WorldWideScience

Sample records for time-density curve angiographic

  1. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

    Science.gov (United States)

    Dohatcu, A; Ionita, C N; Paciorek, A; Bednarek, D R; Hoffmann, K R; Rudin, S

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification.

  2. Evaluation of angiographic delayed vasospasm due to ruptured aneurysm in comparison with cerebral circulation time measured by IA-DSA

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Yoshikazu; Shima, Takeshi; Nishida, Masahiro; Yamane, Kanji; Okita, Shinji; Hatayama, Takashi; Yoshida, Akira; Naoe, Yasutaka; Shiga, Naoko (Chugoku Rosai Hospital, Hiroshima (Japan))

    1994-05-01

    Delayed vasospasm due to ruptured aneurysm has been basically evaluated by angiographic changes in contrast to clinical features such as delayed ischemic neurological deficits (DIND). However, the discrepancies between angiographic and clinical findings have been pointed out. In this study, angiographic changes and cerebral circulation time in ruptured aneurysms were simultaneously investigated with IA-DSA. Thirty-two patients, who had ruptured aneurysms at the anterior circle of Willis and neck clippings at the acute stage, were investigated. Carotid angiogram was performed with IA-DSA on the 7-13th day after the attack. Angiographic changes were evaluated by Fischer's classification and circulation time was calculated in the following way. A time-density curve was obtained at the two ROI's: the C3-C4 portion and the rolandic vein. Circulation time was defined by the difference between the time showing peak optical density at the carotid and the venous portion. The control value of this circulation time obtained from 20 cases with non-rupture aneurysm and epilepsy was 3.4 sec (53 year old) on the average. X-ray CT scan examination was performed at the same time and clinical features were observed every day. Angiographically, 3 cases were free from vasospasm, 18 cases were found to present slight to moderate vasospasm, and 11 cases showed severe vasospasm. Circulation time in patients with no spasm was 3.6 seconds, in patients with slight to moderate vasospasm it was 4.3 seconds and in patients with severe vasospasm it was 6.8 seconds. Ten patients showing cerebral infarction on CT scans demonstrated significantly long circulation time, 7.0 seconds on the average. And all patients having severe vasospasm with circulation time more than 6 seconds presented DIND such as hemiparesis. (author).

  3. An angiographic technique for coronary fractional flow reserve measurement: in vivo validation.

    Science.gov (United States)

    Takarada, Shigeho; Zhang, Zhang; Molloi, Sabee

    2013-03-01

    Fractional flow reserve (FFR) is an important prognostic determinant in a clinical setting. However, its measurement currently requires the use of invasive pressure wire, while an angiographic technique based on first-pass distribution analysis and scaling laws can be used to measure FFR using only image data. Eight anesthetized swine were instrumented with flow probe on the proximal segment of the left anterior descending (LAD) coronary arteries. Volumetric blood flow from the flow probe (Qp), coronary pressure (Pa) and right atrium pressure (Pv) were continuously recorded. Flow probe-based FFR (FFRq) was measured from the ratio of flow with and without stenosis. To determine the angiography-based FFR (FFRa), the ratio of blood flow in the presence of a stenosis (QS) to theoretically normal blood flow (QN) was calculated. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. QS was measured using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. QN was estimated from the total coronary arterial volume using scaling laws. Pressure-wire measurements of FFR (FFRp), which was calculated from the ratio of distal coronary pressure (Pd) divided by proximal pressure (Pa), were continuously obtained during the study. A total of 54 measurements of FFRa, FFRp, and FFRq were taken. FFRa showed a good correlation with FFRq (FFRa = 0.97 FFRq +0.06, r(2) = 0.80, p < 0.001), although FFRp overestimated the FFRq (FFRp = 0.657 FFRq + 0.313, r(2) = 0.710, p < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between FFRa and FFRq. This angiographic technique to measure FFR can potentially be used to evaluate both anatomical and physiological assessments of a coronary stenosis during routine diagnostic cardiac catheterization that requires no pressure wires.

  4. A study of low-density areas, clinical findings, and angiographic findings in patients with cerebral infarction

    International Nuclear Information System (INIS)

    Saiki, Iwao; Sakai, Yoshiaki; Oikawa, Tadato; Koide, Kohji; Kanaya, Haruyuki.

    1978-01-01

    55 out of 62 patients with cerebral infarction were investigated in terms of CT scan findings, angiographic findings, and clinical symptoms. The results obtained were as follows: 1) The low-density areas of the CT scan findings were classified into the following four types: large hemispheric or lobular --Type I; wedge-shaped --Type II; small --Type III; and lacunar low-density area. --Type IV. 2) Almost all patients with angiographically occlusive findings showed low-density areas of Type I; however, one patient with ICA occlusion revealed only a lacunar low-density area. 3) The patients with lacunar low-density areas showed an angiographically delayed filling of the angular artery and posterior parietal artery of the middle cerebral artery. 4) The relationship between the types of low-density areas and the clinical conscious disorders was not clear. On the other hand, the patients with Type I low-density areas almost all had motor disturbances, while patients with other types of low-density areas showed only 60 - 70% motor disturbances. 5) In patients with speech disorders, total aphasia cases were found in patients with large hemispheric low-density areas on the left side. Although, motor aphasia cases were seen in patients with various low-density areas on the left inferior frontal and precentral gyri, dysarthria cases were found in the patients with several low-density areas on both sides. 6) The localization of lacunar low-density areas seemed to be near the caudate nucleus on the right side and in the putaminal regions on the left side. The mean and the standard deviation of CT numbers in the lacunar low-density areas showed higher values on the right side than on the left side. (author)

  5. NEW CONCEPTS AND TEST METHODS OF CURVE PROFILE AREA DENSITY IN SURFACE: ESTIMATION OF AREAL DENSITY ON CURVED SPATIAL SURFACE

    OpenAIRE

    Hong Shen

    2011-01-01

    The concepts of curve profile, curve intercept, curve intercept density, curve profile area density, intersection density in containing intersection (or intersection density relied on intersection reference), curve profile intersection density in surface (or curve intercept intersection density relied on intersection of containing curve), and curve profile area density in surface (AS) were defined. AS expressed the amount of curve profile area of Y phase in the unit containing surface area, S...

  6. Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Hamm, Bernd; Dewey, Marc [Humboldt-Universitaet zu Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Duebel, Hans-Peter; Baumann, Gert [Charite - Universitaetsmedizin Berlin, Department of Cardiology, Berlin (Germany); Scholze, Juergen [Charite - Universitaetsmedizin Berlin, Charite Outpatient Centre, Berlin (Germany)

    2007-07-15

    The present study investigated angiographic emulation of multislice computed tomography (MSCT) (catheter-like visualization) as an alternative approach of analyzing and visualizing findings in comparison with standard assessment. Thirty patients (120 coronary arteries) were randomly selected from 90 prospectively investigated patients with suspected coronary artery disease who underwent MSCT (16-slice scanner, 0.5 mm collimation, 400 ms rotation time) prior to conventional coronary angiography for comparison of both approaches. Sensitivity and specificity of angiographic emulation [81% (26/32) and 93% (82/88)] were not significantly different from those of standard assessment [88% (28/32) and 99% (87/88)], while the per-case analysis time was significantly shorter for angiographic emulation than for standard assessment (3.4 {+-} 1.5 vs 7.0 {+-} 2.5 min, P < 0.001). Both interventional and referring cardiologists preferred angiographic emulation over standard curved multiplanar reformations of MSCT coronary angiography for illustration, mainly because of improved overall lucidity and depiction of sidebranches (P < 0.001). In conclusion, angiographic emulation of MSCT reduces analysis time, yields a diagnostic accuracy comparable to that of standard assessment, and is preferred by cardiologists for visualization of results. (orig.)

  7. Coronary angiographic characteristics that influence fractional flow reserve.

    Science.gov (United States)

    Natsumeda, Makoto; Nakazawa, Gaku; Murakami, Tsutomu; Torii, Sho; Ijichi, Takeshi; Ohno, Yohei; Masuda, Naoki; Shinozaki, Norihiko; Ogata, Nobuhiko; Yoshimachi, Fuminobu; Ikari, Yuji

    2015-01-01

    Percutaneous coronary intervention (PCI) guided with fractional flow reserve (FFR) has been shown to improve clinical outcome. Although coronary angiography is the standard method for PCI guidance, the visual severity of stenosis is not always correlated with functional severity, suggesting that there are additional angiographic factors that affect functional ischemia. To evaluate angiographic predictors of positive FFR in stenotic lesions, angiographic characteristics of 260 consecutive patients (362 lesions) who underwent FFR testing from April 2009 to September 2012 were analyzed. A scoring system (STABLED score) using these predictors was developed and compared with quantitative coronary angiography (QCA). %Diameter stenosis >50% (OR, 8.43; P20 mm (OR, 5.40; P=0.0002), and distance from ostium <20 mm (OR, 1.94; P=0.028) were determined as independent predictors of positive FFR. Area under the ROC curve for probability of positive FFR using the STABLED score (Stenosis 2 points, TAndem lesion 1 point, Bifurcation 1 point, LEsion length 1 point, Distance from ostium 1 point) was 0.85, higher than that for QCA stenosis alone (0.76). STABLED score ≥3 had 72.3% sensitivity and 83.6% specificity for predicting positive FFR, and PPV was 76.7%. Specific angiographic features are applicable for predicting functional ischemia. STABLED score correlates well with FFR.

  8. Method for determining scan timing based on analysis of formation process of the time-density curve

    International Nuclear Information System (INIS)

    Yamaguchi, Isao; Ishida, Tomokazu; Kidoya, Eiji; Higashimura, Kyoji; Suzuki, Masayuki

    2005-01-01

    A strict determination of scan timing is needed for dynamic multi-phase scanning and 3D-CT angiography (3D-CTA) by multi-detector row CT (MDCT). In the present study, contrast media arrival time (T AR ) was measured in the abdominal aorta at the bifurcation of the celiac artery for confirmation of circulatory differences in patients. In addition, we analyzed the process of formation of the time-density curve (TDC) and examined factors that affect the time to peak aortic enhancement (T PA ). Mean T AR was 15.57±3.75 s. TDCs were plotted for each duration of injection. The rising portions of TDCs were superimposed on one another. TDCs with longer injection durations were piled up upon one another. Rise angle was approximately constant in response to each flow rate. Rise time (T R ) showed a good correlation with injection duration (T ID ). T R was 1.01 T ID (R 2 =0.994) in the phantom study and 0.94 T lD -0.60 (R 2 =0.988) in the clinical study. In conclusion, for the selection of optimal scan timing it is useful to determine T R at a given point and to determine the time from T AR . (author)

  9. Radiologist and angiographic procedures. Absorbed radiation dose

    International Nuclear Information System (INIS)

    Tryhus, M.; Mettler, F.A. Jr.; Kelsey, C.

    1987-01-01

    The radiation dose absorbed by the angiographer during angiographic procedures is of vital importance to the radiologist. Nevertheless, most articles on the subject are incomplete, and few measure gonadal dose. In this study, three TLDs were used for each of the following sites: radiologist's eyes, thyroid, gonads with and without shielding apron, and hands. The average dose during carotid angiograms was 2.6, 4.1, 0.4, 4.7, and 7.1 mrads to the eyes, thyroid, gonads with and without .5 mm of lead shielding, and hands, respectively. Average dose during abdominal and peripheral vascular angiographic procedures was 5.2, 7.5, 1.2, 8.5, and 39.9 mrads to the eyes, thyroid, gonads with and without shielding, and hands, respectively. A literature review demonstrates a significant reduction in radiation dose to the angiographer after the advent of automated injectors. Our measured doses for carotid angiography are compatible with contemporary reported values. There was poor correlation with fluoroscopy time and measured dose to the angiographer

  10. Comparison of equilibrium radionuclide and contrast angiographic measurements of left ventricular peak ejection and filling rates and their time intervals

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))

    1984-10-01

    A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.

  11. Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film

    Directory of Open Access Journals (Sweden)

    Tatsuhiro Gotanda

    2016-01-01

    Full Text Available Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were −32.336 and −33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range.

  12. Smooth time-dependent receiver operating characteristic curve estimators.

    Science.gov (United States)

    Martínez-Camblor, Pablo; Pardo-Fernández, Juan Carlos

    2018-03-01

    The receiver operating characteristic curve is a popular graphical method often used to study the diagnostic capacity of continuous (bio)markers. When the considered outcome is a time-dependent variable, two main extensions have been proposed: the cumulative/dynamic receiver operating characteristic curve and the incident/dynamic receiver operating characteristic curve. In both cases, the main problem for developing appropriate estimators is the estimation of the joint distribution of the variables time-to-event and marker. As usual, different approximations lead to different estimators. In this article, the authors explore the use of a bivariate kernel density estimator which accounts for censored observations in the sample and produces smooth estimators of the time-dependent receiver operating characteristic curves. The performance of the resulting cumulative/dynamic and incident/dynamic receiver operating characteristic curves is studied by means of Monte Carlo simulations. Additionally, the influence of the choice of the required smoothing parameters is explored. Finally, two real-applications are considered. An R package is also provided as a complement to this article.

  13. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    Science.gov (United States)

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  14. Exposure doses to angiographers during interventional angiography

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yasuhara, Yoshifumi; Sugata, Shigenori; Fujii, Takashi; Kawakami, Toshiaki; Ikezoe, Junpei

    1997-01-01

    We report the exposure doses to angiographers during interventional angiography and the protective efficacy of protective aprons against X-rays in this study. The first (main) angiographer was exposed to the maximum dose of 1 μSv/min at the left chest area and lower abdominal area inside the protective apron. The second (assistant) angiographer was exposed to the maximum dose of 2 μSv/min at the left chest area and 1 μSv/min at the lower abdominal area. X-ray transmission ratio of the protective apron was 4.9 percent or less for UL25L, O percent for 0.35 mmPb and 4.3 percent or less for 0.5 mmPb. These results were lower than the dose equivalent limit based on the laws and ordinances. The protection capacities of these protective aprons proved to be sufficient. The exposure dose at the left extremity area outside the protective apron, however, was 24 times higher than at the left chest area inside. The data showed that it was not protected from scattered X-rays outside the protective apron. It is imperative to consider secondary protective material for the area outside the protective apron. Considering the risk of radiation, we need to better control exposure to angiographers. (author)

  15. Evaluation of cerebral intravascular blood flow by time density curve study of intravenous digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Imamura, Toru; Kogure, Kyuya (Tohoku Univ., Sendai (Japan). School of Medicine); Sekine, Teiko; Satoh, Kei; Endoh, Minoru; Tsuburaya, Kenji; Hoshi, Akihiko

    1992-01-01

    Time density curve (TDC) can be reconstructed from the data of intravenous digital subtraction angiography (IVDSA). We evaluated peak time (PT) and modal transit time (MOTT) of the TDC as the probable indicator of cerebral intravascular blood flow. Cerebral IVDSA and single photon emission CT (SPECT) were performed on 12 patients with ischemic cerebrovascular disease, which consisted of 3 internal carotid artery (ICA) occlusions, one middle cerebral artery (MCA) occlusion, one anterior cerebral artery (ACA) branch occlusion and 7 lacunar infarctions. We classified former 4 patients as occlusion group and latter 8 as reference group. In 3 patients (2 ICA and one MCA occlusions), SPECT study revealed definite hypoaccumulation in the MCA territory of occlusive side. Two regions of interest (ROI) were placed on the territories of right and left middle cerebral arteries in the frontal view of cerebral IVDSA. Digital data processor fitted {gamma} curve to the TDC of each ROI, and calculated PT and MOTT. The absolute lateralities of PT and MOTT of MCA territory was significantly (p<0.05) larger in occlusion group than reference group. Patients with hypoaccumulation in SPECT had significantly (p<0.02) larger laterality of MOTT than patients with isoaccumulation. One ICA occluded patient without hypoaccumulation in corresponding MCA territory had relatively small laterality of MOTT similar to the patients of ACA branch occlusion and lacunar infarction. These results suggest that PT and MOTT are possible to detect the laterality of the intravascular blood flow in MCA territories caused by major artery occlusion. Cerebral TDC study of IVDSA may be useful in some clinical therapeutic situations such as hemodilution or intra-arterial thrombolysis, and worth further clinical evaluation. (author).

  16. Effects of gypsum and bulk density on neutron probe calibration curves

    International Nuclear Information System (INIS)

    Arslan, Awadis; Razzouk, A.K.

    1993-10-01

    The effects of gypsum and bulk density on the neutron probe calibration curve were studied in the laboratory and in the field. The effect of bulk density was negligible for the soil studied in the laboratory, while it was significant for the field calibration. An increase in the slope of moisture content on a volume basis vs. count ratio with increasing gypsum content at the soil was observed in the laboratory calibration. A simple method for correction of the calibration curve for gypsum content was adopted to obtain a specific curve for each layer. The adapted method requires the gypsum fraction to be estimated for each layer and then incorporated in the calibration curve to improve the coefficient of determination. A field calibration showed an improvement of the determination coefficient by introducing bulk density and gypsum fraction, in addition to count ratio using moisture content on a volume basis as a dependent variable in multi linear regression analysis. The same procedure was successful with variable gravel fractions. (author). 18 refs., 3 figs., 2 tabs

  17. Development of theoretical oxygen saturation calibration curve based on optical density ratio and optical simulation approach

    Science.gov (United States)

    Jumadi, Nur Anida; Beng, Gan Kok; Ali, Mohd Alauddin Mohd; Zahedi, Edmond; Morsin, Marlia

    2017-09-01

    The implementation of surface-based Monte Carlo simulation technique for oxygen saturation (SaO2) calibration curve estimation is demonstrated in this paper. Generally, the calibration curve is estimated either from the empirical study using animals as the subject of experiment or is derived from mathematical equations. However, the determination of calibration curve using animal is time consuming and requires expertise to conduct the experiment. Alternatively, an optical simulation technique has been used widely in the biomedical optics field due to its capability to exhibit the real tissue behavior. The mathematical relationship between optical density (OD) and optical density ratios (ODR) associated with SaO2 during systole and diastole is used as the basis of obtaining the theoretical calibration curve. The optical properties correspond to systolic and diastolic behaviors were applied to the tissue model to mimic the optical properties of the tissues. Based on the absorbed ray flux at detectors, the OD and ODR were successfully calculated. The simulation results of optical density ratio occurred at every 20 % interval of SaO2 is presented with maximum error of 2.17 % when comparing it with previous numerical simulation technique (MC model). The findings reveal the potential of the proposed method to be used for extended calibration curve study using other wavelength pair.

  18. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  19. Transit-time flow measurement as a predictor of coronary bypass graft failure at one year angiographic follow-up

    DEFF Research Database (Denmark)

    Lehnert, Per; Møller, Christian H; Damgaard, Sune

    2015-01-01

    on graft vessel type, anastomatic configuration, and coronary artery size. RESULTS: Nine hundred eighty-two coronary anastomoses were performed of which 12% had signs of graft failure at one year angiographic follow-up. In internal mammary arteries (IMAs), analysis showed a 4% decrease in graft failure......BACKGROUND: Transit-time flow measurement (TTFM) is a commonly used intraoperative method for evaluation of coronary artery bypass graft (CABG) anastomoses. This study was undertaken to determine whether TTFM can also be used to predict graft patency at one year postsurgery. METHODS: Three hundred...... forty-five CABG patients with intraoperative graft flow measurements and one year angiographic follow-up were analyzed. Graft failure was defined as more than 50% stenosis including the "string sign." Logistic regression analysis was used to analyze the risk of graft failure after one year based...

  20. Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals.

    Science.gov (United States)

    Zhang, Y; Huang, S L; Wang, S; Zhao, W

    2016-05-01

    The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert-Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of wave detection signals.

  1. Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y., E-mail: thuzhangyu@foxmail.com; Huang, S. L., E-mail: huangsling@tsinghua.edu.cn; Wang, S.; Zhao, W. [State Key Laboratory of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084 (China)

    2016-05-15

    The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert–Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of <1% and thus can act as a universal time-of-flight extraction method for narrowband Lamb wave detection signals.

  2. Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals

    International Nuclear Information System (INIS)

    Zhang, Y.; Huang, S. L.; Wang, S.; Zhao, W.

    2016-01-01

    The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert–Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of <1% and thus can act as a universal time-of-flight extraction method for narrowband Lamb wave detection signals.

  3. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. Cosmological constant problem and renormalized vacuum energy density in curved background

    Energy Technology Data Exchange (ETDEWEB)

    Kohri, Kazunori [Theory Center, IPNS, KEK, Tsukuba 305-0801, Ibaraki (Japan); Matsui, Hiroki, E-mail: kohri@post.kek.jp, E-mail: matshiro@post.kek.jp [The Graduate University of Advanced Studies (Sokendai), Tsukuba 305-0801, Ibaraki (Japan)

    2017-06-01

    The current vacuum energy density observed as dark energy ρ{sub dark}≅ 2.5×10{sup −47} GeV{sup 4} is unacceptably small compared with any other scales. Therefore, we encounter serious fine-tuning problem and theoretical difficulty to derive the dark energy. However, the theoretically attractive scenario has been proposed and discussed in literature: in terms of the renormalization-group (RG) running of the cosmological constant, the vacuum energy density can be expressed as ρ{sub vacuum}≅ m {sup 2} H {sup 2} where m is the mass of the scalar field and rather dynamical in curved spacetime. However, there has been no rigorous proof to derive this expression and there are some criticisms about the physical interpretation of the RG running cosmological constant. In the present paper, we revisit the RG running effects of the cosmological constant and investigate the renormalized vacuum energy density in curved spacetime. We demonstrate that the vacuum energy density described by ρ{sub vacuum}≅ m {sup 2} H {sup 2} appears as quantum effects of the curved background rather than the running effects of cosmological constant. Comparing to cosmological observational data, we obtain an upper bound on the mass of the scalar fields to be smaller than the Planck mass, m ∼< M {sub Pl}.

  5. Feasibility of iFlow color-coding technique in quantitative real-time measurement of hemodynamic changes after transarterial chemoembolization for hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    WANG Yuzhe

    2018-01-01

    Full Text Available Objective To investigate the value of iFlow color-coding technique in quantitative real-time analysis of hemodynamic changes after transarterial chemoembolization (TACE for hepatocellular carcinoma (HCC. Methods A total of 31 patients who were diagnosed with HCC in Shanghai Fifth People′s Hospital from December 2015 to January 2017 were enrolled. No patient underwent surgical operation or ablation. All patients underwent TACE with the same contrast agent, high-pressure injector parameters, and place of angiographic catheter. The iFlow technique was used to generate two-dimensional color-coded images and time-density curve (TDC before and after surgery and measure the opening of the angiographic catheter and the time to peak (TTP of the starting and ending points of the major tumor feeding arteries, as well as the ratio of the areas under the curve (AUC of TDC of tumor tissue and the opening of the angiographic catheter. The paired t-test was used for comparison of continuous data between groups. Results TTP of the major tumor feeding arteries was 4.64±0.49 s before TACE and 5.97±0.84 s after TACE (t=11.57, P<0.01, and there was a significant difference in AUC between the tumor tissue and the opening of the angiographic catheter (0.53±0.15 vs 0.16±0.12, t=25.85, P<0.01. There was no significant difference in TTP between the opening of the angiographic catheter and the major tumor feeding arteries before and after TACE (P>0.05. Before TACE, the TDC of tumor feeding arteries had a shape of “rapid increase-rapid reduction” with relatively high slope and peak value, while after TACE, the TDC had a shape of “increase-flat-reduction” with reductions in slope and peak value. Conclusion The iFlow technique can perform real-time measurement of TTP and TDC of the region of interest and helps with quantitative evaluation of hemodynamic changes in HCC. Therefore, it can provide objective quantitative indices for evaluating the degree of

  6. Transvenous embolization of cavernous sinus dural arteriovenous fistula via angiographic occlusive inferior petrous sinus

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2015-09-01

    Conclusion: Angiographic occlusive IPS of CSDAVF may be related to true occlusion of IPS or patent IPS with compartment of the IPS-CS. There is no statistically significant difference in procedural times for these two different fistula anatomies. Transvenous embolization via angiographic occlusive IPS is a safe and effective method to manage CSDAVFs.

  7. Clinical and angiographic characteristics of patients likely to have vulnerable plaques: analysis from the PROSPECT study.

    Science.gov (United States)

    Bourantas, Christos V; Garcia-Garcia, Hector M; Farooq, Vasim; Maehara, Akiko; Xu, Ke; Généreux, Philippe; Diletti, Roberto; Muramatsu, Takashi; Fahy, Martin; Weisz, Giora; Stone, Gregg W; Serruys, Patrick W

    2013-12-01

    This study sought to determine the clinical and angiographic variables that would identify patients with high-risk "vulnerable" coronary plaques. In the PROSPECT (Providing Regional Observations to Study Predictors of Events in the Coronary Tree) study, in patients successfully treated for acute coronary syndrome (ACS), plaque composition, plaque burden, and minimal luminal area as detected by 3-vessel radiofrequency intravascular ultrasound (IVUS) imaging were associated with an increased risk of developing future events from untreated atherosclerotic lesions (vulnerable plaques). Whether baseline demographic and angiographic findings can be used to identify patients most likely to have vulnerable coronary plaques has not been examined. On the basis of 3-vessel radiofrequency IVUS imaging, patents in the PROSPECT trial were classified in 2 groups according to whether or not one or more untreated high-risk plaques were present, defined as having ≥2 high-risk features (a thin-cap fibroatheroma, plaque burden ≥70%, and/or minimal luminal area ≤4 mm(2)). The high-risk group (those with one or more high-risk lesions) had higher Framingham risk score (7.5 ± 3.4 vs. 6.9 ± 3.3; p = 0.04), more extensive coronary artery disease, and more nonculprit lesion-related cardiovascular events during the 3-year follow-up (hazard ratio: 2.63; 95% confidence interval: 1.62 to 3.66; p < 0.0001). However, demographic factors had poor discrimination in detecting high-risk patients (area under the curve 0.55), and discrimination was only slightly improved when angiographic variables were entered into the model (area under the curve 0.64). Clinical and angiographic characteristics had poor predictive accuracy in identifying patients with untreated high-risk plaques related to future adverse events. This finding highlights the potential value of comprehensive 3-vessel imaging assessment (either invasive or noninvasive) to evaluate plaque phenotype for more accurate risk

  8. Angiographic appearances of rare renal tumours

    International Nuclear Information System (INIS)

    Schmidt, M.; Taenzer, V.

    1980-01-01

    Oncocytomas, called oxyphil proximal tubular adenomas in the Anglo Saxon literature, and benign hypernephromas are non-malignant, usually symptomless, rare tumours belonging to the renal adenomas. Oncocytomas have angiographic appearances sufficiently uniform to permit a tentative diagnosis. Histologically benign hypernephromas do not possess characteristic angiographic appearances and, in the presence of tumour in the renal vein or necrotic avascular areas, must be regarded as potentially malignant. (orig.) [de

  9. Angiographic picture of soft tissue desmoid fibromas

    International Nuclear Information System (INIS)

    Nikitaev, N.S.; Kuznetsova, M.A.

    1987-01-01

    Arteriography was performed in 35 patients with soft tissue desmoid fibromas. Angiographic semiotics of this disease was described. The frequency of detectability of symptoms in the arterial, parenchymatous and venous phases was analyzed. A tumor in the arterial phase was shown to be of normevascular or moderately hypervascular type without noticeable winding of the nutrient arteries, such features of malignancy as lacunae and ''tumor'' vessels being absent. In the parenchymatous phase desmoid tumors were shown to accumulate moderately a contrast substance, a tumor contour at a vast length was ill defined and poorly marked from surrounding tissues. The venous phase was less noticeable and the time of its appearance was usually within normal. In general by most of its parameters the angiographic picture of agressive fibromatosis corresponded to that of benign tumors and could be used for differential diagnosis of desmoid fibromas and some types of tissue sarcomas

  10. Angiographic findings of congenital vascular malformation in soft tissue

    International Nuclear Information System (INIS)

    Choi, Dae Seob; Park, Jae Hyung; Han, Joon Koo; Chung, Jin Wook; Moon, Woo Kyung; Han, Man Chung

    1994-01-01

    We evaluated the clinical, plain radiographic, and angiographic findings of congenital vascular malformation of the soft tissue. Retrospective analysis was performed in 36 patients. Pathological diagnosis was done in 25 patients by surgery and the others were clinically and angiographically diagnosed. On the basis of angiographic findings, we classified the lesions to three groups as arteriovenous malformation (AVM), hemangioma, and venous malformation. In pathologically proven 25 cases, we compared the angiographic diagnosis with the pathologic diagnosis. By angiographic classification, AVM was 13 cases, hemangioma 16 cases, and venous malformation 7 cases. The locations of the lesions were upper extremities in 14 cases, lower extremities in 20 cases, both extremities in 1 case, and back in 1 case. Clinical findings were bruit and thrill in 13 cases(12 AVMs,1 hemangioma) and varicosities in 16 cases(11 AVMs, 3 hemangiomas and 2 venous malformations). The varicosities in AVM were pulsating nature, but not in hemangioma and venous malformation. The concordance rate of the angiographic and pathologic diagnosis was 100%(6/6) in AVM, 71%(10/14) in hemangioma and 60% (3/5) in venous malformation. We think that angiography is an essential study for accurate diagnosis and appropriate treatment of congenital vascular malformation

  11. On the late-time behavior of tracer test breakthrough curves

    Energy Technology Data Exchange (ETDEWEB)

    HAGGERTY, ROY; MCKENNA, SEAN A; MEIGS, LUCY C

    2000-06-12

    The authors investigated the late-time (asymptotic) behavior of tracer test breakthrough curves (BTCs) with rate-limited mass transfer (e.g., in dual or multi-porosity systems) and found that the late-time concentration, c, is given by the simple expression: c = t{sub ad} (c{sub 0}g {minus} m{sub 0}{partial_derivative}g/{partial_derivative}t), for t >> t{sub ad} and t{sub a} >> t{sub ad} where t{sub ad} is the advection time, c{sub 0} is the initial concentration in the medium, m{sub 0} is the 0th moment of the injection pulse; and t{sub a} is the mean residence time in the immobile domain (i.e., the characteristic mass transfer time). The function g is proportional to the residence time distribution in the immobile domain, the authors tabulate g for many geometries, including several distributed (multirate) models of mass transfer. Using this expression they examine the behavior of late-time concentration for a number of mass transfer models. One key results is that if rate-limited mass transfer causes the BTC to behave as a power-law at late-time (i.e., c {approximately} t{sup {minus}k}), then the underlying density function of rate coefficients must also be a power-law with the form a{sup k{minus}}, as a {r_arrow}0. This is true for both density functions of first-order and diffusion rate coefficients. BTCs with k < 3 persisting to the end of the experiment indicate a mean residence time longer than the experiment and possibly infinite, and also suggest an effective rate coefficient that is either undefined or changes as a function of observation time. They apply their analysis to breakthrough curves from Single-Well Injection-Withdrawal tests at the Waste Isolation Pilot Plant, New Mexico.

  12. Angiographic Guidewire with Measuring Markers: Design and Clinical Experience

    International Nuclear Information System (INIS)

    Kamei, Seiji; Ishiguchi, Tsuneo; Murata, Katsuhito; Matsuda, Joe; Ohno, Ryota; Kimura, Junko; Nakamura, Atsushi; Ohno, Kazuko; Kawamura, Toshiki; Ikeda, Mitsuru

    2006-01-01

    Purpose. We have developed an angiographic guidewire with measuring markers to determine accurately how far a guidewire is inserted within a catheter. We investigated whether use of this guidewire reduces the risk of vascular injury and the fluoroscopic time during guidewire manipulations. Methods. Four markers were put on the surface of the guidewire at 80, 100, 110, and 120 cm from the tip. The actual lengths of 54 catheters from seven manufacturers were measured and compared with the nominal lengths. Sixty consecutive patients who underwent angiography were randomized into two groups: in one group guidewires with surface markers were used (marker group) and in the other group, conventional guidewires (control group). For each guidewire insertion, the fluoroscopic time before the guidewire was pushed forward into the vessel lumen was recorded. The number of occasions on which unintentionally the guidewire had already been pushed out of the catheter at the start of fluoroscopy was also evaluated. Results. The actual lengths of all catheters were greater than the nominal lengths by 1.0-11.0 cm. Mean fluoroscopic time for each guidewire insertion was 3.3 sec in the marker group and 5.7 sec in the control group (p < 0.05). Guidewires were unintentionally pushed out of the catheters without fluoroscopy three times (3.6%), in each case in the control group. Conclusion. The guidewire with measuring markers is effective for enhancing safety and in reducing fluoroscopic radiation during angiographic procedures. It is recommended that operators be aware that actual lengths of catheters may vary significantly from the nominal lengths listed; they should be aware of this with any guidewire, but particularly with the angiographic measuring guidewire

  13. Angiographic diagnosis of the carotid artery pseudoaneurysm

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Tan Yinghui; Li Zhongyu; Zhou Zheng

    2004-01-01

    Objective: To create a further understanding of the angiographic features of the carotid artery pseudoaneurysm (CAPA) and to explore the clinical diagnostic value of angiography. Methods: Sixteen cases of CAPA with clinical and angiographic data were analyzed retrospectively. The angiographic appearances in all of the patients were observed dynamically and precisely with a double blind method by two experienced radiologists together and formed a consensus interpretation. Results: Angiography provided a definite diagnosis for all cases. The parent arteries included the common carotid artery (1 case), common carotid artery bifurcation (9 cases), internal carotid artery (5 cases) and external carotid artery (1 case). The angiographic features of the CAPA were: All cases showed the contrast media retension in the aneurysms; turbulent flow within aneurysm in 9 cases; the 'jetting sign' at the leak of the parent artery in 7 cases; increase angulation of the bifurcation of internal and external carotid arteries in 12 cases. Conclusions: Angiography is the most valuable examination method in diagnosis of CAPA, and it can not only provide definite diagnosis, but also play an important role in selection of therapeutic plan. (authors)

  14. Clinical and angiographic outcomes after intracoronary bare-metal stenting.

    Directory of Open Access Journals (Sweden)

    I-Chang Hsieh

    Full Text Available BACKGROUND: Data from a large patient population regarding very long-term outcomes after BMS implantation are inadequate. This study aimed to evaluate the very long-term (8-17 years clinical and long-term (3-5 years angiographic outcomes after intracoronary bare-metal stenting (BMS. METHODS AND RESULTS: From the Cardiovascular Atherosclerosis and Percutaneous TrAnsluminal INterventions (CAPTAIN registry, a total of 2391 patients with 2966 lesions treated with 3190 BMSs between November 1995 and May 2004 were evaluated. In total, 1898 patients with 2364 lesions, and 699 patients with 861 lesions underwent 6-month and 3- to 5- year angiographic follow-up, respectively. During a mean follow-up period of 149 ± 51 months, 18.6% of the patients died (including 10.8% due to cardiac death, 6.1% developed reinfarction, 16.2% had target lesion revascularization (including 81% of the patients within the first year, 14.5% underwent new lesion stenting (including 72% of the patients after 3 years, 2.4% underwent coronary bypass surgery, and 1.6% had definite stent thrombosis. The overall cardiovascular event-free survival rate was 58.5%. The 6-month angiographic study indicated a 20% restenosis rate. The minimal luminal diameter increased from 0.65 ± 0.44 mm to 3.02 ± 0.46 mm immediately after stenting, decreased to 2.06 ± 0.77 mm at the 6-month follow-up, and increased to 2.27 ± 0.68 mm at the 3- to 5-year follow-up. CONCLUSIONS: This study provides clinical and angiographic results from a large population of patients who underwent BMS implantations after a long-term follow-up period (149 ± 51 months. The progression of coronary atherosclerosis developed over time, and presented with new lesion required stent implantation. The follow-up angiographic findings reconfirmed the late and sustained improvement in luminal diameter between 6 months and 3-5 years.

  15. Angiographic features of rapidly involuting congenital hemangioma (RICH)

    Energy Technology Data Exchange (ETDEWEB)

    Konez, Orhan; Burrows, Patricia E. [Department of Radiology, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Mulliken, John B. [Division of Plastic Surgery, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Fishman, Steven J. [Department of Pediatric Surgery, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Kozakewich, Harry P.W. [Department of Pathology, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States)

    2003-01-01

    Rapidly involuting congenital hemangioma (RICH) is a recently recognized entity in which the vascular tumor is fully developed at birth and undergoes rapid involution. Angiographic findings in two infants with congenital hemangioma are reported and compared with a more common postnatal infantile hemangioma and a congenital infantile fibrosarcoma. Congenital hemangiomas differed from infantile hemangiomas angiographically by inhomogeneous parenchymal staining, large and irregular feeding arteries in disorganized patterns, arterial aneurysms, direct arteriovenous shunts, and intravascular thrombi. Both infants had clinical evidence of a high-output cardiac failure and intralesional bleeding. This congenital high-flow vascular tumor is difficult to distinguish angiographically from arteriovenous malformation and congenital infantile fibrosarcoma. (orig.)

  16. A comparison of entrance skin dose delivered by clinical angiographic c-arms using the real-time dosimeter: the MOSkin

    International Nuclear Information System (INIS)

    Thorpe, Nathan K.; Cutajar, Dean; Lian, Cheryl; Rosenfeld, Anatoly; Pitney, Mark; Friedman, Daniel; Perevertaylo, Vladimir

    2016-01-01

    Coronary angiography is a procedure used in the diagnosis and intervention of coronary heart disease. The procedure is often considered one of the highest dose diagnostic procedures in clinical use. Despite this, there is minimal use of dosimeters within angiographic catheterisation laboratories due to challenges resulting from their implementation. The aim of this study was to compare entrance dose delivery across locally commissioned c-arms to assess the need for real-time dosimetry solutions during angiographic procedures. The secondary aim of this study was to establish a calibration method for the MOSkin dosimeter that accurately produces entrance dose values from the clinically sampled beam qualities and energies. The MOSkin is a real-time dosimeter used to measure the skin dose delivered by external radiation beams. The suitability of the MOSkin for measurements in the angiographic catheterisation laboratory was assessed. Measurements were performed using a 30 × 30 × 30cm 3 PMMA phantom positioned at the rotational isocenter of the c-arm gantry. The MOSkin calibration factor was established through comparison of the MOSkin response to EBT2 film response. Irradiation of the dosimeters was performed using several clinical beam qualities ranging in energy from 70 to 105 kVp. A total of four different interventional c-arm machines were surveyed and compared using the MOSkin dosimeter. The phantom was irradiated from a normal angle of incidence using clinically relevant protocols, field sizes and source to image detector distance values. The MOSkin was observed to be radiotranslucent to the c-arm beam in all clinical environments. The MOSkin response was reproducible to within 2 % of the average value across repeated measurements for each beam setting. There were large variations in entrance dose delivery to the phantom between the different c-arm machines with the highest observed cine-acquisition entrance dose rate measuring 326 % higher than the lowest

  17. Intracranial meningeal masson's hemangioma: CT and angiographic features

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Chi, Je Gen; Han, Man Chung; Cho, Byung Kyu; Kim, Hyun Jip

    1985-01-01

    Masson's hemangioma is a rare benign vascular condition with a papillary intravascular endothelial proliferation which may appear either as a primary form as a secondary form in a pre-existing vascular process. CT and angiographic features of 2 cases with Masson's hemangioma were presented. Both of them were located extra-axially in the posterior fossa. CT findings were not specific in both cases; One showed homogeneously enhancing mass, simulating meningioma. And the other demonstrated a multiocular rim enhancing mass. However, the angiographic features were rather characteristic; Both cases showed persistent vascular poolings of contrast media which were supplied form the meningeal vessels. Angiographic differential diagnosis of similar lesions in the posterior fossa is discussed

  18. Clinical application of digital angiographic system DIGITEX2400

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki (Shimadzu Corp., Kyoto (Japan))

    1992-10-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author).

  19. Clinical application of digital angiographic system DIGITEX2400

    International Nuclear Information System (INIS)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki

    1992-01-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author)

  20. Quantitative assessment of angiographic perfusion reduction using color-coded digital subtraction angiography during transarterial chemoembolization.

    Science.gov (United States)

    Wang, Ji; Cheng, Jie-Jun; Huang, Kai-Yi; Zhuang, Zhi-Guo; Zhang, Xue-Bin; Chi, Jia-Chang; Hua, Xiao-Lan; Xu, Jian-Rong

    2016-03-01

    The aim of this study was to develop a quantitative measurement of perfusion reduction using color-coded digital subtraction angiography (ccDSA) to monitor intra-procedural arterial stasis during TACE. A total number of 35 patients with hepatocellular carcinoma who had undergone TACE were enrolled into the study. Pre- and post-two-dimensional digital subtraction angiography scans were conducted with same protocol and post-processed with ccDSA prototype software. Time-contrast-intensity (CI[t]) curve was obtained by region-of-interest (ROI) measurement on the generated ccDSA image. Quantitative 2D perfusion parameters time to peak, area under the curve (AUC), maximum upslope, and contrast intensity peak (CI-Peak) derived from the ROI-based CI[t] curve for pre- and post-TACE were evaluated to assess the reduction of antegrade blood flow and tumor blush. Relationships between 2D perfusion parameters, subjective angiographic chemoembolization endpoint (SACE) scale, and clinical outcomes were analyzed. Area normalized AUC and CI-Peak revealed significant reduction after the TACE (P SACE level III and a reduction ranging from 60% to 70% was equivalent to SACE level IV. For intermediate reduction (SACE level III), better tumor response was found after TACE rather than a higher reduction (SACE level IV). ccDSA application provides an objective approach to quantify the perfusion reduction and subjectively evaluate the arterial stasis of antegrade blood flow and tumor blush caused by TACE.

  1. Quaternion wave equations in curved space-time

    Science.gov (United States)

    Edmonds, J. D., Jr.

    1974-01-01

    The quaternion formulation of relativistic quantum theory is extended to include curvilinear coordinates and curved space-time in order to provide a framework for a unified quantum/gravity theory. Six basic quaternion fields are identified in curved space-time, the four-vector basis quaternions are identified, and the necessary covariant derivatives are obtained. Invariant field equations are derived, and a general invertable coordinate transformation is developed. The results yield a way of writing quaternion wave equations in curvilinear coordinates and curved space-time as well as a natural framework for solving the problem of second quantization for gravity.

  2. Characterizing time series via complexity-entropy curves

    Science.gov (United States)

    Ribeiro, Haroldo V.; Jauregui, Max; Zunino, Luciano; Lenzi, Ervin K.

    2017-06-01

    The search for patterns in time series is a very common task when dealing with complex systems. This is usually accomplished by employing a complexity measure such as entropies and fractal dimensions. However, such measures usually only capture a single aspect of the system dynamics. Here, we propose a family of complexity measures for time series based on a generalization of the complexity-entropy causality plane. By replacing the Shannon entropy by a monoparametric entropy (Tsallis q entropy) and after considering the proper generalization of the statistical complexity (q complexity), we build up a parametric curve (the q -complexity-entropy curve) that is used for characterizing and classifying time series. Based on simple exact results and numerical simulations of stochastic processes, we show that these curves can distinguish among different long-range, short-range, and oscillating correlated behaviors. Also, we verify that simulated chaotic and stochastic time series can be distinguished based on whether these curves are open or closed. We further test this technique in experimental scenarios related to chaotic laser intensity, stock price, sunspot, and geomagnetic dynamics, confirming its usefulness. Finally, we prove that these curves enhance the automatic classification of time series with long-range correlations and interbeat intervals of healthy subjects and patients with heart disease.

  3. Angiographic diagnosis and treatment of gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Sung, Kyu Bo; Koo, Kyung Hoi; Bae, Tae Young; Chung, Eun Chul; Han, Man Chung

    1986-01-01

    Diagnostic angiographic evaluations were done in 33 patients with gastrointestinal bleeding for recent 5 years at Department of Radiology, Seoul National University Hospital. On 11 patients of them, therapeutic interventional procedures were made and the results were analysed. 1. In a total of 33 cases, there were 18 cases of upper GI bleeding and 15 cases of lower GI bleeding. The most frequent causes were peptic ulcer in the former and intestinal typhoid fever in the latter. 2. Bleeding sites were localized angiographically in 28 cases, so the detection rate was 85%. Four of the five angiographically negative cases were lower GI bleeding cases. 3. The most frequent bleeding site was left gastric artery (7/33). The next was ileocecal branch of superior mesenteric artery (6/33). 4. Among the 11 interventional procedures, Gelfoam embolization was done in 7 cases and Vasopressin infusion was tried in 4 cases. They were successful in 4 and 3 cases, suggesting 57% and 47% success rates respectively.

  4. Angiographic diagnosis and treatment of gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Sung, Kyu Bo; Koo, Kyung Hoi; Bae, Tae Young; Chung, Eun Chul; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-02-15

    Diagnostic angiographic evaluations were done in 33 patients with gastrointestinal bleeding for recent 5 years at Department of Radiology, Seoul National University Hospital. On 11 patients of them, therapeutic interventional procedures were made and the results were analysed. 1. In a total of 33 cases, there were 18 cases of upper GI bleeding and 15 cases of lower GI bleeding. The most frequent causes were peptic ulcer in the former and intestinal typhoid fever in the latter. 2. Bleeding sites were localized angiographically in 28 cases, so the detection rate was 85%. Four of the five angiographically negative cases were lower GI bleeding cases. 3. The most frequent bleeding site was left gastric artery (7/33). The next was ileocecal branch of superior mesenteric artery (6/33). 4. Among the 11 interventional procedures, Gelfoam embolization was done in 7 cases and Vasopressin infusion was tried in 4 cases. They were successful in 4 and 3 cases, suggesting 57% and 47% success rates respectively.

  5. Effect of glycoprotein IIb/IIIa receptor inhibition on angiographic complications during percutaneous coronary intervention in the ESPRIT trial.

    Science.gov (United States)

    Blankenship, J C; Tasissa, G; O'Shea, J C; Iliadis, E A; Bachour, F A; Cohen, D J; Lui, H K; Mann, T; Cohen, E; Tcheng, J E

    2001-09-01

    We sought to determine whether eptifibatide decreases the incidence of in-laboratory angiographic complications and to determine the relationship of angiographically evident complications to elevations of creatine kinase-MB (CK-MB) enzyme levels during percutaneous coronary intervention. In the Enhanced Suppression of the Platelet IIb/IIIa Receptor with Integrilin Therapy (ESPRIT) trial, eptifibatide during coronary intervention was associated with decreased ischemic complications at 48 h and 30 days. Patients (n = 2,064) were randomized to placebo versus eptifibatide (two 180 microg/kg boluses 10 min apart and as a continuous infusion of 2 microg/kg per min) during percutaneous coronary stenting. Angiographic complications including major dissection, distal embolization, residual thrombus, abrupt closure, residual stenosis >50% and side-branch occlusion were prospectively recorded by the operator. Creatine kinase-MB levels were measured after the procedure and every 6 h thereafter. The incidence of angiographic complications and CK-MB elevation was determined for eptifibatide versus placebo groups. Eptifibatide-treated patients demonstrated nonsignificant trends toward fewer angiographic complications (10 vs. 12% for placebo patients, p = 0.13) and, for patients with angiographic complications, fewer subsequent CK-MB elevations (43 vs. 50% for placebo patients, p = 0.31). In patients without any angiographic complications, the incidence of CK-MB elevation >3 times the normal was 7% with placebo and 4% with eptifibatide (p = 0.003). Eptifibatide during nonurgent coronary stent intervention only minimally (and insignificantly) reduces the incidence of angiographic complications and subsequent CK-MB elevations in patients developing an angiographic complication. The greater effect is to reduce myocardial infarction in patients undergoing otherwise uneventful coronary stent implantation as well as in the overall study population.

  6. Time to Angiographic Reperfusion and Clinical Outcome after Acute Ischemic Stroke in the Interventional Management of Stroke Phase III (IMS III) Trial: A Validation Study

    Science.gov (United States)

    Khatri, Pooja; Yeatts, Sharon D.; Mazighi, Mikael; Broderick, Joseph P.; Liebeskind, David S.; Demchuk, Andrew M.; Amarenco, Pierre; Carrozzella, Janice; Spilker, Judith; Foster, Lydia D.; Goyal, Mayank; Hill, Michael D.; Palesch, Yuko Y.; Jauch, Edward C.; Haley, E. Clarke; Vagal, Achala; Tomsick, Thomas A.

    2014-01-01

    BACKGROUND The IMS III Trial did not demonstrate clinical benefit of the endovascular approach compared to IV rt-PA alone for moderate or severe ischemic strokes (NIHSS≥8) enrolled within three hours of stroke onset. Late reperfusion of tissue that is no longer salvageable may be one explanation, as suggested by prior exploratory studies showing an association between time to reperfusion and good clinical outcome. We sought to validate this relationship in the large-scale IMS III trial, and consider its implications for future endovascular trials. METHODS The analysis consisted of the endovascular cohort with proximal arterial occlusions in the anterior circulation that achieved angiographic reperfusion (TICI 2–3) during the endovascular procedure (within 7 hours from the onset of symptoms). Logistic regression was used to model good clinical outcome (90-day modified Rankin 0–2) as a function of the time to reperfusion, and prespecified variables were considered for adjustment. FINDINGS Among 240 proximal vessel occlusions, angiographic reperfusion (TICI 2–3) was achieved in 182 (76%). Mean time to reperfusion was 325 minutes (range 180–418 minutes). Longer time for reperfusion was associated with a decreased likelihood of good clinical outcome (RR [95% CI] for every 30 minute delay: unadjusted 0·85 [0·77–0·94]; adjusted 0·88 [0·80–0·98]). INTERPRETATION We confirm that delay in time to angiographic reperfusion leads to a decreased likelihood of good clinical outcome. Achieving rapid reperfusion may be critical for the successes of future acute endovascular trials. FUNDING: NIH/NINDS (study sponsor), Genentech Inc. (study drug - intra-arterial t-PA), EKOS Corp. (device), Concentric Inc. (device), Cordis Neurovascular, Inc. (device), and Boehringer Ingelheim (European Investigator Meeting support). PMID:24784550

  7. Functional methods for arbitrary densities in curved spacetime

    International Nuclear Information System (INIS)

    Basler, M.

    1993-01-01

    This paper gives an introduction to the technique of functional differentiation and integration in curved spacetime, applied to examples from quantum field theory. Special attention is drawn on the choice of functional integral measure. Referring to a suggestion by Toms, fields are choosen as arbitrary scalar, spinorial or vectorial densities. The technique developed by Toms for a pure quadratic Lagrangian are extended to the calculation of the generating functional with external sources. Included are two examples of interacting theories, a self-interacting scalar field and a Yang-Mills theory. For these theories the complete set of Feynman graphs depending on the weight of variables is derived. (orig.)

  8. Thermoluminescence glow curves of irradiated PMMA and low density polyethylene

    International Nuclear Information System (INIS)

    Matsuda, Koji; Nakase, Yoshiaki; Kumakiri, Yasuhito; Tsuji, Yoshio.

    1985-03-01

    Light emission from polymers is observed when polymers preirradiated with ionizing radiation at low temperature are heated gradually. The light emission is supposedly resulted from recombination of electrons with active centers produced in polymers or from some other processes involving charge transfer, but no definite explanation has been given at present on the thermoluminescent centers. This report describes our studies on the effects of impurities contained in polymers and pressure of ambient gases on the thermoluminescent glow curve of PMMA and low density polyethylene, which are often used for plastic film dosimeters. In the glow curve of PMMA, only one peak was observed at 110 K in an H 2 or He atmosphere at 760 Torr, but the intensity of the peak decreased with decreasing the H 2 or He gas pressure. At 10 -5 Torr H 2 or He atmosphere the peak disappered, and two sharp peaks appeared in the temperature range from 200 to 250 K. On the other hand, in the glow curve of low density polyethylene, three peaks were observed at 120 K, 180 K and 250 K in the presence of H 2 or He gas at 760 Torr. The effects of pressure of ambient gases and impurities in the polyethylene on these peaks indicate that the peak at 120 K is due to luminescent center produced on the surface or just below the surface of the matrix by collision of excited atoms or molecules of gases with polymer molecules, the peak at 120 K is originated from impurities in the matrix, and the peak at 250 0 K corresponds to luminescent center produced in polyethylene matrix. (author)

  9. The selective angiographic diagnosis and endovascular embolization treatment of severe epistaxis

    International Nuclear Information System (INIS)

    Zhang Xiquan; Lu Yonghong; Sun Jinghua; Guo Deqiang; Li Yuzhen; Wei Aihua

    2002-01-01

    Objective: To evaluate selective angiographic diagnosis and embolization of severe epistaxis in 57 cases. Methods: 41 cases with spontaneous haemorrhage, 11 cases with traumatic haemorrhage, 3 cases with haemorrhage of nasopharyngeal fibroangioma, and 2 case with haemorrhage of nasopharyngeal carcinoma were included in the study. Selective angiographic diagnosis and embolization of epistaxis were performed with absorbable gelatin sponge or balloon or spring coil by using Seldinger's method. Results: 59 procedure of angiographic diagnosis and embolization were performed in 57 cases. Both maxillaris internal artery embolization was performed in 6 cases. After embolization, satisfactory results were achieved immediately in 55 cases. After 6 months to 2 years' follow-up, no haemorrhage recurred. In 4 cases with traumatic haemorrhage in the face, simple maxillaris internal artery embolization was performed in 2 cases. Conclusion: Selective angiographic diagnosis and embolization are safe, effective, and successful method of choices in the treatment of severe epistaxis

  10. Characterization of time series via Rényi complexity-entropy curves

    Science.gov (United States)

    Jauregui, M.; Zunino, L.; Lenzi, E. K.; Mendes, R. S.; Ribeiro, H. V.

