% high sulfate/pH 1.8 acid; approximately 40% moderate sulfate/pH 1.8 acid; approximately 10% moderate sulfate/pH 3 acid. For lysed blood cells, the best fit represented 63% of the V(III) in a pH 1.6 sulfate-free environment and a further 16% in acidic sulfate solution. Nearly 18% of lysed cells vanadium(III) appeared in a tris(catecholate)-like environment. A detailed speciation of biological vanadium complex ions was calculated from these fits by application of the known equilibrium constants governing V(III) and sulfate in acidic aqueous solution. The utility of blood cell V(III) to ascidians is discussed. Fits to K-edge XAS spectra using the XAS spectra of appropriate models are suggested to be generally applicable to elucidating the state of metal ions in a wide variety of complex environments.

  14. X-ray diffraction and inelastic neutron scattering study of 1:1 tetramethylpyrazine chloranilic acid complex: temperature, isotope, and pressure effects.

    Science.gov (United States)

    Prager, M; Pietraszko, A; Sobczyk, L; Pawlukojć, A; Grech, E; Seydel, T; Wischnewski, A; Zamponi, M

    2006-11-21

    The x-ray diffraction studies of the title complex were carried out at room temperature and 14 K for H/D (in hydrogen bridge) isotopomers. At 82 K a phase transition takes place leading to a doubling of unit cells and alternation of the hydrogen bond lengths linking tetramethylpyrazine (TMP) and chloranilic acid molecules. A marked H/D isotope effect on these lengths was found at room temperature. The elongation is much smaller at 14 K. The infrared isotopic ratio for O-H(D)...N bands equals to 1.33. The four tunnel splittings of methyl librational ground states of the protonated complex required by the structure are determined at a temperature T=4.2 K up to pressures P=4.7 kbars by high resolution neutron spectroscopy. The tunnel mode at 20.6 microeV at ambient pressure shifts smoothly to 12.2 microeV at P=3.4 kbars. This is attributed to an increase of the strength of the rotational potential proportional to r(-5.6). The three other tunnel peaks show no or weak shifts only. The increasing interaction with diminishing intermolecular distances is assumed to be compensated by a charge transfer between the constituents of deltae/e approximately 0.02 kbar(-1). The phase transition observed between 3.4 and 4.7 kbars leads to increased symmetry with only two more intense tunneling bands. In the isotopomer with deuterated hydrogen bonds and P=1 bar all tunnel intensities become equal in consistency with the low temperature crystal structure. The effect of charge transfer is confirmed by a weakening of rotational potentials for those methyl groups whose tunnel splittings were independent of pressure. Density functional theory calculations for the model TMP.(HF)2 complex and fully ionized molecule TMP+ point out that the intramolecular rotational potential of methyl groups is weaker in the charged species. They do not allow for the unequivocal conclusions about the role of the intermolecular charge transfer effect on the torsional frequencies.

  15. TRANSITION PREDICTORS OF X-RAY 0 STAGE FOR KNEE OSTEOARTHRITIS INTO THE 1ST STAGE (BASED ON THE COMPLEX EVALUATION OF THE KNEE JOINT BY MRI WORMS

    Directory of Open Access Journals (Sweden)

    М. V. Makarova

    2017-01-01

    Full Text Available Background. Osteoarthritis (OA is the most common disease among all rheumatological diseases. Approximately 70-80% of all OA cases of are gonarthritis. Routine X-ray examination is not informative to assess non-bone structures. Magnetic resonance imaging (MRI allows visualizing all the structural elements of a joint, such as articular soft tissue structures and subcortical parts. To achieve objective data, the researcher needs to adhere a protocol allowing to assess of all joint parts, the so-called method of evaluation of the whole body (Whole Organ Magnetic Resonance Imaging Score –WORMS. Aim. to determine predictors of OA progression for X-ray 0 stage on the basis of the knee MRI procedure byWORMS.Methods. A cohort study. The sample consisted of patients with gonarthritis in all hospitals inArkhangelsk,Northwest Russia. The main inclusion criterion was clinically confirmed with knee OA by Altman 1991 without X-ray pathological changes. X-ray examinations of the knee joints were performed during the initial diagnosis and after one year. After the first X-ray examination patients underwent an MRI provided by machines with a magnetic field strength of 1.5 Tesla. The study included 76 patients, 22 patients were lost to follow up. Altogether, 54 (71.1% patients completed the study. MRI evaluation of the data was carried out byWORMS protocol.Results. The progression of X-ray 0 stage into the first stage by Kellgren-Lawrence after one year has occurred in 45 (8.3% patients of the 54 patients. Clinically significant predictors of progression of OA of the knee based on MRI were: degeneration of the medial meniscus (OR = 5.0, 95% CI: 1.1-22.5, and synovitis (OR = 7.0, 95% CI: 1.5-33.1, degeneration of the medial meniscus and synovitis were included Regression model. Regression model revealed the most significant predictor of progression of knee OA was synovitis (OR = 5.49, 95% CI: 1.13-26.72. The sensitivity of model was 95,1% (95% CI: 85

  16. Clusters in intense x-ray pulses

    Science.gov (United States)

    Bostedt, Christoph

    2012-06-01

    Free-electron lasers can deliver extremely intense, coherent x-ray flashes with femtosecond pulse length, opening the door for imaging single nanoscale objects in a single shot. All matter irradiated by these intense x-ray pulses, however, will be transformed into a highly-excited non-equilibrium plasma within femtoseconds. During the x-ray pulse complex electron dynamics and the onset of atomic disorder will be induced, leading to a time-varying sample. We have performed first experiments about x-ray laser pulse -- cluster interaction with a combined spectroscopy and imaging approach at both, the FLASH free electron laser in Hamburg (Germany) and the LCLS x-ray free-electron laser in Stanford (California). Atomic clusters are ideal for investigating the light - matter interaction because their size can be tuned from the molecular to the bulk regime, thus allowing to distinguish between intra and inter atomic processes. Imaging experiments with xenon clusters show power-density dependent changes in the scattering patterns. Modeling the scattering data indicates that the optical constants of the clusters change during the femtosecond pulse due to the transient creation of high charge states. The results show that ultra fast scattering is a promising approach to study transient states of matter on a femtosecond time scale. Coincident recording of time-of-flight spectra and scattering patterns allows the deconvolution of focal volume and particle size distribution effects. Single-shot single-particle experiments with keV x-rays reveal that for the highest power densities an highly excited and hot cluster plasma is formed for which recombination is suppressed. Time resolved infrared pump -- x-ray probe experiments have started. Here, the clusters are pumped into a nanoplasma state and their time evolution is probed with femtosecond x-ray scattering. The data show strong variations in the scattering patterns stemming from electronic reconfigurations in the cluster

  17. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  18. X-ray diffraction apparatus

    International Nuclear Information System (INIS)

    Padini, F.R.

    1978-01-01

    The invention provides an x-ray diffraction apparatus permitting the rotation of the divergence sit in conjunction with the rotation of the x-ray irradiated specimen, whereby the dimensions of the x-ray irradiated portion of the specimen remain substantially constant during the rotation of the specimen. In a preferred embodiment, the divergence slit is connected to a structural element linked with a second structural element connected to the specimen such that the divergence slit rotates at a lower angular speed than the specimen

  19. X-ray film calibration

    International Nuclear Information System (INIS)

    Stone, G.F.; Dittmore, C.H.; Henke, B.L.

    1986-01-01

    This paper discusses the use of silver halide x-ray films for imaging and spectroscopy which is limited by the range of intensities that can be recorded and densitometered. Using the manufacturers processing techniques can result in 10 2-3 range in intensity recorded over 0-5 density range. By modifying the chemistry and processing times, ranges of 10 5-6 can be recorded in the same density range. The authors report on x-ray film calibration work and dynamic range improvements. Changes to the processing chemistry and the resulting changes in dynamic range and x-ray sensitivity are discussed

  20. Upsurge of X-ray astronomy 230-

    International Nuclear Information System (INIS)

    Hudec, D.R.

    1978-01-01

    Instruments are described used for X-ray astronomy, namely X-ray detectors and X-ray telescopes. Unlike telescopes, the detectors do not comprise X-ray optics. A survey is given of the results obtained in solar and stellar X-ray astronomy and hypotheses are submitted on the origin of X radiation in the interstellar space. (J.B.)

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... and places the x-ray film holder or digital recording plate under the table in the area ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bone in the body, including the hand, wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg ( ... x-ray tube is connected to a flexible arm that is extended over the patient while an ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to X-ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones ... x-rays involves exposing a part of the body to a small dose of ionizing radiation to ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  7. Flash x-ray cinematography

    International Nuclear Information System (INIS)

    Stein, W.E.

    1976-01-01

    Experiments intended to provide an overview of the potential capabilities and limitations of flash x-ray cinematography as a diagnostic technique for a Fast Reactor Safety Test Facility are described. The results provide estimates of the x-ray pulse intensity required to obtain adequate radiographs of an array of fuel pins in a typical reactor configuration. An estimate of the upper limit on the pulse duration imposed by the reactor background radiation was also determined. X-ray cinematography has been demonstrated at a repetition rate limited only by the recording equipment on hand at the time of these measurements. These preliminary results indicate that flash x-ray cinematography of the motion of fuel in a Fast Reactor Test Facility is technically feasible

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement and fracture reductions. look for injury, ... CT Exams Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety How to Read Your Radiology ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... knee, leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ... information about pregnancy and x-rays. top of page What does the equipment look like? The equipment typically ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  11. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  12. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic dental radiography is described in detail. It comprises an electron gun having an elongated tubular target carrier extending into the patient's mouth. The carrier supports an inclined target for direction of an X-ray pattern towards a film positioned externally of the patient's mouth. Image definition is improved by a focusing anode which focuses the electron beam into a sharp spot (0.05 to 0.10 mm diameter) on the target. The potential on the focusing anode is adjustable to vary the size of the spot. An X-ray transmitting ceramic (oxides of Be, Al and Si) window is positioned adjacent to the front face of the target. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ... or your insurance provider to get a better understanding of the possible charges you will incur. Web ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  15. X-Rays - Multiple Languages

    Science.gov (United States)

    ... Expand Section Barium Swallow - 简体中文 (Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chest X-Ray - 简体中文 (Chinese, Simplified (Mandarin dialect)) ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the ... of the body to a small dose of ionizing radiation to produce pictures of the inside of the ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... appliances, eye glasses and any metal objects or clothing that might interfere with the x-ray images. ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... abnormalities. This exam requires little to no special preparation. Tell your doctor and the technologist if there ... prepare? Most bone x-rays require no special preparation. You will be asked to remove some of ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... in metabolic conditions. assist in the detection and diagnosis of bone cancer . locate foreign objects in soft ... frequently compared to current x-ray images for diagnosis and disease management. top of page How is ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the baby. See the Safety page for more information about pregnancy and x-rays. top of page ... procedure varies. See the Safety page for more information about radiation dose. Women should always inform their ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? A bone x-ray examination itself ... available in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... white on the x-ray, soft tissue shows up in shades of gray and air appears black. ... who will discuss the results with you. Follow-up examinations may be necessary. Your doctor will explain ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the patient in a hospital bed or the emergency room. The x-ray tube is connected to ... equipment is relatively inexpensive and widely available in emergency rooms, physician offices, ambulatory care centers, nursing homes ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in varying degrees. Dense ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... procedure. You may experience discomfort from the cool temperature in the examination room. You may also find ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and ... facilities database . This website does not provide cost information. The costs for specific medical imaging tests, treatments ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... limb, or of a child's growth plate (where new bone is forming), for comparison purposes. When the ... Exams Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety How to Read Your Radiology Report ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... care is taken during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  10. X-ray screening materials

    International Nuclear Information System (INIS)

    Wardley, R.B.

