WorldWideScience

Sample records for times prehyperpnea baseline

  1. Analysis of Seasonal Signal in GPS Short-Baseline Time Series

    Science.gov (United States)

    Wang, Kaihua; Jiang, Weiping; Chen, Hua; An, Xiangdong; Zhou, Xiaohui; Yuan, Peng; Chen, Qusen

    2018-04-01

    Proper modeling of seasonal signals and their quantitative analysis are of interest in geoscience applications, which are based on position time series of permanent GPS stations. Seasonal signals in GPS short-baseline (paper, to better understand the seasonal signal in GPS short-baseline time series, we adopted and processed six different short-baselines with data span that varies from 2 to 14 years and baseline length that varies from 6 to 1100 m. To avoid seasonal signals that are overwhelmed by noise, each of the station pairs is chosen with significant differences in their height (> 5 m) or type of the monument. For comparison, we also processed an approximately zero baseline with a distance of pass-filtered (BP) noise is valid for approximately 40% of the baseline components, and another 20% of the components can be best modeled by a combination of the first-order Gauss-Markov (FOGM) process plus white noise (WN). The TEM displacements are then modeled by considering the monument height of the building structure beneath the GPS antenna. The median contributions of TEM to the annual amplitude in the vertical direction are 84% and 46% with and without additional parts of the monument, respectively. Obvious annual signals with amplitude > 0.4 mm in the horizontal direction are observed in five short-baselines, and the amplitudes exceed 1 mm in four of them. These horizontal seasonal signals are likely related to the propagation of daily/sub-daily TEM displacement or other signals related to the site environment. Mismodeling of the tropospheric delay may also introduce spurious seasonal signals with annual amplitudes of 5 and 2 mm, respectively, for two short-baselines with elevation differences greater than 100 m. The results suggest that the monument height of the additional part of a typical GPS station should be considered when estimating the TEM displacement and that the tropospheric delay should be modeled cautiously, especially with station pairs with

  2. Parametric estimation of time varying baselines in airborne interferometric SAR

    DEFF Research Database (Denmark)

    Mohr, Johan Jacob; Madsen, Søren Nørvang

    1996-01-01

    A method for estimation of time varying spatial baselines in airborne interferometric synthetic aperture radar (SAR) is described. The range and azimuth distortions between two images acquired with a non-linear baseline are derived. A parametric model of the baseline is then, in a least square...... sense, estimated from image shifts obtained by cross correlation of numerous small patches throughout the image. The method has been applied to airborne EMISAR imagery from the 1995 campaign over the Storstrommen Glacier in North East Greenland conducted by the Danish Center for Remote Sensing. This has...... reduced the baseline uncertainties from several meters to the centimeter level in a 36 km scene. Though developed for airborne SAR the method can easily be adopted to satellite data...

  3. Accounting for baseline differences and measurement error in the analysis of change over time.

    Science.gov (United States)

    Braun, Julia; Held, Leonhard; Ledergerber, Bruno

    2014-01-15

    If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy. Copyright © 2013 John Wiley & Sons, Ltd.

  4. Mobile Robots Path Planning Using the Overall Conflict Resolution and Time Baseline Coordination

    Directory of Open Access Journals (Sweden)

    Yong Ma

    2014-01-01

    Full Text Available This paper aims at resolving the path planning problem in a time-varying environment based on the idea of overall conflict resolution and the algorithm of time baseline coordination. The basic task of the introduced path planning algorithms is to fulfill the automatic generation of the shortest paths from the defined start poses to their end poses with consideration of generous constraints for multiple mobile robots. Building on this, by using the overall conflict resolution, within the polynomial based paths, we take into account all the constraints including smoothness, motion boundary, kinematics constraints, obstacle avoidance, and safety constraints among robots together. And time baseline coordination algorithm is proposed to process the above formulated problem. The foremost strong point is that much time can be saved with our approach. Numerical simulations verify the effectiveness of our approach.

  5. An application of the baseline correction technique for correcting distorted seismic acceleration time histories

    International Nuclear Information System (INIS)

    Lee, Gyu Mahn; Kim, Jong Wook; Jeoung, Kyeong Hoon; Kim, Tae Wan; Park, Keun Bae; Kim, Keung Koo

    2008-03-01

    Three kinds of baseline correction techniques named as 'Newmark', 'Zero-VD' and 'Newmark and Zero-VD' were introduced to correct the distorted physical characteristics of a seismic time history accelogram. The corrected seismic accelerations and distorted raw acceleration showed an identical response spectra in frequency domains, but showed various time history profiles in velocity and displacement domains. The referred correction techniques were programmed with UNIX-HP Fortran. The verification of the baseline corrected seismic data in terms of frequency response spectrum were performed by ANSYS of a commerical FEM software

  6. Baseline simple and complex reaction times in female compared to male boxers.

    Science.gov (United States)

    Bianco, M; Ferri, M; Fabiano, C; Giorgiano, F; Tavella, S; Manili, U; Faina, M; Palmieri, V; Zeppilli, P

    2011-06-01

    The aim of the study was to compare baseline cognitive performance of female in respect to male amateur boxers. Study population included 28 female amateur boxers. Fifty-six male boxers, matched for age, employment and competitive level to female athletes, formed the control group. All boxers had no history of head concussions (except boxing). Each boxer was requested to: 1) fulfill a questionnaire collecting demographic data, level of education, occupational status, boxing record and number of head concussions during boxing; 2) undergo a baseline computerized neuropsychological (NP) test (CogSport) measuring simple and complex reaction times (RT). Female were lighter than male boxers (56±7 vs. 73.1±9.8 kg, Pknock-outs, etc.) correlated with NP scores. Female and male Olympic-style boxers have no (or minimal) differences in baseline cognitive performance. Further research with larger series of female boxers is required to confirm these findings.

  7. A Baseline-Free Defect Imaging Technique in Plates Using Time Reversal of Lamb Waves

    International Nuclear Information System (INIS)

    Jeong, Hyunjo; Cho, Sungjong; Wei, Wei

    2011-01-01

    We present an analytical investigation for a baseline-free imaging of a defect in plate-like structures using the time-reversal of Lamb waves. We first consider the flexural wave (A 0 mode) propagation in a plate containing a defect, and reception and time reversal process of the output signal at the receiver. The received output signal is then composed of two parts: a directly propagated wave and a scattered wave from the defect. The time reversal of these waves recovers the original input signal, and produces two additional sidebands that contain the time-of-flight information on the defect location. One of the side-band signals is then extracted as a pure defect signal. A defect localization image is then constructed from a beamforming technique based on the time-frequency analysis of the side band signal for each transducer pair in a network of sensors. The simulation results show that the proposed scheme enables the accurate, baseline-free imaging of a defect. (fundamental areas of phenomenology(including applications))

  8. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    Science.gov (United States)

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. A long baseline global stereo matching based upon short baseline estimation

    Science.gov (United States)

    Li, Jing; Zhao, Hong; Li, Zigang; Gu, Feifei; Zhao, Zixin; Ma, Yueyang; Fang, Meiqi

    2018-05-01

    In global stereo vision, balancing the matching efficiency and computing accuracy seems to be impossible because they contradict each other. In the case of a long baseline, this contradiction becomes more prominent. In order to solve this difficult problem, this paper proposes a novel idea to improve both the efficiency and accuracy in global stereo matching for a long baseline. In this way, the reference images located between the long baseline image pairs are firstly chosen to form the new image pairs with short baselines. The relationship between the disparities of pixels in the image pairs with different baselines is revealed by considering the quantized error so that the disparity search range under the long baseline can be reduced by guidance of the short baseline to gain matching efficiency. Then, the novel idea is integrated into the graph cuts (GCs) to form a multi-step GC algorithm based on the short baseline estimation, by which the disparity map under the long baseline can be calculated iteratively on the basis of the previous matching. Furthermore, the image information from the pixels that are non-occluded under the short baseline but are occluded for the long baseline can be employed to improve the matching accuracy. Although the time complexity of the proposed method depends on the locations of the chosen reference images, it is usually much lower for a long baseline stereo matching than when using the traditional GC algorithm. Finally, the validity of the proposed method is examined by experiments based on benchmark datasets. The results show that the proposed method is superior to the traditional GC method in terms of efficiency and accuracy, and thus it is suitable for long baseline stereo matching.

  10. Variation in pre-treatment count lead time and its effect on baseline estimates of cage-level sea lice abundance.

    Science.gov (United States)

    Gautam, R; Boerlage, A S; Vanderstichel, R; Revie, C W; Hammell, K L

    2016-11-01

    Treatment efficacy studies typically use pre-treatment sea lice abundance as the baseline. However, the pre-treatment counting window often varies from the day of treatment to several days before treatment. We assessed the effect of lead time on baseline estimates, using historical data (2010-14) from a sea lice data management programme (Fish-iTrends). Data were aggregated at the cage level for three life stages: (i) chalimus, (ii) pre-adult and adult male and (iii) adult female. Sea lice counts were log-transformed, and mean counts by lead time relative to treatment day were computed and compared separately for each life stage, using linear mixed models. There were 1,658 observations (treatment events) from 56 sites in 5 Bay Management Areas. Our study showed that lead time had a significant effect on the estimated sea lice abundance, which was moderated by season. During the late summer and autumn periods, counting on the day of treatment gave significantly higher values than other days and would be a more appropriate baseline estimate, while during spring and early summer abundance estimates were comparable among counts within 5 days of treatment. A season-based lead time window may be most appropriate when estimating baseline sea lice levels. © 2016 John Wiley & Sons Ltd.

  11. Comparison of pulsar positions from timing and very long baseline astrometry

    Science.gov (United States)

    Wang, J. B.; Coles, W. A.; Hobbs, G.; Shannon, R. M.; Manchester, R. N.; Kerr, M.; Yuan, J. P.; Wang, N.; Bailes, M.; Bhat, N. D. R.; Dai, S.; Dempsey, J.; Keith, M. J.; Lasky, P. D.; Levin, Y.; Osłowski, S.; Ravi, V.; Reardon, D. J.; Rosado, P. A.; Russell, C. J.; Spiewak, R.; van Straten, W.; Toomey, L.; Wen, L.; You, X.-P.; Zhu, X.-J.

    2017-07-01

    Pulsar positions can be measured with high precision using both pulsar timing methods and very long baseline interferometry (VLBI). Pulsar timing positions are referenced to a solar-system ephemeris, whereas VLBI positions are referenced to distant quasars. Here, we compare pulsar positions from published VLBI measurements with those obtained from pulsar timing data from the Nanshan and Parkes radio telescopes in order to relate the two reference frames. We find that the timing positions differ significantly from the VLBI positions (and also differ between different ephemerides). A statistically significant change in the obliquity of the ecliptic of 2.16 ± 0.33 mas is found for the JPL ephemeris DE405, but no significant rotation is found in subsequent JPL ephemerides. The accuracy with which we can relate the two frames is limited by the current uncertainties in the VLBI reference source positions and in matching the pulsars to their reference source. Not only do the timing positions depend on the ephemeris used in computing them, but also different segments of the timing data lead to varying position estimates. These variations are mostly common to all ephemerides, but slight changes are seen at the 10 μas level between ephemerides.

  12. Evaluation of the fibromyalgia impact questionnaire at baseline as a predictor for time to pain improvement in two clinical trials of pregabalin.

    Science.gov (United States)

    Bushmakin, A G; Cappelleri, J C; Chandran, A B; Zlateva, G

    2013-01-01

    The Fibromyalgia Impact Questionnaire (FIQ) is a patient-reported outcome that evaluates the impact of fibromyalgia (FM) on daily life. This study evaluated the relationships between the functional status of FM patients, measured with the FIQ at baseline, and median time to a clinically relevant pain reduction. Data were derived from two randomised, placebo-controlled trials that evaluated pregabalin 300, 450 and 600 mg/day for the treatment of FM. The Kaplan-Meier (nonparametric) method was applied to estimate median times to 'transient' and 'stable' events. The transient event was defined as a ≥ 27.9% improvement on an 11-point daily pain diary scale (0 = no pain, 10 = worst possible pain), and the stable event was defined as the mean of the daily improvements ≥ 27.9% relative to baseline over the subsequent study duration starting on the day of the transient event. A parametric model using time-to-event analysis was developed for evaluating the relationship between baseline FIQ score and the median time to these events. Median time was longer among patients treated with placebo relative to pregabalin for the transient events (11-12 days vs. 5-7 days) and stable events (86 days vs. 13-29 days). A significant association was observed between baseline FIQ scores and median time to transient and stable events (p FIQ scores of 10, and 9.1-9.6 days for FIQ scores of 100; for stable pain reduction events, the median time ranged from 11.0 to 13.0 days and from 27.0 to 28.5 days for baseline FIQ scores of 10 and 100 respectively. Time to a clinically relevant reduction in pain was significantly associated with FM severity at baseline as measured by the FIQ. Such an analysis can inform patient and physician expectations in clinical practice. © 2012 Blackwell Publishing Ltd.

  13. Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

    International Nuclear Information System (INIS)

    Takao, Seishin; Miyamoto, Naoki; Matsuura, Taeko; Onimaru, Rikiya; Katoh, Norio; Inoue, Tetsuya; Sutherland, Kenneth Lee; Suzuki, Ryusuke; Shirato, Hiroki; Shimizu, Shinichi

    2016-01-01

    Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

  14. Integrated planning: A baseline development perspective

    International Nuclear Information System (INIS)

    Clauss, L.; Chang, D.

    1994-01-01

    The FEMP Baseline establishes the basis for integrating environmental activity technical requirements with their cost and schedule elements. The result is a path forward to successfully achieving the FERMCO mission. Specific to cost management, the FEMP Baseline has been incorporate into the FERMCO Project Control System (PCS) to provide a time-phased budget plan against which contractor performance is measured with an earned value management system. The result is the Performance Measurement Baseline (PMB), an important tool for keeping cost under control

  15. Hot flush frequency and severity at baseline as predictors of time to transient and stable treatment success: pooled analysis of two CE/BZA studies.

    Science.gov (United States)

    Pinkerton, JoAnn V; Bushmakin, Andrew G; Bobula, Joel; Lavenberg, Joanne; Komm, Barry S; Abraham, Lucy

    2017-12-01

    To evaluate the impact of baseline hot flush frequency and severity on time to symptom improvement during treatment with conjugated estrogens/bazedoxifene (CE/BZA). Data were pooled through week 12 from two randomized placebo-controlled trials (SMART-1 and SMART-2) of nonhysterectomized postmenopausal women with hot flushes treated with CE 0.45 mg/BZA 20 mg or CE 0.625 mg/BZA 20 mg. Time to transient and stable improvement (≥ 50% reduction in hot flush frequency/severity) was estimated using nonparametric models. Transient improvement in hot flush frequency occurred earlier in women treated with CE 0.45 mg/BZA 20 mg with less frequent versus more frequent baseline hot flushes per day: median time to transient improvement was 2, 7, and 11 days for women with hot flushes per day at baseline, respectively (P = 0.0009). Transient improvement in severity occurred earlier for women with less severe versus more severe baseline hot flushes: median time to transient improvement was 2, 6, and 16 days for women with mild, moderate, and severe hot flushes at baseline, respectively (P hot flushes take longer to achieve transient improvements with CE/BZA and should be encouraged to continue treatment, as it may take longer than a few weeks to achieve significant improvement.

  16. 40 CFR 74.20 - Data for baseline and alternative baseline.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Data for baseline and alternative baseline. 74.20 Section 74.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... baseline and alternative baseline. (a) Acceptable data. (1) The designated representative of a combustion...

  17. Reconstruction of baseline time-trace under changing environmental and operational conditions

    International Nuclear Information System (INIS)

    Aryan, P; Kotousov, A; Ng, C T; Wildy, S

    2016-01-01

    Compensation of changing environmental and operational conditions (EOC) is often necessary when using guided-wave based techniques for structural health monitoring in real-world applications. Many studies have demonstrated that the effect of changing EOC can mask damage to a degree that a critical defect might not be detected. Several effective strategies, specifically for compensating the temperature variations, have been developed in recent years. However, many other factors, such as changing humidity and boundary conditions or degradation of material properties, have not received much attention. This paper describes a practical method for reconstruction of the baseline time-trace corresponding to the current EOC. Thus, there is no need for differentiation or compensation procedures when using this method for damage diagnosis. It is based on 3D surface measurements of the velocity field near the actuator using laser vibrometry, in conjunction with high-fidelity finite element simulations of guided wave propagation in free from defects structure. To demonstrate the feasibility and efficiency of the proposed method we provide several examples of the reconstruction and damage detection. (paper)

  18. Reconstruction of baseline time-trace under changing environmental and operational conditions

    Science.gov (United States)

    Aryan, P.; Kotousov, A.; Ng, C. T.; Wildy, S.

    2016-03-01

    Compensation of changing environmental and operational conditions (EOC) is often necessary when using guided-wave based techniques for structural health monitoring in real-world applications. Many studies have demonstrated that the effect of changing EOC can mask damage to a degree that a critical defect might not be detected. Several effective strategies, specifically for compensating the temperature variations, have been developed in recent years. However, many other factors, such as changing humidity and boundary conditions or degradation of material properties, have not received much attention. This paper describes a practical method for reconstruction of the baseline time-trace corresponding to the current EOC. Thus, there is no need for differentiation or compensation procedures when using this method for damage diagnosis. It is based on 3D surface measurements of the velocity field near the actuator using laser vibrometry, in conjunction with high-fidelity finite element simulations of guided wave propagation in free from defects structure. To demonstrate the feasibility and efficiency of the proposed method we provide several examples of the reconstruction and damage detection.

  19. Instantaneous Real-Time Kinematic Decimeter-Level Positioning with BeiDou Triple-Frequency Signals over Medium Baselines.

    Science.gov (United States)

    He, Xiyang; Zhang, Xiaohong; Tang, Long; Liu, Wanke

    2015-12-22

    Many applications, such as marine navigation, land vehicles location, etc., require real time precise positioning under medium or long baseline conditions. In this contribution, we develop a model of real-time kinematic decimeter-level positioning with BeiDou Navigation Satellite System (BDS) triple-frequency signals over medium distances. The ambiguities of two extra-wide-lane (EWL) combinations are fixed first, and then a wide lane (WL) combination is reformed based on the two EWL combinations for positioning. Theoretical analysis and empirical analysis is given of the ambiguity fixing rate and the positioning accuracy of the presented method. The results indicate that the ambiguity fixing rate can be up to more than 98% when using BDS medium baseline observations, which is much higher than that of dual-frequency Hatch-Melbourne-Wübbena (HMW) method. As for positioning accuracy, decimeter level accuracy can be achieved with this method, which is comparable to that of carrier-smoothed code differential positioning method. Signal interruption simulation experiment indicates that the proposed method can realize fast high-precision positioning whereas the carrier-smoothed code differential positioning method needs several hundreds of seconds for obtaining high precision results. We can conclude that a relatively high accuracy and high fixing rate can be achieved for triple-frequency WL method with single-epoch observations, displaying significant advantage comparing to traditional carrier-smoothed code differential positioning method.

  20. Instantaneous Real-Time Kinematic Decimeter-Level Positioning with BeiDou Triple-Frequency Signals over Medium Baselines

    Directory of Open Access Journals (Sweden)

    Xiyang He

    2015-12-01

    Full Text Available Many applications, such as marine navigation, land vehicles location, etc., require real time precise positioning under medium or long baseline conditions. In this contribution, we develop a model of real-time kinematic decimeter-level positioning with BeiDou Navigation Satellite System (BDS triple-frequency signals over medium distances. The ambiguities of two extra-wide-lane (EWL combinations are fixed first, and then a wide lane (WL combination is reformed based on the two EWL combinations for positioning. Theoretical analysis and empirical analysis is given of the ambiguity fixing rate and the positioning accuracy of the presented method. The results indicate that the ambiguity fixing rate can be up to more than 98% when using BDS medium baseline observations, which is much higher than that of dual-frequency Hatch-Melbourne-Wübbena (HMW method. As for positioning accuracy, decimeter level accuracy can be achieved with this method, which is comparable to that of carrier-smoothed code differential positioning method. Signal interruption simulation experiment indicates that the proposed method can realize fast high-precision positioning whereas the carrier-smoothed code differential positioning method needs several hundreds of seconds for obtaining high precision results. We can conclude that a relatively high accuracy and high fixing rate can be achieved for triple-frequency WL method with single-epoch observations, displaying significant advantage comparing to traditional carrier-smoothed code differential positioning method.

  1. Baseline predictors of sputum culture conversion in pulmonary tuberculosis: importance of cavities, smoking, time to detection and W-Beijing genotype.

    Directory of Open Access Journals (Sweden)

    Marianne E Visser

    Full Text Available Time to detection (TTD on automated liquid mycobacterial cultures is an emerging biomarker of tuberculosis outcomes. The M. tuberculosis W-Beijing genotype is spreading globally, indicating a selective advantage. There is a paucity of data on the association between baseline TTD and W-Beijing genotype and tuberculosis outcomes.To assess baseline predictors of failure of sputum culture conversion, within the first 2 months of antitubercular therapy, in participants with pulmonary tuberculosis.Between May 2005 and August 2008 we conducted a prospective cohort study of time to sputum culture conversion in ambulatory participants with first episodes of smear and culture positive pulmonary tuberculosis attending two primary care clinics in Cape Town, South Africa. Rifampicin resistance (diagnosed on phenotypic susceptibility testing was an exclusion criterion. Sputum was collected weekly for 8 weeks for mycobacterial culture on liquid media (BACTEC MGIT 960. Due to missing data, multiple imputation was performed. Time to sputum culture conversion was analysed using a Cox-proportional hazards model. Bayesian model averaging determined the posterior effect probability for each variable.113 participants were enrolled (30.1% female, 10.5% HIV-infected, 44.2% W-Beijing genotype, and 89% cavities. On Kaplan Meier analysis 50.4% of participants underwent sputum culture conversion by 8 weeks. The following baseline factors were associated with slower sputum culture conversion: TTD (adjusted hazard ratio (aHR = 1.11, 95% CI 1.02; 1.2, lung cavities (aHR = 0.13, 95% CI 0.02; 0.95, ever smoking (aHR = 0.32, 95% CI 0.1; 1.02 and the W-Beijing genotype (aHR = 0.51, 95% CI 0.25; 1.07. On Bayesian model averaging, posterior probability effects were strong for TTD, lung cavitation and smoking and moderate for W-Beijing genotype.We found that baseline TTD, smoking, cavities and W-Beijing genotype were associated with delayed 2 month sputum culture

  2. Baseline predictors of sputum culture conversion in pulmonary tuberculosis: importance of cavities, smoking, time to detection and W-Beijing genotype.

    Science.gov (United States)

    Visser, Marianne E; Stead, Michael C; Walzl, Gerhard; Warren, Rob; Schomaker, Michael; Grewal, Harleen M S; Swart, Elizabeth C; Maartens, Gary

    2012-01-01

    Time to detection (TTD) on automated liquid mycobacterial cultures is an emerging biomarker of tuberculosis outcomes. The M. tuberculosis W-Beijing genotype is spreading globally, indicating a selective advantage. There is a paucity of data on the association between baseline TTD and W-Beijing genotype and tuberculosis outcomes. To assess baseline predictors of failure of sputum culture conversion, within the first 2 months of antitubercular therapy, in participants with pulmonary tuberculosis. Between May 2005 and August 2008 we conducted a prospective cohort study of time to sputum culture conversion in ambulatory participants with first episodes of smear and culture positive pulmonary tuberculosis attending two primary care clinics in Cape Town, South Africa. Rifampicin resistance (diagnosed on phenotypic susceptibility testing) was an exclusion criterion. Sputum was collected weekly for 8 weeks for mycobacterial culture on liquid media (BACTEC MGIT 960). Due to missing data, multiple imputation was performed. Time to sputum culture conversion was analysed using a Cox-proportional hazards model. Bayesian model averaging determined the posterior effect probability for each variable. 113 participants were enrolled (30.1% female, 10.5% HIV-infected, 44.2% W-Beijing genotype, and 89% cavities). On Kaplan Meier analysis 50.4% of participants underwent sputum culture conversion by 8 weeks. The following baseline factors were associated with slower sputum culture conversion: TTD (adjusted hazard ratio (aHR) = 1.11, 95% CI 1.02; 1.2), lung cavities (aHR = 0.13, 95% CI 0.02; 0.95), ever smoking (aHR = 0.32, 95% CI 0.1; 1.02) and the W-Beijing genotype (aHR = 0.51, 95% CI 0.25; 1.07). On Bayesian model averaging, posterior probability effects were strong for TTD, lung cavitation and smoking and moderate for W-Beijing genotype. We found that baseline TTD, smoking, cavities and W-Beijing genotype were associated with delayed 2 month sputum culture. Larger

  3. THE US LONG BASELINE NEUTRINO EXPERIMENT STUDY.

    Energy Technology Data Exchange (ETDEWEB)

    BISHAI,M.

    2007-08-06

    The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory (BNL)and Fermi National Accelerator Laboratory (FNAL) to investigate the potential for future U.S. based long baseline neutrino oscillation experiments using MW class conventional neutrino beams that can be produced at FNAL. The experimental baselines are based on two possible detector locations: (1) off-axis to the existing FNAL NuMI beamline at baselines of 700 to 810 km and (2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from FNAL aimed at a massive detector with a baseline of > 1000km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2{sup o}.

  4. Developing RESRAD-BASELINE for environmental baseline risk assessment

    International Nuclear Information System (INIS)

    Cheng, Jing-Jy.

    1995-01-01

    RESRAD-BASELINE is a computer code developed at Argonne developed at Argonne National Laboratory for the US Department of Energy (DOE) to perform both radiological and chemical risk assessments. The code implements the baseline risk assessment guidance of the US Environmental Protection Agency (EPA 1989). The computer code calculates (1) radiation doses and cancer risks from exposure to radioactive materials, and (2) hazard indexes and cancer risks from exposure to noncarcinogenic and carcinogenic chemicals, respectively. The user can enter measured or predicted environmental media concentrations from the graphic interface and can simulate different exposure scenarios by selecting the appropriate pathways and modifying the exposure parameters. The database used by PESRAD-BASELINE includes dose conversion factors and slope factors for radionuclides and toxicity information and properties for chemicals. The user can modify the database for use in the calculation. Sensitivity analysis can be performed while running the computer code to examine the influence of the input parameters. Use of RESRAD-BASELINE for risk analysis is easy, fast, and cost-saving. Furthermore, it ensures in consistency in methodology for both radiological and chemical risk analyses

  5. Baseline budgeting for continuous improvement.

    Science.gov (United States)

    Kilty, G L

    1999-05-01

    This article is designed to introduce the techniques used to convert traditionally maintained department budgets to baseline budgets. This entails identifying key activities, evaluating for value-added, and implementing continuous improvement opportunities. Baseline Budgeting for Continuous Improvement was created as a result of a newly named company president's request to implement zero-based budgeting. The president was frustrated with the mind-set of the organization, namely, "Next year's budget should be 10 to 15 percent more than this year's spending." Zero-based budgeting was not the answer, but combining the principles of activity-based costing and the Just-in-Time philosophy of eliminating waste and continuous improvement did provide a solution to the problem.

  6. MALDI-TOF Baseline Drift Removal Using Stochastic Bernstein Approximation

    Directory of Open Access Journals (Sweden)

    Howard Daniel

    2006-01-01

    Full Text Available Stochastic Bernstein (SB approximation can tackle the problem of baseline drift correction of instrumentation data. This is demonstrated for spectral data: matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF data. Two SB schemes for removing the baseline drift are presented: iterative and direct. Following an explanation of the origin of the MALDI-TOF baseline drift that sheds light on the inherent difficulty of its removal by chemical means, SB baseline drift removal is illustrated for both proteomics and genomics MALDI-TOF data sets. SB is an elegant signal processing method to obtain a numerically straightforward baseline shift removal method as it includes a free parameter that can be optimized for different baseline drift removal applications. Therefore, research that determines putative biomarkers from the spectral data might benefit from a sensitivity analysis to the underlying spectral measurement that is made possible by varying the SB free parameter. This can be manually tuned (for constant or tuned with evolutionary computation (for .

  7. Dynamic baseline detection method for power data network service

    Science.gov (United States)

    Chen, Wei

    2017-08-01

    This paper proposes a dynamic baseline Traffic detection Method which is based on the historical traffic data for the Power data network. The method uses Cisco's NetFlow acquisition tool to collect the original historical traffic data from network element at fixed intervals. This method uses three dimensions information including the communication port, time, traffic (number of bytes or number of packets) t. By filtering, removing the deviation value, calculating the dynamic baseline value, comparing the actual value with the baseline value, the method can detect whether the current network traffic is abnormal.

  8. High Baseline Postconcussion Symptom Scores and Concussion Outcomes in Athletes.

    Science.gov (United States)

    Custer, Aimee; Sufrinko, Alicia; Elbin, R J; Covassin, Tracey; Collins, Micky; Kontos, Anthony

    2016-02-01

    Some healthy athletes report high levels of baseline concussion symptoms, which may be attributable to several factors (eg, illness, personality, somaticizing). However, the role of baseline symptoms in outcomes after sport-related concussion (SRC) has not been empirically examined. To determine if athletes with high symptom scores at baseline performed worse than athletes without baseline symptoms on neurocognitive testing after SRC. Cohort study. High school and collegiate athletic programs. A total of 670 high school and collegiate athletes participated in the study. Participants were divided into groups with either no baseline symptoms (Postconcussion Symptom Scale [PCSS] score = 0, n = 247) or a high level of baseline symptoms (PCSS score > 18 [top 10% of sample], n = 68). Participants were evaluated at baseline and 2 to 7 days after SRC with the Immediate Post-concussion Assessment and Cognitive Test and PCSS. Outcome measures were Immediate Post-concussion Assessment and Cognitive Test composite scores (verbal memory, visual memory, visual motor processing speed, and reaction time) and total symptom score on the PCSS. The groups were compared using repeated-measures analyses of variance with Bonferroni correction to assess interactions between group and time for symptoms and neurocognitive impairment. The no-symptoms group represented 38% of the original sample, whereas the high-symptoms group represented 11% of the sample. The high-symptoms group experienced a larger decline from preinjury to postinjury than the no-symptoms group in verbal (P = .03) and visual memory (P = .05). However, total concussion-symptom scores increased from preinjury to postinjury for the no-symptoms group (P = .001) but remained stable for the high-symptoms group. Reported baseline symptoms may help identify athletes at risk for worse outcomes after SRC. Clinicians should examine baseline symptom levels to better identify patients for earlier referral and treatment for their

  9. Extracting Baseline Electricity Usage Using Gradient Tree Boosting

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Taehoon [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Lee, Dongeun [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Choi, Jaesik [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Spurlock, Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sim, Alex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wu, Kesheng [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-05

    To understand how specific interventions affect a process observed over time, we need to control for the other factors that influence outcomes. Such a model that captures all factors other than the one of interest is generally known as a baseline. In our study of how different pricing schemes affect residential electricity consumption, the baseline would need to capture the impact of outdoor temperature along with many other factors. In this work, we examine a number of different data mining techniques and demonstrate Gradient Tree Boosting (GTB) to be an effective method to build the baseline. We train GTB on data prior to the introduction of new pricing schemes, and apply the known temperature following the introduction of new pricing schemes to predict electricity usage with the expected temperature correction. Our experiments and analyses show that the baseline models generated by GTB capture the core characteristics over the two years with the new pricing schemes. In contrast to the majority of regression based techniques which fail to capture the lag between the peak of daily temperature and the peak of electricity usage, the GTB generated baselines are able to correctly capture the delay between the temperature peak and the electricity peak. Furthermore, subtracting this temperature-adjusted baseline from the observed electricity usage, we find that the resulting values are more amenable to interpretation, which demonstrates that the temperature-adjusted baseline is indeed effective.

  10. Baseline restoration technique based on symmetrical zero-area trapezoidal pulse shaper

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Guoqiang, E-mail: 24829500@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Yang, Jian, E-mail: 22105653@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Hu, Tianyu; Ge, Liangquan [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Ouyang, Xiaoping [Northwest Institute of Nuclear Technology, Xi’an 710024,China (China); Zhang, Qingxian; Gu, Yi [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China)

    2017-06-21

    Since the baseline of the unipolar pulse shaper have the direct-current (DC) offset and drift, an additional baseline estimator is need to obtain baseline values in real-time. The bipolar zero-area (BZA) pulse shapers can be used for baseline restoration, but they cannot restrain the baseline drift due to their asymmetrical shape. In this study, three trapezoids are synthesized as a symmetrical zero-area (SZA) shape, which can remove the DC offset and restrain the baseline drift. This baseline restoration technique can be easily implemented in digital pulse processing (DPP) systems base on the recursive algorithm. To strengthen our approach, the iron's characteristic x-ray was detected using a Si-PIN diode detector. Compared with traditional trapezoidal pulse shapers, the SZA trapezoidal pulse shaper improved the energy resolution from 237 eV to 216 eV for the 6.403 keV Kα peak.

  11. On the feasibility of routine baseline improvement in processing of geomagnetic observatory data

    Science.gov (United States)

    Soloviev, Anatoly; Lesur, Vincent; Kudin, Dmitry

    2018-02-01

    We propose a new approach to the calculation of regular baselines at magnetic observatories. The proposed approach is based on the simultaneous analysis of the irregular absolute observations and the continuous time-series deltaF, widely used for estimating the data quality. The systematic deltaF analysis allows to take into account all available information about the operation of observatory instruments (i.e., continuous records of the field variations and its modulus) in the intervals between the times of absolute observations, as compared to the traditional baseline calculation where only spot values are considered. To establish a connection with the observed spot baseline values, we introduce a function for approximate evaluation of the intermediate baseline values. An important feature of the algorithm is its quantitative estimation of the resulting data precision and thus determination of the problematic fragments in raw data. We analyze the robustness of the algorithm operation using synthetic data sets. We also compare baselines and definitive data derived by the proposed algorithm with those derived by the traditional approach using Saint Petersburg observatory data, recorded in 2015 and accepted by INTERMAGNET. It is shown that the proposed method allows to essentially improve the resulting data quality when baseline data are not good enough. The obtained results prove that the baseline variability in time might be quite rapid.[Figure not available: see fulltext.

  12. Safe and sensible preprocessing and baseline correction of pupil-size data.

    Science.gov (United States)

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-02-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

  13. Addendum to the 2015 Eastern Interconnect Baselining and Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Follum, James D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    This report serves as an addendum to the report 2015 Eastern Interconnect Baselining and Analysis Report (Amidan, Follum, and Freeman, 2015). This addendum report investigates the following: the impact of shorter record lengths and of adding a daily regularization term to the date/time models for angle pair measurements, additional development of a method to monitor the trend in phase angle pairs, the effect of changing the length of time to determine a baseline, when calculating atypical events, and a comparison between quantitatively discovered atypical events and actual events.

  14. Baselining PMU Data to Find Patterns and Anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G.; Follum, James D.; Freeman, Kimberly A.; Dagle, Jeffery E.

    2016-10-25

    This paper looks at the application of situational awareness methodologies with respect to power grid data. These methodologies establish baselines that look for typical patterns and atypical behavior in the data. The objectives of the baselining analyses are to provide: real-time analytics, the capability to look at historical trends and events, and reliable predictions of the near future state of the grid. Multivariate algorithms were created to establish normal baseline behavior and then score each moment in time according to its variance from the baseline. Detailed multivariate analytical techniques are described in this paper that produced ways to identify typical patterns and atypical behavior. In this case, atypical behavior is behavior that is unenvisioned. Visualizations were also produced to help explain the behavior that was identified mathematically. Examples are shown to help describe how to read and interpret the analyses and visualizations. Preliminary work has been performed on PMU data sets from BPA (Bonneville Power Administration) and EI (Eastern Interconnect). Actual results are not fully shown here because of confidentiality issues. Comparisons between atypical events found mathematically and actual events showed that many of the actual events are also atypical events; however there are many atypical events that do not correlate to any actual events. Additional work needs to be done to help classify the atypical events into actual events, so that the importance of the events can be better understood.

  15. Measurement of baseline and orientation between distributed aerospace platforms.

    Science.gov (United States)

    Wang, Wen-Qin

    2013-01-01

    Distributed platforms play an important role in aerospace remote sensing, radar navigation, and wireless communication applications. However, besides the requirement of high accurate time and frequency synchronization for coherent signal processing, the baseline between the transmitting platform and receiving platform and the orientation of platform towards each other during data recording must be measured in real time. In this paper, we propose an improved pulsed duplex microwave ranging approach, which allows determining the spatial baseline and orientation between distributed aerospace platforms by the proposed high-precision time-interval estimation method. This approach is novel in the sense that it cancels the effect of oscillator frequency synchronization errors due to separate oscillators that are used in the platforms. Several performance specifications are also discussed. The effectiveness of the approach is verified by simulation results.

  16. Desflurane Allows for a Faster Emergence when Compared to Sevoflurane Without Affecting the Baseline Cognitive Recovery Time.

    Directory of Open Access Journals (Sweden)

    Joseph G. Werner

    2015-10-01

    Full Text Available Aims, We compared the effect of desflurane and sevoflurane on anesthesia recovery time in patients undergoing urological cystoscopic surgery. The Short Orientation Memory Concentration Test (SOMCT measured and compared cognitive impairment between groups and coughing was assessed throughout the anesthetic.Methods and Materials, This investigation included 75 ambulatory patients. Patients were randomized to receive either desflurane or sevoflurane. Inhalational anesthetics were discontinued after removal of the cystoscope and once repositioning of the patient was final. Coughing assessment and awakening time from anesthesia were assessed by a blinded observer.Statistical analysis used: Statistical analysis was performed by using t-test for parametric variables and Mann-Whitney U test for nonparametric variables. Results, The primary endpoint, mean time to eye-opening, was 5.0±2.5 minutes for desflurane, and 7.9±4.1 minutes for sevoflurane (p <0.001. There were no significant differences in time to SOMCT recovery (p=0.109, overall time spent in the post anesthesia care unit (p=0.924 or time to discharge (p=0.363. Median time until readiness for discharge was nine minutes in the desflurane group, while the sevoflurane group had a median time of 20 minutes (p=0.020. The overall incidence of coughing during the perioperative period was significantly higher in the desflurane (p=0.030. Conclusions, We re-confirmed that patients receiving desflurane had a faster emergence and met the criteria to be discharged from the post anesthesia care unit earlier. No difference was found in time to return to baseline cognition between desflurane and sevoflurane.

  17. STATUS OF THE US LONG BASELINE NEUTRINO EXPERIMENT STUDY.

    Energy Technology Data Exchange (ETDEWEB)

    BISHAI,M.

    2006-09-21

    The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory and Fermi National Accelerator Laboratory to investigate the potential for future U.S. based long baseline neutrino oscillation experiments beyond the currently planned program. The Study focused on MW class convention at neutrino beams that can be produced at Fermilab or BNL. The experimental baselines are based on two possible detector locations: (1) off-axis to the existing Fermilab NuMI beamline at baselines of 700 to 810 km and (2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000 km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from Fermilab or BNL aimed at a massive detector with a baseline of > 1000 km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2.2{sup o}.

  18. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  19. Deep sequencing analysis of HIV-1 reverse transcriptase at baseline and time of failure in patients receiving rilpivirine in the phase III studies ECHO and THRIVE.

    Science.gov (United States)

    Van Eygen, Veerle; Thys, Kim; Van Hove, Carl; Rimsky, Laurence T; De Meyer, Sandra; Aerssens, Jeroen; Picchio, Gaston; Vingerhoets, Johan

    2016-05-01

    Minority variants (1.0-25.0%) were evaluated by deep sequencing (DS) at baseline and virological failure (VF) in a selection of antiretroviral treatment-naïve, HIV-1-infected patients from the rilpivirine ECHO/THRIVE phase III studies. Linkage between frequently emerging resistance-associated mutations (RAMs) was determined. DS (llIumina®) and population sequencing (PS) results were available at baseline for 47 VFs and time of failure for 48 VFs; and at baseline for 49 responders matched for baseline characteristics. Minority mutations were accurately detected at frequencies down to 1.2% of the HIV-1 quasispecies. No baseline minority rilpivirine RAMs were detected in VFs; one responder carried 1.9% F227C. Baseline minority mutations associated with resistance to other non-nucleoside reverse transcriptase inhibitors (NNRTIs) were detected in 8/47 VFs (17.0%) and 7/49 responders (14.3%). Baseline minority nucleoside/nucleotide reverse transcriptase inhibitor (NRTI) RAMs M184V and L210W were each detected in one VF (none in responders). At failure, two patients without NNRTI RAMs by PS carried minority rilpivirine RAMs K101E and/or E138K; and five additional patients carried other minority NNRTI RAMs V90I, V106I, V179I, V189I, and Y188H. Overall at failure, minority NNRTI RAMs and NRTI RAMs were found in 29/48 (60.4%) and 16/48 VFs (33.3%), respectively. Linkage analysis showed that E138K and K101E were usually not observed on the same viral genome. In conclusion, baseline minority rilpivirine RAMs and other NNRTI/NRTI RAMs were uncommon in the rilpivirine arm of the ECHO and THRIVE studies. DS at failure showed emerging NNRTI resistant minority variants in seven rilpivirine VFs who had no detectable NNRTI RAMs by PS. © 2015 Wiley Periodicals, Inc.

  20. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    Science.gov (United States)

    Beaton, K. H.; Bloomberg, J. J.

    2016-01-01

    One of the greatest challenges for sensorimotor adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. This information could guide individually customized countermeasures, which would enable more efficient use of crew time and provide better outcomes. The principal aim of this work is to look for baseline performance metrics that relate to locomotor adaptability. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations ("noise") in motor performance, as a predictor of individual adaptive capabilities.

  1. Program reference schedule baseline

    International Nuclear Information System (INIS)

    1986-07-01

    This Program Reference Schedule Baseline (PRSB) provides the baseline Program-level milestones and associated schedules for the Civilian Radioactive Waste Management Program. It integrates all Program-level schedule-related activities. This schedule baseline will be used by the Director, Office of Civilian Radioactive Waste Management (OCRWM), and his staff to monitor compliance with Program objectives. Chapter 1 includes brief discussions concerning the relationship of the PRSB to the Program Reference Cost Baseline (PRCB), the Mission Plan, the Project Decision Schedule, the Total System Life Cycle Cost report, the Program Management Information System report, the Program Milestone Review, annual budget preparation, and system element plans. Chapter 2 includes the identification of all Level 0, or Program-level, milestones, while Chapter 3 presents and discusses the critical path schedules that correspond to those Level 0 milestones

  2. Time-aggregation effects on the baseline of continuous-time and discrete-time hazard models

    NARCIS (Netherlands)

    ter Hofstede, F.; Wedel, M.

    In this study we reinvestigate the effect of time-aggregation for discrete- and continuous-time hazard models. We reanalyze the results of a previous Monte Carlo study by ter Hofstede and Wedel (1998), in which the effects of time-aggregation on the parameter estimates of hazard models were

  3. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    Science.gov (United States)

    Beaton, K. H.; Bloomberg, J. J.

    2014-01-01

    One of the greatest challenges surrounding adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. Such knowledge could guide individually customized countermeasures, which would enable more efficient use of crew time, both preflight and inflight, and provide better outcomes. The primary goal of this project is to look for a baseline performance metric that can forecast sensorimotor adaptability without exposure to an adaptive stimulus. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations in motor performance, as a predictor of individual sensorimotor adaptive capabilities. To-date, a strong relationship has been found between baseline inter-trial correlations and adaptability in two oculomotor systems. For this project, we will explore an analogous predictive mechanism in the locomotion system. METHODS: Baseline Inter-trial Correlations: Inter-trial correlations specify the relationships among repeated trials of a given task that transpire as a consequence of correcting for previous performance errors over multiple timescales. We can quantify the strength of inter-trial correlations by measuring the decay of the autocorrelation function (ACF), which describes how rapidly information from past trials is "forgotten." Processes whose ACFs decay more slowly exhibit longer-term inter-trial correlations (longer memory processes), while processes whose ACFs decay more rapidly exhibit shorterterm inter-trial correlations (shorter memory processes). Longer-term correlations reflect low-frequency activity, which is more easily

  4. CryoSat SAR/SARin Level1b products: assessment of BaselineC and improvements towards BaselineD

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Bouffard, Jerome; Parrinello, Tommaso

    2017-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvements in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. The current IPF, Baseline C, was released in operation in April 2015 and the second CryoSat reprocessing campaign was jointly initiated, taking benefit of the upgrade implemented in the IPF1 processing chain but also of some specific configurations for the calibration corrections. In particular, the CryoSat Level1b BaselineC products generated in the framework of the second reprocessing campaign include refined information for what concerns the mispointing angles and the calibration corrections. This poster will thus detail thus the evolutions that are currently planned for the CryoSat BaselineD SAR/SARin Level1b products and the corresponding quality improvements that are expected.

  5. The relationship between psychological distress and baseline sports-related concussion testing.

    Science.gov (United States)

    Bailey, Christopher M; Samples, Hillary L; Broshek, Donna K; Freeman, Jason R; Barth, Jeffrey T

    2010-07-01

    This study examined the effect of psychological distress on neurocognitive performance measured during baseline concussion testing. Archival data were utilized to examine correlations between personality testing and computerized baseline concussion testing. Significantly correlated personality measures were entered into linear regression analyses, predicting baseline concussion testing performance. Suicidal ideation was examined categorically. Athletes underwent testing and screening at a university athletic training facility. Participants included 47 collegiate football players 17 to 19 years old, the majority of whom were in their first year of college. Participants were administered the Concussion Resolution Index (CRI), an internet-based neurocognitive test designed to monitor and manage both at-risk and concussed athletes. Participants took the Personality Assessment Inventory (PAI), a self-administered inventory designed to measure clinical syndromes, treatment considerations, and interpersonal style. Scales and subscales from the PAI were utilized to determine the influence psychological distress had on the CRI indices: simple reaction time, complex reaction time, and processing speed. Analyses revealed several significant correlations among aspects of somatic concern, depression, anxiety, substance abuse, and suicidal ideation and CRI performance, each with at least a moderate effect. When entered into a linear regression, the block of combined psychological symptoms accounted for a significant amount of baseline CRI performance, with moderate to large effects (r = 0.23-0.30). When examined categorically, participants with suicidal ideation showed significantly slower simple reaction time and complex reaction time, with a similar trend on processing speed. Given the possibility of obscured concussion deficits after injury, implications for premature return to play, and the need to target psychological distress outright, these findings heighten the clinical

  6. Placental baseline conditions modulate the hyperoxic BOLD-MRI response.

    Science.gov (United States)

    Sinding, Marianne; Peters, David A; Poulsen, Sofie S; Frøkjær, Jens B; Christiansen, Ole B; Petersen, Astrid; Uldbjerg, Niels; Sørensen, Anne

    2018-01-01

    Human pregnancies complicated by placental dysfunction may be characterized by a high hyperoxic Blood oxygen level-dependent (BOLD) MRI response. The pathophysiology behind this phenomenon remains to be established. The aim of this study was to evaluate whether it is associated with altered placental baseline conditions, including a lower oxygenation and altered tissue morphology, as estimated by the placental transverse relaxation time (T2*). We included 49 normal pregnancies (controls) and 13 pregnancies complicated by placental dysfunction (cases), defined by a birth weight baseline BOLD)/baseline BOLD) from a dynamic single-echo gradient-recalled echo (GRE) MRI sequence and the absolute ΔT2* (hyperoxic T2*- baseline T2*) from breath-hold multi-echo GRE sequences. In the control group, the relative ΔBOLD response increased during gestation from 5% in gestational week 20 to 20% in week 40. In the case group, the relative ΔBOLD response was significantly higher (mean Z-score 4.94; 95% CI 2.41, 7.47). The absolute ΔT2*, however, did not differ between controls and cases (p = 0.37), whereas the baseline T2* was lower among cases (mean Z-score -3.13; 95% CI -3.94, -2.32). Furthermore, we demonstrated a strong negative linear correlation between the Log 10 ΔBOLD response and the baseline T2* (r = -0.88, p baseline conditions, as the absolute increase in placental oxygenation (ΔT2*) does not differ between groups. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Spent nuclear fuel technical baseline description, Fiscal Year 1996: Volume II, supporting data

    International Nuclear Information System (INIS)

    Womack, J.C.

    1995-11-01

    The Technical Baseline Description documents the Project-Level functions and requirements, along with associated enabling assumptions, issues, trade studies, interfaces, and products. It is a snapshot in time of the baseline at the beginning of September 1995. It supports the individual subprojects in the development of lower-tier functions, requirements, and specifications in FY 1996. It also supports the need for Hanford site planning to be based on an integrated Hanford site systems engineering technical baseline; and is traceable to that baseline. This document replaces and supercedes WHC-SD-SNF-SD-003

  8. DairyBISS Baseline report

    NARCIS (Netherlands)

    Buizer, N.N.; Berhanu, Tinsae; Murutse, Girmay; Vugt, van S.M.

    2015-01-01

    This baseline report of the Dairy Business Information Service and Support (DairyBISS) project presents the findings of a baseline survey among 103 commercial farms and 31 firms and advisors working in the dairy value chain. Additional results from the survey among commercial dairy farms are

  9. Baseline rationing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    The standard problem of adjudicating conflicting claims describes a situation in which a given amount of a divisible good has to be allocated among agents who hold claims against it exceeding the available amount. This paper considers more general rationing problems in which, in addition to claims...... to international protocols for the reduction of greenhouse emissions, or water distribution in drought periods. We define a family of allocation methods for such general rationing problems - called baseline rationing rules - and provide an axiomatic characterization for it. Any baseline rationing rule within...... the family is associated with a standard rule and we show that if the latter obeys some properties reflecting principles of impartiality, priority and solidarity, the former obeys them too....

  10. A novel type of very long baseline astronomical intensity interferometer

    Science.gov (United States)

    Borra, Ermanno F.

    2013-12-01

    This article presents a novel type of very long baseline astronomical interferometer that uses the fluctuations, as a function of time, of the intensity measured by a quadratic detector, which is a common type of astronomical detector. The theory on which the technique is based is validated by laboratory experiments. Its outstanding principal advantages comes from the fact that the angular structure of an astronomical object is simply determined from the visibility of the minima of the spectrum of the intensity fluctuations measured by the detector, as a function of the frequency of the fluctuations, while keeping the spacing between mirrors constant. This would allow a simple setup capable of high angular resolutions because it could use an extremely large baseline. Another major interest is that it allows for a more efficient use of telescope time because observations at a single baseline are sufficient, while amplitude and intensity interferometers need several observations at different baselines. The fact that one does not have to move the telescopes would also allow detecting faster time variations because having to move the telescopes sets a lower limit to the time variations that can be detected. The technique uses wave interaction effects and thus has some characteristics in common with intensity interferometry. A disadvantage of the technique, like in intensity interferometry, is that it needs strong sources if observing at high frequencies (e.g. the visible). This is a minor disadvantage in the radio region. At high frequencies, this disadvantage is mitigated by the fact that, like in intensity interferometry, the requirements of the optical quality of the mirrors used are far less severe than in amplitude interferometry so that poor quality large reflectors (e.g. Cherenkov telescopes) can be used in the optical region.

  11. Baseline restoration using current conveyors

    International Nuclear Information System (INIS)

    Morgado, A.M.L.S.; Simoes, J.B.; Correia, C.M.

    1996-01-01

    A good performance of high resolution nuclear spectrometry systems, at high pulse rates, demands restoration of baseline between pulses, in order to remove rate dependent baseline shifts. This restoration is performed by circuits named baseline restorers (BLRs) which also remove low frequency noise, such as power supply hum and detector microphonics. This paper presents simple circuits for baseline restoration based on a commercial current conveyor (CCII01). Tests were performed, on two circuits, with periodic trapezoidal shaped pulses in order to measure the baseline restoration for several pulse rates and restorer duty cycles. For the current conveyor based Robinson restorer, the peak shift was less than 10 mV, for duty cycles up to 60%, at high pulse rates. Duty cycles up to 80% were also tested, being the maximum peak shift 21 mV. The peak shift for the current conveyor based Grubic restorer was also measured. The maximum value found was 30 mV at 82% duty cycle. Keeping the duty cycle below 60% improves greatly the restorer performance. The ability of both baseline restorer architectures to reject low frequency modulation is also measured, with good results on both circuits

  12. Baseline Q waves as a prognostic modulator in patients with ST-segment elevation: insights from the PLATO trial.

    Science.gov (United States)

    Siha, Hany; Das, Debraj; Fu, Yuling; Zheng, Yinggan; Westerhout, Cynthia M; Storey, Robert F; James, Stefan; Wallentin, Lars; Armstrong, Paul W

    2012-07-10

    Baseline Q waves may provide additional value compared with time from the onset of symptoms in predicting outcomes for patients with ST-segment elevation. We evaluated whether baseline Q waves superseded time from symptom onset as a prognostic marker of one-year mortality in patients with ST-segment elevation acute coronary syndrome. Our study was derived from data from patients undergoing primary percutaneous coronary intervention within 24 hours in the PLATelet inhibition and patient Outcomes trial Q waves on the baseline electrocardiogram were evaluated by a blinded core laboratory. We assessed the associations between baseline Q waves and time from symptom onset to percutaneous coronary intervention with peak biomarkers, ST-segment resolution on the discharge electrocardiogram, and one-year all-cause and vascular mortality. Of 4341 patients with ST-segment elevation, 46% had baseline Q waves. Compared to those without Q waves, those with baseline Q waves were older, more frequently male, had higher heart rates, more advanced Killip class and had a longer time between the onset of symptoms and percutaneous coronary intervention. They also had higher one-year all-cause mortality than patients without baseline Q waves (baseline Q waves: 4.9%; no baseline Q waves: 2.8%; hazard ratio [HR] 1.78, 95% confidence interval [CI] 1.29-2.45, p waves. After multivariable adjustment, baseline Q waves, but not time from symptom onset, were associated with a significant increase in all-cause mortality (adjusted HR 1.42, 95% CI 1.10-2.01, p = 0.046) and vascular mortality (adjusted HR 1.58, 95% CI 1.09-2.28, p = 0.02). The presence of baseline Q waves provides useful additional prognostic insight into the clinical outcome of patients with ST-segment elevation. Clinical Trials.gov registration no. NCT00391872.

  13. Large short-baseline νμ disappearance

    International Nuclear Information System (INIS)

    Giunti, Carlo; Laveder, Marco

    2011-01-01

    We analyze the LSND, KARMEN, and MiniBooNE data on short-baseline ν μ →ν e oscillations and the data on short-baseline ν e disappearance obtained in the Bugey-3 and CHOOZ reactor experiments in the framework of 3+1 antineutrino mixing, taking into account the MINOS observation of long-baseline ν μ disappearance and the KamLAND observation of very-long-baseline ν e disappearance. We show that the fit of the data implies that the short-baseline disappearance of ν μ is relatively large. We obtain a prediction of an effective amplitude sin 2 2θ μμ > or approx. 0.1 for short-baseline ν μ disappearance generated by 0.2 2 2 , which could be measured in future experiments.

  14. Informed baseline subtraction of proteomic mass spectrometry data aided by a novel sliding window algorithm.

    Science.gov (United States)

    Stanford, Tyman E; Bagley, Christopher J; Solomon, Patty J

    2016-01-01

    Proteomic matrix-assisted laser desorption/ionisation (MALDI) linear time-of-flight (TOF) mass spectrometry (MS) may be used to produce protein profiles from biological samples with the aim of discovering biomarkers for disease. However, the raw protein profiles suffer from several sources of bias or systematic variation which need to be removed via pre-processing before meaningful downstream analysis of the data can be undertaken. Baseline subtraction, an early pre-processing step that removes the non-peptide signal from the spectra, is complicated by the following: (i) each spectrum has, on average, wider peaks for peptides with higher mass-to-charge ratios ( m / z ), and (ii) the time-consuming and error-prone trial-and-error process for optimising the baseline subtraction input arguments. With reference to the aforementioned complications, we present an automated pipeline that includes (i) a novel 'continuous' line segment algorithm that efficiently operates over data with a transformed m / z -axis to remove the relationship between peptide mass and peak width, and (ii) an input-free algorithm to estimate peak widths on the transformed m / z scale. The automated baseline subtraction method was deployed on six publicly available proteomic MS datasets using six different m/z-axis transformations. Optimality of the automated baseline subtraction pipeline was assessed quantitatively using the mean absolute scaled error (MASE) when compared to a gold-standard baseline subtracted signal. Several of the transformations investigated were able to reduce, if not entirely remove, the peak width and peak location relationship resulting in near-optimal baseline subtraction using the automated pipeline. The proposed novel 'continuous' line segment algorithm is shown to far outperform naive sliding window algorithms with regard to the computational time required. The improvement in computational time was at least four-fold on real MALDI TOF-MS data and at least an order of

  15. TAPIR--Finnish national geochemical baseline database.

    Science.gov (United States)

    Jarva, Jaana; Tarvainen, Timo; Reinikainen, Jussi; Eklund, Mikael

    2010-09-15

    In Finland, a Government Decree on the Assessment of Soil Contamination and Remediation Needs has generated a need for reliable and readily accessible data on geochemical baseline concentrations in Finnish soils. According to the Decree, baseline concentrations, referring both to the natural geological background concentrations and the diffuse anthropogenic input of substances, shall be taken into account in the soil contamination assessment process. This baseline information is provided in a national geochemical baseline database, TAPIR, that is publicly available via the Internet. Geochemical provinces with elevated baseline concentrations were delineated to provide regional geochemical baseline values. The nationwide geochemical datasets were used to divide Finland into geochemical provinces. Several metals (Co, Cr, Cu, Ni, V, and Zn) showed anomalous concentrations in seven regions that were defined as metal provinces. Arsenic did not follow a similar distribution to any other elements, and four arsenic provinces were separately determined. Nationwide geochemical datasets were not available for some other important elements such as Cd and Pb. Although these elements are included in the TAPIR system, their distribution does not necessarily follow the ones pre-defined for metal and arsenic provinces. Regional geochemical baseline values, presented as upper limit of geochemical variation within the region, can be used as trigger values to assess potential soil contamination. Baseline values have also been used to determine upper and lower guideline values that must be taken into account as a tool in basic risk assessment. If regional geochemical baseline values are available, the national guideline values prescribed in the Decree based on ecological risks can be modified accordingly. The national geochemical baseline database provides scientifically sound, easily accessible and generally accepted information on the baseline values, and it can be used in various

  16. Assessment of local GNSS baselines at co-location sites

    Science.gov (United States)

    Herrera Pinzón, Iván; Rothacher, Markus

    2018-01-01

    As one of the major contributors to the realisation of the International Terrestrial Reference System (ITRS), the Global Navigation Satellite Systems (GNSS) are prone to suffer from irregularities and discontinuities in time series. While often associated with hardware/software changes and the influence of the local environment, these discrepancies constitute a major threat for ITRS realisations. Co-located GNSS at fundamental sites, with two or more available instruments, provide the opportunity to mitigate their influence while improving the accuracy of estimated positions by examining data breaks, local biases, deformations, time-dependent variations and the comparison of GNSS baselines with existing local tie measurements. With the use of co-located GNSS data from a subset sites of the International GNSS Service network, this paper discusses a global multi-year analysis with the aim of delivering homogeneous time series of coordinates to analyse system-specific error sources in the local baselines. Results based on the comparison of different GNSS-based solutions with the local survey ties show discrepancies of up to 10 mm despite GNSS coordinate repeatabilities at the sub-mm level. The discrepancies are especially large for the solutions using the ionosphere-free linear combination and estimating tropospheric zenith delays, thus corresponding to the processing strategy used for global solutions. Snow on the antennas causes further problems and seasonal variations of the station coordinates. These demonstrate the need for a permanent high-quality monitoring of the effects present in the short GNSS baselines at fundamental sites.

  17. Baseline glucocorticoids are drivers of body mass gain in a diving seabird.

    Science.gov (United States)

    Hennin, Holly L; Wells-Berlin, Alicia M; Love, Oliver P

    2016-03-01

    Life-history trade-offs are influenced by variation in individual state, with individuals in better condition often completing life-history stages with greater success. Although resource accrual significantly impacts key life-history decisions such as the timing of reproduction, little is known about the underlying mechanisms driving resource accumulation. Baseline corticosterone (CORT, the primary avian glucocorticoid) mediates daily and seasonal energetics, responds to changes in food availability, and has been linked to foraging behavior, making it a strong potential driver of individual variation in resource accrual and deposition. Working with a captive colony of white-winged scoters (Melanitta fusca deglandi), we aimed to causally determine whether variation in baseline CORT drives individual body mass gains mediated through fattening rate (plasma triglycerides corrected for body mass). We implanted individuals with each of three treatment pellets to elevate CORT within a baseline range in a randomized order: control, low dose of CORT, high dose of CORT, then blood sampled and recorded body mass over a two-week period to track changes in baseline CORT, body mass, and fattening rates. The high CORT treatment significantly elevated levels of plasma hormone for a short period of time within the biologically relevant, baseline range for this species, but importantly did not inhibit the function of the HPA (hypothalamic-pituitary-adrenal) axis. Furthermore, an elevation in baseline CORT resulted in a consistent increase in body mass throughout the trial period compared to controls. This is some of the first empirical evidence demonstrating that elevations of baseline CORT within a biologically relevant range have a causal, direct, and positive influence on changes in body mass.

  18. Baseline glucocorticoids are drivers of body mass gain in a diving seabird

    Science.gov (United States)

    Hennin, Holly; Berlin, Alicia; Love, Oliver P.

    2016-01-01

    Life-history trade-offs are influenced by variation in individual state, with individuals in better condition often completing life-history stages with greater success. Although resource accrual significantly impacts key life-history decisions such as the timing of reproduction, little is known about the underlying mechanisms driving resource accumulation. Baseline corticosterone (CORT, the primary avian glucocorticoid) mediates daily and seasonal energetics, responds to changes in food availability, and has been linked to foraging behavior, making it a strong potential driver of individual variation in resource accrual and deposition. Working with a captive colony of white-winged scoters (Melanitta fusca deglandi), we aimed to causally determine whether variation in baseline CORT drives individual body mass gains mediated through fattening rate (plasma triglycerides corrected for body mass). We implanted individuals with each of three treatment pellets to elevate CORT within a baseline range in a randomized order: control, low dose of CORT, high dose of CORT, then blood sampled and recorded body mass over a two-week period to track changes in baseline CORT, body mass, and fattening rates. The high CORT treatment significantly elevated levels of plasma hormone for a short period of time within the biologically relevant, baseline range for this species, but importantly did not inhibit the function of the HPA (hypothalamic–pituitary–adrenal) axis. Furthermore, an elevation in baseline CORT resulted in a consistent increase in body mass throughout the trial period compared to controls. This is some of the first empirical evidence demonstrating that elevations of baseline CORT within a biologically relevant range have a causal, direct, and positive influence on changes in body mass.

  19. Geodesy by radio interferometry - Determinations of baseline vector, earth rotation, and solid earth tide parameters with the Mark I very long baseline radio interferometery system

    Science.gov (United States)

    Ryan, J. W.; Clark, T. A.; Coates, R. J.; Ma, C.; Wildes, W. T.

    1986-01-01

    Thirty-seven very long baseline radio interferometry experiments performed between 1972 and 1978 are analyzed and estimates of baseline vectors between six sites, five in the continental United States and one in Europe are derived. No evidence of significant changes in baseline length is found. For example, with a statistical level of confidence of approximately 85 percent, upper bounds on such changes within the United States ranged from a low of 10 mm/yr for the 850 km baseline between Westford, Massachusetts, and Green Bank, West Virginia, to a high of 90 mm/yr for the nearly 4000 km baseline between Westford and Goldstone, California. Estimates for universal time and for the x component of the position of the earth's pole are obtained. For the last 15 experiments, the only ones employing wideband receivers, the root-mean-square differences between the derived values and the corresponding ones published by the Bureau International de l'Heure are 0.0012 s and 0.018 arc sec respectively. The average value obtained for the radial Love number for the solid earth is 0.62 + or - 0.02 (estimated standard error).

  20. Effects of baseline conditions on the simulated hydrologic response to projected climate change

    Science.gov (United States)

    Koczot, Kathryn M.; Markstrom, Steven L.; Hay, Lauren E.

    2011-01-01

    Changes in temperature and precipitation projected from five general circulation models, using one late-twentieth-century and three twenty-first-century emission scenarios, were downscaled to three different baseline conditions. Baseline conditions are periods of measured temperature and precipitation data selected to represent twentieth-century climate. The hydrologic effects of the climate projections are evaluated using the Precipitation-Runoff Modeling System (PRMS), which is a watershed hydrology simulation model. The Almanor Catchment in the North Fork of the Feather River basin, California, is used as a case study. Differences and similarities between PRMS simulations of hydrologic components (i.e., snowpack formation and melt, evapotranspiration, and streamflow) are examined, and results indicate that the selection of a specific time period used for baseline conditions has a substantial effect on some, but not all, hydrologic variables. This effect seems to be amplified in hydrologic variables, which accumulate over time, such as soil-moisture content. Results also indicate that uncertainty related to the selection of baseline conditions should be evaluated using a range of different baseline conditions. This is particularly important for studies in basins with highly variable climate, such as the Almanor Catchment.

  1. Baseline distortion effect on gamma-ray pulse-height spectra in neutron capture experiments

    International Nuclear Information System (INIS)

    Laptev, A.; Harada, H.; Nakamura, S.; Hori, J.; Igashira, M.; Ohsaki, T.; Ohgama, K.

    2005-01-01

    A baseline distortion effect due to gamma-flash at neutron time-of-flight measurement using a pulse neutron source has been investigated. Pulses from C 6 D 6 detectors accumulated by flash-ADC were processed with both standard analog-to-digital converter (ADC) and flash-ADC operational modes. A correction factor of gamma-ray yields, due to baseline shift, was quantitatively obtained by comparing the pulse height spectra of the two data-taking modes. The magnitude of the correction factor depends on the time after gamma-flash and has complex time dependence with a changing sign

  2. Baseline Vascular Cognitive Impairment Predicts the Course of Apathetic Symptoms After Stroke: The CASPER Study.

    Science.gov (United States)

    Douven, Elles; Köhler, Sebastian; Schievink, Syenna H J; van Oostenbrugge, Robert J; Staals, Julie; Verhey, Frans R J; Aalten, Pauline

    2018-03-01

    To examine the influence of vascular cognitive impairment (VCI) on the course of poststroke depression (PSD) and poststroke apathy (PSA). Included were 250 stroke patients who underwent neuropsychological and neuropsychiatric assessment 3 months after stroke (baseline) and at a 6- and 12-month follow-up after baseline. Linear mixed models tested the influence of VCI in at least one cognitive domain (any VCI) or multidomain VCI (VCI in multiple cognitive domains) at baseline and domain-specific VCI at baseline on levels of depression and apathy over time, with random effects for intercept and slope. Almost half of the patients showed any VCI at baseline, and any VCI was associated with increasing apathy levels from baseline to the 12-month follow-up. Patients with multidomain VCI had higher apathy scores at the 6- and 12-month follow-up compared with patients with VCI in a single cognitive domain. Domain-specific analyses showed that impaired executive function and slowed information processing speed went together with increasing apathy levels from baseline to 6- and 12-month follow-up. None of the cognitive variables predicted the course of depressive symptoms. Baseline VCI is associated with increasing apathy levels from baseline to the chronic stroke phase, whereas no association was found between baseline VCI and the course of depressive symptoms. Health professionals should be aware that apathy might be absent early after stroke but may evolve over time in patients with VCI. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  3. 40 CFR 1042.825 - Baseline determination.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Baseline determination. 1042.825... Provisions for Remanufactured Marine Engines § 1042.825 Baseline determination. (a) For the purpose of this... not valid. (f) Use good engineering judgment for all aspects of the baseline determination. We may...

  4. Oscillation Baselining and Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-27

    PNNL developed a new tool for oscillation analysis and baselining. This tool has been developed under a new DOE Grid Modernization Laboratory Consortium (GMLC) Project (GM0072 - “Suite of open-source applications and models for advanced synchrophasor analysis”) and it is based on the open platform for PMU analysis. The Oscillation Baselining and Analysis Tool (OBAT) performs the oscillation analysis and identifies modes of oscillations (frequency, damping, energy, and shape). The tool also does oscillation event baselining (fining correlation between oscillations characteristics and system operating conditions).

  5. 33 CFR 2.20 - Territorial sea baseline.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line.... Normally, the territorial sea baseline is the mean low water line along the coast of the United States...

