WorldWideScience

Sample records for time-resolved esr study

  1. Time-resolved ESR spectroscopy

    International Nuclear Information System (INIS)

    Beckert, D.

    1986-06-01

    The time-resolved ESR spectroscopy is one of the modern methods in radiospectroscopy and plays an important role in solving various problems in chemistry and biology. Proceeding from the basic ideas of time-resolved ESR spectroscopy the experimental equipment is described generally including the equipment developed at the Central Institute of Isotope and Radiation Research. The experimental methods applied to the investigation of effects of chemically induced magnetic polarization of electrons and to kinetic studies of free radicals in polymer systems are presented. The theory of radical pair mechanism is discussed and theoretical expressions are summarized in a computer code to compute the theoretical polarization for each pair of the radicals

  2. ESR spectrometer with a loop-gap resonator for cw and time resolved studies in a superconducting magnet.

    Science.gov (United States)

    Simon, Ferenc; Murányi, Ferenc

    2005-04-01

    The design and performance of an electron spin resonance spectrometer operating at 3 and 9 GHz microwave frequencies combined with a 9-T superconducting magnet are described. The probehead contains a compact two-loop, one gap resonator, and is inside the variable temperature insert of the magnet enabling measurements in the 0-9T magnetic field and 1.5-400 K temperature range. The spectrometer allows studies on systems where resonance occurs at fields far above the g approximately 2 paramagnetic condition such as in antiferromagnets. The low quality factor of the resonator allows time resolved experiments such as, e.g., longitudinally detected ESR. We demonstrate the performance of the spectrometer on the NaNiO2 antiferromagnet, the MgB2 superconductor, and the RbC60 conducting alkaline fulleride polymer.

  3. Mass measurement of cooled neutron-deficient bismuth projectile fragments with time-resolved Schottky mass spectrometry at the FRS-ESR facility

    Energy Technology Data Exchange (ETDEWEB)

    Litvinov, Yu.A.; Geissel, H. [Giessen Univ. (Germany); Radon, T. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (DE)] [and others

    2005-06-01

    Masses of 582 neutron-deficient nuclides (30{<=}Z{<=}85) were measured with time-resolved Schottky mass spectrometry at the FRS-ESR facility at GSI, 117 were used for calibration. The masses of 71 nuclides were obtained for the first time. A typical mass accuracy of 30 {mu}u was achieved. These data have entered the latest atomic mass evaluation. The mass determination of about 140 additional nuclides was possible via known energies (Q-values) of {alpha}-, {beta}-, or proton decays. The obtained results are compared with the results of other measurements. (orig.)

  4. Studies of the reactions of hydrogen atoms by time-resolved E. S. R. spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fessenden, R W; Verma, N C [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA). Dept. of Chemistry

    1977-01-01

    Time-resolved e.s.r. spectroscopy has been used to follow directly the reactions of H atoms produced by pulse radiolysis of acid solutions. Detailed analysis of the time profile of the e.s.r. signal was carried out by means of modified Bloch equations. The increased signal found when a scavenger for OH such as t-butyl alcohol is present is shown to be mainly the result of slower H atom decay by radical-radical reaction. The reaction H + OH does not appear to produce any signal polarization. The decay curves observed in the presence of solute are readily accounted for by the treatment, and good plots of pseudo first-order rate constant against solute concentration are obtained. The absolute rate constants for reaction with H atoms are for methanol 2.5 x10/sup 6/, for ethanol 2.1 X 10/sup 7/, for isopropanol 6.8 x 10/sup 7/, and for succinic acid 3.0 x 10/sup 6/ dm/sup 3/ mol/sup -1/s/sup -1/. These values are in good agreement with the earlier chemical measurements.

  5. Study on detection of electron beam irradiated food by ESR spectroscopy and comparison of the ESR spectrum of electron beams and γ-rays

    International Nuclear Information System (INIS)

    Li Weiming; Ha Yiming; Wang Feng

    2012-01-01

    The study was conducted to detect electron beam irradiated food by ESR spectroscopy. The white pepper powder, paprika powder, cumin powder and pistachios were used as test materials to study the feature changes of ESR spectrum and the relationship between ESR intensity and irradiation dose in different doses, the shape variation of ESR spectrum in γ-rays and electron beams in the same sample was also compared. The results showed that the ESR spectrum of 4 kinds of irradiated samples was obviously different before and after irradiation, the intensity of ESR signal increased with the increasing of the absorbed dose. The dose above 432 Gy could be detected in white pepper powder and pistachios, the dose above 875 Gy could be detected in paprika powder and cumin powder. The ESR intensity of all samples decreased during the storage time (200 d), even after 200 days the ESR method could also be used to detect whether or not the samples have been irradiated. The same dosage of y-rays and electron beams has no significant influence on the shape of ESR spectrum, however, the difference of irradiation mechanism caused slight impact on ESR intensity. The results could provide the technical basis for the application of ESR method in detecting electron beam irradiated food. (authors)

  6. Study on detection of electron beam irradiated food by ESR spectroscopy and comparison of the ESR spectrum of electron beams and γ-rays

    International Nuclear Information System (INIS)

    Li Weiming; Ha Yiming; Wang Feng

    2011-01-01

    The study was conducted to detect electron beam irradiated food by ESR spectroscopy. The white pepper powder, paprika powder, cumin powder and pistachios were used as test materials to study the feature changes of ESR spectrum and the relationship between ESR intensity and irradiation dose in different doses, the shape variation of ESR spectrum in γ-rays and electron beams in the same sample was also compared. The results showed that the ESR spectrum of 4 kinds of irradiated samples was obviously different before and after irradiation, the intensity of ESR signal increased with the increasing of the absorbed dose. The dose above 432 Gy could be detected in white pepper powder and pistachios, the dose above 875 Gy could be detected in paprika powder and cumin powder. The ESR intensity of all samples decreased during the storage time (200 d), even after 200 days the ESR method could also be used to detect whether or not the samples have been irradiated. The same dosage of γ-rays and electron beams has no significant influence on the shape of ESR spectrum, however, the difference of irradiation mechanism caused slight impact on ESR intensity. The results could provide the technical basis for the application of ESR method in detecting electron beam irradiated food. (authors)

  7. Time-resolved studies. Ch. 9

    International Nuclear Information System (INIS)

    Mills, Dennis M.; Argonne National Lab., IL

    1991-01-01

    Synchrotron radiation, with its unique properties, offers a tool to extend X-ray measurements from the static to the time-resolved regime. The most straight-forward application of synchrotron radiation to the study of transient phenomena is directly through the possibility of decreased data-collection times via the enormous increase in flux over that of a laboratory X-ray system. Even further increases in intensity can be obtained through the use of novel X-ray optical devices. Wide-bandpass monochromators, e.g., that utilize the continuous spectral distribution of synchrotron radiation, can increase flux on the sample several orders of magnitude over conventional X-ray optical systems thereby allowing a further shortening of the data-collection time. Another approach that uses the continuous spectral nature of synchrotron radiation to decrease data-collection times is the 'parallel data collection' method. Using this technique, intensities as a function of X-ray energy are recorded simultaneously for all energies rather than sequentially recording data at each energy, allowing for a dramatic decrease in data-collection time. Perhaps the most exciting advances in time-resolved X-ray studies will be made by those methods that exploit the pulsed nature of the radiation emitted from storage rings. Pulsed techniques have had an enormous impact in the study of the temporal evolution of transient phenomena. The extension from continuous to modulated sources for use in time-resolved work has been carried over in a host of fields that use both pulsed particle and pulsed electro-magnetic beams. In this chapter the new experimental techniques are reviewed and illustrated with some experiments. (author). 98 refs.; 20 figs.; 5 tabs

  8. ESR and TL age determination of caliche nodules

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, A.M. (Middle East Technical Univ., Ankara (Turkey)); Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F. (Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz); Erol, O. (Istanbul Univ. (Turkey). School of Geography and Marine Sciences)

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author).

  9. ESR and TL age determination of caliche nodules

    International Nuclear Information System (INIS)

    Oezer, A.M.; Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F.; Erol, O.

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author)

  10. An x-ray detector for time-resolved studies

    International Nuclear Information System (INIS)

    Rodricks, B.; Brizard, C.; Clarke, R.; Lowe, W.

    1992-01-01

    The development of ultrahigh-brightness x-ray sources makes time-resolved x-ray studies more and more feasible. Improvements in x-ray optics components are also critical for obtaining the appropriate beam for a particular type of experiment. Moreover, fast parallel detectors will be essential in order to exploit the combination of high intensity x-ray sources and novel optics for time-resolved experiments. A CCD detector with a time resolution of microseconds has been developed at the Advanced Photon Source (APS). This detector is fully programmable using CAMAC electronics and a Micro Vax computer. The techniques of time-resolved x-ray studies, which include scattering, microradiography, microtomography, stroboscopy, etc., can be applied to a range of phenomena (including rapid thermal annealing, surface ordering, crystallization, and the kinetics of phase transition) in order to understand these time-dependent microscopic processes. Some of these applications will be illustrated by recent results performed at synchrotrons. New powerful x-ray sources now under construction offer the opportunity to apply innovative approaches in time-resolved work

  11. Estimate of landslide deformation and failure time by ESR technique of. alpha. -quartz

    Energy Technology Data Exchange (ETDEWEB)

    Xingzhong, Liang; Mingdong, Chen [Chengdu Coll. of Geology, SC (China); Jiyong, Chen; Jiamin, Feng [Sichuan Univ., Chengdu, SC (China)

    1991-02-01

    ESR dating has been applied to study landslides. A method of dose-difference to determine the landslide age has been developed. The ESR spectra of annealled quartz grain samples and the optimum conditions of thermal activation were studied. The signifcance of ESR dating of landslide in geological research was discussed.

  12. HPLC-ESR techniques for detection of complex trapped radicals

    International Nuclear Information System (INIS)

    Tu Tiecheng; Dong Jirong; Lin Nianyun; Xie Leidong; Liu Rengzhong

    1992-01-01

    High performance liquid chromatography (HPLC) and ESR combined examination of radical species is an advanced techniques for separation and identification of complex radical species. At SRCL, Waters 990 HPLC has been used to separate the complex trapped radicals and Varian E-112 ESR spectrometer to record the spectra of single trapped radicals after HPLC separation. The advantages of the combined techniques are described as bellow: HPLC is used to separate the long-lived complex trapped radicals derived from reaction of short-lived radicals with spin trap. ESR spectra from single trapped radicals, obtained following HPLC separation of complex trapped radicals, are recorded one by one and well resolved. The structures of short-lived radicals can be inferred from the ESR spectra of the long-lived trapped radicals

  13. Basic ESR studies on recent corals

    Science.gov (United States)

    Walther, Ralf; Barabas, Michael; Mangini, Augusto

    Experiments on recent corals ( Acropora palmata, Barbados) were carried out to study the dating relevant properties of the characteristic ESR signals. Highly resolved signal growth curves (55 aliquots of a sieve fraction 125-250 μm) were obtained by γ-irradiation in small steps up to 20 kGy. The signal growth curve of the 'dating signal' at g = 2.0006 can only be approximated by a single exponential saturation function in a certain dose range. Thus, ADs derived with this function tend to be overestimated. A better analytical description by two different functions was tested. Isothermal annealing experiments were carried out at various temperatures before and after irradiation with a definite γ-dose respectively. The thermal decay of the dating signal is not 1st order. Furthermore, the decay process is strongly influenced by the decay of the traps themselves. The behaviour of the signals at g = 2.0057 and g = 2.0031 was compared with that of the dating signal. A surprising result was the growth of the signal at g = 2.0057 with γ-irradiation.

  14. Time-resolved studies

    International Nuclear Information System (INIS)

    Mills, D.M.

    1992-01-01

    When new or more powerful probes become available that offer both shorter data-collection times and the opportunity to apply innovative approaches to established techniques, it is natural that investigators consider the feasibility of exploring the kinetics of time-evolving systems. This stimulating area of research not only can lead to insights into the metastable or excited states that a system may populate on its way to a ground state, but can also lead to a better understanding of that final state. Synchrotron radiation, with its unique properties, offers just such a tool to extend X-ray measurements from the static to the time-resolved regime. The most straight-forward application of synchrotron radiation to the study of transient phenomena is directly through the possibility of decreased data-collection times via the enormous increase in flux over that of a laboratory X-ray system. Even further increases in intensity can be obtained through the use of novel X-ray optical devices. Widebandpass monochromators, e.g., that utilize the continuous spectral distribution of synchrotron radiation, can increase flux on the sample several orders of magnitude over conventional X-ray optical systems thereby allowing a further shortening of the data-collection time. Another approach that uses the continuous spectral nature of synchrotron radiation to decrease data-collection times is the open-quote parallel data collectionclose quotes method. Using this technique, intensities as a function of X-ray energy are recorded simultaneously for all energies rather than sequentially recording data at each energy, allowing for a dramatic decrease in the data-collection time

  15. ESR and TL studies of irradiated Anatolian laurel leaf (Laurus nobilis L.)

    Science.gov (United States)

    Tepe Çam, Semra; Aydaş, Canan; Engin, Birol; Rabia Yüce, Ülkü; Aydın, Talat; Polat, Mustafa

    2012-06-01

    Laurel leaf (Laurus nobilis L.) samples that originated from Turkey were analyzed by electron spin resonance (ESR) and thermoluminescence (TL) techniques before and after γ-irradiation. Unirradiated (control) laurel leaf samples exhibit a weak ESR singlet centered at g=2.0020. Besides this central signal were two weak satellite signals situated about 3 mT left and right to it in radiation-induced spectra. The dose-response curve of the radiation-induced ESR signal at g=2.0187 (the left satellite signal) was found to be described well by a power function. Variation of the left satellite ESR signal intensity of irradiated samples at room temperature with time in a long term showed that cellulosic free radicals responsible for the ESR spectrum of laurel leaves were not stable but detectable even after 100 days. Annealing studies at four different temperatures were used to determine the kinetic behavior and activation energy of the radiation-induced cellulosic free radicals responsible from the left satellite signal (g=2.0187) in laurel leaves. TL measurements of the polymineral dust isolated from the laurel leaf samples allowed distinguishing between irradiated and unirradiated samples.

  16. Comparative Study of Erythrocyte Sedimentation Rate (ESR) Using ...

    African Journals Online (AJOL)

    MICHAEL

    significant difference between the ESR values obtained using trisodium citrate and whole blood (P< 0.05). Males had lower ESR ... The ESR is governed by the balance between pro- ... 1999). When an inflammatory process is present, the.

  17. Study on identification of irradiated food containing cellulose by ESR

    International Nuclear Information System (INIS)

    Wan Xiaojuan; Dou Daying; Xu Gang; Jiao Zheng; Wang Jia; Zheng Jianfei; Jiao Zheng; Wu Minghong; Ding Guoji

    2008-01-01

    The fast development and application of food irradiation technology signify the necessity and urgency to research on effective detection method for irradiated food. In this paper, we report a preliminary study in this area with dried chili powder, peanuts and strawberry seeds. The food samples were irradiated to 0.5, 1.0, 3.0, 5.0 and 10.0 kGy by 60 Co gamma rays. The relation between ESR intensity and irradiation dose, and correlation R 2 , were studied. The results showed that the ESR signal intensity is positively related with the dose. ESR intensity of the strawberry increased the slowest with the dose, and the chili powder had the most accurate calculation. Accurate dose-effect curves, however, require repeating tests and further studies are needed to verify the ESR results. (authors)

  18. Identification of irradiated mangoes by means of ESR spectroscopy

    International Nuclear Information System (INIS)

    Bustos, M.E.; Romero, M.E.; Gutierrez, A.; Azorin, J.

    1996-01-01

    Samples of mango varieties Tommy Atkins, Haiden and Ataulfo were irradiated with 60 Co gamma radiation at doses in the range 0.15-1.0 kGy, and stored at room temperature for lapses of time up to 72 h. They were then studied by ESR spectrometry. Results show that the ESR signal of the irradiated samples is higher than that of the unirradiated samples, and this is found even at the minimum radiation dose of 0.15 kGy. The ESR signal remained stable during the storage time. The ESR signals obtained for hydroheated mangoes show insignificant differences with respect to the control samples. (author)

  19. ESR studies on CaCO3 of deep-sea sediments

    International Nuclear Information System (INIS)

    Mangini, A.; Segl, M.; Schmitz, W.

    1983-01-01

    We have measured depth profiles of the ESR signals on the calcite fraction in 3 deep-sea sediments with a well-established age stratigraphy and CaCO 3 contents around 50 percent. In the ESR spectra of the foraminifera we observe 3 lines (A, B and C, following Ikeya's notation) two of which (A and C) were analysed as depth profiles. The A signal displays a continuous increase with depth over the time periods covered by the sediment cores of 400,000 and 800,000 a B.P. This suggests that a) the lifetime of the electron traps is long compared to these time intervals and b) the traps as yet unsaturated with electrons. Despite our present ignorance of the nature of the traps, these results might indicate the possible future applicability of ESR as a tool for dating sediment cores over time periods up to 1 Ma. The more prominent C signal displays a linear increase over time periods of 100,000 to 200,000 a. Beyond this age we find an overall increase, on which is superimposed short-term noise of similar amplitude that is unrelated to the 232 Th and CaCO 3 contents. (author)

  20. Lactose and ''tris'' lyoluminescence dosimetry systems and ESR correlation studies

    International Nuclear Information System (INIS)

    Oommen, I.K.; Nambi, K.S.V.; Sengupta, S.; Rao, T.K.G.; Ravikumar, M.

    1989-01-01

    Lyoluminescence (LL) dosimeters have been developed using lactose monohydrate (disaccharide) and tris(hydroxymethyl)aminomethane (''Tris'') systems and attempts have been made to understand the LL mechanism through ESR correlation studies. Tris LL dosimeter has a γ-ray sensitivity with a linear response in the absorbed-dose range 0.05-200 Gy (5-2 x 10 4 rad), while the lactose response extends to a higher range from 1 to 10 4 Gy (10 2 -10 6 rad). The LL output of lactose and Tris did not show any appreciable decay for a period of 6 months after irradiation. ESR measurements show that free-radical concentration in both the systems increases with γ-ray dose in the range 10 2 -10 5 Gy. The minimum dose required to measure the radiation-induced ESR signal for Tris is ∼ 500 Gy, the dose at which the LL output saturates, while lactose shows a radiation-induced ESR signal right at the minimum dose where LL could be detected. The estimated spin density on the radical carbon atom is 0.7. ESR signal stabilities of lactose and Tris were also studied. Lactose did not show any appreciable ESR decay for a period of 3 months after irradiation, while, for Tris, one of the radicals showed a decay of 45% for the same period. (author)

  1. Time resolved techniques: An overview

    International Nuclear Information System (INIS)

    Larson, B.C.; Tischler, J.Z.

    1990-06-01

    Synchrotron sources provide exceptional opportunities for carrying out time-resolved x-ray diffraction investigations. The high intensity, high angular resolution, and continuously tunable energy spectrum of synchrotron x-ray beams lend themselves directly to carrying out sophisticated time-resolved x-ray scattering measurements on a wide range of materials and phenomena. When these attributes are coupled with the pulsed time-structure of synchrotron sources, entirely new time-resolved scattering possibilities are opened. Synchrotron beams typically consist of sub-nanosecond pulses of x-rays separated in time by a few tens of nanoseconds to a few hundred nanoseconds so that these beams appear as continuous x-ray sources for investigations of phenomena on time scales ranging from hours down to microseconds. Studies requiring time-resolution ranging from microseconds to fractions of a nanosecond can be carried out in a triggering mode by stimulating the phenomena under investigation in coincidence with the x-ray pulses. Time resolution on the picosecond scale can, in principle, be achieved through the use of streak camera techniques in which the time structure of the individual x-ray pulses are viewed as quasi-continuous sources with ∼100--200 picoseconds duration. Techniques for carrying out time-resolved scattering measurements on time scales varying from picoseconds to kiloseconds at present and proposed synchrotron sources are discussed and examples of time-resolved studies are cited. 17 refs., 8 figs

  2. ESR studies of radiation induced radical products from linoleic acid and linolenic acid and the radioprotective effect by α-tocopherol

    International Nuclear Information System (INIS)

    Zhu Younan; Tu Tiecheng; Dong Jirong; Zhang Jiashan; Li Nianyun

    1993-01-01

    Primary radicals from the γ-radiolysis of air-saturated linoleic acid and linolenic acid at 77 K, and the subsequent secondary radicals appeared during the course of variable temperature elevation were investigated by ESR. The ESR spectrum from samples irradiated and observed at 77 K shows the presence of the radical anion doublet arise from the electron adducts of the carboxy groups and the poorly resolved broad singlet results from some carbon-centered radicals. Annealing to approximately 125 K which allows for molecular oxygen migration results in the formation of peroxyl radicals. At 247 K, the ESR spectrum is a multi-line pattern which is attributable to structure of the α-carbon radical superimposed on the pentadienyl radicals. The ESR spectra from linoleic acid-α-tocopherol and linolenic acid-α-tocopherol binary systems irradiated at 77 K and recorded at 140 K or 215 K revealed the characteristic similarity to that from α-tocopherol alone, no trace of ESR signal from either peroxyl or the composite pattern from superposition of pentadienyl radical and α-carbon radicals can be found out. Therefore α-tocopherol has exerted radioprotection effect on peroxidation of linoleic acid and linolenic acid

  3. Time-resolved vibrational spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tokmakoff, Andrei [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Champion, Paul [Northeastern Univ., Boston, MA (United States); Heilweil, Edwin J. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Nelson, Keith A. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Ziegler, Larry [Boston Univ., MA (United States)

    2009-05-14

    This document contains the Proceedings from the 14th International Conference on Time-Resolved Vibrational Spectroscopy, which was held in Meredith, NH from May 9-14, 2009. The study of molecular dynamics in chemical reaction and biological processes using time-resolved spectroscopy plays an important role in our understanding of energy conversion, storage, and utilization problems. Fundamental studies of chemical reactivity, molecular rearrangements, and charge transport are broadly supported by the DOE's Office of Science because of their role in the development of alternative energy sources, the understanding of biological energy conversion processes, the efficient utilization of existing energy resources, and the mitigation of reactive intermediates in radiation chemistry. In addition, time-resolved spectroscopy is central to all fiveof DOE's grand challenges for fundamental energy science. The Time-Resolved Vibrational Spectroscopy conference is organized biennially to bring the leaders in this field from around the globe together with young scientists to discuss the most recent scientific and technological advances. The latest technology in ultrafast infrared, Raman, and terahertz spectroscopy and the scientific advances that these methods enable were covered. Particular emphasis was placed on new experimental methods used to probe molecular dynamics in liquids, solids, interfaces, nanostructured materials, and biomolecules.

  4. ESR study of free radicals in mango

    Science.gov (United States)

    Kikuchi, Masahiro; Hussain, Mohammad S.; Morishita, Norio; Ukai, Mitsuko; Kobayashi, Yasuhiko; Shimoyama, Yuhei

    2010-01-01

    An electron spin resonance (ESR) spectroscopic study of radicals induced in irradiated fresh mangoes was performed. Mangoes in the fresh state were irradiated with γ-rays, lyophilized and then crushed into a powder. The ESR spectrum of the powder showed a strong main peak at g = 2.004 and a pair of peaks centered at the main peak. The main peak was detected from both flesh and skin specimens. This peak height gradually decreased during storage following irradiation. On the other hand, the side peaks showed a well-defined dose-response relationship even at 9 days post-irradiation. The side peaks therefore provide a useful means to define the irradiation of fresh mangoes.

  5. ESR technique for noninvasive way to quantify cyclodextrins effect on cell membranes

    International Nuclear Information System (INIS)

    Grammenos, A.; Mouithys-Mickalad, A.; Guelluy, P.H.; Lismont, M.; Piel, G.; Hoebeke, M.

    2010-01-01

    Research highlights: → ESR: a new tool for cyclodextrins study on living cells. → Cholesterol and phospholipid extraction by Rameb in a dose- and time-dependent way. → Extracted phospholipids and cholesterol form stable aggregates. → ESR spectra show that lipid rafts are damaged by Rameb. → Quantification of the cholesterol extraction on cell membranes in a noninvasive way. -- Abstract: A new way to study the action of cyclodextrin was developed to quantify the damage caused on cell membrane and lipid bilayer. The Electron Spin Resonance (ESR) spectroscopy was used to study the action of Randomly methylated-beta-cyclodextrin (Rameb) on living cells (HCT-116). The relative anisotropy observed in ESR spectrum of nitroxide spin probe (5-DSA and cholestane) is directly related to the rotational mobility of the probe, which can be further correlated with the microviscosity. The use of ESR probes clearly shows a close correlation between cholesterol contained in cells and cellular membrane microviscosity. This study also demonstrates the Rameb ability to extract cholesterol and phospholipids in time- and dose-dependent ways. In addition, ESR spectra enabled to establish that cholesterol is extracted from lipid rafts to form stable aggregates. The present work supports that ESR is an easy, reproducible and noninvasive technique to study the effect of cyclodextrins on cell membranes.

  6. An ESR study on biological dosimeters: Human hair

    International Nuclear Information System (INIS)

    Colak, Seyda; Ozbey, Turan

    2011-01-01

    In the present work, characteristic features of the radicals found in untreated, gamma and UV-irradiated and mechanical damaged human hair samples were investigated by ESR spectroscopy. Heights of the resonance peaks measured with respect to the spectrum base line were used to monitor microwave power, dose-response, storage time and temperature dependent kinetic features of the radical species contributing to the formation of recorded experimental ESR spectra. Peak heights and g-values (2.0037-2.0052) determined from recorded spectra of hair were color dependent with ΔHpp-0.47 mT. The act of cutting hair samples gene rates sulfur centered radicals which are found in the a-keratin structure of hair. The variations of the peak heights with temperature were related with the water content found in the hair samples. In the 6-1100 Gy dose range, a linear + quadratic dose-response curve was recorded for hair and the mean radiation yield (G mean ) was calculated to be 0.4. The gamma radiation induced radicals were stable for a several hours at room temperature storage conditions. Based on these findings it was concluded that human hair samples could be used as biological/personnel dosimeters and that ESR spectroscopy could be successfully used as a potential technique for monitoring its dosimetric behaviours.

  7. Effects of alpha radiation on plutonium incorporated in dosimetric materials by ESR studies

    International Nuclear Information System (INIS)

    Bhide, M.K.; Kadam, R.M.; Mohapatra, Manoj; Godbole, S.V.

    2007-01-01

    The in situ alpha irradiation effects of some ESR dosimetric materials namely alanine, 2-methyl alanine and ammonium tartrate were studied by incorporating 1% plutonium by weight in them. The radical intensity was monitored as a function of alpha dose. It was found that in the dose region 1-35 kGy ammonium tartrate showed better signal intensity, linearity and dose response as compared to the other materials. This was attributed to the single radical produced in case of the tartrate giving a sharp spectrum and the fast relaxation times owing to less saturation of ESR signals. (author)

  8. ESR study on the interaction between carbon blacks and oxygen molecules; ESR ho ni yoru carbon black to sanso bunshi tono sogo sayo no kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Okazaki, M.; Toriyama, K.; Konishi, Y. [National Industrial Research Institute of Nagoya, Nagoya (Japan)

    2000-02-24

    Interaction between carbon blacks and oxygen molecules has been studied by means of electron spin resonance (ESR) spectroscopy. The ESR spectra of the carbon blacks appears at the g-value of free spin, which are contributed by both isolated electrons and conduction electrons. Upon introducing oxygen to the system the ESR linewidth was broadened in proportion to the partial pressure of oxygen. In case of lampblack (LB 101, Degussa) the interaction was not so strong that it took a tong time at 77K for the linewidth to reach the maxmum value. In case of gassblack (P 140 V, Degussa), on the other hand, the oxygen was easily adsorbed at 298K and the linewidth at 77K became its maximum immediately after cooling. The number of unpaired electrons decreased when the system was kept at 298 K and the decrease was prominent for the local spins. These phenomena have been explained with a simple band model for the electron. (author)

  9. ESR and microbiological studies on gamma radiation processed dehydrated onion powder

    International Nuclear Information System (INIS)

    Khedkar, K.C.; Kumbhare, M.N.; Sharma, G.; Lavale, D.S.; Kadam, R.M.; Bhide, M.K.; Sastry, M.D.

    2001-01-01

    Paper describes the potential of ESR technique for detection of free radicals produced in the irradiated onion powder. Experiments were carried out to evaluate the effect of light, moisture and time on the stability of free radicals produced by gamma radiation. Some microbiological studies were also carried out on unprocessed and radiation-processed product. (author)

  10. Diffusion studies on permeable nitroxyl spin probes through bilayer lipid membranes: A low frequency ESR study

    International Nuclear Information System (INIS)

    Meenakumari, V.; Benial, A. Milton Franklin; Utsumi, Hideo; Ichikawa, Kazuhiro; Yamada, Ken-ichi; Hyodo, Fuminori; Jawahar, A.

    2015-01-01

    Electron spin resonance (ESR) studies were carried out for permeable 2mM 14 N-labeled deutrated 3 Methoxy carbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) in pure water and 1mM, 2mM, 3mM, 4mM concentration of 14N-labeled deutrated MC-PROXYL in 400mM concentration of liposomal solution by using a 300 MHz ESR spectrometer. The ESR parameters such as linewidth, hyperfine coupling constant, g-factor, partition parameter and permeability were reported for these samples. The line broadening was observed for the nitroxyl spin probe in the liposomal solution. The line broadening indicates that the high viscous nature of the liposomal solution. The partition parameter and permeability values indicate the maximum diffusion of nitroxyl spin probes in the bilayer lipid membranes at 2 mM concentration of nitroxyl radical. This study illustrates that ESR can be used to differentiate between the intra and extra- membrane water by loading the liposome vesicles with a lipid-permeable nitroxyl spin probe. From the ESR results, the spin probe concentration was optimized as 2mM in liposomal solution for ESR phantom studies/imaging, invivo and invitro experiments

  11. ESR studies of high-energy phosphorus-ion implanted synthetic diamond crystals

    Energy Technology Data Exchange (ETDEWEB)

    Isoya, J [University of Library and Information Science, Tsukuba, Ibaraki (Japan); Kanda, H; Morita, Y; Ohshima, T

    1997-03-01

    Phosphorus is among potential n-type dopants in diamond. High pressure synthetic diamond crystals of type IIa implanted with high energy (9-18 MeV) phosphorus ions have been studied by using electron spin resonance (ESR) technique. The intensity and the linewidth of the ESR signal attributed to the dangling bond of the amorphous phase varied with the implantation dose, suggesting the nature of the amorphization varies with the dose. The ESR signals of point defects have been observed in the low dose as-implanted crystals and in the high dose crystals annealed at high temperature and at high pressure. (author)

  12. Preliminary study on the detection of irradiated food containing bone by ESR spectroscopy

    International Nuclear Information System (INIS)

    Zhao Yongfu; Ha Yiming; Liu Ting; Wang Rongfu; Wang Changbao

    2007-01-01

    Electron spin resonance (ESR) spectroscopy is one of the most effective technique for detection of irradiated food containing bone. It was found that the radiation -induced ESR signal (Spectrum, g factor and peak-to-peak line width AH) in bone before and after irradiation was significantly different and could be easily distinguished from the endogenous ESR signal. Sample preparation studies showed vacuum drying and grinding at frozen temperature was an ideal method. A linear relationship was observed between ESR signal intensity and the absorbed dose (0.3-10.1kGy). It can be proposed that 0.5kGy absorbed doses can be detected by ESR for irradiated food containing bone though detecting sensitivity is very different at the same irradiated dosage with different food such as pork, beef, duck, chicken and fish. The ultimate purpose of this work is to establish a national criterion for detection of irradiated foodstuffs by use of ESR. (authors)

  13. Analysis of radicals induced in irradiated cereal flour using ESR

    International Nuclear Information System (INIS)

    Kawamura, Shoei; Kishita, Keigo; Ukai, Mitsuko; Kikuchi, Masahiro; Kobayashi, Yasuhiko

    2013-01-01

    Using electron spin resonance (ESR) spectroscopy, we revealed radicals induced in cereal flour irradiated with gamma-ray or electron beam. Sample was wheat and rice. We detected a broad singlet signal at g = 2.0. It consists of a singlet signal and a triplet signal. It suggested that the singlet signal is originated from organic free radicals and the triplet signal is from 14 N. There were no differences of ESR spectra between irradiated wheat flour and rice flour. The signal intensity of radiation induced radical was tend to increase following with the increase of radiation dose level. After radiation treatment, relaxation time of radiation induced radical was changed during storage. T 1 was decreased and T 2 was increased. In this study, the relaxation time is calculated using the parameters obtained from the ESR signal. It is necessary to analyze the relaxation time directly with pulsed ESR spectroscopy in future. (author)

  14. ESR dating of fault rocks

    International Nuclear Information System (INIS)

    Lee, Hee Kwon

    2003-02-01

    Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then grow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs. grain size shows a plateau for grains below critical size; these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected near the Gori nuclear reactor. Most of the ESR signals of fault rocks collected from the basement are saturated. This indicates that the last movement of the faults had occurred before the Quaternary period. However, ESR dates from the Oyong fault zone range from 370 to 310 ka. Results of this research suggest that long-term cyclic fault activity of the Oyong fault zone continued into the Pleistocene

  15. ESR dating of fault rocks

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Kwon [Kangwon National Univ., Chuncheon (Korea, Republic of)

    2003-02-15

    Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then grow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs. grain size shows a plateau for grains below critical size; these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected near the Gori nuclear reactor. Most of the ESR signals of fault rocks collected from the basement are saturated. This indicates that the last movement of the faults had occurred before the Quaternary period. However, ESR dates from the Oyong fault zone range from 370 to 310 ka. Results of this research suggest that long-term cyclic fault activity of the Oyong fault zone continued into the Pleistocene.

  16. Time-resolved spectroscopy in synchrotron radiation

    International Nuclear Information System (INIS)

    Rehn, V.; Stanford Univ., CA

    1980-01-01

    Synchrotron radiation (SR) from large-diameter storage rings has intrinsic time structure which facilitates time-resolved measurements form milliseconds to picoseconds and possibly below. The scientific importance of time-resolved measurements is steadily increasing as more and better techniques are discovered and applied to a wider variety of scientific problems. This paper presents a discussion of the importance of various parameters of the SR facility in providing for time-resolved spectroscopy experiments, including the role of beam-line optical design parameters. Special emphasis is placed on the requirements of extremely fast time-resolved experiments with which the effects of atomic vibrational or relaxation motion may be studied. Before discussing the state-of-the-art timing experiments, we review several types of time-resolved measurements which have now become routine: nanosecond-range fluorescence decay times, time-resolved emission and excitation spectroscopies, and various time-of-flight applications. These techniques all depend on a short SR pulse length and a long interpulse period, such as is provided by a large-diameter ring operating in a single-bunch mode. In most cases, the pulse shape and even the stability of the pulse shape is relatively unimportant as long as the pulse length is smaller than the risetime of the detection apparatus, typically 1 to 2 ns. For time resolution smaller than 1 ns, the requirements on the pulse shape become more stringent. (orig./FKS)

  17. ESR dating studies on fossil of elaphurus davidianus horn

    International Nuclear Information System (INIS)

    Chen Shiming; Wang Hong; Tang Jingjuan; Yan Xiaomin; Guo Shiqing

    1991-01-01

    On the basis of studies on elephant tooth fossil, ESR dating of elaphurus davidianus horn fossil found in Anhui Province was reported. The sample examined by TEM electron spectrum is composed of hydroxyapatite. ESR experiments showed that the solid bone sample can be chosen as dating material. According to the contents of U, Th and K in the sample determined by ICP, the annual dose of radiation was calculated by using the linear uranium accumulation model and disequilibrium decay. The age of this fossil was determined to be 2.5 x 10 4 years

  18. Efficiency and rate capability studies of the time-of-flight detector for isochronous mass measurements of stored short-lived nuclei with the FRS-ESR facility

    Energy Technology Data Exchange (ETDEWEB)

    Kuzminchuk-Feuerstein, Natalia; Fabian, Benjamin [II. Physikalisches Institut, Justus-Liebig-Universität, 35392 Gießen (Germany); GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt (Germany); Diwisch, Marcel [II. Physikalisches Institut, Justus-Liebig-Universität, 35392 Gießen (Germany); Plaß, Wolfgang R., E-mail: Wolfgang.R.Plass@exp2.physik.uni-giessen.de [II. Physikalisches Institut, Justus-Liebig-Universität, 35392 Gießen (Germany); GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt (Germany); Geissel, Hans; Ayet San Andrés, Samuel; Dickel, Timo; Knöbel, Ronja; Scheidenberger, Christoph [II. Physikalisches Institut, Justus-Liebig-Universität, 35392 Gießen (Germany); GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt (Germany); Sun, Baohua [II. Physikalisches Institut, Justus-Liebig-Universität, 35392 Gießen (Germany); Weick, Helmut [GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt (Germany)

    2016-06-11

    A time-of-flight (TOF) detector is used for Isochronous Mass Spectrometry (IMS) with the projectile fragment separator FRS and the heavy-ion storage ring ESR. Exotic nuclei are spatially separated in flight with the FRS at about 70% of the speed of light and are injected into the ESR. The revolution times of the stored ions circulating in the ESR are measured with a thin transmission foil detector. When the ions penetrate the thin detector foil, secondary electrons (SEs) are emitted from the surface and provide the timing information in combination with microchannel plate (MCP) detectors. The isochronous transport of the SEs is performed by perpendicular superimposed electric and magnetic fields. The detection efficiency and the rate capability of the TOF detector have been studied in simulations and experiments. As a result the performance of the TOF detector has been improved substantially: (i) The SE collection efficiency was doubled by use of an optimized set of electric and magnetic field values; now SEs from almost the full area of the foil are transmitted to the MCP detectors. (ii) The rate capability of the TOF detector was improved by a factor of four by the use of MCPs with 5 μm pore size. (iii) With these MCPs and a carbon foil with a reduced thickness of 10 μg/cm{sup 2} the number of recorded revolutions in the ESR has been increased by nearly a factor of 10. The number of recorded revolutions determine the precision of the IMS experiments. Heavy-ion measurements were performed with neon ions at 322 MeV/u and uranium fission fragments at about 370 MeV/u. In addition, measurements with an alpha source were performed in the laboratory with a duplicate of the TOF detector.

  19. Efficiency and rate capability studies of the time-of-flight detector for isochronous mass measurements of stored short-lived nuclei with the FRS-ESR facility

    International Nuclear Information System (INIS)

    Kuzminchuk-Feuerstein, Natalia; Fabian, Benjamin; Diwisch, Marcel; Plaß, Wolfgang R.; Geissel, Hans; Ayet San Andrés, Samuel; Dickel, Timo; Knöbel, Ronja; Scheidenberger, Christoph; Sun, Baohua; Weick, Helmut

    2016-01-01

    A time-of-flight (TOF) detector is used for Isochronous Mass Spectrometry (IMS) with the projectile fragment separator FRS and the heavy-ion storage ring ESR. Exotic nuclei are spatially separated in flight with the FRS at about 70% of the speed of light and are injected into the ESR. The revolution times of the stored ions circulating in the ESR are measured with a thin transmission foil detector. When the ions penetrate the thin detector foil, secondary electrons (SEs) are emitted from the surface and provide the timing information in combination with microchannel plate (MCP) detectors. The isochronous transport of the SEs is performed by perpendicular superimposed electric and magnetic fields. The detection efficiency and the rate capability of the TOF detector have been studied in simulations and experiments. As a result the performance of the TOF detector has been improved substantially: (i) The SE collection efficiency was doubled by use of an optimized set of electric and magnetic field values; now SEs from almost the full area of the foil are transmitted to the MCP detectors. (ii) The rate capability of the TOF detector was improved by a factor of four by the use of MCPs with 5 μm pore size. (iii) With these MCPs and a carbon foil with a reduced thickness of 10 μg/cm 2 the number of recorded revolutions in the ESR has been increased by nearly a factor of 10. The number of recorded revolutions determine the precision of the IMS experiments. Heavy-ion measurements were performed with neon ions at 322 MeV/u and uranium fission fragments at about 370 MeV/u. In addition, measurements with an alpha source were performed in the laboratory with a duplicate of the TOF detector.

  20. Establishment of estrogen receptor 1 (ESR1)-knockout medaka: ESR1 is dispensable for sexual development and reproduction in medaka, Oryzias latipes.

    Science.gov (United States)

    Tohyama, Saki; Ogino, Yukiko; Lange, Anke; Myosho, Taijun; Kobayashi, Tohru; Hirano, Yu; Yamada, Gen; Sato, Tomomi; Tatarazako, Norihisa; Tyler, Charles R; Iguchi, Taisen; Miyagawa, Shinichi

    2017-08-01

    Estrogens play fundamental roles in regulating reproductive activities and they act through estrogen receptor (ESR) in all vertebrates. Most vertebrates have two ESR subtypes (ESR1 and ESR2), whereas teleost fish have at least three (Esr1, Esr2a and Esr2b). Intricate functionalization has been suggested among the Esr subtypes, but to date, distinct roles of Esr have been characterized in only a limited number of species. Study of loss-of-function in animal models is a powerful tool for application to understanding vertebrate reproductive biology. In the current study, we established esr1 knockout (KO) medaka using a TALEN approach and examined the effects of Esr1 ablation. Unexpectedly, esr1 KO medaka did not show any significant defects in their gonadal development or in their sexual characteristics. Neither male or female esr1 KO medaka exhibited any significant changes in sexual differentiation or reproductive activity compared with wild type controls. Interestingly, however, estrogen-induced vitellogenin gene expression, an estrogen-responsive biomarker in fish, was limited in the liver of esr1 KO males. Our findings, in contrast to mammals, indicate that Esr1 is dispensable for normal development and reproduction in medaka. We thus provide an evidence for estrogen receptor functionalization between mammals and fish. Our findings will also benefit interpretation of studies into the toxicological effects of estrogenic chemicals in fish. © 2017 Japanese Society of Developmental Biologists.

  1. ESR dating of fault rocks

    International Nuclear Information System (INIS)

    Lee, Hee Kwon

    2002-03-01

    Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then trow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs grain size shows a plateau for grains below critical size : these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected from the Yangsan fault system. ESR dates from the this fault system range from 870 to 240 ka. Results of this research suggest that long-term cyclic fault activity continued into the pleistocene

  2. ESR dating of fault rocks

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Kwon [Kangwon National Univ., Chuncheon (Korea, Republic of)

    2002-03-15

    Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then trow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs grain size shows a plateau for grains below critical size : these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected from the Yangsan fault system. ESR dates from the this fault system range from 870 to 240 ka. Results of this research suggest that long-term cyclic fault activity continued into the pleistocene.

  3. Lyoluminescence and ESR correlation studies of trehalose dihydrate

    Energy Technology Data Exchange (ETDEWEB)

    Raman, Anand E-mail: anandr@apsara.barc.ernet.in; Oommen, Issac K.; Gundu Rao, T.K.; Sharma, D.N

    2002-07-01

    ESR studies of irradiated lyoluminescence (LL) phosphor, trehalose dihydrate showed a linear free radical growth up to a dose of 11 kGy. The LL output measured under oxygen equilibrated conditions showed an extension of the dosimetric response from 0.6 to 6 kGy. ESR spectral analysis indicates the formation of two radical species viz., 'a' and 'b' and their involvement in the LL process. The estimated free radical concentrations of radicals 'a' and 'b' were found to be 6.81x10{sup 15} and 1.35x10{sup 16} g{sup -1}, respectively, for a gamma dose of 10.8 kGy.

  4. Permeability studies of redox-sensitive nitroxyl spin probes in corn oil using an L-band ESR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Jebaraj, D. David [Department of Physics, The American College, Madurai-625 002, Tamilnadu (India); Utsumi, Hideo [Innovation Center for Medical Redox Navigation, Kyushu University, Fukuoka 812-8582 (Japan); Asath, R. Mohamed; Benial, A. Milton Franklin, E-mail: miltonfranklin@yahoo.com [Department of Physics, NMSSVN College, Madurai-625 019, Tamilnadu (India)

    2016-05-23

    Electron spin resonance (ESR) studies were carried out for 2mM {sup 14}N labeled {sup 2}H enriched 3-methoxycarbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) and 3–carboxy-2,2,5,5,-tetramethyl-1-pyrrolidinyloxy (carboxy-PROXYL) in pure water and various concentrations of corn oil. The ESR parameters, such as the line width, hyperfine coupling constant, g-factor, rotational correlation time, partition parameter and permeability were reported for the samples. The line width broadening was observed for both nitroxyl radicals in corn oil solutions. The partition parameter for permeable MC-PROXYL in corn oil increases with increasing concentration of corn oil, which reveals that the nitroxyl spin probe permeates into the oil phase. From the results, the corn oil concentration was optimized as 50 % for phantom studies. The rotational correlation time also increases with increasing concentration of corn oil. The permeable and impermeable nature of nitroxyl spin probes was demonstrated. These results will be useful for the development of ESR/OMR imaging modalities in in vivo and in vitro studies.

  5. Permeability studies of redox-sensitive nitroxyl spin probes in corn oil using an L-band ESR spectrometer

    International Nuclear Information System (INIS)

    Jebaraj, D. David; Utsumi, Hideo; Asath, R. Mohamed; Benial, A. Milton Franklin

    2016-01-01

    Electron spin resonance (ESR) studies were carried out for 2mM 14 N labeled 2 H enriched 3-methoxycarbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) and 3–carboxy-2,2,5,5,-tetramethyl-1-pyrrolidinyloxy (carboxy-PROXYL) in pure water and various concentrations of corn oil. The ESR parameters, such as the line width, hyperfine coupling constant, g-factor, rotational correlation time, partition parameter and permeability were reported for the samples. The line width broadening was observed for both nitroxyl radicals in corn oil solutions. The partition parameter for permeable MC-PROXYL in corn oil increases with increasing concentration of corn oil, which reveals that the nitroxyl spin probe permeates into the oil phase. From the results, the corn oil concentration was optimized as 50 % for phantom studies. The rotational correlation time also increases with increasing concentration of corn oil. The permeable and impermeable nature of nitroxyl spin probes was demonstrated. These results will be useful for the development of ESR/OMR imaging modalities in in vivo and in vitro studies.

  6. ESR dating of the fault rocks

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Kwon [Kangwon National Univ., Chuncheon (Korea, Republic of)

    2004-01-15

    Past movement on faults can be dated by measurement of the intensity of ESR signals in quartz. These signals are reset by local lattice deformation and local frictional heating on grain contacts at the time of fault movement. The ESR signals then grow back as a result of bombardment by ionizing radiation from surrounding rocks. The age is obtained from the ratio of the equivalent dose, needed to produce the observed signal, to the dose rate. Fine grains are more completely reset during faulting, and a plot of age vs, grain size shows a plateau for grains below critical size : these grains are presumed to have been completely zeroed by the last fault activity. We carried out ESR dating of fault rocks collected near the Ulzin nuclear reactor. ESR signals of quartz grains separated from fault rocks collected from the E-W trend fault are saturated. This indicates that the last movement of these faults had occurred before the quaternary period. ESR dates from the NW trend faults range from 300ka to 700ka. On the other hand, ESR date of the NS trend fault is about 50ka. Results of this research suggest that long-term cyclic fault activity near the Ulzin nuclear reactor continued into the pleistocene.

  7. Elaboration And Study Of Transfer Alanine/ESR Dosemeters

    International Nuclear Information System (INIS)

    Torres G, Luz A.

    1996-01-01

    The dosimetry is the dose measure imparted by the energy from the ionizing radiation to the matter. The dosemeters is the means used for the determination of such a dose. Diverse dosimetric classes exist, this classification depends in essence of the energy involved in the irradiation process and of its application necessity. It is as well as in radiological protection movie dosemeter is used, and TLD, in the calibration of units, as those of cobalt, the ionization cameras are used, in the detection of superficial contamination the accountants Geiger Muller and proportional etc. The transfer dosimeter Alanine/ESR is used, object of the present work, is characterized because after reading the registered dose, the information is conserved and it can be transferred and read in any team of ESR. Likewise the following dose that is imparted will be added to the previous one registered, this indicates that the dosemeters is of integral character. In the spectra taken ESR, it is determined that the integral double or area under the curve of the spectrum ESR is proportional to the concentration of free radicals generated by the radiation ionization and in turn this concentration is proportional to the dose received by the pills; in last, these proportionality relationships take to that the area under the curve of the spectrum main ESR is proportional to the radiation dose received by the alanine dosemeters. This dosemeter seeks to be an economic alternative that it will lend the calibration service that today offers the ionization Cameras or the acrylic red industrial dosemeters

  8. Ribavirin restores ESR1 gene expression and tamoxifen sensitivity in ESR1 negative breast cancer cell lines

    Directory of Open Access Journals (Sweden)

    Sappok Anne

    2011-12-01

    Full Text Available Abstract Tumor growth is estrogen independent in approximately one-third of all breast cancers, which makes these patients unresponsive to hormonal treatment. This unresponsiveness to hormonal treatment may be explained through the absence of the estrogen receptor alpha (ESR1. The ESR1 gene re-expression through epigenetic modulators such as DNA methyltransferase inhibitors and/or histone deacetylase inhibitors restores tamoxifen sensitivity in ESR1 negative breast cancer cell lines and opens new treatment horizons in patients who were previously associated with a poor prognosis. In the study presented herein, we tested the ability of ribavirin, which shares some structural similarities with the DNA-methyltransferase inhibitor 5-azacytidine and which is widely known as an anti-viral agent in the treatment of hepatitis C, to restore ESR1 gene re-expression in ESR1 negative breast cancer cell lines. In our study we identified ribavirin to restore ESR1 gene re-expression alone and even more in combination with suberoylanilide hydroxamic acid (SAHA - up to 276 fold induction. Ribavirin and analogs could pave the way to novel translational research projects that aim to restore ESR1 gene re-expression and thus the susceptibility to tamoxifen-based endocrine treatment strategies.

  9. Study by electron spin resonance (ESR) of 60 Co irradiated grains and farinaceous derivatives

    International Nuclear Information System (INIS)

    Catanni, Marta Mattos.

    1995-01-01

    The electron spin resonance (ESR) spectroscopy is being pointed out as one of the most promising techniques to determine whether a food has been irradiated. In this work, the ESR spectrum of paramagnetic radicals produced by gamma irradiation of grains and flour derivatives using a 60 Co source was investigated. Samples of grains (wheat and barley), flours (wheat, maniac, rye, soy bean and maize), bran and starch have been irradiated with doses between 0.2 and 70 KGy. It was shown that all varieties of grains and flours presented similar ESR spectra with variation in the free radicals signal intensity. Measurements at 9.5 and 34.5 GHz shown that spectra were composed probably by the superposition of four paramagnetic species with g-factors closed to that of the free electron (2 triplets, 1 doublet and 1 singlet). Hyperfine interactions and the correspondingly line widths were estimated through an spectrum computer simulation. It was established that ESR signal intensities increased with the irradiation dose for all samples. Up to the commercial admissible dose limit (1 kGy), the increase of ESR signal shown a linear behavior with the dose. The signal stability varied significantly with storage conditions and sample humidity. For 1 kGy-irradiated samples stored at room temperature and 14% humidity, the ESR radiation signals were possible to be detected up to 5 days after irradiation. When the same samples were stored at low temperatures (0 0 C) or freeze-dried (almost 0% humidity) the ESR signals were detected until 6 months after irradiation. Similar ESR spectrum found for grains and flours was obtained for diverse starchy food products. It was verified that it is possible to identify for a long time irradiated starchy foods when they are commercialized dehydrated or frozen. (author). 66 refs., 35 figs., 17 tabs

  10. Electron spin resonance (ESR) studies on irradiated cocoa beans and niger seeds

    International Nuclear Information System (INIS)

    Mangaonkar, S.R.; Natarajan, V.; Sastry, M.D.; Desai, S.R.P.; Kulkarni, P.R.

    1997-01-01

    Electron spin resonance (ESR) spectra of irradiated (10kGy) and unirradiated cocoa beans and niger seeds have been compared. Unirradiated cocoa beans failed to give any ESR signal, whereas after irradiation (10kGy) an ESR signal at g = 2.0042 was observed. However, ESR signals are given by both irradiated and unirradiated niger seeds. The intensity of signal was found to be dose-dependent up to 10kGy for both seeds. The signals were stable up to 180 days in both cases. The results indicate the possibility of using ESR for distinguishing between irradiated and unirradiated cocoa beans but not for niger seeds

  11. Scalable control of mounting and attack by Esr1+ neurons in the ventromedial hypothalamus.

    Science.gov (United States)

    Lee, Hyosang; Kim, Dong-Wook; Remedios, Ryan; Anthony, Todd E; Chang, Angela; Madisen, Linda; Zeng, Hongkui; Anderson, David J

    2014-05-29

    Social behaviours, such as aggression or mating, proceed through a series of appetitive and consummatory phases that are associated with increasing levels of arousal. How such escalation is encoded in the brain, and linked to behavioural action selection, remains an unsolved problem in neuroscience. The ventrolateral subdivision of the murine ventromedial hypothalamus (VMHvl) contains neurons whose activity increases during male-male and male-female social encounters. Non-cell-type-specific optogenetic activation of this region elicited attack behaviour, but not mounting. We have identified a subset of VMHvl neurons marked by the oestrogen receptor 1 (Esr1), and investigated their role in male social behaviour. Optogenetic manipulations indicated that Esr1(+) (but not Esr1(-)) neurons are sufficient to initiate attack, and that their activity is continuously required during ongoing agonistic behaviour. Surprisingly, weaker optogenetic activation of these neurons promoted mounting behaviour, rather than attack, towards both males and females, as well as sniffing and close investigation. Increasing photostimulation intensity could promote a transition from close investigation and mounting to attack, within a single social encounter. Importantly, time-resolved optogenetic inhibition experiments revealed requirements for Esr1(+) neurons in both the appetitive (investigative) and the consummatory phases of social interactions. Combined optogenetic activation and calcium imaging experiments in vitro, as well as c-Fos analysis in vivo, indicated that increasing photostimulation intensity increases both the number of active neurons and the average level of activity per neuron. These data suggest that Esr1(+) neurons in VMHvl control the progression of a social encounter from its appetitive through its consummatory phases, in a scalable manner that reflects the number or type of active neurons in the population.

  12. Time-resolved X-ray studies using third generation synchrotron radiation sources

    International Nuclear Information System (INIS)

    Mills, D.M.

    1991-10-01

    The third generation, high-brilliance, hard x-ray, synchrotron radiation (SR) sources currently under construction (ESRF at Grenoble, France; APS at Argonne, Illinois; and SPring-8 at Harima, Japan) will usher in a new era of x-ray experimentation for both physical and biological sciences. One of the most exciting areas of experimentation will be the extension of x-ray scattering and diffraction techniques to the study of transient or time-evolving systems. The high repetition rate, short-pulse duration, high brilliance, and variable spectral bandwidth of these sources make them ideal for x-ray time-resolved studies. The temporal properties (bunch length, interpulse period, etc.) of these new sources will be summarized. Finally, the scientific potential and the technological challenges of time-resolved x-ray scattering from these new sources will be described. 13 refs., 4 figs

  13. Non-linear effects in the radiolysis-optically detected ESR of radical-ion pairs in liquid and glassy solutions. Reactions and motion of organic radicals as studied by ESR and OD ESR spectroscopy

    International Nuclear Information System (INIS)

    Antzutkin, O.

    1992-01-01

    This thesis is divided into two sections. The first part covers an introduction to the Optically Detected Electron Spin Resonance (OD ESR) spectroscopy and a short description of the OD ESR spectrometer built in Linkoeping University in 1991. In the second section the following topics are discussed: Non-linear effects in OD ESR spectroscopy and Reactions and motion of organic radicals trapped in freon matrices. (19 refs.)

  14. Study of free-radical centers in lignin with 2-mm band ESR spectroscopy

    International Nuclear Information System (INIS)

    Kuzina, S.I.; Demidov, S.V.; Brezgunov, A.Yu.; Poluehktov, O.G.; Grinberg, O.Ya.; Dubinskij, A.A.; Mikhajlov, A.I.; Lebedev, Ya.S.

    1993-01-01

    The nature of paramagnetic centers in pristine lignin and lignin, treated with molecular chlorine, aqueous solutions of acids and alkalis, and γ- and UV-irradiated, was studied with 2-mm band ESR spectroscopy. Most of the observed singlet ESR lines are accounted for by radicals with conjugated bonds. High reactivity of double bonds of polyconjugated systems was in the processes studied

  15. ESR Dosimetry

    International Nuclear Information System (INIS)

    Baffa, Oswaldo; Rossi, Bruno; Graeff, Carlos; Kinoshita, Angela; Chen Abrego, Felipe; Santos, Adevailton Bernardo dos

    2004-01-01

    ESR dosimetry is widely used for several applications such as dose assessment in accidents, medical applications and sterilization of food and other materials. In this work the dosimetric properties of natural and synthetic Hydroxyapatite, Alanine, and 2-Methylalanine are presented. Recent results on the use of a K-Band (24 GHz) ESR spectrometer in dosimetry are also presented

  16. Identification of irradiated sage tea (Salvia officinalis L.) by ESR spectroscopy

    International Nuclear Information System (INIS)

    Tepe Cam, Semra; Engin, Birol

    2010-01-01

    The use of electron spin resonance (ESR) spectroscopy to accurately distinguish irradiated from unirradiated sage tea was examined. Before irradiation, sage tea samples exhibit one asymmetric singlet ESR signal centered at g=2.0037. Besides this central signal, two weak satellite signals situated about 3 mT left and right to it in radiation-induced spectra. Irradiation with increasing doses caused a significant increase in radiation-induced ESR signal intensity at g=2.0265 (the left satellite signal) and this increase was found to be explained by a polynomial varying function. The stability of that radiation-induced ESR signal at room temperature was studied over a storage period of 9 months. Also, the kinetic of signal at g=2.0265 was studied in detail over a temperature range 313-353 K by annealing samples at different temperatures for various times.

  17. Identification of irradiated sage tea (Salvia officinalis L.) by ESR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tepe Cam, Semra, E-mail: stepe06@gmail.co [Gazi University, Faculty of Medicine, Biophysics Department, 06500 Besevler, Ankara (Turkey); Engin, Birol [Turkish Atomic Energy Authority, Saraykoey Nuclear Research and Training Center, 06983 Ankara (Turkey)

    2010-04-15

    The use of electron spin resonance (ESR) spectroscopy to accurately distinguish irradiated from unirradiated sage tea was examined. Before irradiation, sage tea samples exhibit one asymmetric singlet ESR signal centered at g=2.0037. Besides this central signal, two weak satellite signals situated about 3 mT left and right to it in radiation-induced spectra. Irradiation with increasing doses caused a significant increase in radiation-induced ESR signal intensity at g=2.0265 (the left satellite signal) and this increase was found to be explained by a polynomial varying function. The stability of that radiation-induced ESR signal at room temperature was studied over a storage period of 9 months. Also, the kinetic of signal at g=2.0265 was studied in detail over a temperature range 313-353 K by annealing samples at different temperatures for various times.

  18. ESR Spectroscopy for the Study of Oxidative Processes in Food and Beverages

    DEFF Research Database (Denmark)

    Andersen, Mogens Larsen; Skibsted, Leif Horsfelt

    2018-01-01

    Radicals are intermediates in many reactions that deteriorate foods. The detection of radicals by electron spin resonance, ESR, can provide mechanistic and uantitative information about these reactions, which has led to ESR-based methods for early prediction of shelf life of foods and beverages....... ESR is also used for monitoring irradiated foods, since the generated radicals are often quite stable. ESR can moreover give important information about oxidation mechanisms and microscopic physical structural aspects, which is useful for developing protective measures against oxidation in food....

  19. ESR Dating Research of Glacial Tills in Tibetan Plateau

    Science.gov (United States)

    Bi, W.; Yi, C.

    2016-12-01

    In recent years, Quaternary Glacial-chronology has been made remarkable progress in the Tibetan Platean(TP) with the development of several numeric dating techniques, such as cosmogenic nuclides(NC), optically stimulated luminescence(OSL) and 14C. In constrast, the dating of Quaternary glacial tills in 100,000 years even more than million-year has been a challenge, just because the techniques has defects themselves and the sediments were stransformed during the geological and geomorphology progress later. Electron Spin Resonance(ESR) has been becoming one of the key methods of Quaternary Glacial-chronology with wide range of dating, expecially for the sample older than 100,000 years up to million-year scale. The accurate measurement of equivalent dose significantly impacts on accuracy and reliability of ESR dating method. Therefore, the study of the mechanisms of resetting processes is fundamental for accurate and reliable ESR dating. To understand the mechanism and characteristics of quartz ESR signal resetting of different samples, a series of laboratory simulation and field observation studies were carried out, which made lots of important breakthrough. But the research in quartz ESR signal of moraines is less and the test of ESR dating method is still in the qualitative investigation. Therefor, we use ESR dating and study on the mechanism and characteristics of quartz ESR signals in tills in the Tibetan Platean. In the adjust method of Modern, the quartz ESR signals in Modern glacial tills represent residual values which can be adjusted signals in the older glacial tills. As a consequence, ESR dating of the quartz in moraines needs to be explored in deep with building models to adjust ages which are measured by ESR dating. Therefore, ESR dating will become the trusted one of the cross dating methods in Quaternary Glacial-chronology with the adjust mothod improving the accuracy of ESR dating ages.

  20. Time-resolved quantitative phosphoproteomics

    DEFF Research Database (Denmark)

    Verano-Braga, Thiago; Schwämmle, Veit; Sylvester, Marc

    2012-01-01

    proteins involved in the Ang-(1-7) signaling, we performed a mass spectrometry-based time-resolved quantitative phosphoproteome study of human aortic endothelial cells (HAEC) treated with Ang-(1-7). We identified 1288 unique phosphosites on 699 different proteins with 99% certainty of correct peptide...

  1. X-band ESR study on evaluation of radicals induced in pasteurized pepper

    International Nuclear Information System (INIS)

    Matsuura, Masaaki; Ogawa, Satoko; Ukai, Mitsuko; Oowada, Shigeru

    2007-01-01

    The radical properties of pasteurized pepper were investigated by means of X-band ESR spectroscopy. Pasteurization process was done by irradiation or steam. There were three radicals in the specimens before and after pasteurization. Upon irradiation a new radical was found. ESR peak intensity of specimen before and after parturition with steam was almost same level. Peak intensity of radiated pepper showed almost 4 times as compare with that of non treated pepper. Radical activity of the specimens after pasteurization showed almost same value. We concluded that radicals were induced by irradiation. But the radical activity was not changed before and after pasteurization. (author)

  2. ESR studies on degradation processes in polyethyleneterephtalate

    International Nuclear Information System (INIS)

    Chipara, M.; Chipara, M.D.; Georgescu, L.; Constantinescu, L.; Morosanu, C.

    2002-01-01

    Complete text of publication follows. The generation of free radicals by degradation processes (thermal, plasma and radiation induced) is analyzed. Details regarding the generation of free radicals, their interactions, and kinetics, as revealed by electron spin resonance (ESR), with emphasis on laser beam degradation, are discussed. Some ESR lines of laser-irradiated polyethyleneterephtalate (PET), recorded at room temperature, are shown in Figure 1. The lines are narrow singlets located around g=2.003. The resonance line amplitude, width and double integral of the resonance line are affected by the power of the incident beam. The common features of these degradation processes (universal behavior) as well as the fingerprints of each degradation process are analyzed in detail

  3. ESR (Electronic Spin Resonance Spectroscopy) study of irradiated paper for biomedical material wrapping

    International Nuclear Information System (INIS)

    Huarte, Monica; Rubin de Celis, Emilio; Kairiyama, Eulogia; Zapata, Miguel; Santoro, Natalia; Magnavacca, Cecilia

    2009-01-01

    Ionising radiation treatments are used for sterilization, microbiological decontamination, disinfection, insect disinfestation and food preservation. This ionising radiation generates free radicals (FR) in matter, which can be detected by Electronic Spin Resonance Spectroscopy (ESR). For this work it had analysed different kind of irradiated package papers of syringes, surgical gloves and dressings by ESR. These were irradiated with doses between 20 and 35 kGy of gamma radiation (Cobalt 60). The processed samples were measured in a Bruker ECS 106 spectrometer. The obtained results were: 1-) The irritated samples showed a central peak and two satellites induced by the applied radiation; 2-) The non-irradiated samples did not show the characteristic satellite peaks of the irritated ones; 3-) A linear relationship between the signal heights per unit mass and the applied doses was found; and 4-) The signals were highly stable, with half-time values between 240 and 370 days for 20 and 30 kGy, permitting more than one year of monitoring proceedings. In conclusion, the ESR allows the detection, quantification and time monitoring processes of this kind of irradiated materials. (author) [es

  4. An ESR study of radicals induced in irradiated fresh mango

    International Nuclear Information System (INIS)

    Kikuchi, Masahiro; Hussain, Mohammed S.; Morishita, Norio; Kobayashi, Yasuhiko; Ukai, Mitsuko; Shimoyama, Yuhei

    2009-01-01

    An electron spin resonance (ESR) spectroscopic study was performed on the radicals induced irradiated fresh mangoes. Fresh Philippine mangoes were irradiated by the γ-rays, lyophilized and powdered. The ESR spectrum of the dry specimen showed a strong main peak at g=2.004 and a pair of peaks at both magnetic fields of the main peak. The main peak detected from flesh and skin specimens faded away in a few days after the irradiation. On the other hand, the side peaks showed a well-defined dose response even 9 days after the irradiation. The side-peak is a useful mean to define the irradiation on fresh mangoes. (author)

  5. Investigation of the isochronous mode of the experimental storage ring (ESR) and the collector ring (CR). Decay spectroscopy of highly charged stored 140Pr ions at the FRS-ESR facility

    International Nuclear Information System (INIS)

    Litvinov, Sergey A.