    1981-01-01

    This invention relates to x-ray screening materials and especially to materials in sheet form for use in the production of, for example, protective clothing such as aprons and lower back shields, curtains, mobile screens and suspended shields. The invention is based on the observation that x-ray screening materials in sheet form having greater flexiblity than the hitherto known x-ray screening materials of the same x-ray absorber content can be produced if, instead of using a single sheet of filled sheet material of increased thickness, one uses a plurality of sheets of lesser thickness together forming a laminar material of the desired thickness and one bonds the individual sheets together at their edges and, optionally, at other spaced apart points away from the edges thereby allowing one sheet to move relative to another. (U.K.)

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ensures x-ray image quality. top of page Who interprets the results and how do I get ... report to your primary care or referring physician , who will discuss the results with you. Follow-up ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... no special preparation. Tell your doctor and the technologist if there is any possibility you are pregnant. ... should always inform their physician and x-ray technologist if there is any possibility that they are ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... is commonly used to diagnose fractured bones or joint dislocation. Bone x-rays are the fastest and ... to view and assess bone fractures, injuries and joint abnormalities. This exam requires little to no special ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray ...

  15. Miniature x-ray source

    Science.gov (United States)

    Trebes, James E.; Bell, Perry M.; Robinson, Ronald B.

    2000-01-01

    A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... taking our brief survey: Survey Do you have a personal story about radiology? Share your patient story ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... while the x-ray picture is taken to reduce the possibility of a blurred image. The technologist ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  19. Duodenal X-ray diagnostics

    International Nuclear Information System (INIS)

    Scheppach, W.

    1982-01-01

    The publication provides an overview of duodenal X-ray diagnostics with the aid of barium meals in 1362 patients. The introducing paragraphs deal with the topographic anatomy of the region and the methodics of X-ray investigation. The chapter entitled ''processes at the duodenum itself'' describes mainly ulcers, diverticula, congenital anomalies, tumors and inflammations. The neighbourhood processes comprise in the first place diseases having their origin at the pancreas and bile ducts. As a conclusion, endoscopic rectograde cholangio-pancreaticography and percutaneous transhepatic cholangiography are pointed out as advanced X-ray investigation methods. In the annex of X-ray images some of the described phenomena are shown in exemplary manner. (orig./MG) [de

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in ... injuries, including fractures, and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. A bone x-ray makes images of any ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... radiation dose for this procedure varies. See the Safety page for more information about radiation dose. Women ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... instead of ionizing radiation to create diagnostic images, has also been useful for injuries around joints, and ...

  4. X-ray microscopy of human malaria

    International Nuclear Information System (INIS)

    Magowan, C.; Brown, J.T.; Mohandas, N.; Meyer-Ilse, W.

    1997-01-01

    Associations between intracellular organisms and host cells are complex and particularly difficult to examine. X-ray microscopy provides transmission images of subcellular structures in intact cells at resolutions superior to available methodologies. The spatial resolution is 50-60nm with a 1 micron depth of focus, superior to anything achievable with light microscopy. Image contrast is generated by differences in photoelectric absorption by the atoms in different areas (i.e. subcellular structures) throughout the full thickness of the sample. Absorption due to carbon dominates among all the elements in the sample at 2.4 nm x-ray wavelength. Thus images show features or structures, in a way not usually seen by other types of microscopy. The authors used soft x-ray microscopy to investigate structural development of Plasmodium falciparum malaria parasites in normal and genetically abnormal erythrocytes, and in infected erythrocytes treated with compounds that have anti-malarial effects. X-ray microscopy showed newly elaborated structures in the cytosol of unstained, intact erythrocytes, redistribution of mass (carbon) in infected erythrocytes, and aberrant parasite morphology. Better understanding of the process of intracellular parasite maturation and the interactions between the parasite and its host erythrocyte can help define new approaches to the control of this deadly disease

  5. X-ray microscopy of human malaria

    Energy Technology Data Exchange (ETDEWEB)

    Magowan, C.; Brown, J.T.; Mohandas, N.; Meyer-Ilse, W. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    Associations between intracellular organisms and host cells are complex and particularly difficult to examine. X-ray microscopy provides transmission images of subcellular structures in intact cells at resolutions superior to available methodologies. The spatial resolution is 50-60nm with a 1 micron depth of focus, superior to anything achievable with light microscopy. Image contrast is generated by differences in photoelectric absorption by the atoms in different areas (i.e. subcellular structures) throughout the full thickness of the sample. Absorption due to carbon dominates among all the elements in the sample at 2.4 nm x-ray wavelength. Thus images show features or structures, in a way not usually seen by other types of microscopy. The authors used soft x-ray microscopy to investigate structural development of Plasmodium falciparum malaria parasites in normal and genetically abnormal erythrocytes, and in infected erythrocytes treated with compounds that have anti-malarial effects. X-ray microscopy showed newly elaborated structures in the cytosol of unstained, intact erythrocytes, redistribution of mass (carbon) in infected erythrocytes, and aberrant parasite morphology. Better understanding of the process of intracellular parasite maturation and the interactions between the parasite and its host erythrocyte can help define new approaches to the control of this deadly disease.

  6. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  7. X-ray tube target

    International Nuclear Information System (INIS)

    Weber, R.G.

    1980-01-01

    A target with an improved heat emissive surface for use in a rotating anode type x-ray tube is described. The target consists of a body having a first surface portion made of x-ray emissive material and a second surface portion made of a heat emissive material comprising at least one of hafnium boride, hafnium oxide, hafnium nitride, hafnium silicide, and hafnium aluminide. (U.K.)

  8. X-ray data processing

    OpenAIRE

    Powell, Harold R.

    2017-01-01

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most c...

  9. Center for X-Ray Optics, 1992

    International Nuclear Information System (INIS)

    1993-08-01

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors

  10. Synthetic routes to mixed-ligand cobalt(III) dithiocarbamato complexes containing imidazole, amine and pyridine donors and the X-ray crystal structure of a cobalt(III) bis(dithiocarbamato) histamine complex.

    Science.gov (United States)

    Hodgson, Michael C; Brothers, Penelope J; Clark, George R; Ware, David C

    2008-04-01

    The binuclear cobalt complex [Co(2)(Me(2)dtc)(5)](+) reacts with a range of nitrogen donor ligands L' or L'' to form an equimolar mixture of Co(Me(2)dtc)(3) and the mixed-ligand complexes [Co(Me(2)dtc)(2)(L')(2)](+) or [Co(Me(2)dtc)(2)(L'')](+), where (L')(2) is two monodentate ligands and (L'') is one bidentate ligand. The complexes prepared by this route contain the monodentate ligands L'=1-methyl-imidazole, 1-methyl-5-nitro-imidazole and benzimidazole, all of which coordinate to cobalt through an imidazole nitrogen atom. Symmetrical bidentate ligand complexes contain the bisimidazole L''=2,2'-bis(4,5-dimethylimidazole), the diamine L''=1,2-diaminobenzene and the pyridine donors L''=2,2'-bipyridine, 4,4'-dimethyl-2,2'-bipyridine and 1,10-phenanthroline. Two examples of complexes with unsymmetrical bidentate imidazole-amine donors were prepared in which L''=4-(2-aminoethyl)imidazole (histamine) and 2-aminomethylbenzimidazole. All new complexes were fully characterised, and the X-ray crystal structure of the histamine complex [Co(Me(2)dtc)(2)(hist)]ClO(4) is also reported.

  11. X-ray studies of crystalline complexes involving amino acids and peptides. XLIII. Adipic acid complexes of L- and DL-lysine.

    Science.gov (United States)

    Sharma, Alok; Thamotharan, S; Roy, Siddhartha; Vijayan, M

    2006-03-01

    The asymmetric unit of the DL-lysine complex of adipic acid [bis(DL-lysinium) adipate], 2C6H15N2O2+.C6H8O(4)2-, contains a zwitterionic singly charged lysinium cation and half a doubly charged adipate anion (the complete anion has inversion symmetry). That of the L-lysine complex (lysinium hydrogen adipate), C6H15N2O2+.C6H9O4-, consists of a lysinium cation and a singly charged hydrogen adipate anion. In both structures, the lysinium cations organize into layers interconnected by adipate or hydrogen adipate anions. However, the arrangement of the molecular ions in the layer is profoundly different in the DL- and L-lysine complexes. The hydrogen adipate anions in the L-lysine complex form linear arrays in which adjacent ions are interconnected by a symmetric O...H...O hydrogen bond.

  12. Ultrafast X-ray Sources

    International Nuclear Information System (INIS)

    Neil, George

    2010-01-01

    Since before the scattering of X-rays off of DNA led to the first understanding of the double helix structure, sources of X-rays have been an essential tool for scientists examining the structure and interactions of matter. The resolution of a microscope is proportional to the wavelength of light so x-rays can see much finer structures than visible light, down to single atoms. In addition, the energy of X-rays is resonant with the core atomic levels of atoms so with appropriate wavelengths the placement of specific atoms in a large molecule can be determined. Over 10,000 scientists use synchrotron sources, storage rings of high energy electrons, each year worldwide. As an example of such use, virtually every picture of a protein or drug molecule that one sees in the scientific press is a reconstruction based on X-ray scattering of synchrotron light from the crystallized form of that molecule. Unfortunately those pictures are static and proteins work through configuration (shape) changes in response to energy transfer. To understand how biological systems work requires following the energy flow to these molecules and tracking how shape changes drive their interaction with other molecules. We'd like to be able to freeze the action of these molecules at various steps along the way with an X-ray strobe light. How fast does it have to be? To actually get a picture of a molecule in a fixed configuration requires X-ray pulses as short as 30 femtoseconds (1/30 of a millionth of a millionth of a second). To capture the energy flow through changes in electronic levels requires a faster strobe, less than 1 femtosecond And to acquire such information in smaller samples with higher accuracy demands brighter and brighter X-rays. Unfortunately modern synchrotrons (dubbed 3rd Generation Light Sources) cannot deliver such short bright pulses of X-rays. An entirely new approach is required, linear-accelerator (linac-)-based light sources termed 4th or Next Generation Light Sources

  13. X-ray Echo Spectroscopy

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-01

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >108 ) with broadband ≃5 - 13 meV dispersing systems are introduced featuring more than 103 signal enhancement. The technique is general, applicable in different photon frequency domains.

  14. Complexation of uranyl ions. III. Investigation of the sorption of uranium of the VP-1Ap anion exchanger from carbonate media by x-ray spectrometric microanalysis

    International Nuclear Information System (INIS)

    Komarova, N.I.; Kakhaeva, T.V.; Kvaratskheli, Yu.K.; Vodolazov, L.I.; Rodionov, V.V.