  6. Program Baseline Change Control Board charter

    International Nuclear Information System (INIS)

    1993-02-01

    The purpose of this Charter is to establish the Program Baseline Change Control Board (PBCCB) for the Office of Civilian Radioactive Waste Management (OCRWM) Program, and to describe its organization, responsibilities, and basic methods of operation. Guidance for implementing this Charter is provided by the OCRWM Baseline Management Plan (BMP) and OCRWM Program Baseline Change Control Procedure

  7. Establishing a store baseline during interim storage of waste packages and a review of potential technologies for base-lining

    Energy Technology Data Exchange (ETDEWEB)

    McTeer, Jennifer; Morris, Jenny; Wickham, Stephen [Galson Sciences Ltd. Oakham, Rutland (United Kingdom); Bolton, Gary [National Nuclear Laboratory Risley, Warrington (United Kingdom); McKinney, James; Morris, Darrell [Nuclear Decommissioning Authority Moor Row, Cumbria (United Kingdom); Angus, Mike [National Nuclear Laboratory Risley, Warrington (United Kingdom); Cann, Gavin; Binks, Tracey [National Nuclear Laboratory Sellafield (United Kingdom)

    2013-07-01

    Interim storage is an essential component of the waste management lifecycle, providing a safe, secure environment for waste packages awaiting final disposal. In order to be able to monitor and detect change or degradation of the waste packages, storage building or equipment, it is necessary to know the original condition of these components (the 'waste storage system'). This paper presents an approach to establishing the baseline for a waste-storage system, and provides guidance on the selection and implementation of potential base-lining technologies. The approach is made up of two sections; assessment of base-lining needs and definition of base-lining approach. During the assessment of base-lining needs a review of available monitoring data and store/package records should be undertaken (if the store is operational). Evolutionary processes (affecting safety functions), and their corresponding indicators, that can be measured to provide a baseline for the waste-storage system should then be identified in order for the most suitable indicators to be selected for base-lining. In defining the approach, identification of opportunities to collect data and constraints is undertaken before selecting the techniques for base-lining and developing a base-lining plan. Base-lining data may be used to establish that the state of the packages is consistent with the waste acceptance criteria for the storage facility and to support the interpretation of monitoring and inspection data collected during store operations. Opportunities and constraints are identified for different store and package types. Technologies that could potentially be used to measure baseline indicators are also reviewed. (authors)

  8. Pediatric Heart Transplantation: Transitioning to Adult Care (TRANSIT): Baseline Findings.

    Science.gov (United States)

    Grady, Kathleen L; Hof, Kathleen Van't; Andrei, Adin-Cristian; Shankel, Tamara; Chinnock, Richard; Miyamoto, Shelley; Ambardekar, Amrut V; Anderson, Allen; Addonizio, Linda; Latif, Farhana; Lefkowitz, Debra; Goldberg, Lee; Hollander, Seth A; Pham, Michael; Weissberg-Benchell, Jill; Cool, Nichole; Yancy, Clyde; Pahl, Elfriede

    2018-02-01

    Young adult solid organ transplant recipients who transfer from pediatric to adult care experience poor outcomes related to decreased adherence to the medical regimen. Our pilot trial for young adults who had heart transplant (HT) who transfer to adult care tests an intervention focused on increasing HT knowledge, self-management and self-advocacy skills, and enhancing support, as compared to usual care. We report baseline findings between groups regarding (1) patient-level outcomes and (2) components of the intervention. From 3/14 to 9/16, 88 subjects enrolled and randomized to intervention (n = 43) or usual care (n = 45) at six pediatric HT centers. Patient self-report questionnaires and medical records data were collected at baseline, and 3 and 6 months after transfer. For this report, baseline findings (at enrollment and prior to transfer to adult care) were analyzed using Chi-square and t-tests. Level of significance was p Baseline demographics were similar in the intervention and usual care arms: age 21.3 ± 3.2 vs 21.5 ± 3.3 years and female 44% vs 49%, respectively. At baseline, there were no differences between intervention and usual care for use of tacrolimus (70 vs 62%); tacrolimus level (mean ± SD = 6.5 ± 2.3 ng/ml vs 5.6 ± 2.3 ng/ml); average of the within patient standard deviation of the baseline mean tacrolimus levels (1.6 vs 1.3); and adherence to the medical regimen [3.6 ± 0.4 vs 3.5 ± 0.5 (1 = hardly ever to 4 = all of the time)], respectively. At baseline, both groups had a modest amount of HT knowledge, were learning self-management and self-advocacy, and perceived they were adequately supported. Baseline findings indicate that transitioning HT recipients lack essential knowledge about HT and have incomplete self-management and self-advocacy skills.

  9. Baseline and annual repeat rounds of screening. Implications for optimal regimens of screening

    Energy Technology Data Exchange (ETDEWEB)

    Henschke, Claudia I.; Salvatore, Mary; Cham, Matthew; Eber, Corey; Yip, Rowena; Yankelevitz, David F. [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Powell, Charles A.; DiFabrizio, Larry [Icahn School of Medicine at Mount Sinai, Department of Medicine, New York, NY (United States); Flores, Raja; Kaufman, Andrew [Icahn School of Medicine at Mount Sinai, Department of Thoracic Surgery, New York, NY (United States); Collaboration: International Early Lung Cancer Action Program Investigators

    2018-03-15

    Differences in results of baseline and subsequent annual repeat rounds provide important information for optimising the regimen of screening. A prospective cohort study of 65,374 was reviewed to examine the frequency/percentages of the largest noncalcified nodule (NCN), lung cancer cell types and Kaplan-Meier (K-M) survival rates, separately for baseline and annual rounds. Of 65,374 baseline screenings, NCNs were identified in 28,279 (43.3%); lung cancer in 737 (1.1%). Of 74,482 annual repeat screenings, new NCNs were identified in 4959 (7%); lung cancer in 179 (0.24%). Only adenocarcinoma was diagnosed in subsolid NCNs. Percentages of lung cancers by cell type were significantly different (p < 0.0001) in the baseline round compared with annual rounds, reflecting length bias, as were the ratios, reflecting lead times. Long-term K-M survival rate was 100% for typical carcinoids and for adenocarcinomas manifesting as subsolid NCNs; 85% (95% CI 81-89%) for adenocarcinoma, 74% (95% CI 63-85%) for squamous cell, 48% (95% CI 34-62%) for small cell. The rank ordering by lead time was the same as the rank ordering by survival rates. The significant differences in the frequency of NCNs and frequency and aggressiveness of diagnosed cancers in baseline and annual repeat need to be recognised for an optimal regimen of screening. (orig.)

  10. The Effect of Pretest Exercise on Baseline Computerized Neurocognitive Test Scores.

    Science.gov (United States)

    Pawlukiewicz, Alec; Yengo-Kahn, Aaron M; Solomon, Gary

    2017-10-01

    Baseline neurocognitive assessment plays a critical role in return-to-play decision making following sport-related concussions. Prior studies have assessed the effect of a variety of modifying factors on neurocognitive baseline test scores. However, relatively little investigation has been conducted regarding the effect of pretest exercise on baseline testing. The aim of our investigation was to determine the effect of pretest exercise on baseline Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores in adolescent and young adult athletes. We hypothesized that athletes undergoing self-reported strenuous exercise within 3 hours of baseline testing would perform more poorly on neurocognitive metrics and would report a greater number of symptoms than those who had not completed such exercise. Cross-sectional study; Level of evidence, 3. The ImPACT records of 18,245 adolescent and young adult athletes were retrospectively analyzed. After application of inclusion and exclusion criteria, participants were dichotomized into groups based on a positive (n = 664) or negative (n = 6609) self-reported history of strenuous exercise within 3 hours of the baseline test. Participants with a positive history of exercise were then randomly matched, based on age, sex, education level, concussion history, and hours of sleep prior to testing, on a 1:2 basis with individuals who had reported no pretest exercise. The baseline ImPACT composite scores of the 2 groups were then compared. Significant differences were observed for the ImPACT composite scores of verbal memory, visual memory, reaction time, and impulse control as well as for the total symptom score. No significant between-group difference was detected for the visual motor composite score. Furthermore, pretest exercise was associated with a significant increase in the overall frequency of invalid test results. Our results suggest a statistically significant difference in ImPACT composite scores between

  11. Hazard Baseline Downgrade Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    1998-01-01

    This Hazard Baseline Downgrade reviews the Effluent Treatment Facility, in accordance with Department of Energy Order 5480.23, WSRC11Q Facility Safety Document Manual, DOE-STD-1027-92, and DOE-EM-STD-5502-94. It provides a baseline grouping based on the chemical and radiological hazards associated with the facility. The Determination of the baseline grouping for ETF will aid in establishing the appropriate set of standards for the facility

  12. Framework for ensuring appropriate maintenance of baseline PSA and risk monitor models in a nuclear power plant

    International Nuclear Information System (INIS)

    Vrbanic, I.; Sorman, J.

    2005-01-01

    The necessity of observing both long term and short term risk changes many times imposes the need for a nuclear power plant to have a baseline PSA model to produce an estimate of long term averaged risk and a risk monitor to produce a time-dependent risk curve and/or safety functions status at points in time or over a shorter time period of interest. By nature, a baseline PSA reflects plant systems and operation in terms of average conditions and provides time-invariant quantitative risk metrics. Risk monitor, on the other hand, requires condition-specific modeling to produce a quantitative and/or qualitative estimate of plant's condition-specific risk metrics. While risk monitor is used for computing condition-specific risk metrics over time, a baseline PSA model is needed for variety of other risk oriented applications, such as assessments of proposed design modifications or risk ranking of equipment. Having in mind their importance and roles, it is essential that both models, i.e. baseline PSA model and risk monitor are maintained in the way that they represent, as accurately as practically achievable, the actual plant status (e.g. systems' design and plant's procedures in effect) and its history (e.g. numbers of equipment failures and demands that influence relevant PSA parameters). Paper discusses the requirements for appropriate maintenance of plant's baseline PSA model and risk monitor model and presents the framework for plant's engineering and administrative procedures that would ensure they are met. (author)

  13. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method.

    Science.gov (United States)

    Shen, Yueqian; Lindenbergh, Roderik; Wang, Jinhu

    2016-12-24

    A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.

  14. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method

    Directory of Open Access Journals (Sweden)

    Yueqian Shen

    2016-12-01

    Full Text Available A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.

  15. Atmospheric pressure loading parameters from very long baseline interferometry observations

    Science.gov (United States)

    Macmillan, D. S.; Gipson, John M.

    1994-01-01

    Atmospheric mass loading produces a primarily vertical displacement of the Earth's crust. This displacement is correlated with surface pressure and is large enough to be detected by very long baseline interferometry (VLBI) measurements. Using the measured surface pressure at VLBI stations, we have estimated the atmospheric loading term for each station location directly from VLBI data acquired from 1979 to 1992. Our estimates of the vertical sensitivity to change in pressure range from 0 to -0.6 mm/mbar depending on the station. These estimates agree with inverted barometer model calculations (Manabe et al., 1991; vanDam and Herring, 1994) of the vertical displacement sensitivity computed by convolving actual pressure distributions with loading Green's functions. The pressure sensitivity tends to be smaller for stations near the coast, which is consistent with the inverted barometer hypothesis. Applying this estimated pressure loading correction in standard VLBI geodetic analysis improves the repeatability of estimated lengths of 25 out of 37 baselines that were measured at least 50 times. In a root-sum-square (rss) sense, the improvement generally increases with baseline length at a rate of about 0.3 to 0.6 ppb depending on whether the baseline stations are close to the coast. For the 5998-km baseline from Westford, Massachusetts, to Wettzell, Germany, the rss improvement is about 3.6 mm out of 11.0 mm. The average rss reduction of the vertical scatter for inland stations ranges from 2.7 to 5.4 mm.

  16. Development of an approach to correcting MicroPEM baseline drift.

    Science.gov (United States)

    Zhang, Ting; Chillrud, Steven N; Pitiranggon, Masha; Ross, James; Ji, Junfeng; Yan, Beizhan

    2018-07-01

    Fine particulate matter (PM 2.5 ) is associated with various adverse health outcomes. The MicroPEM (RTI, NC), a miniaturized real-time portable particulate sensor with an integrated filter for collecting particles, has been widely used for personal PM 2.5 exposure assessment. Five-day deployments were targeted on a total of 142 deployments (personal or residential) to obtain real-time PM 2.5 levels from children living in New York City and Baltimore. Among these 142 deployments, 79 applied high-efficiency particulate air (HEPA) filters in the field at the beginning and end of each deployment to adjust the zero level of the nephelometer. However, unacceptable baseline drift was observed in a large fraction (> 40%) of acquisitions in this study even after HEPA correction. This drift issue has been observed in several other studies as well. The purpose of the present study is to develop an algorithm to correct the baseline drift in MicroPEM based on central site ambient data during inactive time periods. A running baseline & gravimetric correction (RBGC) method was developed based on the comparison of MicroPEM readings during inactive periods to ambient PM 2.5 levels provided by fixed monitoring sites and the gravimetric weight of PM 2.5 collected on the MicroPEM filters. The results after RBGC correction were compared with those using HEPA approach and gravimetric correction alone. Seven pairs of duplicate acquisitions were used to validate the RBGC method. The percentages of acquisitions with baseline drift problems were 42%, 53% and 10% for raw, HEPA corrected, and RBGC corrected data, respectively. Pearson correlation analysis of duplicates showed an increase in the coefficient of determination from 0.75 for raw data to 0.97 after RBGC correction. In addition, the slope of the regression line increased from 0.60 for raw data to 1.00 after RBGC correction. The RBGC approach corrected the baseline drift issue associated with MicroPEM data. The algorithm developed

  17. Denosumab and bone metastasis-free survival in men with nonmetastatic castration-resistant prostate cancer: exploratory analyses by baseline prostate-specific antigen doubling time.

    Science.gov (United States)

    Smith, Matthew R; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-10-20

    Denosumab, an anti-RANK ligand monoclonal antibody, significantly increases bone metastasis-free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression.

  18. 10 CFR 850.20 - Baseline beryllium inventory.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Baseline beryllium inventory. 850.20 Section 850.20 Energy... Baseline beryllium inventory. (a) The responsible employer must develop a baseline inventory of the... inventory, the responsible employer must: (1) Review current and historical records; (2) Interview workers...

  19. 40 CFR 80.92 - Baseline auditor requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Baseline auditor requirements. 80.92... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Anti-Dumping § 80.92 Baseline auditor requirements. (a... determination methodology, resulting baseline fuel parameter, volume and emissions values verified by an auditor...

  20. Mechanical Thrombectomy in Elderly Stroke Patients with Mild-to-Moderate Baseline Disability.

    Science.gov (United States)

    Slawski, Diana E; Salahuddin, Hisham; Shawver, Julie; Kenmuir, Cynthia L; Tietjen, Gretchen E; Korsnack, Andrea; Zaidi, Syed F; Jumaa, Mouhammad A

    2018-04-01

    The number of elderly patients suffering from ischemic stroke is rising. Randomized trials of mechanical thrombectomy (MT) generally exclude patients over the age of 80 years with baseline disability. The aim of this study was to understand the efficacy and safety of MT in elderly patients, many of whom may have baseline impairment. Between January 2015 and April 2017, 96 patients ≥80 years old who underwent MT for stroke were selected for a chart review. The data included baseline characteristics, time to treatment, the rate of revascularization, procedural complications, mortality, and 90-day good outcome defined as a modified Rankin Scale (mRS) score of 0-2 or return to baseline. Of the 96 patients, 50 had mild baseline disability (mRS score 0-1) and 46 had moderate disability (mRS score 2-4). Recanalization was achieved in 84% of the patients, and the rate of symptomatic hemorrhage was 6%. At 90 days, 34% of the patients had a good outcome. There were no significant differences in good outcome between those with mild and those with moderate baseline disability (43 vs. 24%, p = 0.08), between those aged ≤85 and those aged > 85 years (40.8 vs. 26.1%, p = 0.19), and between those treated within and those treated beyond 8 h (39 vs. 20%, p = 0.1). The mortality rate was 38.5% at 90 days. The Alberta Stroke Program Early CT Score (ASPECTS) and the National Institutes of Health Stroke Scale (NIHSS) predicted good outcome regardless of baseline disability ( p baseline disability, and delayed treatment are associated with sub-optimal outcomes after MT. However, redefining good outcome to include return to baseline functioning demonstrates that one-third of this patient population benefits from MT, suggesting the real-life utility of this treatment.

  1. Physics with a very long neutrino factory baseline

    International Nuclear Information System (INIS)

    Gandhi, Raj; Winter, Walter

    2007-01-01

    We discuss the neutrino oscillation physics of a very long neutrino factory baseline over a broad range of lengths (between 6000 km and 9000 km), centered on the 'magic baseline' (∼7500 km) where correlations with the leptonic CP phase are suppressed by matter effects. Since the magic baseline depends only on the density, we study the impact of matter density profile effects and density uncertainties over this range, and the impact of detector locations off the optimal baseline. We find that the optimal constant density describing the physics over this entire baseline range is about 5% higher than the average matter density. This implies that the magic baseline is significantly shorter than previously inferred. However, while a single detector optimization requires fine-tuning of the (very long) baseline length, its combination with a near detector at a shorter baseline is much less sensitive to the far detector location and to uncertainties in the matter density. In addition, we point out different applications of this baseline which go beyond its excellent correlation and degeneracy resolution potential. We demonstrate that such a long baseline assists in the improvement of the θ 13 precision and in the resolution of the octant degeneracy. Moreover, we show that the neutrino data from such a baseline could be used to extract the matter density along the profile up to 0.24% at 1σ for large sin 2 2θ 13 , providing a useful discriminator between different geophysical models

  2. Development Of Regional Climate Mitigation Baseline For A DominantAgro-Ecological Zone Of Karnataka, India

    Energy Technology Data Exchange (ETDEWEB)

    Sudha, P.; Shubhashree, D.; Khan, H.; Hedge, G.T.; Murthy, I.K.; Shreedhara, V.; Ravindranath, N.H.

    2007-06-01

    Setting a baseline for carbon stock changes in forest andland use sector mitigation projects is an essential step for assessingadditionality of the project. There are two approaches for settingbaselines namely, project-specific and regional baseline. This paperpresents the methodology adopted for estimating the land available formitigation, for developing a regional baseline, transaction cost involvedand a comparison of project-specific and regional baseline. The studyshowed that it is possible to estimate the potential land and itssuitability for afforestation and reforestation mitigation projects,using existing maps and data, in the dry zone of Karnataka, southernIndia. The study adopted a three-step approach for developing a regionalbaseline, namely: i) identification of likely baseline options for landuse, ii) estimation of baseline rates of land-use change, and iii)quantification of baseline carbon profile over time. The analysis showedthat carbon stock estimates made for wastelands and fallow lands forproject-specific as well as the regional baseline are comparable. Theratio of wasteland Carbon stocks of a project to regional baseline is1.02, and that of fallow lands in the project to regional baseline is0.97. The cost of conducting field studies for determination of regionalbaseline is about a quarter of the cost of developing a project-specificbaseline on a per hectare basis. The study has shown the reliability,feasibility and cost-effectiveness of adopting regional baseline forforestry sectormitigation projects.

  3. Scanner baseliner monitoring and control in high volume manufacturing

    Science.gov (United States)

    Samudrala, Pavan; Chung, Woong Jae; Aung, Nyan; Subramany, Lokesh; Gao, Haiyong; Gomez, Juan-Manuel

    2016-03-01

    We analyze performance of different customized models on baseliner overlay data and demonstrate the reduction in overlay residuals by ~10%. Smart Sampling sets were assessed and compared with the full wafer measurements. We found that performance of the grid can still be maintained by going to one-third of total sampling points, while reducing metrology time by 60%. We also demonstrate the feasibility of achieving time to time matching using scanner fleet manager and thus identify the tool drifts even when the tool monitoring controls are within spec limits. We also explore the scanner feedback constant variation with illumination sources.

  4. The deterioration of signal to noise ratio due to baseline restoration

    International Nuclear Information System (INIS)

    Henein, K.L.

    1976-02-01

    The deterioration of signal to noise ratio due to baseline restoration is theoretically studied. This study brings to the conclusion that a restorer has negligible influence on the signal to noise ratio when its time constant is ten times greater than that of the main amplifier filter, and that the rapid restorers prevail over the slow ones when the time constant of the filter is increased by at least 50% of its optimal value [fr

  5. Large-baseline InSAR for precise topographic mapping: a framework for TanDEM-X large-baseline data

    Directory of Open Access Journals (Sweden)

    M. Pinheiro

    2017-09-01

    Full Text Available The global Digital Elevation Model (DEM resulting from the TanDEM-X mission provides information about the world topography with outstanding precision. In fact, performance analysis carried out with the already available data have shown that the global product is well within the requirements of 10 m absolute vertical accuracy and 2 m relative vertical accuracy for flat to moderate terrain. The mission's science phase took place from October 2014 to December 2015. During this phase, bistatic acquisitions with across-track separation between the two satellites up to 3.6 km at the equator were commanded. Since the relative vertical accuracy of InSAR derived elevation models is, in principle, inversely proportional to the system baseline, the TanDEM-X science phase opened the doors for the generation of elevation models with improved quality with respect to the standard product. However, the interferometric processing of the large-baseline data is troublesome due to the increased volume decorrelation and very high frequency of the phase variations. Hence, in order to fully profit from the increased baseline, sophisticated algorithms for the interferometric processing, and, in particular, for the phase unwrapping have to be considered. This paper proposes a novel dual-baseline region-growing framework for the phase unwrapping of the large-baseline interferograms. Results from two experiments with data from the TanDEM-X science phase are discussed, corroborating the expected increased level of detail of the large-baseline DEMs.

  6. Denosumab and Bone Metastasis–Free Survival in Men With Nonmetastatic Castration-Resistant Prostate Cancer: Exploratory Analyses by Baseline Prostate-Specific Antigen Doubling Time

    Science.gov (United States)

    Smith, Matthew R.; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-01-01

    Purpose Denosumab, an anti–RANK ligand monoclonal antibody, significantly increases bone metastasis–free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. Patients and Methods A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. Results In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Conclusion Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression. PMID:24043751

  7. The TDAQ Baseline Architecture

    CERN Multimedia

    Wickens, F J

    The Trigger-DAQ community is currently busy preparing material for the DAQ, HLT and DCS TDR. Over the last few weeks a very important step has been a series of meetings to complete agreement on the baseline architecture. An overview of the architecture indicating some of the main parameters is shown in figure 1. As reported at the ATLAS Plenary during the February ATLAS week, the main area where the baseline had not yet been agreed was around the Read-Out System (ROS) and details in the DataFlow. The agreed architecture has: Read-Out Links (ROLs) from the RODs using S-Link; Read-Out Buffers (ROB) sited near the RODs, mounted in a chassis - today assumed to be a PC, using PCI bus at least for configuration, control and monitoring. The baseline assumes data aggregation, in the ROB and/or at the output (which could either be over a bus or in the network). Optimization of the data aggregation will be made in the coming months, but the current model has each ROB card receiving input from 4 ROLs, and 3 such c...

  8. Forest baseline and deforestation map of the Dominican Republic through the analysis of time series of MODIS data

    Directory of Open Access Journals (Sweden)

    Florencia Sangermano

    2015-09-01

    Full Text Available Deforestation is one of the major threats to habitats in the Dominican Republic. In this work we present a forest baseline for the year 2000 and a deforestation map for the year 2011. Maps were derived from Moderate Resolution Imaging Radiometer (MODIS products at 250 m resolution. The vegetation continuous fields product (MOD44B for the year 2000 was used to produce the forest baseline, while the vegetation indices product (MOD13Q1 was used to detect change between 2000 and 2011. Major findings based on the data presented here are reported in the manuscript “Habitat suitability and protection status of four species of amphibians in the Dominican Republic” (Sangermano et al., Appl. Geogr., [7].63, 2015, 55–65

  9. Baseline Estimation and Outlier Identification for Halocarbons

    Science.gov (United States)

    Wang, D.; Schuck, T.; Engel, A.; Gallman, F.

    2017-12-01

    The aim of this paper is to build a baseline model for halocarbons and to statistically identify the outliers under specific conditions. In this paper, time series of regional CFC-11 and Chloromethane measurements was discussed, which taken over the last 4 years at two locations, including a monitoring station at northwest of Frankfurt am Main (Germany) and Mace Head station (Ireland). In addition to analyzing time series of CFC-11 and Chloromethane, more importantly, a statistical approach of outlier identification is also introduced in this paper in order to make a better estimation of baseline. A second-order polynomial plus harmonics are fitted to CFC-11 and chloromethane mixing ratios data. Measurements with large distance to the fitting curve are regard as outliers and flagged. Under specific requirement, the routine is iteratively adopted without the flagged measurements until no additional outliers are found. Both model fitting and the proposed outlier identification method are realized with the help of a programming language, Python. During the period, CFC-11 shows a gradual downward trend. And there is a slightly upward trend in the mixing ratios of Chloromethane. The concentration of chloromethane also has a strong seasonal variation, mostly due to the seasonal cycle of OH. The usage of this statistical method has a considerable effect on the results. This method efficiently identifies a series of outliers according to the standard deviation requirements. After removing the outliers, the fitting curves and trend estimates are more reliable.

  10. Leveraging probabilistic peak detection to estimate baseline drift in complex chromatographic samples.

    Science.gov (United States)

    Lopatka, Martin; Barcaru, Andrei; Sjerps, Marjan J; Vivó-Truyols, Gabriel

    2016-01-29

    Accurate analysis of chromatographic data often requires the removal of baseline drift. A frequently employed strategy strives to determine asymmetric weights in order to fit a baseline model by regression. Unfortunately, chromatograms characterized by a very high peak saturation pose a significant challenge to such algorithms. In addition, a low signal-to-noise ratio (i.e. s/npeak detection algorithm. A posterior probability of being affected by a peak is computed for each point in the chromatogram, leading to a set of weights that allow non-iterative calculation of a baseline estimate. For extremely saturated chromatograms, the peak weighted (PW) method demonstrates notable improvement compared to the other methods examined. However, in chromatograms characterized by low-noise and well-resolved peaks, the asymmetric least squares (ALS) and the more sophisticated Mixture Model (MM) approaches achieve superior results in significantly less time. We evaluate the performance of these three baseline correction methods over a range of chromatographic conditions to demonstrate the cases in which each method is most appropriate. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Baseline Tumor Lipiodol Uptake after Transarterial Chemoembolization for Hepatocellular Carcinoma: Identification of a Threshold Value Predicting Tumor Recurrence.

    Science.gov (United States)

    Matsui, Yusuke; Horikawa, Masahiro; Jahangiri Noudeh, Younes; Kaufman, John A; Kolbeck, Kenneth J; Farsad, Khashayar

    2017-12-01

    The aim of the study was to evaluate the association between baseline Lipiodol uptake in hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) with early tumor recurrence, and to identify a threshold baseline uptake value predicting tumor response. A single-institution retrospective database of HCC treated with Lipiodol-TACE was reviewed. Forty-six tumors in 30 patients treated with a Lipiodol-chemotherapy emulsion and no additional particle embolization were included. Baseline Lipiodol uptake was measured as the mean Hounsfield units (HU) on a CT within one week after TACE. Washout rate was calculated dividing the difference in HU between the baseline CT and follow-up CT by time (HU/month). Cox proportional hazard models were used to correlate baseline Lipiodol uptake and other variables with tumor response. A receiver operating characteristic (ROC) curve was used to identify the optimal threshold for baseline Lipiodol uptake predicting tumor response. During the follow-up period (mean 5.6 months), 19 (41.3%) tumors recurred (mean time to recurrence = 3.6 months). In a multivariate model, low baseline Lipiodol uptake and higher washout rate were significant predictors of early tumor recurrence ( P = 0.001 and Baseline Lipiodol uptake and washout rate on follow-up were independent predictors of early tumor recurrence. A threshold value of baseline Lipiodol uptake > 270.2 HU was highly sensitive and specific for tumor response. These findings may prove useful for determining subsequent treatment strategies after Lipiodol TACE.

  12. Effect of Enamel Caries Lesion Baseline Severity on Fluoride Dose-Response

    Directory of Open Access Journals (Sweden)

    Frank Lippert

    2017-01-01

    Full Text Available This study aimed to investigate the effect of enamel caries lesion baseline severity on fluoride dose-response under pH cycling conditions. Early caries lesions were created in human enamel specimens at four different severities (8, 16, 24, and 36 h. Lesions were allocated to treatment groups (0, 83, and 367 ppm fluoride as sodium fluoride based on Vickers surface microhardness (VHN and pH cycled for 5 d. The cycling model comprised 3 × 1 min fluoride treatments sandwiched between 2 × 60 min demineralization challenges with specimens stored in artificial saliva in between. VHN was measured again and changes versus lesion baseline were calculated (ΔVHN. Data were analyzed using two-way ANOVA (p<0.05. Increased demineralization times led to increased surface softening. The lesion severity×fluoride concentration interaction was significant (p<0.001. Fluoride dose-response was observed in all groups. Lesions initially demineralized for 16 and 8 h showed similar overall rehardening (ΔVHN and more than 24 and 36 h lesions, which were similar. The 8 h lesions showed the greatest fluoride response differential (367 versus 0 ppm F which diminished with increasing lesion baseline severity. The extent of rehardening as a result of the 0 ppm F treatment increased with increasing lesion baseline severity, whereas it decreased for the fluoride treatments. In conclusion, lesion baseline severity impacts the extent of the fluoride dose-response.

  13. Way to increase the user access at the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg; Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2010-10-15

    Although the LCLS photon beam is meant for a single user, the baseline undulator is long enough to serve two users simultaneously. To this end, we propose a setup composed of two simple elements: an X-ray mirror pair for X-ray beam deflection, and a short (4 m-long) magnetic chicane, which creates an offset for mirror pair installation in the middle of the baseline undulator. The insertable mirror pair can be used for spatial separation of the X-ray beams generated in the first and in the second half of the baseline undulator. The method of deactivating one half and activating another half of the undulator is based on the rapid switching of the FEL amplification process. As proposed elsewhere, using a kicker installed upstream of the LCLS baseline undulator and an already existing corrector in the first half of the undulator, it is possible to rapidly switch the X-ray beam from one user to another, thus providing two active beamlines at any time. We present simulation results dealing with the LCLS baseline, and show that it is possible to generate two saturated SASE X-ray beams in the whole 0.8-8 keV photon energy range in the same baseline undulator. These can be exploited to serve two users. Implementation of the proposed technique does not perturb the baseline mode of operation of the LCLS undulator. Moreover, the magnetic chicane setup is very flexible, and can be used as a self-seeding setup too. We present simulation results for the LCLS baseline undulator with SHAB (second harmonic afterburner) and show that one can produce monochromatic radiation at the 2nd harmonic as well as at the 1st. We describe an efficient way for obtaining multi-user operation at the LCLS hard X-ray FEL. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezoelectric devices similar to those for X-ray phase retarders

  14. Infrared thermometry and the crop water stress index. I. History, theory, and baselines

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Development of portable infrared thermometers and the definition of the Crop Water Stress Index (CWSI) have led to widespread interest in infrared thermometry to monitor water stress and schedule irrigations. But the CWSI concept is still new and poorly understood by many. The purpose of this paper is to review the definition of CWSI, and the determination and interpretation of the non-water-stressed baselines used to compute CWSI. The non-water-stressed baseline equation normalizes the canopy minus air temperature differential for variations in vapor pressure deficit. Non-water-stressed baselines can be determined empirically from measurements of canopy and air temperatures and vapor pressure deficit, made diurnally on a single day, or at a single time of day over many days, on well-watered plants. The value of the maximum canopy minus air temperature differential under maximum water stress should also be determined empirically. Causes for CWSI values falling outside of the defined 0 to 10 unit range are reviewed. Non-water-stressed baselines may shift with plant growth stage. Effective use of CWSI is dependent on understanding the definition of CWSI, and the proper determination and use of non-water-stressed baselines. (author)

  15. Classifying vulnerability to sleep deprivation using baseline measures of psychomotor vigilance.

    Science.gov (United States)

    Patanaik, Amiya; Kwoh, Chee Keong; Chua, Eric C P; Gooley, Joshua J; Chee, Michael W L

    2015-05-01

    To identify measures derived from baseline psychomotor vigilance task (PVT) performance that can reliably predict vulnerability to sleep deprivation. Subjects underwent total sleep deprivation and completed a 10-min PVT every 1-2 h in a controlled laboratory setting. Participants were categorized as vulnerable or resistant to sleep deprivation, based on a median split of lapses that occurred following sleep deprivation. Standard reaction time, drift diffusion model (DDM), and wavelet metrics were derived from PVT response times collected at baseline. A support vector machine model that incorporated maximum relevance and minimum redundancy feature selection and wrapper-based heuristics was used to classify subjects as vulnerable or resistant using rested data. Two academic sleep laboratories. Independent samples of 135 (69 women, age 18 to 25 y), and 45 (3 women, age 22 to 32 y) healthy adults. In both datasets, DDM measures, number of consecutive reaction times that differ by more than 250 ms, and two wavelet features were selected by the model as features predictive of vulnerability to sleep deprivation. Using the best set of features selected in each dataset, classification accuracy was 77% and 82% using fivefold stratified cross-validation, respectively. In both datasets, DDM measures, number of consecutive reaction times that differ by more than 250 ms, and two wavelet features were selected by the model as features predictive of vulnerability to sleep deprivation. Using the best set of features selected in each dataset, classification accuracy was 77% and 82% using fivefold stratified cross-validation, respectively. Despite differences in experimental conditions across studies, drift diffusion model parameters associated reliably with individual differences in performance during total sleep deprivation. These results demonstrate the utility of drift diffusion modeling of baseline performance in estimating vulnerability to psychomotor vigilance decline

  16. Long Baseline Observatory (LBO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Long Baseline Observatory (LBO) comprises ten radio telescopes spanning 5,351 miles. It's the world's largest, sharpest, dedicated telescope array. With an eye...

  17. Hanford Site technical baseline database. Revision 1

    International Nuclear Information System (INIS)

    Porter, P.E.

    1995-01-01

    This report lists the Hanford specific files (Table 1) that make up the Hanford Site Technical Baseline Database. Table 2 includes the delta files that delineate the differences between this revision and revision 0 of the Hanford Site Technical Baseline Database. This information is being managed and maintained on the Hanford RDD-100 System, which uses the capabilities of RDD-100, a systems engineering software system of Ascent Logic Corporation (ALC). This revision of the Hanford Site Technical Baseline Database uses RDD-100 version 3.0.2.2 (see Table 3). Directories reflect those controlled by the Hanford RDD-100 System Administrator. Table 4 provides information regarding the platform. A cassette tape containing the Hanford Site Technical Baseline Database is available

  18. 75 FR 66748 - Notice of Baseline Filings

    Science.gov (United States)

    2010-10-29

    ...- 000] Notice of Baseline Filings October 22, 2010. ONEOK Gas Transportation, L.L.C Docket No. PR11-68... above submitted a revised baseline filing of their Statement of Operating Conditions for services...

  19. An Improved Rank Correlation Effect Size Statistic for Single-Case Designs: Baseline Corrected Tau.

    Science.gov (United States)

    Tarlow, Kevin R

    2017-07-01

    Measuring treatment effects when an individual's pretreatment performance is improving poses a challenge for single-case experimental designs. It may be difficult to determine whether improvement is due to the treatment or due to the preexisting baseline trend. Tau- U is a popular single-case effect size statistic that purports to control for baseline trend. However, despite its strengths, Tau- U has substantial limitations: Its values are inflated and not bound between -1 and +1, it cannot be visually graphed, and its relatively weak method of trend control leads to unacceptable levels of Type I error wherein ineffective treatments appear effective. An improved effect size statistic based on rank correlation and robust regression, Baseline Corrected Tau, is proposed and field-tested with both published and simulated single-case time series. A web-based calculator for Baseline Corrected Tau is also introduced for use by single-case investigators.

  20. 2016 Annual Technology Baseline (ATB) - Webinar Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley; Kurup, Parthiv; Hand, Maureen; Feldman, David; Sigrin, Benjamin; Lantz, Eric; Stehly, Tyler; Augustine, Chad; Turchi, Craig; Porro, Gian; O' Connor, Patrick; Waldoch, Connor

    2016-09-13

    This deck was presented for the 2016 Annual Technology Baseline Webinar. The presentation describes the Annual Technology Baseline, which is a compilation of current and future cost and performance data for electricity generation technologies.

  1. Baseline Levels, and Changes Over Time in Body Mass Index and Fasting Insulin, and Their Relationship to Change in Metabolic Trait Clustering

    Science.gov (United States)

    Sullivan, Lisa M.; Fox, Caroline S.; Wilson, Peter W.F.; Nathan, David M.; Vasan, Ramachandran S.; D'Agostino, Ralph B.; Meigs, James B.

    2014-01-01

    Abstract Background: Multiple abnormal metabolic traits are found together or “cluster” within individuals more often than is predicted by chance. The individual and combined role of adiposity and insulin resistance (IR) on metabolic trait clustering is uncertain. We tested the hypothesis that change in trait clustering is a function of both baseline level and change in these measures. Methods: In 2616 nondiabetic Framingham Offspring Study participants, body mass index (BMI) and fasting insulin were related to a within-person 7-year change in a trait score of 0–4 Adult Treatment Panel III metabolic syndrome traits (hypertension, high triglycerides, low high-density lipoprotein cholesterol, hyperglycemia). Results: At baseline assessment, mean trait score was 1.4 traits, and 7-year mean (SEM) change in trait score was +0.25 (0.02) traits, Pfasting insulin were similarly related to trait score change. In models adjusted for age–sex–baseline cluster score, 7-year change in trait score was significantly related to both a 1-quintile difference in baseline BMI (0.07 traits) and fasting insulin (0.18 traits), and to both a 1-quintile 7-year increase in BMI (0.21 traits) and fasting insulin (0.18 traits). Conclusions: Change in metabolic trait clustering was significantly associated with baseline levels and changes in both BMI and fasting insulin, highlighting the importance of both obesity and IR in the clustering of metabolic traits. PMID:25007010

  2. Effect of tidal cycle and food intake on the baseline plasma corticosterone rhythm in intertidally foraging marine iguanas.

    Science.gov (United States)

    Woodley, Sarah K; Painter, Danika L; Moore, Michael C; Wikelski, Martin; Romero, L Michael

    2003-06-15

    In most species, plasma levels of baseline glucocorticoids such as corticosterone (B) have a circadian rhythm. This rhythm can be entrained by both photoperiod and food intake and is related to aspects of energy intake and metabolism. Marine iguanas (Amblyrhynchus cristatus) offer a unique opportunity to better understand the relative importance of the light:dark cycle versus food intake in influencing the rhythm in baseline B in a natural system. Compared to other species, food intake is not as strictly determined by the phase of the light:dark cycle. Animals feed in the intertidal zone so feeding activity is heavily influenced by the tidal cycle. We measured baseline plasma B levels in free-living iguanas over several 24-h periods that varied in the timing of low tide/foraging activity. We found that baseline B levels were higher during the day relative to night. However, when low tide occurred during the day, baseline B levels dropped coincident with the timing of low tide. Whether the baseline B rhythm (including the drop during foraging) is an endogenous rhythm with a circatidal component, or is simply a result of feeding and associated physiological changes needs to be tested. Together, these data suggest that the baseline B rhythm in marine iguanas is influenced by the tidal cycle/food intake as well as the light:dark cycle.

  3. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, B.C.; Menne, T.; Johansen, J.D.

    2008-01-01

    Background: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. Objectives: To examine associations of 21 allergens in the European baseline series to polysensitization....... Patients/Methods: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. Results...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization Udgivelsesdato: 2008...

  4. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Menné, Torkil; Johansen, Jeanne Duus

    2008-01-01

    BACKGROUND: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. OBJECTIVES: To examine associations of 21 allergens in the European baseline series to polysensitization....... PATIENTS/METHODS: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. RESULTS...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization....

  5. TWRS technical baseline database manager definition document

    International Nuclear Information System (INIS)

    Acree, C.D.

    1997-01-01

    This document serves as a guide for using the TWRS Technical Baseline Database Management Systems Engineering (SE) support tool in performing SE activities for the Tank Waste Remediation System (TWRS). This document will provide a consistent interpretation of the relationships between the TWRS Technical Baseline Database Management software and the present TWRS SE practices. The Database Manager currently utilized is the RDD-1000 System manufactured by the Ascent Logic Corporation. In other documents, the term RDD-1000 may be used interchangeably with TWRS Technical Baseline Database Manager

  6. Baseline neurocognitive testing in sports-related concussions: the importance of a prior night's sleep.

    Science.gov (United States)

    McClure, D Jake; Zuckerman, Scott L; Kutscher, Scott J; Gregory, Andrew J; Solomon, Gary S

    2014-02-01

    The management of sports-related concussions (SRCs) utilizes serial neurocognitive assessments and self-reported symptom inventories to assess recovery and safety for return to play (RTP). Because postconcussive RTP goals include symptom resolution and a return to neurocognitive baseline levels, clinical decisions rest in part on understanding modifiers of this baseline. Several studies have reported age and sex to influence baseline neurocognitive performance, but few have assessed the potential effect of sleep. We chose to investigate the effect of reported sleep duration on baseline Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) performance and the number of patient-reported symptoms. We hypothesized that athletes receiving less sleep before baseline testing would perform worse on neurocognitive metrics and report more symptoms. Cross-sectional study; Level of evidence, 3. We retrospectively reviewed 3686 nonconcussed athletes (2371 male, 1315 female; 3305 high school, 381 college) with baseline symptom and ImPACT neurocognitive scores. Patients were stratified into 3 groups based on self-reported sleep duration the night before testing: (1) short, sleep duration on baseline ImPACT performance. A univariate ANCOVA was performed to investigate the influence of sleep on total self-reported symptoms. When controlling for age and sex as covariates, the MANCOVA revealed significant group differences on ImPACT reaction time, verbal memory, and visual memory scores but not visual-motor (processing) speed scores. An ANCOVA also revealed significant group differences in total reported symptoms. For baseline symptoms and ImPACT scores, subsequent pairwise comparisons revealed these associations to be most significant when comparing the short and intermediate sleep groups. Our results indicate that athletes sleeping fewer than 7 hours before baseline testing perform worse on 3 of 4 ImPACT scores and report more symptoms. Because SRC management and RTP

  7. Business-as-Unusual: Existing policies in energy model baselines

    International Nuclear Information System (INIS)

    Strachan, Neil

    2011-01-01

    Baselines are generally accepted as a key input assumption in long-term energy modelling, but energy models have traditionally been poor on identifying baselines assumptions. Notably, transparency on the current policy content of model baselines is now especially critical as long-term climate mitigation policies have been underway for a number of years. This paper argues that the range of existing energy and emissions policies are an integral part of any long-term baseline, and hence already represent a 'with-policy' baseline, termed here a Business-as-Unusual (BAuU). Crucially, existing energy policies are not a sunk effort; as impacts of existing policy initiatives are targeted at future years, they may be revised through iterative policy making, and their quantitative effectiveness requires ex-post verification. To assess the long-term role of existing policies in energy modelling, currently identified UK policies are explicitly stripped out of the UK MARKAL Elastic Demand (MED) optimisation energy system model, to generate a BAuU (with-policy) and a REF (without policy) baseline. In terms of long-term mitigation costs, policy-baseline assumptions are comparable to another key exogenous modelling assumption - that of global fossil fuel prices. Therefore, best practice in energy modelling would be to have both a no-policy reference baseline, and a current policy reference baseline (BAuU). At a minimum, energy modelling studies should have a transparent assessment of the current policy contained within the baseline. Clearly identifying and comparing policy-baseline assumptions are required for cost effective and objective policy making, otherwise energy models will underestimate the true cost of long-term emissions reductions.

  8. Near Detectors based on gas TPCs for neutrino long baseline experiments

    CERN Document Server

    Blondel, A

    2017-01-01

    Time Projection Chambers have been used with success for the T2K ND280 near detector and are proposed for an upgrade of the T2K near detector. High pressure TPCs are also being considered for future long-baseline experiments like Hyper-Kamiokande and DUNE. A High Pressure TPC would be a very sensitive detector for the detailed study of neutrino-nucleus interactions, a limiting factor for extracting the ultimate precision in long baseline experiments. The requirements of TPCs for neutrino detectors are quite specific. We propose here the development of state-of-the-art near detectors based on gas TPC: atmospheric pressure TPCs for T2K-II and a high-pressure TPC for neutrino experiments. The project proposed here benefits from a strong involvement of the European (CERN) members of the T2K collaboration and beyond. It is a strongly synergetic precursor of other projects of near detectors using gas TPCs that are under discussion for the long baseline neutrino projects worldwide. It will help maintain and develop...

  9. Pakistan, Sindh Province - Baseline Indicators System : Baseline Procurement Performance Assessment Report

    OpenAIRE

    World Bank

    2009-01-01

    This document provides an assessment of the public procurement system in Sindh province using the baseline indicators system developed by the Development Assistance Committee of the Organization for Economic Cooperation and Development (OECD-DAC). This assessment, interviews and discussions were held with stakeholders from the public and private sectors as well as civil society. Developing...

  10. Life Support Baseline Values and Assumptions Document

    Science.gov (United States)

    Anderson, Molly S.; Ewert, Michael K.; Keener, John F.

    2018-01-01

    The Baseline Values and Assumptions Document (BVAD) provides analysts, modelers, and other life support researchers with a common set of values and assumptions which can be used as a baseline in their studies. This baseline, in turn, provides a common point of origin from which many studies in the community may depart, making research results easier to compare and providing researchers with reasonable values to assume for areas outside their experience. This document identifies many specific physical quantities that define life support systems, serving as a general reference for spacecraft life support system technology developers.

  11. A method to establish seismic noise baselines for automated station assessment

    Science.gov (United States)

    McNamara, D.E.; Hutt, C.R.; Gee, L.S.; Benz, H.M.; Buland, R.P.

    2009-01-01

    We present a method for quantifying station noise baselines and characterizing the spectral shape of out-of-nominal noise sources. Our intent is to automate this method in order to ensure that only the highest-quality data are used in rapid earthquake products at NEIC. In addition, the station noise baselines provide a valuable tool to support the quality control of GSN and ANSS backbone data and metadata. The procedures addressed here are currently in development at the NEIC, and work is underway to understand how quickly changes from nominal can be observed and used within the NEIC processing framework. The spectral methods and software used to compute station baselines and described herein (PQLX) can be useful to both permanent and portable seismic stations operators. Applications include: general seismic station and data quality control (QC), evaluation of instrument responses, assessment of near real-time communication system performance, characterization of site cultural noise conditions, and evaluation of sensor vault design, as well as assessment of gross network capabilities (McNamara et al. 2005). Future PQLX development plans include incorporating station baselines for automated QC methods and automating station status report generation and notification based on user-defined QC parameters. The PQLX software is available through the USGS (http://earthquake. usgs.gov/research/software/pqlx.php) and IRIS (http://www.iris.edu/software/ pqlx/).

  12. Carbon emission coefficient of power consumption in India: baseline determination from the demand side

    International Nuclear Information System (INIS)

    Nag, Barnali; Parikh, J.K.

    2005-01-01

    Substantial investments are expected in the Indian power sector under the flexibility mechanisms (CDM/JI) laid down in Article 12 of the Kyoto Protocol. In this context it is important to evolve a detailed framework for baseline construction in the power sector so as to incorporate the major factors that would affect the baseline values directly or indirectly. It is also important to establish carbon coefficients from electricity generation to help consider accurate project boundaries for numerous electricity conservation and DSM schemes. The objective of this paper is to provide (i) time series estimates of indirect carbon emissions per unit of power consumption (which can also be thought of as emission coefficient of power consumption) and (ii) baseline emissions for the power sector till 2015. Annual time series data on Indian electricity generating industry, for 1974-1998, has been used to develop emission projections till 2015. The impacts of generation mix, fuel efficiency, transmission and distribution losses and auxiliary consumption are studied in a Divisia decomposition framework and their possible future impacts on baseline emissions are studied through three scenarios of growth in power consumption. The study also estimates and projects the carbon emission coefficient per unit of final consumption of electricity that can be used for conducting cost benefit of emission reduction potential for several electricity conserving technologies and benchmarking policy models

  13. Factors Contributing to Disparities in Baseline Neurocognitive Performance and Concussion Symptom Scores Between Black and White Collegiate Athletes.

    Science.gov (United States)

    Wallace, Jessica; Covassin, Tracey; Moran, Ryan; Deitrick, Jamie McAllister

    2017-11-02

    National Collegiate Athletic Association (NCAA) concussion guidelines state that all NCAA athletes must have a concussion baseline test prior to commencing their competitive season. To date, little research has examined potential racial differences on baseline neurocognitive performance among NCAA athletes. The purpose of this study was to investigate differences between Black and White collegiate athletes on baseline neurocognitive performance and self-reported symptoms. A total of 597 collegiate athletes (400 White, 197 Black) participated in this study. Athletes self-reported their race on the demographic section of their pre-participation physical examination and were administered the Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) neurocognitive battery in a supervised, quiet room. Controlling for sex, data were analyzed using separate one-way analyses of covariance (ANCOVAs) on symptom score, verbal and visual memory, visual motor processing speed, and reaction time composite scores. Results revealed significant differences between White and Black athletes on baseline symptom score (F (1,542)  = 5.82, p = .01), visual motor processing speed (F (1,542)  = 14.89, p baseline visual motor processing speed and reaction time. Black athletes reported higher baseline symptom scores compared to Whites. There was no statistical difference between race on verbal memory (p = .08) and that on visual memory (p = .06). Black athletes demonstrated disparities on some neurocognitive measures at baseline. These results suggest capturing an individual baseline on each athlete, as normative data comparisons may be inappropriate for athletes of a racial minority.

  14. FAQs about Baseline Testing among Young Athletes

    Science.gov (United States)

    ... a similar exam conducted by a health care professional during the season if an athlete has a suspected concussion. Baseline testing generally takes place during the pre-season—ideally prior to the first practice. It is important to note that some baseline ...

  15. 75 FR 74706 - Notice of Baseline Filings

    Science.gov (United States)

    2010-12-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Baseline Filings November 24, 2010. Centana Intrastate Pipeline, LLC. Docket No. PR10-84-001. Centana Intrastate Pipeline, LLC... applicants listed above submitted a revised baseline filing of their Statement of Operating Conditions for...

  16. Geochemical baseline studies of soil in Finland

    Science.gov (United States)

    Pihlaja, Jouni

    2017-04-01

    The soil element concentrations regionally vary a lot in Finland. Mostly this is caused by the different bedrock types, which are reflected in the soil qualities. Geological Survey of Finland (GTK) is carrying out geochemical baseline studies in Finland. In the previous phase, the research is focusing on urban areas and mine environments. The information can, for example, be used to determine the need for soil remediation, to assess environmental impacts or to measure the natural state of soil in industrial areas or mine districts. The field work is done by taking soil samples, typically at depth between 0-10 cm. Sampling sites are chosen to represent the most vulnerable areas when thinking of human impacts by possible toxic soil element contents: playgrounds, day-care centers, schools, parks and residential areas. In the mine districts the samples are taken from the areas locating outside the airborne dust effected areas. Element contents of the soil samples are then analyzed with ICP-AES and ICP-MS, Hg with CV-AAS. The results of the geochemical baseline studies are published in the Finnish national geochemical baseline database (TAPIR). The geochemical baseline map service is free for all users via internet browser. Through this map service it is possible to calculate regional soil baseline values using geochemical data stored in the map service database. Baseline data for 17 elements in total is provided in the map service and it can be viewed on the GTK's web pages (http://gtkdata.gtk.fi/Tapir/indexEN.html).

  17. Baseliner: An open-source, interactive tool for processing sap flux data from thermal dissipation probes

    Directory of Open Access Journals (Sweden)

    A. Christopher Oishi

    2016-01-01

    Full Text Available Estimating transpiration from woody plants using thermal dissipation sap flux sensors requires careful data processing. Currently, researchers accomplish this using spreadsheets, or by personally writing scripts for statistical software programs (e.g., R, SAS. We developed the Baseliner software to help establish a standardized protocol for processing sap flux data. Baseliner enables users to QA/QC data and process data using a combination of automated steps, visualization, and manual editing. Data processing requires establishing a zero-flow reference value, or “baseline”, which varies among sensors and with time. Since no set of algorithms currently exists to reliably QA/QC and estimate the zero-flow baseline, Baseliner provides a graphical user interface to allow visual inspection and manipulation of data. Data are first automatically processed using a set of user defined parameters. The user can then view the data for additional, manual QA/QC and baseline identification using mouse and keyboard commands. The open-source software allows for user customization of data processing algorithms as improved methods are developed.

  18. Single-baseline RTK GNSS Positioning for Hydrographic Surveying

    Science.gov (United States)

    Metin Alkan, Reha; Murat Ozulu, I.; Ilçi, Veli; Kahveci, Muzaffer

    2015-04-01

    Positioning with GNSS technique can be carried out in two ways, absolute and relative. It has been possible to reach a few meters absolute point positioning accuracies in real time after disabling SA permanently in May 2000. Today, accuracies obtainable from absolute point positioning using code observations are not sufficient for most surveying applications. Thus to meet higher accuracy requirements, differential methods using single or dual frequency geodetic-grade GNSS receivers that measure carrier phase have to be used. However, this method requires time-cost field and office works and if the measurement is not carried out with conventional RTK method, user needs a GNSS data processing software to estimate the coordinates. If RTK is used, at least two or more GNSS receivers are required, one as a reference and the other as a rover. Moreover, the distance between the receivers must not exceed 15-20 km in order to be able to rapidly and reliably resolve the carrier phase ambiguities. On the other hand, based on the innovations and improvements in satellite geodesy and GNSS modernization studies occurred within the last decade, many new positioning methods and new approaches have been developed. One of them is Network-RTK (or commonly known as CORS) and the other is Single-baseline RTK. These methods are widely used for many surveying applications in many countries. The user of the system can obtain his/her position within a few cm level of accuracy in real-time with only a single GNSS receiver that has Network RTK (CORS) capability. When compared with the conventional differential and RTK methods, this technique has several significant advantages as it is easy to use and it produces accurate, cost-effective and rapid solutions. In Turkey, establishment of a multi-base RTK network was completed and opened for civilian use in 2009. This network is called CORS-TR and consists of 146 reference stations having about 80-100 km interstation distances. It is possible

  19. Intrafractional baseline drift during free breathing breast cancer radiation therapy.

    Science.gov (United States)

    Jensen, Christer Andre; Acosta Roa, Ana María; Lund, Jo-Åsmund; Frengen, Jomar

    2017-06-01

    Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.

  20. Time of exposure to night work and carotid atherosclerosis: a structural equation modeling approach using baseline data from ELSA-Brasil.

    Science.gov (United States)

    Silva-Costa, Aline; Guimarães, Joanna; Chor, Dora; de Jesus Mendes da Fonseca, Maria; Bensenor, Isabela; Santos, Itamar; Barreto, Sandhi; Griep, Rosane Härter

    2018-04-02

    The study of cardiovascular diseases (CVD) associated with night work is difficult due to the long period required for conditions to manifest and the healthy-worker effect. Analyzing asymptomatic pre-clinical changes in the atherosclerotic process is a way to assess the pathways between exposure to night work and CVD. To evaluate the associations between night work and subclinical atherosclerosis measured by carotid intima-media thickness (CIMT) using baseline data from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil). We conducted cross-sectional analyses using baseline data (2008-2010) from 9785 civil servants, aged 35-74 years. The associations between time of exposure to night work and mean CIMT were examined using a structural equation model. The sample included 4259 men and 5526 women, mean age of 51.6 years. A total of 1778 (18.2%) individuals were exposed to night work (594 current and 1184 former night workers), and the mean years of night work exposed was 11.47 (SD = 9.45) years. On average, mean CIMT was 0.606 (SD = 0.130) mm. Among men, the increase in exposure to night work was significantly associated with an increase in BMI and CIMT. Among women, night work was not associated with increased CIMT. In relation to the indirect associations, results suggest a possible mediation by BMI, diabetes and hypertension on the association between the years of night work and mean CIMT only among men. Night work was associated with increased CIMT only among men. These findings add to the knowledge of the possible pathways that link night work and carotid atherosclerosis. Additionally, these results contribute to the recognition of work schedules as a public health problem that should be addressed by the medical community and policy makers.

  1. Baseline prostate-specific antigen levels following treatment with abiraterone acetate as a prognostic factor in castration-resistant prostate cancer.

    Science.gov (United States)

    Hiroshige, Tasuku; Eguchi, Yoshiro; Yoshizumi, Osamu; Chikui, Katsuaki; Kumagai, Hisaji; Kawaguchi, Yoshihiro; Onishi, Rei; Hayashi, Tokumasa; Watanabe, Kouta; Mitani, Tomotaro; Saito, Koujiro; Igawa, Tsukasa

    2018-05-01

    The aim of the present study was to investigate the prognostic factors associated with progression-free survival (PFS) and overall survival (OS) times in patients with castration-resistant prostate cancer (CRPC) who received treatment with abiraterone acetate (AA) in routine clinical settings. A total of 93 patients treated with AA between September 2014 and February 2017 were selected and their medical records were analyzed retrospectively. The median PFS time of docetaxel (DTX)-naïve patients was 171 days, and that of post-DTX patients was 56 days. The OS time of DTX-naïve patients did not reach the median. The median OS time of post-DTX patients was 761 days. Multivariate analyses identified baseline prostate-specific antigen (PSA) level prior to treatment with AA and the PSA response rate as independent prognostic factors for PFS time, and baseline PSA prior to treatment with AA as the only independent prognostic factor for OS time. The results of the present study indicate that the baseline PSA level prior to treatment with AA is a notable prognostic factor in patients with CRPC.

  2. 75 FR 57268 - Notice of Baseline Filings

    Science.gov (United States)

    2010-09-20

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-103-000; Docket No. PR10-104-000; Docket No. PR10-105- 000 (Not Consolidated)] Notice of Baseline Filings September 13..., 2010, and September 10, 2010, respectively the applicants listed above submitted their baseline filing...

  3. 75 FR 65010 - Notice of Baseline Filings

    Science.gov (United States)

    2010-10-21

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-1-000; Docket No. PR11-2-000; Docket No. PR11-3-000] Notice of Baseline Filings October 14, 2010. Cranberry Pipeline Docket..., 2010, respectively the applicants listed above submitted their baseline filing of its Statement of...

  4. Earth matter effects at very long baselines and the neutrino mass hierarchy

    International Nuclear Information System (INIS)

    Gandhi, Raj; Ghoshal, Pomita; Goswami, Srubabati; Mehta, Poonam; Sankar, S. Uma

    2006-01-01

    We study matter effects which arise in the muon neutrino oscillation and survival probabilities relevant to atmospheric neutrino and very long baseline (>4000 Km) beam experiments. The interrelations between the three probabilities P μe , P μτ , and P μμ are examined. It is shown that large and observable sensitivity to the neutrino mass hierarchy can be present in P μμ and P μτ . We emphasize that at baselines >7000 Km, matter effects in P μτ are important under certain conditions and can be large. The muon survival rates in experiments with very long baselines thus depend on matter effects in both P μτ and P μe . We also indicate where these effects provide sensitivity to θ 13 and identify ranges of energies and baselines where this sensitivity is maximum. The effect of parameter degeneracies in the three probabilities at these baselines and energies is studied in detail and large parts of the parameter space are identified which are free from these degeneracies. In the second part of the paper, we focus on using the matter effects studied in the first part as a means of determining the mass hierarchy via atmospheric neutrinos. Realistic event rate calculations are performed for a charge discriminating 100 kT iron calorimeter which demonstrate the possibility of realizing this very important goal in neutrino physics. It is shown that for atmospheric neutrinos, a careful selection of energy and baseline ranges is necessary in order to obtain a statistically significant signal, and that the effects are largest in bins where matter effects in both P μe and P μτ combine constructively. Under these conditions, up to a 4σ signal for matter effects is possible (for Δ 31 >0) within a time scale appreciably shorter than the one anticipated for neutrino factories

  5. THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

    Energy Technology Data Exchange (ETDEWEB)

    Partnership, ALMA [Astrophysics Research Institute, Liverpool John Moores University, IC2, Liverpool Science Park, 146 Brownlow Hill, Liverpool L3 5RF (United Kingdom); Fomalont, E. B.; Vlahakis, C.; Corder, S.; Remijan, A.; Barkats, D.; Dent, W. R. F.; Phillips, N.; Cox, P.; Hales, A. S. [Joint ALMA Observatory, Alonso de Córdova 3107, Vitacura, Santiago (Chile); Lucas, R. [Institut de Planétologie et d’Astrophysique de Grenoble (UMR 5274), BP 53, F-38041 Grenoble Cedex 9 (France); Hunter, T. R.; Brogan, C. L.; Amestica, R.; Cotton, W. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Asaki, Y. [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Matsushita, S. [Institute of Astronomy and Astrophysics, Academia Sinica, P.O. Box 23-141, Taipei 106, Taiwan (China); Hills, R. E. [Astrophysics Group, Cavendish Laboratory, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Richards, A. M. S. [Jodrell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Broguiere, D., E-mail: efomalon@nrao.edu [Institut de Radioastronomie Millime´trique (IRAM), 300 rue de la Piscine, Domaine Universitaire, F-38406 Saint Martin d’Hères (France); and others

    2015-07-20

    A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy.

  6. THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

    International Nuclear Information System (INIS)

    Partnership, ALMA; Fomalont, E. B.; Vlahakis, C.; Corder, S.; Remijan, A.; Barkats, D.; Dent, W. R. F.; Phillips, N.; Cox, P.; Hales, A. S.; Lucas, R.; Hunter, T. R.; Brogan, C. L.; Amestica, R.; Cotton, W.; Asaki, Y.; Matsushita, S.; Hills, R. E.; Richards, A. M. S.; Broguiere, D.

    2015-01-01

    A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy

  7. Esophageal Baseline Impedance Reflects Mucosal Integrity and Predicts Symptomatic Outcome With Proton Pump Inhibitor Treatment.

    Science.gov (United States)

    Xie, Chenxi; Sifrim, Daniel; Li, Yuwen; Chen, Minhu; Xiao, Yinglian

    2018-01-30

    Esophageal baseline impedance, which is decreased in gastroesophageal reflux disease (GERD) patients, is related to the severity of acid reflux and the integrity of the esophageal mucosa. The study aims to compare the baseline impedance and the dilated intercellular spaces (DIS) within patients with typical reflux symptoms and to evaluate the correlation of baseline impedance with DIS, esophageal acid exposure, as well as the efficacy of proton pump inhibitor (PPI) treatment. Ninety-two patients and 10 healthy controls were included in the study. Erosive esophagitis (EE) was defined by esophageal mucosal erosion under upper endoscopy. Patients without mucosa erosion were divided into groups with pathologic acid reflux (non-erosive reflux disease [NERD]) or with hypersensitive esophagus. The biopsies of esophageal mucosa were taken 2-4 cm above the gastroesophageal junction Z-line during upper endoscopy for DIS measurement. All the patients received esomeprazole 20 mg twice-daily treatment for 8 weeks. The efficacy of esomeprazole was evaluated among all patients. The intercellular spaces were dilated in both EE and NERD patients ( P baseline impedance was decreased in both EE patients and NERD patients, and negatively correlated to the acid exposure time ( r = -0.527, P baseline impedance ( r = -0.230, P Baseline impedance > 1764 Ω" was an independent predictor for PPI failure (OR, 11.9; 95% CI, 2.4-58.9; P baseline impedance was observed in patients with mucosa erosion or pathological acid reflux. The baseline impedance reflected the mucosal integrity, it was more sensitive to esophageal acid exposure. Patients with high impedance might not benefit from the PPI treatment.

  8. 76 FR 8725 - Notice of Baseline Filings

    Science.gov (United States)

    2011-02-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Baseline Filings Enstor Grama Ridge Storage and Docket No. PR10-97-002. Transportation, L.L.C.. EasTrans, LLC Docket No. PR10-30-001... revised baseline filing of their Statement of Operating Conditions for services provided under section 311...

  9. 76 FR 5797 - Notice of Baseline Filings

    Science.gov (United States)

    2011-02-02

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-114-001; Docket No. PR10-129-001; Docket No. PR10-131- 001; Docket No. PR10-68-002 Not Consolidated] Notice of Baseline... applicants listed above submitted a revised baseline filing of their Statement of Operating Conditions for...

  10. Office of Geologic Repositories program baseline procedures notebook (OGR/B-1)

    International Nuclear Information System (INIS)

    1986-06-01

    Baseline management is typically applied to aid in the internal control of a program by providing consistent programmatic direction, control, and surveillance to an evolving system development. This fundamental concept of internal program control involves the establishment of a baseline to serve as a point of departure for consistent technical program coordination and to control subsequent changes from that baseline. The existence of a program-authorized baseline ensures that all participants are working to the same ground rules. Baseline management also ensures that, once the baseline is defined, changes are assessed and approved by a process which ensures adequate consideration of overall program impact. Baseline management also includes the consideration of examptions from the baseline. The process of baseline management continues through all the phases of an evolving system development program. As the Program proceeds, there will be a progressive increase in the data contained in the baseline documentation. Baseline management has been selected as a management technique to aid in the internal control of the Office of Geologic Repositories (OGR) program. Specifically, an OGR Program Baseline, including technical and programmatic requirements, is used for program control of the four Mined Geologic Disposal System field projects, i.e., Basalt Waste Isolation Project, Nevada Nuclear Waste Storage Investigation, Salt Repository Project and Crystalline Repository Project. This OGR Program Baseline Procedures Notebook provides a description of the baseline mwanagement concept, establishes the OGR Program baseline itself, and provides procedures to be followed for controlling changes to that baseline. The notebook has a controlled distribution and will be updated as required

  11. Accelerated Best Basis Inventory Baselining Task

    International Nuclear Information System (INIS)

    SASAKI, L.M.

    2001-01-01

    The baselining effort was recently proposed to bring the Best-Basis Inventory (BBI) and Question No.8 of the Tank Interpretive Report (TIR) for all 177 tanks to the current standards and protocols and to prepare a TIR Question No.8 if one is not already available. This plan outlines the objectives and methodology of the accelerated BBI baselining task. BBI baselining meetings held during December 2000 resulted in a revised BBI methodology and an initial set of BBI creation rules to be used in the baselining effort. The objectives of the BBI baselining effort are to: (1) Provide inventories that are consistent with the revised BBI methodology and new BBI creation rules. (2) Split the total tank waste in each tank into six waste phases, as appropriate (Supernatant, saltcake solids, saltcake liquid, sludge solids, sludge liquid, and retained gas). In some tanks, the solids and liquid portions of the sludge and/or saltcake may be combined into a single sludge or saltcake phase. (3) Identify sampling events that are to be used for calculating the BBIs. (4) Update waste volumes for subsequent reconciliation with the Hanlon (2001) waste tank summary. (5) Implement new waste type templates. (6) Include any sample data that might have been unintentionally omitted in the previous BBI and remove any sample data that should not have been included. Sample data to be used in the BBI must be available on TWINS. (7) Ensure that an inventory value for each standard BBI analyte is provided for each waste component. Sample based inventories for supplemental BBI analytes will be included when available. (8) Provide new means and confidence interval reports if one is not already available and include uncertainties in reporting inventory values

  12. Effects of ignoring baseline on modeling transitions from intact cognition to dementia.

    Science.gov (United States)

    Yu, Lei; Tyas, Suzanne L; Snowdon, David A; Kryscio, Richard J

    2009-07-01

    This paper evaluates the effect of ignoring baseline when modeling transitions from intact cognition to dementia with mild cognitive impairment (MCI) and global impairment (GI) as intervening cognitive states. Transitions among states are modeled by a discrete-time Markov chain having three transient (intact cognition, MCI, and GI) and two competing absorbing states (death and dementia). Transition probabilities depend on two covariates, age and the presence/absence of an apolipoprotein E-epsilon4 allele, through a multinomial logistic model with shared random effects. Results are illustrated with an application to the Nun Study, a cohort of 678 participants 75+ years of age at baseline and followed longitudinally with up to ten cognitive assessments per nun.

  13. 75 FR 70732 - Notice of Baseline Filings

    Science.gov (United States)

    2010-11-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-71-000; Docket No. PR11-72-000; Docket No. PR11-73- 000] Notice of Baseline Filings November 10, 2010. Docket No. PR11-71-000..., 2010, the applicants listed above submitted their baseline filing of their Statement of Operating...