    2008-11-01

    The combination of the present fragment separator FRS and the cooler-storage ring ESR at GSI provides conditions for accurate mass and unique half-life measurements of exotic nuclei. A major part of this doctoral work has been devoted to investigations of the isochronous ion-optical operating mode of the present ESR facility and the planned Collector Ring (CR) facility at FAIR. A detailed ion-optical study of the isochronous storage ring with the emphasis on the main parameters has been done. For example, a simple scaling law providing a quantitative estimate for the mass resolving power as a function of the transverse acceptance has been derived. The ion-optical matching of the FRS-ESR has been calculated and experimentally verified for both the standard and the isochronous operating modes of the ESR. In addition, the dispersion function of a stored ion beam has been measured for both ion-optical modes at the straight section. The improved setting for higher transmission in the standard mode has been used in an experiment on the half-life measurements of highly-charged ions. Orbital electron capture (EC) and/or β + -decay rates of 140 Pr ions with zero-, one- and two- bound electrons have been measured. A complementary future study of EC-decay in highly-charged 64 Cu ions is discussed. Based on the present experience, the ion-optical matching between the future in-flight fragment separator Super-FRS and the CR has been calculated. The isochronous mode of the CR has been calculated. A dedicated Monte-Carlo code (ISOCHRON) has been developed in order to investigate the influence of the transverse acceptance, the closed orbit distortions, the fringe fields of the quadrupoles, the magnetic field imperfections of the magnets on the mass resolving power. The influence of chromaticity on the isochronicity has been investigated. The correction of the chromaticity and of second-order isochronicity has been performed employing sextupole magnets in the arcs of the CR. The

  6. ESR dating of the fault rocks

    International Nuclear Information System (INIS)

    Lee, Hee Kwon

    2005-01-01

    We carried out ESR dating of fault rocks collected near the nuclear reactor. The Upcheon fault zone is exposed close to the Ulzin nuclear reactor. The space-time pattern of fault activity on the Upcheon fault deduced from ESR dating of fault gouge can be summarised as follows : this fault zone was reactivated between fault breccia derived from Cretaceous sandstone and tertiary volcanic sedimentary rocks about 2 Ma, 1.5 Ma and 1 Ma ago. After those movements, the Upcheon fault was reactivated between Cretaceous sandstone and fault breccia zone about 800 ka ago. This fault zone was reactivated again between fault breccia derived form Cretaceous sandstone and Tertiary volcanic sedimentary rocks about 650 ka and after 125 ka ago. These data suggest that the long-term(200-500 k.y.) cyclic fault activity of the Upcheon fault zone continued into the Pleistocene. In the Ulzin area, ESR dates from the NW and EW trend faults range from 800 ka to 600 ka NE and EW trend faults were reactivated about between 200 ka and 300 ka ago. On the other hand, ESR date of the NS trend fault is about 400 ka and 50 ka. Results of this research suggest the fault activity near the Ulzin nuclear reactor fault activity continued into the Pleistocene. One ESR date near the Youngkwang nuclear reactor is 200 ka

  7. ESR signals of irradiated insects

    International Nuclear Information System (INIS)

    Ukai, Mitsuko; Kameya, Hiromi; Imamura, Taro; Miyanoshita, Akihiro; Todoriki, Setsuko; Shimoyama, Yuhei

    2009-01-01

    Analysis of irradiated insects using Electron Spin Resonance (ESR) spectroscopy was reported. The insects were maize weevil, red flour beetle, Indian meal moth and cigarette beetle that are hazardous to crops. The ESR spectra were consisted of a singlet at g=2 and a sextet centered at the similar g-value. The singlet signal is due to an organic free radical. The sextet signal is attributable to the hyperfine interactions from Mn 2+ ions. Upon irradiation, new signals were not detected. The relaxation times, T 1 and T 2 , showed no variations before and after irradiation. (author)

  8. Investigation of the isochronous mode of the experimental storage ring (ESR) and the collector ring (CR). Decay spectroscopy of highly charged stored {sup 140}Pr ions at the FRS-ESR facility

    Energy Technology Data Exchange (ETDEWEB)

    Litvinov, Sergey A.

    2008-11-15

    The combination of the present fragment separator FRS and the cooler-storage ring ESR at GSI provides conditions for accurate mass and unique half-life measurements of exotic nuclei. A major part of this doctoral work has been devoted to investigations of the isochronous ion-optical operating mode of the present ESR facility and the planned Collector Ring (CR) facility at FAIR. A detailed ion-optical study of the isochronous storage ring with the emphasis on the main parameters has been done. For example, a simple scaling law providing a quantitative estimate for the mass resolving power as a function of the transverse acceptance has been derived. The ion-optical matching of the FRS-ESR has been calculated and experimentally verified for both the standard and the isochronous operating modes of the ESR. In addition, the dispersion function of a stored ion beam has been measured for both ion-optical modes at the straight section. The improved setting for higher transmission in the standard mode has been used in an experiment on the half-life measurements of highly-charged ions. Orbital electron capture (EC) and/or {beta}{sup +}-decay rates of {sup 140}Pr ions with zero-, one- and two- bound electrons have been measured. A complementary future study of EC-decay in highly-charged {sup 64}Cu ions is discussed. Based on the present experience, the ion-optical matching between the future in-flight fragment separator Super-FRS and the CR has been calculated. The isochronous mode of the CR has been calculated. A dedicated Monte-Carlo code (ISOCHRON) has been developed in order to investigate the influence of the transverse acceptance, the closed orbit distortions, the fringe fields of the quadrupoles, the magnetic field imperfections of the magnets on the mass resolving power. The influence of chromaticity on the isochronicity has been investigated. The correction of the chromaticity and of second-order isochronicity has been performed employing sextupole magnets in the

  9. Progress in ESR dating of fossils

    International Nuclear Information System (INIS)

    Ikeya, M.

    1983-01-01

    In this review the progress of ESR dating is briefly described together with its historical development. Examples of fossil dating include shells and corals in geological sediments, fossil bones and teeth in anthropology and fossil woods in geology. The total dose of natural radiation (TD) equivalent to the archaeological dose in TL dating was obtained by the additive dose method. Initially, the TDs were plotted against the known ages; using the apparent annual dose-rate thus obtained gives the ESR age within a factor of 2 or 3 for a fossil. Precise assessment of the radiation environment was made later taking the disequilibrium of uranium series disintegration into account. ESR ages of corals agreed well with those obtained by radiocarbon and uranium-thorium methods. The time-independent accumulation rate or a linear accumulation or uranium was adopted as a first sensible model for the opensystem fossil bones: the relation between the TD and the age explains the ages of anthropologically important bones. Lastly, geological assessment of fossil woods was made by ESR based on the organic radicals and electron traps in the silicified part. (author)

  10. Detection of irradiated strawberries by identifying ESR peak of irradiated cellulose component

    International Nuclear Information System (INIS)

    Goto, Michiko; Tanabe, Hiroko

    2002-01-01

    The method of detecting low-dose irradiated strawberries by identifying ESR peak of irradiated cellulose component was studied. Ratio of peak height (S) of high magnetic field cellulose component, and noise width (N) of either irradiated or unirradiated seeds of strawberries were compared. In this study, sample was identified to be irradiated when S/N ratio of ESR spectrum of 4 min. sweep time was above 0.7. In the case of S/N ratio below 0.7, when the S/N ratio of integrated ESR spectrum, obtained from measuring 10 times with 1 min. sweep time was above 1.0, the sample was identified to be irradiated. The result suggests that S/N ratio is a good marker to detect the irradiation. The strawberries irradiated above 0.5kGy was able to be detected after 3 days storage at room temperature, after 21 days refrigeration and after 60 days freezing, respectively. (author)

  11. Association with litter size of new polymorphisms on ESR1 and ESR2 genes in a Chinese-European pig line

    Directory of Open Access Journals (Sweden)

    Rodriguez Carmen

    2007-02-01

    Full Text Available Abstract The objective of this study was to search for polymorphisms in the coding region of the estrogen receptors 1 and 2 (ESR1 and ESR2 and to analyze the effects of these variants and the well known intronic ESR1 Pvu II polymorphism on litter size in a Chinese-European pig line. We identified five silent single nucleotide polymorphisms (SNP in the ESR1 cDNA: c.669T > C (exon 3, c.1227C > T (exon 5, c.1452C > T (exon 7, c.1665T > C and c.1755A > G (exon 8. One pair of these SNP (c.1665T > C and c.1755A > G co-segregated in the analyzed line, and the SNP c.669T > C showed the same segregation pattern as the Pvu II polymorphism. These polymorphisms were tested in this study, although the c.1452C > T SNP within exon 7 was not analyzed due to its low informativeness. In the ESR2 cDNA, one missense SNP was found within exon 5, which caused an amino acid substitution in the coded protein: "c.949G > A (p.Val317Met" and was tested on sow litter size. Information on 1622 litter records from 408 genotyped sows was analyzed to determine whether these SNP influenced the total number of piglets born (TNB or the number of born alive (NBA. The polymorphisms ESR1: [Pvu II; c.669T > C], ESR1: [c.1665T > C; c.1755A > G] and ESR2: c.949G > A showed no statistically significant association with litter size. However, the ESR1: c.1227T allele was significantly associated with TNB. The additive substitution effect was estimated to be 0.40 piglets born per litter (P

  12. Deflection evaluation using time-resolved radiography

    International Nuclear Information System (INIS)

    Fry, D.A.; Lucero, J.P.

    1990-01-01

    Time-resolved radiography is the creation of an x-ray image for which both the start-exposure and stop-exposure times are known with respect to the event under study. The combination of image and timing are used to derive information about the event. The authors have applied time-resolved radiography to evaluate motions of explosive-driven events. In the particular application discussed in this paper, the author's intent is to measure maximum deflections of the components involved. Exposures are made during the time just before to just after the event of interest occurs. A smear or blur of motion out to its furthest extent is recorded on the image. Comparison of the dynamic images with static images allows deflection measurements to be made

  13. An ESR study of defects in irradiated hydroxyapatite

    International Nuclear Information System (INIS)

    Murata, T.; Shiraishi, K.; Ebina, Y.; Miki, T.

    1996-01-01

    Radiation-induced defects in synthetic hydroxyapatite (HAp) of six different origins have been investigated by electron spin resonance (ESR), X-ray diffraction (XRD), Raman scattering and IR measurements. The orthorhombic CO 2 - radicals were detected in almost all of the samples examined, but the isotropic CO 2 - was produced only in water-containing HAp with low crystallinity. The doublet signal due to H 0 was clearly detected in HAp with extreme calcium deficiency as compared to the stoichiometry. The results of ESR and FTIR suggest that water molecules in low crystalline HAp are not on the surface but embedded in the HAp crystalline lattice. (author)

  14. Dual time-resolved temperature-jump fluorescence and infrared spectroscopy for the study of fast protein dynamics.

    Science.gov (United States)

    Davis, Caitlin M; Reddish, Michael J; Dyer, R Brian

    2017-05-05

    Time-resolved temperature-jump (T-jump) coupled with fluorescence and infrared (IR) spectroscopy is a powerful technique for monitoring protein dynamics. Although IR spectroscopy of the polypeptide amide I mode is more technically challenging, it offers complementary information because it directly probes changes in the protein backbone, whereas, fluorescence spectroscopy is sensitive to the environment of specific side chains. With the advent of widely tunable quantum cascade lasers (QCL) it is possible to efficiently probe multiple IR frequencies with high sensitivity and reproducibility. Here we describe a dual time-resolved T-jump fluorescence and IR spectrometer and its application to study protein folding dynamics. A Q-switched Ho:YAG laser provides the T-jump source for both time-resolved IR and fluorescence spectroscopy, which are probed by a QCL and Ti:Sapphire laser, respectively. The Ho:YAG laser simultaneously pumps the time-resolved IR and fluorescence spectrometers. The instrument has high sensitivity, with an IR absorbance detection limit of jump induced difference spectrum from 50ns to 0.5ms. This study demonstrates the power of the dual time-resolved T-jump fluorescence and IR spectroscopy to resolve complex folding mechanisms by complementary IR absorbance and fluorescence measurements of protein dynamics. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. ESR measurements and the detection of radiosterilization of drugs

    International Nuclear Information System (INIS)

    Gibella, M.; Crucq, A.S.; Tilquin, B.

    1993-01-01

    The ESR spectrum of trapped radicals in irradiated solid antibiotics could permit the detection of the radiosterilization. The ESR signal is detected only after radiolysis; at room temperature, this ESR spectrum is observable for a few hours or until several years. The rate of the metathesis reactions can be fast or very slow, the reaction path is unknown,. However, in many cases, the polycrystalline solid phase exhibits its ability to keep radicals for a long period of time and the detection of the radiolysis is possible during this period. 10 figs., 1 tab

  16. Time-resolved emission from laser-ablated uranium

    International Nuclear Information System (INIS)

    Stoffels, E.; Mullen, J. van der; Weijer, P. van de

    1991-01-01

    Time-resolved emission spectra from the plasma, induced by laser ablation of uranium samples have been studied. The dependence of the emission intensity on time is strongly affected by the nature and pressure of the buffer gas. Air and argon have been used in the pressure range 0.002 to 5 mbar. The emission intensity as a function of time displays three maxima, indicating that three different processes within the expanding plasma plume are involved. On basis of the time-resolved spectra we propose a model that explains qualitatively the phenomena that are responsible for this time behaviour. (author)

  17. A novel multiplex absorption spectrometer for time-resolved studies

    Science.gov (United States)

    Lewis, Thomas; Heard, Dwayne E.; Blitz, Mark A.

    2018-02-01

    A Time-Resolved Ultraviolet/Visible (UV/Vis) Absorption Spectrometer (TRUVAS) has been developed that can simultaneously monitor absorption at all wavelengths between 200 and 800 nm with millisecond time resolution. A pulsed photolysis laser (KrF 248 nm) is used to initiate chemical reactions that create the target species. The absorption signals from these species evolve as the composition of the gas in the photolysis region changes over time. The instrument can operate at pressures over the range ˜10-800 Torr and can measure time-resolved absorbances systems (in particular the Herriott cell), there are fundamental differences, most notably the ability to adjust each mirror to maximise the overlap between the probe beam and the photolysis laser. Another feature which aids the sensitivity and versatility of the system is the use of 2 high-throughput spectrographs coupled with sensitive line-array CCDs, which can measure absorbance from ˜200 to 800 nm simultaneously. The capability of the instrument is demonstrated via measurements of the absorption spectrum of the peroxy radical, HOCH2CH2O2, and its self-reaction kinetics.

  18. Analysis of ESR measurement parameters for detecting irradiated spices

    International Nuclear Information System (INIS)

    Kameya, Hiromi; Hagiwara, Shoji; Todoriki, Setsuko

    2015-01-01

    The side signals from irradiated cellulose radical are used for detecting irradiated spices with the electron spin resonance (ESR). The side signals are two signals observed on both sides of a singlet signal (g≒2.00) from organic free radicals. Since the intensities of the side signals are weak, if the width of the singlet signal is large, these signals are covered and cannot be observed. In this study, we analyzed ESR measurement parameters of seven kinds spices (oregano, basil, parsley, coriander, cumin, white pepper, and black pepper) that would lead to narrow width of the singlet signal for detecting side signals. The results were as follows: 4 mW microwave power for basil, parsley, oregano, coriander, and cumin, and 8 mW for white pepper and black pepper, while modulation amplitude of 4 G, time constant of 20 ms were determined to be the optimal ESR measurement parameters. (author)

  19. Combined ESR and U-series isochron dating of fossil tooth from Longgupo cave

    International Nuclear Information System (INIS)

    Han Fei; Yin Gongming; Liu Chunru; Jean-Jacques Bahain

    2012-01-01

    Background: In ESR and luminescence archaeological dating, the assessment of external radiation dose rate is one of the constant sources of uncertainty because of its variation in the past time and it cannot be determined accurately using the present-day measurements. Purpose: ESR isochron protocol was proposed to solve this uncertainty for the tooth samples. This protocol is applicable wherever multiple samples with different internal doses have all experienced a common external dose. The variable uranium concentration of tooth samples makes it possible to plot the equivalent dose versus the internal dose rate of each sample, and the slope of isochron line gives hence the age. For isochron dating of teeth, combined ESR/U-series dating analysis must be done together with isochron protocol. Methods: In this study, we try to use combined ESR/U-series isochron method on 5 tooth samples collected from immediate adjacent square in layer C Ⅲ'6 of Longgupo archaeological site, Chongqing, China. Combined ESR/U-series analysis with in situ external dose rate shows recent uranium uptake of all the samples. Results: The time-averaged external dose rate was iterative calculated by isochron protocol, and gives an isochron age of 1.77±0.09 Ma for layer C Ⅲ'6, which consistent with the mean US-ESR ages of 5 samples (1.64+0.16/-0.21 Ma) in the error range. The calculated time-averaged external dose rate(∼807 μGy/a) was basically in agreement with the in situ measured gamma dose rate value (8.50 μGy/a) in 2006, indicating the geochemical alterations may not occurred or do not affect the environmental dose rate obviously during the burial history. Conclusions: This study indicates the potential of solving both internal and external dose rate problems of ESR dating of fossil teeth by combining with U-series analysis and isochron protocol. (authors)

  20. Time-resolved hard x-ray studies using third-generation synchrotron radiation sources (abstract)

    International Nuclear Information System (INIS)

    Mills, D.M.

    1992-01-01

    The third-generation, high-brilliance, synchrotron radiation sources currently under construction will usher in a new era of x-ray research in the physical, chemical, and biological sciences. One of the most exciting areas of experimentation will be the extension of static x-ray scattering and diffraction techniques to the study of transient or time-evolving systems. The high repetition rate, short-pulse duration, high-brilliance, variable spectral bandwidth, and large particle beam energies of these sources make them ideal for hard x-ray, time-resolved studies. The primary focus of this presentation will be on the novel instrumentation required for time-resolved studies such as optics which can increase the flux on the sample or disperse the x-ray beam, detectors and electronics for parallel data collection, and methods for altering the natural time structure of the radiation. This work is supported by the U.S. Department of Energy, BES-Materials Science, under Contract No. W-31-109-ENG-38

  1. Time-resolved absorption measurements on OMEGA

    International Nuclear Information System (INIS)

    Jaanimagi, P.A.; DaSilva, L.; Delettrez, J.; Gregory, G.G.; Richardson, M.C.

    1986-01-01

    Time-resolved measurements of the incident laser light that is scattered and/or refracted from targets irradiated by the 24 uv-beam OMEGA laser at LLE, have provided some interesting features related to time-resolved absorption. The decrease in laser absorption characteristic of irradiating a target that implodes during the laser pulse has been observed. The increase in absorption expected as the critical density surface moves from a low to a high Z material in the target has also been noted. The detailed interpretation of these results is made through comparisons with simulation using the code LILAC, as well as with streak data from time-resolved x-ray imaging and spectroscopy. In addition, time and space-resolved imaging of the scattered light yields information on laser irradiation uniformity conditions on the target. The report consists of viewgraphs

  2. [Identification of irradiated abalone by ESR spectroscopy].

    Science.gov (United States)

    Song, Yeping; Wang, Chuanxian; Yang, Zhenyu; Zhong, Weike; Geng, Jinpei; Lu, Di; Ding, Zhuoping

    2012-05-01

    To establish an analytical method for the detection and identification of irradiated abalone by electron spin resonance spectroscopy. Electron spin resonance (ESR) was used to study the spectral characteristics of abalone and the characteristic peak for quantitation. There were obvious different ESR spectra between unirradiated and irradiated abalone. The g factor for unirradiated abalone was 2.0055-2.0060, the g1 and g2 factor for irradiated abalone were (2.0027 +/- 0.0001) and (1.9994 +/- 0.0001), respectively. The ESR signal intensity of characteristic peak was positively correlated with absorbed dose in the range of 0.5 - 10 kGy, left peak was the characteristic peak for quantitation and the detection limit was abalone. ESR spectroscopy is an effective method to determine whether the abalone being irradiated or not.

  3. Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources

    International Nuclear Information System (INIS)

    Rutherford, Michael E.; Chapman, David J.; White, Thomas G.; Drakopoulos, Michael; Rack, Alexander; Eakins, Daniel E.

    2016-01-01

    Scintillator performance in time-resolved, hard, indirect detection X-ray studies on the sub-microsecond timescale at synchrotron light sources is reviewed, modelled and examined experimentally. LYSO:Ce is found to be the only commercially available crystal suitable for these experiments. The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is targeted at two-dimensional integrating detector methods, such as those focused on dynamic radiography and diffraction experiments. The response of a scintillator to periodic synchrotron X-ray excitation is modelled and validated against experimental data collected at the Diamond Light Source (DLS) and European Synchrotron Radiation Facility (ESRF). An upper bound on the dynamic range accessible in a time-resolved experiment for a given bunch separation is calculated for a range of scintillators. New bunch structures are suggested for DLS and ESRF using the highest-performing commercially available crystal LYSO:Ce, allowing time-resolved experiments with an interframe time of 189 ns and a maximum dynamic range of 98 (6.6 bits)

  4. Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources

    Energy Technology Data Exchange (ETDEWEB)

    Rutherford, Michael E.; Chapman, David J.; White, Thomas G. [Imperial College London, London (United Kingdom); Drakopoulos, Michael [Diamond Light Source, I12 Joint Engineering, Environmental, Processing (JEEP) Beamline, Didcot, Oxfordshire (United Kingdom); Rack, Alexander [European Synchrotron Radiation Facility, Grenoble (France); Eakins, Daniel E., E-mail: d.eakins@imperial.ac.uk [Imperial College London, London (United Kingdom)

    2016-03-24

    Scintillator performance in time-resolved, hard, indirect detection X-ray studies on the sub-microsecond timescale at synchrotron light sources is reviewed, modelled and examined experimentally. LYSO:Ce is found to be the only commercially available crystal suitable for these experiments. The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is targeted at two-dimensional integrating detector methods, such as those focused on dynamic radiography and diffraction experiments. The response of a scintillator to periodic synchrotron X-ray excitation is modelled and validated against experimental data collected at the Diamond Light Source (DLS) and European Synchrotron Radiation Facility (ESRF). An upper bound on the dynamic range accessible in a time-resolved experiment for a given bunch separation is calculated for a range of scintillators. New bunch structures are suggested for DLS and ESRF using the highest-performing commercially available crystal LYSO:Ce, allowing time-resolved experiments with an interframe time of 189 ns and a maximum dynamic range of 98 (6.6 bits)

  5. Time-resolved resonance Raman spectroscopy of radiation-chemical processes

    International Nuclear Information System (INIS)

    Tripathi, G.N.R.

    1983-01-01

    A tunable pulsed laser Raman spectrometer for time resolved Raman studies of radiation-chemical processes is described. This apparatus utilizes the state of art optical multichannel detection and analysis techniques for data acquisition and electron pulse radiolysis for initiating the reactions. By using this technique the resonance Raman spectra of intermediates with absorption spectra in the 248-900 nm region, and mean lifetimes > 30 ns can be examined. This apparatus can be used to time resolve the vibrational spectral overlap between transients absorbing in the same region, and to follow their decay kinetics by monitoring the well resolved Raman peaks. For kinetic measurements at millisecond time scale, the Raman technique is preferable over optical absorption method where low frequency noise is quite bothersome. A time resolved Raman study of the pulse radiolytic oxidation of aqueous tetrafluorohydroquinone and p-methoxyphenol is briefly discussed. 15 references, 5 figures

  6. Relationship between time-resolved and non-time-resolved Beer-Lambert law in turbid media.

    Science.gov (United States)

    Nomura, Y; Hazeki, O; Tamura, M

    1997-06-01

    The time-resolved Beer-Lambert law proposed for oxygen monitoring using pulsed light was extended to the non-time-resolved case in a scattered medium such as living tissues with continuous illumination. The time-resolved Beer-Lambert law was valid for the phantom model and living tissues in the visible and near-infrared regions. The absolute concentration and oxygen saturation of haemoglobin in rat brain and thigh muscle could be determined. The temporal profile of rat brain was reproduced by Monte Carlo simulation. When the temporal profiles of rat brain under different oxygenation states were integrated with time, the absorbance difference was linearly related to changes in the absorption coefficient. When the simulated profiles were integrated, there was a linear relationship within the absorption coefficient which was predicted for fractional inspiratory oxygen concentration from 10 to 100% and, in the case beyond the range of the absorption coefficient, the deviation from linearity was slight. We concluded that an optical pathlength which is independent of changes in the absorption coefficient is a good approximation for near-infrared oxygen monitoring.

  7. Time-resolved terahertz spectroscopy of semiconductor nanostructures

    DEFF Research Database (Denmark)

    Porte, Henrik

    This thesis describes time-resolved terahertz spectroscopy measurements on various semiconductor nanostructures. The aim is to study the carrier dynamics in these nanostructures on a picosecond timescale. In a typical experiment carriers are excited with a visible or near-infrared pulse and by me......This thesis describes time-resolved terahertz spectroscopy measurements on various semiconductor nanostructures. The aim is to study the carrier dynamics in these nanostructures on a picosecond timescale. In a typical experiment carriers are excited with a visible or near-infrared pulse...... and by measuring the transmission of a terahertz probe pulse, the photoconductivity of the excited sample can be obtained. By changing the relative arrival time at the sample between the pump and the probe pulse, the photoconductivity dynamics can be studied on a picosecond timescale. The rst studied semiconductor...

  8. ESR Study of the polyvinyl alcohol gamma-ray induced free-radicals

    International Nuclear Information System (INIS)

    Rosas S, E.

    1994-01-01

    This work reports the findings of the molecular weight effect on the electron spin resonance saturation curve of the gamma-ray irradiated polyvinyl alcohol, G-RIPVA. It has been noted that Pva of a lower molecular weight, between 13,000-23,000, show some noticeable differences in the electron spin resonance, ESR, response as a function of the gamma-ray dose in the 1-100 k Gy range than the one reported in the literature with molecular weight of 108,000. Results show a linear response in the log-log plot of the dose vs ESR signal intensity for samples based on G-RIPVA of the lower molecular weight as contrasted with the non-linear ESR response of G-RIPVA of higher molecular weight in the above named dose range. Such a result has been assumed to arise from the shorter molecular chains for the case of the lower molecular weight samples making this to increase the production of Pva free radicals with respect to the absorbed studied doses. Also, a discussion on the nature and stability of the Pva free radicals will be given. (Author)

  9. ESR Study of PE, HDPE and UHMWPE Irradiated with Ion Beams and Neutrons

    International Nuclear Information System (INIS)

    Reyes-Romero, J.

    2006-01-01

    We report the Electron Spin Resonance (RES) studies on the effects produced by bombarding with accelerated Sulfur ions, Protons and Neutrons on the Polyethylene, PE, (Hostalen and Romanian), ultra-high molecular weight polyethylene, UHMWPE, ( GUR 1050, medical grade Lennite), and high density polyethylene, HDPE, (HDPE-7000F, Polinter de Venezuela, PDVSA). The resonance spectra have been recorded using a Varian E-line-X ESR spectrometer at 100 KHz modulation frequency. In thin films of Polyethylene (Hostalen and UHMWPE) have been irradiated with Sulfur ions, S, accelerated at about 7 MeV/nucleons, and Protons at about 5 MeV/nucleons (IFIN, Romania). Samples of Polyethylene ( HDPE 7000-F) were irradiate with neutrons from a Pu-Be source (flux of 1.19 x 10 6 n/s. cm 2 , 5.65 MeV, IVIC, Venezuela) from 0 to 8 hours in the presence of air and at room temperature (RT). The ESR measurements were performed after a storage time of about 7 months, in air at room temperature. The nature of the free radicals induced by irradiation as well as the dependence of resonance line, resonance line shape and radicals concentration has been studied

  10. ESR identification of irradiated foodstuffs: LARQUA research

    Energy Technology Data Exchange (ETDEWEB)

    Raffi, J [Laboratoire de Recherche sur la Qualite des Aliments, Marseille (France)

    1997-12-31

    As electron spin resonance (ESR) spectroscopy is the leading method for identification of irradiated foodstuffs, meat and fish bones, fruit and relative products (of vegetable origin), sea-food etc. were studied. In order to prepare a large co-trial on ESR identification of irradiation of irradiated foodstuffs, experiments were carried out at LARQUA, especially on fruits and vegetables. The radicals induced in the fruit pulp are not stable because the water content of fruit is generally high, but ESR can be used with dried fruit or dry components such as achenes, pips or stones. Different responses are observed, depending on the fruit. In ``sugatype`` fruits (papaya, dried grapes), an ESR multicomponent signal is radio-induced, but the non-irradiated fruit presents no ESR signal or a single-line, while in ``cellulose type`` fruits (pistachio nut, berries), a triplet is induced. But a six line signal due to Mn{sup 2+} and a central single line may also be present both in irradiated and non-irradiated samples. In the case of aromatic herbs, the proposed official CEN protocol for irradiated food containing cellulose was used. (author).

  11. ESR identification of irradiated foodstuffs: LARQUA research

    International Nuclear Information System (INIS)

    Raffi, J.

    1996-01-01

    As electron spin resonance (ESR) spectroscopy is the leading method for identification of irradiated foodstuffs, meat and fish bones, fruit and relative products (of vegetable origin), sea-food etc. were studied. In order to prepare a large co-trial on ESR identification of irradiation of irradiated foodstuffs, experiments were carried out at LARQUA, especially on fruits and vegetables. The radicals induced in the fruit pulp are not stable because the water content of fruit is generally high, but ESR can be used with dried fruit or dry components such as achenes, pips or stones. Different responses are observed, depending on the fruit. In ''sugatype'' fruits (papaya, dried grapes), an ESR multicomponent signal is radio-induced, but the non-irradiated fruit presents no ESR signal or a single-line, while in ''cellulose type'' fruits (pistachio nut, berries), a triplet is induced. But a six line signal due to Mn 2+ and a central single line may also be present both in irradiated and non-irradiated samples. In the case of aromatic herbs, the proposed official CEN protocol for irradiated food containing cellulose was used. (author)

  12. Investigation of radiosterilization feasibility of sulfamethoxazole by ESR spectroscopy

    Science.gov (United States)

    Çolak, Şeyda

    2017-12-01

    In the present study, the spectroscopic features of the radiolytic intermediates that were produced in gamma-irradiated (5, 10, 25 and 50 kGy) sulfamethoxazole (SMX) have been investigated by electron spin resonance (ESR) spectroscopy and the radiation sterilization feasibility of SMX by ionizing radiation was examined. Gamma-irradiated SMX exhibited a complex ESR spectrum consisting of 13 resonance lines where spectral parameters for the central resonance line were found to be g = 2.0062 and ΔHpp = 0.6 mT. The radiation yield of SMX was calculated to be relatively low (G = 0.1) by ESR spectroscopy and no meaningful difference was observed in the comparison of unirradiated and 50 kGy gamma irradiated SMX by the Fourier transform infrared (FT-IR) technique, confirming that SMX is a radioresistive material. Although SMX could not be accepted to be a good dosimetric material, the identification of irradiated SMX from the unirradiated sample was possible even for the low absorbed radiation doses and for a relatively long time (three months) after the irradiation process. Decay activation energy of the radical species, which is mostly responsible for the central intense resonance line, is calculated to be 45.15 kJ/mol by using the signal intensity decay data derived from annealing studies. Four radical species with different spectroscopic properties were accepted to be responsible for the ESR spectra of gamma-irradiated SMX, by simulation calculations. It is concluded that SMX and SMX-containing drugs can be sterilized by gamma radiation and ESR spectroscopy is an appropriate technique for the characterization of these induced radical intermediates during the gamma irradiation process of SMX. Toxicology tests should also be done for its safe usage.

  13. Time-resolved photoelectron spectroscopy and ab initio multiple spawning studies of hexamethylcyclopentadiene

    DEFF Research Database (Denmark)

    Wolf, T. J. A.; Kuhlman, Thomas Scheby; Schalk, O.

    2014-01-01

    Time-resolved photoelectron spectroscopy and ab initio multiple spawning were applied to the ultrafast non-adiabatic dynamics of hexamethylcyclopentadiene. The high level of agreement between experiment and theory associates wavepacket motion with a distinct degree of freedom.......Time-resolved photoelectron spectroscopy and ab initio multiple spawning were applied to the ultrafast non-adiabatic dynamics of hexamethylcyclopentadiene. The high level of agreement between experiment and theory associates wavepacket motion with a distinct degree of freedom....

  14. Time-resolved resonance fluorescence spectroscopy for study of chemical reactions in laser-induced plasmas.

    Science.gov (United States)

    Liu, Lei; Deng, Leimin; Fan, Lisha; Huang, Xi; Lu, Yao; Shen, Xiaokang; Jiang, Lan; Silvain, Jean-François; Lu, Yongfeng

    2017-10-30

    Identification of chemical intermediates and study of chemical reaction pathways and mechanisms in laser-induced plasmas are important for laser-ablated applications. Laser-induced breakdown spectroscopy (LIBS), as a promising spectroscopic technique, is efficient for elemental analyses but can only provide limited information about chemical products in laser-induced plasmas. In this work, time-resolved resonance fluorescence spectroscopy was studied as a promising tool for the study of chemical reactions in laser-induced plasmas. Resonance fluorescence excitation of diatomic aluminum monoxide (AlO) and triatomic dialuminum monoxide (Al 2 O) was used to identify these chemical intermediates. Time-resolved fluorescence spectra of AlO and Al 2 O were used to observe the temporal evolution in laser-induced Al plasmas and to study their formation in the Al-O 2 chemistry in air.

  15. Electron Spin Resonance (ESR) studies of returned comet nucleus samples

    International Nuclear Information System (INIS)

    Tsay, Fundow; Kim, S.S.; Liang, R.H.

    1989-01-01

    The most important objective of the Comet Nucleus Sample Returm Mission is to return samples which could reflect formation conditions and evolutionary processes in the early solar nebula. It is expected that the returned samples will consist of fine-grained silicate materials mixed with ices composed of simple molecules such as H 2 O, NH 3 , CH 4 as well as organics and/or more complex compounds. Because of the exposure to ionizing radiation from cosmic-ray, gamma-ray, and solar wind protons at low temperature, free radicals are expected to be formed and trapped in the solid ice matrices. The kind of trapped radical species together with their concentration and thermal stability can be used as a dosimeter as well as a geothermometer to determine thermal and radiation histories as well as outgassing and other possible alternation effects since the nucleus material was formed. Since free radicals that are known to contain unpaired electrons are all paramagnetic in nature, they can be readily detected and characterized in their native form by the Electron Spin Resonance (ESR) method. In fact, ESR has been shown to be a non-destructive, highly sensitive tool for the detection and characterization of paramagnetic, ferromagnetic, and radiation damage centers in terrestrial and extraterrestrial geological samples. The potential use of ESR as an effective method in the study of returned comet nucleus samples, in particular, in the analysis of fine-grained solid state icy samples is discussed

  16. ESR study of advanced materials with new parameters frequency and pressure

    CERN Document Server

    Mizoguchi, K

    2000-01-01

    It is well known that electron spin resonance (ESR) is a useful technique to investigate the magnetic properties of electrons in condensed matter. The frequency, as an additional parameter to the temperature, gives us the possibility to study the anisotropic dynamics of charge carriers with spin, even in polycrystalline materials. Furthermore, the pressure provides us a way to discuss how interactions between the electrons and their environments are responsible for the novel physical properties in these advanced materials, such as ferromagnetisms, charge-density waves, superconductivity, and so on. Results obtained by using ESR with these parameters are overviewed. Studies as a function of the frequency are demonstrated, especially for the conductive polymers, polyacetylene, polyaniline, and polypyrrole with various dopants for which single crystals are not available yet. Alkali-electro-sodalite (AES), a kind of zeolite with a regular electron lattice known as an s-electron Mott insulator, and fullerene compo...

  17. Radicals in DNA as seen by ESR spectroscopy

    International Nuclear Information System (INIS)

    Symons, M.C.R.

    1997-01-01

    This is a review of ESR studies, mainly of DNA systems, after exposure to ionising radiation at low temperatures. Under this conditions 'direct' damage is of major significance, and ESR evidence for the concept of the initial formation of electron-gain and electron-loss centers localised within DNA bases, and deeply trapped by proton-gain and loss, will be discussed. It is stressed that 'negative' evidence, showing that various phosphate and sugar centred radicals are not detected, is of major importance since the ESR 'fingerprints' of base-radicals are relatively ill defined. (author)

  18. ESR studies of heat denaturation in Cu myoglobin complexes

    International Nuclear Information System (INIS)

    Louro, S.R.W.; Ribeiro, S.C.; Bemski, G.

    1975-01-01

    An investigation is made on the behaviour of Cu2 + and Fe3 + in copper doped myoglobin, subjected to heat treatment. ESR is observed at X-band. The amplitude of the g = 5.9 line of the high spin F 3 + in met-myoglobin is studied as a function of the temperature of the heat treatment, the pH and the length of time of exposure to the heat treatment. These experiments are performed for both the pure protein and for the copper-myoglobin complex, at pH between 5 and 8.5. Results concerning the decrease of the amplitude of Fe 3+ high spin signal are discussed in comparison with Hollocher's results in hemoglobin. The Cu spectra obtained are interpreted, with the aid of a computer program, Kivelson and Neiman's results being used to analyse the authors data

  19. Correlation of ESR with lyoluminescence dosimetry using some sugars

    International Nuclear Information System (INIS)

    Azorin, Juan; Gutierrez, Alicia; Munoz, Eduardo; Gleason, Roberto

    1989-01-01

    Most applications involving ESR dosimetry currently center on aminoacids because of their relative tissue equivalence. Sugars, however, in addition to possessing high sensitivity and stability in their ESR and LL responses, are widely available as chemical reagents and as commercial sugar. In the present study, dosimetric characteristics of mannose, trehalose, sucrose and commercial sugar obtained by means of ESR and LL techniques are reported. Doses measured by both methods showed agreement within 5%. (author)

  20. Oxygen diffusion-concentration in phospholipidic model membranes. An ESR-saturation study

    International Nuclear Information System (INIS)

    Vachon, A.; Lecomte, C.; Berleur, F.

    1986-04-01

    Fully hydrated liposomes of dipalmitoyl-phosphatidylcholine were labelled with 5 (or 7, 10, 12, 16)-doxyl stearic acid at pH 6 and 8, and studied by the continuous wave ESR-saturation technique. The ESR spectral magnitude depends on the hyperfrequency power P and on both T 1 and T 2 relaxation times. Saturation, i.e. the non linearity of the spectral magnitude plotted versus √P can be quantified by a P1/2 parameter (power at which the signal is half as great as it would be without saturation). If we assume T 2 weakly modified by spin exchange between paramagnetic spin probe and oxygen in triplet state, P1/2 is inversely proportional to T 1 , and becomes a sensitive parameter to appreciate the oxygen transport (oxygen diffusion-concentration product) inside the bilayers. According to the DPPC bilayer phase transition diagrams, P1/2 (oxygen diffusion-concentration) is related to the thermodynamic state of the membrane. This technique provides further informations on a particular property of a radioprotective agent, cysteamine, which seems to inhibit spin-triplet exchange and hence maximizes T 1 (minimizes P1/2). Since radioprotective agents are known to act by scavenging radiation-induced free radicals and by inhibiting oxygen-dependent free radical processes, such a result may contribute to elucidate radioprotecting mechanisms

  1. IAEA reference dosimeter: Alanine-ESR

    International Nuclear Information System (INIS)

    Mehta, K.; Girzikowsky, R.

    1999-01-01

    Since 1985, the IAEA has been using alanine-ESR as a transfer dosimeter for its dose quality audit service, namely the International Dose Assurance Service. The alanine dosimeters are rod-type containing 70 wt% DL--α-alanine and 30 wt% polystyrene. We have two self-shielded gamma facilities for the calibration of the dosimetry system, where the temperature within the irradiation chamber can be controlled by a specially designed unit. A 4th order polynomial is fitted to the 16 data points in the dose range of 100 Gy to 50 kGy. The measured value of the irradiation temperature coefficient at two dose values (15 and 45 kGy) is 0.23 %/deg. C. Also, the ESR-response was followed for several dosimeters for about 8 months to study the post-irradiation effect. A value of 0.008 %/day was observed for the fading of the response for two dose values (15 and 45 kGy) and three irradiation temperatures (15, 27 and 40 deg. C). The effect of the analysis temperature on the ESR response was also studied. The combined relative uncertainty for the IAEA alanine-ESR dosimetry system is 1.5% (k=1). This includes that transferred from the primary laboratory for the dose rate measurements of the gamma facilities, dosimetry system calibration uncertainties, batch variability and uncertainty in the curve fitting procedure. This value however does not include the contribution due to the irradiation temperature correction which is applied when it differs from that during calibration; this component being specific for each dose measurement. (author)

  2. Seventh international conference on time-resolved vibrational spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, R.B.; Martinez, M.A.D.; Shreve, A.; Woodruff, W.H. [comps.

    1997-04-01

    The International Conference on Time-Resolved Vibrational Spectroscopy (TRVS) is widely recognized as the major international forum for the discussion of advances in this rapidly growing field. The 1995 conference was the seventh in a series that began at Lake Placid, New York, 1982. Santa Fe, New Mexico, was the site of the Seventh International Conference on Time-Resolved Vibrational Spectroscopy, held from June 11 to 16, 1995. TRVS-7 was attended by 157 participants from 16 countries and 85 institutions, and research ranging across the full breadth of the field of time-resolved vibrational spectroscopy was presented. Advances in both experimental capabilities for time-resolved vibrational measurements and in theoretical descriptions of time-resolved vibrational methods continue to occur, and several sessions of the conference were devoted to discussion of these advances and the associated new directions in TRVS. Continuing the interdisciplinary tradition of the TRVS meetings, applications of time-resolved vibrational methods to problems in physics, biology, materials science, and chemistry comprised a large portion of the papers presented at the conference.

  3. ESR dating: is it still an 'experimental' technique?

    International Nuclear Information System (INIS)

    Skinner, A.R.

    2000-01-01

    Nearly 25 years ago, Motoji Ikeya demonstrated the potential of ESR dating. From a single substance (stalagmitic carbonate) and a single site (Akiyoshi Cavern), the field has grown to include materials from all over the world and time periods from a few thousand years ago to several million years ago. A vigorous program of instrumentation development has increased the precision of measurements as well as opening up new ways of collecting and interpreting spectra. Yet there are still references to ESR dating as an 'experimental' technique, one which cannot be trusted to produce dates that are accurate or precise. This paper discusses areas for which this is true and suggests what should be done to convince skeptics. Other areas for which the evidence suggests that ESR is at least as reliable as 'standard' methods will also be covered

  4. ESR in a disordered network of nanographene sheets

    Science.gov (United States)

    Hagiwara, M.; Tsugeno, H.; Yamaguchi, H.; Joly, V. L. J.; Takai, K.; Enoki, T.

    2011-12-01

    Randomly networked nanographene sheets have been studied by electron spin resonance (ESR) technique at 20 GHz (K-band) and 35 GHz (Q-band). Nanographene has spin-polarized non-bonding π-electron states (edge-state spins) localized in the zigzag edge region. We have investigated the temperature dependence of an ESR signal of activated carbon fibers at two different microwave powers for each frequency. The signal intensity smoothly increases with decreasing temperature at any microwave power. The line width of ESR signal with a Lorentzian line shape decreases linearly upon cooling, and then increases steeply after taking a minimum at about 20 K irrespective of microwave power. The former is interpreted as the Korringa relation in the localized edge spins and conduction π carriers. The latter may be caused by inhomogeneous line broadening of the ESR signal from randomly distributed nanographene sheets with different sizes due to the suppression of electron hopping between nanographene sheets, i.e. electron localization. The discontinuous line broadening and the signal intensity drop at around 20 K reported in the previous X-band ESR at 1 μW were not observed, probably because of either higher microwave power than 1 μW or some amount of oxygen adsorption in our sample in the present study.

  5. ESR studies of the radiation effects on polystyrene

    International Nuclear Information System (INIS)

    Garrett, R.W.; O'Donnell, J.H.; Pomery, P.J.

    1976-01-01

    The aim of this work was to investigate the polystyrene system (both pure and commercial samples) to elucidate the type and percentage of each paramagnetic species upon exposure to various irradiation doses. The size of dose plays a vital role in the type of spectra obtained. Upon irradiation in vacuo, polystyrene displays ESR spectra which are basically triplet in character but the line spacing and intensities of components are observed to depend on the magnitude of the irradiation dose. G value for the total radicals present and for the individual species present as a function of dose have been obtained. The relative concentration of each paramagnetic species has been determined through computer simulation of the observed ESR spectra. The relative stability of the different species with respect to temperature is discussed. The results for deuterated polystyrene is used to support those obtained for the unsubstituted polystyrene system. (author)

  6. ESR study on free radicals trapped in crosslinked polytetrafluoroethylene (PTFE)

    International Nuclear Information System (INIS)

    Oshima, Akihiro; Tabata, Yoneho; Seguchi, Tadao

    1997-01-01

    Free radicals in crosslinked PTFE which formed by 60 Co γ-rays irradiation at 77 K and at room temperature were studied by electron spin resonance (ESR) spectroscopy. The crosslinked PTFE specimens with different crosslinking density were prepared by electron beam irradiation in the molten state. The ESR spectra observed in the irradiated crosslinked PTFE are much different from those in non-crosslinked PTFE (virgin); a broad singlet component increases with increasing the crosslinking density, G-value of radicals is much higher in crosslinked PTFE than in non-crosslinked one. Free radicals related to the broad component are trapped in the non-crystalline region of crosslinked PTFE and rather stable at room temperature, whereas radicals trapped in amorphous non-crosslinked PTFE are unstable at room temperature. It is thought that most of free radicals trapped in the crosslinked PTFE are formed in the crosslinked amorphous region. The trapped radicals decays around 383 K (110 o C) due to the molecular motion of α-relaxation. (Author)

  7. ESR spectroscopy for detecting gamma-irradiated dried vegetables and estimating absorbed doses

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Joong-Ho; Chung, Hyung-Wook; Byun, Myung-Woo

    2000-03-01

    In view of an increasing demand for food irradiation technology, the development of a reliable means of detection for the control of irradiated foods has become necessary. Various vegetable food materials (dried cabbage, carrot, chunggyungchae, garlic, onion, and green onion), which can be legally irradiated in Korea, were subjected to a detection study using ESR spectroscopy. Correlation coefficients (R{sup 2}) between absorbed doses (2.5-15 kGy) and their corresponding ESR signals were identified from ESR signals. Pre-established threshold values were successfully applied to the detection of 54 coded unknown samples of dried clean vegetables (chunggyungchae, Brassica camestris var. chinensis), both non-irradiated and irradiated. The ESR signals of irradiated chunggyungchae decreased over a longer storage time, however, even after 6 months of ambient storage, these signals were still distinguishable from those of non-irradiated samples. The most successful estimates of absorbed dose (5 and 8 kGy) were obtained immediately after irradiation using a quadratic fit with average values of 4.85 and 8.65 kGy being calculated. (author)

  8. Microstructure Characterization and Corrosion Resistance Behavior of New Cobalt-Free Maraging Steel Produced Through ESR Techniques

    Science.gov (United States)

    Seikh, Asiful H.; Halfa, Hossam; Baig, Muneer; Khan, Sohail M. A.

    2017-04-01

    In this study, two different grades (M23 and M29) of cobalt-free low nickel maraging steel have been produced through electroslag remelting (ESR) process. The corrosion resistance of these ESR steels was investigated in 1 M H2SO4 solution using linear potentiodynamic polarization (LPP) and electrochemical impedance spectroscopy (EIS) techniques. The experiments were performed for different immersion time and solution temperature. To evaluate the corrosion resistance of the ESR steels, some significant characterization parameters from LPP and EIS curves were analyzed and compared with that of conventional C250 maraging steel. Irrespective of measurement techniques used, the results show that the corrosion resistance of the ESR steels was higher than the C250 steel. The microstructure of ESR steels was composed of uniform and well-distributed martensite accompanied with little amount of retained austenite in comparison with C250 steel.

  9. Decomposition of time-resolved tomographic PIV

    NARCIS (Netherlands)

    Schmid, P.J.; Violato, D.; Scarano, F.

    2012-01-01

    An experimental study has been conducted on a transitional water jet at a Reynolds number of Re = 5,000. Flow fields have been obtained by means of time-resolved tomographic particle image velocimetry capturing all relevant spatial and temporal scales. The measured threedimensional flow fields have

  10. Ultrafast Time-Resolved Photoluminescence Studies of Gallium-Arsenide

    Science.gov (United States)

    Johnson, Matthew Bruce

    This thesis concerns the study of ultrafast phenomena in GaAs using time-resolved photoluminescence (PL). The thesis consists of five chapters. Chapter one is an introduction, which discusses the study of ultrafast phenomena in semiconductors. Chapter two is a description of the colliding-pulse mode-locked (CPM) ring dye laser, which is at the heart of the experimental apparatus used in this thesis. Chapter three presents a detailed experimental and theoretical investigation of photoluminescence excitation correlation spectroscopy (PECS), the novel technique which is used to time-resolve ultrafast PL phenomena. Chapters 4 and 5 discuss two applications of the PECS technique. In Chapter 4 the variation of PL intensity in In-alloyed GaAs substrate material is studied, while Chapter 5 discusses the variation of carrier lifetimes in ion-damaged GaAs used in photo-conductive circuit elements (PCEs). PECS is a pulse-probe technique that measures the cross correlation of photo-excited carrier populations. The theoretical model employed in this thesis is based upon the rate equation for a simple three-level system consisting of valence and conduction bands and a single trap level. In the limit of radiative band-to-band dominated recombination, no PECS signal should be observed; while in the capture -dominated recombination limit, the PECS signal from the band-to-band PL measures the cross correlation of the excited electron and hole populations and thus, the electron and hole lifetimes. PECS is experimentally investigated using a case study of PL in semi-insulating (SI) GaAs and In -alloyed GaAs. At 77 K, the PECS signal is characteristic of a capture-dominated system, yielding an electron-hole lifetime of about 200 ps. However, at 5 K the behavior is more complicated and shows saturation effects due to the C acceptor level, which is un-ionized at 5 K. As a first application, PECS is used to investigate the large band-to-band PL contrast observed near dislocations in In

  11. Evaluation of flux-trapping and magneto-resistibility of superconductors by ESR spectroscopy; ESR ho ni yoru chodendotai no jisoku hosoku to taijiba tokusei no hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Kusumori, T; Matsuura, K; Muto, H [National Industrial Research Institute of Nagoya, Nagoya (Japan)

    1995-09-28

    The abnormal sisal, which was observed in the ESR measurement of superconductors, was confirmed to be a non-ESR (non resonant) signal, from an ESR experiment applying parallel and vertically polarized microwave fields and from the calculation of the ESR transition probabilities. The field modulation dependence of the spectra revealed that the signal was composed of two components. From the modulation-scheme analysis and a study of type I and II superconductors, two components were assigned to the microwave responses to magnetizations trapped in the crystalline portion and at intergranular Josephson junctions. The former B and the batter J components are observed in the first derivative and absorption a form, respectively, and their polarities differently behave for the field sweep reversal. Based on these results, we have improved an ESR spectrometer, which makes it possible to measure separately two kinds of magnetization and to study the trapping ability and quantum flux. 11 refs., 12 figs., 1 tab.

  12. Exploratory study on a statistical method to analyse time resolved data obtained during nanomaterial exposure measurements

    International Nuclear Information System (INIS)

    Clerc, F; Njiki-Menga, G-H; Witschger, O

    2013-01-01

    Most of the measurement strategies that are suggested at the international level to assess workplace exposure to nanomaterials rely on devices measuring, in real time, airborne particles concentrations (according different metrics). Since none of the instruments to measure aerosols can distinguish a particle of interest to the background aerosol, the statistical analysis of time resolved data requires special attention. So far, very few approaches have been used for statistical analysis in the literature. This ranges from simple qualitative analysis of graphs to the implementation of more complex statistical models. To date, there is still no consensus on a particular approach and the current period is always looking for an appropriate and robust method. In this context, this exploratory study investigates a statistical method to analyse time resolved data based on a Bayesian probabilistic approach. To investigate and illustrate the use of the this statistical method, particle number concentration data from a workplace study that investigated the potential for exposure via inhalation from cleanout operations by sandpapering of a reactor producing nanocomposite thin films have been used. In this workplace study, the background issue has been addressed through the near-field and far-field approaches and several size integrated and time resolved devices have been used. The analysis of the results presented here focuses only on data obtained with two handheld condensation particle counters. While one was measuring at the source of the released particles, the other one was measuring in parallel far-field. The Bayesian probabilistic approach allows a probabilistic modelling of data series, and the observed task is modelled in the form of probability distributions. The probability distributions issuing from time resolved data obtained at the source can be compared with the probability distributions issuing from the time resolved data obtained far-field, leading in a

  13. Elevated seminal plasma estradiol and epigenetic inactivation of ESR1 and ESR2 is associated with CP/CPPS.

    Science.gov (United States)

    Nesheim, Nils; Ellem, Stuart; Dansranjavin, Temuujin; Hagenkötter, Christina; Berg, Elena; Schambeck, Rupert; Schuppe, Hans-Christian; Pilatz, Adrian; Risbridger, Gail; Weidner, Wolfgang; Wagenlehner, Florian; Schagdarsurengin, Undraga

    2018-04-13

    Chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS) is associated with urinary tract symptoms and hormonal imbalances amongst others. The heterogeneous clinical presentation, unexplored molecular background and lack of prostate biopsies complicate therapy. Here, using liquid biopsies, we performed a comprehensive translational study on men diagnosed with CP/CPPS type III ( n = 50; median age 39.8, range 23-65) and age-matched controls ( n = 61; median age 36.8, range 20-69), considering biochemical parameters of blood and ejaculates, and epigenetic regulation of the estrogen receptor genes ( ESR1 and ESR2 ) in leukocytes isolated from blood (systemic regulation) and in somatic cells isolated from ejaculates (local regulation). We found elevated 17β-estradiol (E 2 ) levels in seminal plasma, but not in blood plasma, that was significantly associated with CP/CPPS and impaired urinary tract symptoms. In ejaculated somatic cells of CP/CPPS patients we found that ESR1 and ESR2 were both significantly higher methylated in CpG-promoters and expressionally down-regulated in comparison to controls. Mast cells are reported to contribute to CP/CPPS and are estrogen responsive. Consistent with this, we found that E 2 -treatment of human mast cell lines (HMC-1 and LAD2) resulted in altered cytokine and chemokine expression. Interestingly, in HMC-1 cells, possessing epigenetically inactivated ESR1 and ESR2, E 2 -treatment led to a reduced transcription of a number of inflammatory genes. Overall, these data suggest that elevated local E 2 levels associate with an epigenetic down-regulation of the estrogen receptors and have a prominent role in CP/CPPS. Investigating E 2 levels in semen could therefore serve as a promising biomarker to select patients for estrogen targeted therapy.

  14. Development of force-detected THz-ESR measurement system and its application to metal porphyrin complexes

    Science.gov (United States)

    Takahashi, Hideyuki; Okamoto, Tsubasa; Ohmichi, Eiji; Ohta, Hitoshi

    Electron spin resonance spectroscopy in the terahertz region (THz-ESR) is a promising technique to study biological materials such as metalloproteins because it directly probes the metal ion sites that play an important role in the emergence of functionality. By combining THz-ESR with force detection, the samples mass is reduced to the order of ng. This feature is of great advantage because the sample preparation process of biological materials is time-consuming. We developed a force-detected THz-ESR system utilizing optical interferometry for precise cantilever displacement measurement. In order to suppress the sensitivity fluctuation and instability of cantilever dynamics under high magnetic field, the tuning of interferometer is feedback-controlled during a measurement. By using this system, we successfully observed the ESR signal of hemin, which is a model substance of hemoglobin and myoglobin, in THz region.

  15. Time-resolved optical studies of wide-gap II-VI semiconductor heterostructures

    Science.gov (United States)

    Wang, Hong

    ZnSe and ZnSe-based quantum well and superlattice structures are potential candidates for light emitting devices and other optical devices such as switches and modulators working in the blue-green wavelength range. Carrier dynamics studies of these structures are important in evaluating device performance as well as understanding the underlying physical processes. In this thesis, a carrier dynamics investigation is conducted for temperature from 77K to 295K on CdZnSSe/ZnSSe single quantum well structure (SQW) and ZnSe/ZnSTe superlattice fabricated by molecular beam epitaxy (MBE). Two experimental techniques with femtosecond time resolution are used in this work: up-conversion technique for time- resolved photoluminescence (PL) and pump-probe technique for time-resolved differential absorption studies. For both heterostructures, the radiative recombination is dominated by exciton transition due to the large exciton binding energy as a result of quantum confinement effect. The measured decay time of free exciton PL in CdZnSSe/ZnSSe SQW increases linearly with increasing temperature which agrees with the theoretical prediction by considering the conservation of momentum requirement for radiative recombination. However, the recombination of free carriers is also observed in CdZnSSe/ZnSSe SQW for the whole temperature range studied. On the other hand, in ZnSe/ZnSTe superlattice structures, the non- radiative recombination processes are non-negligible even at 77K and become more important in higher temperature range. The relaxation processes such as spectral hole burning, carrier thermalization and hot-carrier cooling are observed in ZnSe/ZnSTe superlattices at room temperature (295K) by the femtosecond pump-probe measurements. A rapid cooling of the thermalized hot- carrier from 763K to 450K within 4ps is deduced. A large optical nonlinearity (i.e., the induced absorption change) around the heavy-hole exciton energy is also obtained.

  16. High-dose dosimetry using electron spin resonance (ESR) spectroscopy

    International Nuclear Information System (INIS)

    Kojima, Takuji; Tanaka, Ryuichi

    1992-01-01

    An electron spin resonance (ESR) dosimeter capable of measuring large doses of radiation in radiotherapy and radiation processing is outlined. In particular, an alanine/ESR dosimeter is discussed, focusing on the development of elements, the development of the ESR dosimetric system, the application of alanine/ESR dosimeter, and basic researches. Rod elements for gamma radiation and x radiation and film elements for electron beams are described in detail. The following recent applications of the alanine/ESR dosimeter are introduced: using as a transfer dosimeter, applying to various types of radiation, diagnosing the deterioration of radiological materials and equipments, and applying to ESR imaging. The future subjects to be solved in the alanine/ESR dosimetric system are referred to as follows: (1) improvement of highly accurate elements suitable for the measurement of various types of radiation, (2) establishment of sensitive calibration method of the ESR equipment itself, and (3) calibration and standardization of radiation doses. (K.N.) 65 refs

  17. Time-resolved fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gustavsson, Thomas; Mialocq, Jean-Claude

    2007-01-01

    This article addresses the evolution in time of light emitted by a molecular system after a brief photo-excitation. The authors first describe fluorescence from a photo-physical point of view and discuss the characterization of the excited state. Then, they explain some basic notions related to fluorescence characterization (lifetime and decays, quantum efficiency, so on). They present the different experimental methods and techniques currently used to study time-resolved fluorescence. They discuss basic notions of time resolution and spectral reconstruction. They briefly present some conventional methods: intensified Ccd cameras, photo-multipliers and photodiodes associated with a fast oscilloscope, and phase modulation. Other methods and techniques are more precisely presented: time-correlated single photon counting (principle, examples, and fluorescence lifetime imagery), streak camera (principle, examples), and optical methods like the Kerr optical effect (principle and examples) and fluorescence up-conversion (principle and theoretical considerations, examples of application)

  18. Photoluminescence and ESR of glasses of the Ge-S system

    International Nuclear Information System (INIS)

    Cernoskova, E.; Cernosek, Z.; Holubova, J.

    1999-01-01

    In this work the chalcogenide glasses were studied by photoluminescence, electron spin resonance (ESR) as well as optically induce ESR (LESR) methods. Dependence of energy of luminescence and Stokes shift on glass composition was determined

  19. Numerical simulations of time-resolved quantum electronics

    International Nuclear Information System (INIS)

    Gaury, Benoit; Weston, Joseph; Santin, Matthieu; Houzet, Manuel; Groth, Christoph; Waintal, Xavier

    2014-01-01

    Numerical simulation has become a major tool in quantum electronics both for fundamental and applied purposes. While for a long time those simulations focused on stationary properties (e.g. DC currents), the recent experimental trend toward GHz frequencies and beyond has triggered a new interest for handling time-dependent perturbations. As the experimental frequencies get higher, it becomes possible to conceive experiments which are both time-resolved and fast enough to probe the internal quantum dynamics of the system. This paper discusses the technical aspects–mathematical and numerical–associated with the numerical simulations of such a setup in the time domain (i.e. beyond the single-frequency AC limit). After a short review of the state of the art, we develop a theoretical framework for the calculation of time-resolved observables in a general multiterminal system subject to an arbitrary time-dependent perturbation (oscillating electrostatic gates, voltage pulses, time-varying magnetic fields, etc.) The approach is mathematically equivalent to (i) the time-dependent scattering formalism, (ii) the time-resolved non-equilibrium Green’s function (NEGF) formalism and (iii) the partition-free approach. The central object of our theory is a wave function that obeys a simple Schrödinger equation with an additional source term that accounts for the electrons injected from the electrodes. The time-resolved observables (current, density, etc.) and the (inelastic) scattering matrix are simply expressed in terms of this wave function. We use our approach to develop a numerical technique for simulating time-resolved quantum transport. We find that the use of this wave function is advantageous for numerical simulations resulting in a speed up of many orders of magnitude with respect to the direct integration of NEGF equations. Our technique allows one to simulate realistic situations beyond simple models, a subject that was until now beyond the simulation

  20. ESR studies on the influence of physiological dissolution and digestion media on the lipid phase characteristics of SEDDS and SEDDS pellets.

    Science.gov (United States)

    Abdalla, Ahmed; Mäder, Karsten

    2009-02-09

    The aim of the current study is the evaluation of a recently optimized SEDDS, composed of Solutol HS15 and medium chain glycerides, and self-emulsifying pellets by means of ESR. Tempol-benzoate (TB)-loaded SEDDS were produced and electron spin resonance (ESR) spectroscopy was used to evaluate the diluted self-emulsifying mixtures. Moreover, ESR in vitro digestion experiments were carried out to have an insight on the characteristics of the different phases formed during the digestion process and to evaluate the distribution and the localization of TB in these phases. In addition, self-emulsifying pellets were produced using nitroxide-loaded SEDDS and the microenvironment within the pellets during release process was monitored in an online process using ESR spectroscopy. After dilution of nitroxide-loaded SEDDS, the percent of TB localized in the lipophilic compartment was decreasing with increasing the surfactant fraction in the mixture. Moreover, it was found that different phases with variable viscosity and polarity were produced as a result of the enzymatic digestion of SEDDS in physiologically relevant media. This change in lipid composition has largely affected the distribution and the localization of the spin probe during the digestion process. A rapid increase in the mobility of the spin probe inside the pellets was noticed after exposure to the release media. Additionally, TB was localized within the self-emulsifying mixture environment for the time of the experiment. ESR is considered a powerful non-invasive tool to assess the microenvironment of the diluted SEDDS and to monitor in vitro digestion process. Digestion induces a change in lipid composition which can affect the solubilization capacity of the administered drug. Therefore, monitoring in vitro digestion process using ESR spectroscopy will help in providing greater understanding of the interaction between the administered drug and the digested lipid vehicles.

  1. ESR detection of irradiated seashells

    Energy Technology Data Exchange (ETDEWEB)

    Raffi, J. [Laboratoire de Recherche sur la Qualite des Aliments, Faculte de Saint-Jerome, Marseille (France); Hasbany, C. [Laboratoire de Recherche sur la Qualite des Aliments, Faculte de Saint-Jerome, Marseille (France)]|[Laboratoire de Chimie des Produits Naturels, Faculte de Saint-Jerome, Marseille (France); Lesgards, G. [Laboratoire de Chimie des Produits Naturels, Faculte de Saint-Jerome, Marseille (France); Ochin, D. [Institut Agricol et Alimentaire de Lille (France). Lab. de Microbiologie et d`Hygiene Alimentaire

    1996-11-01

    Among the protocols for identification of irradiated foodstuffs submitted to the European Committee of Standardization, two using ESR (food containing bone or cellulose) were finally accepted as official `draft European standards` in Berlin on 9-10 June 1994. We present here some new results for oyster and mussel shells, and an ESR draft protocol is proposed. (author).

  2. The Impact of ESR1 Mutations on the Treatment of Metastatic Breast Cancer.

    Science.gov (United States)

    Pejerrey, Sasha M; Dustin, Derek; Kim, Jin-Ah; Gu, Guowei; Rechoum, Yassine; Fuqua, Suzanne A W

    2018-05-07

    After nearly 20 years of research, it is now established that mutations within the estrogen receptor (ER) gene, ESR1, frequently occur in metastatic breast cancer and influence response to hormone therapy. Though early studies presented differing results, sensitive sequencing techniques now show that ESR1 mutations occur at a frequency between 20 and 40% depending on the assay method. Recent studies have focused on several "hot spot mutations," a cluster of mutations found in the hormone-binding domain of the ESR1 gene. Throughout the course of treatment, tumor evolution can occur, and ESR1 mutations emerge and become enriched in the metastatic setting. Sensitive techniques to continually monitor mutant burden in vivo are needed to effectively treat patients with mutant ESR1. The full impact of these mutations on tumor response to different therapies remains to be determined. However, recent studies indicate that mutant-bearing tumors may be less responsive to specific hormonal therapies, and suggest that aromatase inhibitor (AI) therapy may select for the emergence of ESR1 mutations. Additionally, different mutations may respond discretely to targeted therapies. The need for more preclinical mechanistic studies on ESR1 mutations and the development of better agents to target these mutations are urgently needed. In the future, sequential monitoring of ESR1 mutational status will likely direct personalized therapeutic regimens appropriate to each tumor's unique mutational landscape.

  3. ESR dating of tooth enamel samples

    International Nuclear Information System (INIS)

    Chen Tiemei; Yang quan; Wu En

    1993-01-01

    Five tooth samples from the palaeoanthropological site of Jinniushan were dated with both electron-spin-resonance (ESR) and uranium-series techniques. The ESR age of about 230 ka is in good agreement with the U-series dating result, which confirms the hypothesis of possible coexistence of Homo erect us and Homo sapiens in China. Problems in ESR dating are discussed such as: 1) inappropriate of simple exponential extrapolation for accumulated dose determination; 2)experimental measurement of alpha detection efficiency and radon emanation and 3)selection of U-uptake model

  4. Time-resolved CT angiography in aortic dissection

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Nikolaou, Konstantin; Weidenhagen, Rolf; Hellbach, Katharina; Helck, Andreas; Bamberg, Fabian; Reiser, Maximilian F.; Sommer, Wieland H.

    2012-01-01

    Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 ± 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 ± 3.5 mSv. CT density of the true lumen peaked at 355 ± 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.

  5. [A new measurement method of time-resolved spectrum].

    Science.gov (United States)

    Shi, Zhi-gang; Huang, Shi-hua; Liang, Chun-jun; Lei, Quan-sheng

    2007-02-01

    A new method for measuring time-resolved spectrum (TRS) is brought forward. Programming with assemble language controlled the micro-control-processor (AT89C51), and a kind of peripheral circuit constituted the drive circuit, which drived the stepping motor to run the monochromator. So the light of different kinds of expected wavelength could be obtained. The optical signal was transformed to electrical signal by optical-to-electrical transform with the help of photomultiplier tube (Hamamatsu 1P28). The electrical signal of spectrum data was transmitted to the oscillograph. Connecting the two serial interfaces of RS232 between the oscillograph and computer, the electrical signal of spectrum data could be transmitted to computer for programming to draw the attenuation curve and time-resolved spectrum (TRS) of the swatch. The method for measuring time-resolved spectrum (TRS) features parallel measurement in time scale but serial measurement in wavelength scale. Time-resolved spectrum (TRS) and integrated emission spectrum of Tb3+ in swatch Tb(o-BBA)3 phen were measured using this method. Compared with the real time-resolved spectrum (TRS). It was validated to be feasible, credible and convenient. The 3D spectra of fluorescence intensity-wavelength-time, and the integrated spectrum of the swatch Tb(o-BBA)3 phen are given.