    1987-01-01

    The spatial distribution of uranium in granules of the VP-1Ap anion exchanger during heightened sorption from carbonate media has been investigated by x-ray spectroscopic microanalysis. Variation of the form of the concentration profile as a function of the extent of sorption from a uniform profile across the diameter, then to a meniscus-shaped profile, and finally to a smoothed profile with an increase in the coefficient of nonuniformity of the distribution of uranium in the granules from 0.026 to 0.045 has been established

  15. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    : Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis

  16. Imaging X-ray astronomy

    International Nuclear Information System (INIS)

    Elvis, M.

    1990-01-01

    The launch of the High Energy Astrophysical Observatory, more appealingly called the Einstein Observatory, marked one of the most revolutionary steps taken in astrophysics this century. Its greater sensitivity compared with earlier satellites and its ability to make high spacial and spectral resolution observations transformed X-ray astronomy. This book is based on a Symposium held in Cambridge, Massachusetts, to celebrate a decade of Einstein Observatory's achievements. It discusses the contributions that this satellite has made to each area of modern astrophysics and the diversity of the ongoing work based on Einstein data. There is a guide to each of the main data bases now coming on-line to increase the availability and to preserve this valuable archive for the future. A review of NASA's next big X-ray mission, AXAF, and a visionary program for novel X-ray astronomy satellites by Riccardo Giacconi conclude this wide-ranging volume. (author)

  17. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral X-ray apparatus which reduces the number of exposures necessary to obtain panoramic dental radiographs is described in detail. It comprises an electron gun, a tubular target carrier projecting from the gun along the beam axis and carrying at its distal end a target surrounded by a shield of X-ray opaque material. This shield extends forward and laterally of the target and has surfaces which define a wedge or cone-shaped radiation pattern delimited vertically by the root tips of the patient's teeth. A film holder is located externally of the patient's mouth. A disposable member can fit on the target carrier to depress the patient's tongue out of the radiation pattern and to further shield the roof of the mouth. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  18. X-ray fluorescence holography.

    Science.gov (United States)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu, Wen; Matsushita, Tomohiro

    2012-03-07

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy.

  19. X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu Wen; Matsushita, Tomohiro

    2012-01-01

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy. (topical review)

  20. Crystallization and preliminary X-ray diffraction analysis of a Lys49-phospholipase A2 complexed with caffeic acid, a molecule with inhibitory properties against snake venoms

    International Nuclear Information System (INIS)

    Shimabuku, Patrícia S.; Fernandes, Carlos A. H.; Magro, Angelo J.; Costa, Tássia R.; Soares, Andreimar M.; Fontes, Marcos R. M.

    2011-01-01

    Piratoxin I, a noncatalytic and myotoxic Lys49-phospholipase A 2 from B. pirajai venom, was cocrystallized with the inhibitor caffeic acid and a data set was collected to a resolution of 1.65 Å. The electron-density map unambiguously indicated that three inhibitor molecules interact with the C-terminus of the protein. Phospholipases A 2 (PLA 2 s) are one of the main components of bothropic venoms; in addition to their phospholipid hydrolysis action, they are involved in a wide spectrum of pharmacological activities, including neurotoxicity, myotoxicity and cardiotoxicity. Caffeic acid is an inhibitor that is present in several plants and is employed for the treatment of ophidian envenomations in the folk medicine of many developing countries; as bothropic snake bites are not efficiently neutralized by conventional serum therapy, it may be useful as an antivenom. In this work, the cocrystallization and preliminary X-ray diffraction analysis of the Lys49-PLA 2 piratoxin I from Bothrops pirajai venom in the presence of the inhibitor caffeic acid (CA) are reported. The crystals diffracted X-rays to 1.65 Å resolution and the structure was solved by molecular-replacement techniques. The electron-density map unambiguously indicated the presence of three CA molecules that interact with the C-terminus of the protein. This is the first time a ligand has been observed bound to this region and is in agreement with various experiments previously reported in the literature

  1. X-ray Emission from Solar Flares

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Solar flares; X-ray detectors; X-ray line emission and continuum; break energy; microflares. Abstract. Solar X-ray Spectrometer (SOXS), the first space-borne solar astronomy experiment of India was designed to improve our current understanding of X-ray emission from the Sun in general and solar flares in ...

  2. History of x-ray astronomy

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. History of x-ray astronomy. Major X-ray Missions. 1970 :UHURU: detected 339 new sources (1st sky coverage). 1978: Einstein First x-ray imaging mission (>1000 sources). 1990: ROSAT; Soft X-ray imaging mission; detected 100,000 sources (deeper sky coverage) ...

  3. X-Ray Exam: Cervical Spine

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Cervical Spine KidsHealth / For Parents / X-Ray ... MRI): Lumbar Spine Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  4. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very ... limitations of Chest Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the ...

  5. X-Ray Exam: Neck (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Neck KidsHealth / For Parents / X-Ray Exam: ... Neck Enlarged Adenoids Croup Sinusitis Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  6. Semiconductor X-ray spectrometers

    International Nuclear Information System (INIS)

    Muggleton, A.H.F.

    1978-02-01

    An outline is given of recent developments in particle and photon induced x-ray fluorescence (XRF) analysis. Following a brief description of the basic mechanism of semiconductor detector operation a comparison is made between semiconductor detectors, scintillators and gas filled proportional devices. Detector fabrication and cryostat design are described in more detail and the effects of various device parameters on system performance, such as energy resolution, count rate capability, efficiency, microphony, etc. are discussed. The main applications of these detectors in x-ray fluorescence analysis, electron microprobe analysis, medical and pollution studies are reviewed

  7. Portable X-Ray Device

    Science.gov (United States)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  8. Overutilization of x-rays

    International Nuclear Information System (INIS)

    Abrams, H.L.

    1979-01-01

    In this article on the overutilization of x-rays the author defines the term overutilization as excessive irradiation per unit of diagnostic information, therapeutic impact, or health outcome. Three main factors are described which lead to overutilization of x-rays: excessive radiation per film; excessive films per examination; and excessive examinations per patient. Topics discussed which influence the excessive examinations per patient are: the physician's lack of knowledge; undue dependence; lack of screening by radiologists; the physician's need for action and certainty; patient demand; reimbursement policies; institutional requirements; preventive medicine; defensive medicine; and the practice of radiology by nonradiologists

  9. X-ray data processing.

    Science.gov (United States)

    Powell, Harold R

    2017-10-31

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most commonly used software in the field. © 2017 The Author(s).

  10. X-ray microscopes at BESSY II

    International Nuclear Information System (INIS)

    Guttmann, P.; Niemann, B.; Thieme, J.; Wiesemann, U.; Rudolph, D.; Schmahl, G.

    2000-01-01

    The undulator U41 at BESSY II will be used as source for X-ray microscopes. An overview of the X-ray microscopy area is presented. After finishing the construction phase a transmission X-ray microscope, a scanning transmission X-ray microscope and an X-ray test chamber will be available. The transmission X-ray microscope will allow investigations with high lateral resolution at moderate energy resolution while the scanning transmission X-ray microscope will allow high energy resolution at moderate lateral resolution of the same specimen

  11. Illumination system for X-ray lithography

    International Nuclear Information System (INIS)

    Buckley, W.D.

    1989-01-01

    An X-ray lithography system is described, comprising: a point source of X-Ray radiation; a wafer plane disposed in spaced relation to the point source of X-Ray radiation; a mask disposed between the point source of X-Ray radiation and the wafer plane whereby X-Ray radiation from the point source of X-ray radiation passes through the mask to the water plane; and X-Ray absorbent means mounted between the point source of X-Ray radiation and the wafer plane, the X-Ray absorbent means being of quadratically absorption from maximum absorption at the center to minimum absorption at the edge so as to have a radial absorption gradient profile to compensate for radial flux variation of the X-Ray radiation

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning devices will be used to help you ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) ... imaged receive minimal radiation exposure. top of page ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  14. X-ray tube transformer

    International Nuclear Information System (INIS)

    1980-01-01

    An X-ray generator is described which comprises a transmission line transformer including an electrical conductor with a cavity and a second electrical conductor including helical windings disposed along a longitudinal axis within the cavity of the first conductor. The windings have a pitch which varies per unit length along the axis. There is dielectric material in the cavity for insulation and to couple electromagnetically the two conductors in response to an electric current flowing through the conductors, which have an impedance between them; this varies with distance along the axis of the helix of the second conductor. An X-ray tube is disposed along the longitudinal axis within the cavity, for radiating X-rays. The invention increases the voltage of applied voltage pulses at the remote tube-head with a transformer formed by using a spiral delay line geometry to give a tapered-impedance coaxial high voltage multiplier for pulse voltage operation. This transformer is smaller and lighter than previous designs for the same high peak voltage and power ratings. This is important because the penetration capabilities of Flash X-ray equipment increase with voltage, particularly in heavy materials such as steel. (U.K.)

  15. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of Literature on x-ray fluorescence spectrometry starts with a list of conference proceedings on the subject, organised by the Philips organisation at regular intervals in various European countries. It is followed by a list of bulletins. The bibliography is subdivided according to spectra, equipment, applications and absorption analysis

  16. X-Ray Diffractive Optics

    Science.gov (United States)

    Dennis, Brian; Li, Mary; Skinner, Gerald

    2013-01-01

    X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

  17. X-rays from stars

    Science.gov (United States)

    Güdel, Manuel

    2004-07-01

    Spectroscopic studies available from Chandra and XMM-Newton play a pivotal part in the understanding of the physical processes in stellar (magnetic and non-magnetic) atmospheres. It is now routinely possible to derive densities and to study the influence of ultraviolet radiation fields, both of which can be used to infer the geometry of the radiating sources. Line profiles provide important information on bulk mass motions and attenuation by neutral matter, e.g. in stellar winds. The increased sensitivity has revealed new types of X-ray sources in systems that were thought to be unlikely places for X-rays: flaring brown dwarfs, including rather old, non-accreting objects, and terminal shocks in jets of young stars are important examples. New clues concerning the role of stellar high-energy processes in the modification of the stellar environment (ionization, spallation, etc.) contribute significantly to our understanding of the "astro-ecology" in forming planetary systems. Technological limitations are evident. The spectral resolution has not reached the level where bulk mass motions in cool stars become easily measurable. Higher resolution would also be important to perform X-ray "Doppler imaging" in order to reconstruct the 3-D distribution of the X-ray sources around a rotating star. Higher sensitivity will be required to perform high-resolution spectroscopy of weak sources such as brown dwarfs or embedded pre-main-sequence sources. A new generation of satellites such as Constellation-X or XEUS should pursue these goals.

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... This ensures that those parts of a patient's body not being imaged receive minimal radiation ... x-ray images are among the clearest, most detailed views of ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images ... content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ...

  20. High resolution X ray spectroscopy

    International Nuclear Information System (INIS)

    Bartiromo, R.

