WorldWideScience

Sample records for times prehyperpnea baseline

  1. Parametric estimation of time varying baselines in airborne interferometric SAR

    DEFF Research Database (Denmark)

    Mohr, Johan Jacob; Madsen, Søren Nørvang

    1996-01-01

    A method for estimation of time varying spatial baselines in airborne interferometric synthetic aperture radar (SAR) is described. The range and azimuth distortions between two images acquired with a non-linear baseline are derived. A parametric model of the baseline is then, in a least square...... sense, estimated from image shifts obtained by cross correlation of numerous small patches throughout the image. The method has been applied to airborne EMISAR imagery from the 1995 campaign over the Storstrommen Glacier in North East Greenland conducted by the Danish Center for Remote Sensing. This has...... reduced the baseline uncertainties from several meters to the centimeter level in a 36 km scene. Though developed for airborne SAR the method can easily be adopted to satellite data...

  2. Accounting for baseline differences and measurement error in the analysis of change over time.

    Science.gov (United States)

    Braun, Julia; Held, Leonhard; Ledergerber, Bruno

    2014-01-15

    If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy. Copyright © 2013 John Wiley & Sons, Ltd.

  3. An application of the baseline correction technique for correcting distorted seismic acceleration time histories

    International Nuclear Information System (INIS)

    Lee, Gyu Mahn; Kim, Jong Wook; Jeoung, Kyeong Hoon; Kim, Tae Wan; Park, Keun Bae; Kim, Keung Koo

    2008-03-01

    Three kinds of baseline correction techniques named as 'Newmark', 'Zero-VD' and 'Newmark and Zero-VD' were introduced to correct the distorted physical characteristics of a seismic time history accelogram. The corrected seismic accelerations and distorted raw acceleration showed an identical response spectra in frequency domains, but showed various time history profiles in velocity and displacement domains. The referred correction techniques were programmed with UNIX-HP Fortran. The verification of the baseline corrected seismic data in terms of frequency response spectrum were performed by ANSYS of a commerical FEM software

  4. Baseline simple and complex reaction times in female compared to male boxers.

    Science.gov (United States)

    Bianco, M; Ferri, M; Fabiano, C; Giorgiano, F; Tavella, S; Manili, U; Faina, M; Palmieri, V; Zeppilli, P

    2011-06-01

    The aim of the study was to compare baseline cognitive performance of female in respect to male amateur boxers. Study population included 28 female amateur boxers. Fifty-six male boxers, matched for age, employment and competitive level to female athletes, formed the control group. All boxers had no history of head concussions (except boxing). Each boxer was requested to: 1) fulfill a questionnaire collecting demographic data, level of education, occupational status, boxing record and number of head concussions during boxing; 2) undergo a baseline computerized neuropsychological (NP) test (CogSport) measuring simple and complex reaction times (RT). Female were lighter than male boxers (56±7 vs. 73.1±9.8 kg, Pknock-outs, etc.) correlated with NP scores. Female and male Olympic-style boxers have no (or minimal) differences in baseline cognitive performance. Further research with larger series of female boxers is required to confirm these findings.

  5. Mobile Robots Path Planning Using the Overall Conflict Resolution and Time Baseline Coordination

    Directory of Open Access Journals (Sweden)

    Yong Ma

    2014-01-01

    Full Text Available This paper aims at resolving the path planning problem in a time-varying environment based on the idea of overall conflict resolution and the algorithm of time baseline coordination. The basic task of the introduced path planning algorithms is to fulfill the automatic generation of the shortest paths from the defined start poses to their end poses with consideration of generous constraints for multiple mobile robots. Building on this, by using the overall conflict resolution, within the polynomial based paths, we take into account all the constraints including smoothness, motion boundary, kinematics constraints, obstacle avoidance, and safety constraints among robots together. And time baseline coordination algorithm is proposed to process the above formulated problem. The foremost strong point is that much time can be saved with our approach. Numerical simulations verify the effectiveness of our approach.

  6. Analysis of Seasonal Signal in GPS Short-Baseline Time Series

    Science.gov (United States)

    Wang, Kaihua; Jiang, Weiping; Chen, Hua; An, Xiangdong; Zhou, Xiaohui; Yuan, Peng; Chen, Qusen

    2018-04-01

    Proper modeling of seasonal signals and their quantitative analysis are of interest in geoscience applications, which are based on position time series of permanent GPS stations. Seasonal signals in GPS short-baseline (paper, to better understand the seasonal signal in GPS short-baseline time series, we adopted and processed six different short-baselines with data span that varies from 2 to 14 years and baseline length that varies from 6 to 1100 m. To avoid seasonal signals that are overwhelmed by noise, each of the station pairs is chosen with significant differences in their height (> 5 m) or type of the monument. For comparison, we also processed an approximately zero baseline with a distance of pass-filtered (BP) noise is valid for approximately 40% of the baseline components, and another 20% of the components can be best modeled by a combination of the first-order Gauss-Markov (FOGM) process plus white noise (WN). The TEM displacements are then modeled by considering the monument height of the building structure beneath the GPS antenna. The median contributions of TEM to the annual amplitude in the vertical direction are 84% and 46% with and without additional parts of the monument, respectively. Obvious annual signals with amplitude > 0.4 mm in the horizontal direction are observed in five short-baselines, and the amplitudes exceed 1 mm in four of them. These horizontal seasonal signals are likely related to the propagation of daily/sub-daily TEM displacement or other signals related to the site environment. Mismodeling of the tropospheric delay may also introduce spurious seasonal signals with annual amplitudes of 5 and 2 mm, respectively, for two short-baselines with elevation differences greater than 100 m. The results suggest that the monument height of the additional part of a typical GPS station should be considered when estimating the TEM displacement and that the tropospheric delay should be modeled cautiously, especially with station pairs with

  7. A Baseline-Free Defect Imaging Technique in Plates Using Time Reversal of Lamb Waves

    International Nuclear Information System (INIS)

    Jeong, Hyunjo; Cho, Sungjong; Wei, Wei

    2011-01-01

    We present an analytical investigation for a baseline-free imaging of a defect in plate-like structures using the time-reversal of Lamb waves. We first consider the flexural wave (A 0 mode) propagation in a plate containing a defect, and reception and time reversal process of the output signal at the receiver. The received output signal is then composed of two parts: a directly propagated wave and a scattered wave from the defect. The time reversal of these waves recovers the original input signal, and produces two additional sidebands that contain the time-of-flight information on the defect location. One of the side-band signals is then extracted as a pure defect signal. A defect localization image is then constructed from a beamforming technique based on the time-frequency analysis of the side band signal for each transducer pair in a network of sensors. The simulation results show that the proposed scheme enables the accurate, baseline-free imaging of a defect. (fundamental areas of phenomenology(including applications))

  8. Comparison of pulsar positions from timing and very long baseline astrometry

    Science.gov (United States)

    Wang, J. B.; Coles, W. A.; Hobbs, G.; Shannon, R. M.; Manchester, R. N.; Kerr, M.; Yuan, J. P.; Wang, N.; Bailes, M.; Bhat, N. D. R.; Dai, S.; Dempsey, J.; Keith, M. J.; Lasky, P. D.; Levin, Y.; Osłowski, S.; Ravi, V.; Reardon, D. J.; Rosado, P. A.; Russell, C. J.; Spiewak, R.; van Straten, W.; Toomey, L.; Wen, L.; You, X.-P.; Zhu, X.-J.

    2017-07-01

    Pulsar positions can be measured with high precision using both pulsar timing methods and very long baseline interferometry (VLBI). Pulsar timing positions are referenced to a solar-system ephemeris, whereas VLBI positions are referenced to distant quasars. Here, we compare pulsar positions from published VLBI measurements with those obtained from pulsar timing data from the Nanshan and Parkes radio telescopes in order to relate the two reference frames. We find that the timing positions differ significantly from the VLBI positions (and also differ between different ephemerides). A statistically significant change in the obliquity of the ecliptic of 2.16 ± 0.33 mas is found for the JPL ephemeris DE405, but no significant rotation is found in subsequent JPL ephemerides. The accuracy with which we can relate the two frames is limited by the current uncertainties in the VLBI reference source positions and in matching the pulsars to their reference source. Not only do the timing positions depend on the ephemeris used in computing them, but also different segments of the timing data lead to varying position estimates. These variations are mostly common to all ephemerides, but slight changes are seen at the 10 μas level between ephemerides.

  9. Time-aggregation effects on the baseline of continuous-time and discrete-time hazard models

    NARCIS (Netherlands)

    ter Hofstede, F.; Wedel, M.

    In this study we reinvestigate the effect of time-aggregation for discrete- and continuous-time hazard models. We reanalyze the results of a previous Monte Carlo study by ter Hofstede and Wedel (1998), in which the effects of time-aggregation on the parameter estimates of hazard models were

  10. Reconstruction of baseline time-trace under changing environmental and operational conditions

    International Nuclear Information System (INIS)

    Aryan, P; Kotousov, A; Ng, C T; Wildy, S

    2016-01-01

    Compensation of changing environmental and operational conditions (EOC) is often necessary when using guided-wave based techniques for structural health monitoring in real-world applications. Many studies have demonstrated that the effect of changing EOC can mask damage to a degree that a critical defect might not be detected. Several effective strategies, specifically for compensating the temperature variations, have been developed in recent years. However, many other factors, such as changing humidity and boundary conditions or degradation of material properties, have not received much attention. This paper describes a practical method for reconstruction of the baseline time-trace corresponding to the current EOC. Thus, there is no need for differentiation or compensation procedures when using this method for damage diagnosis. It is based on 3D surface measurements of the velocity field near the actuator using laser vibrometry, in conjunction with high-fidelity finite element simulations of guided wave propagation in free from defects structure. To demonstrate the feasibility and efficiency of the proposed method we provide several examples of the reconstruction and damage detection. (paper)

  11. Reconstruction of baseline time-trace under changing environmental and operational conditions

    Science.gov (United States)

    Aryan, P.; Kotousov, A.; Ng, C. T.; Wildy, S.

    2016-03-01

    Compensation of changing environmental and operational conditions (EOC) is often necessary when using guided-wave based techniques for structural health monitoring in real-world applications. Many studies have demonstrated that the effect of changing EOC can mask damage to a degree that a critical defect might not be detected. Several effective strategies, specifically for compensating the temperature variations, have been developed in recent years. However, many other factors, such as changing humidity and boundary conditions or degradation of material properties, have not received much attention. This paper describes a practical method for reconstruction of the baseline time-trace corresponding to the current EOC. Thus, there is no need for differentiation or compensation procedures when using this method for damage diagnosis. It is based on 3D surface measurements of the velocity field near the actuator using laser vibrometry, in conjunction with high-fidelity finite element simulations of guided wave propagation in free from defects structure. To demonstrate the feasibility and efficiency of the proposed method we provide several examples of the reconstruction and damage detection.

  12. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    Science.gov (United States)

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Workload and time management in central cancer registries: baseline data and implication for registry staffing.

    Science.gov (United States)

    Chapman, Susan A; Mulvihill, Linda; Herrera, Carolina

    2012-01-01

    The Workload and Time Management Survey of Central Cancer Registries was conducted in 2011 to assess the amount of time spent on work activities usually performed by cancer registrars. A survey including 39 multi-item questions,together with a work activities data collection log, was sent by email to the central cancer registry (CCR) manager in each of the 50 states and the District of Columbia. Twenty-four central cancer registries (47%) responded to the survey.Results indicate that registries faced reductions in budgeted staffing from 2008-2009. The number of source records and total cases were important indicators of workload. Four core activities, including abstracting at the registry, visual editing,case consolidation, and resolving edit reports, accounted for about half of registry workload. We estimate an average of 12.4 full-time equivalents (FTEs) are required to perform all cancer registration activities tracked by the survey; however,estimates vary widely by registry size. These findings may be useful for registries as a benchmark for their own registry workload and time-management data and to develop staffing guidelines.

  14. Geometry-specified troposphere decorrelation for subcentimeter real-time kinematic solutions over long baselines

    Science.gov (United States)

    Li, Bofeng; Feng, Yanming; Shen, Yunzhong; Wang, Charles

    2010-11-01

    Real-time kinematic (RTK) GPS techniques have been extensively developed for applications including surveying, structural monitoring, and machine automation. Limitations of the existing RTK techniques that hinder their applications for geodynamics purposes are twofold: (1) the achievable RTK accuracy is on the level of a few centimeters and the uncertainty of vertical component is 1.5-2 times worse than those of horizontal components and (2) the RTK position uncertainty grows in proportional to the base-to-rover distances. The key limiting factor behind the problems is the significant effect of residual tropospheric errors on the positioning solutions, especially on the highly correlated height component. This paper develops the geometry-specified troposphere decorrelation strategy to achieve the subcentimeter kinematic positioning accuracy in all three components. The key is to set up a relative zenith tropospheric delay (RZTD) parameter to absorb the residual tropospheric effects and to solve the established model as an ill-posed problem using the regularization method. In order to compute a reasonable regularization parameter to obtain an optimal regularized solution, the covariance matrix of positional parameters estimated without the RZTD parameter, which is characterized by observation geometry, is used to replace the quadratic matrix of their "true" values. As a result, the regularization parameter is adaptively computed with variation of observation geometry. The experiment results show that new method can efficiently alleviate the model's ill condition and stabilize the solution from a single data epoch. Compared to the results from the conventional least squares method, the new method can improve the long-range RTK solution precision from several centimeters to the subcentimeter in all components. More significantly, the precision of the height component is even higher. Several geosciences applications that require subcentimeter real-time solutions can

  15. Instantaneous Real-Time Kinematic Decimeter-Level Positioning with BeiDou Triple-Frequency Signals over Medium Baselines.

    Science.gov (United States)

    He, Xiyang; Zhang, Xiaohong; Tang, Long; Liu, Wanke

    2015-12-22

    Many applications, such as marine navigation, land vehicles location, etc., require real time precise positioning under medium or long baseline conditions. In this contribution, we develop a model of real-time kinematic decimeter-level positioning with BeiDou Navigation Satellite System (BDS) triple-frequency signals over medium distances. The ambiguities of two extra-wide-lane (EWL) combinations are fixed first, and then a wide lane (WL) combination is reformed based on the two EWL combinations for positioning. Theoretical analysis and empirical analysis is given of the ambiguity fixing rate and the positioning accuracy of the presented method. The results indicate that the ambiguity fixing rate can be up to more than 98% when using BDS medium baseline observations, which is much higher than that of dual-frequency Hatch-Melbourne-Wübbena (HMW) method. As for positioning accuracy, decimeter level accuracy can be achieved with this method, which is comparable to that of carrier-smoothed code differential positioning method. Signal interruption simulation experiment indicates that the proposed method can realize fast high-precision positioning whereas the carrier-smoothed code differential positioning method needs several hundreds of seconds for obtaining high precision results. We can conclude that a relatively high accuracy and high fixing rate can be achieved for triple-frequency WL method with single-epoch observations, displaying significant advantage comparing to traditional carrier-smoothed code differential positioning method.

  16. Instantaneous Real-Time Kinematic Decimeter-Level Positioning with BeiDou Triple-Frequency Signals over Medium Baselines

    Directory of Open Access Journals (Sweden)

    Xiyang He

    2015-12-01

    Full Text Available Many applications, such as marine navigation, land vehicles location, etc., require real time precise positioning under medium or long baseline conditions. In this contribution, we develop a model of real-time kinematic decimeter-level positioning with BeiDou Navigation Satellite System (BDS triple-frequency signals over medium distances. The ambiguities of two extra-wide-lane (EWL combinations are fixed first, and then a wide lane (WL combination is reformed based on the two EWL combinations for positioning. Theoretical analysis and empirical analysis is given of the ambiguity fixing rate and the positioning accuracy of the presented method. The results indicate that the ambiguity fixing rate can be up to more than 98% when using BDS medium baseline observations, which is much higher than that of dual-frequency Hatch-Melbourne-Wübbena (HMW method. As for positioning accuracy, decimeter level accuracy can be achieved with this method, which is comparable to that of carrier-smoothed code differential positioning method. Signal interruption simulation experiment indicates that the proposed method can realize fast high-precision positioning whereas the carrier-smoothed code differential positioning method needs several hundreds of seconds for obtaining high precision results. We can conclude that a relatively high accuracy and high fixing rate can be achieved for triple-frequency WL method with single-epoch observations, displaying significant advantage comparing to traditional carrier-smoothed code differential positioning method.

  17. Desflurane Allows for a Faster Emergence when Compared to Sevoflurane Without Affecting the Baseline Cognitive Recovery Time.

    Directory of Open Access Journals (Sweden)

    Joseph G. Werner

    2015-10-01

    Full Text Available Aims, We compared the effect of desflurane and sevoflurane on anesthesia recovery time in patients undergoing urological cystoscopic surgery. The Short Orientation Memory Concentration Test (SOMCT measured and compared cognitive impairment between groups and coughing was assessed throughout the anesthetic.Methods and Materials, This investigation included 75 ambulatory patients. Patients were randomized to receive either desflurane or sevoflurane. Inhalational anesthetics were discontinued after removal of the cystoscope and once repositioning of the patient was final. Coughing assessment and awakening time from anesthesia were assessed by a blinded observer.Statistical analysis used: Statistical analysis was performed by using t-test for parametric variables and Mann-Whitney U test for nonparametric variables. Results, The primary endpoint, mean time to eye-opening, was 5.0±2.5 minutes for desflurane, and 7.9±4.1 minutes for sevoflurane (p <0.001. There were no significant differences in time to SOMCT recovery (p=0.109, overall time spent in the post anesthesia care unit (p=0.924 or time to discharge (p=0.363. Median time until readiness for discharge was nine minutes in the desflurane group, while the sevoflurane group had a median time of 20 minutes (p=0.020. The overall incidence of coughing during the perioperative period was significantly higher in the desflurane (p=0.030. Conclusions, We re-confirmed that patients receiving desflurane had a faster emergence and met the criteria to be discharged from the post anesthesia care unit earlier. No difference was found in time to return to baseline cognition between desflurane and sevoflurane.

  18. Evaluation of the fibromyalgia impact questionnaire at baseline as a predictor for time to pain improvement in two clinical trials of pregabalin.

    Science.gov (United States)

    Bushmakin, A G; Cappelleri, J C; Chandran, A B; Zlateva, G

    2013-01-01

    The Fibromyalgia Impact Questionnaire (FIQ) is a patient-reported outcome that evaluates the impact of fibromyalgia (FM) on daily life. This study evaluated the relationships between the functional status of FM patients, measured with the FIQ at baseline, and median time to a clinically relevant pain reduction. Data were derived from two randomised, placebo-controlled trials that evaluated pregabalin 300, 450 and 600 mg/day for the treatment of FM. The Kaplan-Meier (nonparametric) method was applied to estimate median times to 'transient' and 'stable' events. The transient event was defined as a ≥ 27.9% improvement on an 11-point daily pain diary scale (0 = no pain, 10 = worst possible pain), and the stable event was defined as the mean of the daily improvements ≥ 27.9% relative to baseline over the subsequent study duration starting on the day of the transient event. A parametric model using time-to-event analysis was developed for evaluating the relationship between baseline FIQ score and the median time to these events. Median time was longer among patients treated with placebo relative to pregabalin for the transient events (11-12 days vs. 5-7 days) and stable events (86 days vs. 13-29 days). A significant association was observed between baseline FIQ scores and median time to transient and stable events (p FIQ scores of 10, and 9.1-9.6 days for FIQ scores of 100; for stable pain reduction events, the median time ranged from 11.0 to 13.0 days and from 27.0 to 28.5 days for baseline FIQ scores of 10 and 100 respectively. Time to a clinically relevant reduction in pain was significantly associated with FM severity at baseline as measured by the FIQ. Such an analysis can inform patient and physician expectations in clinical practice. © 2012 Blackwell Publishing Ltd.

  19. Hot flush frequency and severity at baseline as predictors of time to transient and stable treatment success: pooled analysis of two CE/BZA studies.

    Science.gov (United States)

    Pinkerton, JoAnn V; Bushmakin, Andrew G; Bobula, Joel; Lavenberg, Joanne; Komm, Barry S; Abraham, Lucy

    2017-12-01

    To evaluate the impact of baseline hot flush frequency and severity on time to symptom improvement during treatment with conjugated estrogens/bazedoxifene (CE/BZA). Data were pooled through week 12 from two randomized placebo-controlled trials (SMART-1 and SMART-2) of nonhysterectomized postmenopausal women with hot flushes treated with CE 0.45 mg/BZA 20 mg or CE 0.625 mg/BZA 20 mg. Time to transient and stable improvement (≥ 50% reduction in hot flush frequency/severity) was estimated using nonparametric models. Transient improvement in hot flush frequency occurred earlier in women treated with CE 0.45 mg/BZA 20 mg with less frequent versus more frequent baseline hot flushes per day: median time to transient improvement was 2, 7, and 11 days for women with hot flushes per day at baseline, respectively (P = 0.0009). Transient improvement in severity occurred earlier for women with less severe versus more severe baseline hot flushes: median time to transient improvement was 2, 6, and 16 days for women with mild, moderate, and severe hot flushes at baseline, respectively (P hot flushes take longer to achieve transient improvements with CE/BZA and should be encouraged to continue treatment, as it may take longer than a few weeks to achieve significant improvement.

  20. Baseline rationing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    The standard problem of adjudicating conflicting claims describes a situation in which a given amount of a divisible good has to be allocated among agents who hold claims against it exceeding the available amount. This paper considers more general rationing problems in which, in addition to claims...... to international protocols for the reduction of greenhouse emissions, or water distribution in drought periods. We define a family of allocation methods for such general rationing problems - called baseline rationing rules - and provide an axiomatic characterization for it. Any baseline rationing rule within...... the family is associated with a standard rule and we show that if the latter obeys some properties reflecting principles of impartiality, priority and solidarity, the former obeys them too....

  1. Deep sequencing analysis of HIV-1 reverse transcriptase at baseline and time of failure in patients receiving rilpivirine in the phase III studies ECHO and THRIVE.

    Science.gov (United States)

    Van Eygen, Veerle; Thys, Kim; Van Hove, Carl; Rimsky, Laurence T; De Meyer, Sandra; Aerssens, Jeroen; Picchio, Gaston; Vingerhoets, Johan

    2016-05-01

    Minority variants (1.0-25.0%) were evaluated by deep sequencing (DS) at baseline and virological failure (VF) in a selection of antiretroviral treatment-naïve, HIV-1-infected patients from the rilpivirine ECHO/THRIVE phase III studies. Linkage between frequently emerging resistance-associated mutations (RAMs) was determined. DS (llIumina®) and population sequencing (PS) results were available at baseline for 47 VFs and time of failure for 48 VFs; and at baseline for 49 responders matched for baseline characteristics. Minority mutations were accurately detected at frequencies down to 1.2% of the HIV-1 quasispecies. No baseline minority rilpivirine RAMs were detected in VFs; one responder carried 1.9% F227C. Baseline minority mutations associated with resistance to other non-nucleoside reverse transcriptase inhibitors (NNRTIs) were detected in 8/47 VFs (17.0%) and 7/49 responders (14.3%). Baseline minority nucleoside/nucleotide reverse transcriptase inhibitor (NRTI) RAMs M184V and L210W were each detected in one VF (none in responders). At failure, two patients without NNRTI RAMs by PS carried minority rilpivirine RAMs K101E and/or E138K; and five additional patients carried other minority NNRTI RAMs V90I, V106I, V179I, V189I, and Y188H. Overall at failure, minority NNRTI RAMs and NRTI RAMs were found in 29/48 (60.4%) and 16/48 VFs (33.3%), respectively. Linkage analysis showed that E138K and K101E were usually not observed on the same viral genome. In conclusion, baseline minority rilpivirine RAMs and other NNRTI/NRTI RAMs were uncommon in the rilpivirine arm of the ECHO and THRIVE studies. DS at failure showed emerging NNRTI resistant minority variants in seven rilpivirine VFs who had no detectable NNRTI RAMs by PS. © 2015 Wiley Periodicals, Inc.

  2. Forest baseline and deforestation map of the Dominican Republic through the analysis of time series of MODIS data

    Directory of Open Access Journals (Sweden)

    Florencia Sangermano

    2015-09-01

    Full Text Available Deforestation is one of the major threats to habitats in the Dominican Republic. In this work we present a forest baseline for the year 2000 and a deforestation map for the year 2011. Maps were derived from Moderate Resolution Imaging Radiometer (MODIS products at 250 m resolution. The vegetation continuous fields product (MOD44B for the year 2000 was used to produce the forest baseline, while the vegetation indices product (MOD13Q1 was used to detect change between 2000 and 2011. Major findings based on the data presented here are reported in the manuscript “Habitat suitability and protection status of four species of amphibians in the Dominican Republic” (Sangermano et al., Appl. Geogr., [7].63, 2015, 55–65

  3. Variation in pre-treatment count lead time and its effect on baseline estimates of cage-level sea lice abundance.

    Science.gov (United States)

    Gautam, R; Boerlage, A S; Vanderstichel, R; Revie, C W; Hammell, K L

    2016-11-01

    Treatment efficacy studies typically use pre-treatment sea lice abundance as the baseline. However, the pre-treatment counting window often varies from the day of treatment to several days before treatment. We assessed the effect of lead time on baseline estimates, using historical data (2010-14) from a sea lice data management programme (Fish-iTrends). Data were aggregated at the cage level for three life stages: (i) chalimus, (ii) pre-adult and adult male and (iii) adult female. Sea lice counts were log-transformed, and mean counts by lead time relative to treatment day were computed and compared separately for each life stage, using linear mixed models. There were 1,658 observations (treatment events) from 56 sites in 5 Bay Management Areas. Our study showed that lead time had a significant effect on the estimated sea lice abundance, which was moderated by season. During the late summer and autumn periods, counting on the day of treatment gave significantly higher values than other days and would be a more appropriate baseline estimate, while during spring and early summer abundance estimates were comparable among counts within 5 days of treatment. A season-based lead time window may be most appropriate when estimating baseline sea lice levels. © 2016 John Wiley & Sons Ltd.

  4. Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

    International Nuclear Information System (INIS)

    Takao, Seishin; Miyamoto, Naoki; Matsuura, Taeko; Onimaru, Rikiya; Katoh, Norio; Inoue, Tetsuya; Sutherland, Kenneth Lee; Suzuki, Ryusuke; Shirato, Hiroki; Shimizu, Shinichi

    2016-01-01

    Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

  5. Experimental setup and commissioning baseline study in search of time-variations in beta-decay half-lives

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, Braden, E-mail: goddard.braden@gmail.com [Department of Nuclear Engineering, Khalifa University of Science, Technology & Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates); Hitt, George W. [Department of Nuclear Engineering, Khalifa University of Science, Technology & Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates); Department of Applied Mathematics and Science, Khalifa University of Science, Technology & Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates); Solodov, Alexander A. [Department of Nuclear Engineering, Khalifa University of Science, Technology & Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates); Bridi, Dorian; Isakovic, A.F. [Department of Applied Mathematics and Science, Khalifa University of Science, Technology & Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates); El-Khazali, Reyad [Department of Electrical and Computer Engineering, Khalifa University of Science, Technology & Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates); Abulail, Ayman, E-mail: aabulail@pi.ac.ae [Department of Applied Mathematics and Science, Khalifa University of Science, Technology & Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates)

    2016-03-11

    Recently there have been a number of investigations into whether the decay constant of a radioactive isotope can be influenced by external factors, such as the Earth–Sun distance or Solar flare activity. Positive claims suggest that annual oscillations of ~0.1% and accelerations of ~0.4% in the relative activity of beta-emitters coincide with the Earth–Sun distance and solar flare activity, respectively. Results from replication experiments have so far been conflicting. The main criticism of the measurements used to trace and quantify these effects is that the data is of poor quality or limited in scope. Data have often been collected as part of short duration weekly calibration measurements, measured with a single type of low precision detector, only using one isotope, and having no environmental conditions information (temperature, pressure, humidity) accompanying the radiation measurements. This paper describes the setup of a series of counting experiments commissioned for addressing these criticisms. Six dedicated detector systems (four different types) measuring six different isotopes ({sup 14}C, {sup 54}Mn, {sup 60}Co, {sup 90}Sr, {sup 204}Tl, and {sup 226}Ra) have been continuously collecting source activity synchronously with environmental data for a period of one month (April 2014). The results of this baseline commissioning study show that there are correlations between activity and environmental conditions for some detector types which are then quantified. The results also show that the one sigma counting uncertainties in all the detectors are less than 0.024% for a given 24 h period. After accounting for propagated uncertainties from corrections against correlations with environmental data, the ability to resolve 0.1% activity changes varies, from 8 min to 1.6 days, depending on the specific detector. All six experiments therefore, will have sufficient precision over the upcoming year to scrutinize claims of both annual activity oscillations and

  6. Baseline Geochemistry of Natural Occurring Methane and Saline Groundwater in an Area of Unconventional Shale Gas Development Through Time

    Science.gov (United States)

    Harkness, J.; Darrah, T.; Warner, N. R.; Whyte, C. J.; Moore, M. T.; Millot, R.; Kloppmann, W.; Jackson, R. B.; Vengosh, A.

    2017-12-01

    Naturally occurring methane is nearly ubiquitous in most sedimentary basins and delineating the effects of anthropogenic contamination sources from geogenic sources is a major challenge for evaluating the impact of unconventional shale gas development on water quality. This study employs a broadly integrated study of various geochemical techniques to investigate the geochemical variations of groundwater and surface water before, during, and after hydraulic fracturing.This approache combines inorganic geochemistry (major cations and anions), stable isotopes of select inorganic constituents including strontium (87Sr/86Sr), boron (δ11B), lithium (δ7Li), and carbon (δ13C-DIC), select hydrocarbon molecular (methane, ethane, propane, butane, and pentane) and isotopic tracers (δ13C-CH4, δ13C-C2H6), tritium (3H), and noble gas elemental and isotopic composition (He, Ne, Ar) to apportion natural and anthropogenic sources of natural gas and salt contaminants both before and after drilling. Methane above 1 ccSTP/L in groundwater samples awas strongly associated with elevated salinity (chloride >50 mg/L).The geochemical and isotopic analysis indicate saline groundwater originated via naturally occurring processes, presumably from the migration of deeper methane-rich brines that have interacted extensively with coal lithologies. The chemistry and gas compostion of both saline and fresh groundwater wells did not change following the installation of nearby shale-gas wells.The results of this study emphasize the value of baseline characterization of water quality in areas of fossil fuel exploration. Overall this study presents a comprehensive geochemical framework that can be used as a template for assessing the sources of elevated hydrocarbons and salts to water resources in areas potentially impacted by oil and gas development.

  7. Daily time spent indoors in German homes--baseline data for the assessment of indoor exposure of German occupants.

    Science.gov (United States)

    Brasche, Sabine; Bischof, Wolfgang

    2005-01-01

    Comprehensive time-activity studies, for use as a basis for estimates of personal exposure, are not readily available in Germany. This analysis of time spent indoors at home is based on data from "Dampness and mould in homes" (2000/ 2001)--a study of about 12,000 persons living in 5530 randomly selected apartments and houses in Germany. The results show the mean times per day people in Germany spend in their homes, classified by gender, age group, building location, city size, region, building type, owner-occupier status, number of people at home, smoking and ventilation habits, moisture emission and ill health factors such as asthma, allergy and number of acute respiratory infections per year. The overall mean time spent at home, 15.7 h per, is in accordance with results from US-American (15.6 h/day) and Canadian (15.8 h/day) human activity surveys carried out in the nineties, as well as being consistent with the German Environmental Survey (1990/92) and a small German study in 1987.

  8. Trend analysis of GIMMS and MODIS NDVI time series for establishing a land degradation neutrality national baseline

    Science.gov (United States)

    Gichenje, Helene; Godinho, Sergio

    2017-04-01

    Land degradation is a key global environment and development problem that is recognized as a priority by the international development community. The Sustainable Development Goals (SDGs) were adopted by the global community in 2015, and include a goal related to land degradation and the accompanying target to achieve a land degradation-neutral (LDN) world by 2030. The LDN concept encompasses two joint actions of reducing the rate of degradation and increasing the rate of restoration. Using Kenya as the study area, this study aims to develop and test a spatially explicit methodology for assessing and monitoring the operationalization of a land degradation neutrality scheme at the national level. Time series analysis is applied to Normalized Difference Vegetation Index (NDVI) satellite data records, based on the hypothesis that the resulting NDVI residual trend would enable successful detection of changes in vegetation photosynthetic capacity and thus serve as a proxy for land degradation and regeneration processes. Two NDVI data sets are used to identify the spatial and temporal distribution of degraded and regenerated areas: the long term coarse resolution (8km, 1982-2015) third generation Global Inventory Modeling and Mapping Studies (GIMMS) NDVI3g data record; and the shorter-term finer resolution (250m, 2001-2015) Moderate Resolution Imaging Spectroradiometer (MODIS) derived NDVI data record. Climate data (rainfall, temperature and soil moisture) are used to separate areas of human-induced vegetation productivity decline from those driven by climate dynamics. Further, weekly vegetation health (VH) indexes (4km, 1982-2015) developed by National Oceanic and Atmospheric Administration (NOAA), are assessed as indicators for early detection and monitoring of land degradation by estimating vegetation stress (moisture, thermal and combined conditions).

  9. HIV risk and behaviour among part-time versus professional FSW: baseline report of an interventional cohort in Burkina Faso.

    Science.gov (United States)

    Traore, Isidore T; Hema, Noelie M; Sanon, Anselme; Some, Felicien; Ouedraogo, Djeneba; Some, Roselyne; Niessougou, Josiane; Konate, Issouf; Mayaud, Philippe; Van De Perre, Philippe; Meda, Nicolas; Nagot, Nicolas

    2016-02-01

    To readjust HIV control programmes in Africa, we assessed the factors associated with high-risk behaviours and HIV infection among young female sex workers (FSW) in Burkina Faso. We carried out a cross-sectional study from September 2009 to September 2010 in Ouagadougou, the capital city. FSW were categorised as professionals and part-time sex workers (PTSW). After a face-to-face questionnaire, blood and urine samples were collected for HIV, HSV-2, genital infections and pregnancy. High-risk behaviour was defined as a recent unprotected sex with either casual clients, regular clients or regular partners. We recruited 609 FSW including 188 (30.9%) professionals. Their median age was 21 years (IQR 19-23), and the prevalence of HIV was 10.3% among professionals and 6.5% among PTSW. Only 3 of 46 HIV-infected women were aware of their status. Overall, 277 (45.6%) women reported high-risk behaviours (41.2% among professionals and 47.5% among PTSW), which were driven mainly by non-systematic condom use with regular partners. In multivariable analysis, PTSW (adjusted OR (AOR)=1.89; 95% CI 1.27 to 2.82) and having a primary (AOR=1.75; 95% CI 1.15 to 2.67) or higher education level (AOR=1.80; 95% CI 1.13 to 2.89) remained associated with high-risk behaviours. HIV infection was associated with older age (AOR=1.44; 95% CI 1.22 to 1.71), with being married/cohabiting (AOR=2.70; 95% CI 1.21 to 6.04) and with Trichomonas vaginalis infection (AOR=9.63; 95% CI 2.93 to 31.59), while history of HIV testing was associated with a decreased risk (AOR=0.18; 95% CI 0.08 to 0.40). This study highlights the need for targeted interventions among young FSW focusing particularly on PTSW, sexual behaviours with regular partners and regular HIV testing. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Baseline predictors of sputum culture conversion in pulmonary tuberculosis: importance of cavities, smoking, time to detection and W-Beijing genotype.

    Directory of Open Access Journals (Sweden)

    Marianne E Visser

    Full Text Available Time to detection (TTD on automated liquid mycobacterial cultures is an emerging biomarker of tuberculosis outcomes. The M. tuberculosis W-Beijing genotype is spreading globally, indicating a selective advantage. There is a paucity of data on the association between baseline TTD and W-Beijing genotype and tuberculosis outcomes.To assess baseline predictors of failure of sputum culture conversion, within the first 2 months of antitubercular therapy, in participants with pulmonary tuberculosis.Between May 2005 and August 2008 we conducted a prospective cohort study of time to sputum culture conversion in ambulatory participants with first episodes of smear and culture positive pulmonary tuberculosis attending two primary care clinics in Cape Town, South Africa. Rifampicin resistance (diagnosed on phenotypic susceptibility testing was an exclusion criterion. Sputum was collected weekly for 8 weeks for mycobacterial culture on liquid media (BACTEC MGIT 960. Due to missing data, multiple imputation was performed. Time to sputum culture conversion was analysed using a Cox-proportional hazards model. Bayesian model averaging determined the posterior effect probability for each variable.113 participants were enrolled (30.1% female, 10.5% HIV-infected, 44.2% W-Beijing genotype, and 89% cavities. On Kaplan Meier analysis 50.4% of participants underwent sputum culture conversion by 8 weeks. The following baseline factors were associated with slower sputum culture conversion: TTD (adjusted hazard ratio (aHR = 1.11, 95% CI 1.02; 1.2, lung cavities (aHR = 0.13, 95% CI 0.02; 0.95, ever smoking (aHR = 0.32, 95% CI 0.1; 1.02 and the W-Beijing genotype (aHR = 0.51, 95% CI 0.25; 1.07. On Bayesian model averaging, posterior probability effects were strong for TTD, lung cavitation and smoking and moderate for W-Beijing genotype.We found that baseline TTD, smoking, cavities and W-Beijing genotype were associated with delayed 2 month sputum culture

  11. Baseline predictors of sputum culture conversion in pulmonary tuberculosis: importance of cavities, smoking, time to detection and W-Beijing genotype.

    Science.gov (United States)

    Visser, Marianne E; Stead, Michael C; Walzl, Gerhard; Warren, Rob; Schomaker, Michael; Grewal, Harleen M S; Swart, Elizabeth C; Maartens, Gary

    2012-01-01

    Time to detection (TTD) on automated liquid mycobacterial cultures is an emerging biomarker of tuberculosis outcomes. The M. tuberculosis W-Beijing genotype is spreading globally, indicating a selective advantage. There is a paucity of data on the association between baseline TTD and W-Beijing genotype and tuberculosis outcomes. To assess baseline predictors of failure of sputum culture conversion, within the first 2 months of antitubercular therapy, in participants with pulmonary tuberculosis. Between May 2005 and August 2008 we conducted a prospective cohort study of time to sputum culture conversion in ambulatory participants with first episodes of smear and culture positive pulmonary tuberculosis attending two primary care clinics in Cape Town, South Africa. Rifampicin resistance (diagnosed on phenotypic susceptibility testing) was an exclusion criterion. Sputum was collected weekly for 8 weeks for mycobacterial culture on liquid media (BACTEC MGIT 960). Due to missing data, multiple imputation was performed. Time to sputum culture conversion was analysed using a Cox-proportional hazards model. Bayesian model averaging determined the posterior effect probability for each variable. 113 participants were enrolled (30.1% female, 10.5% HIV-infected, 44.2% W-Beijing genotype, and 89% cavities). On Kaplan Meier analysis 50.4% of participants underwent sputum culture conversion by 8 weeks. The following baseline factors were associated with slower sputum culture conversion: TTD (adjusted hazard ratio (aHR) = 1.11, 95% CI 1.02; 1.2), lung cavities (aHR = 0.13, 95% CI 0.02; 0.95), ever smoking (aHR = 0.32, 95% CI 0.1; 1.02) and the W-Beijing genotype (aHR = 0.51, 95% CI 0.25; 1.07). On Bayesian model averaging, posterior probability effects were strong for TTD, lung cavitation and smoking and moderate for W-Beijing genotype. We found that baseline TTD, smoking, cavities and W-Beijing genotype were associated with delayed 2 month sputum culture. Larger

  12. Denosumab and Bone Metastasis–Free Survival in Men With Nonmetastatic Castration-Resistant Prostate Cancer: Exploratory Analyses by Baseline Prostate-Specific Antigen Doubling Time

    Science.gov (United States)

    Smith, Matthew R.; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-01-01

    Purpose Denosumab, an anti–RANK ligand monoclonal antibody, significantly increases bone metastasis–free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. Patients and Methods A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. Results In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Conclusion Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression. PMID:24043751

  13. Denosumab and bone metastasis-free survival in men with nonmetastatic castration-resistant prostate cancer: exploratory analyses by baseline prostate-specific antigen doubling time.

    Science.gov (United States)

    Smith, Matthew R; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-10-20

    Denosumab, an anti-RANK ligand monoclonal antibody, significantly increases bone metastasis-free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression.

  14. Time of exposure to night work and carotid atherosclerosis: a structural equation modeling approach using baseline data from ELSA-Brasil.

    Science.gov (United States)

    Silva-Costa, Aline; Guimarães, Joanna; Chor, Dora; de Jesus Mendes da Fonseca, Maria; Bensenor, Isabela; Santos, Itamar; Barreto, Sandhi; Griep, Rosane Härter

    2018-04-02

    The study of cardiovascular diseases (CVD) associated with night work is difficult due to the long period required for conditions to manifest and the healthy-worker effect. Analyzing asymptomatic pre-clinical changes in the atherosclerotic process is a way to assess the pathways between exposure to night work and CVD. To evaluate the associations between night work and subclinical atherosclerosis measured by carotid intima-media thickness (CIMT) using baseline data from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil). We conducted cross-sectional analyses using baseline data (2008-2010) from 9785 civil servants, aged 35-74 years. The associations between time of exposure to night work and mean CIMT were examined using a structural equation model. The sample included 4259 men and 5526 women, mean age of 51.6 years. A total of 1778 (18.2%) individuals were exposed to night work (594 current and 1184 former night workers), and the mean years of night work exposed was 11.47 (SD = 9.45) years. On average, mean CIMT was 0.606 (SD = 0.130) mm. Among men, the increase in exposure to night work was significantly associated with an increase in BMI and CIMT. Among women, night work was not associated with increased CIMT. In relation to the indirect associations, results suggest a possible mediation by BMI, diabetes and hypertension on the association between the years of night work and mean CIMT only among men. Night work was associated with increased CIMT only among men. These findings add to the knowledge of the possible pathways that link night work and carotid atherosclerosis. Additionally, these results contribute to the recognition of work schedules as a public health problem that should be addressed by the medical community and policy makers.

  15. Leisure-time physical activity, sedentary behaviors, sleep, and cardiometabolic risk factors at baseline in the PREDIMED-PLUS intervention trial: A cross-sectional analysis.

    Directory of Open Access Journals (Sweden)

    Nuria Rosique-Esteban

    Full Text Available Limited data exists on the interrelationships between physical activity (PA, sedentary behaviors and sleep concerning cardiometabolic risk factors in aged adults at high cardiovascular disease risk. Our aim was to examine independent and joint associations between time spent in leisure-time PA, sedentary behaviors and sleep on the prevalence of obesity, type 2 diabetes (T2D and components of the metabolic syndrome (MetS in Mediterranean individuals at high cardiovascular risk. Cross-sectional analyses were performed on baseline data from 5776 Spanish adults (aged 55-75y in men; 60-75y in women with overweight/obesity and MetS, from October 2013 to October 2016, in the PREDIMED-PLUS trial. Employing multivariable-adjusted Cox regression with robust variance and constant time (given the cross-sectional design, higher prevalence of obesity, T2D and abdominal obesity as component of the MetS were associated with greater time in TV-viewing (Relative Risk, RR: 1.02, 95%CI: 1.01, 1.03; RR:1.04, 95%CI: 1.02, 1.06 and RR: 1.01 95%CI: 1.00, 1.02; respectively, all P < .01. Conversely, greater time in moderate-vigorous PA (MVPA was associated with lower prevalence of obesity, T2D, abdominal obesity and low HDL-cholesterol (RR: 0.95, 95%CI: 0.93, 0.97; RR: 0.94, 95%CI: 0.89, 0.99; RR: 0.97, 95%CI: 0.96, 0.98; and RR: 0.95, 95%CI: 0.91, 0.99, respectively, all P < .05. For these outcomes, theoretically substituting 1-h/day of MVPA for 1-h/day TV-viewing was also significantly associated with lower prevalence (RR 0.91 to 0.97, all P < .05. Similar lower RR in these outcomes was observed when substituting 1-h/day of MVPA for 1-h/day of sleeping. Longer time watching TV and not meeting MVPA recommendations were jointly associated with higher RR of the prevalence of obesity and T2D. We concluded that, in senior individuals at high cardiovascular risk, greater time spent on MVPA and fewer on sedentary behaviors was inversely associated with prevalence of obesity

  16. Correlates of time spent walking and cycling to and from work: baseline results from the commuting and health in Cambridge study

    Directory of Open Access Journals (Sweden)

    Panter Jenna

    2011-11-01

    Full Text Available Abstract Purpose Environmental perceptions and psychological measures appear to be associated with walking and cycling behaviour; however, their influence is still unclear. We assessed these associations using baseline data from a quasi-experimental cohort study of the effects of major transport infrastructural developments in Cambridge, UK. Methods Postal surveys were sent to adults who travel to work in Cambridge (n = 1582. Questions asked about travel modes and time spent travelling to and from work in the last week, perceptions of the route, psychological measures regarding car use and socio-demographic characteristics. Participants were classified into one of two categories according to time spent walking for commuting ('no walking' or 'some walking' and one of three categories for cycling ('no cycling', '1-149 min/wk' and ' ≥ 150 min/wk'. Results Of the 1164 respondents (68% female, mean (SD age: 42.3 (11.4 years 30% reported any walking and 53% reported any cycling to or from work. In multiple regression models, short distance to work and not having access to a car showed strong positive associations with both walking and cycling. Furthermore, those who reported that it was pleasant to walk were more likely to walk to or from work (OR = 4.18, 95% CI 3.02 to 5.78 and those who reported that it was convenient to cycle on the route between home and work were more likely to do so (1-149 min/wk: OR = 4.60, 95% CI 2.88 to 7.34; ≥ 150 min/wk: OR = 3.14, 95% CI 2.11 to 4.66. Positive attitudes in favour of car use were positively associated with time spent walking to or from work but negatively associated with cycling to or from work. Strong perceived behavioural control for car use was negatively associated with walking. Conclusions In this relatively affluent sample of commuters, a range of individual and household characteristics, perceptions of the route environment and psychological measures relating to car use were associated with

  17. Baseline Levels, and Changes Over Time in Body Mass Index and Fasting Insulin, and Their Relationship to Change in Metabolic Trait Clustering

    Science.gov (United States)

    Sullivan, Lisa M.; Fox, Caroline S.; Wilson, Peter W.F.; Nathan, David M.; Vasan, Ramachandran S.; D'Agostino, Ralph B.; Meigs, James B.

    2014-01-01

    Abstract Background: Multiple abnormal metabolic traits are found together or “cluster” within individuals more often than is predicted by chance. The individual and combined role of adiposity and insulin resistance (IR) on metabolic trait clustering is uncertain. We tested the hypothesis that change in trait clustering is a function of both baseline level and change in these measures. Methods: In 2616 nondiabetic Framingham Offspring Study participants, body mass index (BMI) and fasting insulin were related to a within-person 7-year change in a trait score of 0–4 Adult Treatment Panel III metabolic syndrome traits (hypertension, high triglycerides, low high-density lipoprotein cholesterol, hyperglycemia). Results: At baseline assessment, mean trait score was 1.4 traits, and 7-year mean (SEM) change in trait score was +0.25 (0.02) traits, Pfasting insulin were similarly related to trait score change. In models adjusted for age–sex–baseline cluster score, 7-year change in trait score was significantly related to both a 1-quintile difference in baseline BMI (0.07 traits) and fasting insulin (0.18 traits), and to both a 1-quintile 7-year increase in BMI (0.21 traits) and fasting insulin (0.18 traits). Conclusions: Change in metabolic trait clustering was significantly associated with baseline levels and changes in both BMI and fasting insulin, highlighting the importance of both obesity and IR in the clustering of metabolic traits. PMID:25007010

  18. Baseline Goblet Cell Mucin Secretion in the Airways Exceeds Stimulated Secretion over Extended Time Periods, and Is Sensitive to Shear Stress and Intracellular Mucin Stores.

    Directory of Open Access Journals (Sweden)

    Yunxiang Zhu

    Full Text Available Airway mucin secretion studies have focused on goblet cell responses to exogenous agonists almost to the exclusion of baseline mucin secretion (BLMS. In human bronchial epithelial cell cultures (HBECCs, maximal agonist-stimulated secretion exceeds baseline by ~3-fold as measured over hour-long periods, but mucin stores are discharged completely and require 24 h for full restoration. Hence, over 24 h, total baseline exceeds agonist-induced secretion by several-fold. Studies with HBECCs and mouse tracheas showed that BLMS is highly sensitive to mechanical stresses. Harvesting three consecutive 1 h baseline luminal incubations with HBECCs yielded equal rates of BLMS; however, lengthening the middle period to 72 h decreased the respective rate significantly, suggesting a stimulation of BLMS by the gentle washes of HBECC luminal surfaces. BLMS declined exponentially after washing HBECCs (t1/2 = 2.75 h, to rates approaching zero. HBECCs exposed to low perfusion rates exhibited spike-like increases in BLMS when flow was jumped 5-fold: BLMS increased >4 fold, then decreased within 5 min to a stable plateau at 1.5-2-fold over control. Higher flow jumps induced proportionally higher BLMS increases. Inducing mucous hyperplasia in HBECCs increased mucin production, BLMS and agonist-induced secretion. Mouse tracheal BLMS was ~6-fold higher during perfusion, than when flow was stopped. Munc13-2 null mouse tracheas, with their defect of accumulated cellular mucins, exhibited similar BLMS as WT, contrary to predictions of lower values. Graded mucous metaplasia induced in WT and Munc13-2 null tracheas with IL-13, caused proportional increases in BLMS, suggesting that naïve Munc13-2 mouse BLMS is elevated by increased mucin stores. We conclude that BLMS is, [i] a major component of mucin secretion in the lung, [ii] sustained by the mechanical activity of a dynamic lung, [iii] proportional to levels of mucin stores, and [iv] regulated differentially from agonist

  19. Baseline Goblet Cell Mucin Secretion in the Airways Exceeds Stimulated Secretion over Extended Time Periods, and Is Sensitive to Shear Stress and Intracellular Mucin Stores

    Science.gov (United States)

    Doyle, Sean P.; Nguyen, Kristine; Ribeiro, Carla M. P.; Vasquez, Paula A.; Forest, M. Gregory; Lethem, Michael I.; Dickey, Burton F.; Davis, C. William

    2015-01-01

    Airway mucin secretion studies have focused on goblet cell responses to exogenous agonists almost to the exclusion of baseline mucin secretion (BLMS). In human bronchial epithelial cell cultures (HBECCs), maximal agonist-stimulated secretion exceeds baseline by ~3-fold as measured over hour-long periods, but mucin stores are discharged completely and require 24 h for full restoration. Hence, over 24 h, total baseline exceeds agonist-induced secretion by several-fold. Studies with HBECCs and mouse tracheas showed that BLMS is highly sensitive to mechanical stresses. Harvesting three consecutive 1 h baseline luminal incubations with HBECCs yielded equal rates of BLMS; however, lengthening the middle period to 72 h decreased the respective rate significantly, suggesting a stimulation of BLMS by the gentle washes of HBECC luminal surfaces. BLMS declined exponentially after washing HBECCs (t1/2 = 2.75 h), to rates approaching zero. HBECCs exposed to low perfusion rates exhibited spike-like increases in BLMS when flow was jumped 5-fold: BLMS increased >4 fold, then decreased within 5 min to a stable plateau at 1.5–2-fold over control. Higher flow jumps induced proportionally higher BLMS increases. Inducing mucous hyperplasia in HBECCs increased mucin production, BLMS and agonist-induced secretion. Mouse tracheal BLMS was ~6-fold higher during perfusion, than when flow was stopped. Munc13-2 null mouse tracheas, with their defect of accumulated cellular mucins, exhibited similar BLMS as WT, contrary to predictions of lower values. Graded mucous metaplasia induced in WT and Munc13-2 null tracheas with IL-13, caused proportional increases in BLMS, suggesting that naïve Munc13-2 mouse BLMS is elevated by increased mucin stores. We conclude that BLMS is, [i] a major component of mucin secretion in the lung, [ii] sustained by the mechanical activity of a dynamic lung, [iii] proportional to levels of mucin stores, and [iv] regulated differentially from agonist-induced mucin

  20. Program reference schedule baseline

    International Nuclear Information System (INIS)

    1986-07-01

    This Program Reference Schedule Baseline (PRSB) provides the baseline Program-level milestones and associated schedules for the Civilian Radioactive Waste Management Program. It integrates all Program-level schedule-related activities. This schedule baseline will be used by the Director, Office of Civilian Radioactive Waste Management (OCRWM), and his staff to monitor compliance with Program objectives. Chapter 1 includes brief discussions concerning the relationship of the PRSB to the Program Reference Cost Baseline (PRCB), the Mission Plan, the Project Decision Schedule, the Total System Life Cycle Cost report, the Program Management Information System report, the Program Milestone Review, annual budget preparation, and system element plans. Chapter 2 includes the identification of all Level 0, or Program-level, milestones, while Chapter 3 presents and discusses the critical path schedules that correspond to those Level 0 milestones

  1. Long Baseline Observatory (LBO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Long Baseline Observatory (LBO) comprises ten radio telescopes spanning 5,351 miles. It's the world's largest, sharpest, dedicated telescope array. With an eye...

  2. Studies on Instabilities in Long-Baseline Two-Way Satellite Time and Frequency Transfer (TWSTFT) Including a Troposphere Delay Model

    Science.gov (United States)

    2007-11-01

    281.4 -281.2 -281.0 MJD 54270.0 to 54277.0 (June 2007) MJD 53767.0 to 53773.0 (Feb 2006) S ag na c de la y N IC T to P TB (n s) days from MJD...standards in Europe and the US at the 10-15 uncertainty level,” Metrologia , 43, 109-120. [2] D. Piester, A. Bauch, L. Breakiron, D. Matsakis, B...Blanzano, and O. Koudelka, 2008, “Time transfer with nanosecond accuracy for the realization of International Atomic Time,” submitted to Metrologia

  3. First Grade Baseline Evaluation

    Science.gov (United States)

    Center for Innovation in Assessment (NJ1), 2013

    2013-01-01

    The First Grade Baseline Evaluation is an optional tool that can be used at the beginning of the school year to help teachers get to know the reading and language skills of each student. The evaluation is composed of seven screenings. Teachers may use the entire evaluation or choose to use those individual screenings that they find most beneficial…

  4. Integrated planning: A baseline development perspective

    International Nuclear Information System (INIS)

    Clauss, L.; Chang, D.

    1994-01-01

    The FEMP Baseline establishes the basis for integrating environmental activity technical requirements with their cost and schedule elements. The result is a path forward to successfully achieving the FERMCO mission. Specific to cost management, the FEMP Baseline has been incorporate into the FERMCO Project Control System (PCS) to provide a time-phased budget plan against which contractor performance is measured with an earned value management system. The result is the Performance Measurement Baseline (PMB), an important tool for keeping cost under control

  5. Leisure-time physical activity and risk of disability incidence: A 12-year prospective cohort study among young elderly of the same age at baseline.

    Science.gov (United States)

    Matsunaga, Takashi; Naito, Mariko; Wakai, Kenji; Ukawa, Shigekazu; Zhao, Wenjing; Okabayashi, Satoe; Ando, Masahiko; Kawamura, Takashi; Tamakoshi, Akiko

    2017-11-01

    To clarify the role of physical activity in preventing disability in Japan, we investigated the association between amount of leisure-time physical activity and incidence of disability among the young elderly. In the New Integrated Suburban Seniority Investigation (NISSIN) project conducted from 1996 to 2013, we followed 2888 community-dwelling adults aged 64-65 years with no history of cerebrovascular disease for a median follow-up of 11.6 years. Disabilities were defined as follows based on the classifications of the Japanese long-term care insurance system: 1) support or care levels (support levels 1-2 or care levels 1-5); 2) care levels 2-5; 3) support or care levels with dementia; and 4) care levels 2-5 or death. In addition, we also assessed 5) all-cause mortality. After controlling for sociodemographic, lifestyle, and medical factors, male participants reporting an activity level of 18.1 metabolic equivalent (MET)-hours/week (the median among those with activities) or more had 52% less risk of being classified as support or care levels with dementia compared with the no activity group (hazard ratio 0.48; 95% confidence interval, 0.25-0.94). No significant association was found among women between amount of leisure-time physical activity and incidence of disability. We identified an inverse dose-response relationship between the amount of leisure-time physical activity and the risk of disability with dementia in men. Therefore, a higher level of physical activity should be recommended to young elderly men to prevent disability with dementia. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  6. Rationing with baselines

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter Raahave

    2013-01-01

    We introduce a new operator for general rationing problems in which, besides conflicting claims, individual baselines play an important role in the rationing process. The operator builds onto ideas of composition, which are not only frequent in rationing, but also in related problems...... such as bargaining, choice, and queuing. We characterize the operator and show how it preserves some standard axioms in the literature on rationing. We also relate it to recent contributions in such literature....

  7. The TDAQ Baseline Architecture

    CERN Multimedia

    Wickens, F J

    The Trigger-DAQ community is currently busy preparing material for the DAQ, HLT and DCS TDR. Over the last few weeks a very important step has been a series of meetings to complete agreement on the baseline architecture. An overview of the architecture indicating some of the main parameters is shown in figure 1. As reported at the ATLAS Plenary during the February ATLAS week, the main area where the baseline had not yet been agreed was around the Read-Out System (ROS) and details in the DataFlow. The agreed architecture has: Read-Out Links (ROLs) from the RODs using S-Link; Read-Out Buffers (ROB) sited near the RODs, mounted in a chassis - today assumed to be a PC, using PCI bus at least for configuration, control and monitoring. The baseline assumes data aggregation, in the ROB and/or at the output (which could either be over a bus or in the network). Optimization of the data aggregation will be made in the coming months, but the current model has each ROB card receiving input from 4 ROLs, and 3 such c...

  8. Baseline budgeting for continuous improvement.

    Science.gov (United States)

    Kilty, G L

    1999-05-01

    This article is designed to introduce the techniques used to convert traditionally maintained department budgets to baseline budgets. This entails identifying key activities, evaluating for value-added, and implementing continuous improvement opportunities. Baseline Budgeting for Continuous Improvement was created as a result of a newly named company president's request to implement zero-based budgeting. The president was frustrated with the mind-set of the organization, namely, "Next year's budget should be 10 to 15 percent more than this year's spending." Zero-based budgeting was not the answer, but combining the principles of activity-based costing and the Just-in-Time philosophy of eliminating waste and continuous improvement did provide a solution to the problem.

  9. 2017 Annual Technology Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hand, M. M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Eberle, Annika [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Beiter, Philipp C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kurup, Parthiv [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Turchi, Craig S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Feldman, David J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Augustine, Chad R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maness, Michael [Formerly NREL; O' Connor, Patrick [Oak Ridge National Laboratory

    2018-03-26

    Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts as well as information from the Energy Information Administration for fuel-based technologies. The ATB has been reviewed by experts and it includes the following electricity generation technologies: land-based wind, offshore wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, coal, natural gas, nuclear, and conventional biopower. This webinar presentation introduces the 2017 ATB.

  10. Biofuels Baseline 2008

    Energy Technology Data Exchange (ETDEWEB)

    Hamelinck, C.; Koper, M.; Berndes, G.; Englund, O.; Diaz-Chavez, R.; Kunen, E.; Walden, D.

    2011-10-15

    The European Union is promoting the use of biofuels and other renewable energy in transport. In April 2009, the Renewable Energy Directive (2009/28/EC) was adopted that set a 10% target for renewable energy in transport in 2020. The directive sets several requirements to the sustainability of biofuels marketed in the frame of the Directive. The Commission is required to report to the European Parliament on a regular basis on a range of sustainability impacts resulting from the use of biofuels in the EU. This report serves as a baseline of information for regular monitoring on the impacts of the Directive. Chapter 2 discusses the EU biofuels market, the production and consumption of biofuels and international trade. It is derived where the feedstock for EU consumed biofuels originally come from. Chapter 3 discusses the biofuel policy framework in the EU and major third countries of supply. It looks at various policy aspects that are relevant to comply with the EU sustainability requirements. Chapter 4 discusses the environmental and social sustainability aspects associated with EU biofuels and their feedstock. Chapter 5 discusses the macro-economic effects that indirectly result from increased EU biofuels consumption, on commodity prices and land use. Chapter 6 presents country factsheets for main third countries that supplied biofuels to the EU market in 2008.

  11. Baseline conditions at Olkiluoto

    International Nuclear Information System (INIS)

    2003-09-01

    The main purpose of this report is to establish a reference point - defined as the data collected up until the end of year 2002 - for the coming phases of the Finnish spent nuclear fuel disposal programme. The focus is: to define the current surface and underground conditions at the site, both as regards the properties for which a change is expected and for the properties which are of particular interest for long-term safety or environmental impact; to establish, as far as possible, the natural fluctuation of properties that are potentially affected by construction of the underground laboratory, the ONKALO, and to provide references to data on parameters or use in model development and testing and to use models to assist in understanding and interpreting the data. The emphasis of the baseline description is on bedrock characteristics that are relevant to the long-term safety of a spent fuel repository and, hence, to include the hydrogeological, hydrogeochemical, rock mechanical, tectonic and seismic conditions of the site. The construction of the ONKALO will also affect some conditions on the surface, and, therefore, a description of the main characteristics of the nature and the man-made constructions at Olkiluoto is also given. This report is primarily a road map to the available information on the prevailing conditions at the Olkiluoto site and a framework for understanding of data collected. Hence, it refers to numerous available background reports and other archived information produced over the past 20 years or more, and forms a recapitulation and revaluation of the characterisation data of the Olkiluoto site. (orig.)

  12. A long baseline global stereo matching based upon short baseline estimation

    Science.gov (United States)

    Li, Jing; Zhao, Hong; Li, Zigang; Gu, Feifei; Zhao, Zixin; Ma, Yueyang; Fang, Meiqi

    2018-05-01

    In global stereo vision, balancing the matching efficiency and computing accuracy seems to be impossible because they contradict each other. In the case of a long baseline, this contradiction becomes more prominent. In order to solve this difficult problem, this paper proposes a novel idea to improve both the efficiency and accuracy in global stereo matching for a long baseline. In this way, the reference images located between the long baseline image pairs are firstly chosen to form the new image pairs with short baselines. The relationship between the disparities of pixels in the image pairs with different baselines is revealed by considering the quantized error so that the disparity search range under the long baseline can be reduced by guidance of the short baseline to gain matching efficiency. Then, the novel idea is integrated into the graph cuts (GCs) to form a multi-step GC algorithm based on the short baseline estimation, by which the disparity map under the long baseline can be calculated iteratively on the basis of the previous matching. Furthermore, the image information from the pixels that are non-occluded under the short baseline but are occluded for the long baseline can be employed to improve the matching accuracy. Although the time complexity of the proposed method depends on the locations of the chosen reference images, it is usually much lower for a long baseline stereo matching than when using the traditional GC algorithm. Finally, the validity of the proposed method is examined by experiments based on benchmark datasets. The results show that the proposed method is superior to the traditional GC method in terms of efficiency and accuracy, and thus it is suitable for long baseline stereo matching.

  13. Performance Measurement Baseline Change Request

    Data.gov (United States)

    Social Security Administration — The Performance Measurement Baseline Change Request template is used to document changes to scope, cost, schedule, or operational performance metrics for SSA's Major...

  14. Deriving a time series of 3D glacier motion to investigate interactions of a large mountain glacial system with its glacial lake: Use of Synthetic Aperture Radar Pixel Offset-Small Baseline Subset technique

    Science.gov (United States)

    Li, Jia; Li, Zhi-wei; Wu, Li-xin; Xu, Bing; Hu, Jun; Zhou, Yu-shan; Miao, Ze-lang

    2018-04-01

    We investigated the interactions of Lake Merzbacher with the Southern Inylchek Glacier (Central Tien Shan) using the Synthetic Aperture Radar (SAR) Pixel Offset-Small Baseline Subset (PO-SBAS) to derive a time series of three-dimensional (3D) glacier motion. The measurements of 3D glacier velocity were ∼17% more precise than a previous study that did not use the SBAS estimation. The velocities of the glacier were up to 58 cm/day east, 70 cm/day north, and 113 cm/day vertically. Combining these data with Landsat images indicated that movement of the glacier is sensitive to changes of Lake Merzbacher. Specifically, the entry of more lake water into the glacier during the ablation season increased englacial ablation due to thermal erosion. Moreover, ice calving begins when the lake water gradually lifts the ice dam. Calving can cause greater loss of glacier mass than normal ablation. Trying to replenish the front mass loss, the distributary accelerates and the mass loss further intensifies. A time series of the vertical velocity indicates that the glacier tongue has a huge englacial cavity. We suggest that the lake outburst is directly related to the crack of this cavity. Bursting of the lake triggers a mini-surge at the glacier tongue. The vertical velocity at the ice dam was ∼+60 cm/day before the lake outburst, and ∼-113 cm/day afterwards. After drainage of the lake, flow velocities at the distributary, do not sharply decrease because pre-drainage mass loss needs to be replenished by fast flow. Based on comparisons with previous measurements, our results indicate that the lake had an increasing influence on the glacier from 2005 to 2009. This study demonstrates that a time series of 3D glacier motion based on the PO-SBAS technique is effective for assessing the dynamics of a mountain glacial system and interactions with its glacial lake.

  15. THE US LONG BASELINE NEUTRINO EXPERIMENT STUDY.

    Energy Technology Data Exchange (ETDEWEB)

    BISHAI,M.

    2007-08-06

    The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory (BNL)and Fermi National Accelerator Laboratory (FNAL) to investigate the potential for future U.S. based long baseline neutrino oscillation experiments using MW class conventional neutrino beams that can be produced at FNAL. The experimental baselines are based on two possible detector locations: (1) off-axis to the existing FNAL NuMI beamline at baselines of 700 to 810 km and (2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from FNAL aimed at a massive detector with a baseline of > 1000km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2{sup o}.

  16. DairyBISS Baseline report

    NARCIS (Netherlands)

    Buizer, N.N.; Berhanu, Tinsae; Murutse, Girmay; Vugt, van S.M.

    2015-01-01

    This baseline report of the Dairy Business Information Service and Support (DairyBISS) project presents the findings of a baseline survey among 103 commercial farms and 31 firms and advisors working in the dairy value chain. Additional results from the survey among commercial dairy farms are

  17. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  18. The California Baseline Methane Survey

    Science.gov (United States)

    Duren, R. M.; Thorpe, A. K.; Hopkins, F. M.; Rafiq, T.; Bue, B. D.; Prasad, K.; Mccubbin, I.; Miller, C. E.

    2017-12-01

    The California Baseline Methane Survey is the first systematic, statewide assessment of methane point source emissions. The objectives are to reduce uncertainty in the state's methane budget and to identify emission mitigation priorities for state and local agencies, utilities and facility owners. The project combines remote sensing of large areas with airborne imaging spectroscopy and spatially resolved bottom-up data sets to detect, quantify and attribute emissions from diverse sectors including agriculture, waste management, oil and gas production and the natural gas supply chain. Phase 1 of the project surveyed nearly 180,000 individual facilities and infrastructure components across California in 2016 - achieving completeness rates ranging from 20% to 100% per emission sector at < 5 meters spatial resolution. Additionally, intensive studies of key areas and sectors were performed to assess source persistence and variability at times scales ranging from minutes to months. Phase 2 of the project continues with additional data collection in Spring and Fall 2017. We describe the survey design and measurement, modeling and analysis methods. We present initial findings regarding the spatial, temporal and sectoral distribution of methane point source emissions in California and their estimated contribution to the state's total methane budget. We provide case-studies and lessons learned about key sectors including examples where super-emitters were identified and mitigated. We summarize challenges and recommendations for future methane research, inventories and mitigation guidance within and beyond California.