  14. Physics Potential of Long-Baseline Experiments

    Directory of Open Access Journals (Sweden)

    Sanjib Kumar Agarwalla

    2014-01-01

    Full Text Available The discovery of neutrino mixing and oscillations over the past decade provides firm evidence for new physics beyond the Standard Model. Recently, θ13 has been determined to be moderately large, quite close to its previous upper bound. This represents a significant milestone in establishing the three-flavor oscillation picture of neutrinos. It has opened up exciting prospects for current and future long-baseline neutrino oscillation experiments towards addressing the remaining fundamental questions, in particular the type of the neutrino mass hierarchy and the possible presence of a CP-violating phase. Another recent and crucial development is the indication of non-maximal 2-3 mixing angle, causing the octant ambiguity of θ23. In this paper, I will review the phenomenology of long-baseline neutrino oscillations with a special emphasis on sub-leading three-flavor effects, which will play a crucial role in resolving these unknowns. First, I will give a brief description of neutrino oscillation phenomenon. Then, I will discuss our present global understanding of the neutrino mass-mixing parameters and will identify the major unknowns in this sector. After that, I will present the physics reach of current generation long-baseline experiments. Finally, I will conclude with a discussion on the physics capabilities of accelerator-driven possible future long-baseline precision oscillation facilities.

  15. Precise baseline determination for the TanDEM-X mission

    Science.gov (United States)

    Koenig, Rolf; Moon, Yongjin; Neumayer, Hans; Wermuth, Martin; Montenbruck, Oliver; Jäggi, Adrian

    The TanDEM-X mission will strive for generating a global precise Digital Elevation Model (DEM) by way of bi-static SAR in a close formation of the TerraSAR-X satellite, already launched on June 15, 2007, and the TanDEM-X satellite to be launched in May 2010. Both satellites carry the Tracking, Occultation and Ranging (TOR) payload supplied by the GFZ German Research Centre for Geosciences. The TOR consists of a high-precision dual-frequency GPS receiver, called Integrated GPS Occultation Receiver (IGOR), and a Laser retro-reflector (LRR) for precise orbit determination (POD) and atmospheric sounding. The IGOR is of vital importance for the TanDEM-X mission objectives as the millimeter level determination of the baseline or distance between the two spacecrafts is needed to derive meter level accurate DEMs. Within the TanDEM-X ground segment GFZ is responsible for the operational provision of precise baselines. For this GFZ uses two software chains, first its Earth Parameter and Orbit System (EPOS) software and second the BERNESE software, for backup purposes and quality control. In a concerted effort also the German Aerospace Center (DLR) generates precise baselines independently with a dedicated Kalman filter approach realized in its FRNS software. By the example of GRACE the generation of baselines with millimeter accuracy from on-board GPS data can be validated directly by way of comparing them to the intersatellite K-band range measurements. The K-band ranges are accurate down to the micrometer-level and therefore may be considered as truth. Both TanDEM-X baseline providers are able to generate GRACE baselines with sub-millimeter accuracy. By merging the independent baselines by GFZ and DLR, the accuracy can even be increased. The K-band validation however covers solely the along-track component as the K-band data measure just the distance between the two GRACE satellites. In addition they inhibit an un-known bias which must be modelled in the comparison, so the

  16. Baseline Response Levels Are a Nuisance in Infant Contingency Learning

    Science.gov (United States)

    Millar, W. S.; Weir, Catherine

    2015-01-01

    The impact of differences in level of baseline responding on contingency learning in the first year was examined by considering the response acquisition of infants classified into baseline response quartiles. Whereas the three lower baseline groups showed the predicted increment in responding to a contingency, the highest baseline responders did…

  17. A Kalman filter-based short baseline RTK algorithm for single-frequency combination of GPS and BDS.

    Science.gov (United States)

    Zhao, Sihao; Cui, Xiaowei; Guan, Feng; Lu, Mingquan

    2014-08-20

    The emerging Global Navigation Satellite Systems (GNSS) including the BeiDou Navigation Satellite System (BDS) offer more visible satellites for positioning users. To employ those new satellites in a real-time kinematic (RTK) algorithm to enhance positioning precision and availability, a data processing model for the dual constellation of GPS and BDS is proposed and analyzed. A Kalman filter-based algorithm is developed to estimate the float ambiguities for short baseline scenarios. The entire work process of the high-precision algorithm based on the proposed model is deeply investigated in detail. The model is validated with real GPS and BDS data recorded from one zero and two short baseline experiments. Results show that the proposed algorithm can generate fixed baseline output with the same precision level as that of either a single GPS or BDS RTK algorithm. The significantly improved fixed rate and time to first fix of the proposed method demonstrates a better availability and effectiveness on processing multi-GNSSs.

  18. A Kalman Filter-Based Short Baseline RTK Algorithm for Single-Frequency Combination of GPS and BDS

    Directory of Open Access Journals (Sweden)

    Sihao Zhao

    2014-08-01

    Full Text Available The emerging Global Navigation Satellite Systems (GNSS including the BeiDou Navigation Satellite System (BDS offer more visible satellites for positioning users. To employ those new satellites in a real-time kinematic (RTK algorithm to enhance positioning precision and availability, a data processing model for the dual constellation of GPS and BDS is proposed and analyzed. A Kalman filter-based algorithm is developed to estimate the float ambiguities for short baseline scenarios. The entire work process of the high-precision algorithm based on the proposed model is deeply investigated in detail. The model is validated with real GPS and BDS data recorded from one zero and two short baseline experiments. Results show that the proposed algorithm can generate fixed baseline output with the same precision level as that of either a single GPS or BDS RTK algorithm. The significantly improved fixed rate and time to first fix of the proposed method demonstrates a better availability and effectiveness on processing multi-GNSSs.

  19. IPCC Socio-Economic Baseline Dataset

    Data.gov (United States)

    National Aeronautics and Space Administration — The Intergovernmental Panel on Climate Change (IPCC) Socio-Economic Baseline Dataset consists of population, human development, economic, water resources, land...

  20. Baseline methodologies for clean development mechanism projects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M.K. (ed.); Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-15

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  1. Baseline methodologies for clean development mechanism projects

    International Nuclear Information System (INIS)

    Lee, M.K.; Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-01

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  2. Structure of a traditional baseline data system

    Energy Technology Data Exchange (ETDEWEB)

    1976-12-01

    Research was conducted to determine whether appropriate data exist for the development of a comprehensive statistical baseline data system on the human environment in the Athabasca oil sands region of Alberta. The existing data sources pertinent to the target area were first reviewed and discussed. Criteria were selected to assist the evaluation of data, including type of data collected, source, degree of detail, geographic identification, accessibility, and time frame. These criteria allowed assessing whether the data would be amenable to geographically-coded, continuous monitoring systems. It was found that the Statistics Canada Census provided the most detail, the most complete coverage of the target area, the smallest statistical areas, the greatest consistency in data and data collection, and the most regular collection. The local agency collection efforts were generally oriented toward specific goals and the data intended primarily for intra-agency use. The smallest statistical units in these efforts may be too large to be of value to a common small-area system, and data collection agencies did not generally use coterminous boundaries. Recommendations were made to give primary consideration to Statistics Canada data in the initial development of the baseline data system. Further development of such a system depends on the adoption by local agencies of a common small-area system for data collection. 38 refs., 6 figs.

  3. Performance Measurement Baseline Change Request

    Data.gov (United States)

    Social Security Administration — The Performance Measurement Baseline Change Request template is used to document changes to scope, cost, schedule, or operational performance metrics for SSA's Major...

  4. Rapidly shifting environmental baselines among fishers of the Gulf of California

    Science.gov (United States)

    Sáenz-Arroyo, Andrea; Roberts, Callum M; Torre, Jorge; Cariño-Olvera, Micheline; Enríquez-Andrade, Roberto R

    2005-01-01

    Shifting environmental baselines are inter-generational changes in perception of the state of the environment. As one generation replaces another, people's perceptions of what is natural change even to the extent that they no longer believe historical anecdotes of past abundance or size of species. Although widely accepted, this phenomenon has yet to be quantitatively tested. Here we survey three generations of fishers from Mexico's Gulf of California (N=108), where fish populations have declined steeply over the last 60 years, to investigate how far and fast their environmental baselines are shifting. Compared to young fishers, old fishers named five times as many species and four times as many fishing sites as once being abundant/productive but now depleted (Kruskal–Wallis tests, both p<0.001) with no evidence of a slowdown in rates of loss experienced by younger compared to older generations (Kruskal–Wallis test, n.s. in both cases). Old fishers caught up to 25 times as many Gulf grouper Mycteroperca jordani as young fishers on their best ever fishing day (regression r2=0.62, p<0.001). Despite times of plentiful large fish still being within living memory, few young fishers appreciated that large species had ever been common or nearshore sites productive. Such rapid shifts in perception of what is natural help explain why society is tolerant of the creeping loss of biodiversity. They imply a large educational hurdle in efforts to reset expectations and targets for conservation. PMID:16191603

  5. Effect of education and language on baseline concussion screening tests in professional baseball players.

    Science.gov (United States)

    Jones, Nathaniel S; Walter, Kevin D; Caplinger, Roger; Wright, Daniel; Raasch, William G; Young, Craig

    2014-07-01

    The purpose of the present study was to investigate the possible effects of sociocultural influences, specifically pertaining to language and education, on baseline neuropsychological concussion testing as obtained via immediate postconcussion assessment and cognitive testing (ImPACT) of players from a professional baseball team. A retrospective chart review. Baseline testing of a professional baseball organization. Four hundred five professional baseball players. Age, languages spoken, hometown country location (United States/Canada vs overseas), and years of education. The 5 ImPACT composite scores (verbal memory, visual memory, visual motor speed, reaction time, impulse control) and ImPACT total symptom score from the initial baseline testing. The result of t tests revealed significant differences (P education, the significant differences (P < 0.05) remained in some scores. Sociocultural differences may result in differences in computer-based neuropsychological testing scores.

  6. An Automated Baseline Correction Method Based on Iterative Morphological Operations.

    Science.gov (United States)

    Chen, Yunliang; Dai, Liankui

    2018-05-01

    Raman spectra usually suffer from baseline drift caused by fluorescence or other reasons. Therefore, baseline correction is a necessary and crucial step that must be performed before subsequent processing and analysis of Raman spectra. An automated baseline correction method based on iterative morphological operations is proposed in this work. The method can adaptively determine the structuring element first and then gradually remove the spectral peaks during iteration to get an estimated baseline. Experiments on simulated data and real-world Raman data show that the proposed method is accurate, fast, and flexible for handling different kinds of baselines in various practical situations. The comparison of the proposed method with some state-of-the-art baseline correction methods demonstrates its advantages over the existing methods in terms of accuracy, adaptability, and flexibility. Although only Raman spectra are investigated in this paper, the proposed method is hopefully to be used for the baseline correction of other analytical instrumental signals, such as IR spectra and chromatograms.

  7. Rationing with baselines

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    2013-01-01

    We introduce a new operator for general rationing problems in which, besides conflicting claims, individual baselines play an important role in the rationing process. The operator builds onto ideas of composition, which are not only frequent in rationing, but also in related problems...... such as bargaining, choice, and queuing. We characterize the operator and show how it preserves some standard axioms in the literature on rationing. We also relate it to recent contributions in such literature....

  8. Baseline prevalence and predictors of liver fibrosis among HIV-positive individuals

    DEFF Research Database (Denmark)

    Matthews, G V; Neuhaus, J; Bhagani, S

    2015-01-01

    OBJECTIVES: Liver disease is increasingly recognized in HIV-positive individuals, even among those without viral hepatitis, partly as a result of the recent availability of noninvasive methods of liver fibrosis assessment. The objective of this substudy is to compare the effects of early versus...... deferred antiretroviral therapy (ART) on liver fibrosis progression. METHODS: Sites in the Strategic Timing of AntiRetroviral Treatment (START) study with access to FibroScan® were invited to participate in the Liver Fibrosis Progression Substudy. All substudy participants underwent FibroScan® at baseline......, and two noninvasive serum algorithms, APRI and FIB-4, were calculated. Demographic and liver-related information was collected for all START participants at baseline. RESULTS: A total of 230 participants were enrolled in the substudy (11.5% with hepatitis B or C virus coinfection), of whom 221 had a valid...

  9. 200-UP-2 Operable Unit technical baseline report

    International Nuclear Information System (INIS)

    Deford, D.H.

    1991-02-01

    This report is prepared in support of the development of a Remedial Investigation/Feasibility Study (RI/FS) Work Plan for the 200-UP-2 Operable Unit by EBASCO Environmental, Incorporated. It provides a technical baseline of the 200-UP-2 Operable Unit and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The 200-UP-2 Operable Unit Technical Baseline Report is based on review and evaluation of numerous Hanford Site current and historical reports, Hanford Site drawings and photographs and is supplemented with Hanford Site inspections and employee interviews. No field investigations or sampling were conducted. Each waste site in the 200-UP-2 Operable Unit is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. The 200-UP-2 Operable Unit consists of liquid-waste disposal sites in the vicinity of, and related to, U Plant operations in the 200 West Area of the Hanford Site. The ''U Plant'' refers to the 221-U Process Canyon Building, a chemical separations facility constructed during World War 2. It also includes the Uranium Oxide (UO 3 ) Plant, which was constructed at the same time and, like the 221-U Process Canyon Building, was later converted for other missions. Waste sites in the 200-UP-2 Operable Unit are associated with the U Plant Uranium Metal Recovery Program mission that occurred between 1952 and 1958 and the UO 3 Plant's ongoing uranium oxide mission and include one or more cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, waste vaults, and the lines and encasements that connect them. 11 refs., 1 tab

  10. Mercury baseline levels in Flemish soils (Belgium)

    International Nuclear Information System (INIS)

    Tack, Filip M.G.; Vanhaesebroeck, Thomas; Verloo, Marc G.; Van Rompaey, Kurt; Ranst, Eric van

    2005-01-01

    It is important to establish contaminant levels that are normally present in soils to provide baseline data for pollution studies. Mercury is a toxic element of concern. This study was aimed at assessing baseline mercury levels in soils in Flanders. In a previous study, mercury contents in soils in Oost-Vlaanderen were found to be significantly above levels reported elsewhere. For the current study, observations were extended over two more provinces, West-Vlaanderen and Antwerpen. Ranges of soil Hg contents were distinctly higher in the province Oost-Vlaanderen (interquartile range from 0.09 to 0.43 mg/kg) than in the other provinces (interquartile ranges from 0.7 to 0.13 and 0.7 to 0.15 mg/kg for West-Vlaanderen and Antwerpen, respectively). The standard threshold method was applied to separate soils containing baseline levels of Hg from the data. Baseline concentrations for Hg were characterised by a median of 0.10 mg Hg/kg dry soil, an interquartile range from 0.07 to 0.14 mg/kg and a 90% percentile value of 0.30 mg/kg. The influence of soil properties such as clay and organic carbon contents, and pH on baseline Hg concentrations was not important. Maps of the spatial distribution of Hg levels showed that the province Oost-Vlaanderen exhibited zones with systematically higher Hg soil contents. This may be related to the former presence of many small-scale industries employing mercury in that region. - Increased mercury levels may reflect human activity

  11. Gravity sensing using Very Long Baseline Atom Interferometry

    Science.gov (United States)

    Schlippert, D.; Wodey, E.; Meiners, C.; Tell, D.; Schubert, C.; Ertmer, W.; Rasel, E. M.

    2017-12-01

    Very Long Baseline Atom Interferometry (VLBAI) has applications in high-accuracy absolute gravimetry, gravity-gradiometry, and for tests of fundamental physics. Thanks to the quadratic scaling of the phase shift with increasing free evolution time, extending the baseline of atomic gravimeters from tens of centimeters to meters puts resolutions of 10-13g and beyond in reach.We present the design and progress of key elements of the VLBAI-test stand: a dual-species source of Rb and Yb, a high-performance two-layer magnetic shield, and an active vibration isolation system allowing for unprecedented stability of the mirror acting as an inertial reference. We envisage a vibration-limited short-term sensitivity to gravitational acceleration of 1x10-8 m/s-2Hz-1/2 and up to a factor of 25 improvement when including additional correlation with a broadband seismometer. Here, the supreme long-term stability of atomic gravity sensors opens the route towards competition with superconducting gravimeters. The operation of VLBAI as a differential dual-species gravimeter using ultracold mixtures of Yb and Rb atoms enables quantum tests of the universality of free fall (UFF) at an unprecedented level of <10-13, potentially surpassing the best experiments to date.

  12. Tank waste remediation system technical baseline summary description

    International Nuclear Information System (INIS)

    Raymond, R.E.

    1998-01-01

    This document is one of the tools used to develop and control the mission work as depicted in the included figure. This Technical Baseline Summary Description document is the top-level tool for management of the Technical Baseline for waste storage operations

  13. Carbon tetrachloride ERA soil-gas baseline monitoring

    International Nuclear Information System (INIS)

    Fancher, J.D.

    1994-01-01

    From December 1991 through December 1993, Westinghouse Hanford Company performed routine baseline monitoring of selected wells ad soil-gas points twice weekly in the 200 West Area of the Hanford Site. This work supported the carbon Tetrachloride Expedited Response Action (ERA) and provided a solid baseline of volatile organic compound (VOC) concentrations in wells and in the subsurface at the ERA site. As site remediation continues, comparisons to this baseline can be one means of measuring the success of carbon tetrachloride vapor extraction. This report contains observations of the patterns and trends associated with data obtained during soil-gas monitoring at the 200 West Area: Monitoring performed since late 1991 includes monitoring soil-gas probes ad wellheads for volatile organic compounds (VOCs). This report reflects monitoring data collected from December 1991 through December 1993

  14. Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.

    Science.gov (United States)

    Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu

    2018-04-01

    Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.

  15. Markers and residual time to AIDS

    NARCIS (Netherlands)

    Geskus, R. B.

    2002-01-01

    The value of immunological and virological markers as predictors of progression to AIDS, or death by AIDS, is a topic of much current interest. Mostly, the influence of markers is investigated in a time-dependent or a baseline proportional hazard model, relating time-varying or baseline marker

  16. 324 Building Baseline Radiological Characterization

    Energy Technology Data Exchange (ETDEWEB)

    R.J. Reeder, J.C. Cooper

    2010-06-24

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  17. Digital baseline estimation method for multi-channel pulse height analyzing

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun

    2005-01-01

    The basic features of digital baseline estimation for multi-channel pulse height analysis are introduced. The weight-function of minimum-noise baseline filter is deduced with functional variational calculus. The frequency response of this filter is also deduced with Fourier transformation, and the influence of parameters on amplitude frequency response characteristics is discussed. With MATLAB software, the noise voltage signal from the charge sensitive preamplifier is simulated, and the processing effect of minimum-noise digital baseline estimation is verified. According to the results of this research, digital baseline estimation method can estimate baseline optimally, and it is very suitable to be used in digital multi-channel pulse height analysis. (authors)

  18. Baseline Cerebral Small Vessel Disease Is Not Associated with Gait Decline After Five Years

    NARCIS (Netherlands)

    Van Der Holst, Helena M.; Van Uden, Ingeborg W.M.; de Laat, Karlijn F.; Van Leijsen, Esther M.C.; van Norden, Anouk G.W.; Norris, David G.; Van DIjk, Ewoud J.; Tuladhar, Anil M.; de Leeuw, Frank-Erik

    2017-01-01

    Background Cerebral small vessel disease (SVD) is cross-sectionally associated with gait disturbances, however, the relation between baseline SVD and gait decline over time is uncertain. Furthermore, diffusion tensor imaging (DTI) studies on gait decline are currently lacking. Objective To

  19. First Grade Baseline Evaluation

    Science.gov (United States)

    Center for Innovation in Assessment (NJ1), 2013

    2013-01-01

    The First Grade Baseline Evaluation is an optional tool that can be used at the beginning of the school year to help teachers get to know the reading and language skills of each student. The evaluation is composed of seven screenings. Teachers may use the entire evaluation or choose to use those individual screenings that they find most beneficial…

  20. Cost-effective way to enhance the capabilities of the LCLS baseline

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-08-01

    This paper discusses the potential for enhancing the LCLS hard X-ray FEL capabilities. In the hard X-ray regime, a high longitudinal coherence will be the key to such performance upgrade. The method considered here to obtain high longitudinal coherence is based on a novel single-bunch self-seeding scheme exploiting a single crystal monochromator, which is extremely compact and can be straightforwardly installed in the LCLS baseline undulator. We present simulation results dealing with the LCLS hard X-ray FEL, and show that this method can produce fully-coherent X-ray pulses at 100 GW power level. With the radiation beam monochromatized down to the Fourier transform limit, a variety of very different techniques leading to further improvements of the LCLS performance become feasible. In particular, we describe an efficient way for obtaining full polarization control at the LCLS hard X-ray FEL. We also propose to exploit crystals in the Bragg reflection geometry as movable deflectors for the LCLS X-ray transport systems. The hard X-ray beam can be deflected of an angle of order of a radian without perturbations. The monochromatization of the output radiation constitutes the key for reaching such result. Finally, we describe a newoptical pump - hard X-ray probe technique which will allow time-resolved studies at the LCLS baseline on the femtosecond time scale. The principle of operation of the proposed scheme is essentially based on the use of the time jitter between pump and probe pulses. This eliminates the need for timing XFELs to high-power conventional lasers with femtosecond accuracy. (orig.)

  1. Cost-effective way to enhance the capabilities of the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2010-08-15

    This paper discusses the potential for enhancing the LCLS hard X-ray FEL capabilities. In the hard X-ray regime, a high longitudinal coherence will be the key to such performance upgrade. The method considered here to obtain high longitudinal coherence is based on a novel single-bunch self-seeding scheme exploiting a single crystal monochromator, which is extremely compact and can be straightforwardly installed in the LCLS baseline undulator. We present simulation results dealing with the LCLS hard X-ray FEL, and show that this method can produce fully-coherent X-ray pulses at 100 GW power level. With the radiation beam monochromatized down to the Fourier transform limit, a variety of very different techniques leading to further improvements of the LCLS performance become feasible. In particular, we describe an efficient way for obtaining full polarization control at the LCLS hard X-ray FEL. We also propose to exploit crystals in the Bragg reflection geometry as movable deflectors for the LCLS X-ray transport systems. The hard X-ray beam can be deflected of an angle of order of a radian without perturbations. The monochromatization of the output radiation constitutes the key for reaching such result. Finally, we describe a newoptical pump - hard X-ray probe technique which will allow time-resolved studies at the LCLS baseline on the femtosecond time scale. The principle of operation of the proposed scheme is essentially based on the use of the time jitter between pump and probe pulses. This eliminates the need for timing XFELs to high-power conventional lasers with femtosecond accuracy. (orig.)

  2. Sustained attention performance during sleep deprivation associates with instability in behavior and physiologic measures at baseline.

    Science.gov (United States)

    Chua, Eric Chern-Pin; Yeo, Sing-Chen; Lee, Ivan Tian-Guang; Tan, Luuan-Chin; Lau, Pauline; Cai, Shiwei; Zhang, Xiaodong; Puvanendran, Kathiravelu; Gooley, Joshua J

    2014-01-01

    To identify baseline behavioral and physiologic markers that associate with individual differences in sustained attention during sleep deprivation. In a retrospective study, ocular, electrocardiogram, and electroencephalogram (EEG) measures were compared in subjects who were characterized as resilient (n = 15) or vulnerable (n = 15) to the effects of total sleep deprivation on sustained attention. Chronobiology and Sleep Laboratory, Duke-NUS Graduate Medical School Singapore. Healthy volunteers aged 22-32 years from the general population. Subjects were kept awake for at least 26 hours under constant environmental conditions. Every 2 hours, sustained attention was assessed using a 10-minute psychomotor vigilance task (PVT). During baseline sleep and recovery sleep, EEG slow wave activity was similar in resilient versus vulnerable subjects, suggesting that individual differences in vulnerability to sleep loss were not related to differences in homeostatic sleep regulation. Rather, irrespective of time elapsed since wake, subjects who were vulnerable to sleep deprivation exhibited slower and more variable PVT response times, lower and more variable heart rate, and higher and more variable EEG spectral power in the theta frequency band (6.0-7.5 Hz). Performance decrements in sustained attention during sleep deprivation associate with instability in behavioral and physiologic measures at baseline. Small individual differences in sustained attention that are present at baseline are amplified during prolonged wakefulness, thus contributing to large between-subjects differences in performance and sleepiness.

  3. Esophageal acid exposure decreases intraluminal baseline impedance levels

    NARCIS (Netherlands)

    Kessing, Boudewijn F.; Bredenoord, Albert J.; Weijenborg, Pim W.; Hemmink, Gerrit J. M.; Loots, Clara M.; Smout, A. J. P. M.

    2011-01-01

    Intraluminal baseline impedance levels are determined by the conductivity of the esophageal wall and can be decreased in gastroesophageal reflux disease (GERD) patients. The aim of this study was to investigate the baseline impedance in GERD patients, on and off proton pump inhibitor (PPI), and in

  4. Measuring cognitive change with ImPACT: the aggregate baseline approach.

    Science.gov (United States)

    Bruce, Jared M; Echemendia, Ruben J; Meeuwisse, Willem; Hutchison, Michael G; Aubry, Mark; Comper, Paul

    2017-11-01

    The Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) is commonly used to assess baseline and post-injury cognition among athletes in North America. Despite this, several studies have questioned the reliability of ImPACT when given at intervals employed in clinical practice. Poor test-retest reliability reduces test sensitivity to cognitive decline, increasing the likelihood that concussed athletes will be returned to play prematurely. We recently showed that the reliability of ImPACT can be increased when using a new composite structure and the aggregate of two baselines to predict subsequent performance. The purpose of the present study was to confirm our previous findings and determine whether the addition of a third baseline would further increase the test-retest reliability of ImPACT. Data from 97 English speaking professional hockey players who had received at least 4 ImPACT baseline evaluations were extracted from a National Hockey League Concussion Program database. Linear regression was used to determine whether each of the first three testing sessions accounted for unique variance in the fourth testing session. Results confirmed that the aggregate baseline approach improves the psychometric properties of ImPACT, with most indices demonstrating adequate or better test-retest reliability for clinical use. The aggregate baseline approach provides a modest clinical benefit when recent baselines are available - and a more substantial benefit when compared to approaches that obtain baseline measures only once during the course of a multi-year playing career. Pending confirmation in diverse samples, neuropsychologists are encouraged to use the aggregate baseline approach to best quantify cognitive change following sports concussion.

  5. Study on the calibration and optimization of double theodolites baseline

    Science.gov (United States)

    Ma, Jing-yi; Ni, Jin-ping; Wu, Zhi-chao

    2018-01-01

    For the double theodolites measurement system baseline as the benchmark of the scale of the measurement system and affect the accuracy of the system, this paper puts forward a method for calibration and optimization of the double theodolites baseline. Using double theodolites to measure the known length of the reference ruler, and then reverse the baseline formula. Based on the error propagation law, the analyses show that the baseline error function is an important index to measure the accuracy of the system, and the reference ruler position, posture and so on have an impact on the baseline error. The optimization model is established and the baseline error function is used as the objective function, and optimizes the position and posture of the reference ruler. The simulation results show that the height of the reference ruler has no effect on the baseline error; the posture is not uniform; when the reference ruler is placed at x=500mm and y=1000mm in the measurement space, the baseline error is the smallest. The experimental results show that the experimental results are consistent with the theoretical analyses in the measurement space. In this paper, based on the study of the placement of the reference ruler, for improving the accuracy of the double theodolites measurement system has a reference value.

  6. Baseline factors that influence ASAS 20 response in patients with ankylosing spondylitis treated with etanercept.

    Science.gov (United States)

    Davis, John C; Van der Heijde, Désirée M F M; Dougados, Maxime; Braun, Jurgen; Cush, John J; Clegg, Daniel O; Inman, Robert D; de Vries, Todd; Tsuji, Wayne H

    2005-09-01

    To examine the baseline demographic and disease characteristics that might influence improvement as measured by the Assessment in Ankylosing Spondylitis Response Criteria (ASAS 20) in patients with ankylosing spondylitis (AS). A multicenter Phase 3 study was performed to compare the safety and efficacy of 24 weeks of etanercept 25 mg subcutaneous injection twice weekly (n = 138) and placebo (n = 139) in patients with AS. The ASAS 20 was measured at multiple time points. Using a significance level of 0.05, a repeated measures logistic regression model was used to determine which baseline factors influenced response in the etanercept-treated patients during the 24-week double blind portion of the trial. The following baseline factors were used in the model: demographic and disease severity variables, concomitant medications, extra-articular manifestations, and HLA-B27 status. The predictive capability of the model was then tested on the patients receiving placebo after they had received open-label etanercept treatment. Baseline factors that were significant predictors of an ASAS 20 response in etanercept-treated patients were C-reactive protein (CRP), back pain score, and Bath Ankylosing Spondylitis Functional Index (BASFI) score. Although clinical response to etanercept was seen at all levels of baseline disease activity, responses were consistently more likely with higher CRP levels or back pain scores and less likely with increased BASFI scores at baseline. Higher CRP values and back pain scores and lower BASFI scores at baseline were significant predictors of a higher ASAS 20 response in patients with AS receiving etanercept but predictive value was of insufficient magnitude to determine treatment in individual patients.

  7. In-Space Manufacturing Baseline Property Development

    Science.gov (United States)

    Stockman, Tom; Schneider, Judith; Prater, Tracie; Bean, Quincy; Werkheiser, Nicki

    2016-01-01

    The In-Space Manufacturing (ISM) project at NASA Marshall Space Flight Center currently operates a 3D FDM (fused deposition modeling) printer onboard the International Space Station. In order to enable utilization of this capability by designer, the project needs to establish characteristic material properties for materials produced using the process. This is difficult for additive manufacturing since standards and specifications do not yet exist for these technologies. Due to availability of crew time, there are limitations to the sample size which in turn limits the application of the traditional design allowables approaches to develop a materials property database for designers. In this study, various approaches to development of material databases were evaluated for use by designers of space systems who wish to leverage in-space manufacturing capabilities. This study focuses on alternative statistical techniques for baseline property development to support in-space manufacturing.

  8. Association between baseline impedance values and response proton pump inhibitors in patients with heartburn.

    Science.gov (United States)

    de Bortoli, Nicola; Martinucci, Irene; Savarino, Edoardo; Tutuian, Radu; Frazzoni, Marzio; Piaggi, Paolo; Bertani, Lorenzo; Furnari, Manuele; Franchi, Riccardo; Russo, Salvatore; Bellini, Massimo; Savarino, Vincenzo; Marchi, Santino

    2015-06-01

    Esophageal impedance measurements have been proposed to indicate the status of the esophageal mucosa, and might be used to study the roles of the impaired mucosal integrity and increased acid sensitivity in patients with heartburn. We compared baseline impedance levels among patients with heartburn who did and did not respond to proton pump inhibitor (PPI) therapy, along with the pathophysiological characteristics of functional heartburn (FH). In a case-control study, we collected data from January to December 2013 on patients with heartburn and normal findings from endoscopy who were not receiving PPI therapy and underwent impedance pH testing at hospitals in Italy. Patients with negative test results were placed on an 8-week course of PPI therapy (84 patients received esomeprazole and 36 patients received pantoprazole). Patients with more than 50% symptom improvement were classified as FH/PPI responders and patients with less than 50% symptom improvement were classified as FH/PPI nonresponders. Patients with hypersensitive esophagus and healthy volunteers served as controls. In all patients and controls, we measured acid exposure time, number of reflux events, baseline impedance, and swallow-induced peristaltic wave indices. FH/PPI responders had higher acid exposure times, numbers of reflux events, and acid refluxes compared with FH/PPI nonresponders (P < .05). Patients with hypersensitive esophagus had mean acid exposure times and numbers of reflux events similar to those of FH/PPI responders. Baseline impedance levels were lower in FH/PPI responders and patients with hypersensitive esophagus, compared with FH/PPI nonresponders and healthy volunteers (P < .001). Swallow-induced peristaltic wave indices were similar between FH/PPI responders and patients with hypersensitive esophagus. Patients with FH who respond to PPI therapy have impedance pH features similar to those of patients with hypersensitive esophagus. Baseline impedance measurements might allow for

  9. Methylphenidate during early consolidation affects long-term associative memory retrieval depending on baseline catecholamines.

    Science.gov (United States)

    Wagner, Isabella C; van Buuren, Mariët; Bovy, Leonore; Morris, Richard G; Fernández, Guillén

    2017-02-01

    Synaptic memory consolidation is thought to rely on catecholaminergic signaling. Eventually, it is followed by systems consolidation, which embeds memories in a neocortical network. Although this sequence was demonstrated in rodents, it is unclear how catecholamines affect memory consolidation in humans. Here, we tested the effects of catecholaminergic modulation on synaptic and subsequent systems consolidation. We expected enhanced memory performance and increased neocortical engagement during delayed retrieval. Additionally, we tested if this effect was modulated by individual differences in a cognitive proxy measure of baseline catecholamine synthesis capacity. Fifty-three healthy males underwent a between-subjects, double-blind, placebo-controlled procedure across 2 days. On day 1, subjects studied and retrieved object-location associations and received 20 mg of methylphenidate or placebo. Drug intake was timed so that methylphenidate was expected to affect early consolidation but not encoding or retrieval. Memory was tested again while subjects were scanned three days later. Methylphenidate did not facilitate memory performance, and there was no significant group difference in activation during delayed retrieval. However, memory representations differed between groups depending on baseline catecholamines. The placebo group showed increased activation in occipito-temporal regions but decreased connectivity with the hippocampus, associated with lower baseline catecholamine synthesis capacity. The methylphenidate group showed stronger activation in the postcentral gyrus, associated with higher baseline catecholamine synthesis capacity. Altogether, methylphenidate during early consolidation did not foster long-term memory performance, but it affected retrieval-related neural processes depending on individual levels of baseline catecholamines.

  10. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation.

    Science.gov (United States)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A; Thieden, Elisabeth; Wulf, Hans C

    2010-02-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol was measured at baseline. The increase in 25(OH)D level after UVB exposure was negatively correlated with baseline 25(OH)D level (Ppigmentation. In addition, we paired a dark-skinned group with a fair-skinned group according to baseline 25(OH)D levels and found no differences in 25(OH)D increase after identical UVB exposure.

  11. A Fully Customized Baseline Removal Framework for Spectroscopic Applications.

    Science.gov (United States)

    Giguere, Stephen; Boucher, Thomas; Carey, C J; Mahadevan, Sridhar; Dyar, M Darby

    2017-07-01

    The task of proper baseline or continuum removal is common to nearly all types of spectroscopy. Its goal is to remove any portion of a signal that is irrelevant to features of interest while preserving any predictive information. Despite the importance of baseline removal, median or guessed default parameters are commonly employed, often using commercially available software supplied with instruments. Several published baseline removal algorithms have been shown to be useful for particular spectroscopic applications but their generalizability is ambiguous. The new Custom Baseline Removal (Custom BLR) method presented here generalizes the problem of baseline removal by combining operations from previously proposed methods to synthesize new correction algorithms. It creates novel methods for each technique, application, and training set, discovering new algorithms that maximize the predictive accuracy of the resulting spectroscopic models. In most cases, these learned methods either match or improve on the performance of the best alternative. Examples of these advantages are shown for three different scenarios: quantification of components in near-infrared spectra of corn and laser-induced breakdown spectroscopy data of rocks, and classification/matching of minerals using Raman spectroscopy. Software to implement this optimization is available from the authors. By removing subjectivity from this commonly encountered task, Custom BLR is a significant step toward completely automatic and general baseline removal in spectroscopic and other applications.

  12. Baseline effects on carbon footprints of biofuels: The case of wood

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Eric, E-mail: johnsonatlantic@gmail.com [Atlantic Consulting, 8136 Gattikon (Switzerland); Tschudi, Daniel [ETH, Berghaldenstrasse 46, 8800 Thalwil (Switzerland)

    2012-11-15

    As biofuel usage has boomed over the past decade, so has research and regulatory interest in its carbon accounting. This paper examines one aspect of that carbon accounting: the baseline, i.e. the reference case against which other conditions or changes can be compared. A literature search and analysis identified four baseline types: no baseline; reference point; marginal fossil fuel; and biomass opportunity cost. The fourth one, biomass opportunity cost, is defined in more detail, because this is not done elsewhere in the literature. The four baselines are then applied to the carbon footprint of a wood-fired power plant. The footprint of the resulting wood-fired electricity varies dramatically, according to the type of baseline. Baseline type is also found to be the footprint's most significant sensitivity. Other significant sensitivities are: efficiency of the power plant; the growth (or re-growth) rate of the forest that supplies the wood; and the residue fraction of the wood. Length of the policy horizon is also an important factor in determining the footprint. The paper concludes that because of their significance and variability, baseline choices should be made very explicit in biofuel carbon footprints. - Highlights: Black-Right-Pointing-Pointer Four baseline types for biofuel footprinting are identified. Black-Right-Pointing-Pointer One type, 'biomass opportunity cost', is defined mathematically and graphically. Black-Right-Pointing-Pointer Choice of baseline can dramatically affect the footprint result. Black-Right-Pointing-Pointer The 'no baseline' approach is not acceptable. Black-Right-Pointing-Pointer Choice between the other three baselines depends on the question being addressed.

  13. Automated baseline change detection phase I. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    The Automated Baseline Change Detection (ABCD) project is supported by the DOE Morgantown Energy Technology Center (METC) as part of its ER&WM cross-cutting technology program in robotics. Phase 1 of the Automated Baseline Change Detection project is summarized in this topical report. The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrel and on feature recognition in images. In support of this primary objective, there are secondary objectives to determine DOE operational inspection requirements and DOE system fielding requirements.

  14. Automated baseline change detection phase I. Final report

    International Nuclear Information System (INIS)

    1995-12-01

    The Automated Baseline Change Detection (ABCD) project is supported by the DOE Morgantown Energy Technology Center (METC) as part of its ER ampersand WM cross-cutting technology program in robotics. Phase 1 of the Automated Baseline Change Detection project is summarized in this topical report. The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrel and on feature recognition in images. In support of this primary objective, there are secondary objectives to determine DOE operational inspection requirements and DOE system fielding requirements

  15. Vegetation Parameter Extraction Using Dual Baseline Polarimetric SAR Interferometry Data

    Science.gov (United States)

    Zhang, H.; Wang, C.; Chen, X.; Tang, Y.

    2009-04-01

    For vegetation parameter inversion, the single baseline polarimetric SAR interferometry (POLinSAR) technique, such as the three-stage method and the ESPRIT algorithm, is limited by the observed data with the minimum ground to volume amplitude ration, which effects the estimation of the effective phase center for the vegetation canopy or the surface, and thus results in the underestimated vegetation height. In order to remove this effect of the single baseline inversion techniques in some extend, another baseline POLinSAR data is added on vegetation parameter estimation in this paper, and a dual baseline POLinSAR technique for the extraction of the vegetation parameter is investigated and improved to reduce the dynamic bias for the vegetation parameter estimation. Finally, the simulated data and real data are used to validate this dual baseline technique.

  16. Information architecture. Volume 2, Part 1: Baseline analysis summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The Department of Energy (DOE) Information Architecture, Volume 2, Baseline Analysis, is a collaborative and logical next-step effort in the processes required to produce a Departmentwide information architecture. The baseline analysis serves a diverse audience of program management and technical personnel and provides an organized way to examine the Department`s existing or de facto information architecture. A companion document to Volume 1, The Foundations, it furnishes the rationale for establishing a Departmentwide information architecture. This volume, consisting of the Baseline Analysis Summary (part 1), Baseline Analysis (part 2), and Reference Data (part 3), is of interest to readers who wish to understand how the Department`s current information architecture technologies are employed. The analysis identifies how and where current technologies support business areas, programs, sites, and corporate systems.

  17. Relationship between visual field progression and baseline refraction in primary open-angle glaucoma.

    Science.gov (United States)

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Umeda, Yuzo; Shiraga, Fumio

    2016-01-01

    To analyze the relationship between visual field (VF) progression and baseline refraction in Japanese patients with primary open-angle glaucoma (POAG) including normal-tension glaucoma. In this retrospective study, the subjects were patients with POAG who had undergone VF tests at least ten times with a Humphrey Field Analyzer (Swedish interactive thresholding algorithm standard, Central 30-2 program). VF progression was defined as a significantly negative value of mean deviation (MD) slope at the final VF test. Multivariate logistic regression models were applied to detect an association between MD slope deterioration and baseline refraction. A total of 156 eyes of 156 patients were included in this analysis. Significant deterioration of MD slope was observed in 70 eyes of 70 patients (44.9%), whereas no significant deterioration was evident in 86 eyes of 86 patients (55.1%). The eyes with VF progression had significantly higher baseline refraction compared to those without apparent VF progression (-1.9±3.8 diopter [D] vs -3.5±3.4 D, P=0.0048) (mean ± standard deviation). When subject eyes were classified into four groups by the level of baseline refraction applying spherical equivalent (SE): no myopia (SE > -1D), mild myopia (-1D ≥ SE > -3D), moderate myopia (-3D ≥ SE > -6D), and severe myopia (-6D ≥ SE), the Cochran-Armitage trend analysis showed a decreasing trend in the proportion of MD slope deterioration with increasing severity of myopia (P=0.0002). The multivariate analysis revealed that baseline refraction (P=0.0108, odds ratio [OR]: 1.13, 95% confidence interval [CI]: 1.03-1.25) and intraocular pressure reduction rate (P=0.0150, OR: 0.97, 95% CI: 0.94-0.99) had a significant association with MD slope deterioration. In the current analysis of Japanese patients with POAG, baseline refraction was a factor significantly associated with MD slope deterioration as well as intraocular pressure reduction rate. When baseline refraction was classified into

  18. Unintended cultivation, shifting baselines, and conflict between objectives for fisheries and conservation.

    Science.gov (United States)

    Brown, Christopher J; Trebilco, Rowan

    2014-06-01

    The effects of fisheries on marine ecosystems, and their capacity to drive shifts in ecosystem states, have been widely documented. Less well appreciated is that some commercially valuable species respond positively to fishing-induced ecosystem change and can become important fisheries resources in modified ecosystems. Thus, the ecological effects of one fishery can unintentionally increase the abundance and productivity of other fished species (i.e., cultivate). We reviewed examples of this effect in the peer-reviewed literature. We found 2 underlying ecosystem drivers of the effect: trophic release of prey species when predators are overfished and habitat change. Key ecological, social, and economic conditions required for one fishery to unintentionally cultivate another include strong top-down control of prey by predators, the value of the new fishery, and the capacity of fishers to adapt to a new fishery. These unintended cultivation effects imply strong trade-offs between short-term fishery success and conservation efforts to restore ecosystems toward baseline conditions because goals for fisheries and conservation may be incompatible. Conflicts are likely to be exacerbated if fisheries baselines shift relative to conservation baselines and there is investment in the new fishery. However, in the long-term, restoration toward ecosystem baselines may often benefit both fishery and conservation goals. Unintended cultivation can be identified and predicted using a combination of time-series data, dietary studies, models of food webs, and socioeconomic data. Identifying unintended cultivation is necessary for management to set compatible goals for fisheries and conservation. © 2014 Society for Conservation Biology.

  19. Survey of Models on Demand, Customer Base-Line and Demand Response and Their Relationships in the Power Market

    OpenAIRE

    Heshmati, Almas

    2012-01-01

    The increasing use of demand-side management as a tool to reliably meet electricity demand at peak time has stimulated interest among researchers, consumers and producer organizations, managers, regulators and policymakers, This research reviews the growing literature on models used to study demand, consumer baseline (CBL) and demand response in the electricity market. After characterizing the general demand models, it reviews consumer baseline based on which further study the demand response...

  20. A study of man made radioactivity baseline in dietary materials

    International Nuclear Information System (INIS)

    de la Paz, L.; Estacio, J.; Palattao, M.V.; Anden, A.

    1986-01-01

    This paper describes the radioactivity baseline from literature data coming from various countries where data are available. 1979-1985 were chosen as the baseline years for the following: milk (fresh and powdered), meat and meat products, cereals, fruits, coffee and tea, fish and vegetables. Pre- and post-Chernobyl baseline data are given. (ELC). 21 figs; 17 refs

  1. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Cryogenics Testbed Laboratory Flange Baseline Configuration

    Science.gov (United States)

    Acuna, Marie Lei Ysabel D.

    2013-01-01

    As an intern at Kennedy Space Center (KSC), I was involved in research for the Fluids and Propulsion Division of the NASA Engineering (NE) Directorate. I was immersed in the Integrated Ground Operations Demonstration Units (IGODU) project for the majority of my time at KSC, primarily with the Ground Operations Demonstration Unit Liquid Oxygen (GODU L02) branch of IGODU. This project was established to develop advancements in cryogenic systems as a part of KSC's Advanced Exploration Systems (AES) program. The vision of AES is to develop new approaches for human exploration, and operations in and beyond low Earth orbit. Advanced cryogenic systems are crucial to minimize the consumable losses of cryogenic propellants, develop higher performance launch vehicles, and decrease operations cost for future launch programs. During my internship, I conducted a flange torque tracking study that established a baseline configuration for the flanges in the Simulated Propellant Loading System (SPLS) at the KSC Cryogenics Test Laboratory (CTL) - the testing environment for GODU L02.

  3. Baseline effects on carbon footprints of biofuels: The case of wood

    International Nuclear Information System (INIS)

    Johnson, Eric; Tschudi, Daniel

    2012-01-01

    As biofuel usage has boomed over the past decade, so has research and regulatory interest in its carbon accounting. This paper examines one aspect of that carbon accounting: the baseline, i.e. the reference case against which other conditions or changes can be compared. A literature search and analysis identified four baseline types: no baseline; reference point; marginal fossil fuel; and biomass opportunity cost. The fourth one, biomass opportunity cost, is defined in more detail, because this is not done elsewhere in the literature. The four baselines are then applied to the carbon footprint of a wood-fired power plant. The footprint of the resulting wood-fired electricity varies dramatically, according to the type of baseline. Baseline type is also found to be the footprint's most significant sensitivity. Other significant sensitivities are: efficiency of the power plant; the growth (or re-growth) rate of the forest that supplies the wood; and the residue fraction of the wood. Length of the policy horizon is also an important factor in determining the footprint. The paper concludes that because of their significance and variability, baseline choices should be made very explicit in biofuel carbon footprints. - Highlights: ► Four baseline types for biofuel footprinting are identified. ► One type, ‘biomass opportunity cost’, is defined mathematically and graphically. ► Choice of baseline can dramatically affect the footprint result. ► The ‘no baseline’ approach is not acceptable. ► Choice between the other three baselines depends on the question being addressed.

  4. Esophageal baseline impedance levels in patients with pathophysiological characteristics of functional heartburn.

    Science.gov (United States)

    Martinucci, I; de Bortoli, N; Savarino, E; Piaggi, P; Bellini, M; Antonelli, A; Savarino, V; Frazzoni, M; Marchi, S

    2014-04-01

    Recently, it has been suggested that low esophageal basal impedance may reflect impaired mucosal integrity and increased acid sensitivity. We aimed to compare baseline impedance levels in patients with heartburn and pathophysiological characteristics related to functional heartburn (FH) divided into two groups on the basis of symptom relief after proton pump inhibitors (PPIs). Patients with heartburn and negative endoscopy were treated with esomeprazole or pantoprazole 40 mg daily for 8 weeks. According to MII-pH (off therapy) analysis, patients with normal acid exposure time (AET), normal reflux number, and lack of association between symptoms and refluxes were selected; of whom 30 patients with a symptom relief higher than 50% after PPIs composed Group A, and 30 patients, matched for sex and age, without symptom relief composed Group B. A group of 20 healthy volunteers (HVs) was enrolled. For each patient and HV, we evaluated the baseline impedance levels at channel 3, during the overnight rest, at three different times. Group A (vs Group B) showed an increase in the following parameters: mean AET (1.4 ± 0.8% vs 0.5 ± 0.6%), mean reflux number (30.4 ± 8.7 vs 24 ± 6.9), proximal reflux number (11.1 ± 5.2 vs 8.2 ± 3.6), acid reflux number (17.9 ± 6.1 vs 10.7 ± 6.9). Baseline impedance levels were lower in Group A than in Group B and in HVs (p heartburn and normal AET could achieve a better understanding of pathophysiology in reflux disease patients, and could improve the distinction between FH and hypersensitive esophagus. © 2014 John Wiley & Sons Ltd.

  5. Long baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Gallagher, H.

    2006-01-01

    In this paper I will review briefly the experimental results which established the existence of neutrino mixing, the current generation of long baseline accelerator experiments, and the prospects for the future. In particular I will focus on the recent analysis of the MINOS experiment. (author)

  6. Baseline composition of solar energetic particles

    International Nuclear Information System (INIS)

    Meyer, J.

    1985-01-01

    We analyze all existing spacecraft observations of the highly variable heavy element composition of solar energetic particles (SEP) during non- 3 He-rich events. All data show the imprint of an ever-present basic composition pattern (dubbed ''mass-unbiased baseline'' SEP composition) that differs from the photospheric composition by a simple bias related to first ionization potential (FIP). In each particular observation, this mass-unbiased baseline composition is being distorted by an additional bias, which is always a monotonic function of mass (or Z). This latter bias varies in amplitude and even sign from observation to observation. To first order, it seems related to differences in the A/Z* ratio between elements (Z* = mean effective charge)

  7. Magical properties of a 2540 km baseline superbeam experiment

    International Nuclear Information System (INIS)

    Raut, Sushant K.; Singh, Ravi Shanker; Uma Sankar, S.

    2011-01-01

    Lack of any information on the CP violating phase δ CP weakens our ability to determine neutrino mass hierarchy. Magic baseline of 7500 km was proposed to overcome this problem. However, to obtain large enough fluxes, at this very long baseline, one needs new techniques of generating high intensity neutrino beams. In this Letter, we highlight the magical properties of a 2540 km baseline. At such a baseline, using a narrow band neutrino superbeam whose no oscillation event rate peaks around the energy 3.5 GeV, we can determine neutrino mass hierarchy independently of the CP phase. For sin 2 2θ 13 ≥0.05, a very modest exposure of 10 Kiloton-years is sufficient to determine the hierarchy. For 0.02≤sin 2 2θ 13 ≤0.05, an exposure of about 100 Kiloton-years is needed.

  8. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation

    DEFF Research Database (Denmark)

    Bogh, Morten K B; Schmedes, Anne; Philipsen, Peter A

    2010-01-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total...... cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used...... to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol...

  9. Re-creating missing population baselines for Pacific reef sharks.

    Science.gov (United States)

    Nadon, Marc O; Baum, Julia K; Williams, Ivor D; McPherson, Jana M; Zgliczynski, Brian J; Richards, Benjamin L; Schroeder, Robert E; Brainard, Russell E

    2012-06-01

    Sharks and other large predators are scarce on most coral reefs, but studies of their historical ecology provide qualitative evidence that predators were once numerous in these ecosystems. Quantifying density of sharks in the absence of humans (baseline) is, however, hindered by a paucity of pertinent time-series data. Recently researchers have used underwater visual surveys, primarily of limited spatial extent or nonstandard design, to infer negative associations between reef shark abundance and human populations. We analyzed data from 1607 towed-diver surveys (>1 ha transects surveyed by observers towed behind a boat) conducted at 46 reefs in the central-western Pacific Ocean, reefs that included some of the world's most pristine coral reefs. Estimates of shark density from towed-diver surveys were substantially lower (sharks observed in towed-diver surveys and human population in models that accounted for the influence of oceanic primary productivity, sea surface temperature, reef area, and reef physical complexity. We used these models to estimate the density of sharks in the absence of humans. Densities of gray reef sharks (Carcharhinus amblyrhynchos), whitetip reef sharks (Triaenodon obesus), and the group "all reef sharks" increased substantially as human population decreased and as primary productivity and minimum sea surface temperature (or reef area, which was highly correlated with temperature) increased. Simulated baseline densities of reef sharks under the absence of humans were 1.1-2.4/ha for the main Hawaiian Islands, 1.2-2.4/ha for inhabited islands of American Samoa, and 0.9-2.1/ha for inhabited islands in the Mariana Archipelago, which suggests that density of reef sharks has declined to 3-10% of baseline levels in these areas. ©2012 Society for Conservation Biology No claim to original US government works.

  10. DGEMP-OE (2008) Energy Baseline Scenario. Synthesis report

    International Nuclear Information System (INIS)

    2008-01-01

    A 'Business as usual' or 'Baseline' scenario of energy trends to 2020-2030 is produced by France every four years, as requested by the International Energy Agency in order to update the global scenarios published in its World Energy Outlook. Since the most recent scenario of this type was drawn up in 2003-2004, the time has come to renew the effort for the IEA's next in-depth review of French energy policy. Specifically, the DGEMP seeks to predict the future of France's energy situation assuming that no policies or new measures are taken affecting (i.e. improving or deteriorating) the situation other than those already in place or adopted as of 1 January 2008 (in other words, before measures such as those stemming from the Grenelle Environment Forum). On the other hand, it is assumed that change in the energy system is guided by 'conventional wisdom' according to which political options and behaviours by economic units are expected to be 'reasonable'. As a result, even should its projections prove inappropriate, this cannot be considered a 'worst-case' scenario. Indeed, beyond the IEA, this scenario can be used to establish an MEA (Multilateral Environment Agreement) scenario (based on existing measures) for national communications submitted under the U.N. Climate Convention. The scenarios by the 'Energy' Commission, part of the Centre d'Analyse Strategique (CAS), could have been used, particularly since the consultant who worked with the CAS to develop its scenarios was also commissioned by the DGEMP. However, several considerations argued in favour of proceeding separately: - The CAS scenarios drew on the DGEMP's 2004 baseline scenario, even though certain parameters were updated (in particular energy prices). - Moreover, the concept underpinning the DGEMP baseline scenario is that it should to every extent possible remain constant over time to secure continued consensus on this 'reference' at national level. - Finally, the MEDEE energy demand model applied in

  11. Baseline Assessment of Petroleum Contamination and Soil Properties at Contaminated Sites in Utqiagvik, Alaska

    Science.gov (United States)

    2017-08-01

    microbial community, including high bacterial numbers in these soils. The results from this baseline study indicate that stimulating biodegradation...CEERD-RR), ERDC- CRREL. At the time of publication, Dr. Justin Berman was Chief, CEERD- RRN; CDR J. D. Horne, USN (Ret), was Chief, CEERD-RR; and Dr...of the fractions of petroleum hydrocarbons and microbial activity in ERDC/CRREL TR-17-13 3 situ to reveal the status of each site at the time of

  12. Baseline metal concentrations in Paramoera walkeri from East Antarctica

    International Nuclear Information System (INIS)

    Palmer, Anne S. . E-mail Anne.Palmer@utas.edu.au; Snape, Ian; Stark, Jonathan S.; Johnstone, Glenn J.; Townsend, Ashley T.

    2006-01-01

    Remediation of the Thala Valley waste disposal site near Casey Station, East Antarctica was conducted in the austral summer of 2003/2004. Biomonitoring of the adjacent marine environment was undertaken using the gammaridean amphipod Paramoera walkeri as a sentinel species [Stark, J.S., Johnstone, G.J., Palmer, A.S., Snape, I., Larner, B.L., Riddle, M.J., in press, doi:10.1016/j.marpolbul.2006.05.020. Monitoring the remediation of a near shore waste disposal site in Antarctica using the amphipod Paramoera walkeri and diffusive gradients in thin films (DGTs). Marine Pollution Bulletin and references therein]. Determination of uptake of metals and hypothesis testing for differences that could be attributed to contamination required the establishment of baseline metal concentrations in P. walkeri. Baseline metal concentrations from two reference locations in the Windmill Islands are presented here. P. walkeri was a found to be a sensitive bioaccumulating organism that recorded spatial and temporal variability at the reference sites. Measurement of metals in P. walkeri required the development of a simple digestion procedure that used concentrated nitric acid. For the first time, rare earth metals were determined with additional clean procedures required to measure ultra low concentrations using magnetic sector ICP-MS. Certified and in-house reference materials were employed to ensure method reliability

  13. Wind power projects in the CDM: Methodologies and tools for baselines, carbon financing and sustainability analysis

    International Nuclear Information System (INIS)

    Ringius, L.; Grohnheit, P.E.; Nielsen, L.H.; Olivier, A.L.; Painuly, J.; Villavicencio, A.

    2002-12-01

    profile of Zafarana, the emission rates estimated by runs with 1 hour time-steps of the simulation tool ES3 range from 0.590 tCO 2 /MWh to 0.610 tCO 2 /MWh. These results come very close to estimates based on two different interpretations of standardized baseline options above. (au)

  14. Probing neutrino oscillations jointly in long and very long baseline experiments

    International Nuclear Information System (INIS)

    Wang, Y.F.; Whisnant, K.; Young Binglin; Xiong Zhaohua; Yang Jinmin

    2002-01-01

    We examine the prospects of making a joint analysis of neutrino oscillations at two baselines with neutrino superbeams. Assuming narrow band superbeams and a 100 kiloton water Cherenkov calorimeter, we calculate the event rates and sensitivities to the matter effect, the signs of the neutrino mass differences, the CP phase, and the mixing angle θ 13 . Taking into account all possible experimental errors under general consideration, we explore the optimum cases of a narrow band beam to measure the matter effect and the CP violation effect at all baselines up to 3000 km. We then focus on two specific baselines, a long baseline of 300 km and a very long baseline of 2100 km, and analyze their joint capabilities. We find that the joint analysis can offer extra leverage to resolve some of the ambiguities that are associated with the measurement at a single baseline

  15. A baseline-free procedure for transformation models under interval censorship.

    Science.gov (United States)

    Gu, Ming Gao; Sun, Liuquan; Zuo, Guoxin

    2005-12-01

    An important property of Cox regression model is that the estimation of regression parameters using the partial likelihood procedure does not depend on its baseline survival function. We call such a procedure baseline-free. Using marginal likelihood, we show that an baseline-free procedure can be derived for a class of general transformation models under interval censoring framework. The baseline-free procedure results a simplified and stable computation algorithm for some complicated and important semiparametric models, such as frailty models and heteroscedastic hazard/rank regression models, where the estimation procedures so far available involve estimation of the infinite dimensional baseline function. A detailed computational algorithm using Markov Chain Monte Carlo stochastic approximation is presented. The proposed procedure is demonstrated through extensive simulation studies, showing the validity of asymptotic consistency and normality. We also illustrate the procedure with a real data set from a study of breast cancer. A heuristic argument showing that the score function is a mean zero martingale is provided.

  16. Baseline cerebral oximetry values depend on non-modifiable patient characteristics.

    Science.gov (United States)

    Valencia, Lucía; Rodríguez-Pérez, Aurelio; Ojeda, Nazario; Santana, Romen Yone; Morales, Laura; Padrón, Oto

    2015-12-01

    The aim of the present study was to evaluate baseline regional cerebral oxygen saturation (rSO2) values and identify factors influencing preoperative rSO2 in elective minor surgery. Observational analysis post-hoc. Observational post-hoc analysis of data for the patient sample (n=50) of a previously conducted clinical trial in patients undergoing tumourectomy for breast cancer or inguinal hernia repair. Exclusion criteria included pre-existing cerebrovascular diseases, anaemia, baseline pulse oximetry values were recorded while the patient breathed room air, using the INVOS 5100C monitor™ (Covidien, Dublin, Ireland). Thirty-seven women (72%) and 13 men (28%) 48 ± 13 years of age were enrolled in this study. Baseline rSO2 was 62.01 ± 10.38%. Baseline rSO2 was significantly different between men (67.6 ± 11.2%) and women (60 ± 9.4%), (P=0.023). There were also differences between baseline rSO2 and ASA physical status (ASA I: 67.6 ± 10.7%, ASA II: 61.6 ± 8.4%, ASA III: 55.8 ± 13.9%, P=0.045). Baseline rSO2 had a positive correlation with body weight (r=0.347, P=0.014) and height (r=0.345, P=0.014). We also found significant differences in baseline rSO2 among patients with and without chronic renal failure (P=0.005). No differences were found in any other studied variables. Non-modifiable patient characteristics (ASA physical status, sex, chronic renal failure, body weight and height) influence baseline rSO2. Copyright © 2015 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  17. Effects of Baseline Selection on Magnetocardiography: P-Q and T-P Intervals

    International Nuclear Information System (INIS)

    Lim, Hyun Kyoon; Kwon, Hyuk Chan; Kim, Tae En; Lee, Yong Ho; Kim, Jin Mok; Kim, In Seon; Kim, Ki Woong; Park, Yong Ki

    2007-01-01

    The baseline selection is the first and important step to analyze magnetocardiography (MCG) parameters. There are no difficulties to select the baseline between P- and Q-wave peak (P-Q interval) of MCG wave recorded from healthy subjects because the P-Q intervals of the healthy subjects do not much vary. However, patients with ischemic heart disease often show an unstable P-Q interval which does not seem to be appropriate for the baseline. In this case, T-P interval is alternatively recommended for the baseline. However, there has been no study on the difference made by the baseline selection. In this study, we studied the effect of the different baseline selection. MCG data were analyzed from twenty healthy subjects and twenty one patients whose baselines were alternatively selected in the T-P interval for their inappropriate P-Q interval. Paired T-test was used to compare two set of data. Fifteen parameters derived from the R-wave peak, the T-wave peak, and the period, T max/3 ∼ T max were compared for the different baseline selection. As a result, most parameters did not show significant differences (p>0.05) except few parameters. Therefore, there will be no significant differences if anyone of two intervals were selected for the MCG baseline. However, for the consistent analysis, P-Q interval is strongly recommended for the baseline correction.

  18. Correlation between hypersensitivity induced by esophageal acid infusion and the baseline impedance level in patients with suspected gastroesophageal reflux.

    Science.gov (United States)

    Seo, A Young; Shin, Cheol Min; Kim, Nayoung; Yoon, Hyuk; Park, Young Soo; Lee, Dong Ho

    2015-07-01

    To evaluate the relevance between the pH parameters and baseline impedance level or esophageal hypomotility in patients with suspected gastroesophageal reflux. The recordings of 51 patients with heartburn, acid regurgitation, globus or noncardiac chest pain were analyzed. Evaluation included a 24-h multichannel intraluminal impedance-pH test while on off-proton pump inhibitor therapy over 1 week, high-resolution manometry and Bernstein test. Mean baseline impedance level at the most distal portion of the impedance channel was assessed manually. Esophageal hypomotility was evaluated using transitional zone defect (TZD) and distal break (DB) length measurement. In the study subjects (n = 51), 6 had a DeMeester score of more than 14.7 and 14 had a positive symptom index. The Bernstein test was positive in ten patients. The baseline impedance level was inversely correlated with the acid exposure time % (r = -0.660, P reflux and weakly acid reflux time % measured by impedance monitoring showed a weak correlation with TZD + DB length (r = 0.327 and 0.324, P = 0.019 and 0.020, respectively). Although a positive Bernstein test has no relevance for the acid exposure time or acid-related symptoms as represented by the DeMeester score or symptom index, the baseline impedance level was significantly lower in patients with a positive Bernstein test than in those with a negative one (2,628.4 ± 862.7 vs. 1,752.2 ± 611.1 Ω, P = 0.004). A lower baseline impedance level is closely related to increased esophageal acid exposure. Hypersensitivity induced by esophageal acid infusion might be attributed to acid-induced mucosal changes of the esophagus.

  19. Elevating Baseline Activation Does Not Facilitate Reading of Unattended Words

    Science.gov (United States)

    Lien, Mei-Ching; Kouchi, Scott; Ruthruff, Eric; Lachter, Joel B.

    2009-01-01

    Previous studies have disagreed the extent to which people extract meaning from words presented outside the focus of spatial attention. The present study, examined a possible explanation for such discrepancies, inspired by attenuation theory: unattended words can be read more automatically when they have a high baseline level of activation (e.g., due to frequent repetition or due to being expected in a given context). We presented a brief prime word in lowercase, followed by a target word in uppercase. Participants indicated whether the target word belonged to a particular category (e.g., "sport"). When we drew attention to the prime word using a visual cue, the prime produced substantial priming effects on target responses (i.e., faster responses when the prime and target words were identical or from the same category than when they belonged to different categories). When prime words were not attended, however, they produced no priming effects. This finding replicated even when there were only 4 words, each repeated 160 times during the experiment. Even with a very high baseline level of activation, it appears that very little word processing is possible without spatial attention.

  20. 40 CFR 80.915 - How are the baseline toxics value and baseline toxics volume determined?

    Science.gov (United States)

    2010-07-01

    ... baseline toxics value if it can determine an applicable toxics value for every batch of gasoline produced... of gasoline batch i produced or imported between January 1, 1998 and December 31, 2000, inclusive. i = Individual batch of gasoline produced or imported between January 1, 1998 and December 31, 2000, inclusive. n...

  1. Shifted Baselines Reduce Willingness to Pay for Conservation

    Directory of Open Access Journals (Sweden)

    Loren McClenachan

    2018-02-01

    Full Text Available A loss of memory of past environmental degradation has resulted in shifted baselines, which may result in conservation and restoration goals that are less ambitious than if stakeholders had a full knowledge of ecosystem potential. However, the link between perception of baseline states and support for conservation planning has not been tested empirically. Here, we investigate how perceptions of change in coral reef ecosystems affect stakeholders' willingness to pay (WTP for the establishment of protected areas. Coral reefs are experiencing rapid, global change that is observable by the public, and therefore provide an ideal ecosystem to test links between beliefs about baseline states and willingness to support conservation. Our survey respondents perceived change to coral reef communities across six variables: coral abundance, fish abundance, fish diversity, fish size, sedimentation, and water pollution. Respondants who accurately perceived declines in reef health had significantly higher WTP for protected areas (US $256.80 vs. $102.50 per year, suggesting that shifted baselines may reduce engagement with conservation efforts. If WTP translates to engagement, this suggests that goals for restoration and recovery are likely to be more ambitious if the public is aware of long term change. Therefore, communicating the scope and depth of environmental problems is essential in engaging the public in conservation.

  2. Baseline Projection Data Book: GRI baseline projection of U.S. Energy Supply and Demand to 2010. 1992 Edition. Volume 1 and Volume 2

    International Nuclear Information System (INIS)

    Holtberg, P.D.; Woods, T.J.; Lihn, M.L.; Koklauner, A.K.

    1992-01-01

    The 1992 Baseline Projection Data Book provides backup data in tabular form for the 1992 GRI Baseline Projection of U.S. Energy Supply and Demand to 2010. Summary tables and data for the residential, commercial, industrial, electric utility, and transportation sectors are presented in the volume

  3. Baseline for the cumulants of net-proton distributions at STAR

    International Nuclear Information System (INIS)

    Luo, Xiaofeng; Mohanty, Bedangadas; Xu, Nu

    2014-01-01

    We present a systematic comparison between the recently measured cumulants of the net-proton distributions by STAR for 0–5% central Au + Au collisions at √(s NN )=7.7–200 GeV and two kinds of possible baseline measure, the Poisson and Binomial baselines. These baseline measures are assuming that the proton and anti-proton distributions independently follow Poisson statistics or Binomial statistics. The higher order cumulant net-proton data are observed to deviate from all the baseline measures studied at 19.6 and 27 GeV. We also compare the net-proton with net-baryon fluctuations in UrQMD and AMPT model, and convert the net-proton fluctuations to net-baryon fluctuations in AMPT model by using a set of formula

  4. Parkinson’s Disease Severity at 3 Years Can Be Predicted from Non-Motor Symptoms at Baseline

    Directory of Open Access Journals (Sweden)

    Alba Ayala

    2017-10-01

    Full Text Available ObjectiveThe aim of this study is to present a predictive model of Parkinson’s disease (PD global severity, measured with the Clinical Impression of Severity Index for Parkinson’s Disease (CISI-PD.MethodsThis is an observational, longitudinal study with annual follow-up assessments over 3 years (four time points. A multilevel analysis and multiple imputation techniques were performed to generate a predictive model that estimates changes in the CISI-PD at 1, 2, and 3 years.ResultsThe clinical state of patients (CISI-PD significantly worsened in the 3-year follow-up. However, this change was of small magnitude (effect size: 0.44. The following baseline variables were significant predictors of the global severity change: baseline global severity of disease, levodopa equivalent dose, depression and anxiety symptoms, autonomic dysfunction, and cognitive state. The goodness-of-fit of the model was adequate, and the sensitive analysis showed that the data imputation method applied was suitable.ConclusionDisease progression depends more on the individual’s baseline characteristics than on the 3-year time period. Results may contribute to a better understanding of the evolution of PD including the non-motor manifestations of the disease.