    1987-01-01

    This paper is devoted to a detailed discussion of the physical processes which are responsible for the emission spectra of H-like and He-like ion of high Z impurities in low density plasmas. The application of high resolution X-ray spectroscopy to the diagnostic of tokamak plasmas is also discussed and examples of the results obtained are presented

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the equipment look like? How does the procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of Bone X-ray ( ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  4. X-ray image coding

    International Nuclear Information System (INIS)

    1974-01-01

    The invention aims at decreasing the effect of stray radiation in X-ray images. This is achieved by putting a plate between source and object with parallel zones of alternating high and low absorption coefficients for X-radiation. The image is scanned with the help of electronic circuits which decode the signal space coded by the plate, thus removing the stray radiation

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... any possibility that they are pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. A Word About Minimizing ... imaging tests and treatments have special pediatric considerations. The teddy ...

  6. X-rays and magnetism

    International Nuclear Information System (INIS)

    Fischer, Peter; Ohldag, Hendrik

    2015-01-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques. (report on progress)

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used ...

  8. Stellar X-Ray Polarimetry

    Science.gov (United States)

    Swank, J.

    2011-01-01

    Most of the stellar end-state black holes, pulsars, and white dwarfs that are X-ray sources should have polarized X-ray fluxes. The degree will depend on the relative contributions of the unresolved structures. Fluxes from accretion disks and accretion disk corona may be polarized by scattering. Beams and jets may have contributions of polarized emission in strong magnetic fields. The Gravity and Extreme Magnetism Small Explorer (GEMS) will study the effects on polarization of strong gravity of black holes and strong magnetism of neutron stars. Some part of the flux from compact stars accreting from companion stars has been reflected from the companion, its wind, or accretion streams. Polarization of this component is a potential tool for studying the structure of the gas in these binary systems. Polarization due to scattering can also be present in X-ray emission from white dwarf binaries and binary normal stars such as RS CVn stars and colliding wind sources like Eta Car. Normal late type stars may have polarized flux from coronal flares. But X-ray polarization sensitivity is not at the level needed for single early type stars.

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... time. Follow-up examinations are sometimes the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest way for a ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... to current x-ray images for diagnosis and disease management. top of page How is the procedure ...

  11. X-ray absorption holography

    Czech Academy of Sciences Publication Activity Database

    Kopecký, Miloš; Lausi, A.; Bussetto, E.; Kub, Jiří; Savoia, A.

    2002-01-01

    Roč. 88, č. 18 (2002), s. 185503-1 - 185503-3 ISSN 0031-9007 R&D Projects: GA MŠk LN00A100 Institutional research plan: CEZ:AV0Z1010921 Keywords : x-ray holography Subject RIV: BH - Optics, Masers, Lasers Impact factor: 7.323, year: 2002

  12. Compact x-ray source and panel

    Science.gov (United States)

    Sampayon, Stephen E [Manteca, CA

    2008-02-12

    A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

  13. Preparation, spectroscopic studies and X-ray structure of homobinuclear lanthanide(III complexes derived from 2,6-diformyl-4-chlorophénol-bis-(2’-hydroxy-benzoylhydrazone

    Directory of Open Access Journals (Sweden)

    Pepe Marcel Haba

    2006-06-01

    Full Text Available Reaction of the 2,6-diformyl-4-chlorophenol-bis-(2'-hydroxy-benzoylhydrazone with Ln(NO33.nH2O (n = 5 or 6 and Ln = Y, La, Ce, Pr, Nd, Sm, Gd, Dy, Er and Yb produces homobinuclear complexes. These complexes have been characterized by analysis, molar conductance, magnetic measurements, infrared spectral studies and X-ray diffraction. The analytical data showed 1:3 (metal:ligand stoichiometry. Molar conductance measurements in dmf indicate 1:3 electrolytes in all cases. Magnetic moment values are close proximity of the Van Vleck values. IR studies suggest the coordination of the ligand is through the azomethine, the phenolic oxygen atom and the carbonyl oxygen of the hydrazonic moiety. The nitrate ion is also found to be ionic in all the complexes. An X-ray structure determination of [C66H48N12O15Cl3Er2]Cl2NO3.5H2O confirms the conclusion from the spectroscopic studies and show that the erbium is at the centre of a tricapped trigonal prism with coordination number nine. In all the complexes the lanthanide ions have substantially similar coordination.

  14. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  15. Synthesis of 2-deoxy-2,2-difluoro-α-maltosyl fluoride and its X-ray structure in complex with Streptomyces coelicolor GlgEI-V279S

    Energy Technology Data Exchange (ETDEWEB)

    Thanna, Sandeep; Lindenberger, Jared J.; Gaitonde, Vishwanath V.; Ronning, Donald R.; Sucheck, Steven J. (Toledo)

    2015-06-05

    Streptomyces coelicolor (Sco) GlgEI is a glycoside hydrolase involved in α-glucan biosynthesis and can be used as a model enzyme for structure-based inhibitor design targeting Mycobacterium tuberculosis (Mtb) GlgE. The latter is a genetically validated drug target for the development of anti-Tuberculosis (TB) treatments. Inhibition of Mtb GlgE results in a lethal buildup of the GlgE substrate maltose-1-phosphate (M1P). However, Mtb GlgE is difficult to crystallize and affords lower resolution X-ray structures. Sco GlgEI-V279S on the other hand crystallizes readily, produces high resolution X-ray data, and has active site topology identical to Mtb GlgE. We report the X-ray structure of Sco GlgEI-V279S in complex with 2-deoxy-2,2-difluoro-α-maltosyl fluoride (α-MTF, 5) at 2.3 Å resolution. α-MTF was designed as a non-hydrolysable mimic of M1P to probe the active site of GlgE1 prior to covalent bond formation without disruption of catalytic residues. The α-MTF complex revealed hydrogen bonding between Glu423 and the C1F which provides evidence that Glu423 functions as proton donor during catalysis. Further, hydrogen bonding between Arg392 and the axial C2 difluoromethylene moiety of α-MTF was observed suggesting that the C2 position tolerates substitution with hydrogen bond acceptors. The key step in the synthesis of α-MDF was transformation of peracetylated 2-fluoro-maltal 1 into peracetylated 2,2-difluoro-α-maltosyl fluoride 2 in a single step via the use of Selectfluor®

  16. Ab Initio Calculations of X-ray Spectra : Atomic Multiplet and Molecular Orbital Effects in a Multiconfigurational SCF Approach to the L-Edge Spectra of Transition Metal Complexes

    NARCIS (Netherlands)

    Josefsson, Ida; Kunnus, Kristjan; Schreck, Simon; Foehlisch, Alexander; de Groot, Frank; Wernet, Philippe; Odelius, Michael

    2012-01-01

    A new ab initio approach to the calculation of X-ray spectra is demonstrated. It combines a high-level quantum chemical description of the chemical interactions and local atomic multiplet effects. We show here calculated L-edge X-ray absorption (XA) and resonant inelastic X-ray scattering spectra

  17. X-Ray semiotics of cranial involvement in endocrine diseases

    International Nuclear Information System (INIS)

    Spuzyak, M.I.; Kramnoj, I.E.; Belaya, L.M.; Tyazhelova, O.V.; Litvinenko, V.M.

    1992-01-01

    The incidence and type of X-ray semeiotics of the skull involvement were studied in 703 patients with endocrine diseases. Craniorgam analysis involved study of the thickness and structure of the vault bones, shape and size of the skull, status of the sutures, internal plate relief, changes of the base of the skull, of the sella turcica first of all, and facial bone. The characteristic X-ray symprom complexes of the involvement of the skull in some endocrine diseases were distinguished

  18. NuSTAR Hard X-Ray Survey of the Galactic Center Region. II. X-Ray Point Sources

    DEFF Research Database (Denmark)

    Hong, JaeSub; Mori, Kaya; Hailey, Charles J.

    2016-01-01

    We present the first survey results of hard X-ray point sources in the Galactic Center (GC) region by NuSTAR. We have discovered 70 hard (3-79 keV) X-ray point sources in a 0.6 deg2 region around Sgr A* with a total exposure of 1.7 Ms, and 7 sources in the Sgr B2 field with 300 ks. We identify...... persistent luminous X-ray binaries (XBs) and the likely run-away pulsar called the Cannonball. New source-detection significance maps reveal a cluster of hard (>10 keV) X-ray sources near the Sgr. A diffuse complex with no clear soft X-ray counterparts. The severe extinction observed in the Chandra spectra...... indicate that the X-ray spectra of the NuSTAR sources should have kT > 20 keV on average for a single temperature thermal plasma model or an average photon index of Gamma = 1.5-2 for a power-law model. These findings suggest that the GC X-ray source population may contain a larger fraction of XBs with high...

  19. X-ray cardiovascular examination apparatus

    International Nuclear Information System (INIS)

    1977-01-01

    An X-ray source is mounted in an enclosure for angulating longitudinally about a horizontal axis. An X-ray-permeable, patient-supporting table is mounted on the top of the enclosure for executing lateral and longitudinal movements. An X-ray image-receiving device such as an X-ray image intensifier is mounted above the table on a vertically movable arm which is on a longitudinally movable carriage. Electric control means are provided for angulating the X-ray source and image intensifier synchronously as the image intensifier system is shifted longitudinally or vertically such that the central ray from the X-ray source is kept intensifier

  20. Effective X-ray beam size measurements of an X-ray tube and polycapillary X-ray lens system using a scanning X-ray fluorescence method

    Energy Technology Data Exchange (ETDEWEB)

    Gherase, Mihai R., E-mail: mgherase@csufresno.edu; Vargas, Andres Felipe

    2017-03-15

    Size measurements of an X-ray beam produced by an integrated polycapillary X-ray lens (PXL) and X-ray tube system were performed by means of a scanning X-ray fluorescence (SXRF) method using three different metallic wires. The beam size was obtained by fitting the SXRF data with the analytical convolution between a Gaussian and a constant functions. For each chemical element in the wire an effective energy was calculated based on the incident X-ray spectrum and its photoelectric cross section. The proposed method can be used to measure the effective X-ray beam size in XRF microscopy studies.

  1. Center for X-Ray Optics, 1986

    International Nuclear Information System (INIS)

    1987-07-01

    The Center for X-Ray Optics has made substantial progress during the past year on the development of very high resolution x-ray technologies, the generation of coherent radiation at x-ray wavelengths, and, based on these new developments, had embarked on several scientific investigations that would not otherwise have been possible. The investigations covered in this report are topics on x-ray sources, x-ray imaging and applications, soft x-ray spectroscopy, synchrotron radiation, advanced light source and magnet structures for undulators and wigglers

  2. X-ray diagnostic in gas discharge

    International Nuclear Information System (INIS)

    Chen Suhe; Wang Dalun; Cui Gaoxian; Wang Mei; Fu Yibei; Zhang Xinwei; Zhang Wushou

    1995-01-01

    X rays were observed when the anomalous phenomenon in the metal loaded with deuterium studied by the gas-discharge method. Therefore the X-ray energy spectra were measured by the absorption method, the specific X-ray approach and the NaI scintillation counter, while X-ray intensity was estimated by using 7 Li thermoluminescent foils. The X-ray average energy measured by the absorption method is 27.6 +- 2.1 keV, which is fitted within the error extent to 26.0 +-2.4 keV monoenergetic X rays measured by the NaI scintillation counter

  3. X-ray tube arrangements

    International Nuclear Information System (INIS)

    Gillard, R.G.