  19. Oscillation Baselining and Analysis Tool

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-27

    PNNL developed a new tool for oscillation analysis and baselining. This tool has been developed under a new DOE Grid Modernization Laboratory Consortium (GMLC) Project (GM0072 - “Suite of open-source applications and models for advanced synchrophasor analysis”) and it is based on the open platform for PMU analysis. The Oscillation Baselining and Analysis Tool (OBAT) performs the oscillation analysis and identifies modes of oscillations (frequency, damping, energy, and shape). The tool also does oscillation event baselining (fining correlation between oscillations characteristics and system operating conditions).

  20. 324 Building Baseline Radiological Characterization

    Energy Technology Data Exchange (ETDEWEB)

    R.J. Reeder, J.C. Cooper

    2010-06-24

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  1. Baseline restoration using current conveyors

    International Nuclear Information System (INIS)

    Morgado, A.M.L.S.; Simoes, J.B.; Correia, C.M.

    1996-01-01

    A good performance of high resolution nuclear spectrometry systems, at high pulse rates, demands restoration of baseline between pulses, in order to remove rate dependent baseline shifts. This restoration is performed by circuits named baseline restorers (BLRs) which also remove low frequency noise, such as power supply hum and detector microphonics. This paper presents simple circuits for baseline restoration based on a commercial current conveyor (CCII01). Tests were performed, on two circuits, with periodic trapezoidal shaped pulses in order to measure the baseline restoration for several pulse rates and restorer duty cycles. For the current conveyor based Robinson restorer, the peak shift was less than 10 mV, for duty cycles up to 60%, at high pulse rates. Duty cycles up to 80% were also tested, being the maximum peak shift 21 mV. The peak shift for the current conveyor based Grubic restorer was also measured. The maximum value found was 30 mV at 82% duty cycle. Keeping the duty cycle below 60% improves greatly the restorer performance. The ability of both baseline restorer architectures to reject low frequency modulation is also measured, with good results on both circuits

  2. Developing RESRAD-BASELINE for environmental baseline risk assessment

    International Nuclear Information System (INIS)

    Cheng, Jing-Jy.

    1995-01-01

    RESRAD-BASELINE is a computer code developed at Argonne developed at Argonne National Laboratory for the US Department of Energy (DOE) to perform both radiological and chemical risk assessments. The code implements the baseline risk assessment guidance of the US Environmental Protection Agency (EPA 1989). The computer code calculates (1) radiation doses and cancer risks from exposure to radioactive materials, and (2) hazard indexes and cancer risks from exposure to noncarcinogenic and carcinogenic chemicals, respectively. The user can enter measured or predicted environmental media concentrations from the graphic interface and can simulate different exposure scenarios by selecting the appropriate pathways and modifying the exposure parameters. The database used by PESRAD-BASELINE includes dose conversion factors and slope factors for radionuclides and toxicity information and properties for chemicals. The user can modify the database for use in the calculation. Sensitivity analysis can be performed while running the computer code to examine the influence of the input parameters. Use of RESRAD-BASELINE for risk analysis is easy, fast, and cost-saving. Furthermore, it ensures in consistency in methodology for both radiological and chemical risk analyses

  3. Long baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Gallagher, H.

    2006-01-01

    In this paper I will review briefly the experimental results which established the existence of neutrino mixing, the current generation of long baseline accelerator experiments, and the prospects for the future. In particular I will focus on the recent analysis of the MINOS experiment. (author)

  4. Baseline Report on HB2320

    Science.gov (United States)

    State Council of Higher Education for Virginia, 2015

    2015-01-01

    Staff provides this baseline report as a summary of its preliminary considerations and initial research in fulfillment of the requirements of HB2320 from the 2015 session of the General Assembly. Codified as § 23-7.4:7, this legislation compels the Education Secretary and the State Council of Higher Education for Virginia (SCHEV) Director, in…

  5. Integrated Baseline Review (IBR) Handbook

    Science.gov (United States)

    Fleming, Jon F.; Terrell, Stefanie M.

    2018-01-01

    The purpose of this handbook is intended to be a how-to guide to prepare for, conduct, and close-out an Integrated Baseline Review (IBR). It discusses the steps that should be considered, describes roles and responsibilities, tips for tailoring the IBR based on risk, cost, and need for management insight, and provides lessons learned from past IBRs. Appendices contain example documentation typically used in connection with an IBR. Note that these appendices are examples only, and should be tailored to meet the needs of individual projects and contracts.

  6. Environmental Baseline File National Transportation

    International Nuclear Information System (INIS)

    Harris, M.

    1999-01-01

    This Environmental Baseline File summarizes and consolidates information related to the national-level transportation of commercial spent nuclear fuel. Topics addressed include: shipments of commercial spent nuclear fuel based on mostly truck and mostly rail shipping scenarios; transportation routing for commercial spent nuclear fuel sites and DOE sites; radionuclide inventories for various shipping container capacities; transportation routing; populations along transportation routes; urbanized area population densities; the impacts of historical, reasonably foreseeable, and general transportation; state-level food transfer factors; Federal Guidance Report No. 11 and 12 radionuclide dose conversion factors; and national average atmospheric conditions

  7. Baseline atmospheric program Australia 1993

    International Nuclear Information System (INIS)

    Francey, R.J.; Dick, A.L.; Derek, N.

    1996-01-01

    This publication reports activities, program summaries and data from the Cape Grim Baseline Air Pollution Station in Tasmania, during the calendar year 1993. These activities represent Australia's main contribution to the Background Air Pollution Monitoring Network (BAPMoN), part of the World Meteorological Organization's Global Atmosphere Watch (GAW). The report includes 5 research reports covering trace gas sampling, ozone and radon interdependence, analysis of atmospheric dimethylsulfide and carbon-disulfide, sampling of trace gas composition of the troposphere, and sulfur aerosol/CCN relationship in marine air. Summaries of program reports for the calendar year 1993 are also included. Tabs., figs., refs

  8. Baseline LAW Glass Formulation Testing

    International Nuclear Information System (INIS)

    Kruger, Albert A.; Mooers, Cavin; Bazemore, Gina; Pegg, Ian L.; Hight, Kenneth; Lai, Shan Tao; Buechele, Andrew; Rielley, Elizabeth; Gan, Hao; Muller, Isabelle S.; Cecil, Richard

    2013-01-01

    The major objective of the baseline glass formulation work was to develop and select glass formulations that are compliant with contractual and processing requirements for each of the LAW waste streams. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, development of glass formulations to support ILAW qualification activities, and identification of glass formulation issues with respect to contract specifications and processing requirements

  9. FED baseline engineering studies report

    Energy Technology Data Exchange (ETDEWEB)

    Sager, P.H.

    1983-04-01

    Studies were carried out on the FED Baseline to improve design definition, establish feasibility, and reduce cost. Emphasis was placed on cost reduction, but significant feasibility concerns existed in several areas, and better design definition was required to establish feasibility and provide a better basis for cost estimates. Design definition and feasibility studies included the development of a labyrinth shield ring concept to prevent radiation streaming between the torus spool and the TF coil cryostat. The labyrinth shield concept which was developed reduced radiation streaming sufficiently to permit contact maintenance of the inboard EF coils. Various concepts of preventing arcing between adjacent shield sectors were also explored. It was concluded that installation of copper straps with molybdenum thermal radiation shields would provide the most reliable means of preventing arcing. Other design studies included torus spool electrical/structural concepts, test module shielding, torus seismic response, poloidal conditions in the magnets, disruption characteristics, and eddy current effects. These additional studies had no significant impact on cost but did confirm the feasibility of the basic FED Baseline concept.

  10. FED baseline engineering studies report

    International Nuclear Information System (INIS)

    Sager, P.H.

    1983-04-01

    Studies were carried out on the FED Baseline to improve design definition, establish feasibility, and reduce cost. Emphasis was placed on cost reduction, but significant feasibility concerns existed in several areas, and better design definition was required to establish feasibility and provide a better basis for cost estimates. Design definition and feasibility studies included the development of a labyrinth shield ring concept to prevent radiation streaming between the torus spool and the TF coil cryostat. The labyrinth shield concept which was developed reduced radiation streaming sufficiently to permit contact maintenance of the inboard EF coils. Various concepts of preventing arcing between adjacent shield sectors were also explored. It was concluded that installation of copper straps with molybdenum thermal radiation shields would provide the most reliable means of preventing arcing. Other design studies included torus spool electrical/structural concepts, test module shielding, torus seismic response, poloidal conditions in the magnets, disruption characteristics, and eddy current effects. These additional studies had no significant impact on cost but did confirm the feasibility of the basic FED Baseline concept

  11. Pinellas Plant Environmental Baseline Report

    Energy Technology Data Exchange (ETDEWEB)

    1997-06-01

    The Pinellas Plant has been part of the Department of Energy`s (DOE) nuclear weapons complex since the plant opened in 1957. In March 1995, the DOE sold the Pinellas Plant to the Pinellas County Industry Council (PCIC). DOE has leased back a large portion of the plant site to facilitate transition to alternate use and safe shutdown. The current mission is to achieve a safe transition of the facility from defense production and prepare the site for alternative uses as a community resource for economic development. Toward that effort, the Pinellas Plant Environmental Baseline Report (EBR) discusses the current and past environmental conditions of the plant site. Information for the EBR is obtained from plant records. Historical process and chemical usage information for each area is reviewed during area characterizations.

  12. Integrated Baseline Review (IBR) Handbook

    Science.gov (United States)

    Fleming, Jon F.; Kehrer, Kristen C.

    2016-01-01

    The purpose of this handbook is intended to be a how-to guide to prepare for, conduct, and close-out an Integrated Baseline Review (IBR). It discusses the steps that should be considered, describes roles and responsibilities, tips for tailoring the IBR based on risk, cost, and need for management insight, and provides lessons learned from past IBRs. Appendices contain example documentation typically used in connection with an IBR. Note that these appendices are examples only, and should be tailored to meet the needs of individual projects and contracts. Following the guidance in this handbook will help customers and suppliers preparing for an IBR understand the expectations of the IBR, and ensure that the IBR meets the requirements for both in-house and contract efforts.

  13. Baseline Estimation and Outlier Identification for Halocarbons

    Science.gov (United States)

    Wang, D.; Schuck, T.; Engel, A.; Gallman, F.

    2017-12-01

    The aim of this paper is to build a baseline model for halocarbons and to statistically identify the outliers under specific conditions. In this paper, time series of regional CFC-11 and Chloromethane measurements was discussed, which taken over the last 4 years at two locations, including a monitoring station at northwest of Frankfurt am Main (Germany) and Mace Head station (Ireland). In addition to analyzing time series of CFC-11 and Chloromethane, more importantly, a statistical approach of outlier identification is also introduced in this paper in order to make a better estimation of baseline. A second-order polynomial plus harmonics are fitted to CFC-11 and chloromethane mixing ratios data. Measurements with large distance to the fitting curve are regard as outliers and flagged. Under specific requirement, the routine is iteratively adopted without the flagged measurements until no additional outliers are found. Both model fitting and the proposed outlier identification method are realized with the help of a programming language, Python. During the period, CFC-11 shows a gradual downward trend. And there is a slightly upward trend in the mixing ratios of Chloromethane. The concentration of chloromethane also has a strong seasonal variation, mostly due to the seasonal cycle of OH. The usage of this statistical method has a considerable effect on the results. This method efficiently identifies a series of outliers according to the standard deviation requirements. After removing the outliers, the fitting curves and trend estimates are more reliable.

  14. High Baseline Postconcussion Symptom Scores and Concussion Outcomes in Athletes.

    Science.gov (United States)

    Custer, Aimee; Sufrinko, Alicia; Elbin, R J; Covassin, Tracey; Collins, Micky; Kontos, Anthony

    2016-02-01

    Some healthy athletes report high levels of baseline concussion symptoms, which may be attributable to several factors (eg, illness, personality, somaticizing). However, the role of baseline symptoms in outcomes after sport-related concussion (SRC) has not been empirically examined. To determine if athletes with high symptom scores at baseline performed worse than athletes without baseline symptoms on neurocognitive testing after SRC. Cohort study. High school and collegiate athletic programs. A total of 670 high school and collegiate athletes participated in the study. Participants were divided into groups with either no baseline symptoms (Postconcussion Symptom Scale [PCSS] score = 0, n = 247) or a high level of baseline symptoms (PCSS score > 18 [top 10% of sample], n = 68). Participants were evaluated at baseline and 2 to 7 days after SRC with the Immediate Post-concussion Assessment and Cognitive Test and PCSS. Outcome measures were Immediate Post-concussion Assessment and Cognitive Test composite scores (verbal memory, visual memory, visual motor processing speed, and reaction time) and total symptom score on the PCSS. The groups were compared using repeated-measures analyses of variance with Bonferroni correction to assess interactions between group and time for symptoms and neurocognitive impairment. The no-symptoms group represented 38% of the original sample, whereas the high-symptoms group represented 11% of the sample. The high-symptoms group experienced a larger decline from preinjury to postinjury than the no-symptoms group in verbal (P = .03) and visual memory (P = .05). However, total concussion-symptom scores increased from preinjury to postinjury for the no-symptoms group (P = .001) but remained stable for the high-symptoms group. Reported baseline symptoms may help identify athletes at risk for worse outcomes after SRC. Clinicians should examine baseline symptom levels to better identify patients for earlier referral and treatment for their

  15. Hydrogeology baseline study Aurora Mine

    International Nuclear Information System (INIS)

    1996-01-01

    A baseline hydrogeologic study was conducted in the area of Syncrude's proposed Aurora Mine in order to develop a conceptual regional hydrogeologic model for the area that could be used to understand groundwater flow conditions. Geologic information was obtained from over 2,000 coreholes and from data obtained between 1980 and 1996 regarding water level for the basal aquifer. A 3-D numerical groundwater flow model was developed to provide quantitative estimates of the potential environmental impacts of the proposed mining operations on the groundwater flow system. The information was presented in the context of a regional study area which encompassed much of the Athabasca Oil Sands Region, and a local study area which was defined by the lowlands of the Muskeg River Basin. Characteristics of the topography, hydrology, climate, geology, and hydrogeology of the region are described. The conclusion is that groundwater flow in the aquifer occurs mostly in a westerly direction beneath the Aurora Mine towards its inferred discharge location along the Athabasca River. Baseflow in the Muskeg River is mostly related to discharge from shallow surficial aquifers. Water in the river under baseflow conditions was fresh, of calcium-carbonate type, with very little indication of mineralization associated with deeper groundwater in the Aurora Mine area. 44 refs., 5 tabs., 31 figs

  16. 2016 Annual Technology Baseline (ATB)

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley; Kurup, Parthiv; Hand, Maureen; Feldman, David; Sigrin, Benjamin; Lantz, Eric; Stehly, Tyler; Augustine, Chad; Turchi, Craig; O' Connor, Patrick; Waldoch, Connor

    2016-09-01

    Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), National Renewable Energy Laboratory provides an organized and centralized dataset that was reviewed by internal and external experts. It uses the best information from the Department of Energy laboratory's renewable energy analysts and Energy Information Administration information for conventional technologies. The ATB will be updated annually in order to provide an up-to-date repository of current and future cost and performance data. Going forward, we plan to revise and refine the values using best available information. The ATB includes both a presentation with notes (PDF) and an associated Excel Workbook. The ATB includes the following electricity generation technologies: land-based wind; offshore wind; utility-scale solar PV; concentrating solar power; geothermal power; hydropower plants (upgrades to existing facilities, powering non-powered dams, and new stream-reach development); conventional coal; coal with carbon capture and sequestration; integrated gasification combined cycle coal; natural gas combustion turbines; natural gas combined cycle; conventional biopower. Nuclear laboratory's renewable energy analysts and Energy Information Administration information for conventional technologies. The ATB will be updated annually in order to provide an up-to-date repository of current and future cost and performance data. Going forward, we plan to revise and refine the values using best available information.

  17. 2016 Annual Technology Baseline (ATB) - Webinar Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley; Kurup, Parthiv; Hand, Maureen; Feldman, David; Sigrin, Benjamin; Lantz, Eric; Stehly, Tyler; Augustine, Chad; Turchi, Craig; Porro, Gian; O' Connor, Patrick; Waldoch, Connor

    2016-09-13

    This deck was presented for the 2016 Annual Technology Baseline Webinar. The presentation describes the Annual Technology Baseline, which is a compilation of current and future cost and performance data for electricity generation technologies.

  18. 75 FR 66748 - Notice of Baseline Filings

    Science.gov (United States)

    2010-10-29

    ...- 000] Notice of Baseline Filings October 22, 2010. ONEOK Gas Transportation, L.L.C Docket No. PR11-68... above submitted a revised baseline filing of their Statement of Operating Conditions for services...

  19. Dynamic baseline detection method for power data network service

    Science.gov (United States)

    Chen, Wei

    2017-08-01

    This paper proposes a dynamic baseline Traffic detection Method which is based on the historical traffic data for the Power data network. The method uses Cisco's NetFlow acquisition tool to collect the original historical traffic data from network element at fixed intervals. This method uses three dimensions information including the communication port, time, traffic (number of bytes or number of packets) t. By filtering, removing the deviation value, calculating the dynamic baseline value, comparing the actual value with the baseline value, the method can detect whether the current network traffic is abnormal.

  20. 324 Building Baseline Radiological Characterization

    International Nuclear Information System (INIS)

    Reeder, R.J.; Cooper, J.C.

    2010-01-01

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building. A total of 85 technical (100 square centimeter (cm 2 )) smears were collected from the Room 147 hoods, the Shielded Materials Facility (SMF), and the Radiochemical Engineering Cells (REC). Exposure rate readings (window open and window closed) were taken at a distance of 2.5 centimeters (cm) and 30 cm from the surface of each smear. Gross beta-gamma and alpha counts of each smear were also performed. The smear samples were analyzed by gamma energy analysis (GEA). Alpha energy analysis (AEA) and strontium-90 analysis were also performed on selected smears. GEA results for one or more samples reported the presence of manganese-54, cobalt-60, silver-108m antimony-125, cesium-134, cesium-137, europium-154, europium-155, and americium-241. AEA results reported the presence of plutonium-239/240, plutonium-238/ 241 Am, curium-243/244, curium-242, and americium-243. Tables 5 through 9 present a summary by location of the estimated maximum removable and total contamination levels in the Room 147 hoods, the SMF, and the REC. The smear sample survey data and laboratory analytical results are presented in tabular form by sample in Appendix A. The Appendix A tables combine survey data documented in radiological survey reports found in Appendix B and laboratory analytical results reported in the 324 Building Physical and Radiological Characterization Study (Berk, Hill, and Landsman 1998), supplemented by the laboratory analytical results found in Appendix C.

  1. Program Baseline Change Control Board charter

    International Nuclear Information System (INIS)

    1993-02-01

    The purpose of this Charter is to establish the Program Baseline Change Control Board (PBCCB) for the Office of Civilian Radioactive Waste Management (OCRWM) Program, and to describe its organization, responsibilities, and basic methods of operation. Guidance for implementing this Charter is provided by the OCRWM Baseline Management Plan (BMP) and OCRWM Program Baseline Change Control Procedure

  2. 40 CFR 1042.825 - Baseline determination.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Baseline determination. 1042.825... Provisions for Remanufactured Marine Engines § 1042.825 Baseline determination. (a) For the purpose of this... not valid. (f) Use good engineering judgment for all aspects of the baseline determination. We may...

  3. Structure of a traditional baseline data system

    Energy Technology Data Exchange (ETDEWEB)

    1976-12-01

    Research was conducted to determine whether appropriate data exist for the development of a comprehensive statistical baseline data system on the human environment in the Athabasca oil sands region of Alberta. The existing data sources pertinent to the target area were first reviewed and discussed. Criteria were selected to assist the evaluation of data, including type of data collected, source, degree of detail, geographic identification, accessibility, and time frame. These criteria allowed assessing whether the data would be amenable to geographically-coded, continuous monitoring systems. It was found that the Statistics Canada Census provided the most detail, the most complete coverage of the target area, the smallest statistical areas, the greatest consistency in data and data collection, and the most regular collection. The local agency collection efforts were generally oriented toward specific goals and the data intended primarily for intra-agency use. The smallest statistical units in these efforts may be too large to be of value to a common small-area system, and data collection agencies did not generally use coterminous boundaries. Recommendations were made to give primary consideration to Statistics Canada data in the initial development of the baseline data system. Further development of such a system depends on the adoption by local agencies of a common small-area system for data collection. 38 refs., 6 figs.

  4. Extracting Baseline Electricity Usage Using Gradient Tree Boosting

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Taehoon [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Lee, Dongeun [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Choi, Jaesik [Ulsan Nat. Inst. of Sci. & Tech., Ulsan (South Korea); Spurlock, Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sim, Alex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wu, Kesheng [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-05

    To understand how specific interventions affect a process observed over time, we need to control for the other factors that influence outcomes. Such a model that captures all factors other than the one of interest is generally known as a baseline. In our study of how different pricing schemes affect residential electricity consumption, the baseline would need to capture the impact of outdoor temperature along with many other factors. In this work, we examine a number of different data mining techniques and demonstrate Gradient Tree Boosting (GTB) to be an effective method to build the baseline. We train GTB on data prior to the introduction of new pricing schemes, and apply the known temperature following the introduction of new pricing schemes to predict electricity usage with the expected temperature correction. Our experiments and analyses show that the baseline models generated by GTB capture the core characteristics over the two years with the new pricing schemes. In contrast to the majority of regression based techniques which fail to capture the lag between the peak of daily temperature and the peak of electricity usage, the GTB generated baselines are able to correctly capture the delay between the temperature peak and the electricity peak. Furthermore, subtracting this temperature-adjusted baseline from the observed electricity usage, we find that the resulting values are more amenable to interpretation, which demonstrates that the temperature-adjusted baseline is indeed effective.

  5. In-Space Manufacturing Baseline Property Development

    Science.gov (United States)

    Stockman, Tom; Schneider, Judith; Prater, Tracie; Bean, Quincy; Werkheiser, Nicki

    2016-01-01

    The In-Space Manufacturing (ISM) project at NASA Marshall Space Flight Center currently operates a 3D FDM (fused deposition modeling) printer onboard the International Space Station. In order to enable utilization of this capability by designer, the project needs to establish characteristic material properties for materials produced using the process. This is difficult for additive manufacturing since standards and specifications do not yet exist for these technologies. Due to availability of crew time, there are limitations to the sample size which in turn limits the application of the traditional design allowables approaches to develop a materials property database for designers. In this study, various approaches to development of material databases were evaluated for use by designers of space systems who wish to leverage in-space manufacturing capabilities. This study focuses on alternative statistical techniques for baseline property development to support in-space manufacturing.

  6. Overseas Environmental Baseline Guidance Document

    Science.gov (United States)

    2007-05-01

    milligrams per liter (mg/L) determined before or at the first customer, and the corresponding disinfectant contact time, T , in minutes. CT values...for a CWS and NTNCWS that adds a disinfectant (oxidant, such as chlorine, chlorine dioxide, chloramines , or ozone) to any part of its treatment...drinking water. Operators may increase residual disinfectant levels of chlorine or chloramines (but not chlorine dioxide) in the distribution system to a

  7. 40 CFR 74.20 - Data for baseline and alternative baseline.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Data for baseline and alternative baseline. 74.20 Section 74.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... baseline and alternative baseline. (a) Acceptable data. (1) The designated representative of a combustion...

  8. Hazard Baseline Downgrade Effluent Treatment Facility

    International Nuclear Information System (INIS)

    Blanchard, A.

    1998-01-01

    This Hazard Baseline Downgrade reviews the Effluent Treatment Facility, in accordance with Department of Energy Order 5480.23, WSRC11Q Facility Safety Document Manual, DOE-STD-1027-92, and DOE-EM-STD-5502-94. It provides a baseline grouping based on the chemical and radiological hazards associated with the facility. The Determination of the baseline grouping for ETF will aid in establishing the appropriate set of standards for the facility

  9. IPCC Socio-Economic Baseline Dataset

    Data.gov (United States)

    National Aeronautics and Space Administration — The Intergovernmental Panel on Climate Change (IPCC) Socio-Economic Baseline Dataset consists of population, human development, economic, water resources, land...

  10. Addendum to the 2015 Eastern Interconnect Baselining and Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Follum, James D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    This report serves as an addendum to the report 2015 Eastern Interconnect Baselining and Analysis Report (Amidan, Follum, and Freeman, 2015). This addendum report investigates the following: the impact of shorter record lengths and of adding a daily regularization term to the date/time models for angle pair measurements, additional development of a method to monitor the trend in phase angle pairs, the effect of changing the length of time to determine a baseline, when calculating atypical events, and a comparison between quantitatively discovered atypical events and actual events.

  11. TAPIR--Finnish national geochemical baseline database.

    Science.gov (United States)

    Jarva, Jaana; Tarvainen, Timo; Reinikainen, Jussi; Eklund, Mikael

    2010-09-15

    In Finland, a Government Decree on the Assessment of Soil Contamination and Remediation Needs has generated a need for reliable and readily accessible data on geochemical baseline concentrations in Finnish soils. According to the Decree, baseline concentrations, referring both to the natural geological background concentrations and the diffuse anthropogenic input of substances, shall be taken into account in the soil contamination assessment process. This baseline information is provided in a national geochemical baseline database, TAPIR, that is publicly available via the Internet. Geochemical provinces with elevated baseline concentrations were delineated to provide regional geochemical baseline values. The nationwide geochemical datasets were used to divide Finland into geochemical provinces. Several metals (Co, Cr, Cu, Ni, V, and Zn) showed anomalous concentrations in seven regions that were defined as metal provinces. Arsenic did not follow a similar distribution to any other elements, and four arsenic provinces were separately determined. Nationwide geochemical datasets were not available for some other important elements such as Cd and Pb. Although these elements are included in the TAPIR system, their distribution does not necessarily follow the ones pre-defined for metal and arsenic provinces. Regional geochemical baseline values, presented as upper limit of geochemical variation within the region, can be used as trigger values to assess potential soil contamination. Baseline values have also been used to determine upper and lower guideline values that must be taken into account as a tool in basic risk assessment. If regional geochemical baseline values are available, the national guideline values prescribed in the Decree based on ecological risks can be modified accordingly. The national geochemical baseline database provides scientifically sound, easily accessible and generally accepted information on the baseline values, and it can be used in various

  12. STATUS OF THE US LONG BASELINE NEUTRINO EXPERIMENT STUDY.

    Energy Technology Data Exchange (ETDEWEB)

    BISHAI,M.

    2006-09-21

    The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory and Fermi National Accelerator Laboratory to investigate the potential for future U.S. based long baseline neutrino oscillation experiments beyond the currently planned program. The Study focused on MW class convention at neutrino beams that can be produced at Fermilab or BNL. The experimental baselines are based on two possible detector locations: (1) off-axis to the existing Fermilab NuMI beamline at baselines of 700 to 810 km and (2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000 km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from Fermilab or BNL aimed at a massive detector with a baseline of > 1000 km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2.2{sup o}.

  13. MALDI-TOF Baseline Drift Removal Using Stochastic Bernstein Approximation

    Directory of Open Access Journals (Sweden)

    Howard Daniel

    2006-01-01

    Full Text Available Stochastic Bernstein (SB approximation can tackle the problem of baseline drift correction of instrumentation data. This is demonstrated for spectral data: matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF data. Two SB schemes for removing the baseline drift are presented: iterative and direct. Following an explanation of the origin of the MALDI-TOF baseline drift that sheds light on the inherent difficulty of its removal by chemical means, SB baseline drift removal is illustrated for both proteomics and genomics MALDI-TOF data sets. SB is an elegant signal processing method to obtain a numerically straightforward baseline shift removal method as it includes a free parameter that can be optimized for different baseline drift removal applications. Therefore, research that determines putative biomarkers from the spectral data might benefit from a sensitivity analysis to the underlying spectral measurement that is made possible by varying the SB free parameter. This can be manually tuned (for constant or tuned with evolutionary computation (for .

  14. Safe and sensible preprocessing and baseline correction of pupil-size data.

    Science.gov (United States)

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-02-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

  15. FAQs about Baseline Testing among Young Athletes

    Science.gov (United States)

    ... a similar exam conducted by a health care professional during the season if an athlete has a suspected concussion. Baseline testing generally takes place during the pre-season—ideally prior to the first practice. It is important to note that some baseline ...

  16. 75 FR 74706 - Notice of Baseline Filings

    Science.gov (United States)

    2010-12-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Baseline Filings November 24, 2010. Centana Intrastate Pipeline, LLC. Docket No. PR10-84-001. Centana Intrastate Pipeline, LLC... applicants listed above submitted a revised baseline filing of their Statement of Operating Conditions for...

  17. 76 FR 8725 - Notice of Baseline Filings

    Science.gov (United States)

    2011-02-15

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Baseline Filings Enstor Grama Ridge Storage and Docket No. PR10-97-002. Transportation, L.L.C.. EasTrans, LLC Docket No. PR10-30-001... revised baseline filing of their Statement of Operating Conditions for services provided under section 311...

  18. 75 FR 57268 - Notice of Baseline Filings

    Science.gov (United States)

    2010-09-20

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-103-000; Docket No. PR10-104-000; Docket No. PR10-105- 000 (Not Consolidated)] Notice of Baseline Filings September 13..., 2010, and September 10, 2010, respectively the applicants listed above submitted their baseline filing...

  19. 75 FR 65010 - Notice of Baseline Filings

    Science.gov (United States)

    2010-10-21

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-1-000; Docket No. PR11-2-000; Docket No. PR11-3-000] Notice of Baseline Filings October 14, 2010. Cranberry Pipeline Docket..., 2010, respectively the applicants listed above submitted their baseline filing of its Statement of...

  20. 76 FR 5797 - Notice of Baseline Filings

    Science.gov (United States)

    2011-02-02

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-114-001; Docket No. PR10-129-001; Docket No. PR10-131- 001; Docket No. PR10-68-002 Not Consolidated] Notice of Baseline... applicants listed above submitted a revised baseline filing of their Statement of Operating Conditions for...

  1. 75 FR 70732 - Notice of Baseline Filings

    Science.gov (United States)

    2010-11-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-71-000; Docket No. PR11-72-000; Docket No. PR11-73- 000] Notice of Baseline Filings November 10, 2010. Docket No. PR11-71-000..., 2010, the applicants listed above submitted their baseline filing of their Statement of Operating...

  2. Baseline Architecture of ITER Control System

    Science.gov (United States)

    Wallander, A.; Di Maio, F.; Journeaux, J.-Y.; Klotz, W.-D.; Makijarvi, P.; Yonekawa, I.

    2011-08-01

    The control system of ITER consists of thousands of computers processing hundreds of thousands of signals. The control system, being the primary tool for operating the machine, shall integrate, control and coordinate all these computers and signals and allow a limited number of staff to operate the machine from a central location with minimum human intervention. The primary functions of the ITER control system are plant control, supervision and coordination, both during experimental pulses and 24/7 continuous operation. The former can be split in three phases; preparation of the experiment by defining all parameters; executing the experiment including distributed feed-back control and finally collecting, archiving, analyzing and presenting all data produced by the experiment. We define the control system as a set of hardware and software components with well defined characteristics. The architecture addresses the organization of these components and their relationship to each other. We distinguish between physical and functional architecture, where the former defines the physical connections and the latter the data flow between components. In this paper, we identify the ITER control system based on the plant breakdown structure. Then, the control system is partitioned into a workable set of bounded subsystems. This partition considers at the same time the completeness and the integration of the subsystems. The components making up subsystems are identified and defined, a naming convention is introduced and the physical networks defined. Special attention is given to timing and real-time communication for distributed control. Finally we discuss baseline technologies for implementing the proposed architecture based on analysis, market surveys, prototyping and benchmarking carried out during the last year.

  3. Cryogenics Testbed Laboratory Flange Baseline Configuration

    Science.gov (United States)

    Acuna, Marie Lei Ysabel D.

    2013-01-01

    As an intern at Kennedy Space Center (KSC), I was involved in research for the Fluids and Propulsion Division of the NASA Engineering (NE) Directorate. I was immersed in the Integrated Ground Operations Demonstration Units (IGODU) project for the majority of my time at KSC, primarily with the Ground Operations Demonstration Unit Liquid Oxygen (GODU L02) branch of IGODU. This project was established to develop advancements in cryogenic systems as a part of KSC's Advanced Exploration Systems (AES) program. The vision of AES is to develop new approaches for human exploration, and operations in and beyond low Earth orbit. Advanced cryogenic systems are crucial to minimize the consumable losses of cryogenic propellants, develop higher performance launch vehicles, and decrease operations cost for future launch programs. During my internship, I conducted a flange torque tracking study that established a baseline configuration for the flanges in the Simulated Propellant Loading System (SPLS) at the KSC Cryogenics Test Laboratory (CTL) - the testing environment for GODU L02.

  4. Gated integrator with signal baseline subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.

    1996-12-17

    An ultrafast, high precision gated integrator includes an opamp having differential inputs. A signal to be integrated is applied to one of the differential inputs through a first input network, and a signal indicative of the DC offset component of the signal to be integrated is applied to the other of the differential inputs through a second input network. A pair of electronic switches in the first and second input networks define an integrating period when they are closed. The first and second input networks are substantially symmetrically constructed of matched components so that error components introduced by the electronic switches appear symmetrically in both input circuits and, hence, are nullified by the common mode rejection of the integrating opamp. The signal indicative of the DC offset component is provided by a sample and hold circuit actuated as the integrating period begins. The symmetrical configuration of the integrating circuit improves accuracy and speed by balancing out common mode errors, by permitting the use of high speed switching elements and high speed opamps and by permitting the use of a small integrating time constant. The sample and hold circuit substantially eliminates the error caused by the input signal baseline offset during a single integrating window. 5 figs.

  5. Gated integrator with signal baseline subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xucheng (Lisle, IL)

    1996-01-01

    An ultrafast, high precision gated integrator includes an opamp having differential inputs. A signal to be integrated is applied to one of the differential inputs through a first input network, and a signal indicative of the DC offset component of the signal to be integrated is applied to the other of the differential inputs through a second input network. A pair of electronic switches in the first and second input networks define an integrating period when they are closed. The first and second input networks are substantially symmetrically constructed of matched components so that error components introduced by the electronic switches appear symmetrically in both input circuits and, hence, are nullified by the common mode rejection of the integrating opamp. The signal indicative of the DC offset component is provided by a sample and hold circuit actuated as the integrating period begins. The symmetrical configuration of the integrating circuit improves accuracy and speed by balancing out common mode errors, by permitting the use of high speed switching elements and high speed opamps and by permitting the use of a small integrating time constant. The sample and hold circuit substantially eliminates the error caused by the input signal baseline offset during a single integrating window.

  6. TWRS technical baseline database manager definition document

    International Nuclear Information System (INIS)

    Acree, C.D.

    1997-01-01

    This document serves as a guide for using the TWRS Technical Baseline Database Management Systems Engineering (SE) support tool in performing SE activities for the Tank Waste Remediation System (TWRS). This document will provide a consistent interpretation of the relationships between the TWRS Technical Baseline Database Management software and the present TWRS SE practices. The Database Manager currently utilized is the RDD-1000 System manufactured by the Ascent Logic Corporation. In other documents, the term RDD-1000 may be used interchangeably with TWRS Technical Baseline Database Manager

  7. Life Support Baseline Values and Assumptions Document

    Science.gov (United States)

    Anderson, Molly S.; Ewert, Michael K.; Keener, John F.

    2018-01-01

    The Baseline Values and Assumptions Document (BVAD) provides analysts, modelers, and other life support researchers with a common set of values and assumptions which can be used as a baseline in their studies. This baseline, in turn, provides a common point of origin from which many studies in the community may depart, making research results easier to compare and providing researchers with reasonable values to assume for areas outside their experience. This document identifies many specific physical quantities that define life support systems, serving as a general reference for spacecraft life support system technology developers.

  8. Placental baseline conditions modulate the hyperoxic BOLD-MRI response.

    Science.gov (United States)

    Sinding, Marianne; Peters, David A; Poulsen, Sofie S; Frøkjær, Jens B; Christiansen, Ole B; Petersen, Astrid; Uldbjerg, Niels; Sørensen, Anne

    2018-01-01

    Human pregnancies complicated by placental dysfunction may be characterized by a high hyperoxic Blood oxygen level-dependent (BOLD) MRI response. The pathophysiology behind this phenomenon remains to be established. The aim of this study was to evaluate whether it is associated with altered placental baseline conditions, including a lower oxygenation and altered tissue morphology, as estimated by the placental transverse relaxation time (T2*). We included 49 normal pregnancies (controls) and 13 pregnancies complicated by placental dysfunction (cases), defined by a birth weight baseline BOLD)/baseline BOLD) from a dynamic single-echo gradient-recalled echo (GRE) MRI sequence and the absolute ΔT2* (hyperoxic T2*- baseline T2*) from breath-hold multi-echo GRE sequences. In the control group, the relative ΔBOLD response increased during gestation from 5% in gestational week 20 to 20% in week 40. In the case group, the relative ΔBOLD response was significantly higher (mean Z-score 4.94; 95% CI 2.41, 7.47). The absolute ΔT2*, however, did not differ between controls and cases (p = 0.37), whereas the baseline T2* was lower among cases (mean Z-score -3.13; 95% CI -3.94, -2.32). Furthermore, we demonstrated a strong negative linear correlation between the Log 10 ΔBOLD response and the baseline T2* (r = -0.88, p baseline conditions, as the absolute increase in placental oxygenation (ΔT2*) does not differ between groups. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Hanford Site technical baseline database. Revision 1

    International Nuclear Information System (INIS)

    Porter, P.E.

    1995-01-01

    This report lists the Hanford specific files (Table 1) that make up the Hanford Site Technical Baseline Database. Table 2 includes the delta files that delineate the differences between this revision and revision 0 of the Hanford Site Technical Baseline Database. This information is being managed and maintained on the Hanford RDD-100 System, which uses the capabilities of RDD-100, a systems engineering software system of Ascent Logic Corporation (ALC). This revision of the Hanford Site Technical Baseline Database uses RDD-100 version 3.0.2.2 (see Table 3). Directories reflect those controlled by the Hanford RDD-100 System Administrator. Table 4 provides information regarding the platform. A cassette tape containing the Hanford Site Technical Baseline Database is available

  10. Atmospheric pressure loading parameters from very long baseline interferometry observations

    Science.gov (United States)

    Macmillan, D. S.; Gipson, John M.

    1994-01-01

    Atmospheric mass loading produces a primarily vertical displacement of the Earth's crust. This displacement is correlated with surface pressure and is large enough to be detected by very long baseline interferometry (VLBI) measurements. Using the measured surface pressure at VLBI stations, we have estimated the atmospheric loading term for each station location directly from VLBI data acquired from 1979 to 1992. Our estimates of the vertical sensitivity to change in pressure range from 0 to -0.6 mm/mbar depending on the station. These estimates agree with inverted barometer model calculations (Manabe et al., 1991; vanDam and Herring, 1994) of the vertical displacement sensitivity computed by convolving actual pressure distributions with loading Green's functions. The pressure sensitivity tends to be smaller for stations near the coast, which is consistent with the inverted barometer hypothesis. Applying this estimated pressure loading correction in standard VLBI geodetic analysis improves the repeatability of estimated lengths of 25 out of 37 baselines that were measured at least 50 times. In a root-sum-square (rss) sense, the improvement generally increases with baseline length at a rate of about 0.3 to 0.6 ppb depending on whether the baseline stations are close to the coast. For the 5998-km baseline from Westford, Massachusetts, to Wettzell, Germany, the rss improvement is about 3.6 mm out of 11.0 mm. The average rss reduction of the vertical scatter for inland stations ranges from 2.7 to 5.4 mm.

  11. Camera Trajectory fromWide Baseline Images

    Science.gov (United States)

    Havlena, M.; Torii, A.; Pajdla, T.

    2008-09-01

    angle θ of its corresponding rays w.r.t. the optical axis as θ = ar 1+br2 . After a successful calibration, we know the correspondence of the image points to the 3D optical rays in the coordinate system of the camera. The following steps aim at finding the transformation between the camera and the world coordinate systems, i.e. the pose of the camera in the 3D world, using 2D image matches. For computing 3D structure, we construct a set of tentative matches detecting different affine covariant feature regions including MSER, Harris Affine, and Hessian Affine in acquired images. These features are alternative to popular SIFT features and work comparably in our situation. Parameters of the detectors are chosen to limit the number of regions to 1-2 thousands per image. The detected regions are assigned local affine frames (LAF) and transformed into standard positions w.r.t. their LAFs. Discrete Cosine Descriptors are computed for each region in the standard position. Finally, mutual distances of all regions in one image and all regions in the other image are computed as the Euclidean distances of their descriptors and tentative matches are constructed by selecting the mutually closest pairs. Opposed to the methods using short baseline images, simpler image features which are not affine covariant cannot be used because the view point can change a lot between consecutive frames. Furthermore, feature matching has to be performed on the whole frame because no assumptions on the proximity of the consecutive projections can be made for wide baseline images. This is making the feature detection, description, and matching much more time-consuming than it is for short baseline images and limits the usage to low frame rate sequences when operating in real-time. Robust 3D structure can be computed by RANSAC which searches for the largest subset of the set of tentative matches which is, within a predefined threshold ", consistent with an epipolar geometry. We use ordered sampling as

  12. The London low emission zone baseline study.

    Science.gov (United States)

    Kelly, Frank; Armstrong, Ben; Atkinson, Richard; Anderson, H Ross; Barratt, Ben; Beevers, Sean; Cook, Derek; Green, Dave; Derwent, Dick; Mudway, Ian; Wilkinson, Paul

    2011-11-01

    On February 4, 2008, the world's largest low emission zone (LEZ) was established. At 2644 km2, the zone encompasses most of Greater London. It restricts the entry of the oldest and most polluting diesel vehicles, including heavy-goods vehicles (haulage trucks), buses and coaches, larger vans, and minibuses. It does not apply to cars or motorcycles. The LEZ scheme will introduce increasingly stringent Euro emissions standards over time. The creation of this zone presented a unique opportunity to estimate the effects of a stepwise reduction in vehicle emissions on air quality and health. Before undertaking such an investigation, robust baseline data were gathered on air quality and the oxidative activity and metal content of particulate matter (PM) from air pollution monitors located in Greater London. In addition, methods were developed for using databases of electronic primary-care records in order to evaluate the zone's health effects. Our study began in 2007, using information about the planned restrictions in an agreed-upon LEZ scenario and year-on-year changes in the vehicle fleet in models to predict air pollution concentrations in London for the years 2005, 2008, and 2010. Based on this detailed emissions and air pollution modeling, the areas in London were then identified that were expected to show the greatest changes in air pollution concentrations and population exposures after the implementation of the LEZ. Using these predictions, the best placement of a pollution monitoring network was determined and the feasibility of evaluating the health effects using electronic primary-care records was assessed. To measure baseline pollutant concentrations before the implementation of the LEZ, a comprehensive monitoring network was established close to major roadways and intersections. Output-difference plots from statistical modeling for 2010 indicated seven key areas likely to experience the greatest change in concentrations of nitrogen dioxide (NO2) (at least 3

  13. Nonintrusive methodology for wellness baseline profiling

    Science.gov (United States)

    Chung, Danny Wen-Yaw; Tsai, Yuh-Show; Miaou, Shaou-Gang; Chang, Walter H.; Chang, Yaw-Jen; Chen, Shia-Chung; Hong, Y. Y.; Chyang, C. S.; Chang, Quan-Shong; Hsu, Hon-Yen; Hsu, James; Yao, Wei-Cheng; Hsu, Ming-Sin; Chen, Ming-Chung; Lee, Shi-Chen; Hsu, Charles; Miao, Lidan; Byrd, Kenny; Chouikha, Mohamed F.; Gu, Xin-Bin; Wang, Paul C.; Szu, Harold

    2007-04-01

    We develop an accumulatively effective and affordable set of smart pair devices to save the exuberant expenditure for the healthcare of aging population, which will not be sustainable when all the post-war baby boomers retire (78 millions will cost 1/5~1/4 GDP in US alone). To design an accessible test-bed for distributed points of homecare, we choose two exemplars of the set to demonstrate the possibility of translation of modern military and clinical know-how, because two exemplars share identically the noninvasive algorithm adapted to the Smart Sensor-pairs for the real world persistent surveillance. Currently, the standard diagnoses for malignant tumors and diabetes disorders are blood serum tests, X-ray CAT scan, and biopsy used sometime in the physical checkup by physicians as cohort-average wellness baselines. The loss of the quality of life in making second careers productive may be caused by the missing of timeliness for correct diagnoses and easier treatments, which contributes to the one quarter of human errors generating the lawsuits against physicians and hospitals, which further escalates the insurance cost and wasteful healthcare expenditure. Such a vicious cycle should be entirely eliminated by building an "individual diagnostic aids (IDA)," similar to the trend of personalized drug, developed from daily noninvasive intelligent databases of the "wellness baseline profiling (WBP)". Since our physiology state undulates diurnally, the Nyquist anti-aliasing theory dictates a minimum twice-a-day sampling of the WBP for the IDA, which must be made affordable by means of noninvasive, unsupervised and unbiased methodology at the convenience of homes. Thus, a pair of military infrared (IR) spectral cameras has been demonstrated for the noninvasive spectrogram ratio test of the spontaneously emitted thermal radiation from a normal human body at 37°C temperature. This invisible self-emission spreads from 3 microns to 12 microns of the radiation wavelengths

  14. Baselining PMU Data to Find Patterns and Anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G.; Follum, James D.; Freeman, Kimberly A.; Dagle, Jeffery E.

    2016-10-25

    This paper looks at the application of situational awareness methodologies with respect to power grid data. These methodologies establish baselines that look for typical patterns and atypical behavior in the data. The objectives of the baselining analyses are to provide: real-time analytics, the capability to look at historical trends and events, and reliable predictions of the near future state of the grid. Multivariate algorithms were created to establish normal baseline behavior and then score each moment in time according to its variance from the baseline. Detailed multivariate analytical techniques are described in this paper that produced ways to identify typical patterns and atypical behavior. In this case, atypical behavior is behavior that is unenvisioned. Visualizations were also produced to help explain the behavior that was identified mathematically. Examples are shown to help describe how to read and interpret the analyses and visualizations. Preliminary work has been performed on PMU data sets from BPA (Bonneville Power Administration) and EI (Eastern Interconnect). Actual results are not fully shown here because of confidentiality issues. Comparisons between atypical events found mathematically and actual events showed that many of the actual events are also atypical events; however there are many atypical events that do not correlate to any actual events. Additional work needs to be done to help classify the atypical events into actual events, so that the importance of the events can be better understood.

  15. Measurement of baseline and orientation between distributed aerospace platforms.

    Science.gov (United States)

    Wang, Wen-Qin

    2013-01-01

    Distributed platforms play an important role in aerospace remote sensing, radar navigation, and wireless communication applications. However, besides the requirement of high accurate time and frequency synchronization for coherent signal processing, the baseline between the transmitting platform and receiving platform and the orientation of platform towards each other during data recording must be measured in real time. In this paper, we propose an improved pulsed duplex microwave ranging approach, which allows determining the spatial baseline and orientation between distributed aerospace platforms by the proposed high-precision time-interval estimation method. This approach is novel in the sense that it cancels the effect of oscillator frequency synchronization errors due to separate oscillators that are used in the platforms. Several performance specifications are also discussed. The effectiveness of the approach is verified by simulation results.

  16. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, B.C.; Menne, T.; Johansen, J.D.

    2008-01-01

    Background: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. Objectives: To examine associations of 21 allergens in the European baseline series to polysensitization....... Patients/Methods: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. Results...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization Udgivelsesdato: 2008...

  17. Associations between baseline allergens and polysensitization

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Menné, Torkil; Johansen, Jeanne Duus

    2008-01-01

    BACKGROUND: Identification of patients at risk of developing polysensitization is not possible at present. An association between weak sensitizers and polysensitization has been hypothesized. OBJECTIVES: To examine associations of 21 allergens in the European baseline series to polysensitization....... PATIENTS/METHODS: From a database-based study with 14 998 patients patch tested with the European baseline series between 1985 and 2005, a group of 759 (5.1%) patients were polysensitized. Odds ratios were calculated to determine the relative contribution of each allergen to polysensitization. RESULTS...... denominator for the association between the allergens and the polysensitization was apparent, and any association, whether positive or negative, was relatively low. Based on these results, sensitization to specific baseline allergens cannot be used as risk indicators for polysensitization....

  18. Baseline restoration technique based on symmetrical zero-area trapezoidal pulse shaper

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Guoqiang, E-mail: 24829500@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Yang, Jian, E-mail: 22105653@qq.com [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Hu, Tianyu; Ge, Liangquan [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China); Ouyang, Xiaoping [Northwest Institute of Nuclear Technology, Xi’an 710024,China (China); Zhang, Qingxian; Gu, Yi [Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan, Chengdu University of Technology, Chengdu 610059 (China)

    2017-06-21

    Since the baseline of the unipolar pulse shaper have the direct-current (DC) offset and drift, an additional baseline estimator is need to obtain baseline values in real-time. The bipolar zero-area (BZA) pulse shapers can be used for baseline restoration, but they cannot restrain the baseline drift due to their asymmetrical shape. In this study, three trapezoids are synthesized as a symmetrical zero-area (SZA) shape, which can remove the DC offset and restrain the baseline drift. This baseline restoration technique can be easily implemented in digital pulse processing (DPP) systems base on the recursive algorithm. To strengthen our approach, the iron's characteristic x-ray was detected using a Si-PIN diode detector. Compared with traditional trapezoidal pulse shapers, the SZA trapezoidal pulse shaper improved the energy resolution from 237 eV to 216 eV for the 6.403 keV Kα peak.

  19. Baseline methodologies for clean development mechanism projects

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M.K. (ed.); Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-15

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  20. Geochemical baseline studies of soil in Finland

    Science.gov (United States)

    Pihlaja, Jouni

    2017-04-01

    The soil element concentrations regionally vary a lot in Finland. Mostly this is caused by the different bedrock types, which are reflected in the soil qualities. Geological Survey of Finland (GTK) is carrying out geochemical baseline studies in Finland. In the previous phase, the research is focusing on urban areas and mine environments. The information can, for example, be used to determine the need for soil remediation, to assess environmental impacts or to measure the natural state of soil in industrial areas or mine districts. The field work is done by taking soil samples, typically at depth between 0-10 cm. Sampling sites are chosen to represent the most vulnerable areas when thinking of human impacts by possible toxic soil element contents: playgrounds, day-care centers, schools, parks and residential areas. In the mine districts the samples are taken from the areas locating outside the airborne dust effected areas. Element contents of the soil samples are then analyzed with ICP-AES and ICP-MS, Hg with CV-AAS. The results of the geochemical baseline studies are published in the Finnish national geochemical baseline database (TAPIR). The geochemical baseline map service is free for all users via internet browser. Through this map service it is possible to calculate regional soil baseline values using geochemical data stored in the map service database. Baseline data for 17 elements in total is provided in the map service and it can be viewed on the GTK's web pages (http://gtkdata.gtk.fi/Tapir/indexEN.html).

  1. Baseline methodologies for clean development mechanism projects

    International Nuclear Information System (INIS)

    Lee, M.K.; Shrestha, R.M.; Sharma, S.; Timilsina, G.R.; Kumar, S.

    2005-11-01

    The Kyoto Protocol and the Clean Development Mechanism (CDM) came into force on 16th February 2005 with its ratification by Russia. The increasing momentum of this process is reflected in more than 100 projects having been submitted to the CDM Executive Board (CDM-EB) for approval of the baselines and monitoring methodologies, which is the first step in developing and implementing CDM projects. A CDM project should result in a net decrease of GHG emissions below any level that would have resulted from other activities implemented in the absence of that CDM project. The 'baseline' defines the GHG emissions of activities that would have been implemented in the absence of a CDM project. The baseline methodology is the process/algorithm for establishing that baseline. The baseline, along with the baseline methodology, are thus the most critical element of any CDM project towards meeting the important criteria of CDM, which are that a CDM should result in 'real, measurable, and long term benefits related to the mitigation of climate change'. This guidebook is produced within the frame work of the United Nations Environment Programme (UNEP) facilitated 'Capacity Development for the Clean Development Mechanism (CD4CDM)' Project. This document is published as part of the projects effort to develop guidebooks that cover important issues such as project finance, sustainability impacts, legal framework and institutional framework. These materials are aimed to help stakeholders better understand the CDM and are believed to eventually contribute to maximize the effect of the CDM in achieving the ultimate goal of UNFCCC and its Kyoto Protocol. This Guidebook should be read in conjunction with the information provided in the two other guidebooks entitled, 'Clean Development Mechanism: Introduction to the CDM' and 'CDM Information and Guidebook' developed under the CD4CDM project. (BA)

  2. Way to increase the user access at the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg; Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2010-10-15

    Although the LCLS photon beam is meant for a single user, the baseline undulator is long enough to serve two users simultaneously. To this end, we propose a setup composed of two simple elements: an X-ray mirror pair for X-ray beam deflection, and a short (4 m-long) magnetic chicane, which creates an offset for mirror pair installation in the middle of the baseline undulator. The insertable mirror pair can be used for spatial separation of the X-ray beams generated in the first and in the second half of the baseline undulator. The method of deactivating one half and activating another half of the undulator is based on the rapid switching of the FEL amplification process. As proposed elsewhere, using a kicker installed upstream of the LCLS baseline undulator and an already existing corrector in the first half of the undulator, it is possible to rapidly switch the X-ray beam from one user to another, thus providing two active beamlines at any time. We present simulation results dealing with the LCLS baseline, and show that it is possible to generate two saturated SASE X-ray beams in the whole 0.8-8 keV photon energy range in the same baseline undulator. These can be exploited to serve two users. Implementation of the proposed technique does not perturb the baseline mode of operation of the LCLS undulator. Moreover, the magnetic chicane setup is very flexible, and can be used as a self-seeding setup too. We present simulation results for the LCLS baseline undulator with SHAB (second harmonic afterburner) and show that one can produce monochromatic radiation at the 2nd harmonic as well as at the 1st. We describe an efficient way for obtaining multi-user operation at the LCLS hard X-ray FEL. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezoelectric devices similar to those for X-ray phase retarders

  3. Pediatric Heart Transplantation: Transitioning to Adult Care (TRANSIT): Baseline Findings.

    Science.gov (United States)

    Grady, Kathleen L; Hof, Kathleen Van't; Andrei, Adin-Cristian; Shankel, Tamara; Chinnock, Richard; Miyamoto, Shelley; Ambardekar, Amrut V; Anderson, Allen; Addonizio, Linda; Latif, Farhana; Lefkowitz, Debra; Goldberg, Lee; Hollander, Seth A; Pham, Michael; Weissberg-Benchell, Jill; Cool, Nichole; Yancy, Clyde; Pahl, Elfriede

    2018-02-01

    Young adult solid organ transplant recipients who transfer from pediatric to adult care experience poor outcomes related to decreased adherence to the medical regimen. Our pilot trial for young adults who had heart transplant (HT) who transfer to adult care tests an intervention focused on increasing HT knowledge, self-management and self-advocacy skills, and enhancing support, as compared to usual care. We report baseline findings between groups regarding (1) patient-level outcomes and (2) components of the intervention. From 3/14 to 9/16, 88 subjects enrolled and randomized to intervention (n = 43) or usual care (n = 45) at six pediatric HT centers. Patient self-report questionnaires and medical records data were collected at baseline, and 3 and 6 months after transfer. For this report, baseline findings (at enrollment and prior to transfer to adult care) were analyzed using Chi-square and t-tests. Level of significance was p Baseline demographics were similar in the intervention and usual care arms: age 21.3 ± 3.2 vs 21.5 ± 3.3 years and female 44% vs 49%, respectively. At baseline, there were no differences between intervention and usual care for use of tacrolimus (70 vs 62%); tacrolimus level (mean ± SD = 6.5 ± 2.3 ng/ml vs 5.6 ± 2.3 ng/ml); average of the within patient standard deviation of the baseline mean tacrolimus levels (1.6 vs 1.3); and adherence to the medical regimen [3.6 ± 0.4 vs 3.5 ± 0.5 (1 = hardly ever to 4 = all of the time)], respectively. At baseline, both groups had a modest amount of HT knowledge, were learning self-management and self-advocacy, and perceived they were adequately supported. Baseline findings indicate that transitioning HT recipients lack essential knowledge about HT and have incomplete self-management and self-advocacy skills.

  4. Development Of Regional Climate Mitigation Baseline For A DominantAgro-Ecological Zone Of Karnataka, India

    Energy Technology Data Exchange (ETDEWEB)

    Sudha, P.; Shubhashree, D.; Khan, H.; Hedge, G.T.; Murthy, I.K.; Shreedhara, V.; Ravindranath, N.H.

    2007-06-01

    Setting a baseline for carbon stock changes in forest andland use sector mitigation projects is an essential step for assessingadditionality of the project. There are two approaches for settingbaselines namely, project-specific and regional baseline. This paperpresents the methodology adopted for estimating the land available formitigation, for developing a regional baseline, transaction cost involvedand a comparison of project-specific and regional baseline. The studyshowed that it is possible to estimate the potential land and itssuitability for afforestation and reforestation mitigation projects,using existing maps and data, in the dry zone of Karnataka, southernIndia. The study adopted a three-step approach for developing a regionalbaseline, namely: i) identification of likely baseline options for landuse, ii) estimation of baseline rates of land-use change, and iii)quantification of baseline carbon profile over time. The analysis showedthat carbon stock estimates made for wastelands and fallow lands forproject-specific as well as the regional baseline are comparable. Theratio of wasteland Carbon stocks of a project to regional baseline is1.02, and that of fallow lands in the project to regional baseline is0.97. The cost of conducting field studies for determination of regionalbaseline is about a quarter of the cost of developing a project-specificbaseline on a per hectare basis. The study has shown the reliability,feasibility and cost-effectiveness of adopting regional baseline forforestry sectormitigation projects.

  5. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    Science.gov (United States)

    Beaton, K. H.; Bloomberg, J. J.

    2016-01-01

    One of the greatest challenges for sensorimotor adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. This information could guide individually customized countermeasures, which would enable more efficient use of crew time and provide better outcomes. The principal aim of this work is to look for baseline performance metrics that relate to locomotor adaptability. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations ("noise") in motor performance, as a predictor of individual adaptive capabilities.

  6. Waste management project technical baseline description

    International Nuclear Information System (INIS)

    Sederburg, J.P.

    1997-01-01

    A systems engineering approach has been taken to describe the technical baseline under which the Waste Management Project is currently operating. The document contains a mission analysis, function analysis, requirement analysis, interface definitions, alternative analysis, system definition, documentation requirements, implementation definitions, and discussion of uncertainties facing the Project

  7. Baseline and Multimodal UAV GCS Interface Design

    Science.gov (United States)

    2013-07-01

    complete a computerized version of the NASA - TLX assessment of perceived mental workload. 2.3 Results The baseline condition ran smoothly and with...System MALE Medium-altitude, Long-endurance NASA - TLX NASA Task Load Index SA Situation Awareness TDT Tucker Davis Technologies UAV Uninhabited Aerial

  8. National Cyberethics, Cybersafety, Cybersecurity Baseline Study

    Science.gov (United States)

    Education Digest: Essential Readings Condensed for Quick Review, 2009

    2009-01-01

    This article presents findings from a study that explores the nature of the Cyberethics, Cybersafety, and Cybersecurity (C3) educational awareness policies, initiatives, curriculum, and practices currently taking place in the U.S. public and private K-12 educational settings. The study establishes baseline data on C3 awareness, which can be used…

  9. Guidance on Port Biological Baseline Surveys (PBBS)

    Digital Repository Service at National Institute of Oceanography (India)

    Awad, A.; Haag, F.; Anil, A.C.; Abdulla, A.

    This publication has been prepared by GBP, IOI, CSIR-NIO and IUCN in order to serve as guidance to those who are planning to carry out a port biological baseline survey, in particular in the context of Ballast Water Management. It has been drafted...

  10. Solid Waste Program technical baseline description

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, A.B.

    1994-07-01

    The system engineering approach has been taken to describe the technical baseline under which the Solid Waste Program is currently operating. The document contains a mission analysis, function analysis, system definition, documentation requirements, facility and project bases, and uncertainties facing the program.

  11. Toward Baseline Software Anomalies in NASA Missions

    Science.gov (United States)

    Layman, Lucas; Zelkowitz, Marvin; Basili, Victor; Nikora, Allen P.

    2012-01-01

    In this fast abstract, we provide preliminary findings an analysis of 14,500 spacecraft anomalies from unmanned NASA missions. We provide some baselines for the distributions of software vs. non-software anomalies in spaceflight systems, the risk ratings of software anomalies, and the corrective actions associated with software anomalies.

  12. Physics Potential of Long-Baseline Experiments

    Directory of Open Access Journals (Sweden)

    Sanjib Kumar Agarwalla

    2014-01-01

    Full Text Available The discovery of neutrino mixing and oscillations over the past decade provides firm evidence for new physics beyond the Standard Model. Recently, θ13 has been determined to be moderately large, quite close to its previous upper bound. This represents a significant milestone in establishing the three-flavor oscillation picture of neutrinos. It has opened up exciting prospects for current and future long-baseline neutrino oscillation experiments towards addressing the remaining fundamental questions, in particular the type of the neutrino mass hierarchy and the possible presence of a CP-violating phase. Another recent and crucial development is the indication of non-maximal 2-3 mixing angle, causing the octant ambiguity of θ23. In this paper, I will review the phenomenology of long-baseline neutrino oscillations with a special emphasis on sub-leading three-flavor effects, which will play a crucial role in resolving these unknowns. First, I will give a brief description of neutrino oscillation phenomenon. Then, I will discuss our present global understanding of the neutrino mass-mixing parameters and will identify the major unknowns in this sector. After that, I will present the physics reach of current generation long-baseline experiments. Finally, I will conclude with a discussion on the physics capabilities of accelerator-driven possible future long-baseline precision oscillation facilities.

  13. Scanner baseliner monitoring and control in high volume manufacturing

    Science.gov (United States)

    Samudrala, Pavan; Chung, Woong Jae; Aung, Nyan; Subramany, Lokesh; Gao, Haiyong; Gomez, Juan-Manuel

    2016-03-01

    We analyze performance of different customized models on baseliner overlay data and demonstrate the reduction in overlay residuals by ~10%. Smart Sampling sets were assessed and compared with the full wafer measurements. We found that performance of the grid can still be maintained by going to one-third of total sampling points, while reducing metrology time by 60%. We also demonstrate the feasibility of achieving time to time matching using scanner fleet manager and thus identify the tool drifts even when the tool monitoring controls are within spec limits. We also explore the scanner feedback constant variation with illumination sources.

  14. Baseline Vascular Cognitive Impairment Predicts the Course of Apathetic Symptoms After Stroke: The CASPER Study.

    Science.gov (United States)

    Douven, Elles; Köhler, Sebastian; Schievink, Syenna H J; van Oostenbrugge, Robert J; Staals, Julie; Verhey, Frans R J; Aalten, Pauline

    2018-03-01

    To examine the influence of vascular cognitive impairment (VCI) on the course of poststroke depression (PSD) and poststroke apathy (PSA). Included were 250 stroke patients who underwent neuropsychological and neuropsychiatric assessment 3 months after stroke (baseline) and at a 6- and 12-month follow-up after baseline. Linear mixed models tested the influence of VCI in at least one cognitive domain (any VCI) or multidomain VCI (VCI in multiple cognitive domains) at baseline and domain-specific VCI at baseline on levels of depression and apathy over time, with random effects for intercept and slope. Almost half of the patients showed any VCI at baseline, and any VCI was associated with increasing apathy levels from baseline to the 12-month follow-up. Patients with multidomain VCI had higher apathy scores at the 6- and 12-month follow-up compared with patients with VCI in a single cognitive domain. Domain-specific analyses showed that impaired executive function and slowed information processing speed went together with increasing apathy levels from baseline to 6- and 12-month follow-up. None of the cognitive variables predicted the course of depressive symptoms. Baseline VCI is associated with increasing apathy levels from baseline to the chronic stroke phase, whereas no association was found between baseline VCI and the course of depressive symptoms. Health professionals should be aware that apathy might be absent early after stroke but may evolve over time in patients with VCI. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. A novel type of very long baseline astronomical intensity interferometer

    Science.gov (United States)

    Borra, Ermanno F.

    2013-12-01

    This article presents a novel type of very long baseline astronomical interferometer that uses the fluctuations, as a function of time, of the intensity measured by a quadratic detector, which is a common type of astronomical detector. The theory on which the technique is based is validated by laboratory experiments. Its outstanding principal advantages comes from the fact that the angular structure of an astronomical object is simply determined from the visibility of the minima of the spectrum of the intensity fluctuations measured by the detector, as a function of the frequency of the fluctuations, while keeping the spacing between mirrors constant. This would allow a simple setup capable of high angular resolutions because it could use an extremely large baseline. Another major interest is that it allows for a more efficient use of telescope time because observations at a single baseline are sufficient, while amplitude and intensity interferometers need several observations at different baselines. The fact that one does not have to move the telescopes would also allow detecting faster time variations because having to move the telescopes sets a lower limit to the time variations that can be detected. The technique uses wave interaction effects and thus has some characteristics in common with intensity interferometry. A disadvantage of the technique, like in intensity interferometry, is that it needs strong sources if observing at high frequencies (e.g. the visible). This is a minor disadvantage in the radio region. At high frequencies, this disadvantage is mitigated by the fact that, like in intensity interferometry, the requirements of the optical quality of the mirrors used are far less severe than in amplitude interferometry so that poor quality large reflectors (e.g. Cherenkov telescopes) can be used in the optical region.

  16. Accelerated Best Basis Inventory Baselining Task

    International Nuclear Information System (INIS)

    SASAKI, L.M.