  5. Conservation of forest birds: evidence of a shifting baseline in community structure.

    Science.gov (United States)

    Rittenhouse, Chadwick D; Pidgeon, Anna M; Albright, Thomas P; Culbert, Patrick D; Clayton, Murray K; Flather, Curtis H; Huang, Chengquan; Masek, Jeffrey G; Stewart, Susan I; Radeloff, Volker C

    2010-08-02

    Quantifying changes in forest bird diversity is an essential task for developing effective conservation actions. When subtle changes in diversity accumulate over time, annual comparisons may offer an incomplete perspective of changes in diversity. In this case, progressive change, the comparison of changes in diversity from a baseline condition, may offer greater insight because changes in diversity are assessed over longer periods of times. Our objectives were to determine how forest bird diversity has changed over time and whether those changes were associated with forest disturbance. We used North American Breeding Bird Survey data, a time series of Landsat images classified with respect to land cover change, and mixed-effects models to associate changes in forest bird community structure with forest disturbance, latitude, and longitude in the conterminous United States for the years 1985 to 2006. We document a significant divergence from the baseline structure for all birds of similar migratory habit and nest location, and all forest birds as a group from 1985 to 2006. Unexpectedly, decreases in progressive similarity resulted from small changes in richness (<1 species per route for the 22-year study period) and modest losses in abundance (-28.7 - -10.2 individuals per route) that varied by migratory habit and nest location. Forest disturbance increased progressive similarity for Neotropical migrants, permanent residents, ground nesting, and cavity nesting species. We also documented highest progressive similarity in the eastern United States. Contemporary forest bird community structure is changing rapidly over a relatively short period of time (e.g., approximately 22 years). Forest disturbance and forest regeneration are primary factors associated with contemporary forest bird community structure, longitude and latitude are secondary factors, and forest loss is a tertiary factor. Importantly, these findings suggest some regions of the United States may

  6. FED baseline engineering studies report

    Energy Technology Data Exchange (ETDEWEB)

    Sager, P.H.

    1983-04-01

    Studies were carried out on the FED Baseline to improve design definition, establish feasibility, and reduce cost. Emphasis was placed on cost reduction, but significant feasibility concerns existed in several areas, and better design definition was required to establish feasibility and provide a better basis for cost estimates. Design definition and feasibility studies included the development of a labyrinth shield ring concept to prevent radiation streaming between the torus spool and the TF coil cryostat. The labyrinth shield concept which was developed reduced radiation streaming sufficiently to permit contact maintenance of the inboard EF coils. Various concepts of preventing arcing between adjacent shield sectors were also explored. It was concluded that installation of copper straps with molybdenum thermal radiation shields would provide the most reliable means of preventing arcing. Other design studies included torus spool electrical/structural concepts, test module shielding, torus seismic response, poloidal conditions in the magnets, disruption characteristics, and eddy current effects. These additional studies had no significant impact on cost but did confirm the feasibility of the basic FED Baseline concept.

  7. FED baseline engineering studies report

    International Nuclear Information System (INIS)

    Sager, P.H.

    1983-04-01

    Studies were carried out on the FED Baseline to improve design definition, establish feasibility, and reduce cost. Emphasis was placed on cost reduction, but significant feasibility concerns existed in several areas, and better design definition was required to establish feasibility and provide a better basis for cost estimates. Design definition and feasibility studies included the development of a labyrinth shield ring concept to prevent radiation streaming between the torus spool and the TF coil cryostat. The labyrinth shield concept which was developed reduced radiation streaming sufficiently to permit contact maintenance of the inboard EF coils. Various concepts of preventing arcing between adjacent shield sectors were also explored. It was concluded that installation of copper straps with molybdenum thermal radiation shields would provide the most reliable means of preventing arcing. Other design studies included torus spool electrical/structural concepts, test module shielding, torus seismic response, poloidal conditions in the magnets, disruption characteristics, and eddy current effects. These additional studies had no significant impact on cost but did confirm the feasibility of the basic FED Baseline concept

  8. Baseline development, economic risk, and schedule risk: An integrated approach

    International Nuclear Information System (INIS)

    Tonkinson, J.A.

    1994-01-01

    The economic and schedule risks of Environmental Restoration (ER) projects are commonly analyzed toward the end of the baseline development process. Risk analysis is usually performed as the final element of the scheduling or estimating processes for the purpose of establishing cost and schedule contingency. However, there is an opportunity for earlier assessment of risks, during development of the technical scope and Work Breakdown Structure (WBS). Integrating the processes of risk management and baselining provides for early incorporation of feedback regarding schedule and cost risk into the proposed scope of work. Much of the information necessary to perform risk analysis becomes available during development of the technical baseline, as the scope of work and WBS are being defined. The analysis of risk can actually be initiated early on during development of the technical baseline and continue throughout development of the complete project baseline. Indeed, best business practices suggest that information crucial to the success of a project be analyzed and incorporated into project planning as soon as it is available and usable

  9. The long-period eccentric orbit of the particle accelerator HD 167971 revealed by long baseline interferometry

    NARCIS (Netherlands)

    De Becker, M.; Sana, H.; Absil, O.; Le Bouquin, J.-B.; Blomme, R.

    2012-01-01

    Using optical long baseline interferometry, we resolved for the first time the two wide components of HD 167971, a candidate hierarchical triple system known to efficiently accelerate particles. Our multi-epoch Very Large Telescope Interferometer observations provide direct evidence for a

  10. Performance Analysis for Airborne Interferometric SAR Affected by Flexible Baseline Oscillation

    Directory of Open Access Journals (Sweden)

    Liu Zhong-sheng

    2014-04-01

    Full Text Available The airborne interferometric SAR platform suffers from instability factors, such as air turbulence and mechanical vibrations during flight. Such factors cause the oscillation of the flexible baseline, which leads to significant degradation of the performance of the interferometric SAR system. This study is concerned with the baseline oscillation. First, the error of the slant range model under baseline oscillation conditions is formulated. Then, the SAR complex image signal and dual-channel correlation coefficient are modeled based on the first-order, second-order, and generic slant range error. Subsequently, the impact of the baseline oscillation on the imaging and interferometric performance of the SAR system is analyzed. Finally, simulations of the echo data are used to validate the theoretical analysis of the baseline oscillation in the airborne interferometric SAR.

  11. The Effect of Antenna Position Errors on Redundant-Baseline Calibration of HERA

    Science.gov (United States)

    Orosz, Naomi; Dillon, Joshua; Ewall-Wice, Aaron; Parsons, Aaron; HERA Collaboration

    2018-01-01

    HERA (the Hydrogen Epoch of Reionization Array) is a large, highly-redundant radio interferometer in South Africa currently being built out to 350 14-m dishes. Its mission is to probe large scale structure during and prior to the epoch of reionization using the 21 cm hyperfine transition of neutral hydrogen. The array is designed to be calibrated using redundant baselines of known lengths. However, the dishes can deviate from ideal positions, with errors on the order of a few centimeters. This potentially increases foreground contamination of the 21 cm power spectrum in the cleanest part of Fourier space. The calibration algorithm treats groups of baselines that should be redundant, but are not due to position errors, as if they actually are. Accurate, precise calibration is critical because the foreground signals are 100,000 times stronger than the reionization signal. We explain the origin of this effect and discuss weighting strategies to mitigate it.

  12. Influence of Baseline Psychological Health on Muscle Pain During Atorvastatin Treatment.

    Science.gov (United States)

    Zaleski, Amanda L; Taylor, Beth A; Pescatello, Linda S; Dornelas, Ellen A; White, Charles Michael; Thompson, Paul D

    3-hydroxy-3-methylglutaryl coenzyme A reductase reductase inhibitors (statins) are generally well tolerated, with statin-associated muscle symptoms (SAMS) the most common side effect (~10%) seen in statin users. However, studies and clinical observations indicate that many of the self-reported SAMS appear to be nonspecific (ie, potentially not attributable to statins). Mental health and well-being influence self-perception of pain, so we sought to assess the effect of baseline well-being and depression on the development of muscle pain with 6 months of atorvastatin 80 mg/d (ATORVA) or placebo in healthy, statin-naive adults. The Psychological General Well-being Index (n = 83) and Beck Depression Inventory (n = 55) questionnaires were administered at baseline in participants (aged 59.5 ± 1.2 years) from the effect of Statins on Skeletal Muscle Function and Performance (STOMP) trial (NCT00609063). Muscle pain (Short-Form McGill Pain Questionnaire [SF-MPQ]), pain that interferes with daily life (Brief Pain Inventory [BPI]), and pain severity (BPI) were then measured before, throughout, and after treatment. At baseline, there were no differences in well-being (Psychological General Well-being Index), depression (Beck Depression Inventory), or pain measures (SF-MPQ and BPI) (P values ≥ .05) between the placebo and ATORVA groups. Baseline well-being correlated negatively with baseline BPI pain severity (r = -0.290, P = .008). Baseline depression correlated with baseline pain (SF-MPQ; r = 0.314, P = .020). Baseline well-being and depression did not predict the change in pain severity or interference after 6 months among the total sample or between groups (P values ≥ .05). Baseline well-being and depression were not significant predictors of pain after 6 months of ATORVA (P values ≥ .05). Thus, they do not appear to increase the risk of SAMS in otherwise healthy adults.

  13. Baseline Report on HB2320

    Science.gov (United States)

    State Council of Higher Education for Virginia, 2015

    2015-01-01

    Staff provides this baseline report as a summary of its preliminary considerations and initial research in fulfillment of the requirements of HB2320 from the 2015 session of the General Assembly. Codified as § 23-7.4:7, this legislation compels the Education Secretary and the State Council of Higher Education for Virginia (SCHEV) Director, in…

  14. Analysis of factors affecting baseline SF-36 Mental Component Summary in Adult Spinal Deformity and its impact on surgical outcomes.

    Science.gov (United States)

    Mmopelwa, Tiro; Ayhan, Selim; Yuksel, Selcen; Nabiyev, Vugar; Niyazi, Asli; Pellise, Ferran; Alanay, Ahmet; Sanchez Perez Grueso, Francisco Javier; Kleinstuck, Frank; Obeid, Ibrahim; Acaroglu, Emre

    2018-03-01

    To identify the factors that affect SF-36 mental component summary (MCS) in patients with adult spinal deformity (ASD) at the time of presentation, and to analyse the effect of SF-36 MCS on clinical outcomes in surgically treated patients. Prospectively collected data from a multicentric ASD database was analysed for baseline parameters. Then, the same database for surgically treated patients with a minimum of 1-year follow-up was analysed to see the effect of baseline SF-36 MCS on treatment results. A clinically useful SF-36 MCS was determined by ROC Curve analysis. A total of 229 patients with the baseline parameters were analysed. A strong correlation between SF-36 MCS and SRS-22, ODI, gender, and diagnosis were found (p baseline SF-36 MCS (p baseline SF-36 MCS in an ASD population are other HRQOL parameters such as SRS-22 and ODI as well as the baseline thoracic kyphosis and gender. This study has also demonstrated that baseline SF-36 MCS does not necessarily have any effect on the treatment results by surgery as assessed by SRS-22 or ODI. Level III, prognostic study. Copyright © 2018 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  15. Esophageal intraluminal baseline impedance is associated with severity of acid reflux and epithelial structural abnormalities in patients with gastroesophageal reflux disease.

    Science.gov (United States)

    Zhong, Chanjuan; Duan, Liping; Wang, Kun; Xu, Zhijie; Ge, Ying; Yang, Changqing; Han, Yajing

    2013-05-01

    The esophageal intraluminal baseline impedance may be used to evaluate the status of mucosa integrity. Esophageal acid exposure decreases the baseline impedance. We aimed to compare baseline impedance in patients with various reflux events and with different acid-related parameters, and investigate the relationships between epithelial histopathologic abnormalities and baseline impedance. A total of 229 GERD patients and 34 controls underwent 24-h multichannel intraluminal impedance and pH monitoring (MII-pH monitoring), gastroendoscopy, and completed a GERD questionnaire (GerdQ). We quantified epithelial intercellular spaces (ICSs) and expression of tight junction (TJ) proteins by histologic techniques. Mean baseline values in reflux esophagitis (RE) (1752 ± 1018 Ω) and non-erosive reflux disease (NERD) (2640 ± 1143 Ω) were significantly lower than in controls (3360 ± 1258 Ω; p acid reflux group (2510 ± 1239 Ω) and mixed acid/weakly acidic reflux group (2393 ± 1009 Ω) were much lower than in controls (3360 ± 1258 Ω; p = 0.020 and p acid exposure time (AET) (r = -0.41, p acid reflux events and with longer AET have low baseline impedance. Baseline values are correlated with esophageal mucosal histopathologic changes such as dilated ICS and TJ alteration.

  16. U Plant Aggregate Area Management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document was prepared in support of an Aggregate Area Management Study of U Plant. It provides a technical baseline of the aggregate area and results from an environmental investigation that was undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC), which is currently the Waste Site and Facility Research Office, Natural Resources, Bechtel Hanford, Inc. (BHI). It is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. U Plant refers to the 221-U Process Canyon Building, a chemical separation facility constructed during World War II. It also includes the Uranium Oxide (UO 3 ) Plant constructed at the same time as 221-U as an adjunct to the original plutonium separation process but which, like 221-U, was converted for other missions. Waste sites are associated primarily with U Plant's 1952 through 1958 Uranium Metal Recovery Program mission and the U0 3 Plant's ongoing U0 3 mission. Waste sites include cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, a waste vault, and the lines and encasements that connect them. It also includes the U Pond and its feed ditches and an underground tank farm designed for high-level liquid wastes

  17. Baseline Architecture of ITER Control System

    Science.gov (United States)

    Wallander, A.; Di Maio, F.; Journeaux, J.-Y.; Klotz, W.-D.; Makijarvi, P.; Yonekawa, I.

    2011-08-01

    The control system of ITER consists of thousands of computers processing hundreds of thousands of signals. The control system, being the primary tool for operating the machine, shall integrate, control and coordinate all these computers and signals and allow a limited number of staff to operate the machine from a central location with minimum human intervention. The primary functions of the ITER control system are plant control, supervision and coordination, both during experimental pulses and 24/7 continuous operation. The former can be split in three phases; preparation of the experiment by defining all parameters; executing the experiment including distributed feed-back control and finally collecting, archiving, analyzing and presenting all data produced by the experiment. We define the control system as a set of hardware and software components with well defined characteristics. The architecture addresses the organization of these components and their relationship to each other. We distinguish between physical and functional architecture, where the former defines the physical connections and the latter the data flow between components. In this paper, we identify the ITER control system based on the plant breakdown structure. Then, the control system is partitioned into a workable set of bounded subsystems. This partition considers at the same time the completeness and the integration of the subsystems. The components making up subsystems are identified and defined, a naming convention is introduced and the physical networks defined. Special attention is given to timing and real-time communication for distributed control. Finally we discuss baseline technologies for implementing the proposed architecture based on analysis, market surveys, prototyping and benchmarking carried out during the last year.

  18. Changes in vitamin D supplement use and baseline plasma 25-hydroxyvitamin D concentration predict 5-y change in concentration in postmenopausal women.

    Science.gov (United States)

    Kluczynski, Melissa A; Wactawski-Wende, Jean; Platek, Mary E; DeNysschen, Carol A; Hovey, Kathleen M; Millen, Amy E

    2012-09-01

    Few studies have prospectively examined predictors of change in plasma concentrations of 25-hydroxyvitamin D [25(OH)D]. We sought to determine the predictors of 5-y change in 25(OH)D. Plasma 25(OH)D concentrations were assessed at baseline (1997-2000) and 5 y later (2002-2005) in 668 postmenopausal women enrolled in the Osteoporosis and Periodontal Disease Study. Baseline and changes in demographic, dietary, lifestyle, and health-related factors were tested as predictors of change in 25(OH)D concentrations by using multivariable linear regression. The mean 5-y change in 25(OH)D (mean ± SD) was 7.7 ± 0.7 nmol/L (P D concentrations and included baseline 25(OH)D, baseline and change in vitamin D supplementation and physical activity, change in season of blood draw, BMI, whole-body T score, and baseline hormone therapy use. Baseline 25(OH)D and change in vitamin D supplementation explained the most variation (25%) in 25(OH)D. Exploratory analyses showed a borderline significant interaction between tertiles of baseline 25(OH)D and change in vitamin D supplementation over time (P = 0.06). The greatest mean increase in 25(OH)D (22.9 ± 16.8 nmol/L), with adjustment for other statistically significant predictors, occurred in women whose baseline 25(OH)D concentration was ≤51.0 nmol/L (tertile 1) and who increased supplementation use over time. These results confirm the importance of supplementation in increasing 25(OH)D concentrations in aging women, even after other statistically significant predictors are controlled for. These data also suggest that this is especially true among aging women with inadequate 25(OH)D (e.g., <50 nmol/L).

  19. Baseline Optimization for the Measurement of CP Violation, Mass Hierarchy, and $\\theta_{23}$ Octant in a Long-Baseline Neutrino Oscillation Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bass, M. [Colorado State U.; Bishai, M. [Brookhaven; Cherdack, D. [Colorado State U.; Diwan, M. [Brookhaven; Djurcic, Z. [Argonne; Hernandez, J. [Houston U.; Lundberg, B. [Fermilab; Paolone, V. [Pittsburgh U.; Qian, X. [Brookhaven; Rameika, R. [Fermilab; Whitehead, L. [Houston U.; Wilson, R. J. [Colorado State U.; Worcester, E. [Brookhaven; Zeller, G. [Fermilab

    2015-03-19

    Next-generation long-baseline electron neutrino appearance experiments will seek to discover CP violation, determine the mass hierarchy and resolve the θ23 octant. In light of the recent precision measurements of θ13, we consider the sensitivity of these measurements in a study to determine the optimal baseline, including practical considerations regarding beam and detector performance. We conclude that a detector at a baseline of at least 1000 km in a wide-band muon neutrino beam is the optimal configuration.

  20. Should Studies of Diabetes Treatment Stratification Correct for Baseline HbA1c?

    Science.gov (United States)

    Jones, Angus G.; Lonergan, Mike; Henley, William E.; Pearson, Ewan R.; Hattersley, Andrew T.; Shields, Beverley M.

    2016-01-01

    Aims Baseline HbA1c is a major predictor of response to glucose lowering therapy and therefore a potential confounder in studies aiming to identify other predictors. However, baseline adjustment may introduce error if the association between baseline HbA1c and response is substantially due to measurement error and regression to the mean. We aimed to determine whether studies of predictors of response should adjust for baseline HbA1c. Methods We assessed the relationship between baseline HbA1c and glycaemic response in 257 participants treated with GLP-1R agonists and assessed whether it reflected measurement error and regression to the mean using duplicate ‘pre-baseline’ HbA1c measurements not included in the response variable. In this cohort and an additional 2659 participants treated with sulfonylureas we assessed the relationship between covariates associated with baseline HbA1c and treatment response with and without baseline adjustment, and with a bias correction using pre-baseline HbA1c to adjust for the effects of error in baseline HbA1c. Results Baseline HbA1c was a major predictor of response (R2 = 0.19,β = -0.44,pHbA1c were associated with response, however these associations were weak or absent after adjustment for baseline HbA1c. Bias correction did not substantially alter associations. Conclusions Adjustment for the baseline HbA1c measurement is a simple and effective way to reduce bias in studies of predictors of response to glucose lowering therapy. PMID:27050911

  1. Baseline series fragrance markers fail to predict contact allergy.

    Science.gov (United States)

    Mann, Jack; McFadden, John P; White, Jonathan M L; White, Ian R; Banerjee, Piu

    2014-05-01

    Negative patch test results with fragrance allergy markers in the European baseline series do not always predict a negative reaction to individual fragrance substances. To determine the frequencies of positive test reactions to the 26 fragrance substances for which labelling is mandatory in the EU, and how effectively reactions to fragrance markers in the baseline series predict positive reactions to the fragrance substances that are labelled. The records of 1951 eczema patients, routinely tested with the labelled fragrance substances and with an extended European baseline series in 2011 and 2012, were retrospectively reviewed. Two hundred and eighty-one (14.4%) (71.2% females) reacted to one or more allergens from the labelled-fragrance substance series and/or a fragrance marker from the European baseline series. The allergens that were positive with the greatest frequencies were cinnamyl alcohol (48; 2.46%), Evernia furfuracea (44; 2.26%), and isoeugenol (40; 2.05%). Of the 203 patients who reacted to any of the 26 fragrances in the labelled-fragrance substance series, only 117 (57.6%) also reacted to a fragrance marker in the baseline series. One hundred and seven (52.7%) reacted to either fragrance mix I or fragrance mix II, 28 (13.8%) reacted to Myroxylon pereirae, and 13 (6.4%) reacted to hydroxyisohexyl 3-cyclohexene carboxaldehyde. These findings confirm that the standard fragrance markers fail to identify patients with contact allergies to the 26 fragrances. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. A publication database for optical long baseline interferometry

    Science.gov (United States)

    Malbet, Fabien; Mella, Guillaume; Lawson, Peter; Taillifet, Esther; Lafrasse, Sylvain

    2010-07-01

    Optical long baseline interferometry is a technique that has generated almost 850 refereed papers to date. The targets span a large variety of objects from planetary systems to extragalactic studies and all branches of stellar physics. We have created a database hosted by the JMMC and connected to the Optical Long Baseline Interferometry Newsletter (OLBIN) web site using MySQL and a collection of XML or PHP scripts in order to store and classify these publications. Each entry is defined by its ADS bibcode, includes basic ADS informations and metadata. The metadata are specified by tags sorted in categories: interferometric facilities, instrumentation, wavelength of operation, spectral resolution, type of measurement, target type, and paper category, for example. The whole OLBIN publication list has been processed and we present how the database is organized and can be accessed. We use this tool to generate statistical plots of interest for the community in optical long baseline interferometry.

  3. Back-calculating baseline creatinine overestimates prevalence of acute kidney injury with poor sensitivity.

    Science.gov (United States)

    Kork, F; Balzer, F; Krannich, A; Bernardi, M H; Eltzschig, H K; Jankowski, J; Spies, C

    2017-03-01

    Acute kidney injury (AKI) is diagnosed by a 50% increase in creatinine. For patients without a baseline creatinine measurement, guidelines suggest estimating baseline creatinine by back-calculation. The aim of this study was to evaluate different glomerular filtration rate (GFR) equations and different GFR assumptions for back-calculating baseline creatinine as well as the effect on the diagnosis of AKI. The Modification of Diet in Renal Disease, the Chronic Kidney Disease Epidemiology (CKD-EPI) and the Mayo quadratic (MQ) equation were evaluated to estimate baseline creatinine, each under the assumption of either a fixed GFR of 75 mL min -1  1.73 m -2 or an age-adjusted GFR. Estimated baseline creatinine, diagnoses and severity stages of AKI based on estimated baseline creatinine were compared to measured baseline creatinine and corresponding diagnoses and severity stages of AKI. The data of 34 690 surgical patients were analysed. Estimating baseline creatinine overestimated baseline creatinine. Diagnosing AKI based on estimated baseline creatinine had only substantial agreement with AKI diagnoses based on measured baseline creatinine [Cohen's κ ranging from 0.66 (95% CI 0.65-0.68) to 0.77 (95% CI 0.76-0.79)] and overestimated AKI prevalence with fair sensitivity [ranging from 74.3% (95% CI 72.3-76.2) to 90.1% (95% CI 88.6-92.1)]. Staging AKI severity based on estimated baseline creatinine had moderate agreement with AKI severity based on measured baseline creatinine [Cohen's κ ranging from 0.43 (95% CI 0.42-0.44) to 0.53 (95% CI 0.51-0.55)]. Diagnosing AKI and staging AKI severity on the basis of estimated baseline creatinine in surgical patients is not feasible. Patients at risk for post-operative AKI should have a pre-operative creatinine measurement to adequately assess post-operative AKI. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  4. Solid Waste Program technical baseline description

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, A.B.

    1994-07-01

    The system engineering approach has been taken to describe the technical baseline under which the Solid Waste Program is currently operating. The document contains a mission analysis, function analysis, system definition, documentation requirements, facility and project bases, and uncertainties facing the program.

  5. Long-baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Crane, D.; Goodman, M.

    1994-01-01

    There is no unambiguous definition for long baseline neutrino oscillation experiments. The term is generally used for accelerator neutrino oscillation experiments which are sensitive to Δm 2 2 , and for which the detector is not on the accelerator site. The Snowmass N2L working group met to discuss the issues facing such experiments. The Fermilab Program Advisory Committee adopted several recommendations concerning the Fermilab neutrino program at their Aspen meeting immediately prior to the Snowmass Workshop. This heightened the attention for the proposals to use Fermilab for a long-baseline neutrino experiment at the workshop. The plan for a neutrino oscillation program at Brookhaven was also thoroughly discussed. Opportunities at CERN were considered, particularly the use of detectors at the Gran Sasso laboratory. The idea to build a neutrino beam from KEK towards Superkamiokande was not discussed at the Snowmass meeting, but there has been considerable development of this idea since then. Brookhaven and KEK would use low energy neutrino beams, while FNAL and CERN would plan have medium energy beams. This report will summarize a few topics common to LBL proposals and attempt to give a snapshot of where things stand in this fast developing field

  6. Gender-Specific Differences in Baseline, Peak, and Delta Serum Creatinine: The NACSELD Experience.

    Science.gov (United States)

    O'Leary, Jacqueline G; Wong, Florence; Reddy, K Rajender; Garcia-Tsao, Guadalupe; Kamath, Patrick S; Biggins, Scott W; Fallon, Michael B; Subramanian, Ram M; Maliakkal, B; Thacker, Leroy; Bajaj, Jasmohan S

    2017-03-01

    Women have lower serum creatinine values than men for similar renal function. We aimed to determine the differential effect of baseline, peak, and delta creatinine between genders on outcomes in infected hospitalized cirrhotic patients. North American Consortium for the Study of End-Stage Liver Disease is a 15-center consortium of tertiary care hepatology centers prospectively enrolling infected cirrhotic inpatients. Baseline, peak, and delta creatinine during hospitalization were compared between genders, and their impact on overall survival, transplant-free survival, probability of transplantation, and need for renal replacement therapy (RRT) was analyzed. In total, 532 patients with cirrhosis (males = 59% median admission MELD = 20) had significantly lower median baseline (1.07 vs. 1.30 mg/dL, p creatinine (1.47 vs. 1.59 mg/dL, p = 0.024) in women than men during hospitalization for an infection, but both genders had similar delta creatinine levels (0.30 vs. 0.30 mg/dL, p = 0.957). Thirty-day mortality was similar between genders. RRT was not used more often in women (19 vs. 12%, p = 0.050), and women were 1.8 times more likely than men to receive RRT at the same creatinine (p = 0.028). Both peak and delta creatinine significantly predicted 6-month overall and transplant-free survival (p creatinine. Infected hospitalized cirrhotic women are significantly more likely than men to receive RRT at similar creatinine levels. Gender-specific differences in baseline, peak, and delta creatinine need further investigation to determine whether women need acute kidney injury treatment at lower creatinine thresholds than men.

  7. 40 CFR 80.1285 - How does a refiner apply for a benzene baseline?

    Science.gov (United States)

    2010-07-01

    ... baseline? 80.1285 Section 80.1285 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (abt) Program § 80.1285 How does a refiner apply for a benzene baseline? (a) A benzene baseline... credits. (b) For U.S. Postal delivery, the benzene baseline application shall be sent to: Attn: MSAT2...

  8. Cumulative Effects of Concussion History on Baseline Computerized Neurocognitive Test Scores: Systematic Review and Meta-analysis.

    Science.gov (United States)

    Alsalaheen, Bara; Stockdale, Kayla; Pechumer, Dana; Giessing, Alexander; He, Xuming; Broglio, Steven P

    It is unclear whether individuals with a history of single or multiple clinically recovered concussions exhibit worse cognitive performance on baseline testing compared with individuals with no concussion history. To analyze the effects of concussion history on baseline neurocognitive performance using a computerized neurocognitive test. PubMed, CINAHL, and psycINFO were searched in November 2015. The search was supplemented by a hand search of references. Studies were included if participants completed the Immediate Post-concussion Assessment and Cognitive Test (ImPACT) at baseline (ie, preseason) and if performance was stratified by previous history of single or multiple concussions. Systematic review and meta-analysis. Level 2. Sample size, demographic characteristics of participants, as well as performance of participants on verbal memory, visual memory, visual-motor processing speed, and reaction time were extracted from each study. A random-effects pooled meta-analysis revealed that, with the exception of worsened visual memory for those with 1 previous concussion (Hedges g = 0.10), no differences were observed between participants with 1 or multiple concussions compared with participants without previous concussions. With the exception of decreased visual memory based on history of 1 concussion, history of 1 or multiple concussions was not associated with worse baseline cognitive performance.

  9. IEA Wind Task 26: Offshore Wind Farm Baseline Documentation

    Energy Technology Data Exchange (ETDEWEB)

    Smart, Gavin [Offshore Renewable Energy Catapult, Blyth, Northumberland (United Kingdom); Smith, Aaron [National Renewable Energy Lab. (NREL), Golden, CO (United States); Warner, Ethan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sperstad, Iver Bakken [SINTEF Energy Research, Trondheim (Norway); Prinsen, Bob [Ecofys, Utrecht (Netherlands). TKI Wind Op Zee; Lacal-Arantegui, Roberto [European Commission Joint Research Centre (JRC), Brussels (Belgium)

    2016-06-02

    This document has been produced to provide the definition and rationale for the Baseline Offshore Wind Farm established within IEA Wind Task 26--Cost of Wind Energy. The Baseline has been developed to provide a common starting point for country comparisons and sensitivity analysis on key offshore wind cost and value drivers. The baseline project reflects an approximate average of the characteristics of projects installed between 2012 and 2014, with the project life assumed to be 20 years. The baseline wind farm is located 40 kilometres (km) from construction and operations and maintenance (O&M) ports and from export cable landfall. The wind farm consists of 100 4-megawatt (MW) wind turbines mounted on monopile foundations in an average water depth of 25 metres (m), connected by 33-kilovolt (kV) inter-array cables. The arrays are connected to a single offshore substation (33kV/220kV) mounted on a jacket foundation, with the substation connected via a single 220kV export cable to an onshore substation, 10km from landfall. The wind farm employs a port-based O&M strategy using crew-transfer vessels.

  10. Consideration of the baseline environment in examples of voluntary SEAs from Scotland

    International Nuclear Information System (INIS)

    Wright, Fiona

    2007-01-01

    Evidence from analysing and evaluating examples of three voluntary SEAs prepared in Scotland in the mid-late 1990s showed that different spatial and temporal scales were used when providing a baseline environment description. The SEAs analysed were prepared for: a wind farm siting programme that looked at national and short-term impacts; a land use plan that looked at regional and short-term impacts; and a transport plan that examined local and medium-term impacts. It was found that the two SEAs prepared by local government only considered impacts on the baseline environment within their jurisdictional boundaries whilst the SEA prepared by the private business considered impacts on the national baseline. A mixture of baseline data about planning, economic, environmental and social issues were included in the SEAs, however, evidence suggested that each SEA only focussed on those baseline features that might be significantly affected by the proposal. Each SEA also made extensive use of existing baseline information available from a variety of sources including local, and central government records and information from statutory bodies. All of the SEAs acknowledged that baseline data deficiencies existed and in certain cases steps were taken to obtain primary field data to help address these, however, it was also acknowledged that resource restrictions and decision-making deadlines limited the amount of primary baseline data that could be collected

  11. Baseline Physiologic and Psychosocial Characteristics of Transgender Youth Seeking Care for Gender Dysphoria.

    Science.gov (United States)

    Olson, Johanna; Schrager, Sheree M; Belzer, Marvin; Simons, Lisa K; Clark, Leslie F

    2015-10-01

    The purpose of this study was to describe baseline characteristics of participants in a prospective observational study of transgender youth (aged 12-24 years) seeking care for gender dysphoria at a large, urban transgender youth clinic. Eligible participants presented consecutively for care at between February 2011 and June 2013 and completed a computer-assisted survey at their initial study visit. Physiologic data were abstracted from medical charts. Data were analyzed by descriptive statistics, with limited comparisons between transmasculine and transfeminine participants. A total of 101 youth were evaluated for physiologic parameters, 96 completed surveys assessing psychosocial parameters. About half (50.5%) of the youth were assigned a male sex at birth. Baseline physiologic values were within normal ranges for assigned sex at birth. Youth recognized gender incongruence at a mean age of 8.3 years (standard deviation = 4.5), yet disclosed to their family much later (mean = 17.1; standard deviation = 4.2). Gender dysphoria was high among all participants. Thirty-five percent of the participants reported depression symptoms in the clinical range. More than half of the youth reported having thought about suicide at least once in their lifetime, and nearly a third had made at least one attempt. Baseline physiologic parameters were within normal ranges for assigned sex at birth. Transgender youth are aware of the incongruence between their internal gender identity and their assigned sex at early ages. Prevalence of depression and suicidality demonstrates that youth may benefit from timely and appropriate intervention. Evaluation of these youth over time will help determine the impact of medical intervention and mental health therapy. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  12. 200-BP-5 operable unit Technical Baseline report

    International Nuclear Information System (INIS)

    Jacques, I.D.; Kent, S.K.

    1991-10-01

    This report supports development of a remedial investigation/feasibility study work plan for the 200-BP-5 operable unit. The report summarizes baseline information for waste sites and unplanned release sites located in the 200-BP-5 operable unit. The sites were investigated by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The investigation consisted of review and evaluation of current and historical Hanford Site reports, drawings, and photographs, and was supplemented with recent inspections of the Hanford Site and employee interviews. No field investigations or sampling were conducted

  13. Environmental baselines: preparing for shale gas in the UK

    Science.gov (United States)

    Bloomfield, John; Manamsa, Katya; Bell, Rachel; Darling, George; Dochartaigh, Brighid O.; Stuart, Marianne; Ward, Rob

    2014-05-01

    Groundwater is a vital source of freshwater in the UK. It provides almost 30% of public water supply on average, but locally, for example in south-east England, it is constitutes nearly 90% of public supply. In addition to public supply, groundwater has a number of other uses including agriculture, industry, and food and drink production. It is also vital for maintaining river flows especially during dry periods and so is essential for maintaining ecosystem health. Recently, there have been concerns expressed about the potential impacts of shale gas development on groundwater. The UK has abundant shales and clays which are currently the focus of considerable interest and there is active research into their characterisation, resource evaluation and exploitation risks. The British Geological Survey (BGS) is undertaking research to provide information to address some of the environmental concerns related to the potential impacts of shale gas development on groundwater resources and quality. The aim of much of this initial work is to establish environmental baselines, such as a baseline survey of methane occurrence in groundwater (National methane baseline study) and the spatial relationships between potential sources and groundwater receptors (iHydrogeology project), prior to any shale gas exploration and development. The poster describes these two baseline studies and presents preliminary findings. BGS are currently undertaking a national survey of baseline methane concentrations in groundwater across the UK. This work will enable any potential future changes in methane in groundwater associated with shale gas development to be assessed. Measurements of methane in potable water from the Cretaceous, Jurassic and Triassic carbonate and sandstone aquifers are variable and reveal methane concentrations of up to 500 micrograms per litre, but the mean value is relatively low at documented in the range 2km. The geological modelling process will be presented and discussed

  14. Evidence of the shifting baseline syndrome in ethnobotanical research.

    Science.gov (United States)

    Hanazaki, Natalia; Herbst, Dannieli Firme; Marques, Mel Simionato; Vandebroek, Ina

    2013-11-14

    The shifting baseline syndrome is a concept from ecology that can be analyzed in the context of ethnobotanical research. Evidence of shifting baseline syndrome can be found in studies dealing with intracultural variation of knowledge, when knowledge from different generations is compared and combined with information about changes in the environment and/or natural resources. We reviewed 84 studies published between 1993 and 2012 that made comparisons of ethnobotanical knowledge according to different age classes. After analyzing these studies for evidence of the shifting baseline syndrome (lower knowledge levels in younger generations and mention of declining abundance of local natural resources), we searched within these studies for the use of the expressions "cultural erosion", "loss of knowledge", or "acculturation". The studies focused on different groups of plants (e.g. medicinal plants, foods, plants used for general purposes, or the uses of specific important species). More than half of all 84 studies (57%) mentioned a concern towards cultural erosion or knowledge loss; 54% of the studies showed evidence of the shifting baseline syndrome; and 37% of the studies did not provide any evidence of shifting baselines (intergenerational knowledge differences but no information available about the abundance of natural resources). The general perception of knowledge loss among young people when comparing ethnobotanical repertoires among different age groups should be analyzed with caution. Changes in the landscape or in the abundance of plant resources may be associated with changes in ethnobotanical repertoires held by people of different age groups. Also, the relationship between the availability of resources and current plant use practices rely on a complexity of factors. Fluctuations in these variables can cause changes in the reference (baseline) of different generations and consequently be responsible for differences in intergenerational knowledge. Unraveling

  15. A proposal to create an extension to the European baseline series.

    Science.gov (United States)

    Wilkinson, Mark; Gallo, Rosella; Goossens, An; Johansen, Jeanne D; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Schuttelaar, Marie L; Uter, Wolfgang

    2018-02-01

    The current European baseline series consists of 30 allergens, and was last updated in 2015. To use data from the European Surveillance System on Contact Allergies (ESSCA) to propose an extension to the European baseline series in response to changes in environmental exposures. Data from departmental and national extensions to the baseline series, together with some temporary additions from departments contributing to the ESSCA, were collated during 2013-2014. In total, 31689 patients were patch tested in 46 European departments. Many departments and national groups already consider the current European baseline series to be a suboptimal screen, and use their own extensions to it. The haptens tested are heterogeneous, although there are some consistent themes. Potential haptens to include in an extension to the European baseline series comprise sodium metabisulfite, formaldehyde-releasing preservatives, additional markers of fragrance allergy, propolis, Compositae mix, and 2-hydroxyethyl methacrylate. In combination with other published work from the ESSCA, changes to the current European baseline series are proposed for discussion. As well as addition of the allergens listed above, it is suggested that primin and clioquinol should be deleted from the series, owing to reduced environmental exposure. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Baselines and test data for cross-lingual inference

    DEFF Research Database (Denmark)

    Agic, Zeljko; Schluter, Natalie

    2018-01-01

    The recent years have seen a revival of interest in textual entailment, sparked by i) the emergence of powerful deep neural network learners for natural language processing and ii) the timely development of large-scale evaluation datasets such as SNLI. Recast as natural language inference......, the problem now amounts to detecting the relation between pairs of statements: they either contradict or entail one another, or they are mutually neutral. Current research in natural language inference is effectively exclusive to English. In this paper, we propose to advance the research in SNLI-style natural...... language inference toward multilingual evaluation. To that end, we provide test data for four major languages: Arabic, French, Spanish, and Russian. We experiment with a set of baselines. Our systems are based on cross-lingual word embeddings and machine translation. While our best system scores an average...

  17. Very Long Baseline Interferometry: Dependencies on Frequency Stability

    Science.gov (United States)

    Nothnagel, Axel; Nilsson, Tobias; Schuh, Harald

    2018-04-01

    Very Long Baseline Interferometry (VLBI) is a differential technique observing radiation of compact extra-galactic radio sources with pairs of radio telescopes. For these observations, the frequency standards at the telescopes need to have very high stability. In this article we discuss why this is, and we investigate exactly how precise the frequency standards need to be. Four areas where good clock performance is needed are considered: coherence, geodetic parameter estimation, correlator synchronization, and UT1 determination. We show that in order to ensure the highest accuracy of VLBI, stability similar to that of a hydrogen maser is needed for time-scales up to a few hours. In the article, we are considering both traditional VLBI where extra-galactic radio sources are observed, as well as observation of man-made artificial radio sources emitted by satellites or spacecrafts.

  18. Improving Ambiguity Resolution for Medium Baselines Using Combined GPS and BDS Dual/Triple-Frequency Observations.

    Science.gov (United States)

    Gao, Wang; Gao, Chengfa; Pan, Shuguo; Wang, Denghui; Deng, Jiadong

    2015-10-30

    The regional constellation of the BeiDou navigation satellite system (BDS) has been providing continuous positioning, navigation and timing services since 27 December 2012, covering China and the surrounding area. Real-time kinematic (RTK) positioning with combined BDS and GPS observations is feasible. Besides, all satellites of BDS can transmit triple-frequency signals. Using the advantages of multi-pseudorange and carrier observations from multi-systems and multi-frequencies is expected to be of much benefit for ambiguity resolution (AR). We propose an integrated AR strategy for medium baselines by using the combined GPS and BDS dual/triple-frequency observations. In the method, firstly the extra-wide-lane (EWL) ambiguities of triple-frequency system, i.e., BDS, are determined first. Then the dual-frequency WL ambiguities of BDS and GPS were resolved with the geometry-based model by using the BDS ambiguity-fixed EWL observations. After that, basic (i.e., L1/L2 or B1/B2) ambiguities of BDS and GPS are estimated together with the so-called ionosphere-constrained model, where the ambiguity-fixed WL observations are added to enhance the model strength. During both of the WL and basic AR, a partial ambiguity fixing (PAF) strategy is adopted to weaken the negative influence of new-rising or low-elevation satellites. Experiments were conducted and presented, in which the GPS/BDS dual/triple-frequency data were collected in Nanjing and Zhengzhou of China, with the baseline distance varying from about 28.6 to 51.9 km. The results indicate that, compared to the single triple-frequency BDS system, the combined system can significantly enhance the AR model strength, and thus improve AR performance for medium baselines with a 75.7% reduction of initialization time on average. Besides, more accurate and stable positioning results can also be derived by using the combined GPS/BDS system.

  19. 41 CFR 109-1.5202 - Establishment of a personal property holdings baseline.

    Science.gov (United States)

    2010-07-01

    ... personal property holdings baseline. 109-1.5202 Section 109-1.5202 Public Contracts and Property Management...-1.5202 Establishment of a personal property holdings baseline. (a) If the contractor is a new... baseline or may perform a complete physical inventory of all personal property. This physical inventory is...

  20. A comparison of different ways of including baseline counts in negative binomial models for data from falls prevention trials.

    Science.gov (United States)

    Zheng, Han; Kimber, Alan; Goodwin, Victoria A; Pickering, Ruth M

    2018-01-01

    A common design for a falls prevention trial is to assess falling at baseline, randomize participants into an intervention or control group, and ask them to record the number of falls they experience during a follow-up period of time. This paper addresses how best to include the baseline count in the analysis of the follow-up count of falls in negative binomial (NB) regression. We examine the performance of various approaches in simulated datasets where both counts are generated from a mixed Poisson distribution with shared random subject effect. Including the baseline count after log-transformation as a regressor in NB regression (NB-logged) or as an offset (NB-offset) resulted in greater power than including the untransformed baseline count (NB-unlogged). Cook and Wei's conditional negative binomial (CNB) model replicates the underlying process generating the data. In our motivating dataset, a statistically significant intervention effect resulted from the NB-logged, NB-offset, and CNB models, but not from NB-unlogged, and large, outlying baseline counts were overly influential in NB-unlogged but not in NB-logged. We conclude that there is little to lose by including the log-transformed baseline count in standard NB regression compared to CNB for moderate to larger sized datasets. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. 75 FR 30014 - Consumers Energy Company; Notice of Baseline Filing

    Science.gov (United States)

    2010-05-28

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-25-000] Consumers Energy Company; Notice of Baseline Filing May 21, 2010. Take notice that on May 17, 2010, Consumers Energy Company (Consumers) submitted a baseline filing of its Statement of Operating Conditions for the...

  2. [The prognostic value of baseline serum free light chain in cardiac amyloidosis].

    Science.gov (United States)

    Zhao, Lei; Tian, Zhuang; Fang, Quan

    2016-03-01

    To analyze the prognostic value of baseline serum free light chain (sFLC) in light-chain (AL) cardiac amyloidosis. Twenty-seven patients with AL cardiac amyloidosis were retrospectively reviewed from January 2014 to January 2015. sFLC was measured by immuoturbidimetric assay. Baseline characteristics, echocardiographic parameters and electrocardiogram data were analyzed. According to the median baseline dFLC (involved sFLC minus uninvolved sFLC), patients were categorized into either the low dFLC(≤ 307 mg/L) or the high dFLC group (>307 mg/L). More subjects in the high dFLC group with early/late diastolic mitral velocity ratio (E/A ratio) over 2 (71.4% vs 30.8%, P=0.035), and subjects in this group had a shorter median survival time than those in the low dFLC group (3 months vs 17 months, P=0.004). A similar phenomenon for median survival time was observed when the subjects were redivided either by a new cut-off value of 180 mg/L for dFLC (low dFLC group: 17 months; high dFLC group: 4 months, P=0.014) or a κ/λ ratio, in which subjects with κ type sFLC-ratio ≤ 19.6 and λ type sFLC-ratio>0.065 were in the low sFLC-ratio group (17 months) and those with κ type sFLC-ratio > 19.6 and λ type sFLC-ratio ≤ 0.065 were in the high sFLC-ratio group (4 months, P=0.023). In multivariate analysis, dFLC and New York Heart Association (NYHA)classification of cardiac function were two risk factors associated with all-cause mortality in patients, among which the hazard ratio for higher dFLC was 4.28 (95%CI 1.55-11.8, P=0.005). The level of sFLC could be a marker for the prognosis of AL cardiac amyloidosis.

  3. Evolved Phenological Asynchrony as a Baseline for Climate-change Impacts. (Invited)

    Science.gov (United States)

    Singer, M. C.; Parmesan, C.

    2010-12-01

    Changing climate can disrupt existing phenological relations between interacting species. We might expect the historical baseline for these effects to be precise synchrony between the season at which a consumer most requires food and the time when its resources are most available. When this is the case, change in any direction would be detrimental to the consumer. But is baseline synchrony the appropriate assumption? Here, we develop the theme that the starting point for climate change impacts may often have been asynchrony or mismatch between consumer and resource. To the extent that this has been true, assumptions of baseline synchrony risk mis-detection, mis-estimation, and mis-attribution of climate change impacts. Natural selection can result in asynchrony between exploiter and victim when victims successfully evolve to occupy enemy-free time. Asynchrony can also result from life-history tradedoffs. We illustrate asynchrony arising from tradeoffs for two species: Edith’s checkerspot butterfly and the winter moth. Initial observations of phenological mismatch in both systems were made prior to the onset of major impacts of anthropogenically-driven climate change. Neither species can detect the phenological stage of its host plants with precision. In both species, evolution of life history has involved compromise between maximizing fecundity and minimizing mortality, with the outcome being superficially maladaptive strategies in which many or even most individuals die of starvation through poor synchrony with their host plants. Both species have evolved high-risk life history strategies. While winter moth eggs gamble with their own lives by hatching early, bay checkerspots gamble with the lives of their offspring by growing large and eclosing late as adults. In both cases the result is the evolution of populations in which large numbers of individuals die because, as individuals, they fail to fit their life cycles into the available timespan. Because such a

  4. Technical Design Report for large-scale neutrino detectors prototyping and phased performance assessment in view of a long-baseline oscillation experiment

    CERN Document Server

    De Bonis, I.; Duchesneau, D.; Pessard, H.; Bordoni, S.; Ieva, M.; Lux, T.; Sanchez, F.; Jipa, A.; Lazanu, I.; Calin, M.; Esanu, T.; Ristea, O.; Ristea, C.; Nita, L.; Efthymiopoulos, I.; Nessi, M.; Asfandiyarov, R.; Blondel, A.; Bravar, A.; Cadoux, F.; Haesler, A.; Karadzhov, Y.; Korzenev, A.; Martin, C.; Noah, E.; Ravonel, M.; Rayner, M.; Scantamburlo, E.; Bayes, R.; Soler, F.J.P.; Nuijten, G.A.; Loo, K.; Maalampi, J.; Slupecki, M.; Trzaska, W.H.; Campanelli, M.; Blebea-Apostu, A.M.; Chesneanu, D.; Gomoiu, M.C; Mitrica, B.; Margineanu, R.M.; Stanca, D.L.; Colino, N.; Gil-Botella, I.; Novella, P.; Palomares, C.; Santorelli, R.; Verdugo, A.; Karpikov, I.; Khotjantsev, A.; Kudenko, Y.; Mefodiev, A.; Mineev, O.; Ovsiannikova, T.; Yershov, N.; Enqvist, T.; Kuusiniemi, P.; De La Taille, C.; Dulucq, F.; Martin-Chassard, G.; Andrieu, B.; Dumarchez, J.; Giganti, C.; Levy, J.-M.; Popov, B.; Robert, A.; Agostino, L.; Buizza-Avanzini, M.; Dawson, J.; Franco, D.; Gorodetzky, P.; Kryn, D.; Patzak, T.; Tonazzo, A.; Vannucci, F.; Bésida, O.; Bolognesi, S.; Delbart, A.; Emery, S.; Galymov, V.; Mazzucato, E.; Vasseur, G.; Zito, M.; Bogomilov, M.; Tsenov, R.; Vankova-Kirilova, G.; Friend, M.; Hasegawa, T.; Nakadaira, T.; Sakashita, K.; Zambelli, L.; Autiero, D.; Caiulo, D.; Chaussard, L.; Déclais, Y.; Franco, D.; Marteau, J.; Pennacchio, E.; Bay, F.; Cantini, C.; Crivelli, P.; Epprecht, L.; Gendotti, A.; Di Luise, S.; Horikawa, S.; Murphy, S.; Nikolics, K.; Periale, L.; Regenfus, C.; Rubbia, A.; Sgalaberna, D.; Viant, T.; Wu, S.; Sergiampietri, F.; CERN. Geneva. SPS and PS Experiments Committee; SPSC

    2014-01-01

    In June 2012, an Expression of Interest for a long-baseline experiment (LBNO, CERN-SPSC-EOI-007) has been submitted to the CERN SPSC and is presently under review. LBNO considers three types of neutrino detector technologies: a double-phase liquid argon (LAr) TPC and a magnetised iron detector as far detectors. For the near detector, a high-pressure gas TPC embedded in a calorimeter and a magnet is the baseline design. A mandatory milestone in view of any future long baseline experiment is a concrete prototyping effort towards the envisioned large-scale detectors, and an accompanying campaign of measurements aimed at assessing the systematic errors that will be affecting their intended physics programme. Following an encouraging feedback from 108th SPSC on the technology choices, we have defined as priority the construction and operation of a $6\\times 6\\times 6$m$^3$ (active volume) double-phase liquid argon (DLAr) demonstrator, and a parallel development of the technologies necessary for large magnetised MIN...

  5. Waste management project technical baseline description

    International Nuclear Information System (INIS)

    Sederburg, J.P.

    1997-01-01

    A systems engineering approach has been taken to describe the technical baseline under which the Waste Management Project is currently operating. The document contains a mission analysis, function analysis, requirement analysis, interface definitions, alternative analysis, system definition, documentation requirements, implementation definitions, and discussion of uncertainties facing the Project

  6. Leisure-time physical activity, sedentary behaviors, sleep, and cardiometabolic risk factors at baseline in the PREDIMED-PLUS intervention trial: A cross-sectional analysis.

    Directory of Open Access Journals (Sweden)

    Nuria Rosique-Esteban

    Full Text Available Limited data exists on the interrelationships between physical activity (PA, sedentary behaviors and sleep concerning cardiometabolic risk factors in aged adults at high cardiovascular disease risk. Our aim was to examine independent and joint associations between time spent in leisure-time PA, sedentary behaviors and sleep on the prevalence of obesity, type 2 diabetes (T2D and components of the metabolic syndrome (MetS in Mediterranean individuals at high cardiovascular risk. Cross-sectional analyses were performed on baseline data from 5776 Spanish adults (aged 55-75y in men; 60-75y in women with overweight/obesity and MetS, from October 2013 to October 2016, in the PREDIMED-PLUS trial. Employing multivariable-adjusted Cox regression with robust variance and constant time (given the cross-sectional design, higher prevalence of obesity, T2D and abdominal obesity as component of the MetS were associated with greater time in TV-viewing (Relative Risk, RR: 1.02, 95%CI: 1.01, 1.03; RR:1.04, 95%CI: 1.02, 1.06 and RR: 1.01 95%CI: 1.00, 1.02; respectively, all P < .01. Conversely, greater time in moderate-vigorous PA (MVPA was associated with lower prevalence of obesity, T2D, abdominal obesity and low HDL-cholesterol (RR: 0.95, 95%CI: 0.93, 0.97; RR: 0.94, 95%CI: 0.89, 0.99; RR: 0.97, 95%CI: 0.96, 0.98; and RR: 0.95, 95%CI: 0.91, 0.99, respectively, all P < .05. For these outcomes, theoretically substituting 1-h/day of MVPA for 1-h/day TV-viewing was also significantly associated with lower prevalence (RR 0.91 to 0.97, all P < .05. Similar lower RR in these outcomes was observed when substituting 1-h/day of MVPA for 1-h/day of sleeping. Longer time watching TV and not meeting MVPA recommendations were jointly associated with higher RR of the prevalence of obesity and T2D. We concluded that, in senior individuals at high cardiovascular risk, greater time spent on MVPA and fewer on sedentary behaviors was inversely associated with prevalence of obesity

  7. Historical baselines of coral cover on tropical reefs as estimated by expert opinion

    Directory of Open Access Journals (Sweden)

    Tyler D. Eddy

    2018-01-01

    Full Text Available Coral reefs are important habitats that represent global marine biodiversity hotspots and provide important benefits to people in many tropical regions. However, coral reefs are becoming increasingly threatened by climate change, overfishing, habitat destruction, and pollution. Historical baselines of coral cover are important to understand how much coral cover has been lost, e.g., to avoid the ‘shifting baseline syndrome’. There are few quantitative observations of coral reef cover prior to the industrial revolution, and therefore baselines of coral reef cover are difficult to estimate. Here, we use expert and ocean-user opinion surveys to estimate baselines of global coral reef cover. The overall mean estimated baseline coral cover was 59% (±19% standard deviation, compared to an average of 58% (±18% standard deviation estimated by professional scientists. We did not find evidence of the shifting baseline syndrome, whereby respondents who first observed coral reefs more recently report lower estimates of baseline coral cover. These estimates of historical coral reef baseline cover are important for scientists, policy makers, and managers to understand the extent to which coral reefs have become depleted and to set appropriate recovery targets.

  8. Historical baselines of coral cover on tropical reefs as estimated by expert opinion.

    Science.gov (United States)

    Eddy, Tyler D; Cheung, William W L; Bruno, John F

    2018-01-01

    Coral reefs are important habitats that represent global marine biodiversity hotspots and provide important benefits to people in many tropical regions. However, coral reefs are becoming increasingly threatened by climate change, overfishing, habitat destruction, and pollution. Historical baselines of coral cover are important to understand how much coral cover has been lost, e.g., to avoid the 'shifting baseline syndrome'. There are few quantitative observations of coral reef cover prior to the industrial revolution, and therefore baselines of coral reef cover are difficult to estimate. Here, we use expert and ocean-user opinion surveys to estimate baselines of global coral reef cover. The overall mean estimated baseline coral cover was 59% (±19% standard deviation), compared to an average of 58% (±18% standard deviation) estimated by professional scientists. We did not find evidence of the shifting baseline syndrome, whereby respondents who first observed coral reefs more recently report lower estimates of baseline coral cover. These estimates of historical coral reef baseline cover are important for scientists, policy makers, and managers to understand the extent to which coral reefs have become depleted and to set appropriate recovery targets.

  9. Exploring non standard physics in long-baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Chatterjee, Sabya Sachi

    2015-01-01

    After the recent discovery of large th ( 13), the focus has been shifted to address the remaining fundamental issues like neutrino mass ordering and CP-violation in leptonic sector. Future proposed Long-Baseline facilities like DUNE (1300 km baseline from FNAL to Homestake) and LBNO (2290 km baseline from CERN to Pyhasalmi) are well suited to address these issues at high confidence level. Not only to the standard framework, these experiments are highly capable to look for some new physics beyond the Standard Model scenario. In this work, we explore whether these high precision future facilities are sensitive to new U(1) global symmetries and upto which confidence level. (author)

  10. Conservation of forest birds: evidence of a shifting baseline in community structure.

    Directory of Open Access Journals (Sweden)

    Chadwick D Rittenhouse

    2010-08-01

    Full Text Available Quantifying changes in forest bird diversity is an essential task for developing effective conservation actions. When subtle changes in diversity accumulate over time, annual comparisons may offer an incomplete perspective of changes in diversity. In this case, progressive change, the comparison of changes in diversity from a baseline condition, may offer greater insight because changes in diversity are assessed over longer periods of times. Our objectives were to determine how forest bird diversity has changed over time and whether those changes were associated with forest disturbance.We used North American Breeding Bird Survey data, a time series of Landsat images classified with respect to land cover change, and mixed-effects models to associate changes in forest bird community structure with forest disturbance, latitude, and longitude in the conterminous United States for the years 1985 to 2006. We document a significant divergence from the baseline structure for all birds of similar migratory habit and nest location, and all forest birds as a group from 1985 to 2006. Unexpectedly, decreases in progressive similarity resulted from small changes in richness (<1 species per route for the 22-year study period and modest losses in abundance (-28.7 - -10.2 individuals per route that varied by migratory habit and nest location. Forest disturbance increased progressive similarity for Neotropical migrants, permanent residents, ground nesting, and cavity nesting species. We also documented highest progressive similarity in the eastern United States.Contemporary forest bird community structure is changing rapidly over a relatively short period of time (e.g., approximately 22 years. Forest disturbance and forest regeneration are primary factors associated with contemporary forest bird community structure, longitude and latitude are secondary factors, and forest loss is a tertiary factor. Importantly, these findings suggest some regions of the United

  11. 77 FR 31841 - Hope Gas, Inc.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-23-001] Hope Gas, Inc.; Notice of Baseline Filing Take notice that on May 16, 2012, Hope Gas, Inc. (Hope Gas) submitted a revised baseline filing of their Statement of Operating Conditions for services provided under Section 311 of the...

  12. 77 FR 26535 - Hope Gas, Inc.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-04

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-23-000] Hope Gas, Inc.; Notice of Baseline Filing Take notice that on April 26, 2012, Hope Gas, Inc. (Hope Gas) submitted a baseline filing of their Statement of Operating Conditions for services provided under Section 311 of the...

  13. 75 FR 33799 - EasTrans, LLC; Notice of Baseline Filing

    Science.gov (United States)

    2010-06-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-30-000] EasTrans, LLC; Notice of Baseline Filing June 8, 2010. Take notice that on June 4, 2010, EasTrans, LLC submitted a baseline filing of its Statement of Operating Conditions for services provided under section 311 of the...

  14. A Systematic Review and Meta-Analysis of Baseline Ohip-Edent Scores.

    Science.gov (United States)

    Duale, J M J; Patel, Y A; Wu, J; Hyde, T P

    2018-03-01

    OHIP-EDENT is widely used in the literature to assess Oral-Health-Related-Quality-of-Life (OHRQoL) for edentulous patients. However the normal variance and mean of the baseline OHIP scores has not been reported. It would facilitate critical appraisal of studies if we had knowledge of the normal variation and mean of baseline OHIP-EDENT scores. An established figure for baseline OHIP-EDENT, obtained from a meta-analysis, would simplify comparisons of studies and quantify variations in initial OHRQoL of the trial participants. The aim of this study is to quantify a normal baseline value for pre-operative OHIP-EDENT scores by a systematic review and meta-analysis of the available literature. A systematic literature review was carried. 83 papers were identified that included OHIP-EDENT values. After screening and eligibility assessment, 7 papers were selected and included in the meta-analysis. A meta-analysis for the 7 papers by a random-effect model yielded a mean baseline OHIP-EDENT score of 28.63 with a 95% Confidence intervals from 21.93 to 35.34. A pre-operative baseline OHIP-EDENT has been established by meta-analysis of published papers. This will facilitate the comparison of the initial OHRQoL of one study population to that found elsewhere in the published literature. Copyright© 2018 Dennis Barber Ltd.

  15. Microbunch preserving in-line system for an APPLE II helical radiator at the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL Project Team, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-05-15

    In a previous work we proposed a scheme for polarization control at the LCLS baseline, which exploited the microbunching from the planar undulator. After the baseline undulator, the electron beam is transported through a drift by a FODO focusing system, and through a short helical radiator. The microbunching structure can be preserved, and intense coherent radiation is emitted in the helical undulator at fundamental harmonic. The driving idea of this proposal is that the background linearly-polarized radiation from the baseline undulator is suppressed by spatial filtering. Filtering is achieved by letting radiation and electron beam through Be slits upstream of the helical radiator, where the radiation spot size is about ten times larger than the electron beam transverse size. Several changes considered in the present paper were made to improve the previous design. Slits are now placed immediately behind the helical radiator. The advantage is that the electron beam can be spoiled by the slits, and narrower slits width can be used for spatial filtering. Due to this fundamental reason, the present setup is shorter than the previous one. The helical radiator is now placed immediately behind the SHAB undulator. It is thus sufficient to use the existing FODO focusing system of the SHAB undulator for transporting themodulated electron beam. This paper presents complete GENESIS code calculations for the new design, starting from the baseline undulator entrance up to the helical radiator exit including the modulated electron beam transport by the SHAB FODO focusing system. (orig.)

  16. Microbunch preserving in-line system for an APPLE II helical radiator at the LCLS baseline

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-05-01

    In a previous work we proposed a scheme for polarization control at the LCLS baseline, which exploited the microbunching from the planar undulator. After the baseline undulator, the electron beam is transported through a drift by a FODO focusing system, and through a short helical radiator. The microbunching structure can be preserved, and intense coherent radiation is emitted in the helical undulator at fundamental harmonic. The driving idea of this proposal is that the background linearly-polarized radiation from the baseline undulator is suppressed by spatial filtering. Filtering is achieved by letting radiation and electron beam through Be slits upstream of the helical radiator, where the radiation spot size is about ten times larger than the electron beam transverse size. Several changes considered in the present paper were made to improve the previous design. Slits are now placed immediately behind the helical radiator. The advantage is that the electron beam can be spoiled by the slits, and narrower slits width can be used for spatial filtering. Due to this fundamental reason, the present setup is shorter than the previous one. The helical radiator is now placed immediately behind the SHAB undulator. It is thus sufficient to use the existing FODO focusing system of the SHAB undulator for transporting themodulated electron beam. This paper presents complete GENESIS code calculations for the new design, starting from the baseline undulator entrance up to the helical radiator exit including the modulated electron beam transport by the SHAB FODO focusing system. (orig.)

  17. Base-line studies for DAE establishments

    International Nuclear Information System (INIS)

    Puranik, V.D.

    2012-01-01

    The Department of Atomic Energy has establishments located in various regions of the country and they include front-end fuel cycle facilities, nuclear power stations, back-end fuel cycle facilities and facilities for research and societal applications. These facilities handle naturally occurring radionuclides such as uranium, thorium and a variety of man-made radionuclides. These radionuclides are handled with utmost care so that they do not affect adversely the occupational workers or the members of public residing nearby. There is safety culture of the highest standard existing in all DAE establishments and it matches with the international standards. In addition, there is a perpetual environmental monitoring program carried out by the Environmental Survey Laboratories (ESLs) located at all DAE establishments. The environmental data generated by such program is studied regularly by experts to ensure compliance with the regulatory requirements. The regulatory requirements in the country are of international standards and ensure adequate protection of workers and members of public. In addition to such continued monitoring program and studies being carried out for the ongoing projects, base-line studies are carried out for all the new projects of the DAE. The purpose of the base-line studies is to establish a detailed base-line data set for a new DAE location well before the foundation stone is laid, so that the data collected when there is no departmental activity can be compared with the data generated later by the ESL. The data so generated is site specific and it varies from place to place depending upon the location of the site, e.g., inland or coastal, the presence of water bodies and pattern of irrigation, the geological characteristics of the location, the local culture and habits of the people, population density and urban or rural background. The data to be recorded as base-line data is generated over a period of at least one year covering all the seasons

  18. Baseline Validation of Unstructured Grid Reynolds-Averaged Navier-Stokes Toward Flow Control

    Science.gov (United States)

    Joslin, Ronald D.; Viken, Sally A.

    2001-01-01

    experiments for the no-control case before proceeding to the time-dependent flow control case. This paper documents the baseline (no-control) case using an unswept airfoil configuration. The next section describes the configurations used for the computations and the experimentals. The computational approach is then described followed by results and concluding remarks.

  19. Three-dimensional thermal analysis of a baseline spent fuel repository

    International Nuclear Information System (INIS)

    Altenbach, T.J.; Lowry, W.E.

    1980-01-01

    A three-dimensional thermal analysis has been performed using finite difference techniques to determine the near-field response of a baseline spent fuel repository in a deep geologic salt medium. A baseline design incorporates previous thermal modeling experience and OWI recommendations for areal thermal loading in specifying the waste form properties, package details, and emplacement configuration. The base case in this thermal analysis considers one 10-year old PWR spent fuel assembly emplaced to yield a 36 kw/acre (8.9 w/m 2 ) loading. A unit cell model in an infinite array is used to simplify the problem and provide upper-bound temperatures. Boundary conditions are imposed which allow simulations to 1000 years. Variations studied include a comparison of ventilated and unventilated storage room conditions, emplacement packages with and without air gaps surrounding the canister, and room cool-down scenarios with ventilation following an unventilated state for retrieval purposes. At this low power level ventilating the emplacement room has an immediate cooling influence on the canister and effectively maintains the emplacement room floor near the temperature of the ventilating air. The annular gap separating the canister and sleeve causes the peak temperature of the canister surface to rise by 10 0 F (5.6 0 C) over that from a no gap case assuming perfect thermal contact. It was also shown that the time required for the emplacement room to cool down to 100 0 F (38 0 C) from an unventilated state ranged from 2 weeks to 6 months; when ventilation initiated after times of 5 years to 50 years, respectively. As the work was performed for the Nuclear Regulatory Commission, these results provide a significant addition to the regulatory data base for spent fuel performance in a geologic repository

  20. National Cyberethics, Cybersafety, Cybersecurity Baseline Study

    Science.gov (United States)

    Education Digest: Essential Readings Condensed for Quick Review, 2009

    2009-01-01

    This article presents findings from a study that explores the nature of the Cyberethics, Cybersafety, and Cybersecurity (C3) educational awareness policies, initiatives, curriculum, and practices currently taking place in the U.S. public and private K-12 educational settings. The study establishes baseline data on C3 awareness, which can be used…

  1. Linear MALDI-ToF simultaneous spectrum deconvolution and baseline removal.

    Science.gov (United States)

    Picaud, Vincent; Giovannelli, Jean-Francois; Truntzer, Caroline; Charrier, Jean-Philippe; Giremus, Audrey; Grangeat, Pierre; Mercier, Catherine

    2018-04-05

    Thanks to a reasonable cost and simple sample preparation procedure, linear MALDI-ToF spectrometry is a growing technology for clinical microbiology. With appropriate spectrum databases, this technology can be used for early identification of pathogens in body fluids. However, due to the low resolution of linear MALDI-ToF instruments, robust and accurate peak picking remains a challenging task. In this context we propose a new peak extraction algorithm from raw spectrum. With this method the spectrum baseline and spectrum peaks are processed jointly. The approach relies on an additive model constituted by a smooth baseline part plus a sparse peak list convolved with a known peak shape. The model is then fitted under a Gaussian noise model. The proposed method is well suited to process low resolution spectra with important baseline and unresolved peaks. We developed a new peak deconvolution procedure. The paper describes the method derivation and discusses some of its interpretations. The algorithm is then described in a pseudo-code form where the required optimization procedure is detailed. For synthetic data the method is compared to a more conventional approach. The new method reduces artifacts caused by the usual two-steps procedure, baseline removal then peak extraction. Finally some results on real linear MALDI-ToF spectra are provided. We introduced a new method for peak picking, where peak deconvolution and baseline computation are performed jointly. On simulated data we showed that this global approach performs better than a classical one where baseline and peaks are processed sequentially. A dedicated experiment has been conducted on real spectra. In this study a collection of spectra of spiked proteins were acquired and then analyzed. Better performances of the proposed method, in term of accuracy and reproductibility, have been observed and validated by an extended statistical analysis.

  2. 1st DeepWind 5 MW Baseline design

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Vita, Luca; Aagaard Madsen, Helge

    2012-01-01

    The first 5MW baseline design of the DeepWind concept is presented for a Darrieus type floating wind turbine system for water depths of more than 150 m. This design will be used as design reference to test the next technological improvements of sub-component level, being based as much as possible...... trajectory on the water plane. The generator is placed at the bottom of the platform and uses 5MW direct drive technology.The conceptual design is evaluated with numerical simulations in the time domain using the aero-elastic code HAWC2. In order to investigate the concept, a double-disc blade element....... A site has been chosen for the floating turbine off Norway as representative for external conditions. The structure is verified according to an ultimate strength analysis, including loads from wind, waves and currents. The stability of the platform is investigated, considering the displacements...