    1980-01-01

    A technique for ensuring the rapid correction of both amplitude and offset errors in the deflectional movement of an electron beam along an X-ray emissive target is described. The movement is monitored at at least two positions during a sweep and differences, between the two movements and a desired movement, at these positions are combined in different proportions to produce a corrective servo signal. Such arrangements find application, for example, in computerised tomographic scanners. (author)

  4. X-ray Sensitive Material

    Science.gov (United States)

    2015-12-01

    Reference 3), inorganic semiconductors (silicon [Si], cadmium zinc telluride [CdZnTe]) (Reference 4) and selenium (References 5 and 6), Ne-Xe...data showing photocurrent generation. Reports on other X-ray photoconductors, such as amorphous selenium , typically show such data (Reference 34). We...that BiI3 content does contribute to surface discharge; however, further work is warranted to measure the photocurrent. Selenium films used for

  5. Diffractive X-ray Telescopes

    OpenAIRE

    Skinner, Gerald K.

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted space- time in the immediate vicinity of the super...

  6. Smart X-ray optics

    International Nuclear Information System (INIS)

    Michette, A G; Pfauntsch, S J; Sahraei, S; Shand, M; Morrison, G R; Hart, D; Vojnovic, B; Stevenson, T; Parkes, W; Dunare, C; Willingale, R; Feldman, C; Button, T; Zhang, D; Rodriguez-Sanmartin, D; Wang, H

    2009-01-01

    This paper describes reflective adaptive/active optics for applications including studies of biological radiation damage. The optics work on the polycapillary principle, but use arrays of channels in thin silicon. For optimum performance the x-rays should reflect once off a channel wall in each of two successive arrays. This reduces aberrations since then the Abbe sine condition is approximately satisfied. Adaptivity is achieved by flexing the arrays via piezo actuation, providing further aberration reduction and controllable focal length.

  7. X-Ray Crystallography Reagent

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor)

    2003-01-01

    Microcapsules prepared by encapsulating an aqueous solution of a protein, drug or other bioactive substance inside a semi-permeable membrane by are disclosed. The microcapsules are formed by interfacial coacervation under conditions where the shear forces are limited to 0-100 dynes per square centimeter at the interface. By placing the microcapsules in a high osmotic dewatering solution. the protein solution is gradually made saturated and then supersaturated. and the controlled nucleation and crystallization of the protein is achieved. The crystal-filled microcapsules prepared by this method can be conveniently harvested and stored while keeping the encapsulated crystals in essentially pristine condition due to the rugged. protective membrane. Because the membrane components themselves are x-ray transparent, large crystal-containing microcapsules can be individually selected, mounted in x-ray capillary tubes and subjected to high energy x-ray diffraction studies to determine the 3-D smucture of the protein molecules. Certain embodiments of the microcapsules of the invention have composite polymeric outer membranes which are somewhat elastic, water insoluble, permeable only to water, salts, and low molecular weight molecules and are structurally stable in fluid shear forces typically encountered in the human vascular system.

  8. Manganese(II)-azido/thiocyanato complexes of naphthylazoimidazoles: X-ray structures of Mn(β-NaiEt) 2(X) 2 (β-NaiEt = 1-ethyl-2-(naphthyl-β-azo)imidazole; X=N3-, NCS -)

    Science.gov (United States)

    Das, D.; Chand, B. G.; Wu, J. S.; Lu, T.-H.; Sinha, C.

    2007-10-01

    Manganese(II)-naphthylazoimidazole complexes using N3- and NCS - as counter ions are characterized as Mn(β-NaiR) 2(X) 2(β-NaiEt = 1-alkyl-2-(naphthyl-β-azo)imidazole; X=N3-, NCS -). The ligands are unsymmetric N(imidazole), N(azo) chelating agents. The microanalytical, spectral (FT-IR, UV-vis), magnetic (bulk moment and EPR) and electrochemical data establish the structure and composition of the complexes. The single crystal X-ray diffraction studies of Mn(β-NaiEt) 2(N 3) 2 and Mn(β-NaiEt) 2(NCS) 2(β-NaiEt = 1-ethyl-2-(naphthyl-β-azo)imidazole) have confirmed the three dimensional structure of the complexes. Cyclic voltammetry exhibits high potential Mn(III)/Mn(II) couple along with azo reductions. The EPR spectra show usual pattern.

  9. A strong steric hindrance effect on ground state, excited state, and charge separated state properties of a CuI-diimine complex captured by X-ray transient absorption spectroscopy

    DEFF Research Database (Denmark)

    Huang, J.; Mara, M.W.; Stickrath, A.B.

    2014-01-01

    Photophysical and structural properties of a CuI diimine complex with very strong steric hindrance, [CuI(dppS)2]+ (dppS = 2,9-diphenyl-1,10-phenanthroline disulfonic acid disodium salt), are investigated by optical and X-ray transient absorption (OTA and XTA) spectroscopy. The bulky phenylsulfonic...... dynamics and structures as well as those of the charge separated state resulting from the interfacial electron injection from the MLCT state to TiO2 nanoparticles (NPs). The OTA results show the absence of the sub-picosecond component previously assigned as the time constant for flattening, while the two...... of metal complex/semiconductor NP hybrids but also provide guidance for designing efficient CuI diimine complexes with optimized structures for application in solar-to-electricity conversion. This journal is...

  10. Experimental Charge Density in an Oxidized Trinuclear Iron Complex using 15 K Synchrotron and 100 K Conventional Single-Crystal X-ray Diffraction

    International Nuclear Information System (INIS)

    Overgaard, J.; Larsen, F.; Timco, G.; Iversen, B.

    2009-01-01

    The experimental electron density distribution in a crystal consisting of the simplest conceivable trinuclear carboxylate-bridged iron-μ3-oxo dianion with two α-picolinium cations has been determined using both synchrotron (15 K) and conventional (100 K) X-ray diffraction data. The constituent trinuclear oxo-centered molecule consists of six 2-bridging formate groups between the iron pairs, while the axial ligand for all iron atoms is another formate group. The compound {(Fe3O(HCOO)6(HCOO)3)2-·H2O·2(α-CH3NC5H5)+}, ( 1) crystallizes in the monoclinic space group P21/m with charge assisted hydrogen bonds linking the α-picolinium cations to the trinuclear groups. The chemical bonding in the weakly asymmetric Fe3O-core of 1 has been examined through the use of the quantum theory of atoms in molecules, and in combination with experimental d-orbital populations, a significant electron sharing is observed between the Fe atoms and the central oxygen. The central oxygen exhibits clear sp2 hybridization, and the iron atoms have valence shell charge concentrations in all metal-ligand bond directions. The relative bond strengths are evaluated based upon the charge density distribution and found to be in accordance with the geometrical results. Integrated group charges follow expectations from formal chemical valences.

  11. X-RAY HIGH-RESOLUTION SPECTROSCOPY REVEALS FEEDBACK IN A SEYFERT GALAXY FROM AN ULTRA-FAST WIND WITH COMPLEX IONIZATION AND VELOCITY STRUCTURE

    Energy Technology Data Exchange (ETDEWEB)

    Longinotti, A. L. [Catedrática CONACYT—Instituto Nacional de Astrofísica, Óptica y Electrónica, Luis E. Erro 1, Tonantzintla, Puebla, C.P. 72840, México (Mexico); Krongold, Y. [Instituto de Astronomia, Universidad Nacional Autonoma de Mexico, Apartado Postal 70264, 04510 Mexico D.F. (Mexico); Guainazzi, M.; Santos-Lleo, M.; Rodriguez-Pascual, P. [ESAC, P.O. Box, 78 E-28691 Villanueva de la Cañada, Madrid (Spain); Giroletti, M. [INAF Osservatorio di Radioastronomia, via Gobetti 101, I-40129 Bologna (Italy); Panessa, F. [INAF—Istituto di Astrofisica e Planetologia Spaziali di Roma (IAPS), Via del Fosso del Cavaliere 100, I-00133 Roma (Italy); Costantini, E. [SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584 CA Utrecht (Netherlands)

    2015-11-10

    Winds outflowing from active galactic nuclei (AGNs) may carry significant amounts of mass and energy out to their host galaxies. In this paper we report the detection of a sub-relativistic outflow observed in the narrow line Seyfert 1 galaxy IRAS 17020+4544 as a series of absorption lines corresponding to at least five absorption components with an unprecedented wide range of associated column densities and ionization levels and velocities in the range of 23,000–33,000 km s{sup −1}, detected at X-ray high spectral resolution (E/ΔE ∼ 1000) with the ESA's observatory XMM-Newton. The charge states of the material constituting the wind clearly indicate a range of low to moderate ionization states in the outflowing gas and column densities that are significantly lower than observed in highly ionized ultra-fast outflows. We estimate that at least one of the outflow components may carry sufficient energy to substantially suppress star formation and heat the gas in the host galaxy. IRAS 17020+4544 therefore provides an interesting example of feedback by a moderately luminous AGN that is hosted in a spiral galaxy, a case barely envisaged in most evolution models, which often predict that feedback processes take place in massive elliptical galaxies hosting luminous quasars in a post-merger phase.

  12. In-situ Evaluation of Soil Organic Molecules: Functional Group Chemistry Aggregate Structures, Metal and Surface Complexation Using Soft X-Ray

    International Nuclear Information System (INIS)

    Myneni, Satish C.

    2008-01-01

    Organic molecules are common in all Earth surface environments, and their composition and chemistry play an important role in a variety of biogeochemical reactions, such as mineral weathering, nutrient cycling and the solubility and transport of contaminants. However, most of what we know about the chemistry of these molecules comes from spectroscopy and microscopy studies of organic molecules extracted from different natural systems using either inorganic or organic solvents. Although all these methods gave us clues about the composition of these molecules, their composition and structure change with the extraction and the type of ex-situ analysis, their true behavior is less well understood. The goal of this project is to develop synchrotron instrumentation for studying natural organics, and to apply these recently developed synchrotron X-ray spectroscopy and microscopy techniques for understanding the: (1) functional group composition of naturally occurring organic molecules; (2) macromolecular structures of organic molecules; and (3) the nature of interactions of organic molecules with mineral surfaces in different environmental conditions.

  13. Crystallization and preliminary X-ray diffraction analysis of the wild-type haloalkane dehalogenase DhaA and its variant DhaA13 complexed with different ligands.

    Science.gov (United States)

    Stsiapanava, Alena; Chaloupkova, Radka; Fortova, Andrea; Brynda, Jiri; Weiss, Manfred S; Damborsky, Jiri; Smatanova, Ivana Kuta

    2011-02-01

    Haloalkane dehalogenases make up an important class of hydrolytic enzymes which catalyse the cleavage of carbon-halogen bonds in halogenated aliphatic compounds. There is growing interest in these enzymes owing to their potential use in environmental and industrial applications. The haloalkane dehalogenase DhaA from Rhodococcus rhodochrous NCIMB 13064 can slowly detoxify the industrial pollutant 1,2,3-trichloropropane (TCP). Structural analysis of this enzyme complexed with target ligands was conducted in order to obtain detailed information about the structural limitations of its catalytic properties. In this study, the crystallization and preliminary X-ray analysis of complexes of wild-type DhaA with 2-propanol and with TCP and of complexes of the catalytically inactive variant DhaA13 with the dye coumarin and with TCP are described. The crystals of wild-type DhaA were plate-shaped and belonged to the triclinic space group P1, while the variant DhaA13 can form prism-shaped crystals belonging to the orthorhombic space group P2(1)2(1)2(1) as well as plate-shaped crystals belonging to the triclinic space group P1. Diffraction data for crystals of wild-type DhaA grown from crystallization solutions with different concentrations of 2-propanol were collected to 1.70 and 1.26 Å resolution, respectively. A prism-shaped crystal of DhaA13 complexed with TCP and a plate-shaped crystal of the same variant complexed with the dye coumarin diffracted X-rays to 1.60 and 1.33 Å resolution, respectively. A crystal of wild-type DhaA and a plate-shaped crystal of DhaA13, both complexed with TCP, diffracted to atomic resolutions of 1.04 and 0.97 Å, respectively.