    2001-01-01

    The baselining effort was recently proposed to bring the Best-Basis Inventory (BBI) and Question No.8 of the Tank Interpretive Report (TIR) for all 177 tanks to the current standards and protocols and to prepare a TIR Question No.8 if one is not already available. This plan outlines the objectives and methodology of the accelerated BBI baselining task. BBI baselining meetings held during December 2000 resulted in a revised BBI methodology and an initial set of BBI creation rules to be used in the baselining effort. The objectives of the BBI baselining effort are to: (1) Provide inventories that are consistent with the revised BBI methodology and new BBI creation rules. (2) Split the total tank waste in each tank into six waste phases, as appropriate (Supernatant, saltcake solids, saltcake liquid, sludge solids, sludge liquid, and retained gas). In some tanks, the solids and liquid portions of the sludge and/or saltcake may be combined into a single sludge or saltcake phase. (3) Identify sampling events that are to be used for calculating the BBIs. (4) Update waste volumes for subsequent reconciliation with the Hanlon (2001) waste tank summary. (5) Implement new waste type templates. (6) Include any sample data that might have been unintentionally omitted in the previous BBI and remove any sample data that should not have been included. Sample data to be used in the BBI must be available on TWINS. (7) Ensure that an inventory value for each standard BBI analyte is provided for each waste component. Sample based inventories for supplemental BBI analytes will be included when available. (8) Provide new means and confidence interval reports if one is not already available and include uncertainties in reporting inventory values

  17. Mercury baseline levels in Flemish soils (Belgium)

    International Nuclear Information System (INIS)

    Tack, Filip M.G.; Vanhaesebroeck, Thomas; Verloo, Marc G.; Van Rompaey, Kurt; Ranst, Eric van

    2005-01-01

    It is important to establish contaminant levels that are normally present in soils to provide baseline data for pollution studies. Mercury is a toxic element of concern. This study was aimed at assessing baseline mercury levels in soils in Flanders. In a previous study, mercury contents in soils in Oost-Vlaanderen were found to be significantly above levels reported elsewhere. For the current study, observations were extended over two more provinces, West-Vlaanderen and Antwerpen. Ranges of soil Hg contents were distinctly higher in the province Oost-Vlaanderen (interquartile range from 0.09 to 0.43 mg/kg) than in the other provinces (interquartile ranges from 0.7 to 0.13 and 0.7 to 0.15 mg/kg for West-Vlaanderen and Antwerpen, respectively). The standard threshold method was applied to separate soils containing baseline levels of Hg from the data. Baseline concentrations for Hg were characterised by a median of 0.10 mg Hg/kg dry soil, an interquartile range from 0.07 to 0.14 mg/kg and a 90% percentile value of 0.30 mg/kg. The influence of soil properties such as clay and organic carbon contents, and pH on baseline Hg concentrations was not important. Maps of the spatial distribution of Hg levels showed that the province Oost-Vlaanderen exhibited zones with systematically higher Hg soil contents. This may be related to the former presence of many small-scale industries employing mercury in that region. - Increased mercury levels may reflect human activity

  18. Assessment of local GNSS baselines at co-location sites

    Science.gov (United States)

    Herrera Pinzón, Iván; Rothacher, Markus

    2018-01-01

    As one of the major contributors to the realisation of the International Terrestrial Reference System (ITRS), the Global Navigation Satellite Systems (GNSS) are prone to suffer from irregularities and discontinuities in time series. While often associated with hardware/software changes and the influence of the local environment, these discrepancies constitute a major threat for ITRS realisations. Co-located GNSS at fundamental sites, with two or more available instruments, provide the opportunity to mitigate their influence while improving the accuracy of estimated positions by examining data breaks, local biases, deformations, time-dependent variations and the comparison of GNSS baselines with existing local tie measurements. With the use of co-located GNSS data from a subset sites of the International GNSS Service network, this paper discusses a global multi-year analysis with the aim of delivering homogeneous time series of coordinates to analyse system-specific error sources in the local baselines. Results based on the comparison of different GNSS-based solutions with the local survey ties show discrepancies of up to 10 mm despite GNSS coordinate repeatabilities at the sub-mm level. The discrepancies are especially large for the solutions using the ionosphere-free linear combination and estimating tropospheric zenith delays, thus corresponding to the processing strategy used for global solutions. Snow on the antennas causes further problems and seasonal variations of the station coordinates. These demonstrate the need for a permanent high-quality monitoring of the effects present in the short GNSS baselines at fundamental sites.

  19. Predicting Baseline for Analysis of Electricity Pricing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Lee, D. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Choi, J. [Ulsan National Inst. of Science and Technology (Korea, Republic of); Spurlock, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sim, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wu, K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-03

    To understand the impact of new pricing structure on residential electricity demands, we need a baseline model that captures every factor other than the new price. The standard baseline is a randomized control group, however, a good control group is hard to design. This motivates us to devlop data-driven approaches. We explored many techniques and designed a strategy, named LTAP, that could predict the hourly usage years ahead. The key challenge in this process is that the daily cycle of electricity demand peaks a few hours after the temperature reaching its peak. Existing methods rely on the lagged variables of recent past usages to enforce this daily cycle. These methods have trouble making predictions years ahead. LTAP avoids this trouble by assuming the daily usage profile is determined by temperature and other factors. In a comparison against a well-designed control group, LTAP is found to produce accurate predictions.

  20. CASA Uno GPS orbit and baseline experiments

    Science.gov (United States)

    Schutz, B. E.; Ho, C. S.; Abusali, P. A. M.; Tapley, B. D.

    1990-01-01

    CASA Uno data from sites distributed in longitude from Australia to Europe have been used to determine orbits of the GPS satellites. The characteristics of the orbits determined from double difference phase have been evaluated through comparisons of two-week solutions with one-week solutions and by comparisons of predicted and estimated orbits. Evidence of unmodeled effects is demonstrated, particularly associated with the orbit planes that experience solar eclipse. The orbit accuracy has been assessed through the repeatability of unconstrained estimated baseline vectors ranging from 245 km to 5400 km. Both the baseline repeatability and the comparison with independent space geodetic methods give results at the level of 1-2 parts in 100,000,000. In addition, the Mojave/Owens Valley (245 km) and Kokee Park/Ft. Davis (5409 km) estimates agree with VLBI and SLR to better than 1 part in 100,000,000.

  1. Baseline composition of solar energetic particles

    International Nuclear Information System (INIS)

    Meyer, J.

    1985-01-01

    We analyze all existing spacecraft observations of the highly variable heavy element composition of solar energetic particles (SEP) during non- 3 He-rich events. All data show the imprint of an ever-present basic composition pattern (dubbed ''mass-unbiased baseline'' SEP composition) that differs from the photospheric composition by a simple bias related to first ionization potential (FIP). In each particular observation, this mass-unbiased baseline composition is being distorted by an additional bias, which is always a monotonic function of mass (or Z). This latter bias varies in amplitude and even sign from observation to observation. To first order, it seems related to differences in the A/Z* ratio between elements (Z* = mean effective charge)

  2. OCRWM baseline management procedure for document identifiers

    International Nuclear Information System (INIS)

    1993-03-01

    This procedure establishes a uniform numbering system (document identifier) for all Program and project technical, cost, and schedule baselines, and selected management and procurement documents developed for and controlled by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System (CRWMS). The document identifier defined in this procedure is structured to ensure that the relational integrity between configuration items (CIs) and their associated documentation and software is maintained, traceable, categorical, and retrievable for the life of the program

  3. Information Technology Sector Baseline Risk Assessment

    Science.gov (United States)

    2009-08-01

    alternative root be economically advantageous , an actor’s ability to exploit market forces and create an alternative root would be significantly improved...conduct their operations. Therefore, a loss or disruption to Internet services would not be advantageous for the desired outcomes of these syndicates.26... eCommerce Service loss or disruption [C] Traffic Redirection [C] = Undesired consequence Information Technology Sector Baseline Risk Assessment

  4. Spent nuclear fuel technical baseline description, Fiscal Year 1996: Volume II, supporting data

    International Nuclear Information System (INIS)

    Womack, J.C.

    1995-11-01

    The Technical Baseline Description documents the Project-Level functions and requirements, along with associated enabling assumptions, issues, trade studies, interfaces, and products. It is a snapshot in time of the baseline at the beginning of September 1995. It supports the individual subprojects in the development of lower-tier functions, requirements, and specifications in FY 1996. It also supports the need for Hanford site planning to be based on an integrated Hanford site systems engineering technical baseline; and is traceable to that baseline. This document replaces and supercedes WHC-SD-SNF-SD-003

  5. Base-line studies for DAE establishments

    International Nuclear Information System (INIS)

    Puranik, V.D.

    2012-01-01

    The Department of Atomic Energy has establishments located in various regions of the country and they include front-end fuel cycle facilities, nuclear power stations, back-end fuel cycle facilities and facilities for research and societal applications. These facilities handle naturally occurring radionuclides such as uranium, thorium and a variety of man-made radionuclides. These radionuclides are handled with utmost care so that they do not affect adversely the occupational workers or the members of public residing nearby. There is safety culture of the highest standard existing in all DAE establishments and it matches with the international standards. In addition, there is a perpetual environmental monitoring program carried out by the Environmental Survey Laboratories (ESLs) located at all DAE establishments. The environmental data generated by such program is studied regularly by experts to ensure compliance with the regulatory requirements. The regulatory requirements in the country are of international standards and ensure adequate protection of workers and members of public. In addition to such continued monitoring program and studies being carried out for the ongoing projects, base-line studies are carried out for all the new projects of the DAE. The purpose of the base-line studies is to establish a detailed base-line data set for a new DAE location well before the foundation stone is laid, so that the data collected when there is no departmental activity can be compared with the data generated later by the ESL. The data so generated is site specific and it varies from place to place depending upon the location of the site, e.g., inland or coastal, the presence of water bodies and pattern of irrigation, the geological characteristics of the location, the local culture and habits of the people, population density and urban or rural background. The data to be recorded as base-line data is generated over a period of at least one year covering all the seasons

  6. Pipeline integrity: ILI baseline data for QRA

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Todd R. [Tuboscope Pipeline Services, Houston, TX (United States)]. E-mail: tporter@varco.com; Silva, Jose Augusto Pereira da [Pipeway Engenharia, Rio de Janeiro, RJ (Brazil)]. E-mail: guto@pipeway.com; Marr, James [MARR and Associates, Calgary, AB (Canada)]. E-mail: jmarr@marr-associates.com

    2003-07-01

    The initial phase of a pipeline integrity management program (IMP) is conducting a baseline assessment of the pipeline system and segments as part of Quantitative Risk Assessment (QRA). This gives the operator's integrity team the opportunity to identify critical areas and deficiencies in the protection, maintenance, and mitigation strategies. As a part of data gathering and integration of a wide variety of sources, in-line inspection (ILI) data is a key element. In order to move forward in the integrity program development and execution, the baseline geometry of the pipeline must be determined with accuracy and confidence. From this, all subsequent analysis and conclusions will be derived. Tuboscope Pipeline Services (TPS), in conjunction with Pipeway Engenharia of Brazil, operate ILI inertial navigation system (INS) and Caliper geometry tools, to address this integrity requirement. This INS and Caliper ILI tool data provides pipeline trajectory at centimeter level resolution and sub-metre 3D position accuracy along with internal geometry - ovality, dents, misalignment, and wrinkle/buckle characterization. Global strain can be derived from precise INS curvature measurements and departure from the initial pipeline state. Accurate pipeline elevation profile data is essential in the identification of sag/over bend sections for fluid dynamic and hydrostatic calculations. This data, along with pipeline construction, operations, direct assessment and maintenance data is integrated in LinaViewPRO{sup TM}, a pipeline data management system for decision support functions, and subsequent QRA operations. This technology provides the baseline for an informed, accurate and confident integrity management program. This paper/presentation will detail these aspects of an effective IMP, and experience will be presented, showing the benefits for liquid and gas pipeline systems. (author)

  7. SRP Baseline Hydrogeologic Investigation, Phase 3

    Energy Technology Data Exchange (ETDEWEB)

    Bledsoe, H.W.

    1988-08-01

    The SRP Baseline Hydrogeologic Investigation was implemented for the purpose of updating and improving the knowledge and understanding of the hydrogeologic systems underlying the SRP site. Phase III, which is discussed in this report, includes the drilling of 7 deep coreholes (sites P-24 through P-30) and the installation of 53 observation wells ranging in depth from approximately 50 ft to more than 970 ft below the ground surface. In addition to the collection of geologic cores for lithologic and stratigraphic study, samples were also collected for the determination of physical characteristics of the sediments and for the identification of microorganisms.

  8. Environmental Baseline File for National Transportation

    International Nuclear Information System (INIS)

    1999-01-01

    This Environmental Baseline File summarizes and consolidates information related to the national-level transportation of commercial spent nuclear fuel. Topics address include: shipments of commercial spent nuclear fuel based on mostly truck and mostly rail shipping scenarios; transportation routing for commercial spent nuclear fuel sites and DOE sites; radionuclide inventories for various shipping container capacities; transportation routing; populations along transportation routes; urbanized area population densities; the impacts of historical, reasonably foreseeable, and general transportation; state-level food transfer factors; Federal Guidance Report No. 11 and 12 radionuclide dose conversion factors; and national average atmospheric conditions

  9. Baseline-dependent averaging in radio interferometry

    Science.gov (United States)

    Wijnholds, S. J.; Willis, A. G.; Salvini, S.

    2018-05-01

    This paper presents a detailed analysis of the applicability and benefits of baseline-dependent averaging (BDA) in modern radio interferometers and in particular the Square Kilometre Array. We demonstrate that BDA does not affect the information content of the data other than a well-defined decorrelation loss for which closed form expressions are readily available. We verify these theoretical findings using simulations. We therefore conclude that BDA can be used reliably in modern radio interferometry allowing a reduction of visibility data volume (and hence processing costs for handling visibility data) by more than 80 per cent.

  10. Spectrometer Baseline Control Via Spatial Filtering

    Science.gov (United States)

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  11. Neutrino physics with short baseline experiments

    International Nuclear Information System (INIS)

    Zimmerman, E.D.

    2006-01-01

    Neutrino physics with low- to medium-energy beams has progressed steadily over the last several years. Neutrino oscillation searches at short baseline (defined as 2 - -> 0.1eV 2 . One positive signal, from the LSND collaboration, exists and is being tested by the MiniBooNE experiment. Neutrino cross-section measurements are being made by MiniBooNE and K2K, which will be important for reducing systematic errors in present and future oscillation measurements. In the near future, dedicated cross- section experiments will begin operating at Fermilab. (author)

  12. Rationing in the presence of baselines

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Moreno-Ternero, Juan D.; Østerdal, Lars Peter

    2013-01-01

    We analyze a general model of rationing in which agents have baselines, in addition to claims against the (insufficient) endowment of the good to be allocated. Many real-life problems fit this general model (e.g., bankruptcy with prioritized claims, resource allocation in the public health care...... sector, water distribution in drought periods). We introduce (and characterize) a natural class of allocation methods for this model. Any method within the class is associated with a rule in the standard rationing model, and we show that if the latter obeys some focal properties, the former obeys them...

  13. Baseline scenarios of global environmental change

    International Nuclear Information System (INIS)

    Alcamo, J.; Kreileman, G.J.J.; Bollen, J.C.; Born, G.J. van den; Krol, M.S.; Toet, A.M.C.; Vries, H.J.M. de; Gerlagh, R.

    1996-01-01

    This paper presents three baseline scenarios of no policy action computed by the IMAGE2 model. These scenarios cover a wide range of coupled global change indicators, including: energy demand and consumption; food demand, consumption, and production; changes in land cover including changes in extent of agricultural land and forest; emissions of greenhouse gases and ozone precursors; and climate change and its impacts on sea level rise, crop productivity and natural vegetation. Scenario information is available for the entire world with regional and grid scale detail, and covers from 1970 to 2100. (author)

  14. SRP baseline hydrogeologic investigation: Aquifer characterization

    Energy Technology Data Exchange (ETDEWEB)

    Strom, R.N.; Kaback, D.S.

    1992-03-31

    An investigation of the mineralogy and chemistry of the principal hydrogeologic units and the geochemistry of the water in the principal aquifers at Savannah River Site (SRS) was undertaken as part of the Baseline Hydrogeologic Investigation. This investigation was conducted to provide background data for future site studies and reports and to provide a site-wide interpretation of the geology and geochemistry of the Coastal Plain Hydrostratigraphic province. Ground water samples were analyzed for major cations and anions, minor and trace elements, gross alpha and beta, tritium, stable isotopes of hydrogen, oxygen, and carbon, and carbon-14. Sediments from the well borings were analyzed for mineralogy and major and minor elements.

  15. Analysis of baseline gene expression levels from ...

    Science.gov (United States)

    The use of gene expression profiling to predict chemical mode of action would be enhanced by better characterization of variance due to individual, environmental, and technical factors. Meta-analysis of microarray data from untreated or vehicle-treated animals within the control arm of toxicogenomics studies has yielded useful information on baseline fluctuations in gene expression. A dataset of control animal microarray expression data was assembled by a working group of the Health and Environmental Sciences Institute's Technical Committee on the Application of Genomics in Mechanism Based Risk Assessment in order to provide a public resource for assessments of variability in baseline gene expression. Data from over 500 Affymetrix microarrays from control rat liver and kidney were collected from 16 different institutions. Thirty-five biological and technical factors were obtained for each animal, describing a wide range of study characteristics, and a subset were evaluated in detail for their contribution to total variability using multivariate statistical and graphical techniques. The study factors that emerged as key sources of variability included gender, organ section, strain, and fasting state. These and other study factors were identified as key descriptors that should be included in the minimal information about a toxicogenomics study needed for interpretation of results by an independent source. Genes that are the most and least variable, gender-selectiv

  16. Long-baseline neutrino oscillation experiments

    International Nuclear Information System (INIS)

    Crane, D.; Goodman, M.

    1994-01-01

    There is no unambiguous definition for long baseline neutrino oscillation experiments. The term is generally used for accelerator neutrino oscillation experiments which are sensitive to Δm 2 2 , and for which the detector is not on the accelerator site. The Snowmass N2L working group met to discuss the issues facing such experiments. The Fermilab Program Advisory Committee adopted several recommendations concerning the Fermilab neutrino program at their Aspen meeting immediately prior to the Snowmass Workshop. This heightened the attention for the proposals to use Fermilab for a long-baseline neutrino experiment at the workshop. The plan for a neutrino oscillation program at Brookhaven was also thoroughly discussed. Opportunities at CERN were considered, particularly the use of detectors at the Gran Sasso laboratory. The idea to build a neutrino beam from KEK towards Superkamiokande was not discussed at the Snowmass meeting, but there has been considerable development of this idea since then. Brookhaven and KEK would use low energy neutrino beams, while FNAL and CERN would plan have medium energy beams. This report will summarize a few topics common to LBL proposals and attempt to give a snapshot of where things stand in this fast developing field

  17. Baseline response rates affect resistance to change.

    Science.gov (United States)

    Kuroda, Toshikazu; Cook, James E; Lattal, Kennon A

    2018-01-01

    The effect of response rates on resistance to change, measured as resistance to extinction, was examined in two experiments. In Experiment 1, responding in transition from a variable-ratio schedule and its yoked-interval counterpart to extinction was compared with pigeons. Following training on a multiple variable-ratio yoked-interval schedule of reinforcement, in which response rates were higher in the former component, reinforcement was removed from both components during a single extended extinction session. Resistance to extinction in the yoked-interval component was always either greater or equal to that in the variable-ratio component. In Experiment 2, resistance to extinction was compared for two groups of rats that exhibited either high or low response rates when maintained on identical variable-interval schedules. Resistance to extinction was greater for the lower-response-rate group. These results suggest that baseline response rate can contribute to resistance to change. Such effects, however, can only be revealed when baseline response rate and reinforcement rate are disentangled (Experiments 1 and 2) from the more usual circumstance where the two covary. Furthermore, they are more cleanly revealed when the programmed contingencies controlling high and low response rates are identical, as in Experiment 2. © 2017 Society for the Experimental Analysis of Behavior.

  18. Baseline Response Levels Are a Nuisance in Infant Contingency Learning

    Science.gov (United States)

    Millar, W. S.; Weir, Catherine

    2015-01-01

    The impact of differences in level of baseline responding on contingency learning in the first year was examined by considering the response acquisition of infants classified into baseline response quartiles. Whereas the three lower baseline groups showed the predicted increment in responding to a contingency, the highest baseline responders did…

  19. 33 CFR 2.20 - Territorial sea baseline.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line.... Normally, the territorial sea baseline is the mean low water line along the coast of the United States...

  20. Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

    Science.gov (United States)

    Beaton, K. H.; Bloomberg, J. J.

    2014-01-01

    One of the greatest challenges surrounding adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. Such knowledge could guide individually customized countermeasures, which would enable more efficient use of crew time, both preflight and inflight, and provide better outcomes. The primary goal of this project is to look for a baseline performance metric that can forecast sensorimotor adaptability without exposure to an adaptive stimulus. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations in motor performance, as a predictor of individual sensorimotor adaptive capabilities. To-date, a strong relationship has been found between baseline inter-trial correlations and adaptability in two oculomotor systems. For this project, we will explore an analogous predictive mechanism in the locomotion system. METHODS: Baseline Inter-trial Correlations: Inter-trial correlations specify the relationships among repeated trials of a given task that transpire as a consequence of correcting for previous performance errors over multiple timescales. We can quantify the strength of inter-trial correlations by measuring the decay of the autocorrelation function (ACF), which describes how rapidly information from past trials is "forgotten." Processes whose ACFs decay more slowly exhibit longer-term inter-trial correlations (longer memory processes), while processes whose ACFs decay more rapidly exhibit shorterterm inter-trial correlations (shorter memory processes). Longer-term correlations reflect low-frequency activity, which is more easily

  1. The WITCH Model. Structure, Baseline, Solutions.

    Energy Technology Data Exchange (ETDEWEB)

    Bosetti, V.; Massetti, E.; Tavoni, M.

    2007-07-01

    WITCH - World Induced Technical Change Hybrid - is a regionally disaggregated hard link hybrid global model with a neoclassical optimal growth structure (top down) and an energy input detail (bottom up). The model endogenously accounts for technological change, both through learning curves affecting prices of new vintages of capital and through R and D investments. The model features the main economic and environmental policies in each world region as the outcome of a dynamic game. WITCH belongs to the class of Integrated Assessment Models as it possesses a climate module that feeds climate changes back into the economy. In this paper we provide a thorough discussion of the model structure and baseline projections. We report detailed information on the evolution of energy demand, technology and CO2 emissions. Finally, we explicitly quantifiy the role of free riding in determining the emissions scenarios. (auth)

  2. Global Nuclear Energy Partnership Waste Treatment Baseline

    International Nuclear Information System (INIS)

    Gombert, Dirk; Ebert, William; Marra, James; Jubin, Robert; Vienna, John

    2008-01-01

    The Global Nuclear Energy Partnership (GNEP) program is designed to demonstrate that a proliferation-resistant and sustainable integrated nuclear fuel cycle can be commercialized and used internationally. Alternative stabilization concepts for byproducts and waste streams generated by fuel recycling processes were evaluated and a baseline set of waste forms was recommended for the safe disposition of waste streams. Specific waste forms are recommended based on the demonstrated or expected commercial practicability and technical maturity of the processes needed to make the waste forms, and expected performance of the waste form materials when disposed. Significant issues remain in developing technologies to process some of the wastes into the recommended waste forms, and a detailed analysis of technology readiness may lead to the choice of a different waste form than what is recommended herein. Evolving regulations could also affect the selection of waste forms. (authors)

  3. Global Nuclear Energy Partnership Waste Treatment Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Gombert, Dirk; Ebert, William; Marra, James; Jubin, Robert; Vienna, John [Idaho National laboratory, 2525 Fremont Ave., Idaho Falls, ID 83402 (United States)

    2008-07-01

    The Global Nuclear Energy Partnership (GNEP) program is designed to demonstrate that a proliferation-resistant and sustainable integrated nuclear fuel cycle can be commercialized and used internationally. Alternative stabilization concepts for byproducts and waste streams generated by fuel recycling processes were evaluated and a baseline set of waste forms was recommended for the safe disposition of waste streams. Specific waste forms are recommended based on the demonstrated or expected commercial practicability and technical maturity of the processes needed to make the waste forms, and expected performance of the waste form materials when disposed. Significant issues remain in developing technologies to process some of the wastes into the recommended waste forms, and a detailed analysis of technology readiness may lead to the choice of a different waste form than what is recommended herein. Evolving regulations could also affect the selection of waste forms. (authors)

  4. Global Nuclear Energy Partnership Waste Treatment Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Dirk Gombert; William Ebert; James Marra; Robert Jubin; John Vienna

    2008-05-01

    The Global Nuclear Energy Partnership program (GNEP) is designed to demonstrate a proliferation-resistant and sustainable integrated nuclear fuel cycle that can be commercialized and used internationally. Alternative stabilization concepts for byproducts and waste streams generated by fuel recycling processes were evaluated and a baseline of waste forms was recommended for the safe disposition of waste streams. Waste forms are recommended based on the demonstrated or expected commercial practicability and technical maturity of the processes needed to make the waste forms, and performance of the waste form materials when disposed. Significant issues remain in developing technologies to process some of the wastes into the recommended waste forms, and a detailed analysis of technology readiness and availability may lead to the choice of a different waste form than what is recommended herein. Evolving regulations could also affect the selection of waste forms.

  5. On the feasibility of routine baseline improvement in processing of geomagnetic observatory data

    Science.gov (United States)

    Soloviev, Anatoly; Lesur, Vincent; Kudin, Dmitry

    2018-02-01

    We propose a new approach to the calculation of regular baselines at magnetic observatories. The proposed approach is based on the simultaneous analysis of the irregular absolute observations and the continuous time-series deltaF, widely used for estimating the data quality. The systematic deltaF analysis allows to take into account all available information about the operation of observatory instruments (i.e., continuous records of the field variations and its modulus) in the intervals between the times of absolute observations, as compared to the traditional baseline calculation where only spot values are considered. To establish a connection with the observed spot baseline values, we introduce a function for approximate evaluation of the intermediate baseline values. An important feature of the algorithm is its quantitative estimation of the resulting data precision and thus determination of the problematic fragments in raw data. We analyze the robustness of the algorithm operation using synthetic data sets. We also compare baselines and definitive data derived by the proposed algorithm with those derived by the traditional approach using Saint Petersburg observatory data, recorded in 2015 and accepted by INTERMAGNET. It is shown that the proposed method allows to essentially improve the resulting data quality when baseline data are not good enough. The obtained results prove that the baseline variability in time might be quite rapid.[Figure not available: see fulltext.

  6. Baseline neurocognitive testing in sports-related concussions: the importance of a prior night's sleep.

    Science.gov (United States)

    McClure, D Jake; Zuckerman, Scott L; Kutscher, Scott J; Gregory, Andrew J; Solomon, Gary S

    2014-02-01

    The management of sports-related concussions (SRCs) utilizes serial neurocognitive assessments and self-reported symptom inventories to assess recovery and safety for return to play (RTP). Because postconcussive RTP goals include symptom resolution and a return to neurocognitive baseline levels, clinical decisions rest in part on understanding modifiers of this baseline. Several studies have reported age and sex to influence baseline neurocognitive performance, but few have assessed the potential effect of sleep. We chose to investigate the effect of reported sleep duration on baseline Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) performance and the number of patient-reported symptoms. We hypothesized that athletes receiving less sleep before baseline testing would perform worse on neurocognitive metrics and report more symptoms. Cross-sectional study; Level of evidence, 3. We retrospectively reviewed 3686 nonconcussed athletes (2371 male, 1315 female; 3305 high school, 381 college) with baseline symptom and ImPACT neurocognitive scores. Patients were stratified into 3 groups based on self-reported sleep duration the night before testing: (1) short, sleep duration on baseline ImPACT performance. A univariate ANCOVA was performed to investigate the influence of sleep on total self-reported symptoms. When controlling for age and sex as covariates, the MANCOVA revealed significant group differences on ImPACT reaction time, verbal memory, and visual memory scores but not visual-motor (processing) speed scores. An ANCOVA also revealed significant group differences in total reported symptoms. For baseline symptoms and ImPACT scores, subsequent pairwise comparisons revealed these associations to be most significant when comparing the short and intermediate sleep groups. Our results indicate that athletes sleeping fewer than 7 hours before baseline testing perform worse on 3 of 4 ImPACT scores and report more symptoms. Because SRC management and RTP

  7. 40 CFR 80.915 - How are the baseline toxics value and baseline toxics volume determined?

    Science.gov (United States)

    2010-07-01

    ... baseline toxics value if it can determine an applicable toxics value for every batch of gasoline produced... of gasoline batch i produced or imported between January 1, 1998 and December 31, 2000, inclusive. i = Individual batch of gasoline produced or imported between January 1, 1998 and December 31, 2000, inclusive. n...

  8. Pakistan, Sindh Province - Baseline Indicators System : Baseline Procurement Performance Assessment Report

    OpenAIRE

    World Bank

    2009-01-01

    This document provides an assessment of the public procurement system in Sindh province using the baseline indicators system developed by the Development Assistance Committee of the Organization for Economic Cooperation and Development (OECD-DAC). This assessment, interviews and discussions were held with stakeholders from the public and private sectors as well as civil society. Developing...

  9. Integrating risk management into the baselining process

    International Nuclear Information System (INIS)

    Jennett, N.; Tonkinson, A.

    1994-01-01

    These processes work together in building the project (comprised of the technical, schedule, and cost baselines) against which performance is measured and changes to the scope, schedule and cost of a project are managed and controlled. Risk analysis is often performed as the final element of the scheduling or estimating processes, a precursor to establishing cost and schedule contingency. However, best business practices dictate that information that may be crucial to the success of a project be analyzed and incorporated into project planning as soon as it is available and usable. The purpose or risk management is not to eliminate risk. Neither is it intended to suggest wholesale re-estimating and re-scheduling of a project. Rather, the intent is to make provisions to reduce and control the schedule and/or cost ramifications of risk by anticipating events and conditions that cannot be reliably planned for and which have the potential to negatively impact accomplishment of the technical objectives and requirements of the project

  10. Shifting environmental baselines in the Red Sea.

    Science.gov (United States)

    Price, A R G; Ghazi, S J; Tkaczynski, P J; Venkatachalam, A J; Santillan, A; Pancho, T; Metcalfe, R; Saunders, J

    2014-01-15

    The Red Sea is among the world's top marine biodiversity hotspots. We re-examined coastal ecosystems at sites surveyed during the 1980s using the same methodology. Coral cover increased significantly towards the north, mirroring the reverse pattern for mangroves and other sedimentary ecosystems. Latitudinal patterns are broadly consistent across both surveys and with results from independent studies. Coral cover showed greatest change, declining significantly from a median score of 4 (1000-9999 m(2)) to 2 (10-99m(2)) per quadrat in 2010/11. This may partly reflect impact from coastal construction, which was evident at 40% of sites and has significantly increased in magnitude over 30 years. Beach oil has significantly declined, but shore debris has increased significantly. Although substantial, levels are lower than at some remote ocean atolls. While earlier reports have suggested that the Red Sea is generally healthy, shifting environmental baselines are evident from the current study. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Regional geochemical baselines for Portuguese shelf sediments

    International Nuclear Information System (INIS)

    Mil-Homens, M.; Stevens, R.L.; Cato, I.; Abrantes, F.

    2007-01-01

    Metal concentrations (Al, Cr, Cu, Ni, Pb and Zn) from the DGM-INETI archive data set have been examined for sediments collected during the 1970s from 267 sites on the Portuguese shelf. Due to the differences in the oceanographic and sedimentological settings between western and Algarve coasts, the archive data set is split in two segments. For both shelf segments, regional geochemical baselines (RGB) are defined using aluminium as a reference element. Seabed samples recovered in 2002 from four distinct areas of the Portuguese shelf are superimposed on these models to identify and compare possible metal enrichments relative to the natural distribution. Metal enrichments associated with anthropogenic influences are identified in three samples collected nearby the Tejo River and are characterised by the highest enrichment factors (EF; EF Pb Zn < 4). EF values close to 1 suggest a largely natural origin for metal distributions in sediments from the other areas included in the study. - Background metal concentrations and their natural variability must be established before assessing anthropogenic impacts

  12. Arc melter demonstration baseline test results

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O'Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process

  13. LTC vacuum blasting machine (concrete): Baseline report

    International Nuclear Information System (INIS)

    1997-01-01

    The LTC shot blast technology was tested and is being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The LTC 1073 Vacuum Blasting Machine uses a high-capacity, direct-pressure blasting system which incorporates a continuous feed for the blast media. The blast media cleans the surface within the contained brush area of the blast. It incorporates a vacuum system which removes dust and debris from the surface as it is blasted. The safety and health evaluation during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure during maintenance activities was minimal, but due to mechanical difficulties dust monitoring could not be conducted during operation. Noise exposure was significant. Further testing for each of these exposures is recommended because of the outdoor environment where the testing demonstration took place. This may cause the results to be inaccurate. It is feasible that the dust and noise levels will be higher in an enclosed environment. In addition, other safety and health issues found were ergonomics, heat stress, tripping hazards, electrical hazards, lockout/tagout, and arm-hand vibration

  14. FAIR - Baseline technical report. Executive summary

    International Nuclear Information System (INIS)

    Gutbrod, H.H.; Augustin, I.; Eickhoff, H.; Gross, K.D.; Henning, W.F.; Kraemer, D.; Walter, G.

    2006-09-01

    This document presents the Executive Summary, the first of six volumes comprising the 2006 Baseline Technical Report (BTR) for the international FAIR project (Facility for Antiproton and Ion Research). The BTR provides the technical description, cost, schedule, and assessments of risk for the proposed new facility. The purpose of the BTR is to provide a reliable basis for the construction, commissioning and operation of FAIR. The BTR is one of the central documents requested by the FAIR International Steering Committee (ISC) and its working groups, in order to prepare the legal process and the decisions on the construction and operation of FAIR in an international framework. It provides the technical basis for legal contracts on contributions to be made by, so far, 13 countries within the international FAIR Consortium. The BTR begins with this extended Executive Summary as Volume 1, which is also intended for use as a stand-alone document. The Executive Summary provides brief summaries of the accelerator facilities, the scientific programs and experimental stations, civil construction and safety, and of the workproject structure, costs and schedule. (orig.)

  15. Pentek metal coating removal system: Baseline report

    International Nuclear Information System (INIS)

    1997-01-01

    The Pentek coating removal technology was tested and is being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek coating removal system consisted of the ROTO-PEEN Scaler, CORNER-CUTTER reg-sign, and VAC-PAC reg-sign. They are designed to remove coatings from steel, concrete, brick, and wood. The Scaler uses 3M Roto Peen tungsten carbide cutters while the CORNER-CUTTER reg-sign uses solid needles for descaling activities. These hand tools are used with the VAC-PAC reg-sign vacuum system to capture dust and debris as removal of the coating takes place. The safety and health evaluation during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure minimal, but noise exposure was significant. Further testing for each exposure is recommended because of the environment where the testing demonstration took place. It is feasible that the dust and noise levels will be higher in an enclosed operating environment of different construction. In addition, other areas of concern found were arm-hand vibration, whole-body, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout

  16. 200-UP-2 Operable Unit technical baseline report

    International Nuclear Information System (INIS)

    Deford, D.H.

    1991-02-01

    This report is prepared in support of the development of a Remedial Investigation/Feasibility Study (RI/FS) Work Plan for the 200-UP-2 Operable Unit by EBASCO Environmental, Incorporated. It provides a technical baseline of the 200-UP-2 Operable Unit and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The 200-UP-2 Operable Unit Technical Baseline Report is based on review and evaluation of numerous Hanford Site current and historical reports, Hanford Site drawings and photographs and is supplemented with Hanford Site inspections and employee interviews. No field investigations or sampling were conducted. Each waste site in the 200-UP-2 Operable Unit is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. The 200-UP-2 Operable Unit consists of liquid-waste disposal sites in the vicinity of, and related to, U Plant operations in the 200 West Area of the Hanford Site. The ''U Plant'' refers to the 221-U Process Canyon Building, a chemical separations facility constructed during World War 2. It also includes the Uranium Oxide (UO 3 ) Plant, which was constructed at the same time and, like the 221-U Process Canyon Building, was later converted for other missions. Waste sites in the 200-UP-2 Operable Unit are associated with the U Plant Uranium Metal Recovery Program mission that occurred between 1952 and 1958 and the UO 3 Plant's ongoing uranium oxide mission and include one or more cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, waste vaults, and the lines and encasements that connect them. 11 refs., 1 tab

  17. Re-creating missing population baselines for Pacific reef sharks.

    Science.gov (United States)

    Nadon, Marc O; Baum, Julia K; Williams, Ivor D; McPherson, Jana M; Zgliczynski, Brian J; Richards, Benjamin L; Schroeder, Robert E; Brainard, Russell E

    2012-06-01

    Sharks and other large predators are scarce on most coral reefs, but studies of their historical ecology provide qualitative evidence that predators were once numerous in these ecosystems. Quantifying density of sharks in the absence of humans (baseline) is, however, hindered by a paucity of pertinent time-series data. Recently researchers have used underwater visual surveys, primarily of limited spatial extent or nonstandard design, to infer negative associations between reef shark abundance and human populations. We analyzed data from 1607 towed-diver surveys (>1 ha transects surveyed by observers towed behind a boat) conducted at 46 reefs in the central-western Pacific Ocean, reefs that included some of the world's most pristine coral reefs. Estimates of shark density from towed-diver surveys were substantially lower (sharks observed in towed-diver surveys and human population in models that accounted for the influence of oceanic primary productivity, sea surface temperature, reef area, and reef physical complexity. We used these models to estimate the density of sharks in the absence of humans. Densities of gray reef sharks (Carcharhinus amblyrhynchos), whitetip reef sharks (Triaenodon obesus), and the group "all reef sharks" increased substantially as human population decreased and as primary productivity and minimum sea surface temperature (or reef area, which was highly correlated with temperature) increased. Simulated baseline densities of reef sharks under the absence of humans were 1.1-2.4/ha for the main Hawaiian Islands, 1.2-2.4/ha for inhabited islands of American Samoa, and 0.9-2.1/ha for inhabited islands in the Mariana Archipelago, which suggests that density of reef sharks has declined to 3-10% of baseline levels in these areas. ©2012 Society for Conservation Biology No claim to original US government works.

  18. 100-D Area technical baseline report

    International Nuclear Information System (INIS)

    Carpenter, R.W.

    1993-01-01

    This document is prepared in support of the 100 Area Environmental Restoration activity at the US Department of Energy's Hanford Site near Richland, Washington. It provides a technical baseline of waste sites located at the 100-D Area. The report is based on an environmental investigation undertaken by the Westinghouse Hanford Company (WHC) History Office in support of the Environmental Restoration Engineering Function and on review and evaluation of numerous Hanford Site current and historical reports, drawings, and photographs, supplemented by site inspections and employee interviews. No intrusive field investigation or sampling was conducted. All Hanford coordinate locations are approximate locations taken from several different maps and drawings of the 100-D Area. Every effort was made to derive coordinate locations for the center of each facility or waste site, except where noted, using standard measuring devices. Units of measure are shown as they appear in reference documents. The 100-D Area is made up of three operable units: 100-DR-1, 100-DR-2, and 100-DR-3. All three are addressed in this report. These operable units include liquid and solid waste disposal sites in the vicinity of, and related to, the 100-D and 100-DR Reactors. A fourth operable unit, 100-HR-3, is concerned with groundwater and is not addressed here. This report describes waste sites which include cribs, trenches, pits, french drains, retention basins, solid waste burial grounds, septic tanks, and drain fields. Each waste site is described separately and photographs are provided where available. A complete list of photographs can be found in Appendix A. A comprehensive environmental summary is not provided here but may be found in Hanford Site National Environmental Policy Act Characterization (Cushing 1988), which describes the geology and soils, meteorology, hydrology, land use, population, and air quality of the area

  19. 1993 baseline solid waste management system description

    International Nuclear Information System (INIS)

    Armacost, L.L.; Fowler, R.A.; Konynenbelt, H.S.

    1994-02-01

    Pacific Northwest Laboratory has prepared this report under the direction of Westinghouse Hanford Company. The report provides an integrated description of the system planned for managing Hanford's solid low-level waste, low-level mixed waste, transuranic waste, and transuranic mixed waste. The primary purpose of this document is to illustrate a collective view of the key functions planned at the Hanford Site to handle existing waste inventories, as well as solid wastes that will be generated in the future. By viewing this system as a whole rather than as individual projects, key facility interactions and requirements are identified and a better understanding of the overall system may be gained. The system is described so as to form a basis for modeling the system at various levels of detail. Model results provide insight into issues such as facility capacity requirements, alternative system operating strategies, and impacts of system changes (ie., startup dates). This description of the planned Hanford solid waste processing system: defines a baseline system configuration; identifies the entering waste streams to be managed within the system; identifies basic system functions and waste flows; and highlights system constraints. This system description will evolve and be revised as issues are resolved, planning decisions are made, additional data are collected, and assumptions are tested and changed. Out of necessity, this document will also be revised and updated so that a documented system description, which reflects current system planning, is always available for use by engineers and managers. It does not provide any results generated from the many alternatives that will be modeled in the course of analyzing solid waste disposal options; such results will be provided in separate documents

  20. The very-long-baseline array

    International Nuclear Information System (INIS)

    Kellermann, K.I.; Thompson, A.R.

    1988-01-01

    The development of radio technology in World War II opened a completely new window on the universe. When astronomers turned radio antennas to the heavens, they began to find a previously unknown universe of solar and planetary radio bursts, quasars, pulsars, radio galaxies, giant molecular clouds and cosmic masers. Not only do the radio waves reveal a new world of astronomical phenomena but also-because they are much longer than light waves-they are not as severely distorted by atmospheric turbulence or small imperfections in the telescope. About 25 years ago radio astronomers became aware that they could synthesize a resolution equivalent to that of a large aperture by combining data from smaller radio antennas that are widely separated. The effective aperture size would be about equal to the largest separation between the antennas. The technique is called synthesis imaging and is based on the principles of interferometry. Radio astronomers in the U.S. are now building a synthesis radio telescope called the Very-Long-Baseline Array, or VLBA. With 10 antennas sited across the country from the Virgin Islands to Hawaii, it will synthesize a radio antenna 8,000 kilometers across, nearly the diameter of the earth. The VLBA'S angular resolution will be less than a thousandth of an arc-second-about three orders of magnitude better than that of the largest conventional ground-based optical telescopes. Astronomers eagerly await the completion early in the next decade of the VLBA, which is expected, among other things, to give an unprecedentedly clear view into the cores of quasars and galactic nuclei and to reveal details of the processe-thought to be powered by black holes-that drive them

  1. Drawing a baseline in aesthetic quality assessment

    Science.gov (United States)

    Rubio, Fernando; Flores, M. Julia; Puerta, Jose M.

    2018-04-01

    Aesthetic classification of images is an inherently subjective task. There does not exist a validated collection of images/photographs labeled as having good or bad quality from experts. Nowadays, the closest approximation to that is to use databases of photos where a group of users rate each image. Hence, there is not a unique good/bad label but a rating distribution given by users voting. Due to this peculiarity, it is not possible to state the problem of binary aesthetic supervised classification in such a direct mode as other Computer Vision tasks. Recent literature follows an approach where researchers utilize the average rates from the users for each image, and they establish an arbitrary threshold to determine their class or label. In this way, images above the threshold are considered of good quality, while images below the threshold are seen as bad quality. This paper analyzes current literature, and it reviews those attributes able to represent an image, differentiating into three families: specific, general and deep features. Among those which have been proved more competitive, we have selected a representative subset, being our main goal to establish a clear experimental framework. Finally, once features were selected, we have used them for the full AVA dataset. We have to remark that to perform validation we report not only accuracy values, which is not that informative in this case, but also, metrics able to evaluate classification power within imbalanced datasets. We have conducted a series of experiments so that distinct well-known classifiers are learned from data. Like that, this paper provides what we could consider valuable and valid baseline results for the given problem.

  2. 10 CFR 850.20 - Baseline beryllium inventory.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Baseline beryllium inventory. 850.20 Section 850.20 Energy... Baseline beryllium inventory. (a) The responsible employer must develop a baseline inventory of the... inventory, the responsible employer must: (1) Review current and historical records; (2) Interview workers...

  3. A study of man made radioactivity baseline in dietary materials

    International Nuclear Information System (INIS)

    de la Paz, L.; Estacio, J.; Palattao, M.V.; Anden, A.

    1986-01-01

    This paper describes the radioactivity baseline from literature data coming from various countries where data are available. 1979-1985 were chosen as the baseline years for the following: milk (fresh and powdered), meat and meat products, cereals, fruits, coffee and tea, fish and vegetables. Pre- and post-Chernobyl baseline data are given. (ELC). 21 figs; 17 refs

  4. 40 CFR 80.92 - Baseline auditor requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Baseline auditor requirements. 80.92... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Anti-Dumping § 80.92 Baseline auditor requirements. (a... determination methodology, resulting baseline fuel parameter, volume and emissions values verified by an auditor...

  5. A baseline for the multivariate comparison of resting state networks

    Directory of Open Access Journals (Sweden)

    Elena A Allen

    2011-02-01

    Full Text Available As the size of functional and structural MRI datasets expands, it becomes increasingly important to establish a baseline from which diagnostic relevance may be determined, a processing strategy that efficiently prepares data for analysis, and a statistical approach that identifies important effects in a manner that is both robust and reproducible. In this paper, we introduce a multivariate analytic approach that optimizes sensitivity and reduces unnecessary testing. We demonstrate the utility of this mega-analytic approach by identifying the effects of age and gender on the resting state networks of 603 healthy adolescents and adults (mean age: 23.4 years, range: 12 to 71 years. Data were collected on the same scanner, preprocessed using an automated analysis pipeline based in SPM, and studied using group independent component analysis. Resting state networks were identified and evaluated in terms of three primary outcome measures: time course spectral power, spatial map intensity, and functional network connectivity. Results revealed robust effects of age on all three outcome measures, largely indicating decreases in network coherence and connectivity with increasing age. Gender effects were of smaller magnitude but suggested stronger intra-network connectivity in females and more inter-network connectivity in males, particularly with regard to sensorimotor networks. These findings, along with the analysis approach and statistical framework described here, provide a useful baseline for future investigations of brain networks in health and disease.

  6. Baseline metal concentrations in Paramoera walkeri from East Antarctica

    International Nuclear Information System (INIS)

    Palmer, Anne S. . E-mail Anne.Palmer@utas.edu.au; Snape, Ian; Stark, Jonathan S.; Johnstone, Glenn J.; Townsend, Ashley T.

    2006-01-01

    Remediation of the Thala Valley waste disposal site near Casey Station, East Antarctica was conducted in the austral summer of 2003/2004. Biomonitoring of the adjacent marine environment was undertaken using the gammaridean amphipod Paramoera walkeri as a sentinel species [Stark, J.S., Johnstone, G.J., Palmer, A.S., Snape, I., Larner, B.L., Riddle, M.J., in press, doi:10.1016/j.marpolbul.2006.05.020. Monitoring the remediation of a near shore waste disposal site in Antarctica using the amphipod Paramoera walkeri and diffusive gradients in thin films (DGTs). Marine Pollution Bulletin and references therein]. Determination of uptake of metals and hypothesis testing for differences that could be attributed to contamination required the establishment of baseline metal concentrations in P. walkeri. Baseline metal concentrations from two reference locations in the Windmill Islands are presented here. P. walkeri was a found to be a sensitive bioaccumulating organism that recorded spatial and temporal variability at the reference sites. Measurement of metals in P. walkeri required the development of a simple digestion procedure that used concentrated nitric acid. For the first time, rare earth metals were determined with additional clean procedures required to measure ultra low concentrations using magnetic sector ICP-MS. Certified and in-house reference materials were employed to ensure method reliability

  7. U Plant Aggregate Area Management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document was prepared in support of an Aggregate Area Management Study of U Plant. It provides a technical baseline of the aggregate area and results from an environmental investigation that was undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC), which is currently the Waste Site and Facility Research Office, Natural Resources, Bechtel Hanford, Inc. (BHI). It is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. U Plant refers to the 221-U Process Canyon Building, a chemical separation facility constructed during World War II. It also includes the Uranium Oxide (UO 3 ) Plant constructed at the same time as 221-U as an adjunct to the original plutonium separation process but which, like 221-U, was converted for other missions. Waste sites are associated primarily with U Plant's 1952 through 1958 Uranium Metal Recovery Program mission and the U0 3 Plant's ongoing U0 3 mission. Waste sites include cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, a waste vault, and the lines and encasements that connect them. It also includes the U Pond and its feed ditches and an underground tank farm designed for high-level liquid wastes

  8. Gravity sensing using Very Long Baseline Atom Interferometry

    Science.gov (United States)

    Schlippert, D.; Wodey, E.; Meiners, C.; Tell, D.; Schubert, C.; Ertmer, W.; Rasel, E. M.

    2017-12-01

    Very Long Baseline Atom Interferometry (VLBAI) has applications in high-accuracy absolute gravimetry, gravity-gradiometry, and for tests of fundamental physics. Thanks to the quadratic scaling of the phase shift with increasing free evolution time, extending the baseline of atomic gravimeters from tens of centimeters to meters puts resolutions of 10-13g and beyond in reach.We present the design and progress of key elements of the VLBAI-test stand: a dual-species source of Rb and Yb, a high-performance two-layer magnetic shield, and an active vibration isolation system allowing for unprecedented stability of the mirror acting as an inertial reference. We envisage a vibration-limited short-term sensitivity to gravitational acceleration of 1x10-8 m/s-2Hz-1/2 and up to a factor of 25 improvement when including additional correlation with a broadband seismometer. Here, the supreme long-term stability of atomic gravity sensors opens the route towards competition with superconducting gravimeters. The operation of VLBAI as a differential dual-species gravimeter using ultracold mixtures of Yb and Rb atoms enables quantum tests of the universality of free fall (UFF) at an unprecedented level of <10-13, potentially surpassing the best experiments to date.

  9. Elevating Baseline Activation Does Not Facilitate Reading of Unattended Words

    Science.gov (United States)

    Lien, Mei-Ching; Kouchi, Scott; Ruthruff, Eric; Lachter, Joel B.

    2009-01-01

    Previous studies have disagreed the extent to which people extract meaning from words presented outside the focus of spatial attention. The present study, examined a possible explanation for such discrepancies, inspired by attenuation theory: unattended words can be read more automatically when they have a high baseline level of activation (e.g., due to frequent repetition or due to being expected in a given context). We presented a brief prime word in lowercase, followed by a target word in uppercase. Participants indicated whether the target word belonged to a particular category (e.g., "sport"). When we drew attention to the prime word using a visual cue, the prime produced substantial priming effects on target responses (i.e., faster responses when the prime and target words were identical or from the same category than when they belonged to different categories). When prime words were not attended, however, they produced no priming effects. This finding replicated even when there were only 4 words, each repeated 160 times during the experiment. Even with a very high baseline level of activation, it appears that very little word processing is possible without spatial attention.

  10. DGEMP-OE (2008) Energy Baseline Scenario. Synthesis report

    International Nuclear Information System (INIS)

    2008-01-01

    A 'Business as usual' or 'Baseline' scenario of energy trends to 2020-2030 is produced by France every four years, as requested by the International Energy Agency in order to update the global scenarios published in its World Energy Outlook. Since the most recent scenario of this type was drawn up in 2003-2004, the time has come to renew the effort for the IEA's next in-depth review of French energy policy. Specifically, the DGEMP seeks to predict the future of France's energy situation assuming that no policies or new measures are taken affecting (i.e. improving or deteriorating) the situation other than those already in place or adopted as of 1 January 2008 (in other words, before measures such as those stemming from the Grenelle Environment Forum). On the other hand, it is assumed that change in the energy system is guided by 'conventional wisdom' according to which political options and behaviours by economic units are expected to be 'reasonable'. As a result, even should its projections prove inappropriate, this cannot be considered a 'worst-case' scenario. Indeed, beyond the IEA, this scenario can be used to establish an MEA (Multilateral Environment Agreement) scenario (based on existing measures) for national communications submitted under the U.N. Climate Convention. The scenarios by the 'Energy' Commission, part of the Centre d'Analyse Strategique (CAS), could have been used, particularly since the consultant who worked with the CAS to develop its scenarios was also commissioned by the DGEMP. However, several considerations argued in favour of proceeding separately: - The CAS scenarios drew on the DGEMP's 2004 baseline scenario, even though certain parameters were updated (in particular energy prices). - Moreover, the concept underpinning the DGEMP baseline scenario is that it should to every extent possible remain constant over time to secure continued consensus on this 'reference' at national level. - Finally, the MEDEE energy demand model applied in

  11. Physics with a very long neutrino factory baseline

    International Nuclear Information System (INIS)

    Gandhi, Raj; Winter, Walter

    2007-01-01

    We discuss the neutrino oscillation physics of a very long neutrino factory baseline over a broad range of lengths (between 6000 km and 9000 km), centered on the 'magic baseline' (∼7500 km) where correlations with the leptonic CP phase are suppressed by matter effects. Since the magic baseline depends only on the density, we study the impact of matter density profile effects and density uncertainties over this range, and the impact of detector locations off the optimal baseline. We find that the optimal constant density describing the physics over this entire baseline range is about 5% higher than the average matter density. This implies that the magic baseline is significantly shorter than previously inferred. However, while a single detector optimization requires fine-tuning of the (very long) baseline length, its combination with a near detector at a shorter baseline is much less sensitive to the far detector location and to uncertainties in the matter density. In addition, we point out different applications of this baseline which go beyond its excellent correlation and degeneracy resolution potential. We demonstrate that such a long baseline assists in the improvement of the θ 13 precision and in the resolution of the octant degeneracy. Moreover, we show that the neutrino data from such a baseline could be used to extract the matter density along the profile up to 0.24% at 1σ for large sin 2 2θ 13 , providing a useful discriminator between different geophysical models

  12. Intrafractional baseline drift during free breathing breast cancer radiation therapy.

    Science.gov (United States)

    Jensen, Christer Andre; Acosta Roa, Ana María; Lund, Jo-Åsmund; Frengen, Jomar

    2017-06-01

    Intrafraction motion in breast cancer radiation therapy (BCRT) has not yet been thoroughly described in the literature. It has been observed that baseline drift occurs as part of the intrafraction motion. This study aims to measure baseline drift and its incidence in free-breathing BCRT patients using an in-house developed laser system for tracking the position of the sternum. Baseline drift was monitored in 20 right-sided breast cancer patients receiving free breathing 3D-conformal RT by using an in-house developed laser system which measures one-dimensional distance in the AP direction. A total of 357 patient respiratory traces from treatment sessions were logged and analysed. Baseline drift was compared to patient positioning error measured from in-field portal imaging. The mean overall baseline drift at end of treatment sessions was -1.3 mm for the patient population. Relatively small baseline drift was observed during the first fraction; however it was clearly detected already at the second fraction. Over 90% of the baseline drift occurs during the first 3 min of each treatment session. The baseline drift rate for the population was -0.5 ± 0.2 mm/min in the posterior direction the first minute after localization. Only 4% of the treatment sessions had a 5 mm or larger baseline drift at 5 min, all towards the posterior direction. Mean baseline drift in the posterior direction in free breathing BCRT was observed in 18 of 20 patients over all treatment sessions. This study shows that there is a substantial baseline drift in free breathing BCRT patients. No clear baseline drift was observed during the first treatment session; however, baseline drift was markedly present at the rest of the sessions. Intrafraction motion due to baseline drift should be accounted for in margin calculations.

  13. Very Long Baseline Interferometry: Dependencies on Frequency Stability

    Science.gov (United States)

    Nothnagel, Axel; Nilsson, Tobias; Schuh, Harald

    2018-04-01

    Very Long Baseline Interferometry (VLBI) is a differential technique observing radiation of compact extra-galactic radio sources with pairs of radio telescopes. For these observations, the frequency standards at the telescopes need to have very high stability. In this article we discuss why this is, and we investigate exactly how precise the frequency standards need to be. Four areas where good clock performance is needed are considered: coherence, geodetic parameter estimation, correlator synchronization, and UT1 determination. We show that in order to ensure the highest accuracy of VLBI, stability similar to that of a hydrogen maser is needed for time-scales up to a few hours. In the article, we are considering both traditional VLBI where extra-galactic radio sources are observed, as well as observation of man-made artificial radio sources emitted by satellites or spacecrafts.

  14. Baselines and test data for cross-lingual inference

    DEFF Research Database (Denmark)

    Agic, Zeljko; Schluter, Natalie

    2018-01-01

    The recent years have seen a revival of interest in textual entailment, sparked by i) the emergence of powerful deep neural network learners for natural language processing and ii) the timely development of large-scale evaluation datasets such as SNLI. Recast as natural language inference......, the problem now amounts to detecting the relation between pairs of statements: they either contradict or entail one another, or they are mutually neutral. Current research in natural language inference is effectively exclusive to English. In this paper, we propose to advance the research in SNLI-style natural...... language inference toward multilingual evaluation. To that end, we provide test data for four major languages: Arabic, French, Spanish, and Russian. We experiment with a set of baselines. Our systems are based on cross-lingual word embeddings and machine translation. While our best system scores an average...

  15. 1st DeepWind 5 MW Baseline design

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Vita, Luca; Aagaard Madsen, Helge

    2012-01-01

    The first 5MW baseline design of the DeepWind concept is presented for a Darrieus type floating wind turbine system for water depths of more than 150 m. This design will be used as design reference to test the next technological improvements of sub-component level, being based as much as possible...... trajectory on the water plane. The generator is placed at the bottom of the platform and uses 5MW direct drive technology.The conceptual design is evaluated with numerical simulations in the time domain using the aero-elastic code HAWC2. In order to investigate the concept, a double-disc blade element....... A site has been chosen for the floating turbine off Norway as representative for external conditions. The structure is verified according to an ultimate strength analysis, including loads from wind, waves and currents. The stability of the platform is investigated, considering the displacements...

  16. Determination of the Territorial Sea Baseline - Measurement Aspect

    Science.gov (United States)

    Specht, Cezary; Weintrit, Adam; Specht, Mariusz; Dabrowski, Pawel

    2017-12-01

    Determining the course of the territorial sea baseline (TSB) of the coastal state is the basis for establishing its maritime boundaries, thus becoming indirect part of maritime policy of the state. Besides the following aspects: legal and methodological as described in the conventions, acts, standards and regulations, equally important is the issue of measurement methodology with respect to the boundaries of the territorial sea. The publication discussed accuracy requirements of the TSB measurement implementation, the relationship of sea level with a choice of the method of its determination, and discussed the implementation of such a measurement on a selected example. As the test reservoir was used the 400-meter stretch of the public beach in Gdynia. During the measurements they used the GNSS geodetic receiver operating in real time based on the geodetic network - VRSnet.pl. Additionally, a comparison was made of the applied method with analogous measurements of the TSB performed in 1999.

  17. Long baseline Super-Beam experiments in Europe within LAGUNA

    CERN Document Server

    Coloma, Pilar; Pascoli, Silvia

    2011-01-01

    We explore the physics reach of several possible configurations for a Super-Beam experiment in Europe, focusing on the possibilities of discovering $\\theta_{13}$, CP violation in the leptonic sector and the ordering of neutrino mass eigenstates. We consider the three different detector technologies: Water \\v{C}erenkov, Liquid Argon and Liquid Scintillator, and seven possible sites in Europe which would be able to host such a detector underground. The distances to these sites from CERN, where the beam would be originated, go from 130 km to 2300 km. The neutrino flux is optimized in each case as to match the first oscillation peak for each of the baselines under consideration. We also study the impact of several experimental factors in the performance of each detector technology. These include the reconstruction efficiencies for quasi-elastic events, the rejection efficiencies for the neutral-current backgrounds, the ratio between running times in neutrino and antineutrino modes and the systematic uncertainties...

  18. Baseline distortion effect on gamma-ray pulse-height spectra in neutron capture experiments

    International Nuclear Information System (INIS)

    Laptev, A.; Harada, H.; Nakamura, S.; Hori, J.; Igashira, M.; Ohsaki, T.; Ohgama, K.

    2005-01-01

    A baseline distortion effect due to gamma-flash at neutron time-of-flight measurement using a pulse neutron source has been investigated. Pulses from C 6 D 6 detectors accumulated by flash-ADC were processed with both standard analog-to-digital converter (ADC) and flash-ADC operational modes. A correction factor of gamma-ray yields, due to baseline shift, was quantitatively obtained by comparing the pulse height spectra of the two data-taking modes. The magnitude of the correction factor depends on the time after gamma-flash and has complex time dependence with a changing sign

  19. Spent Nuclear Fuel Project technical baseline document. Fiscal year 1995: Volume 1, Baseline description

    International Nuclear Information System (INIS)

    Womack, J.C.; Cramond, R.; Paedon, R.J.

    1995-01-01

    This document is a revision to WHC-SD-SNF-SD-002, and is issued to support the individual projects that make up the Spent Nuclear Fuel Project in the lower-tier functions, requirements, interfaces, and technical baseline items. It presents results of engineering analyses since Sept. 1994. The mission of the SNFP on the Hanford site is to provide safety, economic, environmentally sound management of Hanford SNF in a manner that stages it to final disposition. This particularly involves K Basin fuel, although other SNF is involved also

  20. Mechanical Thrombectomy in Elderly Stroke Patients with Mild-to-Moderate Baseline Disability.

    Science.gov (United States)

    Slawski, Diana E; Salahuddin, Hisham; Shawver, Julie; Kenmuir, Cynthia L; Tietjen, Gretchen E; Korsnack, Andrea; Zaidi, Syed F; Jumaa, Mouhammad A

    2018-04-01

    The number of elderly patients suffering from ischemic stroke is rising. Randomized trials of mechanical thrombectomy (MT) generally exclude patients over the age of 80 years with baseline disability. The aim of this study was to understand the efficacy and safety of MT in elderly patients, many of whom may have baseline impairment. Between January 2015 and April 2017, 96 patients ≥80 years old who underwent MT for stroke were selected for a chart review. The data included baseline characteristics, time to treatment, the rate of revascularization, procedural complications, mortality, and 90-day good outcome defined as a modified Rankin Scale (mRS) score of 0-2 or return to baseline. Of the 96 patients, 50 had mild baseline disability (mRS score 0-1) and 46 had moderate disability (mRS score 2-4). Recanalization was achieved in 84% of the patients, and the rate of symptomatic hemorrhage was 6%. At 90 days, 34% of the patients had a good outcome. There were no significant differences in good outcome between those with mild and those with moderate baseline disability (43 vs. 24%, p = 0.08), between those aged ≤85 and those aged > 85 years (40.8 vs. 26.1%, p = 0.19), and between those treated within and those treated beyond 8 h (39 vs. 20%, p = 0.1). The mortality rate was 38.5% at 90 days. The Alberta Stroke Program Early CT Score (ASPECTS) and the National Institutes of Health Stroke Scale (NIHSS) predicted good outcome regardless of baseline disability ( p baseline disability, and delayed treatment are associated with sub-optimal outcomes after MT. However, redefining good outcome to include return to baseline functioning demonstrates that one-third of this patient population benefits from MT, suggesting the real-life utility of this treatment.

  1. An Improved Rank Correlation Effect Size Statistic for Single-Case Designs: Baseline Corrected Tau.

    Science.gov (United States)

    Tarlow, Kevin R

    2017-07-01

    Measuring treatment effects when an individual's pretreatment performance is improving poses a challenge for single-case experimental designs. It may be difficult to determine whether improvement is due to the treatment or due to the preexisting baseline trend. Tau- U is a popular single-case effect size statistic that purports to control for baseline trend. However, despite its strengths, Tau- U has substantial limitations: Its values are inflated and not bound between -1 and +1, it cannot be visually graphed, and its relatively weak method of trend control leads to unacceptable levels of Type I error wherein ineffective treatments appear effective. An improved effect size statistic based on rank correlation and robust regression, Baseline Corrected Tau, is proposed and field-tested with both published and simulated single-case time series. A web-based calculator for Baseline Corrected Tau is also introduced for use by single-case investigators.

  2. Single-baseline RTK GNSS Positioning for Hydrographic Surveying

    Science.gov (United States)

    Metin Alkan, Reha; Murat Ozulu, I.; Ilçi, Veli; Kahveci, Muzaffer

    2015-04-01

    Positioning with GNSS technique can be carried out in two ways, absolute and relative. It has been possible to reach a few meters absolute point positioning accuracies in real time after disabling SA permanently in May 2000. Today, accuracies obtainable from absolute point positioning using code observations are not sufficient for most surveying applications. Thus to meet higher accuracy requirements, differential methods using single or dual frequency geodetic-grade GNSS receivers that measure carrier phase have to be used. However, this method requires time-cost field and office works and if the measurement is not carried out with conventional RTK method, user needs a GNSS data processing software to estimate the coordinates. If RTK is used, at least two or more GNSS receivers are required, one as a reference and the other as a rover. Moreover, the distance between the receivers must not exceed 15-20 km in order to be able to rapidly and reliably resolve the carrier phase ambiguities. On the other hand, based on the innovations and improvements in satellite geodesy and GNSS modernization studies occurred within the last decade, many new positioning methods and new approaches have been developed. One of them is Network-RTK (or commonly known as CORS) and the other is Single-baseline RTK. These methods are widely used for many surveying applications in many countries. The user of the system can obtain his/her position within a few cm level of accuracy in real-time with only a single GNSS receiver that has Network RTK (CORS) capability. When compared with the conventional differential and RTK methods, this technique has several significant advantages as it is easy to use and it produces accurate, cost-effective and rapid solutions. In Turkey, establishment of a multi-base RTK network was completed and opened for civilian use in 2009. This network is called CORS-TR and consists of 146 reference stations having about 80-100 km interstation distances. It is possible

  3. Geodesy by radio interferometry - Determinations of baseline vector, earth rotation, and solid earth tide parameters with the Mark I very long baseline radio interferometery system

    Science.gov (United States)

    Ryan, J. W.; Clark, T. A.; Coates, R. J.; Ma, C.; Wildes, W. T.

    1986-01-01

    Thirty-seven very long baseline radio interferometry experiments performed between 1972 and 1978 are analyzed and estimates of baseline vectors between six sites, five in the continental United States and one in Europe are derived. No evidence of significant changes in baseline length is found. For example, with a statistical level of confidence of approximately 85 percent, upper bounds on such changes within the United States ranged from a low of 10 mm/yr for the 850 km baseline between Westford, Massachusetts, and Green Bank, West Virginia, to a high of 90 mm/yr for the nearly 4000 km baseline between Westford and Goldstone, California. Estimates for universal time and for the x component of the position of the earth's pole are obtained. For the last 15 experiments, the only ones employing wideband receivers, the root-mean-square differences between the derived values and the corresponding ones published by the Bureau International de l'Heure are 0.0012 s and 0.018 arc sec respectively. The average value obtained for the radial Love number for the solid earth is 0.62 + or - 0.02 (estimated standard error).

  4. Baseline Q waves as a prognostic modulator in patients with ST-segment elevation: insights from the PLATO trial.

    Science.gov (United States)

    Siha, Hany; Das, Debraj; Fu, Yuling; Zheng, Yinggan; Westerhout, Cynthia M; Storey, Robert F; James, Stefan; Wallentin, Lars; Armstrong, Paul W

    2012-07-10

    Baseline Q waves may provide additional value compared with time from the onset of symptoms in predicting outcomes for patients with ST-segment elevation. We evaluated whether baseline Q waves superseded time from symptom onset as a prognostic marker of one-year mortality in patients with ST-segment elevation acute coronary syndrome. Our study was derived from data from patients undergoing primary percutaneous coronary intervention within 24 hours in the PLATelet inhibition and patient Outcomes trial Q waves on the baseline electrocardiogram were evaluated by a blinded core laboratory. We assessed the associations between baseline Q waves and time from symptom onset to percutaneous coronary intervention with peak biomarkers, ST-segment resolution on the discharge electrocardiogram, and one-year all-cause and vascular mortality. Of 4341 patients with ST-segment elevation, 46% had baseline Q waves. Compared to those without Q waves, those with baseline Q waves were older, more frequently male, had higher heart rates, more advanced Killip class and had a longer time between the onset of symptoms and percutaneous coronary intervention. They also had higher one-year all-cause mortality than patients without baseline Q waves (baseline Q waves: 4.9%; no baseline Q waves: 2.8%; hazard ratio [HR] 1.78, 95% confidence interval [CI] 1.29-2.45, p waves. After multivariable adjustment, baseline Q waves, but not time from symptom onset, were associated with a significant increase in all-cause mortality (adjusted HR 1.42, 95% CI 1.10-2.01, p = 0.046) and vascular mortality (adjusted HR 1.58, 95% CI 1.09-2.28, p = 0.02). The presence of baseline Q waves provides useful additional prognostic insight into the clinical outcome of patients with ST-segment elevation. Clinical Trials.gov registration no. NCT00391872.