  3. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  4. A baseline for the multivariate comparison of resting state networks

    Directory of Open Access Journals (Sweden)

    Elena A Allen

    2011-02-01

    Full Text Available As the size of functional and structural MRI datasets expands, it becomes increasingly important to establish a baseline from which diagnostic relevance may be determined, a processing strategy that efficiently prepares data for analysis, and a statistical approach that identifies important effects in a manner that is both robust and reproducible. In this paper, we introduce a multivariate analytic approach that optimizes sensitivity and reduces unnecessary testing. We demonstrate the utility of this mega-analytic approach by identifying the effects of age and gender on the resting state networks of 603 healthy adolescents and adults (mean age: 23.4 years, range: 12 to 71 years. Data were collected on the same scanner, preprocessed using an automated analysis pipeline based in SPM, and studied using group independent component analysis. Resting state networks were identified and evaluated in terms of three primary outcome measures: time course spectral power, spatial map intensity, and functional network connectivity. Results revealed robust effects of age on all three outcome measures, largely indicating decreases in network coherence and connectivity with increasing age. Gender effects were of smaller magnitude but suggested stronger intra-network connectivity in females and more inter-network connectivity in males, particularly with regard to sensorimotor networks. These findings, along with the analysis approach and statistical framework described here, provide a useful baseline for future investigations of brain networks in health and disease.

  5. A Baseline for the Multivariate Comparison of Resting-State Networks

    Science.gov (United States)

    Allen, Elena A.; Erhardt, Erik B.; Damaraju, Eswar; Gruner, William; Segall, Judith M.; Silva, Rogers F.; Havlicek, Martin; Rachakonda, Srinivas; Fries, Jill; Kalyanam, Ravi; Michael, Andrew M.; Caprihan, Arvind; Turner, Jessica A.; Eichele, Tom; Adelsheim, Steven; Bryan, Angela D.; Bustillo, Juan; Clark, Vincent P.; Feldstein Ewing, Sarah W.; Filbey, Francesca; Ford, Corey C.; Hutchison, Kent; Jung, Rex E.; Kiehl, Kent A.; Kodituwakku, Piyadasa; Komesu, Yuko M.; Mayer, Andrew R.; Pearlson, Godfrey D.; Phillips, John P.; Sadek, Joseph R.; Stevens, Michael; Teuscher, Ursina; Thoma, Robert J.; Calhoun, Vince D.

    2011-01-01

    As the size of functional and structural MRI datasets expands, it becomes increasingly important to establish a baseline from which diagnostic relevance may be determined, a processing strategy that efficiently prepares data for analysis, and a statistical approach that identifies important effects in a manner that is both robust and reproducible. In this paper, we introduce a multivariate analytic approach that optimizes sensitivity and reduces unnecessary testing. We demonstrate the utility of this mega-analytic approach by identifying the effects of age and gender on the resting-state networks (RSNs) of 603 healthy adolescents and adults (mean age: 23.4 years, range: 12–71 years). Data were collected on the same scanner, preprocessed using an automated analysis pipeline based in SPM, and studied using group independent component analysis. RSNs were identified and evaluated in terms of three primary outcome measures: time course spectral power, spatial map intensity, and functional network connectivity. Results revealed robust effects of age on all three outcome measures, largely indicating decreases in network coherence and connectivity with increasing age. Gender effects were of smaller magnitude but suggested stronger intra-network connectivity in females and more inter-network connectivity in males, particularly with regard to sensorimotor networks. These findings, along with the analysis approach and statistical framework described here, provide a useful baseline for future investigations of brain networks in health and disease. PMID:21442040

  6. Circular polarization control for the LCLS baseline in the soft X-ray regime

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2010-12-15

    The LCLS baseline includes a planar undulator system, which produces intense linearly polarized light in the wavelength range 0.15-1.5 nm. In the soft X-ray wavelength region polarization control from linear to circular is highly desirable for studying ultrafast magnetic phenomena and material science issues. Several schemes using helical undulators have been discussed in the context of the LCLS. One consists in replacing three of the last planar undulator segments by helical (APPLE III) ones. A second proposal, the 2nd harmonic helical afterburner, is based on the use of short, crossed undulators tuned to the second harmonic. This last scheme is expected to be the better one. Its advantages are a high (over 90%) and stable degree of circular polarization and a low cost. Its disadvantage is a small output power (1% of the power at the fundamental harmonic) and a narrow wavelength range. We propose a novel method to generate 10 GW level power at the fundamental harmonic with 99% degree of circular polarization from the LCLS baseline. Its merits are low cost, simplicity and easy implementation. In the option presented here, the microbunching of the planar undulator is used too. After the baseline undulator, the electron beam is sent through a 40 m long straight section, and subsequently passes through a short helical (APPLE II) radiator. In this case the microbunch structure is easily preserved, and intense coherent radiation is emitted in the helical radiator. The background radiation from the baseline undulator can be easily suppressed by letting radiation and electron beamthrough horizontal and vertical slits upstream the helical radiator, where the radiation spot size is about ten times larger than the electron bunch transverse size. Using thin Beryllium foils for the slits the divergence of the electron beam halo will increase by Coulomb scattering, but the beam will propagate through the setup without electron losses. The applicability of our method is not

  7. Experimental increase in baseline corticosterone level reduces oxidative damage and enhances innate immune response.

    Directory of Open Access Journals (Sweden)

    Csongor I Vágási

    Full Text Available Glucocorticoid (GC hormones are significant regulators of homeostasis. The physiological effects of GCs critically depend on the time of exposure (short vs. long as well as on their circulating levels (baseline vs. stress-induced. Previous experiments, in which chronic and high elevation of GC levels was induced, indicate that GCs impair both the activity of the immune system and the oxidative balance. Nonetheless, our knowledge on how mildly elevated GC levels, a situation much more common in nature, might influence homeostasis is limited. Therefore, we studied whether an increase in GC level within the baseline range suppresses or enhances condition (body mass, hematocrit and coccidian infestation and physiological state (humoral innate immune system activity and oxidative balance. We implanted captive house sparrows Passer domesticus with either 60 days release corticosterone (CORT or control pellets. CORT-treated birds had elevated baseline CORT levels one week after the implantation, but following this CORT returned to its pre-treatment level and the experimental groups had similar CORT levels one and two months following the implantation. The mass of tail feathers grown during the initial phase of treatment was smaller in treated than in control birds. CORT implantation had a transient negative effect on body mass and hematocrit, but both of these traits resumed the pre-treatment values by one month post-treatment. CORT treatment lowered oxidative damage to lipids (malondialdehyde and enhanced constitutive innate immunity at one week and one month post-implantation. Our findings suggest that a relatively short-term (i.e. few days elevation of baseline CORT might have a positive and stimulatory effect on animal physiology.

  8. Safety Evaluation of the ESP Sludge Washing Baselines Runs. Revision 1

    International Nuclear Information System (INIS)

    Gupta, M.K.

    1994-08-01

    The purpose is to provide the technical basis for the evaluation of Unreviewed Safety Question for the Extended Sludge Processing (ESP) Sludge Washing Baseline Runs. The Baseline runs are necessary: to ascertain the mechanical fitness of the equipment and modifications not operated since 1988 and to resolve technical questions associated with process control; i.e., sludge suspension, sludge settling, heat transfer, and temperature control. These issues need to be resolved prior to resumption of normal ESP operations. The equipment used for the Baseline runs are Tanks 42H and 51H and their associated equipment

  9. Network meta-analysis of disconnected networks: How dangerous are random baseline treatment effects?

    Science.gov (United States)

    Béliveau, Audrey; Goring, Sarah; Platt, Robert W; Gustafson, Paul

    2017-12-01

    In network meta-analysis, the use of fixed baseline treatment effects (a priori independent) in a contrast-based approach is regularly preferred to the use of random baseline treatment effects (a priori dependent). That is because, often, there is not a need to model baseline treatment effects, which carry the risk of model misspecification. However, in disconnected networks, fixed baseline treatment effects do not work (unless extra assumptions are made), as there is not enough information in the data to update the prior distribution on the contrasts between disconnected treatments. In this paper, we investigate to what extent the use of random baseline treatment effects is dangerous in disconnected networks. We take 2 publicly available datasets of connected networks and disconnect them in multiple ways. We then compare the results of treatment comparisons obtained from a Bayesian contrast-based analysis of each disconnected network using random normally distributed and exchangeable baseline treatment effects to those obtained from a Bayesian contrast-based analysis of their initial connected network using fixed baseline treatment effects. For the 2 datasets considered, we found that the use of random baseline treatment effects in disconnected networks was appropriate. Because those datasets were not cherry-picked, there should be other disconnected networks that would benefit from being analyzed using random baseline treatment effects. However, there is also a risk for the normality and exchangeability assumption to be inappropriate in other datasets even though we have not observed this situation in our case study. We provide code, so other datasets can be investigated. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Can baseline serum creatinine and e-GFR predict renal function outcome after augmentation cystoplasty in children?

    Science.gov (United States)

    Singh, Prempal; Bansal, Ankur; Sekhon, Virender; Nunia, Sandeep; Ansari, M S

    2018-01-01

    To assess cut-off value of creatinine and glomerular filtration rate for augmentation cystoplasty (AC) in paediatric age-group. Data of all paediatric-patients (Creatinine and e-GFR were assessed at the time of surgery, at 6 months and at last follow-up. Renal function deterioration was defined as increase in creatinine by ≥25% from baseline value or new-onset stage-3 CKD or worsening of CKD stage with pre-operative-CKD stage-3. ROCs were plotted using creatinine and e-GFR for AC. A total of 94 patients with mean-age 8.9 years were included. The mean creatinine and e-GFR were 1.33mg/dL and 57.68mL/min respectively. Out of 94 patients, AC was performed in 45 patients and in the remaining 49 patients AC was not done (control-group), as they were not willing for the same. Baseline patient's characteristics were comparable in both Groups. 22 underwent gastro-cystoplasty (GC) and 25 underwent ileo-cystoplasty (IC). Decline in renal function was observed in 15 (33.3%) patients of AC-group and in 31 (63.3%) patients of control-group. Patients having creatinine ≥1.54mg/dL (P=0.004, sensitivity (S) 63.6% and specificity (s) 90.5%) at baseline and e-GFR ≤46mL/min (P=0.000, S=100% and s=85.7%) at the time of surgery had significantly increased probability of renal function deterioration on follow-up after AC. e-GFR ≤46mL/min and creatinine ≥1.54mg/dL at time of surgery could serve as a predictor of renal function deterioration in AC in paediatric patients. Copyright® by the International Brazilian Journal of Urology.

  11. Spent Nuclear Fuel Project technical baseline document. Fiscal year 1995: Volume 1, Baseline description

    International Nuclear Information System (INIS)

    Womack, J.C.; Cramond, R.; Paedon, R.J.

    1995-01-01

    This document is a revision to WHC-SD-SNF-SD-002, and is issued to support the individual projects that make up the Spent Nuclear Fuel Project in the lower-tier functions, requirements, interfaces, and technical baseline items. It presents results of engineering analyses since Sept. 1994. The mission of the SNFP on the Hanford site is to provide safety, economic, environmentally sound management of Hanford SNF in a manner that stages it to final disposition. This particularly involves K Basin fuel, although other SNF is involved also

  12. Sex Differences and Self-Reported Attention Problems During Baseline Concussion Testing.

    Science.gov (United States)

    Brooks, Brian L; Iverson, Grant L; Atkins, Joseph E; Zafonte, Ross; Berkner, Paul D

    2016-01-01

    Amateur athletic programs often use computerized cognitive testing as part of their concussion management programs. There is evidence that athletes with preexisting attention problems will have worse cognitive performance and more symptoms at baseline testing. The purpose of this study was to examine whether attention problems affect assessments differently for male and female athletes. Participants were drawn from a database that included 6,840 adolescents from Maine who completed Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) at baseline (primary outcome measure). The final sample included 249 boys and 100 girls with self-reported attention problems. Each participant was individually matched for sex, age, number of past concussions, and sport to a control participant (249 boys, 100 girls). Boys with attention problems had worse reaction time than boys without attention problems. Girls with attention problems had worse visual-motor speed than girls without attention problems. Boys with attention problems reported more total symptoms, including more cognitive-sensory and sleep-arousal symptoms, compared with boys without attention problems. Girls with attention problems reported more cognitive-sensory, sleep-arousal, and affective symptoms than girls without attention problems. When considering the assessment, management, and outcome from concussions in adolescent athletes, it is important to consider both sex and preinjury attention problems regarding cognitive test results and symptom reporting.

  13. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong-Xin, E-mail: hxwang@iphy.me [Department of Physics, Nanjing University, Nanjing 210093 (China); Zhan, Liang; Li, Yu-Feng; Cao, Guo-Fu [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Shen-Jian [Department of Physics, Nanjing University, Nanjing 210093 (China)

    2017-05-15

    We report the neutrino mass hierarchy (MH) determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  14. Dependence of optimum baseline setting on scatter fraction and detector response function

    International Nuclear Information System (INIS)

    Atkins, F.B.; Beck, R.N.; Hoffer, P.B.; Palmer, D.

    1977-01-01

    A theoretical and experimental investigation has been undertaken to determine the dependence of an optimum baseline setting on the amount of scattered radiation recorded in a spectrum, and on the energy resolution of the detector. In particular, baseline settings were established for clinical examinations which differed greatly in the amount of scattered radiation, namely, liver and brain scans, for which individual variations were found to produce only minimal fluctuations in the optimum baseline settings. This analysis resulted in an optimum baseline setting of 125.0 keV for brain scans and 127.2 keV for liver scans for the scintillation camera used in these studies. The criterion that was used is based on statistical considerations of the measurement of an unscattered component in the presence of a background due to scattered photons. The limitations of such a criterion are discussed, and phantom images are presented to illustrate these effects at various baseline settings. (author)

  15. A comparison of baseline methodologies for 'Reducing Emissions from Deforestation and Degradation'

    Directory of Open Access Journals (Sweden)

    Kok Kasper

    2009-07-01

    Full Text Available Abstract Background A mechanism for emission reductions from deforestation and degradation (REDD is very likely to be included in a future climate agreement. The choice of REDD baseline methodologies will crucially influence the environmental and economic effectiveness of the climate regime. We compare three different historical baseline methods and one innovative dynamic model baseline approach to appraise their applicability under a future REDD policy framework using a weighted multi-criteria analysis. Results The results show that each baseline method has its specific strengths and weaknesses. Although the dynamic model allows for the best environmental and for comparatively good economic performance, its high demand for data and technical capacity limit the current applicability in many developing countries. Conclusion The adoption of a multi-tier approach will allow countries to select the baseline method best suiting their specific capabilities and data availability while simultaneously ensuring scientific transparency, environmental effectiveness and broad political support.

  16. An Automatic Baseline Regulation in a Highly Integrated Receiver Chip for JUNO

    Science.gov (United States)

    Muralidharan, P.; Zambanini, A.; Karagounis, M.; Grewing, C.; Liebau, D.; Nielinger, D.; Robens, M.; Kruth, A.; Peters, C.; Parkalian, N.; Yegin, U.; van Waasen, S.

    2017-09-01

    This paper describes the data processing unit and an automatic baseline regulation of a highly integrated readout chip (Vulcan) for JUNO. The chip collects data continuously at 1 Gsamples/sec. The Primary data processing which is performed in the integrated circuit can aid to reduce the memory and data processing efforts in the subsequent stages. In addition, a baseline regulator compensating a shift in the baseline is described.

  17. Baseline psychophysiological and cortisol reactivity as a predictor of PTSD treatment outcome in virtual reality exposure therapy.

    Science.gov (United States)

    Norrholm, Seth Davin; Jovanovic, Tanja; Gerardi, Maryrose; Breazeale, Kathryn G; Price, Matthew; Davis, Michael; Duncan, Erica; Ressler, Kerry J; Bradley, Bekh; Rizzo, Albert; Tuerk, Peter W; Rothbaum, Barbara O

    2016-07-01

    Baseline cue-dependent physiological reactivity may serve as an objective measure of posttraumatic stress disorder (PTSD) symptoms. Additionally, prior animal model and psychological studies would suggest that subjects with greatest symptoms at baseline may have the greatest violation of expectancy to danger when undergoing exposure based psychotherapy; thus treatment approaches which enhanced the learning under these conditions would be optimal for those with maximal baseline cue-dependent reactivity. However methods to study this hypothesis objectively are lacking. Virtual reality (VR) methodologies have been successfully employed as an enhanced form of imaginal prolonged exposure therapy for the treatment of PTSD. Our goal was to examine the predictive nature of initial psychophysiological (e.g., startle, skin conductance, heart rate) and stress hormone responses (e.g., cortisol) during presentation of VR-based combat-related stimuli on PTSD treatment outcome. Combat veterans with PTSD underwent 6 weeks of VR exposure therapy combined with either d-cycloserine (DCS), alprazolam (ALP), or placebo (PBO). In the DCS group, startle response to VR scenes prior to initiation of treatment accounted for 76% of the variance in CAPS change scores, p < 0.001, in that higher responses predicted greater changes in symptom severity over time. Additionally, baseline cortisol reactivity was inversely associated with treatment response in the ALP group, p = 0.04. We propose that baseline cue-activated physiological measures will be sensitive to predicting patients' level of response to exposure therapy, in particular in the presence of enhancement (e.g., DCS). Published by Elsevier Ltd.

  18. Stability analysis of geomagnetic baseline data obtained at Cheongyang observatory in Korea

    Science.gov (United States)

    Amran, Shakirah M.; Kim, Wan-Seop; Cho, Heh Ree; Park, Po Gyu

    2017-07-01

    The stability of baselines produced by Cheongyang (CYG) observatory from the period of 2014 to 2016 is analysed. Step heights of higher than 5 nT were found in H and Z components in 2014 and 2015 due to magnetic noise in the absolute-measurement hut. In addition, a periodic modulation behaviour observed in the H and Z baseline curves was related to annual temperature variation of about 20 °C in the fluxgate magnetometer hut. Improvement in data quality was evidenced by a small dispersion between successive measurements from June 2015 to the end of 2016. Moreover, the baseline was also improved by correcting the discontinuity in the H and Z baselines.

  19. Stability analysis of geomagnetic baseline data obtained at Cheongyang observatory in Korea

    Directory of Open Access Journals (Sweden)

    S. M. Amran

    2017-07-01

    Full Text Available The stability of baselines produced by Cheongyang (CYG observatory from the period of 2014 to 2016 is analysed. Step heights of higher than 5 nT were found in H and Z components in 2014 and 2015 due to magnetic noise in the absolute-measurement hut. In addition, a periodic modulation behaviour observed in the H and Z baseline curves was related to annual temperature variation of about 20 °C in the fluxgate magnetometer hut. Improvement in data quality was evidenced by a small dispersion between successive measurements from June 2015 to the end of 2016. Moreover, the baseline was also improved by correcting the discontinuity in the H and Z baselines.

  20. Corrective action baseline report for underground storage tank 2331-U Building 9201-1

    International Nuclear Information System (INIS)

    1994-01-01

    The purpose of this report is to provide baseline geochemical and hydrogeologic data relative to corrective action for underground storage tank (UST) 2331-U at the Building 9201-1 Site. Progress in support of the Building 9201-1 Site has included monitoring well installation and baseline groundwater sampling and analysis. This document represents the baseline report for corrective action at the Building 9201-1 site and is organized into three sections. Section 1 presents introductory information relative to the site, including the regulatory initiative, site description, and progress to date. Section 2 includes the summary of additional monitoring well installation activities and the results of baseline groundwater sampling. Section 3 presents the baseline hydrogeology and planned zone of influence for groundwater remediation

  1. 77 FR 28373 - Liberty Energy (Midstates) Corp.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-24-000] Liberty Energy (Midstates) Corp.; Notice of Baseline Filing Take notice that on April 30, 2012, Liberty Energy (Midstates) Corp. submitted a baseline filing of their Statement of Operating Conditions for services provided...

  2. The California Baseline Methane Survey

    Science.gov (United States)

    Duren, R. M.; Thorpe, A. K.; Hopkins, F. M.; Rafiq, T.; Bue, B. D.; Prasad, K.; Mccubbin, I.; Miller, C. E.

    2017-12-01

    The California Baseline Methane Survey is the first systematic, statewide assessment of methane point source emissions. The objectives are to reduce uncertainty in the state's methane budget and to identify emission mitigation priorities for state and local agencies, utilities and facility owners. The project combines remote sensing of large areas with airborne imaging spectroscopy and spatially resolved bottom-up data sets to detect, quantify and attribute emissions from diverse sectors including agriculture, waste management, oil and gas production and the natural gas supply chain. Phase 1 of the project surveyed nearly 180,000 individual facilities and infrastructure components across California in 2016 - achieving completeness rates ranging from 20% to 100% per emission sector at < 5 meters spatial resolution. Additionally, intensive studies of key areas and sectors were performed to assess source persistence and variability at times scales ranging from minutes to months. Phase 2 of the project continues with additional data collection in Spring and Fall 2017. We describe the survey design and measurement, modeling and analysis methods. We present initial findings regarding the spatial, temporal and sectoral distribution of methane point source emissions in California and their estimated contribution to the state's total methane budget. We provide case-studies and lessons learned about key sectors including examples where super-emitters were identified and mitigated. We summarize challenges and recommendations for future methane research, inventories and mitigation guidance within and beyond California.

  3. Gated integrator with signal baseline subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.

    1996-12-17

    An ultrafast, high precision gated integrator includes an opamp having differential inputs. A signal to be integrated is applied to one of the differential inputs through a first input network, and a signal indicative of the DC offset component of the signal to be integrated is applied to the other of the differential inputs through a second input network. A pair of electronic switches in the first and second input networks define an integrating period when they are closed. The first and second input networks are substantially symmetrically constructed of matched components so that error components introduced by the electronic switches appear symmetrically in both input circuits and, hence, are nullified by the common mode rejection of the integrating opamp. The signal indicative of the DC offset component is provided by a sample and hold circuit actuated as the integrating period begins. The symmetrical configuration of the integrating circuit improves accuracy and speed by balancing out common mode errors, by permitting the use of high speed switching elements and high speed opamps and by permitting the use of a small integrating time constant. The sample and hold circuit substantially eliminates the error caused by the input signal baseline offset during a single integrating window. 5 figs.

  4. Gated integrator with signal baseline subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xucheng (Lisle, IL)

    1996-01-01

    An ultrafast, high precision gated integrator includes an opamp having differential inputs. A signal to be integrated is applied to one of the differential inputs through a first input network, and a signal indicative of the DC offset component of the signal to be integrated is applied to the other of the differential inputs through a second input network. A pair of electronic switches in the first and second input networks define an integrating period when they are closed. The first and second input networks are substantially symmetrically constructed of matched components so that error components introduced by the electronic switches appear symmetrically in both input circuits and, hence, are nullified by the common mode rejection of the integrating opamp. The signal indicative of the DC offset component is provided by a sample and hold circuit actuated as the integrating period begins. The symmetrical configuration of the integrating circuit improves accuracy and speed by balancing out common mode errors, by permitting the use of high speed switching elements and high speed opamps and by permitting the use of a small integrating time constant. The sample and hold circuit substantially eliminates the error caused by the input signal baseline offset during a single integrating window.

  5. Rapidly shifting baselines in Yangtze fishing communities and local memory of extinct species.

    Science.gov (United States)

    Turvey, Samuel T; Barrett, Leigh A; Yujiang, Hao; Lei, Zhang; Xinqiao, Zhang; Xianyan, Wang; Yadong, Huang; Kaiya, Zhou; Hart, Tom; Ding, Wang

    2010-06-01

    Local ecological knowledge can provide a unique source of data for conservation, especially in efforts to investigate the status of rare or possibly extinct species, but it is unlikely to remain constant over time. Loss of perspective about past ecological conditions caused by lack of communication between generations may create "shifting baseline syndrome," in which younger generations are less aware of local species diversity or abundance in the recent past. This phenomenon has been widely discussed, but has rarely been examined quantitatively. We present new evidence of shifting baselines in local perception of regional species declines and on the duration of "community memory" of extinct species on the basis of extensive interviews with fishers in communities across the middle-lower Yangtze basin. Many Yangtze species have experienced major declines in recent decades, and the Yangtze River dolphin or baiji (Lipotes vexillifer) and Yangtze paddlefish (Psephurus gladius) may have become extinct during the 21(st) century. Although informants across all age classes were strongly aware of the Yangtze ecosystem's escalating resource depletion and environmental degradation, older informants were more likely to recognize declines in two commercially important fish species, Reeves' shad (Tenualosa reevesii) and Yangtze pufferfish (Takifugu fasciatus), and to have encountered baiji and paddlefish in the past. Age was also a strong predictor of whether informants had even heard of baiji or paddlefish, with younger informants being substantially less likely to recognize either species. A marked decrease in local knowledge about the Yangtze freshwater megafauna matched the time of major population declines of these species from the 1970s onwards, and paddlefish were already unknown to over 70% of all informants below the age of 40 and to those who first started fishing after 1995. This rapid rate of cultural baseline shift suggests that once even megafaunal species cease to

  6. Determination of the Territorial Sea Baseline - Measurement Aspect

    Science.gov (United States)

    Specht, Cezary; Weintrit, Adam; Specht, Mariusz; Dabrowski, Pawel

    2017-12-01

    Determining the course of the territorial sea baseline (TSB) of the coastal state is the basis for establishing its maritime boundaries, thus becoming indirect part of maritime policy of the state. Besides the following aspects: legal and methodological as described in the conventions, acts, standards and regulations, equally important is the issue of measurement methodology with respect to the boundaries of the territorial sea. The publication discussed accuracy requirements of the TSB measurement implementation, the relationship of sea level with a choice of the method of its determination, and discussed the implementation of such a measurement on a selected example. As the test reservoir was used the 400-meter stretch of the public beach in Gdynia. During the measurements they used the GNSS geodetic receiver operating in real time based on the geodetic network - VRSnet.pl. Additionally, a comparison was made of the applied method with analogous measurements of the TSB performed in 1999.

  7. Robust extraction of baseline signal of atmospheric trace species using local regression

    Science.gov (United States)

    Ruckstuhl, A. F.; Henne, S.; Reimann, S.; Steinbacher, M.; Vollmer, M. K.; O'Doherty, S.; Buchmann, B.; Hueglin, C.

    2012-11-01

    The identification of atmospheric trace species measurements that are representative of well-mixed background air masses is required for monitoring atmospheric composition change at background sites. We present a statistical method based on robust local regression that is well suited for the selection of background measurements and the estimation of associated baseline curves. The bootstrap technique is applied to calculate the uncertainty in the resulting baseline curve. The non-parametric nature of the proposed approach makes it a very flexible data filtering method. Application to carbon monoxide (CO) measured from 1996 to 2009 at the high-alpine site Jungfraujoch (Switzerland, 3580 m a.s.l.), and to measurements of 1,1-difluoroethane (HFC-152a) from Jungfraujoch (2000 to 2009) and Mace Head (Ireland, 1995 to 2009) demonstrates the feasibility and usefulness of the proposed approach. The determined average annual change of CO at Jungfraujoch for the 1996 to 2009 period as estimated from filtered annual mean CO concentrations is -2.2 ± 1.1 ppb yr-1. For comparison, the linear trend of unfiltered CO measurements at Jungfraujoch for this time period is -2.9 ± 1.3 ppb yr-1.

  8. U-10Mo Baseline Fuel Fabrication Process Description

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Lance R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Arendt, Christina L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dye, Daniel F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clayton, Christopher K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lerchen, Megan E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lombardo, Nicholas J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zacher, Alan H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-09-27

    This document provides a description of the U.S. High Power Research Reactor (USHPRR) low-enriched uranium (LEU) fuel fabrication process. This document is intended to be used in conjunction with the baseline process flow diagram (PFD) presented in Appendix A. The baseline PFD is used to document the fabrication process, communicate gaps in technology or manufacturing capabilities, convey alternatives under consideration, and as the basis for a dynamic simulation model of the fabrication process. The simulation model allows for the assessment of production rates, costs, and manufacturing requirements (manpower, fabrication space, numbers and types of equipment, etc.) throughout the lifecycle of the USHPRR program. This document, along with the accompanying PFD, is updated regularly

  9. 75 FR 70732 - Enterprise Texas Pipeline LLC; Notice of Baseline Filing

    Science.gov (United States)

    2010-11-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-92-001] Enterprise Texas Pipeline LLC; Notice of Baseline Filing November 10, 2010. Take notice that on November 9, 2010, Enterprise Texas Pipeline LLC submitted a revised baseline filing of its Statement of Operating Conditions...

  10. System maintenance test plan for the TWRS controlled baseline database system

    International Nuclear Information System (INIS)

    Spencer, S.G.

    1998-01-01

    TWRS [Tank Waste Remediation System] Controlled Baseline Database, formally known as the Performance Measurement Control System, is used to track and monitor TWRS project management baseline information. This document contains the maintenance testing approach for software testing of the TCBD system once SCR/PRs are implemented

  11. 40 CFR 80.290 - How does a refiner apply for a sulfur baseline?

    Science.gov (United States)

    2010-07-01

    ... baseline? 80.290 Section 80.290 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (abt) Program-General Information § 80.290 How does a refiner apply for a sulfur baseline? (a) The... accordance with § 80.217. (b) The sulfur baseline request must be sent to: U.S. EPA, Attn: Sulfur Program...

  12. Baseline inventory data recommendations for National Wildlife Refuges

    Data.gov (United States)

    Department of the Interior — The Baseline Inventory Team recommends that each refuge have available abiotic “data layers” for topography, aerial photography, hydrography, soils, boundaries, and...

  13. Baseline Caesium-137 and Plutonium-239+240 inventory assessment for Central Europe

    Science.gov (United States)

    Meusburger, Katrin; Borelli, Pasquale; Evrard, Olivier; Ketterer, Michael; Mabit, Lionel; van Oost, Kristof; Alewell, Christine; Panagos, Panos

    2017-04-01

    Artificial fallout radionuclides (FRNs) such as Caesium-137 and Plutonium-239+240 released as products of the thermonuclear weapons testing that took place from the mid-1950s to the early 1980s and from nuclear power plant accidents (e.g. Chernobyl) are useful tools to quantify soil redistribution. In combination with geostatistics, FRNs may have the potential to bridge the gap between small scale process oriented studies and modelling that simplifies processes and effects over large spatial scales. An essential requirement for the application of FRNs as soil erosion tracers is the establishment of the baseline fallout at undisturbed sites before its comparison to those inventories found at sites undergoing erosion/accumulation. For this purpose, undisturbed topsoil (0-20cm) samples collected in 2009 within the framework of the Land Use/Cover Area frame Survey (LUCAS) have been measured by gamma-spectrometry and ICP-MS to determine 137Cs (n=145) and 239+240Pu (n=108) activities. To restrict the analysis to undisturbed reference sites a geospatial database query selecting only sites having a slope angle <2 degree, outside riparian zones (to avoid depositional sites) and under permanent grassland cover (according to CORINE Land Cover and Landsat) was applied. This study reports preliminary results on the feasibility of establishing a 137Cs and 239+240Pu baseline inventory map for Central Europe. The 137Cs/239+240Pu activity ratios will further allow assessing the rate and the spatial variability of 137Cs Chernobyl fallout. The establishment of such baseline inventory map will provide a unique opportunity to assess soil redistribution for a comparable time-frame (1953-2009) following a harmonised methodological protocol across national boundaries.

  14. Baseline for trust: defining 'new and additional' climate funding

    Energy Technology Data Exchange (ETDEWEB)

    Stadelmann, Martin [University of Zurich (Switzerland); Roberts, J. Timmons [Brown University (United States); Huq, Saleemul

    2010-06-15

    Climate finance is becoming a dark curve on the road from Copenhagen to Cancún. Poorer nations fear that richer ones will fulfil the US$30 billion 'fast-start' climate finance promises made in the non-binding Copenhagen Accord by relabelling or diverting basic development aid, or by simply delivering on past climate finance pledges. The problem is simple: contributor countries are operating with no clear baseline against which their promise of 'new and additional' funding can be counted – and they do not accept the baselines put forth by developing countries. A viable solution for the short term is to use projections of business-as-usual development assistance as baselines. The longer-term benchmark could be the provision of truly 'new' funds from new funding sources. Substantial up-front negotiations may be required, but seizing this opportunity to define baselines will build confidence on both sides and create predictability for future finance.

  15. Office of Civilian Radioactive Waste Management Program Cost and Schedule Baseline

    International Nuclear Information System (INIS)

    1992-09-01

    The purpose of this document is to establish quantitative expressions of proposed costs and schedule to serve as a basis for measurement of program performance. It identifies the components of the Program Cost and Schedule Baseline (PCSB) that will be subject to change control by the Executive (Level 0) and Program (Level 1) Change Control Boards (CCBS) and establishes their baseline values. This document also details PCSB reporting, monitoring, and corrective action requirements. The Program technical baseline contained in the Waste Management System Description (WMSD), the Waste Management System Requirements (WMSR), and the Physical System Requirements documents provide the technical basis for the PCSB. Changes to the PCSB will be approved by the Pregrain Change Control Board (PCCB)In addition to the PCCB, the Energy System Acquisition Advisory Board Baseline CCB (ESAAB BCCB) will perform control functions relating to Total Project Cost (TPC) and major schedule milestones for the Yucca Mountain Site Characterization Project and the Monitored Retrievable Storage (MRS) Project

  16. Quantification of in vivo 1H magnetic resonance spectroscopy signals with baseline and lineshape estimation

    International Nuclear Information System (INIS)

    Osorio-Garcia, M I; Sima, D M; Van Huffel, S; Nielsen, F U; Dresselaers, T; Himmelreich, U; Van Leuven, F

    2011-01-01

    The in vivo quantification of magnetic resonance spectroscopy (MRS) signals is a method to estimate metabolite concentrations of living tissue. Obtaining reliable concentrations is still a challenge due to the experimental conditions affecting spectral quality. Additionally, lipids and macromolecules overlap with the metabolites of interest, affecting their reliable estimation. In this study, we propose to combine the self-deconvolution lineshape estimation method, which accounts for spectral shape distortions, with two different approaches for taking into account the macromolecular baseline contribution: (a) based on macromolecules and lipids measured in vivo using an inversion recovery technique, and (b) based on the simulation of macromolecular resonances using prior knowledge from a database of inversion recovery signals. The ultimate goal is to measure macromolecular and lipid data only once as described in (a) to create macromolecular and lipid profiles. These profiles then can be used as described in (b) for data measured under the same conditions. The method is evaluated on in vivo 1 H MRS signals at 9.4 T from mouse hippocampus. Results show that better metabolite fits are obtained when lineshape and baseline estimations are simultaneously performed and that baseline estimation based on prior knowledge from macromolecular measured signals can be reliably used to replace time-consuming individual macromolecular and lipid acquisitions

  17. Predicting Baseline for Analysis of Electricity Pricing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Lee, D. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Choi, J. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Spurlock, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sim, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wu, K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-03

    To understand the impact of new pricing structure on residential electricity demands, we need a baseline model that captures every factor other than the new price. The standard baseline is a randomized control group, however, a good control group is hard to design. This motivates us to devlop data-driven approaches. We explored many techniques and designed a strategy, named LTAP, that could predict the hourly usage years ahead. The key challenge in this process is that the daily cycle of electricity demand peaks a few hours after the temperature reaching its peak. Existing methods rely on the lagged variables of recent past usages to enforce this daily cycle. These methods have trouble making predictions years ahead. LTAP avoids this trouble by assuming the daily usage profile is determined by temperature and other factors. In a comparison against a well-designed control group, LTAP is found to produce accurate predictions.

  18. CASA Uno GPS orbit and baseline experiments

    Science.gov (United States)

    Schutz, B. E.; Ho, C. S.; Abusali, P. A. M.; Tapley, B. D.

    1990-01-01

    CASA Uno data from sites distributed in longitude from Australia to Europe have been used to determine orbits of the GPS satellites. The characteristics of the orbits determined from double difference phase have been evaluated through comparisons of two-week solutions with one-week solutions and by comparisons of predicted and estimated orbits. Evidence of unmodeled effects is demonstrated, particularly associated with the orbit planes that experience solar eclipse. The orbit accuracy has been assessed through the repeatability of unconstrained estimated baseline vectors ranging from 245 km to 5400 km. Both the baseline repeatability and the comparison with independent space geodetic methods give results at the level of 1-2 parts in 100,000,000. In addition, the Mojave/Owens Valley (245 km) and Kokee Park/Ft. Davis (5409 km) estimates agree with VLBI and SLR to better than 1 part in 100,000,000.

  19. Baseline albumin is associated with worsening renal function in patients with acute decompensated heart failure receiving continuous infusion loop diuretics.

    Science.gov (United States)

    Clarke, Megan M; Dorsch, Michael P; Kim, Susie; Aaronson, Keith D; Koelling, Todd M; Bleske, Barry E

    2013-06-01

    To identify baseline predictors of worsening renal function (WRF) in an acute decompensated heart failure (ADHF) patient population receiving continuous infusion loop diuretics. Retrospective observational analysis. Academic tertiary medical center. A total of 177 patients with ADHF receiving continuous infusion loop diuretics from January 2006 through June 2009. The mean patient age was 61 years, 63% were male, ~45% were classified as New York Heart Association functional class III, and the median length of loop diuretic infusion was 4 days. Forty-eight patients (27%) developed WRF, and 34 patients (19%) died during hospitalization. Cox regression time-to-event analysis was used to determine the time to WRF based on different demographic and clinical variables. Baseline serum albumin 3 g/dl or less was the only significant predictor of WRF (hazard ratio [HR] 2.87, 95% confidence interval [CI] 1.60-5.16, p=0.0004), which remained significant despite adjustments for other covariates. Serum albumin 3 g/dl or less is a practical baseline characteristic associated with the development of WRF in patients with ADHF receiving continuous infusion loop diuretics. © 2013 Pharmacotherapy Publications, Inc.

  20. Influence of priming exercise on pulmonary O2 uptake kinetics during transitions to high-intensity exercise from an elevated baseline.

    Science.gov (United States)

    DiMenna, Fred J; Wilkerson, Daryl P; Burnley, Mark; Jones, Andrew M

    2008-08-01

    It has been suggested that the slower O2 uptake (VO2) kinetics observed when exercise is initiated from an elevated baseline metabolic rate are linked to an impairment of muscle O2 delivery. We hypothesized that "priming" exercise would significantly reduce the phase II time constant (tau) during subsequent severe-intensity cycle exercise initiated from an elevated baseline metabolic rate. Seven healthy men completed exercise transitions to 70% of the difference between gas exchange threshold (GET) and peak VO2 from a moderate-intensity baseline (90% GET) on three occasions in each of the "unprimed" and "primed" conditions. Pulmonary gas exchange, heart rate, and the electromyogram of m. vastus lateralis were measured during all tests. The phase II VO2 kinetics were slower when severe exercise was initiated from a baseline of moderate exercise compared with unloaded pedaling (mean+/-SD tau, 42+/-15 vs. 33+/-8 s; P0.05). The amplitude of the VO2 slow component and the change in electromyogram from minutes 2 to 6 were both significantly reduced following priming exercise (VO2 slow component: from 0.47+/-0.09 to 0.27+/-0.13 l/min; change in integrated electromyogram between 2 and 6 min: from 51+/-35 to 26+/-43% of baseline; Pchanges in muscle fiber activation.

  1. The "Healthy Habits, Healthy Girls" randomized controlled trial for girls: study design, protocol, and baseline results.

    Science.gov (United States)

    Leme, Ana Carolina Barco; Philippi, Sonia Tucunduva

    2015-07-01

    The purpose of this article is to describe the study design, protocol, and baseline results of the "Healthy Habits, Healthy Girls" program. The intervention is being evaluated through a randomized controlled trial in 10 public schools in the city of São Paulo, Brazil. Data on the following variables were collected and assessed at baseline and will be reevaluated at 7 and 12 months: body mass index, waist circumference, dietary intake, nutrition, physical activity, social cognitive mediators, physical activity level, sedentary behaviors, self-rated physical status, and overall self-esteem. According to the baseline results, 32.4% and 23.4% of girls were overweight in the intervention and control groups, respectively, and in both groups a higher percentage failed to meet daily recommendations for moderate and vigorous physical activity and maximum screen time (TV, computer, mobile devices). There were no significant differences between the groups for most of the variables, except age (p = 0.000) and waist circumference (p = 0.014). The study showed a gap in the Brazilian literature on protocols for randomized controlled trials to prevent obesity among youth. The current study may thus be an important initial contribution to the field.

  2. 75 FR 38802 - DCP Raptor Pipeline, LLC; Notice of Baseline Filing

    Science.gov (United States)

    2010-07-06

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-42-000] DCP Raptor Pipeline, LLC; Notice of Baseline Filing June 28, 2010. Take notice that on June 22, 2010, DCP Raptor Pipeline, LLC submitted a baseline filing of its Statement of Operating Conditions for services provided...

  3. Mass hierarchy sensitivity of medium baseline reactor neutrino experiments with multiple detectors

    Directory of Open Access Journals (Sweden)

    Hong-Xin Wang

    2017-05-01

    Full Text Available We report the neutrino mass hierarchy (MH determination of medium baseline reactor neutrino experiments with multiple detectors, where the sensitivity of measuring the MH can be significantly improved by adding a near detector. Then the impact of the baseline and target mass of the near detector on the combined MH sensitivity has been studied thoroughly. The optimal selections of the baseline and target mass of the near detector are ∼12.5 km and ∼4 kton respectively for a far detector with the target mass of 20 kton and the baseline of 52.5 km. As typical examples of future medium baseline reactor neutrino experiments, the optimal location and target mass of the near detector are selected for the specific configurations of JUNO and RENO-50. Finally, we discuss distinct effects of the reactor antineutrino energy spectrum uncertainty for setups of a single detector and double detectors, which indicate that the spectrum uncertainty can be well constrained in the presence of the near detector.

  4. Guidance on Port Biological Baseline Surveys (PBBS)

    Digital Repository Service at National Institute of Oceanography (India)

    Awad, A.; Haag, F.; Anil, A.C.; Abdulla, A.

    This publication has been prepared by GBP, IOI, CSIR-NIO and IUCN in order to serve as guidance to those who are planning to carry out a port biological baseline survey, in particular in the context of Ballast Water Management. It has been drafted...

  5. Baseline and Multimodal UAV GCS Interface Design

    Science.gov (United States)

    2013-07-01

    complete a computerized version of the NASA - TLX assessment of perceived mental workload. 2.3 Results The baseline condition ran smoothly and with...System MALE Medium-altitude, Long-endurance NASA - TLX NASA Task Load Index SA Situation Awareness TDT Tucker Davis Technologies UAV Uninhabited Aerial

  6. 48 CFR 34.202 - Integrated Baseline Reviews.

    Science.gov (United States)

    2010-10-01

    ... or contractor, and the Government, of the— (1) Ability of the project's technical plan to achieve the... successfully achieve the project schedule objectives; (3) Ability of the Performance Measurement Baseline (PMB... SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION Earned Value Management System 34.202...

  7. Correlates of time spent walking and cycling to and from work: baseline results from the commuting and health in Cambridge study

    Directory of Open Access Journals (Sweden)

    Panter Jenna

    2011-11-01

    Full Text Available Abstract Purpose Environmental perceptions and psychological measures appear to be associated with walking and cycling behaviour; however, their influence is still unclear. We assessed these associations using baseline data from a quasi-experimental cohort study of the effects of major transport infrastructural developments in Cambridge, UK. Methods Postal surveys were sent to adults who travel to work in Cambridge (n = 1582. Questions asked about travel modes and time spent travelling to and from work in the last week, perceptions of the route, psychological measures regarding car use and socio-demographic characteristics. Participants were classified into one of two categories according to time spent walking for commuting ('no walking' or 'some walking' and one of three categories for cycling ('no cycling', '1-149 min/wk' and ' ≥ 150 min/wk'. Results Of the 1164 respondents (68% female, mean (SD age: 42.3 (11.4 years 30% reported any walking and 53% reported any cycling to or from work. In multiple regression models, short distance to work and not having access to a car showed strong positive associations with both walking and cycling. Furthermore, those who reported that it was pleasant to walk were more likely to walk to or from work (OR = 4.18, 95% CI 3.02 to 5.78 and those who reported that it was convenient to cycle on the route between home and work were more likely to do so (1-149 min/wk: OR = 4.60, 95% CI 2.88 to 7.34; ≥ 150 min/wk: OR = 3.14, 95% CI 2.11 to 4.66. Positive attitudes in favour of car use were positively associated with time spent walking to or from work but negatively associated with cycling to or from work. Strong perceived behavioural control for car use was negatively associated with walking. Conclusions In this relatively affluent sample of commuters, a range of individual and household characteristics, perceptions of the route environment and psychological measures relating to car use were associated with

  8. Baseline estradiol concentration in community-dwelling Japanese American men is not associated with intra-abdominal fat accumulation over 10 years.

    Science.gov (United States)

    Kocarnik, Beverly M; Boyko, Edward J; Matsumoto, Alvin M; Fujimoto, Wilfred Y; Hayashi, Tomoshige; Leonetti, Donna L; Page, Stephanie T

    The role of plasma estradiol in the accumulation of intra-abdominal fat (IAF) in men is uncertain. Cross-sectional studies using imaging of IAF have shown either a positive or no association. In contrast, a randomised controlled trial using an aromatase inhibitor to suppress estradiol production found an association between oestrogen deficiency and short-term IAF accumulation. No longitudinal study has been conducted to examine the relationship between plasma estradiol concentration and the change in IAF area measured using direct imaging. This is a longitudinal observational study in community-dwelling Japanese-American men (n=215, mean age 52 years, BMI 25.4kg/m 2 ). IAF and subcutaneous fat areas were assessed using computerized tomography (CT) at baseline, 5 and 10 years. Baseline plasma estradiol concentrations were measured using liquid chromatography-tandem mass spectrometry. Univariate analysis found no association between baseline estradiol concentration and baseline IAF, or 5- or 10-year changes in IAF area (r=-0.05 for both time points, p=0.45 and p=0.43, respectively). Multivariate linear regression analysis of the change in IAF area by baseline estradiol concentration adjusted for age, baseline IAF area, and weight change found no association with either the 5- or 10-year IAF area change (p=0.52 and p=0.55, respectively). Plasma estradiol concentration was not associated with baseline IAF nor with change in IAF area over 5 or 10 years based on serial CT scans in community-dwelling Japanese-American men. These results do not support a role for oestrogen deficiency in IAF accumulation in men. Copyright © 2015 Asia Oceania Association for the Study of Obesity. All rights reserved.

  9. Item response theory analysis of the mechanics baseline test

    Science.gov (United States)

    Cardamone, Caroline N.; Abbott, Jonathan E.; Rayyan, Saif; Seaton, Daniel T.; Pawl, Andrew; Pritchard, David E.

    2012-02-01

    Item response theory is useful in both the development and evaluation of assessments and in computing standardized measures of student performance. In item response theory, individual parameters (difficulty, discrimination) for each item or question are fit by item response models. These parameters provide a means for evaluating a test and offer a better measure of student skill than a raw test score, because each skill calculation considers not only the number of questions answered correctly, but the individual properties of all questions answered. Here, we present the results from an analysis of the Mechanics Baseline Test given at MIT during 2005-2010. Using the item parameters, we identify questions on the Mechanics Baseline Test that are not effective in discriminating between MIT students of different abilities. We show that a limited subset of the highest quality questions on the Mechanics Baseline Test returns accurate measures of student skill. We compare student skills as determined by item response theory to the more traditional measurement of the raw score and show that a comparable measure of learning gain can be computed.

  10. Information Technology Sector Baseline Risk Assessment

    Science.gov (United States)

    2009-08-01

    alternative root be economically advantageous , an actor’s ability to exploit market forces and create an alternative root would be significantly improved...conduct their operations. Therefore, a loss or disruption to Internet services would not be advantageous for the desired outcomes of these syndicates.26... eCommerce Service loss or disruption [C] Traffic Redirection [C] = Undesired consequence Information Technology Sector Baseline Risk Assessment

  11. The prognostic utility of baseline alpha-fetoprotein for hepatocellular carcinoma patients.

    Science.gov (United States)

    Silva, Jack P; Gorman, Richard A; Berger, Nicholas G; Tsai, Susan; Christians, Kathleen K; Clarke, Callisia N; Mogal, Harveshp; Gamblin, T Clark

    2017-12-01

    Alpha-fetoprotein (AFP) has a valuable role in postoperative surveillance for hepatocellular carcinoma (HCC) recurrence. The utility of pretreatment or baseline AFP remains controversial. The present study hypothesized that elevated baseline AFP levels are associated with worse overall survival in HCC patients. Adult HCC patients were identified using the National Cancer Database (2004-2013). Patients were stratified according to baseline AFP measurements into the following groups: Negative (2000). The primary outcome was overall survival (OS), which was analyzed by log-rank test and graphed using Kaplan-Meier method. Multivariate regression modeling was used to determine hazard ratios (HR) for OS. Of 41 107 patients identified, 15 809 (33.6%) were Negative. Median overall survival was highest in the Negative group, followed by Borderline, Elevated, and Highly Elevated (28.7 vs 18.9 vs 8.8 vs 3.2 months; P < 0.001). On multivariate analysis, overall survival hazard ratios for the Borderline, Elevated, and Highly Elevated groups were 1.18 (P = 0.267), 1.94 (P < 0.001), and 1.77 (P = 0.007), respectively (reference Negative). Baseline AFP independently predicted overall survival in HCC patients regardless of treatment plan. A baseline AFP value is a simple and effective method to assist in expected survival for HCC patients. © 2017 Wiley Periodicals, Inc.

  12. Effect of computer game playing on baseline laparoscopic simulator skills.

    Science.gov (United States)

    Halvorsen, Fredrik H; Cvancarova, Milada; Fosse, Erik; Mjåland, Odd

    2013-08-01

    Studies examining the possible association between computer game playing and laparoscopic performance in general have yielded conflicting results and neither has a relationship between computer game playing and baseline performance on laparoscopic simulators been established. The aim of this study was to examine the possible association between previous and present computer game playing and baseline performance on a virtual reality laparoscopic performance in a sample of potential future medical students. The participating students completed a questionnaire covering the weekly amount and type of computer game playing activity during the previous year and 3 years ago. They then performed 2 repetitions of 2 tasks ("gallbladder dissection" and "traverse tube") on a virtual reality laparoscopic simulator. Performance on the simulator were then analyzed for association to their computer game experience. Local high school, Norway. Forty-eight students from 2 high school classes volunteered to participate in the study. No association between prior and present computer game playing and baseline performance was found. The results were similar both for prior and present action game playing and prior and present computer game playing in general. Our results indicate that prior and present computer game playing may not affect baseline performance in a virtual reality simulator.

  13. Investigating the baselines of Bismuth, Optical Fiber and LED calibrated photomultiplier tubes

    CERN Document Server

    Evans, Hywel Turner

    2016-01-01

    LUCID is a detector that is the luminosity monitor for the ATLAS experiment, and its aim is to determine luminosity with an uncertainty of a few percent. The main purpose of this work is the study of the baseline stability of the LUCID readout channels during calibration runs. This study represents the first systematic approach of this problem performed by the LUCID group. By replacing the mean baseline with the minimum baseline of each event, an upper limit of 2.85% was placed upon possible improvement in determining the LED amplitude. It is therefore better to use a fixed baseline for LED, as pollution has been observed when calculating event by event. For Bismuth and Fiber, the improvement cannot be more than the gain stability of 1%, therefore the existing method is verified as optimal.

  14. Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis.

    Science.gov (United States)

    McDonald, Elizabeth S; McCarthy, Anne Marie; Akhtar, Amana L; Synnestvedt, Marie B; Schnall, Mitchell; Conant, Emily F

    2015-11-01

    Baseline mammography studies have significantly higher recall rates than mammography studies with available comparison examinations. Digital breast tomosynthesis reduces recalls when compared with digital mammographic screening alone, but many sites operate in a hybrid environment. To maximize the effect of screening digital breast tomosynthesis with limited resources, choosing which patient populations will benefit most is critical. This study evaluates digital breast tomosynthesis in the baseline screening population. Outcomes were compared for 10,728 women who underwent digital mammography screening, including 1204 (11.2%) baseline studies, and 15,571 women who underwent digital breast tomosynthesis screening, including 1859 (11.9%) baseline studies. Recall rates, cancer detection rates, and positive predictive values were calculated. Logistic regression estimated the odds ratios of recall for digital mammography versus digital breast tomosynthesis for patients undergoing baseline screening and previously screened patients, adjusted for age, race, and breast density. In the baseline subgroup, recall rates for digital mammography and digital breast tomosynthesis screening were 20.5% and 16.0%, respectively (p = 0.002); digital breast tomosynthesis screening in the baseline subgroup resulted in a 22% reduction in recall compared with digital mammography, or 45 fewer patients recalled per 1000 patients screened. Digital breast tomosynthesis screening in the previously screened patients resulted in recall reduction of 14.3% (p tomosynthesis than from digital mammography alone.

  15. Comparison of CFD Predictions of the TCA Baseline

    Science.gov (United States)

    Cappuccio, Gelsomina

    1999-01-01

    The computational fluid dynamics (CFD) comparisons being presented are compared to each other and to wind tunnel (WT) data on the baseline TCA. Some of the CFD computations were done prior to the tests and others later. Only force data (CL vs CD) from CFD will be presented as part of this report. The WT data presented comes from the testing of the baseline TCA in the Langley Unitary Plan Wind Tunnel (UPWT), Test Section #2. There are 2 sets of wind tunnel data being presented: one from test 1671 of model 2a (flapped wing) and the other from test 1679 of model 2b (solid wing). Most of the plots show only one run from each of the WT tests per configuration. But many repeat runs were taken during the tests. The WT repeat runs showed an uncertainty in the drag of +/- 0.5 count. There were times when the uncertainty in drag was better, +/- 0.25 count. Test 1671 data was of forces and pressures measured from model 2a. The wing had cutouts for installing various leading and trailing edge flaps at lower Mach numbers. The internal duct of the nacelles are not designed and fabricated as defined in the outer mold lines (OML) iges file. The internal duct was fabricated such that a linear transition occurs from the inlet to exhaust. Whereas, the iges definition has a constant area internal duct that quickly transitions from the inlet to exhaust cross sectional shape. The nacelle internal duct was fabricated, the way described, to save time and money. The variation in the cross sectional area is less than 1% from the iges definition. The nacelles were also installed with and without fairings. Fairings are defined as the build up of the nacelles on the upper wing surface so that the nacelles poke through the upper surface as defined in the OML iges file. Test 1679 data was of forces measured from model 2a and 2b. The wing for model 2b was a solid wing. The nacelles were built the same way as for model 2a, except for the nacelle base pressure installation. The nacelles were only

  16. Functional Testing Protocols for Commercial Building Efficiency Baseline Modeling Software

    Energy Technology Data Exchange (ETDEWEB)

    Jump, David; Price, Phillip N.; Granderson, Jessica; Sohn, Michael

    2013-09-06

    This document describes procedures for testing and validating proprietary baseline energy modeling software accuracy in predicting energy use over the period of interest, such as a month or a year. The procedures are designed according to the methodology used for public domain baselining software in another LBNL report that was (like the present report) prepared for Pacific Gas and Electric Company: ?Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing Protocols? (referred to here as the ?Model Analysis Report?). The test procedure focuses on the quality of the software?s predictions rather than on the specific algorithms used to predict energy use. In this way the software vendor is not required to divulge or share proprietary information about how their software works, while enabling stakeholders to assess its performance.

  17. Is CP violation observable in long baseline neutrino oscillation experiments?

    International Nuclear Information System (INIS)

    Tanimoto, M.

    1997-01-01

    We have studied CP violation originating from the phase of the neutrino-mixing matrix in the long baseline neutrino oscillation experiments. The direct measurement of CP violation is the difference of the transition probabilities between CP-conjugate channels. In those experiments, the CP-violating effect is not suppressed if the highest neutrino mass scale is taken to be 1 endash 5 eV, which is appropriate for the cosmological hot dark matter. Assuming the hierarchy for the neutrino masses, the upper bounds of CP violation have been calculated for three cases, in which mixings are constrained by the recent short baseline ones. The calculated upper bounds are larger than 10 -2 , which will be observable in the long baseline accelerator experiments. The matter effect, which is not CP invariant, has been also estimated in those experiments. copyright 1997 The American Physical Society

  18. Integrated Baseline Review (IBR) Handbook

    Science.gov (United States)

    Fleming, Jon F.; Terrell, Stefanie M.

    2018-01-01

    The purpose of this handbook is intended to be a how-to guide to prepare for, conduct, and close-out an Integrated Baseline Review (IBR). It discusses the steps that should be considered, describes roles and responsibilities, tips for tailoring the IBR based on risk, cost, and need for management insight, and provides lessons learned from past IBRs. Appendices contain example documentation typically used in connection with an IBR. Note that these appendices are examples only, and should be tailored to meet the needs of individual projects and contracts.

  19. Environmental Baseline File National Transportation

    International Nuclear Information System (INIS)

    Harris, M.

    1999-01-01

    This Environmental Baseline File summarizes and consolidates information related to the national-level transportation of commercial spent nuclear fuel. Topics addressed include: shipments of commercial spent nuclear fuel based on mostly truck and mostly rail shipping scenarios; transportation routing for commercial spent nuclear fuel sites and DOE sites; radionuclide inventories for various shipping container capacities; transportation routing; populations along transportation routes; urbanized area population densities; the impacts of historical, reasonably foreseeable, and general transportation; state-level food transfer factors; Federal Guidance Report No. 11 and 12 radionuclide dose conversion factors; and national average atmospheric conditions

  20. Wind power projects in the CDM: Methodologies and tools for baselines, carbon financing and substainability analysis[CDM=Clean Development Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Ringius, L.; Grohnheit, P.E.; Nielsen, L.H.; Olivier, A.L.; Painuly, J.; Villavicencio, A.

    2002-12-01

    power production profile of Zafarana, the emission rates estimated by runs with 1 hour time-steps of the simulation tool ES3 range from 0.590 tCO{sub 2}/MWh to 0.610 tCO{sub 2}/MWh. These results come very close to estimates based on two different interpretations of standardized baseline options above. (au)

  1. The optimized baseline project: Reinventing environmental restoration at Hanford

    International Nuclear Information System (INIS)

    Goodenough, J.D.; Janaskie, M.T.; Kleinen, P.J.

    1994-01-01

    The U.S. Department of Energy Richland Operations Office (DOE-RL) is using a strategic planning effort (termed the Optimized Baseline Project) to develop a new approach to the Hanford Environmental Restoration program. This effort seeks to achieve a quantum leap improvement in performance through results oriented prioritization of activities. This effort was conducted in parallel with the renegotiation of the Tri-Party Agreement and provided DOE with an opportunity to propose innovative initiatives to promote cost effectiveness, accelerate progress in the Hanford Environmental Restoration Program and involve stakeholders in the decision-making process. The Optimized Baseline project is an innovative approach to program planning and decision-making in several respects. First, the process is a top down, value driven effort that responds to values held by DOE, the regulatory community and the public. Second, planning is conducted in a way that reinforces the technical management process at Richland, involves the regulatory community in substantive decisions, and includes the public. Third, the Optimized Baseline Project is being conducted as part of a sitewide Hanford initiative to reinvent Government. The planning process used for the Optimized Baseline Project has many potential applications at other sites and in other programs where there is a need to build consensus among diverse, independent groups of stakeholders and decisionmakers. The project has successfully developed and demonstrated an innovative approach to program planning that accelerates the pace of cleanup, involves the regulators as partners with DOE in priority setting, and builds public understanding and support for the program through meaningful opportunities for involvement

  2. Carbon intensity of electricity generation and CDM baseline: case studies of three Chinese provinces

    International Nuclear Information System (INIS)

    Zhang Chi; Heller, T.C.; May, M.M.

    2005-01-01

    A difficult and persistent issue in the discussion of Clean Development Mechanism is estimating a carbon emissions baseline, against which tradable permits may be certified. This paper examines the proposition of adopting sectoral, as opposed to project level, baselines by conducting case studies of the electricity industry in three Chinese provinces. We find that complicated central planning, financial and institutional factors have been behind the declining trend of carbon intensity in electricity generation and its provincial variations. Government planned electricity development which incorporates many of these factors and the associated industry carbon intensity may serve as a second best baseline. However, the limitation of the baseline we examine in this study plus difficulties numerous studies have revealed in baseline setting suggests that using baselines based on counterfactuals of what would happen will in the end either miss good emission reduction opportunities, or compromise the integrity of the regime

  3. Toward Baseline Software Anomalies in NASA Missions

    Science.gov (United States)

    Layman, Lucas; Zelkowitz, Marvin; Basili, Victor; Nikora, Allen P.

    2012-01-01

    In this fast abstract, we provide preliminary findings an analysis of 14,500 spacecraft anomalies from unmanned NASA missions. We provide some baselines for the distributions of software vs. non-software anomalies in spaceflight systems, the risk ratings of software anomalies, and the corrective actions associated with software anomalies.

  4. Detecting CP violation in a single neutrino oscillation channel at very long baselines

    International Nuclear Information System (INIS)

    Latimer, D. C.; Escamilla, J.; Ernst, D. J.

    2007-01-01

    We propose a way of detecting CP violation in a single neutrino oscillation channel at very long baselines (on the order of several thousands of kilometers), given precise knowledge of the smallest mass-squared difference. It is shown that CP violation can be characterized by a shift in L/E of the peak oscillation in the ν e -ν μ appearance channel, both in vacuum and in matter. In fact, matter effects enhance the shift at a fixed energy. We consider the case in which sub-GeV neutrinos are measured with varying baseline and also the case of a fixed baseline. For the varied baseline, accurate knowledge of the absolute neutrino flux would not be necessary; however, neutrinos must be distinguishable from antineutrinos. For the fixed baseline, it is shown that CP violation can be distinguished if the mixing angle θ 13 were known

  5. Baseline Goblet Cell Mucin Secretion in the Airways Exceeds Stimulated Secretion over Extended Time Periods, and Is Sensitive to Shear Stress and Intracellular Mucin Stores.

    Directory of Open Access Journals (Sweden)

    Yunxiang Zhu

    Full Text Available Airway mucin secretion studies have focused on goblet cell responses to exogenous agonists almost to the exclusion of baseline mucin secretion (BLMS. In human bronchial epithelial cell cultures (HBECCs, maximal agonist-stimulated secretion exceeds baseline by ~3-fold as measured over hour-long periods, but mucin stores are discharged completely and require 24 h for full restoration. Hence, over 24 h, total baseline exceeds agonist-induced secretion by several-fold. Studies with HBECCs and mouse tracheas showed that BLMS is highly sensitive to mechanical stresses. Harvesting three consecutive 1 h baseline luminal incubations with HBECCs yielded equal rates of BLMS; however, lengthening the middle period to 72 h decreased the respective rate significantly, suggesting a stimulation of BLMS by the gentle washes of HBECC luminal surfaces. BLMS declined exponentially after washing HBECCs (t1/2 = 2.75 h, to rates approaching zero. HBECCs exposed to low perfusion rates exhibited spike-like increases in BLMS when flow was jumped 5-fold: BLMS increased >4 fold, then decreased within 5 min to a stable plateau at 1.5-2-fold over control. Higher flow jumps induced proportionally higher BLMS increases. Inducing mucous hyperplasia in HBECCs increased mucin production, BLMS and agonist-induced secretion. Mouse tracheal BLMS was ~6-fold higher during perfusion, than when flow was stopped. Munc13-2 null mouse tracheas, with their defect of accumulated cellular mucins, exhibited similar BLMS as WT, contrary to predictions of lower values. Graded mucous metaplasia induced in WT and Munc13-2 null tracheas with IL-13, caused proportional increases in BLMS, suggesting that naïve Munc13-2 mouse BLMS is elevated by increased mucin stores. We conclude that BLMS is, [i] a major component of mucin secretion in the lung, [ii] sustained by the mechanical activity of a dynamic lung, [iii] proportional to levels of mucin stores, and [iv] regulated differentially from agonist

  6. Baseline Goblet Cell Mucin Secretion in the Airways Exceeds Stimulated Secretion over Extended Time Periods, and Is Sensitive to Shear Stress and Intracellular Mucin Stores

    Science.gov (United States)

    Doyle, Sean P.; Nguyen, Kristine; Ribeiro, Carla M. P.; Vasquez, Paula A.; Forest, M. Gregory; Lethem, Michael I.; Dickey, Burton F.; Davis, C. William

    2015-01-01

    Airway mucin secretion studies have focused on goblet cell responses to exogenous agonists almost to the exclusion of baseline mucin secretion (BLMS). In human bronchial epithelial cell cultures (HBECCs), maximal agonist-stimulated secretion exceeds baseline by ~3-fold as measured over hour-long periods, but mucin stores are discharged completely and require 24 h for full restoration. Hence, over 24 h, total baseline exceeds agonist-induced secretion by several-fold. Studies with HBECCs and mouse tracheas showed that BLMS is highly sensitive to mechanical stresses. Harvesting three consecutive 1 h baseline luminal incubations with HBECCs yielded equal rates of BLMS; however, lengthening the middle period to 72 h decreased the respective rate significantly, suggesting a stimulation of BLMS by the gentle washes of HBECC luminal surfaces. BLMS declined exponentially after washing HBECCs (t1/2 = 2.75 h), to rates approaching zero. HBECCs exposed to low perfusion rates exhibited spike-like increases in BLMS when flow was jumped 5-fold: BLMS increased >4 fold, then decreased within 5 min to a stable plateau at 1.5–2-fold over control. Higher flow jumps induced proportionally higher BLMS increases. Inducing mucous hyperplasia in HBECCs increased mucin production, BLMS and agonist-induced secretion. Mouse tracheal BLMS was ~6-fold higher during perfusion, than when flow was stopped. Munc13-2 null mouse tracheas, with their defect of accumulated cellular mucins, exhibited similar BLMS as WT, contrary to predictions of lower values. Graded mucous metaplasia induced in WT and Munc13-2 null tracheas with IL-13, caused proportional increases in BLMS, suggesting that naïve Munc13-2 mouse BLMS is elevated by increased mucin stores. We conclude that BLMS is, [i] a major component of mucin secretion in the lung, [ii] sustained by the mechanical activity of a dynamic lung, [iii] proportional to levels of mucin stores, and [iv] regulated differentially from agonist-induced mucin

  7. Pipeline integrity: ILI baseline data for QRA

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Todd R. [Tuboscope Pipeline Services, Houston, TX (United States)]. E-mail: tporter@varco.com; Silva, Jose Augusto Pereira da [Pipeway Engenharia, Rio de Janeiro, RJ (Brazil)]. E-mail: guto@pipeway.com; Marr, James [MARR and Associates, Calgary, AB (Canada)]. E-mail: jmarr@marr-associates.com

    2003-07-01

    The initial phase of a pipeline integrity management program (IMP) is conducting a baseline assessment of the pipeline system and segments as part of Quantitative Risk Assessment (QRA). This gives the operator's integrity team the opportunity to identify critical areas and deficiencies in the protection, maintenance, and mitigation strategies. As a part of data gathering and integration of a wide variety of sources, in-line inspection (ILI) data is a key element. In order to move forward in the integrity program development and execution, the baseline geometry of the pipeline must be determined with accuracy and confidence. From this, all subsequent analysis and conclusions will be derived. Tuboscope Pipeline Services (TPS), in conjunction with Pipeway Engenharia of Brazil, operate ILI inertial navigation system (INS) and Caliper geometry tools, to address this integrity requirement. This INS and Caliper ILI tool data provides pipeline trajectory at centimeter level resolution and sub-metre 3D position accuracy along with internal geometry - ovality, dents, misalignment, and wrinkle/buckle characterization. Global strain can be derived from precise INS curvature measurements and departure from the initial pipeline state. Accurate pipeline elevation profile data is essential in the identification of sag/over bend sections for fluid dynamic and hydrostatic calculations. This data, along with pipeline construction, operations, direct assessment and maintenance data is integrated in LinaViewPRO{sup TM}, a pipeline data management system for decision support functions, and subsequent QRA operations. This technology provides the baseline for an informed, accurate and confident integrity management program. This paper/presentation will detail these aspects of an effective IMP, and experience will be presented, showing the benefits for liquid and gas pipeline systems. (author)

  8. Capabilities of long-baseline experiments in the presence of a sterile neutrino

    International Nuclear Information System (INIS)

    Dutta, Debajyoti; Gandhi, Raj; Kayser, Boris; Masud, Mehedi; Prakash, Suprabh

    2016-01-01

    Assuming that there is a sterile neutrino, we ask what then is the ability of long-baseline experiments to i) establish that neutrino oscillation violates CP, ii) determine the three-neutrino mass ordering, and iii) determine which CP-violating phase or phases are the cause of any CP violation that may be observed. We find that the ability to establish CP violation and to determine the mass ordering could be very substantial. However, the effects of the sterile neutrino could be quite large, and it might prove very difficult to determine which phase is responsible for an observed CP violation. We explain why a sterile neutrino changes the long-baseline sensitivities to CP violation and to the mass ordering in the ways that it does. We note that long-baseline experiments can probe the presence of sterile neutrinos in a way that is different from, and complementary to, the probes of short-baseline experiments. We explore the question of how large sterile-active mixing angles need to be before long-baseline experiments can detect their effects, or how small they need to be before the interpretation of these experiments can safely disregard the possible existence of sterile neutrinos.