    2018-05-01

    One of the most useful tools for distinguishing between chaotic and stochastic time series is the so-called complexity-entropy causality plane. This diagram involves two complexity measures: the Shannon entropy and the statistical complexity. Recently, this idea has been generalized by considering the Tsallis monoparametric generalization of the Shannon entropy, yielding complexity-entropy curves. These curves have proven to enhance the discrimination among different time series related to stochastic and chaotic processes of numerical and experimental nature. Here we further explore these complexity-entropy curves in the context of the Rényi entropy, which is another monoparametric generalization of the Shannon entropy. By combining the Rényi entropy with the proper generalization of the statistical complexity, we associate a parametric curve (the Rényi complexity-entropy curve) with a given time series. We explore this approach in a series of numerical and experimental applications, demonstrating the usefulness of this new technique for time series analysis. We show that the Rényi complexity-entropy curves enable the differentiation among time series of chaotic, stochastic, and periodic nature. In particular, time series of stochastic nature are associated with curves displaying positive curvature in a neighborhood of their initial points, whereas curves related to chaotic phenomena have a negative curvature; finally, periodic time series are represented by vertical straight lines.

  11. Neutron Gauge Calibration Curve as Affected by Chloride Concentration and Bulk Density of Loam Soil

    International Nuclear Information System (INIS)

    AL-Hasani, A.A.; Fahad, A.A.; Shihab, R.M.

    2010-01-01

    chloride concentration and bulk density are considered among important factors affecting calibration curve of neutron gauge in the soil.The aim of this study was to investigate the effect of chloride concentration and bulk density of a loam soil on neutron gauge calibration curve.Sufficient amount of loam soil was air dried screened through a 2 mm sieve,and divided into three equal portions.Sodium chloride of 2.5 and 6.6g kg'-1 soil was added to the first and second portions,respectively.The third portion was left as a control.The soil then moistened and mixed well to make volumetric water content within the range of 0.01 to 0.24 cm 3 cm - 3. The moist soil was packed into an iron drum 0.80 m diameter and 1.00 m height to obtain bulk densities of 1.10 and 1.30 to 1.60 Mg m - 3 for uncompacted soil,respectively.Access tube 0.05 m inner diameter was installed in the center of the drum.Three readings from CPN 503 neutron gauge were taken at each 0.15,0.30, 0.45,and 0.75 m depth.Results indicated that the count (counts/standard count) for an aqueous solution decreased with the increase in chloride concentration.Similarly, the slope of the linear calibration curves of the investigated soil decreased with the increase in chloride concentration.Shifting of the curves was 9 to 10%for the uncompacted soil, whereas it was 12 to 14 % for the compacted of low and high concentration of chloride, respectively . Results of changing bulk density always reduced the slope value as compared with the uncorrected count ratio.

  12. A comparison of chemoembolization endpoints using angiographic versus transcatheter intraarterial perfusion/MR imaging monitoring.

    Science.gov (United States)

    Lewandowski, Robert J; Wang, Dingxin; Gehl, James; Atassi, Bassel; Ryu, Robert K; Sato, Kent; Nemcek, Albert A; Miller, Frank H; Mulcahy, Mary F; Kulik, Laura; Larson, Andrew C; Salem, Riad; Omary, Reed A

    2007-10-01

    Transcatheter arterial chemoembolization (TACE) is an established treatment for unresectable liver cancer. This study was conducted to test the hypothesis that angiographic endpoints during TACE are measurable and reproducible by comparing subjective angiographic versus objective magnetic resonance (MR) endpoints of TACE. The study included 12 consecutive patients who presented for TACE for surgically unresectable HCC or progressive hepatic metastases despite chemotherapy. All procedures were performed with a dedicated imaging system. Angiographic series before and after TACE were reviewed independently by three board-certified interventional radiologists. A subjective angiographic chemoembolization endpoint (SACE) classification scheme, modified from an established angiographic grading system in the cardiology literature, was designed to assist in reproducibly classifying angiographic endpoints. Reproducibility in SACE classification level was compared among operators, and MR imaging perfusion reduction was compared with SACE levels for each observer. Twelve patients successfully underwent 15 separate TACE sessions. SACE levels ranged from I through IV. There was moderate agreement in SACE classification (kappa = 0.46 +/- 0.12). There was no correlation between SACE level and MR perfusion reduction (r = 0.16 for one operator and 0.02 for the other two). Angiographic endpoints during TACE vary widely, have moderate reproducibility among operators, and do not correlate with functional MR imaging perfusion endpoints. Future research should aim to determine ideal angiographic and functional MR imaging endpoints for TACE according to outcome measures such as imaging response, pathologic response, and survival.

  13. Angiographic findings of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Han, Man Chung; Cho, Byung Jae; Huh, Seung Jae; Bae, Sang Hoon; Kim, Ung Jin; Kim, Chung Yong; Kim, Noe Kyeong [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1985-12-15

    From March 1977 to July 1979, 69 cases of angiograms of hepatocellular carcinoma were observed in Seoul National University Hospital. The findings of selective celiac and/or hepatic arteriography in total 69 cases of confirmed hepatocellular carcinoma, with clinical and laboratory findings, were analyzed. The summarized results are as follows; 1. Among 69 cases od hepatoma, 62 were male and 7 were female with sex ratio of 8.9 : 1. Peak incidence is 5th to 7th decades (72.5%). Epigastric pain, indigestion, and palpable mass in right upper quadrant were common symptoms and sign. Laboratory findings showed elevated serum alkaline phosphatase more than 5 Bodansky unit in 75.4%. Alpha-feto protein was positive in 65.2% of all the patients. 2 All 69 cases were classified into 31 cases of massive type, 22 cases of diffuse type, and 16 cases of nodular type, in accordance with angiographic gross anatomy. The frequency of angiographic findings were hypervascularities and tumor vessels (100%), tumor stainings (98.5%), arteriovenous shunt (71.0%), displacement of intrahepatic arteries (66.7%), vascular lakes and channel (59.4%). Encasement of hepatic artery and portal vein regurgitation was respectively 4 cases. Tumor mass in portal vein were 6 cases and tumor mass in hepatic vein was 1 case. 3. Intraarterial infusion of 5-FU was performed in 15 hepatoma patients, and the results were that angiographic improvement was demonstrated in 3 cases, no improvement in 8 cases, and incomplete infusion in 4 cases. 4. The selective celiac and/or hepatic angiograms are excellent diagnostic tools as well as therapeutic management for intraarterial infusion of anticancerous drugs.

  14. Angiographic findings of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Han, Man Chung; Cho, Byung Jae; Huh, Seung Jae; Bae, Sang Hoon; Kim, Ung Jin; Kim, Chung Yong; Kim, Noe Kyeong

    1985-01-01

    From March 1977 to July 1979, 69 cases of angiograms of hepatocellular carcinoma were observed in Seoul National University Hospital. The findings of selective celiac and/or hepatic arteriography in total 69 cases of confirmed hepatocellular carcinoma, with clinical and laboratory findings, were analyzed. The summarized results are as follows; 1. Among 69 cases od hepatoma, 62 were male and 7 were female with sex ratio of 8.9 : 1. Peak incidence is 5th to 7th decades (72.5%). Epigastric pain, indigestion, and palpable mass in right upper quadrant were common symptoms and sign. Laboratory findings showed elevated serum alkaline phosphatase more than 5 Bodansky unit in 75.4%. Alpha-feto protein was positive in 65.2% of all the patients. 2 All 69 cases were classified into 31 cases of massive type, 22 cases of diffuse type, and 16 cases of nodular type, in accordance with angiographic gross anatomy. The frequency of angiographic findings were hypervascularities and tumor vessels (100%), tumor stainings (98.5%), arteriovenous shunt (71.0%), displacement of intrahepatic arteries (66.7%), vascular lakes and channel (59.4%). Encasement of hepatic artery and portal vein regurgitation was respectively 4 cases. Tumor mass in portal vein were 6 cases and tumor mass in hepatic vein was 1 case. 3. Intraarterial infusion of 5-FU was performed in 15 hepatoma patients, and the results were that angiographic improvement was demonstrated in 3 cases, no improvement in 8 cases, and incomplete infusion in 4 cases. 4. The selective celiac and/or hepatic angiograms are excellent diagnostic tools as well as therapeutic management for intraarterial infusion of anticancerous drugs.

  15. Persistent sciatic artery: clinical, embryologic, and angiographic features

    International Nuclear Information System (INIS)

    Mandell, V.S.; Jaques, P.F.; Delaney, D.J.; Oberheu, V.

    1985-01-01

    The persistent sciatic artery is a rare but interesting and clinically pertinent vascular anomaly that may present as a buttock aneurysm or as an ischemic or embolic disease. Its correct angiographic diagnosis depends on recognition of an abnormally large internal iliac artery, appropriate injection and adequate timing to fill and follow flow into the large vessel, and recognition and differentiation of the tapering superficial femoral artery from routine occlusive disease so that an accurate picture of lower leg runoff is provided

  16. The Surface Density Profile of the Galactic Disk from the Terminal Velocity Curve

    Science.gov (United States)

    McGaugh, Stacy S.

    2016-01-01

    The mass distribution of the Galactic disk is constructed from the terminal velocity curve and the mass discrepancy-acceleration relation. Mass models numerically quantifying the detailed surface density profiles are tabulated. For R0 = 8 kpc, the models have stellar mass 5 spiral galaxy that obeys scaling relations like the Tully-Fisher relation, the size-mass relation, and the disk maximality-surface brightness relation. The stellar disk is maximal, and the spiral arms are massive. The bumps and wiggles in the terminal velocity curve correspond to known spiral features (e.g., the Centaurus arm is a ˜50% overdensity). The rotation curve switches between positive and negative over scales of hundreds of parsecs. The rms amplitude { }1/2≈ 14 {km} {{{s}}}-1 {{kpc}}-1, implying that commonly neglected terms in the Jeans equations may be nonnegligible. The spherically averaged local dark matter density is ρ0,DM ≈ 0.009 {M}⊙ {{pc}}-3 (0.34 {GeV} {{cm}}-3). Adiabatic compression of the dark matter halo may help reconcile the Milky Way with the c-V200 relation expected in ΛCDM while also helping to mitigate the too-big-to-fail problem, but it remains difficult to reconcile the inner bulge/bar-dominated region with a cuspy halo. We note that NGC 3521 is a near twin to the Milky Way, having a similar luminosity, scale length, and rotation curve.

  17. Matter fields in curved space-time

    International Nuclear Information System (INIS)

    Viet, Nguyen Ai; Wali, Kameshwar C.

    2000-01-01

    We study the geometry of a two-sheeted space-time within the framework of non-commutative geometry. As a prelude to the Standard Model in curved space-time, we present a model of a left- and a right- chiral field living on the two sheeted-space time and construct the action functionals that describe their interactions

  18. 3D CT cerebral angiography technique using a 320-detector machine with a time–density curve and low contrast medium volume: Comparison with fixed time delay technique

    International Nuclear Information System (INIS)

    Das, K.; Biswas, S.; Roughley, S.; Bhojak, M.; Niven, S.

    2014-01-01

    Aim: To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Materials and methods: Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time–density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Results: Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having “good” arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Conclusion: Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement

  19. Usefulness of measurement of circulation time using MgSO4 : correlation with time-density curve using electron beam computed tomography

    International Nuclear Information System (INIS)

    Kim, Byung Ki; Lee, Hui Joong; Lee, Jong Min; Kim, Yong Joo; Kang, Duck Sik

    1999-01-01

    To determine the usefulness of MgSO 4 for measuring the systemic circulation time. Systemic circulation time, defined as elapsed time from the injection of MgSO 4 solution to the point of pharyngeal burning sensation, was measured in 63 volunteers. MgSO 4 was injected into a superficial vein of an upper extremity. Using dynamic electron beam computed tomography at the level of the abdominal aorta and celiac axis, a time-intensity curve was plotted, and for these two locations, maximal enhancement time was compared. For 60 of the 63 subjects, both systemic circulation time and maximal enhancement time were determined. Average systemic circulation time was 17.4 (SD:3.6) secs. and average maximal enhancement times at the level of the abdominal aorta and celiac axis were 17.5 (SD:3.0) secs. and 18.5 (SD:3.2) secs., respectively. Correlation coefficients between systemic circulation time and maximal enhancement time for the abdominal aorta and celiac axis were 0.73 (p 4 injection and maximal enhancement time for the abdominal aorta showed significant correlation. Thus, to determine the appropriate scanning time in contrast-enhanced radiological studies, MgSO 4 can be used instead of a test bolus study

  20. Accessory left gastric artery: angiographic anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Soo; Lim, Hyung Guhn; Kim, Hong Soo; Jeon, Doo Sung [Presbyterian Medical Center, Chunju (Korea, Republic of); Chung, Jin Wook; Park, Jae Hyung [College of Medicine and the Institute of Radiation Medicine, Seoul National University, Seoul (Korea, Republic of); Song, Soon Young [Myongji Hospital, College of Medicine, Kwandong University, Seoul (Korea, Republic of)

    2000-09-01

    To evaluate the angiographic anatomy of the accessory left gastric artery (accLGA). We evaluated the angiographic findings of the accLGA in 50 patients (Angiostar; Siemens, Erlangen, Germany). Performing celiac and selective angiography in 50 and 34 patients, respectively. By means of celiac angiography, (1) site of origin, (2) anatomical course, (3) diameter, (4) degree of tortuosity, and (5) distal tapering were evaluated, while selective angiography was used to determine (1) arterial branching, (2) area of blood supply, and (3) patterns of gastric wall stain. Celiac angiography showed that the accLGA arose from the left hepatic artery (LHA) in 45 cases (90%) and from the proper hepatic artery in five (10%). If the accLGA arose from the LHA, its origin entirely depended on the branching pattern of the latter. It always arose from the lateral branch of the LHA furthest to the left and uppermost, and proximal to its umbilical point. The most common anatomical course of the accLGA, seen in 27 cases (54%), was between the S2 and S3 segmental branch. The diameter and degree of tortuosity of the accLGA were similar to those of adjacent intrahepatic branches in 21 (42%) and 33 cases (66%), respectively. The degree of tapering was less than that of adjacent intrahepatic vessel in 28 (56%). Selective angiography demonstrated esophageal branching of the acc LGA in 27 cases (79%), inferior phrenic arterial branching in three (9%), a mediastinal branch in one (3%), and hypervascularity of the lung in one (3%). In 15 cases (44%), bifurcation of the accLGA was recognized. The vascular territory of the accLGA was the gastric fundus together with the distal esophagus in 21 cases (62%), mainly the gastric fundus in six (18%), and mainly the distal esophagus in four (12%). The pattern of gastric mucosal stain was curvilinear wall in 31 cases (91%) and nodular in three (9%). A knowledge of the angiographic anatomy of the accLGA facilitates accurate recognition of this artery on

  1. A simple digital subtraction angiographic instrument

    International Nuclear Information System (INIS)

    Ando, Hiroshi; Kobayashi, Tsuyoshi; Imai, Yutaka; Yanagishita, Akira

    1983-01-01

    A digital subtraction angiographic instrument was manufactured using a conventional x-ray TV for gastrointestinal series and a computer for processing of nuclear medical data. The results of visualization of the aorta and its primary branches were reviewed with demonstrable cases. (Chiba, N.)

  2. Effect of transcatheter arterial embolization according to angiographic findings in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Wang, Chi Hyung; Shim, Hyung Jin; Lee, Jong Ik; Yu, Hyun; Kim, Young Goo; Lee, Jong Beum; Kim, Kun Sang

    1994-01-01

    The purpose of this study is to assess the effect of Transcatheter Arterial Embolization(TAE) according to angiographic findings in hepatocellular carcinoma. We retrospectively reviewed 50 cases who received TAE for unresectable hepatocellular carcinoma. We analyzed the angiographic findings which were correlated with the effect of TAE. The common angiographic findings of the hepatocellular carcinoma were tumor staining, neo vascularity and enlargement of feeding artery. These angiographic findings were classified into grade 0, +1, +2. Effect of TAE were classified into five patterns; good response, partial response, minimal response, no response and more aggravation. In grading of tumor staining, among 50 cases, the grade 0, +1, +2 were seen in 1 case(2%), 14 cases(28%), 35 cases(70%) each. In grading of enlargement of feeding artery, the grade 0, +1, +2 were seen in 7 cases(14%), 19 cases(38%), 24 cases(48%) each. In grading of neo vascularity, the grade 0, +1, +2 were seen in 6 cases(12%), 15 cases(30%), 29 cases(58%) each. This study showed that the higher grade of angiographic finding, the better effect of TAE. A statistically significant difference was found (P<0.005). But the TAE was not effective in some cases (the maximum diameter of mass is over 10cm, portal vein thrombosis or arteriovenous shunt) in spite of high grade. We believe that these angiographic findings (tumor staining, enlargement of feeding artery, neo vascularity) are one of important indices for anticipating the effect of TAE in patients with unresectable hepatocellular carcinoma

  3. MR imaging assessment of cerebral vascular disease: A combination of angiographic and parenchymal techniques

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Modic, M.T.; Ross, J.S.; Ruggieri, P.; Laub, G.; Haacke, E.M.

    1988-01-01

    This study tested the accuracy and clinical utility of a three-dimensional MR angiographic technique of the cervical carotids in combination with a routine spin-echo examination of the brain as a screening examination for cerebrovascular disease in 23 patients. The technique used a fast low-angle shot sequence with a reduced echo time and voxel size, gradient refocusing, and time of flight effects to minimize signal loss secondary to phase dispersion and maximize vessel contrast. Subsequent multiplanar three-dimensional reconstructions were obtained at 5 0 increments about the z-axis via ray-tracing linear thresholding algorithms. Examinations were compared with IV/IA-digital subtraction angiography or Doppler US as the objective of accuracy. Results of this ongoing study indicate that an MR angiographic screening examination can be coupled with routine brain MR imaging with only a 10-14 minute extension of examination time, providing both a vascular and a parenchymal evaluation

  4. Sub-clinical assessment of atopic dermatitis severity using angiographic optical coherence tomography

    Science.gov (United States)

    Byers, Robert A.; Maiti, Raman; Danby, Simon G.; Pang, Elaine J.; Mitchell, Bethany; Carré, Matt J.; Lewis, Roger; Cork, Michael J.; Matcher, Stephen J.

    2018-01-01

    Measurement of sub-clinical atopic dermatitis (AD) is important for determining how long therapies should be continued after clinical clearance of visible AD lesions. An important biomarker of sub-clinical AD is epidermal hypertrophy, the structural measures of which often make optical coherence tomography (OCT) challenging due to the lack of a clearly delineated dermal-epidermal junction in AD patients. Alternatively, angiographic OCT measurements of vascular depth and morphology may represent a robust biomarker for quantifying the severity of clinical and sub-clinical AD. To investigate this, angiographic data sets were acquired from 32 patients with a range of AD severities. Deeper vascular layers within skin were found to correlate with increasing clinical severity. Furthermore, for AD patients exhibiting no clinical symptoms, the superficial plexus depth was found to be significantly deeper than healthy patients at both the elbow (p = 0.04) and knee (p<0.001), suggesting that sub-clinical changes in severity can be detected. Furthermore, the morphology of vessels appeared altered in patients with severe AD, with significantly different vessel diameter, length, density and fractal dimension. These metrics provide valuable insight into the sub-clinical severity of the condition, allowing the effects of treatments to be monitored past the point of clinical remission. PMID:29675335

  5. CT, MR and angiographic findings of hemangiopericytomas

    International Nuclear Information System (INIS)

    Lim, Soo Mee; Lee, Ho Kyu; Shin, Ji Hoon; Kim, Jae Kyun; Kim, Dae Hong; Choi, Choong Gon; Suh, Dae Chul

    1999-01-01

    Hemangiopericytoma(HP) exhibits its pathologic findings different from those of meningioma or other angiomatous tumor; and its clinical behavior is unique and prognosis worse than other cases. We reviewed the CT, MR and angiographic findings of HPs and evaluated differential radiologic points of comparison between typical meningiomas and meningeal HPs. MR(n=16), CT(n=5) and angiographic imaging(n=10) were performed in 18 patients(M:F = 12:6, mean age: 45 years) with histologically proven primary HPs. We evaluated the imaging findings of HPs with respect to site, shape, size, signal intensity, enhancement characteristics, vascular signal voids, calcification, bony and adjacent sinus involvement, and angiographic findings. HPs were meningeal in 14 cases and nonmeningeal in four. Meningeal HPs were located in the parasagittal region(n=8), convexity(n=3), intradural extramedullary space(n=1), choroid plexus(n=1), and olfactory groove(n=1). Nonmeningeal HPs were located in the masticator space(n=2), paraspinal area(n=1) and supraclavicular area(n=1). The mean maximal dimension of tumors was about 5.4cm and their shape was papillary(n=8) or lobulated(n=7). MR images showed high(n=13) or iso(n=3) signal intensities on T2W1, and heterogeneity on T2W1(n=9). Vascular signal voids in the mass were seen in all cases, while in two cases, CT scanning showed nodular dense calcification. Bone destruction was present in six cases, but no hyperostosis was found. In five cases, the superior sagittal sinus was involved. Angiographic images revealed highly vascular masses supplied by the internal carotid artery(n=5), external carotid artery(n=8), descending scapular artery(n=1) and radiculomedullary artery(n=1), with delayed tumor blush during the capillary and venous phase in which there was no arteriovenous shunt. HP is one of the extra-axial tumors in which there is hypervascularity, aggressive bony destruction arising in the meningeal and extrameningeal area, and heterogeneous high

  6. Influence of the curve density relative electron in dosimetry clinic in treatments stereo tactics

    International Nuclear Information System (INIS)

    Moreno Saiz, C.; Benitez Villegas, E. M.; Casado Villalon, F. J.; Parra Osorio, V.; Bodineau Gil, C.; Garcia Pareja, S.

    2013-01-01

    The objective of this study is to analyze the difference between clinical dosimetry in the treatments with radiosurgery and stereotactic radiotherapy fractional obtained from the relative Electron density curve (Schneider 1996) tabulated and provided with the scanner's radiation therapy. (Author)

  7. MR angiographic and parenchymal evaluation of cerebral infaraction in sickle cell anemia

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Masaryk, A.M.; Ross, J.S.; Modic, M.T.; Wiznitzer, M.; Berman, B.

    1989-01-01

    Cerebral infarction is an important complication of sickle cell anemia, believed to be related to large-vessel stenoses/occlusion and/or capillary/venous sickling resulting in thrombosis. Identification of these complications (especially large-vessel arterial disease) is important in selecting patients for transfusion therapy. The purpose of this study was to determine the suitability of combined three-dimensional Fourier transform time-of-flight MR angiographic and parenchymal T2-weighted spin-echo examinations for evaluation of central nervous system (CNS) complications of sickle cell anemia. Seven patients (age range, 5-14 years) were evaluated. Five had documented strokes while two had symptoms resembling those of transient ischemic attack. The preliminary data indicate that combined MR angiographic and parenchymal studies are capable of identifying those patients with sickle cell anemia complicated by large-vessel CNS occlusive disease and cerebral infarction and can be used as a noninvasive guide to therapy

  8. Spontaneous regression of cerebral arteriovenous malformations: clinical and angiographic analysis with review of the literature

    International Nuclear Information System (INIS)

    Lee, S.K.; Vilela, P.; Willinsky, R.; TerBrugge, K.G.

    2002-01-01

    Spontaneous regression of cerebral arteriovenous malformation (AVM) is rare and poorly understood. We reviewed the clinical and angiographic findings in patients who had spontaneous regression of cerebral AVMs to determine whether common features were present. The clinical and angiographic findings of four cases from our series and 29 cases from the literature were retrospectively reviewed. The clinical and angiographic features analyzed were: age at diagnosis, initial presentation, venous drainage pattern, number of draining veins, location of the AVM, number of arterial feeders, clinical events during the interval period to thrombosis, and interval period to spontaneous thrombosis. Common clinical and angiographic features of spontaneous regression of cerebral AVMs are: intracranial hemorrhage as an initial presentation, small AVMs, and a single draining vein. Spontaneous regression of cerebral AVMs can not be predicted by clinical or angiographic features, therefore it should not be considered as an option in cerebral AVM management, despite its proven occurrence. (orig.)

  9. Feasibility and Safety of Transradial Arterial Approach for Simultaneous Right and Left Vertebral Artery Angiographic Studies and Stenting

    International Nuclear Information System (INIS)

    Yip, H.-K.; Youssef, Ali A.; Chang, W.-N.; Lu, C.-H.; Yang, C.-H.; Chen, S.-M.; Wu, C.-J.

    2007-01-01

    Objectives. This study investigated whether the transradial artery (TRA) approach using a 6-French (F) Kimny guiding catheter for right vertebral artery (VA) angiographic study and stenting is safe and effective for patients with significant VA stenosis. Background. The TRA approach is commonly performed worldwide for both diagnostic cardiac catheterization and catheter-based coronary intervention. However, to our knowledge, the safety and feasibility of left and right VA angiographic study and stenting, in the same procedure, using the TRA approach for patients with brain ischemia have not been reported. Methods. The study included 24 consecutive patients (22 male, 2 female; age, 63-78 years). Indications for VA angiographic study and stenting were (1) prior stroke or symptoms related to vertebrobasilar ischemia and (2) an asymptomatic but vertebral angiographic finding of severe stenosis (>70%). A combination of the ipsilateral and retrograde-engagement technique, which involved a looping 6-F Kimny guiding catheter, was utilized for VA angiographic study. For VA stenting, an ipsilateral TRA approach with either a Kimny guiding catheter or a left internal mammary artery guiding catheter was utilized in 22 patients and retrograde-engagement technique in 2 patients. Results. A technically successful procedure was achieved in all patients, including left VA stenting in 15 patients and right VA stenting in 9 patients. The mean time for stenting (from engagement to stent deployment) was 12.7 min. There were no vascular complications or mortality. However, one patient suffered from a transient ischemic attack that resolved within 3 h. Conclusion. We conclude that TRA access for both VA angiographic study and VA stenting is safe and effective, and provides a simple and useful clinical tool for patients unsuited for femoral arterial access

  10. Bezier-curve Navigation Guidance for Impact Time and Angle Control

    Directory of Open Access Journals (Sweden)

    Gun-Hee MOON

    2018-03-01

    Full Text Available This paper addresses a novel impact time and angle control guidance law using a Bézier curve. The 2nd order Bézier curve consists of one control point and two boundary points; initial point P0, middle point P1 and end point P2. The curve is tangent to the line P0-P1 and the line P1-P2, respectively, and always exists in the convex hull of the control points. Proposed Bézier curve navigation guidance, makes the missile follow the Bézier curve with the feedback form of guidance command so that the missile hits the target on the desired time in the desired direction. We conducted numerical simulations on several terminal conditions to demonstrate the performance of proposed method.

  11. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    International Nuclear Information System (INIS)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi

    1991-01-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner [PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01]. Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR [T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01]. However, T-PER/RR and T-PFR/RR values were rather constant (20.9±3.2%, 17.0±2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high [r= 0.91 p<0.001]. To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author)

  12. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    Energy Technology Data Exchange (ETDEWEB)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi (Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine)

    1991-05-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner (PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01). Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR (T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01). However, T-PER/RR and T-PFR/RR values were rather constant (20.9+-3.2%, 17.0+-2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high (r= 0.91 p<0.001). To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author).

  13. Adult Moyamoya disease angiographic images evolutive characters and treatment methods

    International Nuclear Information System (INIS)

    Qian Jiangnan; Ling Feng

    2000-01-01

    Objective: To discuss the angiographic images with evolutional characters and the treatment methods of the Moyamoya disease. Methods: The clinical manifestations, the radiographic changes and the comparative analysis between medicine treatment and surgery treatment, together with the laboratory tests findings were analyzed in one cases adult Moyamoya disease during six years. Conclusions: The angiographic characteristics of MMD show the supplied artery trunk stenosis, and followed by occlusion, with later appearance of vascular smoking sign. Medical treatment proved to be of null. Direct or indirect intra or extra cranial vascular anastomosis are effective for treatment

  14. Simulation of density curve for slim borehole using the Monte Carlo code MCNPX

    International Nuclear Information System (INIS)

    Souza, Edmilson Monteiro de; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu; Lima, Inaya C.B.; Rocha, Paula L.F.

    2010-01-01

    Borehole logging for formation density has been an important geophysical measurement in oil industry. For calibration of the Gamma Ray nuclear logging tool, numerous rock models of different lithology and densities are necessary. However, the full success of this calibration process is determined by a reliable benchmark, where the complete and precise chemical composition of the standards is necessary. Simulations using the Monte Carlo MCNP have been widely employed in well logging application once it serves as a low-cost substitute for experimental test pits, as well as a means for obtaining data that are difficult to obtain experimentally. Considering this, the purpose of this work is to use the code MCNP to obtain density curves for slim boreholes using Gamma Ray logging tools. For this, a Slim Density Gamma Probe, named TRISOND R , and a 100 mCi Cs-137 gamma source has been modeled with the new version of MCNP code MCNPX. (author)

  15. Simulation of density curve for slim borehole using the Monte Carlo code MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Edmilson Monteiro de; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu, E-mail: emonteiro@nuclear.ufrj.b, E-mail: ademir@nuclear.ufrj.b, E-mail: ricardo@lin.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Correa, Samanda Cristine Arruda, E-mail: scorrea@nuclear.ufrj.b [Centro Universitario Estadual da Zona Oeste (CCMAT/UEZO), Rio de Janeiro, RJ (Brazil); Lima, Inaya C.B., E-mail: inaya@lin.ufrj.b [Universidade Estadual do Rio de Janeiro (IPRJ/UERJ) Nova Friburgo, Rio de Janeiro, RJ (Brazil). Instituto Politecnico do Rio de Janeiro; Rocha, Paula L.F., E-mail: ferrucio@acd.ufrj.b [Universidade Federal do Rio de Janeiro (UFRJ) RJ (Brazil). Dept. de Geologia

    2010-07-01

    Borehole logging for formation density has been an important geophysical measurement in oil industry. For calibration of the Gamma Ray nuclear logging tool, numerous rock models of different lithology and densities are necessary. However, the full success of this calibration process is determined by a reliable benchmark, where the complete and precise chemical composition of the standards is necessary. Simulations using the Monte Carlo MCNP have been widely employed in well logging application once it serves as a low-cost substitute for experimental test pits, as well as a means for obtaining data that are difficult to obtain experimentally. Considering this, the purpose of this work is to use the code MCNP to obtain density curves for slim boreholes using Gamma Ray logging tools. For this, a Slim Density Gamma Probe, named TRISOND{sup R}, and a 100 mCi Cs-137 gamma source has been modeled with the new version of MCNP code MCNPX. (author)

  16. LATE-TIME LIGHT CURVES OF TYPE II SUPERNOVAE: PHYSICAL PROPERTIES OF SUPERNOVAE AND THEIR ENVIRONMENT

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Masaaki; Meixner, Margaret; Panagia, Nino [Space Telescope Science Institute, 3700 San Martin Dr., Baltimore, MD 21218 (United States); Fabbri, Joanna; Barlow, Michael J.; Wesson, Roger [Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT (United Kingdom); Clayton, Geoffrey C.; Andrews, Jennifer E. [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Gallagher, Joseph S. [Department of Mathematics, Physics, and Computer Science, Raymond Walters College, 9555 Plain field Rd., Blue Ash, OH 45236 (United States); Sugerman, Ben E. K. [Department of Physics and Astronomy, Goucher College, 1021 Dulaney Valley Road, Baltimore, MD 21204 (United States); Ercolano, Barbara [Universitaets-Sternwarte Muenchen, Scheinerstr. 1, 81679 Muenchen (Germany); Welch, Douglas, E-mail: otsuka@stsci.edu, E-mail: otsuka@asiaa.sinica.edu.tw [Department of Physics and Astronomy, McMaster University, Hamilton, Ontario L8S 4M1 (Canada)

    2012-01-01

    We present BVRIJHK-band photometry of six core-collapse supernovae, SNe 1999bw, 2002hh, 2003gd, 2004et, 2005cs, and 2006bc, measured at late epochs (>2 yr) based on the Hubble Space Telescope (HST), and the Gemini North, and WIYN telescopes. We also show the JHK light curves of supernova impostor SN 2008S up to day 575 because it was serendipitously in our SN 2002hh field of view. Of our 43 HST observations in total, 36 observations are successful in detecting the light from the SNe alone and measuring magnitudes of all the targets. HST observations show a resolved scattered light echo around SN 2003gd at day 1520 and around SN 2002hh at day 1717. Our Gemini and WIYN observations detected SNe 2002hh and 2004et as well. Combining our data with previously published data, we show VRIJHK-band light curves and estimate decline magnitude rates at each band in four different phases. Our prior work on these light curves and other data indicate that dust is forming in our targets from days {approx}300 to 400, supporting SN dust formation theory. In this paper we focus on other physical properties derived from late-time light curves. We estimate {sup 56}Ni masses for our targets (0.5-14 Multiplication-Sign 10{sup -2} M{sub Sun }) from the bolometric light curve of each of days {approx}150-300 using SN 1987A as a standard (7.5 Multiplication-Sign 10{sup -2} M{sub Sun }). The flattening or sometimes increasing fluxes in the late-time light curves of SNe 2002hh, 2003gd, 2004et, and 2006bc indicate the presence of light echoes. We estimate the circumstellar hydrogen density of the material causing the light echo and find that SN 2002hh is surrounded by relatively dense materials (n(H) >400 cm{sup -3}) and SNe 2003gd and 2004et have densities more typical of the interstellar medium ({approx}1 cm{sup -3}). We analyze the sample as a whole in the context of physical properties derived in prior work. The {sup 56}Ni mass appears well correlated with progenitor mass with a slope of 0

  17. Real-Time Exponential Curve Fits Using Discrete Calculus

    Science.gov (United States)

    Rowe, Geoffrey

    2010-01-01

    An improved solution for curve fitting data to an exponential equation (y = Ae(exp Bt) + C) has been developed. This improvement is in four areas -- speed, stability, determinant processing time, and the removal of limits. The solution presented avoids iterative techniques and their stability errors by using three mathematical ideas: discrete calculus, a special relationship (be tween exponential curves and the Mean Value Theorem for Derivatives), and a simple linear curve fit algorithm. This method can also be applied to fitting data to the general power law equation y = Ax(exp B) + C and the general geometric growth equation y = Ak(exp Bt) + C.

  18. Essentials of diagnostic and interventional angiographic technique

    International Nuclear Information System (INIS)

    Gerlock, A.J.; Mirfakhraee, M.

    1985-01-01

    This volume presents coverage of basic angiographic techniques and shows how to get to the point of taking the angiogram, and tells how to avoid pitfalls. Particularly valuable is the information on how to get out of trouble if an error is made while manipulating the catheter

  19. Development of DIGITEXαPlus digital angiographic system

    International Nuclear Information System (INIS)

    Imanishi, Tetsuo; Miura, Yusuke; Sasaki, Osamu; Furuyama, Makoto; Yasumi, Masayuki

    2001-01-01

    The functions required of digital angiographic (DA) systems have been noticeably changing with the recent popularization of the technique of interventional radiology (IVR) in the field of angiography. We have developed a new digital angiographic system, named the DIGITEXαPlus, which is designed to meet the requirements of the latest IVR technologies. The DIGITEXαPlus system is equipped with a high-performance one-million-pixel CCD camera, a newly developed F.P.O. (fluoro-power optimizer), and a contrast-priority radiography control system, which combine together to provide high quality of images both in fluoroscopy and in fluorography. In this new system, a low-dose pulsed fluoroscopy method, employed as standard, minimizes the X-ray doses to patients, and an image controller (IVR MASTER) of a joy stick type provides more diversified functions that its predecessors. These two features enhance the reliability, and simplifies the operation, of the IVR system as a whole. (author)

  20. High-resolution time series of Pseudomonas aeruginosa gene expression and rhamnolipid secretion through growth curve synchronization

    Directory of Open Access Journals (Sweden)

    Xavier João B

    2011-06-01

    Full Text Available Abstract Background Online spectrophotometric measurements allow monitoring dynamic biological processes with high-time resolution. Contrastingly, numerous other methods require laborious treatment of samples and can only be carried out offline. Integrating both types of measurement would allow analyzing biological processes more comprehensively. A typical example of this problem is acquiring quantitative data on rhamnolipid secretion by the opportunistic pathogen Pseudomonas aeruginosa. P. aeruginosa cell growth can be measured by optical density (OD600 and gene expression can be measured using reporter fusions with a fluorescent protein, allowing high time resolution monitoring. However, measuring the secreted rhamnolipid biosurfactants requires laborious sample processing, which makes this an offline measurement. Results Here, we propose a method to integrate growth curve data with endpoint measurements of secreted metabolites that is inspired by a model of exponential cell growth. If serial diluting an inoculum gives reproducible time series shifted in time, then time series of endpoint measurements can be reconstructed using calculated time shifts between dilutions. We illustrate the method using measured rhamnolipid secretion by P. aeruginosa as endpoint measurements and we integrate these measurements with high-resolution growth curves measured by OD600 and expression of rhamnolipid synthesis genes monitored using a reporter fusion. Two-fold serial dilution allowed integrating rhamnolipid measurements at a ~0.4 h-1 frequency with high-time resolved data measured at a 6 h-1 frequency. We show how this simple method can be used in combination with mutants lacking specific genes in the rhamnolipid synthesis or quorum sensing regulation to acquire rich dynamic data on P. aeruginosa virulence regulation. Additionally, the linear relation between the ratio of inocula and the time-shift between curves produces high-precision measurements of

  1. Long-term Luminal Renarrowing After Successful Elective Coronary Angioplasty of Total Occlusions : A Quantitative Angiographic Analysis

    NARCIS (Netherlands)

    A.G. Violaris (Andonis); R. Melkert (Rein); P.W.J.C. Serruys (Patrick)

    1995-01-01

    textabstractBackground The long-term angiographic outcome after successful dilatation of coronary occlusions remains unclear. The objective of this study was to examine long-term restenosis after successful balloon dilatation of coronary occlusions at a predetermined time interval with quantitative

  2. Angiographic study of digital arteries in workers exposed to vinyl chloride

    Energy Technology Data Exchange (ETDEWEB)

    Falappa, P; Magnavita, N; Bergamaschi, A; Colavita, N

    1982-05-01

    Five patients exposed to vinyl chloride were studied by hand angiography and other non-invasive methods, including photoplethysmography, rheography, and thermography. Raynaud's phenomenon was present in all five subjects, while acro-osteolysis affected only one. Organic vascular lesions, such as narrowing, segmentary occlusions of digital arteries and bridge collaterals, were found in angiographic studies. Only one patient did not show clear segmentary occlusions, but his vessels were crooked and diffusely narrowed. Angiographic results appear to correlate well with the changes shown by non-invasive techniques.

  3. Quantum field theory in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Davies, P C.W. [King' s Coll., London (UK)

    1976-09-30

    It is stated that recent theoretical developments indicate that the presence of gravity (curved space-time) can give rise to important new quantum effects, such as cosmological particle production and black-hole evaporation. These processes suggest intriguing new relations between quantum theory, thermodynamics and space-time structure and encourage the hope that a better understanding of a full quantum theory of gravity may emerge from this approach.

  4. The predictive value of angiographic results for the outcome of percutaneous transluminal angioplasty in stenosed femoral bypass grafts

    International Nuclear Information System (INIS)

    Spijkerboer, Anje M.; Beek, Frederik J. A.; Graaf, Yolanda van der; Eikelboom, Bert C.; Mali, Willem P. T. M.

    1997-01-01

    Purpose. To assess the predictive value of immediate angiographic results after percutaneous transluminal angioplasty (PTA) for stenoses in femoral bypass grafts using duplex ultrasound (DUS) criteria. Methods. A 1-year follow-up with DUS was performed in 38 patients with 50 stenoses in 41 grafts, treated with PTA for a graft stenosis. The indication for PTA according to DUS criteria was a severe stenosis in 43 lesions, and a moderate stenosis in 7 lesions. In the moderate stenosis group 3 patients showed claudication and 1 patient had a nonhealing ulcer. For the purposes of statistical evaluation, primary patency was considered present if the graft was not occluded. The graft was considered to have failed when it was found to be occluded on DUS, or when secondary interventions (surgery, repeat PTA) were performed. Results. After 1 year the cumulative primary patency rate was 44$ [95% confidence interval (CI) 27.8-59.8]. Stenoses with initially good angiographic results after PTA (<30% residual stenosis) were 2.9 times more likely to be patent at 1 year than stenoses with initially poor or moderate angiographic results (hazard ratio 2.9, 95% CI 1.3-6.4,p=0.007). Conclusion. A poor or moderate angiographic result immediately following PTA was prognostic for poor long-term results and may indicate a requirement for earlier surgical intervention

  5. Shock Index Correlates with Extravasation on Angiographs of Gastrointestinal Hemorrhage: A Logistics Regression Analysis

    International Nuclear Information System (INIS)

    Nakasone, Yutaka; Ikeda, Osamu; Yamashita, Yasuyuki; Kudoh, Kouichi; Shigematsu, Yoshinori; Harada, Kazunori

    2007-01-01

    We applied multivariate analysis to the clinical findings in patients with acute gastrointestinal (GI) hemorrhage and compared the relationship between these findings and angiographic evidence of extravasation. Our study population consisted of 46 patients with acute GI bleeding. They were divided into two groups. In group 1 we retrospectively analyzed 41 angiograms obtained in 29 patients (age range, 25-91 years; average, 71 years). Their clinical findings including the shock index (SI), diastolic blood pressure, hemoglobin, platelet counts, and age, which were quantitatively analyzed. In group 2, consisting of 17 patients (age range, 21-78 years; average, 60 years), we prospectively applied statistical analysis by a logistics regression model to their clinical findings and then assessed 21 angiograms obtained in these patients to determine whether our model was useful for predicting the presence of angiographic evidence of extravasation. On 18 of 41 (43.9%) angiograms in group 1 there was evidence of extravasation; in 3 patients it was demonstrated only by selective angiography. Factors significantly associated with angiographic visualization of extravasation were the SI and patient age. For differentiation between cases with and cases without angiographic evidence of extravasation, the maximum cutoff point was between 0.51 and 0.0.53. Of the 21 angiograms obtained in group 2, 13 (61.9%) showed evidence of extravasation; in 1 patient it was demonstrated only on selective angiograms. We found that in 90% of the cases, the prospective application of our model correctly predicted the angiographically confirmed presence or absence of extravasation. We conclude that in patients with GI hemorrhage, angiographic visualization of extravasation is associated with the pre-embolization SI. Patients with a high SI value should undergo study to facilitate optimal treatment planning

  6. Effect of higher implant density on curve correction in dystrophic thoracic scoliosis secondary to neurofibromatosis Type 1.

    Science.gov (United States)

    Li, Yang; Yuan, Xinxin; Sha, Shifu; Liu, Zhen; Zhu, Weiguo; Qiu, Yong; Wang, Bin; Yu, Yang; Zhu, Zezhang

    2017-10-01

    OBJECTIVE The aim of this study was to investigate how implant density affects radiographic results and clinical outcomes in patients with dystrophic scoliosis secondary to neurofibromatosis Type 1 (NF1). METHODS A total of 41 patients with dystrophic scoliosis secondary to NF1 who underwent 1-stage posterior correction between June 2011 and December 2013 were included. General information about patients was recorded, as were preoperative and postoperative scores from Scoliosis Research Society (SRS)-22 questionnaires. Pearson correlation analysis was used to analyze the associations among implant density, coronal Cobb angle correction rate and correction loss at last follow-up, change of sagittal curve, and apical vertebral translation. Patients were then divided into 2 groups: those with low-density and those with high-density implants. Independent-sample t-tests were used to compare demographic data, radiographic findings, and clinical outcomes before surgery and at last follow-up between the groups. RESULTS Significant correlations were found between the implant density and the coronal correction rate of the main curve (r = 0.505, p density and change of sagittal profile (p = 0.662) or apical vertebral translation (p = 0.062). The SRS-22 scores improved in the appearance, activity, and mental health domains within both groups, but there was no difference between the groups in any of the SRS-22 domains at final follow-up (p > 0.05 for all). CONCLUSIONS Although no significant differences between the high- and low-density groups were found in any of the SRS-22 domains at final follow-up, higher implant density was correlated with superior coronal correction and less postoperative correction loss in patients with dystrophic NF1-associated scoliosis.

  7. MICA: Multiple interval-based curve alignment

    Science.gov (United States)

    Mann, Martin; Kahle, Hans-Peter; Beck, Matthias; Bender, Bela Johannes; Spiecker, Heinrich; Backofen, Rolf

    2018-01-01

    MICA enables the automatic synchronization of discrete data curves. To this end, characteristic points of the curves' shapes are identified. These landmarks are used within a heuristic curve registration approach to align profile pairs by mapping similar characteristics onto each other. In combination with a progressive alignment scheme, this enables the computation of multiple curve alignments. Multiple curve alignments are needed to derive meaningful representative consensus data of measured time or data series. MICA was already successfully applied to generate representative profiles of tree growth data based on intra-annual wood density profiles or cell formation data. The MICA package provides a command-line and graphical user interface. The R interface enables the direct embedding of multiple curve alignment computation into larger analyses pipelines. Source code, binaries and documentation are freely available at https://github.com/BackofenLab/MICA

  8. Multivariate analysis of diagnostic parameters derived from whole-kidney and parenchymal time-activity curves

    International Nuclear Information System (INIS)

    Bergmann, H.; Mostbeck, A.; Samal, M.; Nimmon, C.C.; Staudenherz, A.; Dudczak, R.

    2002-01-01

    Aim: In a previous work, we have confirmed earlier reports that time-activity curves of renal cortex provide additional useful diagnostic information. The aim of this experiment was to support the finding quantitatively using multiple regression. Materials and Methods: In a retrospective study, we have analyzed MAG3 renal data (90 kidneys in 57 children). Whole-kidney (WK) and parenchymal (PA) time-activity curves were extracted from 20 min pre-diuretic phase using standard WK and parenchymal fuzzy ROIs. Using multiple regression analysis, peak time, mean transit time, output efficiency, and four additional indices of residual activity in WK and PA ROIs were related to the maximum elimination rate (EM) of urine after the diuretic. The kidneys were divided into four groups according to the WK peak time (WKPT): WKPT longer than 0 (all kidneys), 5, 10, and 15 min. Results: Multiple correlation coefficients between the set of WK, PA, and WK+PA curve parameters (independent variables) and the log EM (dependent variable) for each group are summarized. Conclusions: Using pre-diuretic time-activity curves, it is possible to predict diuretic response. This can be useful when interpreting dubious results. Parenchymal curves predict diuretic response better than the whole-kidney curves. With increasing WKPT the whole-kidney curves become useless, while the parenchymal curves are still useful. Using both WK and PA curves produces the best results. This demonstrates that both WK and PA curves carry independent diagnostic information. The contribution obtained from the parenchymal curves certainly worth the difficulties and time required to draw additional ROIs. However, substantial efforts have to be given to the accurate and reproducible definition of parenchymal ROIs

  9. Thermodynamics in Curved Space-Time and Its Application to Holography

    Directory of Open Access Journals (Sweden)

    Yong Xiao

    2015-03-01

    Full Text Available The thermodynamic behaviors of a system living in a curved space-time are different from those of a system in a flat space-time. We have investigated the thermodynamics for a system consisting of relativistic massless bosons. We show that a strongly curved metric will produce a large enhancement of the degrees of freedom in the formulae of energy and entropy of the system, as a comparison to the case in a flat space-time. We are mainly concerned with its implications to holography, including the derivations of holographic entropy and holographic screen.

  10. Serum high sensitivity C-reactive protein levels and the severity of coronary atherosclerosis assessed by angiographic gensini score

    International Nuclear Information System (INIS)

    Masood, A.; Jafar, S.S.; Akram, Z.

    2011-01-01

    Objective: To assess the relationship between plasma high sensitivity C-reactive protein levels with severity of coronary atherosclerosis. Materials and Methods: The study included 80 patients subjected to coronary angiography. The extent of Coronary Artery Disease (CAD) was assessed using Gensini score. Patients were divided into three risk groups according to hs-CRP levels ( 3mg/L- as high risk). Mean Angiographic Gensini scores were compared among the risk groups. Correlation between serum hs-CRP levels and angiographic Gensini scores was also assessed. Results: The 26 (32.5%) patients belonging to hs-CRP low-risk group had a mean angiographic Gensini score of 11.8 +- 5.8, 18 (22.5%) belonging to moderate-risk group had a mean score of 28.9 +- 7.9 and 36 (45%) belonging to high- risk group had a mean score of 78.7 +- 41.0. By applying ANOVA the mean angiographic Gensini scores showed increasing trend from lower to higher hs-CRP risk groups (p < 0.001). Serum hs-CRP levels showed significant correlation with respective angiographic Gensini scores by Pearson's correlation (p < 0.001). Conclusion: Serum hs-CRP levels show significant correlation with the severity of Coronary Artery Disease as assessed by angiographic Gensini score. (author)

  11. Hepatic angiographic findings of ruptured hepatocellular carcinoma: 'Sentinel signs' versus extravasation

    International Nuclear Information System (INIS)

    Yun, Seong Jong; Nam, Deok Ho

    2014-01-01

    This study retrospectively compared the accuracy of angiographic sentinel signs (sentinel vessels, hypovascular areas, and delayed dots) with extravasation in the diagnosis of ruptured hepatocellular carcinoma (HCC). Sixteen patients diagnosed with HCC between March 2007 and November 2011 were evaluated. Among the patients, we identified 32 HCCs (19 ruptured, 13 unruptured), and assessed all HCCs by hepatic angiography with regard to extravasation, sentinel vessels, hypovascular areas, and delayed dots. We compared the sensitivity and specificity of the sentinel signs with those of the extravasation for the diagnosis of a ruptured HCC. For the angiographic diagnosis of a ruptured HCC, the sensitivity of the sentinel signs (sentinel vessel, 63.2%; hypovascular area, 89.5%; delayed dot, 72.7%) was higher than the sensitivity of extravasation (15.8%). The difference in sensitivity between each sentinel sign and extravasation was statistically significant (sentinel vessel, p = 0.012; hypovascular area, p < 0.001; delayed dot, p 0.039). The specificity of sentinel signs for the diagnosis of ruptured HCC was not statistically different from the specificity of extravasation. Sentinel signs are more accurate than extravasation for the angiographic diagnosis of a ruptured HCC.

  12. Transarterial embolization in the management of intractable epistaxis: the angiographic findings and results based on etiologies.

    Science.gov (United States)

    Wang, Bin; Zu, Qing-Quan; Liu, Xing-Long; Zhou, Chun-Gao; Xia, Jin-Guo; Zhao, Lin-Bo; Shi, Hai-Bin; Liu, Sheng

    2016-08-01

    Transarterial embolization (TAE) appears to be a safe and effective treatment for patients with intractable epistaxis, despite different etiologies or angiography findings. Idiopathic epistaxis is prone to present with negative angiographic findings. To retrospectively evaluate the safety and effectiveness of TAE for intractable epistaxis, and focus on the factors of etiology and angiographic findings. From March 2008 to December 2014, the data of 43 patients with intractable bleeding undergoing TAE were reviewed. The outcomes of interventional therapy were assessed according to different etiology (malignant or benign disease) and angiographic finding (positive or negative angiogram). Positive angiographic findings were found in 11 of 12 cases with malignant diseases and 22 of 31 cases with benign diseases, respectively (p = 0.237). Among the 10 cases with negative angiographic findings, the negative angiography rate of idiopathic epistaxis was higher than that of epistaxis with definite etiology (p = 0.003). Bleeding was controlled successfully in all of the 43 patients after embolization. During the mean follow-up period of 24.0 ± 16.7 months, five patients relapsed. No significant difference was found in recurrence rates between malignant and benign diseases or between positive and negative angiography (p = 0.241, p = 0.704, respectively).

  13. Estimation of Curve Tracing Time in Supercapacitor based PV Characterization

    Science.gov (United States)

    Basu Pal, Sudipta; Das Bhattacharya, Konika; Mukherjee, Dipankar; Paul, Debkalyan

    2017-08-01

    Smooth and noise-free characterisation of photovoltaic (PV) generators have been revisited with renewed interest in view of large size PV arrays making inroads into the urban sector of major developing countries. Such practice has recently been observed to be confronted by the use of a suitable data acquisition system and also the lack of a supporting theoretical analysis to justify the accuracy of curve tracing. However, the use of a selected bank of supercapacitors can mitigate the said problems to a large extent. Assuming a piecewise linear analysis of the V-I characteristics of a PV generator, an accurate analysis of curve plotting time has been possible. The analysis has been extended to consider the effect of equivalent series resistance of the supercapacitor leading to increased accuracy (90-95%) of curve plotting times.