  5. Large short-baseline νμ disappearance

    International Nuclear Information System (INIS)

    Giunti, Carlo; Laveder, Marco

    2011-01-01

    We analyze the LSND, KARMEN, and MiniBooNE data on short-baseline ν μ →ν e oscillations and the data on short-baseline ν e disappearance obtained in the Bugey-3 and CHOOZ reactor experiments in the framework of 3+1 antineutrino mixing, taking into account the MINOS observation of long-baseline ν μ disappearance and the KamLAND observation of very-long-baseline ν e disappearance. We show that the fit of the data implies that the short-baseline disappearance of ν μ is relatively large. We obtain a prediction of an effective amplitude sin 2 2θ μμ > or approx. 0.1 for short-baseline ν μ disappearance generated by 0.2 2 2 , which could be measured in future experiments.

  6. Raise your defence: a baseline for security

    CERN Multimedia

    Computer Security Team

    2011-01-01

    It is an unfair imbalance: the (computer) security of a system/service is only as strong as the weakest link in the chain of protection. This provides attackers with an incredible advantage: they can choose when to attack, where and with which means. The defence side is permanently under pressure: they must defend at all times all assets against all eventualities. For computer security, this means that every computer system, every account, every web site and every service must be properly protected --- always.   In particular, at CERN, those services visible to the Internet are permanently probed. Web sites and servers are permanently scanned by adversaries for vulnerabilities; attackers repeatedly try to guess user passwords on our remote access gateways like LXPLUS or CERNTS; computing services, e.g. for Grid computing, are analysed again and again by malicious attackers for weaknesses which can be exploited. Thanks to the vigilance of the corresponding system and service experts, these atta...

  7. Functional Foods Baseline and Requirements Analysis

    Science.gov (United States)

    Cooper, M. R.; Bermudez-Aguirre, L. D.; Douglas, G.

    2015-01-01

    Current spaceflight foods were evaluated to determine if their nutrient profile supports positioning as a functional food and if the stability of the bioactive compound within the food matrix over an extended shelf-life correlated with the expected storage duration during the mission. Specifically, the research aims were: Aim A. To determine the amount of each nutrient in representative spaceflight foods immediately after processing and at predetermined storage time to establish the current nutritional state. Aim B. To identify the requirements to develop foods that stabilize these nutrients such that required concentrations are maintained in the space food system throughout long duration missions (up to five years). Aim C. To coordinate collaborations with health and performance groups that may require functional foods as a countermeasure.

  8. Baseline inventory data recommendations for National Wildlife Refuges

    Data.gov (United States)

    Department of the Interior — The Baseline Inventory Team recommends that each refuge have available abiotic “data layers” for topography, aerial photography, hydrography, soils, boundaries, and...

  9. Site Outcomes Baseline Multi Year Work Plan Volume 1, River Corridor Restoration Baseline

    International Nuclear Information System (INIS)

    Wintczak, T.M.

    2001-01-01

    The River Corridor Restoration volume is a compilation of Hanford Site scope, which excludes the approximately 194 km 2 Central Plateau. The River Corridor scope is currently contractually assigned to Fluor Hanford, Bechtel Hanford, inc., DynCorp, and Pacific Northwest National Laboratory, and others. The purpose of this project specification is to provide an overall scoping document for the River Corridor Restoration volume, and to provide a link with the overall Hanford Site River Corridor scope. Additionally, this specification provides an integrated and consolidated source of information for the various scopes, by current contract, for the River Corridor Restoration Baseline. It identifies the vision, mission, and goals, as well as the operational history of the Hanford Site, along with environmental setting and hazards

  10. Baseline Tumor Lipiodol Uptake after Transarterial Chemoembolization for Hepatocellular Carcinoma: Identification of a Threshold Value Predicting Tumor Recurrence.

    Science.gov (United States)

    Matsui, Yusuke; Horikawa, Masahiro; Jahangiri Noudeh, Younes; Kaufman, John A; Kolbeck, Kenneth J; Farsad, Khashayar

    2017-12-01

    The aim of the study was to evaluate the association between baseline Lipiodol uptake in hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) with early tumor recurrence, and to identify a threshold baseline uptake value predicting tumor response. A single-institution retrospective database of HCC treated with Lipiodol-TACE was reviewed. Forty-six tumors in 30 patients treated with a Lipiodol-chemotherapy emulsion and no additional particle embolization were included. Baseline Lipiodol uptake was measured as the mean Hounsfield units (HU) on a CT within one week after TACE. Washout rate was calculated dividing the difference in HU between the baseline CT and follow-up CT by time (HU/month). Cox proportional hazard models were used to correlate baseline Lipiodol uptake and other variables with tumor response. A receiver operating characteristic (ROC) curve was used to identify the optimal threshold for baseline Lipiodol uptake predicting tumor response. During the follow-up period (mean 5.6 months), 19 (41.3%) tumors recurred (mean time to recurrence = 3.6 months). In a multivariate model, low baseline Lipiodol uptake and higher washout rate were significant predictors of early tumor recurrence ( P = 0.001 and Baseline Lipiodol uptake and washout rate on follow-up were independent predictors of early tumor recurrence. A threshold value of baseline Lipiodol uptake > 270.2 HU was highly sensitive and specific for tumor response. These findings may prove useful for determining subsequent treatment strategies after Lipiodol TACE.

  11. Informed baseline subtraction of proteomic mass spectrometry data aided by a novel sliding window algorithm.

    Science.gov (United States)

    Stanford, Tyman E; Bagley, Christopher J; Solomon, Patty J

    2016-01-01

    Proteomic matrix-assisted laser desorption/ionisation (MALDI) linear time-of-flight (TOF) mass spectrometry (MS) may be used to produce protein profiles from biological samples with the aim of discovering biomarkers for disease. However, the raw protein profiles suffer from several sources of bias or systematic variation which need to be removed via pre-processing before meaningful downstream analysis of the data can be undertaken. Baseline subtraction, an early pre-processing step that removes the non-peptide signal from the spectra, is complicated by the following: (i) each spectrum has, on average, wider peaks for peptides with higher mass-to-charge ratios ( m / z ), and (ii) the time-consuming and error-prone trial-and-error process for optimising the baseline subtraction input arguments. With reference to the aforementioned complications, we present an automated pipeline that includes (i) a novel 'continuous' line segment algorithm that efficiently operates over data with a transformed m / z -axis to remove the relationship between peptide mass and peak width, and (ii) an input-free algorithm to estimate peak widths on the transformed m / z scale. The automated baseline subtraction method was deployed on six publicly available proteomic MS datasets using six different m/z-axis transformations. Optimality of the automated baseline subtraction pipeline was assessed quantitatively using the mean absolute scaled error (MASE) when compared to a gold-standard baseline subtracted signal. Several of the transformations investigated were able to reduce, if not entirely remove, the peak width and peak location relationship resulting in near-optimal baseline subtraction using the automated pipeline. The proposed novel 'continuous' line segment algorithm is shown to far outperform naive sliding window algorithms with regard to the computational time required. The improvement in computational time was at least four-fold on real MALDI TOF-MS data and at least an order of

  12. Business-as-Unusual: Existing policies in energy model baselines

    International Nuclear Information System (INIS)

    Strachan, Neil

    2011-01-01

    Baselines are generally accepted as a key input assumption in long-term energy modelling, but energy models have traditionally been poor on identifying baselines assumptions. Notably, transparency on the current policy content of model baselines is now especially critical as long-term climate mitigation policies have been underway for a number of years. This paper argues that the range of existing energy and emissions policies are an integral part of any long-term baseline, and hence already represent a 'with-policy' baseline, termed here a Business-as-Unusual (BAuU). Crucially, existing energy policies are not a sunk effort; as impacts of existing policy initiatives are targeted at future years, they may be revised through iterative policy making, and their quantitative effectiveness requires ex-post verification. To assess the long-term role of existing policies in energy modelling, currently identified UK policies are explicitly stripped out of the UK MARKAL Elastic Demand (MED) optimisation energy system model, to generate a BAuU (with-policy) and a REF (without policy) baseline. In terms of long-term mitigation costs, policy-baseline assumptions are comparable to another key exogenous modelling assumption - that of global fossil fuel prices. Therefore, best practice in energy modelling would be to have both a no-policy reference baseline, and a current policy reference baseline (BAuU). At a minimum, energy modelling studies should have a transparent assessment of the current policy contained within the baseline. Clearly identifying and comparing policy-baseline assumptions are required for cost effective and objective policy making, otherwise energy models will underestimate the true cost of long-term emissions reductions.

  13. Esophageal Baseline Impedance Reflects Mucosal Integrity and Predicts Symptomatic Outcome With Proton Pump Inhibitor Treatment.

    Science.gov (United States)

    Xie, Chenxi; Sifrim, Daniel; Li, Yuwen; Chen, Minhu; Xiao, Yinglian

    2018-01-30

    Esophageal baseline impedance, which is decreased in gastroesophageal reflux disease (GERD) patients, is related to the severity of acid reflux and the integrity of the esophageal mucosa. The study aims to compare the baseline impedance and the dilated intercellular spaces (DIS) within patients with typical reflux symptoms and to evaluate the correlation of baseline impedance with DIS, esophageal acid exposure, as well as the efficacy of proton pump inhibitor (PPI) treatment. Ninety-two patients and 10 healthy controls were included in the study. Erosive esophagitis (EE) was defined by esophageal mucosal erosion under upper endoscopy. Patients without mucosa erosion were divided into groups with pathologic acid reflux (non-erosive reflux disease [NERD]) or with hypersensitive esophagus. The biopsies of esophageal mucosa were taken 2-4 cm above the gastroesophageal junction Z-line during upper endoscopy for DIS measurement. All the patients received esomeprazole 20 mg twice-daily treatment for 8 weeks. The efficacy of esomeprazole was evaluated among all patients. The intercellular spaces were dilated in both EE and NERD patients ( P baseline impedance was decreased in both EE patients and NERD patients, and negatively correlated to the acid exposure time ( r = -0.527, P baseline impedance ( r = -0.230, P Baseline impedance > 1764 Ω" was an independent predictor for PPI failure (OR, 11.9; 95% CI, 2.4-58.9; P baseline impedance was observed in patients with mucosa erosion or pathological acid reflux. The baseline impedance reflected the mucosal integrity, it was more sensitive to esophageal acid exposure. Patients with high impedance might not benefit from the PPI treatment.

  14. Local Stressors, Resilience, and Shifting Baselines on Coral Reefs.

    Science.gov (United States)

    McLean, Matthew; Cuetos-Bueno, Javier; Nedlic, Osamu; Luckymiss, Marston; Houk, Peter

    2016-01-01

    Understanding how and why coral reefs have changed over the last twenty to thirty years is crucial for sustaining coral-reef resilience. We used a historical baseline from Kosrae, a typical small island in Micronesia, to examine changes in fish and coral assemblages since 1986. We found that natural gradients in the spatial distribution of fish and coral assemblages have become amplified, as island geography is now a stronger determinant of species abundance patterns, and habitat forming Acropora corals and large-bodied fishes that were once common on the leeward side of the island have become scarce. A proxy for fishing access best predicted the relative change in fish assemblage condition over time, and in turn, declining fish condition was the only factor correlated with declining coral condition, suggesting overfishing may have reduced ecosystem resilience. Additionally, a proxy for watershed pollution predicted modern coral assemblage condition, suggesting pollution is also reducing resilience in densely populated areas. Altogether, it appears that unsustainable fishing reduced ecosystem resilience, as fish composition has shifted to smaller species in lower trophic levels, driven by losses of large predators and herbivores. While prior literature and anecdotal reports indicate that major disturbance events have been rare in Kosrae, small localized disturbances coupled with reduced resilience may have slowly degraded reef condition through time. Improving coral-reef resilience in the face of climate change will therefore require improved understanding and management of growing artisanal fishing pressure and watershed pollution.

  15. Local Stressors, Resilience, and Shifting Baselines on Coral Reefs.

    Directory of Open Access Journals (Sweden)

    Matthew McLean

    Full Text Available Understanding how and why coral reefs have changed over the last twenty to thirty years is crucial for sustaining coral-reef resilience. We used a historical baseline from Kosrae, a typical small island in Micronesia, to examine changes in fish and coral assemblages since 1986. We found that natural gradients in the spatial distribution of fish and coral assemblages have become amplified, as island geography is now a stronger determinant of species abundance patterns, and habitat forming Acropora corals and large-bodied fishes that were once common on the leeward side of the island have become scarce. A proxy for fishing access best predicted the relative change in fish assemblage condition over time, and in turn, declining fish condition was the only factor correlated with declining coral condition, suggesting overfishing may have reduced ecosystem resilience. Additionally, a proxy for watershed pollution predicted modern coral assemblage condition, suggesting pollution is also reducing resilience in densely populated areas. Altogether, it appears that unsustainable fishing reduced ecosystem resilience, as fish composition has shifted to smaller species in lower trophic levels, driven by losses of large predators and herbivores. While prior literature and anecdotal reports indicate that major disturbance events have been rare in Kosrae, small localized disturbances coupled with reduced resilience may have slowly degraded reef condition through time. Improving coral-reef resilience in the face of climate change will therefore require improved understanding and management of growing artisanal fishing pressure and watershed pollution.

  16. Scientific Opportunities with the Long-Baseline Neutrino Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Adams, C.; et al.

    2013-07-28

    In this document, we describe the wealth of science opportunities and capabilities of LBNE, the Long-Baseline Neutrino Experiment. LBNE has been developed to provide a unique and compelling program for the exploration of key questions at the forefront of particle physics. Chief among the discovery opportunities are observation of CP symmetry violation in neutrino mixing, resolution of the neutrino mass hierarchy, determination of maximal or near-maximal mixing in neutrinos, searches for nucleon decay signatures, and detailed studies of neutrino bursts from galactic supernovae. To fulfill these and other goals as a world-class facility, LBNE is conceived around four central components: (1) a new, intense wide-band neutrino source at Fermilab, (2) a fine-grained `near' neutrino detector just downstream of the source, (3) the Sanford Underground Research Facility (SURF) in Lead, South Dakota at an optimal distance (~1300 km) from the neutrino source, and (4) a massive liquid argon time-projection chamber (LArTPC) deployed there as a 'far' detector. The facilities envisioned are expected to enable many other science opportunities due to the high event rates and excellent detector resolution from beam neutrinos in the near detector and atmospheric neutrinos in the far detector. This is a mature, well developed, world class experiment whose relevance, importance, and probability of unearthing critical and exciting physics has increased with time.

  17. Study on the calibration and optimization of double theodolites baseline

    Science.gov (United States)

    Ma, Jing-yi; Ni, Jin-ping; Wu, Zhi-chao

    2018-01-01

    For the double theodolites measurement system baseline as the benchmark of the scale of the measurement system and affect the accuracy of the system, this paper puts forward a method for calibration and optimization of the double theodolites baseline. Using double theodolites to measure the known length of the reference ruler, and then reverse the baseline formula. Based on the error propagation law, the analyses show that the baseline error function is an important index to measure the accuracy of the system, and the reference ruler position, posture and so on have an impact on the baseline error. The optimization model is established and the baseline error function is used as the objective function, and optimizes the position and posture of the reference ruler. The simulation results show that the height of the reference ruler has no effect on the baseline error; the posture is not uniform; when the reference ruler is placed at x=500mm and y=1000mm in the measurement space, the baseline error is the smallest. The experimental results show that the experimental results are consistent with the theoretical analyses in the measurement space. In this paper, based on the study of the placement of the reference ruler, for improving the accuracy of the double theodolites measurement system has a reference value.

  18. 75 FR 30014 - Consumers Energy Company; Notice of Baseline Filing

    Science.gov (United States)

    2010-05-28

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-25-000] Consumers Energy Company; Notice of Baseline Filing May 21, 2010. Take notice that on May 17, 2010, Consumers Energy Company (Consumers) submitted a baseline filing of its Statement of Operating Conditions for the...

  19. 77 FR 31841 - Hope Gas, Inc.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-23-001] Hope Gas, Inc.; Notice of Baseline Filing Take notice that on May 16, 2012, Hope Gas, Inc. (Hope Gas) submitted a revised baseline filing of their Statement of Operating Conditions for services provided under Section 311 of the...

  20. 77 FR 26535 - Hope Gas, Inc.; Notice of Baseline Filing

    Science.gov (United States)

    2012-05-04

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-23-000] Hope Gas, Inc.; Notice of Baseline Filing Take notice that on April 26, 2012, Hope Gas, Inc. (Hope Gas) submitted a baseline filing of their Statement of Operating Conditions for services provided under Section 311 of the...

  1. Esophageal acid exposure decreases intraluminal baseline impedance levels

    NARCIS (Netherlands)

    Kessing, Boudewijn F.; Bredenoord, Albert J.; Weijenborg, Pim W.; Hemmink, Gerrit J. M.; Loots, Clara M.; Smout, A. J. P. M.

    2011-01-01

    Intraluminal baseline impedance levels are determined by the conductivity of the esophageal wall and can be decreased in gastroesophageal reflux disease (GERD) patients. The aim of this study was to investigate the baseline impedance in GERD patients, on and off proton pump inhibitor (PPI), and in

  2. Tank waste remediation system technical baseline summary description

    International Nuclear Information System (INIS)

    Raymond, R.E.

    1998-01-01

    This document is one of the tools used to develop and control the mission work as depicted in the included figure. This Technical Baseline Summary Description document is the top-level tool for management of the Technical Baseline for waste storage operations

  3. The Effect of Pretest Exercise on Baseline Computerized Neurocognitive Test Scores.

    Science.gov (United States)

    Pawlukiewicz, Alec; Yengo-Kahn, Aaron M; Solomon, Gary

    2017-10-01

    Baseline neurocognitive assessment plays a critical role in return-to-play decision making following sport-related concussions. Prior studies have assessed the effect of a variety of modifying factors on neurocognitive baseline test scores. However, relatively little investigation has been conducted regarding the effect of pretest exercise on baseline testing. The aim of our investigation was to determine the effect of pretest exercise on baseline Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores in adolescent and young adult athletes. We hypothesized that athletes undergoing self-reported strenuous exercise within 3 hours of baseline testing would perform more poorly on neurocognitive metrics and would report a greater number of symptoms than those who had not completed such exercise. Cross-sectional study; Level of evidence, 3. The ImPACT records of 18,245 adolescent and young adult athletes were retrospectively analyzed. After application of inclusion and exclusion criteria, participants were dichotomized into groups based on a positive (n = 664) or negative (n = 6609) self-reported history of strenuous exercise within 3 hours of the baseline test. Participants with a positive history of exercise were then randomly matched, based on age, sex, education level, concussion history, and hours of sleep prior to testing, on a 1:2 basis with individuals who had reported no pretest exercise. The baseline ImPACT composite scores of the 2 groups were then compared. Significant differences were observed for the ImPACT composite scores of verbal memory, visual memory, reaction time, and impulse control as well as for the total symptom score. No significant between-group difference was detected for the visual motor composite score. Furthermore, pretest exercise was associated with a significant increase in the overall frequency of invalid test results. Our results suggest a statistically significant difference in ImPACT composite scores between

  4. Vegetation Parameter Extraction Using Dual Baseline Polarimetric SAR Interferometry Data

    Science.gov (United States)

    Zhang, H.; Wang, C.; Chen, X.; Tang, Y.

    2009-04-01

    For vegetation parameter inversion, the single baseline polarimetric SAR interferometry (POLinSAR) technique, such as the three-stage method and the ESPRIT algorithm, is limited by the observed data with the minimum ground to volume amplitude ration, which effects the estimation of the effective phase center for the vegetation canopy or the surface, and thus results in the underestimated vegetation height. In order to remove this effect of the single baseline inversion techniques in some extend, another baseline POLinSAR data is added on vegetation parameter estimation in this paper, and a dual baseline POLinSAR technique for the extraction of the vegetation parameter is investigated and improved to reduce the dynamic bias for the vegetation parameter estimation. Finally, the simulated data and real data are used to validate this dual baseline technique.

  5. Baseline glucocorticoids are drivers of body mass gain in a diving seabird

    Science.gov (United States)

    Hennin, Holly; Berlin, Alicia; Love, Oliver P.

    2016-01-01

    Life-history trade-offs are influenced by variation in individual state, with individuals in better condition often completing life-history stages with greater success. Although resource accrual significantly impacts key life-history decisions such as the timing of reproduction, little is known about the underlying mechanisms driving resource accumulation. Baseline corticosterone (CORT, the primary avian glucocorticoid) mediates daily and seasonal energetics, responds to changes in food availability, and has been linked to foraging behavior, making it a strong potential driver of individual variation in resource accrual and deposition. Working with a captive colony of white-winged scoters (Melanitta fusca deglandi), we aimed to causally determine whether variation in baseline CORT drives individual body mass gains mediated through fattening rate (plasma triglycerides corrected for body mass). We implanted individuals with each of three treatment pellets to elevate CORT within a baseline range in a randomized order: control, low dose of CORT, high dose of CORT, then blood sampled and recorded body mass over a two-week period to track changes in baseline CORT, body mass, and fattening rates. The high CORT treatment significantly elevated levels of plasma hormone for a short period of time within the biologically relevant, baseline range for this species, but importantly did not inhibit the function of the HPA (hypothalamic–pituitary–adrenal) axis. Furthermore, an elevation in baseline CORT resulted in a consistent increase in body mass throughout the trial period compared to controls. This is some of the first empirical evidence demonstrating that elevations of baseline CORT within a biologically relevant range have a causal, direct, and positive influence on changes in body mass.

  6. Baseline glucocorticoids are drivers of body mass gain in a diving seabird.

    Science.gov (United States)

    Hennin, Holly L; Wells-Berlin, Alicia M; Love, Oliver P

    2016-03-01

    Life-history trade-offs are influenced by variation in individual state, with individuals in better condition often completing life-history stages with greater success. Although resource accrual significantly impacts key life-history decisions such as the timing of reproduction, little is known about the underlying mechanisms driving resource accumulation. Baseline corticosterone (CORT, the primary avian glucocorticoid) mediates daily and seasonal energetics, responds to changes in food availability, and has been linked to foraging behavior, making it a strong potential driver of individual variation in resource accrual and deposition. Working with a captive colony of white-winged scoters (Melanitta fusca deglandi), we aimed to causally determine whether variation in baseline CORT drives individual body mass gains mediated through fattening rate (plasma triglycerides corrected for body mass). We implanted individuals with each of three treatment pellets to elevate CORT within a baseline range in a randomized order: control, low dose of CORT, high dose of CORT, then blood sampled and recorded body mass over a two-week period to track changes in baseline CORT, body mass, and fattening rates. The high CORT treatment significantly elevated levels of plasma hormone for a short period of time within the biologically relevant, baseline range for this species, but importantly did not inhibit the function of the HPA (hypothalamic-pituitary-adrenal) axis. Furthermore, an elevation in baseline CORT resulted in a consistent increase in body mass throughout the trial period compared to controls. This is some of the first empirical evidence demonstrating that elevations of baseline CORT within a biologically relevant range have a causal, direct, and positive influence on changes in body mass.

  7. Comparison of CFD Predictions of the TCA Baseline

    Science.gov (United States)

    Cappuccio, Gelsomina

    1999-01-01

    The computational fluid dynamics (CFD) comparisons being presented are compared to each other and to wind tunnel (WT) data on the baseline TCA. Some of the CFD computations were done prior to the tests and others later. Only force data (CL vs CD) from CFD will be presented as part of this report. The WT data presented comes from the testing of the baseline TCA in the Langley Unitary Plan Wind Tunnel (UPWT), Test Section #2. There are 2 sets of wind tunnel data being presented: one from test 1671 of model 2a (flapped wing) and the other from test 1679 of model 2b (solid wing). Most of the plots show only one run from each of the WT tests per configuration. But many repeat runs were taken during the tests. The WT repeat runs showed an uncertainty in the drag of +/- 0.5 count. There were times when the uncertainty in drag was better, +/- 0.25 count. Test 1671 data was of forces and pressures measured from model 2a. The wing had cutouts for installing various leading and trailing edge flaps at lower Mach numbers. The internal duct of the nacelles are not designed and fabricated as defined in the outer mold lines (OML) iges file. The internal duct was fabricated such that a linear transition occurs from the inlet to exhaust. Whereas, the iges definition has a constant area internal duct that quickly transitions from the inlet to exhaust cross sectional shape. The nacelle internal duct was fabricated, the way described, to save time and money. The variation in the cross sectional area is less than 1% from the iges definition. The nacelles were also installed with and without fairings. Fairings are defined as the build up of the nacelles on the upper wing surface so that the nacelles poke through the upper surface as defined in the OML iges file. Test 1679 data was of forces measured from model 2a and 2b. The wing for model 2b was a solid wing. The nacelles were built the same way as for model 2a, except for the nacelle base pressure installation. The nacelles were only

  8. Establishing a store baseline during interim storage of waste packages and a review of potential technologies for base-lining

    Energy Technology Data Exchange (ETDEWEB)

    McTeer, Jennifer; Morris, Jenny; Wickham, Stephen [Galson Sciences Ltd. Oakham, Rutland (United Kingdom); Bolton, Gary [National Nuclear Laboratory Risley, Warrington (United Kingdom); McKinney, James; Morris, Darrell [Nuclear Decommissioning Authority Moor Row, Cumbria (United Kingdom); Angus, Mike [National Nuclear Laboratory Risley, Warrington (United Kingdom); Cann, Gavin; Binks, Tracey [National Nuclear Laboratory Sellafield (United Kingdom)

    2013-07-01

    Interim storage is an essential component of the waste management lifecycle, providing a safe, secure environment for waste packages awaiting final disposal. In order to be able to monitor and detect change or degradation of the waste packages, storage building or equipment, it is necessary to know the original condition of these components (the 'waste storage system'). This paper presents an approach to establishing the baseline for a waste-storage system, and provides guidance on the selection and implementation of potential base-lining technologies. The approach is made up of two sections; assessment of base-lining needs and definition of base-lining approach. During the assessment of base-lining needs a review of available monitoring data and store/package records should be undertaken (if the store is operational). Evolutionary processes (affecting safety functions), and their corresponding indicators, that can be measured to provide a baseline for the waste-storage system should then be identified in order for the most suitable indicators to be selected for base-lining. In defining the approach, identification of opportunities to collect data and constraints is undertaken before selecting the techniques for base-lining and developing a base-lining plan. Base-lining data may be used to establish that the state of the packages is consistent with the waste acceptance criteria for the storage facility and to support the interpretation of monitoring and inspection data collected during store operations. Opportunities and constraints are identified for different store and package types. Technologies that could potentially be used to measure baseline indicators are also reviewed. (authors)

  9. The deterioration of signal to noise ratio due to baseline restoration

    International Nuclear Information System (INIS)

    Henein, K.L.

    1976-02-01

    The deterioration of signal to noise ratio due to baseline restoration is theoretically studied. This study brings to the conclusion that a restorer has negligible influence on the signal to noise ratio when its time constant is ten times greater than that of the main amplifier filter, and that the rapid restorers prevail over the slow ones when the time constant of the filter is increased by at least 50% of its optimal value [fr

  10. Effects of baseline conditions on the simulated hydrologic response to projected climate change

    Science.gov (United States)

    Koczot, Kathryn M.; Markstrom, Steven L.; Hay, Lauren E.

    2011-01-01

    Changes in temperature and precipitation projected from five general circulation models, using one late-twentieth-century and three twenty-first-century emission scenarios, were downscaled to three different baseline conditions. Baseline conditions are periods of measured temperature and precipitation data selected to represent twentieth-century climate. The hydrologic effects of the climate projections are evaluated using the Precipitation-Runoff Modeling System (PRMS), which is a watershed hydrology simulation model. The Almanor Catchment in the North Fork of the Feather River basin, California, is used as a case study. Differences and similarities between PRMS simulations of hydrologic components (i.e., snowpack formation and melt, evapotranspiration, and streamflow) are examined, and results indicate that the selection of a specific time period used for baseline conditions has a substantial effect on some, but not all, hydrologic variables. This effect seems to be amplified in hydrologic variables, which accumulate over time, such as soil-moisture content. Results also indicate that uncertainty related to the selection of baseline conditions should be evaluated using a range of different baseline conditions. This is particularly important for studies in basins with highly variable climate, such as the Almanor Catchment.

  11. Baseline and annual repeat rounds of screening. Implications for optimal regimens of screening

    Energy Technology Data Exchange (ETDEWEB)

    Henschke, Claudia I.; Salvatore, Mary; Cham, Matthew; Eber, Corey; Yip, Rowena; Yankelevitz, David F. [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Powell, Charles A.; DiFabrizio, Larry [Icahn School of Medicine at Mount Sinai, Department of Medicine, New York, NY (United States); Flores, Raja; Kaufman, Andrew [Icahn School of Medicine at Mount Sinai, Department of Thoracic Surgery, New York, NY (United States); Collaboration: International Early Lung Cancer Action Program Investigators

    2018-03-15

    Differences in results of baseline and subsequent annual repeat rounds provide important information for optimising the regimen of screening. A prospective cohort study of 65,374 was reviewed to examine the frequency/percentages of the largest noncalcified nodule (NCN), lung cancer cell types and Kaplan-Meier (K-M) survival rates, separately for baseline and annual rounds. Of 65,374 baseline screenings, NCNs were identified in 28,279 (43.3%); lung cancer in 737 (1.1%). Of 74,482 annual repeat screenings, new NCNs were identified in 4959 (7%); lung cancer in 179 (0.24%). Only adenocarcinoma was diagnosed in subsolid NCNs. Percentages of lung cancers by cell type were significantly different (p < 0.0001) in the baseline round compared with annual rounds, reflecting length bias, as were the ratios, reflecting lead times. Long-term K-M survival rate was 100% for typical carcinoids and for adenocarcinomas manifesting as subsolid NCNs; 85% (95% CI 81-89%) for adenocarcinoma, 74% (95% CI 63-85%) for squamous cell, 48% (95% CI 34-62%) for small cell. The rank ordering by lead time was the same as the rank ordering by survival rates. The significant differences in the frequency of NCNs and frequency and aggressiveness of diagnosed cancers in baseline and annual repeat need to be recognised for an optimal regimen of screening. (orig.)

  12. An Automated Baseline Correction Method Based on Iterative Morphological Operations.

    Science.gov (United States)

    Chen, Yunliang; Dai, Liankui

    2018-05-01

    Raman spectra usually suffer from baseline drift caused by fluorescence or other reasons. Therefore, baseline correction is a necessary and crucial step that must be performed before subsequent processing and analysis of Raman spectra. An automated baseline correction method based on iterative morphological operations is proposed in this work. The method can adaptively determine the structuring element first and then gradually remove the spectral peaks during iteration to get an estimated baseline. Experiments on simulated data and real-world Raman data show that the proposed method is accurate, fast, and flexible for handling different kinds of baselines in various practical situations. The comparison of the proposed method with some state-of-the-art baseline correction methods demonstrates its advantages over the existing methods in terms of accuracy, adaptability, and flexibility. Although only Raman spectra are investigated in this paper, the proposed method is hopefully to be used for the baseline correction of other analytical instrumental signals, such as IR spectra and chromatograms.

  13. A SURVEY OF ASTRONOMICAL RESEARCH: A BASELINE FOR ASTRONOMICAL DEVELOPMENT

    International Nuclear Information System (INIS)

    Ribeiro, V. A. R. M.; Russo, P.; Cárdenas-Avendaño, A.

    2013-01-01

    Measuring scientific development is a difficult task. Different metrics have been put forward to evaluate scientific development; in this paper we explore a metric that uses the number of peer-reviewed, and when available non-peer-reviewed, research articles as an indicator of development in the field of astronomy. We analyzed the available publication record, using the Smithsonian Astrophysical Observatory/NASA Astrophysics Database System, by country affiliation in the time span between 1950 and 2011 for countries with a gross national income of less than 14,365 USD in 2010. This represents 149 countries. We propose that this metric identifies countries in ''astronomical development'' with a culture of research publishing. We also propose that for a country to develop in astronomy, it should invest in outside expert visits, send its staff abroad to study, and establish a culture of scientific publishing. Furthermore, we propose that this paper may be used as a baseline to measure the success of major international projects, such as the International Year of Astronomy 2009

  14. Control advances for achieving the ITER baseline scenario on KSTAR

    Science.gov (United States)

    Eidietis, N. W.; Barr, J.; Hahn, S. H.; Humphreys, D. A.; in, Y. K.; Jeon, Y. M.; Lanctot, M. J.; Mueller, D.; Walker, M. L.

    2017-10-01

    Control methodologies developed to enable successful production of ITER baseline scenario (IBS) plasmas on the superconducting KSTAR tokamak are presented: decoupled vertical control (DVC), real-time feedforward (rtFF) calculation, and multi-input multi-output (MIMO) X-point control. DVC provides fast vertical control with the in-vessel control coils (IVCC) while sharing slow vertical control with the poloidal field (PF) coils to avoid IVCC saturation. rtFF compensates for inaccuracies in offline PF current feedforward programming, allowing reduction or removal of integral gain (and its detrimental phase lag) from the shape controller. Finally, MIMO X-point control provides accurate positioning of the X-point despite low controllability due to the large distance between coils and plasma. Combined, these techniques enabled achievement of IBS parameters (q95 = 3.2, βN = 2) with a scaled ITER shape on KSTAR. n =2 RMP response displays a strong dependence upon this shaping. Work supported by the US DOE under Award DE-SC0010685 and the KSTAR project.

  15. Trunk muscle activation during golf swing: Baseline and threshold.

    Science.gov (United States)

    Silva, Luís; Marta, Sérgio; Vaz, João; Fernandes, Orlando; Castro, Maria António; Pezarat-Correia, Pedro

    2013-10-01

    There is a lack of studies regarding EMG temporal analysis during dynamic and complex motor tasks, such as golf swing. The aim of this study is to analyze the EMG onset during the golf swing, by comparing two different threshold methods. Method A threshold was determined using the baseline activity recorded between two maximum voluntary contraction (MVC). Method B threshold was calculated using the mean EMG activity for 1000ms before the 500ms prior to the start of the Backswing. Two different clubs were also studied. Three-way repeated measures ANOVA was used to compare methods, muscles and clubs. Two-way mixed Intraclass Correlation Coefficient (ICC) with absolute agreement was used to determine the methods reliability. Club type usage showed no influence in onset detection. Rectus abdominis (RA) showed the higher agreement between methods. Erector spinae (ES), on the other hand, showed a very low agreement, that might be related to postural activity before the swing. External oblique (EO) is the first being activated, at 1295ms prior impact. There is a similar activation time between right and left muscles sides, although the right EO showed better agreement between methods than left side. Therefore, the algorithms usage is task- and muscle-dependent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Investigation of Baseline Antioxidant Enzyme Expression in Pocillopora damicornis

    Science.gov (United States)

    Murphy, J.; Richmond, R. H.

    2016-02-01

    Coral reefs are some of the most diverse and valuable ecosystems in the world. Vital for maintaining ecological balance in coastal tropical environments, they also stand as the foundation for enormous cultural and economic resources. However, the continued degradation of coral reefs around the world, particularly within NOAA's Hawaii Marine Sanctuary, is an alarming call for action towards the identification of stressors and subsequent rehabilitation of these national treasures. Aligned with the goals of NOAA's National Marine Sanctuary to protect areas of the marine environment that are of special national significance to cultural, scientific, educational, and ecological values, this research targets addressing and standardizing antioxidant enzyme stress levels in Hawaiian coral over reproductive cycles in order to increase management aptitude and efficiency. By developing a greater understanding for biochemical biomarkers of stress in corals, specifically through the study of superoxide dismutase, catalase, glutathione peroxidase, and glutathione reductase activity and expression, my research will aid in the adaptation and further development of biochemical tests to understand baseline thresholds of stress on coral reefs within Sanctuary waters. Slight, but significant variations in enzyme expression over reproductive time points alert us to modifications that must be made to consider fluctuating levels of coral susceptibility when sampling corals under stress. These findings will be applied to diagnostic tests describing the effect of different chemical pollutants on coral health in order to identify ecological issues and expand the knowledge of local communities and NOAA, so that steps can be taken to mitigate human Sanctuary impacts.

  17. Baseline Cerebral Small Vessel Disease Is Not Associated with Gait Decline After Five Years

    NARCIS (Netherlands)

    Van Der Holst, Helena M.; Van Uden, Ingeborg W.M.; de Laat, Karlijn F.; Van Leijsen, Esther M.C.; van Norden, Anouk G.W.; Norris, David G.; Van DIjk, Ewoud J.; Tuladhar, Anil M.; de Leeuw, Frank-Erik

    2017-01-01

    Background Cerebral small vessel disease (SVD) is cross-sectionally associated with gait disturbances, however, the relation between baseline SVD and gait decline over time is uncertain. Furthermore, diffusion tensor imaging (DTI) studies on gait decline are currently lacking. Objective To

  18. Wind power projects in the CDM: Methodologies and tools for baselines, carbon financing and sustainability analysis

    International Nuclear Information System (INIS)

    Ringius, L.; Grohnheit, P.E.; Nielsen, L.H.; Olivier, A.L.; Painuly, J.; Villavicencio, A.

    2002-12-01

    profile of Zafarana, the emission rates estimated by runs with 1 hour time-steps of the simulation tool ES3 range from 0.590 tCO 2 /MWh to 0.610 tCO 2 /MWh. These results come very close to estimates based on two different interpretations of standardized baseline options above. (au)

  19. Baseline factors that influence ASAS 20 response in patients with ankylosing spondylitis treated with etanercept.

    Science.gov (United States)

    Davis, John C; Van der Heijde, Désirée M F M; Dougados, Maxime; Braun, Jurgen; Cush, John J; Clegg, Daniel O; Inman, Robert D; de Vries, Todd; Tsuji, Wayne H

    2005-09-01

    To examine the baseline demographic and disease characteristics that might influence improvement as measured by the Assessment in Ankylosing Spondylitis Response Criteria (ASAS 20) in patients with ankylosing spondylitis (AS). A multicenter Phase 3 study was performed to compare the safety and efficacy of 24 weeks of etanercept 25 mg subcutaneous injection twice weekly (n = 138) and placebo (n = 139) in patients with AS. The ASAS 20 was measured at multiple time points. Using a significance level of 0.05, a repeated measures logistic regression model was used to determine which baseline factors influenced response in the etanercept-treated patients during the 24-week double blind portion of the trial. The following baseline factors were used in the model: demographic and disease severity variables, concomitant medications, extra-articular manifestations, and HLA-B27 status. The predictive capability of the model was then tested on the patients receiving placebo after they had received open-label etanercept treatment. Baseline factors that were significant predictors of an ASAS 20 response in etanercept-treated patients were C-reactive protein (CRP), back pain score, and Bath Ankylosing Spondylitis Functional Index (BASFI) score. Although clinical response to etanercept was seen at all levels of baseline disease activity, responses were consistently more likely with higher CRP levels or back pain scores and less likely with increased BASFI scores at baseline. Higher CRP values and back pain scores and lower BASFI scores at baseline were significant predictors of a higher ASAS 20 response in patients with AS receiving etanercept but predictive value was of insufficient magnitude to determine treatment in individual patients.

  20. CryoSat SAR/SARin Level1b products: assessment of BaselineC and improvements towards BaselineD

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Bouffard, Jerome; Parrinello, Tommaso

    2017-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. Cryosat carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach a significantly improved along track resolution with respect to traditional pulse-width limited altimeters. CryoSat is the first altimetry mission operating in SAR mode and continuous improvements in the Level1 Instrument Processing Facility (IPF1) are being identified, tested and validated in order to improve the quality of the Level1b products. The current IPF, Baseline C, was released in operation in April 2015 and the second CryoSat reprocessing campaign was jointly initiated, taking benefit of the upgrade implemented in the IPF1 processing chain but also of some specific configurations for the calibration corrections. In particular, the CryoSat Level1b BaselineC products generated in the framework of the second reprocessing campaign include refined information for what concerns the mispointing angles and the calibration corrections. This poster will thus detail thus the evolutions that are currently planned for the CryoSat BaselineD SAR/SARin Level1b products and the corresponding quality improvements that are expected.

  1. Strategies for baseline/environmental impact studies in Nigeria

    International Nuclear Information System (INIS)

    Odu, C.T.

    1991-01-01

    This paper reports that in order to assess the environmental impact of site activities and ecosystem change brought about by stress, basic baseline data are necessary to characterize the normal environment so that environmental quality control programs can be developed with a firm ecological base. The program and methodology adopted in our field surveys to assess the character, magnitude and extent of pollutant effects on soil, vegetation and water, as a basis for economic assessment of pollutant effects on agriculture, forestry and the aquatic system and for preparing environmental impact statements, are presented. These techniques were modified and adopted in the environmental impact study of the Isampou Manifold Oil Spill, a study which circumstances made necessary seven years after the oil spill. Reliance on the extent of pollution soon after the incidence was based on the determination of total hydrocarbons at creek bottoms as well as on the determinations of nickel/vanadium ratios. Hydrocarbon contents of creek banks and creek bottoms were within biogenic levels at the time of field sampling. Ni/V ratios were high in heavy impact areas and decreased in areas of medium and very light impact areas. Use of the Ni/V ratio as evidence of past oil pollution agreed closely with a sketch of the extent of crude oil pollution drawn by the Shell Petroleum Development Company seven years earlier. There were nor abnormal vegetation features. The presence of 10-15 years old Musanga cecropioides at the edge of the manifold slot and creeks indicated that vegetation above water level was not affected by the oil spillage. The physico-chemical properties of the waters, plankton composition and density of the species found, as well as the presence of endroproct bryozoan in the benthos showed that the aquatic system had by the time of sample collection, completely recovered from the oil spillage

  2. Shifting baselines and the extinction of the Caribbean monk seal.

    Science.gov (United States)

    Baisre, Julio A

    2013-10-01

    The recent extinction of the Caribbean monk seal Monachus tropicalis has been considered an example of a human-caused extinction in the marine environment, and this species was considered a driver of the changes that have occurred in the structure of Caribbean coral reef ecosystems since colonial times. I searched archaeological records, historical data, and geographic names (used as a proxy of the presence of seals) and evaluated the use and quality of these data to conclude that since prehistoric times the Caribbean monk seal was always rare and vulnerable to human predation. This finding supports the hypothesis that in AD 1500, the Caribbean monk seal persisted as a small fragmented population in which individuals were confined to small keys, banks, or isolated islands in the Gulf of Mexico and the Caribbean Sea. This hypothesis is contrary to the assumption that the species was widespread and abundant historically. The theory that the main driver of monk seal extinction was harvesting for its oil for use in the sugar cane industry of Jamaica during the 18th century is based primarily on anecdotal information and is overemphasized in the literature. An analysis of reported human encounters with this species indicates monk seal harvest was an occasional activity, rather than an ongoing enterprise. Nevertheless, given the rarity of this species and its restricted distribution, even small levels of hunting or specimen collecting must have contributed to its extinction, which was confirmed in the mid-20th century. Some sources had been overlooked or only partially reviewed, others misinterpreted, and a considerable amount of anecdotal information had been uncritically used. Critical examination of archaeological and historical records is required to infer accurate estimations of the historical abundance of a species. In reconstructing the past to address the shifting baseline syndrome, it is important to avoid selecting evidence to confirm modern prejudices. © 2013

  3. Baseline Biomarkers for Outcome of Melanoma Patients Treated with Pembrolizumab

    NARCIS (Netherlands)

    Weide, Benjamin; Martens, Alexander; Hassel, Jessica C.; Berking, Carola; Postow, Michael A.; Bisschop, Kees; Simeone, Ester; Mangana, Johanna; Schilling, Bastian; Di Giacomo, Anna Maria; Brenner, Nicole; Kaehler, Katharina; Heinzerling, Lucie; Gutzmer, Ralf; Bender, Armin; Gebhardt, Christoffer; Romano, Emanuela; Meier, Friedegund; Martus, Peter; Maio, Michele; Blank, Christian; Schadendorf, Dirk; Dummer, Reinhard; Ascierto, Paolo A.; Hospers, Geke; Garbe, Claus; Wolchok, Jedd D.

    2016-01-01

    Purpose: Biomarkers for outcome after immune-checkpoint blockade are strongly needed as these may influence individual treatment selection or sequence. We aimed to identify baseline factors associated with overall survival (OS) after pembrolizumab treatment in melanoma patients. Experimental Design:

  4. Baseline assessment of fish communities of the Flower Garden Banks

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The work developed baseline information on fish and benthic communities within the Flower Garden Banks National Marine Sanctuary (FGBNMS). Surveys employed diving,...

  5. Information architecture. Volume 2, Part 1: Baseline analysis summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The Department of Energy (DOE) Information Architecture, Volume 2, Baseline Analysis, is a collaborative and logical next-step effort in the processes required to produce a Departmentwide information architecture. The baseline analysis serves a diverse audience of program management and technical personnel and provides an organized way to examine the Department`s existing or de facto information architecture. A companion document to Volume 1, The Foundations, it furnishes the rationale for establishing a Departmentwide information architecture. This volume, consisting of the Baseline Analysis Summary (part 1), Baseline Analysis (part 2), and Reference Data (part 3), is of interest to readers who wish to understand how the Department`s current information architecture technologies are employed. The analysis identifies how and where current technologies support business areas, programs, sites, and corporate systems.

  6. Magical properties of a 2540 km baseline superbeam experiment

    International Nuclear Information System (INIS)

    Raut, Sushant K.; Singh, Ravi Shanker; Uma Sankar, S.

    2011-01-01

    Lack of any information on the CP violating phase δ CP weakens our ability to determine neutrino mass hierarchy. Magic baseline of 7500 km was proposed to overcome this problem. However, to obtain large enough fluxes, at this very long baseline, one needs new techniques of generating high intensity neutrino beams. In this Letter, we highlight the magical properties of a 2540 km baseline. At such a baseline, using a narrow band neutrino superbeam whose no oscillation event rate peaks around the energy 3.5 GeV, we can determine neutrino mass hierarchy independently of the CP phase. For sin 2 2θ 13 ≥0.05, a very modest exposure of 10 Kiloton-years is sufficient to determine the hierarchy. For 0.02≤sin 2 2θ 13 ≤0.05, an exposure of about 100 Kiloton-years is needed.

  7. Effect of education and language on baseline concussion screening tests in professional baseball players.

    Science.gov (United States)

    Jones, Nathaniel S; Walter, Kevin D; Caplinger, Roger; Wright, Daniel; Raasch, William G; Young, Craig

    2014-07-01

    The purpose of the present study was to investigate the possible effects of sociocultural influences, specifically pertaining to language and education, on baseline neuropsychological concussion testing as obtained via immediate postconcussion assessment and cognitive testing (ImPACT) of players from a professional baseball team. A retrospective chart review. Baseline testing of a professional baseball organization. Four hundred five professional baseball players. Age, languages spoken, hometown country location (United States/Canada vs overseas), and years of education. The 5 ImPACT composite scores (verbal memory, visual memory, visual motor speed, reaction time, impulse control) and ImPACT total symptom score from the initial baseline testing. The result of t tests revealed significant differences (P education, the significant differences (P < 0.05) remained in some scores. Sociocultural differences may result in differences in computer-based neuropsychological testing scores.

  8. Validity and Reliability of Baseline Testing in a Standardized Environment.

    Science.gov (United States)

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method.

    Science.gov (United States)

    Shen, Yueqian; Lindenbergh, Roderik; Wang, Jinhu

    2016-12-24

    A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.

  10. Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method

    Directory of Open Access Journals (Sweden)

    Yueqian Shen

    2016-12-01

    Full Text Available A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.

  11. Baseliner: An open-source, interactive tool for processing sap flux data from thermal dissipation probes

    Directory of Open Access Journals (Sweden)

    A. Christopher Oishi

    2016-01-01

    Full Text Available Estimating transpiration from woody plants using thermal dissipation sap flux sensors requires careful data processing. Currently, researchers accomplish this using spreadsheets, or by personally writing scripts for statistical software programs (e.g., R, SAS. We developed the Baseliner software to help establish a standardized protocol for processing sap flux data. Baseliner enables users to QA/QC data and process data using a combination of automated steps, visualization, and manual editing. Data processing requires establishing a zero-flow reference value, or “baseline”, which varies among sensors and with time. Since no set of algorithms currently exists to reliably QA/QC and estimate the zero-flow baseline, Baseliner provides a graphical user interface to allow visual inspection and manipulation of data. Data are first automatically processed using a set of user defined parameters. The user can then view the data for additional, manual QA/QC and baseline identification using mouse and keyboard commands. The open-source software allows for user customization of data processing algorithms as improved methods are developed.

  12. Infrared thermometry and the crop water stress index. I. History, theory, and baselines

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Development of portable infrared thermometers and the definition of the Crop Water Stress Index (CWSI) have led to widespread interest in infrared thermometry to monitor water stress and schedule irrigations. But the CWSI concept is still new and poorly understood by many. The purpose of this paper is to review the definition of CWSI, and the determination and interpretation of the non-water-stressed baselines used to compute CWSI. The non-water-stressed baseline equation normalizes the canopy minus air temperature differential for variations in vapor pressure deficit. Non-water-stressed baselines can be determined empirically from measurements of canopy and air temperatures and vapor pressure deficit, made diurnally on a single day, or at a single time of day over many days, on well-watered plants. The value of the maximum canopy minus air temperature differential under maximum water stress should also be determined empirically. Causes for CWSI values falling outside of the defined 0 to 10 unit range are reviewed. Non-water-stressed baselines may shift with plant growth stage. Effective use of CWSI is dependent on understanding the definition of CWSI, and the proper determination and use of non-water-stressed baselines. (author)

  13. THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

    Energy Technology Data Exchange (ETDEWEB)

    Partnership, ALMA [Astrophysics Research Institute, Liverpool John Moores University, IC2, Liverpool Science Park, 146 Brownlow Hill, Liverpool L3 5RF (United Kingdom); Fomalont, E. B.; Vlahakis, C.; Corder, S.; Remijan, A.; Barkats, D.; Dent, W. R. F.; Phillips, N.; Cox, P.; Hales, A. S. [Joint ALMA Observatory, Alonso de Córdova 3107, Vitacura, Santiago (Chile); Lucas, R. [Institut de Planétologie et d’Astrophysique de Grenoble (UMR 5274), BP 53, F-38041 Grenoble Cedex 9 (France); Hunter, T. R.; Brogan, C. L.; Amestica, R.; Cotton, W. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Asaki, Y. [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Matsushita, S. [Institute of Astronomy and Astrophysics, Academia Sinica, P.O. Box 23-141, Taipei 106, Taiwan (China); Hills, R. E. [Astrophysics Group, Cavendish Laboratory, JJ Thomson Avenue, Cambridge CB3 0HE (United Kingdom); Richards, A. M. S. [Jodrell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Broguiere, D., E-mail: efomalon@nrao.edu [Institut de Radioastronomie Millime´trique (IRAM), 300 rue de la Piscine, Domaine Universitaire, F-38406 Saint Martin d’Hères (France); and others

    2015-07-20

    A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy.

  14. A Fully Customized Baseline Removal Framework for Spectroscopic Applications.

    Science.gov (United States)

    Giguere, Stephen; Boucher, Thomas; Carey, C J; Mahadevan, Sridhar; Dyar, M Darby

    2017-07-01

    The task of proper baseline or continuum removal is common to nearly all types of spectroscopy. Its goal is to remove any portion of a signal that is irrelevant to features of interest while preserving any predictive information. Despite the importance of baseline removal, median or guessed default parameters are commonly employed, often using commercially available software supplied with instruments. Several published baseline removal algorithms have been shown to be useful for particular spectroscopic applications but their generalizability is ambiguous. The new Custom Baseline Removal (Custom BLR) method presented here generalizes the problem of baseline removal by combining operations from previously proposed methods to synthesize new correction algorithms. It creates novel methods for each technique, application, and training set, discovering new algorithms that maximize the predictive accuracy of the resulting spectroscopic models. In most cases, these learned methods either match or improve on the performance of the best alternative. Examples of these advantages are shown for three different scenarios: quantification of components in near-infrared spectra of corn and laser-induced breakdown spectroscopy data of rocks, and classification/matching of minerals using Raman spectroscopy. Software to implement this optimization is available from the authors. By removing subjectivity from this commonly encountered task, Custom BLR is a significant step toward completely automatic and general baseline removal in spectroscopic and other applications.

  15. THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW

    International Nuclear Information System (INIS)

    Partnership, ALMA; Fomalont, E. B.; Vlahakis, C.; Corder, S.; Remijan, A.; Barkats, D.; Dent, W. R. F.; Phillips, N.; Cox, P.; Hales, A. S.; Lucas, R.; Hunter, T. R.; Brogan, C. L.; Amestica, R.; Cotton, W.; Asaki, Y.; Matsushita, S.; Hills, R. E.; Richards, A. M. S.; Broguiere, D.

    2015-01-01

    A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to ∼15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at ∼350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy

  16. Precise baseline determination for the TanDEM-X mission

    Science.gov (United States)

    Koenig, Rolf; Moon, Yongjin; Neumayer, Hans; Wermuth, Martin; Montenbruck, Oliver; Jäggi, Adrian

    The TanDEM-X mission will strive for generating a global precise Digital Elevation Model (DEM) by way of bi-static SAR in a close formation of the TerraSAR-X satellite, already launched on June 15, 2007, and the TanDEM-X satellite to be launched in May 2010. Both satellites carry the Tracking, Occultation and Ranging (TOR) payload supplied by the GFZ German Research Centre for Geosciences. The TOR consists of a high-precision dual-frequency GPS receiver, called Integrated GPS Occultation Receiver (IGOR), and a Laser retro-reflector (LRR) for precise orbit determination (POD) and atmospheric sounding. The IGOR is of vital importance for the TanDEM-X mission objectives as the millimeter level determination of the baseline or distance between the two spacecrafts is needed to derive meter level accurate DEMs. Within the TanDEM-X ground segment GFZ is responsible for the operational provision of precise baselines. For this GFZ uses two software chains, first its Earth Parameter and Orbit System (EPOS) software and second the BERNESE software, for backup purposes and quality control. In a concerted effort also the German Aerospace Center (DLR) generates precise baselines independently with a dedicated Kalman filter approach realized in its FRNS software. By the example of GRACE the generation of baselines with millimeter accuracy from on-board GPS data can be validated directly by way of comparing them to the intersatellite K-band range measurements. The K-band ranges are accurate down to the micrometer-level and therefore may be considered as truth. Both TanDEM-X baseline providers are able to generate GRACE baselines with sub-millimeter accuracy. By merging the independent baselines by GFZ and DLR, the accuracy can even be increased. The K-band validation however covers solely the along-track component as the K-band data measure just the distance between the two GRACE satellites. In addition they inhibit an un-known bias which must be modelled in the comparison, so the

  17. Baseline Assessment of Petroleum Contamination and Soil Properties at Contaminated Sites in Utqiagvik, Alaska

    Science.gov (United States)

    2017-08-01

    microbial community, including high bacterial numbers in these soils. The results from this baseline study indicate that stimulating biodegradation...CEERD-RR), ERDC- CRREL. At the time of publication, Dr. Justin Berman was Chief, CEERD- RRN; CDR J. D. Horne, USN (Ret), was Chief, CEERD-RR; and Dr...of the fractions of petroleum hydrocarbons and microbial activity in ERDC/CRREL TR-17-13 3 situ to reveal the status of each site at the time of

  18. The relationship between psychological distress and baseline sports-related concussion testing.

    Science.gov (United States)

    Bailey, Christopher M; Samples, Hillary L; Broshek, Donna K; Freeman, Jason R; Barth, Jeffrey T

    2010-07-01

    This study examined the effect of psychological distress on neurocognitive performance measured during baseline concussion testing. Archival data were utilized to examine correlations between personality testing and computerized baseline concussion testing. Significantly correlated personality measures were entered into linear regression analyses, predicting baseline concussion testing performance. Suicidal ideation was examined categorically. Athletes underwent testing and screening at a university athletic training facility. Participants included 47 collegiate football players 17 to 19 years old, the majority of whom were in their first year of college. Participants were administered the Concussion Resolution Index (CRI), an internet-based neurocognitive test designed to monitor and manage both at-risk and concussed athletes. Participants took the Personality Assessment Inventory (PAI), a self-administered inventory designed to measure clinical syndromes, treatment considerations, and interpersonal style. Scales and subscales from the PAI were utilized to determine the influence psychological distress had on the CRI indices: simple reaction time, complex reaction time, and processing speed. Analyses revealed several significant correlations among aspects of somatic concern, depression, anxiety, substance abuse, and suicidal ideation and CRI performance, each with at least a moderate effect. When entered into a linear regression, the block of combined psychological symptoms accounted for a significant amount of baseline CRI performance, with moderate to large effects (r = 0.23-0.30). When examined categorically, participants with suicidal ideation showed significantly slower simple reaction time and complex reaction time, with a similar trend on processing speed. Given the possibility of obscured concussion deficits after injury, implications for premature return to play, and the need to target psychological distress outright, these findings heighten the clinical

  19. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation.

    Science.gov (United States)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A; Thieden, Elisabeth; Wulf, Hans C

    2010-02-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol was measured at baseline. The increase in 25(OH)D level after UVB exposure was negatively correlated with baseline 25(OH)D level (Ppigmentation. In addition, we paired a dark-skinned group with a fair-skinned group according to baseline 25(OH)D levels and found no differences in 25(OH)D increase after identical UVB exposure.

  20. Baseline and premining geochemical characterization of mined sites

    Science.gov (United States)

    Nordstrom, D. Kirk

    2015-01-01

    A rational goal for environmental restoration of new, active, or inactive mine sites would be ‘natural background’ or the environmental conditions that existed before any mining activities or other related anthropogenic activities. In a strictly technical sense, there is no such thing as natural background (or entirely non-anthropogenic) existing today because there is no part of the planet earth that has not had at least some chemical disturbance from anthropogenic activities. Hence, the terms ‘baseline’ and ‘pre-mining’ are preferred to describe these conditions. Baseline conditions are those that existed at the time of the characterization which could be pre-mining, during mining, or post-mining. Protocols for geochemically characterizing pre-mining conditions are not well-documented for sites already mined but there are two approaches that seem most direct and least ambiguous. One is characterization of analog sites along with judicious application of geochemical modeling. The other is reactive-transport modeling (based on careful synoptic sampling with tracer-injection) and subtracting inputs from known mining and mineral processing. Several examples of acidic drainage are described from around the world documenting the range of water compositions produced from pyrite oxidation in the absence of mining. These analog sites provide insight to the processes forming mineralized waters in areas untouched by mining. Natural analog water-chemistry data is compared with the higher metal concentrations, metal fluxes, and weathering rates found in mined areas in the few places where comparisons are possible. The differences are generally 1–3 orders of magnitude higher for acid mine drainage.

  1. Carbon emission coefficient of power consumption in India: baseline determination from the demand side

    International Nuclear Information System (INIS)

    Nag, Barnali; Parikh, J.K.

    2005-01-01

    Substantial investments are expected in the Indian power sector under the flexibility mechanisms (CDM/JI) laid down in Article 12 of the Kyoto Protocol. In this context it is important to evolve a detailed framework for baseline construction in the power sector so as to incorporate the major factors that would affect the baseline values directly or indirectly. It is also important to establish carbon coefficients from electricity generation to help consider accurate project boundaries for numerous electricity conservation and DSM schemes. The objective of this paper is to provide (i) time series estimates of indirect carbon emissions per unit of power consumption (which can also be thought of as emission coefficient of power consumption) and (ii) baseline emissions for the power sector till 2015. Annual time series data on Indian electricity generating industry, for 1974-1998, has been used to develop emission projections till 2015. The impacts of generation mix, fuel efficiency, transmission and distribution losses and auxiliary consumption are studied in a Divisia decomposition framework and their possible future impacts on baseline emissions are studied through three scenarios of growth in power consumption. The study also estimates and projects the carbon emission coefficient per unit of final consumption of electricity that can be used for conducting cost benefit of emission reduction potential for several electricity conserving technologies and benchmarking policy models

  2. Sustained attention performance during sleep deprivation associates with instability in behavior and physiologic measures at baseline.

    Science.gov (United States)

    Chua, Eric Chern-Pin; Yeo, Sing-Chen; Lee, Ivan Tian-Guang; Tan, Luuan-Chin; Lau, Pauline; Cai, Shiwei; Zhang, Xiaodong; Puvanendran, Kathiravelu; Gooley, Joshua J

    2014-01-01

    To identify baseline behavioral and physiologic markers that associate with individual differences in sustained attention during sleep deprivation. In a retrospective study, ocular, electrocardiogram, and electroencephalogram (EEG) measures were compared in subjects who were characterized as resilient (n = 15) or vulnerable (n = 15) to the effects of total sleep deprivation on sustained attention. Chronobiology and Sleep Laboratory, Duke-NUS Graduate Medical School Singapore. Healthy volunteers aged 22-32 years from the general population. Subjects were kept awake for at least 26 hours under constant environmental conditions. Every 2 hours, sustained attention was assessed using a 10-minute psychomotor vigilance task (PVT). During baseline sleep and recovery sleep, EEG slow wave activity was similar in resilient versus vulnerable subjects, suggesting that individual differences in vulnerability to sleep loss were not related to differences in homeostatic sleep regulation. Rather, irrespective of time elapsed since wake, subjects who were vulnerable to sleep deprivation exhibited slower and more variable PVT response times, lower and more variable heart rate, and higher and more variable EEG spectral power in the theta frequency band (6.0-7.5 Hz). Performance decrements in sustained attention during sleep deprivation associate with instability in behavioral and physiologic measures at baseline. Small individual differences in sustained attention that are present at baseline are amplified during prolonged wakefulness, thus contributing to large between-subjects differences in performance and sleepiness.

  3. Effect of tidal cycle and food intake on the baseline plasma corticosterone rhythm in intertidally foraging marine iguanas.

    Science.gov (United States)

    Woodley, Sarah K; Painter, Danika L; Moore, Michael C; Wikelski, Martin; Romero, L Michael

    2003-06-15

    In most species, plasma levels of baseline glucocorticoids such as corticosterone (B) have a circadian rhythm. This rhythm can be entrained by both photoperiod and food intake and is related to aspects of energy intake and metabolism. Marine iguanas (Amblyrhynchus cristatus) offer a unique opportunity to better understand the relative importance of the light:dark cycle versus food intake in influencing the rhythm in baseline B in a natural system. Compared to other species, food intake is not as strictly determined by the phase of the light:dark cycle. Animals feed in the intertidal zone so feeding activity is heavily influenced by the tidal cycle. We measured baseline plasma B levels in free-living iguanas over several 24-h periods that varied in the timing of low tide/foraging activity. We found that baseline B levels were higher during the day relative to night. However, when low tide occurred during the day, baseline B levels dropped coincident with the timing of low tide. Whether the baseline B rhythm (including the drop during foraging) is an endogenous rhythm with a circatidal component, or is simply a result of feeding and associated physiological changes needs to be tested. Together, these data suggest that the baseline B rhythm in marine iguanas is influenced by the tidal cycle/food intake as well as the light:dark cycle.

  4. Baseline development, economic risk, and schedule risk: An integrated approach

    International Nuclear Information System (INIS)

    Tonkinson, J.A.

    1994-01-01

    The economic and schedule risks of Environmental Restoration (ER) projects are commonly analyzed toward the end of the baseline development process. Risk analysis is usually performed as the final element of the scheduling or estimating processes for the purpose of establishing cost and schedule contingency. However, there is an opportunity for earlier assessment of risks, during development of the technical scope and Work Breakdown Structure (WBS). Integrating the processes of risk management and baselining provides for early incorporation of feedback regarding schedule and cost risk into the proposed scope of work. Much of the information necessary to perform risk analysis becomes available during development of the technical baseline, as the scope of work and WBS are being defined. The analysis of risk can actually be initiated early on during development of the technical baseline and continue throughout development of the complete project baseline. Indeed, best business practices suggest that information crucial to the success of a project be analyzed and incorporated into project planning as soon as it is available and usable

  5. Earth matter effects at very long baselines and the neutrino mass hierarchy

    International Nuclear Information System (INIS)

    Gandhi, Raj; Ghoshal, Pomita; Goswami, Srubabati; Mehta, Poonam; Sankar, S. Uma

    2006-01-01

    We study matter effects which arise in the muon neutrino oscillation and survival probabilities relevant to atmospheric neutrino and very long baseline (>4000 Km) beam experiments. The interrelations between the three probabilities P μe , P μτ , and P μμ are examined. It is shown that large and observable sensitivity to the neutrino mass hierarchy can be present in P μμ and P μτ . We emphasize that at baselines >7000 Km, matter effects in P μτ are important under certain conditions and can be large. The muon survival rates in experiments with very long baselines thus depend on matter effects in both P μτ and P μe . We also indicate where these effects provide sensitivity to θ 13 and identify ranges of energies and baselines where this sensitivity is maximum. The effect of parameter degeneracies in the three probabilities at these baselines and energies is studied in detail and large parts of the parameter space are identified which are free from these degeneracies. In the second part of the paper, we focus on using the matter effects studied in the first part as a means of determining the mass hierarchy via atmospheric neutrinos. Realistic event rate calculations are performed for a charge discriminating 100 kT iron calorimeter which demonstrate the possibility of realizing this very important goal in neutrino physics. It is shown that for atmospheric neutrinos, a careful selection of energy and baseline ranges is necessary in order to obtain a statistically significant signal, and that the effects are largest in bins where matter effects in both P μe and P μτ combine constructively. Under these conditions, up to a 4σ signal for matter effects is possible (for Δ 31 >0) within a time scale appreciably shorter than the one anticipated for neutrino factories

  6. Is CP violation observable in long baseline neutrino oscillation experiments?

    International Nuclear Information System (INIS)

    Tanimoto, M.

    1997-01-01

    We have studied CP violation originating from the phase of the neutrino-mixing matrix in the long baseline neutrino oscillation experiments. The direct measurement of CP violation is the difference of the transition probabilities between CP-conjugate channels. In those experiments, the CP-violating effect is not suppressed if the highest neutrino mass scale is taken to be 1 endash 5 eV, which is appropriate for the cosmological hot dark matter. Assuming the hierarchy for the neutrino masses, the upper bounds of CP violation have been calculated for three cases, in which mixings are constrained by the recent short baseline ones. The calculated upper bounds are larger than 10 -2 , which will be observable in the long baseline accelerator experiments. The matter effect, which is not CP invariant, has been also estimated in those experiments. copyright 1997 The American Physical Society

  7. A publication database for optical long baseline interferometry

    Science.gov (United States)

    Malbet, Fabien; Mella, Guillaume; Lawson, Peter; Taillifet, Esther; Lafrasse, Sylvain

    2010-07-01

    Optical long baseline interferometry is a technique that has generated almost 850 refereed papers to date. The targets span a large variety of objects from planetary systems to extragalactic studies and all branches of stellar physics. We have created a database hosted by the JMMC and connected to the Optical Long Baseline Interferometry Newsletter (OLBIN) web site using MySQL and a collection of XML or PHP scripts in order to store and classify these publications. Each entry is defined by its ADS bibcode, includes basic ADS informations and metadata. The metadata are specified by tags sorted in categories: interferometric facilities, instrumentation, wavelength of operation, spectral resolution, type of measurement, target type, and paper category, for example. The whole OLBIN publication list has been processed and we present how the database is organized and can be accessed. We use this tool to generate statistical plots of interest for the community in optical long baseline interferometry.