  9. Baseline recommendations for greenhouse gas mitigation projects in the electric power sector

    Energy Technology Data Exchange (ETDEWEB)

    Kartha, Sivan; Lazarus, Michael [Stockholm Environment Institute/Tellus Institute, Boston, MA (United States); Bosi, Martina [International Energy Agency, Paris, 75 (France)

    2004-03-01

    The success of the Clean Development Mechanism (CDM) and other credit-based emission trading regimes depends on effective methodologies for quantifying a project's emissions reductions. The key methodological challenge lies in estimating project's counterfactual emission baseline, through balancing the need for accuracy, transparency, and practicality. Baseline standardisation (e.g. methodology, parameters and/or emission rate) can be a means to achieve these goals. This paper compares specific options for developing standardised baselines for the electricity sector - a natural starting point for baseline standardisation given the magnitude of the emissions reductions opportunities. The authors review fundamental assumptions that baseline studies have made with respect to estimating the generation sources avoided by CDM or other emission-reducing projects. Typically, studies have assumed that such projects affect either the operation of existing power plants (the operating margin) or the construction of new generation facilities (the build margin). The authors show that both effects are important to consider and thus recommend a combined margin approach for most projects, based on grid-specific data. They propose a three-category framework, according to projects' relative scale and environmental risk. (Author)

  10. Scientific Opportunities with the Long-Baseline Neutrino Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Adams, C.; et al.

    2013-07-28

    In this document, we describe the wealth of science opportunities and capabilities of LBNE, the Long-Baseline Neutrino Experiment. LBNE has been developed to provide a unique and compelling program for the exploration of key questions at the forefront of particle physics. Chief among the discovery opportunities are observation of CP symmetry violation in neutrino mixing, resolution of the neutrino mass hierarchy, determination of maximal or near-maximal mixing in neutrinos, searches for nucleon decay signatures, and detailed studies of neutrino bursts from galactic supernovae. To fulfill these and other goals as a world-class facility, LBNE is conceived around four central components: (1) a new, intense wide-band neutrino source at Fermilab, (2) a fine-grained `near' neutrino detector just downstream of the source, (3) the Sanford Underground Research Facility (SURF) in Lead, South Dakota at an optimal distance (~1300 km) from the neutrino source, and (4) a massive liquid argon time-projection chamber (LArTPC) deployed there as a 'far' detector. The facilities envisioned are expected to enable many other science opportunities due to the high event rates and excellent detector resolution from beam neutrinos in the near detector and atmospheric neutrinos in the far detector. This is a mature, well developed, world class experiment whose relevance, importance, and probability of unearthing critical and exciting physics has increased with time.

  11. Study on judgement baseline for XRF on-line detection system

    International Nuclear Information System (INIS)

    Zhang Quanshi; Bao Min

    2000-01-01

    Based on the Signal Detection Theory (SDT) and the statistics principle, the choice method of judgement baseline was studied. According to the characteristics of X-ray Fluorescence (XRF) spectra in the on-line detection system, the calculation methods for the characteristic peak of the element-tagged and background were carried out. The complex judgement baseline were rationally selected after a lot of experiments and analyzing. The operating results of near one year show that it is available

  12. SU-G-BRA-16: Target Dose Comparison for Dynamic MLC Tracking and Mid- Ventilation Planning in Lung Radiotherapy Subject to Intrafractional Baseline Drifts

    Energy Technology Data Exchange (ETDEWEB)

    Menten, MJ; Fast, MF; Nill, S; Oelfke, U [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London (United Kingdom)

    2016-06-15

    Purpose: Lung tumor motion during radiotherapy can be accounted for by expanded treatment margins, for example using a mid-ventilation planning approach, or by localizing the tumor in real-time and adapting the treatment beam with multileaf collimator (MLC) tracking. This study evaluates the effect of intrafractional changes in the average tumor position (baseline drifts) on these two treatment techniques. Methods: Lung stereotactic treatment plans (9-beam IMRT, 54Gy/3 fractions, mean treatment time: 9.63min) were generated for three patients: either for delivery with MLC tracking (isotropic GTV-to-PTV margin: 2.6mm) or planned with a mid-ventilation approach and delivered without online motion compensation (GTV-to-PTV margin: 4.4-6.3mm). Delivery to a breathing patient was simulated using DynaTrack, our in-house tracking and delivery software. Baseline drifts in cranial and posterior direction were simulated at a rate of 0.5, 1.0 or 1.5mm/min. For dose reconstruction, the corresponding 4DCT phase was selected for each time point of the delivery. Baseline drifts were accounted for by rigidly shifting the CT to ensure correct relative beam-to-target positioning. Afterwards, the doses delivered to each 4DCT phase were accumulated deformably on the mid-ventilation phase using research RayStation v4.6 and dose coverage of the GTV was evaluated. Results: When using the mid-ventilation planning approach, dose coverage of the tumor deteriorated substantially in the presence of baseline drifts. The reduction in D98% coverage of the GTV in a single fraction ranged from 0.4-1.2, 0.6-3.3 and 4.5-6.2Gy, respectively, for the different drift rates. With MLC tracking the GTV D98% coverage remained unchanged (+/− 0.1Gy) regardless of drift. Conclusion: Intrafractional baseline drifts reduce the tumor dose in treatments based on mid-ventilation planning. In rare, large target baseline drifts tumor dose coverage may drop below the prescription, potentially affecting clinical

  13. Logistic regression function for detection of suspicious performance during baseline evaluations using concussion vital signs.

    Science.gov (United States)

    Hill, Benjamin David; Womble, Melissa N; Rohling, Martin L

    2015-01-01

    This study utilized logistic regression to determine whether performance patterns on Concussion Vital Signs (CVS) could differentiate known groups with either genuine or feigned performance. For the embedded measure development group (n = 174), clinical patients and undergraduate students categorized as feigning obtained significantly lower scores on the overall test battery mean for the CVS, Shipley-2 composite score, and California Verbal Learning Test-Second Edition subtests than did genuinely performing individuals. The final full model of 3 predictor variables (Verbal Memory immediate hits, Verbal Memory immediate correct passes, and Stroop Test complex reaction time correct) was significant and correctly classified individuals in their known group 83% of the time (sensitivity = .65; specificity = .97) in a mixed sample of young-adult clinical cases and simulators. The CVS logistic regression function was applied to a separate undergraduate college group (n = 378) that was asked to perform genuinely and identified 5% as having possibly feigned performance indicating a low false-positive rate. The failure rate was 11% and 16% at baseline cognitive testing in samples of high school and college athletes, respectively. These findings have particular relevance given the increasing use of computerized test batteries for baseline cognitive testing and return-to-play decisions after concussion.

  14. Scheme for generating and transporting THz radiation to the X-ray experimental floor at LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-08-15

    This paper describes a novel scheme for integrating a coherent THz source in the baseline of the LCLS facility. Any method relying on the spent electron beam downstream of the baseline undulator should provide a way of transporting the radiation up to the experimental floor.Herewe propose to use the dump area access maze. In this way the THz output must propagate with limited size at least for one hundred meters in a maze, following many turns, to reach the near experimental hall. The use of a standard, discrete, open beam-waveguide formed by periodic reflectors, that is a mirror guide, would lead to unacceptable size of the system. To avoid these problems, in this paper we propose an alternative approach based on periodically spaced metallic screens with holes. This quasi-optical transmission line is referred to as an iris line. We present complete calculations for the iris line using both analytical and numerical methods, which we find in good agreement. We present a design of a THz edge radiation source based on the use of an iris line. The proposed setup takes almost no cost nor time to be implemented at the LCLS baseline, and can be used at other facilities as well. The edge radiation source is limited in maximally achievable field strength at the sample. An extension based on the use of an undulator in the presence of the iris line, which is feasible at the LCLS energies, is proposed as a possible upgrade of the baseline THz source. (orig)

  15. Scheme for generating and transporting THz radiation to the X-ray experimental floor at LCLS baseline

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-08-01

    This paper describes a novel scheme for integrating a coherent THz source in the baseline of the LCLS facility. Any method relying on the spent electron beam downstream of the baseline undulator should provide a way of transporting the radiation up to the experimental floor.Herewe propose to use the dump area access maze. In this way the THz output must propagate with limited size at least for one hundred meters in a maze, following many turns, to reach the near experimental hall. The use of a standard, discrete, open beam-waveguide formed by periodic reflectors, that is a mirror guide, would lead to unacceptable size of the system. To avoid these problems, in this paper we propose an alternative approach based on periodically spaced metallic screens with holes. This quasi-optical transmission line is referred to as an iris line. We present complete calculations for the iris line using both analytical and numerical methods, which we find in good agreement. We present a design of a THz edge radiation source based on the use of an iris line. The proposed setup takes almost no cost nor time to be implemented at the LCLS baseline, and can be used at other facilities as well. The edge radiation source is limited in maximally achievable field strength at the sample. An extension based on the use of an undulator in the presence of the iris line, which is feasible at the LCLS energies, is proposed as a possible upgrade of the baseline THz source. (orig)

  16. Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Boring, Ronald L.; Joe, Jeffrey C.

    2015-02-01

    For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

  17. Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Joe, Jeffrey C.

    2015-01-01

    For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative–intended to catalog final products–rather than formative–intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.

  18. Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE): Conceptual Design Report. Volume 1: The LBNF and DUNE Projects

    Energy Technology Data Exchange (ETDEWEB)

    Acciarri, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); et al.

    2016-01-22

    This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modular liquid argon time-projection chamber (LArTPC) located deep underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE will also have a high-resolution and high-precision near detector.

  19. Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 1: The LBNF and DUNE Projects

    CERN Document Server

    Acciarri, R.; Adamowski, M.; Adams, C.; Adamson, P.; Adhikari, S.; Ahmad, Z.; Albright, C.H.; Alion, T.; Amador, E.; Anderson, J.; Anderson, K.; Andreopoulos, C.; Andrews, M.; Andrews, R.; Anghel, I.; Anjos, J. d.; Ankowski, A.; Antonello, M.; Aranda Fernandez, A.; Ariga, A.; Ariga, T.; Aristizabal, D.; Arrieta-Diaz, E.; Aryal, K.; Asaadi, J.; Asner, D.; Athar, M.S.; Auger, M.; Aurisano, A.; Aushev, V.; Autiero, D.; Avila, M.; Back, J.J.; Bai, X.; Baibussinov, B.; Baird, M.; Balantekin, B.; Baller, B.; Ballett, P.; Bambah, B.; Bansal, M.; Bansal, S.; Barker, G.J.; Barletta, W.A.; Barr, G.; Barros, N.; Bartosz, B.; Bartoszek, L.; Bashyal, A.; Bass, M.; Bay, F.; Beacom, J.; Behera, B.R.; Bellettini, G.; Bellini, V.; Beltramello, O.; Benekos, N.; Benetti, P.A.; Bercellie, A.; Bergevin, M.; Berman, E.; Berns, H.; Bernstein, R.; Bertolucci, S.; Bhandari, B.; Bhatnagar, V.; Bhuyan, B.; Bian, J.; Biery, K.; Bishai, M.; Blackburn, T.; Blake, A.; Blaszczyk, F. d. M.; Blaufuss, E.; Bleakley, B.; Blucher, E.; Bocean, V.; Boffelli, F.; Boissevain, J.; Bolognesi, S.; Bolton, T.; Bonesini, M.; Boone, T.; Booth, C.; Bordoni, S.; Borysova, M.; Bourguille, B.; Boyd, S.B.; Brailsford, D.; Brandt, A.; Bremer, J.; Brice, S.; Bromberg, C.; Brooijmans, G.; Brown, G.; Brown, R.; Brunetti, G.; Bu, X.; Buchanan, N.; Budd, H.; Bugg, B.; Calafiura, P.; Calligarich, E.; Calvo, E.; Camilleri, L.; Campanelli, M.; Cantini, C.; Carls, B.; Carr, R.; Cascella, M.; Castromonte, C.; Mur, E.Catano; Cavanna, F.; Centro, S.; Cervera Villanueva, A.; Chalifour, M.; Chandratre, V.B.; Chatterjee, A.; Chattopadhyay, S.; Chattopadhyay, S.; Chaussard, L.; Chembra, S.; Chen, H.; Chen, K.; Chen, M.; Cherdack, D.; Chi, C.; Childress, S.; Choubey, S.; Choudhary, B.C.; Christodoulou, G.; Christofferson, C.; Church, E.; Cianci, D.; Cline, D.; Coan, T.; Cocco, A.; Coelho, J.; Cole, P.; Collin, G.; Conrad, J.M.; Convery, M.; Corey, R.; Corwin, L.; Cranshaw, J.; Crivelli, P.; Cronin-Hennessy, D.; Curioni, A.; Cushing, J.; Adams, D.L.; Dale, D.; Das, S.R.; Davenne, T.; Davies, G.S.; Davies, J.; Dawson, J.; De, K.; de Gouvea, A.; de Jong, J.K.; de Jong, P.; De Lurgio, P.; Decowski, M.; Delbart, A.; Densham, C.; Dharmapalan, R.; Dhingra, N.; Di Luise, S.; Diamantopoulou, M.; Diaz, J.S.; Diaz Bautista, G.; Diwan, M.; Djurcic, Z.; Dolph, J.; Drake, G.; Duchesneau, D.; Duvernois, M.; Duyang, H.; Dwyer, D.A.; Dye, S.; Dytman, S.; Eberly, B.; Edgecock, R.; Edmunds, D.; Elliott, S.; Elnimr, M.; Emery, S.; Endress, E.; Eno, S.; Ereditato, A.; Escobar, C.O.; Evans, J.; Falcone, A.; Falk, L.; Farbin, A.; Farnese, C.; Farzan, Y.; Fava, A.; Favilli, L.; Felde, J.; Felix, J.; Fernandes, S.; Fields, L.; Finch, A.; Fitton, M.; Fleming, B.; Forest, T.; Fowler, J.; Fox, W.; Fried, J.; Friedland, A.; Fuess, S.; Fujikawa, B.; Gago, A.; Gallagher, H.; Galymov, S.; Gamble, T.; Gandhi, R.; Garcia-Gamez, D.; Gardiner, S.; Garvey, G.; Gehman, V.M.; Gendotti, A.; Geronimo, G. d.; Ghag, C.; Ghoshal, P.; Gibin, D.; Gil-Botella, I.; Gill, R.; Girardelli, D.; Giri, A.; Glavin, S.; Goeldi, D.; Golapinni, S.; Gold, M.; Gomes, R.A.; Gomez Cadenas, J.J.; Goodman, M.C.; Gorbunov, D.; Goswami, S.; Graf, N.; Graf, N.; Graham, M.; Gramelini, E.; Gran, R.; Grant, C.; Grant, N.; Greco, V.; Greenlee, H.; Greenler, L.; Greenley, C.; Groh, M.; Grullon, S.; Grundy, T.; Grzelak, K.; Guardincerri, E.; Guarino, V.; Guarnaccia, E.; Guedes, G.P.; Guenette, R.; Guglielmi, A.; Habig, A.T.; Hackenburg, R.W.; Hackenburg, A.; Hadavand, H.; Haenni, R.; Hahn, A.; Haigh, M.D.; Haines, T.; Hamernik, T.; Handler, T.; Hans, S.; Harris, D.; Hartnell, J.; Hasegawa, T.; Hatcher, R.; Hatzikoutelis, A.; Hays, S.; Hazen, E.; Headley, M.; Heavey, A.; Heeger, K.; Heise, J.; Hennessy, K.; Hewes, J.; Higuera, A.; Hill, T.; Himmel, A.; Hogan, M.; Holanda, P.; Holin, A.; Honey, W.; Horikawa, S.; Horton-Smith, G.; Howard, B.; Howell, J.; Hurh, P.; Huston, J.; Hylen, J.; Imlay, R.; Insler, J.; Introzzi, G.; Ioanisyan, D.; Ioannisian, A.; Iwamoto, K.; Izmaylov, A.; Jackson, C.; Jaffe, D.E.; James, C.; James, E.; Jediny, F.; Jen, C.; Jhingan, A.; Jimenez, S.; Jo, J.H.; Johnson, M.; Johnson, R.; Johnstone, J.; Jones, B.J.; Joshi, J.; Jostlein, H.; Jung, C.K.; Junk, T.; Kaboth, A.; Kadel, R.; Kafka, T.; Kalousis, L.; Kamyshkov, Y.; Karagiorgi, G.; Karasavvas, D.; Karyotakis, Y.; Kaur, A.; Kaur, P.; Kayser, B.; Kazaryan, N.; Kearns, E.; Keener, P.; Kemboi, S.; Kemp, E.; Kettell, S.H.; Khabibullin, M.; Khandaker, M.; Khotjantsev, A.; Kirby, B.; Kirby, M.; Klein, J.; Kobilarcik, T.; Kohn, S.; Koizumi, G.; Kopylov, A.; Kordosky, M.; Kormos, L.; Kose, U.; Kostelecky, A.; Kramer, M.; Kreslo, I.; Kriske, R.; Kropp, W.; Kudenko, Y.; Kudryavtsev, V.A.; Kulagin, S.; Kumar, A.; Kumar, G.; Kumar, J.; Kumar, L.; Kutter, T.; Laminack, A.; Lande, K.; Lane, C.; Lang, K.; Lanni, F.; Learned, J.; Lebrun, P.; Lee, D.; Lee, H.; Lee, K.; Lee, W.M.; Leigui de Oliveira, M.A.; Li, Q.; Li, S.; Li, S.; Li, X.; Li, Y.; Li, Z.; Libo, J.; Lin, C.S.; Lin, S.; Ling, J.; Link, J.; Liptak, Z.; Lissauer, D.; Littenberg, L.; Littlejohn, B.; Liu, Q.; Liu, T.; Lockwitz, S.; Lockyer, N.; Loew, T.; Lokajicek, M.; Long, K.; Lopes, M.D.L.; Lopez, J.P.; Losecco, J.; Louis, W.; Lowery, J.; Luethi, M.; Luk, K.; Lundberg, B.; Lundin, T.; Luo, X.; Lux, T.; Lykken, J.; Machado, A.A.; Macier, J.R.; Magill, S.; Mahler, G.; Mahn, K.; Malek, M.; Malhotra, S.; Malon, D.; Mammoliti, F.; Mancina, S.; Mandal, S.K.; Mandodi, S.; Manly, S.L.; Mann, A.; Marchionni, A.; Marciano, W.; Mariani, C.; Maricic, J.; Marino, A.; Marshak, M.; Marshall, C.; Marshall, J.; Marteau, J.; Martin-Albo, J.; Martinez, D.; Matsuno, S.; Matthews, J.; Mauger, C.; Mavrokoridis, K.; Mayilyan, D.; Mazzucato, E.; McCauley, N.; McCluskey, E.; McConkey, N.; McDonald, K.; McFarland, K.S.; McGowan, A.M.; McGrew, C.; McKeown, R.; McNulty, D.; McTaggart, R.; Mefodiev, A.; Mehrian, M.; Mehta, P.; Mei, D.; Mena, O.; Menary, S.; Mendez, H.; Menegolli, A.; Meng, G.; Meng, Y.; Mertins, D.; Merritt, H.; Messier, M.; Metcalf, W.; Mewes, M.; Meyer, H.; Miao, T.; Milincic, R.; Miller, W.; Mills, G.; Mineev, O.; Miranda, O.; Mishra, C.S.; Mishra, S.R.; Mitrica, B.; Mladenov, D.; Mocioiu, I.; Mohanta, R.; Mokhov, N.; Montanari, C.; Montanari, D.; Moon, J.; Mooney, M.; Moore, C.; Morfin, J.; Morgan, B.; Morris, C.; Morse, W.; Moss, Z.; Mossey, C.; Moura, C.A.; Mousseau, J.; Mualem, L.; Muether, M.; Mufson, S.; Murphy, S.; Musser, J.; Musser, R.; Nakajima, Y.; Naples, D.; Napolitano, J.; Navarro, J.; Navas, D.; Nelson, J.; Nessi, M.; Newcomer, M.; Ng, Y.; Nichol, R.; Nicholls, T.C.; Nikolics, K.; Niner, E.; Norris, B.; Noto, F.; Novakova, P.; Novella, P.; Nowak, J.; Nunes, M.S.; O'Keeffe, H.; Oldeman, R.; Oliveira, R.; Olson, T.; Onishchuk, Y.; Osta, J.; Ovsjannikova, T.; Page, B.; Pakvasa, S.; Pal, S.; Palamara, O.; Palazzo, A.; Paley, J.; Palomares, C.; Pantic, E.; Paolone, V.; Papadimitriou, V.; Park, J.; Parke, S.; Parsa, Z.; Pascoli, S.; Patterson, R.; Patton, S.; Patzak, T.; Paulos, B.; Paulucci, L.; Pavlovic, Z.; Pawloski, G.; Peeters, S.; Pennacchio, E.; Perch, A.; Perdue, G.N.; Periale, L.; Perkin, J.D.; Pessard, H.; Petrillo, G.; Petti, R.; Petukhov, A.; Pietropaolo, F.; Plunkett, R.; Pordes, S.; Potekhin, M.; Potenza, R.; Potukuchi, B.; Poudyal, N.; Prokofiev, O.; Pruthi, N.; Przewlocki, P.; Pushka, D.; Qian, X.; Raaf, J.L.; Raboanary, R.; Radeka, V.; Radovic, A.; Raffelt, G.; Rakhno, I.; Rakotondramanana, H.T.; Rakotondravohitra, L.; Ramachers, Y.A.; Rameika, R.; Ramsey, J.; Rappoldi, A.; Raselli, G.; Ratoff, P.; Rebel, B.; Regenfus, C.; Reichenbacher, J.; Reitzner, D.; Remoto, A.; Renshaw, A.; Rescia, S.; Richardson, M.; Rielage, K.; Riesselmann, K.; Robinson, M.; Rochester, L.; Rodrigues, O.B.; Rodrigues, P.; Roe, B.; Rosen, M.; Roser, R.M.; Ross-Lonergan, M.; Rossella, M.; Rubbia, A.; Rubbia, C.; Rucinski, R.; von Rohr, C.Rudolph; Russell, B.; Ruterbories, D.; Saakyan, R.; Sahu, N.; Sala, P.; Samios, N.; Sanchez, F.; Sanchez, M.; Sands, B.; Santana, S.; Santorelli, R.; Santucci, G.; Saoulidou, N.; Scaramelli, A.; Schellman, H.; Schlabach, P.; Schmitt, R.; Schmitz, D.; Schneps, J.; Scholberg, K.; Schukraft, A.; Schwehr, J.; Segreto, E.; Seibert, S.; Sepulveda-Quiroz, J.A.; Sergiampietri, F.; Sexton-Kennedy, L.; Sgalaberna, D.; Shaevitz, M.; Shahi, J.; Shahsavarani, S.; Shanahan, P.; Shankar, S.U.; Sharma, R.; Sharma, R.K.; Shaw, T.; Shrock, R.; Shyrma, I.; Simos, N.; Sinev, G.; Singh, I.; Singh, J.; Singh, J.; Singh, V.; Sinnis, G.; Sippach, W.; Smargianaki, D.; Smy, M.; Snider, E.; Snopok, P.; Sobczyk, J.; Sobel, H.; Soderberg, M.; Solomey, N.; Sondheim, W.; Sorel, M.; Sousa, A.; Soustruznik, K.; Spitz, J.; Spooner, N.J.; Stancari, M.; Stancu, I.; Stefan, D.; Steiner, H.M.; Stewart, J.; Stock, J.; Stoica, S.; Stone, J.; Strait, J.; Strait, M.; Strauss, T.; Striganov, S.; Sulej, R.; Sullivan, G.; Sun, Y.; Suter, L.; Sutera, C.M.; Svoboda, R.; Szczerbinska, B.; Szelc, A.; Soldner-Rembold, S.; Talaga, R.; Tamsett, M.; Tariq, S.; Tatar, E.; Tayloe, R.; Taylor, C.; Taylor, D.; Terao, K.; Thiesse, M.; Thomas, J.; Thompson, L.F.; Thomson, M.; Thorn, C.; Thorpe, M.; Tian, X.; Tiedt, D.; Timm, S.C.; Tonazzo, A.; Tope, T.; Topkar, A.; Torres, F.R.; Torti, M.; Tortola, M.; Tortorici, F.; Toups, M.; Touramanis, C.; Tripathi, M.; Tropin, I.; Tsai, Y.; Tsang, K.V.; Tsenov, R.; Tufanli, S.; Tull, C.; Turner, J.; Tzanov, M.; Tziaferi, E.; Uchida, Y.; Urheim, J.; Usher, T.; Vagins, M.; Vahle, P.; Valdiviesso, G.A.; Valerio, L.; Vallari, Z.; Valle, J.; Van Berg, R.; Van de Water, R.; Van Gemmeren, P.; Varanini, F.; Varner, G.; Vasseur, G.; Vaziri, K.; Velev, G.; Ventura, S.; Verdugo, A.; Viant, T.; Vieira, T.V.; Vignoli, C.; Vilela, C.; Viren, B.; Vrba, T.; Wachala, T.; Wahl, D.; Wallbank, M.; Walsh, N.; Wang, B.; Wang, H.; Wang, L.; Wang, T.; Warburton, T.K.; Warner, D.; Wascko, M.; Waters, D.; Watson, T.B.; Weber, A.; Weber, M.; Wei, W.; Weinstein, A.; Wells, D.; Wenman, D.; Wetstein, M.; White, A.; Whitehead, L.; Whittington, D.; Wilking, M.; Willhite, J.; Wilson, P.; Wilson, R.J.; Winslow, L.; Wittich, P.; Wojcicki, S.; Wong, H.H.; Wood, K.; Worcester, E.; Worcester, M.; Wu, S.; Xin, T.; Yanagisawa, C.; Yang, S.; Yang, T.; Yarritu, K.; Ye, J.; Yeh, M.; Yershov, N.; Yonehara, K.; Yu, B.; Yu, J.; Zalesak, J.; Zalewska, A.; Zamorano, B.; Zang, L.; Zani, A.; Zani, A.; Zavala, G.; Zeller, G.; Zhang, C.; Zhang, C.; Zimmerman, E.D.; Zito, M.; Zwaska, R.

    2016-01-01

    This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modular liquid argon time-projection chamber (LArTPC) located deep underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE will also have a high-resolution and high-precision near detector.

  20. GNSS Single Frequency, Single Epoch Reliable Attitude Determination Method with Baseline Vector Constraint

    Directory of Open Access Journals (Sweden)

    Ang Gong

    2015-12-01

    Full Text Available For Global Navigation Satellite System (GNSS single frequency, single epoch attitude determination, this paper proposes a new reliable method with baseline vector constraint. First, prior knowledge of baseline length, heading, and pitch obtained from other navigation equipment or sensors are used to reconstruct objective function rigorously. Then, searching strategy is improved. It substitutes gradually Enlarged ellipsoidal search space for non-ellipsoidal search space to ensure correct ambiguity candidates are within it and make the searching process directly be carried out by least squares ambiguity decorrelation algorithm (LAMBDA method. For all vector candidates, some ones are further eliminated by derived approximate inequality, which accelerates the searching process. Experimental results show that compared to traditional method with only baseline length constraint, this new method can utilize a priori baseline three-dimensional knowledge to fix ambiguity reliably and achieve a high success rate. Experimental tests also verify it is not very sensitive to baseline vector error and can perform robustly when angular error is not great.

  1. Site Outcomes Baseline Multi Year Work Plan Volume 1, River Corridor Restoration Baseline

    International Nuclear Information System (INIS)

    Wintczak, T.M.

    2001-01-01

    The River Corridor Restoration volume is a compilation of Hanford Site scope, which excludes the approximately 194 km 2 Central Plateau. The River Corridor scope is currently contractually assigned to Fluor Hanford, Bechtel Hanford, inc., DynCorp, and Pacific Northwest National Laboratory, and others. The purpose of this project specification is to provide an overall scoping document for the River Corridor Restoration volume, and to provide a link with the overall Hanford Site River Corridor scope. Additionally, this specification provides an integrated and consolidated source of information for the various scopes, by current contract, for the River Corridor Restoration Baseline. It identifies the vision, mission, and goals, as well as the operational history of the Hanford Site, along with environmental setting and hazards

  2. Classification of baseline toxicants for QSAR predictions to replace fish acute toxicity studies.

    Science.gov (United States)

    Nendza, Monika; Müller, Martin; Wenzel, Andrea

    2017-03-22

    Fish acute toxicity studies are required for environmental hazard and risk assessment of chemicals by national and international legislations such as REACH, the regulations of plant protection products and biocidal products, or the GHS (globally harmonised system) for classification and labelling of chemicals. Alternative methods like QSARs (quantitative structure-activity relationships) can replace many ecotoxicity tests. However, complete substitution of in vivo animal tests by in silico methods may not be realistic. For the so-called baseline toxicants, it is possible to predict the fish acute toxicity with sufficient accuracy from log K ow and, hence, valid QSARs can replace in vivo testing. In contrast, excess toxicants and chemicals not reliably classified as baseline toxicants require further in silico, in vitro or in vivo assessments. Thus, the critical task is to discriminate between baseline and excess toxicants. For fish acute toxicity, we derived a scheme based on structural alerts and physicochemical property thresholds to classify chemicals as either baseline toxicants (=predictable by QSARs) or as potential excess toxicants (=not predictable by baseline QSARs). The step-wise approach identifies baseline toxicants (true negatives) in a precautionary way to avoid false negative predictions. Therefore, a certain fraction of false positives can be tolerated, i.e. baseline toxicants without specific effects that may be tested instead of predicted. Application of the classification scheme to a new heterogeneous dataset for diverse fish species results in 40% baseline toxicants, 24% excess toxicants and 36% compounds not classified. Thus, we can conclude that replacing about half of the fish acute toxicity tests by QSAR predictions is realistic to be achieved in the short-term. The long-term goals are classification criteria also for further groups of toxicants and to replace as many in vivo fish acute toxicity tests as possible with valid QSAR

  3. Robust extraction of baseline signal of atmospheric trace species using local regression

    Directory of Open Access Journals (Sweden)

    A. F. Ruckstuhl

    2012-11-01

    Full Text Available The identification of atmospheric trace species measurements that are representative of well-mixed background air masses is required for monitoring atmospheric composition change at background sites. We present a statistical method based on robust local regression that is well suited for the selection of background measurements and the estimation of associated baseline curves. The bootstrap technique is applied to calculate the uncertainty in the resulting baseline curve. The non-parametric nature of the proposed approach makes it a very flexible data filtering method. Application to carbon monoxide (CO measured from 1996 to 2009 at the high-alpine site Jungfraujoch (Switzerland, 3580 m a.s.l., and to measurements of 1,1-difluoroethane (HFC-152a from Jungfraujoch (2000 to 2009 and Mace Head (Ireland, 1995 to 2009 demonstrates the feasibility and usefulness of the proposed approach.

    The determined average annual change of CO at Jungfraujoch for the 1996 to 2009 period as estimated from filtered annual mean CO concentrations is −2.2 ± 1.1 ppb yr−1. For comparison, the linear trend of unfiltered CO measurements at Jungfraujoch for this time period is −2.9 ± 1.3 ppb yr−1.

  4. Developmental pathways of fitness, and not baseline, predict fitness status at the end of childhood

    OpenAIRE

    Rodrigues, Luis Paulo; Stodden, David F.; Lopes, Vítor P.

    2013-01-01

    It is generally described that children fitness levels increase along childhood. Complementary to this idea is the notion that the tracking of children’s fitness is good to moderate during this developmental time, and that baseline (initial values) of fitness are determinant on fitness development. The importance of developmental pathways has been recently reinforced by a theoretical argument that predicts that healthy lifestyle trajectories will evolve through either a positive or n...

  5. Baseline frontostriatal-limbic connectivity predicts reward-based memory formation.

    Science.gov (United States)

    Hamann, Janne M; Dayan, Eran; Hummel, Friedhelm C; Cohen, Leonardo G

    2014-12-01

    Reward mediates the acquisition and long-term retention of procedural skills in humans. Yet, learning under rewarded conditions is highly variable across individuals and the mechanisms that determine interindividual variability in rewarded learning are not known. We postulated that baseline functional connectivity in a large-scale frontostriatal-limbic network could predict subsequent interindividual variability in rewarded learning. Resting-state functional MRI was acquired in two groups of subjects (n = 30) who then trained on a visuomotor procedural learning task with or without reward feedback. We then tested whether baseline functional connectivity within the frontostriatal-limbic network predicted memory strength measured immediately, 24 h and 1 month after training in both groups. We found that connectivity in the frontostriatal-limbic network predicted interindividual variability in the rewarded but not in the unrewarded learning group. Prediction was strongest for long-term memory. Similar links between connectivity and reward-based memory were absent in two control networks, a fronto-parieto-temporal language network and the dorsal attention network. The results indicate that baseline functional connectivity within the frontostriatal-limbic network successfully predicts long-term retention of rewarded learning. © 2014 Wiley Periodicals, Inc.

  6. Localizing gravitational wave sources with single-baseline atom interferometers

    Science.gov (United States)

    Graham, Peter W.; Jung, Sunghoon

    2018-02-01

    Localizing sources on the sky is crucial for realizing the full potential of gravitational waves for astronomy, astrophysics, and cosmology. We show that the midfrequency band, roughly 0.03 to 10 Hz, has significant potential for angular localization. The angular location is measured through the changing Doppler shift as the detector orbits the Sun. This band maximizes the effect since these are the highest frequencies in which sources live for several months. Atom interferometer detectors can observe in the midfrequency band, and even with just a single baseline they can exploit this effect for sensitive angular localization. The single-baseline orbits around the Earth and the Sun, causing it to reorient and change position significantly during the lifetime of the source, and making it similar to having multiple baselines/detectors. For example, atomic detectors could predict the location of upcoming black hole or neutron star merger events with sufficient accuracy to allow optical and other electromagnetic telescopes to observe these events simultaneously. Thus, midband atomic detectors are complementary to other gravitational wave detectors and will help complete the observation of a broad range of the gravitational spectrum.

  7. Leveraging probabilistic peak detection to estimate baseline drift in complex chromatographic samples

    NARCIS (Netherlands)

    Lopatka, M.; Barcaru, A.; Sjerps, M.J.; Vivó-Truyols, G.

    2016-01-01

    Accurate analysis of chromatographic data often requires the removal of baseline drift. A frequently employed strategy strives to determine asymmetric weights in order to fit a baseline model by regression. Unfortunately, chromatograms characterized by a very high peak saturation pose a significant

  8. Socioeconomic position and participation in baseline and follow-up visits

    DEFF Research Database (Denmark)

    Bender, Anne M; Jørgensen, Torben; Hansen, Bodil Helbech

    2012-01-01

    Background:The aim of this paper was to identify the extent of socioeconomic inequality in participation at baseline and follow-up visits.Design:The Inter99 study is a randomized intervention with the aim of investigating the effects of an individualized lifestyle consultation on ischaemic heart ...... inequality in participation at baseline and follow-up visits. Effort should be made to increase participation in individualized lifestyle interventions among persons of low socioeconomic position. Otherwise, the consequence may be increased socioeconomic inequality in IHD....

  9. Baseline study of radiology services for the purpose of PACS evaluation

    International Nuclear Information System (INIS)

    Mun, S.K.; Benson, H.; Welsh, C.; Elliott, L.P.; Davros, W.

    1988-01-01

    This paper reports initial results of a radiology department baseline study of workload and data flow patterns for image generation, film library activities, report generation reporting activities at the film alternators and report transcription and validation. The authors analyze the film based operations prior to full implementation of the image management and communication system. The baseline study topics are examined

  10. Baseline LAW Glass Formulation Testing

    International Nuclear Information System (INIS)

    Kruger, Albert A.; Mooers, Cavin; Bazemore, Gina; Pegg, Ian L.; Hight, Kenneth; Lai, Shan Tao; Buechele, Andrew; Rielley, Elizabeth; Gan, Hao; Muller, Isabelle S.; Cecil, Richard

    2013-01-01

    The major objective of the baseline glass formulation work was to develop and select glass formulations that are compliant with contractual and processing requirements for each of the LAW waste streams. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, development of glass formulations to support ILAW qualification activities, and identification of glass formulation issues with respect to contract specifications and processing requirements

  11. Baseline atmospheric program Australia 1993

    International Nuclear Information System (INIS)

    Francey, R.J.; Dick, A.L.; Derek, N.

    1996-01-01

    This publication reports activities, program summaries and data from the Cape Grim Baseline Air Pollution Station in Tasmania, during the calendar year 1993. These activities represent Australia's main contribution to the Background Air Pollution Monitoring Network (BAPMoN), part of the World Meteorological Organization's Global Atmosphere Watch (GAW). The report includes 5 research reports covering trace gas sampling, ozone and radon interdependence, analysis of atmospheric dimethylsulfide and carbon-disulfide, sampling of trace gas composition of the troposphere, and sulfur aerosol/CCN relationship in marine air. Summaries of program reports for the calendar year 1993 are also included. Tabs., figs., refs

  12. MERI: an ultra-long-baseline Moon-Earth radio interferometer.

    Science.gov (United States)

    Burns, J. O.

    Radiofrequency aperture synthesis, pioneered by Ryle and his colleagues at Cambridge in the 1960's, has evolved to ever longer baselines and larger arrays in recent years. The limiting resolution at a given frequency for modern ground-based very-long-baseline interferometry is simply determined by the physical diameter of the Earth. A second-generation, totally space-based VLB network was proposed recently by a group at the Naval Research Laboratory. The next logical extension of space-based VLBI would be a station or stations on the Moon. The Moon could serve as an outpost or even the primary correlator station for an extended array of space-based antennas.

  13. Effect of water deprivation on baseline and stress-induced corticosterone levels in the Children's python (Antaresia childreni).

    Science.gov (United States)

    Dupoué, Andréaz; Angelier, Frédéric; Lourdais, Olivier; Bonnet, Xavier; Brischoux, François

    2014-02-01

    Corticosterone (CORT) secretion is influenced by endogenous factors (e.g., physiological status) and environmental stressors (e.g., ambient temperature). Heretofore, the impact of water deprivation on CORT plasma levels has not been thoroughly investigated. However, both baseline CORT and stress-induced CORT are expected to respond to water deprivation not only because of hydric stress per se, but also because CORT is an important mineralocorticoid in vertebrates. We assessed the effects of water deprivation on baseline CORT and stress-induced CORT, in Children's pythons (Antaresia childreni), a species that experiences seasonal droughts in natural conditions. We imposed a 52-day water deprivation on a group of unfed Children's pythons (i.e., water-deprived treatment) and provided water ad libitum to another group (i.e., control treatment). We examined body mass variations throughout the experiment, and baseline CORT and stress-induced CORT at the end of the treatments. Relative body mass loss averaged ~10% in pythons without water, a value 2 to 4 times higher compared to control snakes. Following re-exposition to water, pythons from the water-deprived treatment drank readily and abundantly and attained a body mass similar to pythons from the control treatment. Together, these results suggest a substantial dehydration as a consequence of water deprivation. Interestingly, stress-induced but not baseline CORT level was significantly higher in water-deprived snakes, suggesting that baseline CORT might not respond to this degree of dehydration. Therefore, possible mineralocorticoid role of CORT needs to be clarified in snakes. Because dehydration usually induces adjustments (reduced movements, lowered body temperature) to limit water loss, and decreases locomotor performances, elevated stress-induced CORT in water-deprived snakes might therefore compensate for altered locomotor performances. Future studies should test this hypothesis. Copyright © 2013 Elsevier Inc

  14. Wide-Baseline Stereo-Based Obstacle Mapping for Unmanned Surface Vehicles

    Science.gov (United States)

    Mou, Xiaozheng; Wang, Han

    2018-01-01

    This paper proposes a wide-baseline stereo-based static obstacle mapping approach for unmanned surface vehicles (USVs). The proposed approach eliminates the complicated calibration work and the bulky rig in our previous binocular stereo system, and raises the ranging ability from 500 to 1000 m with a even larger baseline obtained from the motion of USVs. Integrating a monocular camera with GPS and compass information in this proposed system, the world locations of the detected static obstacles are reconstructed while the USV is traveling, and an obstacle map is then built. To achieve more accurate and robust performance, multiple pairs of frames are leveraged to synthesize the final reconstruction results in a weighting model. Experimental results based on our own dataset demonstrate the high efficiency of our system. To the best of our knowledge, we are the first to address the task of wide-baseline stereo-based obstacle mapping in a maritime environment. PMID:29617293

  15. 2017 Annual Technology Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hand, M. M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Eberle, Annika [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Beiter, Philipp C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kurup, Parthiv [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Turchi, Craig S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Feldman, David J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Augustine, Chad R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maness, Michael [Formerly NREL; O' Connor, Patrick [Oak Ridge National Laboratory

    2018-03-26

    Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts as well as information from the Energy Information Administration for fuel-based technologies. The ATB has been reviewed by experts and it includes the following electricity generation technologies: land-based wind, offshore wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, coal, natural gas, nuclear, and conventional biopower. This webinar presentation introduces the 2017 ATB.

  16. Twenty-month follow-up of occlusal caries lesions deemed questionable at baseline

    DEFF Research Database (Denmark)

    Makhija, Sonia K; Gilbert, Gregg H; Funkhouser, Ellen

    2014-01-01

    -three clinicians from The National Dental Practice-Based Research Network participated in this study, recording lesion characteristics at baseline and lesion status at 20 months. RESULTS: At baseline, 1,341 QOC lesions were examined; the treatment that was planned for 1,033 of those at baseline was monitoring...... (oral hygiene instruction, applying or prescribing fluoride or varnish, or both), and the remaining 308 received a sealant (n = 192) or invasive therapy (n = 116). At the 20-month visit, clinicians continued to monitor 927 (90 percent) of the 1,033 monitored lesions. Clinicians decided to seal 61 (6...

  17. 40 CFR 80.245 - How does a small refiner apply for a sulfur baseline?

    Science.gov (United States)

    2010-07-01

    ... sulfur baseline? 80.245 Section 80.245 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Provisions § 80.245 How does a small refiner apply for a sulfur baseline? (a) Any refiner seeking small refiner status must apply for a refinery sulfur baseline by the deadline under § 80.235 for each of the...

  18. Stack Characterization in CryoSat Level1b SAR/SARin Baseline C

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Di Giacinto, Andrea; Bouffard, Jerome; Féménias, Pierre; Parrinello, Tommaso

    2015-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. CryoSat is the first altimetry mission operating in SAR mode and it carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. The current CryoSat IPF (Instrument Processing Facility), Baseline B, was released in operation in February 2012. After more than 2 years of development, the release in operations of the Baseline C is expected in the first half of 2015. It is worth recalling here that the CryoSat SAR/SARin IPF1 generates 20Hz waveforms in correspondence of an approximately equally spaced set of ground locations on the Earth surface, i.e. surface samples, and that a surface sample gathers a collection of single-look echoes coming from the processed bursts during the time of visibility. Thus, for a given surface sample, the stack can be defined as the collection of all the single-look echoes pointing to the current surface sample, after applying all the necessary range corrections. The L1B product contains the power average of all the single-look echoes in the stack: the multi-looked L1B waveform. This reduces the data volume, while removing some information contained in the single looks, useful for characterizing the surface and modelling the L1B waveform. To recover such information, a set of parameters has been added to the L1B product: the stack characterization or beam behaviour parameters. The stack characterization, already included in previous Baselines, has been reviewed and expanded in Baseline C. This poster describes all the stack characterization parameters, detailing what they represent and how they have been computed. In details, such parameters can be summarized in: - Stack

  19. The steroids for corneal ulcers trial: study design and baseline characteristics.

    Science.gov (United States)

    Srinivasan, Muthiah; Mascarenhas, Jeena; Rajaraman, Revathi; Ravindran, Meenakshi; Lalitha, Prajna; Glidden, David V; Ray, Kathryn J; Hong, Kevin C; Oldenburg, Catherine E; Lee, Salena M; Zegans, Michael E; McLeod, Stephen D; Lietman, Thomas M; Acharya, Nisha R

    2012-02-01

    To provide comprehensive trial methods and baseline data for the Steroids for Corneal Ulcers Trial and to present epidemiological characteristics such as risk factors, causative organisms, and ulcer severity. Baseline data from a 1:1 randomized, placebo-controlled, double-masked clinical trial comparing prednisolone phosphate, 1%, with placebo as adjunctive therapy for the treatment of bacterial corneal ulcers. Eligible patients had a culture-positive bacterial corneal ulcer and had been taking moxifloxacin for 48 hours. The primary outcome for the trial is best spectacle-corrected visual acuity at 3 months from enrollment. This report provides comprehensive baseline data, including best spectacle-corrected visual acuity, infiltrate size, microbiological results, and patient demographics, for patients enrolled in the trial. Of 500 patients enrolled, 97% were in India. Two hundred twenty patients (44%) were agricultural workers. Median baseline visual acuity was 0.84 logMAR (Snellen, 20/125) (interquartile range, 0.36-1.7; Snellen, 20/50 to counting fingers). Baseline visual acuity was not significantly different between the United States and India. Ulcers in India had larger infiltrate/scar sizes (P = .04) and deeper infiltrates (P = .04) and were more likely to be localized centrally (P = .002) than ulcers enrolled in the United States. Gram-positive bacteria were the most common organisms isolated from the ulcers (n = 366, 72%). The Steroids for Corneal Ulcers Trial will compare the use of a topical corticosteroid with placebo as adjunctive therapy for bacterial corneal ulcers. Patients enrolled in this trial had diverse ulcer severity and on average significantly reduced visual acuity at presentation. clinicaltrials.gov Identifier: NCT00324168.

  20. Relation of N-terminal pro B-type natriuretic peptide levels after symptom-limited exercise to baseline and ischemia levels.

    Science.gov (United States)

    van der Zee, P Marc; Verberne, Hein J; van Spijker, Rianne C; van Straalen, Jan P; Fischer, Johan C; Sturk, Augueste; van Eck-Smit, Berthe L F; de Winter, Robbert J

    2009-03-01

    Circulating levels of B-type natriuretic peptide (BNP) and the amino-terminal portion of the prohormone (NT-proBNP) have been reported to increase immediately after myocardial ischemia. The association between extent of exercise-induced myocardial ischemia measured using myocardial perfusion scintigraphy and the magnitude and time course of changes in NT-proBNP was studied. One hundred one patients underwent symptom-limited exercise myocardial perfusion scintigraphy. Myocardial ischemia was assessed semiquantitatively. Serum samples were obtained before the start of exercise (baseline), at maximal exercise, and every hour up to 6 hours after maximal exercise. Myocardial ischemia was present in 37 patients (37%). NT-proBNP rapidly increased during exercise (to 113%, interquartile range 104 to 144, and 118%, interquartile range 106 to 142, of baseline, respectively), with a second peak at 4 (141%, interquartile range 119 to 169) and 5 hours (136%, interquartile range 93 to 188), respectively. Absolute changes between NT-proBNP at baseline and at maximum exercise in patients with versus without ischemia were similar (median, 30 pg/ml, interquartile range 7 to 45 vs 15, interquartile range 4 to 46, respectively, p = 0.230), but absolute change between baseline and the secondary peak was higher in patients with ischemia than in patients without ischemia (median 64 pg/ml, interquartile range 32 to 172 vs 34, interquartile range 19 to 85, respectively, p = 0.024). In multivariate linear stepwise regression analysis of determinants of changes in NT-proBNP after exercise, baseline NT-proBNP was the only independent determinant of absolute changes at maximum exercise, whereas the presence of ischemia was not predictive. Baseline NT-proBNP, cystatin C, and end-systolic volume were independent determinants of the absolute increase to secondary peak levels. In conclusion, myocardial ischemia per se did not lead to additional increases in NT-proBNP within 6 hours after exercise.

  1. 77 FR 21760 - Atmos Energy Colorado/Kansas Division; Notice of Baseline Filing

    Science.gov (United States)

    2012-04-11

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-19-000] Atmos Energy Colorado/Kansas Division; Notice of Baseline Filing Take notice that on March 30, 2012, Atmos Energy Colorado/Kansas Division (Atmos) submitted a baseline filing of their Statement of Operating Conditions for...

  2. Baseline Neurocognitive Test Results In Non-concussed Athletes: Does Sleep Matter?

    OpenAIRE

    McClure, D. Jake; Zuckerman, Scott L.; Kutscher, Scott J.; Gregory, Andrew; Solomon, Gary S.

    2013-01-01

    Objectives: When managing sport-related concussions (SRC), sports medicine physicians utilize serial neurocognitive assessments and self-reported symptom inventories when evaluating athlete recovery and safety for returning to play (RTP). Since post-concussive RTP goals include symptom resolution and return to neurocognitive baseline, clinical decisions rest on an understanding of modifiers of baseline performance. Several studies have reported the influence of age, gender and sport on baseli...

  3. CryoSat Ice Processor: High-Level Overview of Baseline-C Data and Quality-Control

    Science.gov (United States)

    Mannan, R.; Webb, E.; Hall, A.; Bouffard, J.; Femenias, P.; Parrinello, T.; Bouffard, J.; Brockley, D.; Baker, S.; Scagliola, M.; Urien, S.

    2016-08-01

    Since April 2015, the CryoSat ice products have been generated with the new Baseline-C Instrument Processing Facilities (IPFs). This represents a major upgrade to the CryoSat ice IPFs and is the baseline for the second CryoSat Reprocessing Campaign. Baseline- C introduces major evolutions with respect to Baseline- B, most notably the release of freeboard data within the L2 SAR products, following optimisation of the SAR retracker. Additional L2 improvements include a new Arctic Mean Sea Surface (MSS) in SAR; a new tuneable land ice retracker in LRM; and a new Digital Elevation Model (DEM) in SARIn. At L1B new attitude fields have been introduced and existing datation and range biases reduced. This paper provides a high level overview of the changes and evolutions implemented at Baseline-C in order to improve CryoSat L1B and L2 data characteristics and exploitation over polar regions. An overview of the main Quality Control (QC) activities performed on operational Baseline-C products is also presented.

  4. Astrometry of 25 Southern Hemisphere Radio Sources From A VLBI Short-Baseline Survey

    National Research Council Canada - National Science Library

    Fey, Alan

    2004-01-01

    .... These positions are derived from Mark III Very Long Baseline Interferometry observations made between 2003 September and 2004 May on the intra-Australia baseline connecting Hobart, Tasmania and Parkes, New South Wales...

  5. Baseline and cognition activated brain SPECT imaging in depression

    International Nuclear Information System (INIS)

    Zhao Jinhua; Lin Xiangtong; Jiang Kaida; Liu Yongchang; Xu Lianqin

    1998-01-01

    Purpose: To evaluate the regional cerebral blood flow (rCBF) abnormalities through the semiquantitative analysis of the baseline and cognition activated rCBF imaging in unmedicated depressed patients. Methods: 27 depressed patients unmedicated by anti-depressants were enrolled. The diagnosis (depression of moderate degree with somatization) was confirmed by the ICD-10 criteria. 15 age matched normal controls were studied under identical conditions. Baseline and cognition activated 99m Tc-ECD SPECT were performed on 21 of the 27 patients with depression and 13 of the 15 normal controls. Baseline 99m Tc-ECD SPECT alone were performed on the rest 6 patients with depression and 2 normal controls. The cognitive activation is achieved by Wisconsin Card Sorting Test (WCST). 1110 MBq of 99m Tc-ECD was administered by intravenous bolus injection 5 minutes after the onset of the WCST. Semi-quantitative analysis was conducted with the 7th, 8th, 9th, 10th, 11th slices of the transaxial imaging. rCBF ratios of every ROI were calculated using the average tissue activity in the region divided by the maximum activity in the cerebellum. Results: 1) The baseline rCBF of left frontal (0.720) and left temporal lobe (0.720) were decreased significantly in depressed patients comparing with those of the control subjects. 2) The activated rCBF of left frontal lobe (0.719) and left temporal lobe (0.690), left parietal lobe (0.701) were decreased evidently than those of the controls. Conclusions: 1) Hypoperfusions of left frontal and left temporal cortexes were identified in patients with depression. 2) The hypoperfusion of left frontal and left temporal cortexes may be the cause of cognition disorder and depressed mood in patients with depression. 3) Cognition activated brain perfusion imaging is helpful for making a more accurate diagnosis of depression

  6. Long baseline Super-Beam experiments in Europe within LAGUNA

    CERN Document Server

    Coloma, Pilar; Pascoli, Silvia

    2011-01-01

    We explore the physics reach of several possible configurations for a Super-Beam experiment in Europe, focusing on the possibilities of discovering $\\theta_{13}$, CP violation in the leptonic sector and the ordering of neutrino mass eigenstates. We consider the three different detector technologies: Water \\v{C}erenkov, Liquid Argon and Liquid Scintillator, and seven possible sites in Europe which would be able to host such a detector underground. The distances to these sites from CERN, where the beam would be originated, go from 130 km to 2300 km. The neutrino flux is optimized in each case as to match the first oscillation peak for each of the baselines under consideration. We also study the impact of several experimental factors in the performance of each detector technology. These include the reconstruction efficiencies for quasi-elastic events, the rejection efficiencies for the neutral-current backgrounds, the ratio between running times in neutrino and antineutrino modes and the systematic uncertainties...

  7. How to deal with cost differences at baseline

    NARCIS (Netherlands)

    Van Asselt, Antoinette D.I.; Van Mastrigt, Ghislaine A.P.G.; Dirksen, Carmen D.; Arntz, Arnoud; Severens, Johan L.; Kessels, Alfons G.H.

    BACKGROUND: To our knowledge, adjustment for baseline imbalances in costs has never been performed in trial-based cost-effectiveness analyses. METHODS: We used data from a clinical trial performed in the Netherlands comparing two outpatient psychotherapies: schema-focused therapy (SFT) versus

  8. Why some people discount more than others: Baseline activation in the dorsal PFC mediates the link between COMT genotype and impatient choice

    Directory of Open Access Journals (Sweden)

    Lorena R. R. Gianotti

    2012-05-01

    Full Text Available Individuals differ widely in how steeply they discount future rewards. The sources of these stable individual differences in delay discounting (DD are largely unknown. One candidate is the COMT Val158Met polymorphism, known to modulate prefrontal dopamine levels and affect DD. To identify possible neural mechanisms by which this polymorphism may contribute to stable individual DD differences, we measured 73 participants’ neural baseline activation using resting electroencephalogram (EEG. Such neural baseline activation measures are highly heritable and stable over time, thus an ideal endophenotype candidate to explain how genes may influence behavior via individual differences in neural function. After EEG-recording, participants made a series of incentive-compatible intertemporal choices to determine the steepness of their DD. We found that COMT significantly affected DD and that this effect was mediated by baseline activation level in the left dorsal prefrontal cortex (DPFC: (i COMT had a significant effect on DD such that the number of Val alleles was positively correlated with steeper DD (higher numbers of Val alleles means greater COMT activity and thus lower dopamine levels. (ii A whole-brain search identified a cluster in left DPFC where baseline activation was correlated with DD; lower activation was associated with steeper DD. (iii COMT had a significant effect on the baseline activation level in this left DPFC cluster such that a higher number of Val alleles was associated with lower baseline activation. (iv The effect of COMT on DD was explained by the mediating effect of neural baseline activation in the left DPFC cluster. Our study thus establishes baseline activation level in left DPFC as salient neural signature in the form of an endophenotype that mediates the link between COMT and DD.

  9. High baseline activity in inferior temporal cortex improves neural and behavioral discriminability during visual categorization

    Science.gov (United States)

    Emadi, Nazli; Rajimehr, Reza; Esteky, Hossein

    2014-01-01

    Spontaneous firing is a ubiquitous property of neural activity in the brain. Recent literature suggests that this baseline activity plays a key role in perception. However, it is not known how the baseline activity contributes to neural coding and behavior. Here, by recording from the single neurons in the inferior temporal cortex of monkeys performing a visual categorization task, we thoroughly explored the relationship between baseline activity, the evoked response, and behavior. Specifically we found that a low-frequency (baseline activity. This enhancement of the baseline activity was then followed by an increase in the neural selectivity and the response reliability and eventually a higher behavioral performance. PMID:25404900

  10. Choice of baseline climate data impacts projected species' responses to climate change.

    Science.gov (United States)

    Baker, David J; Hartley, Andrew J; Butchart, Stuart H M; Willis, Stephen G

    2016-07-01

    Climate data created from historic climate observations are integral to most assessments of potential climate change impacts, and frequently comprise the baseline period used to infer species-climate relationships. They are often also central to downscaling coarse resolution climate simulations from General Circulation Models (GCMs) to project future climate scenarios at ecologically relevant spatial scales. Uncertainty in these baseline data can be large, particularly where weather observations are sparse and climate dynamics are complex (e.g. over mountainous or coastal regions). Yet, importantly, this uncertainty is almost universally overlooked when assessing potential responses of species to climate change. Here, we assessed the importance of historic baseline climate uncertainty for projections of species' responses to future climate change. We built species distribution models (SDMs) for 895 African bird species of conservation concern, using six different climate baselines. We projected these models to two future periods (2040-2069, 2070-2099), using downscaled climate projections, and calculated species turnover and changes in species-specific climate suitability. We found that the choice of baseline climate data constituted an important source of uncertainty in projections of both species turnover and species-specific climate suitability, often comparable with, or more important than, uncertainty arising from the choice of GCM. Importantly, the relative contribution of these factors to projection uncertainty varied spatially. Moreover, when projecting SDMs to sites of biodiversity importance (Important Bird and Biodiversity Areas), these uncertainties altered site-level impacts, which could affect conservation prioritization. Our results highlight that projections of species' responses to climate change are sensitive to uncertainty in the baseline climatology. We recommend that this should be considered routinely in such analyses. © 2016 John Wiley

  11. Association between baseline psychological attributes and mental health outcomes after soldiers returned from deployment.

    Science.gov (United States)

    Shen, Yu-Chu; Arkes, Jeremy; Lester, Paul B

    2017-10-05

    Psychological health is vital for effective employees, especially in stressful occupations like military and public safety sectors. Yet, until recently little empirical work has made the link between requisite psychological resources and important mental health outcomes across time in those sectors. In this study we explore the association between 14 baseline psychological health attributes (such as adaptability, coping ability, optimism) and mental health outcomes following exposure to combat deployment. Retrospective analysis of all U.S. Army soldiers who enlisted between 2009 and 2012 and took the Global Assessment Tools (GAT) before their first deployment (n = 63,186). We analyze whether a soldier screened positive for depression and posttraumatic stress disorder (PTSD) after returning from deployment using logistic regressions. Our key independent variables are 14 psychological attributes based on GAT, and we control for relevant demographic and service characteristics. In addition, we generate a composite risk score for each soldier based on the predicted probabilities from the above multivariate model using just baseline psychological attributes and demographic information. Comparing those who scored in the bottom 5 percentile of each attribute to those in the top 95 percentile, the odds ratio of post-deployment depression symptoms ranges from 1.21 (95% CI 1.06, 1.40) for organizational trust to 1.73 (CI 1.52, 1.97) for baseline depression. The odds ratio of positive screening of PTSD symptoms ranges from 1.22 for family support (CI 1.08, 1.38) to 1.51 for baseline depression (CI 1.32, 1.73). The risk profile analysis shows that 31% of those who screened positive for depression and 27% of those who screened positive for PTSD were concentrated among the top 5% high risk population. A set of validated, self-reported questions administered early in a soldier's career can predict future mental health problems, and can be used to improve workforce fit and

  12. The impact of GPS receiver modifications and ionospheric activity on Swarm baseline determination

    Science.gov (United States)

    Mao, X.; Visser, P. N. A. M.; van den IJssel, J.

    2018-05-01

    The European Space Agency (ESA) Swarm mission is a satellite constellation launched on 22 November 2013 aiming at observing the Earth geomagnetic field and its temporal variations. The three identical satellites are equipped with high-precision dual-frequency Global Positioning System (GPS) receivers, which make the constellation an ideal test bed for baseline determination. From October 2014 to August 2016, a number of GPS receiver modifications and a new GPS Receiver Independent Exchange Format (RINEX) converter were implemented. Moreover, the on-board GPS receiver performance has been influenced by the ionospheric scintillations. The impact of these factors is assessed for baseline determination of the pendulum formation flying Swarm-A and -C satellites. In total 30 months of data - from 15 July 2014 to the end of 2016 - is analyzed. The assessment includes analysis of observation residuals, success rate of GPS carrier phase ambiguity fixing, a consistency check between the so-called kinematic and reduced-dynamic baseline solution, and validations of orbits by comparing with Satellite Laser Ranging (SLR) observations. External baseline solutions from The German Space Operations Center (GSOC) and Astronomisches Institut - Universität Bern (AIUB) are also included in the comparison. Results indicate that the GPS receiver modifications and RINEX converter changes are effective to improve the baseline determination. This research eventually shows a consistency level of 9.3/4.9/3.0 mm between kinematic and reduced-dynamic baselines in the radial/along-track/cross-track directions. On average 98.3% of the epochs have kinematic solutions. Consistency between TU Delft and external reduced-dynamic baseline solutions is at a level of 1 mm level in all directions.

  13. Early return to baseline range of motion and strength after anterior shoulder instability surgery: a Multicenter Orthopaedic Outcomes Network (MOON) shoulder group cohort study.

    Science.gov (United States)

    Buckwalter V, Joseph A; Wolf, Brian R; Glass, Natalie; Bollier, Matt; Kuhn, John E; Hettrich, Carolyn M

    2018-03-23

    Patients often return to higher-level activities and sports at 4 to 8 months after anterior shoulder stabilization procedures. It is unknown what percentage of patients have regained normal function at this time frame and what factors predict residual deficits, range of motion (ROM), and strength after anterior shoulder instability surgery. Ten participating sites throughout the United States enrolled patients in a prospective cohort study including primary, revision, arthroscopic, and open anterior stabilization procedures. Baseline demographic data and patient outcomes questionnaires were collected with initial physical examination, treatment, surgical findings, and surgical repair details. At the 6-month follow-up visit, ROM and strength measurements were collected and compared with preoperative measurements. There were 348 patients identified who underwent surgical treatment for anterior shoulder instability. Of these, 259 patients (74.0%) returned to baseline, and 89 (26.0%) did not return to baseline shoulder ROM (≥20° loss of ROM) or strength. A higher Beighton score (P = .01) and number of dislocations (P baseline ROM and strength at early follow-up. No surgical variables were found to influence return to baseline function, including open vs. arthroscopic surgery, primary vs. revision surgery, and number of suture anchors. By 4 to 8 months postoperatively, 76% of patients return to baseline ROM, 98% return to baseline strength, and 74% return to both baseline ROM and strength. An increased number of dislocations and generalized joint laxity were associated with failure to return to baseline ROM and strength at early follow-up after anterior shoulder instability surgery. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Ankylosing Spondylitis Patients Commencing Biologic Therapy Have High Baseline Levels of Comorbidity: A Report from the Australian Rheumatology Association Database

    Directory of Open Access Journals (Sweden)

    John Oldroyd

    2009-01-01

    Full Text Available Aims. To compare the baseline characteristics of a population-based cohort of patients with ankylosing spondylitis (AS commencing biological therapy to the reported characteristics of bDMARD randomised controlled trials (RCTs participants. Methods. Descriptive analysis of AS participants in the Australian Rheumatology Association Database (ARAD who were commencing bDMARD therapy. Results. Up to December 2008, 389 patients with AS were enrolled in ARAD. 354 (91.0% had taken bDMARDs at some time, and 198 (55.9% completed their entry questionnaire prior to or within 6 months of commencing bDMARDs. 131 (66.1% had at least one comorbid condition, and 24 (6.8% had a previous malignancy (15 nonmelanoma skin, 4 melanoma, 2 prostate, 1 breast, cervix, and bowel. Compared with RCT participants, ARAD participants were older, had longer disease duration and higher baseline disease activity. Conclusions. AS patients commencing bDMARDs in routine care are significantly different to RCT participants and have significant baseline comorbidities.

  15. A Mean-Shift-Based Feature Descriptor for Wide Baseline Stereo Matching

    Directory of Open Access Journals (Sweden)

    Yiwen Dou

    2015-01-01

    Full Text Available We propose a novel Mean-Shift-based building approach in wide baseline. Initially, scale-invariance feature transform (SIFT approach is used to extract relatively stable feature points. As to each matching SIFT feature point, it needs a reasonable neighborhood range so as to choose feature points set. Subsequently, in view of selecting repeatable and high robust feature points, Mean-Shift controls corresponding feature scale. At last, our approach is employed to depth image acquirement in wide baseline and Graph Cut algorithm optimizes disparity information. Compared with the existing methods such as SIFT, speeded up robust feature (SURF, and normalized cross-correlation (NCC, the presented approach has the advantages of higher robustness and accuracy rate. Experimental results on low resolution image and weak feature description in wide baseline confirm the validity of our approach.

  16. Profile of NASA software engineering: Lessons learned from building the baseline

    Science.gov (United States)

    Hall, Dana; Mcgarry, Frank

    1993-01-01

    It is critically important in any improvement activity to first understand the organization's current status, strengths, and weaknesses and, only after that understanding is achieved, examine and implement promising improvements. This fundamental rule is certainly true for an organization seeking to further its software viability and effectiveness. This paper addresses the role of the organizational process baseline in a software improvement effort and the lessons we learned assembling such an understanding for NASA overall and for the NASA Goddard Space Flight Center in particular. We discuss important, core data that must be captured and contrast that with our experience in actually finding such information. Our baselining efforts have evolved into a set of data gathering, analysis, and crosschecking techniques and information presentation formats that may prove useful to others seeking to establish similar baselines for their organization.

  17. Wide baseline stereo matching based on double topological relationship consistency

    Science.gov (United States)

    Zou, Xiaohong; Liu, Bin; Song, Xiaoxue; Liu, Yang

    2009-07-01

    Stereo matching is one of the most important branches in computer vision. In this paper, an algorithm is proposed for wide-baseline stereo vision matching. Here, a novel scheme is presented called double topological relationship consistency (DCTR). The combination of double topological configuration includes the consistency of first topological relationship (CFTR) and the consistency of second topological relationship (CSTR). It not only sets up a more advanced model on matching, but discards mismatches by iteratively computing the fitness of the feature matches and overcomes many problems of traditional methods depending on the powerful invariance to changes in the scale, rotation or illumination across large view changes and even occlusions. Experimental examples are shown where the two cameras have been located in very different orientations. Also, epipolar geometry can be recovered using RANSAC by far the most widely method adopted possibly. By the method, we can obtain correspondences with high precision on wide baseline matching problems. Finally, the effectiveness and reliability of this method are demonstrated in wide-baseline experiments on the image pairs.

  18. Very long baseline interferometry applied to polar motion, relativity, and geodesy. Ph.D. thesis

    International Nuclear Information System (INIS)

    Ma, C.