  6. First Isochronous Time-of-Flight Mass Measurements of Short-Lived Projectile Fragments in the ESR

    International Nuclear Information System (INIS)

    Stadlmann, J.; Geissel, H.; Hausmann, M.; Nolden, F.; Radon, T.; Schatz, H.; Scheidenberger, C.; Attallah, F.; Beckert, K.; Bosch, F.; Falch, M.; Franczak, B.; Franzke, B.; Kerscher, Th.; Klepper, O.; Kluge, H.J.; Kozhuharov, C.; Loebner, K.E.G.; Muenzenberg, G.; Novikov, Yu.N.; Steck, M.; Sun, Z.; Suemmerer, K.; Weick, H.; Wollnik, H.

    2000-01-01

    A new method for precise mass measurements of short-lived hot nuclei is presented. These nuclei were produced via projectile fragmentation, separated with the FRS and injected into the storage ring ESR being operated in the isochronous mode. The revolution time of the ions is measured with a time-of-flight detector sensitive to single particles. This new method allows access to exotic nuclei with half-lives in the microsecond region. First results from this novel method obtained with measurements on neutron-deficient fragments of a chromium primary beam with half-lives down to 50 ms are reported. A precision of deltam/m ≤ 5 · 10 -6 has been achieved

  7. Gene Expression Analyses of HER-2/neu and ESR1 in Patients with Breast Cancer

    Directory of Open Access Journals (Sweden)

    Omid Kheyri Nadergoli

    2017-10-01

    Full Text Available ABSTRACT Background: Her-2 and ESR1 genes, that interact in the cell signaling pathway, are the most important molecular markers of breast cancer, which have been amplified or overexpressed in 30% and 70%, respectively. This study was performed to evaluate the gene expression levels of Her-2 and ESR1 genes in tumor cells and its adjacent normal tissue of breast cancer patients and compared them whit clinical-pathological features. Methods: In total, 80 tissue specimens from 40 patients, with an average age of 48.47 years, were examined by Real-time PCR technique, and ultimately evaluated the expression level of Her-2 and ESR1genes. The data were analyzed by REST 2009 V2.0.13 statistical software. Results: HER2 and ESR1 overexpression was identified in 19 (48% and 12 (30% of 40 patients respectively, which was higher and lower than that recorded in international statistics, respectively. ESR1 overexpression was associated with Stage 3A and lymph node involvement 2 (N2 (P = 0.04 and P = 0.047, respectively. No significant correlation was observed between the expression of HER2 and ESR1 and other clinical-pathological features, however, the relative differences were identified in the expression levels of genes between main group and groups that were classified according to the clinical-pathological features and age. Conclusions: Overexpression of Her-2 and ESR1 genes in the patients of our study are higher and lower than international statistics, respectively, indicating the differences in genetic, environmental and ethnic factors that involved in the developing of breast cancer.

  8. Reduction of Guanosyl Radical by Cysteine and Cysteine-Glycine Studied by Time-Resolved CIDNP

    NARCIS (Netherlands)

    Morozova, O.B.; Kaptein, R.; Yurkovskaya, A.V.

    2012-01-01

    As a model for chemical DNA repair, reduction of guanosyl radicals in the reaction with cysteine or the dipeptide cysteine-glycine has been studied by time-resolved chemically induced dynamic nuclear polarization (CIDNP). Radicals were generated photochemically by pulsed laser irradiation of a

  9. Status and outlook of the CRYRING@ESR project

    Energy Technology Data Exchange (ETDEWEB)

    Geithner, W., E-mail: w.geithner@gsi.de; Andelkovic, Z.; Beck, D.; Bräuning, H.; Bräuning-Demian, A. [GSI Helmholtzzentrum für Schwerionenforschung (Germany); Danared, H. [European Spallation Source ESS (Sweden); Dimopoulou, C. [GSI Helmholtzzentrum für Schwerionenforschung (Germany); Engström, M. [Fysikum, Stockholm University (Sweden); Fedotova, S.; Gorda, O.; Herfurth, F.; Hess, R. [GSI Helmholtzzentrum für Schwerionenforschung (Germany); Källberg, A. [Fysikum, Stockholm University (Sweden); Kleffner, C.; Kotovskiy, N.; Kraus, I.; Lestinsky, M.; Litvinov, S.; Nolden, F.; Reiter, A. [GSI Helmholtzzentrum für Schwerionenforschung (Germany); and others

    2017-11-15

    Once operational, CRYRING@ESR will store and decelerate ions delivered by the experimental storage ring ESR at energies well below those of ESR. In addition to that, CRYRING@ESR has an electron cooler operating with an ultracold electron beam, allowing to provide cooled ion beams for precision experiments. These ions will be delivered to a broad range of experiments presently in preparation; either in-ring or extracted to a dedicated beamline for experiments. An overview and status report of the installation and commissioning of the CRYRING-@ESR storage ring for highly charged ions at the GSI Helmholtzzentrum für Schwerionenforschung is presented. The installation of this storage ring started in 2014 and was completing end of 2016, when this publication was written.

  10. Time-Resolved Small-Angle X-Ray Scattering

    NARCIS (Netherlands)

    ten Elshof, Johan E.; Besselink, R.; Stawski, Tomasz; Castricum, H.L.; Levy, D.; Zayat, M.

    2015-01-01

    This chapter focuses on time-resolved studies of nanostructure development in sol-gel liquids, that is, diluted sols, wet gels, and drying thin fffilms. The most commonly investigated classes of sol-gel materials are silica, organically modified silica, template-directed mesostructured silica,

  11. The result of Alanine/ESR dosimetry at Wolsung unit 1

    International Nuclear Information System (INIS)

    Park, Byeong Ryong; Choi, Hoon; Lim, Young Khi

    2008-01-01

    It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and dosimeter weight, were used in calculation of absorbed dose quantity. In this study, dose values which are alinine dosimeter from Wolsong unit 1 are measured by two ESR systems. And then the results was compared each other

  12. Irradiation detection of coffee mate by electron spin resonance (ESR)

    Energy Technology Data Exchange (ETDEWEB)

    Ozsayin, Fulya [Physics Engineering Department, Hacettepe University, 06800 Ankara (Turkey); Polat, Mustafa, E-mail: polat@hacettepe.edu.t [Physics Engineering Department, Hacettepe University, 06800 Ankara (Turkey)

    2011-06-15

    Un-irradiated coffee mate samples do not exhibit any ESR signal. However, the samples exposed to UV and gamma radiation exhibit an ESR singlet and a large unresolved ESR signal, respectively. The dose-response curves of the samples exposed to UV and gamma radiations were found to be described well by an exponential and linear functions, respectively. Variable temperature and fading studies at room temperature showed that the radiation-induced radicals in coffee mate sample are very sensitive to temperature. The discrimination between un-irradiated and irradiated coffee mate samples can be done just comparing their ESR spectra. However, determination of the radiation dose received by the sample cannot be possible because of the fast decay of signal intensity at room temperature.

  13. Radiation processes in organic halides (Cl, Br, I) studied by ESR spectroscopy

    International Nuclear Information System (INIS)

    Symons, M.C.R.

    1980-01-01

    Electron-loss from alkyl halides (Cl, Br, I) gives Rhal. + which may dimerise to give (Rhal-halR) + σ* radicals with characteristic ESR spectra, or may lose H + to give α-halo radicals (R 2 Chal) also with well characterised ESR spectra. Electron-capture gives dissociation, but there may be weak residual charge-transfer interaction between R. and hal - which gives rise to well defined hyperfine coupling from the halide nuclei. Loss of β-hydrogen gives β-halo radicals, R 2 C-CH 2 hal (Cl,Br) whose conformation, established by ESR spectroscopy, is such that the halogen atom lies out of the radical plane so that overlap between the half-filled 2p(π) orbital and the C-hal (σ) orbital is maximised. Electron addition to α-halocarboxylates and related compounds probably gives β-halo radical anions, (R 2 C[hal]CO 2 H) - with a similar preferred conformation. Alternative structures are considered for these species. (author)

  14. Influences of different sample preparation methods on tooth enamel ESR signals

    International Nuclear Information System (INIS)

    Zhang Wenyi; Jiao Ling; Zhang Liang'an; Pan Zhihong; Zeng Hongyu

    2005-01-01

    Objective: To study the influences of different sample preparation methods on tooth enamel ESR signals in order to reduce the effect of dentine on their sensitivities to radiation. Methods: The enamel was separated from dentine of non-irradiated adult teeth by mechanical, chemical, or both methods. The samples of different preparations were scanned by an ESR spectrometer before and after irradiation. Results: The response of ESR signals of samples prepared with different methods to radiation dose was significantly different. Conclusion: The selection of sample preparation method is very important for dose reconstruction by tooth enamel ESR dosimetry, especially in the low dose range. (authors)

  15. Cantilever-detected high-frequency ESR measurement using a backward travelling wave oscillator

    International Nuclear Information System (INIS)

    Tokuda, Y; Hirano, S; Ohmichi, E; Ohta, H

    2012-01-01

    Our cantilever-detected electron spin resonance (ESR) technique is motivated for terahertz ESR spectroscopy of a tiny single crystal at low temperature. In this technique, ESR signal is detected as deflection of a sample-mounted cantilever, which is sensitively detected by built-in piezoresistors. So far, ESR detection at 315 GHz was succeeded using Gunn oscillator. In this study, we combine our ESR technique with a backward traveling wave oscillator (BWO), which can cover a wide frequency range 120-1200 GHz, to achieve better spectral resolution. Experiments were carried out at 4.2 K for a single crystal of Co Tutton salt with a newly constructed optical system. We successfully observed two ESR absorption lines in BWO frequencies up to 370 GHz. From multi-frequency measurements, the observed ESR lines shifted linearly with BWO frequency, being consistent with paramagnetic resonance. The estimated g values are g 1 = 3.00 and g 2 = 3.21. The spin sensitivity was estimated to ∼10 12 spins/gauss at 370 GHz.

  16. ESR analysis of irradiated red peppers and commercial red peppers in Japan

    International Nuclear Information System (INIS)

    Kameya, Hiromi; Ukai, Mitsuko

    2011-01-01

    ESR analysis of γ-ray irradiated and being treated with different processing red pepper was studied. All the red peppers were commercial expect irradiated one. Processing treatment of red pepper was sun drying, mechanical processing (heating sterilization and powdering treatment). All the samples were weighted and analyzed. The ESR spectrum of the red pepper is composed of a singlet at g=2.00. This signal was originated from organic free radical. It is suggested the effect of heating treatment on the radical formation is not so large and powdering treatment will promote the radical formation of red pepper. ESR singlet signal of the irradiated red pepper showed the large signal intensity and the dose-dependence. The singlet signal intensity of irradiated powder sample showed the almost same value as compared with that of the powder sample with heating treatment. Relaxation times (T 1 and T 2 ) of the singlet signal were calculated. The relaxation behavior and relaxation times of the irradiated sample were different from that of the non-irradiated sample. The value of T 1 , the spin lattice relaxation time, of irradiated sample was increased and T 2 , the spin-spin relaxation time, of irradiated sample was decreased. We concluded that the radical formation of the red pepper is mainly depended on the powdering treatment and irradiation. (author)

  17. Assessment of the lower ESR dating range in Greek speleothems

    International Nuclear Information System (INIS)

    Bassiakos, Y.

    2001-01-01

    Pilot ESR dating studies on geologically young calcitic sinters were carried out, aiming at assessment of the lower ESR dating range in characteristic Greek speleoenvironments. Five stalactites were dated, coming from an ancient mining gallery, idle for the last 2,500 years, found on Siphnos island (Aegean). The calculated ages range between 1,7-2,0 ka. Medium to low measured external dose rates (aprox. 900 μGy/a) and very low measured radioelement concentration in samples are very usual in the Mediterranean environments. The study concludes that ESR dating of speleothems younger than two millenia is practically unattainable. Some geoarchaeological implications of the obtained ages are discussed. (author)

  18. Development of portable ESR spectrometer as a reader for alanine dosimeters

    International Nuclear Information System (INIS)

    Kojima, T.; Haruyama, Y.; Tachibana, H.; Tanaka, R.; Okamoto, J.

    1993-01-01

    A prototype portable electron spin resonance (ESR) spectrometer was designed and tested, and its feasibility as a reader of alanine dosimeters was studied from the two standpoints of reproducibility of readings and sensitivity sufficient for dosimetry in the absorbed dose range 1-100 kGy. It has two main components: a permanent magnet and resonator; and a unit box with a microwave and auto-frequency control (AFC) circuit, a sweep controller of magnetic field, display, etc. In the present preliminary study, reproducibility values are measured with the same ESR parameters and alanine-polystyrene (alanine-PS) dosimeter at a dose of 1 kGy: repeatedly measuring without removing dosimeter from the cavity; individual measurement with removing and inserting again into the cavity with readjustment of ESR parameters. Alanine/ESR dosimetry using this spectrometer has a measurable dose range from 1 to 100 kGy with relatively high precision within ± 3% (1σ) as a preliminary result. The portable ESR spectrometer may also be modified as an automatic, more precise, dedicated alanine dosimeter reader. (author)

  19. Time-Resolved Hard X-Ray Spectrometer

    International Nuclear Information System (INIS)

    Kenneth Moya; Ian McKennaa; Thomas Keenana; Michael Cuneob

    2007-01-01

    Wired array studies are being conducted at the SNL Z accelerator to maximize the x-ray generation for inertial confinement fusion targets and high energy density physics experiments. An integral component of these studies is the characterization of the time-resolved spectral content of the x-rays. Due to potential spatial anisotropy in the emitted radiation, it is also critical to diagnose the time-evolved spectral content in a space-resolved manner. To accomplish these two measurement goals, we developed an x-ray spectrometer using a set of high-speed detectors (silicon PIN diodes) with a collimated field-of-view that converged on a 1-cm-diameter spot at the pinch axis. Spectral discrimination is achieved by placing high Z absorbers in front of these detectors. We built two spectrometers to permit simultaneous different angular views of the emitted radiation. Spectral data have been acquired from recent Z shots for the radial and polar views. UNSPEC1 has been adapted to analyze and unfold the measured data to reconstruct the x-ray spectrum. The unfold operator code, UFO2, is being adapted for a more comprehensive spectral unfolding treatment

  20. Unfolding of Ubiquitin Studied by Picosecond Time-Resolved Fluorescence of the Tyrosine Residue

    OpenAIRE

    Noronha, Melinda; Lima, João C.; Bastos, Margarida; Santos, Helena; Maçanita, António L.

    2004-01-01

    The photophysics of the single tyrosine in bovine ubiquitin (UBQ) was studied by picosecond time-resolved fluorescence spectroscopy, as a function of pH and along thermal and chemical unfolding, with the following results: First, at room temperature (25°C) and below pH 1.5, native UBQ shows single-exponential decays. From pH 2 to 7, triple-exponential decays were observed and the three decay times were attributed to the presence of tyrosine, a tyrosine-carboxylate hydrogen-bonded complex, and...

  1. Dose response of artificial irradiation of fluvial sediment sample for ESR dating

    International Nuclear Information System (INIS)

    Liu Chunru; Yin Gongming; Gao Lu; Li Jianping; Han Fei; Lin Min

    2011-01-01

    ESR dating samples need be irradiated to obtain dose response curve and the equivalent dose. The artificial dose rate is about 1 x 10 -1 -1 x 10 2 Gy/min, whereas the natural dose rate is about 3 Gy/ka. Therefore, one must be sure whether the much higher artificial dose rate is suitable for the ESR dating study. In this paper, we use different artificial dose rate to irradiate the same fluvial sample and measure the quartz Al centre ESR signal under the same conditions. The dose response curves are compared, in an attempt to gain a preliminary knowledge on that problem and build a good foundation for our ESR dating studies on fluvial samples. (authors)

  2. Effect of surfactant coating on magnetic properties of Fe3O4 nanoparticles: ESR study

    International Nuclear Information System (INIS)

    Koeseoglu, Yueksel

    2006-01-01

    Magnetic properties of surfactant-coated and uncoated superparamagnetic iron oxide nanoparticles, Fe 3 O 4 (SPION) were investigated by electron spin resonance (ESR) technique. For all samples, a strong and broad single ESR signal has been observed at all temperatures. A strong temperature dependence of ESR linewidth and resonance field is observed. Also, there is a strong effect of surfactant coating on magnetic properties of Fe 3 O 4 nanoparticles. While the resonance field is decreasing by coating, the linewidth of the ESR spectra is increasing. These changes in resonance field and the linewidth are attributed to the decrease in effective magnetic moment due to a non-collinear spin structure originated from the pinning of the surface spins and coated surfactant at the interface of nanoparticles. Also, the changes are due to the contribution of the volume of the diamagnetic coating mass to the sample volume

  3. ESR analysis of natural and gamma irradiated coriander (Coriandrum sativum L.) seeds

    Science.gov (United States)

    Sezer, M. Özgür; Kaplan, Necati; Sayin, Ulku

    2017-12-01

    Electron spin resonance (ESR) is a powerful technique to detect radicals trapped in cellulosic food products and has been suggested as a useful method for identification of irradiated herbal foodstuffs. Coriander spice which has important medicinal properties was investigated using ESR spectroscopy. Radicals in natural and irradiated coriander samples were determined at room temperature. ESR spectra of natural sample were characterized by a single central signal with ? value and gamma irradiation produced satellite peaks attributed to cellulose-like radical which is used as a marker for detection of irradiated cellulosic plant products. The spectroscopic splitting values of radicals were determined. Dose dependency and stability of this center were analyzed by dose response and kinetic measurements. The reported results about activation energy, thermal life time and dose response relationship of the cellulose-like radical accurately prove that ESR can be used for identification of irradiated coriander spice seeds.

  4. Introduction to Time-Resolved Spectroscopy: Nanosecond Transient Absorption and Time-Resolved Fluorescence of Eosin B

    Science.gov (United States)

    Farr, Erik P.; Quintana, Jason C.; Reynoso, Vanessa; Ruberry, Josiah D.; Shin, Wook R.; Swartz, Kevin R.

    2018-01-01

    Here we present a new undergraduate laboratory that will introduce the concepts of time-resolved spectroscopy and provide insight into the natural time scales on which chemical dynamics occur through direct measurement. A quantitative treatment of the acquired data will provide a deeper understanding of the role of quantum mechanics and various…

  5. ESR study of weakly irradiated organic conductors: TMTSF-DMTCNQ and (TMTSF)2PF6

    International Nuclear Information System (INIS)

    Forro, L.; Beuneu, F.

    1982-01-01

    ESR experiments are presented on irradiated TMTSF-DMTCNQ and (TMTSF) 2 PF 6 . They suggest that a weak disorder extends the metallic phases to low temperatures. Surprisingly, disorder has no effect on the ESR linewidth of (TMTSF) 2 PF 6 between 20 and 30 K, where the d.c. conductivity changes a lot with disorder. (author)

  6. ESR Studies and Dating of Egyptian Gypsum at Ras Mala'ab, Sinai, Egypt

    International Nuclear Information System (INIS)

    Abdel-Monem, A. A.; Abdei-Razek, Y. A.; Rasheed, N. M.; Hassan, G.M.; Eissa, H.M.; El-Morsy, M.

    2007-01-01

    A gypsum sample from the famous gypsum-anhydrite evaporitic deposit composing the Ras Mala'ab Formation, Upper Miocene, occurring at Ras Mala'ab, on the east coast of the Gulf of Suez, was subjected to (ESR) dosimetric studies. Also, (ESR) was used to date the formation or most recent recrystallization of that gypsum. The gypsum derivative (ESR) spectrum is characterized by the large broad Fe 2+ signal (g=2.50) and HF-sixtet Mn 2+ signals. Only the characteristic gypsum signal (G l, g=2.0040) was detected between the third and fourth lines of the HF-Mn 2+ which is attributed to the electron-center SO 3 - . This signal was sensitive to artificial γ-irradiation and showed significant enhancement using a γ-dose of 550 Gy. Also, the signal was very stable up to 400 o C. The gypsum sample with a total dose (TD) of 1500 Gy, determined graphically by extrapolating the linear relationship between defect concentration and the artificial γ-doses for (G l, g=2.0040) and an annual dose (D) due to cosmic rays (0.3 mGy), yielded an age of 5.00 Ma. This could mean the age of formation or latest recrystallization of this gypsum deposit. The geologic age assignment of the Ras Mala'ab Group including the evaporitic gypsum unit, is Middle to Late Miocene. It is directly overlain by the Pliocene elastics at the locality of Ras Mala'ab. This might suggest that these evaporitic gypsum facies represent the top of the Miocene in the Gulf of Suez area, since the Miocene-Pliocene boundary is now put at 5.00-5.50 Ma ago. Therefore, the ESR age of the Ras Mala'ab gypsum is consistent with the geologic age assignment

  7. The discrimination of some dermal dischromias using the ESR and NAA

    International Nuclear Information System (INIS)

    Georgescu, Rodica; Saidel, Alice; Cristodulo, Tania; Saidel, M.

    1997-01-01

    The information provided by the electron spin resonance (ESR) and neutron activation analysis (NAA) seem to complete each other most of time. ESR is applied in biology, due to its significant sensitivity and selectivity in the detection of paramagnetic states of free radicals implied in many physiological processes. Many enzymatic systems, photosynthesis intermediates or electrons transporting chain species are paramagnetic. On the other hand, free radicals are involved in the protection against ionic radiation, in immunity reactions and pathological processes including the oncogenesis. ESR spectroscopy informs about the quantity, interactions and dynamics of paramagnetic centres of the systems through spectral parameters as: the intensity, the g factor, the form and the width of line, hyperfine splitting, etc. NAA allows simultaneous determination of the concentration of essential microelements in tissues involved in the major biological pathways. In the present work we have tested the possibility of using the ESR and NAA investigations techniques combined with the factorial statistic analysis of the data, in the aim to discriminate some dermal dischromias of human skin. Having in view that the hyper- and hipochromia are due to an excess and deficit in melanin, respectively, we used ESR to observe the radical species from the skin samples. We studied the skin samples that represent different dischromias (malign melanoma, epithelioma, pigmentary nevus, vitiligo) in comparison with normal skin. On the same samples we have determined by NAA the concentrations of elements (Cu, Na, Mg, Mn, and Al) which could be involved in the mechanisms of producing and releasing the melanin. The signal ESR intensities and widths and the NAA elemental concentration values of the skin samples have been processed by a STATCF program to develop differences between dischromic and normal skin. The signification level of the differences observed among the sample groups has been evaluated

  8. The use of ESR spectroscopy for the identification of irradiated food

    Energy Technology Data Exchange (ETDEWEB)

    Gray, R [Dept. of Agriculture for Northern Ireland, Belfast (United Kingdom). Food and Agricultural Chemistry Research Div.; Stevenson, M H [Dept. of Agriculture for Northern Ireland, Belfast (United Kingdom). Food and Agricultural Chemistry Research Div. Queen' s Univ., Belfast, Northern Ireland (United Kingdom)

    1991-01-01

    In these days, there is a growing interest in reliable methods for the identification of foods treated with ionising rays. The authors have chosen chicken and lobster as examples to demonstrate the usefulness of ESR spectroscopy in the detection of such irradiation treatments. Furthermore, it could be shown that even after some time had elapsed there still was a direct relation between ESR signals and the irradiation dose originally used, which fact appears to provide a basis for the development of quantitative methods for the detection of irradiation treatment at any later point of time. (orig.).

  9. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  10. Screening of irradiated food using ESR measurement of paper

    International Nuclear Information System (INIS)

    Goto, Michiko; Yamazaki, Masao

    2005-01-01

    As paper has high content of cellulose, sensibility of ESR measurements of paper should be high. We examined stability of ESR signals in irradiated recycled copying paper, and estimated the possibility to utilize ESR measurement of paper for the detection of irradiated food. Cellulose radicals in paper irradiated at 1kGy and stored at 40degC in water was detected for 20 days. Cellulose radicals in irradiated paper stored at 90degC in water were more stable than that stored in air. ESR measurements of 50mg paper are simple and easy, so ESR measurement of rapping paper or corrugated box is good screening method for the detection of irradiated food. (author)

  11. Time-resolved spectroscopy of the probe fluorescence in the study of human blood protein dynamic structure on SR beam

    International Nuclear Information System (INIS)

    Dobretsov, G.E.; Kurek, N.K.; Syrejshchikova, T.I.; Yakimenko, M.N.; Clarke, D.T.; Jones, G.R.; Munro, I.H.

    2000-01-01

    Time-resolved spectroscopy on the SRS of the Daresbury Laboratory was used for the study of the human serum lipoproteins and human blood albumins with fluorescent probes K-37 and K-35, developed in Russia. The probe K-37 was found sensitive to the difference in dynamic properties of the lipid objects. Two sets of the parameters were used for the description of lipid dynamic structure: (1) time-resolved fluorescence spectra and (2) time-resolved fluorescence depolarization as a function of rotational mobility of lipid molecules. Each measured dynamic parameter reflected the monotonous changes of dynamic properties in the range: lipid spheres-very low density lipoproteins-low density lipoproteins-high density lipoproteins-phospholipid liposomes. The range is characterized by the increase of the ratio polar/ nonpolar lipids. Thus, time-resolved fluorescence could be used to detect some structural modifications in lipoproteins related to atherosclerosis and subsequent cardiovascular diseases development

  12. [Relations between plasma-erythrocyte viscosity factors and ESR].

    Science.gov (United States)

    Cortinovis, A; Crippa, A; Crippa, M; Bosoni, T; Moratti, R

    1992-09-01

    The ESR is usually put in relationship: to the real density of the RBCs (erythrocytes) (difference between the RBC specific gravity and the plasma one), and to the resistance that the RBCs meet moving in a medium, which is due to the plasma viscosity and to the total external RBC surface. When the RBCs take shape of aggregates, their external surface is decreased and ESR increases. The most important plasma factor causing changes in ESR is the fibrinogen level followed by the plasma globulins and by the products arising from the tissue damage. The resistance that the RBCs meet moving in the plasma is well expressed by the measurement of the plasma-RBC viscosity considering that is inclusive of both factors that are the plasma viscosity and the external RBC surface. The plasma-RBC viscosity is the resultant of several factors: Fa = Fb - Fe - Fs - Fm, were: Fa is the resultant, Fb the attracting forces due to the proteic macromolecules, Fe the repulsing forces due the negative charges. Fs the repulsing forces due to the shear-stress, Fm the force which opposes itself against the surface tension of the aggregation; it depends on the RBC morphology and on the RBC rigidity. The ESR has been recently used like an index of the RBC aggregation. The Authors study the relationship between several hemorheological parameters and the ESR in infective and inflammatory processes.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Investigation of free radicals in paprika with the ESR method

    International Nuclear Information System (INIS)

    Kispeter, J.; Szabo, I.; Horvath, L.J.

    1998-01-01

    Complete text of publication follows. The ESR method is the one of the most successfully applied method among the physical methods for the identification of radiation or ionising treatment of foods. The identification of free radicals having short and long lifetimes is the base of the measurement. The quantitative determination makes possible the determination of the absorbed dose deriving from 60 Co radiation treatment. It has to be noted that the treatment of the foods with ionising radiation and other treatments (milling, frying, baking) and the oxidative process result free radicals in paprika samples as a function of absorbed radiation dose (2.5; 5 and 10 kGy) on the different particle size and on storage time. The intensities of the samples given after each of the seven stages of the paprika milling increased till the fifth stage corresponding to the effect of a 2 kGy absorbed dose. After conditioning and increasing the water content by 5-8% the ESR intensity shows significant lowering. This value characterises the ESR intensity of not irradiated sample. As an effect of the irradiation the ESR intensities increased along with the increase of the absorbed dose. The samples having lower particle size are more sensible for the identification of the irradiation. Evaluating the art of the decline we concluded that there are free radicals having short and long shelf lifetimes in paprika samples at the same time

  14. ESR dosimetry of optically bleached quartz grains extracted from Plio-Quaternary sediment: Evaluating some key aspects of the ESR signals associated to the Ti-centers

    International Nuclear Information System (INIS)

    Duval, Mathieu; Guilarte, Verónica

    2015-01-01

    The present study aims at investigating several key aspects of ESR dose reconstruction of quartz grains based on the analysis of the Ti-center: (i) the evaluation of the ESR intensity, (ii) its impact on measurements precision, and (iii) the potential of various fitting functions to describe the behavior of the signal with the radiation absorbed dose. In contrast with the Al center, the various Ti centers have quite low ESR signal intensities. It is thus crucial to adapt the experimental conditions for the optimization of the signal-to-noise ratio and to perform repeated measurements in order to take into consideration the uncertainty associated to angular dependence of the signal as well as day-to-day variations. Several options (named A to E) for evaluating the ESR intensity of the Ti–Li and Ti–H centers are explored and some of them yield too much experimental uncertainty (e.g. options C and E) and are apparently not suitable for accurate ESR dosimetry. In contrast, options A and D usually provide similar equivalent dose (D E ) results and can be used together for assessing the dose absorbed by the Ti–Li center. Our results show a systematic non-monotonic behavior of the ESR signal of the Ti center with the dose, which raise some questions about the suitability of the single saturating exponential (SSE) function that is classically used in ESR dating. Consequently, we explored the potential of other functions that can describe the “radiation bleaching” phenomenon observed at high doses. We recommend the use of a specific fitting function (called Ti-2 in the present paper) previously proposed by Woda and Wagner (2007) for any dose reconstruction, and define some criteria to ensure a good fitting. The SSE function provides D E results that are, in most cases, relatively consistent with those derived from the Ti-2, suggesting that the Ti centers apparently follow a SSE behavior up to, at least, 6.0–6.5 kGy However, the reliability of the D E values

  15. The Evaluation of IL6 and ESR1 Gene Polymorphisms in Primary Dysmenorrhea.

    Science.gov (United States)

    Ozsoy, Asker Zeki; Karakus, Nevin; Yigit, Serbulent; Cakmak, Bulent; Nacar, Mehmet Can; Yılmaz Dogru, Hatice

    2016-01-01

    Primary dysmenorrhea is the most common gynecological complaint with painful menstrual cramps in pelvis without any pathology. It affects about half of menstruating women, and it causes significant disruption in quality of life. We investigated the association between IL6 gene promoter and ESR1 gene XbaI and PvuII polymorphisms and primary dysmenorrhea. In this case-control study, 152 unrelated young women with primary dysmenorrhea and 150 unrelated healthy age-matched controls participated. Genomic DNA was isolated and IL6 and ESR1 gene polymorphisms were genotyped using PCR-based RFLP assay. The distribution of genotype and allele frequencies of IL6 gene promoter and ESR1 gene XbaI polymorphisms were not statistically different between patients and controls (p > 0.05). However, the genotype and allele frequencies of ESR1 gene PvuII polymorphism showed statistically significant differences between primary dysmenorrhea patients and controls (p = 0.009 and p = 0.021, respectively). Statistically significant associations were also observed between age and married status of primary dysmenorrhea patients and ESR1 gene PvuII polymorphism (p = 0.044 and p = 0.023, respectively). In combined genotype analyses, AG at ESR1 XbaI and TC at ESR1 PvuII loci encoded a p-value of 0.027. Thus, individuals who are heterozygote at both loci have a lower risk of developing primary dysmenorrhea. Our study suggests no strong association between IL6 gene promoter and ESR1 gene XbaI polymorphisms and primary dysmenorrhea in Turkish women. However, ESR1 gene PvuII polymorphism showed statistically significant differences between primary dysmenorrhea patients and controls. The potential association between ESR1 gene PvuII polymorphism and age and married status of dysmenorrhea patients deserves further consideration.

  16. Fast time-resolved aerosol collector: proof of concept

    Science.gov (United States)

    Yu, X.-Y.; Cowin, J. P.; Iedema, M. J.; Ali, H.

    2010-10-01

    Atmospheric particles can be collected in the field on substrates for subsequent laboratory analysis via chemically sensitive single particle methods such as scanning electron microscopy with energy dispersive x-ray analysis. With moving substrates time resolution of seconds to minutes can be achieved. In this paper, we demonstrate how to increase the time resolution when collecting particles on a substrate to a few milliseconds to provide real-time information. Our fast time-resolved aerosol collector ("Fast-TRAC") microscopically observes the particle collection on a substrate and records an on-line video. Particle arrivals are resolved to within a single frame (4-17 ms in this setup), and the spatial locations are matched to the subsequent single particle analysis. This approach also provides in-situ information on particle size and number concentration. Applications are expected in airborne studies of cloud microstructure, pollution plumes, and surface long-term monitoring.

  17. ESR study of thermal demagnetization processes in ferromagnetic nanoparticles with Curie temperatures between 40 and 60 deg. C

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Oleg A. [Institute of Biochemical Physics, Russian Academy of Sciences (RAS), Kosygin St. 4, Moscow 119991 (Russian Federation)]. E-mail: kuznetsov_oa@yahoo.com; Sorokina, Olga N. [Institute of Biochemical Physics, Russian Academy of Sciences (RAS), Kosygin St. 4, Moscow 119991 (Russian Federation); Leontiev, Vladimir G. [Institute of Metallurgy, Russian Academy of Sciences (RAS), Moscow 119991 (Russian Federation); Shlyakhtin, Oleg A. [Institute of Chemical Physics, Russian Academy of Sciences (RAS), Kosygin St. 4, Moscow 119991 (Russian Federation); Kovarski, Alexander L. [Institute of Biochemical Physics, Russian Academy of Sciences (RAS), Kosygin St. 4, Moscow 119991 (Russian Federation); Kuznetsov, Anatoly A. [Institute of Biochemical Physics, Russian Academy of Sciences (RAS), Kosygin St. 4, Moscow 119991 (Russian Federation)

    2007-04-15

    Thermal demagnetization in the vicinity of the Curie temperature of silver and sodium manganite nanoparticles, as well as copper-nickel and palladium-nickel alloy nanoparticles were studied by both static magnetic measurements and by electron spin resonance (ESR). ESR data indicate that some magnetic ordering remains even above the Curie temperature, determined by static magnetometry. Mechanisms of thermal demagnetization in alloy nanoparticles appear to be different from that in manganites.

  18. ESR study of thermal demagnetization processes in ferromagnetic nanoparticles with Curie temperatures between 40 and 60 deg. C

    International Nuclear Information System (INIS)

    Kuznetsov, Oleg A.; Sorokina, Olga N.; Leontiev, Vladimir G.; Shlyakhtin, Oleg A.; Kovarski, Alexander L.; Kuznetsov, Anatoly A.

    2007-01-01

    Thermal demagnetization in the vicinity of the Curie temperature of silver and sodium manganite nanoparticles, as well as copper-nickel and palladium-nickel alloy nanoparticles were studied by both static magnetic measurements and by electron spin resonance (ESR). ESR data indicate that some magnetic ordering remains even above the Curie temperature, determined by static magnetometry. Mechanisms of thermal demagnetization in alloy nanoparticles appear to be different from that in manganites

  19. An ESR study on the detection of irradiated red lentil

    International Nuclear Information System (INIS)

    Ercan, I.; Eken, M.

    2001-01-01

    The purpose of this work is to investigate in detail detection of irradiated red lentil. In this way, red lentil powder was analysed by using Bruker EMX ESR spectrometer before and after irradiation between the doses 1-9 kGy at ambient conditions. It was observed that seeds of non-irradiated and irradiated red lentil have a signal having six lines due to Mn''+''2 content. However hull of the red lentil has a single line whose origin is still unknown. Besides, this signal has superposed with the radiation induced one. It was also found that the intensity of radiation induced signal was decreased logarithmically in time, and the change in the intensity was minimal at low doses

  20. ESR signals in quartz for the studies of earth surface processes

    Science.gov (United States)

    Toyoda, S.; Shimada, A., , Dr; Takada, M.

    2017-12-01

    Various ESR (electron spin resonance) signals are observed in quartz. As they are formed by natural radiation, the signals are useful in dating of geological events, such as volcanic eruption, faulting and sedimentation. It was also found that those paramagnetic defects can be fingerprints of sediments, to be used for studies in sediment provenance. The signal of the E1' center, unpaired electron at an oxygen vacancy, was first used for such studies. A method was proposed to estimate the number of the precursors (oxygen vacancies) from the E1' center intensity. The number of oxygen vacancies in quartz was found to have positive correlation with the crystallization age. Using this feature, studies were quite successful in aeolian dust. It was shown that the sources of aeolian dust deposited in northern part of Japanese Islands were different between in MIS1 and MIS 2. In combination with crystallinity index, the contributions of the dust components from three origins were quantitatively obtained. After these, the provenance studies on river sediments have started where the impurity centers in quartz were employed, which are the Al center, the Ti centers, and the Ge centers. Sediments of Kizu River, Mie to Nara prefectures in Central Japan are most extensively studied. Firstly, it was shown that each of possible sources of granitic quartz around the reaches has respective characteristics in the number of oxygen vacancies and the signal intensities of impurity centers. Secondary, by the artificial mixing experiments, the impurity signal intensities have the values consistent with the mixing ratio of the two samples of quartz with different intensities. At river junctions, the mixing ratios were calculated from the ESR signals. At some locations, the mixing ratio values obtained from one signal were consistent with the ones from another signal while at some locations they were not. The latter inconsistent results would indicate that the river sediments are

  1. Dose determination by ESR in an accident, using cotton fabric

    International Nuclear Information System (INIS)

    Venkataramani, R.; Mehta, S.K.; Iyer, M.R.; Natarajan, V.; Sastry, M.D.

    1993-01-01

    Accidental exposure dose assessment by electron spin resonance (ESR) technique from the free radicals generated in a cotton handkerchief has been attempted in this investigation. The cotton handkerchief, a common material carried by individuals, was taken as the medium for free radical estimation. About 55 mg of the irradiated piece of cloth was loaded into a quartz tube and the dose dependence of the ESR signal at g = 2.0026 was measured at room temperature, using a Bruker ESP-300 ESR spectrometer in X-band (9.74 GHz). The intensity of this signal was found to be proportional to the dose in the range of 1-1000 Gy. The stability of the free radicals with time of storage was followed. Dependence of dose rate as well as the presence of water on the yield of free radicals were also investigated. (author) 5 refs.; 4 figs.; 2 tabs

  2. Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources.

    Science.gov (United States)

    Rutherford, Michael E; Chapman, David J; White, Thomas G; Drakopoulos, Michael; Rack, Alexander; Eakins, Daniel E

    2016-05-01

    The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is targeted at two-dimensional integrating detector methods, such as those focused on dynamic radiography and diffraction experiments. The response of a scintillator to periodic synchrotron X-ray excitation is modelled and validated against experimental data collected at the Diamond Light Source (DLS) and European Synchrotron Radiation Facility (ESRF). An upper bound on the dynamic range accessible in a time-resolved experiment for a given bunch separation is calculated for a range of scintillators. New bunch structures are suggested for DLS and ESRF using the highest-performing commercially available crystal LYSO:Ce, allowing time-resolved experiments with an interframe time of 189 ns and a maximum dynamic range of 98 (6.6 bits).

  3. Alanine-ESR dosimetry for radiotherapy IAEA experience

    International Nuclear Information System (INIS)

    Mehta, K.; Girzikowsky, R.; )

    1997-01-01

    At present, the most commonly used transfer dosimeters for radiotherapy applications are TL dosemeters. They are being used for intercomparison between SSDLs (about 70) and the IAEA dosimetry laboratory. However, there are some undesirable characteristics of this dosimetry system. We have a study in progress at the IAEA to evaluate the alanine-ESR systems as an alternative to TLDs. There are several desirable qualities which make alanine an attractive dosemeter. Preliminary data suggest that the alanine-ESR dosimetry system has the potential to replace TLDs for intercomparison amongst SSDLs in the therapy-level dose regions. (Author)

  4. An ESR study of the spectra of paint pigments in 'drying' linseed oil

    International Nuclear Information System (INIS)

    Slogett, R.; Troup, G.; Hutton, D.

    1999-01-01

    Full text: Since previous ESR work on the identification of RAW paint pigments, mainly mineral, looked promising, we decided to examine the spectra when the pigments were applied, in oil, to a non-reactive, microwave transparent polymer. The polymer used shows no significant ESR signals in the range 2000-4000 gauss at ∼9.1 GHz and room temperature. The oil used is Winsor and Newton Drying Linseed Oil, and contains 'manganese driers'. The spectrum of the pure liquid oil is shown, as well as that of the dried oil on the substrate. Many of the pigment spectra shown are so strong that not a trace of the oil Mn(2+) can be seen at the pigment concentrations used. The effect of the linseed oil on modern synthetic indigo, an organic pigment still available made from plants, is also shown. ESR still looks to be a useful supplementary technique for paint pigment identification

  5. ESRS guidelines for software safety reviews. Reference document for the organization and conduct of Engineering Safety Review Services (ESRS) on software important to safety in nuclear power plants

    International Nuclear Information System (INIS)

    2000-01-01

    The IAEA provides safety review services to assist Member States in the application of safety standards and, in particular, to evaluate and facilitate improvements in nuclear power plant safety performance. Complementary to the Operational Safety Review Team (OSART) and the International Regulatory Review Team (IRRT) services are the Engineering Safety Review Services (ESRS), which include reviews of siting, external events and structural safety, design safety, fire safety, ageing management and software safety. Software is of increasing importance to safety in nuclear power plants as the use of computer based equipment and systems, controlled by software, is increasing in new and older plants. Computer based devices are used in both safety related applications (such as process control and monitoring) and safety critical applications (such as reactor protection). Their dependability can only be ensured if a systematic, fully documented and reviewable engineering process is used. The ESRS on software safety are designed to assist a nuclear power plant or a regulatory body of a Member State in the review of documentation relating to the development, application and safety assessment of software embedded in computer based systems important to safety in nuclear power plants. The software safety reviews can be tailored to the specific needs of the requesting organization. Examples of such reviews are: project planning reviews, reviews of specific issues and reviews prior final acceptance. This report gives information on the possible scope of ESRS software safety reviews and guidance on the organization and conduct of the reviews. It is aimed at Member States considering these reviews and IAEA staff and external experts performing the reviews. The ESRS software safety reviews evaluate the degree to which software documents show that the development process and the final product conform to international standards, guidelines and current practices. Recommendations are

  6. Experimental Progress in Fast Cooling in the ESR

    CERN Document Server

    Steck, Markus; Beller, Peter; Franzke, Bernhard; Nolden, Fritz

    2005-01-01

    The ESR storage ring at GSI is operated with highly charged heavy ions. Due to the high electric charge the ions interact much stronger with electromagnetic fields. Therefore both cooling methods which are applied to stored ions in the ESR, stochastic cooling and electron cooling, are more powerful than for singly charged particles. The experimental results exhibit cooling times for stochastic cooling of a few seconds. For cold ion beams, electron cooling provides cooling times which are one to two orders of magnitude smaller. The beams are cooled to beam parameters which are limited by intrabeam scattering. At small ion numbers, however, intrabeam scattering is suppressed by electron cooling, clear evidence was found that the ion beam forms a one-dimensional ordered structure, a linear chain of ions. The strengths of stochastic cooling and electron cooling are complementary and can be combined favorably. Stochastic cooling is employed for pre-cooling of hot secondary beams followed by electron cooling to pro...

  7. ESR dating of laterite from Ban Tha Ta Suea, Kanchanaburi, Thailand

    International Nuclear Information System (INIS)

    Limsuwan, S.; Vichaidid, T.; Limsuwan, P.

    2011-01-01

    Electron spin resonance (ESR) dating was carried out on laterite samples collected from Ban Tha Ta Suea, the original deposit of the laterite used in the construction of Muang Sing Historical Park. Ban Tha Ta Suea is about 6 km east of Muang Sing Historical Park in Kanchanaburi province (181 km far from Bangkok). The dose response of the g=2.0028 ESR signal was found to be suitable for age determination. An exponential saturation function was fitted to the ESR signal growth on additional γ-irradiation. Extrapolation of this function resulted in the accumulated dose 144±5 Gy. Gamma spectroscopy and neutron activation analysis (NAA) were used to determine concentrations of 238 U, 232 Th and 40 K in the samples from which the annual dose rate 16±2 mGy was calculated. In addition, the dose rate of cosmic rays was taken into account. The ESR age of laterite samples was found to be 9.0±0.9 ka. This age falls within the Holocene epoch of the Quaternary on the geological time scale. Samples from Muang Sing Historical Park were assigned to the same epoch. Both results agree with the geological map.

  8. Time-resolved photoelectron spectrometry of a dephasing process in pyrazine

    International Nuclear Information System (INIS)

    Pavlov, R.L.; Pavlov, L.I.; Delchev, Ya.I.; Pavlova, S.I.

    2001-01-01

    The first femtosecond time-resolved photoelectron imaging (PEI) is presented. The method is characterized by photoionization of NO and further applied to ultrafast dephasing in pyrazine. Intermediate case behaviour in radiationless transition is clearly observed in time-resolved photoelectron kinetic energy distribution. Femtosecond PEI is with much improved efficiency than conventional photoelectron spectroscopies. It is anticipated that the unifield approach of time-resolved photoelectron and photoion imaging opens the possibility of observing photon-induced dynamics in real time

  9. ESR analysis of irradiated frogs' legs and fishes

    International Nuclear Information System (INIS)

    Raffi, J.; Agnel, J.-P.; Evans, J.C.; Rowlands, C.C.; Lesgards, G.

    1989-01-01

    Electron spin resonance (ESR) spectral analysis of different parts (bones, scales, jaw, etc.) from ionized (irradiated) frozen frogs' legs and fishes (brown trout and sardine) were recorded. There is always present, after treatment, a signal due to the irradiation. ESR and ENDOR experiments lead us to assign it to h 1 centers from hydroxyapatite, as in the case of other irradiated meat bones. The use of ESR to prove whether one of these foods has been irradiated or not is discussed. (author)

  10. Improvements in brain activation detection using time-resolved diffuse optical means

    Science.gov (United States)

    Montcel, Bruno; Chabrier, Renee; Poulet, Patrick

    2005-08-01

    An experimental method based on time-resolved absorbance difference is described. The absorbance difference is calculated over each temporal step of the optical signal with the time-resolved Beer-Lambert law. Finite element simulations show that each step corresponds to a different scanned zone and that cerebral contribution increases with the arrival time of photons. Experiments are conducted at 690 and 830 nm with a time-resolved system consisting of picosecond laser diodes, micro-channel plate photo-multiplier tube and photon counting modules. The hemodynamic response to a short finger tapping stimulus is measured over the motor cortex. Time-resolved absorbance difference maps show that variations in the optical signals are not localized in superficial regions of the head, which testify for their cerebral origin. Furthermore improvements in the detection of cerebral activation is achieved through the increase of variations in absorbance by a factor of almost 5 for time-resolved measurements as compared to non-time-resolved measurements.

  11. Emerging biomedical applications of time-resolved fluorescence spectroscopy

    Science.gov (United States)

    Lakowicz, Joseph R.; Szmacinski, Henryk; Koen, Peter A.

    1994-07-01

    Time-resolved fluorescence spectroscopy is presently regarded as a research tool in biochemistry, biophysics, and chemical physics. Advances in laser technology, the development of long-wavelength probes, and the use of lifetime-based methods are resulting in the rapid migration of time-resolved fluorescence to the clinical chemistry lab, to the patient's bedside, to flow cytometers, to the doctor's office, and even to home health care. Additionally, time-resolved imaging is now a reality in fluorescence microscopy, and will provide chemical imaging of a variety of intracellular analytes and/or cellular phenomena. In this overview paper we attempt to describe some of the opportunities available using chemical sensing based on fluorescence lifetimes, and to predict those applications of lifetime-based sensing which are most likely in the near future.

  12. ESR application to radiation chemistry of polymers

    International Nuclear Information System (INIS)

    Kashiwabara, H.

    1988-01-01

    Important results obtained in our group in the field of ESR application to the study of irradiated polymers are summarized. They are the analysis of the decay reaction of the free radicals, spur-like trapping of the free radicals and the related discussions. A diffusion controlled bimolecular reaction scheme was a good way of analyzing the data of the decay reaction. Power saturation phenomenon of ESR spectra of the free radicals showed a circumstance of the spur-like trapping of the free radicals in irradiated polyethylene. The phenomenon of spur-like trapping was quite consistent with the interpretation of the decay reaction of the free radicals. (author)

  13. ESR study on hydrogen-atom abstraction in cryogenic organic solids

    International Nuclear Information System (INIS)

    Ichikawa, Tsuneki

    1995-01-01

    The present paper summarizes our recent results on the hydrogen-atom abstraction from protiated alkane molecule by deuterium atoms in cryogenic deuterated organic solids, obtained by the X-band ESR and electron spin-echo measurements of the product alkyl radicals at cryogenic temperatures. (J.P.N.)

  14. DETECTION OF SOME IRRADIATED NUTS BY ELECTRON SPIN RESONANCE (ESR) TECHNIQUE

    Energy Technology Data Exchange (ETDEWEB)

    KHALLAF, M F; YASIN, N M.N. [Food Science Dept., Faculty of Agriculture, Ain Shams University, Cairo (Egypt); EL-NASHABY, F M; ALI, H G.M.; EL-SHIEMY, S M [Nuclear Research Centre, Atomic Energy Authority, Cairo (Egypt)

    2008-07-01

    The present investigation was carried out to establish the electron spin resonance (ESR) detection method for identifying irradiated nuts (almond and pistachio). Samples were irradiated with 2, 4 and 6 kGy and stored at room temperature (25{+-} 2{sup 0}C) for six months to study the possibility of detecting its previous irradiation treatments by ESR spectroscopy. Analysis was carried out just after irradiation treatment and during ambient storage period. The ESR signal intensities of irradiated samples were markedly increased correspondingly with irradiation dose as a result of free radicals generated by gamma irradiation so, all irradiated samples under investigation could be differentiated from non-irradiated ones immediately after irradiation treatment. The decay in radicals responsible of ESR signals showed the identification of irradiated almond (shell or edible part) and pistachio (edible part) was impossible after six months of ambient storage.

  15. DETECTION OF SOME IRRADIATED NUTS BY ELECTRON SPIN RESONANCE (ESR) TECHNIQUE

    International Nuclear Information System (INIS)

    KHALLAF, M.F.; YASIN, N.M.N.; EL-NASHABY, F.M.; ALI, H.G.M.; EL-SHIEMY, S.M.

    2008-01-01

    The present investigation was carried out to establish the electron spin resonance (ESR) detection method for identifying irradiated nuts (almond and pistachio). Samples were irradiated with 2, 4 and 6 kGy and stored at room temperature (25± 2 0 C) for six months to study the possibility of detecting its previous irradiation treatments by ESR spectroscopy. Analysis was carried out just after irradiation treatment and during ambient storage period. The ESR signal intensities of irradiated samples were markedly increased correspondingly with irradiation dose as a result of free radicals generated by gamma irradiation so, all irradiated samples under investigation could be differentiated from non-irradiated ones immediately after irradiation treatment. The decay in radicals responsible of ESR signals showed the identification of irradiated almond (shell or edible part) and pistachio (edible part) was impossible after six months of ambient storage

  16. Analysis of γ-ray irradiated pasteurized agaricus (Agaricus blazei Murill) by ESR in oxygen-free atmosphere

    International Nuclear Information System (INIS)

    Kemeya, Hiromi; Ukai, Mitsuko

    2007-01-01

    Agaricus (Agaricus blazei Murill) is one of a popular crude drug in Japan and East Asia countries. The crude drugs originating from natural raw products are easy to be contaminated by microorganism. Radiation method has been introduced as the sterilization technology for crude drugs. ESR has been used for the detection of radicals in irradiated drugs. Using ESR, we detected radical species in Agaricus before and after the gamma ray pasteurization. The ESR spectrum consists of a broad sextet centered at g=2.0, a singlet at same g-value and a singlet at g=4.0. We found that relaxation times of radicals in Agaricus varied by the presence of oxygen. Upon substitution of air by Ar, i.e., the absent of oxygen in the ESR sample tube, the T 1 value became 10 times larger than the presence of oxygen. Accordingly, the progressive saturation curve indicates more immediate saturation under the Ar than air atmosphere. Radicals, produced by the γ-ray irradiation to Agaricus, are very sensitive to oxygen. We concluded that ESR spectrum of irradiated Agaricus sample in the absence of oxygen is useful for the detection of dose level of γ-ray irradiation. (author)

  17. Time-dependent first-principles study of angle-resolved secondary electron emission from atomic sheets

    Science.gov (United States)

    Ueda, Yoshihiro; Suzuki, Yasumitsu; Watanabe, Kazuyuki

    2018-02-01

    Angle-resolved secondary electron emission (ARSEE) spectra were analyzed for two-dimensional atomic sheets using a time-dependent first-principles simulation of electron scattering. We demonstrate that the calculated ARSEE spectra capture the unoccupied band structure of the atomic sheets. The excitation dynamics that lead to SEE have also been revealed by the time-dependent Kohn-Sham decomposition scheme. In the present study, the mechanism for the experimentally observed ARSEE from atomic sheets is elucidated with respect to both energetics and the dynamical aspects of SEE.

  18. Studies of Minerals, Organic and Biogenic Materials through Time-Resolved Raman Spectroscopy

    Science.gov (United States)

    Garcia, Christopher S.; Abedin, M. Nurul; Ismail, Syed; Sharma, Shiv K.; Misra, Anupam K.; Nyugen, Trac; Elsayed-Ali, hani

    2009-01-01

    A compact remote Raman spectroscopy system was developed at NASA Langley Research center and was previously demonstrated for its ability to identify chemical composition of various rocks and minerals. In this study, the Raman sensor was utilized to perform time-resolved Raman studies of various samples such as minerals and rocks, Azalea leaves and a few fossil samples. The Raman sensor utilizes a pulsed 532 nm Nd:YAG laser as excitation source, a 4-inch telescope to collect the Raman-scattered signal from a sample several meters away, a spectrograph equipped with a holographic grating, and a gated intensified CCD (ICCD) camera system. Time resolved Raman measurements were carried out by varying the gate delay with fixed short gate width of the ICCD camera, allowing measurement of both Raman signals and fluorescence signals. Rocks and mineral samples were characterized including marble, which contain CaCO3. Analysis of the results reveals the short (approx.10-13 s) lifetime of the Raman process, and shows that Raman spectra of some mineral samples contain fluorescence emission due to organic impurities. Also analyzed were a green (pristine) and a yellow (decayed) sample of Gardenia leaves. It was observed that the fluorescence signals from the green and yellow leaf samples showed stronger signals compared to the Raman lines. Moreover, it was also observed that the fluorescence of the green leaf was more intense and had a shorter lifetime than that of the yellow leaf. For the fossil samples, Raman shifted lines could not be observed due the presence of very strong short-lived fluorescence.

  19. Prospective time-resolved LCA of fully electric supercap vehicles in Germany.

    Science.gov (United States)

    Zimmermann, Benedikt M; Dura, Hanna; Baumann, Manuel J; Weil, Marcel R

    2015-07-01

    The ongoing transition of the German electricity supply toward a higher share of renewable and sustainable energy sources, called Energiewende in German, has led to dynamic changes in the environmental impact of electricity over the last few years. Prominent scenario studies predict that comparable dynamics will continue in the coming decades, which will further improve the environmental performance of Germany's electricity supply. Life cycle assessment (LCA) is the methodology commonly used to evaluate environmental performance. Previous LCA studies on electric vehicles have shown that the electricity supply for the vehicles' operation is responsible for the major part of their environmental impact. The core question of this study is how the prospective dynamic development of the German electricity mix will affect the impact of electric vehicles operated in Germany and how LCA can be adapted to analyze this impact in a more robust manner. The previously suggested approach of time-resolved LCA, which is located between static and dynamic LCA, is used in this study and compared with several static approaches. Furthermore, the uncertainty issue associated with scenario studies is addressed in general and in relation to time-resolved LCA. Two scenario studies relevant to policy making have been selected, but a moderate number of modifications have been necessary to adapt the data to the requirements of a life cycle inventory. A potential, fully electric vehicle powered by a supercapacitor energy storage system is used as a generic example. The results show that substantial improvements in the environmental repercussions of the electricity supply and, consequentially, of electric vehicles will be achieved between 2020 and 2031 on the basis of the energy mixes predicted in both studies. This study concludes that although scenarios might not be able to predict the future, they should nonetheless be used as data sources in prospective LCA studies, because in many cases

  20. Thermal behaviour of the ESR Relaxation time in slightly dirty superconductors

    International Nuclear Information System (INIS)

    Schwachheim, G.; Machado, S.F.; Tsallis, C.

    1978-07-01

    The thermal behaviour of the ESR relaxation rate in slightly dirty superconductors is discussed for both exchange and spin-orbit interactions between the conduction electrons and the impurities. The sensibility to the electronic density of states is exhibited by using, in a modified BCS framework, an heuristic analytic form which avoids two of three defects of a previous similar treatment. The sudden increase (decrease) of the relaxation rate immediately below the critical temperature for the exchange (spin-orbit) case is confirmed. Reasonable agreement with experimental data in LaRu 2 ; Gd is obtained [pt

  1. Time-resolved Femtosecond Photon Echo Probes Bimodal Solvent Dynamics

    NARCIS (Netherlands)

    Pshenichnikov, M.S; Duppen, K.; Wiersma, D. A.

    1995-01-01

    We report on time-resolved femtosecond photon echo experiments of a dye molecule in a polar solution. The photon echo is time resolved by mixing the echo with a femtosecond gate pulse in a nonlinear crystal. It is shown that the temporal profile of the photon echo allows separation of the

  2. The analysis of time-resolved optically stimulated luminescence: I. Theoretical considerations

    International Nuclear Information System (INIS)

    Chithambo, M L

    2007-01-01

    This is the first of two linked papers on the analysis of time-resolved optically stimulated luminescence. This paper focusses on a theoretical basis of analytical methods and on methods for interpretation of time-resolved luminescence spectra and calculation of luminescence throughput. Using a comparative analysis of the principal features of time-resolved luminescence and relevant analogues from steady state optical stimulation, formulae for configuring a measurement system for optimum performance are presented. We also examine the possible use of stretched-exponential functions for analysis of time-resolved optically stimulated luminescence spectra

  3. Time-resolved studies at PETRA III with a highly repetitive synchronized laser system

    Energy Technology Data Exchange (ETDEWEB)

    Schlie, Mortiz

    2013-09-15

    Atomic and molecular processes can nowadays be directly followed in the time domain. This is a core technique for a better understanding of the involved fundamental physics, thus auguring new applications in the future as well. Usually the so-called pump-probe technique making use of two synchronized ultrashort light pulses is utilized to obtain this time-resolved data. In this work, the development and characterization of a synchronization system enabling such pump-probe studies at the storage ring PETRA III in combination with an external, then synchronized fs-laser system is described. The synchronization is based on an extended PLL approach with three interconnected feedback loops allowing to monitor short-time losses of the lock and thus prevent them. This way, the jitter between the laser PHAROS and the PETRA III reference signal is reduced to {sigma} <5 ps. Thus the system allows to conduct experiments at a repetition rate of 130 kHz with a temporal resolution limited only by the X-ray pulse length. A major emphasis in the fundamental introductory chapters is an intuitive explanation of the basic principles of phase locked loops and the different aspects of phase noise to allow a deeper understanding of the synchronization. Furthermore, first pump-probe experiments conducted at different beamlines at PETRA III are presented, demonstrating the usability of the laser system in a scientific environment as well. In first characterizing experiments the pulse duration of PETRA III X-ray pulses has been measured to be 90 ps FWHM. In particular, there have been time resolved X-ray absorption spectroscopy experiments on Gaq3 and Znq2 conducted at beamline P11. First results show dynamics of the electronic excitation on the timescale of a few hundred pico seconds up to a few nano seconds and provide a basic understanding for further research on those molecules. For Gaq3 this data is analyzed in detail and compared with visible fluorescence measurements suggesting at

  4. Time-resolved studies at PETRA III with a highly repetitive synchronized laser system

    International Nuclear Information System (INIS)

    Schlie, Mortiz

    2013-09-01

    Atomic and molecular processes can nowadays be directly followed in the time domain. This is a core technique for a better understanding of the involved fundamental physics, thus auguring new applications in the future as well. Usually the so-called pump-probe technique making use of two synchronized ultrashort light pulses is utilized to obtain this time-resolved data. In this work, the development and characterization of a synchronization system enabling such pump-probe studies at the storage ring PETRA III in combination with an external, then synchronized fs-laser system is described. The synchronization is based on an extended PLL approach with three interconnected feedback loops allowing to monitor short-time losses of the lock and thus prevent them. This way, the jitter between the laser PHAROS and the PETRA III reference signal is reduced to σ <5 ps. Thus the system allows to conduct experiments at a repetition rate of 130 kHz with a temporal resolution limited only by the X-ray pulse length. A major emphasis in the fundamental introductory chapters is an intuitive explanation of the basic principles of phase locked loops and the different aspects of phase noise to allow a deeper understanding of the synchronization. Furthermore, first pump-probe experiments conducted at different beamlines at PETRA III are presented, demonstrating the usability of the laser system in a scientific environment as well. In first characterizing experiments the pulse duration of PETRA III X-ray pulses has been measured to be 90 ps FWHM. In particular, there have been time resolved X-ray absorption spectroscopy experiments on Gaq3 and Znq2 conducted at beamline P11. First results show dynamics of the electronic excitation on the timescale of a few hundred pico seconds up to a few nano seconds and provide a basic understanding for further research on those molecules. For Gaq3 this data is analyzed in detail and compared with visible fluorescence measurements suggesting at least

  5. Thin film growth studies using time-resolved x-ray scattering

    Science.gov (United States)

    Kowarik, Stefan

    2017-02-01

    Thin-film growth is important for novel functional materials and new generations of devices. The non-equilibrium growth physics involved is very challenging, because the energy landscape for atomic scale processes is determined by many parameters, such as the diffusion and Ehrlich-Schwoebel barriers. We review the in situ real-time techniques of x-ray diffraction (XRD), x-ray growth oscillations and diffuse x-ray scattering (GISAXS) for the determination of structure and morphology on length scales from Å to µm. We give examples of time resolved growth experiments mainly from molecular thin film growth, but also highlight growth of inorganic materials using molecular beam epitaxy (MBE) and electrochemical deposition from liquids. We discuss how scaling parameters of rate equation models and fundamental energy barriers in kinetic Monte Carlo methods can be determined from fits of the real-time x-ray data.

  6. Development of multi-frequency ESR system for high-pressure measurements up to 2.5 GPa

    Science.gov (United States)

    Sakurai, T.; Fujimoto, K.; Matsui, R.; Kawasaki, K.; Okubo, S.; Ohta, H.; Matsubayashi, K.; Uwatoko, Y.; Tanaka, H.

    2015-10-01

    A new piston-cylinder pressure cell for electron spin resonance (ESR) has been developed. The pressure cell consists of a double-layer hybrid-type cylinder with internal components made of the ZrO2-based ceramics. It can generate a pressure of 2 GPa repeatedly and reaches a maximum pressure of around 2.5 GPa. A high-pressure ESR system using a cryogen-free superconducting magnet up 10 T has also been developed for this hybrid-type pressure cell. The frequency region is from 50 GHz to 400 GHz. This is the first time a pressure above 2 GPa has been achieved in multi-frequency ESR system using a piston-cylinder pressure cell. We demonstrate its potential by showing the results of the high-pressure ESR of the S = 1 system with the single ion anisotropy NiSnCl6 · 6H2O and the S = 1 / 2 quantum spin system CsCuCl3. We performed ESR measurements of these systems above 2 GPa successfully.

  7. Multiple and Periodic Measurement of RBC Aggregation and ESR in Parallel Microfluidic Channels under On-Off Blood Flow Control

    Directory of Open Access Journals (Sweden)

    Yang Jun Kang

    2018-06-01

    Full Text Available Red blood cell (RBC aggregation causes to alter hemodynamic behaviors at low flow-rate regions of post-capillary venules. Additionally, it is significantly elevated in inflammatory or pathophysiological conditions. In this study, multiple and periodic measurements of RBC aggregation and erythrocyte sedimentation rate (ESR are suggested by sucking blood from a pipette tip into parallel microfluidic channels, and quantifying image intensity, especially through single experiment. Here, a microfluidic device was prepared from a master mold using the xurography technique rather than micro-electro-mechanical-system fabrication techniques. In order to consider variations of RBC aggregation in microfluidic channels due to continuous ESR in the conical pipette tip, two indices (aggregation index (AI and erythrocyte-sedimentation-rate aggregation index (EAI are evaluated by using temporal variations of microscopic, image-based intensity. The proposed method is employed to evaluate the effect of hematocrit and dextran solution on RBC aggregation under continuous ESR in the conical pipette tip. As a result, EAI displays a significantly linear relationship with modified conventional ESR measurement obtained by quantifying time constants. In addition, EAI varies linearly within a specific concentration of dextran solution. In conclusion, the proposed method is able to measure RBC aggregation under continuous ESR in the conical pipette tip. Furthermore, the method provides multiple data of RBC aggregation and ESR through a single experiment. A future study will involve employing the proposed method to evaluate biophysical properties of blood samples collected from cardiovascular diseases.

  8. Study Of Soot Growth And Nucleation By A Time-Resolved Synchrotron Radiation Based X-Ray Absorption Method

    National Research Council Canada - National Science Library

    Mitchell, Judith I

    2001-01-01

    This report results from a contract tasking University of Rennes I as follows: The contractor will perform a study of soot growth and nucleation by a time-resolved synchrotron radiation based x-ray absorption method...

  9. A method to improve application technique in Alanine/ESR dosimetry

    International Nuclear Information System (INIS)

    Choi, Hoon; Ha, Ju Hee; Choi, Won; Lim, Young Khi

    2008-01-01

    Full text: For long-term radiation monitoring to assess the cable aging in harsh condition of nuclear power plant, ESR dosimetry method using alanine dosimeters was already recommended in many technical document and paper. Several ESR dosimetry systems were already produced and used widely, but the actual application of these systems for industrial dosimetry needs careful consideration of error sources in process of dose measurement. The alanine dosimeters were measured by E-scan alanine analyzer system or EMX ESR spectrometer. For the accurate measurement of the dosimeters, we have studied various source of errors. First, this paper discusses sources of inaccuracy related to data processing. To make a meaningful dose assessment, the dosimeter measurements need to be compared with measurements made using certified dosimeters of known dose. This is achieved by performing the routine calibration procedure which creates a calibration curve and corresponding fit coefficients from measurements made with a set of dosimeters with known certified dose. The calibration curves in ESR dosimetry are usually constructed by means of the least-squares technique in its simplest variant. The recommended alternative linearity several replicate measurements of Y at each used X value. Also, measurement is subject to error, so repeat measurements will not be identical. A technical description of a linear calibration is assumed that the dispersion of the measurements is the same for each standard. But in some cases, the standard deviation has to be specified separately for each value of concentration. In this case, it used the WLS (Weighted Least-Squared Regression) method instead of the OLS (Ordinary Least-Squared Regression) method. Second, the precision of the ESR spectrum was showed as a reproducibility test for the two ESR systems. The reproducibility test was performed at an absorbed dose of 1 k Gy, which is at least three orders of magnitude above the background reading of an

  10. Time-Resolved Emission Spectroscopic Study of Laser-Induced Steel Plasmas

    International Nuclear Information System (INIS)

    Shah, M. L.; Pulhani, A. K.; Suri, B. M.; Gupta, G. P.