  8. Functional Testing Protocols for Commercial Building Efficiency Baseline Modeling Software

    Energy Technology Data Exchange (ETDEWEB)

    Jump, David; Price, Phillip N.; Granderson, Jessica; Sohn, Michael

    2013-09-06

    This document describes procedures for testing and validating proprietary baseline energy modeling software accuracy in predicting energy use over the period of interest, such as a month or a year. The procedures are designed according to the methodology used for public domain baselining software in another LBNL report that was (like the present report) prepared for Pacific Gas and Electric Company: ?Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing Protocols? (referred to here as the ?Model Analysis Report?). The test procedure focuses on the quality of the software?s predictions rather than on the specific algorithms used to predict energy use. In this way the software vendor is not required to divulge or share proprietary information about how their software works, while enabling stakeholders to assess its performance.

  9. Carbon tetrachloride ERA soil-gas baseline monitoring

    International Nuclear Information System (INIS)

    Fancher, J.D.

    1994-01-01

    From December 1991 through December 1993, Westinghouse Hanford Company performed routine baseline monitoring of selected wells ad soil-gas points twice weekly in the 200 West Area of the Hanford Site. This work supported the carbon Tetrachloride Expedited Response Action (ERA) and provided a solid baseline of volatile organic compound (VOC) concentrations in wells and in the subsurface at the ERA site. As site remediation continues, comparisons to this baseline can be one means of measuring the success of carbon tetrachloride vapor extraction. This report contains observations of the patterns and trends associated with data obtained during soil-gas monitoring at the 200 West Area: Monitoring performed since late 1991 includes monitoring soil-gas probes ad wellheads for volatile organic compounds (VOCs). This report reflects monitoring data collected from December 1991 through December 1993

  10. Environmental baselines: preparing for shale gas in the UK

    Science.gov (United States)

    Bloomfield, John; Manamsa, Katya; Bell, Rachel; Darling, George; Dochartaigh, Brighid O.; Stuart, Marianne; Ward, Rob

    2014-05-01

    Groundwater is a vital source of freshwater in the UK. It provides almost 30% of public water supply on average, but locally, for example in south-east England, it is constitutes nearly 90% of public supply. In addition to public supply, groundwater has a number of other uses including agriculture, industry, and food and drink production. It is also vital for maintaining river flows especially during dry periods and so is essential for maintaining ecosystem health. Recently, there have been concerns expressed about the potential impacts of shale gas development on groundwater. The UK has abundant shales and clays which are currently the focus of considerable interest and there is active research into their characterisation, resource evaluation and exploitation risks. The British Geological Survey (BGS) is undertaking research to provide information to address some of the environmental concerns related to the potential impacts of shale gas development on groundwater resources and quality. The aim of much of this initial work is to establish environmental baselines, such as a baseline survey of methane occurrence in groundwater (National methane baseline study) and the spatial relationships between potential sources and groundwater receptors (iHydrogeology project), prior to any shale gas exploration and development. The poster describes these two baseline studies and presents preliminary findings. BGS are currently undertaking a national survey of baseline methane concentrations in groundwater across the UK. This work will enable any potential future changes in methane in groundwater associated with shale gas development to be assessed. Measurements of methane in potable water from the Cretaceous, Jurassic and Triassic carbonate and sandstone aquifers are variable and reveal methane concentrations of up to 500 micrograms per litre, but the mean value is relatively low at documented in the range 2km. The geological modelling process will be presented and discussed

  11. Evidence of the shifting baseline syndrome in ethnobotanical research.

    Science.gov (United States)

    Hanazaki, Natalia; Herbst, Dannieli Firme; Marques, Mel Simionato; Vandebroek, Ina

    2013-11-14

    The shifting baseline syndrome is a concept from ecology that can be analyzed in the context of ethnobotanical research. Evidence of shifting baseline syndrome can be found in studies dealing with intracultural variation of knowledge, when knowledge from different generations is compared and combined with information about changes in the environment and/or natural resources. We reviewed 84 studies published between 1993 and 2012 that made comparisons of ethnobotanical knowledge according to different age classes. After analyzing these studies for evidence of the shifting baseline syndrome (lower knowledge levels in younger generations and mention of declining abundance of local natural resources), we searched within these studies for the use of the expressions "cultural erosion", "loss of knowledge", or "acculturation". The studies focused on different groups of plants (e.g. medicinal plants, foods, plants used for general purposes, or the uses of specific important species). More than half of all 84 studies (57%) mentioned a concern towards cultural erosion or knowledge loss; 54% of the studies showed evidence of the shifting baseline syndrome; and 37% of the studies did not provide any evidence of shifting baselines (intergenerational knowledge differences but no information available about the abundance of natural resources). The general perception of knowledge loss among young people when comparing ethnobotanical repertoires among different age groups should be analyzed with caution. Changes in the landscape or in the abundance of plant resources may be associated with changes in ethnobotanical repertoires held by people of different age groups. Also, the relationship between the availability of resources and current plant use practices rely on a complexity of factors. Fluctuations in these variables can cause changes in the reference (baseline) of different generations and consequently be responsible for differences in intergenerational knowledge. Unraveling

  12. 200-BP-5 operable unit Technical Baseline report

    International Nuclear Information System (INIS)

    Jacques, I.D.; Kent, S.K.

    1991-10-01

    This report supports development of a remedial investigation/feasibility study work plan for the 200-BP-5 operable unit. The report summarizes baseline information for waste sites and unplanned release sites located in the 200-BP-5 operable unit. The sites were investigated by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The investigation consisted of review and evaluation of current and historical Hanford Site reports, drawings, and photographs, and was supplemented with recent inspections of the Hanford Site and employee interviews. No field investigations or sampling were conducted

  13. Survey of Models on Demand, Customer Base-Line and Demand Response and Their Relationships in the Power Market

    OpenAIRE

    Heshmati, Almas

    2012-01-01

    The increasing use of demand-side management as a tool to reliably meet electricity demand at peak time has stimulated interest among researchers, consumers and producer organizations, managers, regulators and policymakers, This research reviews the growing literature on models used to study demand, consumer baseline (CBL) and demand response in the electricity market. After characterizing the general demand models, it reviews consumer baseline based on which further study the demand response...

  14. Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.

    Science.gov (United States)

    Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu

    2018-04-01

    Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.

  15. Framework for ensuring appropriate maintenance of baseline PSA and risk monitor models in a nuclear power plant

    International Nuclear Information System (INIS)

    Vrbanic, I.; Sorman, J.

    2005-01-01

    The necessity of observing both long term and short term risk changes many times imposes the need for a nuclear power plant to have a baseline PSA model to produce an estimate of long term averaged risk and a risk monitor to produce a time-dependent risk curve and/or safety functions status at points in time or over a shorter time period of interest. By nature, a baseline PSA reflects plant systems and operation in terms of average conditions and provides time-invariant quantitative risk metrics. Risk monitor, on the other hand, requires condition-specific modeling to produce a quantitative and/or qualitative estimate of plant's condition-specific risk metrics. While risk monitor is used for computing condition-specific risk metrics over time, a baseline PSA model is needed for variety of other risk oriented applications, such as assessments of proposed design modifications or risk ranking of equipment. Having in mind their importance and roles, it is essential that both models, i.e. baseline PSA model and risk monitor are maintained in the way that they represent, as accurately as practically achievable, the actual plant status (e.g. systems' design and plant's procedures in effect) and its history (e.g. numbers of equipment failures and demands that influence relevant PSA parameters). Paper discusses the requirements for appropriate maintenance of plant's baseline PSA model and risk monitor model and presents the framework for plant's engineering and administrative procedures that would ensure they are met. (author)

  16. Development of a Soil Organic Carbon Baseline for Otjozondjupa, Namibia

    NARCIS (Netherlands)

    Nijbroek, R.; Kempen, B.; Mutua, J.; Soderstrom, M.; Piikki, K.; Hengari, S.; Andreas, A.

    2017-01-01

    Land Degradation Neutrality (LDN) has been piloted in 14 countries and will be scaled up to over 120 countries. As a LDN pilot country, Namibia developed sub-national LDN baselines in Otjozondjupa Region. In addition to the three LDN indicators (soil organic carbon, land productivity and land cover

  17. Automated baseline change detection phase I. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    The Automated Baseline Change Detection (ABCD) project is supported by the DOE Morgantown Energy Technology Center (METC) as part of its ER&WM cross-cutting technology program in robotics. Phase 1 of the Automated Baseline Change Detection project is summarized in this topical report. The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrel and on feature recognition in images. In support of this primary objective, there are secondary objectives to determine DOE operational inspection requirements and DOE system fielding requirements.

  18. Abstract: Notes from the Field: Establishing Baseline Data for ...

    African Journals Online (AJOL)

    Abstract: Notes from the Field: Establishing Baseline Data for Pressure Ulcers in a Rwandan Intensive Care Unit. Gedeon Mutabazi, Jessie Silver. Abstract. Abstract. Background Pressure ulcers are a common iatrogenic medical problem. Pressure ulcers increase the morbidity and mortality of hospitalized patients as well as ...

  19. Effect of computer game playing on baseline laparoscopic simulator skills.

    Science.gov (United States)

    Halvorsen, Fredrik H; Cvancarova, Milada; Fosse, Erik; Mjåland, Odd

    2013-08-01

    Studies examining the possible association between computer game playing and laparoscopic performance in general have yielded conflicting results and neither has a relationship between computer game playing and baseline performance on laparoscopic simulators been established. The aim of this study was to examine the possible association between previous and present computer game playing and baseline performance on a virtual reality laparoscopic performance in a sample of potential future medical students. The participating students completed a questionnaire covering the weekly amount and type of computer game playing activity during the previous year and 3 years ago. They then performed 2 repetitions of 2 tasks ("gallbladder dissection" and "traverse tube") on a virtual reality laparoscopic simulator. Performance on the simulator were then analyzed for association to their computer game experience. Local high school, Norway. Forty-eight students from 2 high school classes volunteered to participate in the study. No association between prior and present computer game playing and baseline performance was found. The results were similar both for prior and present action game playing and prior and present computer game playing in general. Our results indicate that prior and present computer game playing may not affect baseline performance in a virtual reality simulator.

  20. ecotaxonomic baseline evaluation of the plant species in a ...

    African Journals Online (AJOL)

    Admin

    plant species of medicinal and other economic values. The investigation was ... A total of 41 and 24 representative ... INTRODUCTION. Baseline .... at 100m interval, involving a total of 15 sampling locations .... explained by factors such as climate, productivity and ... encouraging the: Maintenance of traditional tree species.

  1. Baseline design of an OTEC pilot plantship. Volume C. Specifications

    Energy Technology Data Exchange (ETDEWEB)

    Glosten, L. R.; Bringloe, Thomas; Soracco, Dave; Fenstermacher, Earl; Magura, Donald; Sander, Olof; Richards, Dennis; Seward, Jerry

    1979-05-01

    Volume C is part of a three-volume report that presents a baseline engineering design of an Ocean Thermal Energy Conversion (OTEC) plantship. This volume provides the specifications for the hull, cold-water pipe, ship outfitting and machinery, OTEC power system, electrical system, and folded-tube heat exchangers.

  2. Technical Baseline Summary Description for the Tank Farm Contractor

    International Nuclear Information System (INIS)

    TEDESCHI, A.R.

    2000-01-01

    This document is a revision of the document titled above, summarizing the technical baseline of the Tank Farm Contractor. It is one of several documents prepared by CH2M HILL Hanford Group, Inc. to support the U.S. Department of Energy Office of River Protection Tank Waste Retrieval and Disposal Mission at Hanford

  3. Delta Healthy Sprouts: Participants' Diet and Food Environment at Baseline

    Science.gov (United States)

    Local food environments influence the nutrition and health of area residents. This baseline analysis focuses on the food environments of women who participated in the Delta Healthy Sprouts project, a randomized, controlled, comparative trial designed to test the efficacy of two Maternal, Infant, an...

  4. 48 CFR 34.202 - Integrated Baseline Reviews.

    Science.gov (United States)

    2010-10-01

    ... or contractor, and the Government, of the— (1) Ability of the project's technical plan to achieve the... successfully achieve the project schedule objectives; (3) Ability of the Performance Measurement Baseline (PMB... SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION Earned Value Management System 34.202...

  5. Baseline Radioactivity Measurements In The Vicinity Of A Gold ...

    African Journals Online (AJOL)

    Western Region, Ghana) to obtain baseline radioactivity data prior to the installation of Cs-137 nuclear density gauges for quality control measure-ment of the density of slurry in the pipelines at the plant. A survey meter, gamma spectrometry and ...

  6. Automated baseline change detection phase I. Final report

    International Nuclear Information System (INIS)

    1995-12-01

    The Automated Baseline Change Detection (ABCD) project is supported by the DOE Morgantown Energy Technology Center (METC) as part of its ER ampersand WM cross-cutting technology program in robotics. Phase 1 of the Automated Baseline Change Detection project is summarized in this topical report. The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrel and on feature recognition in images. In support of this primary objective, there are secondary objectives to determine DOE operational inspection requirements and DOE system fielding requirements

  7. Ecotaxonmic baseline evaluation of the plant species in a ...

    African Journals Online (AJOL)

    The survey of the flora composition of an ecosystem is important in several environmental baseline studies. An ecotaxonomic assessment was carried out in Ase-Ndoni proposed Rivgas Refinery project site in other to find out the plant species of medicinal and other economic values. The investigation was carried out to ...

  8. How to deal with cost differences at baseline

    NARCIS (Netherlands)

    Van Asselt, Antoinette D.I.; Van Mastrigt, Ghislaine A.P.G.; Dirksen, Carmen D.; Arntz, Arnoud; Severens, Johan L.; Kessels, Alfons G.H.

    BACKGROUND: To our knowledge, adjustment for baseline imbalances in costs has never been performed in trial-based cost-effectiveness analyses. METHODS: We used data from a clinical trial performed in the Netherlands comparing two outpatient psychotherapies: schema-focused therapy (SFT) versus

  9. The Dutch CAFE baseline: In or out of line?

    NARCIS (Netherlands)

    Jimmink BA; Folkert RJM; Thomas R; Beck JP; Eerdt MM van; Elzenga HE; Hoek KW van der; Hoen A; Peek CJ; LED; KMD; NMD; LVM; RIM; LDL

    2004-01-01

    The European Commission is constructing a strategy on air pollution within the Clean Air For Europe (CAFE) programme. This strategy will be based on assessments using the RAINS model for different policy ambitions where the CAFE baseline scenario and control strategies are employed. The Netherlands

  10. Emergency Response Capability Baseline Needs Assessment - Requirements Document

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2016-10-04

    This document was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by LLNL Emergency Management Department Head James Colson. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only addresses emergency response.

  11. IEA Wind Task 26: Offshore Wind Farm Baseline Documentation

    Energy Technology Data Exchange (ETDEWEB)

    Smart, Gavin [Offshore Renewable Energy Catapult, Blyth, Northumberland (United Kingdom); Smith, Aaron [National Renewable Energy Lab. (NREL), Golden, CO (United States); Warner, Ethan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sperstad, Iver Bakken [SINTEF Energy Research, Trondheim (Norway); Prinsen, Bob [Ecofys, Utrecht (Netherlands). TKI Wind Op Zee; Lacal-Arantegui, Roberto [European Commission Joint Research Centre (JRC), Brussels (Belgium)

    2016-06-02

    This document has been produced to provide the definition and rationale for the Baseline Offshore Wind Farm established within IEA Wind Task 26--Cost of Wind Energy. The Baseline has been developed to provide a common starting point for country comparisons and sensitivity analysis on key offshore wind cost and value drivers. The baseline project reflects an approximate average of the characteristics of projects installed between 2012 and 2014, with the project life assumed to be 20 years. The baseline wind farm is located 40 kilometres (km) from construction and operations and maintenance (O&M) ports and from export cable landfall. The wind farm consists of 100 4-megawatt (MW) wind turbines mounted on monopile foundations in an average water depth of 25 metres (m), connected by 33-kilovolt (kV) inter-array cables. The arrays are connected to a single offshore substation (33kV/220kV) mounted on a jacket foundation, with the substation connected via a single 220kV export cable to an onshore substation, 10km from landfall. The wind farm employs a port-based O&M strategy using crew-transfer vessels.

  12. Shifted Baselines Reduce Willingness to Pay for Conservation

    Directory of Open Access Journals (Sweden)

    Loren McClenachan

    2018-02-01

    Full Text Available A loss of memory of past environmental degradation has resulted in shifted baselines, which may result in conservation and restoration goals that are less ambitious than if stakeholders had a full knowledge of ecosystem potential. However, the link between perception of baseline states and support for conservation planning has not been tested empirically. Here, we investigate how perceptions of change in coral reef ecosystems affect stakeholders' willingness to pay (WTP for the establishment of protected areas. Coral reefs are experiencing rapid, global change that is observable by the public, and therefore provide an ideal ecosystem to test links between beliefs about baseline states and willingness to support conservation. Our survey respondents perceived change to coral reef communities across six variables: coral abundance, fish abundance, fish diversity, fish size, sedimentation, and water pollution. Respondants who accurately perceived declines in reef health had significantly higher WTP for protected areas (US $256.80 vs. $102.50 per year, suggesting that shifted baselines may reduce engagement with conservation efforts. If WTP translates to engagement, this suggests that goals for restoration and recovery are likely to be more ambitious if the public is aware of long term change. Therefore, communicating the scope and depth of environmental problems is essential in engaging the public in conservation.

  13. Microbunch preserving in-line system for an APPLE II helical radiator at the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL Project Team, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-05-15

    In a previous work we proposed a scheme for polarization control at the LCLS baseline, which exploited the microbunching from the planar undulator. After the baseline undulator, the electron beam is transported through a drift by a FODO focusing system, and through a short helical radiator. The microbunching structure can be preserved, and intense coherent radiation is emitted in the helical undulator at fundamental harmonic. The driving idea of this proposal is that the background linearly-polarized radiation from the baseline undulator is suppressed by spatial filtering. Filtering is achieved by letting radiation and electron beam through Be slits upstream of the helical radiator, where the radiation spot size is about ten times larger than the electron beam transverse size. Several changes considered in the present paper were made to improve the previous design. Slits are now placed immediately behind the helical radiator. The advantage is that the electron beam can be spoiled by the slits, and narrower slits width can be used for spatial filtering. Due to this fundamental reason, the present setup is shorter than the previous one. The helical radiator is now placed immediately behind the SHAB undulator. It is thus sufficient to use the existing FODO focusing system of the SHAB undulator for transporting themodulated electron beam. This paper presents complete GENESIS code calculations for the new design, starting from the baseline undulator entrance up to the helical radiator exit including the modulated electron beam transport by the SHAB FODO focusing system. (orig.)

  14. Microbunch preserving in-line system for an APPLE II helical radiator at the LCLS baseline

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-05-01

    In a previous work we proposed a scheme for polarization control at the LCLS baseline, which exploited the microbunching from the planar undulator. After the baseline undulator, the electron beam is transported through a drift by a FODO focusing system, and through a short helical radiator. The microbunching structure can be preserved, and intense coherent radiation is emitted in the helical undulator at fundamental harmonic. The driving idea of this proposal is that the background linearly-polarized radiation from the baseline undulator is suppressed by spatial filtering. Filtering is achieved by letting radiation and electron beam through Be slits upstream of the helical radiator, where the radiation spot size is about ten times larger than the electron beam transverse size. Several changes considered in the present paper were made to improve the previous design. Slits are now placed immediately behind the helical radiator. The advantage is that the electron beam can be spoiled by the slits, and narrower slits width can be used for spatial filtering. Due to this fundamental reason, the present setup is shorter than the previous one. The helical radiator is now placed immediately behind the SHAB undulator. It is thus sufficient to use the existing FODO focusing system of the SHAB undulator for transporting themodulated electron beam. This paper presents complete GENESIS code calculations for the new design, starting from the baseline undulator entrance up to the helical radiator exit including the modulated electron beam transport by the SHAB FODO focusing system. (orig.)

  15. Leveraging probabilistic peak detection to estimate baseline drift in complex chromatographic samples.

    Science.gov (United States)

    Lopatka, Martin; Barcaru, Andrei; Sjerps, Marjan J; Vivó-Truyols, Gabriel

    2016-01-29

    Accurate analysis of chromatographic data often requires the removal of baseline drift. A frequently employed strategy strives to determine asymmetric weights in order to fit a baseline model by regression. Unfortunately, chromatograms characterized by a very high peak saturation pose a significant challenge to such algorithms. In addition, a low signal-to-noise ratio (i.e. s/npeak detection algorithm. A posterior probability of being affected by a peak is computed for each point in the chromatogram, leading to a set of weights that allow non-iterative calculation of a baseline estimate. For extremely saturated chromatograms, the peak weighted (PW) method demonstrates notable improvement compared to the other methods examined. However, in chromatograms characterized by low-noise and well-resolved peaks, the asymmetric least squares (ALS) and the more sophisticated Mixture Model (MM) approaches achieve superior results in significantly less time. We evaluate the performance of these three baseline correction methods over a range of chromatographic conditions to demonstrate the cases in which each method is most appropriate. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. A method to establish seismic noise baselines for automated station assessment

    Science.gov (United States)

    McNamara, D.E.; Hutt, C.R.; Gee, L.S.; Benz, H.M.; Buland, R.P.

    2009-01-01

    We present a method for quantifying station noise baselines and characterizing the spectral shape of out-of-nominal noise sources. Our intent is to automate this method in order to ensure that only the highest-quality data are used in rapid earthquake products at NEIC. In addition, the station noise baselines provide a valuable tool to support the quality control of GSN and ANSS backbone data and metadata. The procedures addressed here are currently in development at the NEIC, and work is underway to understand how quickly changes from nominal can be observed and used within the NEIC processing framework. The spectral methods and software used to compute station baselines and described herein (PQLX) can be useful to both permanent and portable seismic stations operators. Applications include: general seismic station and data quality control (QC), evaluation of instrument responses, assessment of near real-time communication system performance, characterization of site cultural noise conditions, and evaluation of sensor vault design, as well as assessment of gross network capabilities (McNamara et al. 2005). Future PQLX development plans include incorporating station baselines for automated QC methods and automating station status report generation and notification based on user-defined QC parameters. The PQLX software is available through the USGS (http://earthquake. usgs.gov/research/software/pqlx.php) and IRIS (http://www.iris.edu/software/ pqlx/).

  17. Analysis of factors affecting baseline SF-36 Mental Component Summary in Adult Spinal Deformity and its impact on surgical outcomes.

    Science.gov (United States)

    Mmopelwa, Tiro; Ayhan, Selim; Yuksel, Selcen; Nabiyev, Vugar; Niyazi, Asli; Pellise, Ferran; Alanay, Ahmet; Sanchez Perez Grueso, Francisco Javier; Kleinstuck, Frank; Obeid, Ibrahim; Acaroglu, Emre

    2018-03-01

    To identify the factors that affect SF-36 mental component summary (MCS) in patients with adult spinal deformity (ASD) at the time of presentation, and to analyse the effect of SF-36 MCS on clinical outcomes in surgically treated patients. Prospectively collected data from a multicentric ASD database was analysed for baseline parameters. Then, the same database for surgically treated patients with a minimum of 1-year follow-up was analysed to see the effect of baseline SF-36 MCS on treatment results. A clinically useful SF-36 MCS was determined by ROC Curve analysis. A total of 229 patients with the baseline parameters were analysed. A strong correlation between SF-36 MCS and SRS-22, ODI, gender, and diagnosis were found (p baseline SF-36 MCS (p baseline SF-36 MCS in an ASD population are other HRQOL parameters such as SRS-22 and ODI as well as the baseline thoracic kyphosis and gender. This study has also demonstrated that baseline SF-36 MCS does not necessarily have any effect on the treatment results by surgery as assessed by SRS-22 or ODI. Level III, prognostic study. Copyright © 2018 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  18. Developmental pathways of fitness, and not baseline, predict fitness status at the end of childhood

    OpenAIRE

    Rodrigues, Luis Paulo; Stodden, David F.; Lopes, Vítor P.

    2013-01-01

    It is generally described that children fitness levels increase along childhood. Complementary to this idea is the notion that the tracking of children’s fitness is good to moderate during this developmental time, and that baseline (initial values) of fitness are determinant on fitness development. The importance of developmental pathways has been recently reinforced by a theoretical argument that predicts that healthy lifestyle trajectories will evolve through either a positive or n...

  19. Baseline series fragrance markers fail to predict contact allergy.

    Science.gov (United States)

    Mann, Jack; McFadden, John P; White, Jonathan M L; White, Ian R; Banerjee, Piu

    2014-05-01

    Negative patch test results with fragrance allergy markers in the European baseline series do not always predict a negative reaction to individual fragrance substances. To determine the frequencies of positive test reactions to the 26 fragrance substances for which labelling is mandatory in the EU, and how effectively reactions to fragrance markers in the baseline series predict positive reactions to the fragrance substances that are labelled. The records of 1951 eczema patients, routinely tested with the labelled fragrance substances and with an extended European baseline series in 2011 and 2012, were retrospectively reviewed. Two hundred and eighty-one (14.4%) (71.2% females) reacted to one or more allergens from the labelled-fragrance substance series and/or a fragrance marker from the European baseline series. The allergens that were positive with the greatest frequencies were cinnamyl alcohol (48; 2.46%), Evernia furfuracea (44; 2.26%), and isoeugenol (40; 2.05%). Of the 203 patients who reacted to any of the 26 fragrances in the labelled-fragrance substance series, only 117 (57.6%) also reacted to a fragrance marker in the baseline series. One hundred and seven (52.7%) reacted to either fragrance mix I or fragrance mix II, 28 (13.8%) reacted to Myroxylon pereirae, and 13 (6.4%) reacted to hydroxyisohexyl 3-cyclohexene carboxaldehyde. These findings confirm that the standard fragrance markers fail to identify patients with contact allergies to the 26 fragrances. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  1. Methylphenidate during early consolidation affects long-term associative memory retrieval depending on baseline catecholamines.

    Science.gov (United States)

    Wagner, Isabella C; van Buuren, Mariët; Bovy, Leonore; Morris, Richard G; Fernández, Guillén

    2017-02-01

    Synaptic memory consolidation is thought to rely on catecholaminergic signaling. Eventually, it is followed by systems consolidation, which embeds memories in a neocortical network. Although this sequence was demonstrated in rodents, it is unclear how catecholamines affect memory consolidation in humans. Here, we tested the effects of catecholaminergic modulation on synaptic and subsequent systems consolidation. We expected enhanced memory performance and increased neocortical engagement during delayed retrieval. Additionally, we tested if this effect was modulated by individual differences in a cognitive proxy measure of baseline catecholamine synthesis capacity. Fifty-three healthy males underwent a between-subjects, double-blind, placebo-controlled procedure across 2 days. On day 1, subjects studied and retrieved object-location associations and received 20 mg of methylphenidate or placebo. Drug intake was timed so that methylphenidate was expected to affect early consolidation but not encoding or retrieval. Memory was tested again while subjects were scanned three days later. Methylphenidate did not facilitate memory performance, and there was no significant group difference in activation during delayed retrieval. However, memory representations differed between groups depending on baseline catecholamines. The placebo group showed increased activation in occipito-temporal regions but decreased connectivity with the hippocampus, associated with lower baseline catecholamine synthesis capacity. The methylphenidate group showed stronger activation in the postcentral gyrus, associated with higher baseline catecholamine synthesis capacity. Altogether, methylphenidate during early consolidation did not foster long-term memory performance, but it affected retrieval-related neural processes depending on individual levels of baseline catecholamines.

  2. Effect of Enamel Caries Lesion Baseline Severity on Fluoride Dose-Response

    Directory of Open Access Journals (Sweden)

    Frank Lippert

    2017-01-01

    Full Text Available This study aimed to investigate the effect of enamel caries lesion baseline severity on fluoride dose-response under pH cycling conditions. Early caries lesions were created in human enamel specimens at four different severities (8, 16, 24, and 36 h. Lesions were allocated to treatment groups (0, 83, and 367 ppm fluoride as sodium fluoride based on Vickers surface microhardness (VHN and pH cycled for 5 d. The cycling model comprised 3 × 1 min fluoride treatments sandwiched between 2 × 60 min demineralization challenges with specimens stored in artificial saliva in between. VHN was measured again and changes versus lesion baseline were calculated (ΔVHN. Data were analyzed using two-way ANOVA (p<0.05. Increased demineralization times led to increased surface softening. The lesion severity×fluoride concentration interaction was significant (p<0.001. Fluoride dose-response was observed in all groups. Lesions initially demineralized for 16 and 8 h showed similar overall rehardening (ΔVHN and more than 24 and 36 h lesions, which were similar. The 8 h lesions showed the greatest fluoride response differential (367 versus 0 ppm F which diminished with increasing lesion baseline severity. The extent of rehardening as a result of the 0 ppm F treatment increased with increasing lesion baseline severity, whereas it decreased for the fluoride treatments. In conclusion, lesion baseline severity impacts the extent of the fluoride dose-response.

  3. Relationship between visual field progression and baseline refraction in primary open-angle glaucoma.

    Science.gov (United States)

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Umeda, Yuzo; Shiraga, Fumio

    2016-01-01

    To analyze the relationship between visual field (VF) progression and baseline refraction in Japanese patients with primary open-angle glaucoma (POAG) including normal-tension glaucoma. In this retrospective study, the subjects were patients with POAG who had undergone VF tests at least ten times with a Humphrey Field Analyzer (Swedish interactive thresholding algorithm standard, Central 30-2 program). VF progression was defined as a significantly negative value of mean deviation (MD) slope at the final VF test. Multivariate logistic regression models were applied to detect an association between MD slope deterioration and baseline refraction. A total of 156 eyes of 156 patients were included in this analysis. Significant deterioration of MD slope was observed in 70 eyes of 70 patients (44.9%), whereas no significant deterioration was evident in 86 eyes of 86 patients (55.1%). The eyes with VF progression had significantly higher baseline refraction compared to those without apparent VF progression (-1.9±3.8 diopter [D] vs -3.5±3.4 D, P=0.0048) (mean ± standard deviation). When subject eyes were classified into four groups by the level of baseline refraction applying spherical equivalent (SE): no myopia (SE > -1D), mild myopia (-1D ≥ SE > -3D), moderate myopia (-3D ≥ SE > -6D), and severe myopia (-6D ≥ SE), the Cochran-Armitage trend analysis showed a decreasing trend in the proportion of MD slope deterioration with increasing severity of myopia (P=0.0002). The multivariate analysis revealed that baseline refraction (P=0.0108, odds ratio [OR]: 1.13, 95% confidence interval [CI]: 1.03-1.25) and intraocular pressure reduction rate (P=0.0150, OR: 0.97, 95% CI: 0.94-0.99) had a significant association with MD slope deterioration. In the current analysis of Japanese patients with POAG, baseline refraction was a factor significantly associated with MD slope deterioration as well as intraocular pressure reduction rate. When baseline refraction was classified into

  4. Factors Contributing to Disparities in Baseline Neurocognitive Performance and Concussion Symptom Scores Between Black and White Collegiate Athletes.

    Science.gov (United States)

    Wallace, Jessica; Covassin, Tracey; Moran, Ryan; Deitrick, Jamie McAllister

    2017-11-02

    National Collegiate Athletic Association (NCAA) concussion guidelines state that all NCAA athletes must have a concussion baseline test prior to commencing their competitive season. To date, little research has examined potential racial differences on baseline neurocognitive performance among NCAA athletes. The purpose of this study was to investigate differences between Black and White collegiate athletes on baseline neurocognitive performance and self-reported symptoms. A total of 597 collegiate athletes (400 White, 197 Black) participated in this study. Athletes self-reported their race on the demographic section of their pre-participation physical examination and were administered the Immediate Post-Concussion Assessment and Cognitive Test (ImPACT) neurocognitive battery in a supervised, quiet room. Controlling for sex, data were analyzed using separate one-way analyses of covariance (ANCOVAs) on symptom score, verbal and visual memory, visual motor processing speed, and reaction time composite scores. Results revealed significant differences between White and Black athletes on baseline symptom score (F (1,542)  = 5.82, p = .01), visual motor processing speed (F (1,542)  = 14.89, p baseline visual motor processing speed and reaction time. Black athletes reported higher baseline symptom scores compared to Whites. There was no statistical difference between race on verbal memory (p = .08) and that on visual memory (p = .06). Black athletes demonstrated disparities on some neurocognitive measures at baseline. These results suggest capturing an individual baseline on each athlete, as normative data comparisons may be inappropriate for athletes of a racial minority.

  5. Long-term sea surface temperature baselines - time series, spatial covariation and implications for biological processes

    DEFF Research Database (Denmark)

    MacKenzie, Brian; Schiedek, D.

    2007-01-01

    to 2 years. These differences suggest that spatial variations in physical oceanographic phenomena and sampling heterogeneities associated with opportunistic sampling could affect perceptions of biological responses to temperature fluctuations. The documentation that the coastally measured temperatures...... questions at large spatial scales, such as the response of species distributions and phenologies to climate change. In this study we investigate the spatial synchrony of long-term sea surface temperatures in the North Sea-Baltic Sea region as measured daily at four coastal sites (Marsdiep, Netherlands...... at coastal sites co-varied strongly with each other and with opportunistically measured offshore temperatures despite separation distances between measuring locations of 20-1200 km. This covariance is probably due to the influence of large-scale atmospheric processes on regional temperatures...

  6. K Basin sludge treatment project chemical procesing baseline time diagram study

    International Nuclear Information System (INIS)

    KLIMPER, S.C.

    1999-01-01

    This document provides an initial basis for determining the duration of operating steps and the required resources for chemically treating K Basin sludge before transporting it to Tank Farms. It was assumed that all operations would take place within a TPA specified 13-month timeframe

  7. S Plant Aggregate Area Management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document is prepared in support of an Aggregate Area Management Study of S Plant, 200 West Area, at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. It provides a technical baseline of the aggregate area and the results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC). This document is based on review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. This report describes the REDOX facility and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, underground tank farms designed for high-level liquid wastes, and the lines and encasements that connect them

  8. Baseline ecological risk assessment Salmon Site, Lamar County, Mississippi

    International Nuclear Information System (INIS)

    1995-04-01

    The Salmon Site (SS), formerly the Tatum Dome Test Site, located in Mississippi was the site of two nuclear and two gas explosion tests conducted between 1964 and 1970. A consequence of these testing activities is that radionuclides were released into the salt dome, where they are presently contained. During reentry drilling and other site activities, incidental liquid and solid wastes that contained radioactivity were generated, resulting in some soil, ground water and equipment contamination. As part of the remedial investigation effort, a Baseline Ecological Risk Assessment was conducted at the SS. The purpose is to gauge ecological and other environmental impacts attributable to past activities at the former test facility. The results of this facility-specific baseline risk assessment are presented in this document

  9. U-10Mo Baseline Fuel Fabrication Process Description

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Lance R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Arendt, Christina L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dye, Daniel F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clayton, Christopher K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lerchen, Megan E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lombardo, Nicholas J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zacher, Alan H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-09-27

    This document provides a description of the U.S. High Power Research Reactor (USHPRR) low-enriched uranium (LEU) fuel fabrication process. This document is intended to be used in conjunction with the baseline process flow diagram (PFD) presented in Appendix A. The baseline PFD is used to document the fabrication process, communicate gaps in technology or manufacturing capabilities, convey alternatives under consideration, and as the basis for a dynamic simulation model of the fabrication process. The simulation model allows for the assessment of production rates, costs, and manufacturing requirements (manpower, fabrication space, numbers and types of equipment, etc.) throughout the lifecycle of the USHPRR program. This document, along with the accompanying PFD, is updated regularly

  10. NA61/SHINE Data For Long Baseline Neutrino Experiments

    CERN Document Server

    Hälser, Alexis

    2015-01-01

    Accelerator based long baseline neutrino experiments require precise neutrino fl ux predictions to reach their physics goals. These experiments are commonly based on a set of two detectors. At the near detector, cross section measurements are performed and the neutrino fl ux can be observed before oscillation, while at the far detector the signal for neutrino oscillations is studied. An accurate knowledge on hadron production is mandatory in order to predict the neutrino fluxes. The NA61/SHINE facility at the CERN SPS has proven its ability to deliver high quality measurements of hadron production for the long baseline neutrino experiments. In this paper, the latest results from N A61 /SHINE for the neutrino physics programme are reviewed and future plans are presented.

  11. Overview of the Long-Baseline Neutrino Facility cryogenic system

    CERN Document Server

    Montanari, David; Bremer, Johan; Delaney, Michael; Aurelien, Diaz; Doubnik, Roza; Haaf, Kevin; Hentschel, Steve; Norris, Barry; Voirin, Erik

    2017-01-01

    The Deep Underground Neutrino Experiment (DUNE) collaboration is developing a multi-kiloton Long-Baseline neutrino experiment that will be located one mile underground at the Sanford Underground Research Facility (SURF) in Lead, SD. In the present design, detectors will be located inside four cryostats filled with a total of 68,400 ton of ultrapure liquid argon, at the level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The Long-Baseline Neutrino Facility (LBNF) is developing the conventional facilities and cryogenics infrastructure supporting this experiment. The cryogenics system is composed of several sub-systems: External/Infrastructure, Proximity, and Internal cryogenics. It will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution highlights the main features of the LBNF cryogenic system. It presents its performance, functional requirements and modes of operations. It also details the status of the design, ...

  12. Hepatitis C treatment response kinetics and impact of baseline predictors

    DEFF Research Database (Denmark)

    Lindh, M; Arnholm, B; Eilard, A

    2011-01-01

    Summary. The optimal duration of treatment for hepatitis C virus (HCV) infections is highly variable but critical for achieving cure (sustained virological response, SVR). We prospectively investigated the impact of age, fibrosis, baseline viraemia and genotype on the early viral kinetics...... above 400 000 IU/mL were strongly associated with slower second phase declines of HCV RNA. Genotype 2/3 infections responded more rapidly than genotype 1, reaching week 4 negativity (RVR) in 59%vs 22%. We conclude that baseline response predictors such as age, fibrosis and viral load were well reflected...... by the early viral kinetics as assessed by repeated HCV RNA quantifications. The kinetic patterns and the high relapse rate in genotype 2/3 patients without RVR suggest that this group might benefit from treatment durations longer than 24 weeks....

  13. Mercury exposure may suppress baseline corticosterone levels in juvenile birds.

    Science.gov (United States)

    Herring, Garth; Ackerman, Joshua T; Herzog, Mark P

    2012-06-05

    Mercury exposure has been associated with a wide variety of negative reproductive responses in birds, however few studies have examined the potential for chick impairment via the hypothalamic-pituitary-adrenal (HPA) axis. The HPA axis regulates corticosterone levels during periods of stress. We examined the relationship between baseline fecal corticosterone metabolite concentrations and mercury concentrations in down feathers of recently hatched (feathers (decreasing by 45% across the range of observed mercury concentrations) while accounting for stronger positive correlations between corticosterone concentrations and colony nest abundance and date. These results indicate that chronic mercury exposure may suppress baseline corticosterone concentrations in tern chicks and suggests that a juvenile bird's ability to respond to stress may be reduced via the downregulation of the HPA axis.

  14. Decomposition for emission baseline setting in China's electricity sector

    International Nuclear Information System (INIS)

    Steenhof, Paul A.

    2007-01-01

    Decomposition analysis is used to generate carbon dioxide emission baselines in China's electricity sector to the year 2020. This is undertaken from the vantage point of the final consumer of electricity, and therefore considers factors influencing electricity demand, efficiency of generation, sources of energy used for generation purposes, and the effectiveness of transmission and distribution. It is found that since 1980, gains in efficiency of generation have been the most important factor affecting change in the emission intensity of electricity generated. Based upon known energy and economic policy, efficiency gains will continue to contribute to reductions in the emission intensity of electricity generated, however, fuel shifts to natural gas and increases in nuclear generation will further these trends into the future. The analysis confirms other sources in the literature that decomposition is an appropriate technique available for baseline construction, thereby suitable for the emerging carbon market and its related mechanisms

  15. Baseline ecological risk assessment Salmon Site, Lamar County, Mississippi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    The Salmon Site (SS), formerly the Tatum Dome Test Site, located in Mississippi was the site of two nuclear and two gas explosion tests conducted between 1964 and 1970. A consequence of these testing activities is that radionuclides were released into the salt dome, where they are presently contained. During reentry drilling and other site activities, incidental liquid and solid wastes that contained radioactivity were generated, resulting in some soil, ground water and equipment contamination. As part of the remedial investigation effort, a Baseline Ecological Risk Assessment was conducted at the SS. The purpose is to gauge ecological and other environmental impacts attributable to past activities at the former test facility. The results of this facility-specific baseline risk assessment are presented in this document.

  16. Technical baseline description for in situ vitrification laboratory test equipment

    International Nuclear Information System (INIS)

    Beard, K.V.; Bonnenberg, R.W.; Watson, L.R.

    1991-09-01

    IN situ vitrification (ISV) has been identified as possible waste treatment technology. ISV was developed by Pacific Northwest Laboratory (PNL), Richland, Washington, as a thermal treatment process to treat contaminated soils in place. The process, which electrically melts and dissolves soils and associated inorganic materials, simultaneously destroys and/or removes organic contaminants while incorporating inorganic contaminants into a stable, glass-like residual product. This Technical Baseline Description has been prepared to provide high level descriptions of the design of the Laboratory Test model, including all design modifications and safety improvements made to data. Furthermore, the Technical Baseline Description provides a basic overview of the interface documents for configuration management, program management interfaces, safety, quality, and security requirements. 8 figs

  17. Development of a Soil Organic Carbon Baseline for Otjozondjupa, Namibia

    OpenAIRE

    Nijbroek, R.; Kempen, B.; Mutua, J.; Soderstrom, M.; Piikki, K.; Hengari, S.; Andreas, A.

    2017-01-01

    Land Degradation Neutrality (LDN) has been piloted in 14 countries and will be scaled up to over 120 countries. As a LDN pilot country, Namibia developed sub-national LDN baselines in Otjozondjupa Region. In addition to the three LDN indicators (soil organic carbon, land productivity and land cover change), Namibia also regards bush encroachment as an important form of land degradation. We collected 219 soil profiles and used Random Forest modelling to develop the soil organic carbon stock ba...

  18. Logistics Operations Management Center: Maintenance Support Baseline (LOMC-MSB)

    Science.gov (United States)

    Kurrus, R.; Stump, F.

    1995-01-01

    The Logistics Operations Management Center Maintenance Support Baseline is defined. A historical record of systems, applied to and deleted from, designs in support of future management and/or technical analysis is provided. All Flight elements, Ground Support Equipment, Facility Systems and Equipment and Test Support Equipment for which LOMC has responsibilities at Kennedy Space Center and other locations are listed. International Space Station Alpha Program documentation is supplemented. The responsibility of the Space Station Launch Site Support Office is established.

  19. Baseline descriptions for LWR spent fuel storage, handling, and transportation

    International Nuclear Information System (INIS)

    Moyer, J.W.; Sonnier, C.S.

    1978-04-01

    Baseline descriptions for the storage, handling, and transportation of reactor spent fuel are provided. The storage modes described include light water reactor (LWR) pools, away-from-reactor basins, dry surface storage, reprocessing-facility interim storage pools, and deep geologic storage. Land and water transportation are also discussed. This work was sponsored by the Department of Energy/Office of Safeguards and Security as part of the Sandia Laboratories Fixed Facility Physical Protection Program. 45 figs, 4 tables

  20. The optimized baseline project: Reinventing environmental restoration at Hanford

    International Nuclear Information System (INIS)

    Goodenough, J.D.; Janaskie, M.T.; Kleinen, P.J.

    1994-01-01

    The U.S. Department of Energy Richland Operations Office (DOE-RL) is using a strategic planning effort (termed the Optimized Baseline Project) to develop a new approach to the Hanford Environmental Restoration program. This effort seeks to achieve a quantum leap improvement in performance through results oriented prioritization of activities. This effort was conducted in parallel with the renegotiation of the Tri-Party Agreement and provided DOE with an opportunity to propose innovative initiatives to promote cost effectiveness, accelerate progress in the Hanford Environmental Restoration Program and involve stakeholders in the decision-making process. The Optimized Baseline project is an innovative approach to program planning and decision-making in several respects. First, the process is a top down, value driven effort that responds to values held by DOE, the regulatory community and the public. Second, planning is conducted in a way that reinforces the technical management process at Richland, involves the regulatory community in substantive decisions, and includes the public. Third, the Optimized Baseline Project is being conducted as part of a sitewide Hanford initiative to reinvent Government. The planning process used for the Optimized Baseline Project has many potential applications at other sites and in other programs where there is a need to build consensus among diverse, independent groups of stakeholders and decisionmakers. The project has successfully developed and demonstrated an innovative approach to program planning that accelerates the pace of cleanup, involves the regulators as partners with DOE in priority setting, and builds public understanding and support for the program through meaningful opportunities for involvement

  1. Baseline descriptions for LWR spent fuel storage, handling, and transportation

    Energy Technology Data Exchange (ETDEWEB)

    Moyer, J.W.; Sonnier, C.S.

    1978-04-01

    Baseline descriptions for the storage, handling, and transportation of reactor spent fuel are provided. The storage modes described include light water reactor (LWR) pools, away-from-reactor basins, dry surface storage, reprocessing-facility interim storage pools, and deep geologic storage. Land and water transportation are also discussed. This work was sponsored by the Department of Energy/Office of Safeguards and Security as part of the Sandia Laboratories Fixed Facility Physical Protection Program. 45 figs, 4 tables.

  2. Baseline and cognition activated brain SPECT imaging in depression

    International Nuclear Information System (INIS)

    Zhao Jinhua; Lin Xiangtong; Jiang Kaida; Liu Yongchang; Xu Lianqin

    1998-01-01

    Purpose: To evaluate the regional cerebral blood flow (rCBF) abnormalities through the semiquantitative analysis of the baseline and cognition activated rCBF imaging in unmedicated depressed patients. Methods: 27 depressed patients unmedicated by anti-depressants were enrolled. The diagnosis (depression of moderate degree with somatization) was confirmed by the ICD-10 criteria. 15 age matched normal controls were studied under identical conditions. Baseline and cognition activated 99m Tc-ECD SPECT were performed on 21 of the 27 patients with depression and 13 of the 15 normal controls. Baseline 99m Tc-ECD SPECT alone were performed on the rest 6 patients with depression and 2 normal controls. The cognitive activation is achieved by Wisconsin Card Sorting Test (WCST). 1110 MBq of 99m Tc-ECD was administered by intravenous bolus injection 5 minutes after the onset of the WCST. Semi-quantitative analysis was conducted with the 7th, 8th, 9th, 10th, 11th slices of the transaxial imaging. rCBF ratios of every ROI were calculated using the average tissue activity in the region divided by the maximum activity in the cerebellum. Results: 1) The baseline rCBF of left frontal (0.720) and left temporal lobe (0.720) were decreased significantly in depressed patients comparing with those of the control subjects. 2) The activated rCBF of left frontal lobe (0.719) and left temporal lobe (0.690), left parietal lobe (0.701) were decreased evidently than those of the controls. Conclusions: 1) Hypoperfusions of left frontal and left temporal cortexes were identified in patients with depression. 2) The hypoperfusion of left frontal and left temporal cortexes may be the cause of cognition disorder and depressed mood in patients with depression. 3) Cognition activated brain perfusion imaging is helpful for making a more accurate diagnosis of depression

  3. Robotics Collaborative Technology Alliance (RCTA) 2011 Baseline Assessment Experimental Strategy

    Science.gov (United States)

    2011-09-01

    Traversal over different surfaces— climbing stairs , negotiating ditches, etc.—is an inherent mobility concern. The platform capability of moving over...2 design, not run in a factorial manner. a. Goal: To establish a baseline for the height and type of stairs the SUGV is willing to climb . b...bricks to adjust heights of platforms)? (GDRS will handle this.) • Do we want to add something like bags of mulch as steps for the robot to climb or

  4. Baseline Gas Turbine Development Program. Fourteenth quarterly progress report

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, F W; Wagner, C E

    1976-04-30

    Progress is reported for a Baseline Gas Turbine Development Program sponsored by the Heat Engine Systems Branch, Division of Transportation Energy Conservation (TEC) of the Energy Research and Development Administration (ERDA). Structurally, this program is made up of three parts: (1) documentation of the existing automotive gas turbine state-of-the-art; (2) conduction of an extensive component improvement program; and (3) utilization of the improvements in the design, and building of an Upgraded Engine capable of demonstrating program goals.

  5. Vascular Function at Baseline in the Hemodialysis Fistula Maturation Study

    OpenAIRE

    Dember, Laura M.; Imrey, Peter B.; Duess, Mai?Ann; Hamburg, Naomi M.; Larive, Brett; Radeva, Milena; Himmelfarb, Jonathan; Kraiss, Larry W.; Kusek, John W.; Roy?Chaudhury, Prabir; Terry, Christi M.; Vazquez, Miguel A.; Vongpatanasin, Wanpen; Beck, Gerald J.; Vita, Joseph A.

    2016-01-01

    Background End?stage renal disease is accompanied by functional and structural vascular abnormalities. The objective of this study was to characterize vascular function in a large cohort of patients with end?stage renal disease, using noninvasive physiological measurements, and to correlate function with demographic and clinical factors. Methods and Results We analyzed cross?sectional baseline data from the Hemodialysis Fistula Maturation Study, a multicenter prospective observational cohort ...

  6. Wide baseline stereo matching based on double topological relationship consistency

    Science.gov (United States)

    Zou, Xiaohong; Liu, Bin; Song, Xiaoxue; Liu, Yang

    2009-07-01

    Stereo matching is one of the most important branches in computer vision. In this paper, an algorithm is proposed for wide-baseline stereo vision matching. Here, a novel scheme is presented called double topological relationship consistency (DCTR). The combination of double topological configuration includes the consistency of first topological relationship (CFTR) and the consistency of second topological relationship (CSTR). It not only sets up a more advanced model on matching, but discards mismatches by iteratively computing the fitness of the feature matches and overcomes many problems of traditional methods depending on the powerful invariance to changes in the scale, rotation or illumination across large view changes and even occlusions. Experimental examples are shown where the two cameras have been located in very different orientations. Also, epipolar geometry can be recovered using RANSAC by far the most widely method adopted possibly. By the method, we can obtain correspondences with high precision on wide baseline matching problems. Finally, the effectiveness and reliability of this method are demonstrated in wide-baseline experiments on the image pairs.

  7. Item response theory analysis of the mechanics baseline test

    Science.gov (United States)

    Cardamone, Caroline N.; Abbott, Jonathan E.; Rayyan, Saif; Seaton, Daniel T.; Pawl, Andrew; Pritchard, David E.

    2012-02-01

    Item response theory is useful in both the development and evaluation of assessments and in computing standardized measures of student performance. In item response theory, individual parameters (difficulty, discrimination) for each item or question are fit by item response models. These parameters provide a means for evaluating a test and offer a better measure of student skill than a raw test score, because each skill calculation considers not only the number of questions answered correctly, but the individual properties of all questions answered. Here, we present the results from an analysis of the Mechanics Baseline Test given at MIT during 2005-2010. Using the item parameters, we identify questions on the Mechanics Baseline Test that are not effective in discriminating between MIT students of different abilities. We show that a limited subset of the highest quality questions on the Mechanics Baseline Test returns accurate measures of student skill. We compare student skills as determined by item response theory to the more traditional measurement of the raw score and show that a comparable measure of learning gain can be computed.

  8. Localizing gravitational wave sources with single-baseline atom interferometers

    Science.gov (United States)

    Graham, Peter W.; Jung, Sunghoon

    2018-02-01

    Localizing sources on the sky is crucial for realizing the full potential of gravitational waves for astronomy, astrophysics, and cosmology. We show that the midfrequency band, roughly 0.03 to 10 Hz, has significant potential for angular localization. The angular location is measured through the changing Doppler shift as the detector orbits the Sun. This band maximizes the effect since these are the highest frequencies in which sources live for several months. Atom interferometer detectors can observe in the midfrequency band, and even with just a single baseline they can exploit this effect for sensitive angular localization. The single-baseline orbits around the Earth and the Sun, causing it to reorient and change position significantly during the lifetime of the source, and making it similar to having multiple baselines/detectors. For example, atomic detectors could predict the location of upcoming black hole or neutron star merger events with sufficient accuracy to allow optical and other electromagnetic telescopes to observe these events simultaneously. Thus, midband atomic detectors are complementary to other gravitational wave detectors and will help complete the observation of a broad range of the gravitational spectrum.

  9. Effects of ignoring baseline on modeling transitions from intact cognition to dementia.

    Science.gov (United States)

    Yu, Lei; Tyas, Suzanne L; Snowdon, David A; Kryscio, Richard J

    2009-07-01

    This paper evaluates the effect of ignoring baseline when modeling transitions from intact cognition to dementia with mild cognitive impairment (MCI) and global impairment (GI) as intervening cognitive states. Transitions among states are modeled by a discrete-time Markov chain having three transient (intact cognition, MCI, and GI) and two competing absorbing states (death and dementia). Transition probabilities depend on two covariates, age and the presence/absence of an apolipoprotein E-epsilon4 allele, through a multinomial logistic model with shared random effects. Results are illustrated with an application to the Nun Study, a cohort of 678 participants 75+ years of age at baseline and followed longitudinally with up to ten cognitive assessments per nun.

  10. The Effect of Antenna Position Errors on Redundant-Baseline Calibration of HERA

    Science.gov (United States)

    Orosz, Naomi; Dillon, Joshua; Ewall-Wice, Aaron; Parsons, Aaron; HERA Collaboration

    2018-01-01

    HERA (the Hydrogen Epoch of Reionization Array) is a large, highly-redundant radio interferometer in South Africa currently being built out to 350 14-m dishes. Its mission is to probe large scale structure during and prior to the epoch of reionization using the 21 cm hyperfine transition of neutral hydrogen. The array is designed to be calibrated using redundant baselines of known lengths. However, the dishes can deviate from ideal positions, with errors on the order of a few centimeters. This potentially increases foreground contamination of the 21 cm power spectrum in the cleanest part of Fourier space. The calibration algorithm treats groups of baselines that should be redundant, but are not due to position errors, as if they actually are. Accurate, precise calibration is critical because the foreground signals are 100,000 times stronger than the reionization signal. We explain the origin of this effect and discuss weighting strategies to mitigate it.

  11. Baseline prevalence and predictors of liver fibrosis among HIV-positive individuals

    DEFF Research Database (Denmark)

    Matthews, G V; Neuhaus, J; Bhagani, S

    2015-01-01

    OBJECTIVES: Liver disease is increasingly recognized in HIV-positive individuals, even among those without viral hepatitis, partly as a result of the recent availability of noninvasive methods of liver fibrosis assessment. The objective of this substudy is to compare the effects of early versus...... deferred antiretroviral therapy (ART) on liver fibrosis progression. METHODS: Sites in the Strategic Timing of AntiRetroviral Treatment (START) study with access to FibroScan® were invited to participate in the Liver Fibrosis Progression Substudy. All substudy participants underwent FibroScan® at baseline......, and two noninvasive serum algorithms, APRI and FIB-4, were calculated. Demographic and liver-related information was collected for all START participants at baseline. RESULTS: A total of 230 participants were enrolled in the substudy (11.5% with hepatitis B or C virus coinfection), of whom 221 had a valid...

  12. Re-Creating Missing Population Baselines for Pacific Reef Sharks

    Science.gov (United States)

    Nadon, Marc O; Baum, Julia K; Williams, Ivor D; Mcpherson, Jana M; Zgliczynski, Brian J; Richards, Benjamin L; Schroeder, Robert E; Brainard, Russell E

    2012-01-01

    Summary Abstract Sharks and other large predators are scarce on most coral reefs, but studies of their historical ecology provide qualitative evidence that predators were once numerous in these ecosystems. Quantifying density of sharks in the absence of humans (baseline) is, however, hindered by a paucity of pertinent time-series data. Recently researchers have used underwater visual surveys, primarily of limited spatial extent or nonstandard design, to infer negative associations between reef shark abundance and human populations. We analyzed data from 1607 towed-diver surveys (>1 ha transects surveyed by observers towed behind a boat) conducted at 46 reefs in the central-western Pacific Ocean, reefs that included some of the world's most pristine coral reefs. Estimates of shark density from towed-diver surveys were substantially lower (densidad de tiburones en ausencia de humanos (línea de base) es obstaculizada por la falta de datos de series de tiempo pertinentes. Recientemente, los investigadores han utilizado muestreos visuales submarinos, de extensión espacial limitada o de diseño no estándar, para inferir asociaciones negativas entre la abundancia de tiburones de arrecife y las poblaciones humanas. Analizamos datos de 1607 muestreos por remolque de buzos (transectos >1ha muestreados por observadores remolcados por una lancha) realizados en 46 arrecifes en el Océano Pacífico centro-occidental, arrecifes que incluyeron algunos de los más prístinos del mundo. Las estimaciones de densidad de tiburones fue sustancialmente menor (densidad de tiburones de arrecife observados en los muestreos por remolque de buzos y la población humana en modelos y consideramos la influencia de la productividad oceánica primaria, la temperatura de la superficie del mar, la superficie del arrecife y su complejidad física. Utilizamos estos modelos para estimar la densidad de tiburones en ausencia de humanos. Las densidades de Carcharhinus amblyrhynchos, Triaenodon obesus y

  13. A comparison of different ways of including baseline counts in negative binomial models for data from falls prevention trials.

    Science.gov (United States)

    Zheng, Han; Kimber, Alan; Goodwin, Victoria A; Pickering, Ruth M

    2018-01-01

    A common design for a falls prevention trial is to assess falling at baseline, randomize participants into an intervention or control group, and ask them to record the number of falls they experience during a follow-up period of time. This paper addresses how best to include the baseline count in the analysis of the follow-up count of falls in negative binomial (NB) regression. We examine the performance of various approaches in simulated datasets where both counts are generated from a mixed Poisson distribution with shared random subject effect. Including the baseline count after log-transformation as a regressor in NB regression (NB-logged) or as an offset (NB-offset) resulted in greater power than including the untransformed baseline count (NB-unlogged). Cook and Wei's conditional negative binomial (CNB) model replicates the underlying process generating the data. In our motivating dataset, a statistically significant intervention effect resulted from the NB-logged, NB-offset, and CNB models, but not from NB-unlogged, and large, outlying baseline counts were overly influential in NB-unlogged but not in NB-logged. We conclude that there is little to lose by including the log-transformed baseline count in standard NB regression compared to CNB for moderate to larger sized datasets. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Development of an approach to correcting MicroPEM baseline drift.

    Science.gov (United States)

    Zhang, Ting; Chillrud, Steven N; Pitiranggon, Masha; Ross, James; Ji, Junfeng; Yan, Beizhan

    2018-07-01

    Fine particulate matter (PM 2.5 ) is associated with various adverse health outcomes. The MicroPEM (RTI, NC), a miniaturized real-time portable particulate sensor with an integrated filter for collecting particles, has been widely used for personal PM 2.5 exposure assessment. Five-day deployments were targeted on a total of 142 deployments (personal or residential) to obtain real-time PM 2.5 levels from children living in New York City and Baltimore. Among these 142 deployments, 79 applied high-efficiency particulate air (HEPA) filters in the field at the beginning and end of each deployment to adjust the zero level of the nephelometer. However, unacceptable baseline drift was observed in a large fraction (> 40%) of acquisitions in this study even after HEPA correction. This drift issue has been observed in several other studies as well. The purpose of the present study is to develop an algorithm to correct the baseline drift in MicroPEM based on central site ambient data during inactive time periods. A running baseline & gravimetric correction (RBGC) method was developed based on the comparison of MicroPEM readings during inactive periods to ambient PM 2.5 levels provided by fixed monitoring sites and the gravimetric weight of PM 2.5 collected on the MicroPEM filters. The results after RBGC correction were compared with those using HEPA approach and gravimetric correction alone. Seven pairs of duplicate acquisitions were used to validate the RBGC method. The percentages of acquisitions with baseline drift problems were 42%, 53% and 10% for raw, HEPA corrected, and RBGC corrected data, respectively. Pearson correlation analysis of duplicates showed an increase in the coefficient of determination from 0.75 for raw data to 0.97 after RBGC correction. In addition, the slope of the regression line increased from 0.60 for raw data to 1.00 after RBGC correction. The RBGC approach corrected the baseline drift issue associated with MicroPEM data. The algorithm developed

  15. Baseline requirements for assessment of mining impact using biological monitoring

    International Nuclear Information System (INIS)

    Humphrey, C.L.; Dostine, P.L.

    1995-01-01

    Biological monitoring programmes for environmental protection should provide for both early detection of possible adverse effects, and assessment of the ecological significance of these effects. Monitoring techniques are required that include responses sensitive to the impact, that can be subjected to rigorous statistical analysis and for which statistical power is high. Such issues in baseline research of 'what and how to measure?' and 'for how long?' have been the focus of a programme being developed to monitor and assess effects of mining operations on the essentially pristine, freshwater ecosystems of the Alligator Rivers Region (ARR) in tropical northern Australia. Application of the BACIP (Before, After, Control, Impact, Paired differences) design, utilizing a form of temporal replication, to univariate (single species) and multivariate (community) data is described. The BACIP design incorporates data from single control and impact sites. We argue for modification of the design for particular studies conducted in streams, to incorporate additional independent control sites from adjacent catchment. Inferential power, by way of (i) more confidently attributing cause to an observed change and (ii) providing information about the ecological significance of the change, will be enhanced using a modified BACIP design. In highly valued environments such as the ARR, monitoring programmes require application of statistical tests with high power to guarantee that an impact no greater than a prescribed amount has gone undetected. A minimum number of baseline years using the BACIP approach would therefore be required in order to achieve some desired level of statistical power. This paper describes the results of power analyses conducted on 2-5 years (depending upon the technique) of baseline data from streams of the ARR and discuss the implications of these results for management. 44 refs., 1 tab., 3 figs

  16. Baseline Predictors of Missed Visits in the Look AHEAD Study

    Science.gov (United States)

    Fitzpatrick, Stephanie L.; Jeffery, Robert; Johnson, Karen C.; Roche, Cathy C.; Van Dorsten, Brent; Gee, Molly; Johnson, Ruby Ann; Charleston, Jeanne; Dotson, Kathy; Walkup, Michael P.; Hill-Briggs, Felicia; Brancati, Frederick L.

    2013-01-01

    Objective To identify baseline attributes associated with consecutively missed data collection visits during the first 48 months of Look AHEAD—a randomized, controlled trial in 5145 overweight/obese adults with type 2 diabetes designed to determine the long-term health benefits of weight loss achieved by lifestyle change. Design and Methods The analyzed sample consisted of 5016 participants who were alive at month 48 and enrolled at Look AHEAD sites. Demographic, baseline behavior, psychosocial factors, and treatment randomization were included as predictors of missed consecutive visits in proportional hazard models. Results In multivariate Cox proportional hazard models, baseline attributes of participants who missed consecutive visits (n=222) included: younger age ( Hazard Ratio [HR] 1.18 per 5 years younger; 95% Confidence Interval 1.05, 1.30), higher depression score (HR 1.04; 1.01, 1.06), non-married status (HR 1.37; 1.04, 1.82), never self-weighing prior to enrollment (HR 2.01; 1.25, 3.23), and randomization to minimal vs. intensive lifestyle intervention (HR 1.46; 1.11, 1.91). Conclusions Younger age, symptoms of depression, non-married status, never self-weighing, and randomization to minimal intervention were associated with a higher likelihood of missing consecutive data collection visits, even in a high-retention trial like Look AHEAD. Whether modifications to screening or retention efforts targeted to these attributes might enhance long-term retention in behavioral trials requires further investigation. PMID:23996977

  17. The LIFE Cognition Study: design and baseline characteristics

    Science.gov (United States)

    Sink, Kaycee M; Espeland, Mark A; Rushing, Julia; Castro, Cynthia M; Church, Timothy S; Cohen, Ronald; Gill, Thomas M; Henkin, Leora; Jennings, Janine M; Kerwin, Diana R; Manini, Todd M; Myers, Valerie; Pahor, Marco; Reid, Kieran F; Woolard, Nancy; Rapp, Stephen R; Williamson, Jeff D

    2014-01-01

    Observational studies have shown beneficial relationships between exercise and cognitive function. Some clinical trials have also demonstrated improvements in cognitive function in response to moderate–high intensity aerobic exercise; however, these have been limited by relatively small sample sizes and short durations. The Lifestyle Interventions and Independence for Elders (LIFE) Study is the largest and longest randomized controlled clinical trial of physical activity with cognitive outcomes, in older sedentary adults at increased risk for incident mobility disability. One LIFE Study objective is to evaluate the effects of a structured physical activity program on changes in cognitive function and incident all-cause mild cognitive impairment or dementia. Here, we present the design and baseline cognitive data. At baseline, participants completed the modified Mini Mental Status Examination, Hopkins Verbal Learning Test, Digit Symbol Coding, Modified Rey–Osterrieth Complex Figure, and a computerized battery, selected to be sensitive to changes in speed of processing and executive functioning. During follow up, participants completed the same battery, along with the Category Fluency for Animals, Boston Naming, and Trail Making tests. The description of the mild cognitive impairment/dementia adjudication process is presented here. Participants with worse baseline Short Physical Performance Battery scores (prespecified at ≤7) had significantly lower median cognitive test scores compared with those having scores of 8 or 9 with modified Mini Mental Status Examination score of 91 versus (vs) 93, Hopkins Verbal Learning Test delayed recall score of 7.4 vs 7.9, and Digit Symbol Coding score of 45 vs 48, respectively (all P<0.001). The LIFE Study will contribute important information on the effects of a structured physical activity program on cognitive outcomes in sedentary older adults at particular risk for mobility impairment. In addition to its importance in the

  18. TWRS phase I privatization site environmental baseline and characterization plan

    International Nuclear Information System (INIS)

    Shade, J.W.

    1997-01-01

    This document provides a plan to characterize and develop an environmental baseline for the TWRS Phase I Privatization Site before construction begins. A site evaluation study selected the former Grout Disposal Area of the Grout Treatment Facility in the 200 East Area as the TWRS Phase I Demonstration Site. The site is generally clean and has not been used for previous activities other than the GTF. A DQO process was used to develop a Sampling and Analysis Plan that would allow comparison of site conditions during operations and after Phase I ends to the presently existing conditions and provide data for the development of a preoperational monitoring plan

  19. Spectrum from the Proposed BNL Very Long Baseline Neutrino Facility

    CERN Document Server

    Kahn, S A

    2005-01-01

    This paper calculates the neutrino flux that would be seen at the far detector location from the proposed BNL Very Long Baseline Neutrino Facility. The far detector is assumed to be located at an underground facility in South Dakota 2540 km from BNL. The neutrino beam facility uses a 1 MW upgraded AGS to provide an intense proton beam on the target and a magnetic horn to focus the secondary pion beam. The paper will examine the sensitivity of the neutrino flux at the far detector to the positioning of the horn and target so as to establish alignment tolerances for the neutrino system.

  20. Integrated Baseline System (IBS) Version 1.03: Utilities guide

    Energy Technology Data Exchange (ETDEWEB)

    Burford, M.J.; Downing, T.R.; Pottier, M.C.; Schrank, E.E.; Williams, J.R.