  14. X-ray photochemistry of carbon hydride molecular ions.

    Science.gov (United States)

    Puglisi, Alessandra; Miteva, Tsveta; Kennedy, Eugene T; Mosnier, Jean-Paul; Bizau, Jean-Marc; Cubaynes, Denis; Sisourat, Nicolas; Carniato, Stéphane

    2018-02-07

    Hydride molecular ions are key ingredients of the interstellar chemistry since they are precursors of more complex molecules. In regions located near a soft X-ray source these ions may resonantly absorb an X-ray photon which triggers a complex chain of reactions. In this work, we simulate ab initio the X-ray absorption spectrum, Auger decay processes and the subsequent fragmentation dynamics of two hydride molecular ions, namely CH 2 + and CH 3 + . We show that these ions feature strong X-ray absorption resonances which relax through Auger decay within 7 fs. The doubly-charged ions thus formed mostly dissociate into smaller ionic carbon fragments: in the case of CH 2 + , the dominant products are either C + /H + /H or CH + /H + . For CH 3 + , the system breaks primary into CH 2 + and H + , which provides a new route to form CH 2 + near a X-ray source. Furthermore, our simulations provide the branching ratios of the final products formed after the X-ray absorption as well as their kinetic and internal energy distributions. Such data can be used in the chemistry models of the interstellar medium.

  15. Aspergillosis - chest x-ray (image)

    Science.gov (United States)

    ... usually occurs in immunocompromised individuals. Here, a chest x-ray shows that the fungus has invaded the lung ... are usually seen as black areas on an x-ray. The cloudiness on the left side of this ...

  16. Soft x-ray Planetary Imager

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to prototype a soft X-ray Imager for planetary applications that has the sensitivity to observe solar system sources of soft  X-ray emission. A strong...

  17. Stabilized x-ray generator power supply

    International Nuclear Information System (INIS)

    Saha, Subimal; Purushotham, K.V.; Bose, S.K.

    1986-01-01

    X-ray diffraction and X-ray fluorescence analysis are very much adopted in laboratories to determine the type and structure of the constituent compounds in solid materials, chemical composition of materials, stress developed on metals etc. These experiments need X-ray beam of fixed intensity and wave length. This can only be achieved by X-ray generator having highly stabilized tube voltage and tube current. This paper describes how X-ray tube high voltage and electron beam current are stabilized. This paper also highlights generation of X-rays, diffractometry and X-ray fluorescence analysis and their wide applications. Principle of operation for stabilizing the X-ray tube voltage and current, different protection circuits adopted, special features of the mains H.V. transformer and H.T. tank are described in this report. (author)

  18. X-ray electromagnetic application technology

    International Nuclear Information System (INIS)

    2011-01-01

    The investigating committee aimed at research on electromagnetic fields in functional devices and X-ray fibers for efficient coherent X-ray generation and their material science, high-precision manufacturing, particularly for X-ray electromagnetic application technology from January 2006 to December 2008. In this report, we describe our research results, in particular, on the topics of synchrotron radiation and free-electron laser, Saga Synchrotron Project, X-ray waveguides and waveguide-based lens-less hard-X-ray imaging, X-ray nanofocusing for capillaries and zone plates, dispersion characteristics in photonics crystal consisting of periodic atoms for nanometer waveguides, electromagnetic characteristics of grid structures for scattering fields of nano-meter electromagnetic waves and X-rays, FDTD parallel computing of fundamental scattering and attenuation characteristics of X-ray for medical imaging diagnosis, orthogonal relations of electromagnetic fields including evanescent field in dispersive medium. (author)

  19. Development of quantitative x-ray microtomography

    International Nuclear Information System (INIS)

    Deckman, H.W.; Dunsmuir, J.A.; D'Amico, K.L.; Ferguson, S.R.; Flannery, B.P.

    1990-01-01

    The authors have developed several x-ray microtomography systems which function as quantitative three dimensional x-ray microscopes. In this paper the authors describe the evolutionary path followed from making the first high resolution experimental microscopes to later generations which can be routinely used for investigating materials. Developing the instrumentation for reliable quantitative x-ray microscopy using synchrotron and laboratory based x-ray sources has led to other imaging modalities for obtaining temporal and spatial two dimensional information

  20. X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Raman, S.; Sparks, C.J. Jr.

    1978-01-01

    An experimental set-up for x-ray fluorescence analysis with synchrotron radiation was built and installed at the Stanford Synchrotron Radiation Project. X-ray spectra were taken from numerous and varied samples in order to assess the potential of synchrotron radiation as an excitation source for multielement x-ray fluorescence analysis. For many applications, the synchrotron radiation technique is shown to be superior to other x-ray fluorescence methods, especially those employing electrons and protons as excitation sources

  1. Phase-sensitive X-ray imager

    Science.gov (United States)

    Baker, Kevin Louis

    2013-01-08

    X-ray phase sensitive wave-front sensor techniques are detailed that are capable of measuring the entire two-dimensional x-ray electric field, both the amplitude and phase, with a single measurement. These Hartmann sensing and 2-D Shear interferometry wave-front sensors do not require a temporally coherent source and are therefore compatible with x-ray tubes and also with laser-produced or x-pinch x-ray sources.

  2. Element specific X-ray fluorescene microtomography

    OpenAIRE

    Günzler, Til Florian

    2003-01-01

    X-ray fluorescence is widely known as an element-specific scanning analytic tool. It is used in many fields of science and technology and has given major new insights into different problems. The relatively large penetration depth of x rays into matter makes them ideally suited for tomography. The combination of x-ray fluorescence analysis and scanning microtomography, hereafter called x-ray fluorescence microtomography, has been further developed and improved in this work. Employing the newl...

  3. X-ray diagnostics - benefits and risks

    International Nuclear Information System (INIS)

    Bartholomaeus, Melanie

    2016-01-01

    The brochure on benefits and risks of X-ray diagnostics discusses the following issues: X radiation - a pioneering discovery and medical sensation, fundamentals of X radiation, frequency of X-ray examinations in Germany in relation to CT imaging, radiation doses resulting from X-ray diagnostics, benefits of X-ray diagnostics - indication and examples, risks - measures for radiation exposure reductions, avoidance of unnecessary examinations.

  4. High-resolution neutron and X-ray diffraction room-temperature studies of an H-FABP–oleic acid complex: study of the internal water cluster and ligand binding by a transferred multipolar electron-density distribution

    Directory of Open Access Journals (Sweden)

    E. I. Howard

    2016-03-01

    Full Text Available Crystal diffraction data of heart fatty acid binding protein (H-FABP in complex with oleic acid were measured at room temperature with high-resolution X-ray and neutron protein crystallography (0.98 and 1.90 Å resolution, respectively. These data provided very detailed information about the cluster of water molecules and the bound oleic acid in the H-FABP large internal cavity. The jointly refined X-ray/neutron structure of H-FABP was complemented by a transferred multipolar electron-density distribution using the parameters of the ELMAMII library. The resulting electron density allowed a precise determination of the electrostatic potential in the fatty acid (FA binding pocket. Bader's quantum theory of atoms in molecules was then used to study interactions involving the internal water molecules, the FA and the protein. This approach showed H...H contacts of the FA with highly conserved hydrophobic residues known to play a role in the stabilization of long-chain FAs in the binding cavity. The determination of water hydrogen (deuterium positions allowed the analysis of the orientation and electrostatic properties of the water molecules in the very ordered cluster. As a result, a significant alignment of the permanent dipoles of the water molecules with the protein electrostatic field was observed. This can be related to the dielectric properties of hydration layers around proteins, where the shielding of electrostatic interactions depends directly on the rotational degrees of freedom of the water molecules in the interface.

  5. High-resolution neutron and X-ray diffraction room-temperature studies of an H-FABP-oleic acid complex: study of the internal water cluster and ligand binding by a transferred multipolar electron-density distribution.

    Science.gov (United States)

    Howard, E I; Guillot, B; Blakeley, M P; Haertlein, M; Moulin, M; Mitschler, A; Cousido-Siah, A; Fadel, F; Valsecchi, W M; Tomizaki, Takashi; Petrova, T; Claudot, J; Podjarny, A

    2016-03-01

    Crystal diffraction data of heart fatty acid binding protein (H-FABP) in complex with oleic acid were measured at room temperature with high-resolution X-ray and neutron protein crystallography (0.98 and 1.90 Å resolution, respectively). These data provided very detailed information about the cluster of water molecules and the bound oleic acid in the H-FABP large internal cavity. The jointly refined X-ray/neutron structure of H-FABP was complemented by a transferred multipolar electron-density distribution using the parameters of the ELMAMII library. The resulting electron density allowed a precise determination of the electrostatic potential in the fatty acid (FA) binding pocket. Bader's quantum theory of atoms in molecules was then used to study interactions involving the internal water molecules, the FA and the protein. This approach showed H⋯H contacts of the FA with highly conserved hydrophobic residues known to play a role in the stabilization of long-chain FAs in the binding cavity. The determination of water hydrogen (deuterium) positions allowed the analysis of the orientation and electrostatic properties of the water molecules in the very ordered cluster. As a result, a significant alignment of the permanent dipoles of the water molecules with the protein electrostatic field was observed. This can be related to the dielectric properties of hydration layers around proteins, where the shielding of electrostatic interactions depends directly on the rotational degrees of freedom of the water molecules in the interface.

  6. The Beginnings of X-ray Crystallography

    Indian Academy of Sciences (India)

    IAS Admin

    The Beginnings of X-ray Crystallography. A Profile on the Two Braggs. Those were the days when Science was hovering around the wave–particle duality. William. Henry Bragg was toying with the idea that X-rays are particles and the observation made by Max von Laue that X-rays are diffracted by crystals could indeed ...

  7. Center for X-ray Optics, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1989-04-01

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source.

  8. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Femur (Upper Leg) KidsHealth / For Parents / X- ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  9. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... Emitting Products and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin it ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most x- ...

  10. X-Ray Exam: Scoliosis (For Parents)

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Scoliosis KidsHealth / For Parents / X-Ray Exam: Scoliosis What's in this article? What It Is Why ... You Have Questions Print What It Is A scoliosis X-ray is a relatively safe and painless ...