    2013-01-01

    Laser-induced steel plasma is generated by focusing a Q-switched Nd:YAG visible laser (532 nm wavelength) with an irradiance of ∼ 1 × 10 9 W/cm 2 on a steel sample in air at atmospheric pressure. An Echelle spectrograph coupled with a gateable intensified charge-coupled detector is used to record the plasma emissions. Using time-resolved spectroscopic measurements of the plasma emissions, the temperature and electron number density of the steel plasma are determined for many times of the detector delay. The validity of the assumption by the spectroscopic methods that the laser-induced plasma (LIP) is optically thin and is also in local thermodynamic equilibrium (LTE) has been evaluated for many delay times. From the temporal evolution of the intensity ratio of two Fe I lines and matching it with its theoretical value, the delay times where the plasma is optically thin and is also in LTE are found to be 800 ns, 900 ns and 1000 ns.

  11. Time-resolved fluorescence analysis of the mobile flavin cofactor

    Indian Academy of Sciences (India)

    Conformational heterogeneity of the FAD cofactor in -hydroxybenzoate hydroxylase (PHBH) was investigated with time-resolved polarized flavin fluorescence. For binary enzyme/substrate (analogue) complexes of wild-type PHBH and Tyr222 mutants, crystallographic studies have revealed two distinct flavin conformations ...

  12. Hole emission from Ge/Si quantum dots studied by time-resolved capacitance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kapteyn, C.M.A.; Lion, M.; Heitz, R.; Bimberg, D. [Technische Univ. Berlin (Germany). Inst. fuer Festkoerperphysik; Miesner, C.; Asperger, T.; Brunner, K.; Abstreiter, G. [Technische Univ. Muenchen, Garching (Germany). Walter-Schottky-Inst. fuer Physikalische Grundlagen der Halbleiterelektronik

    2001-03-01

    Emission of holes from self-organized Ge quantum dots (QDs) embedded in Si Schottky diodes is studied by time-resolved capacitance spectroscopy (DLTS). The DLTS signal is rather broad and depends strongly on the filling and detection bias conditions. The observed dependence is interpreted in terms of carrier emission from many-hole states of the QDs. The activation energies obtained from the DLTS measurements are a function of the amount of stored charge and the position of the Fermi level in the QDs. (orig.)

  13. ESR identification of gamma-irradiated albendazole

    Science.gov (United States)

    Çolak, Seyda

    2010-01-01

    The use of ionizing radiation for sterilization of pharmaceuticals is a well-established technology. In the present work, the spectroscopic and kinetic features of the radicals induced in gamma-irradiated solid albendazole samples is investigated at different temperatures in the dose range of 3-34 kGy by electron spin resonance (ESR) spectroscopy. Irradiation with gamma radiation produced two different radical species in albendazole. They were fairly stable at room temperature but relatively unstable above room temperature, giving rise to an unresolved ESR spectrum consisting of three resonance peaks centered at g=2.0057. Decay activation energies of the contributing radical species were calculated to be 47.8 (±13.5) and 50.5 (±9.7) kJ/mol using the signal intensity decay data derived from annealing studies performed at high temperatures. A linear function of the applied dose was found to best describe the experimental dose-response data. Albendazole does not present the characteristics of good dosimetric materials. However, the discrimination of irradiated albendazole from its unirradiated form was possible even 6 months after storage in normal conditions. Based on these findings, it is concluded that albendazole and albendazole-containing drugs can be safely sterilized by gamma radiation and that ESR spectroscopy could be successfully used as a potential technique for monitoring their radiosterilization.

  14. NO kinetics in pulsed low-pressure nitrogen plasmas studied by time resolved quantum cascade laser absorption spectroscopy

    NARCIS (Netherlands)

    Welzel, S.; Guaitella, O.; Lazzaroni, C.; Pintassilgo, C.; Rousseau, A.; Röpcke, J.

    2011-01-01

    Time-resolved quantum cascade laser absorption spectroscopy at 1897 cm-1 (5.27 µm) has been applied to study the NO(X) kinetics on the micro- and millisecond time scale in pulsed low-pressure N2/NO dc discharges. Experiments have been performed under flowing and static gas conditions to infer the

  15. Quantitative detection of absorbed dose of irradiated dried fruit by ESR spectroscopy method

    International Nuclear Information System (INIS)

    Li Weiming; Ha Yiming; Zhao Yongfu; Zhang Yanli

    2011-01-01

    Sunflower seeds, walnuts, pistachios, and hazelnuts were used as experimental materials which were irradiated at 1.0, 3.0, 5.0 and 10.0 kGy, respectively. The relationships and correlations between ESR signal intensity and irradiation dosages were studied. The results showed that ESR spectra of irradiated samples were obviously different from that of CK, and the ESR signal intensity was positively related with the irradiation dose. After irradiation, the ESR intensity and spectrum shapes all changed and all four samples were clearly identified irradiated or unirradiated. The appearances of the two weak satellite lines which situated left and right to the intense singlet line in walnuts and pistachios proved the existence of cellulose radical. The detection dose limit of irradiated walnut was 1 kGy, and the detection limits of the other three samples were lower than 1 kGy. In conclusion, the ESR method could be used to irradiated. (authors)

  16. Evolution of ESR Technology and Equipment for Long Hollow Ingots Manufacture

    Science.gov (United States)

    Medovar, Lev; Stovpchenko, Ganna; Dudka, Grigory; Kozminskiy, Alexander; Fedorovskii, Borys; Lebid, Vitalii; Gusiev, Iaroslav

    In this paper development of both ESR technology and equipment for hollow ingot manufacture review and analysis are presented. The real complications of hollow ingot manufacture and some tendentious issues which restrict process dissemination are discussed. An actual data of modern manufacture of as-cast pipes for heat and power engineering by traditional ESR with consumable electrode are given. Results of microstructure and nonmetal inclusion investigations have shown the high quality of as-cast ESR pipes. On the basis of these results the possibility to produce huge ESR hollows (up 5000 mm in dia) with final goal drastically to reduce setting ratio on forged shells and rings or even replace it by ESR hollows as-cast is grounded. Two new ESR technologies — consumable electrodes change and liquid metal usage — have passed pilot tests for heavy hollow production and shown very prospective results to be presented.

  17. Time Resolved Studies of Carrier Dynamics in III -v Heterojunction Semiconductors.

    Science.gov (United States)

    Westland, Duncan James

    Available from UMI in association with The British Library. Requires signed TDF. Picosecond time-resolution photoluminescence spectroscopy has been used to study transient processes in Ga _{.47}In_{.53 }As/InP multiple quantum wells (MQWs), and in bulk Ga_{.47}In _{.53}As and GaSb. To facilitate the experimental studies, apparatus was constructed to allow the detection of transient luminescence with 3ps time resolution. A frequency upconversion technique was employed. Relaxation of energetic carriers in bulk Ga _{.47}In_{.53 }As by optic phonons has been investigated, and, at carrier densities ~3 times 10^{18}cm ^{-3} is found to be a considerably slower process than simple theory predicts. The discrepancy is resolved by the inclusion of a non-equilibrium population of longitudinal optic phonons in the theoretical description. Slow energy loss is also observed in a 154A MQW under similar conditions, but carriers are found to relax more quickly in a 14A MQW with a comparable repeat period. The theory of non-equilibrium mode occupation is modified to describe the case of a MQW and is found to agree with experiment. Carrier relaxation in GaSb is studied and the importance of occupation of the L _6 conduction band valley in this material is demonstrated. The ambipolar diffusion of a photoexcited carrier plasma through an InP capping layer was investigated using an optical time-of-flight technique. This experiment also enables the efficiency of carrier capture by a Ga _{.47}In_{.53 }As quantum well to be determined. A capture time of 4ps was found.

  18. An Endogenous Electron Spin Resonance (ESR signal discriminates nevi from melanomas in human specimens: a step forward in its diagnostic application.

    Directory of Open Access Journals (Sweden)

    Eleonora Cesareo

    Full Text Available Given the specific melanin-associated paramagnetic features, the Electron Spin Resonance (ESR, called also Electron Paramagnetic Resonance, EPR analysis has been proposed as a potential tool for non-invasive melanoma diagnosis. However, studies comparing human melanoma tissues to the most appropriate physiological counterpart (nevi have not been performed, and ESR direct correlation with melanoma clinical features has never been investigated. ESR spectrum was obtained from melanoma and non-melanoma cell-cultures as well as mouse melanoma and non-melanoma tissues and an endogenous ESR signal (g = 2.005 was found in human melanoma cells and in primary melanoma tissues explanted from mice, while it was always absent in non-melanoma samples. These characteristics of the measured ESR signal strongly suggested its connection with melanin. Quantitative analyses were then performed on paraffin-embedded human melanoma and nevus sections, and validated on an independent larger validation set, for a total of 112 sections (52 melanomas, 60 nevi. The ESR signal was significantly higher in melanomas (p = 0.0002 and was significantly different between "Low Breslow's and "High Breslow's" depth melanomas (p<0.0001. A direct correlation between ESR signal and Breslow's depth, expressed in millimetres, was found (R = 0.57; p<0.0001. The eu/pheomelanin ratio was found to be significantly different in melanomas "Low Breslow's" vs melanomas "High Breslow's" depth and in nevi vs melanomas "High Breslow's depth". Finally, ROC analysis using ESR data discriminated melanomas sections from nevi sections with up to 90% accuracy and p<0.0002. In the present study we report for the first time that ESR signal in human paraffin-embedded nevi is significantly lower than signal in human melanomas suggesting that spectrum variations may be related to qualitative melanin differences specifically occurring in melanoma cells. We therefore conclude that this ESR signal

  19. Spectral and time-resolved studies on ocular structures

    Science.gov (United States)

    Schweitzer, D.; Jentsch, S.; Schenke, S.; Hammer, M.; Biskup, C.; Gaillard, E.

    2007-07-01

    Measurements of endogeous fluorophores open the possibility for evaluation of metabolic state at the eye. For interpretation of 2-dimensional measurements of time-resolved auto fluorescence in 2 separate spectral ranges at the human eye, comparing measurements were performed on porcine eyes. Determining excitation and emission spectra, attention was drawn of proof of coenzymes NADH and FAD in isolated anatomical structures cornea, aqueous humor, lens, vitreous, neuronal retina, retinal pigment epithelium (RPE), choroid, and sclera. All these structures exhibit auto fluorescence, highest in lens. Excitation at 350 nm results in local fluorescence maxima at 460 nm, corresponding to NADH, in all structures. This short-wave excitation allows metabolic studies only at the anterior eye, because of the limited transmission of the ocular media. During excitation at 446 nm the existence of FAD is expressed by local fluorescence maxima at 530 nm. The composition fluorescence spectra allow no discrimination between single ocular structures. Approximating the dynamic fluorescence by a double exponential function, the shortest lifetimes were detected in RPE and neuronal retina. The histograms of mean lifetime t M cover each other on lens with cornea and also on sclera with choroid. Despite the lifetimes are close between RPE and neuronal retina, the relative contributions Q I are wide different. The gradient of trend lines in cluster diagrams of amplitudes α II vs. α I allows a discrimination of ocular structures.

  20. Watching proteins function with time-resolved x-ray crystallography

    Science.gov (United States)

    Šrajer, Vukica; Schmidt, Marius

    2017-09-01

    Macromolecular crystallography was immensely successful in the last two decades. To a large degree this success resulted from use of powerful third generation synchrotron x-ray sources. An expansive database of more than 100 000 protein structures, of which many were determined at resolution better than 2 Å, is available today. With this achievement, the spotlight in structural biology is shifting from determination of static structures to elucidating dynamic aspects of protein function. A powerful tool for addressing these aspects is time-resolved crystallography, where a genuine biological function is triggered in the crystal with a goal of capturing molecules in action and determining protein kinetics and structures of intermediates (Schmidt et al 2005a Methods Mol. Biol. 305 115-54, Schmidt 2008 Ultrashort Laser Pulses in Biology and Medicine (Berlin: Springer) pp 201-41, Neutze and Moffat 2012 Curr. Opin. Struct. Biol. 22 651-9, Šrajer 2014 The Future of Dynamic Structural Science (Berlin: Springer) pp 237-51). In this approach, short and intense x-ray pulses are used to probe intermediates in real time and at room temperature, in an ongoing reaction that is initiated synchronously and rapidly in the crystal. Time-resolved macromolecular crystallography with 100 ps time resolution at synchrotron x-ray sources is in its mature phase today, particularly for studies of reversible, light-initiated reactions. The advent of the new free electron lasers for hard x-rays (XFELs; 5-20 keV), which provide exceptionally intense, femtosecond x-ray pulses, marks a new frontier for time-resolved crystallography. The exploration of ultra-fast events becomes possible in high-resolution structural detail, on sub-picosecond time scales (Tenboer et al 2014 Science 346 1242-6, Barends et al 2015 Science 350 445-50, Pande et al 2016 Science 352 725-9). We review here state-of-the-art time-resolved crystallographic experiments both at synchrotrons and XFELs. We also outline

  1. A 3D- and 4D-ESR imaging system for small animals

    International Nuclear Information System (INIS)

    Oikawa, K.; Ogata, T.; Togashi, H.; Yokoyama, H.; Ohya-Nishiguchi, H.; Kamada, H.

    1996-01-01

    A new version of in vivo ESR-CT system composed of custom-made 0.7 GHz ESR spectrometer, air-core magnet with a field-scanning coil, three field-gradient coils, and two computers enables up-and down-field, and rapid magnetic-field scanning linearly controlled by computer. 3D-pictures of distribution of nitroxide radicals injected in brains and livers of rats and mice were obtained in 1.5 min with resolution of 1 mm. We have also succeeded in obtaining spatial-time imagings of the animals. (author)

  2. Femtosecond Time-resolved Optical Polarigraphy (FTOP)

    International Nuclear Information System (INIS)

    Aoshima, S.; Fujimoto, M.; Hosoda, M.; Tsuchiya, Y.

    2000-01-01

    A novel time-resolved imaging technique named FTOP (Femtosecond Time-resolved Optical Polarigraphy) for visualizing the ultrafast propagation dynamics of intense light pulses in a medium has been proposed and demonstrated. Femtosecond snapshot images can be created with a high spatial resolution by imaging only the polarization components of the probe pulse; these polarization components change due to the instantaneous birefringence induced by the pump pulse in the medium. Ultrafast temporal changes in the two-dimensional spatial distribution of the optical pulse intensity were clearly visualized in consecutive images by changing the delay between the pump and probe. We observe that several filaments appear and then come together before the vacuum focus due to nonlinear effects in air. We also prove that filamentation dynamics such as the formation position and the propagation behavior are complex and are strongly affected by the pump energy. The results collected clearly show that this method FTOP succeeds for the first time in directly visualizing the ultrafast dynamics of the self-modulated nonlinear propagation of light. (author)

  3. ESR teleradiology survey: results.

    Science.gov (United States)

    2016-08-01

    With recent developments of teleradiology technology and services, it has become necessary to better evaluate its extent and use among different countries in Europe. With this goal in mind, the ESR launched two specific surveys intended to gather the current state of adoption and implementation of teleradiology in clinical practice. A special focus on differentiating between insourcing teleradiology services among partners of the same organisation and outsourcing to external services was an essential part of the design of these surveys. The first survey was addressed to 44 national societies of different countries in Europe, while the second survey was intended for all practicing radiologist ESR members. While the results of these surveys reported here may provide a wealth of information to better understand the trends in adoption of teleradiology in Europe, they only represent a snapshot at a certain point in time. The rapid development of telecommunication tools as well as a fundamental change in practice and healthcare economics will certainly influence these observations in the upcoming years. These data, however, will provide objective and relevant parameters for supporting the efforts of experts and policy makers in promoting appropriate criteria and guidelines for adequate use of teleradiology in clinical practice. Main Messages • Understand concepts and challenges of teleradiology • Provide insight into current trends and solutions for teleradiology • Compare differences in teleradiolgy strategies between countries in Europe • Establish a reference on statistical data of usage of teleradiology in Europe.

  4. Time-resolved small-angle neutron scattering study on soap-free emulsion polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Motokawa, Ryuhei [Research Group of Soft Matter and Neutron Scattering, Advanced Science Research Center, Japan Atomic Energy Research Institute, Tokai, Ibaraki 319-1195 (Japan); Koizumi, Satoshi [Research Group of Soft Matter and Neutron Scattering, Advanced Science Research Center, Japan Atomic Energy Research Institute, Tokai, Ibaraki 319-1195 (Japan)]. E-mail: koizumi@neutrons.tokai.jaeri.go.jp; Hashimoto, Takeji [Research Group of Soft Matter and Neutron Scattering, Advanced Science Research Center, Japan Atomic Energy Research Institute, Tokai, Ibaraki 319-1195 (Japan); Nakahira, Takayuki [Department of Applied Chemistry and Biotechnology, Chiba University, Chiba-shi, Chiba 263-8522 (Japan); Annaka, Masahiko [Department of Chemistry, Kyushu University, Fukuoka 812-8581 (Japan)

    2006-11-15

    We investigated an aqueous soap-free emulsion polymerization process of Poly(N-isopropylacrylamide)-block-poly(ethylene glycol) by ultra-small-angle and time-resolved small-angle neutron scattering methods. The results indicate that the compartmentalization of chain end radicals into solid-like micelle cores crucially leads to the quasi-living behavior of the radical polymerization by prohibiting recombination process.

  5. Thermo-oxidative degradation study of melt-processed polyethylene and its blend with polyamide using time-resolved rheometry

    CSIR Research Space (South Africa)

    Salehiyan, Reza

    2017-05-01

    Full Text Available Time-resolved mechanical spectroscopy (TRMS) was conducted to study the thermo-oxidative degradation of linear low density polyethylene (LLDPE) samples with different thermal histories and their blends with a polyamide (PA6) in the melt state. Neat...

  6. Computation of ESR spectra from the time evolution of the magnetization : Comparison of autocorrelation and Wiener-Khinchin-relation-based methods

    NARCIS (Netherlands)

    Ikeuchi, Hiroki; De Raedt, Hans; Bertaina, Sylvain; Miyashita, Seiji

    2015-01-01

    The calculation of finite temperature electron spin resonance (ESR) spectra for concrete specified crystal configurations is a very important issue in the study of quantum spin systems. Although direct evaluation of the Kubo formula by means of numerical diagonalization yields exact results, memory

  7. A time-resolved image sensor for tubeless streak cameras

    Science.gov (United States)

    Yasutomi, Keita; Han, SangMan; Seo, Min-Woong; Takasawa, Taishi; Kagawa, Keiichiro; Kawahito, Shoji

    2014-03-01

    This paper presents a time-resolved CMOS image sensor with draining-only modulation (DOM) pixels for tube-less streak cameras. Although the conventional streak camera has high time resolution, the device requires high voltage and bulky system due to the structure with a vacuum tube. The proposed time-resolved imager with a simple optics realize a streak camera without any vacuum tubes. The proposed image sensor has DOM pixels, a delay-based pulse generator, and a readout circuitry. The delay-based pulse generator in combination with an in-pixel logic allows us to create and to provide a short gating clock to the pixel array. A prototype time-resolved CMOS image sensor with the proposed pixel is designed and implemented using 0.11um CMOS image sensor technology. The image array has 30(Vertical) x 128(Memory length) pixels with the pixel pitch of 22.4um. .

  8. Time-resolved electron transport in quantum-dot systems; Zeitaufgeloester Elektronentransport in Quantendotsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Croy, Alexander

    2010-06-30

    In this thesis the time-resolved electron transport in quantum dot systems was studied. For this two different formalisms were presented: The nonequilibrium Green functions and the generalized quantum master equations. For both formalisms a propagation method for the numerical calculation of time-resolved expectation values, like the occupation and the electron current, was developed. For the demonstration of the propagation method two different question formulations were considered. On the one hand the stochastically driven resonant-level model was studied. On the other hand the pulse-induced transport through a double quantum dot was considered.

  9. Finite-difference time-domain analysis of time-resolved terahertz spectroscopy experiments

    DEFF Research Database (Denmark)

    Larsen, Casper; Cooke, David G.; Jepsen, Peter Uhd

    2011-01-01

    In this paper we report on the numerical analysis of a time-resolved terahertz (THz) spectroscopy experiment using a modified finite-difference time-domain method. Using this method, we show that ultrafast carrier dynamics can be extracted with a time resolution smaller than the duration of the T...

  10. Applying Costs, Risks and Values Evaluation (CRAVE) methodology to Engineering Support Request (ESR) prioritization

    Science.gov (United States)

    Joglekar, Prafulla N.

    1994-01-01

    Given limited budget, the problem of prioritization among Engineering Support Requests (ESR's) with varied sizes, shapes, and colors is a difficult one. At the Kennedy Space Center (KSC), the recently developed 4-Matrix (4-M) method represents a step in the right direction as it attempts to combine the traditional criteria of technical merits only with the new concern for cost-effectiveness. However, the 4-M method was not adequately successful in the actual prioritization of ESRs for the fiscal year 1995 (FY95). This research identifies a number of design issues that should help us to develop better methods. It emphasizes that given the variety and diversity of ESR's one should not expect that a single method could help in the assessment of all ESR's. One conclusion is that a methodology such as Costs, Risks, and Values Evaluation (CRAVE) should be adopted. It also is clear that the development of methods such as 4-M requires input not only from engineers with technical expertise in ESR's but also from personnel with adequate background in the theory and practice of cost-effectiveness analysis. At KSC, ESR prioritization is one part of the Ground Support Working Teams (GSWT) Integration Process. It was discovered that the more important barriers to the incorporation of cost-effectiveness considerations in ESR prioritization lie in this process. The culture of integration, and the corresponding structure of review by a committee of peers, is not conducive to the analysis and confrontation necessary in the assessment and prioritization of ESR's. Without assistance from appropriately trained analysts charged with the responsibility to analyze and be confrontational about each ESR, the GSWT steering committee will continue to make its decisions based on incomplete understanding, inconsistent numbers, and at times, colored facts. The current organizational separation of the prioritization and the funding processes is also identified as an important barrier to the

  11. Charge recombination processes in minerals studied using optically stimulated luminescence and time-resolved exo-electrons

    International Nuclear Information System (INIS)

    Tsukamoto, Sumiko; Murray, Andrew; Ankjaergaard, Christina; Jain, Mayank; Lapp, Torben

    2010-01-01

    A time-resolved optically stimulated exo-electron (TR-OSE) measurement system has been developed using a Photon Timer attached to a gas-flow semi-proportional pancake electron detector within a Risoe TL/OSL reader. The decay rate of the exo-electron emission after the stimulation pulse depends on the probability of (1) escape of electrons into the detector gas from the conduction band by overcoming the work function of the material and (2) thermalization of electrons in the conduction band, and subsequent re-trapping/recombination. Thus, we expect the exo-electron signal to reflect the instantaneous electron concentration in the conduction band. In this study, TR-OSE and time-resolved optically stimulated luminescence (TR-OSL) were measured for the first time using quartz, K-feldspar and NaCl by stimulating the samples using pulsed blue LEDs at different temperatures between 50 and 250 0 C after beta irradiation and preheating to 280 0 C. The majority of TR-OSE signals from all the samples decayed much faster than TR-OSL signals irrespective of the stimulation temperatures. This suggests that the lifetime of OSL in these dosimeters arises mainly from the relaxation of an excited state of the recombination centre, rather than from residence time of an electron in the conduction band.

  12. Current topics in ESR dating

    International Nuclear Information System (INIS)

    Skinner, Anne R.

    2011-01-01

    After over 25 years, the use of electron spin resonance (ESR) is well-established in dating sites of geological, paleontological and archaeological interest. Like any scientific technique, there have been changes in understanding and in methodology. Improvements have not, however, changed the observation that external dose calculations are still a significant source of uncertainty in ages. Examples from Europe, Africa and the Americans illustrate this point. For Pradayrol Cave (France), the occupation age, 330 ka, is unchallenged, making this the oldest known Neanderthal site in France. For Roc de Marsal, also in France, on the other hand, discrepancies between TL and sedimentary dose rates imply substantial differences in interpretation. In the Western Egyptian Desert, where artifacts and datable material are not well-correlated, the dating results show consistency with expectations based on global climate change, even in deflated sites. Climate change is also the question in geological studies in the Bahamas where, despite concerns about cosmic dose history, ESR dates confirm other evidence for sea level changes. We show that an uncertain age is not the same as an impossible one.

  13. Regeneration of phenolic antioxidants from phenoxyl radicals: An ESR and electrochemical study of antioxidant hierarchy

    DEFF Research Database (Denmark)

    Jørgensen, Lars V.; Madsen, Helle L.; Thomsen, Marianne K.

    1999-01-01

    Radicals from the flavonoids quercetin, (+)-catechin, (+/-)-taxifolin and luteolin, and from all-rac-alpha-tocopherol have been generated electrochemically by one-electron oxidation in deaerated dimethylformamide (DMF), and characterised by electron spin resonance spectroscopy (ESR) after spin......-trapping by 5,5-dimethyl-1-pyrroline-N-oxide (DMPO). Simulations of the ESR spectrum based on estimated coupling constants of the spin-trapped quercetin radical, confirmed that this antioxidant radical is oxygen-centered. The complex mixture of radicals, quinoid intermediates and stable two-electron oxidation...

  14. Identification of irradiated pepper by ESR measurement

    International Nuclear Information System (INIS)

    Morishita, Norio; Kume, Tamikazu; Kawakami, Waichiro; Ishigaki, Isao

    1988-01-01

    The possibility of using electron spin resonance (ESR) for identification of irradiated black and white pepper was examined. The ESR spectra induced by irradiation with 10 kGy are clearly distinguishable from that of unirradiated samples. The intensity of signal induced by irradiation was markedly reduced during 2 weeks storage but it was slowly reduced on further storage. The difference of intensity between the irradiated and unirradiated samples can be distinguished after 13 weeks storage. In this experiment, ground black pepper, ground white pepper and whole white pepper can be identified after 13 weeks. On the other hand, whole black pepper cannot be identified after 8 weeks because of the variation of values. It suggests that the suitable method for sample preparation such as separation of pellicle of whole black pepper is required before ESR measurement. (author)

  15. Electron beam dose measurements with alanine/ESR dosimeter

    International Nuclear Information System (INIS)

    Rodrigues, O. Jr.; Galante, O.L.; Campos, L.L.

    2001-01-01

    When the aminoacid alanine, CH 3 -CH(NH 2 )-COOH, is exposed to radiation field, stable free radicals are produced. The predominant paramagnetic specie found at room temperature is the CH 3 -CH-COOH. Electron Spin Resonance - ESR is a technique used for quantification and analysis of radicals in solid and liquid samples. The evaluation of the amount of produced radicals can be associated with the absorbed dose . The alanine/ESR is an established dosimetry method employed for high doses evaluation, it presents good performance for X-rays, gamma, electrons, and protons radiation detection. The High Doses Dosimetry Laboratory of Ipen developed a dosimetric system based on alanina/ESR that presents good characteristics for use in gamma fields such as: wide dose range from 10 to 10 5 Gy, low fading, low uncertainty (<5%), no dose rate dependence and non-destructive ESR single readout. The detector is encapsulated in a special polyethylene tube that reduces the humidity problems and improves the mechanical resistance. The IPEN dosimeter was investigated for application in electron beam fields dosimetry

  16. Studies of nanostructures using time-resolved x-ray excited optical luminescence*

    International Nuclear Information System (INIS)

    Rosenberg, R.A.; Shenoy, G.K.; Smita, S.; Burda, C.; Sham, T.K.

    2004-01-01

    Full text:The scientific community is currently investing a great deal of effort into understanding the physics and chemistry of nanoscale structures. Synchrotron radiation techniques are being used to study the physical, electronic, and magnetic structure of nanosystems, albeit at a relatively large size (greater than 30 nm). A major challenge facing researchers is finding methods that can probe structures of the smallest scale (less than 10 nm). Optical luminescence has been shown to be directly sensitive to structures in this size range due to quantum confinement phenomena. X-ray-excited optical luminescence (XEOL) provides the capability to chemically map the sites responsible for producing low-energy (1-6 eV) fluorescence. By taking advantage of the time structure of the x-ray pulses at the Advanced Photon Source (70 ps wide, 153 ns separation), it also possible to determine the dynamic behavior of the states involved in the luminescence. In this paper we will present results of time-resolved XEOL experiments on various nanostructures including porous silicon, silicon nanowires, and CdSe nanodots

  17. Alignment of time-resolved data from high throughput experiments.

    Science.gov (United States)

    Abidi, Nada; Franke, Raimo; Findeisen, Peter; Klawonn, Frank

    2016-12-01

    To better understand the dynamics of the underlying processes in cells, it is necessary to take measurements over a time course. Modern high-throughput technologies are often used for this purpose to measure the behavior of cell products like metabolites, peptides, proteins, [Formula: see text]RNA or mRNA at different points in time. Compared to classical time series, the number of time points is usually very limited and the measurements are taken at irregular time intervals. The main reasons for this are the costs of the experiments and the fact that the dynamic behavior usually shows a strong reaction and fast changes shortly after a stimulus and then slowly converges to a certain stable state. Another reason might simply be missing values. It is common to repeat the experiments and to have replicates in order to carry out a more reliable analysis. The ideal assumptions that the initial stimulus really started exactly at the same time for all replicates and that the replicates are perfectly synchronized are seldom satisfied. Therefore, there is a need to first adjust or align the time-resolved data before further analysis is carried out. Dynamic time warping (DTW) is considered as one of the common alignment techniques for time series data with equidistant time points. In this paper, we modified the DTW algorithm so that it can align sequences with measurements at different, non-equidistant time points with large gaps in between. This type of data is usually known as time-resolved data characterized by irregular time intervals between measurements as well as non-identical time points for different replicates. This new algorithm can be easily used to align time-resolved data from high-throughput experiments and to come across existing problems such as time scarcity and existing noise in the measurements. We propose a modified method of DTW to adapt requirements imposed by time-resolved data by use of monotone cubic interpolation splines. Our presented approach

  18. ESR-spin trapping studies on the interaction between anthraquinone triplets and aromatic compounds

    International Nuclear Information System (INIS)

    Moger, G.; Rockenbauer, A.; Simon, P.

    1980-01-01

    The ESR spin trapping technique was used for the detection of transient C-centered radicals in the photochemical interaction between triplet anthraquinone and aromatic hydroperoxide and alcohol. (author)

  19. ESR signal features of 60Co γ-ray irradiated bone tissue and its dose response relationship

    International Nuclear Information System (INIS)

    Wu Ke; Sun Zunpu; Shi Yuanming

    1993-01-01

    Electron spin resonance (ESR) technique was used to study the radiation-induced ESR signal features of different paramagnetic species of 60 Co γ-ray irradiated bone tissue. The results showed that the intensity of an ESR signal at that the intensity of an ESR signal at g 2.0022 of human bones exposed to a dose range of 0-50 Gy had linear dose response relationships. The lower limit of detectable dose was about 2 Gy and the detecting error was about 10%. The signal was stable at room temperature during 60 days, and the effect of radiation dose rate of 0.5-8.0 Gy/min could be neglected. This signal was insensitive to microwave power and temperature, which was suitable for rapid and direct detection with ESR technique. These features suggest that human bones could be used for radiation accident dose evaluation by ESR

  20. Time-resolved materials science opportunities using synchrotron x-ray sources

    International Nuclear Information System (INIS)

    Larson, B.C.; Tischler, J.Z.

    1995-06-01

    The high brightness, high intensity, and pulsed time-structure of synchrotron sources provide new opportunities for time-resolved x-ray diffraction investigations. With third generation synchrotron sources coming on line, high brilliance and high brightness are now available in x-ray beams with the highest flux. In addition to the high average flux, the instantaneous flux available in synchrotron beams is greatly enhanced by the pulsed time structure, which consists of short bursts of x-rays that are separated by ∼tens to hundreds of nanoseconds. Time-resolved one- and two-dimensional position sensitive detection techniques that take advantage of synchrotron radiation for materials science x-ray diffraction investigations are presented, and time resolved materials science applications are discussed in terms of recent diffraction and spectroscopy results and materials research opportunities

  1. Quantum-dot-based homogeneous time-resolved fluoroimmunoassay of alpha-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Chen Meijun; Wu Yingsong; Lin Guanfeng; Hou Jingyuan; Li Ming [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou, 510515 (China); Liu Tiancai, E-mail: liutc@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou, 510515 (China)

    2012-09-05

    .4 ng mL{sup -1}. By assaying test samples against the standard curve, the coefficient of variations was <5%, indicating that QDs were suitable for this homogenous time-resolved fluoroimmunoassay. This work extended the potential applications of QDs in future homogeneous analytical bioassays. In the coming research, hepatitis B surface antigen, another primary marker for hepatocellular carcinoma, will be studied for practical detection using a QD-based homogenous multiplex fluoroimmunoassay.

  2. Dose determination in irradiated chicken meat by ESR method

    International Nuclear Information System (INIS)

    Polat, M.

    1996-01-01

    In this work, the properties of the radicals produced in chicken bones have been investigated by ESR technique to determine the amount of dose applied to the chicken meats during the food irradiation. For this goal, the drumsticks from 6-8 weeks old chickens purchased from a local market were irradiated at dose levels of 0; 2; 4; 6; 8 and 10 kGy. Then, the ESR spectra of the powder samples prepared from the bones of the drumsticks have been investigated. Unirradiated chicken bones have been observed to show a weak ESR signal of single line character. CO-2 ionic radicals of axial symmetry with g=1.9973 and g=2.0025 were observed to be produced in irradiated samples which would give rise to a three peaks ESR spectrum. In addition, the signal intensities of the samples were found to depend linearly on the irradiation dose in the dose range of 0-10 kGy. The powder samples prepared from chicken leg bones cleaned from their meats and marrow and irradiated at dose levels of 1, 2, 3, 4, 5, 6, B, 10, 12,14, 16, 1B, 20 and 22 kGy were used to get the dose-response curve. It was found that this curve has biphasic character and that the dose yield was higher in the 12-1B kGy dose range and a decrease appears in this curve over 18 kGy. The radical produced in the bones were found to be the same whether the irradiation was performed after stripping the meat and removing the marrow from the bone or before the stripping. The ESR spectra of both irradiated and non irradiated samples were investigated in the temperature range of 100 K-450 K and changes in the ESR spectra of CO-2 radical have been studied. For non irradiated samples (controls). the signal intensities were found to decrease when the temperature was increased. The same investigation has been carried out for irradiated samples and it was concluded that the signal intensities relative to the peaks of the radical spectrum increase in the temperature range of 100 K-330 K, then they decrease over 330 K. The change in the

  3. Radiation dosimetry by ESR in bone

    International Nuclear Information System (INIS)

    Gallegos, R.; Marticorena, B.

    1983-01-01

    The absorption speed in bovine bone samples irradiated with a 90 Sr β-source of 45 mCi is studied with ESR. The signal changes linearly with the absorbed quantity of radiation to a maximum dose of 1.5 x 10 6 rads. This positive result allows to foresee the use of bone as a radiation dosimeter

  4. Radiation dosimetry by ESR in bone

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, R. (Universidad de San Agustin de Arequipa (Peru)); Marticorena, B. (Instituto Peruano de Energia Nuclear, Lima)

    1983-05-01

    The absorption speed in bovine bone samples irradiated with a /sup 90/Sr ..beta..-source of 45 mCi is studied with ESR. The signal changes linearly with the absorbed quantity of radiation to a maximum dose of 1.5 x 10/sup 6/ rads. This positive result allows to foresee the use of bone as a radiation dosimeter.

  5. ESR study of the radiolysis of cellobiose, cellulose-containing materials, and their mixtures with methyl methacrylate

    International Nuclear Information System (INIS)

    Kozlova, E.Y.; Shostenko, A.G.; Ermolaev, S.V.

    1995-01-01

    The ESR spectra of γ-irradiated cellobiose, paper waste, and cellulose extracted from paper waste and waste pulp sludge were analyzed. The kinetics of formation and decay of cellobiose radicals were investigated, and the radiation-chemical yields of the radicals formed in cellulose-containing materials were calculated. The ESR spectra of cellobiose irradiated in the presence of methyl methacrylate (MMA) were obtained. A probable mechanism of MMA grafting onto cellulose-containing matrices is considered

  6. Time-resolved brightness measurements by streaking

    Science.gov (United States)

    Torrance, Joshua S.; Speirs, Rory W.; McCulloch, Andrew J.; Scholten, Robert E.

    2018-03-01

    Brightness is a key figure of merit for charged particle beams, and time-resolved brightness measurements can elucidate the processes involved in beam creation and manipulation. Here we report on a simple, robust, and widely applicable method for the measurement of beam brightness with temporal resolution by streaking one-dimensional pepperpots, and demonstrate the technique to characterize electron bunches produced from a cold-atom electron source. We demonstrate brightness measurements with 145 ps temporal resolution and a minimum resolvable emittance of 40 nm rad. This technique provides an efficient method of exploring source parameters and will prove useful for examining the efficacy of techniques to counter space-charge expansion, a critical hurdle to achieving single-shot imaging of atomic scale targets.

  7. Watching proteins function with time-resolved x-ray crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Šrajer, Vukica; Schmidt, Marius

    2017-08-22

    Macromolecular crystallography was immensely successful in the last two decades. To a large degree this success resulted from use of powerful third generation synchrotron x-ray sources. An expansive database of more than 100 000 protein structures, of which many were determined at resolution better than 2 Å, is available today. With this achievement, the spotlight in structural biology is shifting from determination of static structures to elucidating dynamic aspects of protein function. A powerful tool for addressing these aspects is time-resolved crystallography, where a genuine biological function is triggered in the crystal with a goal of capturing molecules in action and determining protein kinetics and structures of intermediates (Schmidt et al 2005a Methods Mol. Biol. 305 115–54, Schmidt 2008 Ultrashort Laser Pulses in Biology and Medicine (Berlin: Springer) pp 201–41, Neutze and Moffat 2012 Curr. Opin. Struct. Biol. 22 651–9, Šrajer 2014 The Future of Dynamic Structural Science (Berlin: Springer) pp 237–51). In this approach, short and intense x-ray pulses are used to probe intermediates in real time and at room temperature, in an ongoing reaction that is initiated synchronously and rapidly in the crystal. Time-resolved macromolecular crystallography with 100 ps time resolution at synchrotron x-ray sources is in its mature phase today, particularly for studies of reversible, light-initiated reactions. The advent of the new free electron lasers for hard x-rays (XFELs; 5–20 keV), which provide exceptionally intense, femtosecond x-ray pulses, marks a new frontier for time-resolved crystallography. The exploration of ultra-fast events becomes possible in high-resolution structural detail, on sub-picosecond time scales (Tenboer et al 2014 Science 346 1242–6, Barends et al 2015 Science 350 445–50, Pande et al 2016 Science 352 725–9). We review here state-of-the-art time-resolved crystallographic experiments both at synchrotrons and XFELs. We

  8. Watching proteins function with time-resolved x-ray crystallography

    International Nuclear Information System (INIS)

    Šrajer, Vukica; Schmidt, Marius

    2017-01-01

    Macromolecular crystallography was immensely successful in the last two decades. To a large degree this success resulted from use of powerful third generation synchrotron x-ray sources. An expansive database of more than 100 000 protein structures, of which many were determined at resolution better than 2 Å, is available today. With this achievement, the spotlight in structural biology is shifting from determination of static structures to elucidating dynamic aspects of protein function. A powerful tool for addressing these aspects is time-resolved crystallography, where a genuine biological function is triggered in the crystal with a goal of capturing molecules in action and determining protein kinetics and structures of intermediates (Schmidt et al 2005a Methods Mol. Biol . 305 115–54, Schmidt 2008 Ultrashort Laser Pulses in Biology and Medicine (Berlin: Springer) pp 201–41, Neutze and Moffat 2012 Curr. Opin. Struct. Biol . 22 651–9, Šrajer 2014 The Future of Dynamic Structural Science (Berlin: Springer) pp 237–51). In this approach, short and intense x-ray pulses are used to probe intermediates in real time and at room temperature, in an ongoing reaction that is initiated synchronously and rapidly in the crystal. Time-resolved macromolecular crystallography with 100 ps time resolution at synchrotron x-ray sources is in its mature phase today, particularly for studies of reversible, light-initiated reactions. The advent of the new free electron lasers for hard x-rays (XFELs; 5–20 keV), which provide exceptionally intense, femtosecond x-ray pulses, marks a new frontier for time-resolved crystallography. The exploration of ultra-fast events becomes possible in high-resolution structural detail, on sub-picosecond time scales (Tenboer et al 2014 Science 346 1242–6, Barends et al 2015 Science 350 445–50, Pande et al 2016 Science 352 725–9). We review here state-of-the-art time-resolved crystallographic experiments both at synchrotrons and XFELs

  9. Free radicals in cellulose containing food detected by ESR

    International Nuclear Information System (INIS)

    Abe, Aika; Yogo, Satsuki; Ichii, Akane; Ukai, Mitsuko

    2003-01-01

    Using electron spin resonance (ESR) spectroscopy, we revealed three radical species in cellulose containing foods, pepper and green tea. These are commercially available in Japan. The representative ESR spectrum is composed of a sextet centered at g=2.0, a singlet at the same g-value, and a singlet at g=4.0. The first one is attributable to a signal with hyperfine (hf) interactions of Mn 2+ ion (hf constant: 7.4 mT). The second one is due to an organic free radical, the third one may be originated from Fe 3+ ion. The progressive saturation behavior (PSB) of the ESR at various microwave power levels were indicated different relaxation behaviors of in those radicals. Namely, the peak intensity of the organic free radical component decreases in a monotonic fashion, whereas the Mn 2+ and Fe 3+ ESR signals substantially keep constant. This reflects the evidence of three independent radical species. The ESR spectrum of the cellulose containing foods shows the same spectral feature irrespective of the tea or pepper. Upon gamma irradiation, a new pair of signals appeared. The PSB of the pair peaks after the irradiation showed a quite different as compared with the free radical centered at g=2. (author)

  10. Submillimeter wave ESR of copper-oxides

    International Nuclear Information System (INIS)

    Ohta, Hitoshi; Motokawa, Mitsuhiro

    1993-01-01

    Since the discovery of high T c superconductors the magnetism of various copper-oxides has attracted much interest. Especially the magnetism of strong spin correlation systems in various CuO 4 networks is of great interest because it is well known that the superconductivity is occurring in the CuO 2 plane of the high T c superconductors. Here the authors will show some of their work done on copper-oxides by submillimeter wave ESR. The submillimeter wave ESR can provide the frequency region of 90 ∼ 3,100 GHz and the pulse magnetic field up to 30T

  11. Application of ESR to identification of irradiated foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Raffi, J. [Aix-Marseille-3 Univ., 13 - Marseille (France); Agnel, J.P. [CEA Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Physiologie Vegetale et Ecosystemes; Belliardo, J.J. [BCR, Bruxelles (Belgium)

    1994-11-01

    The conditions required to use Electron Spin Resonance (ESR) in identification of irradiated foods is first described. Then we present the results of an intercomparison sponsored by the Community Bureau of Reference involving 22 european laboratories on meat and fish bones and fruits. Then the ESR protocols given to the BCR are described. (authors). 14 refs., 8 figs., 5 annexes.

  12. Time-resolved fluorescence quenching studies of sodium lauryl ether sulfate micelles

    OpenAIRE

    Friedrich, Leidi C.; Silva, Volnir O.; Moreira Jr, Paulo F.; Tcacenco, Celize M.; Quina, Frank H.

    2013-01-01

    Aggregation numbers (N Ag) of micelles of the commercial anionic detergent sodium lauryl ether sulfate (SLES), with an average of two ethylene oxide subunits, were determined at 30 and 40º C by the time-resolved fluorescence quenching method with pyrene as the fluorescent probe and the N-hexadecylpyridinium ion as the quencher. The added-salt dependent growth of SLES micelles (γ = 0.11-0.15, where γ is the slope of a plot of log aggregation number vs. log [Yaq] and [Yaq] is the sodium counter...

  13. In vivo dose evaluation during gynaecological radiotherapy using L-alanine/ESR dosimetry

    International Nuclear Information System (INIS)

    Burg Rech, Amanda; Baffa, Oswaldo; Barbi, Gustavo Lazzaro; Almeida Ventura, Luiz Henrique; Silva Guimaraes, Flavio; Oliveira, Harley Francisco

    2014-01-01

    The dose delivered by in vivo 3-D external beam radiation therapy (EBRT) was verified with L-alanine/electron spin resonance (ESR) dosimetry for patients diagnosed with gynaecological cancer. Measurements were performed with an X-band ESR spectrometer. Dosemeters were positioned inside the vaginal cavity with the assistance of an apparatus specially designed for this study. Previous phantom studies were performed using the same conditions as in the in vivo treatment. Four patients participated in this study during 20-irradiation sessions, giving 220 dosemeters to be analysed. The doses were determined with the treatment planning system, providing dose confirmation. The phantom study resulted in a deviation between -2.5 and 2.1 %, and for the in vivo study a deviation between -9.2 and 14.2 % was observed. In all cases, the use of alanine with ESR was effective for dose assessment, yielding results consistent with the values set forth in the International Commission on Radiation Units and Measurements (ICRU) reports. (authors)

  14. Spin and time-resolved magnetic resonance in radiation chemistry. Recent developments and perspectives

    International Nuclear Information System (INIS)

    Shkrob, I.A.; Trifunac, A.D.

    1997-01-01

    Time-resolved pulsed EPR and ODMR in studies on early events in radiation chemistry are examined. It is concluded that these techniques yield valuable and diverse information about chemical reactions in spurs, despite the fact that the spur reactions occur on a time scale that is much shorter than the time resolution of these methods. Several recent examples include EPR of H/D atoms in vitreous silica and cryogenic liquids and ODMR of doped alkane solids and amorphous semiconductors. It is argued that a wider use of time-resolved magnetic resonance methods would benefit the studies on radiation chemistry of disordered solids, simple liquids, and polymers. (author)

  15. ESR spectroscopy - an analytical tool for the glass industry

    International Nuclear Information System (INIS)

    Elvers, A.; Weissmann, R.

    2001-01-01

    In the past, wet chemical methods have been developed for the quantitative analysis of polyvalent elements in glasses. The major disadvantage of these chemical methods is that all structural information is lost during analysis. In addition, the analysis of species by wet chemical methods is unreliable due to possible redox reactions during the decomposition process. Therefore, the emphasis is on the physical methods which can directly detect species in bulk glasses. Especially optical and ESR spectroscopy are suitable methods due to their wide range of applications and sensitivity. Concerning quantitative measurements, no comparison between ESR results and chemical analysis of species has been published so far. This work discusses the possible application of ESR spectroscopy in the glass industry by focussing on routine interpretation, the correlation to chemical procedures and quantitative analysis. Results are presented and discussed for iron and chromium in packaging glasses. For example an excellent correlation was found between the Fe 3+ ESR signal and the chemically determined Fe 3+ concentration in glass. (orig.)

  16. ESR dosimetric properties of modern coral reef

    Energy Technology Data Exchange (ETDEWEB)

    Sharaf, M.A. E-mail: mokhtar_sharaf@yahoo.com; Hassan, Gamal M

    2004-06-01

    Modern coral reef samples from Egypt were irradiated with {sup 60}Co{gamma}-rays to study radicals for dosimetric materials with electron spin resonance (ESR). The ESR spectrum for the radical species in unirradiated coral is characterized by four signals with spectroscopic splitting factors of g=2.0056, 2.0030, 2.0006 and 1.997. The signal at g=2.0006{+-}0.0005 is ascribed to free rotation CO{sub 2}{sup -} radicals and used as a dosimetric one. The response to {gamma}-ray doses ranging from 5 to 10{sup 3} Gy and the thermal stability has been studied. The number of free radicals per 100 eV (G-value) was found to be 0.45 {+-} 0.1 and 0.9 {+-} 0.18 for coral and alanine, respectively. The lifetime of radicals and the activation energy were estimated from Arrhenius plots to be approximately 8 x 10{sup 5} {+-} 1.6 x 10{sup 5} years, and 1.12 eV, respectively.

  17. Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy

    International Nuclear Information System (INIS)

    Gallo, Salvatore; Veronese, Ivan; Iacoviello, Giuseppina; Panzeca, Salvatore; Bartolotta, Antonio; Longo, Anna; Dondi, Daniele; Gueli, Anna Maria; Loi, Gianfranco; Mones, Eleonora; Marrale, Maurizio

    2017-01-01

    This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076 registered ) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076 registered is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy. (orig.)

  18. Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gallo, Salvatore; Veronese, Ivan [Universita degli Studi di Milano, Department of Physics, Milan (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano (Italy); Iacoviello, Giuseppina [Hospital ARNAS-Civico, Medical Physics Department, Palermo (Italy); Panzeca, Salvatore [Universita degli Studi di Palermo, Department of Physics and Chemistry, Palermo (Italy); Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania (Italy); Bartolotta, Antonio; Longo, Anna [Universita degli Studi di Palermo, Department of Physics and Chemistry, Palermo (Italy); Dondi, Daniele [Universita degli Studi di Pavia, Department of Chemistry, Pavia (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pavia (Italy); Gueli, Anna Maria [Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania (Italy); Universita degli Studi di Catania, Department of Physics and Astronomy, PH3DRA Laboratories, Catania (Italy); Loi, Gianfranco; Mones, Eleonora [Azienda Ospedaliero Universitaria Maggiore della Carita, Medical Physics Department, Novara (Italy); Marrale, Maurizio [Universita degli Studi di Palermo, Department of Physics and Chemistry, Palermo (Italy); Istituto Nazionale di Fisica Nucleare-Sezione di Catania, Catania (Italy); Universita degli Studi di Palermo, Advanced Technologies Network Center (ATeN Center), Palermo (Italy)

    2017-11-15

    This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076 {sup registered}) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076 {sup registered} is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy. (orig.)

  19. The high-frequency ESR spectra of the syntetic diamond and nanodiamonds type Ib at low temperature

    International Nuclear Information System (INIS)

    Khatsko, E.; Kobets, M.; Dergachev, K.; Kulbickas, A.; Rasteniene, L.; Vaisnoras, R.

    2013-01-01

    The ESR absorption spectra of nonirradiated and irradiated (by electrons with an energy of 2 MeV) bulk diamond and nanodiamond powder of type Ib have been studied at a wide range of frequencies (70-20 GHz) and temperature (4.2-0 K) by ESR method. It is shown, that in the ESR spectrum of bulk diamond absorption lines of ion nickel catalyst Ni +a nd a paramagnetic single center of the nitrogen N 0 is observed. Absorption lines of the paramagnetic centers with dangling bonds on the nanodiamond surface (surface defects) in the ESR spectra are obtained.

  20. ESR investigation of radicals formed in γ-irradiated vinylidene fluoride based copolymer: P(VDF-co-HFP)

    International Nuclear Information System (INIS)

    Dumas, Ludovic; Albela, Belén; Bonneviot, Laurent; Portinha, Daniel; Fleury, Etienne

    2013-01-01

    Samples of copolymer based on vinylidene fluoride and hexafluoropropene P(VDF-co-HFP) were exposed to γ-radiation performed under an inert atmosphere and the total amount of radicals was quantified by electron spin resonance spectroscopy (ESR). An in-depth study of recorded ESR spectra allowed the identification of several types of radical species formed during radiolysis. Starting from an ESR simulation model established for irradiated PVDF, seven radical species have been identified in the case of P(VDF-co-HFP): five of them are related to the VDF units while the two others are derived from the HFP unit. The model used to simulate the complex superimposed ESR signals is presented. The proportions of each species are discussed and correlated to the amount of HFP units contained in the copolymer, and to the stability of each species depending on their local environment. Furthermore, the evolution of radical density with radiation dose and the decay resulting from annealing at a given temperature are presented. Corresponding spectral evolution shows the progressive predominance of most stable species. - Highlights: ► ESR signal of γ-irradiated P(vinylidene fluoride-co-hexafluoropropene) containing 6 wt% of hexafluoropropene is modeled. ► The formation of seven major radical species is proposed for the first time. ► Despite a low comonomer content, 43% of radicals are localized on hexafluoropropene. ► Effect of dose and annealing highlight radical stability. ► Radical stability is found to depend on both chemical environment and chain location

  1. Investigations of radical primary processes by ESR pulse radiolysis and ESR laser photolysis experiments

    International Nuclear Information System (INIS)

    Beckert, D.; Mehler, K.; Naumann, W.

    1984-08-01

    The Chemically Induced Magnetic Polarization of Electrons (CIDEP) describes the anomalies of ESR intensities of free radicals which react chemically. In this paper the fundamentals and some experimental results of the CIDEP effect are summarized. (author)

  2. Femtosecond time-resolved two-photon photoemission study of organic semiconductor copper phthalocyanine film

    International Nuclear Information System (INIS)

    Tanaka, A.; Tohoku University; University of Rochester, NY; Yan, L.; Watkins, N.J.; Gao, Y.

    2004-01-01

    Full text: Organic semiconductors are recently attracting much interest from the viewpoints of both device and fundamental physics. These organic semiconductors are considered to be important constituents of the future devices, such as organic light-emitting diode, organic field effect transistor, and organic solid-state injection laser. In order to elucidate their detailed physical properties and to develop the future devices, it is indispensable to understand their excited-state dynamics as well as their electronic structures. The femtosecond time-resolved two-photon photoemission (TR-2PPE) spectroscopy is attracting much interest because of its capability to observe the energy-resolved excited electron dynamics. In this work, we have carried out a TR-2PPE study of the organic semiconductor copper phthalocyanine (CuPc) film. Furthermore, we have investigated the detailed electronic structure of CuPc film using the photoemission (PES) and inverse photoemission (IPES) spectroscopies. From the simultaneous PES and IPES measurements for CuPc film with a thickness of 100 nm, the lowest unoccupied molecular orbital (LUMO), highest occupied molecular orbital, and ionization potential of CuPc film have been directly determined. The observed two-photon photoemission (2PPE) spectrum of the present CuPc film, measured with photon energy of about hv=3.3 eV, exhibits a broad feature. From the energy diagram of CuPc film determined by the PES and IPES measurements, the intermediate state observed in the present 2PPE spectrum of CuPc film corresponds to the energy region between about 0.4 and 1.7 eV above the LUMO energy. From the time-resolved pump-probe measurements, it is found that the relaxation lifetimes of excited states in the present CuPc films are very short (all below 50 fs) and monotonously become faster with increasing excitation energy. We attribute this extremely fast relaxation process of photoexcitation to a rapid internal conversion process. From these results

  3. Computer enhancement of ESR spectra of magnetite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Dobosz, B.; Krzyminiewski, R. [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznan (Poland); Koralewski, M. [Optics Laboratory, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznan (Poland); Hałupka-Bryl, M. [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznan (Poland); The PhD Program in Nanoscience and Nanotechnology, The Nanobiomedical Centre, Umultowska 85, 61-614 Poznan (Poland)

    2016-06-01

    We present ESR measurements of non-interacting magnetic nanoparticle systems. Temperature and orientational dependence of ESR spectra were measured for Fe{sub 3}O{sub 4} nanoparticle coated by dextran or oleic acid, frozen in different magnetic field. Several parameters describing magnetic properties such as g-factor, line width, the anisotropy constant were calculated and discussed. The ESR spectra of investigated nanoparticles were also subjected to Computer Resolution Enhancement Method (CREM). This procedure allows to separate a narrow line on the background of the broad line, which presence in this type of materials was recognized in the recent literature and have been further discussed in the paper. CREM is a valuable tool for monitoring of changes on the surface of magnetic core of nanoparticles. - Highlights: • CREM – a new tool for monitoring of changes on the surface of magnetic core of nanoparticles. • CREM allows to separate a narrow line on the background of the broad line. • Temperature and orientational dependence of ESR spectra of Fe{sub 3}O{sub 4} nanoparticles were measured. • Parameters describing magnetic properties were calculated and discussed.

  4. Time Resolved Deposition Measurements in NSTX

    International Nuclear Information System (INIS)

    Skinner, C.H.; Kugel, H.; Roquemore, A.L.; Hogan, J.; Wampler, W.R.

    2004-01-01

    Time-resolved measurements of deposition in current tokamaks are crucial to gain a predictive understanding of deposition with a view to mitigating tritium retention and deposition on diagnostic mirrors expected in next-step devices. Two quartz crystal microbalances have been installed on NSTX at a location 0.77m outside the last closed flux surface. This configuration mimics a typical diagnostic window or mirror. The deposits were analyzed ex-situ and found to be dominantly carbon, oxygen, and deuterium. A rear facing quartz crystal recorded deposition of lower sticking probability molecules at 10% of the rate of the front facing one. Time resolved measurements over a 4-week period with 497 discharges, recorded 29.2 (micro)g/cm 2 of deposition, however surprisingly, 15.9 (micro)g/cm 2 of material loss occurred at 7 discharges. The net deposited mass of 13.3 (micro)g/cm 2 matched the mass of 13.5 (micro)g/cm 2 measured independently by ion beam analysis. Monte Carlo modeling suggests that transient processes are likely to dominate the deposition

  5. Comparison of ESR1 Mutations in Tumor Tissue and Matched Plasma Samples from Metastatic Breast Cancer Patients

    Directory of Open Access Journals (Sweden)

    Takashi Takeshita

    2017-10-01

    Full Text Available BACKGROUND: ESR1 mutation in circulating cell-free DNA (cfDNA is emerging as a noninvasive biomarker of acquired resistance to endocrine therapy, but there is a paucity of data comparing the status of ESR1 gene in cfDNA with that in its corresponding tumor tissue. The objective of this study is to validate the degree of concordance of ESR1 mutations between plasma and tumor tissue. METHODS: ESR1 ligand-binding domain mutations Y537S, Y537N, Y537C, and D538G were analyzed using droplet digital PCR in 35 patients with metastatic breast cancer (MBC (35 tumor tissue samples and 67 plasma samples. RESULTS: Of the 35 paired samples, 26 (74.3% were concordant: one patient had detectable ESR1 mutations both plasma (ESR1 Y537S/Y537N and tumor tissue (ESR1 Y537S/Y537C, and 25 had WT ESR1 alleles in both. Nine (25.7% had discordance between the plasma and tissue results: five had mutations detected only in their tumor tissue (two Y537S, one Y537C, one D538G, and one Y537S/Y537N/D538G, and four had mutations detected only in their plasma (one Y537S, one Y537N, and two Y537S/Y537N/D538G. Furthermore, longitudinal plasma samples from 19 patients were used to assess changes in the presence of ESR1 mutations during treatment. Eleven patients had cfDNA ESR1 mutations over the course of treatment. A total of eight of 11 patients with MBC with cfDNA ESR1 mutations (72.7% had the polyclonal mutations. CONCLUSION: We have shown the independent distribution of ESR1 mutations between plasma and tumor tissue in 35 patients with MBC.

  6. Alanine-ESR dosimeter: application for dosimetry in industrial electron beam accelerator

    International Nuclear Information System (INIS)

    Murali, S.; Venkataramani, R.; Pushparaja; Sarma, K.S.S.; Natarajan, V.; Sastry, M.D.

    2000-01-01

    The feasibility of DL-α-alanine, as ESR dosimeter in powder form, was examined under the conditions of pulse electron accelerator used as an industrial irradiator. The investigations were carried out to examine the following aspects: (i) Alanine-ESR dose response in irradiator characteristics viz. various beam energies, beam currents, product conveying speeds, (ii) linearity of dose response of irradiated alanine signal for suitable range, (iii) dose uniformity of the irradiated samples and (iv) depth dose measurements using alanine powder dosimeters sandwiched between polyethylene layers. Experiments were carried out by varying some of the irradiator parameters at mobile mode of the conveyor (product under movement) and also at stationary mode for different EB energies and pulse rates. For estimation of EB dose, signal intensities of gamma irradiated DL--alanine powder calibrated with Fricke dosimetry have been used. Feasibility of application of alanine ESR dosimeter for low dose measurement down to 350 Gy has been experimentally established. The present studies show that under variable operating conditions of irradiator, alanine ESR dosimetry is suitable for dosimetric applications from low dose (350 Gy) to high dose (53 kgy). (author)

  7. Time-resolved studies of ultrarapid solidification of highly undercooled molten silicon formed by pulsed laser irradiation

    International Nuclear Information System (INIS)

    Lowndes, D.H.; Jellison, G.E. Jr.; Wood, R.F.; Carpenter, R.

    1984-01-01

    This paper reports new results of nanosecond-resolution time-resolved optical reflectivity measurements, during pulsed excimer (KrF, 248 nm) laser irradiation of Si-implanted amorphous (a) silicon layers, which, together with model calculations and post-irradiation TEM measurements, have allowed us to study both the transformation of a-Si to a highly undercooled liquid (l) phase and the subsequent ultrarapid solidification process

  8. Charge recombination processes in minerals studied using optically stimulated luminescence and time-resolved exo-electrons

    DEFF Research Database (Denmark)

    Tsukamoto, Sumiko; Murray, Andrew; Ankjærgaard, Christina

    2010-01-01

    electron concentration in the conduction band. In this study, TR-OSE and time-resolved optically stimulated luminescence (TR-OSL) were measured for the first time using quartz, K-feldspar and NaCl by stimulating the samples using pulsed blue LEDs at different temperatures between 50 and 250 °C after beta...... irradiation and preheating to 280 °C. The majority of TR-OSE signals from all the samples decayed much faster than TR-OSL signals irrespective of the stimulation temperatures. This suggests that the lifetime of OSL in these dosimeters arises mainly from the relaxation of an excited state of the recombination...

  9. Time-resolved studies of direct effects of radiation on DNA

    International Nuclear Information System (INIS)

    Fielden, E.M.; O'Neill, P.; Al-Kazwini, A.

    1987-01-01

    The biological changes induced by ionising radiation are a consequence of radiation-induced chemical events taking place at times <1s. These events are strongly influenced by the presence of chemical modifiers. Since DNA is a principle target for radiation-induced cell killing, DNA-free radicals are generated by direct ionisation of DNA moieties (direct effect) and by reaction with hydroxyl radicals formed by radiolysis of the water which is in the vicinity of the DNA (indirect effect). In order to study the 'direct' effects of radiation on DNA the following model approaches are discussed:- 1) Use of the technique of pulse radiolysis to investigate in aqueous solution the interactions of deoxynucleosides with SO/sub 4//sup .-/ whereby one-electron oxidised species of the bases are generated; and 2) time resolved, radiation-induced changes to solid DNA and related macromolecules (e.g. radiation-induced luminescence) in order to obtain an understanding of charge/energy migration as a result of ionisation of DNA. The influence of chemical modifiers and of environment is discussed in terms of the properties of the radiation-induced species produced. Since the properties of base radicals produced by SO/sub 4//sup .-/ are similar to those of the base OH-adducts oxidising properties, potential similarities between the 'direct' and 'indirect' effects of radiation are presented

  10. ESR imaging for estimation oxidative stress in the brain of rats

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Hidekatsu; Itoh, Osam; Aoyama, Masaaki; Obara, Heitaro; Ohya, Hiroaki; Kamada, Hitoshi [Inst. for Life Support Technology, Matsuei, Yamagata (Japan)

    2002-04-01

    ESR imaging for estimating intracerebral oxidative stress of rats was performed. An acyl-protected hydroxylamine, 1-acetoxy-3-carbamoyl-2,2,5,5-tetramethylpyrrolidine (ACP), is a very stable non-radical compound outside cells, however, within cells, it is easily deprotected with esterase to yield 1-hydroxy-3-carbamoyl-2,2,5,5-tetramethylpyrrolidine, which is oxidized by oxidative stress to yield an ESR-detectable stable nitroxide radical, 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl. Thus signal intensity in the ESR image reflects the strength of intracellular oxidative stress. From in vivo ESR image data of the brain of rats that received ACP, the average values of ESR signal intensity from the hippocampus, striatum, and cerebral cortex were computed. This imaging technique was applied to an epileptic seizure model. As a result, it was found that following a kainic acid-induced seizure, the oxidative stress in the hippocampus and striatum is enhanced, but not so in the cerebral cortex. (author)

  11. Rapid screening for anthocyanins in cane sugars using ESR spectroscopy.

    Science.gov (United States)

    Thamaphat, Kheamrutai; Goodman, Bernard A; Limsuwan, Pichet; Smith, Siwaporn Meejoo

    2015-03-15

    Anthocyanin, which is soluble in water and released into sugar steam during extraction, was investigated in this study. The anthocyanin content in refined sugar, plantation white sugar, soft brown sugar and raw sugar was determined using electron spin resonance (ESR) spectroscopy, which was operated at room temperature, and compared with spectra from standard anthocyanin. The ESR spectra of red and violet anthocyanins was predominantly g ≈ 2.0055, which corresponded to an unpaired electron located in the pyrylium ring. Signals for Fe(III) and Mn(II), which naturally occur in plants, were found in raw sugar, soft brown sugar and standard anthocyanin but were absent from refined sugar and plantation white sugar due to the refining process. In addition, the ESR results were correlated with the apparent colour of the sugar, which was determined using the method of the International Commission for Uniform Methods of Sugar Analysis and inductively coupled plasma optical emission spectroscopy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Time-resolved circular dichroism: Application to the study of conformal changes in biomolecules

    Science.gov (United States)

    Hache, F.

    2010-06-01

    Circular dichroism (CD) is known to be a very sensitive probe of the conformation of molecules and biomolecules. It is therefore tempting to implement CD in a pump-probe experiment in order to measure ultrarapid conformational changes which occur in photochemical processes. We present two technical developments of such time-resolved CD experiments. The first one relies on the modulation of the probe polarization from left to right circular whereas the second one measures the pump-induced ellipticity of the probe with a Babinet-Soleil compensator. Some applications are described and extension of these techniques towards the study of elementary protein folding processes is discussed.

  13. Time-resolved circular dichroism: Application to the study of conformal changes in biomolecules

    Directory of Open Access Journals (Sweden)

    Hache F.

    2010-06-01

    Full Text Available Circular dichroism (CD is known to be a very sensitive probe of the conformation of molecules and biomolecules. It is therefore tempting to implement CD in a pump-probe experiment in order to measure ultrarapid conformational changes which occur in photochemical processes. We present two technical developments of such time-resolved CD experiments. The first one relies on the modulation of the probe polarization from left to right circular whereas the second one measures the pump-induced ellipticity of the probe with a Babinet-Soleil compensator. Some applications are described and extension of these techniques towards the study of elementary protein folding processes is discussed.