    1993-01-01

    The Integrated Baseline System (IBS) is an emergency management planning and analysis tool that was developed under the direction of the Federal Emergency Management Agency (FEMA). This Utilities Guide explains how to operate utility programs that are supplied as a part of the IBS. These utility programs are chiefly for managing and manipulating various kinds of IBS data and system administration files. Many of the utilities are for creating, editing, converting, or displaying map data and other data that are related to geographic location.

  1. Integrated Baseline System (IBS) Version 2.0: Utilities Guide

    Energy Technology Data Exchange (ETDEWEB)

    Burford, M.J.; Downing, T.R.; Williams, J.R. [Pacific Northwest Lab., Richland, WA (United States); Bower, J.C. [Bower Software Services, Kennewick, WA (United States)

    1994-03-01

    The Integrated Baseline System (IBS) is an emergency management planning and analysis tool being developed under the direction of the US Army Nuclear and Chemical Agency. This Utilities Guide explains how you can use the IBS utility programs to manage and manipulate various kinds of IBS data. These programs include utilities for creating, editing, and displaying maps and other data that are referenced to geographic location. The intended audience for this document are chiefly data managers but also system managers and some emergency management planners and analysts.

  2. Baseline review of the U.S. LHC Accelerator project

    International Nuclear Information System (INIS)

    1998-02-01

    The Department of Energy (DOE) Review of the U.S. Large Hadron Collider (LHC) Accelerator project was conducted February 23--26, 1998, at the request of Dr. John R. O'Fallon, Director, Division of High Energy Physics, Office of Energy Research, U.S. DOE. This is the first review of the U.S. LHC Accelerator project. Overall, the Committee found that the U.S. LHC Accelerator project effort is off to a good start and that the proposed scope is very conservative for the funding available. The Committee recommends that the project be initially baselined at a total cost of $110 million, with a scheduled completion data of 2005. The U.S. LHC Accelerator project will supply high technology superconducting magnets for the interaction regions (IRs) and the radio frequency (rf) straight section of the LHC intersecting storage rings. In addition, the project provides the cryogenic support interface boxes to service the magnets and radiation absorbers to protect the IR dipoles and the inner triplet quadrupoles. US scientists will provide support in analyzing some of the detailed aspects of accelerator physics in the two rings. The three laboratories participating in this project are Brookhaven National Laboratory, Fermi National Accelerator Laboratory (Fermilab), and Lawrence Berkeley National Laboratory. The Committee was very impressed by the technical capabilities of the US LHC Accelerator project team. Cost estimates for each subsystem of the US LHC Accelerator project were presented to the Review Committee, with a total cost including contingency of $110 million (then year dollars). The cost estimates were deemed to be conservative. A re-examination of the funding profile, costs, and schedules on a centralized project basis should lead to an increased list of deliverables. The Committee concluded that the proposed scope of US deliverables to CERN can be readily accomplished with the $110 million total cost baseline for the project. The current deliverables should serve as

  3. Organic Contamination Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

    Science.gov (United States)

    Calaway, Michael J.; Allton, J. H.; Allen, C. C.; Burkett, P. J.

    2013-01-01

    Future planned sample return missions to carbon-rich asteroids and Mars in the next two decades will require strict handling and curation protocols as well as new procedures for reducing organic contamination. After the Apollo program, astromaterial collections have mainly been concerned with inorganic contamination [1-4]. However, future isolation containment systems for astromaterials, possibly nitrogen enriched gloveboxes, must be able to reduce organic and inorganic cross-contamination. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs that could be used as a benchmark for future mission designs.

  4. Environmental surveys of the Heidrun field. Supplementary baseline survey 1992

    International Nuclear Information System (INIS)

    Oug, E.; Konieczny, R.M.; Bakke, T.; Lind, K.

    1993-02-01

    The present survey is a re-investigation of the sea bottom sediments at six sites in the Heidrun oil and gas field, May 1992. Petroleum hydrocarbons and heavy metals were at background levels. Compared to the baseline survey in 1988 values of hydrocarbons and barium were decreased. The sediment fauna was sparse with low numbers of species and individuals. Densities were strongly reduced and diversity decreased compared to 1988. There is no indication of anthropogenic factors or other large scale disturbances in the area to explain the faunal changes, which may reflect a large natural variation in the sediment fauna. 22 refs., 16 figs., 35 tabs

  5. Integrated Baseline System (IBS) Version 2.0: Models guide

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-01

    The Integrated Baseline System (IBS) is an emergency management planning and analysis tool being developed under the direction of the US Army Nuclear and Chemical Agency. This Models Guide summarizes the IBS use of several computer models for predicting the results of emergency situations. These include models for predicting dispersion/doses of airborne contaminants, traffic evacuation, explosion effects, heat radiation from a fire, and siren sound transmission. The guide references additional technical documentation on the models when such documentation is available from other sources. The audience for this manual is chiefly emergency management planners and analysts, but also data managers and system managers.

  6. Exploring the potential of short-baseline physics at Fermilab

    Science.gov (United States)

    Miranda, O. G.; Pasquini, Pedro; Tórtola, M.; Valle, J. W. F.

    2018-05-01

    We study the capabilities of the short-baseline neutrino program at Fermilab to probe the unitarity of the lepton mixing matrix. We find the sensitivity to be slightly better than the current one. Motivated by the future DUNE experiment, we have also analyzed the potential of an extra liquid Argon near detector in the LBNF beamline. Adding such a near detector to the DUNE setup will substantially improve the current sensitivity on nonunitarity. This would help to remove C P degeneracies due to the new complex phase present in the neutrino mixing matrix. We also study the sensitivity of our proposed setup to light sterile neutrinos for various configurations.

  7. Project W-320 thermal hydraulic model benchmarking and baselining

    International Nuclear Information System (INIS)

    Sathyanarayana, K.

    1998-01-01

    Project W-320 will be retrieving waste from Tank 241-C-106 and transferring the waste to Tank 241-AY-102. Waste in both tanks must be maintained below applicable thermal limits during and following the waste transfer. Thermal hydraulic process control models will be used for process control of the thermal limits. This report documents the process control models and presents a benchmarking of the models with data from Tanks 241-C-106 and 241-AY-102. Revision 1 of this report will provide a baselining of the models in preparation for the initiation of sluicing

  8. Emergency Response Capability Baseline Needs Assessment Compliance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, John A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-09-16

    This document is the second of a two-part analysis of Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2013 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2009 BNA, the 2012 BNA document, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures.

  9. The Baseline Positron Production and Capture Scheme for CLIC

    CERN Document Server

    Dadoun, Olivier; Lepercq, Pierre; Poirier, Freddy; Variola, Alessandro; Chehab, Robert; Rinolfi, Louis; Vivoli, Alessandro; Strakhovenko, Vladimir; Xu, Chengai

    2010-01-01

    The CLIC study considers the hybrid source using channeling as the baseline for unpolarised positron production. The hybrid source uses a few GeV electron beam impinging on a tungsten crystal target. With the crystal oriented on its axis it results an intense relatively low energy photon beam. The later is then impinging on an amorphous tungsten target producing positrons by e+e− pair creation. Downstream the amorphous target, a capture section based on an adiabatic matching device followed by a 2 GHz Pre- Injector Linac focuses and accelerates the positron beam up to around 200 MeV

  10. Classifying vulnerability to sleep deprivation using baseline measures of psychomotor vigilance.

    Science.gov (United States)

    Patanaik, Amiya; Kwoh, Chee Keong; Chua, Eric C P; Gooley, Joshua J; Chee, Michael W L

    2015-05-01

    To identify measures derived from baseline psychomotor vigilance task (PVT) performance that can reliably predict vulnerability to sleep deprivation. Subjects underwent total sleep deprivation and completed a 10-min PVT every 1-2 h in a controlled laboratory setting. Participants were categorized as vulnerable or resistant to sleep deprivation, based on a median split of lapses that occurred following sleep deprivation. Standard reaction time, drift diffusion model (DDM), and wavelet metrics were derived from PVT response times collected at baseline. A support vector machine model that incorporated maximum relevance and minimum redundancy feature selection and wrapper-based heuristics was used to classify subjects as vulnerable or resistant using rested data. Two academic sleep laboratories. Independent samples of 135 (69 women, age 18 to 25 y), and 45 (3 women, age 22 to 32 y) healthy adults. In both datasets, DDM measures, number of consecutive reaction times that differ by more than 250 ms, and two wavelet features were selected by the model as features predictive of vulnerability to sleep deprivation. Using the best set of features selected in each dataset, classification accuracy was 77% and 82% using fivefold stratified cross-validation, respectively. In both datasets, DDM measures, number of consecutive reaction times that differ by more than 250 ms, and two wavelet features were selected by the model as features predictive of vulnerability to sleep deprivation. Using the best set of features selected in each dataset, classification accuracy was 77% and 82% using fivefold stratified cross-validation, respectively. Despite differences in experimental conditions across studies, drift diffusion model parameters associated reliably with individual differences in performance during total sleep deprivation. These results demonstrate the utility of drift diffusion modeling of baseline performance in estimating vulnerability to psychomotor vigilance decline

  11. Near Detectors based on gas TPCs for neutrino long baseline experiments

    CERN Document Server

    Blondel, A

    2017-01-01

    Time Projection Chambers have been used with success for the T2K ND280 near detector and are proposed for an upgrade of the T2K near detector. High pressure TPCs are also being considered for future long-baseline experiments like Hyper-Kamiokande and DUNE. A High Pressure TPC would be a very sensitive detector for the detailed study of neutrino-nucleus interactions, a limiting factor for extracting the ultimate precision in long baseline experiments. The requirements of TPCs for neutrino detectors are quite specific. We propose here the development of state-of-the-art near detectors based on gas TPC: atmospheric pressure TPCs for T2K-II and a high-pressure TPC for neutrino experiments. The project proposed here benefits from a strong involvement of the European (CERN) members of the T2K collaboration and beyond. It is a strongly synergetic precursor of other projects of near detectors using gas TPCs that are under discussion for the long baseline neutrino projects worldwide. It will help maintain and develop...

  12. Quantification of in vivo 1H magnetic resonance spectroscopy signals with baseline and lineshape estimation

    International Nuclear Information System (INIS)

    Osorio-Garcia, M I; Sima, D M; Van Huffel, S; Nielsen, F U; Dresselaers, T; Himmelreich, U; Van Leuven, F

    2011-01-01

    The in vivo quantification of magnetic resonance spectroscopy (MRS) signals is a method to estimate metabolite concentrations of living tissue. Obtaining reliable concentrations is still a challenge due to the experimental conditions affecting spectral quality. Additionally, lipids and macromolecules overlap with the metabolites of interest, affecting their reliable estimation. In this study, we propose to combine the self-deconvolution lineshape estimation method, which accounts for spectral shape distortions, with two different approaches for taking into account the macromolecular baseline contribution: (a) based on macromolecules and lipids measured in vivo using an inversion recovery technique, and (b) based on the simulation of macromolecular resonances using prior knowledge from a database of inversion recovery signals. The ultimate goal is to measure macromolecular and lipid data only once as described in (a) to create macromolecular and lipid profiles. These profiles then can be used as described in (b) for data measured under the same conditions. The method is evaluated on in vivo 1 H MRS signals at 9.4 T from mouse hippocampus. Results show that better metabolite fits are obtained when lineshape and baseline estimations are simultaneously performed and that baseline estimation based on prior knowledge from macromolecular measured signals can be reliably used to replace time-consuming individual macromolecular and lipid acquisitions

  13. The "Healthy Habits, Healthy Girls" randomized controlled trial for girls: study design, protocol, and baseline results.

    Science.gov (United States)

    Leme, Ana Carolina Barco; Philippi, Sonia Tucunduva

    2015-07-01

    The purpose of this article is to describe the study design, protocol, and baseline results of the "Healthy Habits, Healthy Girls" program. The intervention is being evaluated through a randomized controlled trial in 10 public schools in the city of São Paulo, Brazil. Data on the following variables were collected and assessed at baseline and will be reevaluated at 7 and 12 months: body mass index, waist circumference, dietary intake, nutrition, physical activity, social cognitive mediators, physical activity level, sedentary behaviors, self-rated physical status, and overall self-esteem. According to the baseline results, 32.4% and 23.4% of girls were overweight in the intervention and control groups, respectively, and in both groups a higher percentage failed to meet daily recommendations for moderate and vigorous physical activity and maximum screen time (TV, computer, mobile devices). There were no significant differences between the groups for most of the variables, except age (p = 0.000) and waist circumference (p = 0.014). The study showed a gap in the Brazilian literature on protocols for randomized controlled trials to prevent obesity among youth. The current study may thus be an important initial contribution to the field.

  14. Rapidly shifting environmental baselines among fishers of the Gulf of California

    Science.gov (United States)

    Sáenz-Arroyo, Andrea; Roberts, Callum M; Torre, Jorge; Cariño-Olvera, Micheline; Enríquez-Andrade, Roberto R

    2005-01-01

    Shifting environmental baselines are inter-generational changes in perception of the state of the environment. As one generation replaces another, people's perceptions of what is natural change even to the extent that they no longer believe historical anecdotes of past abundance or size of species. Although widely accepted, this phenomenon has yet to be quantitatively tested. Here we survey three generations of fishers from Mexico's Gulf of California (N=108), where fish populations have declined steeply over the last 60 years, to investigate how far and fast their environmental baselines are shifting. Compared to young fishers, old fishers named five times as many species and four times as many fishing sites as once being abundant/productive but now depleted (Kruskal–Wallis tests, both p<0.001) with no evidence of a slowdown in rates of loss experienced by younger compared to older generations (Kruskal–Wallis test, n.s. in both cases). Old fishers caught up to 25 times as many Gulf grouper Mycteroperca jordani as young fishers on their best ever fishing day (regression r2=0.62, p<0.001). Despite times of plentiful large fish still being within living memory, few young fishers appreciated that large species had ever been common or nearshore sites productive. Such rapid shifts in perception of what is natural help explain why society is tolerant of the creeping loss of biodiversity. They imply a large educational hurdle in efforts to reset expectations and targets for conservation. PMID:16191603

  15. Gender-Specific Differences in Baseline, Peak, and Delta Serum Creatinine: The NACSELD Experience.

    Science.gov (United States)

    O'Leary, Jacqueline G; Wong, Florence; Reddy, K Rajender; Garcia-Tsao, Guadalupe; Kamath, Patrick S; Biggins, Scott W; Fallon, Michael B; Subramanian, Ram M; Maliakkal, B; Thacker, Leroy; Bajaj, Jasmohan S

    2017-03-01

    Women have lower serum creatinine values than men for similar renal function. We aimed to determine the differential effect of baseline, peak, and delta creatinine between genders on outcomes in infected hospitalized cirrhotic patients. North American Consortium for the Study of End-Stage Liver Disease is a 15-center consortium of tertiary care hepatology centers prospectively enrolling infected cirrhotic inpatients. Baseline, peak, and delta creatinine during hospitalization were compared between genders, and their impact on overall survival, transplant-free survival, probability of transplantation, and need for renal replacement therapy (RRT) was analyzed. In total, 532 patients with cirrhosis (males = 59% median admission MELD = 20) had significantly lower median baseline (1.07 vs. 1.30 mg/dL, p creatinine (1.47 vs. 1.59 mg/dL, p = 0.024) in women than men during hospitalization for an infection, but both genders had similar delta creatinine levels (0.30 vs. 0.30 mg/dL, p = 0.957). Thirty-day mortality was similar between genders. RRT was not used more often in women (19 vs. 12%, p = 0.050), and women were 1.8 times more likely than men to receive RRT at the same creatinine (p = 0.028). Both peak and delta creatinine significantly predicted 6-month overall and transplant-free survival (p creatinine. Infected hospitalized cirrhotic women are significantly more likely than men to receive RRT at similar creatinine levels. Gender-specific differences in baseline, peak, and delta creatinine need further investigation to determine whether women need acute kidney injury treatment at lower creatinine thresholds than men.

  16. Unintended cultivation, shifting baselines, and conflict between objectives for fisheries and conservation.

    Science.gov (United States)

    Brown, Christopher J; Trebilco, Rowan

    2014-06-01

    The effects of fisheries on marine ecosystems, and their capacity to drive shifts in ecosystem states, have been widely documented. Less well appreciated is that some commercially valuable species respond positively to fishing-induced ecosystem change and can become important fisheries resources in modified ecosystems. Thus, the ecological effects of one fishery can unintentionally increase the abundance and productivity of other fished species (i.e., cultivate). We reviewed examples of this effect in the peer-reviewed literature. We found 2 underlying ecosystem drivers of the effect: trophic release of prey species when predators are overfished and habitat change. Key ecological, social, and economic conditions required for one fishery to unintentionally cultivate another include strong top-down control of prey by predators, the value of the new fishery, and the capacity of fishers to adapt to a new fishery. These unintended cultivation effects imply strong trade-offs between short-term fishery success and conservation efforts to restore ecosystems toward baseline conditions because goals for fisheries and conservation may be incompatible. Conflicts are likely to be exacerbated if fisheries baselines shift relative to conservation baselines and there is investment in the new fishery. However, in the long-term, restoration toward ecosystem baselines may often benefit both fishery and conservation goals. Unintended cultivation can be identified and predicted using a combination of time-series data, dietary studies, models of food webs, and socioeconomic data. Identifying unintended cultivation is necessary for management to set compatible goals for fisheries and conservation. © 2014 Society for Conservation Biology.

  17. Experimental increase in baseline corticosterone level reduces oxidative damage and enhances innate immune response.

    Directory of Open Access Journals (Sweden)

    Csongor I Vágási

    Full Text Available Glucocorticoid (GC hormones are significant regulators of homeostasis. The physiological effects of GCs critically depend on the time of exposure (short vs. long as well as on their circulating levels (baseline vs. stress-induced. Previous experiments, in which chronic and high elevation of GC levels was induced, indicate that GCs impair both the activity of the immune system and the oxidative balance. Nonetheless, our knowledge on how mildly elevated GC levels, a situation much more common in nature, might influence homeostasis is limited. Therefore, we studied whether an increase in GC level within the baseline range suppresses or enhances condition (body mass, hematocrit and coccidian infestation and physiological state (humoral innate immune system activity and oxidative balance. We implanted captive house sparrows Passer domesticus with either 60 days release corticosterone (CORT or control pellets. CORT-treated birds had elevated baseline CORT levels one week after the implantation, but following this CORT returned to its pre-treatment level and the experimental groups had similar CORT levels one and two months following the implantation. The mass of tail feathers grown during the initial phase of treatment was smaller in treated than in control birds. CORT implantation had a transient negative effect on body mass and hematocrit, but both of these traits resumed the pre-treatment values by one month post-treatment. CORT treatment lowered oxidative damage to lipids (malondialdehyde and enhanced constitutive innate immunity at one week and one month post-implantation. Our findings suggest that a relatively short-term (i.e. few days elevation of baseline CORT might have a positive and stimulatory effect on animal physiology.

  18. The IUGS/IAGC Task Group on Global Geochemical Baselines

    Science.gov (United States)

    Smith, David B.; Wang, Xueqiu; Reeder, Shaun; Demetriades, Alecos

    2012-01-01

    The Task Group on Global Geochemical Baselines, operating under the auspices of both the International Union of Geological Sciences (IUGS) and the International Association of Geochemistry (IAGC), has the long-term goal of establishing a global geochemical database to document the concentration and distribution of chemical elements in the Earth’s surface or near-surface environment. The database and accompanying element distribution maps represent a geochemical baseline against which future human-induced or natural changes to the chemistry of the land surface may be recognized and quantified. In order to accomplish this long-term goal, the activities of the Task Group include: (1) developing partnerships with countries conducting broad-scale geochemical mapping studies; (2) providing consultation and training in the form of workshops and short courses; (3) organizing periodic international symposia to foster communication among the geochemical mapping community; (4) developing criteria for certifying those projects whose data are acceptable in a global geochemical database; (5) acting as a repository for data collected by those projects meeting the criteria for standardization; (6) preparing complete metadata for the certified projects; and (7) preparing, ultimately, a global geochemical database. This paper summarizes the history and accomplishments of the Task Group since its first predecessor project was established in 1988.

  19. On the baseline evolution of automobile fuel economy in Europe

    International Nuclear Information System (INIS)

    Zachariadis, Theodoros

    2006-01-01

    'Business as usual' scenarios in long-term energy forecasts are crucial for scenario-based policy analyses. This article focuses on fuel economy of passenger cars and light trucks, a long-disputed issue with serious implications for worldwide energy use and CO 2 emissions. The current status in Europe is explained and future developments are analysed with the aid of historical data of the last three decades from the United States and Europe. As a result of this analysis, fuel economy values are proposed for use as assumptions in baseline energy/transport scenarios in the 15 'old' European Union Member States. Proposed values are given for new gasoline and diesel cars and for the years 2010, 2020 and 2030. The increasing discrepancy between vehicle fuel consumption measured under test conditions and that in the real world is also considered. One main conclusion is that the European Commission's voluntary agreement with the automobile industry should not be assumed to fully achieve its target under baseline conditions, nor should it be regarded as a major stimulus for autonomous vehicle efficiency improvements after 2010. A second conclusion is that three very recent studies enjoying authority across the EU tend to be overly optimistic as regards the technical progress for conventional and alternative vehicle propulsion technologies under 'business as usual' conditions

  20. NOvA Short-Baseline Tau Neutrino Appearance Search

    Energy Technology Data Exchange (ETDEWEB)

    Keloth, Rijeesh [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexander [Cincinnati U.; Davies, Gavin S [Indiana U.; Suter, Louise [Fermilab; Plunkett, Robert K [Fermilab

    2017-10-01

    Standard three-flavor neutrino oscillations have well explained by a wide range of neutrino experiments. However, the anomalous results, such as electron-antineutrino excess seen by LSND and MiniBooNE do not fit the three-flavor paradigm. This can be explained by an additional fourth flavor sterile neutrino at a larger scale than the existing three flavor neutrinos. The NOvA experiment consists of two finely segmented, liquid scintillator detectors operating 14 .6 mrad off-axis from the NuMI muon-neutrino beam. The Near Detector is located on the Fermilab campus, 1 km from the NuMI target, while the Far Detector is located at Ash River, MN, 810 km from the NuMI target. The NOvA experiment is primarily designed to measure electron-neutrino appearance at the Far Detector using the Near Detector to control systematic uncertainties; however, the Near Detector is well suited for searching for anomalous short-baseline oscillations. This poster will present a novel method for selecting tau neutrino interactions with high purity at the Near Detector using a convolutional neural network. Using this method, the sensitivity to anomalous short-baseline tau-neutrino appearance due to sterile neutrino oscillations will be presented.

  1. Moderate Baseline Vagal Tone Predicts Greater Prosociality in Children

    Science.gov (United States)

    Miller, Jonas G.; Kahle, Sarah; Hastings, Paul D.

    2016-01-01

    Vagal tone is widely believed to be an important physiological aspect of emotion regulation and associated positive behaviors. However, there is inconsistent evidence for relations between children’s baseline vagal tone and their helpful or prosocial responses to others (Hastings & Miller, 2014). Recent work in adults suggests a quadratic association (inverted U-shape curve) between baseline vagal tone and prosociality (Kogan et al., 2014). The present research examined whether this nonlinear association was evident in children. We found consistent evidence for a quadratic relation between vagal tone and prosociality across 3 samples of children using 6 different measures. Compared to low and high vagal tone, moderate vagal tone in early childhood concurrently predicted greater self-reported prosociality (Study 1), observed empathic concern in response to the distress of others and greater generosity toward less fortunate peers (Study 2), and longitudinally predicted greater self-, mother-, and teacher-reported prosociality 5.5 years later in middle childhood (Study 3). Taken together, our findings suggest that moderate vagal tone at rest represents a physiological preparedness or tendency to engage in different forms of prosociality across different contexts. Early moderate vagal tone may reflect an optimal balance of regulation and arousal that helps prepare children to sympathize, comfort, and share with others. PMID:27819463

  2. Baseline Glass Development for Combined Fission Products Waste Streams

    International Nuclear Information System (INIS)

    Crum, Jarrod V.; Billings, Amanda Y.; Lang, Jesse B.; Marra, James C.; Rodriguez, Carmen P.; Ryan, Joseph V.; Vienna, John D.

    2009-01-01

    Borosilicate glass was selected as the baseline technology for immobilization of the Cs/Sr/Ba/Rb (Cs), lanthanide (Ln) and transition metal fission product (TM) waste steams as part of a cost benefit analysis study.(1) Vitrification of the combined waste streams have several advantages, minimization of the number of waste forms, a proven technology, and similarity to waste forms currently accepted for repository disposal. A joint study was undertaken by Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) to develop acceptable glasses for the combined Cs + Ln + TM waste streams (Option 1) and Cs + Ln combined waste streams (Option 2) generated by the AFCI UREX+ set of processes. This study is aimed to develop baseline glasses for both combined waste stream options and identify key waste components and their impact on waste loading. The elemental compositions of the four-corners study were used along with the available separations data to determine the effect of burnup, decay, and separations variability on estimated waste stream compositions.(2-5) Two different components/scenarios were identified that could limit waste loading of the combined Cs + LN + TM waste streams, where as the combined Cs + LN waste stream has no single component that is perceived to limit waste loading. Combined Cs + LN waste stream in a glass waste form will most likely be limited by heat due to the high activity of Cs and Sr isotopes.

  3. New light Higgs boson and short-baseline neutrino anomalies

    Science.gov (United States)

    Asaadi, J.; Church, E.; Guenette, R.; Jones, B. J. P.; Szelc, A. M.

    2018-04-01

    The low-energy excesses observed by the MiniBooNE experiment have, to date, defied a convincing explanation under the standard model even with accommodation for nonzero neutrino mass. In this paper we explore a new oscillation mechanism to explain these anomalies, invoking a light neutrinophilic Higgs boson, conceived to induce a low Dirac neutrino mass in accord with experimental limits. Beam neutrinos forward scattering off of a locally overdense relic neutrino background give rise to a novel matter effect with an energy-specific resonance. An enhanced oscillation around this resonance peak produces flavor transitions which are highly consistent with the MiniBooNE neutrino- and antineutrino-mode data sets. The model provides substantially improved χ2 values beyond either the no-oscillation hypothesis or the more commonly explored 3 +1 sterile neutrino hypothesis. This mechanism would introduce distinctive signatures at each baseline in the upcoming short-baseline neutrino program at Fermilab, presenting opportunities for further exploration.

  4. Eielson Air Force Base OU-1 baseline risk assessment

    International Nuclear Information System (INIS)

    Jarvis, M.T.; Jarvis, T.T.; Van Houten, N.C.; Lewis, R.E.

    1993-09-01

    This Baseline Risk Assessment report is the second volume in a set of three volumes for operable Unit 1 (OU-1). The companion documents contain the Remedial Investigation and the Feasibility Study. Operable Unit 1 (OU-1) is one of several groups of hazardous waste sites located at Eielson Air Force Base (AFB) near Fairbanks, Alaska. The operable units at Eielson are typically characterized by petroleum, oil, lubricant/solvent contamination, and by the presence of organics floating at the water table. In 1989 and 1990, firms under contract to the Air Force conducted field studies to gather information about the extent of chemical contamination in soil, groundwater, and soil air pore space (soil gas) at the site. This report documents the results of a baseline risk assessment, which uses the 1989 and 1991 site characterization database to quantify the potential human health risk associated with past Base industrial activities in the vicinity of OU-1. Background data collected in 1992 were also used in the preparation of this report

  5. 40 CFR 80.1285 - How does a refiner apply for a benzene baseline?

    Science.gov (United States)

    2010-07-01

    ... baseline? 80.1285 Section 80.1285 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (abt) Program § 80.1285 How does a refiner apply for a benzene baseline? (a) A benzene baseline... credits. (b) For U.S. Postal delivery, the benzene baseline application shall be sent to: Attn: MSAT2...

  6. Improving Ambiguity Resolution for Medium Baselines Using Combined GPS and BDS Dual/Triple-Frequency Observations.

    Science.gov (United States)

    Gao, Wang; Gao, Chengfa; Pan, Shuguo; Wang, Denghui; Deng, Jiadong

    2015-10-30

    The regional constellation of the BeiDou navigation satellite system (BDS) has been providing continuous positioning, navigation and timing services since 27 December 2012, covering China and the surrounding area. Real-time kinematic (RTK) positioning with combined BDS and GPS observations is feasible. Besides, all satellites of BDS can transmit triple-frequency signals. Using the advantages of multi-pseudorange and carrier observations from multi-systems and multi-frequencies is expected to be of much benefit for ambiguity resolution (AR). We propose an integrated AR strategy for medium baselines by using the combined GPS and BDS dual/triple-frequency observations. In the method, firstly the extra-wide-lane (EWL) ambiguities of triple-frequency system, i.e., BDS, are determined first. Then the dual-frequency WL ambiguities of BDS and GPS were resolved with the geometry-based model by using the BDS ambiguity-fixed EWL observations. After that, basic (i.e., L1/L2 or B1/B2) ambiguities of BDS and GPS are estimated together with the so-called ionosphere-constrained model, where the ambiguity-fixed WL observations are added to enhance the model strength. During both of the WL and basic AR, a partial ambiguity fixing (PAF) strategy is adopted to weaken the negative influence of new-rising or low-elevation satellites. Experiments were conducted and presented, in which the GPS/BDS dual/triple-frequency data were collected in Nanjing and Zhengzhou of China, with the baseline distance varying from about 28.6 to 51.9 km. The results indicate that, compared to the single triple-frequency BDS system, the combined system can significantly enhance the AR model strength, and thus improve AR performance for medium baselines with a 75.7% reduction of initialization time on average. Besides, more accurate and stable positioning results can also be derived by using the combined GPS/BDS system.

  7. The long-period eccentric orbit of the particle accelerator HD 167971 revealed by long baseline interferometry

    NARCIS (Netherlands)

    De Becker, M.; Sana, H.; Absil, O.; Le Bouquin, J.-B.; Blomme, R.

    2012-01-01

    Using optical long baseline interferometry, we resolved for the first time the two wide components of HD 167971, a candidate hierarchical triple system known to efficiently accelerate particles. Our multi-epoch Very Large Telescope Interferometer observations provide direct evidence for a

  8. Sandia National Laboratories, California proposed CREATE facility environmental baseline survey.

    Energy Technology Data Exchange (ETDEWEB)

    Catechis, Christopher Spyros

    2013-10-01

    Sandia National Laboratories, Environmental Programs completed an environmental baseline survey (EBS) of 12.6 acres located at Sandia National Laboratories/California (SNL/CA) in support of the proposed Collaboration in Research and Engineering for Advanced Technology and Education (CREATE) Facility. The survey area is comprised of several parcels of land within SNL/CA, County of Alameda, California. The survey area is located within T 3S, R 2E, Section 13. The purpose of this EBS is to document the nature, magnitude, and extent of any environmental contamination of the property; identify potential environmental contamination liabilities associated with the property; develop sufficient information to assess the health and safety risks; and ensure adequate protection for human health and the environment related to a specific property.

  9. PUREX Plant aggregate area management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    The PUREX aggregate area is made up of six operable units; 200-PO-1 through 200-PO-6 and consists of liquid and solid waste disposal sites in the vicinity of, and related to, PUREX Plant operations. This report describes PUREX and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches and ditches, ponds, catch tanks, settling tanks, diversion boxes, underground tank farms, and the lines and encasements that connect them. Each waste site in the aggregate area is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. This document provides a technical baseline of the aggregate area and results from an environmental investigation. This document is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. No intrusive field investigations or sampling were conducted

  10. Z plant aggregate area management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    This document was prepared in support of the development of a Aggregate Area Management Study of Z Plant, 200 West Area, at the US Department of Energy (DOE) Hanford Site near Richland, Washington. It provides a technical description and operational history of the aggregate area and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (WHC) which is currently the Waste Site and Facility Research Office, Natural Resources, Bechtel Hanford, Inc. (BHI). It is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. No intrusive field investigations or sampling were conducted in support of this report

  11. Emergency Response Capability Baseline Needs Assessment - Compliance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, John A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-09-01

    This document was prepared by John A. Sharry, LLNL Fire Marshal and Division Leader for Fire Protection and was reviewed by LLNL Emergency Management Department Head, James Colson. This document is the second of a two-part analysis on Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2016 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2016 BNA, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures. The 2013 BNA was approved by NNSA’s Livermore Field Office on January 22, 2014.

  12. Electricity End Uses, Energy Efficiency, and Distributed Energy Resources Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Lisa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Morrow, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Deason, Jeff [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Leventis, Greg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Smith, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Leow, Woei Ling [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Levin, Todd [Argonne National Lab. (ANL), Argonne, IL (United States); Plotkin, Steven [Argonne National Lab. (ANL), Argonne, IL (United States); Zhou, Yan [Oak Ridge Inst. for Science and Education (ORISE), Oak Ridge, TN (United States)

    2017-01-01

    This report was developed by a team of analysts at Lawrence Berkeley National Laboratory, with Argonne National Laboratory contributing the transportation section, and is a DOE EPSA product and part of a series of “baseline” reports intended to inform the second installment of the Quadrennial Energy Review (QER 1.2). QER 1.2 provides a comprehensive review of the nation’s electricity system and cover the current state and key trends related to the electricity system, including generation, transmission, distribution, grid operations and planning, and end use. The baseline reports provide an overview of elements of the electricity system. This report focuses on end uses, electricity consumption, electric energy efficiency, distributed energy resources (DERs) (such as demand response, distributed generation, and distributed storage), and evaluation, measurement, and verification (EM&V) methods for energy efficiency and DERs.

  13. The OPERA Long Baseline Experiment: Status and First Results

    CERN Document Server

    Duchesneau, Dominique

    2008-01-01

    OPERA (Oscillation Project with Emulsion tRacking Apparatus)is an international collaboration between Europe and Asia, aiming to give the first direct proof of tau neutrino appearance in a pure muon neutrino beam, in order to validate the hypothesis for atmospheric neutrino oscillations. The first european long baseline neutrino beam called CNGS is produced at CERN and sent in the direction of the Gran Sasso underground laboratory 730 km away, where the OPERA detector is located. Since 2006 the electronic detector part is fully commissioned and running. Cosmic ray events have been recorded on a regular basis and the first neutrino beam events have been observed in the target elements made of very precise emulsion films and lead sheets during the last run in autumn 2007. This paper reviews the status of the detector, the beam performances, the first results from the neutrino event analysis and the prospects.

  14. OCRWM procedure for reporting software baseline change information

    International Nuclear Information System (INIS)

    1994-07-01

    The purpose of this procedure is to establish a requirement and method for participant organizations to report software baseline change information to the M ampersand O Configuration Management (CM) organization for inclusion in the OCRWM Configuration Information System (CIS). (The requirements for performing software configuration management (SCM) are found in the OCRWM Quality Assurance Requirements and Description (QARD) document and in applicable DOE orders, and not in this procedure.) This procedure provides a linkage between each participant's SCM system and the CIS, which may be accessed for identification, descriptive, and contact information pertaining to software released by a participant. Such information from the CIS will enable retrieval of details and copies of software code and documentation from the participant SCM system

  15. Nonlinear Dynamic Inversion Baseline Control Law: Architecture and Performance Predictions

    Science.gov (United States)

    Miller, Christopher J.

    2011-01-01

    A model reference dynamic inversion control law has been developed to provide a baseline control law for research into adaptive elements and other advanced flight control law components. This controller has been implemented and tested in a hardware-in-the-loop simulation; the simulation results show excellent handling qualities throughout the limited flight envelope. A simple angular momentum formulation was chosen because it can be included in the stability proofs for many basic adaptive theories, such as model reference adaptive control. Many design choices and implementation details reflect the requirements placed on the system by the nonlinear flight environment and the desire to keep the system as basic as possible to simplify the addition of the adaptive elements. Those design choices are explained, along with their predicted impact on the handling qualities.

  16. Detectors for the MINOS long-baseline neutrino oscillation experiment

    International Nuclear Information System (INIS)

    Ayres, D.S.

    1996-01-01

    The MINOS long-baseline experiment will use an intense neutrino beam, generated by Fermilab''s Main Injector accelerator, and 730 km flight path to search for neutrino oscillations. The 10,000 ton MINOS far detector will utilize toroidally magnetized steel plates interleaved with track chambers to reconstruct event topologies and to measure the energies of the muons, hadrons and electromagnetic showers produced by neutrino interactions. The MINOS collaboration is currently developing three alternative technologies for the track chambers: ''Iarocci'' tubes (operated in either limited streamer or saturated proportional mode), RPC''s (with either glass or ABS plates), and scintillator (either liquid or plastic) with wavelength shifting fiber readout. The technology choice will be made in mid 1997 based on the projected performance and cost of the 32,000 m 2 active detector system

  17. Integrated Baseline Bystem (IBS) Version 1.03: Models guide

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    The Integrated Baseline System)(IBS), operated by the Federal Emergency Management Agency (FEMA), is a system of computerized tools for emergency planning and analysis. This document is the models guide for the IBS and explains how to use the emergency related computer models. This document provides information for the experienced system user, and is the primary reference for the computer modeling software supplied with the system. It is designed for emergency managers and planners, and others familiar with the concepts of computer modeling. Although the IBS manual set covers basic and advanced operations, it is not a complete reference document set. Emergency situation modeling software in the IBS is supported by additional technical documents. Some of the other IBS software is commercial software for which more complete documentation is available. The IBS manuals reference such documentation where necessary.

  18. Baseline projections of transportation energy consumption by mode: 1981 update

    Energy Technology Data Exchange (ETDEWEB)

    Millar, M; Bunch, J; Vyas, A; Kaplan, M; Knorr, R; Mendiratta, V; Saricks, C

    1982-04-01

    A comprehensive set of activity and energy-demand projections for each of the major transportation modes and submodes is presented. Projections are developed for a business-as-usual scenario, which provides a benchmark for assessing the effects of potential conservation strategies. This baseline scenario assumes a continuation of present trends, including fuel-efficiency improvements likely to result from current efforts of vehicle manufacturers. Because of anticipated changes in fuel efficiency, fuel price, modal shifts, and a lower-than-historic rate of economic growth, projected growth rates in transportation activity and energy consumption depart from historic patterns. The text discusses the factors responsible for this departure, documents the assumptions and methodologies used to develop the modal projections, and compares the projections with other efforts.

  19. C-018H Pre-Operational Baseline Sampling Plan

    International Nuclear Information System (INIS)

    Guzek, S.J.

    1993-01-01

    The objective of this task is to field characterize and sample the soil at selected locations along the proposed effluent line routes for Project C-018H. The overall purpose of this effort is to meet the proposed plan to discontinue the disposal of contaminated liquids into the Hanford soil column as described by DOE (1987). Detailed information describing proposed transport pipeline route and associated Kaiser Engineers Hanford Company (KEH) preliminary drawings (H288746...755) all inclusive, have been prepared by KEH (1992). The information developed from field monitoring and sampling will be utilized to characterize surface and subsurface soil along the proposed C-018H effluent pipeline and it's associated facilities. Potentially existing contaminant levels may be encountered therefore, soil characterization will provide a construction preoperational baseline reference, develop personnel safety requirements, and determine the need for any changes in the proposed routes prior to construction of the pipeline

  20. Energy reconstruction in the long-baseline neutrino experiment.

    Science.gov (United States)

    Mosel, U; Lalakulich, O; Gallmeister, K

    2014-04-18

    The Long-Baseline Neutrino Experiment aims at measuring fundamental physical parameters to high precision and exploring physics beyond the standard model. Nuclear targets introduce complications towards that aim. We investigate the uncertainties in the energy reconstruction, based on quasielastic scattering relations, due to nuclear effects. The reconstructed event distributions as a function of energy tend to be smeared out and shifted by several 100 MeV in their oscillatory structure if standard event selection is used. We show that a more restrictive experimental event selection offers the possibility to reach the accuracy needed for a determination of the mass ordering and the CP-violating phase. Quasielastic-based energy reconstruction could thus be a viable alternative to the calorimetric reconstruction also at higher energies.

  1. Waste Assessment Baseline for the IPOC Second Floor, West Wing

    Energy Technology Data Exchange (ETDEWEB)

    McCord, Samuel A [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Waste Management and Pollution Prevention

    2015-04-01

    Following a building-wide waste assessment in September, 2014, and subsequent presentation to Sandia leadership regarding the goal of Zero Waste by 2025, the occupants of the IPOC Second Floor, West Wing contacted the Materials Sustainability and Pollution Prevention (MSP2) team to guide them to Zero Waste in advance of the rest of the site. The occupants are from Center 3600, Public Relations and Communications , and Center 800, Independent Audit, Ethics and Business Conduct . To accomplish this, MSP2 conducted a new limited waste assessment from March 2-6, 2015 to compare the second floor, west wing to the building as a whole. The assessment also serves as a baseline with which to mark improvements in diversion in approximately 6 months.

  2. Effects of triplet Higgs bosons in long baseline neutrino experiments

    Science.gov (United States)

    Huitu, K.; Kärkkäinen, T. J.; Maalampi, J.; Vihonen, S.

    2018-05-01

    The triplet scalars (Δ =Δ++,Δ+,Δ0) utilized in the so-called type-II seesaw model to explain the lightness of neutrinos, would generate nonstandard interactions (NSI) for a neutrino propagating in matter. We investigate the prospects to probe these interactions in long baseline neutrino oscillation experiments. We analyze the upper bounds that the proposed DUNE experiment might set on the nonstandard parameters and numerically derive upper bounds, as a function of the lightest neutrino mass, on the ratio the mass MΔ of the triplet scalars, and the strength |λϕ| of the coupling ϕ ϕ Δ of the triplet Δ and conventional Higgs doublet ϕ . We also discuss the possible misinterpretation of these effects as effects arising from a nonunitarity of the neutrino mixing matrix and compare the results with the bounds that arise from the charged lepton flavor violating processes.

  3. The NuMAX Long Baseline Neutrino Factory Concept

    Energy Technology Data Exchange (ETDEWEB)

    Delahaye, J-P. [SLAC; Ankenbrandt, C. [MUONS Inc., Batavia; Bogacz, A. [Jefferson Lab; Huber, P. [Virginia Tech.; Kirk, H. [Brookhaven; Neuffer, D. [Fermilab; Palmer, M. A. [Fermilab; Ryne, R. [LBL, Berkeley; Snopok, P. [IIT, Chicago

    2018-03-19

    A Neutrino Factory where neutrinos of all species are produced in equal quantities by muon decay is described as a facility at the intensity frontier for exquisite precision providing ideal conditions for ultimate neutrino studies and the ideal complement to Long Baseline Facilities like LBNF at Fermilab. It is foreseen to be built in stages with progressively increasing complexity and performance, taking advantage of existing or proposed facilities at an existing laboratory like Fermilab. A tentative layout based on a recirculating linac providing opportunities for considerable saving is discussed as well as its possible evolution toward a muon collider if and when requested by Physics. Tentative parameters of the various stages are presented as well as the necessary R&D to address the technological issues and demonstrate their feasibility.

  4. Probing Neutrino Properties with Long-Baseline Neutrino Beams

    International Nuclear Information System (INIS)

    Marino, Alysia

    2015-01-01

    This final report on an Early Career Award grant began in April 15, 2010 and concluded on April 14, 2015. Alysia Marino's research is focussed on making precise measurements of neutrino properties using intense accelerator-generated neutrino beams. As a part of this grant, she is collaborating on the Tokai-to-Kamioka (T2K) long-baseline neutrino experiment, currently taking data in Japan, and on the Deep Underground Neutrino Experiment (DUNE) design effort for a future Long-Baseline Neutrino Facility (LBNF) in the US. She is also a member of the NA61/SHINE particle production experiment at CERN, but as that effort is supported by other funds, it will not be discussed further here. T2K was designed to search for the disappearance of muon neutrinos (?_?) and the appearance of electron neutrinos (?_e), using a beam of muon neutrino beam that travels 295 km across Japan towards the Super-Kamiokande detector. In 2011 T2K first reported indications of ?_e appearance, a previously unobserved mode of neutrino oscillations. In the past year, T2K has published a combined analysis of ?_? disappearance and ?_e appearance, and began collecting taking data with a beam of anti-neutrinos, instead of neutrinos, to search for hints of violation of the CP symmetry of the universe. The proposed DUNE experiment has similar physics goals to T2K, but will be much more sensitive due to its more massive detectors and new higher-intensity neutrino beam. This effort will be very high-priority particle physics project in the US over the next decade.

  5. Automated baseline change detection - Phases 1 and 2. Final report

    International Nuclear Information System (INIS)

    Byler, E.

    1997-01-01

    The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrel and on feature recognition in images. The ABCD image processing software was installed on a robotic vehicle developed under a related DOE/FETC contract DE-AC21-92MC29112 Intelligent Mobile Sensor System (IMSS) and integrated with the electronics and software. This vehicle was designed especially to navigate in DOE Waste Storage Facilities. Initial system testing was performed at Fernald in June 1996. After some further development and more extensive integration the prototype integrated system was installed and tested at the Radioactive Waste Management Facility (RWMC) at INEEL beginning in April 1997 through the present (November 1997). The integrated system, composed of ABCD imaging software and IMSS mobility base, is called MISS EVE (Mobile Intelligent Sensor System--Environmental Validation Expert). Evaluation of the integrated system in RWMC Building 628, containing approximately 10,000 drums, demonstrated an easy to use system with the ability to properly navigate through the facility, image all the defined drums, and process the results into a report delivered to the operator on a GUI interface and on hard copy. Further work is needed to make the brassboard system more operationally robust

  6. Circular polarization control for the LCLS baseline in the soft X-ray regime

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2010-12-15

    The LCLS baseline includes a planar undulator system, which produces intense linearly polarized light in the wavelength range 0.15-1.5 nm. In the soft X-ray wavelength region polarization control from linear to circular is highly desirable for studying ultrafast magnetic phenomena and material science issues. Several schemes using helical undulators have been discussed in the context of the LCLS. One consists in replacing three of the last planar undulator segments by helical (APPLE III) ones. A second proposal, the 2nd harmonic helical afterburner, is based on the use of short, crossed undulators tuned to the second harmonic. This last scheme is expected to be the better one. Its advantages are a high (over 90%) and stable degree of circular polarization and a low cost. Its disadvantage is a small output power (1% of the power at the fundamental harmonic) and a narrow wavelength range. We propose a novel method to generate 10 GW level power at the fundamental harmonic with 99% degree of circular polarization from the LCLS baseline. Its merits are low cost, simplicity and easy implementation. In the option presented here, the microbunching of the planar undulator is used too. After the baseline undulator, the electron beam is sent through a 40 m long straight section, and subsequently passes through a short helical (APPLE II) radiator. In this case the microbunch structure is easily preserved, and intense coherent radiation is emitted in the helical radiator. The background radiation from the baseline undulator can be easily suppressed by letting radiation and electron beamthrough horizontal and vertical slits upstream the helical radiator, where the radiation spot size is about ten times larger than the electron bunch transverse size. Using thin Beryllium foils for the slits the divergence of the electron beam halo will increase by Coulomb scattering, but the beam will propagate through the setup without electron losses. The applicability of our method is not

  7. Association between baseline impedance values and response proton pump inhibitors in patients with heartburn.

    Science.gov (United States)

    de Bortoli, Nicola; Martinucci, Irene; Savarino, Edoardo; Tutuian, Radu; Frazzoni, Marzio; Piaggi, Paolo; Bertani, Lorenzo; Furnari, Manuele; Franchi, Riccardo; Russo, Salvatore; Bellini, Massimo; Savarino, Vincenzo; Marchi, Santino

    2015-06-01

    Esophageal impedance measurements have been proposed to indicate the status of the esophageal mucosa, and might be used to study the roles of the impaired mucosal integrity and increased acid sensitivity in patients with heartburn. We compared baseline impedance levels among patients with heartburn who did and did not respond to proton pump inhibitor (PPI) therapy, along with the pathophysiological characteristics of functional heartburn (FH). In a case-control study, we collected data from January to December 2013 on patients with heartburn and normal findings from endoscopy who were not receiving PPI therapy and underwent impedance pH testing at hospitals in Italy. Patients with negative test results were placed on an 8-week course of PPI therapy (84 patients received esomeprazole and 36 patients received pantoprazole). Patients with more than 50% symptom improvement were classified as FH/PPI responders and patients with less than 50% symptom improvement were classified as FH/PPI nonresponders. Patients with hypersensitive esophagus and healthy volunteers served as controls. In all patients and controls, we measured acid exposure time, number of reflux events, baseline impedance, and swallow-induced peristaltic wave indices. FH/PPI responders had higher acid exposure times, numbers of reflux events, and acid refluxes compared with FH/PPI nonresponders (P < .05). Patients with hypersensitive esophagus had mean acid exposure times and numbers of reflux events similar to those of FH/PPI responders. Baseline impedance levels were lower in FH/PPI responders and patients with hypersensitive esophagus, compared with FH/PPI nonresponders and healthy volunteers (P < .001). Swallow-induced peristaltic wave indices were similar between FH/PPI responders and patients with hypersensitive esophagus. Patients with FH who respond to PPI therapy have impedance pH features similar to those of patients with hypersensitive esophagus. Baseline impedance measurements might allow for

  8. Baseline Physiologic and Psychosocial Characteristics of Transgender Youth Seeking Care for Gender Dysphoria.

    Science.gov (United States)

    Olson, Johanna; Schrager, Sheree M; Belzer, Marvin; Simons, Lisa K; Clark, Leslie F

    2015-10-01

    The purpose of this study was to describe baseline characteristics of participants in a prospective observational study of transgender youth (aged 12-24 years) seeking care for gender dysphoria at a large, urban transgender youth clinic. Eligible participants presented consecutively for care at between February 2011 and June 2013 and completed a computer-assisted survey at their initial study visit. Physiologic data were abstracted from medical charts. Data were analyzed by descriptive statistics, with limited comparisons between transmasculine and transfeminine participants. A total of 101 youth were evaluated for physiologic parameters, 96 completed surveys assessing psychosocial parameters. About half (50.5%) of the youth were assigned a male sex at birth. Baseline physiologic values were within normal ranges for assigned sex at birth. Youth recognized gender incongruence at a mean age of 8.3 years (standard deviation = 4.5), yet disclosed to their family much later (mean = 17.1; standard deviation = 4.2). Gender dysphoria was high among all participants. Thirty-five percent of the participants reported depression symptoms in the clinical range. More than half of the youth reported having thought about suicide at least once in their lifetime, and nearly a third had made at least one attempt. Baseline physiologic parameters were within normal ranges for assigned sex at birth. Transgender youth are aware of the incongruence between their internal gender identity and their assigned sex at early ages. Prevalence of depression and suicidality demonstrates that youth may benefit from timely and appropriate intervention. Evaluation of these youth over time will help determine the impact of medical intervention and mental health therapy. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  9. Esophageal baseline impedance levels in patients with pathophysiological characteristics of functional heartburn.

    Science.gov (United States)

    Martinucci, I; de Bortoli, N; Savarino, E; Piaggi, P; Bellini, M; Antonelli, A; Savarino, V; Frazzoni, M; Marchi, S

    2014-04-01

    Recently, it has been suggested that low esophageal basal impedance may reflect impaired mucosal integrity and increased acid sensitivity. We aimed to compare baseline impedance levels in patients with heartburn and pathophysiological characteristics related to functional heartburn (FH) divided into two groups on the basis of symptom relief after proton pump inhibitors (PPIs). Patients with heartburn and negative endoscopy were treated with esomeprazole or pantoprazole 40 mg daily for 8 weeks. According to MII-pH (off therapy) analysis, patients with normal acid exposure time (AET), normal reflux number, and lack of association between symptoms and refluxes were selected; of whom 30 patients with a symptom relief higher than 50% after PPIs composed Group A, and 30 patients, matched for sex and age, without symptom relief composed Group B. A group of 20 healthy volunteers (HVs) was enrolled. For each patient and HV, we evaluated the baseline impedance levels at channel 3, during the overnight rest, at three different times. Group A (vs Group B) showed an increase in the following parameters: mean AET (1.4 ± 0.8% vs 0.5 ± 0.6%), mean reflux number (30.4 ± 8.7 vs 24 ± 6.9), proximal reflux number (11.1 ± 5.2 vs 8.2 ± 3.6), acid reflux number (17.9 ± 6.1 vs 10.7 ± 6.9). Baseline impedance levels were lower in Group A than in Group B and in HVs (p heartburn and normal AET could achieve a better understanding of pathophysiology in reflux disease patients, and could improve the distinction between FH and hypersensitive esophagus. © 2014 John Wiley & Sons Ltd.

  10. Rapidly shifting baselines in Yangtze fishing communities and local memory of extinct species.

    Science.gov (United States)

    Turvey, Samuel T; Barrett, Leigh A; Yujiang, Hao; Lei, Zhang; Xinqiao, Zhang; Xianyan, Wang; Yadong, Huang; Kaiya, Zhou; Hart, Tom; Ding, Wang

    2010-06-01

    Local ecological knowledge can provide a unique source of data for conservation, especially in efforts to investigate the status of rare or possibly extinct species, but it is unlikely to remain constant over time. Loss of perspective about past ecological conditions caused by lack of communication between generations may create "shifting baseline syndrome," in which younger generations are less aware of local species diversity or abundance in the recent past. This phenomenon has been widely discussed, but has rarely been examined quantitatively. We present new evidence of shifting baselines in local perception of regional species declines and on the duration of "community memory" of extinct species on the basis of extensive interviews with fishers in communities across the middle-lower Yangtze basin. Many Yangtze species have experienced major declines in recent decades, and the Yangtze River dolphin or baiji (Lipotes vexillifer) and Yangtze paddlefish (Psephurus gladius) may have become extinct during the 21(st) century. Although informants across all age classes were strongly aware of the Yangtze ecosystem's escalating resource depletion and environmental degradation, older informants were more likely to recognize declines in two commercially important fish species, Reeves' shad (Tenualosa reevesii) and Yangtze pufferfish (Takifugu fasciatus), and to have encountered baiji and paddlefish in the past. Age was also a strong predictor of whether informants had even heard of baiji or paddlefish, with younger informants being substantially less likely to recognize either species. A marked decrease in local knowledge about the Yangtze freshwater megafauna matched the time of major population declines of these species from the 1970s onwards, and paddlefish were already unknown to over 70% of all informants below the age of 40 and to those who first started fishing after 1995. This rapid rate of cultural baseline shift suggests that once even megafaunal species cease to

  11. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation

    DEFF Research Database (Denmark)

    Bogh, Morten K B; Schmedes, Anne; Philipsen, Peter A

    2010-01-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total...... cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used...... to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol...

  12. Reinforced Carbon Carbon (RCC) oxidation resistant material samples - Baseline coated, and baseline coated with tetraethyl orthosilicate (TEOS) impregnation

    Science.gov (United States)

    Gantz, E. E.

    1977-01-01

    Reinforced carbon-carbon material specimens were machined from 19 and 33 ply flat panels which were fabricated and processed in accordance with the specifications and procedures accepted for the fabrication and processing of the leading edge structural subsystem (LESS) elements for the space shuttle orbiter. The specimens were then baseline coated and tetraethyl orthosilicate impregnated, as applicable, in accordance with the procedures and requirements of the appropriate LESS production specifications. Three heater bars were ATJ graphite silicon carbide coated with the Vought 'pack cementation' coating process, and three were stackpole grade 2020 graphite silicon carbide coated with the chemical vapor deposition process utilized by Vought in coating the LESS shell development program entry heater elements. Nondestructive test results are reported.

  13. Logistic regression function for detection of suspicious performance during baseline evaluations using concussion vital signs.

    Science.gov (United States)

    Hill, Benjamin David; Womble, Melissa N; Rohling, Martin L

    2015-01-01

    This study utilized logistic regression to determine whether performance patterns on Concussion Vital Signs (CVS) could differentiate known groups with either genuine or feigned performance. For the embedded measure development group (n = 174), clinical patients and undergraduate students categorized as feigning obtained significantly lower scores on the overall test battery mean for the CVS, Shipley-2 composite score, and California Verbal Learning Test-Second Edition subtests than did genuinely performing individuals. The final full model of 3 predictor variables (Verbal Memory immediate hits, Verbal Memory immediate correct passes, and Stroop Test complex reaction time correct) was significant and correctly classified individuals in their known group 83% of the time (sensitivity = .65; specificity = .97) in a mixed sample of young-adult clinical cases and simulators. The CVS logistic regression function was applied to a separate undergraduate college group (n = 378) that was asked to perform genuinely and identified 5% as having possibly feigned performance indicating a low false-positive rate. The failure rate was 11% and 16% at baseline cognitive testing in samples of high school and college athletes, respectively. These findings have particular relevance given the increasing use of computerized test batteries for baseline cognitive testing and return-to-play decisions after concussion.

  14. The LIFE Cognition Study: design and baseline characteristics

    Directory of Open Access Journals (Sweden)

    Sink KM

    2014-08-01

    adults at increased risk for incident mobility disability. One LIFE Study objective is to evaluate the effects of a structured physical activity program on changes in cognitive function and incident all-cause mild cognitive impairment or dementia. Here, we present the design and baseline cognitive data. At baseline, participants completed the modified Mini Mental Status Examination, Hopkins Verbal Learning Test, Digit Symbol Coding, Modified Rey–Osterrieth Complex Figure, and a computerized battery, selected to be sensitive to changes in speed of processing and executive functioning. During follow up, participants completed the same battery, along with the Category Fluency for Animals, Boston Naming, and Trail Making tests. The description of the mild cognitive impairment/dementia adjudication process is presented here. Participants with worse baseline Short Physical Performance Battery scores (prespecified at ≤7 had significantly lower median cognitive test scores compared with those having scores of 8 or 9 with modified Mini Mental Status Examination score of 91 versus (vs 93, Hopkins Verbal Learning Test delayed recall score of 7.4 vs 7.9, and Digit Symbol Coding score of 45 vs 48, respectively (all P<0.001. The LIFE Study will contribute important information on the effects of a structured physical activity program on cognitive outcomes in sedentary older adults at particular risk for mobility impairment. In addition to its importance in the area of prevention of cognitive decline, the LIFE Study will also likely serve as a model for exercise and other behavioral intervention trials in older adults. Keywords: exercise, physical activity, older adults, dementia

  15. Idaho National Laboratory’s Greenhouse Gas FY08 Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2010-09-01

    A greenhouse gas (GHG) inventory is a systematic attempt to account for the production and release of certain gasses generated by an institution from various emission sources. The gasses of interest are those which have become identified by climate science as related to anthropogenic global climate change. This document presents an inventory of GHGs generated during fiscal year (FY) 2008 by Idaho National Laboratory (INL), a Department of Energy (DOE)-sponsored entity, located in southeastern Idaho. Concern about the environmental impact of GHGs has grown in recent years. This, together with a desire to decrease harmful environmental impacts, would be enough to encourage the calculation of a baseline estimate of total GHGs generated at the INL. Additionally, the INL has a desire to see how its emissions compare with similar institutions, including other DOE-sponsored national laboratories. Executive Order 13514 requires that federally-sponsored agencies and institutions document reductions in GHG emissions in the future, and such documentation will require knowledge of a baseline against which reductions can be measured. INL’s FY08 GHG inventory was calculated according to methodologies identified in Federal recommendations and an as-yet-unpublished Technical and Support Document (TSD) using operational control boundary. It measures emissions generated in three Scopes: (1) INL emissions produced directly by stationary or mobile combustion and by fugitive emissions, (2) the share of emissions generated by entities from which INL purchased electrical power, and (3) indirect or shared emissions generated by outsourced activities that benefit INL (occur outside INL’s organizational boundaries but are a consequence of INL’s activities). This inventory found that INL generated a total of 114,256 MT of CO2-equivalent emissions during fiscal year 2008 (FY08). The following conclusions were made from looking at the results of the individual contributors to INL

  16. Idaho National Laboratory’s Greenhouse Gas FY08 Baseline

    Energy Technology Data Exchange (ETDEWEB)

    Jennifer D. Morton

    2011-06-01

    A greenhouse gas (GHG) inventory is a systematic attempt to account for the production and release of certain gasses generated by an institution from various emission sources. The gasses of interest are those which have become identified by climate science as related to anthropogenic global climate change. This document presents an inventory of GHGs generated during fiscal year (FY) 2008 by Idaho National Laboratory (INL), a Department of Energy (DOE)-sponsored entity, located in southeastern Idaho. Concern about the environmental impact of GHGs has grown in recent years. This, together with a desire to decrease harmful environmental impacts, would be enough to encourage the calculation of a baseline estimate of total GHGs generated at INL. Additionally, INL has a desire to see how its emissions compare with similar institutions, including other DOE national laboratories. Executive Order 13514 requires that federal agencies and institutions document reductions in GHG emissions in the future, and such documentation will require knowledge of a baseline against which reductions can be measured. INL's FY08 GHG inventory was calculated according to methodologies identified in federal GHG guidance documents using operational control boundaries. It measures emissions generated in three Scopes: (1) INL emissions produced directly by stationary or mobile combustion and by fugitive emissions, (2) the share of emissions generated by entities from which INL purchased electrical power, and (3) indirect or shared emissions generated by outsourced activities that benefit INL (occur outside INL's organizational boundaries but are a consequence of INL's activities). This inventory found that INL generated a total of 113,049 MT of CO2-equivalent emissions during FY08. The following conclusions were made from looking at the results of the individual contributors to INL's baseline GHG inventory: (1) Electricity (including the associated transmission and

  17. Conservation of forest birds: evidence of a shifting baseline in community structure.

    Directory of Open Access Journals (Sweden)

    Chadwick D Rittenhouse

    2010-08-01

    Full Text Available Quantifying changes in forest bird diversity is an essential task for developing effective conservation actions. When subtle changes in diversity accumulate over time, annual comparisons may offer an incomplete perspective of changes in diversity. In this case, progressive change, the comparison of changes in diversity from a baseline condition, may offer greater insight because changes in diversity are assessed over longer periods of times. Our objectives were to determine how forest bird diversity has changed over time and whether those changes were associated with forest disturbance.We used North American Breeding Bird Survey data, a time series of Landsat images classified with respect to land cover change, and mixed-effects models to associate changes in forest bird community structure with forest disturbance, latitude, and longitude in the conterminous United States for the years 1985 to 2006. We document a significant divergence from the baseline structure for all birds of similar migratory habit and nest location, and all forest birds as a group from 1985 to 2006. Unexpectedly, decreases in progressive similarity resulted from small changes in richness (<1 species per route for the 22-year study period and modest losses in abundance (-28.7 - -10.2 individuals per route that varied by migratory habit and nest location. Forest disturbance increased progressive similarity for Neotropical migrants, permanent residents, ground nesting, and cavity nesting species. We also documented highest progressive similarity in the eastern United States.Contemporary forest bird community structure is changing rapidly over a relatively short period of time (e.g., approximately 22 years. Forest disturbance and forest regeneration are primary factors associated with contemporary forest bird community structure, longitude and latitude are secondary factors, and forest loss is a tertiary factor. Importantly, these findings suggest some regions of the United

  18. Conservation of forest birds: evidence of a shifting baseline in community structure.

    Science.gov (United States)

    Rittenhouse, Chadwick D; Pidgeon, Anna M; Albright, Thomas P; Culbert, Patrick D; Clayton, Murray K; Flather, Curtis H; Huang, Chengquan; Masek, Jeffrey G; Stewart, Susan I; Radeloff, Volker C

    2010-08-02

    Quantifying changes in forest bird diversity is an essential task for developing effective conservation actions. When subtle changes in diversity accumulate over time, annual comparisons may offer an incomplete perspective of changes in diversity. In this case, progressive change, the comparison of changes in diversity from a baseline condition, may offer greater insight because changes in diversity are assessed over longer periods of times. Our objectives were to determine how forest bird diversity has changed over time and whether those changes were associated with forest disturbance. We used North American Breeding Bird Survey data, a time series of Landsat images classified with respect to land cover change, and mixed-effects models to associate changes in forest bird community structure with forest disturbance, latitude, and longitude in the conterminous United States for the years 1985 to 2006. We document a significant divergence from the baseline structure for all birds of similar migratory habit and nest location, and all forest birds as a group from 1985 to 2006. Unexpectedly, decreases in progressive similarity resulted from small changes in richness (<1 species per route for the 22-year study period) and modest losses in abundance (-28.7 - -10.2 individuals per route) that varied by migratory habit and nest location. Forest disturbance increased progressive similarity for Neotropical migrants, permanent residents, ground nesting, and cavity nesting species. We also documented highest progressive similarity in the eastern United States. Contemporary forest bird community structure is changing rapidly over a relatively short period of time (e.g., approximately 22 years). Forest disturbance and forest regeneration are primary factors associated with contemporary forest bird community structure, longitude and latitude are secondary factors, and forest loss is a tertiary factor. Importantly, these findings suggest some regions of the United States may

  19. Baseline Geochemical Data for Medical Researchers in Kentucky

    Science.gov (United States)

    Anderson, W.

    2017-12-01

    According to the Centers for Disease Control, Kentucky has the highest cancer incidence and death rates in the country. New efforts by geochemists and medical researchers are examining ways to diagnose the origin and sources of carcinogenesis. In an effort to determine if naturally occurring geochemical or mineral elements contributes to the cancer causation, the Kentucky Geological Survey has established a Minerals and Geochemical Database that is available to medical researchers for examination of baseline geochemistry and determine if naturally occurring mineral or chemical elements contribute to the high rate of cancers in the state. Cancer causation is complex, so if natural sources can be accounted for, then researchers can focus on the true causation. Naturally occurring minerals, metals and elements occur in many parts of the state, and their presence is valuable for evaluating causation. For example, some data in the database contain maps showing (a) statewide elemental geochemistry, (b) areas of black shale oxidation occurrence, which releases metals in soil and surface waters, (c) some clay deposits in the state that can contain high content of rare earth elements, and (d) site-specific uranium occurrences. Knowing the locations of major ore deposits in the state can also provide information related to mineral and chemical anomalies, such as for base metals and mercury. Radionuclide data in soil and water analyses are limited, so future research may involve obtaining more analyses to determine radon potential. This database also contains information on faulting and geology in the state. Although the metals content of trees may not seem relevant, the ash and humus content of degraded trees affects soil, stream sediment and water geochemistry. Many rural homes heat with wood, releasing metals into the surrounding biosphere. Stressed vegetation techniques can be used to explore for ore deposits and look for high metal contents in soils and rocks. These

  20. Despite worse baseline status depressed patients achieved outcomes similar to those in nondepressed patients after surgery for cervical deformity.