  11. Cryotomography x-ray microscopy state

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-10-26

    An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

  12. Student X-Ray Fluorescence Experiments

    Science.gov (United States)

    Fetzer, Homer D.; And Others

    1975-01-01

    Describes the experimental arrangement for x-ray analysis of samples which involves the following: the radioisotopic x-ray disk source; a student-built fluorescence chamber; the energy dispersive x-ray detector, linear amplifier and bias supply; and a multichannel pulse height analyzer. (GS)

  13. Electron beam parallel X-ray generator

    Science.gov (United States)

    Payne, P.

    1967-01-01

    Broad X ray source produces a highly collimated beam of low energy X rays - a beam with 2 to 5 arc minutes of divergence at energies between 1 and 6 keV in less than 5 feet. The X ray beam is generated by electron bombardment of a target from a large area electron gun.

  14. Total reflection x-ray fluorescence (TXRF)

    International Nuclear Information System (INIS)

    Hockett, R.S.

    1995-01-01

    Total reflection X-Ray Fluorescence (TXRF) is a glancing x-ray analytical technique which is used primarily to measure surface metal contamination on semiconductor substrates. This is a review of Total reflection X-Ray Fluorescence (TXRF) applications for silicon semiconductor processing. In addition, some comments are made about the future of TXRF, and in particular, synchrotron radiation TXRF (SR-TXRF)

  15. Automatic weld joint X-ray inspection

    International Nuclear Information System (INIS)

    Richter, H.U.; Linke, D.; Siems, K.D.; Kruse, H.; Schuetze, E.

    1990-01-01

    A gantry mounted robotic x-ray inspection unit has been developed for the series testing of small and medium sized welded components (pipe bends and nozzles). The unit features computer controlled positioning of the x-ray tube and x-ray image amplifier. Image quality classes 2 and even 1 could be achieved without difficulty. (author)

  16. Synthesis and X-ray structure analysis of a new binuclear Schiff base Co(II) complex with the ligand N,N'-bis(3-methoxysalicylidene)-1,4-butanediamine

    Energy Technology Data Exchange (ETDEWEB)

    Nasr-Esfahani, M., E-mail: m-nasresfahani@iaun.ac.ir [Islamic Azad University, Najafabad Branch, Department of Materials Science and Engineering (Iran, Islamic Republic of)

    2009-12-15

    The title binuclear complex, tris[N,N-bis(3-methoxysalicylidene)-1,4-diaminobutane] dicobalt(II), C{sub 60}H{sub 70}Co{sub 2}N{sub 6}O{sub 15}, was prepared by the reaction of the tetradentate Schiff base ligand bis(3-methoxysalicylidene)-1,4-diaminobutane and Co(CH{sub 3}COO){sub 2} . 4H{sub 2}O in a ethanol solution and structurally characterized by single-crystal X-ray diffraction. This complex has a dinuclear structure where two Co(II) ions are bridged by one N{sup 0},N'-bis(3-methoxysalicylidene)-1,4-diaminobutane. The two Co(II) ions, have two distorted octahedral coordination involving two O and two N atoms.

  17. Multiple heating rate kinetic parameters, thermal, X-ray diffraction studies of newly synthesized octahedral copper complexes based on bromo-coumarins along with their antioxidant, anti-tubercular and antimicrobial activity evaluation

    Science.gov (United States)

    Patel, Ketan S.; Patel, Jiten C.; Dholariya, Hitesh R.; Patel, Kanuprasad D.

    2012-10-01

    Series of new Cu(II) complexes were synthesized by classical thermal technique. The biologically potent ligands (L) were prepared by refluxing 6-brom 3-acetyl coumarin with aldehydes in the presence of piperidine in ethanol. The Cu(II) complexes have been synthesized by mixing an aqueous solution of Cu(NO3)2 in 1:1 molar ratios with ethanolic bidentate ligands and Clioquinol. The structures of the ligands and their copper complexes were investigated and confirmed by the elemental analysis, FT-IR, 1H NMR, 13C NMR, mass spectral and powder X-ray diffraction studies respectively. Thermal behaviour of newly synthesized mixed ligand Cu(II) complexes were investigated by means of thermogravimetry, differential thermogravimetry, differential scanning calorimetry, electronic spectra and magnetic measurements. Dynamic scan of DSC experiments for Cu(II) complexes were taken at different heating rates (2.5-20 °C min-1). Kinetic parameters for second step degradation of all complexes obtained by Kissinger's and Ozawa's methods were in good agreement. On the basis of these studies it is clear that ligands coordinated to metal atom in a monobasic bidentate mode, by Osbnd O and Osbnd N donor system. Thus, suitable octahedral geometry for hexa-coordinated state has been suggested for the metal complexes. Both the ligands as well as its complexes have been screened for their in vitro antioxidant, anti-tubercular and antimicrobial activities. All were found to be significant potent compared to parent ligands employed for complexation.

  18. Pulsating X-ray sources

    International Nuclear Information System (INIS)

    Trumper, J.

    1986-01-01

    The discovery of pulsating X-ray sources in close binary systems was one of the major achievements of the Uhuru satellite. Today one knows about two dozens of these sources with pulsational periods between 69 ms and 835 s. In most cases the X-ray source orbits an early-type star of high mass having a rather large optical luminosity. There are a few exceptions: GX1+4 is associated with a late-type (M6) giant, 4U1616-67 has a comparison of very low mass (≤ 0.1 M/sub sub solar/), and Her X-1 is a borderline case, since its counterpart HZ Her is an A-F star of -- 2/sub sub solar/. It is clear that the X-ray sources in these systems are rotating magnetized neutron stars accreting from their normal companion, probably in most cases via Roche lobe overflow which leads to the formation of an accretion disk. In some cases (e.g. Vela X-1) the accretion proceeds via a stellar wind. Pulsations occur because in the immediate vicinity of the neutron star the matter is funneled by the strong magnetic field onto the polar caps where a hot and very luminous plasma is formed. Typical luminosities are huge, namely of the order of 10/sup 37/ erg/s which are radiated at effective temperatures of -- 10/sup 8/ K. Much has been learned about these systems and about neutron stars from studies of pulse arrival times and source spectra. The author briefly summarizes some of the major results and discusses some very recent results obtained with EXOSAT

  19. Protonium X-ray spectroscopy

    CERN Document Server

    Gotta, D

    1999-01-01

    The Lyman and Balmer transitions from antiprotonic hydrogen and deuterium were studied extensively at the low-energy-antiproton ring LEAR at CERN in order to determine the strong interaction effects. A first series of experiments $9 was performed with semiconductor and gaseous X-ray detectors. In the last years of LEAR operation using a Bragg crystal spectrometer, strong interaction parameters in the 2p states of antiprotonic hydrogen and deuterium were measured $9 directly. The results of the measurements support the meson-exchange models describing the medium and long range part of the nucleon-antinucleon interaction. (39 refs).

  20. X-ray intensifying screens

    International Nuclear Information System (INIS)

    Bossomaier, T.R.J.; Sangway, P.C.

    1979-01-01

    It is claimed that stabilization of X-ray intensifying screens against discolouration and hydrolysis of lanthanum or gadolinium oxyhalide phosphors can be achieved by incorporating into the phosphor/binder formulation a compound containing free epoxy groups. Suitable epoxy compounds include gamma glycidoxy trimethoxy silane and dimethyl di(m-glycidoxy methylphenyl) methane. The oxyhalide may be activated by Tb, Tm or Yb and may be mixed with other phosphors. Plasticisers and organo-tin stabilisers for the formulation are given. Many binders are specified, preferably these should not react with the free epoxy groups. (UK)

  1. MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

    Science.gov (United States)

    Zimmerman, Wayne; Blake, Dave; Harris, William; Morookian, John Michael; Randall, Dave; Reder, Leonard J.; Sarrazin, Phillipe

    2013-01-01

    This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

  2. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2015-03-10

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  3. Picosecond x-ray streak camera studies

    International Nuclear Information System (INIS)

    Kasyanov, Yu.S.; Malyutin, A.A.; Richardson, M.C.; Chevokin, V.K.

    1975-01-01

    Some initial results of direct measurement of picosecond x-ray emission from laser-produced plasmas are presented. A PIM-UMI 93 image converter tube, incorporating an x-ray sensitive photocathode, linear deflection, and three stages of image amplification was used to analyse the x-ray radiation emanating from plasmas produced from solid Ti targets by single high-intensity picosecond laser pulses. From such plasmas, the x-ray emission typically persisted for times of 60psec. However, it is shown that this detection system should be capable of resolving x-ray phenomena of much shorter duration. (author)

  4. Si(Li) X-ray detector

    International Nuclear Information System (INIS)

    Yuan Xianglin; Li Zhiyong; Hong Xiuse

    1990-08-01

    The fabrication technology of the 10∼80 mm 2 Si(Li) X-ray detectors are described and some problems concerning technology and measurement are discussed. The specifications of the detectors are shown as well. The Si(Li) X-ray detector is a kind of low energy X-ray detectors. Owing to very high energy resolution, fine linearity and high detection efficiency in the range of low energy X-rays, it is widely used in the fields of nuclear physics, medicine, geology and environmental protection, etc,. It is also a kernel component for the scanning electron microscope and X-ray fluorescence analysis systems

  5. NIKOLA TESLA AND THE X-RAY

    OpenAIRE

    Rade R. Babic

    2005-01-01

    After professor Wilhelm Konrad Röntgen published his study of an x-ray discovery (Academy Bulletin, Berlin, 08. 11. 1895.), Nikola Tesla published his first study of an x-ray on the 11th of March in 1896. (X-ray, Electrical Review). Until the 11th of August in 1897 he had published ten studies on this subject. All Tesla,s x-ray studies were experimental, which is specific to his work. Studying the nature of the x-ray, he established a new medical branch-radiology. He wrote:” There’s no doubt...

  6. Miniature x-ray point source for alignment and calibration of x-ray optics

    International Nuclear Information System (INIS)

    Price, R.H.; Boyle, M.J.; Glaros, S.S.

    1977-01-01

    A miniature x-ray point source of high brightness similar to that of Rovinsky, et al. is described. One version of the x-ray source is used to align the x-ray optics on the Argus and Shiva laser systems. A second version is used to determine the spatial and spectral transmission functions of the x-ray optics. The spatial and spectral characteristics of the x-ray emission from the x-ray point source are described. The physical constraints including size, intensity and thermal limitations, and useful lifetime are discussed. The alignment and calibration techniques for various x-ray optics and detector combinations are described

  7. X-ray and gamma radiography devices

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    When we are using this technique, we also must familiar with the device and instrument that used such as gamma projector, crawler, x-ray tubes and others. So this chapter discussed detailed on device used for radiography work. For the x-ray and gamma, their characteristics are same but the source to produce is a big different. X-ray produced from the machine meanwhile, gamma produce from the source such as Co-60 and IR-192. Both are electromagnetic waves. So, the reader can have some knowledge on what is x-ray tube, discrete x-ray and characteristic x-ray, how the machine works and how to control a machine, what is source for gamma emitter, how to handle the projector and lastly difference between x-ray and gamma. Of course this cannot be with the theory only, so detailed must be learned practically.

  8. X ray imaging microscope for cancer research

    Science.gov (United States)

    Hoover, Richard B.; Shealy, David L.; Brinkley, B. R.; Baker, Phillip C.; Barbee, Troy W., Jr.; Walker, Arthur B. C., Jr.