  14. Cerebral angiographic changes on serial examination of a patient with migraine

    Energy Technology Data Exchange (ETDEWEB)

    Masuzawa, T.; Shinoda, S.; Nakahara, N.; Abe, F.; Sato, F.; Furuse, M.

    1983-03-01

    Curious cerebral angiographic changes are described in a 27-year-old female migraine patient. During the period of observation of this patient, both the intracranial carotid artery and the vertebrobasilar artery systems presented unusual and fascinating cerebral arteriographic pictures. In an attack of migraine, angiography showed that all the intracranial secondary and tertiary branches of the carotid arterial system were dilated without showing any changes in the extracranial arteries and when the migraine attack had subsided, all branches of the carotid arteries as well as the vertebrobasilar arteries demonstreated abnormal segmental narrowings or vasospasm. These sequential angiographic changes have not been hitherto reported in migraine.

  15. Renal artery origins: best angiographic projection angles.

    Science.gov (United States)

    Verschuyl, E J; Kaatee, R; Beek, F J; Patel, N H; Fontaine, A B; Daly, C P; Coldwell, D M; Bush, W H; Mali, W P

    1997-10-01

    To determine the best projection angles for imaging the renal artery origins in profile. A mathematical model of the anatomy at the renal artery origins in the transverse plane was used to analyze the amount of aortic lumen that projects over the renal artery origins at various projection angles. Computed tomographic (CT) angiographic data about the location of 400 renal artery origins in 200 patients were statistically analyzed. In patients with an abdominal aortic diameter no larger than 3.0 cm, approximately 0.5 mm of the proximal part of the renal artery and origin may be hidden from view if there is a projection error of +/-10 degrees from the ideal image. A combination of anteroposterior and 20 degrees and 40 degrees left anterior oblique projections resulted in a 92% yield of images that adequately profiled the renal artery origins. Right anterior oblique projections resulted in the least useful images. An error in projection angle of +/-10 degrees is acceptable for angiographic imaging of the renal artery origins. Patients sex, site of interest (left or right artery), and local diameter of the abdominal aorta are important factors to consider.

  16. An analytic regularisation scheme on curved space–times with applications to cosmological space–times

    International Nuclear Information System (INIS)

    Géré, Antoine; Hack, Thomas-Paul; Pinamonti, Nicola

    2016-01-01

    We develop a renormalisation scheme for time-ordered products in interacting field theories on curved space–times that consists of an analytic regularisation of Feynman amplitudes and a minimal subtraction of the resulting pole parts. This scheme is directly applicable to space–times with Lorentzian signature, manifestly generally covariant, invariant under any space–time isometries present, and constructed to all orders in perturbation theory. Moreover, the scheme correctly captures the nongeometric state-dependent contribution of Feynman amplitudes, and it is well suited for practical computations. To illustrate this last point, we compute explicit examples on a generic curved space–time and demonstrate how momentum space computations in cosmological space–times can be performed in our scheme. In this work, we discuss only scalar fields in four space–time dimensions, but we argue that the renormalisation scheme can be directly generalised to other space–time dimensions and field theories with higher spin as well as to theories with local gauge invariance. (paper)

  17. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G.

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  18. A new form of the calibration curve in radiochromic dosimetry. Properties and results

    International Nuclear Information System (INIS)

    Tamponi, Matteo; Bona, Rossana; Poggiu, Angela; Marini, Piergiorgio

    2016-01-01

    Purpose: This work describes a new form of the calibration curve for radiochromic dosimetry that depends on one fit parameter. Some results are reported to show that the new curve performs as well as those previously used and, more importantly, significantly reduces the dependence on the lot of films, the film orientation on the scanner, and the time after exposure. Methods: The form of the response curve makes use of the net optical densities ratio against the dose and has been studied by means of the Beer–Lambert law and a simple modeling of the film. The new calibration curve has been applied to EBT3 films exposed at 6 and 15 MV energy beams of linear accelerators and read-out in transmission mode by means of a flatbed color scanner. Its performance has been compared to that of two established forms of the calibration curve, which use the optical density and the net optical density against the dose. Four series of measurements with four lots of EBT3 films were used to evaluate the precision, accuracy, and dependence on the time after exposure, orientation on the scanner and lot of films. Results: The new calibration curve is roughly subject to the same dose uncertainty, about 2% (1 standard deviation), and has the same accuracy, about 1.5% (dose values between 50 and 450 cGy), as the other calibration curves when films of the same lot are used. Moreover, the new calibration curve, albeit obtained from only one lot of film, shows a good agreement with experimental data from all other lots of EBT3 films used, with an accuracy of about 2% and a relative dose precision of 2.4% (1 standard deviation). The agreement also holds for changes of the film orientation and of the time after exposure. Conclusions: The dose accuracy of this new form of the calibration curve is always equal to or better than those obtained from the two types of curves previously used. The use of the net optical densities ratio considerably reduces the dependence on the lot of films, the

  19. A new form of the calibration curve in radiochromic dosimetry. Properties and results

    Energy Technology Data Exchange (ETDEWEB)

    Tamponi, Matteo, E-mail: mtamponi@aslsassari.it; Bona, Rossana; Poggiu, Angela; Marini, Piergiorgio [Medical Physics Unit, ASL Sassari, Via Enrico de Nicola, Sassari 07100 (Italy)

    2016-07-15

    Purpose: This work describes a new form of the calibration curve for radiochromic dosimetry that depends on one fit parameter. Some results are reported to show that the new curve performs as well as those previously used and, more importantly, significantly reduces the dependence on the lot of films, the film orientation on the scanner, and the time after exposure. Methods: The form of the response curve makes use of the net optical densities ratio against the dose and has been studied by means of the Beer–Lambert law and a simple modeling of the film. The new calibration curve has been applied to EBT3 films exposed at 6 and 15 MV energy beams of linear accelerators and read-out in transmission mode by means of a flatbed color scanner. Its performance has been compared to that of two established forms of the calibration curve, which use the optical density and the net optical density against the dose. Four series of measurements with four lots of EBT3 films were used to evaluate the precision, accuracy, and dependence on the time after exposure, orientation on the scanner and lot of films. Results: The new calibration curve is roughly subject to the same dose uncertainty, about 2% (1 standard deviation), and has the same accuracy, about 1.5% (dose values between 50 and 450 cGy), as the other calibration curves when films of the same lot are used. Moreover, the new calibration curve, albeit obtained from only one lot of film, shows a good agreement with experimental data from all other lots of EBT3 films used, with an accuracy of about 2% and a relative dose precision of 2.4% (1 standard deviation). The agreement also holds for changes of the film orientation and of the time after exposure. Conclusions: The dose accuracy of this new form of the calibration curve is always equal to or better than those obtained from the two types of curves previously used. The use of the net optical densities ratio considerably reduces the dependence on the lot of films, the

  20. What have we learned from quantum field theory in curved space-time

    International Nuclear Information System (INIS)

    Fulling, S.A.

    1984-01-01

    The paper reviews the quantum field theory in curved space-time. Field quantization in gravitational backgrounds; particle creation by black holes; Hawking radiation; quantum field theory in curved space-time; covariant renormalization of the stress-energy-momentum tensor; quantum field theory and quantum gravity; are all discussed. (U.K.)

  1. Existence of time-dependent density-functional theory for open electronic systems: time-dependent holographic electron density theorem.

    Science.gov (United States)

    Zheng, Xiao; Yam, ChiYung; Wang, Fan; Chen, GuanHua

    2011-08-28

    We present the time-dependent holographic electron density theorem (TD-HEDT), which lays the foundation of time-dependent density-functional theory (TDDFT) for open electronic systems. For any finite electronic system, the TD-HEDT formally establishes a one-to-one correspondence between the electron density inside any finite subsystem and the time-dependent external potential. As a result, any electronic property of an open system in principle can be determined uniquely by the electron density function inside the open region. Implications of the TD-HEDT on the practicality of TDDFT are also discussed.

  2. Clinical and angiographic predictors of haemodynamically significant angiographic lesions: development and validation of a risk score to predict positive fractional flow reserve.

    Science.gov (United States)

    Sareen, Nishtha; Baber, Usman; Kezbor, Safwan; Sayseng, Sonny; Aquino, Melissa; Mehran, Roxana; Sweeny, Joseph; Barman, Nitin; Kini, Annapoorna; Sharma, Samin K

    2017-04-07

    Coronary revascularisation based upon physiological evaluation of lesions improves clinical outcomes. Angiographic or visual stenosis assessment alone is insufficient in predicting haemodynamic stenosis severity by fractional flow reserve (FFR) and therefore cannot be used to guide revascularisation, particularly in the lesion subset system formulated. Of 1,023 consecutive lesions (883 patients), 314 (31%) were haemodynamically significant. Characteristics associated with FFR ≤0.8 include male gender, higher SYNTAX score, lesions ≥20 mm, stenosis >50%, bifurcation, calcification, absence of tortuosity and smaller reference diameter. A user-friendly integer score was developed with the five variables demonstrating the strongest association. On prospective validation (in 279 distinct lesions), the increasing value of the score correlated well with increasing haemodynamic significance (C-statistic 0.85). We identified several clinical and angiographic characteristics and formulated a scoring system to guide the approach to intermediate lesions. This may translate into cost savings. Larger studies with prospective validation are required to confirm our results.

  3. Intravenous digital subtraction angiography contrast media time-concentration curves

    International Nuclear Information System (INIS)

    Burbank, F.H.; Brody, W.R.

    1985-01-01

    At any specified radiation dose and system signal-to-noise ratio, temporal (masked-mode) intravenous digital subtraction angiography (IV-DSA) image quality is dependent upon the shape of the arterial time-concentration curve produced by the intravenous injection of iodinated contrast media. If contrast media appears in the arterial circulation as a compact bolus and reaches a high peak, images containing low or no iodine (the mask image or images) and high iodine concentration (the enhanced image or images) can be obtained close together in time, maximizing contrast media enhancement and minimizing the potential for spatial movement (misregistration). However, if the contrast media bolus is broad, rising slowly to a low concentration peak, sufficient time may pass for movement to occur and the opacification difference between the mask image and the enhanced image may be too small to visualize vessels of interest. Consequently, knowledge of the rules which govern the formation of time-concentration curves is central to IV-DSA

  4. Coronary arterial Disease associated with arteriosclerosis in lower extremity: Angiographic analysis

    International Nuclear Information System (INIS)

    Kim, Ji Hye; Chung, Jin Wook; Lee, Seon Kyu; Han, Joon Koo; Park, Jae Hyung; Kim, Jae Seung; Han, Man Chung

    1993-01-01

    We performed both peripheral and coronary angiographies in 52 patients with an arteriosclerosis in lower extremities. The severity of arteriosclerotic narrowing of the coronary and peripheral arteries were compared on angiographies. An angiographic vascular score(AVS, 0-5) reflecting the number and the degree of stenosis in 12 lower extremity arteries and three major coronary arteries was assigned to each angiogram and the sun of scores in the lower extremity arteries was compared with the incidence of significant coronary artery disease (more than grade 3) and coronary score. Relation of incidence and severity of vascular stenosis and risk factors (diabetes metallitus, hypertension, smoking, and hypercholesterolemia) was also analyzed. Thirty-four of 52 patients (65%) had an angiographically significant coronary artery disease. Thirteen of these 34 patients (38%) had no clinical symptom and sign of the ischemic heart disease. There was no statistically significant difference in the incidence and severity of coronary artery disease between high (more than 30) and low AVS group in lower extremity (p>0.14). All patients had at least one risk factor and 49 of 52 patients (94%) had multiple risk factors. Coronary angiography was normal in there patients with only one risk factors, and angiographically significant coronary artery disease existed in nine of 16 cases (56.3%) with two risk factors. 13 of 17 case (76.5%) with three risk factors, and 12 of 16 cases (75.0%) with all four risk factors. There were no significant correlations between individual risk factors and incidence, severity of arteriosclerosis in coronary and lower extremity arteries. In conclusion, angiographic evaluation of the coronary artery disease in patients with lower extremity arteriosclerosis is necessary because of the high chance of coronary artery disease and difficulty in the prediction of coronary artery disease with a severity of the peripheral arteriosclerosis, presence of various risk

  5. Staff dosimetry and risk assessment during digestive and angiographic examinations

    International Nuclear Information System (INIS)

    Pages, J.; Osteaux, M.

    2001-01-01

    The use of ionizing radiation in medical applications involves not only a risk for the patient, but also for the staff which executed the related examinations. The dose to the forehead, neck, fingers and wrist of a radiologist and an assisting nurse were measured with thermoluminescent dosimeters during angiographic and digestive examinations respectively. Dose to eye lenses and effective dose were estimated for a working period of one year. Effective doses were under the established limit of 20 mSv per year. Nurse eye lens dose was higher than the limit of 150 mSv. Differences of a factor of 3.8 were observed between nurse and radiologist doses. Angiographic procedures are considered as high risk examinations, however, digestive examinations can have a higher risk than interventional procedures. (author)

  6. Evaluation of indicator dilution process in X-ray angiographic images deteriorated by factors of technical origin

    International Nuclear Information System (INIS)

    Dernalowicz, J.; Goszczynska, H.; Mazur, P.

    1996-01-01

    Different sources of error in X-rays angiographic images have been discussed. Some kind of error which considerably influences densitometric analysis of time sequences of images - the fluctuation of image intensity during coronarography screening - has been emphasized and discussed in details. Three practical solutions of how to correct (compensate) such error have been proposed and described. (author)

  7. The pharmaco-kinetics of angiographic contrast media with special reference to the extravascular spaces. Fundamental studies on dogs for the characterization of angiographic media. Pt. 1

    International Nuclear Information System (INIS)

    Lagemann, K.

    1975-01-01

    The pharmaco-kinetics of angiographic contrast media in the extra-vascular space, which are largely unknown, were investigated experimentally in dogs. As part of a basic study, using radio-active contrast media, it was possible to determine the concentration and rate of elimination in practically all organs and tissues. Measurements were carried out first after prolonged infusion of contrast under conditions of balanced flow, and secondly six hours after the end of the infusion. It was therefore possible to determine the inflow and loss of contrast medium in various organs, or organs systems. The most commonly used angiographic contrast media in Germany were investigated. Their kinetic behaviour is largely identical, their pattern of distribution and elimination depended principally on the organ or tissue. (orig.) [de

  8. Growth curve and diet density affect eating motivation, behaviour, and body composition of broiler breeders during rearing

    NARCIS (Netherlands)

    Mozos, de los J.; Garcia Ruiz, A.I.; Hartog, den L.A.; Villamide, M.J.

    2017-01-01

    The aim of this work has been to assess the effect of diet density [control (CON) or 15% diluted (DIL)] and growth curve [recommended by the genetic line (RBW) or 15% heavier (HBW)] and their interaction on BW uniformity, feeding motivation, behavior, and body composition of broiler breeder pullets.

  9. Optimal catalyst curves: Connecting density functional theory calculations with industrial reactor design and catalyst selection

    DEFF Research Database (Denmark)

    Jacobsen, C.J.H.; Dahl, Søren; Boisen, A.

    2002-01-01

    For ammonia synthesis catalysts a volcano-type relationship has been found experimentally. We demonstrate that by combining density functional theory calculations with a microkinetic model the position of the maximum of the volcano curve is sensitive to the reaction conditions. The catalytic...... ammonia synthesis activity, to a first approximation, is a function only of the binding energy of nitrogen to the catalyst. Therefore, it is possible to evaluate which nitrogen binding energy is optimal under given reaction conditions. This leads to the concept of optimal catalyst curves, which illustrate...... the nitrogen binding energies of the optimal catalysts at different temperatures, pressures, and synthesis gas compositions. Using this concept together with the ability to prepare catalysts with desired binding energies it is possible to optimize the ammonia process. In this way a link between first...

  10. String dynamics in curved space-time revisited

    International Nuclear Information System (INIS)

    Marrakchi, A.L.; Singh, L.P.

    1989-09-01

    The equations of motion of the general background of curved space-time, Einstein's equations, are derived simply by demanding the renormalized energy-momentum tensor of a bosonic string propagating in this background to be traceless. The energy-momentum tensor of such a string is then separable into a holomorphic and an antiholomorphic parts as a consequence of the conformal invariance of the theory regained at the quantum level. (author). 8 refs

  11. Spontaneous coronary artery dissection: complete angiographic resolution without stenting

    Directory of Open Access Journals (Sweden)

    Alexandre Abizaid

    2007-09-01

    Full Text Available A case of spontaneous coronary artery dissection in a 49-year-oldwoman is presented. She did not present the classical cardiovascular riskfactors. Etiology and treatment are discussed. She underwent primarypercutaneous coronary intervention of the left anterior descendingartery with no stenting and had complete angiographic resolution.

  12. Mesenteric Castleman's disease: ultrasound, computed tomography and angiographic appearance

    International Nuclear Information System (INIS)

    Malara, F.A.; Price, D.; Fabiny

    2000-01-01

    The localized form of Castleman's disease is rare, and a mesenteric location is particularly unusual. A case of an asymptomatic young woman having the hyaline vascular type is presented and the ultrasound, computed tomography (CT) and angiographic features of the condition are demonstrated. Copyright (1999) Blackwell Science Pty Ltd

  13. Column Store for GWAC: A High-cadence, High-density, Large-scale Astronomical Light Curve Pipeline and Distributed Shared-nothing Database

    Science.gov (United States)

    Wan, Meng; Wu, Chao; Wang, Jing; Qiu, Yulei; Xin, Liping; Mullender, Sjoerd; Mühleisen, Hannes; Scheers, Bart; Zhang, Ying; Nes, Niels; Kersten, Martin; Huang, Yongpan; Deng, Jinsong; Wei, Jianyan

    2016-11-01

    The ground-based wide-angle camera array (GWAC), a part of the SVOM space mission, will search for various types of optical transients by continuously imaging a field of view (FOV) of 5000 degrees2 every 15 s. Each exposure consists of 36 × 4k × 4k pixels, typically resulting in 36 × ˜175,600 extracted sources. For a modern time-domain astronomy project like GWAC, which produces massive amounts of data with a high cadence, it is challenging to search for short timescale transients in both real-time and archived data, and to build long-term light curves for variable sources. Here, we develop a high-cadence, high-density light curve pipeline (HCHDLP) to process the GWAC data in real-time, and design a distributed shared-nothing database to manage the massive amount of archived data which will be used to generate a source catalog with more than 100 billion records during 10 years of operation. First, we develop HCHDLP based on the column-store DBMS of MonetDB, taking advantage of MonetDB’s high performance when applied to massive data processing. To realize the real-time functionality of HCHDLP, we optimize the pipeline in its source association function, including both time and space complexity from outside the database (SQL semantic) and inside (RANGE-JOIN implementation), as well as in its strategy of building complex light curves. The optimized source association function is accelerated by three orders of magnitude. Second, we build a distributed database using a two-level time partitioning strategy via the MERGE TABLE and REMOTE TABLE technology of MonetDB. Intensive tests validate that our database architecture is able to achieve both linear scalability in response time and concurrent access by multiple users. In summary, our studies provide guidance for a solution to GWAC in real-time data processing and management of massive data.

  14. Quantum field theory in curved space-time

    International Nuclear Information System (INIS)

    Najmi, A.-H.

    1982-09-01

    The problem of constructing states for quantum field theories in nonstationary background space-times is set out. A formalism in which the problem of constructing states can be attacked more easily than at present is presented. The ansatz of energy-minimization as a means of constructing states is formulated in this formalism and its general solution for the free scalar field is found. It has been known, in specific cases, that such states suffer from the problem of unitary inequivalence (the pathology). An example in Minowski space-time is presented in which global operators, such as the particle-number operator, do not exist but all physical observables, such as the renormalized energy density are finite. This model has two Fock-sectors as its space of physical states. A simple extension of this model, i.e. enlarging the Fock-space of states is found not to remedy the pathology: in a Robertson-Walker space-time the quantum field acquires an infinite amount of renormalized energy density to the future of the hypersurface on which the energy density is minimized. Finally, the solution of the ansatz of energy minimization for the free, massive Hermitian fermion field is presented. (author)

  15. Early Angiographic Resolution of Cerebral Vasospasm with High Dose Intravenous Milrinone Therapy

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2015-01-01

    Full Text Available Background. Treatment of symptomatic delayed cerebral ischemia (DCI after subarachnoid hemorrhage (SAH is difficult. Recent studies suggest intravenous (IV high dose milrinone as a potential therapy. The timing to angiographic response with this is unclear. Methods. We reviewed the chart of one patient admitted for SAH who developed symptomatic DCI and was treated with high dose IV milrinone. Results. A 66-year-old female was admitted with a Hunt and Hess clinical grade 4, World Federation of Neurological Surgeons (WFNS clinical grade 4, and SAH secondary to a left anterior choroidal artery aneurysm which was clipped. After bleed day 6, the patient developed symptomatic DCI. We planned for angioplasty of the proximal segments. We administered high dose IV milrinone bolus followed by continuous infusion which led to clinical improvement prior to angiography. The angiogram performed 1.5 hours after milrinone administration displayed resolution of the CT angiogram and MRI based cerebral vasospasm such that further intra-arterial therapy was aborted. She completed 6 days of continuous IV milrinone therapy, was transferred to the ward, and subsequently rehabilitated. Conclusions. High dose IV milrinone therapy for symptomatic DCI after SAH can lead to rapid neurological improvement with dramatic early angiographic improvement of cerebral vasospasm.

  16. Quantum fields in curved space-times

    International Nuclear Information System (INIS)

    Ashtekar, A.; Magnon, A.

    1975-01-01

    The problem of obtaining a quantum description of the (real) Klein-Gordon system in a given curved space-time is discussed. An algebraic approach is used. The *-algebra of quantum operators is constructed explicitly and the problem of finding its *-representation is reduced to that of selecting a suitable complex structure on the real vector space of the solutions of the (classical) Klein-Gordon equation. Since, in a static space-time, there already exists, a satisfactory quantum field theory, in this case one already knows what the 'correct' complex structure is. A physical characterization of this 'correct' complex structure is obtained. This characterization is used to extend quantum field theory to non-static space-times. Stationary space-times are considered first. In this case, the issue of extension is completely straightforward and the resulting theory is the natural generalization of the one in static space-times. General, non-stationary space-times are then considered. In this case the issue of extension is quite complicated and only a plausible extension is presented. Although the resulting framework is well-defined mathematically, the physical interpretation associated with it is rather unconventional. Merits and weaknesses of this framework are discussed. (author)

  17. Angiographic diagnosis of hemorrhage tumours of the small intestine

    International Nuclear Information System (INIS)

    Vadon, G.; Ehngloner, L.; Petri, K.

    1980-01-01

    2 angiographic investigations in small intestine tumors, accompanied with hemorrhage are considered. Conclusion is made that the most suitable moment for estimation of small intestine hemorrhage, according to the proper and literature data, is selective angiography. Wide application of the technique for preoperative detection of gastro-inestinal hemorrhage is recommended

  18. Angiographic features of 26 children with Takayasu's arteritis

    International Nuclear Information System (INIS)

    McCulloch, M.; Goddard, E.; Sinclair, P.; Andronikou, S.; Mandelstam, S.; Beningfield, S.J.; Lawrenson, J.; Millar, A.J.W.

    2003-01-01

    Background: Takayasu's arteritis (TA) is a chronic idiopathic inflammatory disease affecting primarily the aorta, its proximal branches and the pulmonary arteries Objectives: To retrospectively review the angiograms of children with TA so as to describe the patterns of vascular involvement. Patients and methods: Twenty-six children with TA who differed from most other studies in that almost all of them presented with hypertension, reflecting the incidence of abdominal aortic and renal artery involvement. Results: The most consistent finding was stenosis of the aorta. Marginal irregularity/undulation of the aorta was also a useful angiographic diagnostic feature in subtle disease. The incidence of aneurysms was high compared to other studies and both fusiform and saccular aneurysms were encountered. Percutaneous transluminal angioplasty (PTA) was successful in all eight patients in whom it was performed. MRI, CT angiography and US are discussed as less invasive imaging alternatives. TA is a significant cause of renovascular hypertension in children in South Africa where there is a high incidence of tuberculous infection. Knowledge of the angiographic features and pattern of aortic involvement is essential for diagnosis and initiation of early and appropriate treatment, including PTA. (orig.)

  19. Evaluation of left ventricular diastolic function by appreciating the shape of time activity curve

    International Nuclear Information System (INIS)

    Nishimura, Tohru; Taya, Makoto; Shimoyama, Katsuya; Sasaki, Akira; Mizuno, Haruyoshi; Tahara, Yorio; Ono, Akifumi; Ishikawa, Kyozo

    1993-01-01

    To determine left ventricular diastolic function (LVDF), the shape of time activity curve and primary differential curve, as acquired by Tc-99m radionuclide angiography, were visually assessed. The study popoulation consisted of 1647 patients with heart disease, such as hypertension, ischemic heart disease, cardiomyopathy and valvular disease. Fifty-six other patients were served as controls. The LVDF was divided into 4 degrees: 0=normal, I=slight disturbance, II=moderate disturbance, and III=severe disturbance. LVDF variables, including time to peak filling (TPF), TPF/time to end-systole, peak filling rate (PFR), PFR/t, 1/3 filling fraction (1/3 FR), and 1/3 FR/t, were calculated from time activity curve. There was no definitive correlation between each variable and age or heart rate. Regarding these LVDF variables, except for 1/3 FR, there was no significant difference between the group 0 of heart disease patients and the control group. Among the groups 0-III of heart disease patients, there were significant difference in LVDF variables. Visual assessement concurred with left ventricular ejection fraction, PFR/end-diastolic curve, and filling rate/end-diastolic curve. Visual assessment using time activity curve was considered useful in the semiquantitative determination of early diastolic function. (N.K.)

  20. Tracer concentration curves and residence time analysis in technological flow systems. 2

    International Nuclear Information System (INIS)

    Pippel, W.

    1976-01-01

    Tracer concentration curves measured in flow systems by means of radioactive isotopes are treated as a two dimensional random process. Comparing them with the family distribution functions described in part I, it follows that only in case of ergodic behaviour of the system tracer curves can be considered as age distribution functions. The conception of ergodicity in residence time systems has been explained with the aid of a time function measurable by a special method of radioactive tracer technique and by the mean value of the residence time obtainable from this function. Furthermore, technological consequences in evaluating tracer concentration curves of real flow systems are discussed with respect to supposed ergodic or nonergodic behaviour. These considerations are of special importance for flow systems with temporary fluctuations in structure. (author)

  1. A standard curve based method for relative real time PCR data processing

    Directory of Open Access Journals (Sweden)

    Krause Andreas

    2005-03-01

    Full Text Available Abstract Background Currently real time PCR is the most precise method by which to measure gene expression. The method generates a large amount of raw numerical data and processing may notably influence final results. The data processing is based either on standard curves or on PCR efficiency assessment. At the moment, the PCR efficiency approach is preferred in relative PCR whilst the standard curve is often used for absolute PCR. However, there are no barriers to employ standard curves for relative PCR. This article provides an implementation of the standard curve method and discusses its advantages and limitations in relative real time PCR. Results We designed a procedure for data processing in relative real time PCR. The procedure completely avoids PCR efficiency assessment, minimizes operator involvement and provides a statistical assessment of intra-assay variation. The procedure includes the following steps. (I Noise is filtered from raw fluorescence readings by smoothing, baseline subtraction and amplitude normalization. (II The optimal threshold is selected automatically from regression parameters of the standard curve. (III Crossing points (CPs are derived directly from coordinates of points where the threshold line crosses fluorescence plots obtained after the noise filtering. (IV The means and their variances are calculated for CPs in PCR replicas. (V The final results are derived from the CPs' means. The CPs' variances are traced to results by the law of error propagation. A detailed description and analysis of this data processing is provided. The limitations associated with the use of parametric statistical methods and amplitude normalization are specifically analyzed and found fit to the routine laboratory practice. Different options are discussed for aggregation of data obtained from multiple reference genes. Conclusion A standard curve based procedure for PCR data processing has been compiled and validated. It illustrates that

  2. Comparison of intravascular ultrasound and angiographic assessement of coronary reference segment size in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2008-01-01

    During percutaneous coronary intervention, the reference segment is assessed angiographically. This report described the discrepancy between angiographic and intravascular ultrasound (IVUS) assessment of reference segment size in patients with type 2 diabetes mellitus. Preintervention IVUS was used...... to study 62 de novo lesions in 41 patients with type 2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal-looking segments within 5 mm proximal and distal to the lesion. Plaque burden...... was measured as plaque CSA/external elastic membrane (EEM) CSA. Using IVUS, the reference lumen diameter was 2.80 +/- 0.42 mm and the reference EEM diameter was 4.17 +/- 0.56 mm. The angiographic reference diameter was 2.63 +/- 0.36 mm. Mean difference between the IVUS EEM diameter and angiographic reference...

  3. Spontaneous symmetry breaking in curved space-time

    International Nuclear Information System (INIS)

    Toms, D.J.

    1982-01-01

    An approach dealing with some of the complications which arise when studying spontaneous symmetry breaking beyond the tree-graph level in situations where the effective potential may not be used is discussed. These situations include quantum field theory on general curved backgrounds or in flat space-times with non-trivial topologies. Examples discussed are a twisted scalar field in S 1 xR 3 and instabilities in an expanding universe. From these it is seen that the topology and curvature of a space-time may affect the stability of the vacuum state. There can be critical length scales or times beyond which symmetries may be broken or restored in certain cases. These features are not present in Minkowski space-time and so would not show up in the usual types of early universe calculations. (U.K.)

  4. SUPERLUMINOUS SUPERNOVAE POWERED BY MAGNETARS: LATE-TIME LIGHT CURVES AND HARD EMISSION LEAKAGE

    International Nuclear Information System (INIS)

    Wang, S. Q.; Wang, L. J.; Dai, Z. G.; Wu, X. F.

    2015-01-01

    Recently, research performed by two groups has revealed that the magnetar spin-down energy injection model with full energy trapping can explain the early-time light curves of SN 2010gx, SN 2013dg, LSQ12dlf, SSS120810, and CSS121015 but fails to fit the late-time light curves of these superluminous supernovae (SLSNe). These results imply that the original magnetar-powered model is challenged in explaining these SLSNe. Our paper aims to simultaneously explain both the early- and late-time data/upper limits by considering the leakage of hard emissions. We incorporate quantitatively the leakage effect into the original magnetar-powered model and derive a new semianalytical equation. Comparing the light curves reproduced by our revised magnetar-powered model with the observed data and/or upper limits of these five SLSNe, we found that the late-time light curves reproduced by our semianalytical equation are in good agreement with the late-time observed data and/or upper limits of SN 2010gx, CSS121015, SN 2013dg, and LSQ12dlf and the late-time excess of SSS120810, indicating that the magnetar-powered model might be responsible for these SLSNe and that the gamma-ray and X-ray leakages are unavoidable when the hard photons were down-Comptonized to softer photons. To determine the details of the leakage effect and unveil the nature of SLSNe, more high-quality bolometric light curves and spectra of SLSNe are required

  5. Imaginary time density-density correlations for two-dimensional electron gases at high density

    Energy Technology Data Exchange (ETDEWEB)

    Motta, M.; Galli, D. E. [Dipartimento di Fisica, Università degli Studi di Milano, Via Celoria 16, 20133 Milano (Italy); Moroni, S. [IOM-CNR DEMOCRITOS National Simulation Center and SISSA, Via Bonomea 265, 34136 Trieste (Italy); Vitali, E. [Department of Physics, College of William and Mary, Williamsburg, Virginia 23187-8795 (United States)

    2015-10-28

    We evaluate imaginary time density-density correlation functions for two-dimensional homogeneous electron gases of up to 42 particles in the continuum using the phaseless auxiliary field quantum Monte Carlo method. We use periodic boundary conditions and up to 300 plane waves as basis set elements. We show that such methodology, once equipped with suitable numerical stabilization techniques necessary to deal with exponentials, products, and inversions of large matrices, gives access to the calculation of imaginary time correlation functions for medium-sized systems. We discuss the numerical stabilization techniques and the computational complexity of the methodology and we present the limitations related to the size of the systems on a quantitative basis. We perform the inverse Laplace transform of the obtained density-density correlation functions, assessing the ability of the phaseless auxiliary field quantum Monte Carlo method to evaluate dynamical properties of medium-sized homogeneous fermion systems.

  6. CT and angiographic appearances of hepatocellular carcinoma partially fed by right inferior phrenic artery

    Energy Technology Data Exchange (ETDEWEB)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu [Tokyo Univ. (Japan). Faculty of Medicine

    1983-04-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially fed by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery.

  7. CT and angiographic appearances of hepatocellular carcinoma partially feeded by right inferior phrenic artery

    International Nuclear Information System (INIS)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu

    1983-01-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially feeded by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery. (author)

  8. The pretzel sign: angiographic pattern of tortuous intra-aneurysmal blood flow in a giant serpentine aneurysm.

    LENUS (Irish Health Repository)

    Fanning, N F

    2012-02-03

    Giant serpentine aneurysms (GSAs) form a specific subgroup of giant cerebral aneurysms that have pathognomonic angiographic features. We report the angiographic findings of a GSA demonstrating a striking convoluted dynamic flow pattern, which we have called the \\'pretzel sign\\'. The aneurysm was successfully treated by permanent occlusion of the parent vessel using a detachable balloon. GSAs should be identified prior to treatment in view of their particular management requirements.

  9. The value of regional wall motion abnormalities on gated mycardiac perfusion imaging in perfusion imaging in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Yao Lixin; Liu Binbin

    2007-01-01

    Objective: To determine the possible level of angiographic stenoses of coronary artery at which reversible regional wall motion abnormalities (RWMA) are present on 99m Tc-sestamibi ( 99m Tc-MIBI)-gated myocardial perfusion imaging (MPI). Methods: ninty patients undergoing coronary angiography MPI within two weeks were recruited. A five grades and nine segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 64%,with a specificity of 95% and positive predictive value of 97%. The presence of reversible RWMA was able to stratify patients with severe angiographic stenoses of 75% or more from those less than 75% with high positive predictive value. A good correlation was noted between the presence of reversible RWMA and the coronary artery jeopardy score. Multivariate analysis showed that the post-stress RWMA and reversible RWMA scores and positive dipyridamole-stress exercise electrocardiogram(ECG) were significant predictors of angiographic severity. Conclusions: Reversible RWMA, as shown by dipyridamole stress 99m Tc-MIBI MPI, is a significant predictor of angiographic disease with very high specificity and adds incremental value to MPI for the assessment of angiographic severity. (authors)

  10. Variations of Patient Doses in Interventional Examinations at Different Angiographic Units

    International Nuclear Information System (INIS)

    Bor, Dogan; Toklu, Tuerkay; Olgar, Turan; Sancak, Tanzer; Cekirge, Saruhan; Onal, Baran; Bilgic, Sadik

    2006-01-01

    Purpose. We analyzed doses for various angiographic procedures using different X-ray systems in order to assess dose variations. Methods. Dose-area product (DAP), skin doses from thermoluminescent dosimeters and air kerma measurements of 308 patients (239 diagnostic and 69 interventional) were assessed for five different angiographic units. All fluoroscopic and radiographic exposure parameters were recorded online for single and multiprojection studies. Radiation outputs of each X-ray system were also measured for all the modes of exposure using standard protocols for such measurements. Results. In general, the complexity of the angiographic procedure was found to be the most important reason for high radiation doses. Skill of the radiologist, management of the exposure parameters and calibration of the system are the other factors to be considered. Lateral cerebral interventional studies carry the highest risk for deterministic effects on the lens of the eye. Effective doses were calculated from DAP measurements and maximum fatal cancer risk factors were found for carotid studies. Conclusions. Interventional radiologists should measure patient doses for their examinations. If there is a lack of necessary instrumentation for this purpose, then published dose reports should be used in order to predict the dose levels from some of the exposure parameters. Patient dose information should include not only the measured quantity but also the measured radiation output of the X-ray unit and exposure parameters used during radiographic and fluoroscopic exposures

  11. Renormalization of the δ expansion in curved space-time

    International Nuclear Information System (INIS)

    Cho, H.T.

    1991-01-01

    Renormalization of a recently proposed δ expansion for a self-interacting scalar field theory in curved space-time is examined. The explicit calculation is carried out up to order δ 2 , which indicates that the expansion is renormalizable, but reduces to essentially the λφ 4 theory when the cutoff is removed. A similar conclusion has been reached in a previous paper where the case of flat space-time is considered

  12. Transmission assets investment timing using net present value curves

    International Nuclear Information System (INIS)

    Garcia, Reinaldo C.; Contreras, Javier; Correia, Pedro F.; Munoz, Jose I.

    2010-01-01

    Improvement and expansion of the transmission grid is still an unresolved issue in the new competitive environment. In current electricity markets, transmission lines have become assets that need financial instruments for investors who wish to ensure steady long-term returns and to withstand short-term market volatility. The timing and the combination of new transmission investments is key to analyze their long-term effects. This paper presents the concept of net present value (NPV) curve to estimate the best investment time for the investor, where the curve is constructed by calculating the NPVs resulting from the investment in successive years. A specific contract model based on financial transmission rights (FTR) is used for the NPV evaluation of transmission assets, and the stochastic properties of all variables related to the investment market structure are considered. The model is applied to the IEEE 24-bus Reliability Test System (RTS) showing the approach capabilities as a decision-aid tool for transmission investors.

  13. Laws governing the energy conversion of ionization curves

    International Nuclear Information System (INIS)

    Gorgoskii, V.I.

    1986-01-01

    The author attempts to determine if ionization curves are structured or smooth, the cause of the smoothing of the curves, the possibility of the curves having maxima and why, how many maxima are on the ionization curve, and which of these maxima is the fundamental maxima. The study shows that ionization curves without and additional maximum, i.e., with one fundamental maximum, can be obtained for potassium, rubidium, and cesium. This requires reduction of the density of the electrons in the stream and the density of the atoms of the target gas. It is also shown that in order to obtain ionization curves with additional maxima in the cases of neon, argon, and krypton, the measurements must be carried out at high densities of the electrons in the stream and of the atoms of the target gas

  14. Global Population Density Grid Time Series Estimates

    Data.gov (United States)

    National Aeronautics and Space Administration — Global Population Density Grid Time Series Estimates provide a back-cast time series of population density grids based on the year 2000 population grid from SEDAC's...

  15. AGAINST THE WIND: RADIO LIGHT CURVES OF TYPE IA SUPERNOVAE INTERACTING WITH LOW-DENSITY CIRCUMSTELLAR SHELLS

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Chelsea E.; Nugent, Peter E.; Kasen, Daniel N., E-mail: chelseaharris@berkeley.edu [Astronomy Department, University of California Berkeley, Berkeley, CA (United States)

    2016-06-01

    For decades a wide variety of observations spanning the radio through optical and on to the X-ray have attempted to uncover signs of type Ia supernovae (SNe Ia) interacting with a circumstellar medium (CSM). The goal of these studies is to constrain the nature of the hypothesized SN Ia mass-donor companion. A continuous CSM is typically assumed when interpreting observations of interaction. However, while such models have been successfully applied to core-collapse SNe, the assumption of continuity may not be accurate for SNe Ia, because shells of CSM could be formed by pre-supernova eruptions (novae). In this work, we model the interaction of SNe with a spherical, low-density, finite-extent CSM and create a suite of synthetic radio synchrotron light curves. We find that CSM shells produce sharply peaked light curves. We also identify a fiducial set of models that obey a common evolution and can be used to generate radio light curves for an interaction with an arbitrary shell. The relations obeyed by the fiducial models can be used to deduce CSM properties from radio observations; we demonstrate this by applying them to the nondetections of SN 2011fe and SN 2014J. Finally, we explore a multiple shell CSM configuration and describe its more complicated dynamics and the resultant radio light curves.

  16. Growth curve and diet density affect eating motivation, behavior, and body composition of broiler breeders during rearing.

    Science.gov (United States)

    de Los Mozos, J; García-Ruiz, A I; den Hartog, L A; Villamide, M J

    2017-08-01

    The aim of this work has been to assess the effect of diet density [control (CON) or 15% diluted (DIL)] and growth curve [recommended by the genetic line (RBW) or 15% heavier (HBW)] and their interaction on BW uniformity, feeding motivation, behavior, and body composition of broiler breeder pullets. A total of 3,000 one-day-old female breeders Ross 308, distributed in 20 pens, was randomly assigned to each treatment. Feed allowance was weekly adjusted to reach the desired BW. Feed was provided as pelleted (zero to 3 wk) and crumble (4 to 19 wk). Time eating was measured at 7, 11, and 19 weeks. A feeding rate test was performed after 11 weeks. Behavior was observed at 9 and 15 wk, by visual scan. At 6, 13, and 19 wk of age, one bird/pen was slaughtered for weighing different organs and analyzing the composition of empty whole bodies. Treatments did not affect BW uniformity; relative weights of the ovary, oviduct, or gizzard; or protein content of empty BW. Time eating varied with the growth curve at 19 wk (P motivation. Behavior was affected by the age and by the time of the d measured, but it did not change with the treatments. Birds spent most time pecking objects (50%), feeding (28%), and drinking (17%). Pullets fed DIL had 8% lower breast yield at different ages and higher empty digestive tracts at 6 weeks. Body composition varied with age; fat content increased from 12.7 to 15.9 to 19.8% for 6, 13, and 19 wk, respectively. The lowest body fat was observed for RBW pullets fed DIL (P = 0.003) at 19 weeks. Feeding DIL diets to HBW pullets could be done to increase the time spent eating and reduce their feeling of hunger without negative effects on body composition. However, its influence on behavior and BW uniformity was not proved. © The Author 2017. Published by Oxford University Press on behalf of Poultry Science Association.

  17. Analysis on the time/activity curve of salivary gland scintigraphy in salivary gland diseases; The correlation between the pattern of time/activity curve and the amount of saliva

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazufumi; Hosokawa, Yoichiro; Kaneko, Masanori; Ohmori, Keiichi; Minowa, Kazuyuki; Fukuda, Hiroshi; Yamasaki, Michio (Hokkaido Univ., Sapporo (Japan). School of Dentistry)

    1992-04-01

    Salivary gland scintigraphy with {sup 99m}TcO{sub 4}{sup -} is a simple method to evaluate salivary gland function and has been available as a technique using a time/activity curve for a number of years. But, there were few reports on the relationship between the various patterns of the time/activity curves and the salivary flow rate from the gland. This presents correlation between the time/activity curve pattern and the salivary flow rate from the parotid gland. Sixty-five patients complaining of xerostomia were examined. Sixty-two were female and 3 male (average age 45.6 years, range 17-69 years). Their diagnosis were 26 Sjoegren Syndrome, 28 suspicion of Sjoegren Syndrome and 11 parotiditis. The salivary flow rate from parotid gland was measured by stimulation with 10% citric acid using modified Carlson crittenden cup every 10 seconds for 5 min. 185 MBq {sup 99m}TcO{sub 4}{sup -} was injected intravenously and sequential scintigraphy was performed. Time/activity curves were recorded on film. Six kinds of basic patterns were as follows: normal pattern, median pattern, flat pattern and sloped pattern (Mita et al 1981), reaccumulation flat pattern and poor secretion (Stimulant secretory ratio: less than 70%) pattern by us. The amount of saliva was as follows: normal pattern (n=31), 5.4+0.4 ml; reaccumulation flat pattern (n=3), 4.2+0.6 ml; poor secretion pattern (n=18), 4.1+0.5 ml; median pattern (n=20), 3.5+0.5 ml; flat pattern (n=11), 2.6+0.5 ml and sloped pattern (n=1), 1.5 ml. Normal pattern versus poor secretion pattern, median pattern and flat pattern in the salivary flow rate were statistically significant as determined by Students' t-test. We assessed the correlation between the pattern of time/activity curve in the salivary gland scintigraphy and the amount of saliva. (author).

  18. The zero-wall puncture: a novel angiographic puncture technique with substantial benefits

    International Nuclear Information System (INIS)

    Leswick, D.A.; Szkup, P.; Stoneham, G.W.

    2005-01-01

    Medical education can be busy, exhausting, and stressful, with potential adverse effects on trainees' physical and mental health. Radiology residency is no exception. In addition to increased daily workload and study requirements, Canadian radiology residents are performing a diverse and increasing number of emergent diagnostic examinations after hours. In an attempt to improve resident self-worth and efficiency during angiographic rotations, we investigated the effects of a novel angiographic puncture procedure on various resident lifestyle indexes. Standard techniques for accessing the femoral artery are either the single-wall puncture or double-wall puncture (Seldinger technique). Both of these techniques are widely known and practiced. Following procedure completion, hemostasis must be achieved at the puncture site. This has traditionally required manual compression at the puncture site, which may require 15 to 20 minutes. At our institution the standard policy is that 'whoever makes the puncture, compresses the groin,' also known as 'you broke it, you fix it'. This has prompted our industrious resident complement to develop a novel, previously undescribed, angiographic puncture technique known as the 'zero-wall puncture technique.' Preliminary unpublished results from our institution show that when residents employ the zero-wall puncture technique the attending staff radiologist subsequently both performs the puncture and compresses the groin at the end of the procedure. We investigated the effect of zero-wall puncture on various resident lifestyle indexes. (author)

  19. Time Alignment as a Necessary Step in the Analysis of Sleep Probabilistic Curves

    Science.gov (United States)

    Rošt'áková, Zuzana; Rosipal, Roman

    2018-02-01

    Sleep can be characterised as a dynamic process that has a finite set of sleep stages during the night. The standard Rechtschaffen and Kales sleep model produces discrete representation of sleep and does not take into account its dynamic structure. In contrast, the continuous sleep representation provided by the probabilistic sleep model accounts for the dynamics of the sleep process. However, analysis of the sleep probabilistic curves is problematic when time misalignment is present. In this study, we highlight the necessity of curve synchronisation before further analysis. Original and in time aligned sleep probabilistic curves were transformed into a finite dimensional vector space, and their ability to predict subjects' age or daily measures is evaluated. We conclude that curve alignment significantly improves the prediction of the daily measures, especially in the case of the S2-related sleep states or slow wave sleep.

  20. IMPORTANCE OF KNOWING ANGIOGRAPHIC CHARACTERISTICS OF THE TENSOR FASCIAE LATAE VASCULAR STALK

    Directory of Open Access Journals (Sweden)

    Sladjana Ugrenovic

    2006-07-01

    Full Text Available Atherosclerosis is the most important and most common type of arteriosclerosis and is a general term for several diseases in which the artery wall becomes thicker and less elastic. The most common location of atherosclerosis occurrence is arteries of lower extremities, while arteries of upper extremities as well as visceral arteries are far less and far rarely affected with this degenerative process.The most frequent ones are occlusive changes on bifurcation of the abdominal aorta (aortoiliac obstructive atherosclerosis “Morbus Leriche”, trunk of the femoral artery and initial part of the popliteal artery (femoropopliteal obstructive atherosclerosis.Angiography, as additional method in medicine, gives the most precise insight into anatomical changes on blood vessels. With intention of estimating the possibility of using a slice (lobe part of the tensor fasciae latae (m. TFL in plastic and reconstructive surgery, we have analyzed 50 angiograms of femoral artery. The first group included Morbus Leriche patients (25 analyzed angiographics, while the second one comprised patients with femoropopliteal segment disease (also 25 analyzed angiographics. With angiographic analysis of the lateral femoral circumflex artery (LCFA and its branch, which is dominant in vascularisation of m. TFL slice, we discovered that the diameter of its source, as well as of its branches, is bigger in cases of femoropopliteal segment disease. Then, the reduction of the source diameter of LCFA and its branches, caused by vascular disease, leads to decreased blood supply of m. TFL, diminishing its quality and limiting its usage in surgery.In Morbus Leriche cases, m. TFL slice cannot be used in plastic and reconstructive surgery, its quality being decreased, due to poor vascularization. In femoropopliteal segment disease cases, thanks to normal blood supply, m. TFL slice can be widely used for reconstructions or covering of defects, especially in inguinal region, which is

  1. Correction of dynamic time-activity curves for gamma-camera dead time, radiotracer delivery, and radioactive decay: special considerations with ultrashort-lived radioisotopes

    International Nuclear Information System (INIS)

    Kuruc, A.; Zimmerman, R.E.; Treves, S.

    1985-01-01

    Time-vs.-activity curves obtained by using ultrashort-lived radioisotopes often need to be corrected for the effects of gamma-camera dead time and physical decay. Count loss due to gamma-camera dead time can be monitored by using an electronic oscillator incorporated into the gamma camera. Two algorithms that use this information to correct time-activity curves are discussed. It is also shown that the effect of physical decay on a time-activity curve is dependent on the time course of delivery of the radioisotope to the organ of interest. A mathematical technique that corrects physical decay is described

  2. Surgical Management of Juvenile Nasopharyngeal Angiofibroma Without Angiographic Embolization

    Directory of Open Access Journals (Sweden)

    Raja Ahmad

    2008-10-01

    Full Text Available Juvenile nasopharyngeal angiofibroma (JNA is a rare benign neoplasm that occurs almost exclusively in the nasopharynx of adolescent males. Surgery remains the primary treatment of choice. JNA has always presented a management challenge to surgeons because of its vascular nature, site of occurrence, and local tissue destruction. The surgical approaches are either standard open method which include external or intraoral incisions, or the recent advanced approach, i.e. via using the endonasal endoscope. It is widely accepted that the use of preoperative angiographic embolization reduces the occurrence of intraoperative bleeding and facilitates tumour removal. However, angiographic embolization is not available at all centres. The purpose of this article is to present our experience with five patients diagnosed with JNA who were resected without embolization, using various surgical approaches. Two tumours were removed via endonasal endoscopic surgery. None of the tumours were embolized prior to surgery. We highlight the preoperative evaluation of tumour extent, using both computed tomography (CT and magnetic resonance angiography, and the importance of temporary clamping of the external carotid artery intraoperatively. Our results suggest that the latter procedure is a safe and effective means of facilitating surgery and reducing intraoperative bleeding.

  3. Intractable Postpartum Bleeding: A Comparison of the Retrospective Analysis of Angiographic Findings and Transcatheter Arterial Embolization According to Delivery Pattern

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Eun Jung; Kim, Young Hwan; Kim, Si Hyung; Choi, Jin Soo; Park, Jun Cheol; Kwon, Sang Hun; Jo, Chi Heum; Cha, Soon Do [Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2008-12-15

    We evaluated the technical aspect and efficacy of transcatheter arterial embolization (TAE) in cases of intractable postpartum bleeding by comparing the angiographic findings women patients according to their delivery pattern. Between July of 2003 and March of 2008, 55 female patients were enrolled in this study. Of the 55 patients, 36 underwent a vaginal delivery (group 1), whereas 19 underwent a cesarean section delivery (group 2). We retrospectively evaluated the angiographic findings and the embolization technique between groups, using a Pearson Chi-Square test. Medical records and telephone interview findings were also reviewed to evaluate the efficacy of TAE and the outcome of fertility. Significantly greater positive angiographic findings were found in group 2 (63.2%) relative to group 1 (30.6%). For positive angiographic findings, except for AVM, the embolization was performed using coil or glue with gelfoam. For the negative angiographic findings or AVM, the gelfoam was the only embolic agent used. In all patients except for one, bleeding stopped after embolization. Major complications occurred in 2 patients only, and included uterine synechia and perforation. All patients except for one recovered after menstruation. In total, four patients became pregnant and one patient delivered a healthy infant. Positive angiographic findings requiring embolization with coil or glue, as well as gelfoam, were more commonly encountered in group 2 than in group 1. Based on the outcome of the study group, TAE is a safe and effective treatment for intractable postpartum bleeding and is also useful for preserving fertility.