  14. Timepix3 as X-ray detector for time resolved synchrotron experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yousef, Hazem, E-mail: hazem.yousef@diamond.ac.uk; Crevatin, Giulio; Gimenez, Eva N.; Horswell, Ian; Omar, David; Tartoni, Nicola

    2017-02-11

    The Timepix3 ASIC can be used very effectively for time resolved experiments at synchrotron facilities. We have carried out characterizations with the synchrotron beam in order to determine the time resolution and other characteristics such as the energy resolution, charge sharing and signals overlapping. The best time resolution achieved is 19 ns FWHM for 12 keV photons and 350 V bias voltage. The time resolution shows dependency on the photon energy as well as on the chip and acquisition parameters. - Highlights: • An estimate time resolution of the Timepix3 is produced based on the arrival time. • At high resolution, the time structure of the DLS synchrotron beam is resolved. • The arrival time information improves combining the charge split events. • The results enable performing a wide range of time resolved experiments.

  15. Timepix3 as X-ray detector for time resolved synchrotron experiments

    International Nuclear Information System (INIS)

    Yousef, Hazem; Crevatin, Giulio; Gimenez, Eva N.; Horswell, Ian; Omar, David; Tartoni, Nicola

    2017-01-01

    The Timepix3 ASIC can be used very effectively for time resolved experiments at synchrotron facilities. We have carried out characterizations with the synchrotron beam in order to determine the time resolution and other characteristics such as the energy resolution, charge sharing and signals overlapping. The best time resolution achieved is 19 ns FWHM for 12 keV photons and 350 V bias voltage. The time resolution shows dependency on the photon energy as well as on the chip and acquisition parameters. - Highlights: • An estimate time resolution of the Timepix3 is produced based on the arrival time. • At high resolution, the time structure of the DLS synchrotron beam is resolved. • The arrival time information improves combining the charge split events. • The results enable performing a wide range of time resolved experiments.

  16. The importance of pre-annealing treatment for ESR dating of mollusc shells: A key study for İsmil in Konya closed Basin/Turkey

    Science.gov (United States)

    Ekici, Gamze; Sayin, Ulku; Aydin, Hulya; Isik, Mesut; Kapan, Sevinc; Demir, Ahmet; Engin, Birol; Delikan, Arif; Orhan, Hukmu; Biyik, Recep; Ozmen, Ayhan

    2018-02-01

    In this study, Electron Spin Resonance (ESR) spectroscopy is used to determine the geological ages of fossil mollusc shells systematically collected from two different geological splitting at İsmil Location (37.72769° N, 33.17781° E) in eastern part of Konya. According to the assessment of obtained ESR ages, the importance of pre-annealing treatment emphasize in the case of g=2.0007 dating signal is overlapped with the other signals arisen from short lived radicals that cause the wrong age calculation. To overcome this problem, the samples are pre-annealed at 180°C for 16 minutes and, in this case ESR ages are re-calculated for g=1.9973 dating signal. Dose response curves are obtained using 1.9973 signals after pre-annealing treatments for each samples. ESR ages of samples are obtained in the range of 138 ± 38 ka and 132 ± 30 ka (Upper Pleistocene) according to the Early Uranium Uptake model and the results are in good agreement with the estimated ages from stratigraphic and paleontological correlation by geologists. Thus, it is suggested that especially in the case of 2.0007 dating signal cannot been used due to superimposition case, the signal with 1.9973 g value can be used for dating after pre-annealing treatment. The results reports the first ESR ages on shells collected from İsmil Location and highlight the importance of pre-annealing treatment. This study is supported by TUBITAK 114Y237 research project.

  17. ESR Spectra of Some Silicate Minerals: A Search For New Dosimetric Materials

    International Nuclear Information System (INIS)

    Abdel-Monem, A.A.; Abdel-Razek, Y.A.; Rasheed, G. M.; Hassan, G.M.; Eissa, H.M.; Morsy, M.

    2008-01-01

    Two silicate minerals talc (Mg 3 Si 4 O 1 0 (OH) 2 ) and zircon (ZrSiO 4 ) having different crystal lattice structures were subjected to ESR dosimetric studies. Zircon shows anisotropic ESR signals at g xx =2.0168, g yy =2.0076 and g zz =2.0033, which have been identified as a hole center associated with Y 3+ substituted at Zr 4+ sites. Other characteristic signals have been observed and identified. The ESR signal at g=2.0033 showed positive response to γ-irradiation at 110 Gy and is suitable to be used for dosimetry and dating of natural zircons. Talc a magnesium sheeted silicate exhibits ESR derivative spectrum characterized the presence of Fe 3+ at g=4.28 and the HF-sixtet Mn 2+ signals due to possible substitution of Fe 3+ and Mn 2+ in the Mg 2+ octahedral sites, respectively. The enhancement of the Mn 2+ sixtet by γ-irradiation increases the area occupied by the signals which makes it difficult to use for dosimetric applications

  18. Development of an ESR/MR dual-imaging system as a tool to detect bioradicals

    International Nuclear Information System (INIS)

    Fujii, Hirotada; Aoki, Masaaki; Haishi, Tomoyuki; Itoh, Kouichi; Sakata, Motomichi

    2006-01-01

    A system combining electron spin resonance imaging (ESRI) with another imaging modality capable of enabling visualization of the distribution of bioradicals on an anatomical map of the specimens would be a superior biomedical imaging system. We describe the development of an electron spin resonance ESR/MR dual-imaging system with one permanent magnet and the biomedical applications of this system. The magnetic circuit developed for the ESR/MR dual-imaging system consisted of the permanent magnet made of Fe-Nd-B, pole pieces, and poke. The permanent magnet was installed on the MR side only, and the ESR side was made of pole pieces only. The magnetic field was adjusted to 0.5T at MR and to 0.042T at ESR. The overall dimensions of the magnet developed for the ESR/MR imaging system were 460 (W) x 440 (D) x 460 (H) mm, and it weighed 220 kg. The distance of each center for the magnet for ESR and MR imaging could be set as close as 200 mm. The entire ESR/MR imaging system can be installed in a common laboratory without magnetic shielding. MR images of plants (myoga) and small animals (mice and rats) were successfully acquired with or without ESR operation. ESR spectra of nitroxyl spin probes were also measured, even with MRI operation. ESR signals of triarylmethyl derivatives with narrow line-width (0.026 mT) were observed in living mice while MRI was operating. The ESR/MR imaging dual functions work properly with no electric or magnetic interference. The ESR/MR dual images demonstrate that this system enables visualization of the distribution of bioradicals on the anatomical map of the object. (author)

  19. LiSr4(BO3)3:Ce3+ phosphor as a new material for ESR dosimetry

    International Nuclear Information System (INIS)

    Jiang, L.H.; Zhang, Y.L.; Gong, X.M.; Pang, R.; Zhang, S.; Li, C.Y.; Su, Q.

    2014-01-01

    LiSr 4 (BO 3 ) 3 :0.01Ce 3+ phosphor was investigated to assess its potential as a material for measurements of radiotherapeutic doses with electron spin resonance (ESR). The ESR spectrum of the phosphor irradiated with 60 Co features five ESR signals. An isochronal annealing experiment has shown that the strongest of these signals is associated with the same trap center as the 473 K peak on the TL glow curve of this material. The dose–response is linear in the studied range from 0.89 to 90.30 Gy. Fading of the signal was also investigated. - Highlights: • LiSr 4 (BO 3 ) 3 :Ce 3+ phosphor can be used as an ESR dosimeter for radiation therapy. • The ESR signal originates from the same traps as the TL. • Dose–response is linear, and the fading is slow

  20. Time-resolved measurements of luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Collier, Bradley B. [Department of Biomedical Engineering, 408 Mechanical Engineering Office Building, Spence Street, Texas A and M University, College Station, TX 77843 (United States); McShane, Michael J., E-mail: mcshane@tamu.edu [Department of Biomedical Engineering, 408 Mechanical Engineering Office Building, Spence Street, Texas A and M University, College Station, TX 77843 (United States); Materials Science and Engineering Program, 408 Mechanical Engineering Office Building, Spence Street, Texas A and M University, College Station, TX 77843 (United States)

    2013-12-15

    Luminescence sensing and imaging has become more widespread in recent years in a variety of industries including the biomedical and environmental fields. Measurements of luminescence lifetime hold inherent advantages over intensity-based response measurements, and advances in both technology and methods have enabled their use in a broader spectrum of applications including real-time medical diagnostics. This review will focus on recent advances in analytical methods, particularly calculation techniques, including time- and frequency-domain lifetime approaches as well as other time-resolved measurements of luminescence. -- Highlights: • Developments in technology have led to widespread use of luminescence lifetime. • Growing interest for sensing and imaging applications. • Recent advances in approaches to lifetime calculations are reviewed. • Advantages and disadvantages of various methods are weighed. • Other methods for measurement of luminescence lifetime also described.

  1. Time-resolved measurements of luminescence

    International Nuclear Information System (INIS)

    Collier, Bradley B.; McShane, Michael J.

    2013-01-01

    Luminescence sensing and imaging has become more widespread in recent years in a variety of industries including the biomedical and environmental fields. Measurements of luminescence lifetime hold inherent advantages over intensity-based response measurements, and advances in both technology and methods have enabled their use in a broader spectrum of applications including real-time medical diagnostics. This review will focus on recent advances in analytical methods, particularly calculation techniques, including time- and frequency-domain lifetime approaches as well as other time-resolved measurements of luminescence. -- Highlights: • Developments in technology have led to widespread use of luminescence lifetime. • Growing interest for sensing and imaging applications. • Recent advances in approaches to lifetime calculations are reviewed. • Advantages and disadvantages of various methods are weighed. • Other methods for measurement of luminescence lifetime also described

  2. An integrated approach using high time-resolved tools to study the origin of aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Di Gilio, A. [Chemistry Department, University of Bari, via Orabona, 4, 70126 Bari (Italy); ARPA PUGLIA, Corso Trieste, 27, 70126 Bari (Italy); Gennaro, G. de, E-mail: gianluigi.degennaro@uniba.it [Chemistry Department, University of Bari, via Orabona, 4, 70126 Bari (Italy); ARPA PUGLIA, Corso Trieste, 27, 70126 Bari (Italy); Dambruoso, P. [Chemistry Department, University of Bari, via Orabona, 4, 70126 Bari (Italy); ARPA PUGLIA, Corso Trieste, 27, 70126 Bari (Italy); Ventrella, G. [Chemistry Department, University of Bari, via Orabona, 4, 70126 Bari (Italy)

    2015-10-15

    Long-range transport of natural and/or anthropogenic particles can contribute significantly to PM10 and PM2.5 concentrations and some European cities often fail to comply with PM daily limit values due to the additional impact of particles from remote sources. For this reason, reliable methodologies to identify long-range transport (LRT) events would be useful to better understand air pollution phenomena and support proper decision-making. This study explores the potential of an integrated and high time-resolved monitoring approach for the identification and characterization of local, regional and long-range transport events of high PM. In particular, the goal of this work was also the identification of time-limited event. For this purpose, a high time-resolved monitoring campaign was carried out at an urban background site in Bari (southern Italy) for about 20 days (1st–20th October 2011). The integration of collected data as the hourly measurements of inorganic ions in PM{sub 2.5} and their gas precursors and of the natural radioactivity, in addition to the analyses of aerosol maps and hourly back trajectories (BT), provided useful information for the identification and chemical characterization of local sources and trans-boundary intrusions. Non-sea salt (nss) sulfate levels were found to increase when air masses came from northeastern Europe and higher dispersive conditions of the atmosphere were detected. Instead, higher nitrate and lower nss-sulfate concentrations were registered in correspondence with air mass stagnation and attributed to local traffic source. In some cases, combinations of local and trans-boundary sources were observed. Finally, statistical investigations such as the principal component analysis (PCA) applied on hourly ion concentrations and the cluster analyses, the Potential Source Contribution Function (PSCF) and the Concentration Weighted Trajectory (CWT) models computed on hourly back-trajectories enabled to complete a cognitive

  3. An integrated approach using high time-resolved tools to study the origin of aerosols

    International Nuclear Information System (INIS)

    Di Gilio, A.; Gennaro, G. de; Dambruoso, P.; Ventrella, G.

    2015-01-01

    Long-range transport of natural and/or anthropogenic particles can contribute significantly to PM10 and PM2.5 concentrations and some European cities often fail to comply with PM daily limit values due to the additional impact of particles from remote sources. For this reason, reliable methodologies to identify long-range transport (LRT) events would be useful to better understand air pollution phenomena and support proper decision-making. This study explores the potential of an integrated and high time-resolved monitoring approach for the identification and characterization of local, regional and long-range transport events of high PM. In particular, the goal of this work was also the identification of time-limited event. For this purpose, a high time-resolved monitoring campaign was carried out at an urban background site in Bari (southern Italy) for about 20 days (1st–20th October 2011). The integration of collected data as the hourly measurements of inorganic ions in PM 2.5 and their gas precursors and of the natural radioactivity, in addition to the analyses of aerosol maps and hourly back trajectories (BT), provided useful information for the identification and chemical characterization of local sources and trans-boundary intrusions. Non-sea salt (nss) sulfate levels were found to increase when air masses came from northeastern Europe and higher dispersive conditions of the atmosphere were detected. Instead, higher nitrate and lower nss-sulfate concentrations were registered in correspondence with air mass stagnation and attributed to local traffic source. In some cases, combinations of local and trans-boundary sources were observed. Finally, statistical investigations such as the principal component analysis (PCA) applied on hourly ion concentrations and the cluster analyses, the Potential Source Contribution Function (PSCF) and the Concentration Weighted Trajectory (CWT) models computed on hourly back-trajectories enabled to complete a cognitive framework

  4. Multi-frame pyramid correlation for time-resolved PIV

    NARCIS (Netherlands)

    Sciacchitano, A.; Scarano, F.; Wieneke, B.

    2012-01-01

    A novel technique is introduced to increase the precision and robustness of time-resolved particle image velocimetry (TR-PIV) measurements. The innovative element of the technique is the linear combination of the correlation signal computed at different separation time intervals. The domain of the

  5. 2 mm range ESR of the transmutation-produced phosphorus impurity in 6HSiC

    International Nuclear Information System (INIS)

    Kalabukhova, E.N.; Lukin, S.N.; Mokhov, E.N.

    1993-01-01

    Phosphorus impurity is introduced into 6HSiC monocrystals via neutron transmutation doping. Parameters of ESR two spectra referred to ESR spectra of separated phosphorus atoms in the lattice cubic and hexagonal position are detected and determined in the specimens at T=4.2 K. variation dynamics of ESR spectra of phosphorus and nitrogen within 4.2-73 K temperature range is studied. Ionization energies of phosphorus atoms are determined to be less, than those of nitrogen atoms, and ionization energy of phosphorus atoms in hexagonal position is higher, than that of phosphorus atoms in cubic position

  6. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter; Determinacion de curvas de isodosis en Radioterapia usando un dosimetro de Alanina/ESR

    Energy Technology Data Exchange (ETDEWEB)

    Chen, F.; Baffa, O.; Graeff, C.F.O. [Departamento de Fisica e Matematica. Universidade de Sao Paulo FFCLRP. 14040-901 Ribeirao Preto-SP (Brazil)

    1998-12-31

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band ({approx} 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  7. Relationship of white blood cell counts, haemoglobin and ESR with IHD

    International Nuclear Information System (INIS)

    Shahzad, F.; Shahzad Tawwab, S.; Abbas, A.

    2009-01-01

    To find any association of white blood cells, haemoglobin and ESR with ischemic heart disease in high risk native population. Methodology: The study included 93 male patients with Ischemic heart disease, between 40 and 60 years of age; 96 age and gender matched subjects. All study participants were non-diabetics. Complete blood cells count, haemoglobin and ESR levels were compared between the patient and control groups. Results: Total leukocyte counts along with neutrophils were significantly higher in the test group compared to the control population (p<0.001) and lymphocytes were significantly lower (p<0.001) in the patient group as compared to the control group. Haemoglobin levels were significantly lower (p<0.001) and ESR was higher (p=0.030) in the patient group as compared to the control group. Conclusion: Although, our findings of the study variables extend previous reports, the prevalence and prognostic importance of theses variables in IHD should be assessed in future experimental studies. These parameters could be important in public health because they are routinely measured by clinicians and may be helpful to predict the risk of future and secondary ischemic events in a high risk population. (author)

  8. Time-resolved X-ray scattering program at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Rodricks, B.

    1994-01-01

    The Time-Resolved Scattering Program's goal is the development of instruments and techniques for time-resolved studies. This entails the development of wide bandpass and focusing optics, high-speed detectors, mechanical choppers, and components for the measurement and creation of changes in samples. Techniques being developed are pump-probe experiments, single-bunch scattering experiments, high-speed white and pink beam Laue scattering, and nanosecond to microsecond synchronization of instruments. This program will be carried out primarily from a white-beam, bend-magnet source, experimental station, 1-BM-B, that immediately follows the first optics enclosure (1-BM-A). This paper will describe the experimental station and instruments under development to carry out the program

  9. Femtosecond time-resolved transient absorption spectroscopy of xanthophylls.

    Science.gov (United States)

    Niedzwiedzki, Dariusz M; Sullivan, James O; Polívka, Tomás; Birge, Robert R; Frank, Harry A

    2006-11-16

    Xanthophylls are a major class of photosynthetic pigments that participate in an adaptation mechanism by which higher plants protect themselves from high light stress. In the present work, an ultrafast time-resolved spectroscopic investigation of all the major xanthophyll pigments from spinach has been performed. The molecules are zeaxanthin, lutein, violaxanthin, and neoxanthin. beta-Carotene was also studied. The experimental data reveal the inherent spectral properties and ultrafast dynamics including the S(1) state lifetimes of each of the pigments. In conjunction with quantum mechanical computations the results address the molecular features of xanthophylls that control the formation and decay of the S* state in solution. The findings provide compelling evidence that S* is an excited state with a conformational geometry twisted relative to the ground state. The data indicate that S* is formed via a branched pathway from higher excited singlet states and that its yield depends critically on the presence of beta-ionylidene rings in the polyene system of pi-electron conjugated double bonds. The data are expected to be beneficial to researchers employing ultrafast time-resolved spectroscopic methods to investigate the mechanisms of both energy transfer and nonphotochemical quenching in higher plant preparations.

  10. Time-resolved pump-probe experiments at the LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Glownia, James; /SLAC /Stanford U., Appl. Phys. Dept.; Cryan, J.; /SLAC /Stanford U., Phys. Dept.; Andreasson, J.; /Uppsala U.; Belkacem, A.; /LBNL, Berkeley; Berrah, N.; /Western Michigan U.; Blaga, C.L.; /Ohio State U.; Bostedt, C.; Bozek, J.; /SLAC; DiMauro, L.F.; /Ohio State U.; Fang, L.; /Western Michigan U.; Frisch, J.; /SLAC; Gessner, O.; /LBNL; Guhr, M.; /SLAC; Hajdu, J.; /Uppsala U.; Hertlein, M.P.; /LBNL; Hoener, M.; /Western Michigan U. /LBNL; Huang, G.; Kornilov, O.; /LBNL; Marangos, J.P.; /Imperial Coll., London; March, A.M.; /Argonne; McFarland, B.K.; /SLAC /Stanford U., Phys. Dept. /SLAC /IRAMIS, Saclay /Stanford U., Phys. Dept. /Georgia Tech /Argonne /Kansas State U. /SLAC /Stanford U., Phys. Dept. /SLAC /Stanford U., Appl. Phys. Dept. /Stanford U., Appl. Phys. Dept. /SLAC /LBNL /Argonne /SLAC /SLAC /Stanford U., Appl. Phys. Dept. /Stanford U., Phys. Dept.

    2011-08-12

    The first time-resolved x-ray/optical pump-probe experiments at the SLAC Linac Coherent Light Source (LCLS) used a combination of feedback methods and post-analysis binning techniques to synchronize an ultrafast optical laser to the linac-based x-ray laser. Transient molecular nitrogen alignment revival features were resolved in time-dependent x-ray-induced fragmentation spectra. These alignment features were used to find the temporal overlap of the pump and probe pulses. The strong-field dissociation of x-ray generated quasi-bound molecular dications was used to establish the residual timing jitter. This analysis shows that the relative arrival time of the Ti:Sapphire laser and the x-ray pulses had a distribution with a standard deviation of approximately 120 fs. The largest contribution to the jitter noise spectrum was the locking of the laser oscillator to the reference RF of the accelerator, which suggests that simple technical improvements could reduce the jitter to better than 50 fs.

  11. Repeat polymorphisms in ESR2 and AR and colorectal cancer risk and prognosis: results from a German population-based case-control study.

    Science.gov (United States)

    Rudolph, Anja; Shi, Hong; Försti, Asta; Hoffmeister, Michael; Sainz, Juan; Jansen, Lina; Hemminki, Kari; Brenner, Hermann; Chang-Claude, Jenny

    2014-11-07

    Evidence has accumulated which suggests that sex steroids influence colorectal cancer development and progression. We therefore assessed the association of repeat polymorphisms in the estrogen receptor β gene (ESR2) and the androgen receptor gene (AR) with colorectal cancer risk and prognosis. The ESR2 CA and AR CAG repeat polymorphisms were genotyped in 1798 cases (746 female, 1052 male) and 1810 controls (732 female, 1078 male), matched for sex, age and county of residence. Colorectal cancer risk associations overall and specific for gender were evaluated using multivariate logistic regression models adjusted for sex, county of residence and age. Associations with overall and disease-specific survival were evaluated using Cox proportional hazard models adjusted for established prognostic factors (diagnosis of other cancer after colorectal cancer diagnosis, detection by screening, treatment with adjuvant chemotherapy, tumour extent, nodal status, distant metastasis, body mass index, age at diagnosis and year of diagnosis) and stratified for grade of differentiation. Heterogeneity in gender specific associations was assessed by comparing models with and without a multiplicative interaction term by means of a likelihood ratio test. The average number of ESR2 CA repeats was associated with a small 5% increase in colorectal cancer risk (OR = 1.05, 95% CI 1.01-1.10) without significant heterogeneity according to gender or tumoural ESR2 expression. We found no indication for an association between the AR CAG repeat polymorphisms and risk of colorectal cancer. The ESR2 CA and AR CAG repeat polymorphisms were not associated with overall survival or disease specific survival after colorectal cancer diagnosis. Higher numbers of ESR2 CA repeats are potentially associated with a small increase in colorectal cancer risk. Our study does not support an association between colorectal cancer prognosis and the investigated repeat polymorphisms.

  12. Spatially-resolved measurement of optically stimulated luminescence and time-resolved luminescence

    International Nuclear Information System (INIS)

    Bailiff, I.K.; Mikhailik, V.B.

    2003-01-01

    Spatially-resolved measurements of optically stimulated luminescence (OSL) were performed using a two-dimensional scanning system designed for use with planar samples. The scanning system employs a focused laser beam to stimulate a selected area of the sample, which is moved under the beam by a motorised stage. Exposure of the sample is controlled by an electronic shutter. Mapping of the distribution of OSL using a continuous wave laser source was obtained with sub-millimeter resolution for samples of sliced brick, synthetic single crystal quartz, concrete and dental ceramic. These revealed sporadic emission in the case of brick or concrete and significant spatial variation of emission for quartz and dental ceramic slices. Determinations of absorbed dose were performed for quartz grains within a slice of modern brick. Reconfiguration of the scanner with a pulsed laser source enabled quartz and feldspathic minerals within a ceramic sample to be thinner region. about 6 nm from the extrapolation of themeasuring the time-resolved luminescence spectrum

  13. Compact cryogenic Kerr microscope for time-resolved studies of electron spin transport in microstructures

    NARCIS (Netherlands)

    Rizo, P. J.; Pugzlys, A.; Liu, J.; Reuter, D.; Wieck, A. D.; van der Wal, C. H.; van Loosdrecht, P. H. M.; Pugžlys, A.

    2008-01-01

    A compact cryogenic Kerr microscope for operation in the small volume of high-field magnets is described. It is suited for measurements both in Voigt and Faraday configurations. Coupled with a pulsed laser source, the microscope is used to measure the time-resolved Kerr rotation response of

  14. ESR study of radiation damage in pyrimidines. Progress report, August 1, 1975--April 1, 1976

    International Nuclear Information System (INIS)

    Benson, B.W.

    1976-04-01

    The primary objective of this project is to develop general mechanisms for radiation damage to biomolecules using substituted pyrimidines as a model system. Results this year include a single crystal ESR study of 5-ethyl-5-isopropylbarbituric acid, development of the k-band microwave bridge, dose response measurements on methylated barbituric acid derivatives, and synthesis of several specifically deuterated uracil derivatives

  15. Changes in molecular structure and properties of irradiated polymers of different compositions - ESR and NMR study

    International Nuclear Information System (INIS)

    Carswell-Pomerantz, T.; Babanalbandi, A.; Dong, L.; Hill, D.J.T.; Perera, M.C.S.; Pomery, P.J.; Saadat, G.; Whittaker, A.K.

    1999-01-01

    Investigations of molecular structural changes in polymers during exposure to high energy radiation is the long term interest of the Polymer Materials and Radiation Group at the University of Queensland. Recently, the group had looked at a range of polymers including natural and synthetic rubbers, methacrylates and polyesters. The objective of the work has been to investigate the relationships between polymer structure and sensitivity towards high energy radiation, including gamma radiation. This report will focus on the Electron Spin Resonance (ESR) and Nuclear Magnetic Resonance (NMR) studies of the effects of gamma irradiation on these polymers. Other methods such as Gas Chromatography (GC), Gel Permeation Chromatography (GPC), Fourier Transformed Infra Red (FTIR), Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TGA) and Dynamic Mechanical Analysis (DMA) have also been used as these methods combine with ESR and NMR, to provide a more complete picture of the mechanism of the structural changes. (author)

  16. From dating to biophysics -- 20 years of progress in applied ESR spectroscopy

    International Nuclear Information System (INIS)

    Regulla, Dieter

    2000-01-01

    ESR spectroscopy represents a tool for quantitative radiation analysis that was developed somehow simultaneously for dating purposes in Japan and in Germany for high-level standardization, in the mid-seventies. Meanwhile, ESR dosimetry has reached an established metrology level. Present research fields of ESR dosimetry consider post-accident dose reconstruction in the environment, and biophysical dosimetry using human tissues. The latter promises a re-definition of radiation risk for chronicle exposure to be derived from individuals of the early nuclear facilities in Russia, and hopefully United States in the future. An attempt is made to sketch development and potential future of the ESR technique

  17. Coherent optical effect on time-resolved vibrational SFG spectrum of adsorbates

    Science.gov (United States)

    Ueba, H.; Sawabu, T.; Mii, T.

    2002-04-01

    We present a theory to study the influence of the coherent mixing between pump-infrared and probe-visible pulse on a time-resolved sum-frequency generation (TR-SFG) spectrum for vibrations at surfaces. The general formula of the time-dependent and its Fourier transform of the SFG polarization and its Fourier transform allows us to calculate the time-resolved vibrational SFG spectrum and the transient characteristics of the SFG intensity as a function of the delay time td between the pump-infrared and probe-visible pulse. It is found the coherent optical effect manifests itself in the broadening and narrowing of the SFG spectrum with the intrinsic width of T2 at negative and positive td, respectively, being in qualitative agreement with recent experimental results. The influence of the coherent mixing on the transient behavior of the SFG intensity is also discussed in conjunction to the T2 determination.

  18. Simultaneous FT-NIR and ESR analysis to study of the kinetics of photo induced polymerization of vinyl radical polymers

    International Nuclear Information System (INIS)

    Le, T.T.; Hill, D.J.T.; Pomery, P.J.

    2000-01-01

    Full text:The rate parameters for free vinyl radical polymerizations are difficult to determine accurately over the whole range of conversion. For systems which polymerize rapidly and for networks, this is a particular problem, because small differences in polymerization conditions, e.g., temperature, initiator concentration, photon flux, etc., can cause a large change in the time evolution of the concentration of carbon double bonds and radicals if these are monitored in separate experiments. The IUPAC Working Party on the Modeling of kinetics and processes of polymerization has the role of recommending the 'best' values for the kinetic parameters, using pulsed-laser polymerization (PLP) in conjunction with molar mass distribution (MMD) to determine k p as a function of temperature (T deg C) for bulk free-radical polymerization of methyl methacrylate at low conversions and ambient temperature. The vinyl radical polymers used in this study were methyl methacrylate and ethylene glycol dimethacrylate. In the past kinetic studies of vinyl photo-polymerization required the time dependence of the monomer and radical concentrations to be monitored separately by using FT-NIR spectroscopy and ESR spectroscopy, respectively. For the systems which polymerize rapidly, small differences in the conditions for two measurements, e.g. temperature and light intensity, can introduce significant errors. Hyphenated experiments involving in-situ ESR and FT-NIR spectroscopies using fibre optic, can overcome these problems. In this paper, the radical and monomer concentrations were measured under the same experimental conditions using the above techniques. The results obtained were used to evaluate the kinetic parameters for free radical vinyl polymerizations

  19. Time-resolved luminescence studies in hydrogen uranyl phosphate intercalated with amines

    Energy Technology Data Exchange (ETDEWEB)

    Novo, Joao Batista Marques [Departamento de Quimica, Universidade Federal do Parana, CP 19081, 81531-990 Curitiba-PR (Brazil)]. E-mail: jbmnovo@quimica.ufpr.br; Batista, Fabio Roberto [Departamento de Quimica, Universidade Federal do Parana, CP 19081, 81531-990 Curitiba-PR (Brazil); Cunha, Carlos Jorge da [Departamento de Quimica, Universidade Federal do Parana, CP 19081, 81531-990 Curitiba-PR (Brazil); Dias, Lauro Camargo Jr. [Departamento de Quimica, Universidade Federal do Parana, CP 19081, 81531-990 Curitiba-PR (Brazil); Teixeira Pessine, Francisco Benedito [Instituto de Quimica, Universidade Estadual de Campinas, CP 6154, 13084-971 Campinas-SP (Brazil)

    2007-05-15

    Time-resolved luminescence decays of intercalated compounds of hydrogen uranyl phosphate (HUP) with p-toluidinium (HUPPT), benzylaminium (HUPBZ), {alpha}-methylbenzylaminium (HUPMBZ) and hydroxylaminium (HUPHAM) were studied. The prepared compounds belong to the tetragonal P4/ncc space group and showed 00 l reflections shifted to lower angles relative to HUP, indicating that the intercalation increases the c parameter of the unit cell. The luminescence decays of the compounds with 100% of intercalation ratio (HUPHAM and HUPBZ) were analyzed by Global Analysis, assuming Lianos' stretched exponential as the model function, which can be applied to compounds with restricted geometry and mobile donor and quencher molecules. It was remarkable that the luminescence decays showed that the quenching of the emission of the uranyl ions by the intercalated protonated amines is not restricted by low dimensionality of the host uranyl phosphate, and that a diffusion mechanism occurs. Benzylaminium cation efficiently quenches the excited energy of the uranyl ions at close distance, but the long-range and long-lifetime quenching is hindered. A different situation is found in the case of the small hydroxylaminium cation, where the long distance diffusion of the species is fast, playing an important role in the quenching of the excited uranyl ions at longer times.

  20. Time-resolved luminescence studies in hydrogen uranyl phosphate intercalated with amines

    International Nuclear Information System (INIS)

    Novo, Joao Batista Marques; Batista, Fabio Roberto; Cunha, Carlos Jorge da; Dias, Lauro Camargo Jr.; Teixeira Pessine, Francisco Benedito

    2007-01-01

    Time-resolved luminescence decays of intercalated compounds of hydrogen uranyl phosphate (HUP) with p-toluidinium (HUPPT), benzylaminium (HUPBZ), α-methylbenzylaminium (HUPMBZ) and hydroxylaminium (HUPHAM) were studied. The prepared compounds belong to the tetragonal P4/ncc space group and showed 00 l reflections shifted to lower angles relative to HUP, indicating that the intercalation increases the c parameter of the unit cell. The luminescence decays of the compounds with 100% of intercalation ratio (HUPHAM and HUPBZ) were analyzed by Global Analysis, assuming Lianos' stretched exponential as the model function, which can be applied to compounds with restricted geometry and mobile donor and quencher molecules. It was remarkable that the luminescence decays showed that the quenching of the emission of the uranyl ions by the intercalated protonated amines is not restricted by low dimensionality of the host uranyl phosphate, and that a diffusion mechanism occurs. Benzylaminium cation efficiently quenches the excited energy of the uranyl ions at close distance, but the long-range and long-lifetime quenching is hindered. A different situation is found in the case of the small hydroxylaminium cation, where the long distance diffusion of the species is fast, playing an important role in the quenching of the excited uranyl ions at longer times

  1. Direct access to dithiobenzoate RAFT agent fragmentation rate coefficients by ESR spin-trapping.

    Science.gov (United States)

    Ranieri, Kayte; Delaittre, Guillaume; Barner-Kowollik, Christopher; Junkers, Thomas

    2014-12-01

    The β-scission rate coefficient of tert-butyl radicals fragmenting off the intermediate resulting from their addition to tert-butyl dithiobenzoate-a reversible addition-fragmentation chain transfer (RAFT) agent-is estimated via the recently introduced electron spin resonance (ESR)-trapping methodology as a function of temperature. The newly introduced ESR-trapping methodology is critically evaluated and found to be reliable. At 20 °C, a fragmentation rate coefficient of close to 0.042 s(-1) is observed, whereas the activation parameters for the fragmentation reaction-determined for the first time-read EA = 82 ± 13.3 kJ mol(-1) and A = (1.4 ± 0.25) × 10(13) s(-1) . The ESR spin-trapping methodology thus efficiently probes the stability of the RAFT adduct radical under conditions relevant for the pre-equilibrium of the RAFT process. It particularly indicates that stable RAFT adduct radicals are indeed formed in early stages of the RAFT poly-merization, at least when dithiobenzoates are employed as controlling agents as stipulated by the so-called slow fragmentation theory. By design of the methodology, the obtained fragmentation rate coefficients represent an upper limit. The ESR spin-trapping methodology is thus seen as a suitable tool for evaluating the fragmentation rate coefficients of a wide range of RAFT adduct radicals. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Estimation of dose in irradiated chicken bone by ESR method

    International Nuclear Information System (INIS)

    Tanabe, Hiroko; Hougetu, Daisuke

    1998-01-01

    The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was γ-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated doses of chicken bones initially irradiated at 3.0kGy, 1.0kGy, 0.50kGy and 0.25kGy were 3.4kGy, 1.3kGy, 0.81kGy and 0.57kGy. (author)

  3. The Uncertainty estimation of Alanine/ESR dosimetry

    International Nuclear Information System (INIS)

    Kim, Bo Rum; An, Jin Hee; Choi, Hoon; Kim, Young Ki

    2008-01-01

    Machinery, tools and cable etc are in the nuclear power plant which environment is very severe. By measuring actual dose, it needs for extending life expectancy of the machinery and tools and the cable. Therefore, we estimated on dose (gamma ray) of Wolsong nuclear power division 1 by dose estimation technology for three years. The dose estimation technology was secured by ESR(Electron Spin Resonance) dose estimation using regression analysis. We estimate uncertainty for secure a reliability of results. The uncertainty estimation will be able to judge the reliability of measurement results. The estimation of uncertainty referred the international unified guide in order; GUM(Guide to the Expression of Uncertainty in Measurement). It was published by International Standardization for Organization (ISO) in 1993. In this study the uncertainty of e-scan and EMX those are ESR equipment were evaluated and compared. Base on these results, it will improve the reliability of measurement

  4. Programming for time resolved spectrum in pulse radiolysis experiments

    International Nuclear Information System (INIS)

    Betty, C.A.; Panajkar, M.S.; Shirke, N.D.

    1993-01-01

    A user friendly program in Pascal has been developed for data acquisition and subsequent processing of time resolved spectra of transient species produced in pulse radiolysis experiments. The salient features of the program are (i) thiocyanate dosimetry and (ii) spectrum acquisition. The thiocyanate dosimetry is carried out to normalize experimental conditions to a standard value as determined by computing absorbance of the transient signal CNS -2 that is produced from thiocyanate solution by a 7 MeV electron pulse. Spectrum acquisition allows the acquisition of the time resolved data at 20 different times points and subsequent display of the plots of absorbance vs. wavelength for the desired time points during the experiment. It is also possible to plot single time point spectrum as well as superimposed spectra for different time points. Printing, editing and merging facilities are also provided. (author). 2 refs., 7 figs

  5. Time-resolved crystallography using the Hadamard Transform

    Science.gov (United States)

    Yorke, Briony A.; Beddard, Godfrey S.; Owen, Robin L.; Pearson, Arwen R.

    2014-01-01

    A new method for performing time-resolved X-ray crystallographic experiments based on the Hadamard Transform is proposed and demonstrated. The time-resolution is defined by the underlying periodicity of the probe pulse sequence and the signal to noise is greatly improved compared to the fastest experiments depending on a single pulse. This approach is general and equally applicable to any spectroscopic or imaging measurement where the probe can be encoded. PMID:25282611

  6. Fast time-resolved electrostatic force microscopy: Achieving sub-cycle time resolution

    Energy Technology Data Exchange (ETDEWEB)

    Karatay, Durmus U.; Harrison, Jeffrey S.; Glaz, Micah S.; Giridharagopal, Rajiv; Ginger, David S., E-mail: ginger@chem.washington.edu [Department of Chemistry, University of Washington, Seattle, Washington 98195 (United States)

    2016-05-15

    The ability to measure microsecond- and nanosecond-scale local dynamics below the diffraction limit with widely available atomic force microscopy hardware would enable new scientific studies in fields ranging from biology to semiconductor physics. However, commercially available scanning-probe instruments typically offer the ability to measure dynamics only on time scales of milliseconds to seconds. Here, we describe in detail the implementation of fast time-resolved electrostatic force microscopy using an oscillating cantilever as a means to measure fast local dynamics following a perturbation to a sample. We show how the phase of the oscillating cantilever relative to the perturbation event is critical to achieving reliable sub-cycle time resolution. We explore how noise affects the achievable time resolution and present empirical guidelines for reducing noise and optimizing experimental parameters. Specifically, we show that reducing the noise on the cantilever by using photothermal excitation instead of piezoacoustic excitation further improves time resolution. We demonstrate the discrimination of signal rise times with time constants as fast as 10 ns, and simultaneous data acquisition and analysis for dramatically improved image acquisition times.

  7. Time resolved resonant inelastic X-ray scattering: A supreme tool to understand dynamics in solids and molecules

    International Nuclear Information System (INIS)

    Beye, M.; Wernet, Ph.; Schüßler-Langeheine, C.; Föhlisch, A.

    2013-01-01

    Highlights: •The high specificity of RIXS ideally suits time-resolved measurements. •Methods relating to the core hole lifetime cover the low femtosecond regime. •Pump-probe methods are used starting at sub-ps time scales. •FELs and synchrotrons are useful for pump-probe studies. •Examples from solid state dynamics and molecules are discussed. -- Abstract: Dynamics in materials typically involve different degrees of freedom, like charge, lattice, orbital and spin in a complex interplay. Time-resolved resonant inelastic X-ray scattering (RIXS) as a highly selective tool can provide unique insight and follow the details of dynamical processes while resolving symmetries, chemical and charge states, momenta, spin configurations, etc. In this paper, we review examples where the intrinsic scattering duration time is used to study femtosecond phenomena. Free-electron lasers access timescales starting in the sub-ps range through pump-probe methods and synchrotrons study the time scales longer than tens of ps. In these examples, time-resolved resonant inelastic X-ray scattering is applied to solids as well as molecular systems

  8. Time-resolved homo-FRET studies of biotin-streptavidin complexes.

    Science.gov (United States)

    Andreoni, Alessandra; Nardo, Luca; Rigler, Rudolf

    2016-09-01

    Förster resonance energy transfer is a mechanism of fluorescence quenching that is notably useful for characterizing properties of biomolecules and/or their interactions. Here we study water-solutions of Biotin-Streptavidin complexes, in which Biotin is labeled with a rigidly-bound fluorophore that can interact by Förster resonance energy transfer with the fluorophores labeling the other, up to three, Biotins of the same complex. The fluorophore, Atto550, is a Rhodamine analogue. We detect the time-resolved fluorescence decay of the fluorophores with an apparatus endowed with single-photon sensitivity and temporal resolution of ~30ps. The decay profiles we observe for samples containing constant Biotin-Atto550 conjugates and varying Streptavidin concentrations are multi-exponential. Each decay component can be associated with the rate of quenching exerted on each donor by each of the acceptors that label the other Biotin molecules, depending on the binding site they occupy. The main features that lead to this result are that (i) the transition dipole moments of the up-to-four Atto550 fluorophores that label the complexes are fixed as to both relative positions and mutual orientations; (ii) the fluorophores are identical and the role of donor in each Biotin-Streptavidin complex is randomly attributed to the one that has absorbed the excitation light (homo-FRET). Obviously the high-temporal resolution of the excitation-detection apparatus is necessary to discriminate among the fluorescence decay components. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. High Energy Electron Dosimetry by Alanine/ESR Spectroscopy

    International Nuclear Information System (INIS)

    Chu, Sung Sil

    1989-01-01

    Dosimetry based on electron spin resonance(ESR) analysis of radiation induced free radicals in amino acids is relevant to biological dosimetry applications. Alanine detectors are without walls and are tissue equivalent. Therefore, alanine ESR dosimetry looks promising for use in the therapy level. The dose range of the alanine/ESR dosimetry system can be extended down to l Gy. In a water phantom the absorbed dose of electrons generated by a medical linear accelerator of different initial energies (6-21 MeV) and therapeutic dose levels(1-60 Gy) was measured. Furthermore, depth dose measurements carried out with alanine dosimeters were compared with ionization chamber measurements. As the results, the measured absorbed doses for shallow depth of initial electron energies above 15 MeV were higher by 2-5% than those calculated by nominal energy CE factors. This seems to be caused by low energy scattered beams generated from the scattering foil and electron cones of beam projecting device in medical linear accelerator

  10. Dynamic crossovers and activated regimes in a narrow distribution poly(n-butyl acrylate): an ESR study

    Energy Technology Data Exchange (ETDEWEB)

    Andreozzi, Laura; Autiero, Ciro; Faetti, Massimo; Giordano, Marco; Zulli, Fabio [Department of Physics ' E Fermi' , University of Pisa, largo Pontecorvo 3, 56127 Pisa (Italy); polyLAB-CNR, largo Pontecorvo 3, 56127 Pisa (Italy)

    2006-07-19

    The rotational dynamics of the spin probe cholestane dissolved in a narrow distribution poly(n-butyl acrylate) sample has been investigated via electron spin resonance (ESR) spectroscopy. The measurements were carried out in a wide temperature range: different dynamic regions have been recognized, and the coupling of the probe dynamics to the {alpha} and secondary relaxations has been revealed. In particular, the coupling with the structural relaxation is ruled by two fractionary Vogel-Fulcher laws (VF). The crossover from one VF region to the other occurs at the temperature T{sub C} = 1.17T{sub g}, signalling the onset of the cooperativity in the dynamics and confirming a behaviour previously observed in ESR studies carried out on polymeric glass-formers. Furthermore, in this work we discuss the activated regime at the highest temperatures and show that the activation energy does not depend on the length of the polymer main- and side-chains, while its onset temperature linearly depends on the chain length.

  11. Dynamic crossovers and activated regimes in a narrow distribution poly(n-butyl acrylate): an ESR study

    International Nuclear Information System (INIS)

    Andreozzi, Laura; Autiero, Ciro; Faetti, Massimo; Giordano, Marco; Zulli, Fabio

    2006-01-01

    The rotational dynamics of the spin probe cholestane dissolved in a narrow distribution poly(n-butyl acrylate) sample has been investigated via electron spin resonance (ESR) spectroscopy. The measurements were carried out in a wide temperature range: different dynamic regions have been recognized, and the coupling of the probe dynamics to the α and secondary relaxations has been revealed. In particular, the coupling with the structural relaxation is ruled by two fractionary Vogel-Fulcher laws (VF). The crossover from one VF region to the other occurs at the temperature T C = 1.17T g , signalling the onset of the cooperativity in the dynamics and confirming a behaviour previously observed in ESR studies carried out on polymeric glass-formers. Furthermore, in this work we discuss the activated regime at the highest temperatures and show that the activation energy does not depend on the length of the polymer main- and side-chains, while its onset temperature linearly depends on the chain length

  12. Broad-band time-resolved near infrared spectroscopy in the TJ-II stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, M.C.; Pastor, I.; Cal, E. de la; McCarthy, K.J. [Laboratorio Nacional de Fusion, CIEMAT, Madrid (Spain); Diaz, D. [Universidad Autonoma de Madrid, Dept Quimica Fisica Aplicada, Madrid (Spain)

    2014-11-15

    First experimental results on broad-band, time-resolved Near Infrared (NIR;here loosely defined as covering from 750 to 1650 nm) passive spectroscopy using a high sensitivity InGaAs detector are reported for the TJ-II Stellarator. Experimental set-up is described together with its main characteristics, the most remarkable ones being its enhanced NIR response, broadband spectrum acquisition in a single shot, and time-resolved measurements with up to 1.8 kHz spectral rate. Prospects for future work and more extended physics studies in this newly open spectral region in TJ-II are discussed. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. In-pile Thermal Conductivity Characterization with Time Resolved Raman

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xinwei [Iowa State Univ., Ames, IA (United States). Dept. of Mechanical Engineering; Hurley, David H. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2018-03-19

    The project is designed to achieve three objectives: (1) Develop a novel time resolved Raman technology for direct measurement of fuel and cladding thermal conductivity. (2) Validate and improve the technology development by measuring ceramic materials germane to the nuclear industry. (3) Conduct instrumentation development to integrate optical fiber into our sensing system for eventual in-pile measurement. We have developed three new techniques: time-domain differential Raman (TD-Raman), frequency-resolved Raman (FR-Raman), and energy transport state-resolved Raman (ET-Raman). The TD-Raman varies the laser heating time and does simultaneous Raman thermal probing, the FR-Raman probes the material’s thermal response under periodical laser heating of different frequencies, and the ET-Raman probes the thermal response under steady and pulsed laser heating. The measurement capacity of these techniques have been fully assessed and verified by measuring micro/nanoscale materials. All these techniques do not need the data of laser absorption and absolute material temperature rise, yet still be able to measure the thermal conductivity and thermal diffusivity with unprecedented accuracy. It is expected they will have broad applications for in-pile thermal characterization of nuclear materials based on pure optical heating and sensing.

  14. Simple method for quantification of gadolinium magnetic resonance imaging contrast agents using ESR spectroscopy.

    Science.gov (United States)

    Takeshita, Keizo; Kinoshita, Shota; Okazaki, Shoko

    2012-01-01

    To develop an estimation method of gadolinium magnetic resonance imaging (MRI) contrast agents, the effect of concentration of Gd compounds on the ESR spectrum of nitroxyl radical was examined. A solution of either 4-oxo-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPONE) or 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPOL) was mixed with a solution of Gd compound and the ESR spectrum was recorded. Increased concentration of gadolinium-diethylenetriamine pentaacetic acid chelate (Gd-DTPA), an MRI contrast agent, increased the peak-to-peak line widths of ESR spectra of the nitroxyl radicals, in accordance with a decrease of their signal heights. A linear relationship was observed between concentration of Gd-DTPA and line width of ESR signal, up to approximately 50 mmol/L Gd-DTPA, with a high correlation coefficient. Response of TEMPONE was 1.4-times higher than that of TEMPOL as evaluated from the slopes of the lines. The response was slightly different among Gd compounds; the slopes of calibration curves for acua[N,N-bis[2-[(carboxymethyl)[(methylcarbamoyl)methyl]amino]ethyl]glycinato(3-)]gadolinium hydrate (Gd-DTPA-BMA) (6.22 μT·L/mmol) and gadolinium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid chelate (Gd-DOTA) (6.62 μT·L/mmol) were steeper than the slope for Gd-DTPA (5.45 μT·L/mmol), whereas the slope for gadolinium chloride (4.94 μT·L/mmol) was less steep than that for Gd-DTPA. This method is simple to apply. The results indicate that this method is useful for rough estimation of the concentration of Gd contrast agents if calibration is carried out with each standard compound. It was also found that the plot of the reciprocal square root of signal height against concentrations of contrast agents could be useful for the estimation if a constant volume of sample solution is taken and measured at the same position in the ESR cavity every time.

  15. Multi-Channel Amplifier-Discriminator for Highly Time-Resolved Detection

    CERN Document Server

    Despeisse, M; Lapington, J; Jarron, P

    2011-01-01

    A low-power multi-channel amplifier-discriminator was developed for application in highly time-resolved detection systems. The proposed circuit architecture, so-called Nino, is based on a time-over-threshold approach and shows a high potential for time-resolved readout of solid-state photo-detectors and of detectors based on vacuum technologies. The Irpics circuit was designed in a 250 nm CMOS technology, implementing 32 channels of a Nino version optimized to achieve high-time resolution on the output low-voltage differential signals (LVDS) while keeping a low power consumption of 10 mW per channel. Electrical characterizations of the circuit demonstrate a very low intrinsic time jitter on the output pulse leading edge, measured below 10 ps rms for each channel for high input signal charges (100 fC) and below 25 ps rms for low input signal charges (20-100 fC). The read-out architecture moreover permits to retrieve the input signal charge from the timing measurements, while a calibration procedure was develop...

  16. New Approach For Detection Of Irradiated Spices Using Electron Spin Resonance (ESR)

    International Nuclear Information System (INIS)

    FARAG, S.A.; SHAMS EL DIEEN, N.M.M.

    2010-01-01

    Black pepper and anise samples were irradiated with different doses of gamma rays (5, 10 and 20 kGy) then the irradiated samples were stored at room temperature (20 0 C, 70-75 % RH) for one year. The measurements of free radicals were carried out by electron spin resonance (ESR) at different intervals (3, 6, 9 and 12 months). A series of signals tentatively described as cellulose-like and complex radical observed at G values were 2.01027 for black pepper and 2.01019 for anise. The ESR signals of irradiated spices showed a directly proportional relationship for increasing dose with increasing intensity of signal. A relationship was noticed as polynomial regression analysis resulted between signals of ESR intensity and applied doses with significant values of correlation coefficient (R 2 ). All combination treatments of thermal and irradiation beside long storage caused significant reduction of ESR intensity of irradiated black pepper and anise. Upon using low doses as 1, 2 and 3 kGy for re-irradiation, the irradiated samples (10 and 20 kGy) increased the power of ESR intensity. The enhancement effect was markedly increased. For example, the irradiated black pepper (10 kGy) increased the ESR intensity with high percentages as 49.19%, 69.23% and 89.68% while the high dose (20 kGy) caused increase by 39.96%, 69.05% and 96.90% for irradiated black pepper samples. This approach with that technique can be used easily to overcome the main disadvantages of ESR signals fading especially at the end of storage period.

  17. Physics book: CRYRING'a'ESR

    International Nuclear Information System (INIS)

    Lestinsky, M.; Aurand, B.; Bagnoud, V.; Andrianov, V.

    2016-01-01

    CRYRING is a heavy ion storage ring, formerly located in Stockholm University. During close to two decades of operation in Sweden, many significant scientific contributions to atomic and molecular physics were achieved using CRYRING. To further leverage its capabilities into the realm of intense beams of highly charged ions, of exotic isotopes, and antiprotons, it has for long been proposed to relocate CRYRING from Sweden to GSI/FAIR, which is the CRYRING'a'ESR project. In Darmstadt, the ring is being modernized and adapted to the GSI/FAIR standards and set up downstream of ESR. In the different chapters we sketch out a broad scientific program in the fields of atomic and nuclear physics and at their intersection. The realization will allow for exciting high-precision spectroscopy studies of atomic systems and their dynamics where special emphasis is given to the effects of quantum electrodynamics (QED) and electron-correlation in the strong field domain (Chap. 2). The intersection of atomic and nuclear physics is addressed where the imprint of nuclear effects on the electronic shell are investigated with spectroscopic methods (Chap. 3), and exploring the nuclear structure, nuclear dynamical processes and quantitative measurements of astrophysically relevant (p, γ)-reaction rates (Chap. 4). These experiments are of prime interest for testing modern theoretical methods on fundamental processes as well as for applications in astrophysics and for modelling plasmas. In the domain of slow collisions in of heavy ions at highest charge-states where atomic processes are prevailed by large perturbations, these studies are expected to refine substantially our understanding of the physics of extreme electromagnetic fields. Also, CRYRINGaESR will offer extracted high-quality ion beams, thus enabling novel research opportunities for external-target experiments with slow highly-charged ions. The experimental boundary conditions and suggested future instrumentation

  18. ESR studies of electron irradiated K3Ir(CN)6 in KCl single crystals

    International Nuclear Information System (INIS)

    Vugman, N.V.; Pinhal, N.M.

    1983-01-01

    ESR studies of KCl single crystals doped with small amounts of K 3 Ir(CN) 6 and submitted to a prolongued 2 MeV electron irradiation at room temperature reveal the presence of the [IR(CN) 5 Cl] 4- and [Ir(CN) 4 Cl 2 ] 4- new molecular species. Ligand spin densities and ligand field parameters are calculated from the experimental hyperfine and superhyperfine interactions and compared to previous data on the [Ir(CN) 5 ] 4- species. (Author) [pt

  19. In situ ESR/UV-vis-NIR and ATR-FTIR spectroelectrochemical studies on the p-doping of copolymers of 3-methylthiophene and 3-hexylthiophene.

    Science.gov (United States)

    Cházaro-Ruiz, Luis F; Kellenberger, Andrea; Dunsch, Lothar

    2009-02-26

    A combined spectroelectrochemical study by ESR/UV-vis-NIR as well as FTIR spectroscopy on the influence of the copolymer composition on the stabilization of charges upon electrochemical p-doping is presented. As compared to the parent homopolymers 3-hexylthiophene (3-HeTh) and 3-methylthiophene (3-MeTh) which seems to be irregular, FTIR studies of the copolymer of both monomers (copMeHeTh) point to a regioregular structure. The in situ ESR and UV-vis-NIR spectroelectrochemistry at higher doping levels of the polymeric materials proves bipolarons and polaron pairs as stable charged states in poly(3-hexylthiophene) as well as the copolymer copMeHeTh. During the p-doping of poly(3-methylthiophene) bipolarons are the dominating species at higher doping levels. It is demonstrated that only the simultaneous use of both the ESR and the UV-vis-NIR spectroscopy enables the differentiation of polarons (paramagnetic) and polaron pairs (diamagnetic) in a conducting polymer.

  20. Expression of estrogen receptor α 36 (ESR36) in the hamster ovary throughout the estrous cycle: effects of gonadotropins.

    Science.gov (United States)

    Chakraborty, Prabuddha; Roy, Shyamal K

    2013-01-01

    Estradiol-17β (E) plays an important role in ovarian follicular development. Evidence indicates that some of the effect of E is mediated by the transmembrane estrogen receptor. In this study, we examined the spatio-temporal expression of recently discovered ERα36 (ESR36), a splice variant of Esr1 and a receptor for non-genomic E signaling, in the hamster ovary during the estrous cycle and the role of gonadotropins and ovarian steroid hormones in ESR36 expression. ESR36 expression was high on estrus (D1:0900 h) and declined precipitously by proestrus (D4:0900 h) and remained low up to D4:1600 h. Immunofluorescence findings corroborated immunoblot findings and revealed that ESR36 was expressed only in the cell membrane of both follicular and non-follicular cells, except the oocytes. Ovarian ESR36 was capable of binding to the E-affinity matrix, and have different molecular weight than that of the ESR1 or GPER. Hypophysectomy (Hx) resulted in a marked decline in ESR36 protein levels. FSH and LH, alone or combined, markedly upregulated ESR36 protein in Hx hamsters to the levels observed in D1 hamsters, but neither E nor P had any effect. Inhibition of the gonadotropin surge by phenobarbital treatment on D4:1100 h attenuated ESR36 expression in D1:0900 h ovaries, but the decline was restored by either FSH or LH replacement on D4 afternoon. This is the first report to show that ESR36, which is distinct from ESR1 or GPER is expressed in the plasma membrane of ovarian follicular and non-follicular cells, binds to E and its expression is regulated directly by the gonadotropins. In light of our previous findings, the results suggest that ovarian cells contain at least two distinct membrane estrogen receptors, such as GPER and ESR36, and strongly suggest for a non-genomic action of E regulating ovarian follicular functions.

  1. Expression of estrogen receptor α 36 (ESR36 in the hamster ovary throughout the estrous cycle: effects of gonadotropins.

    Directory of Open Access Journals (Sweden)

    Prabuddha Chakraborty

    Full Text Available Estradiol-17β (E plays an important role in ovarian follicular development. Evidence indicates that some of the effect of E is mediated by the transmembrane estrogen receptor. In this study, we examined the spatio-temporal expression of recently discovered ERα36 (ESR36, a splice variant of Esr1 and a receptor for non-genomic E signaling, in the hamster ovary during the estrous cycle and the role of gonadotropins and ovarian steroid hormones in ESR36 expression. ESR36 expression was high on estrus (D1:0900 h and declined precipitously by proestrus (D4:0900 h and remained low up to D4:1600 h. Immunofluorescence findings corroborated immunoblot findings and revealed that ESR36 was expressed only in the cell membrane of both follicular and non-follicular cells, except the oocytes. Ovarian ESR36 was capable of binding to the E-affinity matrix, and have different molecular weight than that of the ESR1 or GPER. Hypophysectomy (Hx resulted in a marked decline in ESR36 protein levels. FSH and LH, alone or combined, markedly upregulated ESR36 protein in Hx hamsters to the levels observed in D1 hamsters, but neither E nor P had any effect. Inhibition of the gonadotropin surge by phenobarbital treatment on D4:1100 h attenuated ESR36 expression in D1:0900 h ovaries, but the decline was restored by either FSH or LH replacement on D4 afternoon. This is the first report to show that ESR36, which is distinct from ESR1 or GPER is expressed in the plasma membrane of ovarian follicular and non-follicular cells, binds to E and its expression is regulated directly by the gonadotropins. In light of our previous findings, the results suggest that ovarian cells contain at least two distinct membrane estrogen receptors, such as GPER and ESR36, and strongly suggest for a non-genomic action of E regulating ovarian follicular functions.

  2. Difference structures from time-resolved small-angle and wide-angle x-ray scattering

    Science.gov (United States)

    Nepal, Prakash; Saldin, D. K.

    2018-05-01

    Time-resolved small-angle x-ray scattering/wide-angle x-ray scattering (SAXS/WAXS) is capable of recovering difference structures directly from difference SAXS/WAXS curves. It does so by means of the theory described here because the structural changes in pump-probe detection in a typical time-resolved experiment are generally small enough to be confined to a single residue or group in close proximity which is identified by a method akin to the difference Fourier method of time-resolved crystallography. If it is assumed, as is usual with time-resolved structures, that the moved atoms lie within the residue, the 100-fold reduction in the search space (assuming a typical protein has about 100 residues) allows the exaction of the structure by a simulated annealing algorithm with a huge reduction in computing time and leads to a greater resolution by varying the positions of atoms only within that residue. This reduction in the number of potential moved atoms allows us to identify the actual motions of the individual atoms. In the case of a crystal, time-resolved calculations are normally performed using the difference Fourier method, which is, of course, not directly applicable to SAXS/WAXS. The method developed in this paper may be thought of as a substitute for that method which allows SAXS/WAXS (and hence disordered molecules) to also be used for time-resolved structural work.

  3. Effects of sphingosine and sphingosine analogues on the free radical production by stimulated neutrophils: ESR and chemiluminescence studies

    Directory of Open Access Journals (Sweden)

    A. Mouithys-Mickalad

    1997-01-01

    Full Text Available Sphingolipids inhibit the activation of the neutrophil (PMN NADPH oxidase by protein kinase C pathway. By electron spin resonance spectroscopy (ESR and chemiluminescence (CL, we studied the effects of sphingosine (SPN and ceramide analogues on phorbol 12-myristate 13-acetate (PMA, 5 × 10-7M stimulated PMN (6 × 106 cells. By ESR with spin trapping (100 mM DMPO: 5,5-dimethyl-1-pyrroline-Noxide, we showed that SPN (5 to 8 × 10-6M, C2-ceramide (N-acetyl SPN and C6-ceramide (N-hexanoyl SPN at the final concentration of 2 × 10-5 and 2 × 10-4M inhibit the production of free radicals by stimulated PMN. The ESR spectrum of stimulated PMN was that of DMPO-superoxide anion spin adduct. Inhibition by 5 × 10-6M SPN was equivalent to that of 30 U/ml SOD. SPN (5 to 8 × 10-6M has no effect on in vitro systems generating superoxide anion (xanthine 50 mM/xanthine oxidase 110 mU/ml or hydroxyl radical (Fenton reaction: 88 mM H2O2, 0.01 mM Fe2+ and 0.01 mM EDTA. SPN and N-acetyl SPN also inhibited the CL of PMA stimulated PMN in a dose dependent manner (from 2 × 10-6 to 10-5M, but N-hexanoyl SPN was less active (from 2 × 10-5 to 2 × 10-4M. These effects were compared with those of known PMN inhibitors, superoxide dismutase, catalase and azide. SPN was a better inhibitor compared with these agents. The complete inhibition by SPN of ESR signal and CL of stimulated PMN confirms that this compound or one of its metabolites act at the level of NADPH-oxidase, the key enzyme responsible for production of oxygen-derived free radicals.

  4. The Oxford-Diamond In Situ Cell for studying chemical reactions using time-resolved X-ray diffraction

    Science.gov (United States)

    Moorhouse, Saul J.; Vranješ, Nenad; Jupe, Andrew; Drakopoulos, Michael; O'Hare, Dermot

    2012-08-01

    A versatile, infrared-heated, chemical reaction cell has been assembled and commissioned for the in situ study of a range of chemical syntheses using time-resolved energy-dispersive X-ray diffraction (EDXRD) on Beamline I12 at the Diamond Light Source. Specialized reactor configurations have been constructed to enable in situ EDXRD investigation of samples under non-ambient conditions. Chemical reactions can be studied using a range of sample vessels such as alumina crucibles, steel hydrothermal autoclaves, and glassy carbon tubes, at temperatures up to 1200 °C.

  5. Time-resolved fluorescence study of exciplex formation in diastereomeric naproxen-pyrrolidine dyads.

    Science.gov (United States)

    Khramtsova, Ekaterina A; Plyusnin, Viktor F; Magin, Ilya M; Kruppa, Alexander I; Polyakov, Nikolay E; Leshina, Tatyana V; Nuin, Edurne; Marin, M Luisa; Miranda, Miguel A

    2013-12-19

    The influence of chirality on the elementary processes triggered by excitation of the (S,S)- and (R,S)- diastereoisomers of naproxen-pyrrolidine (NPX-Pyr) dyads has been studied by time-resolved fluorescence in acetonitrile-benzene mixtures. In these systems, the quenching of the (1)NPX*-Pyr singlet excited state occurs through electron transfer and exciplex formation. Fluorescence lifetimes and quantum yields revealed a significant difference (around 20%) between the (S,S)- and (R,S)- diastereomers. In addition, the quantum yields of exciplexes differed by a factor of 2 regardless of solvent polarity. This allows us to suggest a similar influence of the chiral centers on the local charge transfer resulting in exciplex and full charge separation that leads to ion-biradicals. A simplified scheme is proposed to estimate a set of rate constant values (k1-k5) for the elementary stages in each solvent system.

  6. ESR1 Gene Polymorphisms and Prostate Cancer Risk: A HuGE Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Yu-Mei Wang

    Full Text Available Many published data on the association between single nucleotide polymorphisms (SNPs in the ESR1 gene and prostate cancer susceptibility are inconclusive. The aim of this Human Genome Epidemiology (HuGE review and meta-analysis is to derive a more precise estimation of this relationship.A literature search of PubMed, Embase, Web of Science and Chinese Biomedical (CBM databases was conducted from their inception through July 1st, 2012. Crude odds ratios (ORs with 95% confidence intervals (CIs were calculated to assess the strength of association.Twelve case-control studies were included with a total 2,165 prostate cancer cases and 3,361 healthy controls. When all the eligible studies were pooled into the meta-analysis, ESR1 PvuII (C>T and XbaI (A>G polymorphisms showed no association with the risk of prostate cancer. However, in the stratified analyses based on ethnicity and country, the results indicated that ESR1 PvuII (C>T polymorphism was significantly associated with increased risk of prostate cancer among Asian populations, especially among Indian population; while ESR1 XbaI (A>G polymorphism may significantly increase the risk of prostate cancer among American population. Furthermore, we also performed a pooled analysis for all eligible case-control studies to explore the role of codon 10 (T>C, codon 325 (C>G, codon 594 (G>A and +261G>C polymorphisms in prostate cancer risk. Nevertheless, no significant associations between these polymorphisms and the risk of prostate cancer were observed.Results from the current meta-analysis indicate that ESR1 PvuII (C>T polymorphism may be a risk factor for prostate cancer among Asian populations, especially among Indian population; while ESR1 XbaI (A>G polymorphism may increase the risk of prostate cancer among American population.

  7. A study for association and interaction analysis to metabolic syndrome and the ESR1 gene on cardiovascular autonomic neuropathy in a Chinese Han population.

    Science.gov (United States)

    Zeng, Fangfang; Zhou, Linuo; Tang, Zihui

    2016-01-01

    The aim of this study was to investigate the association and interaction of metabolic syndrome (MetS) and estrogen receptor alpha 1 (ESR1) gene polymorphisms on cardiovascular autonomic neuropathy (CAN). A large-scale, population-based study was conducted to analyze the interaction of MetS and ESR1 gene polymorphisms to CAN, including a total of 1977 Chinese subjects. The most common studied single nucleotide polymorphism of ESR1 gene-rs9340799, was genotyped. Multiple logistic regression (MLR) was performed to evaluate the interaction effect of environmental variables and gene polymorphisms. Interaction on an additive scale can be calculated by using the relative excess risk due to interaction (RERI), the proportion attributable to interaction (AP), and the synergy index (S). After controlling potential confounders, MLR showed that significant association between MetS and CAN (p interaction was estimated by using RETI = 0.396 (95 % CI 0.262 to 0.598), AP = 0.216 (95 % CI -0.784 to 1.216) and S = 1.906 (95 % CI 0.905 to 4.015). The present findings suggest that MetS is significantly associated with CAN and provide evidence for the hypothesis that MetS and ESR1 gene polymorphism (rs9340799) have interactive effects on CAN. ClinicalTrials gov Identifier NCT02461342.

  8. Attempt at ESR dating of tooth enamel of French middle pleistocene sites

    International Nuclear Information System (INIS)

    Bahain, J.J.; Sarcia, M.N.; Falgueres, C.; Yokoyama, Y.