    Science.gov (United States)

    Poorman, Gregory W; Passias, Peter G; Horn, Samantha R; Frangella, Nicholas J; Daniels, Alan H; Hamilton, D Kojo; Kim, Hanjo; Sciubba, Daniel; Diebo, Bassel G; Bortz, Cole A; Segreto, Frank A; Kelly, Michael P; Smith, Justin S; Neuman, Brian J; Shaffrey, Christopher I; LaFage, Virginie; LaFage, Renaud; Ames, Christopher P; Hart, Robert; Mundis, Gregory M; Eastlack, Robert

    2017-12-01

    OBJECTIVE Depression and anxiety have been demonstrated to have negative impacts on outcomes after spine surgery. In patients with cervical deformity (CD), the psychological and physiological burdens of the disease may overlap without clear boundaries. While surgery has a proven record of bringing about significant pain relief and decreased disability, the impact of depression and anxiety on recovery from cervical deformity corrective surgery has not been previously reported on in the literature. The purpose of the present study was to determine the effect of depression and anxiety on patients' recovery from and improvement after CD surgery. METHODS The authors conducted a retrospective review of a prospective, multicenter CD database. Patients with a history of clinical depression, in addition to those with current self-reported anxiety or depression, were defined as depressed (D group). The D group was compared with nondepressed patients (ND group) with a similar baseline deformity determined by propensity score matching of the cervical sagittal vertical axis (cSVA). Baseline demographic, comorbidity, clinical, and radiographic data were compared among patients using t-tests. Improvement of symptoms was recorded at 3 months, 6 months, and 1 year postoperatively. All health-related quality of life (HRQOL) scores collected at these follow-up time points were compared using t-tests. RESULTS Sixty-six patients were matched for baseline radiographic parameters: 33 with a history of depression and/or current depression, and 33 without. Depressed patients had similar age, sex, race, and radiographic alignment: cSVA, T-1 slope minus C2-7 lordosis, SVA, and T-1 pelvic angle (p > 0.05). Compared with nondepressed individuals, depressed patients had a higher incidence of osteoporosis (21.2% vs 3.2%, p = 0.028), rheumatoid arthritis (18.2% vs 3.2%, p = 0.012), and connective tissue disorders (18.2% vs 3.2%, p = 0.012). At baseline, the D group had greater neck pain (7.9 of

  1. A sampling strategy to establish existing plant configuration baselines

    International Nuclear Information System (INIS)

    Buchanan, L.P.

    1995-01-01

    The Department of Energy's Gaseous Diffusion Plants (DOEGDP) are undergoing a Safety Analysis Update Program. As part of this program, critical existing structures are being reevaluated for Natural Phenomena Hazards (NPH) based on the recommendations of UCRL-15910. The Department of Energy has specified that current plant configurations be used in the performance of these reevaluations. This paper presents the process and results of a walkdown program implemented at DOEGDP to establish the current configuration baseline for these existing critical structures for use in subsequent NPH evaluations. These structures are classified as moderate hazard facilities and were constructed in the early 1950's. The process involved a statistical sampling strategy to determine the validity of critical design information as represented on the original design drawings such as member sizes, orientation, connection details and anchorage. A floor load inventory of the dead load of the equipment, both permanently attached and spare, was also performed as well as a walkthrough inspection of the overall structure to identify any other significant anomalies

  2. B Plant aggregate area management study technical baseline report

    International Nuclear Information System (INIS)

    DeFord, D.H.; Carpenter, R.W.

    1995-05-01

    The B aggregate area is made up of 13 operable units; 200-BP 1 through 200-BP 1 1, 200-IU-6, and 200-SS-1 that consist of liquid and solid waste disposal sites in the vicinity of, and related to, B Plant operations. This report describes B Plant and its waste sites, including cribs, french drains, septic tanks and drain fields, trenches and ditches, ponds, catch tanks, settling tanks, diversion boxes, underground tank farms designed for high-level liquid wastes, and the lines and encasements that connect them. Each waste site in the aggregate area is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. This document provides a technical baseline of the aggregate area and results from an environmental investigation. This document is based upon review and evaluation of numerous Hanford Site current and historical reports, drawings and photographs, supplemented with site inspections and employee interviews. No intrusive field investigations or sampling were conducted

  3. Energy conservation on Nova Scotia farms: Baseline energy data

    International Nuclear Information System (INIS)

    Bailey, J.A.; Gordon, R.; Burton, D.; Yiridoe, E.K.

    2008-01-01

    Direct energy use is a small but essential component of the farm greenhouse gas (GHG) budget. Improvements in energy efficiency and renewable energy can help reduce farm operating costs, improve air quality and reduce GHG emission levels. Energy conservation is especially important in Nova Scotia (NS), Canada, where fossil fuels, particularly coal, remain the primary source of electrical generation. Responses from mail surveys were used to establish baseline data on a cross-section of NS farms with respect to direct energy costs and usage to demonstrate differences in farm type and size. A 32% (N=224) response rate was achieved. Based on this survey, the average energy bill for a NS farm in 2004 was $11,228, with most (61.7%) of their energy cost attributable to the purchase of petroleum products. Almost all farmers (96.4%) indicated that their energy cost was a primary concern. Farmers identified the operation of vehicles and mobile equipment, as well as lighting and heating as having the greatest energy requirements in their operations. Energy usage varied with farm type and size. NS farms consumed 1.2 petajoules of energy equivalent to 127 kilotonnes of CO 2 with 52.7% of emissions from electricity use in 2004

  4. Future Long-Baseline Neutrino Facilities and Detectors

    Directory of Open Access Journals (Sweden)

    Milind Diwan

    2013-01-01

    Full Text Available We review the ongoing effort in the US, Japan, and Europe of the scientific community to study the location and the detector performance of the next-generation long-baseline neutrino facility. For many decades, research on the properties of neutrinos and the use of neutrinos to study the fundamental building blocks of matter has unveiled new, unexpected laws of nature. Results of neutrino experiments have triggered a tremendous amount of development in theory: theories beyond the standard model or at least extensions of it and development of the standard solar model and modeling of supernova explosions as well as the development of theories to explain the matter-antimatter asymmetry in the universe. Neutrino physics is one of the most dynamic and exciting fields of research in fundamental particle physics and astrophysics. The next-generation neutrino detector will address two aspects: fundamental properties of the neutrino like mass hierarchy, mixing angles, and the CP phase, and low-energy neutrino astronomy with solar, atmospheric, and supernova neutrinos. Such a new detector naturally allows for major improvements in the search for nucleon decay. A next-generation neutrino observatory needs a huge, megaton scale detector which in turn has to be installed in a new, international underground laboratory, capable of hosting such a huge detector.

  5. Transuranic waste baseline inventory report. Revision No. 3

    International Nuclear Information System (INIS)

    1996-06-01

    The Transuranic Waste Baseline Inventory Report (TWBIR) establishes a methodology for grouping wastes of similar physical and chemical properties from across the U.S. Department of Energy (DOE) transuranic (TRU) waste system into a series of open-quotes waste profilesclose quotes that can be used as the basis for waste form discussions with regulatory agencies. The purpose of Revisions 0 and 1 of this report was to provide data to be included in the Sandia National Laboratories/New Mexico (SNL/NM) performance assessment (PA) processes for the Waste Isolation Pilot Plant (WIPP). Revision 2 of the document expanded the original purpose and was also intended to support the WIPP Land Withdrawal Act (LWA) requirement for providing the total DOE TRU waste inventory. The document included a chapter and an appendix that discussed the total DOE TRU waste inventory, including nondefense, commercial, polychlorinated biphenyls (PCB)-contaminated, and buried (predominately pre-1970) TRU wastes that are not planned to be disposed of at WIPP

  6. GPS survey in long baseline neutrino-oscillation measurement

    CERN Document Server

    Noumi, H; Inagaki, T; Hasegawa, T; Katoh, Y; Kohama, M; Kurodai, M; Kusano, E; Maruyama, T; Minakawa, M; Nakamura, K; Nishikawa, K; Sakuda, M; Suzuki, Y; Takasaki, M; Tanaka, K H; Yamanoi, Y; 10.1109/TNS.2004.836042

    2004-01-01

    We made a series of surveys to obtain neutrino beam line direction toward SuperKamiokande (SK) at a distance of 250 km for the long- baseline neutrino oscillation experiment at KEK. We found that the beam line is directed to SK within 0.03 mr and 0.09 mr (in sigma) in the horizontal and vertical directions, respectively. During beam operation, we monitored the muon distribution from secondary pions produced at the target and collected by a magnetic horn system. We found that the horn system functions like a lens of a point-to- parallel optics with magnification of approximately -100 and the focal length of 2.3 m. Namely, a small displacement of the primary beam position at the target is magnified about a factor -100 at the muon centroid, while the centroid position is almost stable against a change of the incident angle of the primary beam. Therefore, the muon centroid can be a useful monitor of the neutrino beam direction. We could determine the muon centroid within 6 mm and 12 mm in horizontal and vertical ...

  7. Predicted radiation environment of the Saturn baseline diode

    International Nuclear Information System (INIS)

    Halbleib, J.A.; Lee, J.R.

    1987-09-01

    Coupled electron/photon Monte Carlo radiation transport was used to predict the radiation environment of the Saturn accelerator for the baseline diode design. The x-ray output has been calculated, as well as energy deposition in CaF 2 thermoluminescent dosimetry and silicon. It is found that the design criteria for the radiation environment will be met and that approximately 10 kJ of x rays will be available for simulation experiments, if the diode provides a nominal beam of 2.0-MeV electrons for 20 ns with a peak current of 12.5 MA. The penalty in dose and x-ray output for operating below the nominal energy in order to obtain a softer spectrum is quantified. The penalty for using excessive electron equilibration in the standard packaging of the thermoluminescent dosimeters is shown to be negligible. An intrinsic lack of electron equilibration for silicon elements of components and subsystems is verified for Saturn environments, demonstrating the ambiguity of design criteria based on silicon deposition. Validation of an efficient next-event-estimator method for predicting energy deposition in equilibrated detectors/dosimetry is confirmed. Finally, direct-electron depositions in excess of 1 kJ/g are shown to be easily achievable. 34 refs., 30 figs

  8. Neutrino oscillations on the way to long-baseline experiments

    CERN Document Server

    Ryabov, V A

    2003-01-01

    The motivations and physical objectives of experiments in the search for nu /sub mu / to nu /sub e/, nu /sub tau / oscillations in long- baseline accelerator neutrino beams are reviewed. Neutrino beams, detectors, and methods for detecting oscillations (detection of the disappearance of nu /sub mu /, and the appearance of nu /sub e/ and nu /sub tau /) in the current K2K (KEK to Super Kamiokande) experiment and in the MINOS (FNAL to Soudan) and OPERA (CERN to Gran Sasso) near-future experiments are discussed. Possibilities of measuring the oscillation parameters in these experiments are considered in connection with new data obtained in CHOOZ and Palo Verde reactor experiments, the solar neutrino deficit and nu /sub mu // nu /sub e/ anomaly of atmospheric neutrinos, which are observed in large-scale underground detectors, and the excess of nu /sub e/ events in the LSND experiment. Neutrino-oscillation scenarios used in models with three and four (including sterile) types of neutrino, as well as the possibility...

  9. Education Organization Baseline Control Protection and Trusted Level Security

    Directory of Open Access Journals (Sweden)

    Wasim A. Al-Hamdani

    2007-12-01

    Full Text Available Many education organizations have adopted for security the enterprise best practices for implementation on their campuses, while others focus on ISO Standard (or/and the National Institution of Standards and Technology.All these adoptions are dependent on IT personal and their experiences or knowledge of the standard. On top of this is the size of the education organizations. The larger the population in an education organization, the more the problem of information and security become very clear. Thus, they have been obliged to comply with information security issues and adopt the national or international standard. The case is quite different when the population size of the education organization is smaller. In such education organizations, they use social security numbers as student ID, and issue administrative rights to faculty and lab managers – or they are not aware of the Family Educational Rights and Privacy Act (FERPA – and release some personal information.The problem of education organization security is widely open and depends on the IT staff and their information security knowledge in addition to the education culture (education, scholarships and services has very special characteristics other than an enterprise or comparative organizationThis paper is part of a research to develop an “Education Organization Baseline Control Protection and Trusted Level Security.” The research has three parts: Adopting (standards, Testing and Modifying (if needed.

  10. Updated baseline for a staged Compact Linear Collider

    CERN Document Server

    Boland, M J; Giansiracusa, P J; Lucas, T G; Rassool, R P; Balazs, C; Charles, T K; Afanaciev, K; Emeliantchik, I; Ignatenko, A; Makarenko, V; Shumeiko, N; Patapenka, A; Zhuk, I; Abusleme Hoffman, A C; Diaz Gutierrez, M A; Gonzalez, M Vogel; Chi, Y; He, X; Pei, G; Pei, S; Shu, G; Wang, X; Zhang, J; Zhao, F; Zhou, Z; Chen, H; Gao, Y; Huang, W; Kuang, Y P; Li, B; Li, Y; Shao, J; Shi, J; Tang, C; Wu, X; Ma, L; Han, Y; Fang, W; Gu, Q; Huang, D; Huang, X; Tan, J; Wang, Z; Zhao, Z; Laštovička, T; Uggerhoj, U; Wistisen, T N; Aabloo, A; Eimre, K; Kuppart, K; Vigonski, S; Zadin, V; Aicheler, M; Baibuz, E; Brücken, E; Djurabekova, F; Eerola, P; Garcia, F; Haeggström, E; Huitu, K; Jansson, V; Karimaki, V; Kassamakov, I; Kyritsakis, A; Lehti, S; Meriläinen, A; Montonen, R; Niinikoski, T; Nordlund, K; Österberg, K; Parekh, M; Törnqvist, N A; Väinölä, J; Veske, M; Farabolini, W; Mollard, A; Napoly, O; Peauger, F; Plouin, J; Bambade, P; Chaikovska, I; Chehab, R; Davier, M; Kaabi, W; Kou, E; LeDiberder, F; Pöschl, R; Zerwas, D; Aimard, B; Balik, G; Baud, J-P; Blaising, J-J; Brunetti, L; Chefdeville, M; Drancourt, C; Geoffroy, N; Jacquemier, J; Jeremie, A; Karyotakis, Y; Nappa, J M; Vilalte, S; Vouters, G; Bernard, A; Peric, I; Gabriel, M; Simon, F; Szalay, M; van der Kolk, N; Alexopoulos, T; Gazis, E N; Gazis, N; Ikarios, E; Kostopoulos, V; Kourkoulis, S; Gupta, P D; Shrivastava, P; Arfaei, H; Dayyani, M K; Ghasem, H; Hajari, S S; Shaker, H; Ashkenazy, Y; Abramowicz, H; Benhammou, Y; Borysov, O; Kananov, S; Levy, A; Levy, I; Rosenblat, O; D'Auria, G; Di Mitri, S; Abe, T; Aryshev, A; Higo, T; Makida, Y; Matsumoto, S; Shidara, T; Takatomi, T; Takubo, Y; Tauchi, T; Toge, N; Ueno, K; Urakawa, J; Yamamoto, A; Yamanaka, M; Raboanary, R; Hart, R; van der Graaf, H; Eigen, G; Zalieckas, J; Adli, E; Lillestøl, R; Malina, L; Pfingstner, J; Sjobak, K N; Ahmed, W; Asghar, M I; Hoorani, H; Bugiel, S; Dasgupta, R; Firlej, M; Fiutowski, T A; Idzik, M; Kopec, M; Kuczynska, M; Moron, J; Swientek, K P; Daniluk, W; Krupa, B; Kucharczyk, M; Lesiak, T; Moszczynski, A; Pawlik, B; Sopicki, P; Wojtoń, T; Zawiejski, L; Kalinowski, J; Krawczyk, M; Żarnecki, A F; Firu, E; Ghenescu, V; Neagu, A T; Preda, T; Zgura, I-S; Aloev, A; Azaryan, N; Budagov, J; Chizhov, M; Filippova, M; Glagolev, V; Gongadze, A; Grigoryan, S; Gudkov, D; Karjavine, V; Lyablin, M; Olyunin, A; Samochkine, A; Sapronov, A; Shirkov, G; Soldatov, V; Solodko, A; Solodko, E; Trubnikov, G; Tyapkin, I; Uzhinsky, V; Vorozhtov, A; Levichev, E; Mezentsev, N; Piminov, P; Shatilov, D; Vobly, P; Zolotarev, K; Bozovic-Jelisavcic, I; Kacarevic, G; Lukic, S; Milutinovic-Dumbelovic, G; Pandurovic, M; Iriso, U; Perez, F; Pont, M; Trenado, J; Aguilar-Benitez, M; Calero, J; Garcia-Tabares, L; Gavela, D; Gutierrez, J L; Lopez, D; Toral, F; Moya, D; Ruiz-Jimeno, A; Vila, I; Argyropoulos, T; Blanch Gutierrez, C; Boronat, M; Esperante, D; Faus-Golfe, A; Fuster, J; Fuster Martinez, N; Galindo Muñoz, N; García, I; Giner Navarro, J; Ros, E; Vos, M; Brenner, R; Ekelöf, T; Jacewicz, M; Ögren, J; Olvegård, M; Ruber, R; Ziemann, V; Aguglia, D; Alipour Tehrani, N; Aloev, A; Andersson, A; Andrianala, F; Antoniou, F; Artoos, K; Atieh, S; Ballabriga Sune, R; Barnes, M J; Barranco Garcia, J; Bartosik, H; Belver-Aguilar, C; Benot Morell, A; Bett, D R; Bettoni, S; Blanchot, G; Blanco Garcia, O; Bonnin, X A; Brunner, O; Burkhardt, H; Calatroni, S; Campbell, M; Catalan Lasheras, N; Cerqueira Bastos, M; Cherif, A; Chevallay, E; Constance, B; Corsini, R; Cure, B; Curt, S; Dalena, B; Dannheim, D; De Michele, G; De Oliveira, L; Deelen, N; Delahaye, J P; Dobers, T; Doebert, S; Draper, M; Duarte Ramos, F; Dubrovskiy, A; Elsener, K; Esberg, J; Esposito, M; Fedosseev, V; Ferracin, P; Fiergolski, A; Foraz, K; Fowler, A; Friebel, F; Fuchs, J-F; Fuentes Rojas, C A; Gaddi, A; Garcia Fajardo, L; Garcia Morales, H; Garion, C; Gatignon, L; Gayde, J-C; Gerwig, H; Goldblatt, A N; Grefe, C; Grudiev, A; Guillot-Vignot, F G; Gutt-Mostowy, M L; Hauschild, M; Hessler, C; Holma, J K; Holzer, E; Hourican, M; Hynds, D; Inntjore Levinsen, Y; Jeanneret, B; Jensen, E; Jonker, M; Kastriotou, M; Kemppinen, J M K; Kieffer, R B; Klempt, W; Kononenko, O; Korsback, A; Koukovini Platia, E; Kovermann, J W; Kozsar, C-I; Kremastiotis, I; Kulis, S; Latina, A; Leaux, F; Lebrun, P; Lefevre, T; Linssen, L; Llopart Cudie, X; Maier, A A; Mainaud Durand, H; Manosperti, E; Marelli, C; Marin Lacoma, E; Martin, R; Mazzoni, S; Mcmonagle, G; Mete, O; Mether, L M; Modena, M; Münker, R M; Muranaka, T; Nebot Del Busto, E; Nikiforou, N; Nisbet, D; Nonglaton, J-M; Nuiry, F X; Nürnberg, A; Olvegard, M; Osborne, J; Papadopoulou, S; Papaphilippou, Y; Passarelli, A; Patecki, M; Pazdera, L; Pellegrini, D; Pepitone, K; Perez, F; Perez Codina, E; Perez Fontenla, A; Persson, T H B; Petrič, M; Pitters, F; Pittet, S; Plassard, F; Rajamak, R; Redford, S; Renier, Y; Rey, S F; Riddone, G; Rinolfi, L; Rodriguez Castro, E; Roloff, P; Rossi, C; Rude, V; Rumolo, G; Sailer, A; Santin, E; Schlatter, D; Schmickler, H; Schulte, D; Shipman, N; Sicking, E; Simoniello, R; Skowronski, P K; Sobrino Mompean, P; Soby, L; Sosin, M P; Sroka, S; Stapnes, S; Sterbini, G; Ström, R; Syratchev, I; Tecker, F; Thonet, P A; Timeo, L; Timko, H; Tomas Garcia, R; Valerio, P; Vamvakas, A L; Vivoli, A; Weber, M A; Wegner, R; Wendt, M; Woolley, B; Wuensch, W; Uythoven, J; Zha, H; Zisopoulos, P; Benoit, M; Vicente Barreto Pinto, M; Bopp, M; Braun, H H; Csatari Divall, M; Dehler, M; Garvey, T; Raguin, J Y; Rivkin, L; Zennaro, R; Aksoy, A; Nergiz, Z; Pilicer, E; Tapan, I; Yavas, O; Baturin, V; Kholodov, R; Lebedynskyi, S; Miroshnichenko, V; Mordyk, S; Profatilova, I; Storizhko, V; Watson, N; Winter, A; Goldstein, J; Green, S; Marshall, J S; Thomson, M A; Xu, B; Gillespie, W A; Pan, R; Tyrk, M A; Protopopescu, D; Robson, A; Apsimon, R; Bailey, I; Burt, G; Constable, D; Dexter, A; Karimian, S; Lingwood, C; Buckland, M D; Casse, G; Vossebeld, J; Bosco, A; Karataev, P; Kruchinin, K; Lekomtsev, K; Nevay, L; Snuverink, J; Yamakawa, E; Boisvert, V; Boogert, S; Boorman, G; Gibson, S; Lyapin, A; Shields, W; Teixeira-Dias, P; West, S; Jones, R; Joshi, N; Bodenstein, R; Burrows, P N; Christian, G B; Gamba, D; Perry, C; Roberts, J; Clarke, J A; Collomb, N A; Jamison, S P; Shepherd, B J A; Walsh, D; Demarteau, M; Repond, J; Weerts, H; Xia, L; Wells, J D; Adolphsen, C; Barklow, T; Breidenbach, M; Graf, N; Hewett, J; Markiewicz, T; McCormick, D; Moffeit, K; Nosochkov, Y; Oriunno, M; Phinney, N; Rizzo, T; Tantawi, S; Wang, F; Wang, J; White, G; Woodley, M

    2016-01-01

    The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of...

  11. Baseline for beached marine debris on Sand Island, Midway Atoll

    Science.gov (United States)

    Ribic, Christine; Seba B. Sheavly,; John Klavitter,

    2012-01-01

    Baseline measurements were made of the amount and weight of beached marine debris on Sand Island, Midway Atoll, June 2008–July 2010. On 23 surveys, 32,696 total debris objects (identifiable items and pieces) were collected; total weight was 740.4 kg. Seventy-two percent of the total was pieces; 91% of the pieces were made of plastic materials. Pieces were composed primarily of polyethylene and polypropylene. Identifiable items were 28% of the total; 88% of the identifiable items were in the fishing/aquaculture/shipping-related and beverage/household products-related categories. Identifiable items were lowest during April–August, while pieces were at their lowest during June–August. Sites facing the North Pacific Gyre received the most debris and proportionately more pieces. More debris tended to be found on Sand Island when the Subtropical Convergence Zone was closer to the Atoll. This information can be used for potential mitigation and to understand the impacts of large-scale events such as the 2011 Japanese tsunami.

  12. Baseline brain energy supports the state of consciousness.

    Science.gov (United States)

    Shulman, Robert G; Hyder, Fahmeed; Rothman, Douglas L

    2009-07-07

    An individual, human or animal, is defined to be in a conscious state empirically by the behavioral ability to respond meaningfully to stimuli, whereas the loss of consciousness is defined by unresponsiveness. PET measurements of glucose or oxygen consumption show a widespread approximately 45% reduction in cerebral energy consumption with anesthesia-induced loss of consciousness. Because baseline brain energy consumption has been shown by (13)C magnetic resonance spectroscopy to be almost exclusively dedicated to neuronal signaling, we propose that the high level of brain energy is a necessary property of the conscious state. Two additional neuronal properties of the conscious state change with anesthesia. The delocalized fMRI activity patterns in rat brain during sensory stimulation at a higher energy state (close to the awake) collapse to a contralateral somatosensory response at lower energy state (deep anesthesia). Firing rates of an ensemble of neurons in the rat somatosensory cortex shift from the gamma-band range (20-40 Hz) at higher energy state to energy state. With the conscious state defined by the individual's behavior and maintained by high cerebral energy, measurable properties of that state are the widespread fMRI patterns and high frequency neuronal activity, both of which support the extensive interregional communication characteristic of consciousness. This usage of high brain energies when the person is in the "state" of consciousness differs from most studies, which attend the smaller energy increments observed during the stimulations that form the "contents" of that state.

  13. Future Long-Baseline Neutrino Facilities and Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Diwan, Milind [Brookhaven; Edgecock, Rob [Huddersfield U.; Hasegawa, Takuya [KEK, Tsukuba; Patzak, Thomas [APC, Paris; Shiozawa, Masato [Kamioka Observ.; Strait, Jim [Fermilab

    2013-01-01

    We review the ongoing effort in the US, Japan, and Europe of the scientific community to study the location and the detector performance of the next-generation long-baseline neutrino facility. For many decades, research on the properties of neutrinos and the use of neutrinos to study the fundamental building blocks of matter has unveiled new, unexpected laws of nature. Results of neutrino experiments have triggered a tremendous amount of development in theory: theories beyond the standard model or at least extensions of it and development of the standard solar model and modeling of supernova explosions as well as the development of theories to explain the matter-antimatter asymmetry in the universe. Neutrino physics is one of the most dynamic and exciting fields of research in fundamental particle physics and astrophysics. The next-generation neutrino detector will address two aspects: fundamental properties of the neutrino like mass hierarchy, mixing angles, and the CP phase, and low-energy neutrino astronomy with solar, atmospheric, and supernova neutrinos. Such a new detector naturally allows for major improvements in the search for nucleon decay. A next-generation neutrino observatory needs a huge, megaton scale detector which in turn has to be installed in a new, international underground laboratory, capable of hosting such a huge detector.

  14. Neutrino Oscillation Parameter Sensitivity in Future Long-Baseline Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bass, Matthew [Colorado State Univ., Fort Collins, CO (United States)

    2014-01-01

    The study of neutrino interactions and propagation has produced evidence for physics beyond the standard model and promises to continue to shed light on rare phenomena. Since the discovery of neutrino oscillations in the late 1990s there have been rapid advances in establishing the three flavor paradigm of neutrino oscillations. The 2012 discovery of a large value for the last unmeasured missing angle has opened the way for future experiments to search for charge-parity symmetry violation in the lepton sector. This thesis presents an analysis of the future sensitivity to neutrino oscillations in the three flavor paradigm for the T2K, NO A, LBNE, and T2HK experiments. The theory of the three flavor paradigm is explained and the methods to use these theoretical predictions to design long baseline neutrino experiments are described. The sensitivity to the oscillation parameters for each experiment is presented with a particular focus on the search for CP violation and the measurement of the neutrino mass hierarchy. The variations of these sensitivities with statistical considerations and experimental design optimizations taken into account are explored. The effects of systematic uncertainties in the neutrino flux, interaction, and detection predictions are also considered by incorporating more advanced simulations inputs from the LBNE experiment.

  15. Baseline Testing of the Club Car Carryall With Asymmetric Ultracapacitors

    Science.gov (United States)

    Eichenberg, Dennis J.

    2003-01-01

    The NASA John H. Glenn Research Center initiated baseline testing of the Club Car Carryall with asymmetric ultracapacitors as a way to reduce pollution in industrial settings, reduce fossil fuel consumption, and reduce operating costs for transportation systems. The Club Car Carryall provides an inexpensive approach to advance the state of the art in electric vehicle technology in a practical application. The project transfers space technology to terrestrial use via non-traditional partners, and provides power system data valuable for future space applications. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB). The Carryall is a state of the art, ground up, electric utility vehicle. A unique aspect of the project was the use of a state of the art, long life ultracapacitor energy storage system. Innovative features, such as regenerative braking through ultracapacitor energy storage, are planned. Regenerative braking recovers much of the kinetic energy of the vehicle during deceleration. The Carryall was tested with the standard lead acid battery energy storage system, as well as with an asymmetric ultracapacitor energy storage system. The report concludes that the Carryall provides excellent performance, and that the implementation of asymmetric ultracapacitors in the power system can provide significant performance improvements.

  16. Baseline Testing of The EV Global E-Bike

    Science.gov (United States)

    Eichenberg, Dennis J.; Kolacz, John S.; Tavernelli, Paul F.

    2001-01-01

    The NASA John H. Glenn Research Center initiated baseline testing of the EV Global E-Bike as a way to reduce pollution in urban areas, reduce fossil fuel consumption and reduce Operating costs for transportation systems. The work was done Linder the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB). The E-Bike is a state of the art, ground up, hybrid electric bicycle. Unique features of the vehicle's power system include the use of an efficient, 400 W. electric hub motor and a 7-speed derailleur system that permits operation as fully electric, fully pedal, or a combination of the two. Other innovative features, such as regenerative braking through ultracapacitor energy storage are planned. Regenerative braking recovers much of the kinetic energy of the vehicle during deceleration. The E-Bike is an inexpensive approach to advance the state of the art in hybrid technology in a practical application. The project transfers space technology to terrestrial use via nontraditional partners, and provides power system data valuable for future space applications. A description of the E-bike, the results of performance testing, and future vehicle development plans is the subject of this report. The report concludes that the E-Bike provides excellent performance, and that the implementation of ultracapacitors in the power system can provide significant performance improvements.

  17. Baseline concentrations of nuclear fuel waste nuclides in the environment

    International Nuclear Information System (INIS)

    Amiro, B.D.

    1992-04-01

    Protection of the environment is a key issue in the disposal of long-lived radioactive wastes. To assess the implications of undergound disposal, transport models are commonly used to predict radionuclide concentrations in soil and water. However, an appropriate framework needs to be established to ensure that the predicted concentrations do not impose unacceptable environmental impacts. Here, we suggest baseline environmental concentrations of the most important radionuclides in nuclear fuel waste. We summarize background concentrations of the nuclides in soil and surface water, and suggest Environmental Increments (EI) that could be added to soil and water without causing detectable effects. The EI values are based mostly on natural variability, but some alternative methods are used for radionuclides that are very rare in nature. The background concentrations and EI values are most useful as a screening tool to help identify potentially unacceptable concentrations arising from a disposal concept. When available, we also report data on concentrations that have been measured in the environment without causing an observable effect. This review focuses especially on concentrations applicable to the Canadian Precambrian Shield, as part of the Canadian concept of nuclear fuel waste disposal in a deep, stable geological formation

  18. Ultra-high pressure water jet: Baseline report

    International Nuclear Information System (INIS)

    1997-01-01

    The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is recommended because of the outdoor environment where the testing demonstration took place. In addition, other areas of concern found were arm-hand vibration, ergonomics, heat stress, tripping hazards, electrical hazards, lockout/tagout, fall hazards, slipping hazards, hazards associated with the high pressure water, and hazards associated with air pressure systems

  19. Pentek concrete scabbling system: Baseline report; Greenbook (chapter)

    International Nuclear Information System (INIS)

    1997-01-01

    The Pentek scabbling technology was tested at Florida International University (FIU) and is being evaluated as a baseline technology. This report evaluates it for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek concrete scabbling system consisted of the MOOSE, SQUIRREL-I, and SQUIRREL-III scabblers. The scabblers are designed to scarify concrete floors and slabs using cross-section, tungsten carbide tipped bits. The bits are designed to remove concrete in 318 inch increments. The bits are either 9-tooth or demolition type. The scabblers are used with a vacuum system designed to collect and filter the concrete dust and contamination that is removed from the surface. The safety and health evaluation conducted during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure was minimal, but noise exposure was significant. Further testing for each of these exposures is recommended. Because of the outdoor environment where the testing demonstration took place, results may be inaccurate. It is feasible that the dust and noise levels will be higher in an enclosed operating environment. Other areas of concern were arm-hand vibration, whole-body vibration, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout

  20. Pentek metal coating removal system: Baseline report; Greenbook (chapter)

    International Nuclear Information System (INIS)

    1997-01-01

    The Pentek coating removal technology was tested and is being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The Pentek coating removal system consisted of the ROTO-PEEN Scaler, CORNER-CUTTER reg-sign, and VAC-PAC reg-sign. They are designed to remove coatings from steel, concrete, brick, and wood. The Scaler uses 3M Roto Peen tungsten carbide cutters while the CORNER-CUTTER reg-sign uses solid needles for descaling activities. These hand tools are used with the VAC-PAC reg-sign vacuum system to capture dust and debris as removal of the coating takes place. The safety and health evaluation during the testing demonstration focused on two main areas of exposure: dust and noise. Dust exposure minimal, but noise exposure was significant. Further testing for each exposure is recommended because of the environment where the testing demonstration took place. It is feasible that the dust and noise levels will be higher in an enclosed operating environment of different construction. In addition, other areas of concern found were arm-hand vibration, whole-body, ergonomics, heat stress, tripping hazards, electrical hazards, machine guarding, and lockout/tagout

  1. Digital curation of research data experiences of a baseline study in Germany

    CERN Document Server

    Strathmann, Stefan; Oßwald, Achim; Ludwig, Jens

    2013-01-01

    The relevance of research data today and for the future is well documented and discussed, in Germany as well as internationally. Ensuring that research data are accessible, sharable, and re-usable over time is increasingly becoming an essential task for researchers and research infrastructure institutions. Some reasons for this development include the following: - research data are documented and could therefore be validated - research data could be the basis for new research questions - research data could be re-analyzed by using innovative digital methods - research data could be used by other disciplines Therefore, it is essential that research data are curated, which means they are kept accessible and interpretable over time. In Germany, a baseline study was undertaken analyzing the situation in eleven research disciplines in 2012. The results were then published in a German-language edition. To address an international audience, the German-language edition of the study has been translated and abridged. T...

  2. Quantifying the extent of North American mammal extinction relative to the pre-anthropogenic baseline.

    Science.gov (United States)

    Carrasco, Marc A; Barnosky, Anthony D; Graham, Russell W

    2009-12-16

    Earth has experienced five major extinction events in the past 450 million years. Many scientists suggest we are now witnessing a sixth, driven by human impacts. However, it has been difficult to quantify the real extent of the current extinction episode, either for a given taxonomic group at the continental scale or for the worldwide biota, largely because comparisons of pre-anthropogenic and anthropogenic biodiversity baselines have been unavailable. Here, we compute those baselines for mammals of temperate North America, using a sampling-standardized rich fossil record to reconstruct species-area relationships for a series of time slices ranging from 30 million to 500 years ago. We show that shortly after humans first arrived in North America, mammalian diversity dropped to become at least 15%-42% too low compared to the "normal" diversity baseline that had existed for millions of years. While the Holocene reduction in North American mammal diversity has long been recognized qualitatively, our results provide a quantitative measure that clarifies how significant the diversity reduction actually was. If mass extinctions are defined as loss of at least 75% of species on a global scale, our data suggest that North American mammals had already progressed one-fifth to more than halfway (depending on biogeographic province) towards that benchmark, even before industrialized society began to affect them. Data currently are not available to make similar quantitative estimates for other continents, but qualitative declines in Holocene mammal diversity are also widely recognized in South America, Eurasia, and Australia. Extending our methodology to mammals in these areas, as well as to other taxa where possible, would provide a reasonable way to assess the magnitude of global extinction, the biodiversity impact of extinctions of currently threatened species, and the efficacy of conservation efforts into the future.

  3. Baseline Caesium-137 and Plutonium-239+240 inventory assessment for Central Europe

    Science.gov (United States)

    Meusburger, Katrin; Borelli, Pasquale; Evrard, Olivier; Ketterer, Michael; Mabit, Lionel; van Oost, Kristof; Alewell, Christine; Panagos, Panos

    2017-04-01

    Artificial fallout radionuclides (FRNs) such as Caesium-137 and Plutonium-239+240 released as products of the thermonuclear weapons testing that took place from the mid-1950s to the early 1980s and from nuclear power plant accidents (e.g. Chernobyl) are useful tools to quantify soil redistribution. In combination with geostatistics, FRNs may have the potential to bridge the gap between small scale process oriented studies and modelling that simplifies processes and effects over large spatial scales. An essential requirement for the application of FRNs as soil erosion tracers is the establishment of the baseline fallout at undisturbed sites before its comparison to those inventories found at sites undergoing erosion/accumulation. For this purpose, undisturbed topsoil (0-20cm) samples collected in 2009 within the framework of the Land Use/Cover Area frame Survey (LUCAS) have been measured by gamma-spectrometry and ICP-MS to determine 137Cs (n=145) and 239+240Pu (n=108) activities. To restrict the analysis to undisturbed reference sites a geospatial database query selecting only sites having a slope angle <2 degree, outside riparian zones (to avoid depositional sites) and under permanent grassland cover (according to CORINE Land Cover and Landsat) was applied. This study reports preliminary results on the feasibility of establishing a 137Cs and 239+240Pu baseline inventory map for Central Europe. The 137Cs/239+240Pu activity ratios will further allow assessing the rate and the spatial variability of 137Cs Chernobyl fallout. The establishment of such baseline inventory map will provide a unique opportunity to assess soil redistribution for a comparable time-frame (1953-2009) following a harmonised methodological protocol across national boundaries.

  4. Quantifying the extent of North American mammal extinction relative to the pre-anthropogenic baseline.

    Directory of Open Access Journals (Sweden)

    Marc A Carrasco

    2009-12-01

    Full Text Available Earth has experienced five major extinction events in the past 450 million years. Many scientists suggest we are now witnessing a sixth, driven by human impacts. However, it has been difficult to quantify the real extent of the current extinction episode, either for a given taxonomic group at the continental scale or for the worldwide biota, largely because comparisons of pre-anthropogenic and anthropogenic biodiversity baselines have been unavailable. Here, we compute those baselines for mammals of temperate North America, using a sampling-standardized rich fossil record to reconstruct species-area relationships for a series of time slices ranging from 30 million to 500 years ago. We show that shortly after humans first arrived in North America, mammalian diversity dropped to become at least 15%-42% too low compared to the "normal" diversity baseline that had existed for millions of years. While the Holocene reduction in North American mammal diversity has long been recognized qualitatively, our results provide a quantitative measure that clarifies how significant the diversity reduction actually was. If mass extinctions are defined as loss of at least 75% of species on a global scale, our data suggest that North American mammals had already progressed one-fifth to more than halfway (depending on biogeographic province towards that benchmark, even before industrialized society began to affect them. Data currently are not available to make similar quantitative estimates for other continents, but qualitative declines in Holocene mammal diversity are also widely recognized in South America, Eurasia, and Australia. Extending our methodology to mammals in these areas, as well as to other taxa where possible, would provide a reasonable way to assess the magnitude of global extinction, the biodiversity impact of extinctions of currently threatened species, and the efficacy of conservation efforts into the future.

  5. Cost-effective way to enhance the capabilities of the LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2010-08-15

    This paper discusses the potential for enhancing the LCLS hard X-ray FEL capabilities. In the hard X-ray regime, a high longitudinal coherence will be the key to such performance upgrade. The method considered here to obtain high longitudinal coherence is based on a novel single-bunch self-seeding scheme exploiting a single crystal monochromator, which is extremely compact and can be straightforwardly installed in the LCLS baseline undulator. We present simulation results dealing with the LCLS hard X-ray FEL, and show that this method can produce fully-coherent X-ray pulses at 100 GW power level. With the radiation beam monochromatized down to the Fourier transform limit, a variety of very different techniques leading to further improvements of the LCLS performance become feasible. In particular, we describe an efficient way for obtaining full polarization control at the LCLS hard X-ray FEL. We also propose to exploit crystals in the Bragg reflection geometry as movable deflectors for the LCLS X-ray transport systems. The hard X-ray beam can be deflected of an angle of order of a radian without perturbations. The monochromatization of the output radiation constitutes the key for reaching such result. Finally, we describe a newoptical pump - hard X-ray probe technique which will allow time-resolved studies at the LCLS baseline on the femtosecond time scale. The principle of operation of the proposed scheme is essentially based on the use of the time jitter between pump and probe pulses. This eliminates the need for timing XFELs to high-power conventional lasers with femtosecond accuracy. (orig.)

  6. Cost-effective way to enhance the capabilities of the LCLS baseline

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-08-01

    This paper discusses the potential for enhancing the LCLS hard X-ray FEL capabilities. In the hard X-ray regime, a high longitudinal coherence will be the key to such performance upgrade. The method considered here to obtain high longitudinal coherence is based on a novel single-bunch self-seeding scheme exploiting a single crystal monochromator, which is extremely compact and can be straightforwardly installed in the LCLS baseline undulator. We present simulation results dealing with the LCLS hard X-ray FEL, and show that this method can produce fully-coherent X-ray pulses at 100 GW power level. With the radiation beam monochromatized down to the Fourier transform limit, a variety of very different techniques leading to further improvements of the LCLS performance become feasible. In particular, we describe an efficient way for obtaining full polarization control at the LCLS hard X-ray FEL. We also propose to exploit crystals in the Bragg reflection geometry as movable deflectors for the LCLS X-ray transport systems. The hard X-ray beam can be deflected of an angle of order of a radian without perturbations. The monochromatization of the output radiation constitutes the key for reaching such result. Finally, we describe a newoptical pump - hard X-ray probe technique which will allow time-resolved studies at the LCLS baseline on the femtosecond time scale. The principle of operation of the proposed scheme is essentially based on the use of the time jitter between pump and probe pulses. This eliminates the need for timing XFELs to high-power conventional lasers with femtosecond accuracy. (orig.)

  7. Correlation between hypersensitivity induced by esophageal acid infusion and the baseline impedance level in patients with suspected gastroesophageal reflux.

    Science.gov (United States)

    Seo, A Young; Shin, Cheol Min; Kim, Nayoung; Yoon, Hyuk; Park, Young Soo; Lee, Dong Ho

    2015-07-01

    To evaluate the relevance between the pH parameters and baseline impedance level or esophageal hypomotility in patients with suspected gastroesophageal reflux. The recordings of 51 patients with heartburn, acid regurgitation, globus or noncardiac chest pain were analyzed. Evaluation included a 24-h multichannel intraluminal impedance-pH test while on off-proton pump inhibitor therapy over 1 week, high-resolution manometry and Bernstein test. Mean baseline impedance level at the most distal portion of the impedance channel was assessed manually. Esophageal hypomotility was evaluated using transitional zone defect (TZD) and distal break (DB) length measurement. In the study subjects (n = 51), 6 had a DeMeester score of more than 14.7 and 14 had a positive symptom index. The Bernstein test was positive in ten patients. The baseline impedance level was inversely correlated with the acid exposure time % (r = -0.660, P reflux and weakly acid reflux time % measured by impedance monitoring showed a weak correlation with TZD + DB length (r = 0.327 and 0.324, P = 0.019 and 0.020, respectively). Although a positive Bernstein test has no relevance for the acid exposure time or acid-related symptoms as represented by the DeMeester score or symptom index, the baseline impedance level was significantly lower in patients with a positive Bernstein test than in those with a negative one (2,628.4 ± 862.7 vs. 1,752.2 ± 611.1 Ω, P = 0.004). A lower baseline impedance level is closely related to increased esophageal acid exposure. Hypersensitivity induced by esophageal acid infusion might be attributed to acid-induced mucosal changes of the esophagus.

  8. A Danish survey of spinal cord stimulation baseline data: First results from a national neuromodulation database

    DEFF Research Database (Denmark)

    Meier, Kaare; Scherer, Christian; Rosenlund, Christina

    A Danish survey of spinal cord stimulation baseline data: First results from a national neuromodulation database......A Danish survey of spinal cord stimulation baseline data: First results from a national neuromodulation database...

  9. Astrometry of 25 Southern Hemisphere Radio Sources From A VLBI Short-Baseline Survey

    National Research Council Canada - National Science Library

    Fey, Alan

    2004-01-01

    .... These positions are derived from Mark III Very Long Baseline Interferometry observations made between 2003 September and 2004 May on the intra-Australia baseline connecting Hobart, Tasmania and Parkes, New South Wales...

  10. Markers and residual time to AIDS

    NARCIS (Netherlands)

    Geskus, R. B.

    2002-01-01

    The value of immunological and virological markers as predictors of progression to AIDS, or death by AIDS, is a topic of much current interest. Mostly, the influence of markers is investigated in a time-dependent or a baseline proportional hazard model, relating time-varying or baseline marker

  11. India's baseline plan for nuclear energy self-sufficiency

    International Nuclear Information System (INIS)

    Bucher, R.G.

    2009-01-01

    India's nuclear energy strategy has traditionally strived for energy self-sufficiency, driven largely by necessity following trade restrictions imposed by the Nuclear Suppliers Group (NSG) following India's 'peaceful nuclear explosion' of 1974. On September 6, 2008, the NSG agreed to create an exception opening nuclear trade with India, which may create opportunities for India to modify its baseline strategy. The purpose of this document is to describe India's 'baseline plan,' which was developed under constrained trade conditions, as a basis for understanding changes in India's path as a result of the opening of nuclear commerce. Note that this treatise is based upon publicly available information. No attempt is made to judge whether India can meet specified goals either in scope or schedule. In fact, the reader is warned a priori that India's delivery of stated goals has often fallen short or taken a significantly longer period to accomplish. It has been evident since the early days of nuclear power that India's natural resources would determine the direction of its civil nuclear power program. It's modest uranium but vast thorium reserves dictated that the country's primary objective would be thorium utilization. Estimates of India's natural deposits vary appreciably, but its uranium reserves are known to be extremely limited, totaling approximately 80,000 tons, on the order of 1% of the world's deposits; and nominally one-third of this ore is of very low uranium concentration. However, India's roughly 300,000 tons of thorium reserves account for approximately 30% of the world's total. Confronted with this reality, the future of India's nuclear power industry is strongly dependent on the development of a thorium-based nuclear fuel cycle as the only way to insure a stable, sustainable, and autonomous program. The path to India's nuclear energy self-sufficiency was first outlined in a seminal paper by Drs. H. J. Bhabha and N. B. Prasad presented at the Second

  12. Office of Geologic Repositories program baseline procedures notebook (OGR/B-1)

    International Nuclear Information System (INIS)

    1986-06-01

    Baseline management is typically applied to aid in the internal control of a program by providing consistent programmatic direction, control, and surveillance to an evolving system development. This fundamental concept of internal program control involves the establishment of a baseline to serve as a point of departure for consistent technical program coordination and to control subsequent changes from that baseline. The existence of a program-authorized baseline ensures that all participants are working to the same ground rules. Baseline management also ensures that, once the baseline is defined, changes are assessed and approved by a process which ensures adequate consideration of overall program impact. Baseline management also includes the consideration of examptions from the baseline. The process of baseline management continues through all the phases of an evolving system development program. As the Program proceeds, there will be a progressive increase in the data contained in the baseline documentation. Baseline management has been selected as a management technique to aid in the internal control of the Office of Geologic Repositories (OGR) program. Specifically, an OGR Program Baseline, including technical and programmatic requirements, is used for program control of the four Mined Geologic Disposal System field projects, i.e., Basalt Waste Isolation Project, Nevada Nuclear Waste Storage Investigation, Salt Repository Project and Crystalline Repository Project. This OGR Program Baseline Procedures Notebook provides a description of the baseline mwanagement concept, establishes the OGR Program baseline itself, and provides procedures to be followed for controlling changes to that baseline. The notebook has a controlled distribution and will be updated as required

  13. Long-Term Stewardship Baseline Report and Transition Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Kristofferson, Keith

    2001-11-01

    Long-term stewardship consists of those actions necessary to maintain and demonstrate continued protection of human health and the environment after facility cleanup is complete. As the Department of Energy’s (DOE) lead laboratory for environmental management programs, the Idaho National Engineering and Environmental Laboratory (INEEL) administers DOE’s long-term stewardship science and technology efforts. The INEEL provides DOE with technical, and scientific expertise needed to oversee its long-term environmental management obligations complexwide. Long-term stewardship is administered and overseen by the Environmental Management Office of Science and Technology. The INEEL Long-Term Stewardship Program is currently developing the management structures and plans to complete INEEL-specific, long-term stewardship obligations. This guidance document (1) assists in ensuring that the program leads transition planning for the INEEL with respect to facility and site areas and (2) describes the classes and types of criteria and data required to initiate transition for areas and sites where the facility mission has ended and cleanup is complete. Additionally, this document summarizes current information on INEEL facilities, structures, and release sites likely to enter long-term stewardship at the completion of DOE’s cleanup mission. This document is not intended to function as a discrete checklist or local procedure to determine readiness to transition. It is an overarching document meant as guidance in implementing specific transition procedures. Several documents formed the foundation upon which this guidance was developed. Principal among these documents was the Long-Term Stewardship Draft Technical Baseline; A Report to Congress on Long-Term Stewardship, Volumes I and II; Infrastructure Long-Range Plan; Comprehensive Facility Land Use Plan; INEEL End-State Plan; and INEEL Institutional Plan.

  14. California Baseline Ozone Transport Study (CABOTS): Ozonesonde Measurements

    Science.gov (United States)

    Eiserloh, A. J., Jr.; Chiao, S.; Spitze, J.; Cauley, S.; Clark, J.; Roberts, M.

    2016-12-01

    Because the EPA recently lowered the ambient air quality standard for the 8-hr average of ozone (O3) to70 ppbv, California must continue to achieve significant reductions in ozone precursor emissions and prepare for new State Implementation Plans (SIP) to demonstrate how ground-level ambient ozone will be reduced below the new health-based standard. Prior studies suggest that background levels of ozone traveling across the Pacific Ocean can significantly influence surface ozone throughout California, particularly during the spring. Evidence has been presented indicating that background levels of ozone continue to increase in the western United States over the recent few decades, implying more ozone exceedances in the future. To better understand the contributions of the external natural and anthropogenic pollution sources as well as atmospheric processes for surface ozone concentrations in California during the spring and summer months, the California Baseline Ozone Transport Study (CABOTS) has been established. One major goal of CABOTS is to implement near daily ozonesonde measurements along the California Coast to quantify background ozone aloft before entering the State during high ozone season. CABOTS has been ongoing from May through August of 2016 launching ozonesondes from Bodega Bay and Half Moon Bay, California. The temporal progression of ozonesonde measurements and subsequent analysis of the data will be discussed with a focus on the contribution of background ozone to surface ozone sites inland as well as likely origins of layers aloft. Comparisons of current ozonesondes versus prior ozonesonde studies of California will also be performed. A few selected cases of high ozone layers moving onshore from different sources will be discussed as well.

  15. 40 CFR 80.290 - How does a refiner apply for a sulfur baseline?

    Science.gov (United States)

    2010-07-01

    ... baseline? 80.290 Section 80.290 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (abt) Program-General Information § 80.290 How does a refiner apply for a sulfur baseline? (a) The... accordance with § 80.217. (b) The sulfur baseline request must be sent to: U.S. EPA, Attn: Sulfur Program...

  16. 41 CFR 109-1.5202 - Establishment of a personal property holdings baseline.

    Science.gov (United States)

    2010-07-01

    ... personal property holdings baseline. 109-1.5202 Section 109-1.5202 Public Contracts and Property Management...-1.5202 Establishment of a personal property holdings baseline. (a) If the contractor is a new... baseline or may perform a complete physical inventory of all personal property. This physical inventory is...

  17. 40 CFR 80.245 - How does a small refiner apply for a sulfur baseline?

    Science.gov (United States)

    2010-07-01

    ... sulfur baseline? 80.245 Section 80.245 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Provisions § 80.245 How does a small refiner apply for a sulfur baseline? (a) Any refiner seeking small refiner status must apply for a refinery sulfur baseline by the deadline under § 80.235 for each of the...

  18. 40 CFR 80.910 - How does a refiner or importer apply for a toxics baseline?

    Science.gov (United States)

    2010-07-01

    ... for a toxics baseline? 80.910 Section 80.910 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Toxics Baseline Determination § 80.910 How does a refiner or importer apply for a toxics baseline? (a)(1) A refiner or importer...

  19. Baseline Projection Data Book: GRI baseline projection of U.S. Energy Supply and Demand to 2010. 1992 Edition. Volume 1 and Volume 2

    International Nuclear Information System (INIS)

    Holtberg, P.D.; Woods, T.J.; Lihn, M.L.; Koklauner, A.K.

    1992-01-01

    The 1992 Baseline Projection Data Book provides backup data in tabular form for the 1992 GRI Baseline Projection of U.S. Energy Supply and Demand to 2010. Summary tables and data for the residential, commercial, industrial, electric utility, and transportation sectors are presented in the volume

  20. Baseline Validation of Unstructured Grid Reynolds-Averaged Navier-Stokes Toward Flow Control

    Science.gov (United States)

    Joslin, Ronald D.; Viken, Sally A.

    2001-01-01

    experiments for the no-control case before proceeding to the time-dependent flow control case. This paper documents the baseline (no-control) case using an unswept airfoil configuration. The next section describes the configurations used for the computations and the experimentals. The computational approach is then described followed by results and concluding remarks.

  1. Association between baseline psychological attributes and mental health outcomes after soldiers returned from deployment.

    Science.gov (United States)

    Shen, Yu-Chu; Arkes, Jeremy; Lester, Paul B

    2017-10-05

    Psychological health is vital for effective employees, especially in stressful occupations like military and public safety sectors. Yet, until recently little empirical work has made the link between requisite psychological resources and important mental health outcomes across time in those sectors. In this study we explore the association between 14 baseline psychological health attributes (such as adaptability, coping ability, optimism) and mental health outcomes following exposure to combat deployment. Retrospective analysis of all U.S. Army soldiers who enlisted between 2009 and 2012 and took the Global Assessment Tools (GAT) before their first deployment (n = 63,186). We analyze whether a soldier screened positive for depression and posttraumatic stress disorder (PTSD) after returning from deployment using logistic regressions. Our key independent variables are 14 psychological attributes based on GAT, and we control for relevant demographic and service characteristics. In addition, we generate a composite risk score for each soldier based on the predicted probabilities from the above multivariate model using just baseline psychological attributes and demographic information. Comparing those who scored in the bottom 5 percentile of each attribute to those in the top 95 percentile, the odds ratio of post-deployment depression symptoms ranges from 1.21 (95% CI 1.06, 1.40) for organizational trust to 1.73 (CI 1.52, 1.97) for baseline depression. The odds ratio of positive screening of PTSD symptoms ranges from 1.22 for family support (CI 1.08, 1.38) to 1.51 for baseline depression (CI 1.32, 1.73). The risk profile analysis shows that 31% of those who screened positive for depression and 27% of those who screened positive for PTSD were concentrated among the top 5% high risk population. A set of validated, self-reported questions administered early in a soldier's career can predict future mental health problems, and can be used to improve workforce fit and

  2. Baseline values of micronuclei and comet assay in the lizard Tupinambis merianae (Teiidae, Squamata).

    Science.gov (United States)

    Schaumburg, Laura G; Poletta, Gisela L; Siroski, Pablo A; Mudry, Marta D

    2012-10-01

    The Micronucleus test (MN) and Comet assay (CA) are currently the most widely used methods that allow the characterization of DNA damage induced by physical and chemical agents in wild species. The continuous expansion of the cultivated areas in Argentina, since the introduction of transgenic crops, mainly soy, in association with the increased use of pesticides, transformed deeply the natural environments where the lizard Tupinambis merianae (tegu lizard) occurs. Despite the fact that reptiles have shown to be excellent bioindicators of environmental contaminants, there is no record of genotoxicity studies in T. merianae. The aim of the present study was to adjust the MN test and CA protocols to be applied in erythrocytes of T. merianae, and determine the baseline values of DNA damage in this species. We used 20 adult lizards (10 males: 10 females) from Estación Zoológica Experimental "Granja La Esmeralda" (Santa Fe, Argentina). Peripheral blood samples were collected from all animals and the MN test and CA applied according to the protocols established for other reptilian species. We test critical parameters of CA protocol (cell density, unwinding and electrophoresis times) using increasing concentrations of H2O2 (10, 25 and 50 μM) as a known genotoxic agent to induce DNA damage. Based on this, we determined the most suitable conditions for the CA in this species: a cell density of 4×10(3) erythrocytes per slide, 10 min of unwinding and 15 min of electrophoresis at 0.90 V/cm approximately. The baseline frequency of micronuclei (BFMN=MN/1000 erythrocytes counted) determined for this species was 0.95±0.27 and the basal damage index (BDI: calculated from 100 comet images classified in arbitrary units)=103.85±0.97. No differences were observed between sexes in the BFMN or BDI (p>0.05), and no relation was found between baseline values and length or weight of the analyzed animals (p>0.05). These results demonstrated the sensitivity of both biomarkers of

  3. COMPARISON OF THREE METHODS TO PROJECT FUTURE BASELINE CARBON EMISSIONS IN TEMPERATE RAINFOREST, CURINANCO, CHILE

    Energy Technology Data Exchange (ETDEWEB)

    Patrick Gonzalez; Antonio Lara; Jorge Gayoso; Eduardo Neira; Patricio Romero; Leonardo Sotomayor

    2005-07-14

    evaluate the three methods to project future baseline carbon emissions. Extrapolation from Landsat change detection uses the observed rate of change to estimate change in the near future. Geomod is a software program that models the geographic distribution of change using a defined rate of change. FRCA is an integrated spatial analysis of forest inventory, biodiversity, and remote sensing that produces estimates of forest biodiversity and forest carbon density, spatial data layers of future probabilities of reforestation and deforestation, and a projection of future baseline forest carbon sequestration and emissions for an ecologically-defined area of analysis. For the period 1999-2012, extrapolation from Landsat change detection estimated a loss of 5000 ha and 520,000 t carbon from closed natural forest; Geomod modeled a loss of 2500 ha and 250 000 t; FRCA projected a loss of 4700 {+-} 100 ha and 480,000 t (maximum 760,000 t, minimum 220,000 t). Concerning labor time, extrapolation for Landsat required 90 actual days or 120 days normalized to Bachelor degree level wages; Geomod required 240 actual days or 310 normalized days; FRCA required 110 actual days or 170 normalized days. Users experienced difficulties with an MS-DOS version of Geomod before turning to the Idrisi version. For organizations with limited time and financing, extrapolation from Landsat change provides a cost-effective method. Organizations with more time and financing could use FRCA, the only method where that calculates the deforestation rate as a dependent variable rather than assuming a deforestation rate as an independent variable. This research indicates that best practices for the projection of baseline carbon emissions include integration of forest inventory and remote sensing tasks from the beginning of the analysis, definition of an analysis area using ecological characteristics, use of standard and widely used geographic information systems (GIS) software applications, and the use of species

  4. Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

    International Nuclear Information System (INIS)

    Klepper, C.C.; Biewer, T.M.; Marcus, C.; Graves, V.B.; Andrew, P.; Hughes, S.; Gardner, W.L.

    2017-01-01

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for /textasciitilde 1 s response time from the sensor cluster [1].

  5. Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

    Science.gov (United States)

    Klepper, C. C.; Biewer, T. M.; Marcus, C.; Andrew, P.; Gardner, W. L.; Graves, V. B.; Hughes, S.

    2017-10-01

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \\textasciitilde 1 s response time from the sensor cluster [1].

  6. Baseline Characteristics of fall from Height Victims Presenting to Emergency Department; a Brief Report.

    Science.gov (United States)

    Hatamabadi, Hamidreza; Arhami Dolatabadi, Ali; Atighinasab, Batoul; Safari, Saeed

    2017-01-01

    Trauma due to accidents or fall from height is a major cause of disability and mortality. The present study was designed aiming to evaluate the baseline characteristics of fall from height victims presenting to emergency department (ED). This prospective cross-sectional study evaluates the baseline characteristics of fall from height cases presenting to EDs of three educational Hospitals, Tehran, Iran, during one year. Data were analyzed using SPSS 21 and presented using descriptive statistics. 460 patients with the mean age of 27.89 ± 20.95 years were evaluated (76.5% male). 191 (41.5%) falls occurred when working, 27 (5.9%) during play, and 242 (52.6%) in other times. Among construction workers, 166 (81.4%) had not used any safety equipment. Fracture and dislocation with 180 (39.1%) cases and soft tissue injury with 166 (36.1%) were the most common injuries inflicted. Mean height of falling was 3.41 ± 0.34 (range: 0.5 - 20) meters. Finally, 8 (1.7%) of the patients died (50% intentional) and 63% were discharged from ED. A significant correlation was detected between mortality and the falls being intentional (p construction workers, with less than high school diploma education level. Intentional fall and greater height of falling significantly correlated with mortality.

  7. A Baseline for the Multivariate Comparison of Resting-State Networks

    Science.gov (United States)

    Allen, Elena A.; Erhardt, Erik B.; Damaraju, Eswar; Gruner, William; Segall, Judith M.; Silva, Rogers F.; Havlicek, Martin; Rachakonda, Srinivas; Fries, Jill; Kalyanam, Ravi; Michael, Andrew M.; Caprihan, Arvind; Turner, Jessica A.; Eichele, Tom; Adelsheim, Steven; Bryan, Angela D.; Bustillo, Juan; Clark, Vincent P.; Feldstein Ewing, Sarah W.; Filbey, Francesca; Ford, Corey C.; Hutchison, Kent; Jung, Rex E.; Kiehl, Kent A.; Kodituwakku, Piyadasa; Komesu, Yuko M.; Mayer, Andrew R.; Pearlson, Godfrey D.; Phillips, John P.; Sadek, Joseph R.; Stevens, Michael; Teuscher, Ursina; Thoma, Robert J.; Calhoun, Vince D.

    2011-01-01

    As the size of functional and structural MRI datasets expands, it becomes increasingly important to establish a baseline from which diagnostic relevance may be determined, a processing strategy that efficiently prepares data for analysis, and a statistical approach that identifies important effects in a manner that is both robust and reproducible. In this paper, we introduce a multivariate analytic approach that optimizes sensitivity and reduces unnecessary testing. We demonstrate the utility of this mega-analytic approach by identifying the effects of age and gender on the resting-state networks (RSNs) of 603 healthy adolescents and adults (mean age: 23.4 years, range: 12–71 years). Data were collected on the same scanner, preprocessed using an automated analysis pipeline based in SPM, and studied using group independent component analysis. RSNs were identified and evaluated in terms of three primary outcome measures: time course spectral power, spatial map intensity, and functional network connectivity. Results revealed robust effects of age on all three outcome measures, largely indicating decreases in network coherence and connectivity with increasing age. Gender effects were of smaller magnitude but suggested stronger intra-network connectivity in females and more inter-network connectivity in males, particularly with regard to sensorimotor networks. These findings, along with the analysis approach and statistical framework described here, provide a useful baseline for future investigations of brain networks in health and disease. PMID:21442040

  8. The dry eye assessment and management (DREAM©) study: Study design and baseline characteristics.

    Science.gov (United States)

    Asbell, Penny A; Maguire, Maureen G; Peskin, Ellen; Bunya, Vatinee Y; Kuklinski, Eric J

    2018-06-05

    Describe trial design and baseline characteristics of participants in the DRy Eye Assessment and Management (DREAM©) Study. Prospective, multi-center, randomized, double-masked "real-world" clinical trial assessing efficacy and safety of oral omega-3 (ω3) supplementation for the treatment of dry eye disease (DED). RESULTS: Mean age of participants was 58.0 ± 13.2 years. Mean OSDI score at baseline was 44.4 ± 14.2. Mean conjunctival staining score (scale 0-6) was 3.0 ± 1.4, corneal staining score (scale 0-15) was 3.9 ± 2.7, tear break-up time was 3.1 ± 1.5 s, and Schirmer test was 9.6 ± 6.5 mm/5 min. DREAM© participants mirror real world patients who seek intervention for their DED-related symptoms despite their current treatments. Results regarding the efficacy of omega-3 supplementation will be helpful to clinicians and patients with moderate to severe DED who are considering omega-3 as a treatment. This trial design may be a model for future RCT's on nutritional supplements and DED treatments seeking to provide useful information for clinical practice. ClinicalTrials.gov number NCT02128763. Copyright © 2017. Published by Elsevier Inc.

  9. Sex Differences and Self-Reported Attention Problems During Baseline Concussion Testing.

    Science.gov (United States)

    Brooks, Brian L; Iverson, Grant L; Atkins, Joseph E; Zafonte, Ross; Berkner, Paul D

    2016-01-01

    Amateur athletic programs often use computerized cognitive testing as part of their concussion management programs. There is evidence that athletes with preexisting attention problems will have worse cognitive performance and more symptoms at baseline testing. The purpose of this study was to examine whether attention problems affect assessments differently for male and female athletes. Participants were drawn from a database that included 6,840 adolescents from Maine who completed Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) at baseline (primary outcome measure). The final sample included 249 boys and 100 girls with self-reported attention problems. Each participant was individually matched for sex, age, number of past concussions, and sport to a control participant (249 boys, 100 girls). Boys with attention problems had worse reaction time than boys without attention problems. Girls with attention problems had worse visual-motor speed than girls without attention problems. Boys with attention problems reported more total symptoms, including more cognitive-sensory and sleep-arousal symptoms, compared with boys without attention problems. Girls with attention problems reported more cognitive-sensory, sleep-arousal, and affective symptoms than girls without attention problems. When considering the assessment, management, and outcome from concussions in adolescent athletes, it is important to consider both sex and preinjury attention problems regarding cognitive test results and symptom reporting.

  10. Robust extraction of baseline signal of atmospheric trace species using local regression

    Science.gov (United States)

    Ruckstuhl, A. F.; Henne, S.; Reimann, S.; Steinbacher, M.; Vollmer, M. K.; O'Doherty, S.; Buchmann, B.; Hueglin, C.

    2012-11-01

    The identification of atmospheric trace species measurements that are representative of well-mixed background air masses is required for monitoring atmospheric composition change at background sites. We present a statistical method based on robust local regression that is well suited for the selection of background measurements and the estimation of associated baseline curves. The bootstrap technique is applied to calculate the uncertainty in the resulting baseline curve. The non-parametric nature of the proposed approach makes it a very flexible data filtering method. Application to carbon monoxide (CO) measured from 1996 to 2009 at the high-alpine site Jungfraujoch (Switzerland, 3580 m a.s.l.), and to measurements of 1,1-difluoroethane (HFC-152a) from Jungfraujoch (2000 to 2009) and Mace Head (Ireland, 1995 to 2009) demonstrates the feasibility and usefulness of the proposed approach. The determined average annual change of CO at Jungfraujoch for the 1996 to 2009 period as estimated from filtered annual mean CO concentrations is -2.2 ± 1.1 ppb yr-1. For comparison, the linear trend of unfiltered CO measurements at Jungfraujoch for this time period is -2.9 ± 1.3 ppb yr-1.

  11. Robust extraction of baseline signal of atmospheric trace species using local regression

    Directory of Open Access Journals (Sweden)

    A. F. Ruckstuhl

    2012-11-01

    Full Text Available The identification of atmospheric trace species measurements that are representative of well-mixed background air masses is required for monitoring atmospheric composition change at background sites. We present a statistical method based on robust local regression that is well suited for the selection of background measurements and the estimation of associated baseline curves. The bootstrap technique is applied to calculate the uncertainty in the resulting baseline curve. The non-parametric nature of the proposed approach makes it a very flexible data filtering method. Application to carbon monoxide (CO measured from 1996 to 2009 at the high-alpine site Jungfraujoch (Switzerland, 3580 m a.s.l., and to measurements of 1,1-difluoroethane (HFC-152a from Jungfraujoch (2000 to 2009 and Mace Head (Ireland, 1995 to 2009 demonstrates the feasibility and usefulness of the proposed approach.

    The determined average annual change of CO at Jungfraujoch for the 1996 to 2009 period as estimated from filtered annual mean CO concentrations is −2.2 ± 1.1 ppb yr−1. For comparison, the linear trend of unfiltered CO measurements at Jungfraujoch for this time period is −2.9 ± 1.3 ppb yr−1.

  12. Item analysis of ADAS-Cog: effect of baseline cognitive impairment in a clinical AD trial.

    Science.gov (United States)

    Sevigny, Jeffrey J; Peng, Yahong; Liu, Lian; Lines, Christopher R

    2010-03-01

    We explored the association of Alzheimer's disease (AD) Assessment Scale (ADAS-Cog) item scores with AD severity using cross-sectional and longitudinal data from the same study. Post hoc analyses were performed using placebo data from a 12-month trial of patients with mild-to-moderate AD (N =281 randomized, N =209 completed). Baseline distributions of ADAS-Cog item scores by Mini-Mental State Examination (MMSE) score and Clinical Dementia Rating (CDR) sum of boxes score (measures of dementia severity) were estimated using local and nonparametric regressions. Mixed-effect models were used to characterize ADAS-Cog item score changes over time by dementia severity (MMSE: mild =21-26, moderate =14-20; global CDR: mild =0.5-1, moderate =2). In the cross-sectional analysis of baseline ADAS-Cog item scores, orientation was the most sensitive item to differentiate patients across levels of cognitive impairment. Several items showed a ceiling effect, particularly in milder AD. In the longitudinal analysis of change scores over 12 months, orientation was the only item with noticeable decline (8%-10%) in mild AD. Most items showed modest declines (5%-20%) in moderate AD.