  4. Intractable Postpartum Bleeding: A Comparison of the Retrospective Analysis of Angiographic Findings and Transcatheter Arterial Embolization According to Delivery Pattern

    International Nuclear Information System (INIS)

    Ahn, Eun Jung; Kim, Young Hwan; Kim, Si Hyung; Choi, Jin Soo; Park, Jun Cheol; Kwon, Sang Hun; Jo, Chi Heum; Cha, Soon Do

    2008-01-01

    We evaluated the technical aspect and efficacy of transcatheter arterial embolization (TAE) in cases of intractable postpartum bleeding by comparing the angiographic findings women patients according to their delivery pattern. Between July of 2003 and March of 2008, 55 female patients were enrolled in this study. Of the 55 patients, 36 underwent a vaginal delivery (group 1), whereas 19 underwent a cesarean section delivery (group 2). We retrospectively evaluated the angiographic findings and the embolization technique between groups, using a Pearson Chi-Square test. Medical records and telephone interview findings were also reviewed to evaluate the efficacy of TAE and the outcome of fertility. Significantly greater positive angiographic findings were found in group 2 (63.2%) relative to group 1 (30.6%). For positive angiographic findings, except for AVM, the embolization was performed using coil or glue with gelfoam. For the negative angiographic findings or AVM, the gelfoam was the only embolic agent used. In all patients except for one, bleeding stopped after embolization. Major complications occurred in 2 patients only, and included uterine synechia and perforation. All patients except for one recovered after menstruation. In total, four patients became pregnant and one patient delivered a healthy infant. Positive angiographic findings requiring embolization with coil or glue, as well as gelfoam, were more commonly encountered in group 2 than in group 1. Based on the outcome of the study group, TAE is a safe and effective treatment for intractable postpartum bleeding and is also useful for preserving fertility

  5. Usefulness of angiographic embolization endoscopic metallic clip placement in patient with non-variceal upper gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Min Jae; Hwang, Cheol Mog; Kim, Ho Jun; Cho, Young Jun; Bae, Seok Hwan [Dept. of Radiology, Konyang University Hospital, Daejeon (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of); Kang, Chae Hoon [Dept. of Radiology, Inje University College of Medicine, Pusan Paik Hospital, Busan (Korea, Republic of)

    2013-08-15

    The aim of this study is to assess the usefulness of angiographic embolization after endoscopic metallic clip placement around the edge of non-variceal upper gastrointestinal bleeding ulcers. We have chosen 41 patients (mean age, 65.2 years) with acute bleeding ulcers (22 gastric ulcers, 16 duodenal ulcers, 3 malignant ulcers) between January 2010 and December 2012. We inserted metallic clips during the routine endoscopic treatments of the bleeding ulcers. Subsequent transcatheter arterial embolization was performed within 2 hours. We analyzed the angiographic positive rates, angiographic success rates and clinical success rates. Among the 41 patients during the angiography, 19 patients (46%) demonstrated active bleeding points. Both groups underwent embolization using microcoils, N-butyl-cyano-acrylate (NBCA), microcoils with NBCA or gelfoam particle. There are no statistically significant differences between these two groups according to which embolic materials are being used. The bleeding was initially stopped in all patients, except the two who experienced technical failures. Seven patients experienced repeated episodes of bleeding within two weeks. Among them, 4 patients were successful re-embolized. Another 3 patients underwent gastrectomy. Overall, clinical success was achieved in 36 of 41 (87.8%) patients. The endoscopic metallic clip placement was helpful to locate the correct target vessels for the angiographic embolization. In conclusion, this technique reduced re-bleeding rates, especially in patients who do not show active bleeding points.

  6. Usefulness of angiographic embolization endoscopic metallic clip placement in patient with non-variceal upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Yoon, Min Jae; Hwang, Cheol Mog; Kim, Ho Jun; Cho, Young Jun; Bae, Seok Hwan; Shin, Byung Seok; Ohm, Joon Young; Kang, Chae Hoon

    2013-01-01

    The aim of this study is to assess the usefulness of angiographic embolization after endoscopic metallic clip placement around the edge of non-variceal upper gastrointestinal bleeding ulcers. We have chosen 41 patients (mean age, 65.2 years) with acute bleeding ulcers (22 gastric ulcers, 16 duodenal ulcers, 3 malignant ulcers) between January 2010 and December 2012. We inserted metallic clips during the routine endoscopic treatments of the bleeding ulcers. Subsequent transcatheter arterial embolization was performed within 2 hours. We analyzed the angiographic positive rates, angiographic success rates and clinical success rates. Among the 41 patients during the angiography, 19 patients (46%) demonstrated active bleeding points. Both groups underwent embolization using microcoils, N-butyl-cyano-acrylate (NBCA), microcoils with NBCA or gelfoam particle. There are no statistically significant differences between these two groups according to which embolic materials are being used. The bleeding was initially stopped in all patients, except the two who experienced technical failures. Seven patients experienced repeated episodes of bleeding within two weeks. Among them, 4 patients were successful re-embolized. Another 3 patients underwent gastrectomy. Overall, clinical success was achieved in 36 of 41 (87.8%) patients. The endoscopic metallic clip placement was helpful to locate the correct target vessels for the angiographic embolization. In conclusion, this technique reduced re-bleeding rates, especially in patients who do not show active bleeding points.

  7. The energy-momentum operator in curved space-time

    International Nuclear Information System (INIS)

    Brown, M.R.; Ottewill, A.C.

    1983-01-01

    It is argued that the only meaningful geometrical measure of the energy-momentum of states of matter described by a free quantum field theory in a general curved space-time is that provided by a normal ordered energy-momentum operator. The finite expectation values of this operator are contrasted with the conventional renormalized expectation values and it is further argued that the use of renormalization theory is inappropriate in this context. (author)

  8. 3-D time-domain induced polarization tomography: a new approach based on a source current density formulation

    Science.gov (United States)

    Soueid Ahmed, A.; Revil, A.

    2018-04-01

    Induced polarization (IP) of porous rocks can be associated with a secondary source current density, which is proportional to both the intrinsic chargeability and the primary (applied) current density. This gives the possibility of reformulating the time domain induced polarization (TDIP) problem as a time-dependent self-potential-type problem. This new approach implies a change of strategy regarding data acquisition and inversion, allowing major time savings for both. For inverting TDIP data, we first retrieve the electrical resistivity distribution. Then, we use this electrical resistivity distribution to reconstruct the primary current density during the injection/retrieval of the (primary) current between the current electrodes A and B. The time-lapse secondary source current density distribution is determined given the primary source current density and a distribution of chargeability (forward modelling step). The inverse problem is linear between the secondary voltages (measured at all the electrodes) and the computed secondary source current density. A kernel matrix relating the secondary observed voltages data to the source current density model is computed once (using the electrical conductivity distribution), and then used throughout the inversion process. This recovered source current density model is in turn used to estimate the time-dependent chargeability (normalized voltages) in each cell of the domain of interest. Assuming a Cole-Cole model for simplicity, we can reconstruct the 3-D distributions of the relaxation time τ and the Cole-Cole exponent c by fitting the intrinsic chargeability decay curve to a Cole-Cole relaxation model for each cell. Two simple cases are studied in details to explain this new approach. In the first case, we estimate the Cole-Cole parameters as well as the source current density field from a synthetic TDIP data set. Our approach is successfully able to reveal the presence of the anomaly and to invert its Cole

  9. Stopping of deuterium in warm dense deuterium from Ehrenfest time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Magyar, R.J.; Shulenburger, L.; Baczewski, A.D. [Sandia National Laboratories - Multi-scale Physics 1444 MS 1322, Albuquerque, NM (United States)

    2016-06-15

    In these proceedings, we show that time-dependent density functional theory is capable of stopping calculations at the extreme conditions of temperature and pressure seen in warm dense matter. The accuracy of the stopping curves tends to be up to about 20% lower than empirical models that are in use. However, TDDFT calculations are free from fitting parameters and assumptions about the model form of the dielectric function. This work allows the simulation of ion stopping in many materials that are difficult to study experimentally. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Beyond Rating Curves: Time Series Models for in-Stream Turbidity Prediction

    Science.gov (United States)

    Wang, L.; Mukundan, R.; Zion, M.; Pierson, D. C.

    2012-12-01

    The New York City Department of Environmental Protection (DEP) manages New York City's water supply, which is comprised of over 20 reservoirs and supplies over 1 billion gallons of water per day to more than 9 million customers. DEP's "West of Hudson" reservoirs located in the Catskill Mountains are unfiltered per a renewable filtration avoidance determination granted by the EPA. While water quality is usually pristine, high volume storm events occasionally cause the reservoirs to become highly turbid. A logical strategy for turbidity control is to temporarily remove the turbid reservoirs from service. While effective in limiting delivery of turbid water and reducing the need for in-reservoir alum flocculation, this strategy runs the risk of negatively impacting water supply reliability. Thus, it is advantageous for DEP to understand how long a particular turbidity event will affect their system. In order to understand the duration, intensity and total load of a turbidity event, predictions of future in-stream turbidity values are important. Traditionally, turbidity predictions have been carried out by applying streamflow observations/forecasts to a flow-turbidity rating curve. However, predictions from rating curves are often inaccurate due to inter- and intra-event variability in flow-turbidity relationships. Predictions can be improved by applying an autoregressive moving average (ARMA) time series model in combination with a traditional rating curve. Since 2003, DEP and the Upstate Freshwater Institute have compiled a relatively consistent set of 15-minute turbidity observations at various locations on Esopus Creek above Ashokan Reservoir. Using daily averages of this data and streamflow observations at nearby USGS gauges, flow-turbidity rating curves were developed via linear regression. Time series analysis revealed that the linear regression residuals may be represented using an ARMA(1,2) process. Based on this information, flow-turbidity regressions with

  11. Development of a Portable Training Tool for Simulating Visceral Angiographic Procedures for Beginners

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Osuga, Keigo; Yoshimatsu, Rika; Matsumoto, Tomohiro; Miura, Hiroshi; Terayama, Koshi; Anai, Hiroshi; Takahashi, Masahide; Hasebe, Terumitsu; Nishimura, Tsunehiko

    2009-01-01

    The purpose of this study was to evaluate the usefulness of a tool that we developed to simulate performance of visceral angiography to train beginners in the field of splanchnic angiography. Seven residents and two fellows who were rotating within the Division of Interventional Radiology at our institution between June and August 2008 participated in the evaluation of this tool. They had no experience in performing visceral angiography as an operator. Time for selection of arterial branches arising from the celiac axis on the model was measured before and after training. After such training, the participants performed actual visceral angiography as an operator with instructors beside them. Success of the trainees in selecting visceral arterial branches was evaluated in these real-life cases. In the first test using the model, seven of nine trainees (77.8%) succeeded in selecting all required arteries, while the remaining two failed to select all required arteries. After training using the model, all trainees succeeded in selecting all required arteries just before the actual angiographic study. In the actual angiography, the catheter was successfully inserted from the femoral artery and advanced to the superior mesenteric, celiac, splenic, common hepatic, gastroduodenal, and right and left hepatic arteries by all trainees with only two exceptions. In conclusion, this tool is helpful for training beginners in visceral angiographic procedures.

  12. Curve fitting of the corporate recovery rates: the comparison of Beta distribution estimation and kernel density estimation.

    Science.gov (United States)

    Chen, Rongda; Wang, Ze

    2013-01-01

    Recovery rate is essential to the estimation of the portfolio's loss and economic capital. Neglecting the randomness of the distribution of recovery rate may underestimate the risk. The study introduces two kinds of models of distribution, Beta distribution estimation and kernel density distribution estimation, to simulate the distribution of recovery rates of corporate loans and bonds. As is known, models based on Beta distribution are common in daily usage, such as CreditMetrics by J.P. Morgan, Portfolio Manager by KMV and Losscalc by Moody's. However, it has a fatal defect that it can't fit the bimodal or multimodal distributions such as recovery rates of corporate loans and bonds as Moody's new data show. In order to overcome this flaw, the kernel density estimation is introduced and we compare the simulation results by histogram, Beta distribution estimation and kernel density estimation to reach the conclusion that the Gaussian kernel density distribution really better imitates the distribution of the bimodal or multimodal data samples of corporate loans and bonds. Finally, a Chi-square test of the Gaussian kernel density estimation proves that it can fit the curve of recovery rates of loans and bonds. So using the kernel density distribution to precisely delineate the bimodal recovery rates of bonds is optimal in credit risk management.

  13. TELECOMMUNICATIONS INFRASTRUCTURE AND GDP /JIPP CURVE/

    Directory of Open Access Journals (Sweden)

    Mariana Kaneva

    2016-07-01

    Full Text Available The relationship between telecommunications infrastructure and economic activity is under discussion in many scientific papers. Most of the authors use for research and analysis the Jipp curve. A lot of doubts about the correctness of the Jipp curve appear in terms of applying econometric models. The aim of this study is a review of the Jipp curve, refining the possibility of its application in modern conditions. The methodology used in the study is based on dynamic econometric models, including tests for nonstationarity and tests for causality. The focus of this study is directed to methodological problems in measuring the local density types of telecommunication networks. This study offers a specific methodology for assessing the Jipp law, through VAR-approach and Granger causality tests. It is proved that mechanical substitution of momentary aggregated variables (such as the number of subscribers of a telecommunication network at the end of the year and periodically aggregated variables (such as GDP per capita in the Jipp�s curve is methodologically wrong. Researchers have to reconsider the relationship set in the Jipp�s curve by including additional variables that characterize the Telecommunications sector and the economic activity in a particular country within a specified time period. GDP per capita should not be regarded as a single factor for the local density of telecommunications infrastructure. New econometric models studying the relationship between the investments in telecommunications infrastructure and economic development may be not only linear regression models, but also other econometric models. New econometric models should be proposed after testing and validating with sound economic theory and econometric methodology.

  14. Utility of the whole-kidney and parenchymal time-activity curves for a prediction of diuretic response

    International Nuclear Information System (INIS)

    Samal, M.; Mostbeck, A.; Bergmann, H.; Nimmon, C.C.; Staudenherz, A.; Dudczak, R.

    2002-01-01

    Full text: In a retrospective study, MAG3 dynamic renal data (90 kidneys in 57 children) have been analyzed with the aim to test a prediction of diuretic response. Whole-kidney (WK) and parenchymal (PA) curves were extracted from 20 min pre-diuretic phase using standard and fuzzy ROIs. Peak time (PT), half time (HT), ratio of the curve value in 20th min to the curve maximum (RM), mean transit time (TT), and output efficiency (OE) were calculated for each curve. With PA curves, also the transit time index (PI) was calculated. The curve parameters were compared with the maximum elimination rate of urine after diuretic (EM) using paired correlation and Fisher's linear discriminate function. The highest correlation was found between ln EM and OE-PA (0.61), RM-PA (-0.58), TT-PA (-0.57), and PI (-0.57). Best diagnostic accuracy in prediction of EM ≤ 7 % (a sign of obstruction) was obtained with OE-PA (87 %), PI (87 %), and both PT-PA and RM-PA (83 %). Parameters of WK curves had higher sensitivity, those of PA curves higher specificity. Most parameters had a high predictive value of negative result (NPV > 90 %) but low predictive value of positive result (PPV < 50 %). Best discrimination of low EM was obtained with a combination of both WK and PA parameters (diagnostic accuracy of 90 %). Using PA curves in kidneys with late PT-WK made possible to increase the diagnostic accuracy from 70 - 80 % (with WK parameters only) to 95 %. Our results demonstrate that PA curves carry additional clinical information and may help to predict and Interpret a diuretic response especially in kidneys with late peak of the WK curves. (author)

  15. Diagnostic accuracy of unenhanced, contrast-enhanced perfusion and angiographic MRI sequences for pulmonary embolism diagnosis: results of independent sequence readings

    Energy Technology Data Exchange (ETDEWEB)

    Revel, Marie Pierre [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Hotel-Dieu, Service de Radiologie, Paris (France); Sanchez, Olivier; Meyer, Guy [Hopital Europeen Georges Pompidou, APHP, Respiratory and intensive care and, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM Unite 765, Paris (France); Lefort, Catherine; Couchon, Sophie; Hernigou, Anne; Frija, Guy [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Niarra, Ralph [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Chatellier, Gilles [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM CIC-EC E4, Paris (France)

    2013-09-15

    To independently evaluate unenhanced, contrast-enhanced perfusion and angiographic MR sequences for pulmonary embolism (PE) diagnosis. Prospective investigation, including 274 patients who underwent perfusion, unenhanced 2D steady-state-free-precession (SSFP) and contrast-enhanced 3D angiographic MR sequences on a 1.5-T unit, in addition to CTA (CT angiography). Two independent readers evaluated each sequence independently in random order. Sensitivity, specificity, predictive values and inter-reader agreement were calculated for each sequence, excluding sequences judged inconclusive. Sensitivity was also calculated according to PE location. Contrast-enhanced angiographic sequences showed the highest sensitivity (82.9 and 89.7 %, reader 1 and reader 2, respectively), specificity (98.5 and 100 %) and agreement (kappa value 0.77). Unenhanced angiographic sequences, although less sensitive overall (68.7 and 76.4 %), were sensitive for the detection of proximal PE (92.7 and 100 %) and showed high specificity (96.1 and 99.1 %) and good agreement (kappa value 0.62). Perfusion sequences showed lower sensitivity (75.0 and 79.3 %), specificity (84.8 and 89.7 %) and agreement (kappa value 0.51), and a negative predictive value of 84.8 % at best. Compared with contrast-enhanced angiographic sequences, unenhanced sequences demonstrate lower sensitivity, except for proximal PE, but high specificity and agreement. The negative predictive value of perfusion sequences was insufficient to safely rule out PE. (orig.)

  16. Local differential geometry of null curves in conformally flat space-time

    International Nuclear Information System (INIS)

    Urbantke, H.

    1989-01-01

    The conformally invariant differential geometry of null curves in conformally flat space-times is given, using the six-vector formalism which has generalizations to higher dimensions. This is then paralleled by a twistor description, with a twofold merit: firstly, sometimes the description is easier in twistor terms, sometimes in six-vector terms, which leads to a mutual enlightenment of both; and secondly, the case of null curves in timelike pseudospheres or 2+1 Minkowski space we were only able to treat twistorially, making use of an invariant differential found by Fubini and Cech. The result is the expected one: apart from stated exceptional cases there is a conformally invariant parameter and two conformally invariant curvatures which, when specified in terms of this parameter, serve to characterize the curve up to conformal transformations. 12 refs. (Author)

  17. The value of regional wall motion abnormalities on 99Tcm-MIBI gated cardiac SPECT in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Zhu Tiebing; Wang Liansheng; Yang Zhijian; Feng Jianlin; Li Jianhua; Chen Jianwei; Chang Guojun

    2004-01-01

    Objective: To determine the magnitude of angiographic stenoses of coronary artery in reversible regional wall motion abnormalities (RWMA) present in exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) gated SPECT myocardial perfusion imaging (MPI). Methods: One hundred and sixteen patients undergoing coronary angiography two weeks before and after the exercise stress 99 Tc m -MIBI gated SPECT MPI. Images were acquired 15 to 20 min after stress. A five grades and twenty segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 65%, with a specificity of 97%. Reversible RWMA has a high positive predictive value (98%) for stratification between severe angiographic stenoses of 75% and non-severe stenoses (less than 75%). Multivariate analysis showed that the post-stress wall motion (SSSWM), exercise wall motion differentiation value (SDSWM) and summed stress score (SSS) were the independent risk factor of coronary artery jeopardy score. Conclusions: Reversible RWMA, as shown by exercise stress 99 Tc m -MIBI gated SPECT MPI, is a significant predictor of angiographic disease with very high specificity and positive predictive values. Exercise reversible RWMA can rise the assessment value of angiographic severity in MPI

  18. Wigner functions and density matrices in curved spaces as computational tools

    International Nuclear Information System (INIS)

    Habib, S.; Kandrup, H.E.

    1989-01-01

    This paper contrasts two alternative approaches to statistical quantum field theory in curved spacetimes, namely (1) a canonical Hamiltonian approach, in which the basic object is a density matrix ρ characterizing the noncovariant, but globally defined, modes of the field; and (2) a Wigner function approach, in which the basic object is a Wigner function f defined quasilocally from the Hadamard, or correlation, function G 1 (x 1 , x 2 ). The key object is to isolate on the conceptual biases underlying each of these approaches and then to assess their utility and limitations in effecting concerete calculations. The following questions are therefore addressed and largely answered. What sort of spacetimes (e.g., de Sitter or Friedmann-Robertson-Walker) are comparatively eas to consider? What sorts of objects (e.g., average fields or renormalized stress energies) are easy to compute approximately? What, if anything, can be computed exactly? What approximations are intrinsic to each approach or convenient as computational tools? What sorts of ''field entropies'' are natural to define? copyright 1989 Academic Press, Inc

  19. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  20. Curve fitting of the corporate recovery rates: the comparison of Beta distribution estimation and kernel density estimation.

    Directory of Open Access Journals (Sweden)

    Rongda Chen

    Full Text Available Recovery rate is essential to the estimation of the portfolio's loss and economic capital. Neglecting the randomness of the distribution of recovery rate may underestimate the risk. The study introduces two kinds of models of distribution, Beta distribution estimation and kernel density distribution estimation, to simulate the distribution of recovery rates of corporate loans and bonds. As is known, models based on Beta distribution are common in daily usage, such as CreditMetrics by J.P. Morgan, Portfolio Manager by KMV and Losscalc by Moody's. However, it has a fatal defect that it can't fit the bimodal or multimodal distributions such as recovery rates of corporate loans and bonds as Moody's new data show. In order to overcome this flaw, the kernel density estimation is introduced and we compare the simulation results by histogram, Beta distribution estimation and kernel density estimation to reach the conclusion that the Gaussian kernel density distribution really better imitates the distribution of the bimodal or multimodal data samples of corporate loans and bonds. Finally, a Chi-square test of the Gaussian kernel density estimation proves that it can fit the curve of recovery rates of loans and bonds. So using the kernel density distribution to precisely delineate the bimodal recovery rates of bonds is optimal in credit risk management.

  1. Curve Fitting of the Corporate Recovery Rates: The Comparison of Beta Distribution Estimation and Kernel Density Estimation

    Science.gov (United States)

    Chen, Rongda; Wang, Ze

    2013-01-01

    Recovery rate is essential to the estimation of the portfolio’s loss and economic capital. Neglecting the randomness of the distribution of recovery rate may underestimate the risk. The study introduces two kinds of models of distribution, Beta distribution estimation and kernel density distribution estimation, to simulate the distribution of recovery rates of corporate loans and bonds. As is known, models based on Beta distribution are common in daily usage, such as CreditMetrics by J.P. Morgan, Portfolio Manager by KMV and Losscalc by Moody’s. However, it has a fatal defect that it can’t fit the bimodal or multimodal distributions such as recovery rates of corporate loans and bonds as Moody’s new data show. In order to overcome this flaw, the kernel density estimation is introduced and we compare the simulation results by histogram, Beta distribution estimation and kernel density estimation to reach the conclusion that the Gaussian kernel density distribution really better imitates the distribution of the bimodal or multimodal data samples of corporate loans and bonds. Finally, a Chi-square test of the Gaussian kernel density estimation proves that it can fit the curve of recovery rates of loans and bonds. So using the kernel density distribution to precisely delineate the bimodal recovery rates of bonds is optimal in credit risk management. PMID:23874558

  2. Analysis of contrast-enhanced ultrasonography using time-intensity curves in prostatic hyperplasia and prostate cancer

    International Nuclear Information System (INIS)

    Fang Junchu; Chen Ming; Sun Huifen

    2008-01-01

    Objective: To study the characters of time-intensity curve of contrast-enhanced ultrasonography in benign prostate hyperplasia (BPH) and prostate cancer. Methods: 2.4 ml Sono Vue were injected as a bolus in 40 patients, 23 patients with BPH and 17 with prostate cancer. High perfusion area in both inner and outer gland were measured with time-intensity curves. Results: It was proved by the time-intensity curves that, in BPH cases, the outer prostate gland presented with mild enhancedment and slow wash-off, while the inner gland presented with moderate enhancedment and fast wash-off. Otherwise, both the inner and outer gland in prostate cancer cases presented with high-intensitive enhancedment and slow wash-off. There was marked difference statistical significance on the up slop, average intensity and area under the time-intensity curves in 90 s and 150 s between the cases of BPH and prostate cancer (P<0.05, P<0.01). Conclusion: Quantitative analysis of high perfusion area in both inner and outer glands is helpful for diagnosing BPH and prostate cancer. (authors)

  3. Clinical-pathological-angiographic correlations following transluminal atherectomy

    International Nuclear Information System (INIS)

    Althaus, S.J.; Maynar, M.; Reyes, R.; Pulido-Duque, J.M.; Casal, G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1989-01-01

    Following percutaneous atherectomy, arterial and catheter diameter relationships were correlated with angiographic and ankle-arm index results. There was a greater amount of tissue removed, improved luminal reconstitution, and ankle-arm index in lesions where the catheter and arterial diameters were equal or within 0.5 mm. Excluding lesions requiring angioplasty, 77% of our lesions had less than 30% residual stenosis; including lesions requiring concomitant angioplasty, the initial overall patency was 93%, with a 1-year patency rate of 92.5%. This study indicates that adequate matching of the atherectomy catheter diameter to the arterial diameter is necessary to optimize tissue removal and clinical results

  4. Estimation of error on the cross-correlation, phase and time lag between evenly sampled light curves

    Science.gov (United States)

    Misra, R.; Bora, A.; Dewangan, G.

    2018-04-01

    Temporal analysis of radiation from Astrophysical sources like Active Galactic Nuclei, X-ray Binaries and Gamma-ray bursts provides information on the geometry and sizes of the emitting regions. Establishing that two light-curves in different energy bands are correlated, and measuring the phase and time-lag between them is an important and frequently used temporal diagnostic. Generally the estimates are done by dividing the light-curves into large number of adjacent intervals to find the variance or by using numerically expensive simulations. In this work we have presented alternative expressions for estimate of the errors on the cross-correlation, phase and time-lag between two shorter light-curves when they cannot be divided into segments. Thus the estimates presented here allow for analysis of light-curves with relatively small number of points, as well as to obtain information on the longest time-scales available. The expressions have been tested using 200 light curves simulated from both white and 1 / f stochastic processes with measurement errors. We also present an application to the XMM-Newton light-curves of the Active Galactic Nucleus, Akn 564. The example shows that the estimates presented here allow for analysis of light-curves with relatively small (∼ 1000) number of points.

  5. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig

  6. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig.

  7. Mass Formulae for Broken Supersymmetry in Curved Space-Time

    CERN Document Server

    Ferrara, Sergio

    2016-01-01

    We derive the mass formulae for ${\\cal N}=1$, $D=4$ matter-coupled Supergravity for broken (and unbroken) Supersymmetry in curved space-time. These formulae are applicable to de Sitter configurations as is the case for inflation. For unbroken Supersymmetry in anti-de Sitter (AdS) one gets the mass relations modified by the AdS curvature. We compute the mass relations both for the potential and its derivative non-vanishing.

  8. Comparative quantitative angiographic analysis of directional coronary atherectomy and balloon coronary angioplasty

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); K.J. Beatt (Kevin); B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1991-01-01

    markdownabstract__Abstract__ An attempt to assess the “utility” of directional atherectomy was made using a new quantitative angiographic index. This index can be subdivided into an initial gain component and a restenosis component. The initial gain index is the ratio between the gain in diameter

  9. Covariant Density Functionals: time-odd channel investigated

    International Nuclear Information System (INIS)

    Afanasjev, A. V.; Abusara, H.

    2009-01-01

    The description of exotic nuclear systems and phenomena requires a detailed understanding of all channels of density functional theories. The role of time-odd mean fields, their evidence in experiment, and an accurate description of these fields are subject of current interest. Recent studies advanced the understanding of these fields in energy density functional theories based on the Skyrme force [1,2]. Time-odd mean fields are related to nuclear magnetism in covariant density functional (CDF) theories [3]. They arise from space-like components of vector mesons and Lorentz invariance requires that their coupling strengths are identical to that of time-like components. There were only few limited efforts to understand the role of time-odd mean fields in covariant density functional theory [4,5]. For example, the microscopic role of nuclear magnetism and its impact on rotational properties of nuclei has been studied in Ref. [5]. It is known that time-odd mean fields modify the angular momentum content of the single-particle orbitals and thus the moments of inertia, effective alignments, alignment gains at the band crossings and other physical observables. We aim on more detailed and systematic understanding of the role of time-odd mean fields in covariant density functional theory. This investigation covers both rotating and non-rotating systems. It is shown that contrary to the Skyrme energy density functionals time-odd mean fields of CDF theory always provide additional binding in the systems with broken time-reversal symmetry (rotating nuclei, odd mass nuclei). This additional binding increases with spin and has its maximum exactly at the terminating state [6], where it can reach several MeV. The impact of time-odd mean fields on the properties of rotating systems has been studied in a systematic way (as a function of particle number and deformation) across the nuclear chart [7]. In addition, this contribution extends these studies to non-rotating systems such as

  10. Hemodynamic disturbances in cerebral ischemia; Correlation between positron emission tomographic and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Tenjin, Hiroshi; Ueda, Satoshi; Mizukawa, Norihiko; Imahori, Yoshio; Hino, Akihiko; Ohmori, Yoshio [Kyoto Prefectural Univ. of Medicine (Japan); Nakahashi, Hisamitsu

    1993-04-01

    Proper treatment of ischemic stroke requires better understanding of cerebral hemodynamic changes. The hemodynamic changes associated with ischemia were measured using positron emission tomography and related to angiographic findings in the subacute and chronic stages of 17 ischemia patients who showed symptoms of main trunk stenosis of the internal carotid artery system. The hemodynamic factors, cerebral blood flow, cerebral blood volume, cerebral metabolic rate for oxygen, oxygen extraction fraction, and flow/volume ratio, were measured in regions of interest determined from the angiographic stenosis (over 50%) and compared in each stage. The cerebral blood flow and flow/volume ratio in the territory downstream of the main trunk stenosis and cerebral metabolic rate for oxygen in the whole cortex were decreased in the subacute stage. In the chronic stage, cerebral blood flow and flow/volume ratio decreased mainly in borderzone areas. (author).

  11. On Fermat's principle for causal curves in time oriented Finsler spacetimes

    Science.gov (United States)

    Gallego Torromé, Ricardo; Piccione, Paolo; Vitório, Henrique

    2012-12-01

    In this work, a version of Fermat's principle for causal curves with the same energy in time orientable Finsler spacetimes is proved. We calculate the second variation of the time arrival functional along a geodesic in terms of the index form associated with the Finsler spacetime Lagrangian. Then the character of the critical points of the time arrival functional is investigated and a Morse index theorem in the context of Finsler spacetime is presented.

  12. Risk factors and short-term outcome in patients with angiographically negative subarachnoid hemorrhage

    DEFF Research Database (Denmark)

    Dalbjerg, Sara Maria; Larsen, Carl Christian; Romner, Bertil

    2013-01-01

    The objective of this study was to identify prognostic factors for clinical outcome in patients with non-traumatic, angiographically negative subarachnoid hemorrhage. Furthermore, the aim was to investigate if patients on anticoagulant therapy may have a more unfavorable outcome than patients...

  13. Angiographic evaluation of the effect of intra-arterial milrinone therapy in patients with vasospasm from aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Shankar, Jai Jai Shiva; dos Santos, Marlise P; Deus-Silva, Leonardo; Lum, Cheemun

    2011-02-01

    Several methods have been used to treat cerebral vasospasm, which is a major cause of morbidity and mortality in patients with aneurysmal subarachnoid hemorrhage (SAH). Here, we examined the effectiveness and safety of intra-arterial injection of milrinone for the treatment of vasospasm. Consecutive patients with angiographically confirmed vasospasm received intra-arterial milrinone between January 2006 and December 2007. The improvement in diameter of vessel (in millimeters) following treatment was assessed by paired t test for statistical significance. The angiographic improvement of supraclinoid internal carotid artery, M1 segment of middle cerebral artery, and A1 and A2 segment of anterior cerebral artery was compared with the modified Rankin score of the patients at discharge. A total of 15 milrinone treatments were performed in 14 patients (11 females and 3 males) with mean age of 52.7 years (31-68 years). There was significant angiographic improvement after milrinone therapy (p milrinone was a safe and effective treatment of cerebral vasospasm following aneurysmal SAH.

  14. Nonparametric volatility density estimation for discrete time models

    NARCIS (Netherlands)

    Es, van Bert; Spreij, P.J.C.; Zanten, van J.H.

    2005-01-01

    We consider discrete time models for asset prices with a stationary volatility process. We aim at estimating the multivariate density of this process at a set of consecutive time instants. A Fourier-type deconvolution kernel density estimator based on the logarithm of the squared process is proposed

  15. Obtaining the conversion curve of CT numbers to electron density from the effective energy of the CT using the dummy SEFM

    International Nuclear Information System (INIS)

    Martin-Viera Cueto, J. A.; Garcia Pareja, S.; Benitez Villegas, E. M.; Moreno Saiz, E. M.; Bodineau Gil, C.; Caudepon Moreno, F.

    2011-01-01

    The objective of this work is to obtain the conversion curve of Hounsfield units (A) versus electron densities using a mannequin with different tissue equivalent materials. This provides for the effective energy beam CT and is used to characterize the linear coefficients of absorption of different materials that comprise the dummy.

  16. Differential Clinical Outcomes Between Angiographic Complete Versus Incomplete Coronary Revascularization, According to the Presence of Chronic Kidney Disease in the Drug-Eluting Stent Era.

    Science.gov (United States)

    Kim, Jihoon; Lee, Joo Myung; Choi, Ki Hong; Rhee, Tae-Min; Hwang, Doyeon; Park, Jonghanne; Ahn, Chul; Park, Taek Kyu; Yang, Jeong Hoon; Song, Young Bin; Choi, Jin-Ho; Hahn, Joo-Yong; Choi, Seung-Hyuk; Gwon, Hyeon-Cheol

    2018-02-15

    There are limited data regarding the prognostic impact of angiographic complete revascularization (CR) in patients with chronic kidney disease (CKD). We sought to investigate the differential prognostic impact of angiographic CR over incomplete revascularization (IR), according to the presence of CKD in the drug-eluting stent era. Between 2003 and 2011 at Samsung Medical Center, consecutive patients with multivessel disease were stratified by the presence of CKD (estimated glomerular filtration rate <60 mL/min per 1.73 m 2 ) and classified according to angiographic CR (residual SYNTAX score=0) or IR. Clinical outcomes were compared between angiographic CR and IR, stratified by the presence of CKD. Primary outcome was patient-oriented composite outcomes (POCO, a composite of all-cause death, myocardial infarction, any revascularization) at 3 years. Inverse probability weighting was performed between the CR and IR groups. A total of 3224 patients were eligible for analysis: 2295 without CKD; 929 with CKD. Among non-CKD patients, angiographic CR showed a significantly lower risk of POCO than IR (17.2% versus 21.7%, adjusted hazard ratio 0.76, 95% confidence interval, 0.62-0.95, P =0.014), mainly driven by a significantly lower risk of any revascularization. Among CKD patients, however, angiographic CR was associated with a significantly higher risk of POCO than IR (37.7% versus 28.4%, adjusted hazard ratio 1.42, 95% confidence interval, 1.08%-1.85%, P =0.011), mainly driven by a significantly higher risk of nonfatal target vessel myocardial infarction. Angiographic CR was associated with reduced risk of POCO than IR in patients without CKD; however, it was associated with a significantly higher risk of POCO and nonfatal myocardial infarction in CKD patients. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  17. The optimization of scan timing for contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Lee, Jong Min; Chang, Yong Min; Ryeom, Hun Kyu; Lee, Sang Kwon; Kim, Yong Sun; Kang, Duk Sik; Tirman, Philip J.

    2000-01-01

    To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the Time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method

  18. Quantum electrodynamics in curved space-time

    International Nuclear Information System (INIS)

    Buchbinder, I.L.; Gitman, D.M.; Fradkin, E.S.

    1981-01-01

    The lagrangian of quantum electrodynamics in curved space-time is constructed and the interaction picture taking into account the external gravitational field exactly is introduced. The transform from the Heisenberg picture to the interaction picture is carried out in a manifestly covariant way. The properties of free spinor and electromagnetic quantum fields are discussed and conditions under which initial and final creation and annihilation operators are connected by unitarity transformation are indicated. The derivation of Feynman's rules for quantum processes are calculated on the base of generalized normal product of operators. The way of reduction formula derivations is indicated and the suitable Green's functions are introduced. A generating functional for this Green's function is defined and the system of functional equations for them is obtained. The representation of different generating funcationals by means of functional integrals is introduced. Some consequences of S-matrix unitary condition are considered which leads to the generalization of the optic theorem

  19. Density measurements of microsecond-conduction-time POS plasmas

    International Nuclear Information System (INIS)

    Hinshelwood, D.; Goodrich, P.J.; Weber, B.V.; Commisso, R.J.; Grossmann, J.M.; Kellogg, J.C.

    1993-01-01

    Measurements of the electron density in a coaxial microsecond conduction time plasma opening switch during switch operation are described. Current conduction is observed to cause a radial redistribution of the switch plasma. A local reduction in axial line density of more than an order of magnitude occurs by the time opening begins. This reduction, and the scaling of conduction current with plasma density, indicate that current conduction in this experiment is limited by hydrodynamic effects. It is hypothesized that the density reduction allows the switch to open by an erosion mechanism. Initial numerical modeling efforts have reproduced the principal observed results. A model that predicts accurately the conduction current is presented

  20. Decay of autoionizing states in time-dependent density functional and reduced density matrix functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, Varun; Brics, Martins; Bauer, Dieter [Institut fuer Physik, Universitaet Rostock, 18051 Rostock (Germany)

    2013-07-01

    Autoionizing states are inaccessible to time-dependent density functional theory (TDDFT) using known, adiabatic Kohn-Sham (KS) potentials. We determine the exact KS potential for a numerically exactly solvable model Helium atom interacting with a laser field that is populating an autoionizing state. The exact single-particle density of the population in the autoionizing state corresponds to that of the energetically lowest quasi-stationary state in the exact KS potential. We describe how this exact potential controls the decay by a barrier whose height and width allows for the density to tunnel out and decay with the same rate as in the ab initio time-dependent Schroedinger calculation. However, devising a useful exchange-correlation potential that is capable of governing such a scenario in general and in more complex systems is hopeless. As an improvement over TDDFT, time-dependent reduced density matrix functional theory has been proposed. We are able to obtain for the above described autoionization process the exact time-dependent natural orbitals (i.e., the eigenfunctions of the exact, time-dependent one-body reduced density matrix) and study the potentials that appear in the equations of motion for the natural orbitals and the structure of the two-body density matrix expanded in them.

  1. Plasma density control in real-time on the COMPASS tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Janky, F., E-mail: filip.janky.work@gmail.com [Institute of Plasma Physics AS CR, v.v.i., Association EURATOM/IPP.CR, Za Slovankou 3, 182 00 Praha 8 (Czech Republic); Department of Surface and Plasma Science, Faculty of Mathematics and Physics, Charles University in Prague, V Holešovičkách 2, 180 00 Praha 8 (Czech Republic); Hron, M. [Institute of Plasma Physics AS CR, v.v.i., Association EURATOM/IPP.CR, Za Slovankou 3, 182 00 Praha 8 (Czech Republic); Havlicek, J. [Institute of Plasma Physics AS CR, v.v.i., Association EURATOM/IPP.CR, Za Slovankou 3, 182 00 Praha 8 (Czech Republic); Department of Surface and Plasma Science, Faculty of Mathematics and Physics, Charles University in Prague, V Holešovičkách 2, 180 00 Praha 8 (Czech Republic); Varavin, M.; Zacek, F.; Seidl, J.; Panek, R. [Institute of Plasma Physics AS CR, v.v.i., Association EURATOM/IPP.CR, Za Slovankou 3, 182 00 Praha 8 (Czech Republic)

    2015-10-15

    Highlights: • We fitted length of the chord of the interferometry crossing plasma in the different plasma scenarios. • We add correction to the actual length of the chord of the interferometry according to plasma shape and position in real-time code. • We used this correction to control plasma density in real-time. - Abstract: The electron density on COMPASS is measured using 2 mm microwave interferometer. Interferometer signal is used as an input for the feedback control loop, running under the MARTe real-time framework. Two different threads are used to calculate (fast 50 μs thread) and to control (slow 500 μs thread) the electron density. The interferometer measures a line averaged density along a measurement chord. This paper describes an approach to control the line-averaged electron density in a real-time loop, using a correction to the real plasma shape, the plasma position, and non-linear effects of the electron density measurement at high densities. Newly developed real-time electron density control give COMPASS the chance to control the electron density more accurately which is essential for parametric scans for diagnosticians, for physics experiments and also for achieving plasma scenarios with H-mode.

  2. Using Growth Curves To Determine the Timing of the Booster Sessions.

    Science.gov (United States)

    Hennessy, Michael; Bolan, Gail A.; Hoxworth, Tamara; Iatesta, Michael; Rhodes, Fen; Zenilman, Jonathan M.

    1999-01-01

    Demonstrates an application of a method for using growth curves to determine the timing of booster sessions to reinforce the cognitive messages or behavior changes of interventions. Uses data from a multisite randomized experiment that compared three counseling and testing methods for preventing sexual disease transmission. Presents…

  3. Multicomponent density-functional theory for time-dependent systems

    NARCIS (Netherlands)

    Butriy, O.; Ebadi, H.; de Boeij, P. L.; van Leeuwen, R.; Gross, E. K. U.

    2007-01-01

    We derive the basic formalism of density functional theory for time-dependent electron-nuclear systems. The basic variables of this theory are the electron density in body-fixed frame coordinates and the diagonal of the nuclear N-body density matrix. The body-fixed frame transformation is carried

  4. Mass formulae for broken supersymmetry in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Ferrara, Sergio [Theoretical Physics Department, CERN, Geneva (Switzerland); INFN - Laboratori Nazionali di Frascati, Frascati (Italy); Department of Physics and Astronomy, U.C.L.A, Los Angeles, CA (United States); Proeyen, Antoine van [KU Leuven, Institute for Theoretical Physics, Leuven (Belgium)

    2016-11-15

    We derive the mass formulae for N = 1, D = 4 matter-coupled Supergravity for broken (and unbroken) Supersymmetry in curved space-time. These formulae are applicable to De Sitter configurations as is the case for inflation. For unbroken Supersymmetry in anti-de Sitter (AdS) one gets the mass relations modified by the AdS curvature. We compute the mass relations both for the potential and its derivative non-vanishing. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Massless fields in curved space-time: The conformal formalism

    International Nuclear Information System (INIS)

    Castagnino, M.A.; Sztrajman, J.B.

    1986-01-01

    A conformally invariant theory for massless quantum fields in curved space-time is formulated. We analyze the cases of spin-0, - 1/2 , and -1. The theory is developed in the important case of an ''expanding universe,'' generalizing the particle model of ''conformal transplantation'' known for spin-0 to spins- 1/2 and -1. For the spin-1 case two methods introducing new conformally invariant gauge conditions are stated, and a problem of inconsistency that was stated for spin-1 is overcome

  6. Extension of the master sintering curve for constant heating rate modeling

    Science.gov (United States)

    McCoy, Tammy Michelle

    The purpose of this work is to extend the functionality of the Master Sintering Curve (MSC) such that it can be used as a practical tool for predicting sintering schemes that combine both a constant heating rate and an isothermal hold. Rather than just being able to predict a final density for the object of interest, the extension to the MSC will actually be able to model a sintering run from start to finish. Because the Johnson model does not incorporate this capability, the work presented is an extension of what has already been shown in literature to be a valuable resource in many sintering situations. A predicted sintering curve that incorporates a combination of constant heating rate and an isothermal hold is more indicative of what is found in real-life sintering operations. This research offers the possibility of predicting the sintering schedule for a material, thereby having advanced information about the extent of sintering, the time schedule for sintering, and the sintering temperature with a high degree of accuracy and repeatability. The research conducted in this thesis focuses on the development of a working model for predicting the sintering schedules of several stabilized zirconia powders having the compositions YSZ (HSY8), 10Sc1CeSZ, 10Sc1YSZ, and 11ScSZ1A. The compositions of the four powders are first verified using x-ray diffraction (XRD) and the particle size and surface area are verified using a particle size analyzer and BET analysis, respectively. The sintering studies were conducted on powder compacts using a double pushrod dilatometer. Density measurements are obtained both geometrically and using the Archimedes method. Each of the four powders is pressed into ¼" diameter pellets using a manual press with no additives, such as a binder or lubricant. Using a double push-rod dilatometer, shrinkage data for the pellets is obtained over several different heating rates. The shrinkage data is then converted to reflect the change in relative

  7. The genus curve of the Abell clusters

    Science.gov (United States)

    Rhoads, James E.; Gott, J. Richard, III; Postman, Marc

    1994-01-01

    We study the topology of large-scale structure through a genus curve measurement of the recent Abell catalog redshift survey of Postman, Huchra, and Geller (1992). The structure is found to be spongelike near median density and to exhibit isolated superclusters and voids at high and low densities, respectively. The genus curve shows a slight shift toward 'meatball' topology, but remains consistent with the hypothesis of Gaussian random phase initial conditions. The amplitude of the genus curve corresponds to a power-law spectrum with index n = 0.21-0.47+0.43 on scales of 48/h Mpc or to a cold dark matter power spectrum with omega h = 0.36-0.17+0.46.

  8. The genus curve of the Abell clusters

    Science.gov (United States)

    Rhoads, James E.; Gott, J. Richard, III; Postman, Marc

    1994-01-01

    We study the topology of large-scale structure through a genus curve measurement of the recent Abell catalog redshift survey of Postman, Huchra, and Geller (1992). The structure is found to be spongelike near median density and to exhibit isolated superclusters and voids at high and low densities, respectively. The genus curve shows a slight shift toward 'meatball' topology, but remains consistent with the hypothesis of Gaussian random phase initial conditions. The amplitude of the genus curve corresponds to a power-law spectrum with index n = 0.21(sub -0.47 sup +0.43) on scales of 48/h Mpc or to a cold dark matter power spectrum with omega h = 0.36(sub -0.17 sup +0.46).

  9. Cerebellar hemangioblastomas with computed tomographic, angiographic, and positron-emission tomographic evaluations

    International Nuclear Information System (INIS)

    Kikuchi, Kenji; Sakamoto, Tetsuya; Kowada, Masayoshi; Tamakawa, Yoshiharu; Uemura, Kazuo.

    1986-01-01

    Ten patients with cerebellar hemangioblastomas were reviewed, and evaluations were made by computed tomography (CT), vertebral angiography, and positron-emission tomography (PET). Cerebellar hemangioblastomas were classified into three types on the basis of their CT appearances: Type I: a cystic tumor without a demonstrable mural nodule; Type II: a cystic tumor with a mural nodule, and Type III: a solid tumor without any cyst formation. All of the cystic tumors classified here as Types I and II were associated with a shift and deformity of the fourth ventricule and an enlarged lateral ventricle, and yet no low-density area in the adjacent cerebellar tissue indicating perifocal edema was demonstrated. By contrast, in the solid hemangioblastomas designated as Type III, finger-shaped, low-density areas were visualized around the enhancing mass lesion, extending to the white matter of the entire affected cerebellar hemisphere. The vertebral angiographic classification of cerebellar hemangioblastomas was also attempted as follows: Type I: an avascular tumor without a demonstrable mural nodule; Type II: an avascular tumor with a mural nodule, and Type III: a solid vascular tumor with enlarged feeding arteries and distinct draining veins. In Type II, a relatively small mural nodule was visualized, fed mostly by a single feeding artery, and the tumor stain was at its peak at the arterial phase. No draining vein was opacified in most cases. In contrast, solid tumors classified as Type III were demonstrated to be hypervascular tumors with a multiplicity of feeding arteries and draining veins. The vascular mass remained to be opacified through the venous phase with delayed blood circulation. PET was performed on a 31-year-old male with a solid hemangioblastoma. (J.P.N)

  10. Density fluctuations in the de Sitter universe

    International Nuclear Information System (INIS)

    Banerjee, N.; Mallik, S.

    1991-01-01

    The de Sitter space-time appears to be the most widely chosen manifold to study quantum field theories on curved space-time. The reason is, of course, its high symmetry and the related fact that the mode functions can be obtained exactly in terms of known functions. Thus the different problems of quantization on curved space-time, like the non-uniqueness of the vacuum, regularization and renormalization of the stress tensor, have all been studied extensively in this model. The other reason of interest in the de Sitter geometry is related to the inflationary scenario of the early universe. For a brief period, the energy density of the false (symmetric) vacuum may dominate the total energy density, giving rise to de Sitter space-time. The resulting inflation may solve a number of outstanding problems of cosmology and particle physics. The properties of a Higgs-type scalar field theory is of central importance in the investigation of such a scenario. In this paper, a scalar Higgs field theory in de Sitter space-time has been investigated using the real time formulation of Semenoff and Weiss. The authors calculate the two-point function at late times and use it to obtain a general expression for the amplitude of fluctuation in energy density on scales which come out of the de Sitter horizon

  11. Internal carotid arterial occlusion in computed tomography. Correlation of CT and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Harada, K.; Miura, T.; Nishikubo, Y.; Kawai, R.; Mitomo, M. (Osaka Univ. (Japan). Faculty of Medicine)

    1981-09-01

    The computed tomographic appearance of internal carotid arterial occlusion was reviewed in 33 patients. In 23 of them, who underwent 4-vessel study, the angiographic and CT findings were compared. Ten patients were disclosed to have watershed infarction by CT. Seven of them had watershed processes in the centrum semiovale which were considered to be terminal infarction. Patients who showed watershed infarction under CT revealed inadequate circle of Willis and well-developed cortical anastomosis under angiography. Unilaterally accentuated cerebral atrophy, which we have called asymmetrical atrophy in this paper, was noted in 10 patients. The findings of asymmetrical cerebral atrophy sometimes resemble the changes secondary to old infarction. However, the changes in the lateral ventricle caused by asymmetrical cerebral atrophy are somewhat different from those resulting from old infarction. The angiographic findings suggested that asymmetrical cerebral atrophy is, in addition to being associated with incomplete circle of Willis, also associated with local circulatory disturbances which further decrease the regional cerebral blood flow in the affected hemisphere.

  12. Angiographic differentiation of type of ventricular septal defects

    International Nuclear Information System (INIS)

    Cheon, Mal Soon; Park, Hee Young; Kim, Yang Sook

    1989-01-01

    Defects of the ventricular septum are the commonest type of congenital cardiac malformations. A classification with axial angiography of the subtypes of ventricular septal defects is proposed on the study of 126 patients with defects of the ventricular septum. The results were as follows: 1. The incidence of the ventricular septal defects was 39.6% of congenital heart malformation. 2. The sex distribution of cases were 70 males and 56 females, the age ranged from 13 months to 26 years. 3. Angiographic features seen by axial angiography were as follows: a. Perimembranous defects as seen on long axial view of left ventriculogram were in continuity wity aortic valve. The relation of the defect to the tricuspid valve allows distinction of the extension of the preimembranous defect toward inlet, trabecular, or infundibular zones. This relation was determined angiographically, using the course of the contrast medium from the left ventricle through the ventricular septal defect, opacifying the right ventricle. In inlet excavation, the shunted blood opacified the recess between septal leaflet of tricuspid valve and interventricular septum in early phase, in infundibular excavation, opacified the recess between anterior leaflet of tricuspid valve and anterior free wall of right ventricle and in trabecular excavation, the shunted blood traversed anterior portion of tricuspid valve ring, opacified trabecular portion of right ventricle. b. Muscular defects were separated from the semilunar and atrioventricular valves. c, Subarterial defects were related to both semilunar valves, and they were best demonstrated on the elongated right anterior oblique view of the left ventriculogram. d. Total infundibular defects were profiled in right anterior oblique 30 and long axial view, subaortic in location in both views

  13. Point splitting in a curved space-time background

    International Nuclear Information System (INIS)

    Liggatt, P.A.J.; Macfarlane, A.J.

    1979-01-01

    A prescription is given for point splitting in a curved space-time background which is a natural generalization of that familiar in quantum electrodynamics and Yang-Mills theory. It is applied (to establish its validity) to the verification of the gravitational anomaly in the divergence of a fermion axial current. Notable features of the prescription are that it defines a point-split current that can be differentiated straightforwardly, and that it involves a natural way of averaging (four-dimensionally) over the directions of point splitting. The method can extend directly from the spin-1/2 fermion case treated to other cases, e.g., to spin-3/2 Rarita-Schwinger fermions. (author)

  14. Watching excitons move: the time-dependent transition density matrix

    Science.gov (United States)

    Ullrich, Carsten

    2012-02-01

    Time-dependent density-functional theory allows one to calculate excitation energies and the associated transition densities in principle exactly. The transition density matrix (TDM) provides additional information on electron-hole localization and coherence of specific excitations of the many-body system. We have extended the TDM concept into the real-time domain in order to visualize the excited-state dynamics in conjugated molecules. The time-dependent TDM is defined as an implicit density functional, and can be approximately obtained from the time-dependent Kohn-Sham orbitals. The quality of this approximation is assessed in simple model systems. A computational scheme for real molecular systems is presented: the time-dependent Kohn-Sham equations are solved with the OCTOPUS code and the time-dependent Kohn-Sham TDM is calculated using a spatial partitioning scheme. The method is applied to show in real time how locally created electron-hole pairs spread out over neighboring conjugated molecular chains. The coupling mechanism, electron-hole coherence, and the possibility of charge separation are discussed.