    1993-01-01

    Tooth enamel samples from four important French middle Pleistocene sites are analyzed by the ESR method. ESR ages were calculated using uranium uptake mathematical models and compared with U-series results. (author)

  9. Detection of gamma-irradiated peanuts by ESR spectroscopy and GC analysis of hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Wei Mingli; An Li [Institute of Agro-food Science and Technology, Chinese Academy of Agricultural Sciences, 100193 Beijing (China); Yi Mingha, E-mail: wangyilwm@163.co [Institute of Agro-food Science and Technology, Chinese Academy of Agricultural Sciences, 100193 Beijing (China); Feng Wang [Institute of Agro-food Science and Technology, Chinese Academy of Agricultural Sciences, 100193 Beijing (China); Yan Lizhang [Division of Metrology in Ionizing Radiation and Medicine, National Institute of Metrology, 100013 Beijing (China)

    2011-03-15

    Peanuts were analyzed by electron spin resonance (ESR) spectroscopy and gas chromatography (GC) before and after gamma irradiation. Using European protocols, the validity and effectiveness of these two techniques were compared with regard to sample preparation, sample and solvent consumption and dose-response curves after irradiation. The results showed the possibility of using ESR and GC for distinguishing between irradiated and unirradiated peanuts. A radiation dose of 0.1 kGy could be detected by ESR but not by GC. The results also indicated that GC is an effective method for qualitative analysis of irradiated peanut, while ESR is suitable for the rapid detection of irradiated peanuts.

  10. Time-resolved study of formate on Ni( 1 1 1 ) by picosecond SFG spectroscopy

    Science.gov (United States)

    Kusafuka, K.; Noguchi, H.; Onda, K.; Kubota, J.; Domen, K.; Hirose, C.; Wada, A.

    2002-04-01

    Time-resolved vibrational measurements were carried out on formate (HCOO) adsorbed on Ni(1 1 1) surface by combining the sum-frequency generation method and picosecond laser system (time resolution of 6 ps). Rapid intensity decrease (within the time resolution) followed by intensity recovery (time constant of several tens of ps) of CH stretching signal was observed when picosecond 800 nm pulse was irradiated on the sample surface. From the results of temperature and pump fluence dependences of temporal behaviour of signal intensity, we concluded that the observed intensity change was induced by non-thermal process. Mechanism of the temporal intensity change was discussed.

  11. On the connection of the ESR characteristics of zircons with the degree of their defectiveness

    International Nuclear Information System (INIS)

    Matyash, I.V.; Brik, A.E.; Derski, L.S.; Larikov, A.L.; Ponomarenko, A.N.

    1989-01-01

    The dynamic characteristics of the electron-hole centres (EHC) in zircons with various degree of defectiveness have been studied. Crystalline and amorphous regions are typical of different sets of EHC, having essentially different relaxation characteristics. Lack of cross-relaxation between these centres shows that they are localized in different parts of the crystal. The influence of autoirradiation and of corresponding defectiveness of the matrix upon the intensity of the EHC signals (V i ) has been studied. In the specimens of high crystallinity V i increases as the content of radioactive elements and defectiveness increases. In the essentially metamict specimens the situation reverses. Interpretation of this effect is given considering the dose dependence of the ESR signals and the ratio of the crystal and metamict volumes in the studied object. The transformations of the EHC set is traced along the amorphization of the zircon matrix due to the autoirradiation. ESR signals corresponding to different phases in zircon have been recorded. The correlation of the zircon grain size and the static magnetic susceptibility with V i have been studied. In the specimens of high crystallinity such correlation is absent and in metamict specimens the intensities V i decrease as the grain sizes decrease. The interpretation of this fact is proposed. It has been shown that the ESR studies reflect the processes of income and migration of the impurity elements in zircons and the ways of the zircon crystal matrix decay in a geological time scale. The factors controlling such a decay have been found. (author)

  12. Electron spin resonance (ESR) spectroscopy applied to radiation dosimetry and other fields

    International Nuclear Information System (INIS)

    Schneider, C.C.J.

    1994-12-01

    A short introduction to the theory and practice of ESR spectroscopy is given. ESR alanine dosimetry for low and high LET (linear energy transfer) ionising radiation is described, indicating its advantages over traditional methods. Problems arising in the therapy dose range (below 5 Gy), and possible future developments, are mentioned. The application of ESR to the radiation processing of materials and foodstuffs, to geological dating, biology, molecular chemistry and to medicine is discussed. Some examples of chemical analyses are also presented. (orig.)

  13. Studying the potential of point detectors in time-resolved dose verification of dynamic radiotherapy

    International Nuclear Information System (INIS)

    Beierholm, A.R.; Behrens, C.F.; Andersen, C.E.

    2015-01-01

    Modern megavoltage x-ray radiotherapy with high spatial and temporal dose gradients puts high demands on the entire delivery system, including not just the linear accelerator and the multi-leaf collimator, but also algorithms used for optimization and dose calculations, and detectors used for quality assurance and dose verification. In this context, traceable in-phantom dosimetry using a well-characterized point detector is often an important supplement to 2D-based quality assurance methods based on radiochromic film or detector arrays. In this study, an in-house developed dosimetry system based on fiber-coupled plastic scintillator detectors was evaluated and compared with a Farmer-type ionization chamber and a small-volume ionization chamber. An important feature of scintillator detectors is that the sensitive volume of the detector can easily be scaled, and five scintillator detectors of different scintillator length were thus employed to quantify volume averaging effects by direct measurement. The dosimetric evaluation comprised several complex-shape static fields as well as simplified dynamic deliveries using RapidArc, a volumetric-modulated arc therapy modality often used at the participating clinic. The static field experiments showed that the smallest scintillator detectors were in the best agreement with dose calculations, while needing the smallest volume averaging corrections. Concerning total dose measured during RapidArc, all detectors agreed with dose calculations within 1.1 ± 0.7% when positioned in regions of high homogenous dose. Larger differences were observed for high dose gradient and organ at risk locations, were differences between measured and calculated dose were as large as 8.0 ± 5.5%. The smallest differences were generally seen for the small-volume ionization chamber and the smallest scintillators. The time-resolved RapidArc dose profiles revealed volume-dependent discrepancies between scintillator and ionization chamber response

  14. Time-resolved spectroscopy using a chopper wheel as a fast shutter

    International Nuclear Information System (INIS)

    Wang, Shicong; Wendt, Amy E.; Boffard, John B.; Lin, Chun C.

    2015-01-01

    Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsed light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas

  15. Time-resolved photoluminescence study of CdSe/CdMnS/CdS core/multi-shell nanoplatelets

    International Nuclear Information System (INIS)

    Murphy, J. R.; Delikanli, S.; Demir, H. V.; Scrace, T.; Zhang, P.; Norden, T.; Petrou, A.; Thomay, T.; Cartwright, A. N.

    2016-01-01

    We used photoluminescence spectroscopy to resolve two emission features in CdSe/CdMnS/CdS and CdSe/CdS core/multi-shell nanoplatelet heterostructures. The photoluminescence from the magnetic sample has a positive circular polarization with a maximum centered at the position of the lower energy feature. The higher energy feature has a corresponding signature in the absorption spectrum; this is not the case for the low-energy feature. We have also studied the temporal evolution of these features using a pulsed-excitation/time-resolved photoluminescence technique to investigate their corresponding recombination channels. A model was used to analyze the temporal dynamics of the photoluminescence which yielded two distinct timescales associated with these recombination channels. The above results indicate that the low-energy feature is associated with recombination of electrons with holes localized at the core/shell interfaces; the high-energy feature, on the other hand, is excitonic in nature with the holes confined within the CdSe cores.

  16. Time-resolved photoluminescence study of CdSe/CdMnS/CdS core/multi-shell nanoplatelets

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J. R. [Department of Electrical Engineering, State University of New York, University at Buffalo, Buffalo, New York 14260 (United States); Department of Physics, State University of New York, University at Buffalo, Buffalo, New York 14260 (United States); Delikanli, S.; Demir, H. V., E-mail: volkan@bilkent.edu.tr [LUMINOUS Center of Excellence for Semiconductor Lighting and Displays, School of Electrical and Electronic Engineering, School of Physical and Materials Sciences, Nanyang Technological University, Singapore 639798 (Singapore); Department of Electrical and Electronics Engineering, Department of Physics, UNAM−Institute of Materials Science and Nanotechnology, Bilkent University, Ankara 06800 (Turkey); Scrace, T.; Zhang, P.; Norden, T.; Petrou, A., E-mail: petrou@buffalo.edu [Department of Physics, State University of New York, University at Buffalo, Buffalo, New York 14260 (United States); Thomay, T.; Cartwright, A. N. [Department of Electrical Engineering, State University of New York, University at Buffalo, Buffalo, New York 14260 (United States)

    2016-06-13

    We used photoluminescence spectroscopy to resolve two emission features in CdSe/CdMnS/CdS and CdSe/CdS core/multi-shell nanoplatelet heterostructures. The photoluminescence from the magnetic sample has a positive circular polarization with a maximum centered at the position of the lower energy feature. The higher energy feature has a corresponding signature in the absorption spectrum; this is not the case for the low-energy feature. We have also studied the temporal evolution of these features using a pulsed-excitation/time-resolved photoluminescence technique to investigate their corresponding recombination channels. A model was used to analyze the temporal dynamics of the photoluminescence which yielded two distinct timescales associated with these recombination channels. The above results indicate that the low-energy feature is associated with recombination of electrons with holes localized at the core/shell interfaces; the high-energy feature, on the other hand, is excitonic in nature with the holes confined within the CdSe cores.

  17. Production of High Quality Die Steels from Large ESR Slab Ingots

    Science.gov (United States)

    Geng, Xin; Jiang, Zhou-hua; Li, Hua-bing; Liu, Fu-bin; Li, Xing

    With the rapid development of manufacture industry in China, die steels are in great need of large slab ingot of high quality and large tonnage, such as P20, WSM718R and so on. Solidification structure and size of large slab ingots produced with conventional methods are not satisfied. However, large slab ingots manufactured by ESR process have a good solidification structure and enough section size. In the present research, the new slab ESR process was used to produce the die steels large slab ingots with the maximum size of 980×2000×3200mm. The compact and sound ingot can be manufactured by the slab ESR process. The ultra-heavy plates with the maximum thickness of 410 mm can be obtained after rolling the 49 tons ingots. Due to reducing the cogging and forging process, the ESR for large slab ingots process can increase greatly the yield and production efficiency, and evidently cut off product costs.

  18. Time-resolved x-ray diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.

    1981-01-01

    Techniques for time-resolved x-ray diagnostics will be reviewed with emphasis on systems utilizing x-ray diodes or scintillators. System design concerns for high-bandwidth (> 1 GHz) diagnostics will be emphasized. The limitations of a coaxial cable system and a technique for equalizing to improve bandwidth of such a system will be reviewed. Characteristics of new multi-GHz amplifiers will be presented. An example of a complete operational system on the Los Alamos Helios laser will be presented which has a bandwidth near 3 GHz over 38 m of coax. The system includes the cable, an amplifier, an oscilloscope, and a digital camera readout

  19. ESR dating of submarine hydrothermal activities using barite in sulfide deposition

    Science.gov (United States)

    Toyoda, S.; Fujiwara, T.; Ishibashi, J.; Isono, Y.; Uchida, A.; Takamasa, A.; Nakai, S.

    2012-12-01

    The temporal change of submarine hydrothermal activities has been an important issue in the aspect of the evolution of hydrothermal systems which is related with ore formation (Urabe, 1995) and biological systems sustained by the chemical species arising from hydrothermal activities (Macdonald et al., 1980). Determining the ages of the hydrothermal deposit will provide essential information on such studies. Dating methods using disequilibrium between radioisotopes such as U-Th method (e.g. You and Bickle, 1998), 226}Ra-{210Pb and 228}Ra-{228Th method (e.g. Noguchi et al., 2011) have been applied to date submarine hydrothermal deposits. ESR (electron spin resonance) dating method is commonly applied to fossil teeth, shells, and quartz of Quaternay period where the natural accumulated dose is obtained from the intensities of the ESR signals which are created by natural radiation. The natural dose is divided by the dose rate to the mineral/sample to deduce the age. Okumura et al., (2010) made the first practical application of ESR (electron spin resonance) dating technique to a sample of submarine hydrothermal barite (BaSO4) to obtain preliminary ages, where Kasuya et al. (1991) first pointed out that barite can be used for ESR dating. Knowing that ESR dating of barite is promising, in this paper, we will present how we have investigated each factor that contributes ESR dating of barite in submarine hydrothermal sulfide deposition. (1) The best ESR condition for measuring the SO3- signal in barite is with the microwave power of 1mW and modulation amplitude of 0.1mT. (2) As results of heating experiments, the signal was found to be stable for the dating age range of several thousands. (3) 226Ra replacing Ba in barite is the source of the radiation. The amount of radioactive elements in sulfide mineral surrounding barite is negligible. (4) The external radiation from the sea water is negligible even in the submarine hydrothermal area where the radiation level is much

  20. ESR/Alanine {gamma}-dosimetry in the 10-30 Gy range

    Energy Technology Data Exchange (ETDEWEB)

    Fainstein, C. E-mail: cfainstein@cab.cnea.gov.ar; Winkler, E.; Saravi, M

    2000-05-15

    We report Alanine Dosimeter preparation, procedures for using the ESR/Dosimetry method, and the resulting calibration curve for {gamma}-irradiation in the range from 10-30 Gy. We use calibration curve to measure the irradiation dose in {gamma}-irradiation of human blood, as required in Blood Transfusion Therapy. The ESR/Alanine results are compared against those obtained using the thermoluminescent dosimetry (TLD) method.

  1. Determination of isodose curves in Radiotherapy using an Alanine/ESR dosemeter

    International Nuclear Information System (INIS)

    Chen, F.; Baffa, O.; Graeff, C.F.O.

    1998-01-01

    It was studied the possible use of an Alanine/ESR dosemeter in the isodose curves mapping in normal treatments of Radiotherapy. It was manufactured a lot of 150 dosemeters with base in a mixture of D-L Alanine dust (80 %) and paraffin (20 %). Each dosemeter has 4.7 mm diameter and 12 mm length. A group of 100 dosemeters of the lot were arranged inside 50 holes of the slice 25 of the phantom Rando Man. The phantom irradiation was realized in two opposed projections (AP and PA) in Co-60 equipment. A group of 15 dosemeters was take of the same lot for obtaining the calibration curve in a 1-20 Gy range. After irradiation the signal of each dosemeter was measured in an ESR spectrometer operating in the X-band (∼ 9.5 GHz) and the wideness of Alanine ESR spectra central line was correlated with the radiation dose. The wideness dose calibration curve resulted linear with a correlation coefficient 0.9996. The isodose curves obtained show a profile enough similar at comparing with the theoretical curves. (Author)

  2. Preliminary study on ESR dating of Hexian-Man and its fauna

    International Nuclear Information System (INIS)

    Huang Peihua; Zheng Lizhen; Quan Yucai; Liang Renyou; Xu Yunhua; Fang Yingsan; Fang Dusheng

    1995-01-01

    ESR dating results for samples of synchronous animal tooth with the skull of Hexian-Man in the lower part of the second layer show that the age of Hexian-Man is about 300(299.80) ka, corresponding to the late stage of Peiking-Man (the HIII skull of Peking-Man). The ages of Hexian-Man's Fauna are 150-300 ka, corresponding to those of the 2nd-3rd-4th layers of Peking-Man's Cave

  3. Time-resolved spectral measurements above 80 A

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Ceglio, N.; Medecki, H.

    1983-01-01

    We have made time-resolved spectral measurements above 80 A from laser-produced plasmas. These are made using a transmission grating spectrograph whose primary components are a cylindrically-curved x-ray mirror for light collection, a transmission grating for spectral dispersions, and an x-ray streak camera for temporal resolution. A description of the instrument and an example of the data are given

  4. Time resolved fluorescence of cow and goat milk powder

    Science.gov (United States)

    Brandao, Mariana P.; de Carvalho dos Anjos, Virgílio; Bell., Maria José V.

    2017-01-01

    Milk powder is an international dairy commodity. Goat and cow milk powders are significant sources of nutrients and the investigation of the authenticity and classification of milk powder is particularly important. The use of time-resolved fluorescence techniques to distinguish chemical composition and structure modifications could assist develop a portable and non-destructive methodology to perform milk powder classification and determine composition. This study goal is to differentiate milk powder samples from cows and goats using fluorescence lifetimes. The samples were excited at 315 nm and the fluorescence intensity decay registered at 468 nm. We observed fluorescence lifetimes of 1.5 ± 0.3, 6.4 ± 0.4 and 18.7 ± 2.5 ns for goat milk powder; and 1.7 ± 0.3, 6.9 ± 0.2 and 29.9 ± 1.6 ns for cow's milk powder. We discriminate goat and cow powder milk by analysis of variance using Fisher's method. In addition, we employed quadratic discriminant analysis to differentiate the milk samples with accuracy of 100%. Our results suggest that time-resolved fluorescence can provide a new method to the analysis of powder milk and its composition.

  5. Development of soft x-ray time-resolved photoemission spectroscopy system with a two-dimensional angle-resolved time-of-flight analyzer at SPring-8 BL07LSU

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Manami; Yamamoto, Susumu; Nakamura, Fumitaka; Yukawa, Ryu; Fukushima, Akiko; Harasawa, Ayumi; Kakizaki, Akito; Matsuda, Iwao [Institute for Solid State Physics, University of Tokyo, 5-1-5 Kashiwanoha, Chiba 277-8581 (Japan); Kousa, Yuka; Kondoh, Hiroshi [Department of Chemistry, Keio University, Yokohama 223-8522 (Japan); Tanaka, Yoshihito [RIKEN/SPring-8 Center, 1-1-1, Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan)

    2012-02-15

    We have developed a soft x-ray time-resolved photoemission spectroscopy system using synchrotron radiation (SR) at SPring-8 BL07LSU and an ultrashort pulse laser system. Two-dimensional angle-resolved measurements were performed with a time-of-flight-type analyzer. The photoemission spectroscopy system is synchronized to light pulses of SR and laser using a time control unit. The performance of the instrument is demonstrated by mapping the band structure of a Si(111) crystal over the surface Brillouin zones and observing relaxation of the surface photo-voltage effect using the pump (laser) and probe (SR) method.

  6. μSR spectroscopy on free radicals: a complement to ESR spectroscopy

    International Nuclear Information System (INIS)

    Cox, S.F.J.; Symons, M.C.R.

    1986-12-01

    The paper on ''μSR spectroscopy on free radicals'' was presented to the conference on ''Muon spin, rotation, relaxation and resonance'' Uppsala, 1986. The spectroscopic techniques for both ESR and μSR are described, along with the interpretation of the spectra, hyperfine coupling constants and radical structure. A comparison of ESR and μSR data is carried out with respect: to 1) isotope effects in organic radicals, 2) isotope effects in solids, -the isotropic muonium defect centres, and 3) the muonium defect centres in semiconductors. Radical categories examined using ESR and μSR are discussed, including new species, formation mechanisms, and ionic species. (U.K.)

  7. A hybrid breath hold and continued respiration-triggered technique for time-resolved 3D MRI perfusion studies in lung cancer

    International Nuclear Information System (INIS)

    Hintze, C.; Stemmer, A.; Bock, M.

    2010-01-01

    Assessment of lung cancer perfusion is impaired by respiratory motion. Imaging times for contrast agent wash-out studies often exceed breath hold capabilities, and respiration triggering reduces temporal resolution. Temporally resolved volume acquisition of entire tumors is required to assess heterogeneity. Therefore, we developed and evaluated an MR measurement technique that exceeds a single breath hold, and provides a variable temporal resolution during acquisition while suspending breath-dependent motion. 20 patients with suspected lung cancer were subjected to perfusion studies using a spoiled 3D gradient echo sequence after bolus injection of 0.07 mmol/kg body weight of Gd-DTPA. 10 acquisitions in expiratory breath hold were followed by 50 navigator-triggered acquisitions under free breathing. Post-processing allowed for co-registration of the 3D data sets. An ROI-based visualization of the signal-time curves was performed. In all cases motion-suspended, time-resolved volume data sets (40 x 33 x 10 cm 3 , voxel size: 2.1 x 2.1 x 5.0 mm 3 ) were generated with a variable, initially high temporal resolution (2.25 sec) that was synchronized with the breath pattern and covered up to 8(1)/(2) min. In 7 / 20 cases a remaining offset could be reduced by rigid co-registration. The tumors showed fast wash-in, followed by rapid signal decay (8 / 20) or a plateau. The feasibility of a perfusion study with hybrid breath hold and navigator-triggered time-resolved 3D MRI which combines high initial temporal resolution during breath hold with a long wash-out period under free breathing was demonstrated. (orig.)

  8. Generation of pulsed far-infrared radiation and its application for far-infrared time-resolved spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Yasuhiro [Tohoku Univ., Sendai (Japan). Faculty of Engineering

    1996-07-01

    So-called time-resolved spectroscopy technique has been used from old time as the means for studying the dynamic optical property, light-induced reaction and so on of matters. As an example, there is the method called pump and probe, and here, the wavelength of this probe light is the problem. If the object energy region is limited to about 0.1 eV, fast time-resolved spectroscopy is feasible relatively easily. However, energy region is extended to low energy region, the light source which is available as the pulsed probe light having sufficient intensity is limited. In this paper, the attempt of time-resolved spectroscopy utilizing coherent radiation, which has ended in failure, and the laser pulse-induced far-infrared radiation which can be utilized as new far-infrared probe light are reported. The reason why far-infrared radiation is used is explained. The attempt of time-resolved spectroscopy using NaCl crystals is reported on the equipment, the method of measuring absorption spectra and the results. Laser pulse-induced far-infrared radiation and the method of generating it are described. The multi-channel detector for far-infrared radiation which was made for trial is shown. (K.I.)

  9. Time-resolved magnetic field effects in exciplex systems under X-irradiation

    International Nuclear Information System (INIS)

    Anishchik, S.V.; Lavrik, N.L.

    1988-01-01

    The presence of exciplex systems after X-irradiation of pyrene and N,N-diethylaniline in methanol as well as the influence of the applied magnetic field on exciplex fluorescence was registered using a time-resolving method. The experimental results confirmed the hypothesis on exciplex emergence in the system under study. (author)

  10. ESR as a method for the characterization of alluvial sediments

    International Nuclear Information System (INIS)

    Tissoux, H.; Voinchet, P.; Lacquement, F.; Despriée, J.

    2015-01-01

    The possibility of using the parameters involved in the ESR dating of optically bleached quartz grains in a purpose of source determination was checked. In that aim, samples previously taken in different sedimentary formations of the Middle Loire Basin (Central France) and dated by ESR have been observed. First discrimination was made using the thorium and potassium content in the sediments obtained by gamma spectrometry. The plot of these 119 data on the Th/K Schlumberger diagram clearly demonstrated that it was possible to discriminate the clays associations included in the sediment from which the dated quartz are extracted. Clay's nature could then be indicative of the geological nature of the substratum of rivers from their sources. Second discrimination was made using the ESR intensities calculated from Al, Ti–H and Ti–Li paramagnetic centres on 18 samples. It appears that the combination of the non-bleachable aluminum trap (DAT) saturation intensity and the Ti–H/Ti–Li ratio intensities make possible the discrimination of the two main sources of the sediment: Massif Central and Paris Basin. More deeply, The Ti/OBAT (Optically bleachable aluminum traps) intensities made possible the discrimination of quartz grains of different geological sources or with different geothermal history within the Massif Central group. - Highlights: • We used ESR and gamma spectrometry for source determination of alluvial quartz grains. • Th/K ratio distinguishes sediments from rivers flowing in various geological contexts. • Al, Ti–H and Ti–Li ESR centers discriminate quartz of different geological sources.

  11. Usefulness of time-resolved projection MRA on evaluation of hemodynamics in cerebral occlusive diseases

    International Nuclear Information System (INIS)

    Oka, Yoshihisa; Kusunoki, Katsusuke; Nochide, Ichiro; Igase, Keiji; Harada, Hironobu; Sadamoto, Kazuhiko; Nagasawa, Kiyoshi

    2001-01-01

    The usefulness for evaluation of cerebral hemodynamics using time-resolved projection MRA was studied in normal volunteers and patients of cerebrovascular diseases. Six normal volunteers and ten patients with cerebrovascular occlusive diseases including 6 of IC occlusion and 4 of post EC/IC bypass surgery underwent time-resolved projection MRA on a 1.5 T clinical MRI system. Projection angiograms are acquired with 2D-fast SPGR sequence with a time resolution of approximately one image per second, 40 images being acquired consecutively before and after bolus injection Gd-DTPA. And all images were calculated by complex subtraction from the background mask in a work station. In normal volunteers, the quality of images of time-resolved projection MRA was satisfactory. The arteries from internal carotid artery through M2 segment of middle cerebral artery and all major venous systems were well portrayed. In 4 cases of IC occlusion who were assessed the collateral flow through the anterior communicating artery and posterior communicating artery, there were delayed to demonstrate the ipsilateral MCA. However, in 2 cases of IC occlusion that were assessed the collateral flow through leptomeningeal anastomosis, ipsilateral MCA and collateral circulation were not demonstrated. In all patients of post EC/IC bypass surgery, the patency of EC/IC bypass could be evaluated as properly with time-resolved projection MRA as 3D-TOF MRA. Although the temporal and spatial resolutions are insufficient, time-resolved projection MRA was power-full non-invasive method to evaluate the cerebral hemodynamics vis the basal communicating arteries in IC occlusion and identify the patency of EC/IC bypass. (author)

  12. Assembly and application of an instrument for attosecond-time-resolved ionization chronoscopy

    International Nuclear Information System (INIS)

    Uphues, T.

    2006-11-01

    In the framework of this thesis a new setup for attosecond time-resolved measurements has been built and observations of ionization dynamics in rare gas atoms have been made. This new technique is entitled Ionization Chronoscopy and gives further evidence that time-resolved experiments in the attosecond regime will become a powerful tool for investigations in atomic physics. (orig.)

  13. ESR studies on the effects of ionizing radiation in biological media

    International Nuclear Information System (INIS)

    Stockhausen, K.

    1976-01-01

    The various effects of molecular oxygen on the radiosensitivity of bacteria is closely connected with the development of peroxyradicals during radiation exposure and their effects. Irradiated 'molecular mixtures' consisting of sephadex and penicillamine show the phenomenon of energy transfer. This might be a fundamental aspect of the damage to biomolecules on the one hand and of the molecular radiation protection on the other. Very closely connected with this phenomenon is the 'repair' of damaged cell modules by radioprotective substances, such as amino acids containing sulphur. Damaged heads of the spermatozoons of herrings are obviously 'repaired' during storage of several days' duration at room temperature if a few percent of the immunizing substance mercaptoethylamine are added to them during irradiation. ESR-examinations of DNA and its components make the mutagenic effect of ionising radiation plausible. They give information about the points in these macromolecules in which radicals are localized. Quantitative determinations of the yield of radicals in each component of the DNA show that there are significant differences in the radiosensitivity of the different DNA-modules and that energy transfer processes can take place within the macromolecule. Longlived radicals in certain tissues of the living organism, such as bones, fingernails, or teeth, can be very useful to develop methods of dosimetry after radiation accidents and of radiotherapy with the help of the help of the ESR-techniques. (orig.) [de

  14. Status report of the ESR/alanine project of the IAEA Dosimetry Laboratory

    International Nuclear Information System (INIS)

    Girzikowsky, R.

    1990-01-01

    beams up to 20 MeV, no fading effects when stored at room temperature and ∼ 50% relative humidity, no transport restrictions, and repeated read-out and reusability up to a total accumulated dose ≤ saturation dose (= 500 kGy) due to the non-destructive character of ESR spectroscopic read-out technique. These properties of alanine powder are not influenced by adding binder material like parafine, polymer or plastic to form solid dosimeters of different sizes and shapes (e.g., rods, pellets, pills, discs or thin films). This dosimeter system is capable of an overall uncertainty of ≤ 3,5%, which makes it superior to other high-dose dosimeter systems. Further investigations will be undertaken in order to cover lower dose ranges down to a few cGy for application on clinical dosimetry. This development is a future task of the Agency's Dosimetry Laboratory to obtain a competing system to the established TLD system used for the postal dose intercomparison service. For the time being the establishment of the ESR/alanine system for high-dose dosimetry is carried out and will be completed by the end of this year. Consequently, the IDAS programme will be executed in the future by the Dosimetry Laboratory

  15. Time-resolved measurements with intense ultrashort laser pulses: a 'molecular movie' in real time

    International Nuclear Information System (INIS)

    Rudenko, A; Ergler, Th; Feuerstein, B; Zrost, K; Schroeter, C D; Moshammer, R; Ullrich, J

    2007-01-01

    We report on the high-resolution multidimensional real-time mapping of H 2 + and D 2 + nuclear wave packets performed employing time-resolved three-dimensional Coulomb explosion imaging with intense laser pulses. Exploiting a combination of a 'reaction microscope' spectrometer and a pump-probe setup with two intense 6-7 fs laser pulses, we simultaneously visualize both vibrational and rotational motion of the molecule, and obtain a sequence of snapshots of the squared ro-vibrational wave function with time-step resolution of ∼ 0.3 fs, allowing us to reconstruct a real-time movie of the ultrafast molecular motion. We observe fast dephasing, or 'collapse' of the vibrational wave packet and its subsequent revival, as well as signatures of rotational excitation. For D 2 + we resolve also the fractional revivals resulting from the interference between the counter-propagating parts of the wave packet

  16. The TimBel synchronization board for time resolved experiments at synchrotron SOLEIL

    International Nuclear Information System (INIS)

    Ricaud, J.P.; Betinelli-Deck, P.; Bisou, J.; Elattaoui, X.; Laulhe, C.; Monteiro, P.; Nadolski, L.S.; Renaud, G.; Ravy, S.; Silly, M.; Sirotti, F.

    2012-01-01

    Time resolved experiments are one of the major services that synchrotrons can provide to scientists. The short, high frequency and regular flashes of synchrotron light are a fantastic tool to study the evolution of phenomena over time. To carry out time resolved experiments, beamlines need to synchronize their devices with these flashes of light with a jitter shorter than the pulse duration. For that purpose, Synchrotron SOLEIL has developed the TimBeL (Timing Beamlines) board fully interfaced to TANGO framework. The TimBeL system is a compact PCI board. It is made of a mother with one daughter board. All functions are performed inside a FPGA (Field Programmable Gate Array) implemented on the mother board. A PLX Technology chip is used to communicate with the compact PCI crate. To enable experiments to remain always synchronous with the same bunch of electrons, the storage ring clock (CLK-SR) and the radio frequency clock (CLK-RF) are provided by the machine to beamlines. These clocks are used inside the FPGA as main clocks for state machines. Because the jitter is too large on the FPGA outputs, a daughter board with a jitter cleaner has been added to the system. This board also provides delay lines for compensating time offsets by 10 ps steps. This paper presents the main features required by time resolved experiments and how we achieved our goals with the TimBeL board

  17. ESR/alanine dosimetry: Study of the kinetics of free radical formation. Evaluation of its contribution to the evolution of the signal after irradiation

    International Nuclear Information System (INIS)

    Dolo, J.M.; Feaugas, V.; Hourdin, L.

    1999-01-01

    CH 3 C HCOOH is commonly accepted as the free radical responsible for the ESR signal detected in alanine after irradiation. The aim of this study is to find out the number of transient species leading to this radical and their kinetics of reaction. To do so, we follow the evolution of the ESR/alanine spectrum shape and correlate the response estimated from the central peak height to the absorbed dose. We use the theory of transformation systems. The first step is to make hypothesis on the number of equivalence classes and their content. From these hypotheses, we model the kinetics of free radical concentrations and check their fitting with experiment. We present comments on these different models, and their consequences on the evolution of the ESR signal on the first days after irradiation. The two successive reaction mechanisms (creation of free radicals and recombination reaction) are compared with the results obtained from a multiparametric study (experimental design) of combined effects (temperature and humidity before and after irradiation) which influence the reaction kinetics. (author)

  18. Denoising time-resolved microscopy image sequences with singular value thresholding

    Energy Technology Data Exchange (ETDEWEB)

    Furnival, Tom, E-mail: tjof2@cam.ac.uk; Leary, Rowan K., E-mail: rkl26@cam.ac.uk; Midgley, Paul A., E-mail: pam33@cam.ac.uk

    2017-07-15

    Time-resolved imaging in microscopy is important for the direct observation of a range of dynamic processes in both the physical and life sciences. However, the image sequences are often corrupted by noise, either as a result of high frame rates or a need to limit the radiation dose received by the sample. Here we exploit both spatial and temporal correlations using low-rank matrix recovery methods to denoise microscopy image sequences. We also make use of an unbiased risk estimator to address the issue of how much thresholding to apply in a robust and automated manner. The performance of the technique is demonstrated using simulated image sequences, as well as experimental scanning transmission electron microscopy data, where surface adatom motion and nanoparticle structural dynamics are recovered at rates of up to 32 frames per second. - Highlights: • Correlations in space and time are harnessed to denoise microscopy image sequences. • A robust estimator provides automated selection of the denoising parameter. • Motion tracking and automated noise estimation provides a versatile algorithm. • Application to time-resolved STEM enables study of atomic and nanoparticle dynamics.

  19. Time resolved x-ray photography of a dense plasma focus

    International Nuclear Information System (INIS)

    Burnett, J.C.; Meyer, J.; Rankin, G.

    1977-01-01

    The temporal development of the hot plasma in a dense plasma focus is studied by x-ray streak photography of approximately 2 ns resolution time. It is shown that initially a uniform x-ray emitting pinch plasma is formed which subsequently cools down until x-ray emission stops after approximately 50 ns. At a time of around 100 ns after initial x-ray emission coinciding with the break-up time of the pinch a second burst of x-rays is observed coming from small localized regions. The observations are compared with results obtained from time-resolved shadow and schlieren photography of a similar dense focus discharge. (author)

  20. Time-resolved FTIR [Fourier transform infrared] emission studies of laser photofragmentation and chain reactions

    International Nuclear Information System (INIS)

    Leone, S.R.

    1990-01-01

    Recent progress is described resulting from the past three years of DOE support for studies of combustion-related photofragmentation dynamics, energy transfer, and reaction processes using a time-resolved Fourier transform infrared (FTIR) emission technique. The FTIR is coupled to a high repetition rate excimer laser which produces radicals by photolysis to obtain novel, high resolution measurements on vibrational and rotational state dynamics. The results are important for the study of numerous radical species relevant to combustion processes. The method has been applied to the detailed study of photofragmentation dynamics in systems such as acetylene, which produces C 2 H; chlorofluoroethylene to study the HF product channel; vinyl chloride and dichloroethylene, which produce HCl; acetone, which produces CO and CH 3 ; and ammonia, which produces NH 2 . In addition, we have recently demonstrated use of the FTIR technique for preliminary studies of energy transfer events under near single collision conditions, radical-radical reactions, and laser-initiated chain reaction processes

  1. The role of IL6 and ESR1 gene polymorphisms as immunological factors of pregnancy maintenance

    Directory of Open Access Journals (Sweden)

    Kucherenko A. M.

    2013-09-01

    Full Text Available Aim. The study is aimed at the evaluation of the association of IL6 gene -174G/C polymorphism and ESR1 gene -397C/T polymorphism with recurrent pregnancy loss (RPL pathogenesis and at the investigation of the ESR1 gene -397C/T variant regulatory significance for the IL6 gene function. Methods. A case group of 75 women with RPL history and a control group of 106 unrelated healthy women, who have given birth to at least one child conceived in natural way, were genotyped by a PCR based restriction fragment length polymorphism assay. Results. There was no significant difference in IL6 -174G/C or ESR1 -397C/T genotype and allele frequencies between the case and control groups. Combined genotype distribution analysis showed significantly (p < 0.05 lower frequency of individuals homozygous for both IL6 -174G and ESR1 -397C alleles in case group (0.026 comparing to control (0.094. Conclusions. Genotype comprising IL6 -174G and ESR1 -397C alleles in homozygous state may be considered as a genetic marker of successful pregnancy maintenance during gestation early stages.

  2. A synchrotron radiation camera and data acquisition system for time resolved x-ray scattering studies

    International Nuclear Information System (INIS)

    Bordas, J.; Koch, M.H.J.; Clout, P.N.; Dorrington, E.; Boulin, C.; Gabriel, A.

    1980-01-01

    Until recently, time resolved measurements of x-ray scattering patterns have not been feasible because laboratory x-ray sources were too weak and detectors unavailable. Recent developments in both these fields have changed the situation, and it is now possible to follow changes in x-ray scattering patterns with a time resolution of a few ms. The apparatus used to achieve this is described and some examples from recent biological experiments are given. (author)

  3. Recent progress in application of JAERI alanine/ESR dosimetry system

    International Nuclear Information System (INIS)

    Kojima, T.

    1995-01-01

    Feasibility studies of application of JAERI alanine/ESR dosimetry system were performed on radiotherapy level dosimetry, low dose-rate dosimetry for residual life estimation of cable insulators used in nuclear power facilities, and dose monitoring for electron processing. (author)

  4. Time- and Site-Resolved Dynamics in a Topological Circuit

    Directory of Open Access Journals (Sweden)

    Jia Ningyuan

    2015-06-01

    Full Text Available From studies of exotic quantum many-body phenomena to applications in spintronics and quantum information processing, topological materials are poised to revolutionize the condensed-matter frontier and the landscape of modern materials science. Accordingly, there is a broad effort to realize topologically nontrivial electronic and photonic materials for fundamental science as well as practical applications. In this work, we demonstrate the first simultaneous site- and time-resolved measurements of a time-reversal-invariant topological band structure, which we realize in a radio-frequency photonic circuit. We control band-structure topology via local permutation of a traveling-wave capacitor-inductor network, increasing robustness by going beyond the tight-binding limit. We observe a gapped density of states consistent with a modified Hofstadter spectrum at a flux per plaquette of ϕ=π/2. In situ probes of the band gaps reveal spatially localized bulk states and delocalized edge states. Time-resolved measurements reveal dynamical separation of localized edge excitations into spin-polarized currents. The radio-frequency circuit paradigm is naturally compatible with nonlocal coupling schemes, allowing us to implement a Möbius strip topology inaccessible in conventional systems. This room-temperature experiment illuminates the origins of topology in band structure, and when combined with circuit quantum electrodynamics techniques, it provides a direct path to topologically ordered quantum matter.

  5. Time-resolved suprathermal x-rays

    International Nuclear Information System (INIS)

    Lee, P.H.Y.; Rosen, M.D.

    1978-01-01

    Temporally resolved x-ray spectra in the range of 1 to 20 keV have been obtained from gold disk targets irradiated by 1.06 μm laser pulses from the Argus facility. The x-ray streak camera used for the measurement has been calibrated for streak speed and dynamic range by using an air-gap Fabry-Perot etalon, and the instrument response has been calibrated using a multi-range monoenergetic x-ray source. The experimental results indicate that we are able to observe the ''hot'' x-ray temperature evolve in time and that the experimentally observed values can be qualitatively predicted by LASNEX code computations when the inhibited transport model is used

  6. ESR spectra studies on polyterafluoroethyene films irradiated by radio frequency plasmas

    International Nuclear Information System (INIS)

    Ma Yuguang; Yang Meiling; Shen Jiacong; Lin Dehou

    1991-01-01

    The PTFE (polytetrafluoroethylene) films irradiated by Ar plasma were studied by using the method of ESR spectrometer. The peroxide free radicals were found on the surface of PTFE after plasma irradiation, which existed in the layer of some thickness of the surface. These free radicals were quite stable at room temperature. But when density of peroxide free radicals on the PTFE surface was big enough, termination reaction between the peroxide free radicals bound happen and endoperoxides were formed on the PTFE surface. Also the density of peroxide free radical decreased with increasing temperature and underwent a sudden change with temperature reaching 399 K- the glass transition temperature PTFE. The peroxide free radicals can be caught by free radical catcher PBN to form a stable free radical, also can react with MMA to form grafting layer

  7. Electron Spin Resonance (ESR) and Thermoluminescence (TL) studies of stalagmitic floors of the Caune de de L'Arago at Tautavel (France)

    International Nuclear Information System (INIS)

    Poupeau, G.; Teles, M.M.; Rossi, A.; Zuleta, E.; Yokoyama, Y.

    1984-01-01

    The geological radiation dose to the stalagmites of various stratigraphic levels of the Caune de L'Arago at Tautavel has been measured by Thermoluminescence (TL) and Electron Spin Resonance (ESR). In all samples the TL natural spectrum a well developped 280 0 C peak and a subordinate 350 0 C peak, while the ESR line spectrum may present the h 1 , h 2 and h 3 radiative lines of Yokoyama et al.) or only h 2 . All TL peaks and ESR lines do increase with the laboratory applied radiation (β or γ) doses. The activated h 2 line is visibly unstable in laboratory conditions as well as apparently the h 3 line in one sample. Within the experimental precision, the geological doses determined from the 280C peak and h 3 line on one band and the 350 0 C peak and h 1 line (after thermal treatment of the later, see Yokoyama et al. on the other hand are identical. When the 280C natural peak is visibly affected by natural fading as shown by the plateau test, so is h 3 , and the geological doses of the 280 0 C-h 3 peaks are lowered by the same factor as compared to those of the 350 0 C-h 1 peaks. Annealing experiments show that the relationships between the TL and ESR peaks may be difficult to analyse in some samples due to the possible occurence of non radiative components in some ESR lines. Such components appear clearly at temperatures above approx. 180-200 0 C and might possibly be present below. This may have important implications for the selection of samples to be dated by ESR. (Author) [pt

  8. Time-resolved measurements of supersonic fuel sprays using synchrotron X-rays.

    Science.gov (United States)

    Powell, C F; Yue, Y; Poola, R; Wang, J

    2000-11-01

    A time-resolved radiographic technique has been developed for probing the fuel distribution close to the nozzle of a high-pressure single-hole diesel injector. The measurement was made using X-ray absorption of monochromatic synchrotron-generated radiation, allowing quantitative determination of the fuel distribution in this optically impenetrable region with a time resolution of better than 1 micros. These quantitative measurements constitute the most detailed near-nozzle study of a fuel spray to date.

  9. An ESR protocol based on relaxation phenomena of irradiated Japanese pepper

    Science.gov (United States)

    Ukai, Mitsuko; Nakamura, Hideo; Shimoyama, Yuhei

    2006-03-01

    We found various free radicals in a commercially available pepper in Japan before and after irradiation using electron spin resonance (ESR) spectroscopy. The typical ESR spectrum of the pepper consists of a sextet centered at g = 2.0, a singlet at the same g-value and a singlet at g = 4.0. Upon gamma ray irradiation, a new pair of signals appeared in the pepper. The progressive saturation behavior (PSB) at various microwave power levels indicated quite different relaxation behaviors of those radicals. Namely, the peak intensity of the organic free radical component decreases in a monotonic fashion, whereas the Mn 2+ and Fe 3+ ESR signals substantially keep constant. This reflects the evidence of three independent radicals in the pepper before irradiation. The PSB of the pair peaks as induced by irradiation possessed quite different PSB from that of the free radical located at g = 2.0. We proposed a new protocol for the ESR detection of irradiated foods by the PSB method at different microwave power levels. This would call for a major modification of the CEN protocol in European Union.

  10. Time-resolved High Spectral Resolution Observation of 2MASSW J0746425+200032AB

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ji; Mawet, Dimitri [Department of Astronomy, California Institute of Technology, MC 249-17, 1200 E. California Boulevard, Pasadena, CA 91106 (United States); Prato, Lisa, E-mail: ji.wang@caltech.edu [Lowell Observatory, 1400 West Mars Hill Road, Flagstaff, AZ 86001 (United States)

    2017-03-20

    Many brown dwarfs (BDs) exhibit photometric variability at levels from tenths to tens of percents. The photometric variability is related to magnetic activity or patchy cloud coverage, characteristic of BDs near the L–T transition. Time-resolved spectral monitoring of BDs provides diagnostics of cloud distribution and condensate properties. However, current time-resolved spectral studies of BDs are limited to low spectral resolution ( R ∼ 100) with the exception of the study of Luhman 16 AB at a resolution of 100,000 using the VLT+CRIRES. This work yielded the first map of BD surface inhomogeneity, highlighting the importance and unique contribution of high spectral resolution observations. Here, we report on the time-resolved high spectral resolution observations of a nearby BD binary, 2MASSW J0746425+200032AB. We find no coherent spectral variability that is modulated with rotation. Based on simulations, we conclude that the coverage of a single spot on 2MASSW J0746425+200032AB is smaller than 1% or 6.25% if spot contrast is 50% or 80% of its surrounding flux, respectively. Future high spectral resolution observations aided by adaptive optics systems can put tighter constraints on the spectral variability of 2MASSW J0746425+200032AB and other nearby BDs.

  11. Morphological Analysis of the Axonal Projections of EGFP-Labeled Esr1-Expressing Neurons in Transgenic Female Medaka.

    Science.gov (United States)

    Zempo, Buntaro; Karigo, Tomomi; Kanda, Shinji; Akazome, Yasuhisa; Oka, Yoshitaka

    2018-02-01

    Some hypothalamic neurons expressing estrogen receptor α (Esr1) are thought to transmit a gonadal estrogen feedback signal to gonadotropin-releasing hormone 1 (GnRH1) neurons, which is the final common pathway for feedback regulation of reproductive functions. Moreover, estrogen-sensitive neurons are suggested to control sexual behaviors in coordination with reproduction. In mammals, hypothalamic estrogen-sensitive neurons release the peptide kisspeptin and regulate GnRH1 neurons. However, a growing body of evidence in nonmammalian species casts doubt on the regulation of GnRH1 neurons by kisspeptin neurons. As a step toward understanding how estrogen regulates neuronal circuits for reproduction and sex behavior in vertebrates in general, we generated a transgenic (Tg) medaka that expresses enhanced green fluorescent protein (EGFP) specifically in esr1-expressing neurons (esr1 neurons) and analyzed their axonal projections. We found that esr1 neurons in the preoptic area (POA) project to the gnrh1 neurons. We also demonstrated by transcriptome and histological analyses that these esr1 neurons are glutamatergic or γ-aminobutyric acidergic (GABAergic) but not kisspeptinergic. We therefore suggest that glutamatergic and GABAergic esr1 neurons in the POA regulate gnrh1 neurons. This hypothesis is consistent with previous studies in mice that found that glutamatergic and GABAergic transmission is critical for estrogen-dependent changes in GnRH1 neuron firing. Thus, we propose that this neuronal circuit may provide an evolutionarily conserved mechanism for regulation of reproduction. In addition, we showed that telencephalic esr1 neurons project to medulla, which may control sexual behavior. Moreover, we found that some POA-esr1 neurons coexpress progesterone receptors. These neurons may form the neuronal circuits that regulate reproduction and sex behavior in response to the serum estrogen/progesterone. Copyright © 2018 Endocrine Society.

  12. Advances in high-order harmonic generation sources for time-resolved investigations

    Energy Technology Data Exchange (ETDEWEB)

    Reduzzi, Maurizio [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Institute of Photonics and Nanotechnologies, CNR-IFN, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Carpeggiani, Paolo [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Kühn, Sergei [ELI-ALPS, ELI-Hu Kft., Dugonics ter 13, H-6720 Szeged (Hungary); Calegari, Francesca [Institute of Photonics and Nanotechnologies, CNR-IFN, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Nisoli, Mauro; Stagira, Salvatore [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Institute of Photonics and Nanotechnologies, CNR-IFN, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Vozzi, Caterina [Institute of Photonics and Nanotechnologies, CNR-IFN, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Dombi, Peter [ELI-ALPS, ELI-Hu Kft., Dugonics ter 13, H-6720 Szeged (Hungary); Wigner Research Center for Physics, 1121 Budapest (Hungary); Kahaly, Subhendu [ELI-ALPS, ELI-Hu Kft., Dugonics ter 13, H-6720 Szeged (Hungary); Tzallas, Paris; Charalambidis, Dimitris [ELI-ALPS, ELI-Hu Kft., Dugonics ter 13, H-6720 Szeged (Hungary); Foundation for Research and Technology – Hellas, Institute of Electronic Structure and Lasers, P.O. Box 1527, GR-711 10 Heraklion, Crete (Greece); Varju, Katalin [ELI-ALPS, ELI-Hu Kft., Dugonics ter 13, H-6720 Szeged (Hungary); Department of Optics and Quantum Electronics, University of Szeged, Dóm tér 9, 6720 Szeged (Hungary); Osvay, Karoly [ELI-ALPS, ELI-Hu Kft., Dugonics ter 13, H-6720 Szeged (Hungary); and others

    2015-10-15

    We review the main research directions ongoing in the development of extreme ultraviolet sources based on high-harmonic generation for the synthesization and application of trains and isolated attosecond pulses to time-resolved spectroscopy. A few experimental and theoretical works will be discussed in connection to well-established attosecond techniques. In this context, we present the unique possibilities offered for time-resolved investigations on the attosecond timescale by the new Extreme Light Infrastructure Attosecond Light Pulse Source, which is currently under construction.

  13. Advances in high-order harmonic generation sources for time-resolved investigations

    International Nuclear Information System (INIS)

    Reduzzi, Maurizio; Carpeggiani, Paolo; Kühn, Sergei; Calegari, Francesca; Nisoli, Mauro; Stagira, Salvatore; Vozzi, Caterina; Dombi, Peter; Kahaly, Subhendu; Tzallas, Paris; Charalambidis, Dimitris; Varju, Katalin; Osvay, Karoly

    2015-01-01

    We review the main research directions ongoing in the development of extreme ultraviolet sources based on high-harmonic generation for the synthesization and application of trains and isolated attosecond pulses to time-resolved spectroscopy. A few experimental and theoretical works will be discussed in connection to well-established attosecond techniques. In this context, we present the unique possibilities offered for time-resolved investigations on the attosecond timescale by the new Extreme Light Infrastructure Attosecond Light Pulse Source, which is currently under construction.

  14. The time resolved SBS and SRS research in heavy water and its application in CARS

    Science.gov (United States)

    Liu, Jinbo; Gai, Baodong; Yuan, Hong; Sun, Jianfeng; Zhou, Xin; Liu, Di; Xia, Xusheng; Wang, Pengyuan; Hu, Shu; Chen, Ying; Guo, Jingwei; Jin, Yuqi; Sang, Fengting

    2018-05-01

    We present the time-resolved character of stimulated Brillouin scattering (SBS) and backward stimulated Raman scattering (BSRS) in heavy water and its application in Coherent Anti-Stokes Raman Scattering (CARS) technique. A nanosecond laser from a frequency-doubled Nd: YAG laser is introduced into a heavy water cell, to generate SBS and BSRS beams. The SBS and BSRS beams are collinear, and their time resolved characters are studied by a streak camera, experiment show that they are ideal source for an alignment-free CARS system, and the time resolved property of SBS and BSRS beams could affect the CARS efficiency significantly. By inserting a Dye cuvette to the collinear beams, the time-overlapping of SBS and BSRS could be improved, and finally the CARS efficiency is increased, even though the SBS energy is decreased. Possible methods to improve the efficiency of this CARS system are discussed too.

  15. Femtosecond Time-Resolved Resonance-Enhanced CARS of Gaseous Iodine at Room Temperature

    International Nuclear Information System (INIS)

    He Ping; Fan Rong-Wei; Xia Yuan-Qin; Yu Xin; Chen De-Ying; Yao Yong

    2011-01-01

    Time-resolved resonance-enhanced coherent anti-Stokes Raman scattering (CARS) is applied to investigate molecular dynamics in gaseous iodine. 40 fs laser pulses are applied to create and monitor the high vibrational states of iodine at room temperature (corresponding to a vapor pressure as low as about 35 Pa) by femtosecond time-resolved CARS. Depending on the time delay between the probe pulse and the pump/Stokes pulse pairs, the high vibrational states both on the electronically ground states and the excited states can be detected as oscillations in the CARS transient signal. It is proved that the femtosecond time-resolved CARS technique is a promising candidate for investigating the molecular dynamics of a low concentration system and can be applied to environmental and atmospheric monitoring measurements. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  16. Reflectivity quenching of ESR multilayer polymer film reflector in optically bonded scintillator arrays

    Science.gov (United States)

    Loignon-Houle, Francis; Pepin, Catherine M.; Charlebois, Serge A.; Lecomte, Roger

    2017-04-01

    The 3M-ESR multilayer polymer film is a widely used reflector in scintillation detector arrays. As specified in the datasheet and confirmed experimentally by measurements in air, it is highly reflective (> 98 %) over the entire visible spectrum (400-1000 nm) for all angles of incidence. Despite these outstanding characteristics, it was previously found that light crosstalk between pixels in a bonded LYSO scintillator array with ESR reflector can be as high as ∼30-35%. This unexplained light crosstalk motivated further investigation of ESR optical performance. Analytical simulation of a multilayer structure emulating the ESR reflector showed that the film becomes highly transparent to incident light at large angles when surrounded on both sides by materials of refractive index higher than air. Monte Carlo simulations indicate that a considerable fraction (∼25-35%) of scintillation photons are incident at these leaking angles in high aspect ratio LYSO scintillation crystals. The film transparency was investigated experimentally by measuring the scintillation light transmission through the ESR film sandwiched between a scintillation crystal and a photodetector with or without layers of silicone grease. Strong light leakage, up to nearly 30%, was measured through the reflector when coated on both sides with silicone, thus elucidating the major cause of light crosstalk in bonded arrays. The reflector transparency was confirmed experimentally for angles of incidence larger than 60 ° using a custom designed setup allowing illumination of the bonded ESR film at selected grazing angles. The unsuspected ESR film transparency can be beneficial for detector arrays exploiting light sharing schemes, but it is highly detrimental for scintillator arrays designed for individual pixel readout.

  17. ESR-dating of subfossil mollusc shells: the problem of absorbed paleodose fading

    International Nuclear Information System (INIS)

    Molod'kov, A.

    1988-01-01

    Detailed investigation of paleodosimetric prperties of subfossil mollusc shells has been carried out with respect to their dating by ESR-spectroscopy. Attention has been paid to the connection between the absorbed paleodose value and factors on the upper dating limit. Energetic parameters of the CO 3 3- centres have been determined in the calcareous shell skeleton serving as a paleodetector: E=1.515 eV, ν 0 =8x10 13 s -1 , τ=1.14x10 6 years at 5 deg C. Mathematical models have been elaborated for the accumulation of paleodose in natural conditions. New paleodosimetric equations proposed for calculating the age of shells and some minerals may be applied both to ESR- and thermoluminescence-dating. The proposed method enables one to date the shells within the time span of nx10 2 -nx10 6 years

  18. Recognition of malignant processes with neural nets from ESR spectra of serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, P. [Inst. of Medical Physics and Biophysics, Univ. Leipzig (Germany); Gurachevsky, A.; Muravsky, V.; Schnurr, K.; Seibt, G. [Medinnovation GmbH, Wildau (Germany); Matthes, G. [Inst. of Transfusion Medicine, Univ. Hospital Leipzig (Germany)

    2005-07-01

    Cancer diseases are the focus of intense research due to their frequent occurrence. It is known from the literature that serum proteins are changed in the case of malignant processes. Changes of albumin conformation, transport efficiency, and binding characteristics can be determined by electron spin resonance spectroscopy (ESR). The present study analysed the binding/dissociation function of albumin with an ESR method using 16-doxyl stearate spin probe as reporter molecule and ethanol as modifier of hydrophobic interactions. Native and frozen plasma of healthy donors (608 samples), patients with malignant diseases (423 samples), and patients with benign conditions (221 samples) were analysed. The global specificity was 91% and the sensitivity 96%. In look-back samples of 27 donors, a malignant process could be detected up to 30 months before clinical diagnosis. To recognise different entities of malignant diseases from the ESR spectra, Artificial neural networks were implemented. For 48 female donors with breast cancer, the recognition specificity was 85%. Other carcinoma entities (22 colon, 18 prostate, 12 stomach) were recognised with specificities between 75% and 84%. Should these specificity values be reproduced in larger studies, the described method could be used as a new specific tumour marker for the early detection of malignant processes. Since transmission of cancer via blood transfusion cannot be excluded as yet, the described ESR method could also be used as a quality test for plasma products. (orig.)

  19. Recognition of malignant processes with neural nets from ESR spectra of serum albumin

    International Nuclear Information System (INIS)

    Seidel, P.; Gurachevsky, A.; Muravsky, V.; Schnurr, K.; Seibt, G.; Matthes, G.

    2005-01-01

    Cancer diseases are the focus of intense research due to their frequent occurrence. It is known from the literature that serum proteins are changed in the case of malignant processes. Changes of albumin conformation, transport efficiency, and binding characteristics can be determined by electron spin resonance spectroscopy (ESR). The present study analysed the binding/dissociation function of albumin with an ESR method using 16-doxyl stearate spin probe as reporter molecule and ethanol as modifier of hydrophobic interactions. Native and frozen plasma of healthy donors (608 samples), patients with malignant diseases (423 samples), and patients with benign conditions (221 samples) were analysed. The global specificity was 91% and the sensitivity 96%. In look-back samples of 27 donors, a malignant process could be detected up to 30 months before clinical diagnosis. To recognise different entities of malignant diseases from the ESR spectra, Artificial neural networks were implemented. For 48 female donors with breast cancer, the recognition specificity was 85%. Other carcinoma entities (22 colon, 18 prostate, 12 stomach) were recognised with specificities between 75% and 84%. Should these specificity values be reproduced in larger studies, the described method could be used as a new specific tumour marker for the early detection of malignant processes. Since transmission of cancer via blood transfusion cannot be excluded as yet, the described ESR method could also be used as a quality test for plasma products. (orig.)

  20. Time resolved spectroscopy of GRB 030501 using INTEGRAL

    DEFF Research Database (Denmark)

    Beckmann, V.; Borkowski, J.; Courvoisier, T.J.L.

    2003-01-01

    The gamma-ray instruments on-board INTEGRAL offer an unique opportunity to perform time resolved analysis on GRBs. The imager IBIS allows accurate positioning of GRBs and broad band spectral analysis, while SPI provides high resolution spectroscopy. GRB 030501 was discovered by the INTEGRAL Burst...... the Ulysses and RHESSI experiments....

  1. Time-resolved wave profile measurements in copper to Megabar pressures

    Energy Technology Data Exchange (ETDEWEB)

    Chhabildas, L C; Asay, J R

    1981-01-01

    Many time-resolved techniques have been developed which have greatly aided in the understanding of dynamic material behavior such as the high pressure-dynamic strength of materials. In the paper, time-resolved measurements of copper (at shock-induced high pressures and temperatures) are used to illustrate the capability of using such techniques to investigate high pressure strength. Continuous shock loading and release wave profiles have been made in copper to 93 GPa using velocity interferometric techniques. Fine structure in the release wave profiles from the shocked state indicates an increase in shear strength of copper to 1.5 GPa at 93 GPa from its ambient value of 0.08 GPa.

  2. Direct observation of ultrafast atomic motion using time-resolved X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Shymanovich, U.

    2007-11-13

    This thesis is dedicated to the study of the atomic motion in laser irradiated solids on a picosecond to subpicosecond time-scale using the time-resolved X-ray diffraction technique. In the second chapter, the laser system, the laser-plasma based X-ray source and the experimental setup for optical pump / X-ray probe measurements were presented. Chapter 3 is devoted to the characterization and comparison of different types of X-ray optics. Chapter 4 presented the time-resolved X-ray diffraction experiments performed for this thesis. The first two sections of this chapter discuss the measurements of initially unexpected strain-induced transient changes of the integrated reflectivity of the X-ray probe beam. The elimination of the strain-induced transient changes of the integrated reflectivity represented an important prerequisite to perform the study of lattice heating in Germanium after femtosecond optical excitation by measuring the transient Debye-Waller effect. The third section describes the investigations of acoustic waves upon ultrafast optical excitation and discusses the two different pressure contributions driving them: the thermal and the electronic ones. (orig.)

  3. Direct observation of ultrafast atomic motion using time-resolved X-ray diffraction

    International Nuclear Information System (INIS)

    Shymanovich, U.

    2007-01-01

    This thesis is dedicated to the study of the atomic motion in laser irradiated solids on a picosecond to subpicosecond time-scale using the time-resolved X-ray diffraction technique. In the second chapter, the laser system, the laser-plasma based X-ray source and the experimental setup for optical pump / X-ray probe measurements were presented. Chapter 3 is devoted to the characterization and comparison of different types of X-ray optics. Chapter 4 presented the time-resolved X-ray diffraction experiments performed for this thesis. The first two sections of this chapter discuss the measurements of initially unexpected strain-induced transient changes of the integrated reflectivity of the X-ray probe beam. The elimination of the strain-induced transient changes of the integrated reflectivity represented an important prerequisite to perform the study of lattice heating in Germanium after femtosecond optical excitation by measuring the transient Debye-Waller effect. The third section describes the investigations of acoustic waves upon ultrafast optical excitation and discusses the two different pressure contributions driving them: the thermal and the electronic ones. (orig.)

  4. The nuclear physics program at SIS/ESR

    International Nuclear Information System (INIS)

    Henning, W.

    1991-01-01

    The present workshop discusses the physics program to be addressed with the new photon spectrometer TAPS. Part of this program will be carried out at the new accelerator facility SIS/ESR at GSI Darmstadt. To put the TAPS activities at SIS into perspective, an overview is given in the following discussing the new GSI facility, the research program under consideration and the various experimental facilities besides TAPS to carry out these studies. (orig.)

  5. Time-resolved MR angiography of the renal artery: morphology and perfusion

    International Nuclear Information System (INIS)

    Krause, U.J.; Pabst, T.; Koestler, H.; Helbig, C.; Kenn, W.; Hahn, D.

    2002-01-01

    Purpose: To prove the hypothesis that renal artery stenosis and changes in renal perfusion can be detected with contrast-enhanced time-resolved MR angiography in a single examination. Material and Methods: In 71 patients, 137 renal arteries and 14 accessory renal arteries were studied. The examinations were performed on a 1.5 T system. A T 1 -weighted gradient echo sequence with a temporal resolution of 7 s was used. Single dose of contrast material (0.1 mmol/kg Gd-DTPA) was injected with a power injector with a flow rate of 2 ml/s. Criterion for the assessment of renal perfusion was the slope ratio of the signal intensity time curve in both kidneys. Results: Forty renal artery stenoses and one occlusion of a renal artery were detected. In 48 kidneys (35%) segmental arteries were evaluated. The accuracy of the slope ratio (limit value 0.75) concerning the detection of unilateral renal artery stenosis was 92.6% (sensitivity 75%, specificity 95.7%). Conclusion: Time-resolved MR angiography can detect changes in renal perfusion in patients with unilateral renal artery stenosis. (orig.) [de

  6. Experiments with highly-charged heavy-ions performed at the storage ring ESR

    International Nuclear Information System (INIS)

    Mokler, P.H.

    1992-01-01

    The new heavy ion accelerator facility SIS/ESR was inaugurated in April 1990. During 1991 the experimental storage ring, ESR, has been commissioned. Highly-charged heavy ions from O 8+ up to Bi 82+ were successfully accumulated, cooled, and stored in the ring. Now all highly-charged, heavy ions can be provided for experiments at comfortable storage times and at energies roughly between 100 and 500 MeV/u. A report on the achievements and on the first experimental results will be given. For the experiments, special emphasis is put on capture processes in the electron cooler, i.e. on radiative and dielectronic recombination processes as well as on capture events of bound target electrons from a gas jet. In this case, the capture leads either directly (REC) or by cascading to X-ray emission, which is also exploited for a precision spectroscopy of the structure of the heaviest ions. Another exciting topic is the radioactive decay of highly charged ions: For instance the β-decay into bound atomic states, which is not possible for neutral atoms, was studied for stored naked Dy ions. (orig.)

  7. Study of the Bulk Charge Carrier Dynamics in Anatase and Rutile TiO2 Single Crystals by Femtosecond Time Resolved Spectroscopy

    KAUST Repository

    Maity, Partha; Mohammed, Omar F.; Katsiev, Khabiboulakh; Idriss, Hicham

    2018-01-01

    as the best model for fundamental studies. Their ultrafast charge carrier dynamics especially on TiO2 anatase single crystal (the most active phase) are unresolved. Here femtosecond time resolved spectroscopy (TRS) was carried out to explore the dynamics

  8. Preparation of alanine/ESR dosimeter using different binder of polymer blend

    International Nuclear Information System (INIS)

    Razzak, M.T.; Sudiro, Sutjipto; Sudradjat, Adjat; Waskito, Ashar; Djamili, M.F.

    1995-01-01

    Different composition of polymer blend of low density polyethylene (PE) and polystyrene (PS) have been studied to be used as a binder for the preparation of Alanine/ESR dosimeter. The polymer binder and Alanine powder were blended in Laboplastomil Mixer at 140 o C and then it was pressed into a plastic film of 0.50 mm thickness. The film was cut into sample size of 250 mm x 2.5 mm and irradiated by gamma rays from a cobalt-60 source at different dose and dose rate. It was found that a blend of Alanine, PS and PE in composition of 60:30:10 is appropriate to prepare the Alanine/ESR dosimeter. (author)

  9. Time-resolved far-infrared experiments at the National Synchrotron Light Source. Final report

    International Nuclear Information System (INIS)

    Tanner, D.B.; Reitze, D.H.; Carr, G.L.

    1999-01-01

    A facility for time-resolved infrared and far-infrared spectroscopy has been built and commissioned at the National Synchrotron Light Source. This facility permits the study of time dependent phenomena over a frequency range from 2-8000cm -1 (0.25 meV-1 eV). Temporal resolution is approximately 200 psec and time dependent phenomena in the time range out to 100 nsec can be investigated

  10. Time-resolved UV-excited microarray reader for fluorescence energy transfer (FRET) measurements

    Science.gov (United States)

    Orellana, Adelina; Hokkanen, Ari P.; Pastinen, Tomi; Takkinen, Kristina; Soderlund, Hans

    2001-05-01

    Analytical systems based on immunochemistry are largely used in medical diagnostics and in biotechnology. There is a significant pressure to develop the present assay formats to become easier to use, faster, and less reagent consuming. Further developments towards high density array--like multianalyte measurement systems would be valuable. To this aim we have studied the applicability of fluorescence resonance energy transfer and time-resolved fluorescence resonance energy transfer in immunoassays on microspots and in microwells. We have used engineered recombinant antibodies detecting the pentameric protein CRP as a model analyte system, and tested different assay formats. We describe also the construction of a time-resolved scanning epifluorometer with which we could measure the FRET interaction between the slow fluorescence decay from europium chelates and its energy transfer to the rapidly decaying fluorophore Cy5.

  11. Time-resolved diffraction studies of muscle using synchrotron radiation

    International Nuclear Information System (INIS)

    Harford, Jeffrey; Squire, John

    1997-01-01

    details the practical methods involved in recording time-resolved x-ray diffraction patterns from active muscles and the theoretical approaches that are being used to interpret the diffraction patterns that are obtained. The ultimate aim is to produce a series of time-sliced images of the changing molecular arrangements and shapes in the muscle as force is produced; together these images will form 'Muscle - The Movie'. (author)

  12. Time-resolved measurements of supersonic fuel sprays using synchrotron x-rays

    International Nuclear Information System (INIS)

    Powell, C.F.; Yue, Y.; Poola, R.; Wang, J.

    2000-11-01

    A time-resolved radiographic technique has been developed for probing the fuel distribution close to the nozzle of a high-pressure single-hole diesel injector. The measurement was made using X-ray absorption of monochromatic synchrotron-generated radiation, allowing quantitative determination of the fuel distribution in this optically impenetrable region with a time resolution of better than 1 μs. These quantitative measurements constitute the most detailed near-nozzle study of a fuel spray to date

  13. Time-resolved imaging of purely valence-electron dynamics during a chemical reaction

    DEFF Research Database (Denmark)

    Hockett, Paul; Bisgaard, Christer Z.; Clarkin, Owen J.