    1978-01-01

    The causes and effects of diurnal polar motion are described. An algorithm was developed for modeling the effects on very long baseline interferometry observables. A selection was made between two three-station networks for monitoring polar motion. The effects of scheduling and the number of sources observed on estimated baseline errors are discussed. New hardware and software techniques in very long baseline interferometry are described

  19. Geometry-specified troposphere decorrelation for subcentimeter real-time kinematic solutions over long baselines

    Science.gov (United States)

    Li, Bofeng; Feng, Yanming; Shen, Yunzhong; Wang, Charles

    2010-11-01

    Real-time kinematic (RTK) GPS techniques have been extensively developed for applications including surveying, structural monitoring, and machine automation. Limitations of the existing RTK techniques that hinder their applications for geodynamics purposes are twofold: (1) the achievable RTK accuracy is on the level of a few centimeters and the uncertainty of vertical component is 1.5-2 times worse than those of horizontal components and (2) the RTK position uncertainty grows in proportional to the base-to-rover distances. The key limiting factor behind the problems is the significant effect of residual tropospheric errors on the positioning solutions, especially on the highly correlated height component. This paper develops the geometry-specified troposphere decorrelation strategy to achieve the subcentimeter kinematic positioning accuracy in all three components. The key is to set up a relative zenith tropospheric delay (RZTD) parameter to absorb the residual tropospheric effects and to solve the established model as an ill-posed problem using the regularization method. In order to compute a reasonable regularization parameter to obtain an optimal regularized solution, the covariance matrix of positional parameters estimated without the RZTD parameter, which is characterized by observation geometry, is used to replace the quadratic matrix of their "true" values. As a result, the regularization parameter is adaptively computed with variation of observation geometry. The experiment results show that new method can efficiently alleviate the model's ill condition and stabilize the solution from a single data epoch. Compared to the results from the conventional least squares method, the new method can improve the long-range RTK solution precision from several centimeters to the subcentimeter in all components. More significantly, the precision of the height component is even higher. Several geosciences applications that require subcentimeter real-time solutions can

  20. Improving the accuracy of energy baseline models for commercial buildings with occupancy data

    International Nuclear Information System (INIS)

    Liang, Xin; Hong, Tianzhen; Shen, Geoffrey Qiping

    2016-01-01

    Highlights: • We evaluated several baseline models predicting energy use in buildings. • Including occupancy data improved accuracy of baseline model prediction. • Occupancy is highly correlated with energy use in buildings. • This simple approach can be used in decision makings of energy retrofit projects. - Abstract: More than 80% of energy is consumed during operation phase of a building’s life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. The results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

  1. Baseline PSA in a Spanish male population aged 40-49 years anticipates detection of prostate cancer.

    Science.gov (United States)

    Angulo, J C; Viñas, M A; Gimbernat, H; Fata, F Ramón de; Granados, R; Luján, M

    2015-12-01

    We researched the usefulness of optimizing prostate cancer (PC) screening in our community using baseline PSA readings in men between 40-49 years of age. A retrospective study was performed that analyzed baseline PSA in the fifth decade of life and its ability to predict the development of PC in a population of Madrid (Spain). An ROC curve was created and a cutoff was proposed. We compared the evolution of PSA from baseline in patients with consecutive readings using the Friedman test. We established baseline PSA ranges with different risks of developing cancer and assessed the diagnostic utility of the annual PSA velocity (PSAV) in this population. Some 4,304 men aged 40-49 years underwent opportunistic screening over the course of 17 years, with at least one serum PSA reading (6,001 readings) and a mean follow-up of 57.1±36.8 months. Of these, 768 underwent biopsy of some organ, and 104 underwent prostate biopsy. Fourteen patients (.33%) were diagnosed with prostate cancer. The median baseline PSA was .74 (.01-58.5) ng/mL for patients without PC and 4.21 (.76-47.4) ng/mL for those with PC. The median time from the reading to diagnosis was 26.8 (1.5-143.8) months. The optimal cutoff for detecting PC was 1.9ng/mL (sensitivity, 92.86%; specificity, 92.54%; PPV, 3.9%; NPV, 99.97%), and the area under the curve was 92.8%. In terms of the repeated reading, the evolution of the PSA showed no statistically significant differences between the patients without cancer (p=.56) and those with cancer (P=.64). However, a PSAV value >.3ng/mL/year revealed high specificity for detecting cancer in this population. A baseline PSA level ≥1.9ng/mL in Spanish men aged 40-49 years predicted the development of PC. This value could therefore be of use for opportunistic screening at an early age. An appropriate follow-up adapted to the risk of this population needs to be defined, but an annual PSAV ≥.3ng/mL/year appears of use for reaching an early diagnosis. Copyright © 2015 AEU

  2. An evaluation of space time cube representation of spatiotemporal patterns.

    Science.gov (United States)

    Kristensson, Per Ola; Dahlbäck, Nils; Anundi, Daniel; Björnstad, Marius; Gillberg, Hanna; Haraldsson, Jonas; Mårtensson, Ingrid; Nordvall, Mathias; Ståhl, Josefine

    2009-01-01

    Space time cube representation is an information visualization technique where spatiotemporal data points are mapped into a cube. Information visualization researchers have previously argued that space time cube representation is beneficial in revealing complex spatiotemporal patterns in a data set to users. The argument is based on the fact that both time and spatial information are displayed simultaneously to users, an effect difficult to achieve in other representations. However, to our knowledge the actual usefulness of space time cube representation in conveying complex spatiotemporal patterns to users has not been empirically validated. To fill this gap, we report on a between-subjects experiment comparing novice users' error rates and response times when answering a set of questions using either space time cube or a baseline 2D representation. For some simple questions, the error rates were lower when using the baseline representation. For complex questions where the participants needed an overall understanding of the spatiotemporal structure of the data set, the space time cube representation resulted in on average twice as fast response times with no difference in error rates compared to the baseline. These results provide an empirical foundation for the hypothesis that space time cube representation benefits users analyzing complex spatiotemporal patterns.

  3. NA61/SHINE Data For Long Baseline Neutrino Experiments

    CERN Document Server

    Hälser, Alexis

    2015-01-01

    Accelerator based long baseline neutrino experiments require precise neutrino fl ux predictions to reach their physics goals. These experiments are commonly based on a set of two detectors. At the near detector, cross section measurements are performed and the neutrino fl ux can be observed before oscillation, while at the far detector the signal for neutrino oscillations is studied. An accurate knowledge on hadron production is mandatory in order to predict the neutrino fluxes. The NA61/SHINE facility at the CERN SPS has proven its ability to deliver high quality measurements of hadron production for the long baseline neutrino experiments. In this paper, the latest results from N A61 /SHINE for the neutrino physics programme are reviewed and future plans are presented.

  4. Baseline ecological risk assessment Salmon Site, Lamar County, Mississippi

    International Nuclear Information System (INIS)

    1995-04-01

    The Salmon Site (SS), formerly the Tatum Dome Test Site, located in Mississippi was the site of two nuclear and two gas explosion tests conducted between 1964 and 1970. A consequence of these testing activities is that radionuclides were released into the salt dome, where they are presently contained. During reentry drilling and other site activities, incidental liquid and solid wastes that contained radioactivity were generated, resulting in some soil, ground water and equipment contamination. As part of the remedial investigation effort, a Baseline Ecological Risk Assessment was conducted at the SS. The purpose is to gauge ecological and other environmental impacts attributable to past activities at the former test facility. The results of this facility-specific baseline risk assessment are presented in this document

  5. Baseline ecological risk assessment Salmon Site, Lamar County, Mississippi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    The Salmon Site (SS), formerly the Tatum Dome Test Site, located in Mississippi was the site of two nuclear and two gas explosion tests conducted between 1964 and 1970. A consequence of these testing activities is that radionuclides were released into the salt dome, where they are presently contained. During reentry drilling and other site activities, incidental liquid and solid wastes that contained radioactivity were generated, resulting in some soil, ground water and equipment contamination. As part of the remedial investigation effort, a Baseline Ecological Risk Assessment was conducted at the SS. The purpose is to gauge ecological and other environmental impacts attributable to past activities at the former test facility. The results of this facility-specific baseline risk assessment are presented in this document.

  6. 40 CFR 80.910 - How does a refiner or importer apply for a toxics baseline?

    Science.gov (United States)

    2010-07-01

    ... for a toxics baseline? 80.910 Section 80.910 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Toxics Baseline Determination § 80.910 How does a refiner or importer apply for a toxics baseline? (a)(1) A refiner or importer...

  7. Digital curation of research data experiences of a baseline study in Germany

    CERN Document Server

    Strathmann, Stefan; Oßwald, Achim; Ludwig, Jens

    2013-01-01

    The relevance of research data today and for the future is well documented and discussed, in Germany as well as internationally. Ensuring that research data are accessible, sharable, and re-usable over time is increasingly becoming an essential task for researchers and research infrastructure institutions. Some reasons for this development include the following: - research data are documented and could therefore be validated - research data could be the basis for new research questions - research data could be re-analyzed by using innovative digital methods - research data could be used by other disciplines Therefore, it is essential that research data are curated, which means they are kept accessible and interpretable over time. In Germany, a baseline study was undertaken analyzing the situation in eleven research disciplines in 2012. The results were then published in a German-language edition. To address an international audience, the German-language edition of the study has been translated and abridged. T...

  8. NETWORK DESIGN IN CLOSE-RANGE PHOTOGRAMMETRY WITH SHORT BASELINE IMAGES

    Directory of Open Access Journals (Sweden)

    L. Barazzetti

    2017-08-01

    Full Text Available The avaibility of automated software for image-based 3D modelling has changed the way people acquire images for photogrammetric applications. Short baseline images are required to match image points with SIFT-like algorithms, obtaining more images than those necessary for “old fashioned” photogrammetric projects based on manual measurements. This paper describes some considerations on network design for short baseline image sequences, especially on precision and reliability of bundle adjustment. Simulated results reveal that the large number of 3D points used for image orientation has very limited impact on network precision.

  9. A fully automated algorithm of baseline correction based on wavelet feature points and segment interpolation

    Science.gov (United States)

    Qian, Fang; Wu, Yihui; Hao, Peng

    2017-11-01

    Baseline correction is a very important part of pre-processing. Baseline in the spectrum signal can induce uneven amplitude shifts across different wavenumbers and lead to bad results. Therefore, these amplitude shifts should be compensated before further analysis. Many algorithms are used to remove baseline, however fully automated baseline correction is convenient in practical application. A fully automated algorithm based on wavelet feature points and segment interpolation (AWFPSI) is proposed. This algorithm finds feature points through continuous wavelet transformation and estimates baseline through segment interpolation. AWFPSI is compared with three commonly introduced fully automated and semi-automated algorithms, using simulated spectrum signal, visible spectrum signal and Raman spectrum signal. The results show that AWFPSI gives better accuracy and has the advantage of easy use.

  10. Despite worse baseline status depressed patients achieved outcomes similar to those in nondepressed patients after surgery for cervical deformity.

    Science.gov (United States)

    Poorman, Gregory W; Passias, Peter G; Horn, Samantha R; Frangella, Nicholas J; Daniels, Alan H; Hamilton, D Kojo; Kim, Hanjo; Sciubba, Daniel; Diebo, Bassel G; Bortz, Cole A; Segreto, Frank A; Kelly, Michael P; Smith, Justin S; Neuman, Brian J; Shaffrey, Christopher I; LaFage, Virginie; LaFage, Renaud; Ames, Christopher P; Hart, Robert; Mundis, Gregory M; Eastlack, Robert

    2017-12-01

    OBJECTIVE Depression and anxiety have been demonstrated to have negative impacts on outcomes after spine surgery. In patients with cervical deformity (CD), the psychological and physiological burdens of the disease may overlap without clear boundaries. While surgery has a proven record of bringing about significant pain relief and decreased disability, the impact of depression and anxiety on recovery from cervical deformity corrective surgery has not been previously reported on in the literature. The purpose of the present study was to determine the effect of depression and anxiety on patients' recovery from and improvement after CD surgery. METHODS The authors conducted a retrospective review of a prospective, multicenter CD database. Patients with a history of clinical depression, in addition to those with current self-reported anxiety or depression, were defined as depressed (D group). The D group was compared with nondepressed patients (ND group) with a similar baseline deformity determined by propensity score matching of the cervical sagittal vertical axis (cSVA). Baseline demographic, comorbidity, clinical, and radiographic data were compared among patients using t-tests. Improvement of symptoms was recorded at 3 months, 6 months, and 1 year postoperatively. All health-related quality of life (HRQOL) scores collected at these follow-up time points were compared using t-tests. RESULTS Sixty-six patients were matched for baseline radiographic parameters: 33 with a history of depression and/or current depression, and 33 without. Depressed patients had similar age, sex, race, and radiographic alignment: cSVA, T-1 slope minus C2-7 lordosis, SVA, and T-1 pelvic angle (p > 0.05). Compared with nondepressed individuals, depressed patients had a higher incidence of osteoporosis (21.2% vs 3.2%, p = 0.028), rheumatoid arthritis (18.2% vs 3.2%, p = 0.012), and connective tissue disorders (18.2% vs 3.2%, p = 0.012). At baseline, the D group had greater neck pain (7.9 of

  11. Quantification of baseline pupillary response and task-evoked pupillary response during constant and incremental task load.

    Science.gov (United States)

    Mosaly, Prithima R; Mazur, Lukasz M; Marks, Lawrence B

    2017-10-01

    The methods employed to quantify the baseline pupil size and task-evoked pupillary response (TEPR) may affect the overall study results. To test this hypothesis, the objective of this study was to assess variability in baseline pupil size and TEPR during two basic working memory tasks: constant load of 3-letters memorisation-recall (10 trials), and incremental load memorisation-recall (two trials of each load level), using two commonly used methods (1) change from trail/load specific baseline, (2) change from constant baseline. Results indicated that there was a significant shift in baseline between the trails for constant load, and between the load levels for incremental load. The TEPR was independent of shifts in baseline using method 1 only for constant load, and method 2 only for higher levels of incremental load condition. These important findings suggest that the assessment of both the baseline and methods to quantify TEPR are critical in ergonomics application, especially in studies with small number of trials per subject per condition. Practitioner Summary: Quantification of TEPR can be affected by shifts in baseline pupil size that are most likely affected by non-cognitive factors when other external factors are kept constant. Therefore, quantification methods employed to compute both baseline and TEPR are critical in understanding the information processing of humans in practical ergonomics settings.

  12. Baseline risk and marginal willingness to pay for health risk reduction.

    Science.gov (United States)

    Gerking, Shelby; Adamowicz, Wiktor; Dickie, Mark; Veronesi, Marcella

    2017-01-01

    Empirical results presented in this paper suggest that parents' marginal willingness to pay (MWTP) for a reduction in morbidity risk from heart disease is inversely related to baseline risk (i.e., the amount of risk initially faced) both for themselves and for their children. For instance, a 40% reduction from the mean of baseline risk results in an increase in MWTP by 70% or more. Thus, estimates of monetary benefits of public programs to reduce heart disease risk would be understated if the standard practice is followed of evaluating MWTP at initial risk levels and then multiplying this value by the number of cases avoided. Estimates are supported by: (1) unique quantitative information on perceptions of the risk of getting heart disease that allow baseline risk to be defined at an individual level and (2) improved econometric procedures to control for well-known difficulties associated with stated preference data.

  13. Nonintrusive methodology for wellness baseline profiling

    Science.gov (United States)

    Chung, Danny Wen-Yaw; Tsai, Yuh-Show; Miaou, Shaou-Gang; Chang, Walter H.; Chang, Yaw-Jen; Chen, Shia-Chung; Hong, Y. Y.; Chyang, C. S.; Chang, Quan-Shong; Hsu, Hon-Yen; Hsu, James; Yao, Wei-Cheng; Hsu, Ming-Sin; Chen, Ming-Chung; Lee, Shi-Chen; Hsu, Charles; Miao, Lidan; Byrd, Kenny; Chouikha, Mohamed F.; Gu, Xin-Bin; Wang, Paul C.; Szu, Harold

    2007-04-01

    We develop an accumulatively effective and affordable set of smart pair devices to save the exuberant expenditure for the healthcare of aging population, which will not be sustainable when all the post-war baby boomers retire (78 millions will cost 1/5~1/4 GDP in US alone). To design an accessible test-bed for distributed points of homecare, we choose two exemplars of the set to demonstrate the possibility of translation of modern military and clinical know-how, because two exemplars share identically the noninvasive algorithm adapted to the Smart Sensor-pairs for the real world persistent surveillance. Currently, the standard diagnoses for malignant tumors and diabetes disorders are blood serum tests, X-ray CAT scan, and biopsy used sometime in the physical checkup by physicians as cohort-average wellness baselines. The loss of the quality of life in making second careers productive may be caused by the missing of timeliness for correct diagnoses and easier treatments, which contributes to the one quarter of human errors generating the lawsuits against physicians and hospitals, which further escalates the insurance cost and wasteful healthcare expenditure. Such a vicious cycle should be entirely eliminated by building an "individual diagnostic aids (IDA)," similar to the trend of personalized drug, developed from daily noninvasive intelligent databases of the "wellness baseline profiling (WBP)". Since our physiology state undulates diurnally, the Nyquist anti-aliasing theory dictates a minimum twice-a-day sampling of the WBP for the IDA, which must be made affordable by means of noninvasive, unsupervised and unbiased methodology at the convenience of homes. Thus, a pair of military infrared (IR) spectral cameras has been demonstrated for the noninvasive spectrogram ratio test of the spontaneously emitted thermal radiation from a normal human body at 37°C temperature. This invisible self-emission spreads from 3 microns to 12 microns of the radiation wavelengths

  14. Patient baseline interpersonal problems as moderators of outcome in two psychotherapies for bulimia nervosa.

    Science.gov (United States)

    Gomez Penedo, Juan Martin; Constantino, Michael J; Coyne, Alice E; Bernecker, Samantha L; Smith-Hansen, Lotte

    2018-01-19

    We tested an aptitude by treatment interaction; namely, whether patients' baseline interpersonal problems moderated the comparative efficacy of cognitive-behavioral therapy (CBT) vs. interpersonal psychotherapy (IPT) for bulimia nervosa (BN). Data derived from a randomized-controlled trial. Patients reported on their interpersonal problems at baseline; purge frequency at baseline, midtreatment, and posttreatment; and global eating disorder severity at baseline and posttreatment. We estimated the rate of change in purge frequency across therapy, and the likelihood of attaining clinically meaningful improvement (recovery) in global eating disorder severity by posttreatment. We then tested the interpersonal problem by treatment interactions as predictors of both outcomes. Patients with more baseline overly communal/friendly problems showed steeper reduction in likelihood of purging when treated with CBT vs. IPT. Patients with more problems of being under communal/cold had similar reductions in likelihood of purging across both treatments. Patients with more baseline problems of being overly agentic were more likely to recover when treated with IPT vs. CBT, whereas patients with more problems of being under agentic were more likely to recover when treated with CBT vs. IPT. Interpersonal problems related to communion and agency may inform treatment fit among two empirically supported therapies for BN.

  15. A simple technique investigating baseline heterogeneity helped to eliminate potential bias in meta-analyses.

    Science.gov (United States)

    Hicks, Amy; Fairhurst, Caroline; Torgerson, David J

    2018-03-01

    To perform a worked example of an approach that can be used to identify and remove potentially biased trials from meta-analyses via the analysis of baseline variables. True randomisation produces treatment groups that differ only by chance; therefore, a meta-analysis of a baseline measurement should produce no overall difference and zero heterogeneity. A meta-analysis from the British Medical Journal, known to contain significant heterogeneity and imbalance in baseline age, was chosen. Meta-analyses of baseline variables were performed and trials systematically removed, starting with those with the largest t-statistic, until the I 2 measure of heterogeneity became 0%, then the outcome meta-analysis repeated with only the remaining trials as a sensitivity check. We argue that heterogeneity in a meta-analysis of baseline variables should not exist, and therefore removing trials which contribute to heterogeneity from a meta-analysis will produce a more valid result. In our example none of the overall outcomes changed when studies contributing to heterogeneity were removed. We recommend routine use of this technique, using age and a second baseline variable predictive of outcome for the particular study chosen, to help eliminate potential bias in meta-analyses. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Adolescents' sleep in low-stress and high-stress (exam) times: a prospective quasi-experiment.

    Science.gov (United States)

    Dewald, Julia F; Meijer, Anne Marie; Oort, Frans J; Kerkhof, Gerard A; Bögels, Susan M

    2014-01-01

    This prospective quasi-experiment (N = 175; mean age = 15.14 years) investigates changes in adolescents' sleep from low-stress (regular school week) to high-stress times (exam week), and examines the (moderating) role of chronic sleep reduction, baseline stress, and gender. Sleep was monitored over three consecutive weeks using actigraphy. Adolescents' sleep was more fragmented during the high-stress time than during the low-stress time, meaning that individuals slept more restless during stressful times. However, sleep efficiency, total sleep time, and sleep onset latency remained stable throughout the three consecutive weeks. High chronic sleep reduction was related to later bedtimes, later sleep start times, later sleep end times, later getting up times, and more time spent in bed. Furthermore, low chronic sleep reduction and high baseline stress levels were related to more fragmented sleep during stressful times. This study shows that stressful times can have negative effects on adolescents' sleep fragmentation, especially for adolescents with low chronic sleep reduction or high baseline stress levels.

  17. Motivation and Barriers for Leisure-Time Physical Activity in Socioeconomically Disadvantaged Women.

    Science.gov (United States)

    Santos, Inês; Ball, Kylie; Crawford, David; Teixeira, Pedro J

    2016-01-01

    The aim of this study was to examine cross-sectional and longitudinal associations between motivation and barriers for physical activity, and physical activity behavior in women living in socioeconomic disadvantage. This study also examined whether weight control intentions moderate those associations. Data from 1664 women aged 18-46 years was collected at baseline and three-year follow-up as part of the Resilience for Eating and Activity Despite Inequality study. In mail-based surveys, women reported sociodemographic and neighborhood environmental characteristics, intrinsic motivation, goals and perceived family barriers to be active, weight control intentions and leisure-time physical activity (assessed through the IPAQ-L). Linear regression models assessed the association of intrinsic motivation, goals and barriers with physical activity at baseline and follow-up, adjusting for environmental characteristics and also physical activity at baseline (for longitudinal analyses), and the moderating effects of weight control intentions were examined. Intrinsic motivation and, to a lesser extent, appearance and relaxation goals for being physically active were consistently associated with leisure-time physical activity at baseline and follow-up. Perceived family barriers, health, fitness, weight and stress relief goals were associated with leisure-time physical activity only at baseline. Moderated regression analyses revealed that weight control intentions significantly moderated the association between weight goals and leisure-time physical activity at baseline (β = 0.538, 99% CI = 0.057, 0.990) and between intrinsic motivation and leisure-time physical activity at follow-up (β = 0.666, 99% CI = 0.188, 1.145). For women actively trying to control their weight, intrinsic motivation was significantly associated with leisure-time physical activity at follow-up (β = 0.184, 99% CI = 0.097, 0.313). Results suggest that, especially in women trying to control their weight

  18. Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

    International Nuclear Information System (INIS)

    Klepper, C.C.; Biewer, T.M.; Marcus, C.; Graves, V.B.; Andrew, P.; Hughes, S.; Gardner, W.L.

    2017-01-01

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for /textasciitilde 1 s response time from the sensor cluster [1].

  19. Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

    Science.gov (United States)

    Klepper, C. C.; Biewer, T. M.; Marcus, C.; Andrew, P.; Gardner, W. L.; Graves, V. B.; Hughes, S.

    2017-10-01

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \\textasciitilde 1 s response time from the sensor cluster [1].

  20. Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Biewer, Theodore M. [ORNL; Marcus, Chris [ORNL; Klepper, C Christopher [ORNL; Andrew, Philip [ITER Organization, Cadarache, France; Gardner, W. L. [United States ITER Project Office; Graves, Van B. [ORNL; Hughes, Shaun [ITER Organization, Saint Paul Lez Durance, France

    2017-10-01

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \\textasciitilde 1 s response time from the sensor cluster [1].

  1. Could baseline establishment be counterproductive for emissions reduction? Insights from Vietnam’s building sector

    DEFF Research Database (Denmark)

    Henrysson, Maryna; Lütken, Søren; Puig, Daniel

    2017-01-01

    Mitigation Actions (NAMAs) to illustrate institutional dynamics, nationally and transnationally, as well as to question whether demands for baseline setting achieve the ideal trade-off between actual GHG emissions reduction and institutionalized demands for accountability. The analysis reveals that......, it argues for the abolition of baselines in favour of adequate monitoring and evaluation, from the perspective that requirement for deviation from fictitious baselines is unproductive and only serves an international techno-managerial discourse....

  2. BASLIKO. A program for baseline-correction of earthquake-accelerograms

    International Nuclear Information System (INIS)

    Koschmieder, D.; Altes, J.

    1978-12-01

    In the following report a program for baseline-correction of earthquake-accelerograms is presented. By using this program errors in curves, which occur in using the chronographs and digitizers, are eliminated. (orig.) [de

  3. High baseline activity in inferior temporal cortex improves neural and behavioral discriminability during visual categorization

    Directory of Open Access Journals (Sweden)

    Nazli eEmadi

    2014-11-01

    Full Text Available Spontaneous firing is a ubiquitous property of neural activity in the brain. Recent literature suggests that this baseline activity plays a key role in perception. However, it is not known how the baseline activity contributes to neural coding and behavior. Here, by recording from the single neurons in the inferior temporal cortex of monkeys performing a visual categorization task, we thoroughly explored the relationship between baseline activity, the evoked response, and behavior. Specifically we found that a low-frequency (< 8 Hz oscillation in the spike train, prior and phase-locked to the stimulus onset, was correlated with increased gamma power and neuronal baseline activity. This enhancement of the baseline activity was then followed by an increase in the neural selectivity and the response reliability and eventually a higher behavioral performance.

  4. Determinants of Change in Children’s Sedentary Time

    Science.gov (United States)

    Atkin, Andrew J.; Corder, Kirsten; Ekelund, Ulf; Wijndaele, Katrien; Griffin, Simon J.; van Sluijs, Esther M. F.

    2013-01-01

    Background Understanding the determinants of sedentary time during childhood contributes to the development of effective intervention programmes. Purpose To examine family and home-environmental determinants of 1-year change in objectively measured sedentary time after-school and at the weekend. Methods Participants wore accelerometers at baseline and 1 year later. Longitudinal data for after-school and weekend analyses were available for 854 (41.5%male, mean±SD age 10.2±0.3years) and 718 (41.8%male, age 10.2±0.3years) participants. Information on 26 candidate determinants, including socioeconomic status (SES), availability of electronic media and parental rules for sedentary behaviours was self-reported by children or their parents at baseline. Change in the proportion of registered time spent sedentary was used as the outcome variable in multi-level linear regression models, adjusted for age, sex, body mass index and baseline sedentary time. Simple and multiple models were run and interactions with sex explored. Results Children from higher socioeconomic status families exhibited greater increases in after-school (beta; 95% CI for change in % time spent sedentary 1.02; 0.37, 1.66) and weekend (1.42; 0.65, 2.18) sedentary time. Smaller increases in after-school sedentary time were observed in children with more siblings (−1.00; −1.69, −0.30), greater availability of electronic media (−0.81; −1.29, −0.33) and, for boys, more frequent family visits to the park (−1.89; −3.28, −0.51) and family participation in sport (−1.28; −2.54, −0.02). Greater maternal weekend screen-time (0.45; 0.08, 0.83) and, in girls, greater parental restriction on playing outside (0.91; 0.08, 1.74) were associated with larger increases in weekend sedentary time. The analytical sample was younger, more likely to be female, had lower BMI and was of higher SES than the original baseline sample. Conclusions Intervention strategies aimed at reducing parents’ weekend

  5. Spectrometer Baseline Control Via Spatial Filtering

    Science.gov (United States)

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  6. Neutrino physics with short baseline experiments

    International Nuclear Information System (INIS)

    Zimmerman, E.D.

    2006-01-01

    Neutrino physics with low- to medium-energy beams has progressed steadily over the last several years. Neutrino oscillation searches at short baseline (defined as 2 - -> 0.1eV 2 . One positive signal, from the LSND collaboration, exists and is being tested by the MiniBooNE experiment. Neutrino cross-section measurements are being made by MiniBooNE and K2K, which will be important for reducing systematic errors in present and future oscillation measurements. In the near future, dedicated cross- section experiments will begin operating at Fermilab. (author)

  7. Environmental Baseline File for National Transportation

    International Nuclear Information System (INIS)

    1999-01-01

    This Environmental Baseline File summarizes and consolidates information related to the national-level transportation of commercial spent nuclear fuel. Topics address include: shipments of commercial spent nuclear fuel based on mostly truck and mostly rail shipping scenarios; transportation routing for commercial spent nuclear fuel sites and DOE sites; radionuclide inventories for various shipping container capacities; transportation routing; populations along transportation routes; urbanized area population densities; the impacts of historical, reasonably foreseeable, and general transportation; state-level food transfer factors; Federal Guidance Report No. 11 and 12 radionuclide dose conversion factors; and national average atmospheric conditions

  8. Baseline scenarios of global environmental change

    International Nuclear Information System (INIS)

    Alcamo, J.; Kreileman, G.J.J.; Bollen, J.C.; Born, G.J. van den; Krol, M.S.; Toet, A.M.C.; Vries, H.J.M. de; Gerlagh, R.

    1996-01-01

    This paper presents three baseline scenarios of no policy action computed by the IMAGE2 model. These scenarios cover a wide range of coupled global change indicators, including: energy demand and consumption; food demand, consumption, and production; changes in land cover including changes in extent of agricultural land and forest; emissions of greenhouse gases and ozone precursors; and climate change and its impacts on sea level rise, crop productivity and natural vegetation. Scenario information is available for the entire world with regional and grid scale detail, and covers from 1970 to 2100. (author)

  9. New baseline correction algorithm for text-line recognition with bidirectional recurrent neural networks

    Science.gov (United States)

    Morillot, Olivier; Likforman-Sulem, Laurence; Grosicki, Emmanuèle

    2013-04-01

    Many preprocessing techniques have been proposed for isolated word recognition. However, recently, recognition systems have dealt with text blocks and their compound text lines. In this paper, we propose a new preprocessing approach to efficiently correct baseline skew and fluctuations. Our approach is based on a sliding window within which the vertical position of the baseline is estimated. Segmentation of text lines into subparts is, thus, avoided. Experiments conducted on a large publicly available database (Rimes), with a BLSTM (bidirectional long short-term memory) recurrent neural network recognition system, show that our baseline correction approach highly improves performance.

  10. S Plant Aggregate Area Management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document is prepared in support of an Aggregate Area Management Study of S Plant, 200 West Area, at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. It provides a technical baseline of the aggregate area and the results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC). This document is based on review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. This report describes the REDOX facility and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, underground tank farms designed for high-level liquid wastes, and the lines and encasements that connect them

  11. A baseline correction algorithm for Raman spectroscopy by adaptive knots B-spline

    International Nuclear Information System (INIS)

    Wang, Xin; Fan, Xian-guang; Xu, Ying-jie; Wang, Xiu-fen; He, Hao; Zuo, Yong

    2015-01-01

    The Raman spectroscopy technique is a powerful and non-invasive technique for molecular fingerprint detection which has been widely used in many areas, such as food safety, drug safety, and environmental testing. But Raman signals can be easily corrupted by a fluorescent background, therefore we presented a baseline correction algorithm to suppress the fluorescent background in this paper. In this algorithm, the background of the Raman signal was suppressed by fitting a curve called a baseline using a cyclic approximation method. Instead of the traditional polynomial fitting, we used the B-spline as the fitting algorithm due to its advantages of low-order and smoothness, which can avoid under-fitting and over-fitting effectively. In addition, we also presented an automatic adaptive knot generation method to replace traditional uniform knots. This algorithm can obtain the desired performance for most Raman spectra with varying baselines without any user input or preprocessing step. In the simulation, three kinds of fluorescent background lines were introduced to test the effectiveness of the proposed method. We showed that two real Raman spectra (parathion-methyl and colza oil) can be detected and their baselines were also corrected by the proposed method. (paper)

  12. ACE and UCP2 gene polymorphisms and their association with baseline and exercise-related changes in the functional performance of older adults

    Directory of Open Access Journals (Sweden)

    Justin W.L. Keogh

    2015-05-01

    Full Text Available Maintaining high levels of physical function is an important aspect of successful ageing. While muscle mass and strength contribute to functional performance in older adults, little is known about the possible genetic basis for the heterogeneity of physical function in older adults and in how older adults respond to exercise. Two genes that have possible roles in determining levels of muscle mass, strength and function in young and older adults are angiotensin-converting enzyme (ACE and mitochondrial uncoupling protein 2 (UCP2. This study examined whether polymorphisms in these two individual genes were associated with baseline functional performance levels and/or the training-related changes following exercise in previously untrained older adults. Five-eight Caucasian older adults (mean age 69.8 years with no recent history of resistance training enrolled in a 12 week program of resistance, balance and cardiovascular exercises aimed at improving functional performance. Performance in 6 functional tasks was recorded at baseline and after 12 weeks. Genomic DNA was assayed for the ACE intron 16 insertion/deletion (I/D and the UCP2 G-866A polymorphism. Baseline differences among genotype groups were tested using analysis of variance. Genotype differences in absolute and relative changes in physical function among the exercisers were tested using a general linear model, adjusting for age and gender. The genotype frequencies for each of the studied polymorphisms conformed to the Hardy-Weinberg equilibrium. The ACE I/D genotype was significantly associated with mean baseline measures of handgrip strength (II 30.9 ± 3.01 v. ID 31.7 ± 1.48 v. DD 29.3 ± 2.18 kg, p < 0.001, 8ft Up and Go time (II 6.45 ± 0.48 v. ID/DD 4.41 ± 0.19 s, p < 0.001 and 6 min walk distance (II 458 ± 28.7 v. ID/DD 546 ± 12.1m, p = 0.008. The UCP2 G-866A genotype was also associated with baseline 8ft Up and Go time (GG 5.45 ± 0.35 v. GA 4.47 ± 0.26 v. AA 3.89 ± 0.71 s, p

  13. 77 FR 23244 - Atmos Energy Colorado/Kansas Division; Notice of Revised Baseline Filing

    Science.gov (United States)

    2012-04-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-22-000] Atmos Energy Colorado/Kansas Division; Notice of Revised Baseline Filing Take notice that on April 10, 2012, Atmos Energy Colorado/Kansas Division (Atmos) filed a revised baseline filing of their Statement of Operating...

  14. 76 FR 2361 - Atmos Energy-Kentucky/Mid-States Division; Notice of Baseline Filing

    Science.gov (United States)

    2011-01-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-77-000] Atmos Energy--Kentucky/Mid-States Division; Notice of Baseline Filing January 5, 2011. Take notice that on December 30, 2010, Atmos Energy--Kentucky/Mid- States Division submitted a revised baseline filing of their...

  15. Baseline concentration of {sup 210}Po in Sargassum from the Northern Gulf

    Energy Technology Data Exchange (ETDEWEB)

    Uddin, S.; Bebhehani, M.; Talebi, L. [Kuwait Institute for Scientific Research (Kuwait)

    2014-07-01

    The concentration of the {sup 210}Po is of enormous interest because of its large contribution to the natural radiation dose received by marine organisms and human populations consuming seafood. In fact natural {sup 210}Po is responsible for higher radiation doses to humans consuming marine products than is plutonium and other man-made radionuclides. Many marine organisms are capable of concentrating {sup 210}Po in their tissues. {sup 210}Po is an alpha emitter in the {sup 238}U series, with 138-d half-life, that is supplied to seawater from atmospheric inputs and river runoff, however, the main source of {sup 210}Po in the environment is {sup 222}Rn exhalation from the ground. Assessing the impact of radionuclides in the environment requires the establishment of baseline levels in the environmental compartments. The objective of this study was to establish baseline levels in Sargassum. Two most common species of Sargassum found in the northern Gulf were analysed for {sup 210}Po. These macro-algae were collected from three different locations during January 2013. This study sets the baseline for {sup 210}Po concentration in northern Gulf, {sup 210}Po is absorbed from water and concentrated by Phytoplankton and macro-algae. This concentrated {sup 210}Po can then be passed along to the next trophic level of the marine food web. The {sup 210}Po concentration measured in Sargassum boveanum (4.405 - 4.952 BqKg{sup -1}) was significantly higher (p>0.084) than Sargassum oligocystum (3.838 - 4.358 BqKg{sup -1}). The {sup 210}Po concentration in these seaweeds from the Arabian/Persian Gulf were substantially lower than those found in various Phytoplankton and macro-algae species from other regions; this may be due to the lower background {sup 210}Po concentration in the Kuwait marine waters (0.282 - 0.382 mBq l{sup -1}). The {sup 210}Po concentrations in seawater measured at the 3 stations during January 2013 were less than those reported previously from the same region

  16. Contribution of BeiDou satellite system for long baseline GNSS measurement in Indonesia

    Science.gov (United States)

    Gumilar, I.; Bramanto, B.; Kuntjoro, W.; Abidin, H. Z.; Trihantoro, N. F.

    2018-05-01

    The demand for more precise positioning method using GNSS (Global Navigation Satellite System) in Indonesia continue to rise. The accuracy of GNSS positioning depends on the length of baseline and the distribution of observed satellites. BeiDou Navigation Satellite System (BDS) is a positioning system owned by China that operating in Asia-Pacific region, including Indonesia. This research aims to find out the contribution of BDS in increasing the accuracy of long baseline static positioning in Indonesia. The contributions are assessed by comparing the accuracy of measurement using only GPS (Global Positioning System) and measurement using the combination of GPS and BDS. The data used is 5 days of GPS and BDS measurement data for baseline with 120 km in length. The software used is open-source RTKLIB and commercial software Compass Solution. This research will explain in detail the contribution of BDS to the accuracy of position in long baseline static GNSS measurement.

  17. Baseline disability in activities of daily living predicts dementia risk even after controlling for baseline global cognitive ability and depressive symptoms.

    Science.gov (United States)

    Fauth, Elizabeth B; Schwartz, Sarah; Tschanz, Joann T; Østbye, Truls; Corcoran, Christopher; Norton, Maria C

    2013-06-01

    Late-life disability in activities of daily living (ADL) is theorized to be driven by underlying cognitive and/or physical impairment, interacting with psychological and environmental factors. Although we expect that cognitive deficits would explain associations between ADL disability and dementia risk, the current study examined ADL as a predictor of future dementia after controlling for global cognitive status. The population-based Cache County Memory Study (N = 3547) assessed individuals in four triennial waves (average age 74.9 years, years of education 13.36 years; 57.9% were women). Cox proportional hazards regression models assessed whether baseline ADL disability (presence of 2+ Instrumental ADL and/or 1+ Personal ADL) predicted incident dementia after controlling for APOE status, gender, age, baseline cognitive ability (Modified Mini-mental State Exam, 3MS-R; adjusted for education level), and baseline depressive symptoms (Diagnostic Interview Schedule). Over the course of study, 571 cases of incident dementia were identified through in-depth cognitive assessment, ending in expert consensus diagnosis. Results from Cox models suggest that ADL disability is a statistically significant predictor of incident dementia (adjusted hazard ratio = 1.83, p controlling for covariates. Findings suggest that ADL disability offers unique contributions in risk for incident dementia, even after controlling for global cognitive status. We discuss how physical impairment and executive function may play important roles in this relationship, and how ADL is useful, not just a diagnostic tool at, or after dementia onset, but also as a risk factor for future dementia, even in individuals not impaired on global cognitive tests. Copyright © 2012 John Wiley & Sons, Ltd.

  18. The effect of baseline testosterone on the efficacy of degarelix and leuprolide

    DEFF Research Database (Denmark)

    Damber, Jan-Erik; Tammela, Teuvo L J; Iversen, Peter

    2012-01-01

    To investigate the effects of baseline testosterone on testosterone control and prostate-specific antigen (PSA) suppression using data from a phase III trial (CS21) comparing degarelix and leuprolide in prostate cancer.......To investigate the effects of baseline testosterone on testosterone control and prostate-specific antigen (PSA) suppression using data from a phase III trial (CS21) comparing degarelix and leuprolide in prostate cancer....

  19. The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges.

    Science.gov (United States)

    Eide, Per K; Bakken, André

    2011-08-22

    The monitoring of intracranial pressure (ICP) has a crucial role in the surveillance of patients with brain injury. During long-term monitoring of ICP, we have seen spontaneous shifts in baseline pressure (ICP sensor zero point), which are of technical and not physiological origin. The aim of the present study was to explore whether or not baseline pressures of ICP sensors can be affected by electrostatics discharges (ESD's), when ESD's are delivered at clinically relevant magnitudes. We performed bench-testing of a set of commercial ICP sensors. In our experimental setup, the ICP sensor was placed in a container with 0.9% NaCl solution. A test person was charged 0.5-10 kV, and then delivered ESD's to the sensor by touching a metal rod that was located in the container. The continuous pressure signals were recorded continuously before/after the ESD's, and the pressure readings were stored digitally using a computerized system A total of 57 sensors were tested, including 25 Codman ICP sensors and 32 Raumedic sensors. When charging the test person in the range 0.5-10 kV, typically ESD's in the range 0.5-5 kV peak pulse were delivered to the ICP sensor. Alterations in baseline pressure ≥ 2 mmHg was seen in 24 of 25 (96%) Codman sensors and in 17 of 32 (53%) Raumedic sensors. Lasting changes in baseline pressure > 10 mmHg that in the clinical setting would affect patient management, were seen frequently for both sensor types. The changes in baseline pressure were either characterized by sudden shifts or gradual drifts in baseline pressure. The baseline pressures of commercial solid ICP sensors can be altered by ESD's at discharge magnitudes that are clinically relevant. Shifts in baseline pressure change the ICP levels visualised to the physician on the monitor screen, and thereby reveal wrong ICP values, which likely represent a severe risk to the patient.

  20. [Diagnostic value of baseline serum luteinizing hormone level for central precocious puberty in girls].

    Science.gov (United States)

    Ou-Yang, Li-Xue; Yang, Fan

    2017-07-01

    To evaluate the diagnostic value of baseline serum luteinizing hormone (LH) level for central precocious puberty (CPP) in girls. A total of 279 girls with precocious puberty were subjected to assessment of growth and development, bone age determination, baseline LH test, and follicle-stimulating hormone (FSH) test, gonadotropin-releasing hormone stimulation test, and other related examinations. Of the 279 patients, 175 were diagnosed with CPP and 104 with premature thelarche (PT). The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of baseline LH and FSH levels and their peak levels for CPP, and the correlation between the baseline LH level and the peak LH level was analyzed. The CPP group had significantly higher bone age, baseline LH and FSH levels, peak LH and FSH levels, and ratio of peak LH level to peak FSH level than the PT group (Pbaseline LH level and peak LH level had good diagnostic values for CPP. Among the three bone age subgroups in the CPP group (7.0-9.0 years, 9.0-11.0 years, and >11.0 years), baseline LH level showed the best diagnostic value in the >11.0 years subgroup, with the largest area under the ROC curve. At a baseline LH level of 0.45 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 66.7% and 80% respectively, for the diagnosis of CPP. At a peak LH level of 9.935 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 74.8% and 100% respectively, for the diagnosis of CPP. The baseline LH level was positively correlated with the peak LH level (r=0.440, PBaseline LH level can be used as an primary screening index for the diagnosis of CPP. It has a certain diagnostic value for CPP at different bone ages, and may be used as a monitoring index during the treatment and follow-uP.

  1. Baseline response rates affect resistance to change.

    Science.gov (United States)

    Kuroda, Toshikazu; Cook, James E; Lattal, Kennon A

    2018-01-01

    The effect of response rates on resistance to change, measured as resistance to extinction, was examined in two experiments. In Experiment 1, responding in transition from a variable-ratio schedule and its yoked-interval counterpart to extinction was compared with pigeons. Following training on a multiple variable-ratio yoked-interval schedule of reinforcement, in which response rates were higher in the former component, reinforcement was removed from both components during a single extended extinction session. Resistance to extinction in the yoked-interval component was always either greater or equal to that in the variable-ratio component. In Experiment 2, resistance to extinction was compared for two groups of rats that exhibited either high or low response rates when maintained on identical variable-interval schedules. Resistance to extinction was greater for the lower-response-rate group. These results suggest that baseline response rate can contribute to resistance to change. Such effects, however, can only be revealed when baseline response rate and reinforcement rate are disentangled (Experiments 1 and 2) from the more usual circumstance where the two covary. Furthermore, they are more cleanly revealed when the programmed contingencies controlling high and low response rates are identical, as in Experiment 2. © 2017 Society for the Experimental Analysis of Behavior.

  2. Integrated Baseline Review (IBR) Handbook

    Science.gov (United States)

    Fleming, Jon F.; Kehrer, Kristen C.

    2016-01-01

    The purpose of this handbook is intended to be a how-to guide to prepare for, conduct, and close-out an Integrated Baseline Review (IBR). It discusses the steps that should be considered, describes roles and responsibilities, tips for tailoring the IBR based on risk, cost, and need for management insight, and provides lessons learned from past IBRs. Appendices contain example documentation typically used in connection with an IBR. Note that these appendices are examples only, and should be tailored to meet the needs of individual projects and contracts. Following the guidance in this handbook will help customers and suppliers preparing for an IBR understand the expectations of the IBR, and ensure that the IBR meets the requirements for both in-house and contract efforts.

  3. Baselines For Land-Use Change In The Tropics: Application ToAvoided Deforestation Projects

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Sandra; Hall, Myrna; Andrasko, Ken; Ruiz, Fernando; Marzoli, Walter; Guerrero, Gabriela; Masera, Omar; Dushku, Aaron; Dejong,Ben; Cornell, Joseph

    2007-06-01

    Although forest conservation activities particularly in thetropics offer significant potential for mitigating carbon emissions,these types of activities have faced obstacles in the policy arena causedby the difficulty in determining key elements of the project cycle,particularly the baseline. A baseline for forest conservation has twomain components: the projected land-use change and the correspondingcarbon stocks in the applicable pools such as vegetation, detritus,products and soil, with land-use change being the most difficult toaddress analytically. In this paper we focus on developing and comparingthree models, ranging from relatively simple extrapolations of pasttrends in land use based on simple drivers such as population growth tomore complex extrapolations of past trends using spatially explicitmodels of land-use change driven by biophysical and socioeconomicfactors. The three models of the latter category used in the analysis atregional scale are The Forest Area Change (FAC) model, the Land Use andCarbon Sequestration (LUCS) model, and the Geographical Modeling (GEOMOD)model. The models were used to project deforestation in six tropicalregions that featured different ecological and socioeconomic conditions,population dynamics, and uses of the land: (1) northern Belize; (2) SantaCruz State, Bolivia; (3) Parana State in Brazil; (4) Campeche, Mexico;(5) Chiapas, Mexico; and (6) Michoacan, Mexico. A comparison of all modeloutputs across all six regions shows that each model produced quitedifferent deforestation baseline. In general, the simplest FAC model,applied at the national administrative-unit scale, projected the highestamount of forest loss (four out of six) and the LUCS model the leastamount of loss (four out of five). Based on simulations of GEOMOD, wefound that readily observable physical and biological factors as well asdistance to areas of past disturbance were each about twice as importantas either sociological/demographic or economic

  4. Early antihypertensive treatment and clinical outcomes in acute ischemic stroke: subgroup analysis by baseline blood pressure.

    Science.gov (United States)

    He, William J; Zhong, Chongke; Xu, Tan; Wang, Dali; Sun, Yingxian; Bu, Xiaoqing; Chen, Chung-Shiuan; Wang, Jinchao; Ju, Zhong; Li, Qunwei; Zhang, Jintao; Geng, Deqin; Zhang, Jianhui; Li, Dong; Li, Yongqiu; Yuan, Xiaodong; Zhang, Yonghong; Kelly, Tanika N

    2018-06-01

    We studied the effect of early antihypertensive treatment on death, major disability, and vascular events among patients with acute ischemic stroke according to their baseline SBP. We randomly assigned 4071 acute ischemic stroke patients with SBP between 140 and less than 220 mmHg to receive antihypertensive treatment or to discontinue all antihypertensive medications during hospitalization. A composite primary outcome of death and major disability and secondary outcomes were compared between treatment and control stratified by baseline SBP levels of less than 160, 160-179, and at least 180 mmHg. At 24 h after randomization, differences in SBP reductions were 8.8, 8.6 and 7.8 mmHg between the antihypertensive treatment and control groups among patients with baseline SBP less than 160, 160-179, and at least 180 mmHg, respectively (P baseline SBP subgroups on death (P = 0.02): odds ratio (95% CI) of 2.42 (0.74-7.89) in patients with baseline SBP less than 60 mmHg and 0.34 (0.11-1.09) in those with baseline SBP at least 180 mmHg. At the 3-month follow-up, the primary and secondary clinical outcomes were not significantly different between the treatment and control groups by baseline SBP levels. Early antihypertensive treatment had a neutral effect on clinical outcomes among acute ischemic stroke patients with various baseline SBP levels. Future clinical trials are warranted to test BP-lowering effects in acute ischemic stroke patients by baseline SBP levels. ClinicalTrials.gov Identifier: NCT01840072.

  5. 75 FR 26746 - ONEOK Westex Transmission, L.L.C.; Notice of Baseline Filing

    Science.gov (United States)

    2010-05-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-19-000] ONEOK Westex Transmission, L.L.C.; Notice of Baseline Filing May 5, 2010. Take notice that on April 29, 2010, ONEOK Westex Transmission, L.L.C. submitted its baseline filing of its Statement of Operating Conditions for transportation...

  6. Influence of Baseline Diastolic Blood Pressure on Effects of Intensive Compared With Standard Blood Pressure Control.

    Science.gov (United States)

    Beddhu, Srinivasan; Chertow, Glenn M; Cheung, Alfred K; Cushman, William C; Rahman, Mahboob; Greene, Tom; Wei, Guo; Campbell, Ruth C; Conroy, Margaret; Freedman, Barry I; Haley, William; Horwitz, Edward; Kitzman, Dalane; Lash, James; Papademetriou, Vasilios; Pisoni, Roberto; Riessen, Erik; Rosendorff, Clive; Watnick, Suzanne G; Whittle, Jeffrey; Whelton, Paul K

    2018-01-09

    In individuals with a low diastolic blood pressure (DBP), the potential benefits or risks of intensive systolic blood pressure (SBP) lowering are unclear. SPRINT (Systolic Blood Pressure Intervention Trial) was a randomized controlled trial that compared the effects of intensive (target baseline DBP. Mean baseline SBP and DBP were 139.7±15.6 and 78.1±11.9 mm Hg, respectively. Regardless of the randomized treatment, baseline DBP had a U-shaped association with the hazard of the primary cardiovascular disease outcome. However, the effects of the intensive SBP intervention on the primary outcome were not influenced by baseline DBP level ( P for interaction=0.83). The primary outcome hazard ratio for intensive versus standard treatment was 0.78 (95% confidence interval, 0.57-1.07) in the lowest DBP quintile (mean baseline DBP, 61±5 mm Hg) and 0.74 (95% confidence interval, 0.61-0.90) in the upper 4 DBP quintiles (mean baseline DBP, 82±9 mm Hg), with an interaction P value of 0.78. Results were similar for all-cause death and kidney events. Low baseline DBP was associated with increased risk of cardiovascular disease events, but there was no evidence that the benefit of the intensive SBP lowering differed by baseline DBP. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01206062. © 2017 American Heart Association, Inc.

  7. Baseline drift effect on the performance of neutron and γ ray discrimination using frequency gradient analysis

    International Nuclear Information System (INIS)

    Liu Guofu; Luo Xiaoliang; Yang Jun; Lin Cunbao; Hu Qingqing; Peng Jinxian

    2013-01-01

    Frequency gradient analysis (FGA) effectively discriminates neutrons and γ rays by examining the frequency-domain features of the photomultiplier tube anode signal. This approach is insensitive to noise but is inevitably affected by the baseline drift similar to other pulse shape discrimination methods. The baseline drift effect is attributed to factors such as power line fluctuation, dark current, noise disturbances, hum, and pulse tail in front-end electronics. This effect needs to be elucidated and quantified before the baseline shift can be estimated and removed from the captured signal. Therefore, the effect of baseline shift on the discrimination performance of neutrons and γ rays with organic scintillation detectors using FGA is investigated in this paper. The relationship between the baseline shift and discrimination parameters of FGA is derived and verified by an experimental system consisting of an americium—beryllium source, a BC501A liquid scintillator detector, and a 5 GSample/s 8-bit oscilloscope. The theoretical and experimental results both show that the estimation of the baseline shift is necessary, and the removal of baseline drift from the pulse shapes can improve the discrimination performance of FGA. (authors)

  8. Baseline and projected future carbon storage and greenhouse-gas fluxes in the Great Plains region of the United States

    Science.gov (United States)

    Bouchard, Michelle; Butman, David; Hawbaker, Todd; Li, Zhengpeng; Liu, Jinxun; Liu, Shu-Guang; McDonald, Cory; Reker, Ryan R.; Sayler, Kristi; Sleeter, Benjamin; Sohl, Terry; Stackpoole, Sarah; Wein, Anne; Zhu, Zhi-Liang; Zhu, Zhi-Liang

    2011-01-01

    This assessment was conducted to fulfill the requirements of section 712 of the Energy Independence and Security Act (EISA) of 2007 and to improve understanding of carbon and greenhouse gas (GHG) fluxes in the Great Plains region in the central part of the United States. The assessment examined carbon storage, carbon fluxes, and other GHG fluxes (methane and nitrous oxide) in all major terrestrial ecosystems (forests, grasslands/shrublands, agricultural lands, and wetlands) and freshwater aquatic systems (rivers, streams, lakes, and impoundments) in two time periods: baseline (generally in the first half of the 2010s) and future (projections from baseline to 2050). The assessment was based on measured and observed data collected by the U.S. Geological Survey (USGS) and many other agencies and organizations and used remote sensing, statistical methods, and simulation models.

  9. Baseline characteristics in PRIORITY study: Proteomics and mineralocorticoid receptor antagonism for prevention of diabetic nephropathy in type 2 diabetes

    DEFF Research Database (Denmark)

    Tofte, Nete

    diabetic nephRopathy In TYpe 2 diabetic patients with normoalbuminuria) trial, the aim is to confirm that CKD273 can predict microalbuminuria prospectively, and to test whether mineralocorticoid receptor antagonism (MRA) delays progression to microalbuminuria. Here we report the association between CKD273...... and traditional risk factors for diabetic nephropathy at baseline. Materials and methods PRIORITY is an investigator-initiated, prospective, randomized, double blind, placebo-controlled multicentre clinical trial and observational study in normoalbuminuric type 2 diabetic patients. Patients are stratified...... is development of microalbuminuria. Results In total 2277 type 2 diabetic patients have been screened over a time period of 2.5 years and 1811 are included from 15 sites. Table 1 shows the baseline characteristics. 224 (12.4%) have the high-risk CKD273 pattern. The high- and low-risk populations differ...

  10. Meter-wavelength observations of pulsars using very long baseline interferometry

    International Nuclear Information System (INIS)

    Vandenberg, N.R.

    1974-07-01

    The results of an investigation of the angular structure imposed on pulsar radiation due to scattering in the interstellar medium are presented. The technique of very-long-baseline interferometry was used to obtain the necessary high angular resolution. The interferometers formed by the Arecibo, NRAO, and Sugar Grove telescopes were used at radio frequencies of 196, 111, and 74 MHz during seven separate observing sessions between November 1971 and February 1973. A crude visibility function for the Crab nebular pulsar was obtained along with the correlated pulse profile. The technique of differential fringe phase was used to show that the pulsar and the compact source in the Crab nebula are coincident to within 0.001 arcsec which corresponds to approximately 2 a.u. at the distance to the nebula. The ratio of pulsing to total flux, and the fringe visibility of the time-averaged pulsing flux are also discussed, and apparent angular sizes of the pulsars were measured. (U.S.)

  11. Control advances for achieving the ITER baseline scenario on KSTAR

    Science.gov (United States)

    Eidietis, N. W.; Barr, J.; Hahn, S. H.; Humphreys, D. A.; in, Y. K.; Jeon, Y. M.; Lanctot, M. J.; Mueller, D.; Walker, M. L.

    2017-10-01

    Control methodologies developed to enable successful production of ITER baseline scenario (IBS) plasmas on the superconducting KSTAR tokamak are presented: decoupled vertical control (DVC), real-time feedforward (rtFF) calculation, and multi-input multi-output (MIMO) X-point control. DVC provides fast vertical control with the in-vessel control coils (IVCC) while sharing slow vertical control with the poloidal field (PF) coils to avoid IVCC saturation. rtFF compensates for inaccuracies in offline PF current feedforward programming, allowing reduction or removal of integral gain (and its detrimental phase lag) from the shape controller. Finally, MIMO X-point control provides accurate positioning of the X-point despite low controllability due to the large distance between coils and plasma. Combined, these techniques enabled achievement of IBS parameters (q95 = 3.2, βN = 2) with a scaled ITER shape on KSTAR. n =2 RMP response displays a strong dependence upon this shaping. Work supported by the US DOE under Award DE-SC0010685 and the KSTAR project.

  12. 75 FR 63452 - ONEOK Gas Storage, L.L.C.; Notice of Baseline Filing

    Science.gov (United States)

    2010-10-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-67-001] ONEOK Gas Storage, L.L.C.; Notice of Baseline Filing October 7, 2010. Take notice that on October 1, 2010, ONEOK Gas Storage, L.L.C. submitted a revised baseline filing of its Statement of Operating Conditions for services...

  13. Sport and team differences on baseline measures of sport-related concussion.

    Science.gov (United States)

    Zimmer, Adam; Piecora, Kyle; Schuster, Danielle; Webbe, Frank

    2013-01-01

    With the advent of the National Collegiate Athletic Association's (NCAA's) mandating the presence and practice of concussion-management plans in collegiate athletic programs, institutions will consider potential approaches for concussion management, including both baseline and normative comparison approaches. To examine sport and team differences in baseline performance on a computer-based neurocognitive measure and 2 standard sideline measures of cognition and balance and to determine the potential effect of premorbid factors sex and height on baseline performance. Cross-sectional study. University laboratory. A total of 437 NCAA Division II student-athletes (males = 273, females = 164; age = 19.61 ± 1.64 years, height = 69.89 ± 4.04 inches [177.52 ± 10.26 cm]) were recruited during mandatory preseason testing conducted in a concussion-management program. The computerized Concussion Resolution Index (CRI), the Standardized Assessment of Concussion (Form A; SAC), and the Balance Error Scoring System (BESS). Players on the men's basketball team tended to perform worse on the baseline measures, whereas soccer players tended to perform better. We found a difference in total BESS scores between these sports (P = .002). We saw a difference between sports on the hard-surface portion of the BESS (F6,347 = 3.33, P = .003, ηp(2) = 0.05). No sport, team, or sex differences were found with SAC scores (P > .05). We noted differences between sports and teams in the CRI indices, with basketball, particularly the men's team, performing worse than soccer (P sport differences, height was a covariate for the team (F1,385 = 5.109, P = .02, ηp(2) = 0.013) and sport (F1,326 = 11.212, P = .001, ηp(2) = 0.033) analyses, but the interaction of sex and sport on CRI indices was not significant in any test (P > .05). Given that differences in neurocognitive functioning and performance among sports and teams exist, the comparison of posttraumatic and baseline assessment may lead to more

  14. SRP Baseline Hydrogeologic Investigation, Phase 3

    Energy Technology Data Exchange (ETDEWEB)

    Bledsoe, H.W.

    1988-08-01

    The SRP Baseline Hydrogeologic Investigation was implemented for the purpose of updating and improving the knowledge and understanding of the hydrogeologic systems underlying the SRP site. Phase III, which is discussed in this report, includes the drilling of 7 deep coreholes (sites P-24 through P-30) and the installation of 53 observation wells ranging in depth from approximately 50 ft to more than 970 ft below the ground surface. In addition to the collection of geologic cores for lithologic and stratigraphic study, samples were also collected for the determination of physical characteristics of the sediments and for the identification of microorganisms.

  15. Baseline-dependent averaging in radio interferometry

    Science.gov (United States)

    Wijnholds, S. J.; Willis, A. G.; Salvini, S.

    2018-05-01

    This paper presents a detailed analysis of the applicability and benefits of baseline-dependent averaging (BDA) in modern radio interferometers and in particular the Square Kilometre Array. We demonstrate that BDA does not affect the information content of the data other than a well-defined decorrelation loss for which closed form expressions are readily available. We verify these theoretical findings using simulations. We therefore conclude that BDA can be used reliably in modern radio interferometry allowing a reduction of visibility data volume (and hence processing costs for handling visibility data) by more than 80 per cent.

  16. Rationing in the presence of baselines

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter

    2013-01-01

    We analyze a general model of rationing in which agents have baselines, in addition to claims against the (insufficient) endowment of the good to be allocated. Many real-life problems fit this general model (e.g., bankruptcy with prioritized claims, resource allocation in the public health care...... sector, water distribution in drought periods). We introduce (and characterize) a natural class of allocation methods for this model. Any method within the class is associated with a rule in the standard rationing model, and we show that if the latter obeys some focal properties, the former obeys them...

  17. Technical baseline description for in situ vitrification laboratory test equipment

    International Nuclear Information System (INIS)

    Beard, K.V.; Bonnenberg, R.W.; Watson, L.R.

    1991-09-01

    IN situ vitrification (ISV) has been identified as possible waste treatment technology. ISV was developed by Pacific Northwest Laboratory (PNL), Richland, Washington, as a thermal treatment process to treat contaminated soils in place. The process, which electrically melts and dissolves soils and associated inorganic materials, simultaneously destroys and/or removes organic contaminants while incorporating inorganic contaminants into a stable, glass-like residual product. This Technical Baseline Description has been prepared to provide high level descriptions of the design of the Laboratory Test model, including all design modifications and safety improvements made to data. Furthermore, the Technical Baseline Description provides a basic overview of the interface documents for configuration management, program management interfaces, safety, quality, and security requirements. 8 figs

  18. Association of baseline bleeding pattern on amenorrhea with levonorgestrel intrauterine system use.

    Science.gov (United States)

    Mejia, Manuela; McNicholas, Colleen; Madden, Tessa; Peipert, Jeffrey F

    2016-11-01

    This study aims to evaluate the effect of baseline bleeding patterns on rates of amenorrhea reported at 12 months in levonorgestrel (LNG) 52 mg intrauterine system (IUS) users. We also assessed the effect of baseline bleeding patterns at 3 and 6 months postinsertion. In this secondary analysis of the Contraceptive CHOICE Project, we included participants who had an LNG-IUS inserted within 1 month of enrollment and continued use for 12 months. Using 12-month telephone survey data, we defined amenorrhea at 12 months of use as no bleeding or spotting during the previous 6 months. We used chi-square and multivariable logistic regression to assess the association of baseline bleeding pattern with amenorrhea while controlling for confounding variables. Of 1802 continuous 12-month LNG-IUS users, amenorrhea was reported by 4.9%, 14.8% and 15.4% of participants at 3, 6 and 12 months, receptively. Participants with light baseline bleeding or short duration of flow reported higher rates of amenorrhea at 3 and 6 months postinsertion (pamenorrhea at 3 and 6 months (pamenorrhea at 12 months than those who reported moderate bleeding (OR adj , 0.36; 95% CI, 0.16-0.69). Women with heavier menstrual bleeding are less likely than women with moderate flow to report amenorrhea following 12 months of LNG-IUS use. Baseline heavy menstrual flow reduces the likelihood of amenorrhea with LNG-IUS use, information that could impact contraceptive counseling. Anticipatory counseling can improve method satisfaction and continuation, an important strategy to continue to reduce unintended pregnancy and abortion rates. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Baseline Radioactivity Measurements In The Vicinity Of A Gold ...

    African Journals Online (AJOL)

    Western Region, Ghana) to obtain baseline radioactivity data prior to the installation of Cs-137 nuclear density gauges for quality control measure-ment of the density of slurry in the pipelines at the plant. A survey meter, gamma spectrometry and ...

  20. Meta-Analysis of the Relation of Baseline Right Ventricular Function to Response to Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Sharma, Abhishek; Bax, Jerome J; Vallakati, Ajay; Goel, Sunny; Lavie, Carl J; Kassotis, John; Mukherjee, Debabrata; Einstein, Andrew; Warrier, Nikhil; Lazar, Jason M

    2016-04-15

    Right ventricular (RV) dysfunction has been associated with adverse clinical outcomes in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) improves left ventricular (LV) size and function in patients with markedly abnormal electrocardiogram QRS duration. However, relation of baseline RV function with response to CRT has not been well described. In this study, we aim to investigate the relation of baseline RV function with response to CRT as assessed by change in LV ejection fraction (EF). A systematic search of studies published from 1966 to May 31, 2015 was conducted using PubMed, CINAHL, Cochrane CENTRAL, and the Web of Science databases. Studies were included if they have reported (1) parameters of baseline RV function (tricuspid annular plane systolic excursion [TAPSE] or RVEF or RV basal strain or RV fractional area change [FAC]) and (2) LVEF before and after CRT. Random-effects metaregression was used to evaluate the effect of baseline RV function parameters and change in LVEF. Sixteen studies (n = 1,764) were selected for final analysis. Random-effects metaregression analysis showed no significant association between the magnitude of the difference in EF before and after CRT with baseline TAPSE (β = 0.005, p = 0.989); baseline RVEF (β = 0.270, p = 0.493); baseline RVFAC (β = -0.367, p = 0.06); baseline basal strain (β = -0.342, p = 0.462) after a mean follow-up period of 10.5 months. In conclusion, baseline RV function as assessed by TAPSE, FAC, basal strain, or RVEF does not determine response to CRT as assessed by change in LVEF. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Baseline and Target Values for PV Forecasts: Toward Improved Solar Power Forecasting: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Hodge, Bri-Mathias; Lu, Siyuan; Hamann, Hendrik F.; Lehman, Brad; Simmons, Joseph; Campos, Edwin; Banunarayanan, Venkat

    2015-08-05

    Accurate solar power forecasting allows utilities to get the most out of the solar resources on their systems. To truly measure the improvements that any new solar forecasting methods can provide, it is important to first develop (or determine) baseline and target solar forecasting at different spatial and temporal scales. This paper aims to develop baseline and target values for solar forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output. forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output.

  2. Low baseline levels of NK cells may predict a positive response to ipilimumab in melanoma therapy.

    Science.gov (United States)

    Tietze, Julia K; Angelova, Daniela; Heppt, Markus V; Ruzicka, Thomas; Berking, Carola

    2017-07-01

    The introduction of immune checkpoint blockade (ICB) has been a breakthrough in the therapy of metastatic melanoma. The influence of ICB on T-cell populations has been studied extensively, but little is known about the effect on NK cells. In this study, we analysed the relative and absolute amounts of NK cells and of the subpopulations of CD56 dim and CD56 bright NK cells among the peripheral blood mononuclear cells (PBMCs) of 32 patients with metastatic melanoma before and under treatment with ipilimumab or pembrolizumab by flow cytometry. In 15 (47%) patients, an abnormal low amount of NK cells was found at baseline. Analysis of the subpopulations showed also low or normal baseline levels for CD56 dim NK cells, whereas the baseline levels of CD56 bright NK cells were either normal or abnormally high. The relative and absolute amounts of NK cells and of CD56 dim and CD56 bright NK cell subpopulations in patients with a normal baseline did not change under treatment. However, patients with a low baseline of NK cells and CD56 dim NK cells showed a significant increase in these immune cell subsets, but the amounts remained to be lower than the normal baseline. The amount of CD56 bright NK cells was unaffected by treatment. The baseline levels of NK cells were correlated with the number of metastatic organs. Their proportion increased, whereas the expression of NKG2D decreased significantly when more than one organ was affected by metastases. Low baseline levels of NK cells and CD56 dim NK cells as well as normal baseline levels of CD56 bright NK cells correlated significantly with a positive response to ipilimumab but not to pembrolizumab. Survival curves of patients with low amounts of CD56 dim NK cells treated with ipilimumab showed a trend to longer survival. Normal baseline levels of CD56 bright NK cells were significantly correlated with longer survival as compared to patients with high baseline levels. In conclusion, analysis of the amounts of total NK cells

  3. Imputation of Baseline LDL Cholesterol Concentration in Patients with Familial Hypercholesterolemia on Statins or Ezetimibe.

    Science.gov (United States)

    Ruel, Isabelle; Aljenedil, Sumayah; Sadri, Iman; de Varennes, Émilie; Hegele, Robert A; Couture, Patrick; Bergeron, Jean; Wanneh, Eric; Baass, Alexis; Dufour, Robert; Gaudet, Daniel; Brisson, Diane; Brunham, Liam R; Francis, Gordon A; Cermakova, Lubomira; Brophy, James M; Ryomoto, Arnold; Mancini, G B John; Genest, Jacques

    2018-02-01

    Familial hypercholesterolemia (FH) is the most frequent genetic disorder seen clinically and is characterized by increased LDL cholesterol (LDL-C) (>95th percentile), family history of increased LDL-C, premature atherosclerotic cardiovascular disease (ASCVD) in the patient or in first-degree relatives, presence of tendinous xanthomas or premature corneal arcus, or presence of a pathogenic mutation in the LDLR , PCSK9 , or APOB genes. A diagnosis of FH has important clinical implications with respect to lifelong risk of ASCVD and requirement for intensive pharmacological therapy. The concentration of baseline LDL-C (untreated) is essential for the diagnosis of FH but is often not available because the individual is already on statin therapy. To validate a new algorithm to impute baseline LDL-C, we examined 1297 patients. The baseline LDL-C was compared with the imputed baseline obtained within 18 months of the initiation of therapy. We compared the percent reduction in LDL-C on treatment from baseline with the published percent reductions. After eliminating individuals with missing data, nonstandard doses of statins, or medications other than statins or ezetimibe, we provide data on 951 patients. The mean ± SE baseline LDL-C was 243.0 (2.2) mg/dL [6.28 (0.06) mmol/L], and the mean ± SE imputed baseline LDL-C was 244.2 (2.6) mg/dL [6.31 (0.07) mmol/L] ( P = 0.48). There was no difference in response according to the patient's sex or in percent reduction between observed and expected for individual doses or types of statin or ezetimibe. We provide a validated estimation of baseline LDL-C for patients with FH that may help clinicians in making a diagnosis. © 2017 American Association for Clinical Chemistry.