  15. Computational complexity of time-dependent density functional theory

    International Nuclear Information System (INIS)

    Whitfield, J D; Yung, M-H; Tempel, D G; Aspuru-Guzik, A; Boixo, S

    2014-01-01

    Time-dependent density functional theory (TDDFT) is rapidly emerging as a premier method for solving dynamical many-body problems in physics and chemistry. The mathematical foundations of TDDFT are established through the formal existence of a fictitious non-interacting system (known as the Kohn–Sham system), which can reproduce the one-electron reduced probability density of the actual system. We build upon these works and show that on the interior of the domain of existence, the Kohn–Sham system can be efficiently obtained given the time-dependent density. We introduce a V-representability parameter which diverges at the boundary of the existence domain and serves to quantify the numerical difficulty of constructing the Kohn-Sham potential. For bounded values of V-representability, we present a polynomial time quantum algorithm to generate the time-dependent Kohn–Sham potential with controllable error bounds. (paper)

  16. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    Energy Technology Data Exchange (ETDEWEB)

    Kotsikoris, Ioannis, E-mail: gkotsikoris@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Zygomalas, Apollon, E-mail: azygomalas@upatras.gr [Department of General Surgery, University Hospital of Patras (Greece); Papas, Theofanis, E-mail: pfanis@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Maras, Dimitris, E-mail: dimmaras@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Pavlidis, Polyvios, E-mail: polpavlidis@yahoo.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Andrikopoulou, Maria, E-mail: madric@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Tsanis, Antonis, E-mail: atsanis@gmail.com [Department of Interventional Radiology, “Erythros Stauros” General Hospital (Greece); Alivizatos, Vasileios, E-mail: valiviz@hol.gr [Department of General Surgery and Artificial Nutrition Unit, “Agios Andreas” General Hospital of Patras (Greece); Bessias, Nikolaos, E-mail: bessias@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece)

    2012-09-15

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates.

  17. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    International Nuclear Information System (INIS)

    Kotsikoris, Ioannis; Zygomalas, Apollon; Papas, Theofanis; Maras, Dimitris; Pavlidis, Polyvios; Andrikopoulou, Maria; Tsanis, Antonis; Alivizatos, Vasileios; Bessias, Nikolaos

    2012-01-01

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates

  18. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors.

    Science.gov (United States)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F

    2010-01-01

    Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Videos sequences of 31 consecutive patients for at least 60s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10cm depths, whereas all other parameters showed only satisfying results at 4-6cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  19. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    Energy Technology Data Exchange (ETDEWEB)

    Ignee, Andre [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: andre.ignee@gmx.de; Jedrejczyk, Maciej [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: mjedrzejczyk@interia.pl; Schuessler, Gudrun [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: gudrunschuessler@gmx.de; Jakubowski, Wieslaw [Department of Diagnostic Imaging, 2nd Division of Medical Faculty, Medical University, Ul. Kondratowicza 8, 03-242 Warsaw (Poland)], E-mail: ewajbmd@go2.pl; Dietrich, Christoph F. [Department of Internal Medicine and Diagnostic Imaging, Caritas Hospital, Uhlandstr. 7, 97990 Bad Mergentheim (Germany)], E-mail: christoph.dietrich@ckbm.de

    2010-01-15

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  20. Quantitative contrast enhanced ultrasound of the liver for time intensity curves-Reliability and potential sources of errors

    International Nuclear Information System (INIS)

    Ignee, Andre; Jedrejczyk, Maciej; Schuessler, Gudrun; Jakubowski, Wieslaw; Dietrich, Christoph F.

    2010-01-01

    Introduction: Time intensity curves for real-time contrast enhanced low MI ultrasound is a promising technique since it adds objective data to the more subjective conventional contrast enhanced technique. Current developments showed that the amount of uptake in modern targeted therapy strategies correlates with therapy response. Nevertheless no basic research has been done concerning the reliability and validity of the method. Patients and methods: Videos sequences of 31 consecutive patients for at least 60 s were recorded. Parameters analysed: area under the curve, maximum intensity, mean transit time, perfusion index, time to peak, rise time. The influence of depth, lateral shift as well as size and shape of the region of interest was analysed. Results: The parameters time to peak and rise time showed a good stability in different depths. Overall there was a variation >50% for all other parameters. Mean transit time, time to peak and rise time were stable from 3 to 10 cm depths, whereas all other parameters showed only satisfying results at 4-6 cm. Time to peak and rise time were stable as well against lateral shifting whereas all other parameters had again variations over 50%. Size and shape of the region of interest did not influence the results. Discussion: (1) It is important to compare regions of interest, e.g. in a tumour vs. representative parenchyma in the same depths. (2) Time intensity curves should not be analysed in a depth of less than 4 cm. (3) The parameters area under the curve, perfusion index and maximum intensity should not be analysed in a depth more than 6 cm. (4) Size and shape of a region of interest in liver parenchyma do not affect time intensity curves.

  1. JUMPING THE CURVE

    Directory of Open Access Journals (Sweden)

    René Pellissier

    2012-01-01

    Full Text Available This paper explores the notion ofjump ing the curve,following from Handy 's S-curve onto a new curve with new rules policies and procedures. . It claims that the curve does not generally lie in wait but has to be invented by leadership. The focus of this paper is the identification (mathematically and inferentially ofthat point in time, known as the cusp in catastrophe theory, when it is time to change - pro-actively, pre-actively or reactively. These three scenarios are addressed separately and discussed in terms ofthe relevance ofeach.

  2. Current density and polarization curves for radial flow field patterns applied to PEMFCs (Proton Exchange Membrane Fuel Cells)

    International Nuclear Information System (INIS)

    Cano-Andrade, S.; Hernandez-Guerrero, A.; Spakovsky, M.R. von; Damian-Ascencio, C.E.; Rubio-Arana, J.C.

    2010-01-01

    A numerical solution of the current density and velocity fields of a 3-D PEM radial configuration fuel cell is presented. The energy, momentum and electrochemical equations are solved using a computational fluid dynamics (CFD) code based on a finite volume scheme. There are three cases of principal interest for this radial model: four channels, eight channels and twelve channels placed in a symmetrical path over the flow field plate. The figures for the current-voltage curves for the three models proposed are presented, and the main factors that affect the behavior of each of the curves are discussed. Velocity contours are presented for the three different models, showing how the fuel cell behavior is affected by the velocity variations in the radial configuration. All these results are presented for the case of high relative humidity. The favorable results obtained for this unconventional geometry seems to indicate that this geometry could replace the conventional commercial geometries currently in use.

  3. Time course of attentional modulation in the frontal eye field during curve tracing

    NARCIS (Netherlands)

    Khayat, P. S.; Pooresmaeili, A.; Roelfsema, P. R.

    2009-01-01

    Neurons in the frontal eye fields (FEFs) register incoming visual information and select visual stimuli that are relevant for behavior. Here we investigated the timing of the visual response and the timing of selection by recording from single FEF neurons in a curve-tracing task that requires shifts

  4. Time Course of Attentional Modulation in the Frontal Eye Field During Curve Tracing

    NARCIS (Netherlands)

    Khayat, P.S.; Pooresmaeili, A.; Roelfsema, P.R.

    2009-01-01

    Neurons in the frontal eye fields (FEFs) register incoming visual information and select visual stimuli that are relevant for behavior. Here we investigated the timing of the visual response and the timing of selection by recording from single FEF neurons in a curve-tracing task that requires shifts

  5. Momentum-subtraction renormalization techniques in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Foda, O.

    1987-10-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should.

  6. Momentum-subtraction renormalization techniques in curved space-time

    International Nuclear Information System (INIS)

    Foda, O.

    1987-01-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should

  7. Historical Cost Curves for Hydrogen Masers and Cesium Beam Frequency and Timing Standards

    Science.gov (United States)

    Remer, D. S.; Moore, R. C.

    1985-01-01

    Historical cost curves were developed for hydrogen masers and cesium beam standards used for frequency and timing calibration in the Deep Space Network. These curves may be used to calculate the cost of future hydrogen masers or cesium beam standards in either future or current dollars. The cesium beam standards are decreasing in cost by about 2.3% per year since 1966, and hydrogen masers are decreasing by about 0.8% per year since 1978 relative to the National Aeronautics and Space Administration inflation index.

  8. Micro-angiographic system using synchrotron radiation and conventional x-ray source for visualizing angiogenic vessels induced by cardiovascular regeneration therapy

    International Nuclear Information System (INIS)

    Mori, H.; Chiku, M.; Nishigami, K.; Tanaka, E.; Kimura, K.; Kawai, T.; Suzuki, K.; Mochizuki, R.; Okawa, Y.

    2004-01-01

    Therapeutic angiogenesis improved critical limb and myocardial ischemia in human, however, angiogenic vessels were not visualized well by conventional angiography, because of its limited spatial resolution of 200 μm. Recently, synchrotron radiation system characterized by high brightness, monochromatic and collimated nature revealed the micro-vessels of heart and lower limb in situ. We developed also an in-house microangiographic system with a relatively low cost. Limb ischemia models were made by ligature of femoral artery and treated by angiogenic growth factor genes and so on. One month after the treatment, we evaluated collateral micro-vessels by using the conventional and micro-angiographic systems. The approach was left femoral artery, and catheter was located in abdominal aorta. Iodine contrast (300 mg/ml) was injected 5 ml by 3 ml/sec with auto-injection system. The imaging was recorded by digital source in 1000 x 1000 pixels. The micro-angiographic system could detect the micro-vessels more precisely than conventional angiographic system and evaluate their function. (author)

  9. Angiographically Negative Acute Arterial Upper and Lower Gastrointestinal Bleeding: Incidence, Predictive Factors, and Clinical Outcomes

    International Nuclear Information System (INIS)

    Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Chae, Eun Young; Myung, Seung Jae; Ko, Gi Young; Gwon, Dong Il; Sung, Kyu Bo

    2009-01-01

    To evaluate the incidence, predictive factors, and clinical outcomes of angiographically negative acute arterial upper and lower gastrointestinal (GI) bleeding. From 2001 to 2008, 143 consecutive patients who underwent an angiography for acute arterial upper or lower GI bleeding were examined. The angiographies revealed a negative bleeding focus in 75 of 143 (52%) patients. The incidence of an angiographically negative outcome was significantly higher in patients with a stable hemodynamic status (p < 0.001), or in patients with lower GI bleeding (p = 0.032). A follow-up of the 75 patients (range: 0-72 months, mean: 8 ± 14 months) revealed that 60 of the 75 (80%) patients with a negative bleeding focus underwent conservative management only, and acute bleeding was controlled without rebleeding. Three of the 75 (4%) patients underwent exploratory surgery due to prolonged bleeding; however, no bleeding focus was detected. Rebleeding occurred in 12 of 75 (16%) patients. Of these, six patients experienced massive rebleeding and died of disseminated intravascular coagulation within four to nine hours after the rebleeding episode. Four of the 16 patients underwent a repeat angiography and the two remaining patients underwent a surgical intervention to control the bleeding. Angiographically negative results are relatively common in patients with acute GI bleeding, especially in patients with a stable hemodynamic status or lower GI bleeding. Most patients with a negative bleeding focus have experienced spontaneous resolution of their condition

  10. Angiographically Negative Acute Arterial Upper and Lower Gastrointestinal Bleeding: Incidence, Predictive Factors, and Clinical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Chae, Eun Young; Myung, Seung Jae; Ko, Gi Young; Gwon, Dong Il; Sung, Kyu Bo [Asan Medical Center, Seoul (Korea, Republic of)

    2009-08-15

    To evaluate the incidence, predictive factors, and clinical outcomes of angiographically negative acute arterial upper and lower gastrointestinal (GI) bleeding. From 2001 to 2008, 143 consecutive patients who underwent an angiography for acute arterial upper or lower GI bleeding were examined. The angiographies revealed a negative bleeding focus in 75 of 143 (52%) patients. The incidence of an angiographically negative outcome was significantly higher in patients with a stable hemodynamic status (p < 0.001), or in patients with lower GI bleeding (p = 0.032). A follow-up of the 75 patients (range: 0-72 months, mean: 8 {+-} 14 months) revealed that 60 of the 75 (80%) patients with a negative bleeding focus underwent conservative management only, and acute bleeding was controlled without rebleeding. Three of the 75 (4%) patients underwent exploratory surgery due to prolonged bleeding; however, no bleeding focus was detected. Rebleeding occurred in 12 of 75 (16%) patients. Of these, six patients experienced massive rebleeding and died of disseminated intravascular coagulation within four to nine hours after the rebleeding episode. Four of the 16 patients underwent a repeat angiography and the two remaining patients underwent a surgical intervention to control the bleeding. Angiographically negative results are relatively common in patients with acute GI bleeding, especially in patients with a stable hemodynamic status or lower GI bleeding. Most patients with a negative bleeding focus have experienced spontaneous resolution of their condition.

  11. Comparison of 21G curved and straight phacotips designs in transversal microcoaxial phacoemulsification

    Directory of Open Access Journals (Sweden)

    Süleyman Demircan

    2015-12-01

    Full Text Available AIM:To compare the intraoperative performance and postoperative outcomes after microcoaxial torsional phacoemulsification using the straight and the curved phacotip configurations.METHODS:Cataracts were treated using 2.2mm microcoaxial transversal phacoemulsification with either a 30°straight or 30° curved phaco tip. Intraoperative measurements analyzed included the average ultrasound(U/Spower, the total phacoemulsification time, and the effective phacoemulsification time(EPT. The central endothelial cell density(ECDand the central corneal thickness(CCTwere evaluated preoperatively and postoperatively at 1, 7 and 30d after surgery using noncontact specular microscopy. RESULTS:The study enrolled a total of 190 eyes(190 patients, 95 eyes in the curved tip group and 95 eyes in straight tip group. Intraoperative measurements showed significantly reduced total phacoemulsification time, and EPT in the curved-tip group, compared to the straight-tip group(Pst-3rd quartilesand 18.0(9.0-30.0s in curved-tip group, and 38.8(16.5-73.5s and 26.0(11.0-49.0s in the straight-tip group, respectively. CONCLUSION:Transversal phacoemulsification performed with a curved tip provided more effective lens removal with a less total UST and EPT in all grades, except for grades IV, compared to a straight tip.

  12. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  13. Simulation of time curves in small animal PET using GATE

    International Nuclear Information System (INIS)

    Simon, Luc; Strul, Daniel; Santin, Giovanni; Krieguer, Magalie; Morel, Christian

    2004-01-01

    The ClearPET project of the Crystal Clear Collaboration (CCC) is building spin-off technology for high resolution small animal Positron Emission Tomography (PET). Monte Carlo simulation is essential for optimizing the specifications of these systems with regards to their most important characteristics, such as spatial resolution, sensitivity, or count rate performance. GATE, the Geant4 Application for Tomographic Emission simulates the passing of time during real acquisitions, allowing to handle dynamic systems such as decaying source distributions or moving detectors. GATE output is analyzed on an event-by-event basis. The time associated with each single event allows to sort coincidences and to model dead-time. This leads to the study of time curves for a prospective small animal PET scanner design. The count rates of true, and random coincidences are discussed together with the corresponding Noise Equivalent Count (NEC) rates as a function of some PET scanner specifications such as detector dead time, or coincidence time window

  14. Rational points, rational curves, and entire holomorphic curves on projective varieties

    CERN Document Server

    Gasbarri, Carlo; Roth, Mike; Tschinkel, Yuri

    2015-01-01

    This volume contains papers from the Short Thematic Program on Rational Points, Rational Curves, and Entire Holomorphic Curves and Algebraic Varieties, held from June 3-28, 2013, at the Centre de Recherches Mathématiques, Université de Montréal, Québec, Canada. The program was dedicated to the study of subtle interconnections between geometric and arithmetic properties of higher-dimensional algebraic varieties. The main areas of the program were, among others, proving density of rational points in Zariski or analytic topology on special varieties, understanding global geometric properties of rationally connected varieties, as well as connections between geometry and algebraic dynamics exploring new geometric techniques in Diophantine approximation.

  15. Craniocervical artery dissection: MR imaging and MR angiographic findings

    International Nuclear Information System (INIS)

    Oelerich, M.; Schuierer, G.; Stoegbauer, F.; Kurlemann, G.; Schul, C.

    1999-01-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.)

  16. Craniocervical artery dissection: MR imaging and MR angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Oelerich, M.; Schuierer, G. [Institute of Clinical Radiology, University of Muenster (Germany); Stoegbauer, F. [Department of Neurology, University of Muenster (Germany); Kurlemann, G. [Department of Pediatric Neurology, University of Muenster (Germany); Schul, C. [Department of Neurosurgery, University of Muenster (Germany)

    1999-09-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.) With 6 figs., 2 tabs., 33 refs.

  17. Angiographic examinations of the circulatory development of living chick embryos

    International Nuclear Information System (INIS)

    Stoeter, P.; Buchhoecker, M.; Bruzek, W.; Drews, U.; Schulze, K.; Tuebingen Univ.; Tuebingen Univ.

    1980-01-01

    In chick embryos of an age of incubation of 5-14 days, the physiological development of the circulation and the morphological differentation of the arterical system were studied by intravital and postmortal angiography. For the examinations of the living embryos, a special radiographic and injection technique had to be developed. The contrast medium was injected into the umbilical veins and transported by the actions of the embryonic heart. Continuous ECG recordings showed no marked interference of the injections with the cardiac activity. According to the angiographic findings, the circulation is relatively fast within the main arteries, but the capillary perfusion is prolonged and lasts up to several minutes. The average circulatory velocity of the blood stream within the carotid artery increases parallel to the arterial enlargement, whereas the circulatory time decreases and the number of heart beats during the period of carotid opacification does not change to a great extent. By this, a steady transport of gas and nutritional material may be achieved in the growing arterial system. (orig.) [de

  18. Dual Smarandache Curves of a Timelike Curve lying on Unit dual Lorentzian Sphere

    OpenAIRE

    Kahraman, Tanju; Hüseyin Ugurlu, Hasan

    2016-01-01

    In this paper, we give Darboux approximation for dual Smarandache curves of time like curve on unit dual Lorentzian sphere. Firstly, we define the four types of dual Smarandache curves of a timelike curve lying on dual Lorentzian sphere.

  19. Angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid artery

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Han, Moon Hee; Chang, Kee Hyun; Han, Gi Seok; Yeon, Kung Mo

    1995-01-01

    The purpose of this study is to describe the angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid arteries and to evaluate the extent of angiographic assessment needed before embolization. We retrospectively reviewed 10 cervicofacial vascular lesions with previously ligated carotid artery, which were 6 cases of arteriovenous malformation, 2 cases of carotid cavernous fistula, 1 case of hemangioma and 1 case of arteriovenous malformation with carotid cavernous fistula. The previously ligated arteries are proximal external carotid artery (n = 5), branches of external carotid artery (n = 2) and common carotid artery (n = 3). Common carotid artery or internal carotid artery (n = 9), vertebral artery (n = 5), ipsilateral external carotid artery (n = 4), contralateral external carotid artery (n = 5), costocervical trunk (n = 2), thyrocervical trunk (n = 2) were assessed by conventional angiography. Angiography of both carotid and vertebral arteries was performed in 5 cases. The collateral vascular channels were inferolateral trunk of internal carotid artery (n = 8), vertebral artery (n = 5), contralateral external carotid artery (n = 5), ipsilateral external carotid artery (n = 4), deep cervical artery (n = 2) and ascending cervical artery (n = 1). Embolization were performed in 9 cases with operative cannulation (n = 4), embolization via collateral branches of ipsilateral external carotid artery (n = 1), embolization via collateral branches of contralateral external carotid artery (n = 3) and balloon occlusion via direct puncture (n = 1). The collateral channels in cervicofacial vascular lesions with previously ligated carotid artery were inferolateral trunk of internal carotid artery, contralateral or ipsilateral external carotid artery, vertebral artery, deep cervical artery and ascending cervical artery on angiography. Complete angiographic assessment of possible collateral channels is mandatory for the

  20. Theoretical determination of transit time locus curves for ultrasonic pulse echo testing - ALOK. Pt. 4

    International Nuclear Information System (INIS)

    Grohs, B.

    1983-01-01

    The ALOK-technique allows the simultaneous detection of flaws and their evaluation with respect to type, location and dimension by interpretation of the transit time behaviour during scanning of the reflector. The accuracy of information obtained by means of this technique can be further improved both during interference elimination and reconstruction owing to the ability of exact calculation of possible transit time locus curves of given reflectors. The mathematical solution of transit time locus curve calculations refers here to pulse echo testing in consideration of the refraction of sound on the forward wedge/test object - interface. The method of solving the problem is equivalent to the Fermat's principle in optics. (orig.) [de

  1. A characteristic of angiographic cone-beam CT

    International Nuclear Information System (INIS)

    Takase, Tadashi; Take, Toshio; Nakazawa, Yasuo; Kinouchi, Katsunori

    2009-01-01

    Angiographic cone-beam CT, called DynaCT by SIEMENS, is a 3D imaging tool reconstructed from projection data by a rotational C-arm with a flat panel detector. It can visualize low-contrast objects such as soft tissue or small vessels as well as high-contrast structures such as enhanced vessels or bone. We need to understand its image characteristics and dose distribution during 200 degree rotation around a patient. In this research, we evaluated fundamental characteristics and dose effectiveness for optimized clinical images. DynaCT, including soft tissue information and isochronal voxel data along the z-axis, could provide enough CT-like image quality for interventional radiology (IVR) use. In addition, evaluation of accumulated dose distribution helped us to predict and avoid the occurrence of radiodermatitis. Thus, DynaCT is useful as a support and navigation tool for IVR. (author)

  2. Development of p-y curves of laterally loaded piles in cohesionless soil.

    Science.gov (United States)

    Khari, Mahdy; Kassim, Khairul Anuar; Adnan, Azlan

    2014-01-01

    The research on damages of structures that are supported by deep foundations has been quite intensive in the past decade. Kinematic interaction in soil-pile interaction is evaluated based on the p-y curve approach. Existing p-y curves have considered the effects of relative density on soil-pile interaction in sandy soil. The roughness influence of the surface wall pile on p-y curves has not been emphasized sufficiently. The presented study was performed to develop a series of p-y curves for single piles through comprehensive experimental investigations. Modification factors were studied, namely, the effects of relative density and roughness of the wall surface of pile. The model tests were subjected to lateral load in Johor Bahru sand. The new p-y curves were evaluated based on the experimental data and were compared to the existing p-y curves. The soil-pile reaction for various relative density (from 30% to 75%) was increased in the range of 40-95% for a smooth pile at a small displacement and 90% at a large displacement. For rough pile, the ratio of dense to loose relative density soil-pile reaction was from 2.0 to 3.0 at a small to large displacement. Direct comparison of the developed p-y curve shows significant differences in the magnitude and shapes with the existing load-transfer curves. Good comparison with the experimental and design studies demonstrates the multidisciplinary applications of the present method.

  3. Development of p-y Curves of Laterally Loaded Piles in Cohesionless Soil

    Science.gov (United States)

    Khari, Mahdy; Kassim, Khairul Anuar; Adnan, Azlan

    2014-01-01

    The research on damages of structures that are supported by deep foundations has been quite intensive in the past decade. Kinematic interaction in soil-pile interaction is evaluated based on the p-y curve approach. Existing p-y curves have considered the effects of relative density on soil-pile interaction in sandy soil. The roughness influence of the surface wall pile on p-y curves has not been emphasized sufficiently. The presented study was performed to develop a series of p-y curves for single piles through comprehensive experimental investigations. Modification factors were studied, namely, the effects of relative density and roughness of the wall surface of pile. The model tests were subjected to lateral load in Johor Bahru sand. The new p-y curves were evaluated based on the experimental data and were compared to the existing p-y curves. The soil-pile reaction for various relative density (from 30% to 75%) was increased in the range of 40–95% for a smooth pile at a small displacement and 90% at a large displacement. For rough pile, the ratio of dense to loose relative density soil-pile reaction was from 2.0 to 3.0 at a small to large displacement. Direct comparison of the developed p-y curve shows significant differences in the magnitude and shapes with the existing load-transfer curves. Good comparison with the experimental and design studies demonstrates the multidisciplinary applications of the present method. PMID:24574932

  4. Development of p-y Curves of Laterally Loaded Piles in Cohesionless Soil

    Directory of Open Access Journals (Sweden)

    Mahdy Khari

    2014-01-01

    Full Text Available The research on damages of structures that are supported by deep foundations has been quite intensive in the past decade. Kinematic interaction in soil-pile interaction is evaluated based on the p-y curve approach. Existing p-y curves have considered the effects of relative density on soil-pile interaction in sandy soil. The roughness influence of the surface wall pile on p-y curves has not been emphasized sufficiently. The presented study was performed to develop a series of p-y curves for single piles through comprehensive experimental investigations. Modification factors were studied, namely, the effects of relative density and roughness of the wall surface of pile. The model tests were subjected to lateral load in Johor Bahru sand. The new p-y curves were evaluated based on the experimental data and were compared to the existing p-y curves. The soil-pile reaction for various relative density (from 30% to 75% was increased in the range of 40–95% for a smooth pile at a small displacement and 90% at a large displacement. For rough pile, the ratio of dense to loose relative density soil-pile reaction was from 2.0 to 3.0 at a small to large displacement. Direct comparison of the developed p-y curve shows significant differences in the magnitude and shapes with the existing load-transfer curves. Good comparison with the experimental and design studies demonstrates the multidisciplinary applications of the present method.

  5. The time-dependent density matrix renormalisation group method

    Science.gov (United States)

    Ma, Haibo; Luo, Zhen; Yao, Yao

    2018-04-01

    Substantial progress of the time-dependent density matrix renormalisation group (t-DMRG) method in the recent 15 years is reviewed in this paper. By integrating the time evolution with the sweep procedures in density matrix renormalisation group (DMRG), t-DMRG provides an efficient tool for real-time simulations of the quantum dynamics for one-dimensional (1D) or quasi-1D strongly correlated systems with a large number of degrees of freedom. In the illustrative applications, the t-DMRG approach is applied to investigate the nonadiabatic processes in realistic chemical systems, including exciton dissociation and triplet fission in polymers and molecular aggregates as well as internal conversion in pyrazine molecule.

  6. Recurrent bleeding after arterial embolization in patients with hemoptysis : Comparison of angiographic findings and relapsing period

    International Nuclear Information System (INIS)

    Park, Sung Keun; Choi, Seok Jin; Choi, Gi Bok; Kim, Hae Yeon; Park, Auh Whan; Juhn, Jae Ryang; Cha, Seong Sook

    2001-01-01

    To describe the angiographic findings of patients with recurrent hemoptysis after bronchial artery embolization (BAE) according to the point at which relapse occurred. From 125 patients who underwent BAE due to hemoptysis between 1996 and 2000, we selected 18 of 23 who underwent additional BAE due to recurrent bleeding after initial BAE. Depending on the point at which relapse occurred, they were divided into two groups (I and ll, according to whether additional BAE was performed within two weeks of initial BAE or more than two weeks after this) We retrospectively compared the two groups in terms of angiographic findings, number of embolized arteries, and character of feeding arteries at initial and additional BAE. Nine patients in group I (additional BAE: n=10) and nine in group ll (additional BAE: n=13) were admitted for recurrent hemoptysis within two weeks of initial BAE and more than two weeks after this, respectively. In group I (n=29) and ll(n=31), angiography demonstrated two direct and 27 indirect, and two direct and 29 indirect signs of hemorrhage, respectiveIy. No statistically significant differences were observed (x 2 =0.005, ρ=0.945). Among the embolized feeder ressels in group I (n=30) there were 20 bronchial artery and 10 non bronchial systemic collaterals, while for group ll (n=35), the corresponding totals were 21 and 14. Again, no statistically significant differences were encountered(x 2 =0.308; ρ=0.579). In group I, feeders were newly developed in one case(10%), previously embolized in five(50%), and missed in four(40%), while in group two the corresponding figures were none, twelve(92.3%), and one(7.7%) No significant differences were noted, though the incidence of previously embolized feeders in Group ll was very high (x 2 =5.383, ρ=0.068). Among patients in whom hemoptysis after BAE recurred at different times, the angiographic findings and number of embolized arteries were not significantly different, but differences in the nature of the

  7. SU-E-J-122: The CBCT Dose Calculation Using a Patient Specific CBCT Number to Mass Density Conversion Curve Based On a Novel Image Registration and Organ Mapping Method in Head-And-Neck Radiation Therapy

    International Nuclear Information System (INIS)

    Zhou, J; Lasio, G; Chen, S; Zhang, B; Langen, K; Prado, K; D’Souza, W; Yi, B; Huang, J

    2015-01-01

    Purpose: To develop a CBCT HU correction method using a patient specific HU to mass density conversion curve based on a novel image registration and organ mapping method for head-and-neck radiation therapy. Methods: There are three steps to generate a patient specific CBCT HU to mass density conversion curve. First, we developed a novel robust image registration method based on sparseness analysis to register the planning CT (PCT) and the CBCT. Second, a novel organ mapping method was developed to transfer the organs at risk (OAR) contours from the PCT to the CBCT and corresponding mean HU values of each OAR were measured in both the PCT and CBCT volumes. Third, a set of PCT and CBCT HU to mass density conversion curves were created based on the mean HU values of OARs and the corresponding mass density of the OAR in the PCT. Then, we compared our proposed conversion curve with the traditional Catphan phantom based CBCT HU to mass density calibration curve. Both curves were input into the treatment planning system (TPS) for dose calculation. Last, the PTV and OAR doses, DVH and dose distributions of CBCT plans are compared to the original treatment plan. Results: One head-and-neck cases which contained a pair of PCT and CBCT was used. The dose differences between the PCT and CBCT plans using the proposed method are −1.33% for the mean PTV, 0.06% for PTV D95%, and −0.56% for the left neck. The dose differences between plans of PCT and CBCT corrected using the CATPhan based method are −4.39% for mean PTV, 4.07% for PTV D95%, and −2.01% for the left neck. Conclusion: The proposed CBCT HU correction method achieves better agreement with the original treatment plan compared to the traditional CATPhan based calibration method

  8. SU-E-J-122: The CBCT Dose Calculation Using a Patient Specific CBCT Number to Mass Density Conversion Curve Based On a Novel Image Registration and Organ Mapping Method in Head-And-Neck Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, J [University of Maryland School of Medicine, Bel Air, MD (United States); Lasio, G; Chen, S; Zhang, B; Langen, K; Prado, K; D’Souza, W [University of Maryland School of Medicine, Baltimore, MD (United States); Yi, B [Univ. of Maryland School Of Medicine, Baltimore, MD (United States); Huang, J [University of Texas at Arlington, Arlington, TX (United States)

    2015-06-15

    Purpose: To develop a CBCT HU correction method using a patient specific HU to mass density conversion curve based on a novel image registration and organ mapping method for head-and-neck radiation therapy. Methods: There are three steps to generate a patient specific CBCT HU to mass density conversion curve. First, we developed a novel robust image registration method based on sparseness analysis to register the planning CT (PCT) and the CBCT. Second, a novel organ mapping method was developed to transfer the organs at risk (OAR) contours from the PCT to the CBCT and corresponding mean HU values of each OAR were measured in both the PCT and CBCT volumes. Third, a set of PCT and CBCT HU to mass density conversion curves were created based on the mean HU values of OARs and the corresponding mass density of the OAR in the PCT. Then, we compared our proposed conversion curve with the traditional Catphan phantom based CBCT HU to mass density calibration curve. Both curves were input into the treatment planning system (TPS) for dose calculation. Last, the PTV and OAR doses, DVH and dose distributions of CBCT plans are compared to the original treatment plan. Results: One head-and-neck cases which contained a pair of PCT and CBCT was used. The dose differences between the PCT and CBCT plans using the proposed method are −1.33% for the mean PTV, 0.06% for PTV D95%, and −0.56% for the left neck. The dose differences between plans of PCT and CBCT corrected using the CATPhan based method are −4.39% for mean PTV, 4.07% for PTV D95%, and −2.01% for the left neck. Conclusion: The proposed CBCT HU correction method achieves better agreement with the original treatment plan compared to the traditional CATPhan based calibration method.

  9. Effect of Asparagus racemosus on fracture healing in rabbits: a radiographic and angiographic study

    International Nuclear Information System (INIS)

    Singh, Sunil; Singh, H.N.; Gangwar, A.K.; Devi, Kh. Sangeeta; Waghay, J.Y.

    2009-01-01

    New Zealand white rabbits (18) were randomly divided into groups I and II (control) having 9 animals in each group. The fracture of ulna was created in each animal under general anaesthesia using thiopental sodium (2.5%). Radius acted as a natural splint. The animals of group I were fed with powdered Asparagus racemosus along with rabbit feed throughout the study period. However, in group II animals only powdered rabbit feed was given. Healing at the fracture site was assessed by plain radiography and angiography at 7th, 14th, 21st and 28th day interval. Radiographical observation revealed a well organized and dense callus at 21st day in animals of group I whereas in animals of group II, callus of slightly less radiographic density was observed at this interval. Angiographic observation revealed hypervascularity at the fracture site at 7th and 14th day interval in group I animals. On day 14, in group II animals major vessels lack continuity along with reduced vascularity around the fracture site. The results of present study suggest that feeding of dry root powder of Asparagus racemosus promotes early fracture healing in rabbits

  10. Superselective angiographic findings and the blood supply in the cases of avascular necrosis of the femoral head: a preliminary study

    International Nuclear Information System (INIS)

    Zhou Weisheng; Wang Fangjun; Ling Yisheng; Zhao Tianqing

    2003-01-01

    Objective: To study the superselective angiographic findings and blood supply in the case of avascular necrosis of the femoral head (ANFH). Methods: One hundred and sixty five patients (214 hips) with ANFH proved by clinic and radiology underwent superselective angiography and DSA findings were retrospectively studied. Results: Abnormal angiographic findings of the medial circumflex artery and its branches, with or without other abnormal vascularities, could be obtained in 162 hips out of 211 (98.6%). Angiographic findings of ANFH were the followings: abnormal superior and inferior capsular branch of the medial circumflex artery, especially the former one; abnormalities in the ascending branch of lateral circumflex artery; opacification of the femoral head and neck in the parenchymal phase of DSA; revasculization of the small arterial branches or a hypervascular area surrounding the necrotic lesions; anastomosis between the medial circumflex artery and the inferior and superior gluteal arteries; and the venous stasis. Conclusion: Morphological changes of blood vessels in ANFH are demonstrated by superselective angiography, in which the medial circumflex artery and its branches are mostly involved, or in some cases, accompanied by venous stasis

  11. Interlaboratory comparison of the measurement of retention curves

    DEFF Research Database (Denmark)

    Hansen, M. H.; Houvenaghel, G.; Janz, M.

    1999-01-01

    The results of an interlaboratory comparison of the measurement of apparent density, solid density, open porosity and retention curves are presented. Baumberger sandstone and Sander sandstone were used as test materials.Repeatability standard deviation and reproducibility standard deviation...

  12. Methodology for developing and implementing alternative temperature-time curves for testing the fire resistance of barriers for nuclear power plant applications

    International Nuclear Information System (INIS)

    Cooper, L.Y.; Steckler, K.D.

    1996-08-01

    Advances in fire science over the past 40 years have offered the potential for developing technically sound alternative temperature-time curves for use in evaluating fire barriers for areas where fire exposures can be expected to be significantly different than the ASTM E-119 standard temperature-time exposure. This report summarizes the development of the ASTM E-119, standard temperature-time curve, and the efforts by the federal government and the petrochemical industry to develop alternative fire endurance curves for specific applications. The report also provides a framework for the development of alternative curves for application at nuclear power plants. The staff has concluded that in view of the effort necessary for the development of nuclear power plant specific temperature-time curves, such curves are not a viable approach for resolving the issues concerning Thermo-Lag fire barriers. However, the approach may be useful to licensees in the development of performance-based fire protection methods in the future

  13. Methodology for developing and implementing alternative temperature-time curves for testing the fire resistance of barriers for nuclear power plant applications

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, L.Y.; Steckler, K.D.

    1996-08-01

    Advances in fire science over the past 40 years have offered the potential for developing technically sound alternative temperature-time curves for use in evaluating fire barriers for areas where fire exposures can be expected to be significantly different than the ASTM E-119 standard temperature-time exposure. This report summarizes the development of the ASTM E-119, standard temperature-time curve, and the efforts by the federal government and the petrochemical industry to develop alternative fire endurance curves for specific applications. The report also provides a framework for the development of alternative curves for application at nuclear power plants. The staff has concluded that in view of the effort necessary for the development of nuclear power plant specific temperature-time curves, such curves are not a viable approach for resolving the issues concerning Thermo-Lag fire barriers. However, the approach may be useful to licensees in the development of performance-based fire protection methods in the future.

  14. Preoperative evaluation of hepatic arterial and portal venous anatomy using the time resolved echo-shared MR angiographic technique in living liver donors

    International Nuclear Information System (INIS)

    Lee, Min Woo; Lee, Jeong Min; Lee, Jae Young; Kim, Se Hyung; Park, Eun-Ah; Han, Joon Koo; Choi, Jin-Young; Choi, Byung Ihn; Kim, Young Jun; Suh, Kyung-Suk

    2007-01-01

    The purpose of this study was to determine whether MR angiography utilizing the time resolved echo-shared angiographic technique (TREAT) can provide an effective assessment of the hepatic artery (HA) and portal vein (PV) in living donor candidates. MR angiography (MRA)was performed in 27 patients (23 men and 4 women; mean age, 31 years) by using TREAT. Two blinded radiologists evaluated HA anatomy, origin of segment IV feeding artery and PV anatomy in consensus. Qualitative evaluations of MRA images were performed using the following criteria: (a) overall image quality, (b) presence of artifacts, and (c) degree of venous contamination of the arterial phase. Using intraoperative findings as a standard of reference, the accuracy for the HA anatomy, origin of segment IV feeding artery and PV anatomy on TREAT-MRA were 93% (25/27), 85% (23/27), and 96% (26/27), respectively. Overall image qualities were as follows: excellent (n=22, 81%), good (n=4, 15%), and fair (n=1, 4%). Significant artifacts or venous contamination of the arterial phase images was not noted in any patient. TREAT-MRA can provide a complete evaluation of HA and PV anatomy during preoperative evaluation of living liver donors. Furthermore, it provides a more detailed anatomy of the HA without venous contamination. (orig.)

  15. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    Science.gov (United States)

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  16. Quantitative stress-redistribution planar T1-201 scintigraphy: Assessment of the extent of hypoperfused myocardium by relationship to angiographic findings

    International Nuclear Information System (INIS)

    Bassir, R.; Maddahi, J.; Garcia, E.

    1984-01-01

    The size of hypoperfused myocardium (HM) in coronary artery (CA) disease (D) potentially provides a prognostic index that may not be accurately assess by conventional angiographic classification. The authors studied 62 consecutive patients (pts) with planar stress-redistribution T1-201 scintigraphy (T1-201) and coronary arteriography who did not have prior myocardial infarction and achieved 85% predicted maximum heart rate on exercise. Of 62 pts, 42 had CAD (>50% stenosis). For T1-201 quantification of the size of HM, maximum count circumferential profiles of initial distribution and % washout were obtained and compared to previously established normal limits. The area enclosed between the normal limits and the abnormal portion of the pt's profiles represented a quantitative T1-201 jeopardy score (JS). Despite increasing T1-201 JS from 1 to 3 vessel (V) and left-main (LM) D, significant overlap between the different angiographic groups was observed; of 45 pts with mild JS (<300), 14 (31%) had 3VD and/or LMD. The angiographic extent of CAD was also analyzed using a method (CLASS) proposed by Gensini et al based on the CA territory, location and severity of stenosis, and collateral circulation. T1-201 JS correlated significantly with CLASS (r=.78, p<.01). Of the 45 pts with mild JS, only 5 (11%) had severe CLASS score. Thus, the size of the hypoperfused myocardium by quantitative stress- and redistribution T1-201 correlates better with a more complex angiographic estimate of myocardium at risk than conventional 1, 2, and 3 vessel disease classification

  17. The implementation of real-time plasma electron density calculations on EAST

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z.C., E-mail: zzc@ipp.ac.cn; Xiao, B.J.; Wang, F.; Liu, H.Q.; Yuan, Q.P.; Wang, Y.; Yang, Y.

    2016-11-15

    Highlights: • The real-time density calculation system (DCS) has been applied to the EAST 3-wave polarimeter-interferometer (POINT) system. • The new system based on Flex RIO acquires data at high speed and processes them in a short time. • Roll-over module is developed for density calculation. - Abstract: The plasma electron density is one of the most fundamental parameters in tokamak experiment. It is widely used in the plasma control system (PCS) real-time control, as well as plasma physics analysis. The 3-wave polarimeter-interferometer (POINT) system had been used to measure the plasma electron density on the EAST since last campaign. This paper will give the way to realize the real-time measurement of plasma electron density. All intermediate frequency (IF) signals after POINT system, in the 0.5–3 MHz range, stream to the real-time density calculation system (DCS) to extract the phase shift information. All the prototype hardware is based on NI Flex RIO device which contains a high speed Field Programmable Gate Array (FPGA). The original signals are sampled at 10 M Samples/s, and the data after roll-over module are transmitted to PCS by reflective memory (RFM). With this method, real-time plasma electron density data with high accuracy and low noise had been obtained in the latest EAST tokamak experiment.

  18. Estimating reaction rate constants: comparison between traditional curve fitting and curve resolution

    NARCIS (Netherlands)

    Bijlsma, S.; Boelens, H. F. M.; Hoefsloot, H. C. J.; Smilde, A. K.

    2000-01-01

    A traditional curve fitting (TCF) algorithm is compared with a classical curve resolution (CCR) approach for estimating reaction rate constants from spectral data obtained in time of a chemical reaction. In the TCF algorithm, reaction rate constants an estimated from the absorbance versus time data

  19. CLINICAL AND ANGIOGRAPHIC PROFILE OF PATIENTS WITH COMPLETE HEART BLOCK

    Directory of Open Access Journals (Sweden)

    Kavya Pingali

    2017-05-01

    Full Text Available BACKGROUND The angiographic findings and prognosis of patients with Complete Heart Block (CHB remain unclear. Thus, we aimed to study the clinical profile, risk factors, angiographic distribution and in-hospital outcomes of patients with complete heart block. MATERIALS AND METHODS This was a prospective, single-centred study which included 100 patients who came to the emergency department with CHB. Routine blood investigations including serum electrolytes were done. Coronary angiogram was done and lesions were assessed. Temporary pacemaker was implanted followed by permanent pacemakers in required patients, and in-hospital complications were noted down. RESULTS Commonest age group was above 60 years (75%. The patients were predominantly males. Most common presentation was chest pain (60%; there was regional wall motion abnormality in 30% patients. Degenerative complete heart block was seen in 34% patients, diphtheric myocarditis in 15%, hypokalaemic in 15%, dilated cardiomyopathy in 2%. Of total 53 patients had AV block, 14 had bifascicular block, 23 had LBBB, 6 had RBBB, 3 had Mobitz I and 1 had Mobitz II. Inferior wall myocardial infarction (MI was pervasively present in patients. Temporary pacemakers were implanted in 6 patients and permanent pacemakers in 43 patients. In-hospital outcomes constituted of complication like cardiogenic shock (10% and death (26%. The patients who died either had 80% -90% stenosis in RCA, triple vessel disease, ostioproximal LAD occlusion or diphtheric myocarditis. CONCLUSION Complete heart block was majorly associated with advanced age and inferior wall MI, virtually caused by dominant RCA occlusion. The in-hospital mortality was significantly higher in the patients with CHB.

  20. A comprehensive tool for measuring mammographic density changes over time.

    Science.gov (United States)

    Eriksson, Mikael; Li, Jingmei; Leifland, Karin; Czene, Kamila; Hall, Per

    2018-06-01

    Mammographic density is a marker of breast cancer risk and diagnostics accuracy. Density change over time is a strong proxy for response to endocrine treatment and potentially a stronger predictor of breast cancer incidence. We developed STRATUS to analyse digital and analogue images and enable automated measurements of density changes over time. Raw and processed images from the same mammogram were randomly sampled from 41,353 healthy women. Measurements from raw images (using FDA approved software iCAD) were used as templates for STRATUS to measure density on processed images through machine learning. A similar two-step design was used to train density measures in analogue images. Relative risks of breast cancer were estimated in three unique datasets. An alignment protocol was developed using images from 11,409 women to reduce non-biological variability in density change. The protocol was evaluated in 55,073 women having two regular mammography screens. Differences and variances in densities were compared before and after image alignment. The average relative risk of breast cancer in the three datasets was 1.6 [95% confidence interval (CI) 1.3-1.8] per standard deviation of percent mammographic density. The discrimination was AUC 0.62 (CI 0.60-0.64). The type of image did not significantly influence the risk associations. Alignment decreased the non-biological variability in density change and re-estimated the yearly overall percent density decrease from 1.5 to 0.9%, p density measures was not influenced by mammogram type. The alignment protocol reduced the non-biological variability between images over time. STRATUS has the potential to become a useful tool for epidemiological studies and clinical follow-up.

  1. The Physics of Type Ia Supernova Light Curves. I. Analytic Results and Time Dependence

    International Nuclear Information System (INIS)

    Pinto, Philip A.; Eastman, Ronald G.

    2000-01-01

    We develop an analytic solution of the radiation transport problem for Type Ia supernovae (SNe Ia) and show that it reproduces bolometric light curves produced by more detailed calculations under the assumption of a constant-extinction coefficient. This model is used to derive the thermal conditions in the interior of SNe Ia and to study the sensitivity of light curves to various properties of the underlying supernova explosions. Although the model is limited by simplifying assumptions, it is adequate for demonstrating that the relationship between SNe Ia maximum-light luminosity and rate of decline is most easily explained if SNe Ia span a range in mass. The analytic model is also used to examine the size of various terms in the transport equation under conditions appropriate to maximum light. For instance, the Eulerian and advective time derivatives are each shown to be of the same order of magnitude as other order v/c terms in the transport equation. We conclude that a fully time-dependent solution to the transport problem is needed in order to compute SNe Ia light curves and spectra accurate enough to distinguish subtle differences of various explosion models. (c) 2000 The American Astronomical Society

  2. Automatic flow analysis of digital subtraction angiography using independent component analysis in patients with carotid stenosis.

    Directory of Open Access Journals (Sweden)

    Han-Jui Lee

    Full Text Available Current time-density curve analysis of digital subtraction angiography (DSA provides intravascular flow information but requires manual vasculature selection. We developed an angiographic marker that represents cerebral perfusion by using automatic independent component analysis.We retrospectively analyzed the data of 44 patients with unilateral carotid stenosis higher than 70% according to North American Symptomatic Carotid Endarterectomy Trial criteria. For all patients, magnetic resonance perfusion (MRP was performed one day before DSA. Fixed contrast injection protocols and DSA acquisition parameters were used before stenting. The cerebral circulation time (CCT was defined as the difference in the time to peak between the parietal vein and cavernous internal carotid artery in a lateral angiogram. Both anterior-posterior and lateral DSA views were processed using independent component analysis, and the capillary angiogram was extracted automatically. The full width at half maximum of the time-density curve in the capillary phase in the anterior-posterior and lateral DSA views was defined as the angiographic mean transient time (aMTT; i.e., aMTTAP and aMTTLat. The correlations between the degree of stenosis, CCT, aMTTAP and aMTTLat, and MRP parameters were evaluated.The degree of stenosis showed no correlation with CCT, aMTTAP, aMTTLat, or any MRP parameter. CCT showed a strong correlation with aMTTAP (r = 0.67 and aMTTLat (r = 0.72. Among the MRP parameters, CCT showed only a moderate correlation with MTT (r = 0.67 and Tmax (r = 0.40. aMTTAP showed a moderate correlation with Tmax (r = 0.42 and a strong correlation with MTT (r = 0.77. aMTTLat also showed similar correlations with Tmax (r = 0.59 and MTT (r = 0.73.Apart from vascular anatomy, aMTT estimates brain parenchyma hemodynamics from DSA and is concordant with MRP. This process is completely automatic and provides immediate measurement of quantitative peritherapeutic brain parenchyma

  3. Should incidental asymptomatic angiographic stenoses and occlusions be treated in patients with peripheral arterial disease?

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2009-09-01

    The clinical importance of angiographically detected asymptomatic lower-limb stenoses and occlusions is unknown. This study aims to (i) assess the clinical outcome of asymptomatic lesions in the lower limb, (ii) identify predictors of clinical deterioration, and (iii) determine which asymptomatic lower-limb lesions should be treated at presentation.

  4. Angiographic Findings and Embolotherapy in Renal Arterial Trauma

    International Nuclear Information System (INIS)

    Sofocleous, Constantinos T.; Hinrichs, Clay; Hubbi, Basil; Brountzos, Elias; Kaul, Sanjeev; Kannarkat, George; Bahramipour, Philip; Barone, Alison; Contractor, Daniel G.; Shah, Tanmaya

    2005-01-01

    Purpose To evaluate the angiographic findings and embolotherapy in the management of traumatic renal arterial injury Methods This is a retrospective review of 22 patients with renal trauma who underwent arteriography and percutaneous embolization from December 1995 to January 2002. Medical records, imaging studies and procedural reports were reviewed to assess the type of injury, arteriographic findings and immediate embolization results. Long-term clinical outcome was obtained by communication with the trauma physicians and by clinical chart review.Results Arteriography was performed in 125 patients admitted to a State Trauma Center with suspected internal bleeding. Renal arterial injury was documented in 22 and was the result of a motor-vehicle accident (10), auto-pedestrian accident (1), gunshot (4) or stab wounds (6) and a fall (1). Percutaneous renal arterial embolization was undertaken in 22 of 125 (18%) patients to treat extravasation (11), arterial pedicle rupture (5), abnormal arteriovenous (3) or arteriocalyceal (2) communication and pseudoaneurysm (3). One of the pseudoaneurysms and one of the arteriovenous fistulae were found in addition to extravasation. All 22 patients (16 men, 6 women) were hemodynamically stable, or controlled during arteriography and embolotherapy. Selective and/or superselective embolization of the abnormal vessels was performed using coils in 9 patients, microcoils in 9 patients and Gelfoam pledgets in 3 patients. In one patient Gelfoam pledgets mixed with polyvinyl alcohol (PVA) particles were used for embolization. Immediate angiographic evidence of hemostasis was demonstrated in all cases. Two initial technical failures were treated with repeat arteriography and embolization. There was no procedure-related death. There was no non-target embolization. One episode of renal abscess after embolization was treated by nephrectomy and 3 patients underwent elective post-embolization nephrectomy to prevent infection. Follow-up ranged

  5. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion

    OpenAIRE

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-01-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed...

  6. Time-dependent density-functional tight-binding method with the third-order expansion of electron density.

    Science.gov (United States)

    Nishimoto, Yoshio

    2015-09-07

    We develop a formalism for the calculation of excitation energies and excited state gradients for the self-consistent-charge density-functional tight-binding method with the third-order contributions of a Taylor series of the density functional theory energy with respect to the fluctuation of electron density (time-dependent density-functional tight-binding (TD-DFTB3)). The formulation of the excitation energy is based on the existing time-dependent density functional theory and the older TD-DFTB2 formulae. The analytical gradient is computed by solving Z-vector equations, and it requires one to calculate the third-order derivative of the total energy with respect to density matrix elements due to the inclusion of the third-order contributions. The comparison of adiabatic excitation energies for selected small and medium-size molecules using the TD-DFTB2 and TD-DFTB3 methods shows that the inclusion of the third-order contributions does not affect excitation energies significantly. A different set of parameters, which are optimized for DFTB3, slightly improves the prediction of adiabatic excitation energies statistically. The application of TD-DFTB for the prediction of absorption and fluorescence energies of cresyl violet demonstrates that TD-DFTB3 reproduced the experimental fluorescence energy quite well.

  7. Sediment Curve Uncertainty Estimation Using GLUE and Bootstrap Methods

    Directory of Open Access Journals (Sweden)

    aboalhasan fathabadi

    2017-02-01

    3000 times. Sediment rating curves equation was fitted to each sampled suspended sediment and discharge data sets. Using these sediment rating curve and their residual suspended sediment concentration were calculate for test data. Finally using the 2.5 and 97.5 percentile of the B bootstrap realizations, 95% bootstrap prediction intervals were predicted. Results and Discussion: Results showed that Motorkhane and MiyaneTonelShomare 7 stations were best fitted by a sigmoid function and Stor and Glinak stations were best fitted by second order polynomial and liner function, respectively The first 50 of the B bootstrapped curves were plotted for all stations.with respect to these plots implied that bootstrapped curves more scattered whereas observed data were less. The suspended sediment curve parameters estimated more accurately where, the suspended sediments were sampled more, as a result of reduced uncertainty in estimated suspended sediment concentration due to parameter uncertainty. In addition to sampling density bootstrapped curves, uncertainty depends on the curve shape. For GLUE methodology to assess the impact of threshold values on the uncertainty results, threshold values systematically changed from 0.1 to 0.45. Study results showed that 95% confidence intervals are sensitive to the selected threshold values and higher threshold values will result in an increasing 95% confidence interval. However, the highest 95% confidence intervals obtained by GLUE method (when threshold value was set to 0.1 was little than those values obtained by Bootstrap. Conclusions: The uncertainty of sediment rating curves was addressed in this study by considering two different procedures based on the GLUE and bootstrap methods for four stations in Sefidrod watershed.Results showed that nonlinear equation fitted log-transformed values of sediment concentration and discharge better than linear equation. Uncertainty result using GLUE depend on chosen threshold values. As threshold

  8. Constraining brane tension using rotation curves of galaxies

    Science.gov (United States)

    García-Aspeitia, Miguel A.; Rodríguez-Meza, Mario A.