    2011-01-01

    Chemical reactions are manifestations of the dynamics of molecular valence electrons and their couplings to atomic motions. Emerging methods in attosecond science can probe purely electronic dynamics in atomic and molecular systems(1-6). By contrast, time-resolved structural-dynamics methods...... such as electron(7-10) or X-ray diffraction(11) and X-ray absorption(12) yield complementary information about the atomic motions. Time-resolved methods that are directly sensitive to both valence-electron dynamics and atomic motions include photoelectron spectroscopy(13-15) and high-harmonic generation(16......,17): in both cases, this sensitivity derives from the ionization-matrix element(18,19). Here we demonstrate a time-resolved molecular-frame photoelectron-angular-distribution (TRMFPAD) method for imaging the purely valence-electron dynamics during a chemical reaction. Specifically, the TRMFPADs measured during...

  14. Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

    International Nuclear Information System (INIS)

    Yeo, Inhwan Jason; Patyal, Baldev; Mandapaka, Anant; Jung, Jae Won; Yi, Byong Yong; Kim, Jong Oh

    2013-01-01

    Purpose: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams.Methods: The authors have designed the following test beams with variable beam holdoffs and dose rate regulations: a 10 × 10 cm open beam to serve as a reference beam; a sliding window (SW) beam utilizing the motion of a pair of multileaf collimator (MLC) leaves outside the 10 × 10 cm jaw; a step and shoot (SS) beam to move the pair in step; a volumetric modulated arc therapy (VMAT) beam. The beams were designed in such a way that they all produce the same open beam output of 10 × 10 cm. Time-resolved ion chamber measurements at isocenter and time-resolved and integrating EPID measurements were performed for all beams. The time-resolved EPID measurements were evaluated through comparison with the ion chamber and integrating EPID measurements, as the latter are accepted procedures. For two-dimensional, time-resolved evaluation, a VMAT beam with an infield MLC travel was designed. Time-resolved EPID measurements and Monte Carlo calculations of such EPID dose images for this beam were performed and intercompared.Results: For IMRT beams (SW and SS), the authors found disagreement greater than 2%, caused by frame missing of the time-resolved mode. However, frame missing disappeared, yielding agreement better than 2%, when the dose rate of irradiation (and thus the frame acquisition rates) reached a stable and planned rate as the dose of irradiation was raised past certain thresholds (a minimum 12 s of irradiation per shoot used for SS IMRT). For VMAT, the authors found that dose rate does not affect the frame acquisition rate, thereby causing no frame missing

  15. Neutron diffraction and ESR studies of pseudocubic Nd0.75Ba0.25MnO3 and its unusual critical behavior above TC

    International Nuclear Information System (INIS)

    Lazuta, A.V.; Ryzhov, V.A.; Smirnov, O.P.; Kiselev, I.A.; Chernenkov, Yu.P.; Borisov, S.A.; Troaynchuk, I.O.; Khalyavin, D.D.

    2006-01-01

    Results of structural neutron diffraction study and electron spin resonance (ESR) measurements are presented for insulating Nd 1-x Ba x MnO 3 (x=0.25) with the Curie temperature T C ∼129K. Its pseudocubic structure reveals the definite distortions to a lower symmetry. Detailed analysis of the data is performed in the frame of Pbnm space group in a temperature range 4.2-300K. The compound is found to exhibit the Jahn-Teller (JT) transition at T JT ∼250K. Character of the coherent JT distortions and their temperature evolution differ from those of the x=0.23 manganite. The ESR results correspond to behavior of a 3D isotropic ferromagnet above T*∼143K (τ*∼0.12= C )/T C ). It is shown that an anisotropic exchange coupling of the Mn and Nd magnetic moments may give a substantial contribution in ESR linewidth masking its critical enhancement. The different temperature treatments (slow/fast cooling/heating with/without external magnetic field) of the sample reveal a temperature hysteresis of the ESR spectra below T* indicating an anomalous response in the paramagnetic region. The study of the magnetic phase transition in the x=0.23 and 0.25 NdBa manganites suggests a change in its character from the second to first order at T*. The conventional free energy including the magnetization and magnetic field failed to describe this first-order transition. The unconventional critical behavior is attributed to an orbital liquid metallic phase that begins to coexist with the initial orbital-ordered phases below T*

  16. ESR study into mechanism of heterogeneous-catalytic oxidation on oxides

    Energy Technology Data Exchange (ETDEWEB)

    Topchieva, K V; Loginov, A Yu; Kostikov, S V [Moskovskij Gosudarstvennyj Univ. (USSR)

    1977-12-11

    The role of radical particles in heterogeneous-catalytic oxidation of H/sub 2/; CO; SO/sub 2/; NH/sub 3/; C/sub 3/H/sub 6/ on the rare earth oxides (yttrium, lanthanum, magnesium and scandium oxides) and alkaline earth metal oxides was studied by the ESR method. The conclusion was made about the great reactivity of the peroxide structures O/sub 2//sup -/ in the oxidation catalysis in comparison to other formulas of chemisorption oxigen on oxides. The kinetic investigations are chemisorption oxigen on oxides. The kinetic investigations are carried out on the change of the concentration of paramagnetic particles O/sub 2/ during the catalysis. On the basis of the received data the conclusion is made about the reaction process of catalytic oxidation on rare and alkaline-earth oxides according to radical-chain mechanism with the formation of radical particles O/sub 2//sup -/, CO/sub 3//sup -/, SO/sub 4//sup -/, CO/sub 2//sup -/ as interediate products.

  17. Characterization of free radicals in γ-irradiated polycrystalline uridine 5'-monophosphate: a study combining ESR, spin-trapping and HPLC

    International Nuclear Information System (INIS)

    Hiraoka, W.; Kuwabara, M.; Sato, F.

    1991-01-01

    Free radicals generated in γ-irradiated polycrystalline uridine 5'-monophosphate (5'-UMP) were studied by ESR, spin-trapping and high-performance liquid chromatography (HPLC). Although HPLC ultimately gave four spin-adducts, one component that was originally present disappeared during HPLC. Spin adducts due to two types of C6 radials were identified. One of these was thought to be formed by electron addition and subsequent protonation at the C6 position, and the other was presumed to be produced by electron addition and subsequent protonation at the O 4 position. The spin adducts derived from the C5 and C5' radicals were also identified. The spin adduct that disappeared during HPLC was thought to correspond to the C4'-centred radical. Computer simulation of ESR spectra was carried out to estimate the hyperfine splitting constants. (author)

  18. Femtosecond time-resolved vibrational SFG spectroscopy of CO/Ru( 0 0 1 )

    Science.gov (United States)

    Hess, Ch.; Wolf, M.; Roke, S.; Bonn, M.

    2002-04-01

    Vibrational sum-frequency generation (SFG) employing femtosecond infrared (IR) laser pulses is used to study the dynamics of the C-O stretch vibration on Ru(0 0 1). Time-resolved measurements of the free induction decay (FID) of the IR-polarization for 0.33 ML CO/Ru(0 0 1) exhibit single exponential decays over three decades corresponding to dephasing times of T2=1.94 ps at 95 K and T2=1.16 ps at 340 K. This is consistent with pure homogeneous broadening due to anharmonic coupling with the thermally activated low-frequency dephasing mode together with a contribution from saturation of the IR transition. In pump-probe SFG experiments using a strong visible (VIS) pump pulse the perturbation of the FID leads to transient line shifts even at negative delay times, i.e. when the IR-VIS SFG probe pair precedes the pump pulse. Based on an analysis of the time-dependent polarization we discuss the influence of the perturbed FID on time-resolved SFG spectra. We investigate how coherent effects affect the SFG spectra and we examine the time resolution in these experiments, in particular in dependence of the dephasing time.

  19. ESR modes in a Strong-Leg Ladder in the Tomonaga-Luttinger Liquid Phase

    Science.gov (United States)

    Zvyagin, S.; Ozerov, M.; Maksymenko, M.; Wosnitza, J.; Honecker, A.; Landee, C. P.; Turnbull, M.; Furuya, S. C.; Giamarchi, T.

    Magnetic excitations in the strong-leg quantum spin ladder compound (C7H10N)2CuBr4 (known as DIMPY) in the field-induced Tomonaga-Luttinger spin liquid phase are studied by means of high-field electron spin resonance (ESR) spectroscopy. The presence of a gapped ESR mode with unusual non-linear frequency-field dependence is revealed experimentally. Using a combination of analytic and exact diagonalization methods, we compute the dynamical structure factor and identify this mode with longitudinal excitations in the antisymmetric channel. We argue that these excitations constitute a fingerprint of the spin dynamics in a strong-leg spin-1/2 Heisenberg antiferromagnetic ladder and owe its ESR observability to the uniform Dzyaloshinskii-Moriya interaction. This work was partially supported by the DFG and Helmholtz Gemeinschaft (Germany), Swiss SNF under Division II, and ERC synergy UQUAM project. We acknowledge the support of the HLD at HZDR, member of the European Magnetic Field Laboratory (EMFL).

  20. An integrated approach using high time-resolved tools to study the origin of aerosols.

    Science.gov (United States)

    Di Gilio, A; de Gennaro, G; Dambruoso, P; Ventrella, G

    2015-10-15

    Long-range transport of natural and/or anthropogenic particles can contribute significantly to PM10 and PM2.5 concentrations and some European cities often fail to comply with PM daily limit values due to the additional impact of particles from remote sources. For this reason, reliable methodologies to identify long-range transport (LRT) events would be useful to better understand air pollution phenomena and support proper decision-making. This study explores the potential of an integrated and high time-resolved monitoring approach for the identification and characterization of local, regional and long-range transport events of high PM. In particular, the goal of this work was also the identification of time-limited event. For this purpose, a high time-resolved monitoring campaign was carried out at an urban background site in Bari (southern Italy) for about 20 days (1st-20th October 2011). The integration of collected data as the hourly measurements of inorganic ions in PM2.5 and their gas precursors and of the natural radioactivity, in addition to the analyses of aerosol maps and hourly back trajectories (BT), provided useful information for the identification and chemical characterization of local sources and trans-boundary intrusions. Non-sea salt (nss) sulfate levels were found to increase when air masses came from northeastern Europe and higher dispersive conditions of the atmosphere were detected. Instead, higher nitrate and lower nss-sulfate concentrations were registered in correspondence with air mass stagnation and attributed to local traffic source. In some cases, combinations of local and trans-boundary sources were observed. Finally, statistical investigations such as the principal component analysis (PCA) applied on hourly ion concentrations and the cluster analyses, the Potential Source Contribution Function (PSCF) and the Concentration Weighted Trajectory (CWT) models computed on hourly back-trajectories enabled to complete a cognitive framework

  1. Pulsed ESR measurements of oxygen deficient type centers in various quartz

    International Nuclear Information System (INIS)

    Yamanaka, C.; Kohno, H.; Ikeya, M.

    1996-01-01

    Phase-memory times T M for E'-centers in various quartz samples were measured by pulse-ESR. Manually ground quartz followed by γ-irradiation, α-irradiated quartz and that from a natural uranium deposit showed T M M of 15-18μs. Natural SiO 2 with dense spins, (∼ 3.96 Ga) and sandstone from an impact crater were also examined. (author)

  2. ESR identification of irradiated foodstuffs

    International Nuclear Information System (INIS)

    Raffi, J.

    1993-01-01

    The conditions required to use Electron Spin Resonance (ESR) in identification of irradiated foods is first described. Then we present the results of an intercomparison sponsored by the Community Bureau of Reference involving 22 european laboratories. Qualitative identification of irradiated beef bones, dried grapes and papaya is very easy. Kinetical studies are necessary in case of fish species. Further researches are required in case of pistachio-nuts. Although all laboratories could distinguish between the two dose ranges used in case of meat bones (i.e. 1-3 and 7-10 kGy), there is an overlap of the results from the different laboratories. 2 tabs., 3 figs

  3. A system for time-resolved x-ray diffraction and its application to muscle contraction

    International Nuclear Information System (INIS)

    Amemiya, Yoshiyuki; Hashizume, Hiroo.

    1979-01-01

    A data-collection system has been built which permits time-resolved studies of X-ray diffraction diagrams obtained from contracting muscle on millisecond time scale. The system consists of a linear delay-line position sensitive proportional counter (PSPC), a special data transfer unit and an on-line computer. The PSPC used with a mirror-monochromator camera can detect equatorial reflections from stimulated muscle in a total exposure time of a few seconds. Time-resolved data-collection is achieved by stimulating muscle at a regular time interval, dividing a complete cycle of muscle contraction into many successive time slices and accumulating in computer memory X-ray data for each time slice from many repeated cycles of stimulation. The performances of the system have been demonstrated by recording equatorial reflections from frog skeletal muscle during isometric and isotonic twitch with a time resolution of 25 ms. (author)

  4. Time-resolved protein nano-crystallography using an X-ray free-electron laser

    International Nuclear Information System (INIS)

    Aquila, Andrew; Hunter, Mark S.; Fromme, Petra; Fromme, Raimund; Grotjohann, Ingo; Doak, R. Bruce; Kirian, Richard A.; Schmidt, Kevin E.; Wang, Xiaoyu; Weierstall, Uwe; Spence, John C.H.; White, Thomas A.; Caleman, Carl; DePonte, Daniel P.; Fleckenstein, Holger; Gumprecht, Lars; Liang, Mengning; Martin, Andrew V.; Schulz, Joachim; Stellato, Francesco; Stern, Stephan; Barty, Anton; Andreasson, Jakob; Davidsson, Jan; Hajdu, Janos; Maia, Filipe R.N.C.; Seibert, M. Marvin; Timneanu, Nicusor; Arnlund, David; Johansson, Linda; Malmerberg, Erik; Neutze, Richard; Bajt, Sasa; Barthelmess, Miriam; Graafsma, Heinz; Hirsemann, Helmut; Wunderer, Cornelia; Barends, Thomas R.M.; Foucar, Lutz; Krasniqi, Faton; Lomb, Lukas; Rolles, Daniel; Schlichting, Ilme; Schmidt, Carlo; Bogan, Michael J.; Hampton, Christina Y.; Sierra, Raymond; Starodub, Dmitri; Bostedt, Christoph; Bozek, John D.; Messerschmidt, Marc; Williams, Garth J.; Bottin, Herve

    2012-01-01

    We demonstrate the use of an X-ray free electron laser synchronized with an optical pump laser to obtain X-ray diffraction snapshots from the photo-activated states of large membrane protein complexes in the form of nano-crystals flowing in a liquid jet. Light-induced changes of Photosystem I-Ferredoxin co-crystals were observed at time delays of 5 to 10 μs after excitation. The result correlates with the microsecond kinetics of electron transfer from Photosystem I to ferredoxin. The undocking process that follows the electron transfer leads to large rearrangements in the crystals that will terminally lead to the disintegration of the crystals. We describe the experimental setup and obtain the first time resolved femtosecond serial X-ray crystallography results from an irreversible photo-chemical reaction at the Linac Coherent Light Source. This technique opens the door to time-resolved structural studies of reaction dynamics in biological systems. (authors)

  5. Sub-nanosecond time-resolved near-field scanning magneto-optical microscope.

    Science.gov (United States)

    Rudge, J; Xu, H; Kolthammer, J; Hong, Y K; Choi, B C

    2015-02-01

    We report on the development of a new magnetic microscope, time-resolved near-field scanning magneto-optical microscope, which combines a near-field scanning optical microscope and magneto-optical contrast. By taking advantage of the high temporal resolution of time-resolved Kerr microscope and the sub-wavelength spatial resolution of a near-field microscope, we achieved a temporal resolution of ∼50 ps and a spatial resolution of microscope, the magnetic field pulse induced gyrotropic vortex dynamics occurring in 1 μm diameter, 20 nm thick CoFeB circular disks has been investigated. The microscope provides sub-wavelength resolution magnetic images of the gyrotropic motion of the vortex core at a resonance frequency of ∼240 MHz.

  6. Lucas–Kanade fluid trajectories for time-resolved PIV

    International Nuclear Information System (INIS)

    Yegavian, Robin; Leclaire, Benjamin; Illoul, Cédric; Losfeld, Gilles; Champagnat, Frédéric

    2016-01-01

    We introduce a new method for estimating fluid trajectories in time-resolved PIV. It relies on a Lucas–Kanade paradigm and consists in a simple and direct extension of a two-frame estimation with FOLKI-PIV (Champagnat et al 2011 Exp. Fluids 50 1169–82). The so-called Lucas–Kanade Fluid Trajectories (LKFT) are assumed to be polynomial in time, and are found as the minimizer of a global functional, in which displacements are sought so as to match the intensities of a series of images pairs in the sequence, in the least-squares sense. All pairs involve the central image, similar to other recent time-resolved approaches (FTC (Lynch and Scarano 2013 Meas. Sci. Technol . 24 035305) and FTEE (Jeon et al 2014 Exp. Fluids 55 1–16)). As switching from a two-frame to a time-resolved objective simply amounts to adding terms in a functional, no significant additional algorithmic element is required. Similar to FOLKI-PIV the method is very well suited for GPU acceleration, which is an important feature as computational complexity increases with the image sequence size. Tests on synthetic data exhibiting peak-locking show that increasing the image sequence size strongly reduces both associated bias and random error, and that LKFT has a remaining total error comparable to that of FTEE on this case. Results on case B of the third PIV challenge (Stanislas et al 2008 Exp. Fluids 45 27–71) also show its ability to drastically reduce the error in situations with low signal-to-noise ratio. These results are finally confirmed on experimental images acquired in the near-field of a low Reynolds number jet. Strong reductions in peak-locking, spatial and temporal noise compared to two-frame estimation are also observed, on the displacement components themselves, as well as on spatial or temporal derivatives, such as vorticity and material acceleration. (paper)

  7. Gauge invariance in the theoretical description of time-resolved angle-resolved pump/probe photoemission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Freericks, J. K.; Krishnamurthy, H. R.; Sentef, M. A.; Devereaux, T. P.

    2015-10-01

    Nonequilibrium calculations in the presence of an electric field are usually performed in a gauge, and need to be transformed to reveal the gauge-invariant observables. In this work, we discuss the issue of gauge invariance in the context of time-resolved angle-resolved pump/probe photoemission. If the probe is applied while the pump is still on, one must ensure that the calculations of the observed photocurrent are gauge invariant. We also discuss the requirement of the photoemission signal to be positive and the relationship of this constraint to gauge invariance. We end by discussing some technical details related to the perturbative derivation of the photoemission spectra, which involve processes where the pump pulse photoexcites electrons due to nonequilibrium effects.

  8. Polymorphisms in the LPL and CETP Genes and Haplotype in the ESR1 Gene Are Associated with Metabolic Syndrome in Women from Southwestern Mexico

    Directory of Open Access Journals (Sweden)

    José Ángel Cahua-Pablo

    2015-09-01

    Full Text Available Metabolic syndrome (MetS is a combination of metabolic disorders associated with an increased risk for cardiovascular disease (CVD. Studies in women reported associations between polymorphisms in ESR1, LPL and CETP genes and MetS. Our aim was to evaluate the association between variants in ESR1, LPL and CETP genes with MetS and its components. Four hundred and eighty women were analyzed, anthropometric features and biochemical profiles were evaluated, and genotyping was performed by real-time PCR. We found an association with elevated glucose levels (odds ratio (OR = 2.9; p = 0.013 in carrying the AA genotype of rs1884051 in the ESR1 gene compared with the GG genotype, and the CC genotype of rs328 in the LPL gene was associated with MetS compared to the CG or GG genotype (OR = 2.8; p = 0.04. Moreover, the GA genotype of rs708272 in the CETP gene is associated with MetS compared to the GG or AA genotype (OR = 1.8; p = 0.006. In addition the ACTCCG haplotype in the ESR1 gene is associated with a decrease in the risk of MetS (OR = 0.02; p < 0.001. In conclusion, our results show the involvement of the variants of ESR1, LPL and CETP genes in metabolic events related to MetS or some of its features.

  9. Penetration route of functional molecules in stratum corneum studied by time-resolved small- and wide-angle x-ray diffraction

    International Nuclear Information System (INIS)

    Hatta, Ichiro; Ohta, Noboru; Yagi, Naoto; Nakazawa, Hiromitsu; Obata, Yasuko; Inoue, Katsuaki

    2011-01-01

    We studied effects of functional molecules on corneocytes in stratum corneum using time-resolved small- and wide-angle x-ray diffraction after applying a functional molecule. From these results it was revealed that in the stratum corneum a typical hydrophilic molecule, ethanol, penetrates via the transcellular route and on the other hand a typical hydrophobic molecule, d-limonene, penetrates via the intercellular route.

  10. Detecting aromatic compounds on planetary surfaces using ultraviolet time-resolved fluorescence spectroscopy

    Science.gov (United States)

    Eshelman, E.; Daly, M. G.; Slater, G.; Cloutis, E.

    2018-02-01

    Many aromatic organic molecules exhibit strong and characteristic fluorescence when excited with ultraviolet radiation. As laser excitation in the ultraviolet generates both fluorescence and resonantly enhanced Raman scattering of aromatic vibrational modes, combined Raman and fluorescence instruments have been proposed to search for organic compounds on Mars. In this work the time-resolved fluorescence of a suite of 24 compounds composed of 2-5 ringed alternant, non-alternant, and heterocyclic PAHs was measured. Fluorescence instrumentation with similar specifications to a putative flight instrument was capable of observing the fluorescence decay of these compounds with a sub-ns resolution. Incorporating time-resolved capabilities was also found to increase the ability to discriminate between individual PAHs. Incorporating time-resolved fluorescence capabilities into an ultraviolet gated Raman system intended for a rover or lander can increase the ability to detect and characterize PAHs on planetary surfaces.

  11. Time-resolved PHERMEX image restorations constrained with an additional multiply-exposed image

    International Nuclear Information System (INIS)

    Kruger, R.P.; Breedlove, J.R. Jr.; Trussell, H.J.

    1978-06-01

    There are a number of possible industrial and scientific applications of nanosecond cineradiographs. Although the technology exists to produce closely spaced pulses of x rays for this application, the quality of the time-resolved radiographs is severely limited. The limitations arise from the necessity of using a fluorescent screen to convert the transmitted x rays to light and then using electro-optical imaging systems to gate and to record the images with conventional high-speed cameras. It has been proposed that, in addition to the time-resolved images, a conventional multiply exposed radiograph be obtained. This report uses both PHERMEX and conventional photographic simulations to demonstrate that the additional information supplied by the multiply exposed radiograph can be used to improve the quality of digital image restorations of the time-resolved pictures over what could be achieved with the degraded images alone

  12. Time-resolved photoelectron spectroscopy of nitrobenzene and its aldehydes

    Science.gov (United States)

    Schalk, Oliver; Townsend, Dave; Wolf, Thomas J. A.; Holland, David M. P.; Boguslavskiy, Andrey E.; Szöri, Milan; Stolow, Albert

    2018-01-01

    We report the first femtosecond time-resolved photoelectron spectroscopy study of 2-, 3- and 4-nitrobenzaldehyde (NBA) and nitrobenzene (NBE) in the gas phase upon excitation at 200 nm. In 3- and 4-NBA, the dynamics follow fast intersystem crossing within 1-2 picoseconds. In 2-NBA and NBE, the dynamics are faster (∼ 0.5 ps). 2-NBA undergoes hydrogen transfer similar to solution phase dynamics. NBE either releases NO2 in the excited state or converts internally back to the ground state. We discuss why these channels are suppressed in the other nitrobenzaldehydes.

  13. Transient photoconductivity in InGaN/GaN multiple quantum wells, measured by time-resolved terahertz spectroscopy

    DEFF Research Database (Denmark)

    Porte, Henrik; Turchinovich, Dmitry; Cooke, David

    2009-01-01

    Terahertz conductivity of InGaN/GaN MQWs was studied by time-resolved terahertz spectroscopy. Restoration of the built-in piezoelectric field leads to a nonexponential carrier density decay. Terahertz conductivity spectrum is described by the Drude-Smith......Terahertz conductivity of InGaN/GaN MQWs was studied by time-resolved terahertz spectroscopy. Restoration of the built-in piezoelectric field leads to a nonexponential carrier density decay. Terahertz conductivity spectrum is described by the Drude-Smith...

  14. The influence of measurement and storage conditions on alanine ESR dosimeters

    International Nuclear Information System (INIS)

    Alexandre, A.C.

    1992-01-01

    Alanine has several desirable properties as an ESR dosemeter e.g. tissue equivalence, low fading and an approximately linear response for doses up to 10 kGy. This work reports on a simple system to produce the alanine dosemeter, the signal intensity for a range of doses and energies, and the effect of the air humidity and the spectrometer settings on the ESR signal. (Author)

  15. Time-resolved detection of surface plasmon polaritons with a scanning tunneling microscope

    DEFF Research Database (Denmark)

    Keil, Ulrich Dieter Felix; Ha, T.; Jensen, Jacob Riis

    1998-01-01

    We present the time-resolved detection of surface plasmon polaritons with an STM. The results indicate that the time resolved signal is due to rectification of coherently superimposed plasmon voltages. The comparison with differential reflectivity measurements shows that the tip itself influences...... the decay of the plasmon-field coherence. Generation of the measured signal at the tunneling junction offers the possibility to observe ultrafast effects with a spatial resolution determined by the tunneling junction...

  16. Multi-frequency ESR studies on a Haldane magnet in a field-induced phase at ultra-low temperatures

    International Nuclear Information System (INIS)

    Hagiwara, Masayuki; Kashiwagi, Takanari; Idutsu, Yuichi; Honda, Zentaro; Miyazaki, Hiroshi; Harada, Isao

    2010-01-01

    We report the results of multi-frequency electron spin resonance (ESR) measurements on single crystals of Ni(C 5 H 14 N 2 ) 2 N 3 (PF 6 ) which is regarded as the one-dimensional Heisenberg antiferromagnet with spin one, namely the Haldane magnet, at very low temperatures down to about 100 mK. We observed the lowest resonance branch below about 500 mK for the field along the chain direction (H||c), which was observed previously only in an inelastic neutron scattering experiment at 30 mK. We compare the resonance branch with that calculated by a phenomenological field theory, and discuss the field dependence and the temperature sensitivity of this ESR branch.

  17. Time-resolved explosion of intense-laser-heated clusters.

    Science.gov (United States)

    Kim, K Y; Alexeev, I; Parra, E; Milchberg, H M

    2003-01-17

    We investigate the femtosecond explosive dynamics of intense laser-heated argon clusters by measuring the cluster complex transient polarizability. The time evolution of the polarizability is characteristic of competition in the optical response between supercritical and subcritical density regions of the expanding cluster. The results are consistent with time-resolved Rayleigh scattering measurements, and bear out the predictions of a recent laser-cluster interaction model [H. M. Milchberg, S. J. McNaught, and E. Parra, Phys. Rev. E 64, 056402 (2001)

  18. Time-resolved explosion of intense-laser-heated clusters

    International Nuclear Information System (INIS)

    Kim, K.Y.; Alexeev, I.; Parra, E.; Milchberg, H.M.

    2003-01-01

    We investigate the femtosecond explosive dynamics of intense laser-heated argon clusters by measuring the cluster complex transient polarizability. The time evolution of the polarizability is characteristic of competition in the optical response between supercritical and subcritical density regions of the expanding cluster. The results are consistent with time-resolved Rayleigh scattering measurements, and bear out the predictions of a recent laser-cluster interaction model [H. M. Milchberg, S. J. McNaught, and E. Parra, Phys. Rev. E 64, 056402 (2001)

  19. Time-resolved x-ray laser induced photoelectron spectroscopy of isochoric heated copper

    International Nuclear Information System (INIS)

    Nelson, A.J.; Dunn, J.; Hunter, J.; Widmann, K.

    2005-01-01

    Time-resolved x-ray photoelectron spectroscopy is used to probe the nonsteady-state evolution of the valence band electronic structure of laser heated ultrathin (50 nm) copper. A metastable phase is studied using a 527 nm wavelength 400 fs laser pulse containing 0.1-2.5 mJ laser energy focused in a large 500x700 μm 2 spot to create heated conditions of 0.07-1.8x10 12 W cm -2 intensity. Valence band photoemission spectra are presented showing the changing occupancy of the Cu 3d level with heating are presented. These picosecond x-ray laser induced time-resolved photoemission spectra of laser-heated ultrathin Cu foil show dynamic changes in the electronic structure. The ultrafast nature of this technique lends itself to true single-state measurements of shocked and heated materials

  20. Time-resolved x-ray line diagnostics of laser-produced plasmas

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Matthews, D.L.; Kilkenny, J.D.; Lee, R.W.

    1982-11-01

    We have examined the underdense plasma conditions of laser irradiated disks using K x-rays from highly ionized ions. A 900 ps laser pulse of 0.532 μm light is used to irradiate various Z disks which have been doped with low concentrations of tracer materials. The tracers, whose Z's range from 13 to 22, are chosen so that their K x-ray spectrum is sensitive to typical underdense plasma temperatures and densities. Spectra are measured using a time-resolved crystal spectrograph recording the time history of the x-ray spectrum. A spatially-resolved, time-integrated crystal spectrograph also monitors the x-ray lines. Large differences in Al spectra are observed when the host plasms is changed from SiO 2 to PbO or In. Spectra will be presented along with preliminary analysis of the data

  1. Time-resolved x-ray line diagnostics of laser-produced plasmas

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Matthews, D.L.; Kilkenny, J.D.; Lee, R.W.

    1982-01-01

    We have examined the underdense plasma conditions of laser irradiated disks using K x-rays from highly ionized ions. A 900 ps laser pulse of 0.532 μm light is used to irradiate various Z disks which have been doped with low concentrations of tracer materials. The tracers whose Z's range from 13 to 22 are chosen so that their K x-ray spectrum is sensitive to typical underdense plasma temperatures and densities. Spectra are measured using a time-resolved crystal spectrograph recording the time history of the x-ray spectrum. A spatially-resolved, time-integrated crystal spectrograph also monitors the x-ray lines. Large differences in Al spectra are observed when the host plasma is changed from SiO 2 to PbO or In. Spectra will be presented along with preliminary analysis of the data

  2. l-Tryptophan Radical Cation Electron Spin Resonance Studies: Connecting Solution-derived Hyperfine Coupling Constants with Protein Spectral Interpretations

    Science.gov (United States)

    Connor, Henry D.; Sturgeon, Bradley E.; Mottley, Carolyn; Sipe, Herbert J.; Mason, Ronald P.

    2009-01-01

    Fast-flow electron spin resonance (ESR) spectroscopy has been used to detect a free radical formed from the reaction of l-tryptophan with Ce4+ in an acidic aqueous environment. Computer simulations of the ESR spectra from l-tryptophan and several isotopically modified forms strongly support the conclusion that the l-tryptophan radical cation has been detected by ESR for the first time. The hyperfine coupling constants (HFCs) determined from the well-resolved isotropic ESR spectra support experimental and computational efforts to understand l-tryptophan's role in protein catalysis of oxidation-reduction processes. l-tryptophan HFCs facilitated the simulation of fast-flow ESR spectra of free radicals from two related compounds, tryptamine and 3-methylindole. Analysis of these three compounds' β-methylene hydrogen HFC data along with equivalent l-tyrosine data has led to a new computational method that can distinguish between these two amino acid free radicals in proteins without dependence on isotope labeling, electron nuclear double resonance or high-field ESR. This approach also produces geometric parameters (dihedral angles for the β-methylene hydrogens) which should facilitate protein site assignment of observed l-tryptophan radicals as has been done for l-tyrosine radicals. PMID:18433127

  3. Time- and Space-Resolved Spectroscopic Investigation on Pi-Conjugated Nanostructures - 2

    Science.gov (United States)

    2016-01-12

    Defocused wide-field fluorescence (DWFI) microscopy suggests that molecular heterogeneities and flexibilities clearly depend on ring size and that site... Confocal   Microscopy   Setup Wild‐field  Microscopy   Setup Femtosecond Z‐scan  experiment Setup Figure 3. Instruments of Time- and space-resolved...approved for public release. 3. Space-Resolved Laser Spectroscopy - Confocal Microscopy - Wild-field Microscopy 4. Non-Linear Spectroscopy

  4. Time and spectrum-resolving multiphoton correlator for 300–900 nm

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, Kelsey D.; Thibault, Marilyne; Jennewein, Thomas [Institute for Quantum Computing and Department for Physics and Astronomy, University of Waterloo, 200 University Ave. West, Waterloo, Ontario N2L 3G1 (Canada); Kolenderski, Piotr, E-mail: kolenderski@fizyka.umk.pl [Institute for Quantum Computing and Department for Physics and Astronomy, University of Waterloo, 200 University Ave. West, Waterloo, Ontario N2L 3G1 (Canada); Faculty of Physics, Astronomy and Informatics, Institute of Physics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Scarcella, Carmelo; Tosi, Alberto [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy)

    2014-10-14

    We demonstrate a single-photon sensitive spectrometer in the visible range, which allows us to perform time-resolved and multi-photon spectral correlation measurements at room temperature. It is based on a monochromator composed of two gratings, collimation optics, and an array of single photon avalanche diodes. The time resolution can reach 110 ps and the spectral resolution is 2 nm/pixel, limited by the design of the monochromator. This technique can easily be combined with commercial monochromators and can be useful for joint spectrum measurements of two photons emitted in the process of parametric down conversion, as well as time-resolved spectrum measurements in optical coherence tomography or medical physics applications.

  5. Time-resolved measurement of global synchronization in the dust acoustic wave

    Science.gov (United States)

    Williams, J. D.

    2014-10-01

    A spatially and temporally resolved measurement of the synchronization of the naturally occurring dust acoustic wave to an external drive and the relaxation from the driven wave mode back to the naturally occuring wave mode is presented. This measurement provides a time-resolved measurement of the synchronization of the self-excited dust acoustic wave with an external drive and the return to the self-excited mode. It is observed that the wave synchronizes to the external drive in a distinct time-dependent fashion, while there is an immediate loss of synchronization when the external modulation is discontinued.

  6. New layout of time resolved beam energy spectrum measurement for dragon-I

    International Nuclear Information System (INIS)

    Liao Shuqing; Zhang Kaizhi; Shi Jinshui

    2010-01-01

    A new layout of time resolved beam energy spectrum measurement is proposed for Dragon-I by a new method named RBS (rotating beams in solenoids). The basic theory of RBS and the new layout are presented and the measuring error is also discussed. The derived time resolved beam energy spectrum is discrete and is determined by measuring the beam's rotating angle and expanding width through a group of solenoids at the export of Dragon-I. (authors)

  7. ESR Study Applied To Thermal Stability Of Radiation-Induced Species Of Solid Ketoprofen

    International Nuclear Information System (INIS)

    Maltar-Strmecki, N.; Katusin-Razem, B.; Razem, D.

    2015-01-01

    Ketoprofen [2-(3-benzoylphenyl) propionic acid] is a non-steroidal anti-inflammatory drug. It has been widely used in human and veterinary medicine. Radiation processing of drugs and its ingredients is recognized as a safe and effective method among the existing technologies for sterilization and protocols that can be found in ISO 11137-1. Radiosterilization of drugs or other medical products by a suitable dose of ionizing radiation conducted in an appropriate environment ensures sterile conditions by destroying or removing vegetative and sporulating microbes from the ingredients or environment. In earlier studies the effects of gamma radiation was evaluated by selected physico-chemical methods and the observations showed that solid ketoprofen is relatively stable toward ionizing irradiation and that radiosterilization might be a suitable method for the sterilization of solid ketoprofen. The studies reported in this work were undertaken to analyse thermal stability of free radicals by accelerated aging method with a view to the determination of shelf-life. The expiration date (shelf-life) of a product is based on evaluation of both, thermal stability of free radicals, as well as on the time evolution of stable radiolysis products. Namely, storage time is determined by the time required by any degradation product in the dosage form to achieve a sufficient level to represent a risk to the patient. This work shows that ESR spectroscopy provides means for determination of thermal stability of radicals induced by gamma-irradiation in solid drugs. Therefore, despite the complex mixture of individual free radicals induced by gamma-irradiation in solid ketoprofen, the overall lifetime of free radicals could be determined by using isothermal and isochronal annealing. This study shows that radicals induced by gamma-irradiation in solid ketoprofen are stable for at least about 6 months. (author).

  8. Decay time shortening of fluorescence from donor-acceptor pair proteins using ultrafast time-resolved fluorescence resonance energy transfer spectroscopy

    International Nuclear Information System (INIS)

    Baba, Motoyoshi; Suzuki, Masayuki; Ganeev, Rashid A.; Kuroda, Hiroto; Ozaki, Tsuneyuki; Hamakubo, Takao; Masuda, Kazuyuki; Hayashi, Masahiro; Sakihama, Toshiko; Kodama, Tatsuhiko; Kozasa, Tohru

    2007-01-01

    We improved an ultrafast time-resolved fluorescence resonance energy transfer (FRET) spectroscopy system and measured directly the decrease in the fluorescence decay time of the FRET signal, without any entanglement of components in the picosecond time scale from the donor-acceptor protein pairs (such as cameleon protein for calcium ion indicator, and ligand-activated GRIN-Go proteins pair). The drastic decrease in lifetime of the donor protein fluorescence under the FRET condition (e.g. a 47.8% decrease for a GRIN-Go protein pair) proves the deformation dynamics between donor and acceptor fluorescent proteins in an activated state of a mixed donor-acceptor protein pair. This study is the first clear evidence of physical contact of the GRIN-Go proteins pair using time-resolved FRET system. G protein-coupled receptors (GPCRs) are the most important protein family for the recognition of many chemical substances at the cell surface. They are the targets of many drugs. Simultaneously, we were able to observe the time-resolved spectra of luminous proteins at the initial stage under the FRET condition, within 10 ns from excitation. This new FRET system allows us to trace the dynamics of the interaction between proteins at the ligand-induced activated state, molecular structure change and combination or dissociation. It will be a key technology for the development of protein chip technology

  9. Self-assembled organic radicals on Au(111) surfaces: a combined ToF-SIMS, STM, and ESR study.

    Science.gov (United States)

    Mannini, Matteo; Sorace, Lorenzo; Gorini, Lapo; Piras, Federica M; Caneschi, Andrea; Magnani, Agnese; Menichetti, Stefano; Gatteschi, Dante

    2007-02-27

    Electron spin resonance (ESR), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and scanning tunneling microscopy (STM) have been used in parallel to characterize the deposition on gold surface of a series of nitronyl nitroxide radicals. These compounds have been specifically synthesized with methyl-thio linking groups suitable to interact with the gold surface to form self-assembled monolayers (SAMs), which can be considered relevant in the research for molecular-based spintronics devices, as suggested in recent papers. The degree of the expected ordering on the surface of these SAMs has been tuned by varying the chemical structure of synthesized radicals. ToF-SIMS has been used to support the evidence of the occurrence of the deposition process. STM has shown the different qualities of the obtained SAMs, with the degree of local order increasing as the degree of freedom of the molecules on the surface is decreased. Finally, ESR has confirmed that the deposition process does not affect the paramagnetic characteristics of radicals and that it affords a complete single-layered coverage of the surface. Further, the absence of angular dependence in the spectra indicates that the small regions of local ordering do not give rise to a long-range order and suggests a quite large mobility of the radical on the surface, probably due to the weak interaction with gold provided by the methyl-thio linking group.

  10. Time-Resolved PIV for Space-Time Correlations in Hot Jets

    Science.gov (United States)

    Wernet, Mark P.

    2007-01-01

    Temporally Resolved Particle Image Velocimetry (TR-PIV) is being used to characterize the decay of turbulence in jet flows a critical element for understanding the acoustic properties of the flow. A TR-PIV system, developed in-house at the NASA Glenn Research Center, is capable of acquiring planar PIV image frame pairs at up to 10 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered 6 nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centered along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space-time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

  11. Time-resolved luminescence from feldspars: New insight into fading

    DEFF Research Database (Denmark)

    Tsukamoto, S.; Denby, P.M.; Murray, A.S.

    2006-01-01

    Time-resolved infrared optically stimulated luminescence (IR-OSL) signals of K- and Na-feldspar samples extracted from sediments were measured in UV, blue and red detection windows, using a fast photon counter and pulsed IR stimulation (lambda = 875 nm). We observe that the relative contribution ...

  12. ESR and X-ray diffraction studies on thin films of poly-3-hexylthiophene: Molecular orientation and magnetic interactions

    International Nuclear Information System (INIS)

    Sugiyama, Keisuke; Kojima, Takashi; Fukuda, Hisashi; Yashiro, Hisashi; Matsuura, Toshihiko; Shimoyama, Yuhei

    2008-01-01

    Poly-3-hexylthiophene (P3HT) thin films were investigated by X-ray diffraction (XRD) and electron spin resonance (ESR) to reveal the film structure and molecular organization. The XRD data showed a diffraction pattern with a plane separation between the planes containing thiophene rings of 16.0 A. Comparison between the XRD patterns of powder and thin films of P3HT suggests that the main chains are folded on the substrate. Angular variation of the line position (g-value) of ESR spectra revealed that thiophene ring of P3HT orients along the substrate normal axis. The ESR linewidth varied by the angular rotation, indicating the one-dimensional spin-chain interactions in the P3HT thin films with a linear network of spin-chains. An organic thin-film transistor (OTFT) with P3HT film as a channel layer was then demonstrated. The P3HT films showed conducting characteristics with holes as carriers. The OTFTs indicated a field-effect mobility of 4.93 x 10 -3 cm 2 /Vs and an on/off ratio of 73 in the accumulation mode

  13. ESR study of /sup 99/Tc(II) complex formed by reduction of ammonium pertechnetate with ascorbic acid in concentrated hydrochloric acid

    Energy Technology Data Exchange (ETDEWEB)

    Kudo, T; Tsuchihashi, N; Ogata, T

    1987-07-30

    Paramagnetic /sup 99/Tc complex formed by the reduction of ammonium pertechnetate by ascorbic acid with excess sodium nitrite in concentrated hydrochloric acid was investigated by ESR technique. This complex had total electron spin S=1/2 and the obtained ESR parameters are 2.032, 2.043; and 264, 108 gauss, respectively. It was concluded that the formed species was low spin /sup 99/Tc(II) complex. (author) 13 refs.

  14. Kinetics of the reaction F+NO+M->FNO+M studied by pulse radiolysis combined with time-resolved IR and UV spectroscopy

    DEFF Research Database (Denmark)

    Pagsberg, Palle Bjørn; Sillesen, A.; Jodkowski, J.T.

    1996-01-01

    The title reaction was initiated by pulse radiolysis of SF6/NO gas mixtures, and the formation of FNO was studied by time-resolved IR and UV spectroscopy. At SF6 pressures of 10-320 mbar at 298 K, the formation of FNO was studied by infrared diode laser spectroscopy at 1857.324 cm(-1). Comparative...

  15. Relaxation behavior of radicals produced in irradiated black pepper under various moisture conditions by ESR

    International Nuclear Information System (INIS)

    Kameya, Hiromi; Kawauchi, Risa; Shimoyama, Yuhei; Kaeda, Yoko; Ogawa, Satoko; Nakamura, Hideo; Ukai, Mitsuko

    2008-01-01

    Black pepper is easy to be contaminated by microorganism and often processed to γ-irradiation. ESR has been used for the detection of radicals induced in irradiated spices. Using ESR, we revealed the effects of moisture condition during storage of irradiated black pepper on the saturation behavior of ESR signal. The ESR spectrum of black pepper consists of a broad sextet centered at g=2.0, a singlet as same g-value and a singlet at g=4.0. The irradiation causes two new signals, one is the strong and sharp singlet signal at g=2.0 and the other is the side signal. We found that the signal intensity originated by the radicals of black pepper with and without radiation decayed in the high humidity condition during storage. The ESR signal intensity of irradiated black pepper decayed during storage and showed almost the same intensity level as that of non-irradiated black pepper during storage. (author)

  16. Time-resolved spectroscopy defines perturbation in molecules

    International Nuclear Information System (INIS)

    Ahmed, K.

    1998-01-01

    Time-resolved LIF spectroscopy is employed in order to investigate perturbations in different excited electronic state of alkali molecules. Dunham Coefficients are used to search the selected excited ro-vibrational level, which is overlap with the other nearby excited states. Lifetime measurement has been performed of more than 50 ro-vibrational levels. Out of these 25 levels were observed drastically different lifetimes from the other unperturbed levels. In this report, influence of different perturbations on this anomalous behavior is investigated and discussed. (author)

  17. Simultaneous CXCL12 and ESR1 CpG island hypermethylation correlates with poor prognosis in sporadic breast cancer

    International Nuclear Information System (INIS)

    Ramos, Edneia AS; Klassen, Giseli; Camargo, Anamaria A; Braun, Karin; Slowik, Renata; Cavalli, Iglenir J; Ribeiro, Enilze MSF; Pedrosa, Fábio de O; Souza, Emanuel M de; Costa, Fabrício F

    2010-01-01

    CXCL12 is a chemokine that is constitutively expressed in many organs and tissues. CXCL12 promoter hypermethylation has been detected in primary breast tumours and contributes to their metastatic potential. It has been shown that the oestrogen receptor α (ESR1) gene can also be silenced by DNA methylation. In this study, we used methylation-specific PCR (MSP) to analyse the methylation status in two regions of the CXCL12 promoter and ESR1 in tumour cell lines and in primary breast tumour samples, and correlated our results with clinicopathological data. First, we analysed CXCL12 expression in breast tumour cell lines by RT-PCR. We also used 5-aza-2'-deoxycytidine (5-aza-CdR) treatment and DNA bisulphite sequencing to study the promoter methylation for a specific region of CXCL12 in breast tumour cell lines. We evaluated CXCL12 and ESR1 methylation in primary tumour samples by methylation-specific PCR (MSP). Finally, promoter hypermethylation of these genes was analysed using Fisher's exact test and correlated with clinicopathological data using the Chi square test, Kaplan-Meier survival analysis and Cox regression analysis. CXCL12 promoter hypermethylation in the first region (island 2) and second region (island 4) was correlated with lack of expression of the gene in tumour cell lines. In the primary tumours, island 2 was hypermethylated in 14.5% of the samples and island 4 was hypermethylated in 54% of the samples. The ESR1 promoter was hypermethylated in 41% of breast tumour samples. In addition, the levels of ERα protein expression diminished with increased frequency of ESR1 methylation (p < 0.0001). This study also demonstrated that CXCL12 island 4 and ESR1 methylation occur simultaneously at a high frequency (p = 0.0220). This is the first study showing a simultaneous involvement of epigenetic regulation for both CXCL12 and ESR1 genes in Brazilian women. The methylation status of both genes was significantly correlated with histologically advanced

  18. ESR investigations of gamma irradiated beryllium ceramics

    International Nuclear Information System (INIS)

    Ryabikin, Yu.A.; Polyakov, A.I.; Petukhov, Yu.V.; Bitenbaev, M.I.; Zashkvara, O.V.

    2000-01-01

    In this report the result of ESR- investigation of kinetics of radiation paramagnetic defects accumulated in beryllium ceramics under gamma irradiation are presented. The data on quantum yield and destruction rate constants of these defects under ionizing irradiation are obtained. (orig.)

  19. ESR investigations of gamma irradiated beryllium ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Ryabikin, Yu A; Polyakov, A I; Petukhov, Yu V; Bitenbaev, M I; Zashkvara, O V [Physical-Technical Inst., Almaty (Kazakhstan)

    2000-04-01

    In this report the result of ESR- investigation of kinetics of radiation paramagnetic defects accumulated in beryllium ceramics under gamma irradiation are presented. The data on quantum yield and destruction rate constants of these defects under ionizing irradiation are obtained. (orig.)

  20. Space- and time-resolved raman and breakdown spectroscopy: advanced lidar techniques

    Science.gov (United States)

    Silviu, Gurlui; Marius Mihai, Cazacu; Adrian, Timofte; Oana, Rusu; Georgiana, Bulai; Dimitriu, Dan

    2018-04-01

    DARLIOES - the advanced LIDAR is based on space- and time-resolved RAMAN and breakdown spectroscopy, to investigate chemical and toxic compounds, their kinetics and physical properties at high temporal (2 ns) and spatial (1 cm) resolution. The high spatial and temporal resolution are needed to resolve a large variety of chemical troposphere compounds, emissions from aircraft, the self-organization space charges induced light phenomena, temperature and humidity profiles, ice nucleation, etc.

  1. Dosimetric calibration of humidity chamber inside the 60Co-PANBIT irradiator using alanine ESR dosimeter

    International Nuclear Information System (INIS)

    Murali, S.; Venkataramani, R.; Pushparaja; Natarajan, V.; Sastry, M.D.; Bora, J.S.; Venkatacharyulu, K.

    1998-01-01

    In the present work the suitability of the electron spin resonance (ESR) technique, using DL - α - alanine sample is examined. It is well documented that radiation induced free radicals in alanine give strong ESR spectrum which can be used for dosimetry purposes. The aspects that are relevant to the present work are: (I) stability of the radicals in temperature and humidity conditions in which the experiments were carried out; (II) linearity at high doses; and (III) establishing the utility of alanine ESR dosimeter by cross checking the dose values with more established dosimeters. The details of these investigations are presented and it is shown that alanine ESR dosimeter will meet all the required conditions satisfactorily

  2. Association of ESR1 gene tagging SNPs with breast cancer risk

    Science.gov (United States)

    Dunning, Alison M.; Healey, Catherine S.; Baynes, Caroline; Maia, Ana-Teresa; Scollen, Serena; Vega, Ana; Rodríguez, Raquel; Barbosa-Morais, Nuno L.; Ponder, Bruce A.J.; Low, Yen-Ling; Bingham, Sheila; Haiman, Christopher A.; Le Marchand, Loic; Broeks, Annegien; Schmidt, Marjanka K.; Hopper, John; Southey, Melissa; Beckmann, Matthias W.; Fasching, Peter A.; Peto, Julian; Johnson, Nichola; Bojesen, Stig E.; Nordestgaard, Børge; Milne, Roger L.; Benitez, Javier; Hamann, Ute; Ko, Yon; Schmutzler, Rita K.; Burwinkel, Barbara; Schürmann, Peter; Dörk, Thilo; Heikkinen, Tuomas; Nevanlinna, Heli; Lindblom, Annika; Margolin, Sara; Mannermaa, Arto; Kosma, Veli-Matti; Chen, Xiaoqing; Spurdle, Amanda; Change-Claude, Jenny; Flesch-Janys, Dieter; Couch, Fergus J.; Olson, Janet E.; Severi, Gianluca; Baglietto, Laura; Børresen-Dale, Anne-Lise; Kristensen, Vessela; Hunter, David J.; Hankinson, Susan E.; Devilee, Peter; Vreeswijk, Maaike; Lissowska, Jolanta; Brinton, Louise; Liu, Jianjun; Hall, Per; Kang, Daehee; Yoo, Keun-Young; Shen, Chen-Yang; Yu, Jyh-Cherng; Anton-Culver, Hoda; Ziogoas, Argyrios; Sigurdson, Alice; Struewing, Jeff; Easton, Douglas F.; Garcia-Closas, Montserrat; Humphreys, Manjeet K.; Morrison, Jonathan; Pharoah, Paul D.P.; Pooley, Karen A.; Chenevix-Trench, Georgia

    2009-01-01

    We have conducted a three-stage, comprehensive single nucleotide polymorphism (SNP)-tagging association study of ESR1 gene variants (SNPs) in more than 55 000 breast cancer cases and controls from studies within the Breast Cancer Association Consortium (BCAC). No large risks or highly significant associations were revealed. SNP rs3020314, tagging a region of ESR1 intron 4, is associated with an increase in breast cancer susceptibility with a dominant mode of action in European populations. Carriers of the c-allele have an odds ratio (OR) of 1.05 [95% Confidence Intervals (CI) 1.02–1.09] relative to t-allele homozygotes, P = 0.004. There is significant heterogeneity between studies, P = 0.002. The increased risk appears largely confined to oestrogen receptor-positive tumour risk. The region tagged by SNP rs3020314 contains sequence that is more highly conserved across mammalian species than the rest of intron 4, and it may subtly alter the ratio of two mRNA splice forms. PMID:19126777

  3. Time-resolved Laue diffraction from protein crystals: Instrumental considerations

    International Nuclear Information System (INIS)

    Bilderback, D.H.; Cornell Univ., Ithaca, NY; Moffat, K.; Szebenyi, D.M.E.

    1984-01-01

    A serious limitation of macromolecular crystallography has been its inability to determine changes in structure on a biochemical time scale of milliseconds or less. Recently, we have shown that X-ray exposures on single crystals of macromolecules may be obtained in the millisecond time range through the use of intense, polychromatic radiation with Δlambda/lambda approx.= 0.2 derived from the Cornell High Energy Synchrotron Source, CHESS. Such radiation falling on a stationary crystal yields a Laue diffraction pattern, in which almost all Laue reflections arise from a unique set of Miller indices and where their intensities are automatically integrated over wavelength. This Laue technique requires wide band pass optics, which may be obtained by a combination of reflection and transmission mirrors, filters or layered synthetic microstructures. Time-resolved macromolecular crystallography may be achieved by several data collection schemes: 'one-shot' recording coupled to a simple streak camera, repetitive sample perturbation coupled to a detector with temporal resolution and repetitive perturbation which uses the synchrotron pulses for stroboscopic triggering and detection. These schemes are appropriate for different time scales, roughly the milli-, micro- and nanosecond regimes. It appears that time-resolved crystallography is entirely feasible, with an ultimate time resolution limited only by the length of a synchrotron light pulse, some 150 ps at CHESS. (orig.)

  4. ESR dating a quaternary travertine

    International Nuclear Information System (INIS)

    Lopez Carranza, E.; Amosse, J.; Bouchez, R.

    1987-10-01

    To study the chronology of the quarternary glaciations in the high Peruvian Andes (3.5-4.0 Km high) a number of samples of travertines was collected in the Oroya-Tarma-Huancayo region. We report, in particular, the ESR measurements realized on samples from Santa Rosa de Sacco, which contain 99% of calcite and show a line of g=2.0046 and of width 8.3G, stable, at least, until ∼ 270 deg C. Using the additive dose method to obtain the paleodose and measuring the annual dose by spectrometry gamma of high resolution we obtain for the samples, as a preliminary result, an age between 260,000 and 340,000 a. (author). 7 refs, 6 figs

  5. Time-resolved luminescence from quartz: An overview of contemporary developments and applications

    Energy Technology Data Exchange (ETDEWEB)

    Chithambo, M.L., E-mail: m.chithambo@ru.ac.za [Department of Physics and Electronics, Rhodes University, PO BOX 94, Grahamstown 6140 (South Africa); Ankjærgaard, C. [Soil Geography and Landscape Group, Wageningen University Netherlands Centre for Luminescence Dating, Droevendaalsesteeg 3, 6708 PB Wageningen, The Netherlands (Netherlands); Pagonis, V. [McDaniel College, Physics Department, Westminster, MD 21157 (United States)

    2016-01-15

    Time-resolved optical stimulation of luminescence has become established as a key method for measurement of optically stimulated luminescence from quartz, feldspar and α-Al{sub 2}O{sub 3}:C, all materials of interest in dosimetry. The aim of time-resolved optical stimulation is to separate in time the stimulation and emission of luminescence. The luminescence is stimulated from a sample using a brief light pulse and the emission monitored during stimulation in the presence of scattered stimulating light or after pulsing, over photomultiplier noise only. Although the use of the method in retrospective dosimetry has been somewhat limited, the technique has been successfully applied to study mechanisms in the processes leading up to luminescence emission. The main means for this has been the temperature dependence of the luminescence intensity as well as the luminescence lifetimes determined from time-resolved luminescence spectra. In this paper we review some key developments in theory and applications to quartz including methods of evaluating lifetimes, techniques of evaluating kinetic parameters using both the dependence of luminescence intensity and lifetime on measurement temperature, and of lifetimes on annealing temperature. We then provide an overview of some notable applications such as separation of quartz signals from a quartz–feldspar admixture and the utility of the dynamic throughput, a measure of luminescence measured as a function of the pulse width. The paper concludes with some suggestions of areas where further exploration would advance understanding of dynamics of luminescence in quartz and help address some outstanding problems in its application.

  6. ESR dosimetry below 1 Gy, in X-ray irradiated tooth enamel

    International Nuclear Information System (INIS)

    Fainstein, Carlos; Winkler, Elin

    2000-01-01

    Tooth enamel, extracted from molars, was irradiated with 66 keV X-rays, with doses up to 1 Gy. The preparation of the powder samples is described, as well as the protocol for the acquisition and processing of the spectra. The radiation induced paramagnetism is measured, at room temperature, by ESR Spectroscopy. The ESR spectra is well described considering two paramagnetic species, with magnetic moments (in units of Bohr magneton) g=2,0041, and g 1 =2,0018, g 2 =1,9972. The ESR data (peak-to-peak amplitude per mg, hpp/mg, vs dose D), for doses 0 Gy 2 =0,996) with the linear expression: [hpp/mg] = -0,2(0,4)+14,9(0,5). D [Gy]. The result supports the growing confidence in the use of this material, and method, in Retrospective Dosimetry. (author)

  7. ESR Dosimetry Below 1 Gy, in X-Ray Irradiated Tooth Enamel

    International Nuclear Information System (INIS)

    Fainstein, Carlos; Winkler, E; Dubner, D; Gisone, P; Perez, M.R; Saravi, M; Alvarez, P; Davila, F

    2000-01-01

    Tooth enamel, extracted from molars, was irradiated with 66keV X-rays, with doses up to 1Gy.The preparation of the powder samples is described, as well as the protocol for the acquisition and processing of the spectra.The radiation induced paramagnetism is measured, at room temperature, by ESR Spectroscopy.The ESR spectra is well described considering two paramagnetic species, with magnetic moments (in units of Bohr magnetons) g=2,0041, and g1=2,0018, g2=1,9972.The ESR data (peak-to-peak amplitude per mg, hpp/mg, vs dose D), for doses 0Gy 2 =0,996) with the linear expression: [hpp/mg] = -0,2( 0,4)+14,9(0,5). D [Gy].The result supports the growing confidence in the use of this material, and method, in Retrospective Dosimetry

  8. Application of ENDOR-induced electron spin resonance to the study of point defects in solids

    International Nuclear Information System (INIS)

    Niklas, J.R.; Spaeth, J.M.

    1980-01-01

    The technique of ENDOR-induced ESR (EI-ESR) is applied to the investigation of several point defects in insulating crystals. It is shown that the lineshape of the EI-ESR spectrum depends on the ENDOR line used for the experiment. The EI-ESR technique allows the separation of overlapping ESR spectra in the presence of several defects. New applications are the selection of spin states and the determination of relative signs of spin-Hamiltonian parameters, the selection of centre orientations and the assignment of nuclei in complex ENDOR spectra, and the determination of quadrupole interactions which are not resolved in the ENDOR spectrum. (author)

  9. Plasma polarization spectroscopy. Time resolved spectroscopy in soft x-ray region on recombining plasma

    International Nuclear Information System (INIS)

    Iwamae, Atsushi; Hasuo, Masahiro; Atake, Makoto; Hasegawa, Noboru; Kawachi, Tetsuya

    2007-01-01

    We present an experimental study of polarization of emission radiations from recombining plasmas generated by the interaction of 60 fs ultra-short laser pulses with a gas jet. Time-resolved spectroscopy with a temporal resolution of 5 ps with repetitive accumulation is used to follow the recombination time histories. (author)

  10. Reaction mechanism for radiation-induced degradation of poly(methyl methacrylate) as studied by ESR and ESE

    International Nuclear Information System (INIS)

    Yoshida, H.; Ichikawa, T.

    1991-01-01

    Reaction mechanism for the radiation-induced degradation of poly(methyl methacrylate) has been studied based on the ESR and electron spin echo observations of the free radicals in the polymer irradiated with γ-rays. It is indicated that the side-chain radical, -CH 2 -CCH 3 (COOC-radicalH 2 )-, is the precursor for the main-chain scission. This radical transforms into the propagating-type radical, a fingerprint of the main-chain scission, without loss of the total radical concentration. UV illumination converts the side-chain radical into the acyl-type radical, -CH 2 -CCH 3 (-C-radical=O)-, which thermally transforms into the propagating-type radical. The radical of the type, -CH 2 -C-radicalCH 3 -CH 2 -, is suggested as a common, immediate precursor for the main-chain scission with and without the UV illumination, though it has not been detected because of its short life-time. (author) 7 refs.; 2 figs

  11. Time-Resolved Fluorescent Immunochromatography of Aflatoxin B1 in Soybean Sauce: A Rapid and Sensitive Quantitative Analysis.

    Science.gov (United States)

    Wang, Du; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Zhang, Wen

    2016-07-14

    Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatography. The dynamic range of a competitive and portable immunoassay was 0.3-10.0 µg·kg(-1), with a limit of detection (LOD) of 0.1 µg·kg(-1) and recoveries of 87.2%-114.3%, within 10 min. The results showed good correlation (R² > 0.99) between time-resolved fluorescent immunochromatographic strip test and high performance liquid chromatography (HPLC). Soybean sauce samples analyzed using time-resolved fluorescent immunochromatographic strip test revealed that 64.2% of samples contained aflatoxin B1 at levels ranging from 0.31 to 12.5 µg·kg(-1). The strip test is a rapid, sensitive, quantitative, and cost-effective on-site screening technique in food safety analysis.

  12. Time - resolved thermography at Tokamak T-10

    International Nuclear Information System (INIS)

    Grunow, C.; Guenther, K.; Lingertat, J.; Chicherov, V.M.; Evstigneev, S.A.; Zvonkov, S.N.

    1987-01-01

    Thermographic experiments were performed at T-10 tokamak to investigate the thermic coupling of plasma and the limiter. The limiter is an internal equipment of the vacuum vessel of tokamak-type fusion devices and the interaction of plasma with limiter results a high thermal load of limiter for short time. In according to improve the limiter design the temperature distribution on the limiter surface was measured by a time-resolved thermographic method. Typical isotherms and temperature increment curves are presented. This measurement can be used as a systematic plasma diagnostic method because the limiter is installed in the tokamak whereas special additional probes often disturb the plasma discharge. (D.Gy.) 3 refs.; 7 figs

  13. Time Resolved X-Ray Scattering of molecules in Solution

    DEFF Research Database (Denmark)

    Brandt van Driel, Tim

    The dissertation describes the use of Time-Resolved X-ray Diffuse Scattering (TR-XDS) to study photo-induced structural changes in molecules in solution. The application of the technique is exemplified with experiments on two bimetallic molecules. The main focus is on the data-flow and process......)42+ obtained at European Synchrotron Radiation Facility (ESRF) are presented to exemplify TR-XDS at synchrotrons. Similarly, measurements on Ir2(dimen)42+ are used to show the XFEL data-flow and how it deviates from the prior. A method to identify and account for systematic fluctuations...

  14. Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences

    International Nuclear Information System (INIS)

    Fink, C.; Puderbach, M.; Zaporozhan, J.; Plathow, C.; Kauczor, H.-U.; Ley, S.

    2005-01-01

    The aim of this study was to evaluate the image quality of time-resolved echo-shared parallel MRA of the lung. The pulmonary vasculature of nine patients (seven females, two males; median age: 44 years) with pulmonary disease was examined using a time-resolved MRA sequence combining echo sharing with parallel imaging (time-resolved echo-shared angiography technique, or TREAT). The sharpness of the vessel borders, conspicuousness of peripheral lung vessels, artifact level, and overall image quality of TREAT was assessed independently by four readers in a side-by-side comparison with non-echo-shared time-resolved parallel MRA data (pMRA) previously acquired in the same patients. Furthermore, the SNR of pulmonary arteries (PA) and veins (PV) achieved with both pulse sequences was compared. The mean voxel size of TREAT MRA was decreased by 24% compared with the non-echo-shared MRA. Regarding the sharpness of the vessel borders, conspicuousness of peripheral lung vessels, and overall image quality the TREAT sequence was rated superior in 75-76% of all cases. If the TREAT images were preferred over the pMRA images, the advantage was rated as major in 61-71% of all cases. The level of artifacts was not increased with the TREAT sequence. The mean interobserver agreement for all categories ranged between fair (artifact level) and good (overall image quality). The maximum SNR of TREAT did not differ from non-echo-shared parallel MRA (PA: TREAT: 273±45; pMRA: 280±71; PV: TREAT: 273±33; pMRA: 258±62). TREAT achieves a higher spatial resolution than non-echo-shared parallel MRA which is also perceived as an improved image quality. (orig.)

  15. Charge transport in nanostructured materials for solar energy conversion studied by time-resolved terahertz spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Němec, Hynek; Kužel, Petr; Sundström, V.

    2010-01-01

    Roč. 215, 2-3 (2010), s. 123-139 ISSN 1010-6030 R&D Projects: GA ČR(CZ) GP202/09/P099; GA AV ČR(CZ) IAA100100902; GA MŠk LC512 Institutional research plan: CEZ:AV0Z10100520 Keywords : time-resolved terahertz spectroscopy * ultrafast dynamics * bulk heterojunction * semiconductor nanostructures * transport * mobility Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.243, year: 2010

  16. Studying the potential of point detectors in time-resolved dose verification of dynamic radiotherapy

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, C. F.; Andersen, Claus E.

    2015-01-01

    based on fiber-coupled plastic scintillator detectors was evaluated and compared with a Farmer-type ionization chamber and a small-volume ionization chamber. An important feature of scintillator detectors is that the sensitive volume of the detector can easily be scaled, and five scintillator detectors......-volume ionization chamber and the smallest scintillators. The time-resolved RapidArc dose profiles revealed volume-dependent discrepancies between scintillator and ionization chamber response, which confirmed that correction factors for ionization chambers in high temporal and spatial dose gradients are dominated...

  17. Time-resolved fluorescence quenching studies of sodium lauryl ether sulfate micelles

    International Nuclear Information System (INIS)

    Friedrich, Leidi C.; Silva, Volnir O.; Quina, Frank H.; Moreira Junior, Paulo F.; Tcacenco, Celize M.