  4. An Energy Efficiency Evaluation Method Based on Energy Baseline for Chemical Industry

    OpenAIRE

    Yao, Dong-mei; Zhang, Xin; Wang, Ke-feng; Zou, Tao; Wang, Dong; Qian, Xin-hua

    2016-01-01

    According to the requirements and structure of ISO 50001 energy management system, this study proposes an energy efficiency evaluation method based on energy baseline for chemical industry. Using this method, the energy plan implementation effect in the processes of chemical production can be evaluated quantitatively, and evidences for system fault diagnosis can be provided. This method establishes the energy baseline models which can meet the demand of the different kinds of production proce...

  5. Baseline radiological monitoring at proposed uranium prospecting site at Rohil Sikar, Rajasthan

    International Nuclear Information System (INIS)

    Kumar, Rajesh; Jha, V.N.; Sahoo, N.K.; Jha, S.K.; Tripathi, R.M.

    2018-01-01

    Once economically viable grades of uranium deposits are proposed for mining and processing by the industry radiological baseline studies are required for future comparison during operational phases. The information collected during such studies serve as connecting feature between regulatory compliance and technical information. Present paper summarizes the results of baseline monitoring of atmospheric 222 Rn and gamma level in the area at prospecting mining, milling and waste disposal sites of Rohil Rajasthan

  6. Quantifying the extent of North American mammal extinction relative to the pre-anthropogenic baseline.

    Science.gov (United States)

    Carrasco, Marc A; Barnosky, Anthony D; Graham, Russell W

    2009-12-16

    Earth has experienced five major extinction events in the past 450 million years. Many scientists suggest we are now witnessing a sixth, driven by human impacts. However, it has been difficult to quantify the real extent of the current extinction episode, either for a given taxonomic group at the continental scale or for the worldwide biota, largely because comparisons of pre-anthropogenic and anthropogenic biodiversity baselines have been unavailable. Here, we compute those baselines for mammals of temperate North America, using a sampling-standardized rich fossil record to reconstruct species-area relationships for a series of time slices ranging from 30 million to 500 years ago. We show that shortly after humans first arrived in North America, mammalian diversity dropped to become at least 15%-42% too low compared to the "normal" diversity baseline that had existed for millions of years. While the Holocene reduction in North American mammal diversity has long been recognized qualitatively, our results provide a quantitative measure that clarifies how significant the diversity reduction actually was. If mass extinctions are defined as loss of at least 75% of species on a global scale, our data suggest that North American mammals had already progressed one-fifth to more than halfway (depending on biogeographic province) towards that benchmark, even before industrialized society began to affect them. Data currently are not available to make similar quantitative estimates for other continents, but qualitative declines in Holocene mammal diversity are also widely recognized in South America, Eurasia, and Australia. Extending our methodology to mammals in these areas, as well as to other taxa where possible, would provide a reasonable way to assess the magnitude of global extinction, the biodiversity impact of extinctions of currently threatened species, and the efficacy of conservation efforts into the future.

  7. Quantifying the extent of North American mammal extinction relative to the pre-anthropogenic baseline.

    Directory of Open Access Journals (Sweden)

    Marc A Carrasco

    2009-12-01

    Full Text Available Earth has experienced five major extinction events in the past 450 million years. Many scientists suggest we are now witnessing a sixth, driven by human impacts. However, it has been difficult to quantify the real extent of the current extinction episode, either for a given taxonomic group at the continental scale or for the worldwide biota, largely because comparisons of pre-anthropogenic and anthropogenic biodiversity baselines have been unavailable. Here, we compute those baselines for mammals of temperate North America, using a sampling-standardized rich fossil record to reconstruct species-area relationships for a series of time slices ranging from 30 million to 500 years ago. We show that shortly after humans first arrived in North America, mammalian diversity dropped to become at least 15%-42% too low compared to the "normal" diversity baseline that had existed for millions of years. While the Holocene reduction in North American mammal diversity has long been recognized qualitatively, our results provide a quantitative measure that clarifies how significant the diversity reduction actually was. If mass extinctions are defined as loss of at least 75% of species on a global scale, our data suggest that North American mammals had already progressed one-fifth to more than halfway (depending on biogeographic province towards that benchmark, even before industrialized society began to affect them. Data currently are not available to make similar quantitative estimates for other continents, but qualitative declines in Holocene mammal diversity are also widely recognized in South America, Eurasia, and Australia. Extending our methodology to mammals in these areas, as well as to other taxa where possible, would provide a reasonable way to assess the magnitude of global extinction, the biodiversity impact of extinctions of currently threatened species, and the efficacy of conservation efforts into the future.

  8. The dry eye assessment and management (DREAM©) study: Study design and baseline characteristics.

    Science.gov (United States)

    Asbell, Penny A; Maguire, Maureen G; Peskin, Ellen; Bunya, Vatinee Y; Kuklinski, Eric J

    2018-06-05

    Describe trial design and baseline characteristics of participants in the DRy Eye Assessment and Management (DREAM©) Study. Prospective, multi-center, randomized, double-masked "real-world" clinical trial assessing efficacy and safety of oral omega-3 (ω3) supplementation for the treatment of dry eye disease (DED). RESULTS: Mean age of participants was 58.0 ± 13.2 years. Mean OSDI score at baseline was 44.4 ± 14.2. Mean conjunctival staining score (scale 0-6) was 3.0 ± 1.4, corneal staining score (scale 0-15) was 3.9 ± 2.7, tear break-up time was 3.1 ± 1.5 s, and Schirmer test was 9.6 ± 6.5 mm/5 min. DREAM© participants mirror real world patients who seek intervention for their DED-related symptoms despite their current treatments. Results regarding the efficacy of omega-3 supplementation will be helpful to clinicians and patients with moderate to severe DED who are considering omega-3 as a treatment. This trial design may be a model for future RCT's on nutritional supplements and DED treatments seeking to provide useful information for clinical practice. ClinicalTrials.gov number NCT02128763. Copyright © 2017. Published by Elsevier Inc.

  9. Super-NOvA a long-baseline neutrino experiment with two off-axis detectors

    CERN Document Server

    Requejo, O M; Pascoli, S; Requejo, Olga Mena; Palomares-Ruiz, Sergio; Pascoli, Silvia

    2005-01-01

    Establishing the neutrino mass hierarchy is one of the fundamental questions that will have to be addressed in the next future. Its determination could be obtained with long-baseline experiments but typically suffers from degeneracies with other neutrino parameters. We consider here the NOvA experiment configuration and propose to place a second off-axis detector, with a shorter baseline, such that, by exploiting matter effects, the type of neutrino mass hierarchy could be determined with only the neutrino run. We show that the determination of this parameter is free of degeneracies, provided the ratio L/E, where L the baseline and E is the neutrino energy, is the same for both detectors.

  10. Depression CBT treatment gains among HIV-infected persons with a history of injection drug use varies as a function of baseline substance use.

    Science.gov (United States)

    Labbe, Allison K; O'Cleirigh, Conall M; Stein, Michael; Safren, Steven A

    2015-01-01

    Depression and substance use, the most common comorbidities with HIV, are both associated with poor treatment outcomes and accelerated HIV disease progression. Though previous research has demonstrated short-term and follow-up success for cognitive behavioral therapy for adherence and depression (CBT-AD) on depression outcomes among patients with HIV in care and among patients with HIV in active substance abuse treatment for injection drug use (IDU), there is little information regarding possible moderating effects of active use versus abstinence on depression treatment gains. The present study aimed to examine recent substance use at treatment initiation as a moderator of the acute and maintenance effects of CBT-AD on depression. We used data from a two-arm, randomized controlled trial (N = 89) comparing CBT-AD to enhanced treatment as usual in individuals in treatment for IDU. To test whether depression at time of presentation affected outcomes, repeated-measures ANOVAs were conducted for two time frames: (1) acute phase (baseline to post-treatment) (acute) and (2) maintenance phase (baseline to 12-month follow-up). To further examine maintenance of gains, we additionally looked at post-treatment to 12-month follow-up. Depression scores derived from the clinical global impression for severity and the Montgomery-Asberg depression rating scale (MADRS) served as the primary outcome variables. Acute (baseline post treatment) moderation effects were found for those patients endorsing active drug use at baseline in the CBT-AD condition, who demonstrated the greatest reductions in MADRS scores at post-treatment (F[1,76] = 6.78, p = .01) and follow-up (F[1,61] = 5.46, p = .023). Baseline substance use did not moderate differences from post-treatment to 12-month follow-up as depression treatment gains that occurred acutely from baseline to post-treatment were maintained across both patients engaged in substance use and abstainers. We conclude that CBT

  11. The impact of sterile neutrinos on CP measurements at long baselines

    International Nuclear Information System (INIS)

    Gandhi, Raj; Kayser, Boris; Masud, Mehedi; Prakash, Suprabh

    2015-01-01

    With the Deep Underground Neutrino Experiment (DUNE) as an example, we show that the presence of even one sterile neutrino of mass ∼1 eV can significantly impact the measurements of CP violation in long baseline experiments. Using a probability level analysis and neutrino-antineutrino asymmetry calculations, we discuss the large magnitude of these effects, and show how they translate into significant event rate deviations at DUNE. Our results demonstrate that measurements which, when interpreted in the context of the standard three family paradigm, indicate CP conservation at long baselines, may, in fact hide large CP violation if there is a sterile state. Similarly, any data indicating the violation of CP cannot be properly interpreted within the standard paradigm unless the presence of sterile states of mass O(1 eV) can be conclusively ruled out. Our work underscores the need for a parallel and linked short baseline oscillation program and a highly capable near detector for DUNE, in order that its highly anticipated results on CP violation in the lepton sector may be correctly interpreted.

  12. Predicting pornography use over time: Does self-reported "addiction" matter?

    Science.gov (United States)

    Grubbs, Joshua B; Wilt, Joshua A; Exline, Julie J; Pargament, Kenneth I

    2018-07-01

    In recent years, several works have reported on perceived addiction to internet pornography, or the potential for some individuals to label their own use of pornography as compulsive or out of control. Such works have consistently found that perceived addiction is related to concerning outcomes such as psychological distress, relational distress, and other addictive behaviors. However, very little work has specifically examined whether or not perceived addiction is actually related to increased use of pornography, cross-sectionally or over time. The present work sought to address this deficit in the literature. Using two longitudinal samples (Sample 1, Baseline N = 3988; Sample 2, Baseline N = 1047), a variety of factors (e.g., male gender, lower religiousness, and lower self-control) were found to predict any use of pornography. Among those that acknowledged use (Sample 1, Baseline N = 1352; Sample 2, Baseline N = 793), perceived addiction to pornography consistently predicted greater average daily use of pornography. At subsequent longitudinal follow-ups (Sample 1, Baseline N = 265; Sample 2, One Month Later, N = 410, One Year Later, N = 360), only male gender and baseline average pornography use consistently predicted future use. These findings suggest that perceived addiction to pornography is associated with concurrent use of pornography, but does not appear to predict use over time, suggesting that perceived addiction may not always be an accurate indicator of behavior or addiction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. 12-Mo Intervention of Physical Exercise Improved Work Ability, Especially in Subjects with Low Baseline Work Ability

    Directory of Open Access Journals (Sweden)

    Oili Kettunen

    2014-04-01

    Full Text Available Objectives: This study’s objective was to assess the effects of a 12-month physical exercise intervention on work ability (WAI and cardiorespiratory fitness (CRF in healthy working adults. Methods: The study group had 371 participants, of which 338 (212 women and 126 men were allocated in the exercise group and 33 (17 women and 16 men in the control group. The exercise group underwent a 12-month exercise program followed by a 12-month follow-up. WAI and CRF were evaluated at baseline, and at 4, 8, 12, and 24 study months, in both exercise and control groups. The exercise group was divided into subgroups according to baseline WAI classifications (poor/moderate, good, excellent. Results: During the 12-month exercise intervention, the exercise group increased their leisure-time physical activity by 71% (p = 0.016 and improved the mean WAI by 3% and CRF by 7% (p < 0.0001, in both, while WAI and CRF decreased in the control group (ANCOVA using age, sex and BMI as covariates, for WAI, p = 0.013 and for CRF, p = 0.008. The changes in WAI and CRF between the exercise group and control group were significantly different during the intervention (baseline vs. 12-months, p = 0.028 and p = 0.007 and after the follow-up (p = 0.001 and p = 0.040, respectively. A light positive correlation between the changes in WAI and in CRF (r = 0.19, p < 0.01 existed. WAI improvement was the highest (13%, p < 0.0001 in the subgroup having poor/moderate WAI at baseline (ANCOVA, p < 0.001. Conclusions: The improvement of WAI associated with CRF. These results suggest that a physical exercise intervention may improve work ability.

  14. Pinellas Plant Environmental Baseline Report

    Energy Technology Data Exchange (ETDEWEB)

    1997-06-01

    The Pinellas Plant has been part of the Department of Energy`s (DOE) nuclear weapons complex since the plant opened in 1957. In March 1995, the DOE sold the Pinellas Plant to the Pinellas County Industry Council (PCIC). DOE has leased back a large portion of the plant site to facilitate transition to alternate use and safe shutdown. The current mission is to achieve a safe transition of the facility from defense production and prepare the site for alternative uses as a community resource for economic development. Toward that effort, the Pinellas Plant Environmental Baseline Report (EBR) discusses the current and past environmental conditions of the plant site. Information for the EBR is obtained from plant records. Historical process and chemical usage information for each area is reviewed during area characterizations.

  15. Local Stressors, Resilience, and Shifting Baselines on Coral Reefs.

    Science.gov (United States)

    McLean, Matthew; Cuetos-Bueno, Javier; Nedlic, Osamu; Luckymiss, Marston; Houk, Peter

    2016-01-01

    Understanding how and why coral reefs have changed over the last twenty to thirty years is crucial for sustaining coral-reef resilience. We used a historical baseline from Kosrae, a typical small island in Micronesia, to examine changes in fish and coral assemblages since 1986. We found that natural gradients in the spatial distribution of fish and coral assemblages have become amplified, as island geography is now a stronger determinant of species abundance patterns, and habitat forming Acropora corals and large-bodied fishes that were once common on the leeward side of the island have become scarce. A proxy for fishing access best predicted the relative change in fish assemblage condition over time, and in turn, declining fish condition was the only factor correlated with declining coral condition, suggesting overfishing may have reduced ecosystem resilience. Additionally, a proxy for watershed pollution predicted modern coral assemblage condition, suggesting pollution is also reducing resilience in densely populated areas. Altogether, it appears that unsustainable fishing reduced ecosystem resilience, as fish composition has shifted to smaller species in lower trophic levels, driven by losses of large predators and herbivores. While prior literature and anecdotal reports indicate that major disturbance events have been rare in Kosrae, small localized disturbances coupled with reduced resilience may have slowly degraded reef condition through time. Improving coral-reef resilience in the face of climate change will therefore require improved understanding and management of growing artisanal fishing pressure and watershed pollution.

  16. Local Stressors, Resilience, and Shifting Baselines on Coral Reefs.

    Directory of Open Access Journals (Sweden)

    Matthew McLean

    Full Text Available Understanding how and why coral reefs have changed over the last twenty to thirty years is crucial for sustaining coral-reef resilience. We used a historical baseline from Kosrae, a typical small island in Micronesia, to examine changes in fish and coral assemblages since 1986. We found that natural gradients in the spatial distribution of fish and coral assemblages have become amplified, as island geography is now a stronger determinant of species abundance patterns, and habitat forming Acropora corals and large-bodied fishes that were once common on the leeward side of the island have become scarce. A proxy for fishing access best predicted the relative change in fish assemblage condition over time, and in turn, declining fish condition was the only factor correlated with declining coral condition, suggesting overfishing may have reduced ecosystem resilience. Additionally, a proxy for watershed pollution predicted modern coral assemblage condition, suggesting pollution is also reducing resilience in densely populated areas. Altogether, it appears that unsustainable fishing reduced ecosystem resilience, as fish composition has shifted to smaller species in lower trophic levels, driven by losses of large predators and herbivores. While prior literature and anecdotal reports indicate that major disturbance events have been rare in Kosrae, small localized disturbances coupled with reduced resilience may have slowly degraded reef condition through time. Improving coral-reef resilience in the face of climate change will therefore require improved understanding and management of growing artisanal fishing pressure and watershed pollution.

  17. Camera Trajectory fromWide Baseline Images

    Science.gov (United States)

    Havlena, M.; Torii, A.; Pajdla, T.

    2008-09-01

    angle θ of its corresponding rays w.r.t. the optical axis as θ = ar 1+br2 . After a successful calibration, we know the correspondence of the image points to the 3D optical rays in the coordinate system of the camera. The following steps aim at finding the transformation between the camera and the world coordinate systems, i.e. the pose of the camera in the 3D world, using 2D image matches. For computing 3D structure, we construct a set of tentative matches detecting different affine covariant feature regions including MSER, Harris Affine, and Hessian Affine in acquired images. These features are alternative to popular SIFT features and work comparably in our situation. Parameters of the detectors are chosen to limit the number of regions to 1-2 thousands per image. The detected regions are assigned local affine frames (LAF) and transformed into standard positions w.r.t. their LAFs. Discrete Cosine Descriptors are computed for each region in the standard position. Finally, mutual distances of all regions in one image and all regions in the other image are computed as the Euclidean distances of their descriptors and tentative matches are constructed by selecting the mutually closest pairs. Opposed to the methods using short baseline images, simpler image features which are not affine covariant cannot be used because the view point can change a lot between consecutive frames. Furthermore, feature matching has to be performed on the whole frame because no assumptions on the proximity of the consecutive projections can be made for wide baseline images. This is making the feature detection, description, and matching much more time-consuming than it is for short baseline images and limits the usage to low frame rate sequences when operating in real-time. Robust 3D structure can be computed by RANSAC which searches for the largest subset of the set of tentative matches which is, within a predefined threshold ", consistent with an epipolar geometry. We use ordered sampling as

  18. Overview of the Long-Baseline Neutrino Facility cryogenic system

    CERN Document Server

    Montanari, David; Bremer, Johan; Delaney, Michael; Aurelien, Diaz; Doubnik, Roza; Haaf, Kevin; Hentschel, Steve; Norris, Barry; Voirin, Erik

    2017-01-01

    The Deep Underground Neutrino Experiment (DUNE) collaboration is developing a multi-kiloton Long-Baseline neutrino experiment that will be located one mile underground at the Sanford Underground Research Facility (SURF) in Lead, SD. In the present design, detectors will be located inside four cryostats filled with a total of 68,400 ton of ultrapure liquid argon, at the level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The Long-Baseline Neutrino Facility (LBNF) is developing the conventional facilities and cryogenics infrastructure supporting this experiment. The cryogenics system is composed of several sub-systems: External/Infrastructure, Proximity, and Internal cryogenics. It will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution highlights the main features of the LBNF cryogenic system. It presents its performance, functional requirements and modes of operations. It also details the status of the design, ...

  19. Decomposition for emission baseline setting in China's electricity sector

    International Nuclear Information System (INIS)

    Steenhof, Paul A.

    2007-01-01

    Decomposition analysis is used to generate carbon dioxide emission baselines in China's electricity sector to the year 2020. This is undertaken from the vantage point of the final consumer of electricity, and therefore considers factors influencing electricity demand, efficiency of generation, sources of energy used for generation purposes, and the effectiveness of transmission and distribution. It is found that since 1980, gains in efficiency of generation have been the most important factor affecting change in the emission intensity of electricity generated. Based upon known energy and economic policy, efficiency gains will continue to contribute to reductions in the emission intensity of electricity generated, however, fuel shifts to natural gas and increases in nuclear generation will further these trends into the future. The analysis confirms other sources in the literature that decomposition is an appropriate technique available for baseline construction, thereby suitable for the emerging carbon market and its related mechanisms

  20. The Female Athlete Body (FAB) study: Rationale, design, and baseline characteristics.

    Science.gov (United States)

    Stewart, Tiffany M; Pollard, Tarryn; Hildebrandt, Tom; Beyl, Robbie; Wesley, Nicole; Kilpela, Lisa Smith; Becker, Carolyn Black

    2017-09-01

    Eating Disorders (EDs) are serious psychiatric illnesses marked by psychiatric comorbidity, medical complications, and functional impairment. Research indicates that female athletes are often at greater risk for developing ED pathology versus non-athlete females. The Female Athlete Body (FAB) study is a three-site, randomized controlled trial (RCT) designed to assess the efficacy of a behavioral ED prevention program for female collegiate athletes when implemented by community providers. This paper describes the design, intervention, and participant baseline characteristics. Future papers will discuss outcomes. Female collegiate athletes (N=481) aged 17-21 were randomized by site, team, and sport type to either FAB or a waitlist control group. FAB consisted of three sessions (1.3h each) of a behavioral ED prevention program. Assessments were conducted at baseline (pre-intervention), post-intervention (3weeks), and six-, 12-, and 18-month follow-ups. This study achieved 96% (N=481) of target recruitment (N=500). Few group differences emerged at baseline. Total sample analyses revealed moderately low baseline instances of ED symptoms and clinical cases. Health risks associated with EDs necessitate interventions for female athletes. The FAB study is the largest existing RCT for female athletes aimed at both reduction of ED risk factors and ED prevention. The methods presented and population recruited for this study represent an ideal intervention for assessing the effects of FAB on both the aforementioned outcomes. We anticipate that findings of this study (reported in future papers) will make a significant contribution to the ED risk factor reduction and prevention literature. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Baseline Characteristics of fall from Height Victims Presenting to Emergency Department; a Brief Report.

    Science.gov (United States)

    Hatamabadi, Hamidreza; Arhami Dolatabadi, Ali; Atighinasab, Batoul; Safari, Saeed

    2017-01-01

    Trauma due to accidents or fall from height is a major cause of disability and mortality. The present study was designed aiming to evaluate the baseline characteristics of fall from height victims presenting to emergency department (ED). This prospective cross-sectional study evaluates the baseline characteristics of fall from height cases presenting to EDs of three educational Hospitals, Tehran, Iran, during one year. Data were analyzed using SPSS 21 and presented using descriptive statistics. 460 patients with the mean age of 27.89 ± 20.95 years were evaluated (76.5% male). 191 (41.5%) falls occurred when working, 27 (5.9%) during play, and 242 (52.6%) in other times. Among construction workers, 166 (81.4%) had not used any safety equipment. Fracture and dislocation with 180 (39.1%) cases and soft tissue injury with 166 (36.1%) were the most common injuries inflicted. Mean height of falling was 3.41 ± 0.34 (range: 0.5 - 20) meters. Finally, 8 (1.7%) of the patients died (50% intentional) and 63% were discharged from ED. A significant correlation was detected between mortality and the falls being intentional (p construction workers, with less than high school diploma education level. Intentional fall and greater height of falling significantly correlated with mortality.

  2. Item analysis of ADAS-Cog: effect of baseline cognitive impairment in a clinical AD trial.

    Science.gov (United States)

    Sevigny, Jeffrey J; Peng, Yahong; Liu, Lian; Lines, Christopher R

    2010-03-01

    We explored the association of Alzheimer's disease (AD) Assessment Scale (ADAS-Cog) item scores with AD severity using cross-sectional and longitudinal data from the same study. Post hoc analyses were performed using placebo data from a 12-month trial of patients with mild-to-moderate AD (N =281 randomized, N =209 completed). Baseline distributions of ADAS-Cog item scores by Mini-Mental State Examination (MMSE) score and Clinical Dementia Rating (CDR) sum of boxes score (measures of dementia severity) were estimated using local and nonparametric regressions. Mixed-effect models were used to characterize ADAS-Cog item score changes over time by dementia severity (MMSE: mild =21-26, moderate =14-20; global CDR: mild =0.5-1, moderate =2). In the cross-sectional analysis of baseline ADAS-Cog item scores, orientation was the most sensitive item to differentiate patients across levels of cognitive impairment. Several items showed a ceiling effect, particularly in milder AD. In the longitudinal analysis of change scores over 12 months, orientation was the only item with noticeable decline (8%-10%) in mild AD. Most items showed modest declines (5%-20%) in moderate AD.

  3. Impact of baseline BMI and weight change in CCTG adjuvant breast cancer trials.

    Science.gov (United States)

    Yerushalmi, R; Dong, B; Chapman, J W; Goss, P E; Pollak, M N; Burnell, M J; Levine, M N; Bramwell, V H C; Pritchard, K I; Whelan, T J; Ingle, J N; Shepherd, L E; Parulekar, W R; Han, L; Ding, K; Gelmon, K A

    2017-07-01

    We hypothesized that increased baseline BMI and BMI change would negatively impact clinical outcomes with adjuvant breast cancer systemic therapy. Data from chemotherapy trials MA.5 and MA.21; endocrine therapy MA.12, MA.14 and MA.27; and trastuzumab HERA/MA.24 were analyzed. The primary objective was to examine the effect of BMI change on breast cancer-free interval (BCFI) landmarked at 5 years; secondary objectives included BMI changes at 1 and 3 years; BMI changes on disease-specific survival (DSS) and overall survival (OS); and effects of baseline BMI. Stratified analyses included trial therapy and composite trial stratification factors. In pre-/peri-/early post-menopausal chemotherapy trials (N = 2793), baseline BMI did not impact any endpoint and increased BMI from baseline did not significantly affect BCFI (P = 0.85) after 5 years although it was associated with worse BCFI (P = 0.03) and DSS (P = 0.07) after 1 year. BMI increase by 3 and 5 years was associated with better DSS (P = 0.01; 0.01) and OS (P = 0.003; 0.05). In pre-menopausal endocrine therapy trial MA.12 (N = 672), patients with higher baseline BMI had worse BCFI (P = 0.02) after 1 year, worse DSS (P = 0.05; 0.004) after 1 and 5 years and worse OS (P = 0.01) after 5 years. Increased BMI did not impact BCFI (P = 0.90) after 5 years, although it was associated with worse BCFI (P = 0.01) after 1 year. In post-menopausal endocrine therapy trials MA.14 and MA.27 (N = 8236), baseline BMI did not significantly impact outcome for any endpoint. BMI change did not impact BCFI or DSS after 1 or 3 years, although a mean increased BMI of 0.3 was associated with better OS (P = 0.02) after 1 year. With the administration of trastuzumab (N = 1395) baseline BMI and BMI change did not significantly impact outcomes. Higher baseline BMI and BMI increases negatively affected outcomes only in pre-/peri-/early post-menopausal trial patients. Otherwise, BMI

  4. Biofuels Baseline 2008

    Energy Technology Data Exchange (ETDEWEB)

    Hamelinck, C.; Koper, M.; Berndes, G.; Englund, O.; Diaz-Chavez, R.; Kunen, E.; Walden, D.

    2011-10-15

    The European Union is promoting the use of biofuels and other renewable energy in transport. In April 2009, the Renewable Energy Directive (2009/28/EC) was adopted that set a 10% target for renewable energy in transport in 2020. The directive sets several requirements to the sustainability of biofuels marketed in the frame of the Directive. The Commission is required to report to the European Parliament on a regular basis on a range of sustainability impacts resulting from the use of biofuels in the EU. This report serves as a baseline of information for regular monitoring on the impacts of the Directive. Chapter 2 discusses the EU biofuels market, the production and consumption of biofuels and international trade. It is derived where the feedstock for EU consumed biofuels originally come from. Chapter 3 discusses the biofuel policy framework in the EU and major third countries of supply. It looks at various policy aspects that are relevant to comply with the EU sustainability requirements. Chapter 4 discusses the environmental and social sustainability aspects associated with EU biofuels and their feedstock. Chapter 5 discusses the macro-economic effects that indirectly result from increased EU biofuels consumption, on commodity prices and land use. Chapter 6 presents country factsheets for main third countries that supplied biofuels to the EU market in 2008.

  5. A Multi-Baseline 12 GHz Atmospheric Phase Interferometer with One Micron Path Length Sensitivity

    Science.gov (United States)

    Kimberk, Robert S.; Hunter, Todd R.; Leiker, Patrick S.; Blundell, Raymond; Nystrom, George U.; Petitpas, Glen R.; Test, John; Wilson, Robert W.; Yamaguchi, Paul; Young, Kenneth H.

    2012-12-01

    We have constructed a five station 12 GHz atmospheric phase interferometer (API) for the Submillimeter Array (SMA) located near the summit of Mauna Kea, Hawaii. Operating at the base of unoccupied SMA antenna pads, each station employs a commercial low noise mixing block coupled to a 0.7 m off-axis satellite dish which receives a broadband, white noise-like signal from a geostationary satellite. The signals are processed by an analog correlator to produce the phase delays between all pairs of stations with projected baselines ranging from 33-261 m. Each baseline's amplitude and phase is measured continuously at a rate of 8 kHz, processed, averaged and output at 10 Hz. Further signal processing and data reduction is accomplished with a Linux computer, including the removal of the diurnal motion of the target satellite. The placement of the stations below ground level with an environmental shield combined with the use of low temperature coefficient, buried fiber optic cables provides excellent system stability. The sensitivity in terms of rms path length is 1.3 microns which corresponds to phase deviations of about 1° of phase at the highest operating frequency of the SMA. The two primary data products are: (1) standard deviations of observed phase over various time scales, and (2) phase structure functions. These real-time statistical data measured by the API in the direction of the satellite provide an estimate of the phase front distortion experienced by the concurrent SMA astronomical observations. The API data also play an important role, along with the local opacity measurements and weather predictions, in helping to plan the scheduling of science observations on the telescope.

  6. Workload and time management in central cancer registries: baseline data and implication for registry staffing.

    Science.gov (United States)

    Chapman, Susan A; Mulvihill, Linda; Herrera, Carolina

    2012-01-01

    The Workload and Time Management Survey of Central Cancer Registries was conducted in 2011 to assess the amount of time spent on work activities usually performed by cancer registrars. A survey including 39 multi-item questions,together with a work activities data collection log, was sent by email to the central cancer registry (CCR) manager in each of the 50 states and the District of Columbia. Twenty-four central cancer registries (47%) responded to the survey.Results indicate that registries faced reductions in budgeted staffing from 2008-2009. The number of source records and total cases were important indicators of workload. Four core activities, including abstracting at the registry, visual editing,case consolidation, and resolving edit reports, accounted for about half of registry workload. We estimate an average of 12.4 full-time equivalents (FTEs) are required to perform all cancer registration activities tracked by the survey; however,estimates vary widely by registry size. These findings may be useful for registries as a benchmark for their own registry workload and time-management data and to develop staffing guidelines.

  7. CORONARY DIET INTERVENTION WITH OLIVE OIL AND CARDIOVASCULAR PREVENTION STUDY (THE CORDIOPREV STUDY): RATIONALE, METHODS, AND BASELINE CHARACTERISTICS

    Science.gov (United States)

    Delgado-Lista, Javier; Perez-Martinez, Pablo; Garcia-Rios, Antonio; Alcala-Diaz, Juan F; Perez-Caballero, Ana I.; Gomez-Delgado, Francisco; Fuentes, Francisco; Quintana-Navarro, Gracia; Lopez-Segura, Fernando; Ortiz-Morales, Ana M; Delgado-Casado, Nieves; Yubero-Serrano, Elena; Camargo, Antonio; Marin, Carmen; Rodriguez-Cantalejo, Fernando; Gomez-Luna, Purificacion; Ordovas, Jose M; Lopez-Miranda, Jose; Perez-Jimenez, Francisco

    2016-01-01

    Coronary heart disease (CHD) represents a major global health burden. However, despite the well-known influence that dietary habits exert over the progression of this disease, there are no well-established and scientifically sound dietary approaches to prevent the onset of clinical outcomes in secondary prevention. The objective of the CORonary Diet Intervention with Olive oil and cardiovascular PREVention study (CORDIOPREV study, clinical trials number NCT00924937) is to compare the ability of a Mediterranean diet rich in virgin olive oil versus a low-fat diet to influence the composite incidence of cardiovascular events after 7 years, in subjects with documented CHD at baseline. For this purpose, we enrolled 1002 coronary patients from Spain. Baseline assessment (2009–12) included detailed interviews and measurements to assess dietary, social and biological variables. Results of baseline characteristics: The CORDIOPREV study in Spain describes a population with a high BMI (37.2% overweight and 56.3% obesity), with a median of LDL-cholesterol of 88.5 mg/dL (70.6% of the patients having <100 mg/dL, and 20.3% patients < 70 mg/dL). 9.6% of the participants were active smokers, and 64.4% were former smokers. Metabolic Syndrome was present in 58% of this population. To sum up, we describe here the rationale, methods and baseline characteristics of the CORDIOPREV study, which will test for the first time the efficacy of a Mediterranean Diet rich in extra virgin olive oil as compared with a low-fat diet on the incidence of CHD recurrence in a long term follow-up study. PMID:27297848

  8. Analysis of baseline gene expression levels from ...

    Science.gov (United States)

    The use of gene expression profiling to predict chemical mode of action would be enhanced by better characterization of variance due to individual, environmental, and technical factors. Meta-analysis of microarray data from untreated or vehicle-treated animals within the control arm of toxicogenomics studies has yielded useful information on baseline fluctuations in gene expression. A dataset of control animal microarray expression data was assembled by a working group of the Health and Environmental Sciences Institute's Technical Committee on the Application of Genomics in Mechanism Based Risk Assessment in order to provide a public resource for assessments of variability in baseline gene expression. Data from over 500 Affymetrix microarrays from control rat liver and kidney were collected from 16 different institutions. Thirty-five biological and technical factors were obtained for each animal, describing a wide range of study characteristics, and a subset were evaluated in detail for their contribution to total variability using multivariate statistical and graphical techniques. The study factors that emerged as key sources of variability included gender, organ section, strain, and fasting state. These and other study factors were identified as key descriptors that should be included in the minimal information about a toxicogenomics study needed for interpretation of results by an independent source. Genes that are the most and least variable, gender-selectiv

  9. High Rates of Baseline Drug Resistance and Virologic Failure Among ART-naive HIV-infected Children in Mali.

    Science.gov (United States)

    Crowell, Claudia S; Maiga, Almoustapha I; Sylla, Mariam; Taiwo, Babafemi; Kone, Niaboula; Oron, Assaf P; Murphy, Robert L; Marcelin, Anne-Geneviève; Traore, Ban; Fofana, Djeneba B; Peytavin, Gilles; Chadwick, Ellen G

    2017-11-01

    Limited data exist on drug resistance and antiretroviral treatment (ART) outcomes in HIV-1-infected children in West Africa. We determined the prevalence of baseline resistance and correlates of virologic failure (VF) in a cohort of ART-naive HIV-1-infected children baseline (before ART) and at 6 months. Resistance was defined according to the Stanford HIV Genotypic Resistance database. VF was defined as viral load ≥1000 copies/mL after 6 months of ART. Logistic regression was used to evaluate factors associated with VF or death >1 month after enrollment. Post hoc, antiretroviral concentrations were assayed on baseline samples of participants with baseline resistance. One-hundred twenty children with a median age 2.6 years (interquartile range: 1.6-5.0) were included. Eighty-eight percent reported no prevention of mother-to-child transmission exposure. At baseline, 27 (23%), 4 (3%) and none had non-nucleoside reverse transcriptase inhibitor (NNRTI), nucleoside reverse transcriptase inhibitor or protease inhibitor resistance, respectively. Thirty-nine (33%) developed VF and 4 died >1 month post-ART initiation. In multivariable analyses, poor adherence [odds ratio (OR): 6.1, P = 0.001], baseline NNRTI resistance among children receiving NNRTI-based ART (OR: 22.9, P baseline NNRTI resistance (OR: 5.8, P = 0.018) were significantly associated with VF/death. Ten (38%) with baseline resistance had detectable levels of nevirapine or efavirenz at baseline; 7 were currently breastfeeding, but only 2 reported maternal antiretroviral use. Baseline NNRTI resistance was common in children without reported NNRTI exposure and was associated with increased risk of treatment failure. Detectable NNRTI concentrations were present despite few reports of maternal/infant antiretroviral use.

  10. Project management with dynamic scheduling baseline scheduling, risk analysis and project control

    CERN Document Server

    Vanhoucke, Mario

    2013-01-01

    The topic of this book is known as dynamic scheduling, and is used to refer to three dimensions of project management and scheduling: the construction of a baseline schedule and the analysis of a project schedule's risk as preparation of the project control phase during project progress. This dynamic scheduling point of view implicitly assumes that the usability of a project's baseline schedule is rather limited and only acts as a point of reference in the project life cycle.

  11. An Energy Efficiency Evaluation Method Based on Energy Baseline for Chemical Industry

    Directory of Open Access Journals (Sweden)

    Dong-mei Yao

    2016-01-01

    Full Text Available According to the requirements and structure of ISO 50001 energy management system, this study proposes an energy efficiency evaluation method based on energy baseline for chemical industry. Using this method, the energy plan implementation effect in the processes of chemical production can be evaluated quantitatively, and evidences for system fault diagnosis can be provided. This method establishes the energy baseline models which can meet the demand of the different kinds of production processes and gives the general solving method of each kind of model according to the production data. Then the energy plan implementation effect can be evaluated and also whether the system is running normally can be determined through the baseline model. Finally, this method is used on cracked gas compressor unit of ethylene plant in some petrochemical enterprise; it can be proven that this method is correct and practical.

  12. Baseline Plasma C-Reactive Protein Concentrations and Motor Prognosis in Parkinson Disease.

    Directory of Open Access Journals (Sweden)

    Atsushi Umemura

    Full Text Available C-reactive protein (CRP, a blood inflammatory biomarker, is associated with the development of Alzheimer disease. In animal models of Parkinson disease (PD, systemic inflammatory stimuli can promote neuroinflammation and accelerate dopaminergic neurodegeneration. However, the association between long-term systemic inflammations and neurodegeneration has not been assessed in PD patients.To investigate the longitudinal effects of baseline CRP concentrations on motor prognosis in PD.Retrospective analysis of 375 patients (mean age, 69.3 years; mean PD duration, 6.6 years. Plasma concentrations of high-sensitivity CRP were measured in the absence of infections, and the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III scores were measured at five follow-up intervals (Days 1-90, 91-270, 271-450, 451-630, and 631-900.Change of UPDRS-III scores from baseline to each of the five follow-up periods.Change in UPDRS-III scores was significantly greater in PD patients with CRP concentrations ≥0.7 mg/L than in those with CRP concentrations <0.7 mg/L, as determined by a generalized estimation equation model (P = 0.021 for the entire follow-up period and by a generalized regression model (P = 0.030 for the last follow-up interval (Days 631-900. The regression coefficients of baseline CRP for the two periods were 1.41 (95% confidence interval [CI] 0.21-2.61 and 2.62 (95% CI 0.25-4.98, respectively, after adjusting for sex, age, baseline UPDRS-III score, dementia, and incremental L-dopa equivalent dose.Baseline plasma CRP levels were associated with motor deterioration and predicted motor prognosis in patients with PD. These associations were independent of sex, age, PD severity, dementia, and anti-Parkinsonian agents, suggesting that subclinical systemic inflammations could accelerate neurodegeneration in PD.

  13. Mercury exposure may suppress baseline corticosterone levels in juvenile birds.

    Science.gov (United States)

    Herring, Garth; Ackerman, Joshua T; Herzog, Mark P

    2012-06-05

    Mercury exposure has been associated with a wide variety of negative reproductive responses in birds, however few studies have examined the potential for chick impairment via the hypothalamic-pituitary-adrenal (HPA) axis. The HPA axis regulates corticosterone levels during periods of stress. We examined the relationship between baseline fecal corticosterone metabolite concentrations and mercury concentrations in down feathers of recently hatched (feathers (decreasing by 45% across the range of observed mercury concentrations) while accounting for stronger positive correlations between corticosterone concentrations and colony nest abundance and date. These results indicate that chronic mercury exposure may suppress baseline corticosterone concentrations in tern chicks and suggests that a juvenile bird's ability to respond to stress may be reduced via the downregulation of the HPA axis.

  14. BASELINE DESIGN/ECONOMICS FOR ADVANCED FISCHER-TROPSCH TECHNOLOGY; FINAL

    International Nuclear Information System (INIS)

    None

    1998-01-01

    Bechtel, along with Amoco as the main subcontractor, developed a Baseline design, two alternative designs, and computer process simulation models for indirect coal liquefaction based on advanced Fischer-Tropsch (F-T) technology for the U. S. Department of Energy's (DOE's) Federal Energy Technology Center (FETC)

  15. The Dutch CAFE baseline: In or out of line?

    NARCIS (Netherlands)

    Jimmink BA; Folkert RJM; Thomas R; Beck JP; Eerdt MM van; Elzenga HE; Hoek KW van der; Hoen A; Peek CJ; LED; KMD; NMD; LVM; RIM; LDL

    2004-01-01

    The European Commission is constructing a strategy on air pollution within the Clean Air For Europe (CAFE) programme. This strategy will be based on assessments using the RAINS model for different policy ambitions where the CAFE baseline scenario and control strategies are employed. The Netherlands

  16. Emergency Response Capability Baseline Needs Assessment - Requirements Document

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2016-10-04

    This document was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by LLNL Emergency Management Department Head James Colson. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only addresses emergency response.

  17. Reconsidering Cluster Bias in Multilevel Data: A Monte Carlo Comparison of Free and Constrained Baseline Approaches.

    Science.gov (United States)

    Guenole, Nigel

    2018-01-01

    The test for item level cluster bias examines the improvement in model fit that results from freeing an item's between level residual variance from a baseline model with equal within and between level factor loadings and between level residual variances fixed at zero. A potential problem is that this approach may include a misspecified unrestricted model if any non-invariance is present, but the log-likelihood difference test requires that the unrestricted model is correctly specified. A free baseline approach where the unrestricted model includes only the restrictions needed for model identification should lead to better decision accuracy, but no studies have examined this yet. We ran a Monte Carlo study to investigate this issue. When the referent item is unbiased, compared to the free baseline approach, the constrained baseline approach led to similar true positive (power) rates but much higher false positive (Type I error) rates. The free baseline approach should be preferred when the referent indicator is unbiased. When the referent assumption is violated, the false positive rate was unacceptably high for both free and constrained baseline approaches, and the true positive rate was poor regardless of whether the free or constrained baseline approach was used. Neither the free or constrained baseline approach can be recommended when the referent indicator is biased. We recommend paying close attention to ensuring the referent indicator is unbiased in tests of cluster bias. All Mplus input and output files, R, and short Python scripts used to execute this simulation study are uploaded to an open access repository.

  18. Baseline assessment of fish communities of the Flower Garden Banks

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The work developed baseline information on fish and benthic communities within the Flower Garden Banks National Marine Sanctuary (FGBNMS). Surveys employed diving,...

  19. OCRWM baseline management procedure for document identifiers

    International Nuclear Information System (INIS)

    1993-03-01

    This procedure establishes a uniform numbering system (document identifier) for all Program and project technical, cost, and schedule baselines, and selected management and procurement documents developed for and controlled by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System (CRWMS). The document identifier defined in this procedure is structured to ensure that the relational integrity between configuration items (CIs) and their associated documentation and software is maintained, traceable, categorical, and retrievable for the life of the program

  20. 77 FR 31866 - Intent To Request Approval From OMB of One New Public Collection of Information: Baseline...

    Science.gov (United States)

    2012-05-30

    ... From OMB of One New Public Collection of Information: Baseline Assessment for Security Enhancement... across public transportation systems. TSA developed the Baseline Assessment for Security Enhancement... be used as follows: 1. To develop a baseline understanding of a public transportation agency's...

  1. Mixed Waste Focus Area integrated technical baseline report, Phase 1: Volume 1

    International Nuclear Information System (INIS)

    1996-01-01

    The Department of Energy (DOE) established the Mixed Waste Characterization, Treatment, and Disposal Focus Area (MWFA) to develop and facilitate implementation of technologies required to meet the Department's commitments for treatment of mixed low-level and transuranic wastes. The mission of the MWFA is to provide acceptable treatment systems, developed in partnership with users and with participation of stakeholders, tribal governments, and regulators, that are capable of treating DOE's mixed waste. These treatment systems include all necessary steps such as characterization, pretreatment, and disposal. To accomplish this mission, a technical baseline is being established that forms the basis for determining which technology development activities will be supported by the MWFA. The technical baseline is the prioritized list of deficiencies, and the resulting technology development activities needed to overcome these deficiencies. This document presents Phase I of the technical baseline development process, which resulted in the prioritized list of deficiencies that the MWFA will address. A summary of the data and the assumptions upon which this work was based is included, as well as information concerning the DOE Office of Environmental Management (EM) mixed waste technology development needs. The next phase in the technical baseline development process, Phase II, will result in the identification of technology development activities that will be conducted through the MWFA to resolve the identified deficiencies

  2. SRP baseline hydrogeologic investigation: Aquifer characterization

    Energy Technology Data Exchange (ETDEWEB)

    Strom, R.N.; Kaback, D.S.

    1992-03-31

    An investigation of the mineralogy and chemistry of the principal hydrogeologic units and the geochemistry of the water in the principal aquifers at Savannah River Site (SRS) was undertaken as part of the Baseline Hydrogeologic Investigation. This investigation was conducted to provide background data for future site studies and reports and to provide a site-wide interpretation of the geology and geochemistry of the Coastal Plain Hydrostratigraphic province. Ground water samples were analyzed for major cations and anions, minor and trace elements, gross alpha and beta, tritium, stable isotopes of hydrogen, oxygen, and carbon, and carbon-14. Sediments from the well borings were analyzed for mineralogy and major and minor elements.

  3. Web Server for Peak Detection, Baseline Correction, and Alignment in Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics Data.

    Science.gov (United States)

    Tian, Tze-Feng; Wang, San-Yuan; Kuo, Tien-Chueh; Tan, Cheng-En; Chen, Guan-Yuan; Kuo, Ching-Hua; Chen, Chi-Hsin Sally; Chan, Chang-Chuan; Lin, Olivia A; Tseng, Y Jane

    2016-11-01

    Two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) is superior for chromatographic separation and provides great sensitivity for complex biological fluid analysis in metabolomics. However, GC×GC/TOF-MS data processing is currently limited to vendor software and typically requires several preprocessing steps. In this work, we implement a web-based platform, which we call GC 2 MS, to facilitate the application of recent advances in GC×GC/TOF-MS, especially for metabolomics studies. The core processing workflow of GC 2 MS consists of blob/peak detection, baseline correction, and blob alignment. GC 2 MS treats GC×GC/TOF-MS data as pictures and clusters the pixels as blobs according to the brightness of each pixel to generate a blob table. GC 2 MS then aligns the blobs of two GC×GC/TOF-MS data sets according to their distance and similarity. The blob distance and similarity are the Euclidean distance of the first and second retention times of two blobs and the Pearson's correlation coefficient of the two mass spectra, respectively. GC 2 MS also directly corrects the raw data baseline. The analytical performance of GC 2 MS was evaluated using GC×GC/TOF-MS data sets of Angelica sinensis compounds acquired under different experimental conditions and of human plasma samples. The results show that GC 2 MS is an easy-to-use tool for detecting peaks and correcting baselines, and GC 2 MS is able to align GC×GC/TOF-MS data sets acquired under different experimental conditions. GC 2 MS is freely accessible at http://gc2ms.web.cmdm.tw .

  4. Application of a net-based baseline correction scheme to strong-motion records of the 2011 Mw 9.0 Tohoku earthquake

    Science.gov (United States)

    Tu, Rui; Wang, Rongjiang; Zhang, Yong; Walter, Thomas R.

    2014-06-01

    The description of static displacements associated with earthquakes is traditionally achieved using GPS, EDM or InSAR data. In addition, displacement histories can be derived from strong-motion records, allowing an improvement of geodetic networks at a high sampling rate and a better physical understanding of earthquake processes. Strong-motion records require a correction procedure appropriate for baseline shifts that may be caused by rotational motion, tilting and other instrumental effects. Common methods use an empirical bilinear correction on the velocity seismograms integrated from the strong-motion records. In this study, we overcome the weaknesses of an empirically based bilinear baseline correction scheme by using a net-based criterion to select the timing parameters. This idea is based on the physical principle that low-frequency seismic waveforms at neighbouring stations are coherent if the interstation distance is much smaller than the distance to the seismic source. For a dense strong-motion network, it is plausible to select the timing parameters so that the correlation coefficient between the velocity seismograms of two neighbouring stations is maximized after the baseline correction. We applied this new concept to the KiK-Net and K-Net strong-motion data available for the 2011 Mw 9.0 Tohoku earthquake. We compared the derived coseismic static displacement with high-quality GPS data, and with the results obtained using empirical methods. The results show that the proposed net-based approach is feasible and more robust than the individual empirical approaches. The outliers caused by unknown problems in the measurement system can be easily detected and quantified.

  5. The London low emission zone baseline study.

    Science.gov (United States)

    Kelly, Frank; Armstrong, Ben; Atkinson, Richard; Anderson, H Ross; Barratt, Ben; Beevers, Sean; Cook, Derek; Green, Dave; Derwent, Dick; Mudway, Ian; Wilkinson, Paul

    2011-11-01

    On February 4, 2008, the world's largest low emission zone (LEZ) was established. At 2644 km2, the zone encompasses most of Greater London. It restricts the entry of the oldest and most polluting diesel vehicles, including heavy-goods vehicles (haulage trucks), buses and coaches, larger vans, and minibuses. It does not apply to cars or motorcycles. The LEZ scheme will introduce increasingly stringent Euro emissions standards over time. The creation of this zone presented a unique opportunity to estimate the effects of a stepwise reduction in vehicle emissions on air quality and health. Before undertaking such an investigation, robust baseline data were gathered on air quality and the oxidative activity and metal content of particulate matter (PM) from air pollution monitors located in Greater London. In addition, methods were developed for using databases of electronic primary-care records in order to evaluate the zone's health effects. Our study began in 2007, using information about the planned restrictions in an agreed-upon LEZ scenario and year-on-year changes in the vehicle fleet in models to predict air pollution concentrations in London for the years 2005, 2008, and 2010. Based on this detailed emissions and air pollution modeling, the areas in London were then identified that were expected to show the greatest changes in air pollution concentrations and population exposures after the implementation of the LEZ. Using these predictions, the best placement of a pollution monitoring network was determined and the feasibility of evaluating the health effects using electronic primary-care records was assessed. To measure baseline pollutant concentrations before the implementation of the LEZ, a comprehensive monitoring network was established close to major roadways and intersections. Output-difference plots from statistical modeling for 2010 indicated seven key areas likely to experience the greatest change in concentrations of nitrogen dioxide (NO2) (at least 3

  6. 75 FR 51990 - CenterPoint Energy-Illinois Gas Transmission Company; Notice of Baseline Filing

    Science.gov (United States)

    2010-08-24

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-80-000] CenterPoint Energy--Illinois Gas Transmission Company; Notice of Baseline Filing August 17, 2010. Take notice that on August 12, 2010, the applicant listed above submitted their baseline filing of its Statement of Operating...

  7. Abstract: Notes from the Field: Establishing Baseline Data for ...

    African Journals Online (AJOL)

    Abstract: Notes from the Field: Establishing Baseline Data for Pressure Ulcers in a Rwandan Intensive Care Unit. Gedeon Mutabazi, Jessie Silver. Abstract. Abstract. Background Pressure ulcers are a common iatrogenic medical problem. Pressure ulcers increase the morbidity and mortality of hospitalized patients as well as ...

  8. ecotaxonomic baseline evaluation of the plant species in a ...

    African Journals Online (AJOL)

    Admin

    plant species of medicinal and other economic values. The investigation was ... A total of 41 and 24 representative ... INTRODUCTION. Baseline .... at 100m interval, involving a total of 15 sampling locations .... explained by factors such as climate, productivity and ... encouraging the: Maintenance of traditional tree species.

  9. NOvA Short-Baseline Tau Neutrino Appearance Search

    Energy Technology Data Exchange (ETDEWEB)

    Keloth, Rijeesh [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexander [Cincinnati U.; Davies, Gavin S [Indiana U.; Suter, Louise [Fermilab; Plunkett, Robert K [Fermilab

    2017-10-01

    Standard three-flavor neutrino oscillations have well explained by a wide range of neutrino experiments. However, the anomalous results, such as electron-antineutrino excess seen by LSND and MiniBooNE do not fit the three-flavor paradigm. This can be explained by an additional fourth flavor sterile neutrino at a larger scale than the existing three flavor neutrinos. The NOvA experiment consists of two finely segmented, liquid scintillator detectors operating 14 .6 mrad off-axis from the NuMI muon-neutrino beam. The Near Detector is located on the Fermilab campus, 1 km from the NuMI target, while the Far Detector is located at Ash River, MN, 810 km from the NuMI target. The NOvA experiment is primarily designed to measure electron-neutrino appearance at the Far Detector using the Near Detector to control systematic uncertainties; however, the Near Detector is well suited for searching for anomalous short-baseline oscillations. This poster will present a novel method for selecting tau neutrino interactions with high purity at the Near Detector using a convolutional neural network. Using this method, the sensitivity to anomalous short-baseline tau-neutrino appearance due to sterile neutrino oscillations will be presented.

  10. Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE): Conceptual Design Report. Volume 3: Long-Baseline Neutrino Facility for DUNE

    Energy Technology Data Exchange (ETDEWEB)

    Strait, James [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); McCluskey, Elaine [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Lundin, Tracy [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Willhite, Joshua [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Hamernik, Thomas [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Papadimitriou, Vaia [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Marchionni, Alberto [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Kim, Min Jeong [National Inst. of Nuclear Physics (INFN), Frascati (Italy). National Lab. of Frascati (INFN-LNF); Nessi, Marzio [Univ. of Geneva (Switzerland); Montanari, David [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Heavey, Anne [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2016-01-21

    This volume of the LBNF/DUNE Conceptual Design Report covers the Long-Baseline Neutrino Facility for DUNE and describes the LBNF Project, which includes design and construction of the beamline at Fermilab, the conventional facilities at both Fermilab and SURF, and the cryostat and cryogenics infrastructure required for the DUNE far detector.

  11. New light Higgs boson and short-baseline neutrino anomalies

    Science.gov (United States)

    Asaadi, J.; Church, E.; Guenette, R.; Jones, B. J. P.; Szelc, A. M.

    2018-04-01

    The low-energy excesses observed by the MiniBooNE experiment have, to date, defied a convincing explanation under the standard model even with accommodation for nonzero neutrino mass. In this paper we explore a new oscillation mechanism to explain these anomalies, invoking a light neutrinophilic Higgs boson, conceived to induce a low Dirac neutrino mass in accord with experimental limits. Beam neutrinos forward scattering off of a locally overdense relic neutrino background give rise to a novel matter effect with an energy-specific resonance. An enhanced oscillation around this resonance peak produces flavor transitions which are highly consistent with the MiniBooNE neutrino- and antineutrino-mode data sets. The model provides substantially improved χ2 values beyond either the no-oscillation hypothesis or the more commonly explored 3 +1 sterile neutrino hypothesis. This mechanism would introduce distinctive signatures at each baseline in the upcoming short-baseline neutrino program at Fermilab, presenting opportunities for further exploration.

  12. COMPARISON OF THREE METHODS TO PROJECT FUTURE BASELINE CARBON EMISSIONS IN TEMPERATE RAINFOREST, CURINANCO, CHILE

    Energy Technology Data Exchange (ETDEWEB)

    Patrick Gonzalez; Antonio Lara; Jorge Gayoso; Eduardo Neira; Patricio Romero; Leonardo Sotomayor

    2005-07-14

    evaluate the three methods to project future baseline carbon emissions. Extrapolation from Landsat change detection uses the observed rate of change to estimate change in the near future. Geomod is a software program that models the geographic distribution of change using a defined rate of change. FRCA is an integrated spatial analysis of forest inventory, biodiversity, and remote sensing that produces estimates of forest biodiversity and forest carbon density, spatial data layers of future probabilities of reforestation and deforestation, and a projection of future baseline forest carbon sequestration and emissions for an ecologically-defined area of analysis. For the period 1999-2012, extrapolation from Landsat change detection estimated a loss of 5000 ha and 520,000 t carbon from closed natural forest; Geomod modeled a loss of 2500 ha and 250 000 t; FRCA projected a loss of 4700 {+-} 100 ha and 480,000 t (maximum 760,000 t, minimum 220,000 t). Concerning labor time, extrapolation for Landsat required 90 actual days or 120 days normalized to Bachelor degree level wages; Geomod required 240 actual days or 310 normalized days; FRCA required 110 actual days or 170 normalized days. Users experienced difficulties with an MS-DOS version of Geomod before turning to the Idrisi version. For organizations with limited time and financing, extrapolation from Landsat change provides a cost-effective method. Organizations with more time and financing could use FRCA, the only method where that calculates the deforestation rate as a dependent variable rather than assuming a deforestation rate as an independent variable. This research indicates that best practices for the projection of baseline carbon emissions include integration of forest inventory and remote sensing tasks from the beginning of the analysis, definition of an analysis area using ecological characteristics, use of standard and widely used geographic information systems (GIS) software applications, and the use of species

  13. Relationship between baseline white-matter changes and development of late-life depressive symptoms: 3-year results from the LADIS study

    DEFF Research Database (Denmark)

    Teodorczuk, A; Firbank, M J; Pantoni, L

    2010-01-01

    BACKGROUND: Growing evidence suggests that cerebral white-matter changes and depressive symptoms are linked directly along the causal pathway. We investigated whether baseline severity of cerebral white-matter changes predict longer-term future depressive outcomes in a community sample of non...... volumetrically. Depressive outcomes were assessed in terms of depressive episodes and depressive symptoms, as measured by the Geriatric Depression Scale (GDS). Subjects were clinically reassessed annually for up to 3 years. Regression models were constructed to determine whether baseline severity of white.......09) or incident depression (p=0.08). CONCLUSIONS: Our results support the vascular depression hypothesis and strongly implicate white-matter changes in the pathogenesis of late-life depression. Furthermore, the findings indicate that, over time, part of the relationship between white-matter changes and depression...

  14. Comparison of Three Methods Estimating Baseline Creatinine For Acute Kidney Injury in Hospitalized Patients: a Multicentre Survey in Third-Level Urban Hospitals of China.

    Science.gov (United States)

    Lang, Xia-Bing; Yang, Yi; Yang, Ju-Rong; Wan, Jian-Xin; Yu, Sheng-Qiang; Cui, Jiong; Tang, Xiao-Jing; Chen, Jianghua

    2018-01-01

    A lack of baseline serum creatinine (SCr) data leads to underestimation of the burden caused by acute kidney injury (AKI) in developing countries. The goal of this study was to investigate the effects of various baseline SCr analysis methods on the current diagnosis of AKI in hospitalized patients. Patients with at least one SCr value during their hospital stay between January 1, 2011 and December 31, 2012 were retrospectively included in the study. The baseline SCr was determined either by the minimum SCr (SCrMIN) or the estimated SCr using the MDRD formula (SCrGFR-75). We also used the dynamic baseline SCr (SCrdynamic) in accordance with the 7 day/48 hour time window. AKI was defined based on the KDIGO SCr criteria. Of 562,733 hospitalized patients, 350,458 (62.3%) had at least one SCr determination, and 146,185 (26.0%) had repeat SCr tests. AKI was diagnosed in 13,883 (2.5%) patients using the SCrMIN, 21,281 (3.8%) using the SCrGFR-75 and 9,288 (1.7%) using the SCrdynamic. Compared with the non-AKI patients, AKI patients had a higher in-hospital mortality rate regardless of the baseline SCr analysis method. Because of the scarcity of SCr data, imputation of the baseline SCr is necessary to remedy the missing data. The detection rate of AKI varies depending on the different imputation methods. SCrGFR-75 can identify more AKI cases than the other two methods. © 2018 The Author(s). Published by S. Karger AG, Basel.

  15. Comparison of Three Methods Estimating Baseline Creatinine For Acute Kidney Injury in Hospitalized Patients: a Multicentre Survey in Third-Level Urban Hospitals of China

    Directory of Open Access Journals (Sweden)

    Xia-bing Lang

    2018-02-01

    Full Text Available Background/Aims: A lack of baseline serum creatinine (SCr data leads to underestimation of the burden caused by acute kidney injury (AKI in developing countries. The goal of this study was to investigate the effects of various baseline SCr analysis methods on the current diagnosis of AKI in hospitalized patients. Methods: Patients with at least one SCr value during their hospital stay between January 1, 2011 and December 31, 2012 were retrospectively included in the study. The baseline SCr was determined either by the minimum SCr (SCrMIN or the estimated SCr using the MDRD formula (SCrGFR-75. We also used the dynamic baseline SCr (SCrdynamic in accordance with the 7 day/48 hour time window. AKI was defined based on the KDIGO SCr criteria. Results: Of 562,733 hospitalized patients, 350,458 (62.3% had at least one SCr determination, and 146,185 (26.0% had repeat SCr tests. AKI was diagnosed in 13,883 (2.5% patients using the SCrMIN, 21,281 (3.8% using the SCrGFR-75 and 9,288 (1.7% using the SCrdynamic. Compared with the non-AKI patients, AKI patients had a higher in-hospital mortality rate regardless of the baseline SCr analysis method. Conclusions: Because of the scarcity of SCr data, imputation of the baseline SCr is necessary to remedy the missing data. The detection rate of AKI varies depending on the different imputation methods. SCrGFR-75 can identify more AKI cases than the other two methods.

  16. Sedentary time and markers of inflammation in people with newly diagnosed type 2 diabetes

    Science.gov (United States)

    Falconer, C.L.; Cooper, A.R.; Walhin, J.P.; Thompson, D.; Page, A.S.; Peters, T.J.; Montgomery, A.A.; Sharp, D.J.; Dayan, C.M.; Andrews, R.C.

    2014-01-01

    Background and aims We investigated whether objectively measured sedentary time was associated with markers of inflammation in adults with newly diagnosed type 2 diabetes. Methods and results We studied 285 adults (184 men, 101 women, mean age 59.0 ± 9.7) who had been recruited to the Early ACTivity in Diabetes (Early ACTID) randomised controlled trial. C-reactive protein (CRP), adiponectin, soluble intracellular adhesion molecule-1 (sICAM-1), interleukin-6 (IL-6), and accelerometer-determined sedentary time and moderate-vigorous physical activity (MVPA) were measured at baseline and after six-months. Linear regression analysis was used to investigate the independent cross-sectional and longitudinal associations of sedentary time with markers of inflammation. At baseline, associations between sedentary time and IL-6 were observed in men and women, an association that was attenuated following adjustment for waist circumference. After 6 months of follow-up, sedentary time was reduced by 0.4 ± 1.2 h per day in women, with the change in sedentary time predicting CRP at follow-up. Every hour decrease in sedentary time between baseline and six-months was associated with 24% (1, 48) lower CRP. No changes in sedentary time between baseline and 6 months were seen in men. Conclusions Higher sedentary time is associated with IL-6 in men and women with type 2 diabetes, and reducing sedentary time is associated with improved levels of CRP in women. Interventions to reduce sedentary time may help to reduce inflammation in women with type 2 diabetes. PMID:24925122

  17. Baseline extent of damage predicts spinal radiographic progression in Korean patients with ankylosing spondylitis treated with golimumab.

    Science.gov (United States)

    Lee, Jeong Seok; Song, Yeong Wook; Kim, Tae Hwan; Chung, Won Tae; Lee, Seung Geun; Park, Sung Hwan; Song, Gwan Gyu; Yu, Dae Young; Xu, Stephen; Lee, Eun Young

    2018-05-01

    For patients with ankylosing spondylitis (AS), golimumab has consistent efficacy in controlling disease activity over 5 years but its benefit in preventing radiographic progression was less clear at 4 years. To predict radiographic progression, we analyzed the baseline characteristics of AS patients in a Korean population. Sixty-eight Korean patients with AS participated in the phase 3, multicenter, randomized, placebo-controlled, double-blind trial (GO-RAISE) which has previously been described. Baseline modified stoke AS spine score (mSASSS) and change in mSASSS from baseline (ΔmSASSS) until week 208 were analyzed in the Korean patients enrolled in the GO-RAISE study. Although Korean patients had lower baseline mSASSS compared to non-Korean patients and received active management, radiographic progression was not prevented. Korean patients who did not undergo radiographic progression of spinal lesions of AS were younger and had shorter symptomatic duration, lower Bath AS functional and metrology indices, better chest expansion, and lower baseline mSASSS. The baseline mSASSS and ΔmSASSS were positively correlated in Korean AS patients ( p baseline mSASSS > 10 and less common (13.0%) with baseline mSASSS = 0. In Korean AS patients, radiographic progression of the spine after 4 years was predicted effectively by the initial severity of the spinal lesion(s) in patients treated with golimumab.

  18. Predicting clinical concussion measures at baseline based on motivation and academic profile.

    Science.gov (United States)

    Trinidad, Katrina J; Schmidt, Julianne D; Register-Mihalik, Johna K; Groff, Diane; Goto, Shiho; Guskiewicz, Kevin M

    2013-11-01

    The purpose of this study was to predict baseline neurocognitive and postural control performance using a measure of motivation, high school grade point average (hsGPA), and Scholastic Aptitude Test (SAT) score. Cross-sectional. Clinical research center. Eighty-eight National Collegiate Athletic Association Division I incoming student-athletes (freshman and transfers). Participants completed baseline clinical concussion measures, including a neurocognitive test battery (CNS Vital Signs), a balance assessment [Sensory Organization Test (SOT)], and motivation testing (Rey Dot Counting). Participants granted permission to access hsGPA and SAT total score. Standard scores for each CNS Vital Signs domain and SOT composite score. Baseline motivation, hsGPA, and SAT explained a small percentage of the variance of complex attention (11%), processing speed (12%), and composite SOT score (20%). Motivation, hsGPA, and total SAT score do not explain a significant amount of the variance in neurocognitive and postural control measures but may still be valuable to consider when interpreting neurocognitive and postural control measures.

  19. Scoping paper on new CDM baseline methodology for cross-border power trade

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    Poeyry has been sub-contracted by Carbon Limits, under the African Development Bank CDM Support Programme, to prepare a new CDM baseline methodology for cross border trade, based on a transmission line from Ethiopia to Kenya. The first step in that process is to review the response of the UNFCCC, particularly the Methodologies Panel ('Meth Panel') of the CDM Executive Board, to the various proposals on cross-border trade and interconnection of grids. This report reviews the Methodology Panel and Executive Board decisions on 4 requests for revisions of ACM2 'Consolidated baseline methodology for grid-connected electricity generation from renewable sources', and 5 proposed new baseline methodologies (NM255, NM269, NM272, NM318, NM342), all of which were rejected. We analyse the reasons the methodologies were rejected, and whether the proposed draft Approved Methodology (AM) that the Methodology Panel created in response to NM269 and NM272 is a suitable basis for a new methodology proposal.(auth)

  20. Prediction of short-term changes in symptom severity by baseline plasma homovanillic acid levels in schizophrenic patients receiving clozapine.

    Science.gov (United States)

    Sumiyoshi, T; Hasegawa, M; Jayathilake, K; Meltzer, H Y

    1997-03-24

    The relationship between pretreatment levels of plasma homovanillic acid (pHVA) and the outcome of clozapine treatment was studied in 18 male patients with schizophrenia who were resistant to treatment with conventional neuroleptics. After 6 months of clozapine treatment, 7 patients demonstrated > or = 20% decrease in the Brief Psychiatric Rating Scale (BPRS) (responders), while 11 patients did not (non-responders). Responders and non-responders did not differ with respect to the baseline pHVA level. The BPRS Positive Symptom scores at 6 weeks and 3 months, but not those at baseline and 6 months, following initiation of clozapine treatment negatively correlated with pHVA levels for all patients. The correlations became stronger when only responders were included. No significant correlation between Positive Symptom scores and pHVA levels was observed for non-responders. The BPRS Total and Negative Symptom scores did not correlate with pHVA for all patients, responders or non-responders at any time. The percent decrease in the BPRS Positive Symptom scores from baseline at 6 weeks following clozapine treatment correlated significantly with pHVA levels in responders. These results suggest that pretreatment levels of pHVA can be used to predict relatively short-term changes in the positive symptoms of patients with schizophrenia receiving clozapine treatment, particularly for clozapine responders.