    2018-04-01

    We present in this work a study of brane theory phenomenology focusing on the brane tension parameter, which is the main observable of the theory. We show the modifications steaming from the presence of branes in the rotation curves of spiral galaxies for three well known dark matter density profiles: Pseudo isothermal, Navarro-Frenk-White and Burkert dark matter density profiles. We estimate the brane tension parameter using a sample of high resolution observed rotation curves of low surface brightness spiral galaxies and a synthetic rotation curve for the three density profiles. Also, the fittings using the brane theory model of the rotation curves are compared with standard Newtonian models. We found that Navarro-Frenk-White model prefers lower values of the brane tension parameter, on the average λ ∼ 0.73 × 10‑3eV4, therefore showing clear brane effects. Burkert case does prefer higher values of the tension parameter, on the average λ ∼ 0.93 eV4 ‑ 46 eV4, i.e., negligible brane effects. Whereas pseudo isothermal is an intermediate case. Due to the low densities found in the galactic medium it is almost impossible to find evidence of the presence of extra dimensions. In this context, we found that our results show weaker bounds to the brane tension values in comparison with other bounds found previously, as the lower value found for dwarf stars composed of a polytropic equation of state, λ ≈ 104 MeV4.

  9. Cognitive deficits after aneurysmal and angiographically negative subarachnoid hemorrhage : Memory, attention, executive functioning, and emotion recognition

    NARCIS (Netherlands)

    Buunk, Anne M; Groen, Rob J M; Veenstra, Wencke S; Metzemaekers, Joannes; van der Hoeven, Johannes H; van Dijk, J Marc C; Spikman, Jacoba M

    2016-01-01

    OBJECTIVE: The authors' aim was to investigate cognitive outcome in patients with aneurysmal and angiographically negative subarachnoid hemorrhage (aSAH and anSAH), by comparing them to healthy controls and to each other. Besides investigating cognitive functions as memory and attention, they

  10. Positional glow curve simulation for thermoluminescent detector (TLD) system design

    International Nuclear Information System (INIS)

    Branch, C.J.; Kearfott, K.J.

    1999-01-01

    Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design

  11. Feynman propagator in curved space-time

    International Nuclear Information System (INIS)

    Candelas, P.; Raine, D.J.

    1977-01-01

    The Wick rotation is generalized in a covariant manner so as to apply to curved manifolds in a way that is independent of the analytic properties of the manifold. This enables us to show that various methods for defining a Feynman propagator to be found in the literature are equivalent where they are applicable. We are also able to discuss the relation between certain regularization methods that have been employed

  12. Semi-empirical master curve concept describing the rate capability of lithium insertion electrodes

    Science.gov (United States)

    Heubner, C.; Seeba, J.; Liebmann, T.; Nickol, A.; Börner, S.; Fritsch, M.; Nikolowski, K.; Wolter, M.; Schneider, M.; Michaelis, A.

    2018-03-01

    A simple semi-empirical master curve concept, describing the rate capability of porous insertion electrodes for lithium-ion batteries, is proposed. The model is based on the evaluation of the time constants of lithium diffusion in the liquid electrolyte and the solid active material. This theoretical approach is successfully verified by comprehensive experimental investigations of the rate capability of a large number of porous insertion electrodes with various active materials and design parameters. It turns out, that the rate capability of all investigated electrodes follows a simple master curve governed by the time constant of the rate limiting process. We demonstrate that the master curve concept can be used to determine optimum design criteria meeting specific requirements in terms of maximum gravimetric capacity for a desired rate capability. The model further reveals practical limits of the electrode design, attesting the empirically well-known and inevitable tradeoff between energy and power density.

  13. Clinical-angiographic correlations in 132 patients with megadolichovertebrobasilar anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Resta, M; Gentile, M A; Di Cuonzo, F; Vinjau, E; Brindicci, D; Carella, A

    1984-05-01

    We have found numerous case reports, but no systematic study of the megadolichovertebrobasilar anomaly (MDVBA). The purpose of this paper is to evaluate the relationships between arterial shifts of the vertebro-basilar system and neurological findings in the posterios fossa in our series of 132 cases. We found a high percentage (77.3%) of angiographic-clinical correlations having evaluated the arterial shifts, measured in mm, of the vertebro basilar system in a frontal and a sagittal plane and concluded that the greater the degree of dislocation, the greater the number of Istituto di Radiologia Universita degli studi of Bari, positive cases. Nevertheless it is not possible to predetermine the presence of particular neurosymptomathology related to arterial dislocation degrees.

  14. Radioembolization with 90Y Microspheres: Angiographic and Technical Considerations

    International Nuclear Information System (INIS)

    Lewandowski, Robert J.; Sato, Kent T.; Atassi, Bassel; Ryu, Robert K.; Nemcek, Albert A.; Kulik, Laura; Geschwind, Jean-Francois; Murthy, Ravi; Rilling, William; Liu, David; Bester, Lourens; Bilbao, Jose Ignacio; Kennedy, Andrew S.; Omary, Reed A.; Salem, Riad

    2007-01-01

    The anatomy of the mesenteric system and the hepatic arterial bed has been demonstrated to have a high degree of variation. This is important when considering pre-surgical planning, catheterization, and trans-arterial hepatic therapies. Although anatomical variants have been well described, the characterization and understanding of regional hepatic perfusion in the context of radioembolization have not been studied with great depth. The purpose of this review is to provide a thorough discussion and detailed presentation of the angiographic and technical aspects of radioembolization. Normal vascular anatomy, commonly encountered variants, and factors involved in changes to regional perfusion in the presence of liver tumors are discussed. Furthermore, the principles described here apply to all liver-directed transarterial therapies

  15. Exactly solvable string models of curved space-time backgrounds

    International Nuclear Information System (INIS)

    Russo, J.G.

    1995-01-01

    We consider a new 3-parameter class of exact 4-dimensional solutions in closed string theory and solve the corresponding string model, determining the physical spectrum and the partition function. The background fields (4-metric, antisymmetric tensor, two Kaluza-Klein vector fields, dilaton and modulus) generically describe axially symmetric stationary rotating (electro)magnetic flux-tube type universes. Backgrounds of this class include both the ''dilatonic'' (a=1) and ''Kaluza-Klein'' (a=√(3)) Melvin solutions and the uniform magnetic field solution, as well as some singular space-times. Solvability of the string σ-model is related to its connection via duality to a simpler model which is a ''twisted'' product of a flat 2-space and a space dual to 2-plane. We discuss some physical properties of this model (tachyonic instabilities in the spectrum, gyromagnetic ratio, issue of singularities, etc.). It provides one of the first examples of a consistent solvable conformal string model with explicit D=4 curved space-time interpretation. (orig.)

  16. A spontaneous pre-anastomotic occlusion does not necessarily impair forearm native dialysis fistulas: echo-Doppler, 3D MR angiographic and digital subtraction angiographic imaging.

    Science.gov (United States)

    Verbeeck, N; Pillet, J C; Prospert, E; McLntyre, D; Lamy, S

    2013-01-01

    Renal transplantation is the choice treatment of end-stage renal disease. When it is not indicated or not immediately feasible, hemodialysis must be performed, preferably via a native arteriovenous fistula in the forearm. A pre-anastomotic occlusion of this type of fistula is often accompanied by a thrombosis of its draining vein. In some instances, the venous segment may remain permeable thanks to the development of arterial collateral pathways and may even allow efficient dialysis without any clinical syndrome of distal steal. We present the echo-Doppler, magnetic and angiographic characteristics of three of these collateralized shunts that have remained functional, in one of the cases following a percutaneous dilation.

  17. Quantitative 4D Transcatheter Intraarterial Perfusion MR Imaging as a Method to Standardize Angiographic Chemoembolization Endpoints

    Science.gov (United States)

    Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.

    2011-01-01

    PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520

  18. Fitness function and nonunique solutions in x-ray reflectivity curve fitting: crosserror between surface roughness and mass density

    International Nuclear Information System (INIS)

    Tiilikainen, J; Bosund, V; Mattila, M; Hakkarainen, T; Sormunen, J; Lipsanen, H

    2007-01-01

    Nonunique solutions of the x-ray reflectivity (XRR) curve fitting problem were studied by modelling layer structures with neural networks and designing a fitness function to handle the nonidealities of measurements. Modelled atomic-layer-deposited aluminium oxide film structures were used in the simulations to calculate XRR curves based on Parratt's formalism. This approach reduced the dimensionality of the parameter space and allowed the use of fitness landscapes in the study of nonunique solutions. Fitness landscapes, where the height in a map represents the fitness value as a function of the process parameters, revealed tracks where the local fitness optima lie. The tracks were projected on the physical parameter space thus allowing the construction of the crosserror equation between weakly determined parameters, i.e. between the mass density and the surface roughness of a layer. The equation gives the minimum error for the other parameters which is a consequence of the nonuniqueness of the solution if noise is present. Furthermore, the existence of a possible unique solution in a certain parameter range was found to be dependent on the layer thickness and the signal-to-noise ratio

  19. Testing MONDian dark matter with galactic rotation curves

    International Nuclear Information System (INIS)

    Edmonds, Doug; Farrah, Duncan; Minic, Djordje; Takeuchi, Tatsu; Ho, Chiu Man; Ng, Y. Jack

    2014-01-01

    MONDian dark matter (MDM) is a new form of dark matter quantum that naturally accounts for Milgrom's scaling, usually associated with modified Newtonian dynamics (MOND), and theoretically behaves like cold dark matter (CDM) at cluster and cosmic scales. In this paper, we provide the first observational test of MDM by fitting rotation curves to a sample of 30 local spiral galaxies (z ≈ 0.003). For comparison, we also fit the galactic rotation curves using MOND and CDM. We find that all three models fit the data well. The rotation curves predicted by MDM and MOND are virtually indistinguishable over the range of observed radii (∼1 to 30 kpc). The best-fit MDM and CDM density profiles are compared. We also compare with MDM the dark matter density profiles arising from MOND if Milgrom's formula is interpreted as Newtonian gravity with an extra source term instead of as a modification of inertia. We find that discrepancies between MDM and MOND will occur near the center of a typical spiral galaxy. In these regions, instead of continuing to rise sharply, the MDM mass density turns over and drops as we approach the center of the galaxy. Our results show that MDM, which restricts the nature of the dark matter quantum by accounting for Milgrom's scaling, accurately reproduces observed rotation curves.

  20. A novel technique for real-time estimation of edge pedestal density gradients via reflectometer time delay data

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, L., E-mail: zeng@fusion.gat.com; Doyle, E. J.; Rhodes, T. L.; Wang, G.; Sung, C.; Peebles, W. A. [Physics and Astronomy Department, University of California, Los Angeles, California 90095 (United States); Bobrek, M. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6006 (United States)

    2016-11-15

    A new model-based technique for fast estimation of the pedestal electron density gradient has been developed. The technique uses ordinary mode polarization profile reflectometer time delay data and does not require direct profile inversion. Because of its simple data processing, the technique can be readily implemented via a Field-Programmable Gate Array, so as to provide a real-time density gradient estimate, suitable for use in plasma control systems such as envisioned for ITER, and possibly for DIII-D and Experimental Advanced Superconducting Tokamak. The method is based on a simple edge plasma model with a linear pedestal density gradient and low scrape-off-layer density. By measuring reflectometer time delays for three adjacent frequencies, the pedestal density gradient can be estimated analytically via the new approach. Using existing DIII-D profile reflectometer data, the estimated density gradients obtained from the new technique are found to be in good agreement with the actual density gradients for a number of dynamic DIII-D plasma conditions.

  1. Similarity recognition of online data curves based on dynamic spatial time warping for the estimation of lithium-ion battery capacity

    Science.gov (United States)

    Tao, Laifa; Lu, Chen; Noktehdan, Azadeh

    2015-10-01

    Battery capacity estimation is a significant recent challenge given the complex physical and chemical processes that occur within batteries and the restrictions on the accessibility of capacity degradation data. In this study, we describe an approach called dynamic spatial time warping, which is used to determine the similarities of two arbitrary curves. Unlike classical dynamic time warping methods, this approach can maintain the invariance of curve similarity to the rotations and translations of curves, which is vital in curve similarity search. Moreover, it utilizes the online charging or discharging data that are easily collected and do not require special assumptions. The accuracy of this approach is verified using NASA battery datasets. Results suggest that the proposed approach provides a highly accurate means of estimating battery capacity at less time cost than traditional dynamic time warping methods do for different individuals and under various operating conditions.

  2. Angiographic differentiation of the forms of truncus arteriosis communis and their prognostic significance

    International Nuclear Information System (INIS)

    Schumacher, G.; Schreiber, R.; Lorenz, H.P.; Sebening, W.; Meisner, H.; Sebening, F.; Buehlmeyer, K.; Deutsches Herzzentrum Muenchen des Freistaates Bayern

    1986-01-01

    To decisively improve the life expectancy of children having a truncus arteriosus communis, early surgical intervention during the first year is necessary. As a prerequisite for a successful intervention, a precise diagnosis must be made including angiographic differentiation of the form of the truncus arteriosus communis and possible associated cardiovascular malformations must be established; these constitute important operation hazards and can determine the ultimate success of the intervention. (orig.) [de

  3. Minimum entropy density method for the time series analysis

    Science.gov (United States)

    Lee, Jeong Won; Park, Joongwoo Brian; Jo, Hang-Hyun; Yang, Jae-Suk; Moon, Hie-Tae

    2009-01-01

    The entropy density is an intuitive and powerful concept to study the complicated nonlinear processes derived from physical systems. We develop the minimum entropy density method (MEDM) to detect the structure scale of a given time series, which is defined as the scale in which the uncertainty is minimized, hence the pattern is revealed most. The MEDM is applied to the financial time series of Standard and Poor’s 500 index from February 1983 to April 2006. Then the temporal behavior of structure scale is obtained and analyzed in relation to the information delivery time and efficient market hypothesis.

  4. Angiographic diagnosis of the prehepatic portal hypertension

    International Nuclear Information System (INIS)

    Carnevali, G.; Brambilla, G.

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases, in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results. (orig./MG) [de

  5. Angiographic diagnosis of the prehepatic portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Carnevali, G; Brambilla, G

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases and in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results.

  6. The angiographic demonstration of hepatic vein obstruction

    International Nuclear Information System (INIS)

    Zu Maoheng; Xu Hao; Li Guojun; Gu Yuming; Wei Ning; Wang Cheng; Xu Wei

    2004-01-01

    Objective: To evaluate the angiographic feature of hepatic vein obstruction. Methods Forty-five patients (male 23, female 22, age 9-54 years) suffered from hepatic vein obstruction. The inferior vena cavography and the hepatic venography were performed in all cases. Results: IVC was free in 37 patients with hepatic vein obstruction, both IVC and HV were obstructed in 8 patients. The local or long stenosis of IVC was found in 31 inferior vena cavography. The diameter of IVC was normal in 12 patients. The sign of membranous dome was found in hepatic vein orifice in 5 cases and in accessory hepatic vein orifice in 4 cases. Intrahepatic venous collaterals were found in 45 cases. Conclusion: Hepatic vein obstruction can be reproached primarily in inferior vena cavography, the membranous dome is a direct sign of membranous obstruction of HV and AHV in inferior vena cavography. The selected hepatic venography can provide reliable evidence to diagnose hepatic vein obstruction

  7. Lipoprotein subclasses in the Monitored Atherosclerosis Regression Study (MARS). Treatment effects and relation to coronary angiographic progression.

    Science.gov (United States)

    Mack, W J; Krauss, R M; Hodis, H N

    1996-05-01

    Accumulating evidence suggests that triglyceride-rich lipoproteins contribute to coronary artery disease. Using data from the Monitored Atherosclerosis Regression Study, an angiographic trial of middle-aged men and women randomized to lovastatin or placebo, we investigated relationships between lipoprotein subclasses and progression of coronary artery atherosclerosis. Coronary artery lesion progression was determined by quantitative coronary angiography in low-grade ( or = 50% diameter stenosis), and all coronary artery lesions in 220 baseline/2-year angiogram pairs. Analytical ultracentrifugation was used to measure lipoprotein masses that were statistically evaluated for treatment group differences and relationships to progression of coronary artery atherosclerosis. All low density lipoprotein (LDL), intermediate density lipoprotein (IDL), and very low density lipoprotein (VLDL) masses were significantly lowered and all high density lipoprotein (HDL) masses were significantly raised with lovastatin therapy. The mass of smallest LDL (Svedberg flotation rate [Sf] 0 to 3), IDL (Sf 12 to 20), all VLDL subclasses (Sf 20 to 60, Sf 60 to 100, and Sf 100 to 400), and peak LDL flotation rate were significantly related to the progression of coronary artery lesions, specifically low-grade lesions. Greater baseline levels of HDL3, were related to a lower likelihood of coronary artery lesion progression. In multivariate analyses, small VLDL (Sf 20 to 60) and HDL3 mass were the most important correlates of coronary artery lesion progression. These results provide further evidence for the importance of triglyceride-rich lipoproteins in the progression of coronary artery disease. In addition, these results present new evidence for the possible protective role of HDL3 in the progression of coronary artery lesions. More specific information on coronary artery lesion progression may be obtained through the study of specific apolipoprotein B-containing lipoproteins.

  8. Study of the Vapor-Liquid Coexistence Curve and the Critical Curve for Nonazeotropic Refrigerant Mixture R152a + R114 System

    Science.gov (United States)

    Kabata, Yasuo; Higashi, Yukihiro; Uematsu, Masahiko; Watanabe, Koichi

    Measurements of the vapor-liquid coexistence curve in the critical region for the refrigerant mixture of R152a (CH3CHF2: 1, l-difluoroethane) +R 114 (CCIF2CCIF2 :1, 2-dichloro-1, 1, 2, 2-tetrafluoroethane) system were made by visual observation of the disappearance of the meniscus at the vapor-liquid interface within an optical cell. Forty-eight saturated densities along the vapor-liquid coexistence curve between 204 and 861 kg·m-3 for five different compositions of 10, 20, 50, 80 and 90 wt% R 152a were obtained in the temperature range 370 to 409 K. The experimental errors of temperature, density, and mass fraction were estimated within ±10mK, ±0.5% and +0.05 %, respectively. On the basis of these measurements, the critical parameters of five different compositions for the R 152a +R 114 system were determined in consideration of the meniscus disappearance level as well as intensity of the critical opalescence. In accordance with the previous results of three other refrigerant mixtures, i.e., R 12 +R 22 system, R 22 +R 114 system and R 13B1 + R 114 system, the coexistence curve and critical curve on the temperature-density diagram for binary refrigerant mixtures were discussed. In addition, correlations of its composition dependence for this system were proposed.

  9. Renormalization of non-abelian gauge theories in curved space-time

    International Nuclear Information System (INIS)

    Freeman, M.D.

    1984-01-01

    We use indirect, renormalization group arguments to calculate the gravitational counterterms needed to renormalize an interacting non-abelian gauge theory in curved space-time. This method makes it straightforward to calculate terms in the trace anomaly which first appear at high order in the coupling constant, some of which would need a 4-loop calculation to find directly. The role of gauge invariance in the theory is considered, and we discuss briefly the effect of using coordinate-dependent gauge-fixing terms. We conclude by suggesting possible applications of this work to models of the very early universe

  10. Sagittal curve and high metal density in adolescent idiopathic scoliosis

    Directory of Open Access Journals (Sweden)

    Fabio Araújo Fernandes

    2014-01-01

    Full Text Available Objectives: To analyze radiographically the postoperative kyphosis from patients undergoing surgical treatment for AIS with pedicle screws in all vertebrae included in the arthrodesis. Methods: Retrospective study. The following measurements were evaluated: Cobb angle in anteroposterior radiograph of the three curves (proximal thoracic, main thoracic, and lumbar, Cobb angle in the lateral view of the two curves: thoracic kyphosis (T5-T12 and lumbar lordosis (T12-S1. Results: Of the 25 patients evaluated preoperatively, four (16% were hypokyphotic, 20 patients (80% were normokyphotic and only one (4% was hyperkyphotic. For hypokyphotic and hiperkyphotic patients a satisfactory correction of thoracic kyphosis was obtained in 100% of cases, which was preserved in the final result. The same pattern of thoracic kyphosis was observed for all normokyphotic patients throughout the follow-up. Conclusion: Radiographic evaluation of thoracic kyphosis in patients with AIS treated surgically with pedicle screws in all vertebrae showed satisfactory results with respect to the correction of thoracic kyphosis.

  11. Correlation between use time of machine and decline curve for emerging enterprise information systems

    Science.gov (United States)

    Chang, Yao-Chung; Lai, Chin-Feng; Chuang, Chi-Cheng; Hou, Cheng-Yu

    2018-04-01

    With the progress of science and technology, more and more machines are adpot to help human life better and more convenient. When the machines have been used for a longer period of time so that the machine components are getting old, the amount of power comsumption will increase and easily cause the machine to overheat. This also causes a waste of invisible resources. If the Internet of Everything (IoE) technologies are able to be applied into the enterprise information systems for monitoring the machines use time, it can not only make energy can be effectively used, but aslo create a safer living environment. To solve the above problem, the correlation predict model is established to collect the data of power consumption converted into power eigenvalues. This study takes the power eigenvalue as the independent variable and use time as the dependent variable in order to establish the decline curve. Ultimately, the scoring and estimation modules are employed to seek the best power eigenvalue as the independent variable. To predict use time, the correlation is discussed between the use time and the decline curve to improve the entire behavioural analysis of the facilitate recognition of the use time of machines.

  12. Angiographic manifestation and transcatheter arterial embolization of proper esophageal artery in hemoptysis

    International Nuclear Information System (INIS)

    Jiang Sen; Zhu Xiaohua; Sun Xiwen; Zhi Wenxiang; Jie Bing; You Zhengqian; Yu Dong; Peng Gang

    2008-01-01

    Objective: To investigate the angiographic manifestation of the proper esophageal artery (PEA), the high risk factors for the presence of the anomalous PEA in hemoptysis and to evaluate the safety of transcatheter arterial embolization (TAE) of the PEA using gelatin sponge (GS). Methods: Selective esophageal arteriography was performed in forty-three patients with hemoptysis, including 15 cases of pulmonary tuberculosis, 18 cases of bronchiectasis, 7 cases of posttuberculous bronchiectasis and three cases of lung cancer. One case experienced failure of bronchial arterial embolization. The angiographic manifestation of the PEAs was studied. The complications of the procedure and clinical results were observed in the patients who underwent TAE using GS. Results: Thirty-nine PEAs were catheterized selectively in 37 patients (86.0%). Eighteen anomalous PEAs (46.2%) were catheterized selectively in 17 patients (45.9%). The anomalous PEAs showed tortuosity, dilatation, hyperplasia, shunting with pulmonary artery and anastomosis with the bronchial artery. All lesions involved basal segment of inferior pulmonary lobar. Bronchiectasis was the most frequent disease for PEA abnormality. No complications occurred and satisfactory curative effect was achieved with TAE of the anomalous PEAs. Conclusions: It is necessary to perform selective proper esophageal arteriography when the lesion involves basal segment of inferior pulmonary lobar in hemoptysis. Supplemental TAE of the anomalous PEA using GS is safe and valuable in the management of hemoptysis. (authors)

  13. Limited sampling strategy for determining metformin area under the plasma concentration-time curve

    DEFF Research Database (Denmark)

    Santoro, Ana Beatriz; Stage, Tore Bjerregaard; Struchiner, Claudio José

    2016-01-01

    AIM: The aim was to develop and validate limited sampling strategy (LSS) models to predict the area under the plasma concentration-time curve (AUC) for metformin. METHODS: Metformin plasma concentrations (n = 627) at 0-24 h after a single 500 mg dose were used for LSS development, based on all su...

  14. Clinical presentations and MRI findings of angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Oyama, Hirofumi; Iwakoshi, Takayasu

    1994-01-01

    Various clinical features as well as MRI findings of AOVM (angiographically occult vascular malformation) were studied. Amongst out patients, since January 1988, there have been 30 cases of symptomatic AOVM (20 males, 10 females) including 4 cases with multiple lesions. The age ranged from 3 to 60 years of age, with a mean of 33.4 years. The locations of symptomatic lesions were in the cerebral hemisphere (15), the thalamus (4), the brain stem (8) and in the cerebellum (3). The initial presentations of these 30 cases were either by hemorrhage (18), convulsive seizure (9) or by progressive neurological deficits (3). The initial presentation was not related to the patient's age and the size of the lesion, but apparently related to the location of AOVM. Most of the lesions in the cerebral hemisphere presented seizures, but all of the lesions in the thalamus, the brain stem and the cerebellum disclosed hemorrhage as an initial presentation. In fact it was noticed that brain stem lesions tend to cause repetitive hemorrhage in a relatively short period. AOVM lesions were clearly visualized with T2-weighted MRI images, consisting of high intensity cores with surrounding low intensity rims. Most of the symptomatic lesions were partially enhanced by Gd-DTPA with varied intensity. Dynamic changes in size and enhancement pattern on MRI were occasionally seen, usually accompanied with episodes such as hemorrhage or neurological deterioration. Although AOVMs were angiographically negative some strands indicating draining veins were observed on MRI in several cases. In contrast, none of the nonsymptomatic lesions (22 lesions) demonstrated enhancement effects with Gd-DTPA. (author)

  15. The method of covariant symbols in curved space-time

    International Nuclear Information System (INIS)

    Salcedo, L.L.

    2007-01-01

    Diagonal matrix elements of pseudodifferential operators are needed in order to compute effective Lagrangians and currents. For this purpose the method of symbols is often used, which however lacks manifest covariance. In this work the method of covariant symbols, introduced by Pletnev and Banin, is extended to curved space-time with arbitrary gauge and coordinate connections. For the Riemannian connection we compute the covariant symbols corresponding to external fields, the covariant derivative and the Laplacian, to fourth order in a covariant derivative expansion. This allows one to obtain the covariant symbol of general operators to the same order. The procedure is illustrated by computing the diagonal matrix element of a nontrivial operator to second order. Applications of the method are discussed. (orig.)

  16. Divergence identities in curved space-time. A resolution of the stress-energy problem

    International Nuclear Information System (INIS)

    Yilmaz, H.; Tufts Univ., Medford, MA

    1989-01-01

    It is noted that the joint use of two basic differential identities in curved space-time, namely. 1) the Einstein-Hilbert identity (1915), and 2) the identity of P. Freud (1939), permits a viable alternative to general relativity and a resolution of the field stress-energy' problem of the gravitational theory. (orig.)

  17. Wind Turbine Power Curves Incorporating Turbulence Intensity

    DEFF Research Database (Denmark)

    Sørensen, Emil Hedevang Lohse

    2014-01-01

    . The model and method are parsimonious in the sense that only a single function (the zero-turbulence power curve) and a single auxiliary parameter (the equivalent turbulence factor) are needed to predict the mean power at any desired turbulence intensity. The method requires only ten minute statistics......The performance of a wind turbine in terms of power production (the power curve) is important to the wind energy industry. The current IEC-61400-12-1 standard for power curve evaluation recognizes only the mean wind speed at hub height and the air density as relevant to the power production...

  18. Unexpected storm-time nightside plasmaspheric density enhancement at low L shell

    Science.gov (United States)

    Chu, X.; Bortnik, J.; Denton, R. E.; Yue, C.

    2017-12-01

    We have developed a three-dimensional dynamic electron density (DEN3D) model in the inner magnetosphere using a neural network approach. The DEN3D model can provide spatiotemporal distribution of the electron density at any location and time that spacecraft observations are not available. Given DEN3D's good performance in predicting the structure and dynamic evolution of the plasma density, the salient features of the DEN3D model can be used to gain further insight into the physics. For instance, the DEN3D models can be used to find unusual phenomena that are difficult to detect in observations or simulations. We report, for the first time, an unexpected plasmaspheric density increase at low L shell regions on the nightside during the main phase of a moderate storm during 12-16 October 2004, as opposed to the expected density decrease due to storm-time plasmaspheric erosion. The unexpected density increase is first discovered in the modeled electron density distribution using the DEN3D model, and then validated using in-situ density measurements obtained from the IMAGE satellite. The density increase was likely caused by increased earthward transverse field plasma transport due to enhanced nightside ExB drift, which coincided with enhanced solar wind electric field and substorm activity. This is consistent with the results of physics-based simulation SAMI3 model which show earthward enhanced plasma transport and electron density increase at low L shells during storm main phase.

  19. Control-oriented modeling of the plasma particle density in tokamaks and application to real-time density profile reconstruction

    NARCIS (Netherlands)

    Blanken, T.C.; Felici, F.; Rapson, C.J.; de Baar, M.R.; Heemels, W.P.M.H.

    2018-01-01

    A model-based approach to real-time reconstruction of the particle density profile in tokamak plasmas is presented, based on a dynamic state estimator. Traditionally, the density profile is reconstructed in real-time by solving an ill-conditioned inversion problem using a measurement at a single

  20. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care; Wirtschaftliche Evaluation angiographischer Interventionen einschliesslich einer radiologischen stationaeren und ambulanten Patientenbetreuung

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  1. Power Curve Estimation With Multivariate Environmental Factors for Inland and Offshore Wind Farms

    KAUST Repository

    Lee, Giwhyun

    2015-04-22

    In the wind industry, a power curve refers to the functional relationship between the power output generated by a wind turbine and the wind speed at the time of power generation. Power curves are used in practice for a number of important tasks including predicting wind power production and assessing a turbine’s energy production efficiency. Nevertheless, actual wind power data indicate that the power output is affected by more than just wind speed. Several other environmental factors, such as wind direction, air density, humidity, turbulence intensity, and wind shears, have potential impact. Yet, in industry practice, as well as in the literature, current power curve models primarily consider wind speed and, sometimes, wind speed and direction. We propose an additive multivariate kernel method that can include the aforementioned environmental factors as a new power curve model. Our model provides, conditional on a given environmental condition, both the point estimation and density estimation of power output. It is able to capture the nonlinear relationships between environmental factors and the wind power output, as well as the high-order interaction effects among some of the environmental factors. Using operational data associated with four turbines in an inland wind farm and two turbines in an offshore wind farm, we demonstrate the improvement achieved by our kernel method.

  2. An integral parametrization of the bacterial growth curve experimental demonstration with E. coli C600 bacteria

    International Nuclear Information System (INIS)

    Garces, F.; Vidania, R. de

    1984-01-01

    In this work an integral parametrization of the bacterial growth curve is presented. The values of the parameters are obtained by fitting to the experimental data. Those parameters, with allow to describe the growth in its different phases, are the followings: slopes of the curve in its three parts and the time which divides the last two phases of the bacterial growth. The experimental data are bacterial densities measured by optical methods. The bacteria used was the E. coli C 6 00. (Author)

  3. Time-dependent density functional theory for multi-component systems

    International Nuclear Information System (INIS)

    Tiecheng Li; Peiqing Tong

    1985-10-01

    The Runge-Gross version of Hohenberg-Kohn-Sham's density functional theory is generalized to multi-component systems, both for arbitrary time-dependent pure states and for arbitrary time-dependent ensembles. (author)

  4. Dirac equation in 5- and 6-dimensional curved space-time manifolds

    International Nuclear Information System (INIS)

    Vladimirov, Yu.S.; Popov, A.D.

    1984-01-01

    The program of plotting unified multidimensional theory of gravitation, electromagnetism and electrically charged matter with transition from 5-dimensional variants to 6-dimensional theory possessing signature (+----+) is developed. For recording the Dirac equation in 5- and 6-dimensional curved space-time manifolds the tetrad formalism and γ-matrix formulation of the General Relativity Theory are used. It is shown that the 6-dimensional theory case unifies the two private cases of 5-dimensional theory and corresponds to two possibilities of the theory developed by Kadyshevski

  5. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  6. Vaporization of comet nuclei: Light curves and life times

    Energy Technology Data Exchange (ETDEWEB)

    Cowan, J J [Harvard Univ., Cambridge, MA (USA). Center for Astrophysics; A' Hearn, M F [Maryland Univ., College Park (USA)

    1979-10-01

    The authors have examined the effects of vaporization from the nucleus of a comet and show that a latitude dependence of vaporization can, in some cases, explain asymmetries in commetary light curves. They also find that a non-uniform distribution of solar radiation over a comet can considerably shorten the vaporization lifetime compared to the results normally obtained by assuming that the nuclear surface is isothermal. Independent of any latitude effects, comets with CO/sub 2/-dominated nuclei and with periherlion distances less than 0.5 AU have vaporization lifetimes less than or comparable to their dynamical ejection times. This may explain the observed deficit of comets with small perihelion distances. Similarly comets with CO/sub 2/-dominated nuclei and perihelia near Jupiter's orbit have vaporization lifetimes that are shorter than the time for capture into short-period orbits. They suggest, therefore, that at least some new comets are composed in large part of CO/sub 2/, while only H/sub 2/O-dominated comets, with lower vaporization rates, can survive to be captured into short-period orbits.

  7. Angiographic Characteristics of Symptomatic Recurrent Disease After Infrainguinal Percutaneous Transluminal Angioplasty

    International Nuclear Information System (INIS)

    Soeder, Heini K.; Manninen, Hannu I.; Matsi, Pekka J.

    1999-01-01

    Purpose: To evaluate the angiographic patterns of clinically manifest recurrent disease after infrainguinal percutaneous transluminal angioplasty (PTA) of stenoses and total occlusions. Methods: Among 326 infrainguinal PTAs on 263 consecutive patients, selective angiography was performed on 61 limbs of 52 patients 1-60 months after the primary intervention because of clinically suspected recurrent disease. Lesion-specific and patient-related factors were analyzed for 75 angiographically confirmed recurrent lesions in 57 limbs of 48 patients. Results: Recurrent disease was more frequently a stenosis when the original target lesion was a stenosis (92%, 44/48) than when the original lesion was a total occlusion (59%, 16/27; p < 0.001). When the original target lesion was a stenosis, the total length of the recurrent disease was longer than that of the original lesion [3.9 ± 3.9 cm (mean ± standard deviation) vs 2.8 ± 2.7 cm; p= 0.03], while in the subgroup of original total occlusions the length of the recurrent lesion was shorter than that of the original occlusion (7.1 ± 5.0 cm vs 9.9 ± 6.9 cm; p0.02). Half the restenoses (22/44) extended beyond one or both ends of the original stenosis and 38% (6/16) of the reocclusions extended beyond the distal end of the original occlusion. Conclusions: The type of recurrent disease depends on the original lesion type and the restenotic lesion frequently extends beyond one or both ends of the original target lesion

  8. The Hadamard construction of Green's functions on a curved space-time: physics and explicit rigorous results

    International Nuclear Information System (INIS)

    John, R.W.

    1987-01-01

    First, in connection with their construction due to Hadamard, the mathematical and physical meaning of covariant Green's functions in relativistic gravitational fields - according to Einstein: on curved space-time - is discussed. Then, in the case of a general static spherically symmetric space-time the construction equations for a scalar Green's function are cast into symmetry-adapted form providing a convenient starting point for an explicit calculation of the Hadamard building elements. In applying the obtained basic scheme to a special one-parameter family of model metrics one succeeds in advancing to the explicit exact calculation of tail-term coefficients of a massless Green's function which are simultaneously coefficients in the Schwinger-De Witt expansion of the Feynman propagator for the corresponding massive Klein-Gordon equation on curved space-time. (author)

  9. Relationship of myocardial hibernation, scar, and angiographic collateral flow in ischemic cardiomyopathy with coronary chronic total occlusion.

    Science.gov (United States)

    Wang, Li; Lu, Min-Jie; Feng, Lei; Wang, Juan; Fang, Wei; He, Zuo-Xiang; Dou, Ke-Fei; Zhao, Shi-Hua; Yang, Min-Fu

    2018-03-07

    The relationship between myocardial viability and angiographic collateral flow is not fully elucidated in ischemic cardiomyopathy (ICM) with coronary artery chronic total occlusion (CTO). We aimed to clarify the relationship between myocardial hibernation, myocardial scar, and angiographic collateral flow in these patients. Seventy-one consecutive ICM patients with 122 CTOs and 652 dysfunctional segments within CTO territories were retrospectively analyzed. Myocardial hibernation (perfusion-metabolism mismatch) and the extent of 18 F-fluorodeoxyglucose (FDG) abnormalities were assessed using 99m Tc-sestamibi and 18 F-FDG imaging. Myocardial scar was evaluated by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. Collateral flow observed on coronary angiography was assessed using Rentrop classification. In these patients, neither the extent nor frequency of myocardial hibernation or scar was related to the status of collateral flow. Moreover, the matching rate in determining myocardial viability was poor between any 2 imaging indices. The extent of 18 F-FDG abnormalities was linearly related to the extent of LGE rather than myocardial hibernation. Of note, nearly one-third (30.4%) of segments with transmural scar still had hibernating tissue. Hibernation and non-transmural scar had higher sensitivity (63.0% and 66.7%) than collateral flow (37.0%) in predicting global functional improvement. Angiographic collateral cannot accurately predict myocardial viability, and has lower sensitivity in prediction of functional improvement in CTO territories in ICM patients. Hence, assessment of myocardial viability with non-invasive imaging modalities is of importance. Moreover, due to the lack of correlation between myocardial hibernation and scar, these two indices are complementary but not interchangeable.

  10. IGBT Switching Characteristic Curve Embedded Half-Bridge MMC Modelling and Real Time Simulation Realization

    Science.gov (United States)

    Zhengang, Lu; Hongyang, Yu; Xi, Yang

    2017-05-01

    The Modular Multilevel Converter (MMC) is one of the most attractive topologies in recent years for medium or high voltage industrial applications, such as high voltage dc transmission (HVDC) and medium voltage varying speed motor drive. The wide adoption of MMCs in industry is mainly due to its flexible expandability, transformer-less configuration, common dc bus, high reliability from redundancy, and so on. But, when the sub module number of MMC is more, the test of MMC controller will cost more time and effort. Hardware in the loop test based on real time simulator will save a lot of time and money caused by the MMC test. And due to the flexible of HIL, it becomes more and more popular in the industry area. The MMC modelling method remains an important issue for the MMC HIL test. Specifically, the VSC model should realistically reflect the nonlinear device switching characteristics, switching and conduction losses, tailing current, and diode reverse recovery behaviour of a realistic converter. In this paper, an IGBT switching characteristic curve embedded half-bridge MMC modelling method is proposed. This method is based on the switching curve referring and sample circuit calculation, and it is sample for implementation. Based on the proposed method, a FPGA real time simulation is carried out with 200ns sample time. The real time simulation results show the proposed method is correct.

  11. The X-ray Power Density Spectrum of the Seyfert 2 Galaxy NGC 4945: Analysis and Application of the Method of Light Curve Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Martin; /SLAC

    2010-12-16

    The study of the power density spectrum (PDS) of fluctuations in the X-ray flux from active galactic nuclei (AGN) complements spectral studies in giving us a view into the processes operating in accreting compact objects. An important line of investigation is the comparison of the PDS from AGN with those from galactic black hole binaries; a related area of focus is the scaling relation between time scales for the variability and the black hole mass. The PDS of AGN is traditionally modeled using segments of power laws joined together at so-called break frequencies; associations of the break time scales, i.e., the inverses of the break frequencies, with time scales of physical processes thought to operate in these sources are then sought. I analyze the Method of Light Curve Simulations that is commonly used to characterize the PDS in AGN with a view to making the method as sensitive as possible to the shape of the PDS. I identify several weaknesses in the current implementation of the method and propose alternatives that can substitute for some of the key steps in the method. I focus on the complications introduced by uneven sampling in the light curve, the development of a fit statistic that is better matched to the distributions of power in the PDS, and the statistical evaluation of the fit between the observed data and the model for the PDS. Using archival data on one AGN, NGC 3516, I validate my changes against previously reported results. I also report new results on the PDS in NGC 4945, a Seyfert 2 galaxy with a well-determined black hole mass. This source provides an opportunity to investigate whether the PDS of Seyfert 1 and Seyfert 2 galaxies differ. It is also an attractive object for placement on the black hole mass-break time scale relation. Unfortunately, with the available data on NGC 4945, significant uncertainties on the break frequency in its PDS remain.

  12. Effects of time-temperature profiles on glow curves of germanium-doped optical fibre

    Science.gov (United States)

    Lam, S. E.; Alawiah, A.; Bradley, D. A.; Mohd Noor, N.

    2017-08-01

    The Germanium (Ge) doped silica optical fibres have demonstrated the great potential to be developed as a thermoluminescent (TL) dosimeter that can be used in various applications in radiotherapy, diagnostic radiology, UV dosimetry system and food irradiation industry. Different time-temperature profile (TTP) parameters of the TL reader have been employed by many researchers in various of TL studies. Nevertheless, none of those studies adequately addressed the effects of the reader's preheat temperature and heating rate on the kinetic parameters of the TL glow curve specifically, the Ge-doped silica optical fibres. This research addresses the issue of TTP parameters with special attention to the determination of the kinetic parameters of the glow curve. The glow curve responses were explored and the kinetic parameters were analyzed by the WinGCF software, to show the effect of the preheat temperature and heating rate of the reader on Ge-doped fibre irradiated with 18 Gy of 6 MV photons radiation. The effect of TTP parameters was discussed and compared against the commercial fibre and tailored made fibre of 6 mol% Ge-doped of flat and cylindrical shape. The deconvolution of glow peaks and the kinetic parameters were obtained by the WinGCF software. This enables to fit accurately (1.5%curves. A positive, moderate linear relationship exists between the TL response and the heating rate when the specific preheat temperature was used to read commercial fibre (50 °C) and cylindrical fibre (80 °C and 160 °C). It is found that the glow peaks of cylindrical fibre exhibit the highest peak integral as compared to flat and commercial fibres. This study revealed the possible relationship between the reader's TTP parameters and the kinetic parameters of TL glow curves for the commercial and tailored made Ge-doped silica optical fibres.

  13. Real-time electron density measurements from Cotton-Mouton effect in JET machine

    International Nuclear Information System (INIS)

    Brombin, M.; Boboc, A.; Zabeo, L.; Murari, A.

    2008-01-01

    Real-time density profile measurements are essential for advanced fusion tokamak operation and interferometry is a proven method for this task. Nevertheless, as a consequence of edge localized modes, pellet injections, fast density increases, or disruptions, the interferometer is subject to fringe jumps, which produce loss of the signal preventing reliable use of the measured density in a real-time feedback controller. An alternative method to measure the density is polarimetry based on the Cotton-Mouton effect, which is proportional to the line-integrated electron density. A new analysis approach has been implemented and tested to verify the reliability of the Cotton-Mouton measurements for a wide range of plasma parameters and to compare the density evaluated from polarimetry with that from interferometry. The density measurements based on polarimetry are going to be integrated in the real-time control system of JET since the difference with the interferometry is within one fringe for more than 90% of the cases.

  14. Unilateral renal agenesia in the angiographic material and renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Stojanov, D.; Lovasic, I.; Dujmovic, M.; Bobinac, D.

    1987-06-01

    Analysis of 1216 abdominal aortographies and selective renovasographies undertaken at the Institute of Radiology, Clinical Hospital Centre Rijeka during the period 1979-1985, was performed. 39 (3,2%) unilateral renal agenesias were established, a percentage that is significantly higher than reported by other authors. Analysis of all angiographic parameters of a single kidney was also worked out. A significanlty high percentage (66,7%) of hypertension was diagnosed in this group. Congenital renal failures make their appearance in the early embryological development and are discovered, if compatible with life, most frequently at an advanced age. Statistical data on the frequency during a lifetime are less reliable because a great number of anomalies are never discovered during a person's life. The etiology of variations and congenital failure of renal arteries is unknown in 90% of the cases, and most of the malformations are without characteristic symptomatology. Since the anatomic relations in anomalous kidney are disturbed, the sign of the disease can develop atypical forms causing frequent errors in diagnosis. The kidney is supplied by numerous lateral branches of the medial sacral artery, i.e. the aorta, during embryological development. Later, some of them degenerate or mutually connect themselves, and the definitive kidney has been usually penetrated by only one artery and one vein on the same side (1). If this is not so, i.e. when the obliterations of caudal metanephogenic arteries are only partially present, then the renal arteries emerge from the iliac or lumbar arteries (2,3). Bilateral renal agenesia is extreme and incompatible with life, and hence of small clinical importance. Unilateral agenesia makes its appearance according to various statistics and authors from the obductional materials in ratio 1:1000 (4,5), clinical ones 1:5000 (6, 7, 8) and the angiographically 1:76(9), more exactly 1:35 cases (10).

  15. Unilateral renal agenesia in the angiographic material and renovascular hypertension

    International Nuclear Information System (INIS)

    Stojanov, D.; Lovasic, I.; Dujmovic, M.; Bobinac, D.

    1987-01-01

    Analysis of 1216 abdominal aortographies and selective renovasographies undertaken at the Institute of Radiology, Clinical Hospital Centre Rijeka during the period 1979-1985, was performed. 39 (3,2%) unilateral renal agenesias were established, a percentage that is significantly higher than reported by other authors. Analysis of all angiographic parameters of a single kidney was also worked out. A significanlty high percentage (66,7%) of hypertension was diagnosed in this group. Congenital renal failures make their appearance in the early embryological development and are discovered, if compatible with life, most frequently at an advanced age. Statistical data on the frequency during a lifetime are less reliable because a great number of anomalies are never discovered during a person's life. The etiology of variations and congenital failure of renal arteries is unknown in 90% of the cases, and most of the malformations are without characteristic symptomatology. Since the anatomic relations in anomalous kidney are disturbed, the sign of the disease can develop atypical forms causing frequent errors in diagnosis. The kidney is supplied by numerous lateral branches of the medial sacral artery, i.e. the aorta, during embryological development. Later, some of them degenerate or mutually connect themselves, and the definitive kidney has been usually penetrated by only one artery and one vein on the same side (1). If this is not so, i.e. when the obliterations of caudal metanephogenic arteries are only partially present, then the renal arteries emerge from the iliac or lumbar arteries (2,3). Bilateral renal agenesia is extreme and incompatible with life, and hence of small clinical importance. Unilateral agenesia makes its appearance according to various statistics and authors from the obductional materials in ratio 1:1000 (4,5), clinical ones 1:5000 (6, 7, 8) and the angiographically 1:76(9), more exactly 1:35 cases (10). (orig.)

  16. Coherent density fluctuation model as a local-scale limit to ATDHF

    International Nuclear Information System (INIS)

    Antonov, A.N.; Petkov, I.Zh.; Stoitsov, M.V.

    1985-04-01

    The local scale transformation method is used for the construction of an Adiabatic Time-Dependent Hartree-Fock approach in terms of the local density distribution. The coherent density fluctuation relations of the model result in a particular case when the ''flucton'' local density is connected with the plane wave determinant model function be means of the local-scale coordinate transformation. The collective potential energy expression is obtained and its relation to the nuclear matter energy saturation curve is revealed. (author)

  17. Pattern not volume of bleeding predicts angiographic vasospasm in nonaneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Raya, Amanda; Zipfel, Gregory J; Diringer, Michael N; Dacey, Ralph G; Derdeyn, Colin P; Rich, Keith M; Chicoine, Michael R; Dhar, Rajat

    2014-01-01

    Spontaneous idiopathic subarachnoid hemorrhage (SAH) with a perimesencephalic bleeding pattern is usually associated with a benign course, whereas a diffuse bleeding pattern has been associated with a higher risk of vasospasm and disability. We evaluated whether volume of bleeding explains this disparity. Pattern and amount of bleeding (by Hijdra and intraventricular hemorrhage scores) were assessed in 89 patients with nonaneurysmal SAH. Outcomes included angiographic vasospasm, delayed cerebral ischemia, and functional outcome at 1 year. Diffuse bleeding was associated with significantly higher Hijdra and intraventricular hemorrhage scores than perimesencephalic SAH, P≤0.003. Angiographic vasospasm was more likely in diffuse versus perimesencephalic SAH (45% versus 27%; odds ratio, 2.9; P=0.08), but adjustment for greater blood burden only partially attenuated this trend (adjusted odds ratio, 2.2; 95% confidence interval, 0.69-7.2; P=0.18); delayed cerebral ischemia was only seen in those with diffuse bleeding. Patients with diffuse bleeding were less likely to be discharged home (68% versus 90%; P=0.01) and tended to have more residual disability (modified Rankin scale, 3-6; 20% versus 6%; P=0.18). Nonaneurysmal SAH can still result in vasospasm and residual disability, especially in those with diffuse bleeding. This disparity is only partially accounted for by greater cisternal or intraventricular blood, suggesting that the mechanism and distribution of bleeding may be as important as the amount of hemorrhage in patients with idiopathic SAH.

  18. ELECTRICAL CONDUCTIVITY OF SOYBEAN SEED CULTIVARS AND ADJUSTED MODELS OF LEAKAGE CURVES ALONG THE TIME

    Directory of Open Access Journals (Sweden)

    ADRIANA RITA SALINAS

    2010-01-01

    Full Text Available The objective of this work was to study the behavior of ten soybean [Glycine max (L. Merr.] cultivars using the electrical conductivity (EC test by the comparison of curves of the accumulative electrolyte leakage along the time and to establish the statistical model that allow the best adjust of the curves. Ten soybean cultivars were used and they were mechanically harvested in 2004 in the EEA Oliveros, Santa Fe, Argentina. Measurements of EC were made for 100 individual seeds of each cultivar during 20 hours of immersion at intervals of 1 hour using an equipment that permit an individual seed analysis (Seed Automatic Analyzer SAD 9000S. There were proposed two statistical models to study the EC along the time of the 10 cultivars studied using SAS Statistics Program, to select the model that better allow us to understand the EC behavior along the time. Model 1 allowed to make comparisons of EC along the time between cultivars and to study the influence of the production environment on the physiological quality of soybean seeds. The time to reach the stabilization of the EC must not be lower than 19 hours for the different cultivars.

  19. Factors influencing delay time and coronary arterial density during coronary angiography with DSCT.

    Science.gov (United States)

    Tang, Lijun; Zhu, Xiaomei; Xu, Yi; Yu, Tongfu; Xu, Hai; Tang, Jinhua; Dogra, Vikram; Wang, Dehang

    2011-02-01

    CT angiography (CTA) plays an important role in diagnosing coronary arterial disease. Delay time and density of the coronary arteries related with patient-specific factors are essential for getting an optimal CTA image. To investigate various factors influencing delay time and coronary arterial density during coronary CTA with dual source CT. One hundred and sixteen consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Factors including gender, age, height, weight, transversal cardiac diameter (TCD), transversal thoracic diameter (TTD), heart rate (HR), body surface area (BSA = [weight × height/3600](1/2)) and cardiothoracic ratio (CTR = TCD/TTD) were recorded, measured and calculated before administration of contrast media during coronary CT angiography. Delay time was determined as duration from the beginning of the injection to the density in the descending aorta at the level of right main pulmonary artery reaching a threshold of 100 HU. Coronary arterial density was measured at the mid portion of the right coronary artery. Regression analysis and stepwise regression analysis were used to investigate the influence of these factors on delay time and coronary arterial density. Delay time decreased with an increasing HR and it was shorter in women than men. Delay time increased with an increasing TCD. Delay time could be predicted by the formula: DT = 16.651-0.110 × HR + 1.902 × gender + 0.394 × TCD (where DT is abbreviation for delay time, gender is 0 for women and 1 for men). Coronary arterial density decreased with an increasing HR and weight. Coronary arterial density could be predicted by the formula: CAD = 923.42-4.099 × HR-3.293 × weight (CAD = coronary arterial density). There was no relationship between the other factors mentioned above and delay time or coronary arterial density. Delay time is influenced by HR, gender and TCD. Coronary arterial density also changes with HR and weight. So HR, gender, TCD and

  20. On renormalisation of lambda phi4 field theory in curved space-time

    International Nuclear Information System (INIS)

    Bunch, T.S.; Panangaden, P.

    1980-01-01

    An explicit renormalisation of all second-order physical processes occurring in lambdaphi 4 field theory in conformally flat space-time, including vacuum-to-vacuum processes, is performed. Although divergences dependent on the definition of the vacuum state appear in some Feynman diagrams, physical amplitudes obtained by summing all diagrams which contribute to a single physical process are independent of these divergences. Consequently, the theory remains renormalisable in curved space-time, at least to second order in lambda. Renormalisations of the mass m, the coupling constant lambda and the constant xi which couples the field to the Ricci scalar are required to make two- and four-particle creation amplitudes finite. (author)

  1. Influence of angiographic collateral circulation on myocardial perfusion in patients with chronic total occlusion of a single coronary artery and no prior myocardial infarction.