    2013-01-01

    Aggregation numbers (N Ag ) of micelles of the commercial anionic detergent sodium lauryl ether sulfate (SLES), with an average of two ethylene oxide subunits, were determined at 30 and 40 deg C by the time-resolved fluorescence quenching method with pyrene as the fluorescent probe and the N-hexadecylpyridinium ion as the quencher. The added-salt dependent growth of SLES micelles (γ = 0.11-0.15, where γ is the slope of a plot of log aggregation number vs. log [Y aq ] and [Y aq ] is the sodium counterion concentration free in the intermicellar aqueous phase) is found to be significantly lower than that of sodium alkyl sulfate micelles (γ ca. 0.25), a difference attributed to the larger headgroup size of SLES. The I 1 /I 3 vibronic intensity ratio and the rate constant for intramicellar quenching of pyrene show that the pyrene solubilization microenvironment and the intramicellar microviscosity are insensitive to micelle size or the presence of added salt. (author)

  18. Time-resolved fluorescence quenching studies of sodium lauryl ether sulfate micelles

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Leidi C.; Silva, Volnir O.; Quina, Frank H., E-mail: quina@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Quimica; Moreira Junior, Paulo F. [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Escola Politecnica. Departamento de Engenharia Quimica; Tcacenco, Celize M. [Fundacao Instituto de Ensino para Osasco (FIEO/UNIFIEO), SP (Brazil). Centro Universitario FIEO. Centro de Estudos Quimicos

    2013-02-15

    Aggregation numbers (N{sub Ag}) of micelles of the commercial anionic detergent sodium lauryl ether sulfate (SLES), with an average of two ethylene oxide subunits, were determined at 30 and 40 deg C by the time-resolved fluorescence quenching method with pyrene as the fluorescent probe and the N-hexadecylpyridinium ion as the quencher. The added-salt dependent growth of SLES micelles ({gamma} = 0.11-0.15, where {gamma} is the slope of a plot of log aggregation number vs. log [Y{sub aq}] and [Y{sub aq}] is the sodium counterion concentration free in the intermicellar aqueous phase) is found to be significantly lower than that of sodium alkyl sulfate micelles ({gamma} ca. 0.25), a difference attributed to the larger headgroup size of SLES. The I{sub 1}/I{sub 3} vibronic intensity ratio and the rate constant for intramicellar quenching of pyrene show that the pyrene solubilization microenvironment and the intramicellar microviscosity are insensitive to micelle size or the presence of added salt. (author)

  19. ESR investigation of L-α-alanine and sucrose radicals produced by heavy-ion irradiation

    International Nuclear Information System (INIS)

    Nakagawa, K.; Sato, Y.

    2005-01-01

    We investigated sucrose and L-α-alanine radicals produced by heavy (particle) ion irradiation with various LETs (linear energy transfer). The impact of the heavy ions on the samples produced stable free radicals, which were analyzed by ESR (electron spin resonance). Identical spectra were measured after one year. The obtained spectral patterns were the same as those for helium (He), carbon (C), and neon (Ne) ions irradiation. The absorbed dose dependences for the irradiated sucrose and alanine samples were examined. The ESR response has a linear relation with the absorbed dose. The ESR response at 60 Gy was slightly lower than a linear line for sucrose; however, the response showed good linearity for the alanine. In addition, the total spin concentration obtained by heavy-ion irradiation correlated logarithmically with the LET. Qualitative ESR analyse showed that the production of sucrose and alanine radicals depended on both different particle irradiation and the LET under the same dose. Thus, the present ESR results imply that sucrose together with L-α-alanine can be used to monitor LET as well as the number of ionizing particle for the production of stable free radicals. (author)

  20. Particle tracking during Ostwald ripening using time-resolved laboratory X-ray microtomography

    Energy Technology Data Exchange (ETDEWEB)

    Werz, T., E-mail: thomas.werz@uni-ulm.de [Ulm University, Institute of Micro and Nanomaterials, Albert-Einstein-Allee 47, 89081 (Germany); Baumann, M. [Ulm University, Institute of Micro and Nanomaterials, Albert-Einstein-Allee 47, 89081 (Germany); Wolfram, U. [Ulm University, Institute of Orthopaedic Research and Biomechanics, Helmholtzstrasse 14, 89081 (Germany); Krill, C.E. [Ulm University, Institute of Micro and Nanomaterials, Albert-Einstein-Allee 47, 89081 (Germany)

    2014-04-01

    Laboratory X-ray microtomography is investigated as a method for obtaining time-resolved images of microstructural coarsening of the semisolid state of Al–5 wt.% Cu samples during Ostwald ripening. Owing to the 3D imaging capability of tomography, this technique uniquely provides access to the growth rates of individual particles, thereby not only allowing a statistical characterization of coarsening—as has long been possible by conventional metallography—but also enabling quantification of the influence of local environment on particle boundary migration. The latter information is crucial to understanding growth kinetics during Ostwald ripening at high volume fractions of the coarsening phase. Automated image processing and segmentation routines were developed to close gaps in the network of particle boundaries and to track individual particles from one annealing step to the next. The particle tracking success rate places an upper bound of only a few percent on the likelihood of segmentation errors for any given particle. The accuracy of particle size trajectories extracted from the time-resolved tomographic reconstructions is correspondingly high. Statistically averaged coarsening data and individual particle growth rates are in excellent agreement with the results of prior experimental studies and with computer simulations of Ostwald ripening. - Highlights: • Ostwald ripening in Al–5 wt.% Cu measured by laboratory X-ray microtomography • Time-resolved measurement of individual particle growth • Automated segmentation routines developed to close gaps in particle boundary network • Particle growth/shrinkage rates deviate from LSW model prediction.

  1. Time-resolved X-ray photoelectron spectroscopy techniques for the study of interfacial charge dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Neppl, Stefan, E-mail: sneppl@lbl.gov; Gessner, Oliver

    2015-04-15

    Highlights: • Ultrafast interfacial charge transfer is probed with atomic site specificity. • Femtosecond X-ray photoelectron spectroscopy using a free electron laser. • Efficient and flexible picosecond X-ray photoelectron pump–probe scheme using synchrotron radiation. - Abstract: X-ray photoelectron spectroscopy (XPS) is one of the most powerful techniques to quantitatively analyze the chemical composition and electronic structure of surfaces and interfaces in a non-destructive fashion. Extending this technique into the time domain has the exciting potential to shed new light on electronic and chemical dynamics at surfaces by revealing transient charge configurations with element- and site-specificity. Here, we describe prospects and challenges that are associated with the implementation of picosecond and femtosecond time-resolved X-ray photoelectron spectroscopy at third-generation synchrotrons and X-ray free-electron lasers, respectively. In particular, we discuss a series of laser-pump/X-ray-probe photoemission experiments performed on semiconductor surfaces, molecule-semiconductor interfaces, and films of semiconductor nanoparticles that demonstrate the high sensitivity of time-resolved XPS to light-induced charge carrier generation, diffusion and recombination within the space charge layers of these materials. Employing the showcase example of photo-induced electronic dynamics in a dye-sensitized semiconductor system, we highlight the unique possibility to probe heterogeneous charge transfer dynamics from both sides of an interface, i.e., from the perspective of the molecular electron donor and the semiconductor acceptor, simultaneously. Such capabilities will be crucial to improve our microscopic understanding of interfacial charge redistribution and associated chemical dynamics, which are at the heart of emerging energy conversion, solar fuel generation, and energy storage technologies.

  2. Experimental studies of the propagation of electrostatic ion perturbations by time-resolved laser-induced fluorescence

    International Nuclear Information System (INIS)

    Bachet, G.; Skiff, F.; Doveil, F.; Stern, R.A.

    2001-01-01

    Effects induced by the propagation of several kinds of electrostatic perturbation in a low-density collisionless argon plasma are observed with space, time, and velocity-resolved laser-induced fluorescence (LIF). The propagation of strong self-organized ion structures is observed and the associated electric field is determined. Snap shots of the ion phase space with a time resolution of 2 μs can be reconstructed from the experimental data. All the terms of the kinetic equation can also be determined from the data. A one-dimensional (1D) numerical simulation reproduces qualitatively the experimentally observed ion phase space behavior

  3. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  4. ESR dating of glacial tills of Baishuihe river on the southern slope of Lenglongling in the eastern part of Qilian Mountains

    International Nuclear Information System (INIS)

    Zhao Jingdong; Zhou Shangzhe; Shi Zhengtao; Zhang Shiqiang; Cui Jianxin; Xu Liubing; Ye Yuguang

    2001-01-01

    Baishuihe River is a tributary of Datong River, located on the southern slope of Lenglongling in the eastern part of the Qilian Mountains. An integral end till remains at the entrance of the valley. There is a push moraine in the till section. Three samples were derived from this section. Two samples were collected at the front of the push moraine and another sample (near the push moraine) collected from the rear of it, ESR ages were 73.0 ka, 55.8 ka, 36.7 ka respectively. The ESR ages being consistent with the relationship of deposits. The ages before the push moraine were correlated to the deep-sea oxygen isotope stage 4 within 10% deviation. Based on them, the authors could determine the till before the push moraine were formed in the early period of Last Glaciation. Comparing the ESR age of LS-5 with the results of previous 14 C, the authors found that the ESR age was older. Through the error correction, the authors concluded: the existing push moraine distorted the till around it, mixing the super-glacial till, englacial till and subglacial till together. The authors considered: the main reason influencing the ESR age was that the englacial till and the subglacial till were not exposed completely before they deposited. Although the result of LS-5 was older than the previous 14 C, combining the ESR age and the relationship of deposit and the existing 14 C ages, the authors inferred that the rear of the push moraine was deposited in the later period of the last glaciation and was correlated to the deep-sea oxygen isotope stage 2. At the same time, the conclusion once again proved the previous scholars' conclusion. This shows the ESR technique may be applied to glacial till dating

  5. Distribution of free radical products among the bases of x-irradiated DNA model systems: an ESR study

    International Nuclear Information System (INIS)

    Spalletta, R.A.

    1984-01-01

    Exposure of solid state DNA to ionizing radiation results in an ESR spectrum that has been attributed to a nonstoichiometric distribution of free radicals among the bases. At low temperatures radical cations appear to be stabilized on the purines while radical anions are stabilized on the pyrimidines. This distribution could arise from at least two different mechanisms. The first, charge transfer, involves the transfer of electrons and/or holes between stacked bases. In the second, saturation asymmetry, the free radical distribution arises from differences in the dose saturation characteristics of individual bases. The present study addresses the relative importance of charge transfer versus saturation asymmetry in the production of these population differences. Radicals formed by dissolving irradiated polycrystalline pyrimidines in aqueous solutions containing NtB or PBN spin traps were analyzed using ESR. The relative importance of the two free radical production and distribution mechanisms was assessed using DNA model systems. Saturation asymmetry plays a significant role in determining the free radical population while charge transfer was unambiguously observed in only one, the complex of dAMP and TMP. The results demonstrate that any quantitative analysis of charge transfer must take saturation asymmetry into account

  6. Time Resolved PIV for Space-Time Correlations in Hot Jets

    Science.gov (United States)

    Wernet, Mark P.

    2007-01-01

    Temporally Resolved Particle Image Velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows -- a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered 6 nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centered along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space-time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number

  7. Retrospective Dosimetry: Dose Analysis From Tooth Enamel Using Electron Spin Resonance (ESR)

    International Nuclear Information System (INIS)

    Mohd Rodzi Ali; Rahimah Abdul Rahim; Noraisyah Yusof; Syed Asraf Fahlawi Wafa Syed Mohd Ghazi; Juliana Mahamad Napiah; Yahaya Talib; Rehir Dahalan

    2014-01-01

    The radiation dose should be accurately measured in order to relate its effect to the cells. The assessment of dose usually performed using biological dosimetry techniques. However, the reduction of lymphocytes (white blood cells) after the time period results in inaccuracy of dose measurement. An alternative method used is the application of Electron Spin Resonance (ESR) using tooth enamel. In this study, tooth enamels were evaluated and used to measure the individual absorbed dose from the background. The basic tooth features that would affect dose measurement were discussed. The results show this technique is capable and effective for retrospective dose measurement and useful for the study of radiation effect to human. (author)

  8. The influence of non-radiation induced ESR background signal from paraffin-alanine probes for dosimetry in the radiotherapy dose range

    International Nuclear Information System (INIS)

    Wieser, A.; Lettau, C.; Fill, U.; Regulla, D.F.

    1993-01-01

    The yield of radicals induced by ionizing radiation in the amino acid alanine and its quantification by ESR spectroscopy has proven excellent reproducibility. Those radicals trapped in the crystal lattice are prevented from recombination providing a thermally very stable system. This allows alanine to be applied as a transfer dosemeter. With paraffin-alanine probes ESR dosimetry can be performed with a standard deviation of ± 0.5% in the dose range from 20 Gy up to 100 kGy. At 1 Gy dose level the error increases to ± 6%. This dose level is three orders of magnitude higher than the calculated detection threshold for alanine with modern X-band ESR spectrometers. It was found that the poor standard deviation at the 1 Gy dose level, is not mainly produced by a bad signal-to-noise ratio but by a variable non-radiation induced ESR background signal from the alanine probes within a batch. In the present study the main sources of error for ESR dosimetry in the dose range below 20 Gy were analyzed. The influences of the production process, UV light and humidity upon the ESR background signal from paraffin-alanine probes were investigated. Measurements are shown indicating a second stable structure of the alanine radical at room temperature. (author)

  9. Dating of aragonite and dolomite from Devil's cave - SP, by dosimetric thermoluminescent method (DTL) and ESR

    International Nuclear Information System (INIS)

    Tatumi, S.H.

    1987-01-01

    We have investigated TL (Thermoluminescence) and ESR (electron spin resonance) properties of aragonite and dolomite found at ''Caverna do Diabo (Devil's cave)'' in the state of Sao Paulo to determine the ages of these geological materials. The aragonite, which is not a thermoluminescent material, shows one ESR signal whit g = 2.003. We obtained the age of 1.1 x 10 5 years and the growth rate of 1 μ m/year by the sample calibration with additional Y irradiation. The dolomite gives a TL glow curve with three distinct peaks at 261, 334 and 395 0 C. We found that the fit for the TL glow curve to second-order kinetics can be considerered as very acceptable. Using the second TL peak we obtained the age of 9.4 x 10 5 years and the compatible values of the activation energy (1.90 ± 0,07 eV) by the following methods: Hyperbolic heating, isothermal decay and fractional glow technique. We observed many ESR absorption signals in the dolomite. Three principal signal com g = 2.002, 2.003 and 2.005 were studied. We found that the first and second ESR signals were atributed to the CO 2 - and/or CO 3 3- centers and the last to the CO 3 - centers, and observed that the first ESR signal might related with the second TL peak and the TL sensitivity were associated with the concentration of Mn 2+ [pt

  10. Superconductivity and magnetism in the oxypnictides: high field ESR and {mu}SR studies of (La,Gd)FeAsO{sub 1-x}F{sub x} compounds

    Energy Technology Data Exchange (ETDEWEB)

    Muranyi, Ferenc [Physics Institute, University of Zuerich (Switzerland); IFW Dresden (Germany); Alfonsov, Alexey; Kataev, Vladislav; Koehler, Anke; Werner, Jochen; Behr, Guenter; Leps, Norman; Klingeler, Ruediger; Kondrat, Agnieszka; Hess, Christian; Buechner, Bernd [IFW Dresden (Germany); Khasanov, Rustem; Luetkens, Hubertus [Paul Scherrer Institut, Villigen PSI (Switzerland); Klaus, Hans-Henning [IFP, TU Dresden (Germany)

    2009-07-01

    The discovery of a new class of superconducting materials, ReFeAsO{sub 1-x}F{sub x}, stirred up the scientific community. Here we report the Gd{sup 3+} high field ESR study of differently doped (La,Gd)FeAsO{sub 1-x}F{sub x} compounds. In lightly Gd-doped LaFeAsO samples the SDW transition yields line-broadening at the transition temperature, the SDW transition is then suppressed upon F-doping. In the dense compound, GdFeAsO, with SDW transition around 140 K, the Gd-ESR was also studied. With 15% F-doping superconductivity appears at {proportional_to} 21 K. The SDW and SC transitions are clearly seen in ESR and in {mu} SR as well. Surprisingly the reminiscence of the SDW transition of the undoped material (GdFeAsO) was identified in the doped (15% F) compound at lower temperature ({proportional_to} 80 K). This indicates the importance of the the interplay between superconductivity and magnetism in oxypnictides.

  11. Time-resolved X-ray transmission microscopy on magnetic microstructures

    International Nuclear Information System (INIS)

    Puzic, Aleksandar

    2007-01-01

    Three excitation schemes were designed for stroboscopic imaging of magnetization dynamics with time-resolved magnetic transmission X-ray microscopy (TR-MTXM). These techniques were implemented into two types of X-ray microscopes, namely the imaging transmission X-ray microscope (ITXM) and the scanning transmission X-ray microscope (STXM), both installed at the electron storage ring of the Advanced Light Source in Berkeley, USA. Circular diffraction gratings (Fresnel zone plates) used in both microscopes as focusing and imaging elements presently allow for lateral resolution down to 30 nm. Magnetic imaging is performed by using the X-ray magnetic circular dichroism (XMCD) as element specific contrast mechanism. The developed methods have been successfully applied to the experimental investigation of magnetization dynamics in ferromagnetic microstructures. A temporal resolution well below 100 ps was achieved. A conventional pump-probe technique was implemented first. The dynamic response of the magnetization excited by a broadband pulsed magnetic field was imaged spatially resolved using focused X-ray flashes. As a complementary method, the spatially resolved ferromagnetic resonance (SR-FMR) technique was developed for experimental study of magnetization dynamics in the frequency domain. As a third excitation mode, the burst excitation was implemented. The performance and efficiency of the developed methods have been demonstrated by imaging the local magnetization dynamics in laterally patterned ferromagnetic thin-film elements and three-layer stacks. The existence of multiple eigenmodes in the excitation spectra of ferromagnetic microstructures has been verified by using the pump-probe technique. Magnetostatic spin waves were selectively excited and detected with a time resolution of 50 ps using the SR-FMR technique. Thorough analysis of 20 in most cases independently prepared samples has verified that vortices which exhibit a low-amplitude switching of their core

  12. Cooling history of the Valles Caldera, New Mexico using ESR dating method

    International Nuclear Information System (INIS)

    Ogoh, K.; Toyoda, S.; Ikeda, S.; Ikeya, M.; Goff, F.

    1993-01-01

    ESR dating was made at the Valles caldera by using the Al center and Ti center in quartz grains separated from the layers of the Valles Rhyolite. Obtained ESR ages were much younger than those by other methods (fission track and 39 Ar- 40 Ar). A reported thermal event of about 10-40 ka ago might explain the difference between the above ages. (author)

  13. The RATIO method for time-resolved Laue crystallography

    International Nuclear Information System (INIS)

    Coppens, P.; Pitak, M.; Gembicky, M.; Messerschmidt, M.; Scheins, S.; Benedict, J.; Adachi, S.-I.; Sato, T.; Nozawa, S.; Ichiyanagi, K.; Chollet, M.; Koshihara, S.-Y.

    2009-01-01

    A RATIO method for analysis of intensity changes in time-resolved pump-probe Laue diffraction experiments is described. The method eliminates the need for scaling the data with a wavelength curve representing the spectral distribution of the source and removes the effect of possible anisotropic absorption. It does not require relative scaling of series of frames and removes errors due to all but very short term fluctuations in the synchrotron beam.

  14. The effect of irradiation dose and storage time on the ESR signal in the cuticle of different components of the exoskeleton of Norway lobster (Nephrops norvegicus)

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, E.M. (Queen' s Univ., Belfast, Northern Ireland (United Kingdom)); Stevenson, M.H. (Department of Agriculture for Northern Ireland (United Kingdom). Food and Agricultural Chemistry Research Div. Queen' s Univ., Belfast, Northern Ireland (United Kingdom)); Gray, R. (Department for Agriculture for Northern Ireland (United Kingdom). Food and Agricultural Chemistry Research Div.)

    This paper examines the potential of ESR spectroscopy too determine if Norway lobsters have been irradiated. Ninety samples, each containing 3 whole Norway lobsters, were prepared, thirty were used as controls while the remaining sixty were given irradiation doses of approximately either 1 or 3 kGy. Following irradiation the samples were stored at 1[sup o]C for 0, 7, 14, 21 or 28 d. After each storage period the cuticle of the tail, carapace, claws and walking legs was removed, freeze-dried and ground prior to analysis using ESR spectroscopy. The control spectra were subtracted from their respective irradiated spectra thereby leaving the radiation-induced signal. Peak heights of the signals were measured. The ESR signals derived from the different components of the exoskeleton were similar in shape and varied only in their intensities. The claw samples gave the most intense signal while that from the walking legs was the weakest. There was a significant decay in the signal intensity over the storage period with the signal derived from cuticle of the claws showing the greatest diminution (44%) and that of the tail the least (17%). The signal intensities of the walking legs and carapace decreased by 22% and 30% respectively. In conclusion ESR spectroscopy is a useful technique for the qualitative detection of irradiated Norway lobster and shows considerable potential for quantification of dose received. (author).

  15. The effect of irradiation dose and storage time on the ESR signal in the cuticle of different components of the exoskeleton of Norway lobster (Nephrops norvegicus)

    International Nuclear Information System (INIS)

    Stewart, E.M.; Stevenson, M.H.; Gray, R.

    1993-01-01

    This paper examines the potential of ESR spectroscopy too determine if Norway lobsters have been irradiated. Ninety samples, each containing 3 whole Norway lobsters, were prepared, thirty were used as controls while the remaining sixty were given irradiation doses of approximately either 1 or 3 kGy. Following irradiation the samples were stored at 1 o C for 0, 7, 14, 21 or 28 d. After each storage period the cuticle of the tail, carapace, claws and walking legs was removed, freeze-dried and ground prior to analysis using ESR spectroscopy. The control spectra were subtracted from their respective irradiated spectra thereby leaving the radiation-induced signal. Peak heights of the signals were measured. The ESR signals derived from the different components of the exoskeleton were similar in shape and varied only in their intensities. The claw samples gave the most intense signal while that from the walking legs was the weakest. There was a significant decay in the signal intensity over the storage period with the signal derived from cuticle of the claws showing the greatest diminution (44%) and that of the tail the least (17%). The signal intensities of the walking legs and carapace decreased by 22% and 30% respectively. In conclusion ESR spectroscopy is a useful technique for the qualitative detection of irradiated Norway lobster and shows considerable potential for quantification of dose received. (author)

  16. Variability of electron spin resonance (ESR) signal of γ -irradiated starches

    International Nuclear Information System (INIS)

    Silva, Gilberto D.; Rodrigues Junior, Orlando; Mastro, Nelida L. del

    2017-01-01

    Food preservation is one of the practical applications of radiation processing of materials. Starch is an abundant and cheap nutritious biopolymer and also is the material for appropriate food systems and for technical industries. Starch granules are partially crystalline structures composed mainly of two types of starch: amylose, an essentially linear polymer, and amylopectin, with 3-44% of branch points. Electron spin resonance (ESR) spectroscopy is a very powerful and sensitive method for the characterization of the electronic structures of materials with unpaired electrons. The aim of the present work was to monitor the disappearance of the short life and long-life free radicals formed during γ-irradiation of 3 different starches. Corn, potato and fermented cassava starches were irradiated in a "6"0Co source Gammacell 220 with 20 kGy, dose rate around 1 kGy h"-"1. EPR spectra were obtained at room temperature using a Bruker EMX plus model, X band equipment. The main type of ESR signal from irradiated starch is a singlet with a g-value of about 2.0. The fading of ESR signals was followed for 350 hours, and presents differences among the different starch type reflecting differences in molecular arrangements of starch crystalline and amorphous fractions, although ESR spectra seemed to be common for all starches. (author)

  17. Variability of electron spin resonance (ESR) signal of γ -irradiated starches

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Gilberto D.; Rodrigues Junior, Orlando; Mastro, Nelida L. del, E-mail: nlmastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Food preservation is one of the practical applications of radiation processing of materials. Starch is an abundant and cheap nutritious biopolymer and also is the material for appropriate food systems and for technical industries. Starch granules are partially crystalline structures composed mainly of two types of starch: amylose, an essentially linear polymer, and amylopectin, with 3-44% of branch points. Electron spin resonance (ESR) spectroscopy is a very powerful and sensitive method for the characterization of the electronic structures of materials with unpaired electrons. The aim of the present work was to monitor the disappearance of the short life and long-life free radicals formed during γ-irradiation of 3 different starches. Corn, potato and fermented cassava starches were irradiated in a {sup 60}Co source Gammacell 220 with 20 kGy, dose rate around 1 kGy h{sup -1}. EPR spectra were obtained at room temperature using a Bruker EMX plus model, X band equipment. The main type of ESR signal from irradiated starch is a singlet with a g-value of about 2.0. The fading of ESR signals was followed for 350 hours, and presents differences among the different starch type reflecting differences in molecular arrangements of starch crystalline and amorphous fractions, although ESR spectra seemed to be common for all starches. (author)

  18. Uses of polymer-alanine film/ESR dosimeters in dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Xie Liqing; Zhang Yinfeng; Dai Jinxian; Lu Ting; Chen Ruyi; Yang Hua

    1993-01-01

    Alanine ESR dosimetry is a reliable method, used in a various fields of ionizing radiation. The polymer-alanine film/ESR dosimeters of 0.3 -0.4 mm thickness were prepared and their dosimetric properties were studied for 60 Co γ photons and 3 - 5 MeV electrons in the dose range from 20 Gy to 100 kGy. The results show that under normal conditions the alanine calibration curves are linear in the dose range from 100 Gy to 10kGy. The dose profiles at the electron radiation field were measured with the film alanine dosimeters. The polymer-alanine film dosimeters were used for ion implantation of 400 keV ion implantor. Their dose response and energy dependence were investigated initially. (Author)

  19. Photolysis of Br2 in CCl4 studied by time-resolved X-ray scattering.

    Science.gov (United States)

    Kong, Qingyu; Lee, Jae Hyuk; Lo Russo, Manuela; Kim, Tae Kyu; Lorenc, Maciej; Cammarata, Marco; Bratos, Savo; Buslaps, Thomas; Honkimaki, Veijo; Ihee, Hyotcherl; Wulff, Michael

    2010-03-01

    A time-resolved X-ray solution scattering study of bromine molecules in CCl(4) is presented as an example of how to track atomic motions in a simple chemical reaction. The structures of the photoproducts are tracked during the recombination process, geminate and non-geminate, from 100 ps to 10 micros after dissociation. The relaxation of hot Br(2)(*) molecules heats the solvent. At early times, from 0.1 to 10 ns, an adiabatic temperature rise is observed, which leads to a pressure gradient that forces the sample to expand. The expansion starts after about 10 ns with the laser beam sizes used here. When thermal artefacts are removed by suitable scaling of the transient solvent response, the excited-state solute structures can be obtained with high fidelity. The analysis shows that 30% of Br(2)(*) molecules recombine directly along the X potential, 60% are trapped in the A/A' state with a lifetime of 5.5 ns, and 10% recombine non-geminately via diffusive motion in about 25 ns. The Br-Br distance distribution in the A/A' state peaks at 3.0 A.

  20. Dispersion of sulphur in the northern hemisphere. A study with a 3-dimensional time-resolved model

    Energy Technology Data Exchange (ETDEWEB)

    Tarrason, L

    1996-12-31

    This thesis on atmospheric dispersion of sulphur presents a calculation of intercontinental transport of oxidized sulphur and allocates different contributions to sulphur background levels over Europe. It is found that a significant fraction of anthropogenic sulphur (AS) is transported out of continental boundaries thus affecting the background levels over major parts of the northern hemisphere. Over Europe, the contribution of AS from North America is similar in amount to that of Asian AS and natural sources from the North Atlantic Ocean. Although the yearly contribution of intercontinental transport to deposition of sulphur over Europe is quite small, it can be much more important over certain areas and seasons and is comparable to the contributions from individual European countries. The calculations are based on a three-dimensional Eulerian time-resolved model that describes sulphur dispersion in the atmosphere in connection with large-scale synoptic flows and agree well with observations. The thesis emphasizes the role of synoptic scale atmospheric motions in determining intercontinental transport of sulphur. It indicates the need to resolve individual cyclones and anticyclones in order to describe the dispersion and distribution of atmospheric sulphur in the northern hemisphere and stresses the value of comparing model calculations with observations, both in atmospheric chemistry studies and in climate applications. 260 refs., 50 figs., 17 tabs.

  1. Dispersion of sulphur in the northern hemisphere. A study with a 3-dimensional time-resolved model

    Energy Technology Data Exchange (ETDEWEB)

    Tarrason, L.

    1995-12-31

    This thesis on atmospheric dispersion of sulphur presents a calculation of intercontinental transport of oxidized sulphur and allocates different contributions to sulphur background levels over Europe. It is found that a significant fraction of anthropogenic sulphur (AS) is transported out of continental boundaries thus affecting the background levels over major parts of the northern hemisphere. Over Europe, the contribution of AS from North America is similar in amount to that of Asian AS and natural sources from the North Atlantic Ocean. Although the yearly contribution of intercontinental transport to deposition of sulphur over Europe is quite small, it can be much more important over certain areas and seasons and is comparable to the contributions from individual European countries. The calculations are based on a three-dimensional Eulerian time-resolved model that describes sulphur dispersion in the atmosphere in connection with large-scale synoptic flows and agree well with observations. The thesis emphasizes the role of synoptic scale atmospheric motions in determining intercontinental transport of sulphur. It indicates the need to resolve individual cyclones and anticyclones in order to describe the dispersion and distribution of atmospheric sulphur in the northern hemisphere and stresses the value of comparing model calculations with observations, both in atmospheric chemistry studies and in climate applications. 260 refs., 50 figs., 17 tabs.

  2. On the theory of time-resolved x-ray diffraction

    DEFF Research Database (Denmark)

    Henriksen, Niels Engholm; Møller, Klaus Braagaard

    2008-01-01

    We derive the basic theoretical formulation for X-ray diffraction with pulsed fields, using a fully quantized description of light and matter. Relevant time scales are discussed for coherent as well as incoherent X-ray pulses, and we provide expressions to be used for calculation...... of the experimental diffraction signal for both types of X-ray sources. We present a simple analysis of time-resolved X-ray scattering for direct bond breaking in diatomic molecules. This essentially analytical approach highlights the relation between the signal and the time-dependent quantum distribution...

  3. The nitrogen acceptor in 2H-Polytype synthetic MoS2. Frequency and temperature dependent ESR analysis

    International Nuclear Information System (INIS)

    Schoenaers, Ben; Stesmans, Andre; Afanas'ev, Valery V.

    2017-01-01

    In extending on recent electron spin resonance (ESR) work which has revealed the N acceptor (N substituting for S site) in 2H-polytype bulk synthetic MoS 2 , the dopant is extensively analyzed in terms of its frequency, temperature (T), and magnetic field B angular dependent ESR spectral characteristics. For B parallel c-axis, the multi-frequency analysis confirms the ESR spectrum as being composed of a 14 N hyperfine (hf) triplet with hf splitting constant A parallel = 14.7 ± 0.2 G (B parallel c-axis) and making up ∼74% of the total spectrum intensity, superimposed on a central line centered at about equal g-value [g parallel = 2.032(2)]. The presence of the latter signal, points to some non-uniformity in dopant distribution, that is, clustering, with about ∼26% of the total N response not originating from N incorporated in the preferred ''isolated'' dopant configuration. Angular dependent measurements reveal distinct anisotropy of the hf matrix, whereas ESR probing over a wide T-range exposes drastic signal broadening with increasing T above ∼150 K. Detailed study of the N acceptor signal intensity versus T at Q-band reveals an activation energy E a = 50 ± 10 meV, herewith consolidating the value reported initially. Besides unveiling the S-site substitutional N impurity as an appropriate p-type dopant for MoS 2 , the total of the ESR work establishes a basic frame of the N acceptor ESR characteristics, giving way for further in-depth theoretical perusal. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. The influence of surface modification, coating agents and pH value of aqueous solutions on physical properties of magnetite nanoparticles investigated by ESR method

    Energy Technology Data Exchange (ETDEWEB)

    Dobosz, Bernadeta, E-mail: benia@amu.edu.pl [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Krzyminiewski, Ryszard [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Kurczewska, Joanna; Schroeder, Grzegorz [Faculty of Chemistry, Adam Mickiewicz University, Umultowska 89B, 61-614 Poznań (Poland)

    2017-05-01

    The article presents the results of electron spin resonance (ESR) studies for aqueous solutions of functionalized superparamagnetic iron(II,III) oxide nanoparticles. The samples studied differed in type of organic ligands at the magnetite surface, type of coating agent and pH value of aqueous solutions. The ESR spectra of the samples were obtained at room temperature and at 230 K. The field cooling (FC) experiment was performed for selected samples, and the effective anisotropy field (H{sub K2}) and the first order magnetocrystalline anisotropy constant (K{sub 1}) was calculated. The process of the nanoparticles diffusion in different environments (human blood, human serum) forced by an inhomogeneous magnetic field was monitored and their interactions with different solvents have been discussed. It has been shown that ESR method is useful to observe the impact of organic ligands at the magnetite surface, type of coating agent and pH value of aqueous solutions on the properties of iron(II,III) oxide nanoparticles. - Highlights: • The influence of different organic ligands, coatings and pH values of aqueous solutions on the physical properties of the magnetite nanoparticles studied by ESR method. • Nanoparticles diffusion forced by inhomogeneous magnetic field monitored by ESR and explained. • A narrow line separated in ESR spectra by CREM. • The influence of different coatings and pH values of aqueous solutions on ESR spectra of TEMPO attached to the magnetite core.

  5. ESR statement on radiation protection: globalisation, personalised medicine and safety (the GPS approach).

    Science.gov (United States)

    2013-12-01

    In keeping with its responsibility for the radiation protection of patients undergoing radiological examinations and procedures, as well as of staff who are getting exposed, and with due regard to requirements under European Directives, the European Society of Radiology (ESR) issues this statement. It provides a holistic approach, termed as Globalisation (indicating all the steps and involving all stakeholders), Personalisation (referring to patient-centric) and Safety-thus called GPS. While being conscious that there is need to increase access of radiological imaging, ESR is aware about the increasing inappropriate medical exposures to ionising radiation and wide variation in patient doses for the same examination. The ESR is convinced that the different components of radiation protection are often interrelated and cannot be considered in isolation The ESR's GPS approach stands for: Globalisation (indicating all the steps and involving all stakeholders), Personalisation (referring to patient-centric) and Safety-thus called GPS It can be anticipated that enhanced protection of patients in Europe will result through the GPS approach. Although the focus is on patient safety, staff safety issues will find a place wherever pertinent.

  6. The ESR dating of the Nanjing Homo erectus stratigraphy

    International Nuclear Information System (INIS)

    Chen Tiemei; Wu En; Yang Quan; Hu Yanqiu

    1997-01-01

    Five fossil tooth enamel samples collected from the stratum of the Nanjing Homo erectus were ESR dated. The average age is 355 +- 42 ka, based on the early uranium-uptake model. Additional uranium series measurement of fossil teeth confirms the appropriateness of the early uranium-uptake model for these ESR samples. Considering also the uranium-series ages of two calcite samples from the flow stone covering the fossil-containing stratum, an age value of 350 +- 50 ka for the Nanjing Homo erectus stratum is evaluated, which means that the Nanjing Homo erectus appeared in the late stage of Peking Man and also in the stage of human evolution earlier than Hexian Homo erectus

  7. Ultrafast Structural Dynamics in InSb Probed by Time-Resolved X-Ray Diffraction

    International Nuclear Information System (INIS)

    Chin, A.H.; Shank, C.V.; Chin, A.H.; Schoenlein, R.W.; Shank, C.V.; Glover, T.E.; Leemans, W.P.; Balling, P.

    1999-01-01

    Ultrafast structural dynamics in laser-perturbed InSb are studied using time-resolved x-ray diffraction with a novel femtosecond x-ray source. We report the first observation of a delay in the onset of lattice expansion, which we attribute to energy relaxation processes and lattice strain propagation. In addition, we observe direct indications of ultrafast disordering on a subpicosecond time scale. copyright 1999 The American Physical Society

  8. ESR dating of marine fossil shells

    International Nuclear Information System (INIS)

    Radtke, U.; Mangini, A.; Gruen, R.

    1985-01-01

    In order to establish the relatively new ESR dating method for marine shells a detailed comparison with the independent U-series technique was carried out. Agreement of both dating methods with the geological classification is strongly dependent on the species investigated and environmental conditions. Several problems encountered in the determination of the accumulated dose as well as the annual dose are discussed. (author)

  9. ESR dating of marine fossil shells

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, U; Mangini, A; Gruen, R

    1985-01-01

    In order to establish the relatively new ESR dating method for marine shells a detailed comparison with the independent U-series technique was carried out. Agreement of both dating methods with the geological classification is strongly dependent on the species investigated and environmental conditions. Several problems encountered in the determination of the accumulated dose as well as the annual dose are discussed.

  10. Effects of gamma-irradiation on the erythrocyte membrane: ESR, NMR and biochemical studies

    International Nuclear Information System (INIS)

    Cantafora, A.; Ceccarini, M.; Guidoni, L.; Ianzini, F.; Minetti, M.; Viti, V.

    1987-01-01

    The effects of gamma-irradiation on resealed erythrocyte ghosts have been examined with different techniques. Phospholipid analysis reveals peroxidative damage on the polyunsaturated chains of phosphatidylethanolamine. Gel electrophoresis and ESR measurements indicate modifications of the cytoskeletal proteins. 31 P nuclear magnetic resonance data show bilayer modifications that can be interpreted as changes in lipid-protein interactions. The overall picture from the present results favours interaction between lipids and proteins in the inner monolayer of the membrane. (author)

  11. Simulation of multi-photon emission isotopes using time-resolved SimSET multiple photon history generator

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Chih-Chieh; Lin, Hsin-Hon; Lin, Chang-Shiun; Chuang, Keh-Shih [Department of Biomedical Engineering and Environmental Sciences, National Tsing-HuaUniversity, Hsinchu, Taiwan (China); Jan, Meei-Ling [Health Physics Division, Institute of Nuclear Energy Research, Atomic Energy Council, Taoyuan, Taiwan (China)

    2015-07-01

    Abstract-Multiple-photon emitters, such as In-111 or Se-75, have enormous potential in the field of nuclear medicine imaging. For example, Se-75 can be used to investigate the bile acid malabsorption and measure the bile acid pool loss. The simulation system for emission tomography (SimSET) is a well-known Monte Carlo simulation (MCS) code in nuclear medicine for its high computational efficiency. However, current SimSET cannot simulate these isotopes due to the lack of modeling of complex decay scheme and the time-dependent decay process. To extend the versatility of SimSET for simulation of those multi-photon emission isotopes, a time-resolved multiple photon history generator based on SimSET codes is developed in present study. For developing the time-resolved SimSET (trSimSET) with radionuclide decay process, the new MCS model introduce new features, including decay time information and photon time-of-flight information, into this new code. The half-life of energy states were tabulated from the Evaluated Nuclear Structure Data File (ENSDF) database. The MCS results indicate that the overall percent difference is less than 8.5% for all simulation trials as compared to GATE. To sum up, we demonstrated that time-resolved SimSET multiple photon history generator can have comparable accuracy with GATE and keeping better computational efficiency. The new MCS code is very useful to study the multi-photon imaging of novel isotopes that needs the simulation of lifetime and the time-of-fight measurements. (authors)

  12. The ESR dating of fossil enamel samples from palaeo-anthropological and Palaeolithic sites of Early Pleistocene

    International Nuclear Information System (INIS)

    Chen Qi; Chen Tiemei; Li Jiuqiang

    1999-01-01

    The following problems regarding the ESR dating of fossil enamel samples from palaeo-anthropological and Palaeolithic sites of Early Pleistocene are discussed: 1) the applicability of exponential fitting in the additive method for reliable AD determination; 2) the thermo-stability of the g = 2.0018 line of hydroxyapatite and its influence on apparent ESR ages; 3) the right selection of U-uptake models; and 4) the effect of high U-content in enamel on the ESR ages. It is concluded that the ESR-EU ages of Early Pleistocene enamel samples can only be regarded as the lower limit of the true ages if no appropriate corrections for the factors discussed above are made

  13. Time-resolved terahertz spectroscopy of conjugated polymer/CdSe nanorod composites

    DEFF Research Database (Denmark)

    Cooke, David; Lek, Jun Y.; Krebs, Frederik C

    2010-01-01

    report ultrafast carrier dynamics in hybrid CdSe nanorod / poly(3-hexythiophene) (P3HT) bulk heterojunction films measured by time-resolved terahertz spectroscopy, and compare to the well studied P3HT/phenyl-C61-butyric acid methyl ester (PCBM) blend. Both films show an improved peak...... photoconductivity compared to P3HT alone, consistent with efficient charge transfer. The photoconductivity dynamics show fast, picosecond trapping or recombination in the hybrid blend while the all-organic film shows no such loss of mobile charge over ns time scales. The ac conductivity for all samples is well...

  14. Studying electron distributions using the time-resolved free-bound spectra from coronal plasmas

    International Nuclear Information System (INIS)

    Matthews, D.L.; Kauffman, R.L.; Kilkenny, J.D.; Lee, R.W.

    1982-11-01

    Absorption of laser light in a plasma by inverse bremsstrahlung, I.B., can lead to a non-Maxwellian velocity distribution provided the electron-elecron collision frequency is too low to equilibrate the velocity distribution in the coronal plasma region of a laser heated aluminum disk by measuring the radiation recombination continuum. The experiments are performed using lambda/sub L/ = 0.532 μm laser light at intensities of approx. 10 16 W/cm 2 . Such parameters are predicted to produce conditions suitable for a non-thermal electron distribution. The shape of the K-shell recombination radiation has been measured using a time-resolved x-ray spectrograph. The electron distribution can be determined from deconvolution of the recombination continuum shape

  15. Time Resolved Broadband Terahertz Relaxation Dynamics of Electron in Water

    DEFF Research Database (Denmark)

    Wang, Tianwu; Iwaszczuk, Krzysztof; Cooke, David G.

    We investigated the transient response of the solvated electron in water ejected by photodetachment from potassium ferrocyanide using time resolved terahertz spectroscopy (TSTS). Ultrabroadband THz transients are generated and detected by a two-color femtosecond-induced air plasma and air biased...

  16. ESR study of the effects of water, methanol, and ethanol on gamma-irradiation of starch

    International Nuclear Information System (INIS)

    Henderson, A.M.; Rudin, A.

    1981-01-01

    This investigation deals with the nature and relative abundance of stable radicals formed by gamma-irradiation of wheat starch at room temperature. Additions of equal weights of water, methanol, and ethanol were equally effective in reducing the content of stable radicals in starch which contained about 12% water before the additions. When, however, the starting material was dried starch with 2.9% initial water content additional water and methanol were better radical scavengers than ethanol. This difference is attributed to the superior ability of water and methanol to permeate the starch structure. Superficially different ESR spectra were obtained in products made by irradiating starch and starch that contained added water or methanol. Computer simulation of these spectra showed that they could be matched by superposition of the spectra of the same four component radicals, with some adjustments of relative intensities and peak widths. The structure of these radicals have been deduced from the spectral assignments and relative effects of the three solvents used on the intensities of the respective ESR spectra

  17. Researches and Applications of ESR Dosimetry for Radiation Accident Dose Assessment

    International Nuclear Information System (INIS)

    Wu, K.; Guo, L.; Cong, J.B.; Sun, C.P.; Hu, J.M.; Zhou, Z.S.; Wang, S.; Zhang, Y.; Zhang, X.; Shi, Y.M.

    1998-01-01

    The aim of this work was to establish methods suitable for practical dose assessment of people involved in ionising radiation accidents. Some biological materials of the human body and materials possibly carried or worn by people were taken as detection samples. By using electron spin resonance (ESR) techniques, the basic dosimetric properties of selected materials were investigated in the range above the threshold dose of human acute haemopoietic radiation syndrome. The dosimetric properties involved included dose response properties of ESR signals, signal stabilities, distribution of background signals, the lowest detectable dose value, radiation conditions, environmental effects on the detecting process, etc. Several practical dose analytical indexes and detecting methods were set up. Some of them (bone, watch glass and tooth enamel) had also been successfully used in the dose assessment of people involved in three radiation accidents, including the Chernobyl reactor accident. This work further proves the important role of ESR techniques in radiation accident dose estimation. (author)

  18. ESR dosimetric properties of some biomineral materials

    International Nuclear Information System (INIS)

    Hassan, Gamal M.; Sharaf, M.A.

    2005-01-01

    Dosimetric properties of g-irradiated modern coral and bioactive glass (Bio-G) samples analyzed with electron spin resonance (ESR) have been separately reported (Hassan et al., 2004; Sharaf and Hassan, 2004) and compared with alanine. These are combined here to allow a three-way comparison between these materials

  19. ESR dosimetric properties of some biomineral materials

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Gamal M. [Department of Ionizing Radiation Metrology, National Institute for Standards (NIS), Tersa Street, El-Haram, El-Giza, P.O. Box 136 Giza, El-Giza (Egypt)]. E-mail: gamalhassan65@hotmail.com; Sharaf, M.A. [Department of Ionizing Radiation Metrology, National Institute for Standards (NIS), Tersa Street, El-Haram, El-Giza, P.O. Box 136 Giza, El-Giza (Egypt)

    2005-02-01

    Dosimetric properties of g-irradiated modern coral and bioactive glass (Bio-G) samples analyzed with electron spin resonance (ESR) have been separately reported (Hassan et al., 2004; Sharaf and Hassan, 2004) and compared with alanine. These are combined here to allow a three-way comparison between these materials.

  20. Study of the photoexcited carrier dynamics in InP:Fe using time-resolved reflection and photoluminescence spectra

    International Nuclear Information System (INIS)

    Huang Shihua; Li Xi; Lu Fang

    2004-01-01

    The photoexcited carrier dynamics and photoluminescence of the undoped InP and Fe implanted InP was studied by time-resolved reflection and photoluminescence spectra. The decay times of reflection recovery and the radiative recombination for Fe implanted InP are shorter than those of undoped InP. Considering the surface recombination, a model was developed to simulate the reflection recovery dynamics, it agrees with the experimental results very well. Moreover, we obtained the ambipolar diffusion coefficient and the surface recombination velocity by using the model. For Fe-doped InP, the surface recombination velocity is much larger than that for the undoped InP, which is probably due to Fe 2+/3+ trapping centers and the large surface band bending. The PL decay time for Fe implanted InP is shorter than that for undoped InP, which is ascribed to the capture centers introduced by metallic precipitates

  1. MCNP simulations of a new time-resolved Compton scattering imaging technique

    International Nuclear Information System (INIS)

    Ilan, Y.

    2004-01-01

    Medical images of human tissue can be produced using Computed Tomography (CT), Positron Emission Tomography (PET), Ultrasound or Magnetic Resonance Imaging (MRI). In all of the above techniques, in order to get a three-dimensional (3D) image, one has to rotate or move the source, the detectors or the scanned target. This procedure is complicated, time consuming and increases the cost and weight of the scanning equipment. Time resolved optical tomography has been suggested as an alternative to the above conventional methods. This technique implies near infrared light (NIR) and fast time-resolved detectors to obtain a 3D image of the scanned target. However, due to the limited penetration of the NIR light in the tissue, the application of this technique is limited to soft tissue like a female breast or a premature infant brain

  2. Reduction of Poisson noise in measured time-resolved data for time-domain diffuse optical tomography.

    Science.gov (United States)

    Okawa, S; Endo, Y; Hoshi, Y; Yamada, Y

    2012-01-01

    A method to reduce noise for time-domain diffuse optical tomography (DOT) is proposed. Poisson noise which contaminates time-resolved photon counting data is reduced by use of maximum a posteriori estimation. The noise-free data are modeled as a Markov random process, and the measured time-resolved data are assumed as Poisson distributed random variables. The posterior probability of the occurrence of the noise-free data is formulated. By maximizing the probability, the noise-free data are estimated, and the Poisson noise is reduced as a result. The performances of the Poisson noise reduction are demonstrated in some experiments of the image reconstruction of time-domain DOT. In simulations, the proposed method reduces the relative error between the noise-free and noisy data to about one thirtieth, and the reconstructed DOT image was smoothed by the proposed noise reduction. The variance of the reconstructed absorption coefficients decreased by 22% in a phantom experiment. The quality of DOT, which can be applied to breast cancer screening etc., is improved by the proposed noise reduction.

  3. Microcontroller based resonance tracking unit for time resolved continuous wave cavity-ringdown spectroscopy measurements.

    Science.gov (United States)

    Votava, Ondrej; Mašát, Milan; Parker, Alexander E; Jain, Chaithania; Fittschen, Christa

    2012-04-01

    We present in this work a new tracking servoloop electronics for continuous wave cavity-ringdown absorption spectroscopy (cw-CRDS) and its application to time resolved cw-CRDS measurements by coupling the system with a pulsed laser photolysis set-up. The tracking unit significantly increases the repetition rate of the CRDS events and thus improves effective time resolution (and/or the signal-to-noise ratio) in kinetics studies with cw-CRDS in given data acquisition time. The tracking servoloop uses novel strategy to track the cavity resonances that result in a fast relocking (few ms) after the loss of tracking due to an external disturbance. The microcontroller based design is highly flexible and thus advanced tracking strategies are easy to implement by the firmware modification without the need to modify the hardware. We believe that the performance of many existing cw-CRDS experiments, not only time-resolved, can be improved with such tracking unit without any additional modification to the experiment. © 2012 American Institute of Physics

  4. Time resolved high frequency spectrum of Br2 molecules using pulsed photoacoustic technique.

    Science.gov (United States)

    Yehya, Fahem; Chaudhary, A K

    2013-11-01

    The paper reports the time resolved spectral distribution of higher order acoustic modes generated in Br2 molecules using pulsed Photoacoustic (PA) technique. New time resolved vibrational spectrum of Br2 molecules are recorded using a single 532nm, pulses of 7ns duration at 10Hz repetition rate obtained from Q-switched Nd:YAG laser. Frank-Condon principle based assignments confirms the presence of 12 numbers of (ν″-ν') vibrational transitions covered by a single 532+2nm pulse profile. Inclusions of higher order zeroth modes in Bassel's function expansion series shows the probability of overlapping of different types of acoustic modes in the designed PA cells. These modes appear in the form of clusters which occupies higher frequency range. The study of decay behavior of PA signal with respect to time confirms the photolysis of Br2 at 532nm wavelength. In addition, the shifting and clustering effect of cavity eigen modes in Br2 molecules have been studied between 1 and 10ms time scale. The estimated Q-factor of PA cell (l=16cm, R=1.4cm) is 145±4 at 27kHz frequency. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Study of intrinsic energy dependence of α-alanine and dose intercomparison with ESR and ISE techniques

    International Nuclear Information System (INIS)

    Laere, K. van; Bartolotta, A.; Callens, F.

    1993-01-01

    The intrinsic energy behavior of the radiation chemical yields G(R ·) and G(NH 3 ) which determine the dose response for the alanine/ESR and alanine/Ion-Selective Electrode (ISE) system, is an important characteristic for the consistent use in different radiation environments. Therefore, the response of ISS and Gent α-alanine dosimeters in the dose range 0.1 to 700 kGy was examined with 60 Co, bremsstrahlung and electron beam radiation. Bremsstrahlung beams with end point energy between 5 and 12 MeV and electron beams with mean energy at the effective point of measurement between 4 and 25 MeV were used. Analysis of the 60 Co calibration results shows that there are no significant differences in dose determination between the two laboratories. The statistical evaluation of 41 sets of independent series of measurements has shown no significant variation with beam energy. The results also confirm good consistency between ISE and ESR measurements. (author)

  6. Determination of quenching coefficients by time resolved emission spectroscopy

    International Nuclear Information System (INIS)

    Gans, T.; Schulz-von der Gathen, V.; Doebele, H.F.

    2001-01-01

    Capacitively coupled RF discharges (CCRF discharges) at 13.56 MHz in hydrogen exhibit a field reversal phase of about 10 ns during which an intense electron current provides collisional excitation, within the sheath region. After this strongly dominant short pulsed electron impact excitation, it is possible to determine quenching coefficients from the lifetime of the fluorescence at various pressures by time resolved OES even for high energy levels and without any restrictions of optical selection rules. This novel technique allows the measurement of quenching coefficients for atomic and molecular emission lines of hydrogen itself, as well as for emission lines of small admixtures (e.g. noble gases) to the hydrogen discharge, since with a fast gate-able ICCD camera operating at 13.56 MHz it is possible to measure even faint emission lines temporally resolved

  7. Determination of quenching coefficients by time resolved emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gans, T.; Schulz-von der Gathen, V.; Doebele, H.F. [Essen Univ. (Gesamthochschule) (Germany). Inst. fuer Laser- und Plasmaphysik

    2001-07-01

    Capacitively coupled RF discharges (CCRF discharges) at 13.56 MHz in hydrogen exhibit a field reversal phase of about 10 ns during which an intense electron current provides collisional excitation, within the sheath region. After this strongly dominant short pulsed electron impact excitation, it is possible to determine quenching coefficients from the lifetime of the fluorescence at various pressures by time resolved OES even for high energy levels and without any restrictions of optical selection rules. This novel technique allows the measurement of quenching coefficients for atomic and molecular emission lines of hydrogen itself, as well as for emission lines of small admixtures (e.g. noble gases) to the hydrogen discharge, since with a fast gate-able ICCD camera operating at 13.56 MHz it is possible to measure even faint emission lines temporally resolved.

  8. Developments in time-resolved x-ray research at APS beamline 7ID

    Energy Technology Data Exchange (ETDEWEB)

    Walko, D. A., E-mail: d-walko@anl.gov; Adams, B. W.; Doumy, G.; Dufresne, E. M.; Li, Yuelin; March, A. M.; Sandy, A. R.; Wang, Jin; Wen, Haidan; Zhu, Yi [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-07-27

    The 7ID beamline of the Advanced Photon Source (APS) is dedicated to time-resolved research using x-ray imaging, scattering, and spectroscopy techniques. Time resolution is achieved via gated detectors and/or mechanical choppers in conjunction with the time structure of the x-ray beam. Three experimental hutches allow for a wide variety of experimental setups. Major areas of research include atomic, molecular, and optical physics; chemistry; condensed matter physics in the bulk, thin film, and surface regimes; and fluid-spray dynamics. Recent developments in facilities at 7ID include a high-power, high-repetition-rate picosecond laser to complement the 1 kHz ultrafast laser. For the ultrafast laser, a newly commissioned optical parametric amplifier provides pump wavelength from 0.2 to 15 µm with energy per pulse up to 200 µJ. A nanodiffraction station has also been commissioned, using Fresnel zone-plate optics to achieve a focused x-ray spot of 300 nm. This nanoprobe is not only used to spatially resolve the evolution of small features in samples after optical excitation, but also has been combined with an intense THz source to study material response under ultrafast electric fields.

  9. Combined PIXE and X-ray SEM studies on time-resolved deposits of welding shop aerosols

    International Nuclear Information System (INIS)

    Barfoot, K.M.; Mitchell, I.V.; Verheyen, F.; Babeliowsky, T.

    1981-01-01

    Time-resolved deposits of welding shop air particulates have been obtained using a streak sampling system. PIXE analysis of these deposits, using 2 MeV protons, typically revealed the presence of a large number of elements, with many in the range Z = 11-30. Strong variations, up to three orders of magnitude, in the concentrations of several elements such as Al, Si and Fe as well as Zn, Na, K and Ca were found. The 2 h sampling resolution normally used was found to be insufficient to follow the short pollution episodes that regularly occur in a welding shop environment and so sampling with a 20 min resolution was used. The variation of elemental concentrations for different sampling times together with information on the physical nature of these air particulates, determined with a scanning electron microscope (SEM) and Si(Li) X-ray detector attachment, are presented. This type of information together with that obtained from the PIXE analysis is of importance industrial hygiene studies. The need to make corrections for partial filter clogging, based on air-flow rate monitoring, is discussed. (orig.)

  10. Time-resolved diffusion tomographic imaging in highly scattering turbid media

    Science.gov (United States)

    Alfano, Robert R. (Inventor); Cai, Wei (Inventor); Liu, Feng (Inventor); Lax, Melvin (Inventor); Das, Bidyut B. (Inventor)

    1998-01-01

    A method for imaging objects in highly scattering turbid media. According to one embodiment of the invention, the method involves using a plurality of intersecting source/detectors sets and time-resolving equipment to generate a plurality of time-resolved intensity curves for the diffusive component of light emergent from the medium. For each of the curves, the intensities at a plurality of times are then inputted into the following inverse reconstruction algorithm to form an image of the medium: X.sup.(k+1).spsp.T =?Y.sup.T W+X.sup.(k).spsp.T .LAMBDA.!?W.sup.T W+.LAMBDA.!.sup.-1 wherein W is a matrix relating output at detector position r.sub.d, at time t, to source at position r.sub.s, .LAMBDA. is a regularization matrix, chosen for convenience to be diagonal, but selected in a way related to the ratio of the noise, to fluctuations in the absorption (or diffusion) X.sub.j that we are trying to determine: .LAMBDA..sub.ij =.lambda..sub.j .delta..sub.ij with .lambda..sub.j =/ Here Y is the data collected at the detectors, and X.sup.k is the kth iterate toward the desired absoption information.

  11. Magnetization and ESR studies of La{sub 0.67}(Ca{sub 1−x}Mg{sub x}){sub 0.33}MnO{sub 3} systems

    Energy Technology Data Exchange (ETDEWEB)

    Sendil Kumar, A., E-mail: sendilphy@gmail.com [School of Physics, University of Hyderabad, Hyderabad, Telangana, 500 046 (India); Ravinder Reddy, K [School of Engineering Sciences & Technology, University of Hyderabad, Hyderabad, Telangana, 500 046 (India); Bhatnagar, Anil K. [School of Physics, University of Hyderabad, Hyderabad, Telangana, 500 046 (India); School of Engineering Sciences & Technology, University of Hyderabad, Hyderabad, Telangana, 500 046 (India)

    2015-08-05

    Highlights: • Mg substitution reduces the ferromagnetic strength. • Inhomogeneous broadening is due to phase separation. • Griffiths phase existence is probed. - Abstract: Magnetization studies and line shape analysis on Electron Spin Resonance (ESR) spectra of La{sub 0.67}(Ca{sub 1−x}Mg{sub x}){sub 0.33}MnO{sub 3} are carried out. In paramagnetic phase well above T{sub c}, the ESR spectra are single Lorentzian but below and near T{sup ∗}{sub ΔHPP}, (T{sup ∗}{sub ΔHPP} is temperature at which line width is minimum) inhomogeneous broadening with asymmetry in the signal is observed due to phase separation. The resonance field below T{sup ∗}{sub ΔHPP} decreases with decreasing temperature. Above T{sub c} the intensity of the ESR spectra obeys the thermally activated model (Arrhenius behavior). Substitution of Mg weakens the ferromagnetic interaction and evolution of change in lineshape near T{sub c} is an evidence of Griffiths phase (coexistence of paramagnetic and ferromagnetic) in Mg doped LCMO system.

  12. Characterization of type I, II, III, IV, and V collagens by time-resolved laser-induced fluorescence spectroscopy

    Science.gov (United States)

    Marcu, Laura; Cohen, David; Maarek, Jean-Michel I.; Grundfest, Warren S.

    2000-04-01

    The relative proportions of genetically distinct collagen types in connective tissues vary with tissue type and change during disease progression, development, wound healing, aging. This study aims to 1) characterize the spectro- temporal fluorescence emission of fiber different types of collagen and 2) assess the ability of time-resolved laser- induced fluorescence spectroscopy to distinguish between collagen types. Fluorescence emission of commercially available purified samples was induced with nitrogen laser excitation pulses and detected with a MCP-PMT connected to a digital storage oscilloscope. The recorded time-resolved emission spectra displayed distinct fluorescence emission characteristics for each collagen type. The time domain information complemented the spectral domain intensity data for improved discrimination between different collagen types. Our results reveal that analysis of the fluorescence emission can be used to characterize different species of collagen. Also, the results suggest that time-resolved spectroscopy can be used for monitoring of connective tissue matrix composition changes due to various pathological and non-pathological conditions.

  13. Erythrocyte Sedimentation Rate (ESR): MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Erythrocyte Sedimentation Rate (ESR); p. 267– ...

  14. Mix and Inject: Reaction Initiation by Diffusion for Time-Resolved Macromolecular Crystallography

    Directory of Open Access Journals (Sweden)

    Marius Schmidt

    2013-01-01

    Full Text Available Time-resolved macromolecular crystallography unifies structure determination with chemical kinetics, since the structures of transient states and chemical and kinetic mechanisms can be determined simultaneously from the same data. To start a reaction in an enzyme, typically, an initially inactive substrate present in the crystal is activated. This has particular disadvantages that are circumvented when active substrate is directly provided by diffusion. However, then it is prohibitive to use macroscopic crystals because diffusion times become too long. With small micro- and nanocrystals diffusion times are adequately short for most enzymes and the reaction can be swiftly initiated. We demonstrate here that a time-resolved crystallographic experiment becomes feasible by mixing substrate with enzyme nanocrystals which are subsequently injected into the X-ray beam of a pulsed X-ray source.

  15. Time-resolved optically-detected magnetic resonance of II-VI diluted-magnetic-semiconductor heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, V.Yu.; Karczewski, G. [Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw (Poland); Godlewski, M. [Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw (Poland); Dept. Mathem. and Natural Sci. College of Sci., Card. S. Wyszynski Univ., Warsaw (Poland); Yakovlev, D.R. [Experimental Physics 2, University of Dortmund, 44221 Dortmund (Germany); A. F. Ioffe Physico-Technical Institute, 194017 St. Petersburg (Russian Federation); Ryabchenko, S.M. [Institute of Physics NAS Ukraine, 03028 Kiev (Ukraine); Waag, A. [Institute of Semiconductor Technology, Braunschweig Technical University, 38106 Braunschweig (Germany)

    2007-01-15

    Time-resolved optically-detected magnetic resonance (ODMR) technique was used to study spin dynamics of Mn{sup 2+} ions in (Zn,Mn)Se- and (Cd,Mn)Te-based diluted magnetic semiconductor quantum wells. Times of spin-lattice relaxation have been measured directly from a dynamical shift of exciton luminescence lines after a pulsed impact of 60 GHz microwave radiation. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  16. Thermally activated delayed fluorescence of fluorescein derivative for time-resolved and confocal fluorescence imaging.

    Science.gov (United States)

    Xiong, Xiaoqing; Song, Fengling; Wang, Jingyun; Zhang, Yukang; Xue, Yingying; Sun, Liangliang; Jiang, Na; Gao, Pan; Tian, Lu; Peng, Xiaojun

    2014-07-09

    Compared with fluorescence imaging utilizing fluorophores whose lifetimes are in the order of nanoseconds, time-resolved fluorescence microscopy has more advantages in monitoring target fluorescence. In this work, compound DCF-MPYM, which is based on a fluorescein derivative, showed long-lived luminescence (22.11 μs in deaerated ethanol) and was used in time-resolved fluorescence imaging in living cells. Both nanosecond time-resolved transient difference absorption spectra and time-correlated single-photon counting (TCSPC) were employed to explain the long lifetime of the compound, which is rare in pure organic fluorophores without rare earth metals and heavy atoms. A mechanism of thermally activated delayed fluorescence (TADF) that considers the long wavelength fluorescence, large Stokes shift, and long-lived triplet state of DCF-MPYM was proposed. The energy gap (ΔEST) of DCF-MPYM between the singlet and triplet state was determined to be 28.36 meV by the decay rate of DF as a function of temperature. The ΔE(ST) was small enough to allow efficient intersystem crossing (ISC) and reverse ISC, leading to efficient TADF at room temperature. The straightforward synthesis of DCF-MPYM and wide availability of its starting materials contribute to the excellent potential of the compound to replace luminescent lanthanide complexes in future time-resolved imaging technologies.

  17. Examining Electron-Boson Coupling Using Time-Resolved Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sentef, Michael; Kemper, Alexander F.; Moritz, Brian; Freericks, James K.; Shen, Zhi-Xun; Devereaux, Thomas P.

    2013-12-26

    Nonequilibrium pump-probe time-domain spectroscopies can become an important tool to disentangle degrees of freedom whose coupling leads to broad structures in the frequency domain. Here, using the time-resolved solution of a model photoexcited electron-phonon system, we show that the relaxational dynamics are directly governed by the equilibrium self-energy so that the phonon frequency sets a window for “slow” versus “fast” recovery. The overall temporal structure of this relaxation spectroscopy allows for a reliable and quantitative extraction of the electron-phonon coupling strength without requiring an effective temperature model or making strong assumptions about the underlying bare electronic band dispersion.

  18. Speciation of actinides in aqueous solution by time-resolved laser-induced fluorescence spectroscopy (TRLFS)

    International Nuclear Information System (INIS)

    Kimura, Takaumi; Kato, Yoshiharu; Meinrath, G.; Yoshida, Zenko; Choppin, G.R.

    1995-01-01

    Time-resolved laser-induced fluorescence spectroscopy (TRLFS) as a sensitive and selective method has been applied to the speciation of actinides in aqueous solution. Studies on hydrolysis and carbonate complexation of U(VI) and on determination of hydration number of Cm(III) are reported. (author)

  19. Time-resolved investigation of an asymmetric bipolar pulsed magnetron deposition discharge: Influence of pressure

    NARCIS (Netherlands)

    Dunger, Th.; Welzel, Th.; Welzel, S.; Richter, F.

    2005-01-01

    A bipolar pulsed magnetron deposition discharge has been studied with pulse frequencies of 100 and 150 kHz, respectively. The discharge was operated in an argon/oxygen mixture at different total pressures with a circular magnesium target as cathode. Time-resolved Langmuir double probe measurements

  20. Time-resolved EPR study of singlet oxygen in the gas phase.

    Science.gov (United States)

    Ruzzi, Marco; Sartori, Elena; Moscatelli, Alberto; Khudyakov, Igor V; Turro, Nicholas J

    2013-06-27

    X-band EPR spectra of singlet O2((1)Δg) and triplet O2((3)Σg(-)) were observed in the gas phase under low molecular-oxygen pressures PO2 = 0.175-0.625 Torr, T = 293-323 K. O2((1)Δg) was produced by quenching of photogenerated triplet sensitizers naphthalene C8H10, perdeuterated naphthalene, and perfluoronaphthalene in the gas phase. The EPR spectrum of O2((1)Δg) was also observed under microwave discharge. Integrated intensities and line widths of individual components of the EPR spectrum of O2((3)Σg(-)) were used as internal standards for estimating the concentration of O2 species and PO2 in the EPR cavity. Time-resolved (TR) EPR experiments of C8H10 were the main focus of this Article. Pulsed irradiation of C8H10 in the presence of O2((3)Σg(-)) allowed us to determine the kinetics of formation and decay for each of the four components of the O2((1)Δg) EPR signal, which lasted for only a few seconds. We found that the kinetics of EPR-component decay fit nicely to a biexponential kinetics law. The TR EPR 2D spectrum of the third component of the O2((1)Δg) EPR spectrum was examined in experiments using C8H10. This spectrum vividly presents the time evolution of an EPR component. The largest EPR signal and the longest lifetime of O2((1)Δg), τ = 0.4 s, were observed at medium pressure PO2 = 0.4 Torr, T = 293 K. The mechanism of O2((1)Δg) decay in the presence of photosensitizers is discussed. EPR spectra of O2((1)Δg) evidence that the spin-rotational states of O2((1)Δg) are populated according to Boltzmann distribution in the studied time range of 10-100 ms. We believe that this is the first report dealing with the dependence of O2((1)Δg) EPR line width on PO2 and T.