    1991-01-01

    The NASA technology employed during the Stanford MSFC LLNL Rocket X Ray Spectroheliograph flight established that doubly reflecting, normal incidence multilayer optics can be designed, fabricated, and used for high resolution x ray imaging of the Sun. Technology developed as part of the MSFC X Ray Microscope program, showed that high quality, high resolution multilayer x ray imaging microscopes are feasible. Using technology developed at Stanford University and at the DOE Lawrence Livermore National Laboratory (LLNL), Troy W. Barbee, Jr. has fabricated multilayer coatings with near theoretical reflectivities and perfect bandpass matching for a new rocket borne solar observatory, the Multi-Spectral Solar Telescope Array (MSSTA). Advanced Flow Polishing has provided multilayer mirror substrates with sub-angstrom (rms) smoothnesss for the astronomical x ray telescopes and x ray microscopes. The combination of these important technological advancements has paved the way for the development of a Water Window Imaging X Ray Microscope for cancer research.

  9. Submicron X-ray diffraction

    International Nuclear Information System (INIS)

    MacDowell, Alastair; Celestre, Richard; Tamura, Nobumichi; Spolenak, Ralph; Valek, Bryan; Brown, Walter; Bravman, John; Padmore, Howard; Batterman, Boris; Patel, Jamshed

    2000-01-01

    At the Advanced Light Source in Berkeley the authors have instrumented a beam line that is devoted exclusively to x-ray micro diffraction problems. By micro diffraction they mean those classes of problems in Physics and Materials Science that require x-ray beam sizes in the sub-micron range. The instrument is for instance, capable of probing a sub-micron size volume inside micron sized aluminum metal grains buried under a silicon dioxide insulating layer. The resulting Laue pattern is collected on a large area CCD detector and automatically indexed to yield the grain orientation and deviatoric (distortional) strain tensor of this sub-micron volume. A four-crystal monochromator is then inserted into the beam, which allows monochromatic light to illuminate the same part of the sample. Measurement of diffracted photon energy allows for the determination of d spacings. The combination of white and monochromatic beam measurements allow for the determination of the total strain/stress tensor (6 components) inside each sub-micron sized illuminated volume of the sample

  10. Portable X-ray reflectometer using a low power polychromatic X-ray tube

    International Nuclear Information System (INIS)

    Ohnishi, Tsunemasa; Imashuku, Susumu; Yuge, Koretaka; Kawai, Jun; Shimura, Naomi

    2014-01-01

    We developed a portable X-ray reflectometer which measures energy dispersive X-ray reflectivity using a polychromatic X-rays from a low power (a few watts) X-ray tube and a silicon drift detector. A thin Cu film on silicon substrate using the portable reflectometer was measured. A fringe pattern was shifted due to the change of the X-ray incident angle. The measured peak position of the fringe pattern was satisfactorily agreed with the calculation. (author)

  11. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics

    OpenAIRE

    Sun, Tianxi; MacDonald, C. A.

    2013-01-01

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens.

  12. Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

    Science.gov (United States)

    Koshti, Ajay M.

    2014-01-01

    Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

  13. X-ray backscatter radiography. Intrusive instead of penetrating, X-ray shadow phenomenon

    International Nuclear Information System (INIS)

    Wrobel, Norma; Kolkoori, Sanjeevareddy; Osterloh, Kurt; European Federation for Non-Destructive Testing

    2013-01-01

    Generally, the primary practical advantage of X-ray backscattering radiography is that there is no need to place a detector on the side of the specimen opposite to the source. Such a situation usually is encountered whenever the specimen is not only standing right in front of a wall or even inside a wall but also if the specimen is such big that radiography is not possible because of the layer thickness to be penetrated. The method used here differs fundamentally from the conventional method to interrogate the object with a scanning beam ('pencil beam') and to collect the whole backscattered radiation from the area. The object is fully illuminated by a (uncollimated) cone beam. Here, the image is recorded with a camera of absorbent material (tungsten, lead), which contains a matrix detector as the image receiver. The optical effect is generated by a special twisted slit collimator which operates according to an extended pinhole camera. The independent positioning of source and camera allows a variable irradiation geometry which causes different images as a result. As a consequence, a complex object in front of a backscattering wall appears completely different than standing alone. So X-ray backscatter images have to be interpreted according to their illumination with X-rays and their surroundings. (orig.)

  14. Crystallization and preliminary X-ray analysis of birch-pollen allergen Bet v 1 in complex with a murine monoclonal IgG Fab' fragment

    DEFF Research Database (Denmark)

    Spangfort, M D; Mirza, Osman Asghar; Gajhede, M

    1999-01-01

    of the clinical symptoms of allergy. In order to study the structural basis of allergen-antibody interaction, a complex between the major birch-pollen allergen Bet v 1 and a Fab' fragment isolated from the murine monoclonal Bet v 1 antibody BV16 has been crystallized. Complex crystals belong to space group P1...

  15. Synthesis and X-ray crystal structure of a novel organometallic (µ(3)-oxido)(µ(3)-imido) trinuclear iridium complex

    DEFF Research Database (Denmark)

    Schau-Magnussen, Magnus; Malcho, Phillip; Herbst, Konrad

    2011-01-01

    Reaction of the organometallic aqua ion [Cp*Ir(H(2)O)(3)](2+) with tert-butyl(trimethylsilyl)amine in acetone yielded a novel trinuclear (µ(3)-oxido)(µ(3)-imido)pentamethylcyclopentadienyliridium(iii) complex, [(Cp*Ir)(3)(O)(N(t)Bu)](2+). Single crystal structure analyses show the complex can be ...

  16. Diffractive X-Ray Telescopes

    International Nuclear Information System (INIS)

    Skinner, G.K.; Skinner, G.K

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro arc seconds or even better, that would allow, for example, imaging of the distorted spacetime in the immediate vicinity of the supermassive black holes in the center of active galaxies What then is precluding their immediate adoption Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed atmospheric absorption

  17. Crystallization and preliminary X-ray diffraction analysis of the wild-type haloalkane dehalogenase DhaA and its variant DhaA13 complexed with different ligands

    International Nuclear Information System (INIS)

    Stsiapanava, Alena; Chaloupkova, Radka; Fortova, Andrea; Brynda, Jiri; Weiss, Manfred S.; Damborsky, Jiri; Kuta Smatanova, Ivana

    2011-01-01

    Crystals of the wild-type haloalkane dehalogenase DhaA derived from R. rhodochrous NCIMB 13064 and of its catalytically inactive variant DhaA13 were grown in the presence of various ligands and diffraction data were collected to high and atomic resolution. Haloalkane dehalogenases make up an important class of hydrolytic enzymes which catalyse the cleavage of carbon–halogen bonds in halogenated aliphatic compounds. There is growing interest in these enzymes owing to their potential use in environmental and industrial applications. The haloalkane dehalogenase DhaA from Rhodococcus rhodochrous NCIMB 13064 can slowly detoxify the industrial pollutant 1,2,3-trichloropropane (TCP). Structural analysis of this enzyme complexed with target ligands was conducted in order to obtain detailed information about the structural limitations of its catalytic properties. In this study, the crystallization and preliminary X-ray analysis of complexes of wild-type DhaA with 2-propanol and with TCP and of complexes of the catalytically inactive variant DhaA13 with the dye coumarin and with TCP are described. The crystals of wild-type DhaA were plate-shaped and belonged to the triclinic space group P1, while the variant DhaA13 can form prism-shaped crystals belonging to the orthorhombic space group P2 1 2 1 2 1 as well as plate-shaped crystals belonging to the triclinic space group P1. Diffraction data for crystals of wild-type DhaA grown from crystallization solutions with different concentrations of 2-propanol were collected to 1.70 and 1.26 Å resolution, respectively. A prism-shaped crystal of DhaA13 complexed with TCP and a plate-shaped crystal of the same variant complexed with the dye coumarin diffracted X-rays to 1.60 and 1.33 Å resolution, respectively. A crystal of wild-type DhaA and a plate-shaped crystal of DhaA13, both complexed with TCP, diffracted to atomic resolutions of 1.04 and 0.97 Å, respectively

  18. Rockets for Extended Source Soft X-ray Spectroscopy

    Science.gov (United States)

    McEntaffer, Randall

    The soft X-ray background surrounds our local galactic environment yet very little is known about the physical characteristics of this plasma. A high-resolution spectrum could unlock the properties of this million degree gas but the diffuse, low intensity nature of the background have made it difficult to observe, especially with a dispersive spectrograph. Previous observations have relied on X-ray detector energy resolution which produces poorly defined spectra that are poorly fit by complex plasma models. Here we propose a series of suborbital rocket flights that will begin the characterization of this elusive source through high-resolution X-ray grating spectroscopy. The rocket-based spectrograph can resolve individual emission lines over the soft X-ray band and place tight constraints on the temperature, density, abundance, ionization state and age of the plasma. These payloads will draw heavily from the heritage gained from previous rocket missions, while also benefiting from related NASA technology development programs. The Pennsylvania State University (PSU) team has a history of designing and flying spectrometer components onboard rockets while also being scientific leaders in the field of diffuse soft X-ray astronomy. The PSU program will provide hands-on training of young scientists in the techniques of instrumental and observational X-ray astronomy. The proposed rocket program will also expose these researchers to a full experiment cycle: design, fabrication, tolerance analysis, assembly, flight-qualification, calibration, integration, launch, and data analysis; using a combination of technologies suitable for adaptation to NASA's major missions. The PSU program in suborbital X-ray astronomy represents an exciting mix of compelling science, heritage, cutting-edge technology development, and training of future scientists.

  19. Copper(II) and molybdenum(VI) complexes of a tridentate ONN donor isothiosemicarbazone: synthesis, characterization, X-ray, TGA and DFT

    Czech Academy of Sciences Publication Activity Database

    Fasihizad, A.; Akbari, A.; Ahmadi, M.; Dušek, Michal; Henriques, Margarida Isabel Sousa; Pojarová, Michaela

    2016-01-01

    Roč. 115, Sep (2016), s. 297-305 ISSN 0277-5387 R&D Projects: GA ČR(CZ) GA14-03276S; GA MŠk LO1603 EU Projects: European Commission(XE) CZ.2.16/3.1.00/24510 Institutional support: RVO:68378271 Keywords : isothiosemicarbazone * Copper(II) complex * molybdenum(VI) complex * crystal structure * DFT Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.926, year: 2016

  20. Sensors for x-ray astronomy satellite

    International Nuclear Information System (INIS)

    Makino, Fumiyoshi; Kondo, Ichiro; Nishioka, Yonero; Kameda, Yoshihiko; Kubo, Masaki.

    1980-01-01

    For the purpose of observing the cosmic X-ray, the cosmic X-ray astronomy satellite (CORSA-b, named ''Hakucho'', Japanese for cygnus,) was launched Feb. 21, 1979 by Institute of Space and Aeronautical Science, University of Tokyo. The primary objectives of the satellite are: to perform panoramic survey of the space for X-ray bursts and to perform the spectral and temporal measurement of X-ray sources. The very soft X-ray sensor for X-ray observation and the horizon sensor for spacecraft attitude sensing were developed by Toshiba Corporation under technical support by University of Tokyo and Nagoya University for ''Hakucho''. The features of these sensors are outlined in this paper. (author)