    Science.gov (United States)

    Aboul-Enein, Fatma; Kar, Saibal; Hayes, Sean W; Sciammarella, Maria; Abidov, Aiden; Makkar, Raj; Friedman, John D; Eigler, Neal; Berman, Daniel S

    2004-06-01

    The functional role of various angiographic grades for coronary collaterals remains controversial. The aim of this study was to assess the influence of the Rentrop angiographic grading of coronary collaterals on myocardial perfusion in patients with single-vessel chronic total occlusion (CTO) and no prior myocardial infarction (MI). The study included 56 patients with single-vessel CTO and no prior MI who underwent rest-stress myocardial perfusion SPECT and coronary angiography within 6 mo. All patients had angiographic evidence of coronary collaterals. Patients were divided according to the Rentrop classification: Group I had grade 1 or 2 (n = 25) and group II had grade 3 collaterals (n = 31). Group I had a higher frequency of resting regional wall motion abnormalities on left ventriculography (52.6% vs. 19.2% [P = 0.019]). The mean perfusion scores of the overall population showed severe and extensive stress perfusion defects (summed stress score of 14.1 +/- 7.1 and summed difference score of 12.9 +/- 6.9) but minimal resting perfusion defects (summed rest score of 1.0 +/- 2.7). No perfusion scores differed between the 2 groups. The perfusion findings suggested that chronic stunning rather than hibernation is the principal cause of regional wall motion abnormalities in these patients. In the setting of single-vessel CTO and no prior MI, coronary collaterals appear to protect against resting perfusion defects. Excellent angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defects.

  2. [Multidisciplinary protocol for computed tomography imaging and angiographic embolization of splenic injury due to trauma: assessment of pre-protocol and post-protocol outcomes].

    Science.gov (United States)

    Koo, M; Sabaté, A; Magalló, P; García, M A; Domínguez, J; de Lama, M E; López, S

    2011-11-01

    To assess conservative treatment of splenic injury due to trauma, following a protocol for computed tomography (CT) and angiographic embolization. To quantify the predictive value of CT for detecting bleeding and need for embolization. The care protocol developed by the multidisciplinary team consisted of angiography with embolization of lesions revealed by contrast extravasation under CT as well as embolization of grade III-V injuries observed, or grade I-II injuries causing hemodynamic instability and/or need for blood transfusion. We collected data on demographic variables, injury severity score (ISS), angiographic findings, and injuries revealed by CT. Pre-protocol and post-protocol outcomes were compared. The sensitivity and specificity of CT findings were calculated for all patients who required angiographic embolization. Forty-four and 30 angiographies were performed in the pre- and post-protocol periods, respectively. The mean (SD) ISSs in the two periods were 25 (11) and 26 (12), respectively. A total of 24 (54%) embolizations were performed in the pre-protocol period and 28 (98%) after implementation of the protocol. Two and 7 embolizations involved the spleen in the 2 periods, respectively; abdominal laparotomies numbered 32 and 25, respectively, and 10 (31%) vs 4 (16%) splenectomies were performed. The specificity and sensitivity values for contrast extravasation found on CT and followed by embolization were 77.7% and 79.5%. The implementation of this multidisciplinary protocol using CT imaging and angiographic embolization led to a decrease in the number of splenectomies. The protocol allows us to take a more conservative treatment approach.

  3. Angiographic validation of the American College of Cardiology Foundation-the Society of Thoracic Surgeons Collaboration on the Comparative Effectiveness of Revascularization Strategies study.

    Science.gov (United States)

    Chakrabarti, Anjan K; Grau-Sepulveda, Maria V; O'Brien, Sean; Abueg, Cassandra; Ponirakis, Angelo; Delong, Elizabeth; Peterson, Eric; Klein, Lloyd W; Garratt, Kirk N; Weintraub, William S; Gibson, C Michael

    2014-02-01

    The goal of this study was to compare angiographic interpretation of coronary arteriograms by sites in community practice versus those made by a centralized angiographic core laboratory. The study population consisted of 2013 American College of Cardiology-National Cardiovascular Data Registry (ACC-NCDR) records with 2- and 3- vessel coronary disease from 54 sites in 2004 to 2007. The primary analysis compared Registry (NCDR)-defined 2- and 3-vessel disease versus those from an angiographic core laboratory analysis. Vessel-level kappa coefficients suggested moderate agreement between NCDR and core laboratory analysis, ranging from kappa=0.39 (95% confidence intervals, 0.32-0.45) for the left anterior descending artery to kappa=0.59 (95% confidence intervals, 0.55-0.64) for the right coronary artery. Overall, 6.3% (n=127 out of 2013) of those patients identified with multivessel disease at NCDR sites had had 0- or 1-vessel disease by core laboratory reading. There was no directional bias with regard to overcall, that is, 12.3% of cases read as 3-vessel disease by the sites were read as <3-vessel disease by the core laboratory, and 13.9% of core laboratory 3-vessel cases were read as <3-vessel by the sites. For a subset of patients with left main coronary disease, registry overcall was not linked to increased rates of mortality or myocardial infarction. There was only modest agreement between angiographic readings in clinical practice and those from an independent core laboratory. Further study will be needed because the implications for patient management are uncertain.

  4. Correlation of C-Reactive Protein and Cardiac Enzymes with Angiographic Severity of Coronary Artery Disease in Pakistani Patients with Acute Coronary Syndrome.

    Science.gov (United States)

    Saleem, Ayesha; Ali, Azmat

    2017-02-01

    To determine the correlation of C-reactive protein (CRP) levels with the severity of coronary stenosis on angiography and the association of cardiac enzymes with the degree of stenosis in acute coronary syndrome (ACS) patients. Secondly, to compare association of angiographic severity of vascular stenosis with CRP in patients with ST segment elevation myocardial infarction (STEMI) and non-STEMI / Unstable angina (UA). Prospective, descriptive study. Khan Research Laboratories (KRL) Hospital, from October 2014 to March 2015. CRP was measured on diagnosis of ACS in 70 patients. Cardiac enzymes were measured 6 hours after the onset of chest pain. Angiographic scoring for degree of stenosis and number of culprit vessels was done. Two groups consisting of patients with STEMI (group 1) and with NSTEMI/UA (group 2) were made. No correlation was found between CRP levels and angiographic stenosis in patients with ACS (r=0.162, p>0.05). No association was found between eosinophil count and severity of stenosis (p=0.88). Rise of cardiac enzymes and degree of coronary stenosis showed a positive correlation (p Rise in cardiac enzymes still grade high in predicting severity of vascular stenosis than eosinophil count or CRP levels.

  5. The association of elastin gene variants with two angiographic subtypes of polypoidal choroidal vasculopathy.

    Directory of Open Access Journals (Sweden)

    Suiho Yanagisawa

    Full Text Available To compare the association of elastin (ELN gene variants between two different angiographic phenotypes of polypoidal choroidal vasculopathy (PCV.We included 411 treatment-naïve PCV patients and 350 controls in the present study. PCV was classified into two phenotypes (152 Type 1 and 259 Type 2 according to the presence or absence of feeding vessels found in indocyanine-green angiography. Single nucleotide polymorphisms (SNPs in the ELN region including rs868005, rs884843, rs2301995, rs13239907 and rs2856728 were genotyped using TaqMan Genotyping Assays.In the allelic association analyses, rs868005 showed the strongest association with Type 2 PCV (allelic odds ratio 1.56; p = 7.4x10(-6, while no SNP was significantly associated with Type 1 PCV. Genotype association analyses revealed the significant association of rs868005 with Type 2 PCV in log additive model and predominant model (odds ratio 1.75; p = 1.5x10(-6 and odds ratio 1.60; p = 0.0044, respectively, but not with Type 1 PCV. These findings were further corroborated by another control group in the literature.There may be significantly different associations in genetic variants of elastin between two angiographic phenotypes of PCV.

  6. Spiral Galaxy Central Bulge Tangential Speed of Revolution Curves

    Science.gov (United States)

    Taff, Laurence

    2013-03-01

    The objective was to, for the first time in a century, scientifically analyze the ``rotation curves'' (sic) of the central bulges of scores of spiral galaxies. I commenced with a methodological, rational, geometrical, arithmetic, and statistical examination--none of them carried through before--of the radial velocity data. The requirement for such a thorough treatment is the paucity of data typically available for the central bulge: fewer than 10 observations and frequently only five. The most must be made of these. A consequence of this logical handling is the discovery of a unique model for the central bulge volume mass density resting on the positive slope, linear, rise of its tangential speed of revolution curve and hence--for the first time--a reliable mass estimate. The deduction comes from a known physics-based, mathematically valid, derivation (not assertion). It rests on the full (not partial) equations of motion plus Poisson's equation. Following that is a prediction for the gravitational potential energy and thence the gravitational force. From this comes a forecast for the tangential speed of revolution curve. It was analyzed in a fashion identical to that of the data thereby closing the circle and demonstrating internal self-consistency. This is a hallmark of a scientific method-informed approach to an experimental problem. Multiple plots of the relevant quantities and measures of goodness of fit will be shown. Astronomy related

  7. Corrected thrombolysis in myocardial infarction frame counts in diabetic patients with angiographically normal coronary arteries

    International Nuclear Information System (INIS)

    Turkoglu, S.; Ozdemir, M.; Tacoy, G.; Tavil, Y.; Abaci, A.; Timurkaynak, T.; Cengel, A.

    2008-01-01

    Objective was to evaluate corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) in patients with angiographically normal coronary arteries and diabetes mellitus, a condition known to be associated with microvascular dysfunction. Patients who underwent coronary angiography in Gazi University Hospital, Ankara, Turkey between January 2000 and January 2005 were studied. Corrected TIMI frame count was left circumflex (Cx) and right coronary arteries (RCA) in 118 diabetic and 122 non-diabetic patients with normal coronary angiogram. The mean CTFC values of the LAD, Cx and the RCA were similar in diabetics and nondiabetics (21.0+-7.5 versus 21.3+-9.6, 23.3+-9.7 versus 23.5+-10.8, 17.9+-6.7 versus 18.7+-7.4 respectively, p>0.05 for all comparisons). In stepwise multivariate linear regression analysis, body surface area had a significant correlation with CTFC of all the 3 coronary arteries. We conclude that CTFC in diabetics and non-diabetics with angiographically normal coronary arteries is similar. Since microvascular disease is an inherent component of diabetes, our finding may reflect the inadequacy of CTFC in predicting microvascular disease in diabetic patients with normal coronary angiograms. (author)

  8. The curvature of sensitometric curves for Kodak XV-2 film irradiated with photon and electron beams.

    Science.gov (United States)

    van Battum, L J; Huizenga, H

    2006-07-01

    Sensitometric curves of Kodak XV-2 film, obtained in a time period of ten years with various types of equipment, have been analyzed both for photon and electron beams. The sensitometric slope in the dataset varies more than a factor of 2, which is attributed mainly to variations in developer conditions. In the literature, the single hit equation has been proposed as a model for the sensitometric curve, as with the parameters of the sensitivity and maximum optical density. In this work, the single hit equation has been translated into a polynomial like function as with the parameters of the sensitometric slope and curvature. The model has been applied to fit the sensitometric data. If the dataset is fitted for each single sensitometric curve separately, a large variation is observed for both fit parameters. When sensitometric curves are fitted simultaneously it appears that all curves can be fitted adequately with a sensitometric curvature that is related to the sensitometric slope. When fitting each curve separately, apparently measurement uncertainty hides this relation. This relation appears to be dependent only on the type of densitometer used. No significant differences between beam energies or beam modalities are observed. Using the intrinsic relation between slope and curvature in fitting sensitometric data, e.g., for pretreatment verification of intensity-modulated radiotherapy, will increase the accuracy of the sensitometric curve. A calibration at a single dose point, together with a predetermined densitometer-dependent parameter ODmax will be adequate to find the actual relation between optical density and dose.

  9. Computer tomographic diagnosis and differential diagnosis of juvenile angiofibromas and angiomatous polyps

    International Nuclear Information System (INIS)

    Irnberger, T.

    1985-01-01

    Juvenile angiofibromas (JAF) and angiomatous polyps (AP) are vascular histologically benign tumors presenting with an identical clinical triad. Both lesions can be differentiated by their typical geographic pattern of growth, different pattern of tumor extension and their highly characteristic angiographic and angiocomputertomographic appearance. Time-density curves were of no use in differentiating the big variety of hypervascular lesions from each other. CT images of the vascular tumor phase after bolus injection of contrast medium however showed interesting pathomorphological details, which were extremely useful in differentiating JAF from AP and other vascular tumors. It is our opinion, that invasive angiography for diagnosing JAF has been surpassed, but is further essential for mapping of tumor perfusion, feeding vessels and praeoperative embolization therapy. (orig.) [de

  10. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    Science.gov (United States)

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  11. Real-time feedback control of the plasma density profile on ASDEX Upgrade

    International Nuclear Information System (INIS)

    Mlynek, A.; Reich, M.; Giannone, L.; Treutterer, W.; Behler, K.; Blank, H.; Buhler, A.; Cole, R.; Eixenberger, H.; Fischer, R.; Lohs, A.; Lueddecke, K.; Merkel, R.; Neu, G.; Ryter, F.; Zasche, D.

    2011-01-01

    The spatial distribution of density in a fusion experiment is of significant importance as it enters in numerous analyses and contributes to the fusion performance. The reconstruction of the density profile is therefore commonly done in offline data analysis. In this paper, we present an algorithm which allows for density profile reconstruction from the data of the submillimetre interferometer and the magnetic equilibrium in real-time. We compare the obtained results to the profiles yielded by a numerically more complex offline algorithm. Furthermore, we present recent ASDEX Upgrade experiments in which we used the real-time density profile for active feedback control of the shape of the density profile.

  12. Factors influencing delay time and coronary arterial density during coronary angiography with DSCT

    International Nuclear Information System (INIS)

    Lijun Tang; Xiaomei Zhu; Yi Xu; Tongfu Yu; Hai Xu; Jinhua Tang; Dehang Wang; Dogra, Vikram

    2011-01-01

    Background: CT angiography (CTA) plays an important role in diagnosing coronary arterial disease. Delay time and density of the coronary arteries related with patient-specific factors are essential for getting an optimal CTA image. Purpose: To investigate various factors influencing delay time and coronary arterial density during coronary CTA with dual source CT. Material and Methods: One hundred and sixteen consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Factors including gender, age, height, weight, transversal cardiac diameter (TCD), transversal thoracic diameter (TTD), heart rate (HR), body surface area (BSA = [weight x height/3600]1/2) and cardiothoracic ratio (CTR = TCD/TTD) were recorded, measured and calculated before administration of contrast media during coronary CT angiography. Delay time was determined as duration from the beginning of the injection to the density in the descending aorta at the level of right main pulmonary artery reaching a threshold of 100 HU. Coronary arterial density was measured at the mid portion of the right coronary artery. Regression analysis and stepwise regression analysis were used to investigate the influence of these factors on delay time and coronary arterial density. Results: Delay time decreased with an increasing HR and it was shorter in women than men. Delay time increased with an increasing TCD. Delay time could be predicted by the formula: DT = 16.651-0.110 x HR + 1.902 x gender + 0.394 x TCD (where DT is abbreviation for delay time, gender is 0 for women and 1 for men). Coronary arterial density decreased with an increasing HR and weight. Coronary arterial density could be predicted by the formula: CAD = 923.42-4.099 x HR-3.293 x weight (CAD = coronary arterial density). There was no relationship between the other factors mentioned above and delay time or coronary arterial density. Conclusion: Delay time is influenced by HR, gender and TCD. Coronary arterial density

  13. Unsatisfactory hepatic perfusion after placement of the infusaid pump: Angiographic correlation

    International Nuclear Information System (INIS)

    Andrews, J.C.; Williams, D.M.; Cho, K.J.; Knol, J.A.; Wahl, R.L.; Ensminger, W.D.

    1988-01-01

    Complete perfusion limited to the liver is essential to the success of regional chemotherapy for hepatic malignancy. Thirty-three patients with unsatisfactory hepatic artery perfusion scintigrams after surgical placement of a pump and catheter system were evaluated with selective angiography (31 cases) or digital subtraction angiography (DSA) via the pump side port (six cases). The cause of the perfusion defect was hepatic artery thrombosis (14 cases), extrahepatic flow through collaterals (13 cases), misplaced catheter (three cases), short proper hepatic artery without adequate length for mixing (two cases), and undefined (one case). DSA findings were diagnostic in only two cases. Angiographic findings directed attempted correction in 22 of 33 cases

  14. Extended analysis of cooling curves

    International Nuclear Information System (INIS)

    Djurdjevic, M.B.; Kierkus, W.T.; Liliac, R.E.; Sokolowski, J.H.

    2002-01-01

    Thermal Analysis (TA) is the measurement of changes in a physical property of a material that is heated through a phase transformation temperature range. The temperature changes in the material are recorded as a function of the heating or cooling time in such a manner that allows for the detection of phase transformations. In order to increase accuracy, characteristic points on the cooling curve have been identified using the first derivative curve plotted versus time. In this paper, an alternative approach to the analysis of the cooling curve has been proposed. The first derivative curve has been plotted versus temperature and all characteristic points have been identified with the same accuracy achieved using the traditional method. The new cooling curve analysis also enables the Dendrite Coherency Point (DCP) to be detected using only one thermocouple. (author)

  15. Influence of the curve density relative electron in dosimetry clinic in treatments stereo tactics; Influencia de la curva de densidad electronica relativa en la dosimetria clinica en tratamientos estereotaxicos

    Energy Technology Data Exchange (ETDEWEB)

    Moreno Saiz, C.; Benitez Villegas, E. M.; Casado Villalon, F. J.; Parra Osorio, V.; Bodineau Gil, C.; Garcia Pareja, S.

    2013-07-01

    The objective of this study is to analyze the difference between clinical dosimetry in the treatments with radiosurgery and stereotactic radiotherapy fractional obtained from the relative Electron density curve (Schneider 1996) tabulated and provided with the scanner's radiation therapy. (Author)

  16. Clinical Investigation of Radiation Retinopathy Fundus and Fluorescein Angiographic Features

    Institute of Scientific and Technical Information of China (English)

    LiMei; QiuGT

    1999-01-01

    Purpose:To investigate the fundus and fluorescein angiographic features in the patients with radiation retinopathy.Clinical Materials:Color fundus photography and/or fluorescein angiography from 13 patients with nasopharyngeal carcinomas received external beam radiation were retrospectively analyzed.Reslts:In this study,26 damaged eyes of 13 patients eveloped some degree of radiation retinopathy.The earliest and most common finding was macular microvascular changes (microaneurysms and/or telangiectasia),which was observed in 100%(26/26)of the eyes.Intraretinal hemorrhages,macular capillary nonperfusion,and macular edema were noted in 84%,50%,and 42% of the eyes,respectively.Conclusions:Radiation retinopathy is common after external beam radiation of nasopharyngeal carcinomas.The prominent changes include maular microvascular changes,intraretinal hemorrhages and macular capillary nonperfusion.

  17. The angiographic findings of coronary arterial spasm (a report of 37 cases)

    International Nuclear Information System (INIS)

    Kuang Jianyi; Chen Jianhun; Du Zhimin; Li Xiangmin; Hu Chengheng

    2002-01-01

    Objective: The arterial spasm which often seen in the coronary angiography was considered as a result of the pathological spasm of the coronary artery or a complication of catheterization. The coronary arterial spasm is a considerable situation because it increases the danger of stenotic lesions in coronary artery, which should be managed immediately. Methods: In total 37 patients presented with coronary arterial spasm in the coronary angiography (Judkins method): 23 male and 14 female, aged 43-60 years (the 47 years in average). Spasms were relieved in all patients after the administration of glonoin. Results: Solitary spasm were the most common, the angiographic findings were long section (>10 mm) with stenosis of 50%-65% in left anterior descending artery (12 cases), or in the middle and near portion of the right coronary artery (5 cases), where the orifice of the branches were involved; severe stenosis of the orifice of the right coronary artery (3 cases); irregular, mild and local spasm in left anterior descending artery or circumflex (8 cases). And multiple spasm was observed in left anterior descending artery (4 cases) or in the right coronary artery (5 cases). In 19 cases, stenosis accompanying with spasm were revealed and local spasm were observed at the site of arterial sclerosis. Conclusion: The spasm owing to the catheterization doesn't result in chest discomfort and changes in EKG, while pathological spasm occurs in the population with high risk of coronary heart disease, which indicates the potential myocardial infraction. The angiographic findings helps differentiating the two situation

  18. Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Active Curves

    International Nuclear Information System (INIS)

    Kim, Ok Hwa; Bahk, Yong Whee; Kim, Chi Kyung

    1987-01-01

    The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atriurn, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intracardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/ QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs

  19. A fast density-based clustering algorithm for real-time Internet of Things stream.

    Science.gov (United States)

    Amini, Amineh; Saboohi, Hadi; Wah, Teh Ying; Herawan, Tutut

    2014-01-01

    Data streams are continuously generated over time from Internet of Things (IoT) devices. The faster all of this data is analyzed, its hidden trends and patterns discovered, and new strategies created, the faster action can be taken, creating greater value for organizations. Density-based method is a prominent class in clustering data streams. It has the ability to detect arbitrary shape clusters, to handle outlier, and it does not need the number of clusters in advance. Therefore, density-based clustering algorithm is a proper choice for clustering IoT streams. Recently, several density-based algorithms have been proposed for clustering data streams. However, density-based clustering in limited time is still a challenging issue. In this paper, we propose a density-based clustering algorithm for IoT streams. The method has fast processing time to be applicable in real-time application of IoT devices. Experimental results show that the proposed approach obtains high quality results with low computation time on real and synthetic datasets.

  20. C-reactive protein and angiographic characteristics of stable and unstable coronary artery disease : Data from the prospective PREVEND cohort

    NARCIS (Netherlands)

    Geluk, C.A.; Post, W.J.; Hillege, H.L.; Tio, R.A.; Tijssen, J.G.; van Dijk, R.B.; Dijk, Willem; Bakker, S.J.; de Jong, P.E.; van Gilst, W.H.; Zijlstra, F.

    Aims: High sensitive-C-reactive protein (hs-CRP) is associated with coronary risk, which may be explained by an association with (unstable) coronary artery disease (CAD). Until now, histopathological and angiographic studies have failed to consistently demonstrate a strong relationship. However,

  1. GDC 360 for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D coils in 38 patients

    International Nuclear Information System (INIS)

    Taschner, Christian A.; Thines, Laurent; Lejeune, Jean-Paul; El-Mahdy, Mohamed; Rachdi, Henda; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2009-01-01

    The purpose of this study was to determine whether coil embolisation with a new complex-shaped Guglielmi Detachable Coil (GDC 360 ; Boston Scientific Neurovascular, Fremont, CA, USA) has any effect on the stability of aneurysm occlusion. Fifty-one consecutive patients with intracranial aneurysms treated with GDC 360 were included. Angiographic results and adverse neurological events during the follow-up period were recorded. For 38 patients treated with GDC 360 with available follow-up data, a corresponding patient treated with GDC 3D was identified from our database. Matches were sought for rupture status, location, aneurysmal size, and neck size. The angiographic outcome of these matched controls at 6 months was compared to aneurysms treated with GDC 360 . Initial angiographic controls for 38 patients treated with GDC 360 showed complete occlusion in 32 aneurysms, and a neck remnant in six. At 6-month follow-up, complete occlusion was found in 29, a neck remnant in eight, and a residual aneurysm in one. One patient treated with GDC 360 needed retreatment for a major recanalisation. In 38 matched patients treated with GDC 3D, initial angiographic controls found complete aneurysmal occlusion in 30 aneurysms and a residual neck in 8. At 6-month follow-up, 24 aneurysms were completely occluded, ten showed a neck remnant, and residual aneurysms were seen in four. Four patients, treated with GDC 3D, were retreated for major aneurysm recanalisations. Our data suggests that endovascular coil embolisation with GDC 360 might improve long-term stability of coiled aneurysms when compared to GDC 3D. (orig.)

  2. Angiographic Validation of the American College of Cardiology Foundation–The Society of Thoracic Surgeons Collaboration on the Comparative Effectiveness of Revascularization Strategies Study

    Science.gov (United States)

    Chakrabarti, Anjan K.; Grau-Sepulveda, Maria V.; O’Brien, Sean; Abueg, Cassandra; Ponirakis, Angelo; Delong, Elizabeth; Peterson, Eric; Klein, Lloyd W.; Garratt, Kirk N.; Weintraub, William S.; Gibson, C. Michael

    2017-01-01

    Background The goal of this study was to compare angiographic interpretation of coronary arteriograms by sites in community practice versus those made by a centralized angiographic core laboratory. Methods and Results The study population consisted of 2013 American College of Cardiology–National Cardiovascular Data Registry (ACC–NCDR) records with 2- and 3- vessel coronary disease from 54 sites in 2004 to 2007. The primary analysis compared Registry (NCDR)-defined 2- and 3-vessel disease versus those from an angiographic core laboratory analysis. Vessel-level kappa coefficients suggested moderate agreement between NCDR and core laboratory analysis, ranging from kappa=0.39 (95% confidence intervals, 0.32–0.45) for the left anterior descending artery to kappa=0.59 (95% confidence intervals, 0.55–0.64) for the right coronary artery. Overall, 6.3% (n=127 out of 2013) of those patients identified with multivessel disease at NCDR sites had had 0- or 1-vessel disease by core laboratory reading. There was no directional bias with regard to overcall, that is, 12.3% of cases read as 3-vessel disease by the sites were read as <3-vessel disease by the core laboratory, and 13.9% of core laboratory 3-vessel cases were read as <3-vessel by the sites. For a subset of patients with left main coronary disease, registry overcall was not linked to increased rates of mortality or myocardial infarction. Conclusions There was only modest agreement between angiographic readings in clinical practice and those from an independent core laboratory. Further study will be needed because the implications for patient management are uncertain. PMID:24496239

  3. Candidate Binary Trojan and Hilda Asteroids from Rotational Light Curves

    Science.gov (United States)

    Sonnett, Sarah M.; Mainzer, Amy K.; Grav, Tommy; Masiero, Joseph R.; Bauer, James M.; Kramer, Emily A.

    2017-10-01

    Jovian Trojans (hereafter, Trojans) are asteroids in stable orbits at Jupiter's L4 and L5 Lagrange points, and Hilda asteroids are inwards of the Trojans in 3:2 mean-motion resonance with Jupiter. Due to their special dynamical properties, observationally constraining the formation location and dynamical histories of Trojans and HIldas offers key input for giant planet migration models. A fundamental parameter in assessing formation location is the bulk density - with low-density objects associated with an ice-rich formation environment in the outer solar system and high-density objects typically linked to the warmer inner solar system. Bulk density can only be directly measured during a close fly-by or by determining the mutual orbits of binary asteroid systems. With the aim of determining densities for a statistically significant sample of Trojans and Hildas, we are undertaking an observational campaign to confirm and characterize candidate binary asteroids published in Sonnett et al. (2015). These objects were flagged as binary candidates because their large NEOWISE brightness variations imply shapes so elongated that they are not likely explained by a singular equilibrium rubble pile and instead may be two elongated, gravitationally bound asteroids. We are obtaining densely sampled rotational light curves of these possible binaries to search for light curve features diagnostic of binarity and to determine the orbital properties of any confirmed binary systems by modeling the light curve. We compare the We present an update on this follow-up campaign and comment on future steps.

  4. Vacuum quantum effect for curved boundaries in static Robertson-Walker space-time

    International Nuclear Information System (INIS)

    Setare, M.R.; Sadeghi, J.

    2009-01-01

    The energy-momentum tensor for a massless conformally coupled scalar field in the region between two curved boundaries in k=-1 static Robertson-Walker space-time is investigated. We assume that the scalar field satisfies the Dirichlet boundary condition on the boundaries. k=-1 Robertson-Walker space is conformally related to the Rindler space, as a result we can obtain vacuum expectation values of energy-momentum tensor for conformally invariant field in Robertson-Walker space from the corresponding Rindler counterpart by the conformal transformation.

  5. Clinical and angiographic evaluation of the topic application of nitrate compounds in obstructive distal arteriopathies of the legs

    International Nuclear Information System (INIS)

    Perini, L.; Cavallo, A.; Perin, B.; Natale, F.; Borelli, G.; Bisiato, R.

    1988-01-01

    The vasodilatator effect obtained by the topic use of a nytroglycerin compound (TNG) has been angiographically tested on 11 patients affected by distal arteriopathy of the legs. All patients presented arteriosclerotic vascular lesions; two of them also suffered from diabetic angiopathy. Arteriography of the legs has proved to be a very important tool in the evaluation of the patients'response to the administration of the drug. An hour after 80 mg of TNG had been applied to the skin of the examined leg, arteriography showed a marked dilatation, especially of the muscular arteries and the undamaged tracts of the arteries of the legs. Angiographic evaluation of the functional blood supply thus obtained provides prognostic information and helps in the choice of the subsequent therapy. Furthermore, the clinical efficacy of prolonged treatment with this drug has been tested in 10 out of the 11 patients. They all responded with an immediate and persistent hemodynamic improvement, evaluated according to Fontaine's classification

  6. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease

    DEFF Research Database (Denmark)

    Onuma, Yoshinobu; Dudek, Dariusz; Thuesen, Leif

    2013-01-01

    This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California).......This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California)....

  7. Type IIP supernova light curves affected by the acceleration of red supergiant winds

    Science.gov (United States)

    Moriya, Takashi J.; Förster, Francisco; Yoon, Sung-Chul; Gräfener, Götz; Blinnikov, Sergei I.

    2018-05-01

    We introduce the first synthetic light-curve model set of Type IIP supernovae exploded within circumstellar media in which the acceleration of the red supergiant winds is taken into account. Because wind acceleration makes the wind velocities near the progenitors low, the density of the immediate vicinity of the red supergiant supernova progenitors can be higher than that extrapolated by using a constant terminal wind velocity. Therefore, even if the mass-loss rate of the progenitor is relatively low, it can have a dense circumstellar medium at the immediate stellar vicinity and the early light curves of Type IIP supernovae are significantly affected by it. We adopt a simple β velocity law to formulate the wind acceleration. We provide bolometric and multicolour light curves of Type IIP supernovae exploding within such accelerated winds from the combinations of three progenitors, 12-16 M⊙; five β, 1-5; seven mass-loss rates, 10-5-10-2 M⊙ yr-1; and four explosion energies, (0.5-2) × 1051 erg. All the light-curve models are available at https://goo.gl/o5phYb. When the circumstellar density is sufficiently high, our models do not show a classical shock breakout as a consequence of the interaction with the dense and optically thick circumstellar media. Instead, they show a delayed `wind breakout', substantially affecting early light curves of Type IIP supernovae. We find that the mass-loss rates of the progenitors need to be 10-3-10-2 M⊙ yr-1 to explain typical rise times of 5-10 d in Type IIP supernovae assuming a dense circumstellar radius of 1015 cm.

  8. Effects of statistical quality, sampling rate and temporal filtering techniques on the extraction of functional parameters from the left ventricular time-activity curves

    Energy Technology Data Exchange (ETDEWEB)

    Guignard, P.A.; Chan, W. (Royal Melbourne Hospital, Parkville (Australia). Dept. of Nuclear Medicine)

    1984-09-01

    Several techniques for the processing of a series of curves derived from two left ventricular time-activity curves acquired at rest and during exercise with a nuclear stethoscope were evaluated. They were three and five point time smoothing. Fourier filtering preserving one to four harmonics (H), truncated curve Fourier filtering, and third degree polynomial curve fitting. Each filter's ability to recover, with fidelity, systolic and diastolic function parameters was evaluated under increasingly 'noisy' conditions and at several sampling rates. Third degree polynomial curve fittings and truncated Fourier filters exhibited very high sensitivity to noise. Three and five point time smoothing had moderate sensitivity to noise, but were highly affected by sampling rate. Fourier filtering preserving 2H or 3H produced the best compromise with high resilience to noise and independence of sampling rate as far as the recovery of these functional parameters is concerned.

  9. Effects of statistical quality, sampling rate and temporal filtering techniques on the extraction of functional parameters from the left ventricular time-activity curves

    International Nuclear Information System (INIS)

    Guignard, P.A.; Chan, W.

    1984-01-01

    Several techniques for the processing of a series of curves derived from two left ventricular time-activity curves acquired at rest and during exercise with a nuclear stethoscope were evaluated. They were three and five point time smoothing. Fourier filtering preserving one to four harmonics (H), truncated curve Fourier filtering, and third degree polynomial curve fitting. Each filter's ability to recover, with fidelity, systolic and diastolic function parameters was evaluated under increasingly 'noisy' conditions and at several sampling rates. Third degree polynomial curve fittings and truncated Fourier filters exhibited very high sensitivity to noise. Three and five point time smoothing had moderate sensitivity to noise, but were highly affected by sampling rate. Fourier filtering preserving 2H or 3H produced the best compromise with high resilience to noise and independence of sampling rate as far as the recovery of these functional parameters is concerned. (author)

  10. ADN* Density log estimation Using Rockcell*

    International Nuclear Information System (INIS)

    Okuku, C.; Iloghalu, Emeka. M.; Omotayo, O.

    2003-01-01

    This work is intended to inform on the possibilities of estimating good density data in zones associated with sliding in a reservoir with ADN* tool with or without ADOS in string in cases where repeat sections were not done, possibly due to hole stability or directional concerns. This procedure has been equally used to obtain a better density data in corkscrew holes. Density data (ROBB) was recomputed using neural network in RockCell* to estimate the density over zones of interest. RockCell* is a Schlumberger software that has neural network functionally which can be used to estimate missing logs using the combination of the responses of other log curves and intervals that are not affected by sliding. In this work, an interval was selected and within this interval twelve litho zones were defined using the unsupervised neural network. From this a training set was selected based on intervals of very good log responses outside the sliding zones. This training set was used to train and run the neural network for a specific lithostratigraphic interval. The results matched the known good density curve. Then after this, an estimation of the density curve was done using the supervised neural network. The output from this estimation matched very closely in the good portions of the log, thus providing some density measurements in the sliding zone. This methodology provides a scientific solution to missing data during the process of Formation evaluation

  11. The subtype of VSD and the angiographic differentiation

    International Nuclear Information System (INIS)

    Choe, Kyu Ok; Sul, Jun Hee; Lee, Sung Kyu; Cho, Bum Koo; Hong, Sung Nok

    1985-01-01

    VSD is the most common congenital cardiac malformation and the natural history depends not only on the age of patients and the size of defect but the subtype of VSD as well, important factor in clinical management of those patients. In 110 patients, with surgically repaired VSD in Yonsei Medical Center in 1984, the subtype of VSDs evaluated by surgical observation were correlated with LV angiogram findings to verify the incidence of subtype in Korean and the diagnostic accuracy to predict the subtype by angiogram. 1. 110 patients included 64 boys and 46 girls, the age ranged from 3 months to 14 years (average 4.6 years old). 2. Angiographic findings were interpreted as follows; a. Perimembranous defects were profiled in LAO 60 .deg. LV angiogram and located below the aortic valve. In inlet excavation the shunted blood opacified the recess between septal leaflet of tricuspid valve and interventricular septum in early phase, in infundibular excavation opacified the recess between anterior leaflet of TV and anterior free wall of RV and in trabecular excavation the shunted blood traversed anterior portion of TV ring, opacified trabecular portion of RV cavity. b. Subarterial types were profiled in RAO 30 .deg. LV angiogram, just below aortic valve as well as pulmonic valve. Total infundibular defects were profiled in RAO 30 .deg. and LAO 60 .deg. LV angiogram subaortic in location in both views. c. In muscular VSD the profiled angle was varied according to the subtype but the defects were separated from the aortic valve as muscular septum interposed between the aortic valve and the defect. 3. The incidence of subtype of VSDs evaluated by surgical observation were as follows. Subarterial type : 32 cases (29.1%) Total infundibular defect : 5 cases (4.5%) Perimembranous type : 73 cases (66.3%) Infundibular excavation : 32 cases (29.2%) Trabecular excavation : 28 cases (25.5%) Inlet excavation : 10 cases (9.1%) Mixed : 3 cases (2.7%) Muscular type : 1 cases (0.9%) Total 63

  12. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  13. Characteristics of time-activity curves obtained from dynamic 11C-methionine PET in common primary brain tumors.

    Science.gov (United States)

    Nomura, Yuichi; Asano, Yoshitaka; Shinoda, Jun; Yano, Hirohito; Ikegame, Yuka; Kawasaki, Tomohiro; Nakayama, Noriyuki; Maruyama, Takashi; Muragaki, Yoshihiro; Iwama, Toru

    2018-07-01

    The aim of this study was to assess whether dynamic PET with 11 C-methionine (MET) (MET-PET) is useful in the diagnosis of brain tumors. One hundred sixty patients with brain tumors (139 gliomas, 9 meningiomas, 4 hemangioblastomas and 8 primary central nervous system lymphomas [PCNSL]) underwent dynamic MET-PET with a 3-dimensional acquisition mode, and the maximum tumor MET-standardized uptake value (MET-SUV) was measured consecutively to construct a time-activity curve (TAC). Furthermore, receiver operating characteristic (ROC) curves were generated from the time-to-peak (TTP) and the slope of the curve in the late phase (SLOPE). The TAC patterns of MET-SUVs (MET-TACs) could be divided into four characteristic types when MET dynamics were analyzed by dividing the MET-TAC into three phases. MET-SUVs were significantly higher in early and late phases in glioblastoma compared to anaplastic astrocytoma, diffuse astrocytoma and the normal frontal cortex (P dynamic MET-PET study could be helpful in the non-invasive discrimination of brain tumor subtypes, in particular gliomas.

  14. Tempo curves considered harmful

    NARCIS (Netherlands)

    Desain, P.; Honing, H.

    1993-01-01

    In the literature of musicology, computer music research and the psychology of music, timing or tempo measurements are mostly presented in the form of continuous curves. The notion of these tempo curves is dangerous, despite its widespread use, because it lulls its users into the false impression

  15. Quantitative density measurements from a real-time neutron radiography system

    International Nuclear Information System (INIS)

    McRae, D.D.; Jenkins, R.W. Jr.; Brenizer, J.S.; Tobin, K.W.; Hosticka, B.; Sulcoski, M.F.

    1986-01-01

    An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation

  16. Angiographically occult vascular malformation of the brain: MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Patel, S.C.; Sanders, W.P.; Fuentes, J.; Haggar, A.M.; Mehta, B.A.; Boulos, R.S.; Froelich, J.W.

    1986-01-01

    MR imaging was performed in nine patients with 12 angiographically occult arteriovenous malformations using a 1.5-T superconducting magnet; four additional patients were imaged using a 0.3-T system. All images were reviewed in conjunction with CT scans. The following observations were made. (1) Eleven of 14 supratentorial lesions were located at the junction of gray and white matter. (2) Exclusing acute hemorrhage, only two lesions displayed mild mass effect. (3) All lesions displayed central foci of high signal intensity, probably representing subacute hemorrhage. (4) All lesions but one showed a peripheral rim of low signal intensity which progressively lost signal with increasing T2 weighting. This most likely represents iron-containing hemosiderin deposition. (5) Lesions were best demonstrated with long repetition times and moderate T2 weighting (TR = 2,500 msec, TE = 25-100 msec). (6) All lesions but one were hyperdense on non-contrast-enhanced CT, although only three had unequivocal calcification. The possibility of hyperdensity due to blood or iron deposition is discussed

  17. Planar-channeling spatial density under statistical equilibrium

    International Nuclear Information System (INIS)

    Ellison, J.A.; Picraux, S.T.

    1978-01-01

    The phase-space density for planar channeled particles has been derived for the continuum model under statistical equilibrium. This is used to obtain the particle spatial probability density as a function of incident angle. The spatial density is shown to depend on only two parameters, a normalized incident angle and a normalized planar spacing. This normalization is used to obtain, by numerical calculation, a set of universal curves for the spatial density and also for the channeled-particle wavelength as a function of amplitude. Using these universal curves, the statistical-equilibrium spatial density and the channeled-particle wavelength can be easily obtained for any case for which the continuum model can be applied. Also, a new one-parameter analytic approximation to the spatial density is developed. This parabolic approximation is shown to give excellent agreement with the exact calculations

  18. Fundamentals of time-dependent density functional theory

    International Nuclear Information System (INIS)

    Marques, Miguel A.L.; Rubio, Angel

    2012-01-01

    There have been many significant advances in time-dependent density functional theory over recent years, both in enlightening the fundamental theoretical basis of the theory, as well as in computational algorithms and applications. This book, as successor to the highly successful volume Time-Dependent Density Functional Theory (Lect. Notes Phys. 706, 2006) brings together for the first time all recent developments in a systematic and coherent way. First, a thorough pedagogical presentation of the fundamental theory is given, clarifying aspects of the original proofs and theorems, as well as presenting fresh developments that extend the theory into new realms such as alternative proofs of the original Runge-Gross theorem, open quantum systems, and dispersion forces to name but a few. Next, all of the basic concepts are introduced sequentially and building in complexity, eventually reaching the level of open problems of interest. Contemporary applications of the theory are discussed, from real-time coupled-electron-ion dynamics, to excited-state dynamics and molecular transport. Last but not least, the authors introduce and review recent advances in computational implementation, including massively parallel architectures and graphical processing units. Special care has been taken in editing this volume as a multi-author textbook, following a coherent line of thought, and making all the relevant connections between chapters and concepts consistent throughout. As such it will prove to be the text of reference in this field, both for beginners as well as expert researchers and lecturers teaching advanced quantum mechanical methods to model complex physical systems, from molecules to nanostructures, from biocomplexes to surfaces, solids and liquids. (orig.)

  19. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis

    International Nuclear Information System (INIS)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-01-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P=0.25) nor DSA (P=1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P=1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis.

  20. Chest pain in patients with arterial hypertension, angiographically normal coronary arteries and stiff aorta: the aortic pain syndrome.

    Science.gov (United States)

    Stakos, Dimitrios A; Tziakas, Dimitrios N; Chalikias, George; Mitrousi, Konstantina; Tsigalou, Christina; Boudoulas, Harisios

    2013-01-01

    Arterial hypertension is often associated with a stiff aorta as a result of collagen accumulation in the aortic wall and may produce chest pain. In the present study, possible interrelationships between aortic function, collagen turnover and exercise-induced chest pain in patients with arterial hypertension and angiographically normal coronary arteries were investigated. Ninety-seven patients with arterial hypertension, angiographically normal coronary arteries and no evidence of myocardial ischemia on nuclear cardiac imaging during exercise test were studied. Of these, 43 developed chest pain during exercise (chest pain group) while 54 did not (no chest pain group). Carotid femoral pulse-wave velocity (PWVc-f) was used to assess the elastic properties of the aorta. Amino-terminal pro-peptides of pro-collagen type I, (PINP, reflecting collagen synthesis), serum telopeptides of collagen type I (CITP, reflecting collagen degradation), pro-metalloproteinase 1 (ProMMP-1), and tissue inhibitor of metalloproteinase 1 (TIMP-1, related to collagen turnover) were measured in plasma by immunoassay. The chest pain group had higher PWVc-f, higher and /CITP ratio, and lower proMMP-1/ TIMP-1 ratio compared to the no chest pain group. PWVc-f (t=2.53, p=0.02) and PINP (t=2.42, p=0.02) were independently associated with the presence of chest pain in multiple regression analysis. Patients with arterial hypertension, exercise-induced chest pain and angiographically normal coronary arteries, without evidence of exercise-induced myocardial ischemia, had a stiffer aorta compared to those without chest pain. Alterations in collagen type I turnover that favor collagen accumulation in the aortic wall may contribute to aortic stiffening and chest pain in these patients.

  1. A Fast Density-Based Clustering Algorithm for Real-Time Internet of Things Stream

    Science.gov (United States)

    Ying Wah, Teh

    2014-01-01

    Data streams are continuously generated over time from Internet of Things (IoT) devices. The faster all of this data is analyzed, its hidden trends and patterns discovered, and new strategies created, the faster action can be taken, creating greater value for organizations. Density-based method is a prominent class in clustering data streams. It has the ability to detect arbitrary shape clusters, to handle outlier, and it does not need the number of clusters in advance. Therefore, density-based clustering algorithm is a proper choice for clustering IoT streams. Recently, several density-based algorithms have been proposed for clustering data streams. However, density-based clustering in limited time is still a challenging issue. In this paper, we propose a density-based clustering algorithm for IoT streams. The method has fast processing time to be applicable in real-time application of IoT devices. Experimental results show that the proposed approach obtains high quality results with low computation time on real and synthetic datasets. PMID:25110753

  2. V-I curves and plasma parameters in a high density DC glow discharge generated by a current-source

    International Nuclear Information System (INIS)

    Granda-Gutierrez, E E; Lopez-Callejas, R; Piedad-Beneitez, A de la; BenItez-Read, J S; Pacheco-Sotelo, J O; Pena-Eguiluz, R; A, R Valencia; Mercado-Cabrera, A; Barocio, S R

    2008-01-01

    Nitrogen DC glow discharges, conducted in a cylindrical geometry, have been characterized using a new current-source able to provide 10 -3 - 3 A for the sustainment of the discharge, instead of a conventional voltage-source. The V-I characteristic curves obtained from these discharges were found to fit the general form i(v) = A(p)v k(p) , whereby the plasma itself can be modeled as a voltage-controlled current-source. We conclude that the fitting parameters A and k, which mainly depend on the gas pressure p, are strongly related to the plasma characteristics, so much so that they can indicate the pressure interval in which the maximum plasma density is located, with values in the order of 10 16 m -3 at reduced discharge potential (300-600 V) and low working pressure (10 -1 - 10 1 Pa)

  3. Continuous time random walk model with asymptotical probability density of waiting times via inverse Mittag-Leffler function

    Science.gov (United States)

    Liang, Yingjie; Chen, Wen

    2018-04-01

    The mean squared displacement (MSD) of the traditional ultraslow diffusion is a logarithmic function of time. Recently, the continuous time random walk model is employed to characterize this ultraslow diffusion dynamics by connecting the heavy-tailed logarithmic function and its variation as the asymptotical waiting time density. In this study we investigate the limiting waiting time density of a general ultraslow diffusion model via the inverse Mittag-Leffler function, whose special case includes the traditional logarithmic ultraslow diffusion model. The MSD of the general ultraslow diffusion model is analytically derived as an inverse Mittag-Leffler function, and is observed to increase even more slowly than that of the logarithmic function model. The occurrence of very long waiting time in the case of the inverse Mittag-Leffler function has the largest probability compared with the power law model and the logarithmic function model. The Monte Carlo simulations of one dimensional sample path of a single particle are also performed. The results show that the inverse Mittag-Leffler waiting time density is effective in depicting the general ultraslow random motion.

  4. Angiographic embolization in the treatment of intrahepatic arterial bleeding in patients with blunt abdominal trauma.

    Science.gov (United States)

    Kong, Ya-Lin; Zhang, Hong-Yi; He, Xiao-Jun; Zhao, Gang; Liu, Cheng-Li; Xiao, Mei; Zhen, Yu-Ying

    2014-04-01

    Angiographic embolization (AE) as an adjunct non-operative treatment of intrahepatic arterial bleeding has been widely used. The present study aimed to evaluate the efficacy of selective AE in patients with hepatic trauma. Seventy patients with intrahepatic arterial bleeding after blunt abdominal trauma who had undergone selective AE in 10 years at this institution were retrospectively reviewed. The criteria for selective AE included active extravasation on contrast-enhanced CT, an episode of hypotension or a decrease in hemoglobin level during the non-operative treatment. The data of the patients included demographics, grade of liver injuries, mechanism of blunt abdominal trauma, associated intra-abdominal injuries, indications for AE, angiographic findings, type of AE, and AE-related hepatobiliary complications. In the 70 patients, 32 (45.71%) had high-grade liver injuries. Extravazation during the early arterial phase mainly involved the right hepatic segments. Thirteen (18.57%) patients underwent embolization of intrahepatic branches and the extrahepatic trunk and these patients all developed AE-related hepatobiliary complications. In 19 patients with AE-related complications, 14 received minimally invasive treatment and recovered without severe sequelae. AE is an adjunct treatment for liver injuries. Selective and/or super-selective AE should be advocated to decrease the incidence and severity of AE-related hepatobiliary complications.

  5. Imprints of the quasar structure in time-delay light curves: Microlensing-aided reverberation mapping

    Science.gov (United States)

    Sluse, D.; Tewes, M.

    2014-11-01

    The advent of large area photometric surveys has raised a great deal of interest in the possibility of using broadband photometric data, instead of spectra, to measure the size of the broad line region of active galactic nuclei. We describe here a new method that uses time-delay lensed quasars where one or several images are affected by microlensing due to stars in the lensing galaxy. Because microlensing decreases (or increases) the flux of the continuum compared to the broad line region, it changes the contrast between these two emission components. We show that this effect can be used to effectively disentangle the intrinsic variability of those two regions, offering the opportunity to perform reverberation mapping based on single-band photometric data. Based on simulated light curves generated using a damped random walk model of quasar variability, we show that measurement of the size of the broad line region can be achieved using this method, provided one spectrum has been obtained independently during the monitoring. This method is complementary to photometric reverberation mapping and could also be extended to multi-band data. Because the effect described above produces a variability pattern in difference light curves between pairs of lensed images that is correlated with the time-lagged continuum variability, it can potentially produce systematic errors in measurement of time delays between pairs of lensed images. Simple simulations indicate that time-delay measurement techniques that use a sufficiently flexible model for the extrinsic variability are not affected by this effect and produce accurate time delays.

  6. An angiographic study of left- and right-ventricular function in patients with alcoholic heart and dilatation cardiomyopathy

    International Nuclear Information System (INIS)

    Savchenko, A.P.; Samko, A.N.; Smetnev, A.S.; Grudtsyn, G.V.

    1986-01-01

    An angiographic study of left- and right-ventricular function in 57 patients with alcoholic heart and dilatation cardiomyopathy demonstrated preclinical disorders of left-ventricular myocardial contractility and more marked right-ventricular changes in patients with second-stage chronic alcoholism. In cases of dilatation cardiomyopathy, left-ventricular dysfunction was predominant, while right-venricular changes were less pronouced

  7. Angiographic evaluation of response to preoperative chemotherapy in osteosarcoma

    International Nuclear Information System (INIS)

    Carrasco, C.H.; Charnsangavej, C.; Richii, W.; Wallace, S.; Chawla, S.P.; Raymond, A.K.; Murray, J.A.; Benjamin, R.S.

    1986-01-01

    Preoperative chemotherapy for osteosarcoma facilitates local resection for limb salvage and serves as an in vivo chemosensitivity assay. Arteriograms obtained with each intraarterial course of cisplatin in 79 patients with osteosarcoma were evaluated. Complete remission was defined as complete or nearly complete disappearance of tumor vascularity after treatment. A minimal decrease, no change, or an increase in tumor vascularity was not considered a response. If a complete remission is assumed to represent ≥ 90% histologic tumor necrosis which correlates with prolonged disease-free survival, the sensitivity of an angiographic complete remission was 95%, the specificity was 58%, the predictive value of a negative study was 90%, and the predictive value of a positive study was 75%. Angiography is the best clinical technique for evaluating the therapeutic response in osteosarcoma. Results correlate well with the degree of tumor necrosis, particularly in respect to significant residual viable tumor

  8. Aqueous Angiography: Real-Time and Physiologic Aqueous Humor Outflow Imaging.

    Directory of Open Access Journals (Sweden)

    Sindhu Saraswathy

    Full Text Available Trabecular meshwork (TM bypass surgeries attempt to enhance aqueous humor outflow (AHO to lower intraocular pressure (IOP. While TM bypass results are promising, inconsistent success is seen. One hypothesis for this variability rests upon segmental (non-360 degrees uniform AHO. We describe aqueous angiography as a real-time and physiologic AHO imaging technique in model eyes as a way to simulate live AHO imaging.Pig (n = 46 and human (n = 6 enucleated eyes were obtained, orientated based upon inferior oblique insertion, and pre-perfused with balanced salt solution via a Lewicky AC maintainer through a 1mm side-port. Fluorescein (2.5% was introduced intracamerally at 10 or 30 mm Hg. With an angiographer, infrared and fluorescent (486 nm images were acquired. Image processing allowed for collection of pixel information based on intensity or location for statistical analyses. Concurrent OCT was performed, and fixable fluorescent dextrans were introduced into the eye for histological analysis of angiographically active areas.Aqueous angiography yielded high quality images with segmental patterns (p<0.0001; Kruskal-Wallis test. No single quadrant was consistently identified as the primary quadrant of angiographic signal (p = 0.06-0.86; Kruskal-Wallis test. Regions of high proximal signal did not necessarily correlate with regions of high distal signal. Angiographically positive but not negative areas demonstrated intrascleral lumens on OCT images. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways.Aqueous angiography is a real-time and physiologic AHO imaging technique in model eyes.

  9. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    International Nuclear Information System (INIS)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-01-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava. (orig.) [de

  10. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    Energy Technology Data Exchange (ETDEWEB)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-06-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava.

  11. A short-run new analytical ultracentrifugal micromethod for determining low-density lipoprotein sub-fractions using Schlieren refractometry.