  13. Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Biewer, Theodore M. [ORNL; Marcus, Chris [ORNL; Klepper, C Christopher [ORNL; Andrew, Philip [ITER Organization, Cadarache, France; Gardner, W. L. [United States ITER Project Office; Graves, Van B. [ORNL; Hughes, Shaun [ITER Organization, Saint Paul Lez Durance, France

    2017-10-01

    The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \\textasciitilde 1 s response time from the sensor cluster [1].

  14. Are sawfishes still present in Mozambique? A baseline ecological study

    Directory of Open Access Journals (Sweden)

    Ruth H. Leeney

    2017-02-01

    Full Text Available Sawfishes (Pristidae were formerly abundant in the western Indian Ocean, but current data on sawfish presence and distribution are lacking for most of the region. This paper summarises historical records of sawfishes in Mozambican waters and presents the findings of the first assessment of the presence and status of sawfishes in Mozambique. A countrywide baseline assessment was undertaken between May and July 2014, using interviews with artisanal, semi-industrial and industrial fishers, fish traders and fisheries monitoring staff as the primary source of information on sawfish distribution, recent catches, socio-economic value and cultural importance. Additional interviews were conducted via email or telephone with individuals running sport fishing operations or who otherwise had considerable experience interacting with the fishing sectors or the marine environment in Mozambique. Where encountered, sawfish rostra were photographed and a series of measurements and associated data were collected. In total, 200 questionnaire surveys and seven interviews with recreational fishing and dive operators were conducted, and 19 rostra were documented from museum archives and private collections, belonging to two sawfish species, the Largetooth Sawfish (Pristis pristis and Green Sawfish (P. zijsron. The most recent captures of sawfishes were reported to have occurred in 2014. Two key sites were identified where both recent encounters were reported and numerous Largetooth Sawfish rostra were documented. Gill nets were the fishing gear most commonly attributed to sawfish catches. Sawfishes did not hold any cultural importance in Mozambique, but they have at least some socio-economic importance to artisanal fishers, primarily through the sale of their fins. The meat did not appear to be held in high regard and was usually consumed locally. Sampling and further research is now required to confirm the presence of sawfishes and to assess the primary threats to

  15. Are sawfishes still present in Mozambique? A baseline ecological study.

    Science.gov (United States)

    Leeney, Ruth H

    2017-01-01

    Sawfishes (Pristidae) were formerly abundant in the western Indian Ocean, but current data on sawfish presence and distribution are lacking for most of the region. This paper summarises historical records of sawfishes in Mozambican waters and presents the findings of the first assessment of the presence and status of sawfishes in Mozambique. A countrywide baseline assessment was undertaken between May and July 2014, using interviews with artisanal, semi-industrial and industrial fishers, fish traders and fisheries monitoring staff as the primary source of information on sawfish distribution, recent catches, socio-economic value and cultural importance. Additional interviews were conducted via email or telephone with individuals running sport fishing operations or who otherwise had considerable experience interacting with the fishing sectors or the marine environment in Mozambique. Where encountered, sawfish rostra were photographed and a series of measurements and associated data were collected. In total, 200 questionnaire surveys and seven interviews with recreational fishing and dive operators were conducted, and 19 rostra were documented from museum archives and private collections, belonging to two sawfish species, the Largetooth Sawfish ( Pristis pristis) and Green Sawfish ( P. zijsron) . The most recent captures of sawfishes were reported to have occurred in 2014. Two key sites were identified where both recent encounters were reported and numerous Largetooth Sawfish rostra were documented. Gill nets were the fishing gear most commonly attributed to sawfish catches. Sawfishes did not hold any cultural importance in Mozambique, but they have at least some socio-economic importance to artisanal fishers, primarily through the sale of their fins. The meat did not appear to be held in high regard and was usually consumed locally. Sampling and further research is now required to confirm the presence of sawfishes and to assess the primary threats to sawfishes in

  16. High baseline activity in inferior temporal cortex improves neural and behavioral discriminability during visual categorization

    Science.gov (United States)

    Emadi, Nazli; Rajimehr, Reza; Esteky, Hossein

    2014-01-01

    Spontaneous firing is a ubiquitous property of neural activity in the brain. Recent literature suggests that this baseline activity plays a key role in perception. However, it is not known how the baseline activity contributes to neural coding and behavior. Here, by recording from the single neurons in the inferior temporal cortex of monkeys performing a visual categorization task, we thoroughly explored the relationship between baseline activity, the evoked response, and behavior. Specifically we found that a low-frequency (baseline activity. This enhancement of the baseline activity was then followed by an increase in the neural selectivity and the response reliability and eventually a higher behavioral performance. PMID:25404900

  17. Neoadjuvant chemoradiotherapy of rectal carcinoma. Baseline hematologic parameters influencing outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Hodek, Miroslav; Sirak, Igor; Paluska, Petr; Kopecky, Jindrich; Petera, Jiri; Vosmik, Milan [University Hospital in Hradec Kralove, Department of Oncology and Radiotherapy, Hradec Kralove (Czech Republic); Ferko, Alexander; Oerhalmi, Julius [University Hospital in Hradec Kralove, Department of Surgery, Hradec Kralove (Czech Republic); Hovorkova, Eva; Hadzi Nikolov, Dimitar [University Hospital in Hradec Kralove, Fingerland Department of Pathology, Hradec Kralove (Czech Republic)

    2016-09-15

    The link between the blood count and a systemic inflammatory response (SIR) is indisputable and well described. Pretreatment hematological parameters may predict the overall clinical outcomes in many types of cancer. Thus, this study aims to systematically evaluate the relationship between baseline blood count levels and treatment response in rectal cancer patients treated with neoadjuvant chemoradiotherapy. From 2009-2015, 173 patients with locally advanced rectal cancer were retrospectively enrolled in the study and analyzed. The baseline blood count was recorded in all patients 1 week before chemoradiation. Tumor response was evaluated through pathologic findings. Blood count levels which included RBC (red blood cells), Hb (hemoglobin), PLT (platelet count), neutrophil count, WBC (white blood cells), NLR (neutrophil-to-lymphocyte ratio), and PLR (platelet-to-lymphocyte ratio) were analyzed in relation to tumor downstaging, pCR (pathologic complete response), OS (overall survival), and DFS (disease-free survival). Hb levels were associated with a response in logistic regression analysis: pCR (p = 0.05; OR 1.04, 95 % CI 1.00-1.07); T downstaging (p = 0.006; OR 1.03, 95 % CI 1.01-1.05); N downstaging (p = 0.09; OR 1.02, 95 % CI 1.00-1.04); T or N downstaging (p = 0.007; OR 1.04, 95 % CI 1.01-1.07); T and N downstaging (p = 0.02; OR 1.02, 95 % CI 1.00-1.04); Hb and RBC were the most significant parameters influencing OS; PLT was a negative prognostic factor for OS and DFS (p = 0.008 for OS); an NLR value of 2.8 was associated with the greatest significance for OS (p = 0.03) and primary tumor downstaging (p = 0.02). Knowledge of pretreatment hematological parameters appears to be an important prognostic factor in patients with rectal carcinoma. (orig.) [German] Die Verbindung zwischen dem Blutbild und der systemischen Entzuendungsreaktion (''systemic inflammatory response'', SIR) ist unbestreitbar und gut beschrieben. Aufgrund der

  18. Cumulative Effects of Concussion History on Baseline Computerized Neurocognitive Test Scores: Systematic Review and Meta-analysis.

    Science.gov (United States)

    Alsalaheen, Bara; Stockdale, Kayla; Pechumer, Dana; Giessing, Alexander; He, Xuming; Broglio, Steven P

    It is unclear whether individuals with a history of single or multiple clinically recovered concussions exhibit worse cognitive performance on baseline testing compared with individuals with no concussion history. To analyze the effects of concussion history on baseline neurocognitive performance using a computerized neurocognitive test. PubMed, CINAHL, and psycINFO were searched in November 2015. The search was supplemented by a hand search of references. Studies were included if participants completed the Immediate Post-concussion Assessment and Cognitive Test (ImPACT) at baseline (ie, preseason) and if performance was stratified by previous history of single or multiple concussions. Systematic review and meta-analysis. Level 2. Sample size, demographic characteristics of participants, as well as performance of participants on verbal memory, visual memory, visual-motor processing speed, and reaction time were extracted from each study. A random-effects pooled meta-analysis revealed that, with the exception of worsened visual memory for those with 1 previous concussion (Hedges g = 0.10), no differences were observed between participants with 1 or multiple concussions compared with participants without previous concussions. With the exception of decreased visual memory based on history of 1 concussion, history of 1 or multiple concussions was not associated with worse baseline cognitive performance.

  19. Scheme for generating and transporting THz radiation to the X-ray experimental floor at LCLS baseline

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-08-15

    This paper describes a novel scheme for integrating a coherent THz source in the baseline of the LCLS facility. Any method relying on the spent electron beam downstream of the baseline undulator should provide a way of transporting the radiation up to the experimental floor.Herewe propose to use the dump area access maze. In this way the THz output must propagate with limited size at least for one hundred meters in a maze, following many turns, to reach the near experimental hall. The use of a standard, discrete, open beam-waveguide formed by periodic reflectors, that is a mirror guide, would lead to unacceptable size of the system. To avoid these problems, in this paper we propose an alternative approach based on periodically spaced metallic screens with holes. This quasi-optical transmission line is referred to as an iris line. We present complete calculations for the iris line using both analytical and numerical methods, which we find in good agreement. We present a design of a THz edge radiation source based on the use of an iris line. The proposed setup takes almost no cost nor time to be implemented at the LCLS baseline, and can be used at other facilities as well. The edge radiation source is limited in maximally achievable field strength at the sample. An extension based on the use of an undulator in the presence of the iris line, which is feasible at the LCLS energies, is proposed as a possible upgrade of the baseline THz source. (orig)

  20. Scheme for generating and transporting THz radiation to the X-ray experimental floor at LCLS baseline

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-08-01

    This paper describes a novel scheme for integrating a coherent THz source in the baseline of the LCLS facility. Any method relying on the spent electron beam downstream of the baseline undulator should provide a way of transporting the radiation up to the experimental floor.Herewe propose to use the dump area access maze. In this way the THz output must propagate with limited size at least for one hundred meters in a maze, following many turns, to reach the near experimental hall. The use of a standard, discrete, open beam-waveguide formed by periodic reflectors, that is a mirror guide, would lead to unacceptable size of the system. To avoid these problems, in this paper we propose an alternative approach based on periodically spaced metallic screens with holes. This quasi-optical transmission line is referred to as an iris line. We present complete calculations for the iris line using both analytical and numerical methods, which we find in good agreement. We present a design of a THz edge radiation source based on the use of an iris line. The proposed setup takes almost no cost nor time to be implemented at the LCLS baseline, and can be used at other facilities as well. The edge radiation source is limited in maximally achievable field strength at the sample. An extension based on the use of an undulator in the presence of the iris line, which is feasible at the LCLS energies, is proposed as a possible upgrade of the baseline THz source. (orig)

  1. Esophageal intraluminal baseline impedance is associated with severity of acid reflux and epithelial structural abnormalities in patients with gastroesophageal reflux disease.

    Science.gov (United States)

    Zhong, Chanjuan; Duan, Liping; Wang, Kun; Xu, Zhijie; Ge, Ying; Yang, Changqing; Han, Yajing

    2013-05-01

    The esophageal intraluminal baseline impedance may be used to evaluate the status of mucosa integrity. Esophageal acid exposure decreases the baseline impedance. We aimed to compare baseline impedance in patients with various reflux events and with different acid-related parameters, and investigate the relationships between epithelial histopathologic abnormalities and baseline impedance. A total of 229 GERD patients and 34 controls underwent 24-h multichannel intraluminal impedance and pH monitoring (MII-pH monitoring), gastroendoscopy, and completed a GERD questionnaire (GerdQ). We quantified epithelial intercellular spaces (ICSs) and expression of tight junction (TJ) proteins by histologic techniques. Mean baseline values in reflux esophagitis (RE) (1752 ± 1018 Ω) and non-erosive reflux disease (NERD) (2640 ± 1143 Ω) were significantly lower than in controls (3360 ± 1258 Ω; p acid reflux group (2510 ± 1239 Ω) and mixed acid/weakly acidic reflux group (2393 ± 1009 Ω) were much lower than in controls (3360 ± 1258 Ω; p = 0.020 and p acid exposure time (AET) (r = -0.41, p acid reflux events and with longer AET have low baseline impedance. Baseline values are correlated with esophageal mucosal histopathologic changes such as dilated ICS and TJ alteration.

  2. Baseline concentration of {sup 210}Po in Sargassum from the Northern Gulf

    Energy Technology Data Exchange (ETDEWEB)

    Uddin, S.; Bebhehani, M.; Talebi, L. [Kuwait Institute for Scientific Research (Kuwait)

    2014-07-01

    The concentration of the {sup 210}Po is of enormous interest because of its large contribution to the natural radiation dose received by marine organisms and human populations consuming seafood. In fact natural {sup 210}Po is responsible for higher radiation doses to humans consuming marine products than is plutonium and other man-made radionuclides. Many marine organisms are capable of concentrating {sup 210}Po in their tissues. {sup 210}Po is an alpha emitter in the {sup 238}U series, with 138-d half-life, that is supplied to seawater from atmospheric inputs and river runoff, however, the main source of {sup 210}Po in the environment is {sup 222}Rn exhalation from the ground. Assessing the impact of radionuclides in the environment requires the establishment of baseline levels in the environmental compartments. The objective of this study was to establish baseline levels in Sargassum. Two most common species of Sargassum found in the northern Gulf were analysed for {sup 210}Po. These macro-algae were collected from three different locations during January 2013. This study sets the baseline for {sup 210}Po concentration in northern Gulf, {sup 210}Po is absorbed from water and concentrated by Phytoplankton and macro-algae. This concentrated {sup 210}Po can then be passed along to the next trophic level of the marine food web. The {sup 210}Po concentration measured in Sargassum boveanum (4.405 - 4.952 BqKg{sup -1}) was significantly higher (p>0.084) than Sargassum oligocystum (3.838 - 4.358 BqKg{sup -1}). The {sup 210}Po concentration in these seaweeds from the Arabian/Persian Gulf were substantially lower than those found in various Phytoplankton and macro-algae species from other regions; this may be due to the lower background {sup 210}Po concentration in the Kuwait marine waters (0.282 - 0.382 mBq l{sup -1}). The {sup 210}Po concentrations in seawater measured at the 3 stations during January 2013 were less than those reported previously from the same region

  3. [The prognostic value of baseline serum free light chain in cardiac amyloidosis].

    Science.gov (United States)

    Zhao, Lei; Tian, Zhuang; Fang, Quan

    2016-03-01

    To analyze the prognostic value of baseline serum free light chain (sFLC) in light-chain (AL) cardiac amyloidosis. Twenty-seven patients with AL cardiac amyloidosis were retrospectively reviewed from January 2014 to January 2015. sFLC was measured by immuoturbidimetric assay. Baseline characteristics, echocardiographic parameters and electrocardiogram data were analyzed. According to the median baseline dFLC (involved sFLC minus uninvolved sFLC), patients were categorized into either the low dFLC(≤ 307 mg/L) or the high dFLC group (>307 mg/L). More subjects in the high dFLC group with early/late diastolic mitral velocity ratio (E/A ratio) over 2 (71.4% vs 30.8%, P=0.035), and subjects in this group had a shorter median survival time than those in the low dFLC group (3 months vs 17 months, P=0.004). A similar phenomenon for median survival time was observed when the subjects were redivided either by a new cut-off value of 180 mg/L for dFLC (low dFLC group: 17 months; high dFLC group: 4 months, P=0.014) or a κ/λ ratio, in which subjects with κ type sFLC-ratio ≤ 19.6 and λ type sFLC-ratio>0.065 were in the low sFLC-ratio group (17 months) and those with κ type sFLC-ratio > 19.6 and λ type sFLC-ratio ≤ 0.065 were in the high sFLC-ratio group (4 months, P=0.023). In multivariate analysis, dFLC and New York Heart Association (NYHA)classification of cardiac function were two risk factors associated with all-cause mortality in patients, among which the hazard ratio for higher dFLC was 4.28 (95%CI 1.55-11.8, P=0.005). The level of sFLC could be a marker for the prognosis of AL cardiac amyloidosis.

  4. Evolved Phenological Asynchrony as a Baseline for Climate-change Impacts. (Invited)

    Science.gov (United States)

    Singer, M. C.; Parmesan, C.

    2010-12-01

    Changing climate can disrupt existing phenological relations between interacting species. We might expect the historical baseline for these effects to be precise synchrony between the season at which a consumer most requires food and the time when its resources are most available. When this is the case, change in any direction would be detrimental to the consumer. But is baseline synchrony the appropriate assumption? Here, we develop the theme that the starting point for climate change impacts may often have been asynchrony or mismatch between consumer and resource. To the extent that this has been true, assumptions of baseline synchrony risk mis-detection, mis-estimation, and mis-attribution of climate change impacts. Natural selection can result in asynchrony between exploiter and victim when victims successfully evolve to occupy enemy-free time. Asynchrony can also result from life-history tradedoffs. We illustrate asynchrony arising from tradeoffs for two species: Edith’s checkerspot butterfly and the winter moth. Initial observations of phenological mismatch in both systems were made prior to the onset of major impacts of anthropogenically-driven climate change. Neither species can detect the phenological stage of its host plants with precision. In both species, evolution of life history has involved compromise between maximizing fecundity and minimizing mortality, with the outcome being superficially maladaptive strategies in which many or even most individuals die of starvation through poor synchrony with their host plants. Both species have evolved high-risk life history strategies. While winter moth eggs gamble with their own lives by hatching early, bay checkerspots gamble with the lives of their offspring by growing large and eclosing late as adults. In both cases the result is the evolution of populations in which large numbers of individuals die because, as individuals, they fail to fit their life cycles into the available timespan. Because such a

  5. Three-dimensional thermal analysis of a baseline spent fuel repository

    International Nuclear Information System (INIS)

    Altenbach, T.J.; Lowry, W.E.

    1980-01-01

    A three-dimensional thermal analysis has been performed using finite difference techniques to determine the near-field response of a baseline spent fuel repository in a deep geologic salt medium. A baseline design incorporates previous thermal modeling experience and OWI recommendations for areal thermal loading in specifying the waste form properties, package details, and emplacement configuration. The base case in this thermal analysis considers one 10-year old PWR spent fuel assembly emplaced to yield a 36 kw/acre (8.9 w/m 2 ) loading. A unit cell model in an infinite array is used to simplify the problem and provide upper-bound temperatures. Boundary conditions are imposed which allow simulations to 1000 years. Variations studied include a comparison of ventilated and unventilated storage room conditions, emplacement packages with and without air gaps surrounding the canister, and room cool-down scenarios with ventilation following an unventilated state for retrieval purposes. At this low power level ventilating the emplacement room has an immediate cooling influence on the canister and effectively maintains the emplacement room floor near the temperature of the ventilating air. The annular gap separating the canister and sleeve causes the peak temperature of the canister surface to rise by 10 0 F (5.6 0 C) over that from a no gap case assuming perfect thermal contact. It was also shown that the time required for the emplacement room to cool down to 100 0 F (38 0 C) from an unventilated state ranged from 2 weeks to 6 months; when ventilation initiated after times of 5 years to 50 years, respectively. As the work was performed for the Nuclear Regulatory Commission, these results provide a significant addition to the regulatory data base for spent fuel performance in a geologic repository

  6. A Multi-Baseline 12 GHz Atmospheric Phase Interferometer with One Micron Path Length Sensitivity

    Science.gov (United States)

    Kimberk, Robert S.; Hunter, Todd R.; Leiker, Patrick S.; Blundell, Raymond; Nystrom, George U.; Petitpas, Glen R.; Test, John; Wilson, Robert W.; Yamaguchi, Paul; Young, Kenneth H.

    2012-12-01

    We have constructed a five station 12 GHz atmospheric phase interferometer (API) for the Submillimeter Array (SMA) located near the summit of Mauna Kea, Hawaii. Operating at the base of unoccupied SMA antenna pads, each station employs a commercial low noise mixing block coupled to a 0.7 m off-axis satellite dish which receives a broadband, white noise-like signal from a geostationary satellite. The signals are processed by an analog correlator to produce the phase delays between all pairs of stations with projected baselines ranging from 33-261 m. Each baseline's amplitude and phase is measured continuously at a rate of 8 kHz, processed, averaged and output at 10 Hz. Further signal processing and data reduction is accomplished with a Linux computer, including the removal of the diurnal motion of the target satellite. The placement of the stations below ground level with an environmental shield combined with the use of low temperature coefficient, buried fiber optic cables provides excellent system stability. The sensitivity in terms of rms path length is 1.3 microns which corresponds to phase deviations of about 1° of phase at the highest operating frequency of the SMA. The two primary data products are: (1) standard deviations of observed phase over various time scales, and (2) phase structure functions. These real-time statistical data measured by the API in the direction of the satellite provide an estimate of the phase front distortion experienced by the concurrent SMA astronomical observations. The API data also play an important role, along with the local opacity measurements and weather predictions, in helping to plan the scheduling of science observations on the telescope.

  7. Baseline assessment of groundwater quality in Pike County, Pennsylvania, 2015

    Science.gov (United States)

    Senior, Lisa A.; Cravotta, Charles A.

    2017-12-29

    The Devonian-age Marcellus Shale and the Ordovician-age Utica Shale, which have the potential for natural gas development, underlie Pike County and neighboring counties in northeastern Pennsylvania. In 2015, the U.S. Geological Survey, in cooperation with the Pike County Conservation District, conducted a study that expanded on a previous more limited 2012 study to assess baseline shallow groundwater quality in bedrock aquifers in Pike County prior to possible extensive shale-gas development. Seventy-nine water wells ranging in depths from 80 to 610 feet were sampled during June through September 2015 to provide data on the presence of methane and other aspects of existing groundwater quality in the various bedrock geologic units throughout the county, including concentrations of inorganic constituents commonly present at low values in shallow, fresh groundwater but elevated in brines associated with fluids extracted from geologic formations during shale-gas development. All groundwater samples collected in 2015 were analyzed for bacteria, dissolved and total major ions, nutrients, selected dissolved and total inorganic trace constituents (including metals and other elements), radon-222, gross alpha- and gross beta-particle activity, dissolved gases (methane, ethane, and propane), and, if sufficient methane was present, the isotopic composition of methane. Additionally, samples from 20 wells distributed throughout the county were analyzed for selected man-made volatile organic compounds, and samples from 13 wells where waters had detectable gross alpha activity were analyzed for radium-226 on the basis of relatively elevated gross alpha-particle activity.Results of the 2015 study show that groundwater quality generally met most drinking-water standards for constituents and properties included in analyses, but groundwater samples from some wells had one or more constituents or properties, including arsenic, iron, manganese, pH, bacteria, sodium, chloride, sulfate

  8. Baseline assessment of groundwater quality in Wayne County, Pennsylvania, 2014

    Science.gov (United States)

    Senior, Lisa A.; Cravotta, III, Charles A.; Sloto, Ronald A.

    2016-06-30

    The Devonian-age Marcellus Shale and the Ordovician-age Utica Shale, geologic formations which have potential for natural gas development, underlie Wayne County and neighboring counties in northeastern Pennsylvania. In 2014, the U.S. Geological Survey, in cooperation with the Wayne Conservation District, conducted a study to assess baseline shallow groundwater quality in bedrock aquifers in Wayne County prior to potential extensive shale-gas development. The 2014 study expanded on previous, more limited studies that included sampling of groundwater from 2 wells in 2011 and 32 wells in 2013 in Wayne County. Eighty-nine water wells were sampled in summer 2014 to provide data on the presence of methane and other aspects of existing groundwater quality throughout the county, including concentrations of inorganic constituents commonly present at low levels in shallow, fresh groundwater but elevated in brines associated with fluids extracted from geologic formations during shale-gas development. Depths of sampled wells ranged from 85 to 1,300 feet (ft) with a median of 291 ft. All of the groundwater samples collected in 2014 were analyzed for bacteria, major ions, nutrients, selected inorganic trace constituents (including metals and other elements), radon-222, gross alpha- and gross beta-particle activity, selected man-made organic compounds (including volatile organic compounds and glycols), dissolved gases (methane, ethane, and propane), and, if sufficient methane was present, the isotopic composition of methane.Results of the 2014 study show that groundwater quality generally met most drinking-water standards, but some well-water samples had one or more constituents or properties, including arsenic, iron, pH, bacteria, and radon-222, that exceeded primary or secondary maximum contaminant levels (MCLs). Arsenic concentrations were higher than the MCL of 10 micrograms per liter (µg/L) in 4 of 89 samples (4.5 percent) with concentrations as high as 20 µg/L; arsenic

  9. Stack Characterization in CryoSat Level1b SAR/SARin Baseline C

    Science.gov (United States)

    Scagliola, Michele; Fornari, Marco; Di Giacinto, Andrea; Bouffard, Jerome; Féménias, Pierre; Parrinello, Tommaso

    2015-04-01

    CryoSat was launched on the 8th April 2010 and is the first European ice mission dedicated to the monitoring of precise changes in the thickness of polar ice sheets and floating sea ice. CryoSat is the first altimetry mission operating in SAR mode and it carries an innovative radar altimeter called the Synthetic Aperture Interferometric Altimeter (SIRAL), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. The current CryoSat IPF (Instrument Processing Facility), Baseline B, was released in operation in February 2012. After more than 2 years of development, the release in operations of the Baseline C is expected in the first half of 2015. It is worth recalling here that the CryoSat SAR/SARin IPF1 generates 20Hz waveforms in correspondence of an approximately equally spaced set of ground locations on the Earth surface, i.e. surface samples, and that a surface sample gathers a collection of single-look echoes coming from the processed bursts during the time of visibility. Thus, for a given surface sample, the stack can be defined as the collection of all the single-look echoes pointing to the current surface sample, after applying all the necessary range corrections. The L1B product contains the power average of all the single-look echoes in the stack: the multi-looked L1B waveform. This reduces the data volume, while removing some information contained in the single looks, useful for characterizing the surface and modelling the L1B waveform. To recover such information, a set of parameters has been added to the L1B product: the stack characterization or beam behaviour parameters. The stack characterization, already included in previous Baselines, has been reviewed and expanded in Baseline C. This poster describes all the stack characterization parameters, detailing what they represent and how they have been computed. In details, such parameters can be summarized in: - Stack

  10. Early return to baseline range of motion and strength after anterior shoulder instability surgery: a Multicenter Orthopaedic Outcomes Network (MOON) shoulder group cohort study.

    Science.gov (United States)

    Buckwalter V, Joseph A; Wolf, Brian R; Glass, Natalie; Bollier, Matt; Kuhn, John E; Hettrich, Carolyn M

    2018-03-23

    Patients often return to higher-level activities and sports at 4 to 8 months after anterior shoulder stabilization procedures. It is unknown what percentage of patients have regained normal function at this time frame and what factors predict residual deficits, range of motion (ROM), and strength after anterior shoulder instability surgery. Ten participating sites throughout the United States enrolled patients in a prospective cohort study including primary, revision, arthroscopic, and open anterior stabilization procedures. Baseline demographic data and patient outcomes questionnaires were collected with initial physical examination, treatment, surgical findings, and surgical repair details. At the 6-month follow-up visit, ROM and strength measurements were collected and compared with preoperative measurements. There were 348 patients identified who underwent surgical treatment for anterior shoulder instability. Of these, 259 patients (74.0%) returned to baseline, and 89 (26.0%) did not return to baseline shoulder ROM (≥20° loss of ROM) or strength. A higher Beighton score (P = .01) and number of dislocations (P baseline ROM and strength at early follow-up. No surgical variables were found to influence return to baseline function, including open vs. arthroscopic surgery, primary vs. revision surgery, and number of suture anchors. By 4 to 8 months postoperatively, 76% of patients return to baseline ROM, 98% return to baseline strength, and 74% return to both baseline ROM and strength. An increased number of dislocations and generalized joint laxity were associated with failure to return to baseline ROM and strength at early follow-up after anterior shoulder instability surgery. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Effects of Baseline Selection on Magnetocardiography: P-Q and T-P Intervals

    International Nuclear Information System (INIS)

    Lim, Hyun Kyoon; Kwon, Hyuk Chan; Kim, Tae En; Lee, Yong Ho; Kim, Jin Mok; Kim, In Seon; Kim, Ki Woong; Park, Yong Ki

    2007-01-01

    The baseline selection is the first and important step to analyze magnetocardiography (MCG) parameters. There are no difficulties to select the baseline between P- and Q-wave peak (P-Q interval) of MCG wave recorded from healthy subjects because the P-Q intervals of the healthy subjects do not much vary. However, patients with ischemic heart disease often show an unstable P-Q interval which does not seem to be appropriate for the baseline. In this case, T-P interval is alternatively recommended for the baseline. However, there has been no study on the difference made by the baseline selection. In this study, we studied the effect of the different baseline selection. MCG data were analyzed from twenty healthy subjects and twenty one patients whose baselines were alternatively selected in the T-P interval for their inappropriate P-Q interval. Paired T-test was used to compare two set of data. Fifteen parameters derived from the R-wave peak, the T-wave peak, and the period, T max/3 ∼ T max were compared for the different baseline selection. As a result, most parameters did not show significant differences (p>0.05) except few parameters. Therefore, there will be no significant differences if anyone of two intervals were selected for the MCG baseline. However, for the consistent analysis, P-Q interval is strongly recommended for the baseline correction.

  12. Determining Baseline Stress-Related Hormone Values in Large Cetaceans

    Science.gov (United States)

    2015-09-30

    levels will be transformative for our understanding of the extent of exposure and the potential effect on the health of these animals and offers...cerumen as well as blubber from the same animal . While blubber cortisol concentrations will be a reflection of an indistinguishable time frame from...of the samples collected thus far from both museum holdings as well as fresh carcass samples. It should be noted that as part of our collection we

  13. Effect of water deprivation on baseline and stress-induced corticosterone levels in the Children's python (Antaresia childreni).

    Science.gov (United States)

    Dupoué, Andréaz; Angelier, Frédéric; Lourdais, Olivier; Bonnet, Xavier; Brischoux, François

    2014-02-01

    Corticosterone (CORT) secretion is influenced by endogenous factors (e.g., physiological status) and environmental stressors (e.g., ambient temperature). Heretofore, the impact of water deprivation on CORT plasma levels has not been thoroughly investigated. However, both baseline CORT and stress-induced CORT are expected to respond to water deprivation not only because of hydric stress per se, but also because CORT is an important mineralocorticoid in vertebrates. We assessed the effects of water deprivation on baseline CORT and stress-induced CORT, in Children's pythons (Antaresia childreni), a species that experiences seasonal droughts in natural conditions. We imposed a 52-day water deprivation on a group of unfed Children's pythons (i.e., water-deprived treatment) and provided water ad libitum to another group (i.e., control treatment). We examined body mass variations throughout the experiment, and baseline CORT and stress-induced CORT at the end of the treatments. Relative body mass loss averaged ~10% in pythons without water, a value 2 to 4 times higher compared to control snakes. Following re-exposition to water, pythons from the water-deprived treatment drank readily and abundantly and attained a body mass similar to pythons from the control treatment. Together, these results suggest a substantial dehydration as a consequence of water deprivation. Interestingly, stress-induced but not baseline CORT level was significantly higher in water-deprived snakes, suggesting that baseline CORT might not respond to this degree of dehydration. Therefore, possible mineralocorticoid role of CORT needs to be clarified in snakes. Because dehydration usually induces adjustments (reduced movements, lowered body temperature) to limit water loss, and decreases locomotor performances, elevated stress-induced CORT in water-deprived snakes might therefore compensate for altered locomotor performances. Future studies should test this hypothesis. Copyright © 2013 Elsevier Inc

  14. Baseline psychophysiological and cortisol reactivity as a predictor of PTSD treatment outcome in virtual reality exposure therapy.

    Science.gov (United States)

    Norrholm, Seth Davin; Jovanovic, Tanja; Gerardi, Maryrose; Breazeale, Kathryn G; Price, Matthew; Davis, Michael; Duncan, Erica; Ressler, Kerry J; Bradley, Bekh; Rizzo, Albert; Tuerk, Peter W; Rothbaum, Barbara O

    2016-07-01

    Baseline cue-dependent physiological reactivity may serve as an objective measure of posttraumatic stress disorder (PTSD) symptoms. Additionally, prior animal model and psychological studies would suggest that subjects with greatest symptoms at baseline may have the greatest violation of expectancy to danger when undergoing exposure based psychotherapy; thus treatment approaches which enhanced the learning under these conditions would be optimal for those with maximal baseline cue-dependent reactivity. However methods to study this hypothesis objectively are lacking. Virtual reality (VR) methodologies have been successfully employed as an enhanced form of imaginal prolonged exposure therapy for the treatment of PTSD. Our goal was to examine the predictive nature of initial psychophysiological (e.g., startle, skin conductance, heart rate) and stress hormone responses (e.g., cortisol) during presentation of VR-based combat-related stimuli on PTSD treatment outcome. Combat veterans with PTSD underwent 6 weeks of VR exposure therapy combined with either d-cycloserine (DCS), alprazolam (ALP), or placebo (PBO). In the DCS group, startle response to VR scenes prior to initiation of treatment accounted for 76% of the variance in CAPS change scores, p < 0.001, in that higher responses predicted greater changes in symptom severity over time. Additionally, baseline cortisol reactivity was inversely associated with treatment response in the ALP group, p = 0.04. We propose that baseline cue-activated physiological measures will be sensitive to predicting patients' level of response to exposure therapy, in particular in the presence of enhancement (e.g., DCS). Published by Elsevier Ltd.

  15. Changes in vitamin D supplement use and baseline plasma 25-hydroxyvitamin D concentration predict 5-y change in concentration in postmenopausal women.

    Science.gov (United States)

    Kluczynski, Melissa A; Wactawski-Wende, Jean; Platek, Mary E; DeNysschen, Carol A; Hovey, Kathleen M; Millen, Amy E

    2012-09-01

    Few studies have prospectively examined predictors of change in plasma concentrations of 25-hydroxyvitamin D [25(OH)D]. We sought to determine the predictors of 5-y change in 25(OH)D. Plasma 25(OH)D concentrations were assessed at baseline (1997-2000) and 5 y later (2002-2005) in 668 postmenopausal women enrolled in the Osteoporosis and Periodontal Disease Study. Baseline and changes in demographic, dietary, lifestyle, and health-related factors were tested as predictors of change in 25(OH)D concentrations by using multivariable linear regression. The mean 5-y change in 25(OH)D (mean ± SD) was 7.7 ± 0.7 nmol/L (P D concentrations and included baseline 25(OH)D, baseline and change in vitamin D supplementation and physical activity, change in season of blood draw, BMI, whole-body T score, and baseline hormone therapy use. Baseline 25(OH)D and change in vitamin D supplementation explained the most variation (25%) in 25(OH)D. Exploratory analyses showed a borderline significant interaction between tertiles of baseline 25(OH)D and change in vitamin D supplementation over time (P = 0.06). The greatest mean increase in 25(OH)D (22.9 ± 16.8 nmol/L), with adjustment for other statistically significant predictors, occurred in women whose baseline 25(OH)D concentration was ≤51.0 nmol/L (tertile 1) and who increased supplementation use over time. These results confirm the importance of supplementation in increasing 25(OH)D concentrations in aging women, even after other statistically significant predictors are controlled for. These data also suggest that this is especially true among aging women with inadequate 25(OH)D (e.g., <50 nmol/L).

  16. Establishing an anthropogenic nitrogen baseline using Native American shell middens

    Directory of Open Access Journals (Sweden)

    Autumn eOczkowski

    2016-05-01

    Full Text Available Narragansett Bay, Rhode Island, has been heavily influenced by anthropogenic nutrients for more than 200 years. Recent efforts to improve water quality have cut sewage nitrogen (N loads to this point source estuary by more than half. Given that the bay has been heavily fertilized for longer than monitoring programs have been in place, we sought additional insight into how N dynamics in the system have historically changed. To do this, we measured the N stable isotope (δ15N values in clam shells from as early as 3000 BP to the present. Samples from Native American middens were compared with those collected locally from museums, an archaeological company, and graduate student thesis projects, during a range of time periods. Overall, δ15N values in clam shells from Narragansett Bay have increased significantly over time, reflecting known patterns of anthropogenic nutrient enrichment. Pre-colonization midden shell δ15N values were significantly lower than those post-European contact. While there were no statistical differences among shells dated from the late 15th Century to 2005, there was a significant difference between 2005 and 2015 shells, which we attribute to the higher δ15N values in the effluent associated with recent sewage treatment upgrades. In contrast, the δ15N values of shells from the southern Rhode Island coast remained constant through time; while influenced by human activities, these areas are not directly influenced by point-source sewage discharge. Overall, our results show that this isotope technique for measuring δ15N values in clam shells provides useful insight into how N dynamics in coastal ecosystems have changed during thousands of years, providing managers vital historical information when setting goals for N reduction.

  17. Carbon intensity of electricity generation and CDM baseline: case studies of three Chinese provinces

    International Nuclear Information System (INIS)

    Zhang Chi; Heller, T.C.; May, M.M.

    2005-01-01

    A difficult and persistent issue in the discussion of Clean Development Mechanism is estimating a carbon emissions baseline, against which tradable permits may be certified. This paper examines the proposition of adopting sectoral, as opposed to project level, baselines by conducting case studies of the electricity industry in three Chinese provinces. We find that complicated central planning, financial and institutional factors have been behind the declining trend of carbon intensity in electricity generation and its provincial variations. Government planned electricity development which incorporates many of these factors and the associated industry carbon intensity may serve as a second best baseline. However, the limitation of the baseline we examine in this study plus difficulties numerous studies have revealed in baseline setting suggests that using baselines based on counterfactuals of what would happen will in the end either miss good emission reduction opportunities, or compromise the integrity of the regime

  18. Probing neutrino oscillations jointly in long and very long baseline experiments

    International Nuclear Information System (INIS)

    Wang, Y.F.; Whisnant, K.; Young Binglin; Xiong Zhaohua; Yang Jinmin

    2002-01-01

    We examine the prospects of making a joint analysis of neutrino oscillations at two baselines with neutrino superbeams. Assuming narrow band superbeams and a 100 kiloton water Cherenkov calorimeter, we calculate the event rates and sensitivities to the matter effect, the signs of the neutrino mass differences, the CP phase, and the mixing angle θ 13 . Taking into account all possible experimental errors under general consideration, we explore the optimum cases of a narrow band beam to measure the matter effect and the CP violation effect at all baselines up to 3000 km. We then focus on two specific baselines, a long baseline of 300 km and a very long baseline of 2100 km, and analyze their joint capabilities. We find that the joint analysis can offer extra leverage to resolve some of the ambiguities that are associated with the measurement at a single baseline

  19. Very long baseline interferometry applied to polar motion, relativity, and geodesy. Ph.D. thesis

    International Nuclear Information System (INIS)

    Ma, C.

    1978-01-01

    The causes and effects of diurnal polar motion are described. An algorithm was developed for modeling the effects on very long baseline interferometry observables. A selection was made between two three-station networks for monitoring polar motion. The effects of scheduling and the number of sources observed on estimated baseline errors are discussed. New hardware and software techniques in very long baseline interferometry are described

  20. Should Studies of Diabetes Treatment Stratification Correct for Baseline HbA1c?

    Science.gov (United States)

    Jones, Angus G.; Lonergan, Mike; Henley, William E.; Pearson, Ewan R.; Hattersley, Andrew T.; Shields, Beverley M.

    2016-01-01

    Aims Baseline HbA1c is a major predictor of response to glucose lowering therapy and therefore a potential confounder in studies aiming to identify other predictors. However, baseline adjustment may introduce error if the association between baseline HbA1c and response is substantially due to measurement error and regression to the mean. We aimed to determine whether studies of predictors of response should adjust for baseline HbA1c. Methods We assessed the relationship between baseline HbA1c and glycaemic response in 257 participants treated with GLP-1R agonists and assessed whether it reflected measurement error and regression to the mean using duplicate ‘pre-baseline’ HbA1c measurements not included in the response variable. In this cohort and an additional 2659 participants treated with sulfonylureas we assessed the relationship between covariates associated with baseline HbA1c and treatment response with and without baseline adjustment, and with a bias correction using pre-baseline HbA1c to adjust for the effects of error in baseline HbA1c. Results Baseline HbA1c was a major predictor of response (R2 = 0.19,β = -0.44,pHbA1c were associated with response, however these associations were weak or absent after adjustment for baseline HbA1c. Bias correction did not substantially alter associations. Conclusions Adjustment for the baseline HbA1c measurement is a simple and effective way to reduce bias in studies of predictors of response to glucose lowering therapy. PMID:27050911

  1. Could baseline establishment be counterproductive for emissions reduction? Insights from Vietnam’s building sector

    DEFF Research Database (Denmark)

    Henrysson, Maryna; Lütken, Søren; Puig, Daniel

    2017-01-01

    Mitigation Actions (NAMAs) to illustrate institutional dynamics, nationally and transnationally, as well as to question whether demands for baseline setting achieve the ideal trade-off between actual GHG emissions reduction and institutionalized demands for accountability. The analysis reveals that......, it argues for the abolition of baselines in favour of adequate monitoring and evaluation, from the perspective that requirement for deviation from fictitious baselines is unproductive and only serves an international techno-managerial discourse....

  2. An Automatic Baseline Regulation in a Highly Integrated Receiver Chip for JUNO

    Science.gov (United States)

    Muralidharan, P.; Zambanini, A.; Karagounis, M.; Grewing, C.; Liebau, D.; Nielinger, D.; Robens, M.; Kruth, A.; Peters, C.; Parkalian, N.; Yegin, U.; van Waasen, S.

    2017-09-01

    This paper describes the data processing unit and an automatic baseline regulation of a highly integrated readout chip (Vulcan) for JUNO. The chip collects data continuously at 1 Gsamples/sec. The Primary data processing which is performed in the integrated circuit can aid to reduce the memory and data processing efforts in the subsequent stages. In addition, a baseline regulator compensating a shift in the baseline is described.

  3. Baseline albumin is associated with worsening renal function in patients with acute decompensated heart failure receiving continuous infusion loop diuretics.

    Science.gov (United States)

    Clarke, Megan M; Dorsch, Michael P; Kim, Susie; Aaronson, Keith D; Koelling, Todd M; Bleske, Barry E

    2013-06-01

    To identify baseline predictors of worsening renal function (WRF) in an acute decompensated heart failure (ADHF) patient population receiving continuous infusion loop diuretics. Retrospective observational analysis. Academic tertiary medical center. A total of 177 patients with ADHF receiving continuous infusion loop diuretics from January 2006 through June 2009. The mean patient age was 61 years, 63% were male, ~45% were classified as New York Heart Association functional class III, and the median length of loop diuretic infusion was 4 days. Forty-eight patients (27%) developed WRF, and 34 patients (19%) died during hospitalization. Cox regression time-to-event analysis was used to determine the time to WRF based on different demographic and clinical variables. Baseline serum albumin 3 g/dl or less was the only significant predictor of WRF (hazard ratio [HR] 2.87, 95% confidence interval [CI] 1.60-5.16, p=0.0004), which remained significant despite adjustments for other covariates. Serum albumin 3 g/dl or less is a practical baseline characteristic associated with the development of WRF in patients with ADHF receiving continuous infusion loop diuretics. © 2013 Pharmacotherapy Publications, Inc.

  4. A Kalman filter-based short baseline RTK algorithm for single-frequency combination of GPS and BDS.

    Science.gov (United States)

    Zhao, Sihao; Cui, Xiaowei; Guan, Feng; Lu, Mingquan

    2014-08-20

    The emerging Global Navigation Satellite Systems (GNSS) including the BeiDou Navigation Satellite System (BDS) offer more visible satellites for positioning users. To employ those new satellites in a real-time kinematic (RTK) algorithm to enhance positioning precision and availability, a data processing model for the dual constellation of GPS and BDS is proposed and analyzed. A Kalman filter-based algorithm is developed to estimate the float ambiguities for short baseline scenarios. The entire work process of the high-precision algorithm based on the proposed model is deeply investigated in detail. The model is validated with real GPS and BDS data recorded from one zero and two short baseline experiments. Results show that the proposed algorithm can generate fixed baseline output with the same precision level as that of either a single GPS or BDS RTK algorithm. The significantly improved fixed rate and time to first fix of the proposed method demonstrates a better availability and effectiveness on processing multi-GNSSs.

  5. Parkinson’s Disease Severity at 3 Years Can Be Predicted from Non-Motor Symptoms at Baseline

    Directory of Open Access Journals (Sweden)

    Alba Ayala

    2017-10-01

    Full Text Available ObjectiveThe aim of this study is to present a predictive model of Parkinson’s disease (PD global severity, measured with the Clinical Impression of Severity Index for Parkinson’s Disease (CISI-PD.MethodsThis is an observational, longitudinal study with annual follow-up assessments over 3 years (four time points. A multilevel analysis and multiple imputation techniques were performed to generate a predictive model that estimates changes in the CISI-PD at 1, 2, and 3 years.ResultsThe clinical state of patients (CISI-PD significantly worsened in the 3-year follow-up. However, this change was of small magnitude (effect size: 0.44. The following baseline variables were significant predictors of the global severity change: baseline global severity of disease, levodopa equivalent dose, depression and anxiety symptoms, autonomic dysfunction, and cognitive state. The goodness-of-fit of the model was adequate, and the sensitive analysis showed that the data imputation method applied was suitable.ConclusionDisease progression depends more on the individual’s baseline characteristics than on the 3-year time period. Results may contribute to a better understanding of the evolution of PD including the non-motor manifestations of the disease.

  6. A Kalman Filter-Based Short Baseline RTK Algorithm for Single-Frequency Combination of GPS and BDS

    Directory of Open Access Journals (Sweden)

    Sihao Zhao

    2014-08-01

    Full Text Available The emerging Global Navigation Satellite Systems (GNSS including the BeiDou Navigation Satellite System (BDS offer more visible satellites for positioning users. To employ those new satellites in a real-time kinematic (RTK algorithm to enhance positioning precision and availability, a data processing model for the dual constellation of GPS and BDS is proposed and analyzed. A Kalman filter-based algorithm is developed to estimate the float ambiguities for short baseline scenarios. The entire work process of the high-precision algorithm based on the proposed model is deeply investigated in detail. The model is validated with real GPS and BDS data recorded from one zero and two short baseline experiments. Results show that the proposed algorithm can generate fixed baseline output with the same precision level as that of either a single GPS or BDS RTK algorithm. The significantly improved fixed rate and time to first fix of the proposed method demonstrates a better availability and effectiveness on processing multi-GNSSs.

  7. Baseline Characteristics of Fall from Height Victims Presenting to Emergency Department; a Brief Report

    Directory of Open Access Journals (Sweden)

    Hamidreza Hatamabadi

    2017-01-01

    Full Text Available Introduction: Trauma due to accidents or fall from height is a major cause of disability and mortality. The present study was designed aiming to evaluate the baseline characteristics of fall from height victims presenting to emergency department (ED.Methods: This prospective cross-sectional study evaluates the baseline characteristics of fall from height cases presenting to EDs of three educational Hospitals, Tehran, Iran, during one year. Data were analyzed using SPSS 21 and presented using descriptive statistics.Results: 460 patients with the mean age of 27.89 ± 20.95 years were evaluated (76.5% male. 191 (41.5% falls occurred when working, 27 (5.9% during play, and 242 (52.6% in other times. Among construction workers, 166 (81.4% had not used any safety equipment. Fracture and dislocation with 180 (39.1% cases and soft tissue injury with 166 (36.1% were the most common injuries inflicted. Mean height of falling was 3.41 ± 0.34 (range: 0.5 – 20 meters. Finally, 8 (1.7% of the patients died (50% intentional and 63% were discharged from ED. A significant correlation was detected between mortality and the falls being intentional (p < 0.0001 as well as greater height of fall (p < 0.0001.Conclusion: Based on the findings, most fall from height victims in the present study were young men, single, construction workers, with less than high school diploma education level. Intentional fall and greater height of falling significantly correlated with mortality.

  8. Is Baseline Cardiac Autonomic Modulation Related to Performance and Physiological Responses Following a Supramaximal Judo Test?

    Science.gov (United States)

    Blasco-Lafarga, Cristina; Martínez-Navarro, Ignacio; Mateo-March, Manuel

    2013-01-01

    Little research exists concerning Heart Rate (HR) Variability (HRV) following supramaximal efforts focused on upper-body explosive strength-endurance. Since they may be very demanding, it seems of interest to analyse the relationship among performance, lactate and HR dynamics (i.e. HR, HRV and complexity) following them; as well as to know how baseline cardiac autonomic modulation mediates these relationships. The present study aimed to analyse associations between baseline and post-exercise HR dynamics following a supramaximal Judo test, and their relationship with lactate, in a sample of 22 highly-trained male judoists (20.70±4.56 years). A large association between the increase in HR from resting to exercise condition and performance suggests that individuals exerted a greater sympathetic response to achieve a better performance (Rating of Perceived Exertion: 20; post-exercise peak lactate: 11.57±2.24 mmol/L; 95.76±4.13 % of age-predicted HRmax). Athletes with higher vagal modulation and lower sympathetic modulation at rest achieved both a significant larger ∆HR and a faster post-exercise lactate removal. A enhanced resting parasympathetic modulation might be therefore related to a further usage of autonomic resources and a better immediate metabolic recovery during supramaximal exertions. Furthermore, analyses of variance displayed a persistent increase in α1 and a decrease in lnRMSSD along the 15 min of recovery, which are indicative of a diminished vagal modulation together with a sympathovagal balance leaning to sympathetic domination. Eventually, time-domain indices (lnRMSSD) showed no lactate correlations, while nonlinear indices (α1 and lnSaEn) appeared to be moderate to strongly correlated with it, thus pointing to shared mechanisms between neuroautonomic and metabolic regulation. PMID:24205273

  9. Gender Differences in Symptom Reporting on Baseline Sport Concussion Testing Across the Youth Age Span.

    Science.gov (United States)

    Moser, Rosemarie Scolaro; Olek, Lauren; Schatz, Philip

    2018-02-06

    Little is known regarding gender differences in concussion symptom reporting developmentally across the age span, specifically in pre-adolescent athletes. The present study asks: Do boys and girls differ in symptom reporting across the pre-adolescent to post-adolescent age span? This retrospective study utilized baseline assessments from 11,695 10-22 year-old athletes assigned to 3 independent groups: Pre-adolescent 10-12 year olds (n = 1,367; 12%), Adolescent 13-17 year olds (n = 2,974; 25%), and Late Adolescent 18-22 year olds (n = 7,354; 63%). Males represented 60% of the sample. Baseline ImPACT composite scores and Post-Concussion Symptom Scale scores (Total, Physical, Cognitive, Emotional, Sleep) were analyzed for the effects of age and gender. Statistically significant main effects were found for age and gender on all ImPACT composites, Total Symptoms, and Symptom factors. Significant interaction effects were noted between age and gender for all ImPACT composites, Total Symptoms, and Symptom factors. Total Symptoms and all Symptom factors were highest in adolescents (ages 13-17) for males and females. In the 10-12 age group, females displayed lower Total Symptoms, Physical, and Sleep factors than males. The notion of females being more likely than males to report symptoms does not appear to apply across the developmental age span, particularly prior to adolescence. Females show greater emotional endorsement across the youth age span (10-22 years). Adolescence (13-17 years) appears to be a time of increased symptomatology that may lessen after the age of 18. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Baseline reef health surveys at Bangka Island (North Sulawesi, Indonesia reveal new threats

    Directory of Open Access Journals (Sweden)

    Massimo Ponti

    2016-10-01

    Full Text Available Worldwide coral reef decline appears to be accompanied by an increase in the spread of hard coral diseases. However, whether this is the result of increased direct and indirect human disturbances and/or an increase in natural stresses remains poorly understood. The provision of baseline surveys for monitoring coral health status lays the foundations to assess the effects of any such anthropogenic and/or natural effects on reefs. Therefore, the objectives of this present study were to provide a coral health baseline in a poorly studied area, and to investigate possible correlations between coral health and the level of anthropogenic and natural disturbances. During the survey period, we recorded 20 different types of coral diseases and other compromised health statuses. The most abundant were cases of coral bleaching, followed by skeletal deformations caused by pyrgomatid barnacles, damage caused by fish bites, general pigmentation response and galls caused by cryptochirid crabs. Instances of colonies affected by skeletal eroding bands, and sedimentation damage increased in correlation to the level of bio-chemical disturbance and/or proximity to villages. Moreover, galls caused by cryptochirid crabs appeared more abundant at sites affected by blast fishing and close to a newly opened metal mine. Interestingly, in the investigated area the percentage of corals showing signs of ‘common’ diseases such as black band disease, brown band disease, white syndrome and skeletal eroding band disease were relatively low. Nevertheless, the relatively high occurrence of less common signs of compromised coral-related reef health, including the aggressive overgrowth by sponges, deserves further investigation. Although diseases appear relatively low at the current time, this area may be at the tipping point and an increase in activities such as mining may irredeemably compromise reef health.

  11. Baseline Lower Urinary Tract Symptoms in Patients Enrolled in LURN: A Prospective, Observational Cohort Study.

    Science.gov (United States)

    Cameron, Anne P; Lewicky-Gaupp, Christina; Smith, Abigail R; Helfand, Brian T; Gore, John L; Clemens, J Quentin; Yang, Claire C; Siddiqui, Nazema Y; Lai, H Henry; Griffith, James W; Andreev, Victor P; Liu, Gang; Weinfurt, Kevin; Amundsen, Cindy L; Bradley, Catherine S; Kusek, John W; Kirkali, Ziya

    2018-04-01

    We described and compared the frequency and type of lower urinary tract symptoms reported by men and women at the time that they were recruited from urology and urogynecology clinics into the Symptoms of Lower Urinary Tract Dysfunction Research Network multicenter, prospective, observational cohort study. At 6 research sites treatment seeking men and women were enrolled who reported any lower urinary tract symptoms at a frequency more than rarely during the last month on the LUTS (Lower Urinary Tract Symptoms) Tool. At baseline the study participants underwent a standardized clinical evaluation and completed validated questionnaires. Urological tests were performed, including pelvic/rectal examination, post-void residual urine measurement and urinalysis. A total of 545 women and 519 men were enrolled in the study. Mean ± SD age was 58.8 ± 14.1 years. At baseline nocturia, frequency and a sensation of incomplete emptying were similar in men and women but men experienced more voiding symptoms (90% vs 85%, p = 0.007) and women reported more urgency (85% vs 66%, p urinary incontinence than men (82% vs 51% p urinary incontinence, including post-void dribbling in 44% and urgency incontinence in 46%. Older participants had higher odds of reporting symptoms of nocturia and urgency. In this large, treatment seeking cohort of men and women lower urinary tract symptoms varied widely by gender and age. Men reported more voiding symptoms and nonstress or urgency urinary incontinence while women reported more incontinence overall and urgency. Older participants had greater odds of urgency and nocturia. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. A Prospective Study of Pravastatin in the Elderly at Risk (PROSPER): Screening Experience and Baseline Characteristics.

    LENUS (Irish Health Repository)

    Ford, Ian

    2002-05-20

    BACKGROUND: PROSPER was designed to investigate the benefits of treatment with pravastatin in elderly patients for whom a typical doctor might consider the prescription of statin therapy to be a realistic option. METHODS: The PROspective Study of Pravastatin in the Elderly at Risk (PROSPER) is a randomised, double blind, placebo-controlled trial to test the hypothesis that treatment with pravastatin (40 mg\\/day) will reduce the risk of coronary heart disease death, non-fatal myocardial infarction, and fatal or non-fatal stroke in elderly men and women with pre-existing vascular disease or with significant risk of developing this condition. RESULTS: In Scotland, Ireland, and the Netherlands, 23,770 individuals were screened, and 5,804 subjects (2,804 men and 3,000 women), aged 70 to 82 years (average 75 years) and with baseline cholesterol 4.0-9.0 mmol\\/l, were randomised. Randomised subjects had similar distributions with respect to age, blood pressure, and body mass index when compared to the entire group of screenees, but had a higher prevalence of smoking, diabetes, hypertension, and a history of vascular disease. The average total cholesterol level at baseline was 5.4 mmol\\/l (men) and 6.0 mmol\\/l (women). CONCLUSIONS: Compared with previous prevention trials of cholesterol-lowering drugs, the PROSPER cohort is significantly older and for the first time includes a majority of women. The study, having achieved its initial goal of recruiting more than 5,500 elderly high-risk men and women, aims to complete all final subject follow-up visits in the first half of 2002 with the main results being available in the fourth quarter of 2002.

  13. A Prospective Study of Pravastatin in the Elderly at Risk (PROSPER): Screening Experience and Baseline Characteristics

    Science.gov (United States)

    Ford, Ian; Blauw, Gerard Jan; Murphy, Michael B; Shepherd, James; Cobbe, Stuart M; Bollen, Edward LEM; Buckley, Brendan M; Jukema, J Wouter; Hyland, Michael; Gaw, Allan; Lagaay, A Margot; Perry, Ivan J; Macfarlane, Peter; Norrie, John; Meinders, A Edo; Sweeney, Brian J; Packard, Chris J; Westendorp, Rudi GJ; Twomey, Cillian; Stott, David J

    2002-01-01

    Background PROSPER was designed to investigate the benefits of treatment with pravastatin in elderly patients for whom a typical doctor might consider the prescription of statin therapy to be a realistic option. Methods The PROspective Study of Pravastatin in the Elderly at Risk (PROSPER) is a randomised, double blind, placebo-controlled trial to test the hypothesis that treatment with pravastatin (40 mg/day) will reduce the risk of coronary heart disease death, non-fatal myocardial infarction, and fatal or non-fatal stroke in elderly men and women with pre-existing vascular disease or with significant risk of developing this condition. Results In Scotland, Ireland, and the Netherlands, 23,770 individuals were screened, and 5,804 subjects (2,804 men and 3,000 women), aged 70 to 82 years (average 75 years) and with baseline cholesterol 4.0–9.0 mmol/l, were randomised. Randomised subjects had similar distributions with respect to age, blood pressure, and body mass index when compared to the entire group of screenees, but had a higher prevalence of smoking, diabetes, hypertension, and a history of vascular disease. The average total cholesterol level at baseline was 5.4 mmol/l (men) and 6.0 mmol/l (women). Conclusions Compared with previous prevention trials of cholesterol-lowering drugs, the PROSPER cohort is significantly older and for the first time includes a majority of women. The study, having achieved its initial goal of recruiting more than 5,500 elderly high-risk men and women, aims to complete all final subject follow-up visits in the first half of 2002 with the main results being available in the fourth quarter of 2002. PMID:12097148

  14. A Prospective Study of Pravastatin in the Elderly at Risk (PROSPER: Screening Experience and Baseline Characteristics

    Directory of Open Access Journals (Sweden)

    Lagaay A Margot

    2002-05-01

    Full Text Available Abstract Background PROSPER was designed to investigate the benefits of treatment with pravastatin in elderly patients for whom a typical doctor might consider the prescription of statin therapy to be a realistic option. Methods The PROspective Study of Pravastatin in the Elderly at Risk (PROSPER is a randomised, double blind, placebo-controlled trial to test the hypothesis that treatment with pravastatin (40 mg/day will reduce the risk of coronary heart disease death, non-fatal myocardial infarction, and fatal or non-fatal stroke in elderly men and women with pre-existing vascular disease or with significant risk of developing this condition. Results In Scotland, Ireland, and the Netherlands, 23,770 individuals were screened, and 5,804 subjects (2,804 men and 3,000 women, aged 70 to 82 years (average 75 years and with baseline cholesterol 4.0–9.0 mmol/l, were randomised. Randomised subjects had similar distributions with respect to age, blood pressure, and body mass index when compared to the entire group of screenees, but had a higher prevalence of smoking, diabetes, hypertension, and a history of vascular disease. The average total cholesterol level at baseline was 5.4 mmol/l (men and 6.0 mmol/l (women. Conclusions Compared with previous prevention trials of cholesterol-lowering drugs, the PROSPER cohort is significantly older and for the first time includes a majority of women. The study, having achieved its initial goal of recruiting more than 5,500 elderly high-risk men and women, aims to complete all final subject follow-up visits in the first half of 2002 with the main results being available in the fourth quarter of 2002.

  15. Local Biomass Baselines and the Recovery Potential for Hawaiian Coral Reef Fish Communities

    Directory of Open Access Journals (Sweden)

    Kelvin D. Gorospe

    2018-05-01

    Full Text Available Understanding the influence of multiple ecosystem drivers, both natural and anthropogenic, and how they vary across space is critical to the spatial management of coral reef fisheries. In Hawaii, as elsewhere, there is uncertainty with regards to how areas should be selected for protection, and management efforts prioritized. One strategy is to prioritize efforts based on an area's biomass baseline, or natural capacity to support reef fish populations. Another strategy is to prioritize areas based on their recovery potential, or in other words, the potential increase in fish biomass from present-day state, should management be effective at restoring assemblages to something more like their baseline state. We used data from 717 fisheries-independent reef fish monitoring surveys from 2012 to 2015 around the main Hawaiian Islands as well as site-level data on benthic habitat, oceanographic conditions, and human population density, to develop a hierarchical, linear Bayesian model that explains spatial variation in: (1 herbivorous and (2 total reef fish biomass. We found that while human population density negatively affected fish assemblages at all surveyed areas, there was considerable variation in the natural capacity of different areas to support reef fish biomass. For example, some areas were predicted to have the capacity to support ten times as much herbivorous fish biomass as other areas. Overall, the model found human population density to have negatively impacted fish biomass throughout Hawaii, however the magnitude and uncertainty of these impacts varied locally. Results provide part of the basis for marine spatial planning and/or MPA-network design within Hawaii.

  16. A Baseline Air Quality Assessment Onboard a Victoria Class Submarine: HMCS Windsor

    National Research Council Canada - National Science Library

    Severs, Y. D

    2006-01-01

    .... This trial thus represents a baseline habitability evaluation of Canada's Victoria class submarines to confirm compliance with the current maximum permissible contaminant limits stipulated in the Air...

  17. Baseline characteristics in PRIORITY study: Proteomics and mineralocorticoid receptor antagonism for prevention of diabetic nephropathy in type 2 diabetes

    DEFF Research Database (Denmark)

    Tofte, Nete

    diabetic nephRopathy In TYpe 2 diabetic patients with normoalbuminuria) trial, the aim is to confirm that CKD273 can predict microalbuminuria prospectively, and to test whether mineralocorticoid receptor antagonism (MRA) delays progression to microalbuminuria. Here we report the association between CKD273...... and traditional risk factors for diabetic nephropathy at baseline. Materials and methods PRIORITY is an investigator-initiated, prospective, randomized, double blind, placebo-controlled multicentre clinical trial and observational study in normoalbuminuric type 2 diabetic patients. Patients are stratified...... is development of microalbuminuria. Results In total 2277 type 2 diabetic patients have been screened over a time period of 2.5 years and 1811 are included from 15 sites. Table 1 shows the baseline characteristics. 224 (12.4%) have the high-risk CKD273 pattern. The high- and low-risk populations differ...

  18. Baseline and projected future carbon storage and greenhouse-gas fluxes in the Great Plains region of the United States

    Science.gov (United States)

    Bouchard, Michelle; Butman, David; Hawbaker, Todd; Li, Zhengpeng; Liu, Jinxun; Liu, Shu-Guang; McDonald, Cory; Reker, Ryan R.; Sayler, Kristi; Sleeter, Benjamin; Sohl, Terry; Stackpoole, Sarah; Wein, Anne; Zhu, Zhi-Liang; Zhu, Zhi-Liang

    2011-01-01

    This assessment was conducted to fulfill the requirements of section 712 of the Energy Independence and Security Act (EISA) of 2007 and to improve understanding of carbon and greenhouse gas (GHG) fluxes in the Great Plains region in the central part of the United States. The assessment examined carbon storage, carbon fluxes, and other GHG fluxes (methane and nitrous oxide) in all major terrestrial ecosystems (forests, grasslands/shrublands, agricultural lands, and wetlands) and freshwater aquatic systems (rivers, streams, lakes, and impoundments) in two time periods: baseline (generally in the first half of the 2010s) and future (projections from baseline to 2050). The assessment was based on measured and observed data collected by the U.S. Geological Survey (USGS) and many other agencies and organizations and used remote sensing, statistical methods, and simulation models.

  19. Phytoplankton and the Macondo oil spill: A comparison of the 2010 phytoplankton assemblage to baseline conditions on the Louisiana shelf.

    Science.gov (United States)

    Parsons, M L; Morrison, W; Rabalais, N N; Turner, R E; Tyre, K N

    2015-12-01

    The Macondo oil spill was likely the largest oil spill to ever occur in United States territorial waters. We report herein our findings comparing the available baseline phytoplankton data from coastal waters west of the Mississippi River, and samples collected monthly from the same sampling stations, during and after the oil spill (May-October, 2010). Our results indicate that overall, the phytoplankton abundance was 85% lower in 2010 versus the baseline, and that the species composition of the phytoplankton community moved towards diatoms and cyanobacteria and away from ciliates and phytoflagellates. The results of this study reaffirm the view that phytoplankton responses will vary by the seasonal timing of the oil spill and the specific composition of the spilled oil. The trophic impacts of the purported lower abundance of phytoplankton in 2010 coupled with the observed assemblage shift remain unknown. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Lawrence Livermore National Laboratory Emergency Response Capability Baseline Needs Assessment Requirement Document

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2009-12-30

    This revision of the LLNL Fire Protection Baseline Needs Assessment (BNA) was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by Martin Gresho, Sandia/CA Fire Marshal. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only address emergency response. The original LLNL BNA was created on April 23, 1997 as a means of collecting all requirements concerning emergency response capabilities at LLNL (including response to emergencies at Sandia/CA) into one BNA document. The original BNA documented the basis for emergency response, emergency personnel staffing, and emergency response equipment over the years. The BNA has been updated and reissued five times since in 1998, 1999, 2000, 2002, and 2004. A significant format change was performed in the 2004 update of the BNA in that it was 'zero based.' Starting with the requirement documents, the 2004 BNA evaluated the requirements, and determined minimum needs without regard to previous evaluations. This 2010 update maintains the same basic format and requirements as the 2004 BNA. In this 2010 BNA, as in the previous BNA, the document has been intentionally divided into two separate documents - the needs assessment (1) and the compliance assessment (2). The needs assessment will be referred to as the BNA and the compliance assessment will be referred to as the BNA Compliance Assessment. The primary driver for separation is that the needs assessment identifies the detailed applicable regulations (primarily NFPA Standards) for emergency response capabilities based on the hazards present at LLNL and Sandia/CA and the geographical location of the facilities. The needs assessment also identifies areas where the modification of the requirements in the applicable NFPA standards is appropriate, due to the improved fire protection