    Science.gov (United States)

    Bozóky, Z; Fülöp, L; Köhidai, L

    2001-01-01

    We have developed a new analytical ultracentrifugal micromethod for the determination of serum low-density lipoprotein (LDL) subclasses directly from ultracentrifugal Schlieren scans. We have used special software for the analysis of this type of single-spin density-gradient ultracentrifugation. The flotation of LDL patterns was obtained by underlayering a physiological salt solution with serum or isolated lipoprotein fractions raised to a density of 1.3 g/mL in the spinning ultracentrifugation capillary band-forming cell. The repeated analysis of Schlieren curves of the same sample from 10 to 100 microL in the 60-100 min full-speed interval time resulted in quite reproducible results. We obtained quantitative results by measuring the Schlieren areas between the sample curves and the reference baseline curve by using computerised numerical and graphic techniques. The decomposition of the integrated curve was carried out using a nonlinear regression program followed by deconvolution algorithm analysis in order to determine the parameters of the composing Gaussian subclasses. The LDL particle concentrations were calculated from the area under the integral of the Gaussian curve using a calibration data constant. The flotation range of the LDL Schlieren curves in the cell was identified with serum from which LDL had been removed by means of precipitation reagents and with centrifugation of isolated LDL aliquots. With this technique, we measured the concentration of LDL and analysed its polydispersity without the need for preceding sequential isolation of the LDL. On the basis of the Schlieren curves, the LDL samples were either physically paucidisperse, having a symmetrical peak within a narrow density range, or were polydisperse, showing an asymmetrical pattern distributed over a broader density region. The described method proved to be useful for a clear and immediate visual presentation of the concentration values of the LDL and for the identification of the

  12. Angiographic patterns of carotid-cavernous fistulas

    International Nuclear Information System (INIS)

    Georgieva, G.; Jekova, M.; Genov, P.; Hadjidekov, V.

    2006-01-01

    Full text: The aim of the study is to present our experience in angiographic evaluation of carotid-cavernous fistulas. 8 patients with carotid-cavernous fistula (6 men and 2 women, range of age from 15 to 62) are included in the study out of all undergone cerebral angiography for a four year period (1996 - 2000). All patients underwent CT brain examination, two out of 8 - MRI. Visualization of ipsi- and contra lateral cavernous sinus and ophthalmic vein dilatation are assessed. In all cases the communication between the internal carotid artery and the cavernous sinus has been assessed as direct. Near simultaneous visualization of the home internal carotid artery, the dilated ipsilateral cavernous sinus and dilated superior ophthalmic vein is found in 2 patients, simultaneous visualization of both cavernous sinuses - in two. In 1 patient the early visualization of the cavernous sinus through the fistula enabled visualization of ipsilateral main internal carotid artery from the contra lateral circulation through the communicating arteries.In 1 excessive contralateral cavernous sinus and contralateral superior ophthalmic vein dilatation is detected. In other 1 excessive flow to dilated ipsilateral cavernous sinus lead insufficient circulation in distal vessels. Digital subtraction Angiography remains the most suitable imaging method in carotid-cavernous fistula assessment regarding type of communication and level of following vessels morphology changes

  13. Optical Absorption in Molecular Crystals from Time-Dependent Density Functional Theory

    Science.gov (United States)

    2017-04-23

    Our approach represents a full solid-state calculation, allowing for polarization ef- fects while still capable of capturing inter-molecular dis...AFRL-AFOSR-UK-TR-2017-0030 Optical absorption in molecular crystals from time-dependent density functional theory Leeor Kronik WEIZMANN INSTITUTE OF...from time-dependent density functional theory 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA9550-15-1-0290 5c.  PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S

  14. Out-of-Time-Ordered Density Correlators in Luttinger Liquids.

    Science.gov (United States)

    Dóra, Balázs; Moessner, Roderich

    2017-07-14

    Information scrambling and the butterfly effect in chaotic quantum systems can be diagnosed by out-of-time-ordered (OTO) commutators through an exponential growth and large late time value. We show that the latter feature shows up in a strongly correlated many-body system, a Luttinger liquid, whose density fluctuations we study at long and short wavelengths, both in equilibrium and after a quantum quench. We find rich behavior combining robustly universal and nonuniversal features. The OTO commutators display temperature- and initial-state-independent behavior and grow as t^{2} for short times. For the short-wavelength density operator, they reach a sizable value after the light cone only in an interacting Luttinger liquid, where the bare excitations break up into collective modes. This challenges the common interpretation of the OTO commutator in chaotic systems. We benchmark our findings numerically on an interacting spinless fermion model in 1D and find persistence of central features even in the nonintegrable case. As a nonuniversal feature, the short-time growth exhibits a distance-dependent power.

  15. Part 5: Receiver Operating Characteristic Curve and Area under the Curve

    Directory of Open Access Journals (Sweden)

    Saeed Safari

    2016-04-01

    Full Text Available Multiple diagnostic tools are used by emergency physicians,every day. In addition, new tools are evaluated to obtainmore accurate methods and reduce time or cost of conventionalones. In the previous parts of this educationalseries, we described diagnostic performance characteristicsof diagnostic tests including sensitivity, specificity, positiveand negative predictive values, and likelihood ratios. Thereceiver operating characteristics (ROC curve is a graphicalpresentation of screening characteristics. ROC curve is usedto determine the best cutoff point and compare two or moretests or observers by measuring the area under the curve(AUC. In this part of our educational series, we explain ROCcurve and two methods to determine the best cutoff value.

  16. Atlas of stress-strain curves

    CERN Document Server

    2002-01-01

    The Atlas of Stress-Strain Curves, Second Edition is substantially bigger in page dimensions, number of pages, and total number of curves than the previous edition. It contains over 1,400 curves, almost three times as many as in the 1987 edition. The curves are normalized in appearance to aid making comparisons among materials. All diagrams include metric (SI) units, and many also include U.S. customary units. All curves are captioned in a consistent format with valuable information including (as available) standard designation, the primary source of the curve, mechanical properties (including hardening exponent and strength coefficient), condition of sample, strain rate, test temperature, and alloy composition. Curve types include monotonic and cyclic stress-strain, isochronous stress-strain, and tangent modulus. Curves are logically arranged and indexed for fast retrieval of information. The book also includes an introduction that provides background information on methods of stress-strain determination, on...

  17. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    Science.gov (United States)

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates. Copyright © 2015 Elsevier Inc. All rights

  18. Digital tomosynthesis for evaluating metastatic lung nodules: Nodule visibility, learning curves, and reading times

    International Nuclear Information System (INIS)

    Lee, Kyung Hee; Goo, Jin Mo; Lee, Sang Min; Park, Chang Min; Bahn, Young Eun; Kim, Hyung Jin; Song, Yong Sub; Hwang, Eui Jin

    2015-01-01

    To evaluate nodule visibility, learning curves, and reading times for digital tomosynthesis (DT). We included 80 patients who underwent computed tomography (CT) and DT before pulmonary metastasectomy. One experienced chest radiologist annotated all visible nodules on thin-section CT scans using computer-aided detection software. Two radiologists used CT as the reference standard and retrospectively graded the visibility of nodules on DT. Nodule detection performance was evaluated in four sessions of 20 cases each by six readers. After each session, readers were unblinded to the DT images by revealing the true-positive markings and were instructed to self-analyze their own misreads. Receiver-operating-characteristic curves were determined. Among 414 nodules on CT, 53.3% (221/414) were visible on DT. The main reason for not seeing a nodule on DT was small size (93.3%, < or = 5 mm). DT revealed a substantial number of malignant nodules (84.1%, 143/170). The proportion of malignant nodules among visible nodules on DT was significantly higher (64.7%, 143/221) than that on CT (41.1%, 170/414) (p < 0.001). Area under the curve (AUC) values at the initial session were > 0.8, and the average detection rate for malignant nodules was 85% (210/246). The inter-session analysis of the AUC showed no significant differences among the readers, and the detection rate for malignant nodules did not differ across sessions. A slight improvement in reading times was observed. Most malignant nodules > 5 mm were visible on DT. As nodule detection performance was high from the initial session, DT may be readily applicable for radiology residents and board-certified radiologists.

  19. Digital tomosynthesis for evaluating metastatic lung nodules: Nodule visibility, learning curves, and reading times

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hee; Goo, Jin Mo; Lee, Sang Min; Park, Chang Min; Bahn, Young Eun; Kim, Hyung Jin; Song, Yong Sub; Hwang, Eui Jin [Dept. of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of)

    2015-04-15

    To evaluate nodule visibility, learning curves, and reading times for digital tomosynthesis (DT). We included 80 patients who underwent computed tomography (CT) and DT before pulmonary metastasectomy. One experienced chest radiologist annotated all visible nodules on thin-section CT scans using computer-aided detection software. Two radiologists used CT as the reference standard and retrospectively graded the visibility of nodules on DT. Nodule detection performance was evaluated in four sessions of 20 cases each by six readers. After each session, readers were unblinded to the DT images by revealing the true-positive markings and were instructed to self-analyze their own misreads. Receiver-operating-characteristic curves were determined. Among 414 nodules on CT, 53.3% (221/414) were visible on DT. The main reason for not seeing a nodule on DT was small size (93.3%, < or = 5 mm). DT revealed a substantial number of malignant nodules (84.1%, 143/170). The proportion of malignant nodules among visible nodules on DT was significantly higher (64.7%, 143/221) than that on CT (41.1%, 170/414) (p < 0.001). Area under the curve (AUC) values at the initial session were > 0.8, and the average detection rate for malignant nodules was 85% (210/246). The inter-session analysis of the AUC showed no significant differences among the readers, and the detection rate for malignant nodules did not differ across sessions. A slight improvement in reading times was observed. Most malignant nodules > 5 mm were visible on DT. As nodule detection performance was high from the initial session, DT may be readily applicable for radiology residents and board-certified radiologists.

  20. A Journey Between Two Curves

    Directory of Open Access Journals (Sweden)

    Sergey A. Cherkis

    2007-03-01

    Full Text Available A typical solution of an integrable system is described in terms of a holomorphic curve and a line bundle over it. The curve provides the action variables while the time evolution is a linear flow on the curve's Jacobian. Even though the system of Nahm equations is closely related to the Hitchin system, the curves appearing in these two cases have very different nature. The former can be described in terms of some classical scattering problem while the latter provides a solution to some Seiberg-Witten gauge theory. This note identifies the setup in which one can formulate the question of relating the two curves.

  1. Decay of hollow states in time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, Varun; Bauer, Dieter [Institut fuer Physik, Wismarsche Str. 43-45, Universitaet Rostock, Rostock-18051 (Germany)

    2012-07-01

    Hollow or multiply excited states are inaccessible in time dependent density functional theory (TDDFT) using adiabatic Kohn-Sham potentials. We determine the exact Kohn Sham (KS) potential for doubly excited states in an exactly solvable model Helium atom. The exact single-particle density corresponds to the energetically lowest quasi-stationary state in the exact KS potential. We describe how this exact potential controls the decay by a barrier whose origin is traced back to phase of the exact KS orbital. The potential controls the barrier height and width in order for the density to tunnel out and decay with the same rate as the doubly excited state in the ab initio time-dependent Schroedinger calculation. Instead, adiabatic KS potentials only show direct photoionization but no autoionization. A frequency-dependent linear response kernel would be necessary in order to capture the decay of autoionizing states.

  2. Description of Concrete Creep under Time-Varying Stress Using Parallel Creep Curve

    OpenAIRE

    Park, Yeong-Seong; Lee, Yong-Hak; Lee, Youngwhan

    2016-01-01

    An incremental format of creep model was presented to take account of the development of concrete creep due to loading at different ages. The formulation was attained by introducing a horizontal parallel assumption of creep curves and combining it with the vertical parallel creep curve of the rate of creep method to remedy the disadvantage of the rate of creep method that significantly underestimates the amount of creep strain, regardless of its simple format. Two creep curves were combined b...

  3. Pediatric renovascular hypertension in Thailand: CT angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Visrutaratna, Pannee; Srisuwan, Tanop; Sirivanichai, Chusak [Chiang Mai University, Department of Radiology, Faculty of Medicine, Chiang Mai (Thailand)

    2009-12-15

    Renovascular disease is an uncommon but important cause of hypertension in children. When unrecognized and untreated, renovascular hypertension in children can have serious complications. To review the causes of renovascular hypertension and computed tomography angiographic (CTA) findings in children and adolescents. Twenty-eight CTAs from January 2004 to March 2008 of 23 children and adolescents with hypertension were reviewed for the causes and CTA findings. Nine of the 23 children (39%) had abnormal renal arteries with or without abnormal abdominal aortas. Four of these children had Takayasu arteritis, one had moyamoya disease, and one had median arcuate ligament syndrome. One with chronic pyelonephritis had severe stenosis of the proximal right renal artery. The other two children had renal artery stenosis with a nonspecific cause. One child with a normal abdominal aorta and renal arteries had a right suprarenal mass. On pathological examination a ganglioneuroma was found. CTA can help in diagnosis of renovascular hypertension in children and adolescents. Although CTA is not a screening modality, it is appropriate in some situations. (orig.)

  4. Pediatric renovascular hypertension in Thailand: CT angiographic findings

    International Nuclear Information System (INIS)

    Visrutaratna, Pannee; Srisuwan, Tanop; Sirivanichai, Chusak

    2009-01-01

    Renovascular disease is an uncommon but important cause of hypertension in children. When unrecognized and untreated, renovascular hypertension in children can have serious complications. To review the causes of renovascular hypertension and computed tomography angiographic (CTA) findings in children and adolescents. Twenty-eight CTAs from January 2004 to March 2008 of 23 children and adolescents with hypertension were reviewed for the causes and CTA findings. Nine of the 23 children (39%) had abnormal renal arteries with or without abnormal abdominal aortas. Four of these children had Takayasu arteritis, one had moyamoya disease, and one had median arcuate ligament syndrome. One with chronic pyelonephritis had severe stenosis of the proximal right renal artery. The other two children had renal artery stenosis with a nonspecific cause. One child with a normal abdominal aorta and renal arteries had a right suprarenal mass. On pathological examination a ganglioneuroma was found. CTA can help in diagnosis of renovascular hypertension in children and adolescents. Although CTA is not a screening modality, it is appropriate in some situations. (orig.)

  5. Real-time control of the plasma density profile on ASDEX upgrade

    International Nuclear Information System (INIS)

    Mlynek, Alexander

    2010-01-01

    The tokamak concept currently is the most promising approach to future power generation by controlled thermonuclear fusion. The spatial distribution of the particle density in the toroidally confined fusion plasma is of particular importance. This thesis work therefore focuses on the question as to what extent the shape of the density profile can be actively controlled by a feedback loop in the fusion experiment ASDEX Upgrade. There are basically two essential requirements for such feedback control of the density profile, which has been experimentally demonstrated within the scope of this thesis work: On the one hand, for this purpose the density profile must be continuously calculated under real-time constraints during a plasma discharge. The calculation of the density profile is based on the measurements of a sub-millimeter interferometer, which provides the line-integrated electron density along 5 chords through the plasma. Interferometric density measurements can suffer from counting errors by integer multiples of 2π when detecting the phase difference between a probing and a reference beam. As such measurement errors have severe impact on the reconstructed density profile, one major part of this work consists in the development of new readout electronics for the interferometer, which allows for detection of such measurement errors in real-time with high reliability. A further part of this work is the design of a computer algorithm which reconstructs the spatial distribution of the plasma density from the line-integrated measurements. This algorithm has to be implemented on a computer which communicates the measured data to other computers in real-time, especially to the tokamak control system. On the other hand, a second fundamental requirement for the successful implementation of a feedback controller is the identification of at least one actuator which enables a modification of the density profile. Here, electron cyclotron resonance heating (ECRH) has been

  6. Technological change in energy systems. Learning curves, logistic curves and input-output coefficients

    International Nuclear Information System (INIS)

    Pan, Haoran; Koehler, Jonathan

    2007-01-01

    Learning curves have recently been widely adopted in climate-economy models to incorporate endogenous change of energy technologies, replacing the conventional assumption of an autonomous energy efficiency improvement. However, there has been little consideration of the credibility of the learning curve. The current trend that many important energy and climate change policy analyses rely on the learning curve means that it is of great importance to critically examine the basis for learning curves. Here, we analyse the use of learning curves in energy technology, usually implemented as a simple power function. We find that the learning curve cannot separate the effects of price and technological change, cannot reflect continuous and qualitative change of both conventional and emerging energy technologies, cannot help to determine the time paths of technological investment, and misses the central role of R and D activity in driving technological change. We argue that a logistic curve of improving performance modified to include R and D activity as a driving variable can better describe the cost reductions in energy technologies. Furthermore, we demonstrate that the top-down Leontief technology can incorporate the bottom-up technologies that improve along either the learning curve or the logistic curve, through changing input-output coefficients. An application to UK wind power illustrates that the logistic curve fits the observed data better and implies greater potential for cost reduction than the learning curve does. (author)

  7. Management of the learning curve

    DEFF Research Database (Denmark)

    Pedersen, Peter-Christian; Slepniov, Dmitrij

    2016-01-01

    Purpose – This paper focuses on the management of the learning curve in overseas capacity expansions. The purpose of this paper is to unravel the direct as well as indirect influences on the learning curve and to advance the understanding of how these affect its management. Design...... the dimensions of the learning process involved in a capacity expansion project and identified the direct and indirect labour influences on the production learning curve. On this basis, the study proposes solutions to managing learning curves in overseas capacity expansions. Furthermore, the paper concludes...... with measures that have the potential to significantly reduce the non-value-added time when establishing new capacities overseas. Originality/value – The paper uses a longitudinal in-depth case study of a Danish wind turbine manufacturer and goes beyond a simplistic treatment of the lead time and learning...

  8. Associations between the time of conception and the shape of the lactation curve in early lactation in Norwegian dairy cattle

    DEFF Research Database (Denmark)

    Andersen, Fredrik; Østerås, Olav; Reksen, Olav

    2011-01-01

    This study was carried out to determine if an association exists between the shape of the lactation curve before it is influenced by the event of conception and the time from calving to conception in Norwegian dairy cattle. Lactation curves of Norwegian Red cows during 5 to 42 days in milk (DIM) ...

  9. Analysis of digital subtraction coronary angiography for estimation of flow reserve in critical coronary stenosis

    International Nuclear Information System (INIS)

    Kohtoku, Shinya

    1988-01-01

    To examine the accuracy of digital subtraction angiographic assessment of coronary flow reserve in critical coronary stenosis, time-density curve was obtained from digital subtraction coronary angiograms for myocardial region of interest. Time to peak contrast(TPC) and time constant of the washout exponential curve(T) were measured in 14 patients with stable effort angina pectoris and critical one vessel lesion before and after percutaneous transluminal coronary angioplasty(PTCA). All patients had normal left ventricular ejection fraction (59 ± 7 %) and Tl 201 myocardial image at rest. The values of TPC and T were significantly shortened from 5.4 ± 1.3 to 4.5 ± 1.0 sec (p < 0.02) and from 10.9 ± 3.8 to 5.3 ± 1.3 sec(p < 0.001) after PTCA, respectively. However, in 9 of all patients TPC after PTCA showed approximately the same valued as those before PTCA. In 5 experimental dogs with critical circumflex stenosis, coronary flow(CF;Doppler flow meter) and systolic thickning of the posterior wall(by sonomicrometry) at rest were not different from control, however, contrast media-induced reactive hyperemia was markedly attenuated, accompanied with a significant of T (7.7 ± 4.5 vs 15.8 ± 10.9 sec, p < 0.01) and completely unchanged TPC (both 6.8 sec). With simultaneous tracing of CF and time-density curve, TPC and washout phase corresponded with contrast-induced transient CF reduction and hyperemic phase, respectively. We conclude that T might be more sensitive for estimation of CF is maintained almost normal, such as patients with stable effort angina pectoris having normal left ventricular wall motion at rest. (author)

  10. The history of the Universe is an elliptic curve

    Science.gov (United States)

    Coquereaux, Robert

    2015-06-01

    Friedmann-Lemaître equations with contributions coming from matter, curvature, cosmological constant, and radiation, when written in terms of conformal time u rather than in terms of cosmic time t, can be solved explicitly in terms of standard Weierstrass elliptic functions. The spatial scale factor, the temperature, the densities, the Hubble function, and almost all quantities of cosmological interest (with the exception of t itself) are elliptic functions of u, in particular they are bi-periodic with respect to a lattice of the complex plane, when one takes u complex. After recalling the basics of the theory, we use these explicit expressions, as well as the experimental constraints on the present values of density parameters (we choose for the curvature density a small value in agreement with experimental bounds) to display the evolution of the main cosmological quantities for one real period 2{{ω }r} of conformal time (the cosmic time t ‘never ends’ but it goes to infinity for a finite value {{u}f}\\lt 2{{ω }r} of u). A given history of the Universe, specified by the measured values of present-day densities, is associated with a lattice in the complex plane, or with an elliptic curve, and therefore with two Weierstrass invariants {{g}2},{{g}3}. Using the same experimental data we calculate the values of these invariants, as well as the associated modular parameter and the corresponding Klein j-invariant. If one takes the flat case k = 0, the lattice is only defined up to homotheties, and if one, moreover, neglects the radiation contribution, the j-invariant vanishes and the corresponding modular parameter τ can be chosen in one corner of the standard fundamental domain of the modular group (equihanharmonic case: τ =exp (2iπ /3)). Several exact—i.e., non-numerical—results of independent interest are obtained in that case.

  11. Timing of Hormone Therapy, Type of Menopause, and Coronary Disease in Women: Data from the NHLBI-sponsored Women’s Ischemia Syndrome Evaluation (WISE)

    Science.gov (United States)

    Shufelt, Chrisandra; Johnson, B. Delia; Berga, Sarah L.; Braunstein, Glenn D.; Reis, Steven E.; Bittner, Vera; Yang, YuChing; Pepine, Carl J.; Sharaf, Barry L.; Sopko, George; Kelsey, Sheryl F.; Merz, C. Noel Bairey

    2011-01-01

    Objective To assess the relationship of timing of hormone therapy (HT) use with angiographic coronary artery disease (CAD) and cardiovascular disease (CVD) events in women with natural versus surgical menopause. Methods We studied 654 postmenopausal women undergoing coronary angiography for evaluation of suspected ischemia. Timing and type of menopause, HT use, and quantitative angiographic evaluations were obtained at baseline, and the women were followed for a median of 6 years for CVD events. Results Ever users of HT had a significantly lower prevalence of obstructive CAD compared to never users (age-adjusted OR=0.41 [0.28, 0.60]). Naturally menopausal women initiating HT at age menopause group (HR [95%CI] = 0.60[0.41, 0.88], p=0.009) but became non-significant when adjusting for presence or severity of obstructive CAD. Conclusions Using quantitative measurements of timing and type of menopause and HT use, earlier initiation of HT was associated with less angiographic CAD in women with natural but not surgical menopause. Our data suggest that the effect of HT use on reduced cardiovascular event rates is mediated by the presence or absence of angiographic obstructive atherosclerosis. PMID:21532511

  12. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion.

    Science.gov (United States)

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-12-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed cerebral angiography of 7 patients (4 hyaluronic acid [HA] and 3 autologous fat-injected cases) showing ophthalmic artery and its branches occlusion after cosmetic facial filler injections, and underwent intra-arterial thrombolysis. On selective ophthalmic artery angiograms, all fat-injected patients showed a large filling defect on the proximal ophthalmic artery, whereas the HA-injected patients showed occlusion of the distal branches of the ophthalmic artery. Three HA-injected patients revealed diminished distal runoff of the internal maxillary and facial arteries, which clinically corresponded with skin necrosis. However, all fat-injected patients and one HA-injected patient who were immediately treated with subcutaneous hyaluronidase injection showed preserved distal runoff of the internal maxillary and facial arteries and mild skin problems. The size difference between injected materials seems to be associated with different angiographic findings. Autologous fat is more prone to obstruct proximal part of ophthalmic artery, whereas HA obstructs distal branches. In addition, hydrophilic and volume-expansion property of HA might exacerbate blood flow on injected area, which is also related to skin necrosis. Intra-arterial thrombolysis has a limited role in reconstituting blood flow or regaining vision in cosmetic facial filler-associated ophthalmic artery occlusions.

  13. Aspects of quantum field theory in curved space-time

    CERN Document Server

    Fulling, Stephen A

    1989-01-01

    The theory of quantum fields on curved spacetimes has attracted great attention since the discovery, by Stephen Hawking, of black-hole evaporation. It remains an important subject for the understanding of such contemporary topics as inflationary cosmology

  14. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis.

    Science.gov (United States)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-12-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  15. Probe initial parton density and formation time via jet quenching

    International Nuclear Information System (INIS)

    Wang, Xin-Nian

    2002-01-01

    Medium modification of jet fragmentation function due to multiple scattering and induced gluon radiation leads directly to jet quenching or suppression of leading particle distribution from jet fragmentation. One can extract an effective total parton energy loss which can be related to the total transverse momentum broadening. For an expanding medium, both are shown to be sensitive to the initial parton density and formation time. Therefore, one can extract the initial parton density and formation time from simultaneous measurements of parton energy loss and transverse momentum broadening. Implication of the recent experimental data on effects of detailed balance in parton energy loss is also discussed

  16. Application of Hill's equation for estimating area under the concentration-time curve (AUC) and use of time to AUC 90% for expressing kinetics of drug disposition.

    Science.gov (United States)

    Cheng, Hsien C

    2009-01-01

    Half life and its derived pharmacokinetic parameters are calculated on an assumption that the terminal phase of drug disposition follows a constant rate of disposition. In reality, this assumption may not necessarily be the case. A new method is needed for analyzing PK parameters if the disposition does not follow a first order PK kinetic. Cumulative area under the concentration-time curve (AUC) is plotted against time to yield a hyperbolic (or sigmoidal) AUC-time relationship curve which is then analyzed by Hill's equation to yield AUC(inf), time to achieving AUC50% (T(AUC50%)) or AUC90% (T(AUC90%)), and the Hill's slope. From these parameters, an AUC-time relationship curve can be reconstructed. Projected plasma concentration can be calculated for any time point. Time at which cumulative AUC reaches 90% (T(AUC90%)) can be used as an indicator for expressing how fast a drug is cleared. Clearance is calculated in a traditional manner (i.v. dose/AUC(inf)), and the volume of distribution is proposed to be calculated at T(AUC50%) (0.5 i.v. dose/plasma concentration at T(AUC50%)). This method of estimating AUC is applicable for both i.v. and oral data. It is concluded that the Hill's equation can be used as an alternative method for estimating AUC and analysis of PK parameters if the disposition does not follow a first order kinetic. T(AUC90%) is proposed to be used as an indicator for expressing how fast a drug is cleared from the system.

  17. Real-time defect detection on highly reflective curved surfaces

    Science.gov (United States)

    Rosati, G.; Boschetti, G.; Biondi, A.; Rossi, A.

    2009-03-01

    This paper presents an automated defect detection system for coated plastic components for the automotive industry. This research activity came up as an evolution of a previous study which employed a non-flat mirror to illuminate and inspect high reflective curved surfaces. According to this method, the rays emitted from a light source are conveyed on the surface under investigation by means of a suitably curved mirror. After the reflection on the surface, the light rays are collected by a CCD camera, in which the coating defects appear as shadows of various shapes and dimensions. In this paper we present an evolution of the above-mentioned method, introducing a simplified mirror set-up in order to reduce the costs and the complexity of the defect detection system. In fact, a set of plane mirrors is employed instead of the curved one. Moreover, the inspection of multiple bend radius parts is investigated. A prototype of the machine vision system has been developed in order to test this simplified method. This device is made up of a light projector, a set of plane mirrors for light rays reflection, a conveyor belt for handling components, a CCD camera and a desktop PC which performs image acquisition and processing. Like in the previous system, the defects are identified as shadows inside a high brightness image. At the end of the paper, first experimental results are presented.

  18. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  19. Nonlocal and Nonadiabatic Effects in the Charge-Density Response of Solids: A Time-Dependent Density-Functional Approach

    Science.gov (United States)

    Panholzer, Martin; Gatti, Matteo; Reining, Lucia

    2018-04-01

    The charge-density response of extended materials is usually dominated by the collective oscillation of electrons, the plasmons. Beyond this feature, however, intriguing many-body effects are observed. They cannot be described by one of the most widely used approaches for the calculation of dielectric functions, which is time-dependent density functional theory (TDDFT) in the adiabatic local density approximation (ALDA). Here, we propose an approximation to the TDDFT exchange-correlation kernel which is nonadiabatic and nonlocal. It is extracted from correlated calculations in the homogeneous electron gas, where we have tabulated it for a wide range of wave vectors and frequencies. A simple mean density approximation allows one to use it in inhomogeneous materials where the density varies on a scale of 1.6 rs or faster. This kernel contains effects that are completely absent in the ALDA; in particular, it correctly describes the double plasmon in the dynamic structure factor of sodium, and it shows the characteristic low-energy peak that appears in systems with low electronic density. It also leads to an overall quantitative improvement of spectra.

  20. Learning Curve? Which One?

    Directory of Open Access Journals (Sweden)

    Paulo Prochno

    2004-07-01

    Full Text Available Learning curves have been studied for a long time. These studies provided strong support to the hypothesis that, as organizations produce more of a product, unit costs of production decrease at a decreasing rate (see Argote, 1999 for a comprehensive review of learning curve studies. But the organizational mechanisms that lead to these results are still underexplored. We know some drivers of learning curves (ADLER; CLARK, 1991; LAPRE et al., 2000, but we still lack a more detailed view of the organizational processes behind those curves. Through an ethnographic study, I bring a comprehensive account of the first year of operations of a new automotive plant, describing what was taking place on in the assembly area during the most relevant shifts of the learning curve. The emphasis is then on how learning occurs in that setting. My analysis suggests that the overall learning curve is in fact the result of an integration process that puts together several individual ongoing learning curves in different areas throughout the organization. In the end, I propose a model to understand the evolution of these learning processes and their supporting organizational mechanisms.

  1. Dipyridamole-induced ST segment depression during thallium-201 imaging in patients with coronary artery disease: angiographic and hemodynamic determinants

    International Nuclear Information System (INIS)

    Chambers, C.E.; Brown, K.A.

    1988-01-01

    To examine the angiographic and hemodynamic determinants of dipyridamole-induced ST segment depression in patients with coronary artery disease, 41 patients with angiographically documented coronary disease who underwent dipyridamole-thallium-201 myocardial scintigraphy were studied. Dipyridamole-induced ST depression occurred in 14 (34%) of the 41 patients. Stepwise multivariate logistic regression was performed to compare the predictive value of angiographic findings (good coronary collateral vessels, jeopardized collateral vessels, multivessel disease), hemodynamic changes (changes in heart rate, systolic pressure, diastolic pressure and rate-pressure product), thallium-201 results (perfusion defect, thallium-201 redistribution) and demographic data (age, gender, medications). Only the presence of good coronary collateral vessels (p less than 0.02) and increases in rate-pressure product after dipyridamole infusion (p less than 0.02) were significant multivariate predictors of dipyridamole-induced ST depression. Good collateral vessels were more common in the group with ST depression (11 [79%] of 14) than they were in the group without ST depression (6 [22%] of 27; p less than 0.001). Rate-pressure product increased 2,835 +/- 1,648 beats/min.mm Hg in the group with ST depression compared with 1,179 +/- 1,417 beats/min.mm Hg in patients without ST depression (p less than 0.005). In conclusion, dipyridamole-induced ST segment depression in patients with coronary artery disease appears to be related to 1) the presence of good coronary collateral vessels, which may act by facilitating coronary steal, and 2) increases in rate-pressure product, reflecting increased myocardial oxygen demand. These observations may explain the lack of prognostic value of dipyridamole-induced ST segment depression described in previous reports

  2. Radionuclide angiography in graded carotoid stenosis. An experimental study with angiographic correlation

    International Nuclear Information System (INIS)

    Weissman, B.N.; Holman, B.L.; Rosenbaum, A.E.

    1975-01-01

    Radionuclide and contrast angiographies were performed in 10 dogs. In 6 dogs unilateral or bilateral (partial or total) carotid occlusions were produced by silk ligatures. Follow-up angiographies were carried out at intervals up to 6 months following surgery. Visual assessment of the radionuclide carotid angiogram was compared to quantitative analysis of the time-activity curves over these areas. Several parameters of these curves were reviewed. The ratio of the slopes was the most sensitive parameter of the assessment of carotid artery stenosis. The ratio of the slopes of the curves in normal dogs (mean 96 +- 5.2 S.D.) was significantly different from that in animals with stenosis greater than 80 percent (mean 67.3 +- 16.9 S.D.). (U.S.)

  3. Universal time dependence of nighttime F region densities at high latitudes

    International Nuclear Information System (INIS)

    Beaujardiere, O.D.L.; Wickwar, V.B.; Caudal, G.

    1985-01-01

    Coordinated EISCAT, Chatanika, and Millstone Hill incoherent scatter radar observations have revealed that in the auroral zone, the nighttime F region densities vary substantially with the longitude of the observing site: EISCAT's densities are the largest and Millstone Hill's are the lowest. The nighttime F region densities measured by the individual radars are not uniform: the regions where the densities are maximum are the so-called ''blobs'' or ''patches'' that have been reported previously. The observations are consistent with the hypothesis that the nighttime densities are produced in significant amounts not by particle precipitation, but by solar EUV radiation, and that they have been transported across the polar cap. The observed differences can be explained by the offset of the geographic and geomagnetic poles. A larger portion of the magnetospheric convection pattern is sunlit when EISCAT is in the midnight sector than when Chatanika is. In winter, when Millstone Hill is in the midnight sector, almost all the auroral oval is in darkness. This universal time effect, which was observed on all coordinated three-radar experiments (September 1981 to February 1982), is illustrated using two periods of coincident radar and satellite observations: November 18--19, and December 15--16, 1981. These two periods were selected because they corresponded to relatively steady conditions. Dynamics Explorer (DE) measurements are used to aid in interpreting the radar observations. De 1 auroral images show what portion of the oval was sunlit. DE 2 data are used to measure the ion drift across the polar cap. Because the altitude of the ionization peak was high, the decay time of the F region density was substantially longer than the transit time across the polar cap

  4. The curve shortening problem

    CERN Document Server

    Chou, Kai-Seng

    2001-01-01

    Although research in curve shortening flow has been very active for nearly 20 years, the results of those efforts have remained scattered throughout the literature. For the first time, The Curve Shortening Problem collects and illuminates those results in a comprehensive, rigorous, and self-contained account of the fundamental results.The authors present a complete treatment of the Gage-Hamilton theorem, a clear, detailed exposition of Grayson''s convexity theorem, a systematic discussion of invariant solutions, applications to the existence of simple closed geodesics on a surface, and a new, almost convexity theorem for the generalized curve shortening problem.Many questions regarding curve shortening remain outstanding. With its careful exposition and complete guide to the literature, The Curve Shortening Problem provides not only an outstanding starting point for graduate students and new investigations, but a superb reference that presents intriguing new results for those already active in the field.

  5. Methods for predicting isochronous stress-strain curves

    International Nuclear Information System (INIS)

    Kiyoshige, Masanori; Shimizu, Shigeki; Satoh, Keisuke.

    1976-01-01

    Isochronous stress-strain curves show the relation between stress and total strain at a certain temperature with time as a parameter, and they are drawn up from the creep test results at various stress levels at a definite temperature. The concept regarding the isochronous stress-strain curves was proposed by McVetty in 1930s, and has been used for the design of aero-engines. Recently the high temperature characteristics of materials are shown as the isochronous stress-strain curves in the design guide for the nuclear energy equipments and structures used in high temperature creep region. It is prescribed that these curves are used as the criteria for determining design stress intensity or the data for analyzing the superposed effects of creep and fatigue. In case of the isochronous stress-strain curves used for the design of nuclear energy equipments with very long service life, it is impractical to determine the curves directly from the results of long time creep test, accordingly the method of predicting long time stress-strain curves from short time creep test results must be established. The method proposed by the authors, for which the creep constitution equations taking the first and second creep stages into account are used, and the method using Larson-Miller parameter were studied, and it was found that both methods were reliable for the prediction. (Kako, I.)

  6. Bond yield curve construction

    Directory of Open Access Journals (Sweden)

    Kožul Nataša

    2014-01-01

    Full Text Available In the broadest sense, yield curve indicates the market's view of the evolution of interest rates over time. However, given that cost of borrowing it closely linked to creditworthiness (ability to repay, different yield curves will apply to different currencies, market sectors, or even individual issuers. As government borrowing is indicative of interest rate levels available to other market players in a particular country, and considering that bond issuance still remains the dominant form of sovereign debt, this paper describes yield curve construction using bonds. The relationship between zero-coupon yield, par yield and yield to maturity is given and their usage in determining curve discount factors is described. Their usage in deriving forward rates and pricing related derivative instruments is also discussed.

  7. Time dependent density matrix theory and effective interaction

    Energy Technology Data Exchange (ETDEWEB)

    Tohyama, Mitsuru [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-07-01

    A correlated ground state of {sup 16}O and an E2 giant resonance built on it are calculated using an extended version of the time-dependent Hartree-Fock theory called the time-dependent density-matrix theory (TDDM). The Skyrme force is used in the calculation of both a mean field and two-body correlations. It is found that TDDM gives reasonable ground-state correlations and a large spreading width of the E2 giant resonance when single-particle states in the continuum are treated appropriately. (author)

  8. The redshift number density evolution of Mg II absorption systems

    International Nuclear Information System (INIS)

    Chen Zhi-Fu

    2013-01-01

    We make use of the recent large sample of 17 042 Mg II absorption systems from Quider et al. to analyze the evolution of the redshift number density. Regardless of the strength of the absorption line, we find that the evolution of the redshift number density can be clearly distinguished into three different phases. In the intermediate redshift epoch (0.6 ≲ z ≲ 1.6), the evolution of the redshift number density is consistent with the non-evolution curve, however, the non-evolution curve over-predicts the values of the redshift number density in the early (z ≲ 0.6) and late (z ≳ 1.6) epochs. Based on the invariant cross-section of the absorber, the lack of evolution in the redshift number density compared to the non-evolution curve implies the galaxy number density does not evolve during the middle epoch. The flat evolution of the redshift number density tends to correspond to a shallow evolution in the galaxy merger rate during the late epoch, and the steep decrease of the redshift number density might be ascribed to the small mass of halos during the early epoch.

  9. Contrast-enhanced transrectal ultrasound for prediction of prostate cancer aggressiveness: The role of normal peripheral zone time-intensity curves.

    Science.gov (United States)

    Huang, Hui; Zhu, Zheng-Qiu; Zhou, Zheng-Guo; Chen, Ling-Shan; Zhao, Ming; Zhang, Yang; Li, Hong-Bo; Yin, Li-Ping

    2016-12-08

    To assess the role of time-intensity curves (TICs) of the normal peripheral zone (PZ) in the identification of biopsy-proven prostate nodules using contrast-enhanced transrectal ultrasound (CETRUS). This study included 132 patients with 134 prostate PZ nodules. Arrival time (AT), peak intensity (PI), mean transit time (MTT), area under the curve (AUC), time from peak to one half (TPH), wash in slope (WIS) and time to peak (TTP) were analyzed using multivariate linear logistic regression and receiver operating characteristic (ROC) curves to assess whether combining nodule TICs with normal PZ TICs improved the prediction of prostate cancer (PCa) aggressiveness. The PI, AUC (p < 0.001 for both), MTT and TPH (p = 0.011 and 0.040 respectively) values of the malignant nodules were significantly higher than those of the benign nodules. Incorporating the PI and AUC values (both, p < 0.001) of the normal PZ TIC, but not the MTT and TPH values (p = 0.076 and 0.159 respectively), significantly improved the AUC for prediction of malignancy (PI: 0.784-0.923; AUC: 0.758-0.891) and assessment of cancer aggressiveness (p < 0.001). Thus, all these findings indicate that incorporating normal PZ TICs with nodule TICs in CETRUS readings can improve the diagnostic accuracy for PCa and cancer aggressiveness assessment.

  10. Stationary solution of a time dependent density matrix formalism

    International Nuclear Information System (INIS)

    Tohyama, Mitsuru

    1994-01-01

    A stationary solution of a time-dependent density-matrix formalism, which is an extension of the time-dependent Hartree-Fock theory to include the effects of two-body correlations, is obtained for the Lipkin model hamiltonian, using an adiabatic treatment of the two-body interaction. It is found that the obtained result is a reasonable approximation for the exact solution of the model. (author)

  11. Hyper-and-elliptic-curve cryptography

    NARCIS (Netherlands)

    Bernstein, D.J.; Lange, T.

    2014-01-01

    This paper introduces ‘hyper-and-elliptic-curve cryptography’, in which a single high-security group supports fast genus-2-hyperelliptic-curve formulas for variable-base-point single-scalar multiplication (for example, Diffie–Hellman shared-secret computation) and at the same time supports fast

  12. Developing an optimal valve closing rule curve for real-time pressure control in pipes

    Energy Technology Data Exchange (ETDEWEB)

    Bazarganlari, Mohammad Reza; Afshar, Hossein [Islamic Azad University, Tehran (Iran, Islamic Republic of); Kerachian, Reza [University of Tehran, Tehran (Iran, Islamic Republic of); Bashiazghadi, Seyyed Nasser [Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2013-01-15

    Sudden valve closure in pipeline systems can cause high pressures that may lead to serious damages. Using an optimal valve closing rule can play an important role in managing extreme pressures in sudden valve closure. In this paper, an optimal closing rule curve is developed using a multi-objective optimization model and Bayesian networks (BNs) for controlling water pressure in valve closure instead of traditional step functions or single linear functions. The method of characteristics is used to simulate transient flow caused by valve closure. Non-dominated sorting genetic algorithms-II is also used to develop a Pareto front among three objectives related to maximum and minimum water pressures, and the amount of water passes through the valve during the valve-closing process. Simulation and optimization processes are usually time-consuming, thus results of the optimization model are used for training the BN. The trained BN is capable of determining optimal real-time closing rules without running costly simulation and optimization models. To demonstrate its efficiency, the proposed methodology is applied to a reservoir-pipe-valve system and the optimal closing rule curve is calculated for the valve. The results of the linear and BN-based valve closure rules show that the latter can significantly reduce the range of variations in water hammer pressures.

  13. Mechanical energy yields and pressure volume and pressure time curves for whole core fuel-coolant interactions

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, P [United Kingdom Atomic Energy Authority, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1979-10-15

    In determining the damage consequences of a whole core Fuel-Coolant Interaction (FCI), one measure of the strength of a FCI that can be used and is independent of the system geometry is the constant volume mixing mechanical yield (often referred to as the Hicks-Menzies yield), which represents a near upper limit to the mechanical work of a FCI. This paper presents a recalculation of the Hicks-Menzies yields for UO{sub 2} and sodium for a range of initial fuel temperatures and fuel to coolant mass ratios, using recently published UO{sub 2} and sodium equation of state data. The work presented here takes a small number of postulated FCIs with as wide range as possible of thermal interaction parameters and determines their pressure-volume P(V) and pressure-time P(t) relations, using geometrical constraints representative of the reactor. Then by examining these P(V) and P(t) curves a representative pressure-relative volume curve or range of possible curves, for use in containment analysis, is recommended

  14. Angiographic follow-up after carotid artery stenting of bifurcation stenosis; Angiographische Verlaufskontrolle nach Stentimplantation zur Behandlung der Karotisbifurkationsstenose

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, E.A.; Forsting, M. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Jansen, C.; Drescher, R.; Mathias, K. [Radiologische Klinik, Klinikum Dortmund (Germany); Schwarz, M. [Neurologische Klinik, Klinikum Dortmund (Germany); Christmann, A. [Fachbereich Statistik, Univ. Dortmund (Germany); Jaeger, H. [Radiologische Klinik, Klinikum Dortmund (Germany); Marien-Hospital Wesel, Praxis fuer Radiologie, Neuroradiologie and Nuklearmedizin (Germany)

    2006-08-15

    Purpose: the purpose of this prospective study was to determine the restenosis grade, the intima hyperplasia and the stent expansion via angiographic follow-up six months after carotid artery stenting. Materials and methods: in 100 patients, angiographic follow-up was performed 5.9 months (range: 2.9 - 11.4 months) after carotid artery stenting. The restenosis grade, the intima hyperplasia and the stent expansion were measured by selective angiography of the treated carotid artery. Results: the mean restenosis grade was 16% (range: 0 - 78%). In 6 of 100 patients (6%), a restenosis grade of > 50% was measured. In 4 patients the restenosis grade was 50 - 70%. In 2 patients the restenosis grade was > 70%. In 91 of 100 patients (91%), the restenosis was localized in the former area of stenosis of the carotid artery, and in 9 of 100 patients (9%), the restenosis was localized in the cranial stent end. The mean grade of intima hyperplasia was 31% (range: 2 - 70%). The mean increase in stent expansion at the time of follow-up was 10% (range: 0 - 59%). No correlation was able to be determined between the grade of stenosis and the grade of restenosis (rho = 0,017, range: -0.180 - 0.213), between the grade of residual stenosis and the grade of restenosis (rho = 0,257, range: 0.064 - 0.431) and between intima hyperplasia and the grade of restenosis (rho = 0,476, range: 0.309 - 0.615). Conclusions: carotid artery stenting is associated with a low incidence of high-grade restenosis 6 months after an intervention. The intima hyperplasia, which can be observed in each Wallstent, is partly compensated by the expansion of the self-expandable stent. Without a correlation between the grade of residual stenosis and the grade of restenosis, low-grade residual stenosis can be accepted. Therefore, we recommend undersized postdilation of the Wallstent. (orig.)

  15. Pneumococcal Serotypes Colonise the Nasopharynx in Children at Different Densities.

    Directory of Open Access Journals (Sweden)

    Fernanda Rodrigues

    Full Text Available Prevalence of pneumococcal serotypes in carriage and disease has been described but absolute serotype colonisation densities have not been reported. 515 paediatric nasal swab DNA extracts were subjected to lytA qPCR and molecular serotyping by microarray. Absolute serotype densities were derived from total pneumococcal density (qPCR cycle threshold and standard curve and relative abundance (microarray and varied widely. Compared to all serotype densities observed, the strongest evidence of differences was seen for serotypes 21 and 35B (higher and 3, 38 and non-typeables (lower (p<0.05 with a similar hierarchy when only a single serotype carriage was assessed. There was no evidence of any overall density differences between children with single or multiple serotypes detected but serotypes with mid-range densities were more prevalent. The hierarchy of distinct pneumococcal serotype carriage densities described here for the first time, may help explain the dynamics of transmission between children.

  16. Pelvic Arterial Anatomy Relevant to Prostatic Artery Embolisation and Proposal for Angiographic Classification

    Energy Technology Data Exchange (ETDEWEB)

    Assis, André Moreira de, E-mail: andre.maa@gmail.com; Moreira, Airton Mota, E-mail: motamoreira@gmail.com; Paula Rodrigues, Vanessa Cristina de, E-mail: vanessapaular@yahoo.com.br [University of Sao Paulo Medical School, Interventional Radiology and Endovascular Surgery Department, Radiology Institute (Brazil); Harward, Sardis Honoria, E-mail: sardis.harward@merit.com [The Dartmouth Center for Health Care Delivery Science (United States); Antunes, Alberto Azoubel, E-mail: antunesuro@uol.com.br; Srougi, Miguel, E-mail: srougi@usp.br [University of Sao Paulo Medical School, Urology Department (Brazil); Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br [University of Sao Paulo Medical School, Interventional Radiology and Endovascular Surgery Department, Radiology Institute (Brazil)

    2015-08-15

    PurposeTo describe and categorize the angiographic findings regarding prostatic vascularization, propose an anatomic classification, and discuss its implications for the PAE procedure.MethodsAngiographic findings from 143 PAE procedures were reviewed retrospectively, and the origin of the inferior vesical artery (IVA) was classified into five subtypes as follows: type I: IVA originating from the anterior division of the internal iliac artery (IIA), from a common trunk with the superior vesical artery (SVA); type II: IVA originating from the anterior division of the IIA, inferior to the SVA origin; type III: IVA originating from the obturator artery; type IV: IVA originating from the internal pudendal artery; and type V: less common origins of the IVA. Incidences were calculated by percentage.ResultsTwo hundred eighty-six pelvic sides (n = 286) were analyzed, and 267 (93.3 %) were classified into I–IV types. Among them, the most common origin was type IV (n = 89, 31.1 %), followed by type I (n = 82, 28.7 %), type III (n = 54, 18.9 %), and type II (n = 42, 14.7 %). Type V anatomy was seen in 16 cases (5.6 %). Double vascularization, defined as two independent prostatic branches in one pelvic side, was seen in 23 cases (8.0 %).ConclusionsDespite the large number of possible anatomical variations of male pelvis, four main patterns corresponded to almost 95 % of the cases. Evaluation of anatomy in a systematic fashion, following a standard classification, will make PAE a faster, safer, and more effective procedure.

  17. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    International Nuclear Information System (INIS)

    Kjeldsen, Henrik; Heinemeier, Jan; Heegaard, Steffen; Jacobsen, Christina; Lynnerup, Niels

    2010-01-01

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth, in accordance with expectations. Moreover, it has been possible to develop an age model for the formation of the eye-lens crystallines. From this model a radiocarbon calibration curve for lens crystallines has been calculated. As a consequence, the time of birth of humans can be determined with an accuracy of a few years by radiocarbon dating.

  18. Dating the time of birth: A radiocarbon calibration curve for human eye-lens crystallines

    Energy Technology Data Exchange (ETDEWEB)

    Kjeldsen, Henrik, E-mail: kjeldsen@phys.au.d [AMS 14C Dating Centre, Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark); Heinemeier, Jan [AMS 14C Dating Centre, Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark); Heegaard, Steffen [Eye Pathology Section, Department of Neuroscience and Pharmacology, University of Copenhagen, Copenhagen (Denmark); Jacobsen, Christina; Lynnerup, Niels [Department of Forensic Medicine, University of Copenhagen, Copenhagen (Denmark)

    2010-04-15

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth, in accordance with expectations. Moreover, it has been possible to develop an age model for the formation of the eye-lens crystallines. From this model a radiocarbon calibration curve for lens crystallines has been calculated. As a consequence, the time of birth of humans can be determined with an accuracy of a few years by radiocarbon dating.

  19. Right ventricular ejection fraction - comparison of various angiographic and radionuclide approaches

    International Nuclear Information System (INIS)

    Schicha, H.; Tebbe, U.; Voth, E.; Sciagra, R.; Schultz, W.; Neuhaus, G.; Goettingen Univ.

    1987-01-01

    In 21 patients with various heart diseases RVEF was measured angiographically and by radionuclide ventriculography. Using biplane angiocardiography evaluation was performed by 7 different methods (Simpson's rule, Dogde, Arcilla, Ferlinz, Duebel). Using equilibrium RNV, evaluation was performed by 9 modifications of analysis. Problems were evident to separate the right atrium from the ventricle and to define the site of the pulmonary valve. The results show that when using the various methods of angiography considerable variations of the absolute volumes occur, but least so with RVEF. When using RNV with one single enddiastolic ROI, the RVEF was much too low. By means of the enddiastolic/endsystolic Double-ROI-method a good agreement with angiography was found, with correlation coefficients up to r=0.85. There was only a minor effect of background correction. (orig.) [de

  20. Direct numerical simulation of axisymmetric laminar low-density jets

    Science.gov (United States)

    Gomez Lendinez, Daniel; Coenen, Wilfried; Sevilla, Alejandro

    2017-11-01

    The stability of submerged laminar axisymmetric low-density jets has been investigated experimentally (Kyle & Sreenivasan 1993, Hallberg & Strykowski 2006) and with linear analysis (Jendoubi & Strykowski 1994, Coenen & Sevilla 2012, Coenen et al. 2017). These jets become globally unstable when the Reynolds number is larger than a certain critical value which depends on the density ratio and on the velocity profile at the injector outlet. In this work, Direct Numerical Simulations using FreeFEM + + (Hecht 2012) with P1 elements for pressure and P2 for velocity and density are performed to complement the above mentioned studies. Density and velocity fields are analyzed at long time showing the unforced space-time evolution of nonlinear disturbances propagating along the jet. Using the Stuart-Landau model to fit the numerical results for the self-excited oscillations we have computed a neutral stability curve that shows good agreement with experiments and stability theory. Thanks to Spanish MINECO under projects DPI2014-59292-C3-1-P and DPI2015-71901-REDT for financial support.

  1. Large-strain time-temperature equivalence in high density polyethylene for prediction of extreme deformation and damage

    Directory of Open Access Journals (Sweden)

    Gray G.T.

    2012-08-01

    Full Text Available Time-temperature equivalence is a widely recognized property of many time-dependent material systems, where there is a clear predictive link relating the deformation response at a nominal temperature and a high strain-rate to an equivalent response at a depressed temperature and nominal strain-rate. It has been found that high-density polyethylene (HDPE obeys a linear empirical formulation relating test temperature and strain-rate. This observation was extended to continuous stress-strain curves, such that material response measured in a load frame at large strains and low strain-rates (at depressed temperatures could be translated into a temperature-dependent response at high strain-rates and validated against Taylor impact results. Time-temperature equivalence was used in conjuction with jump-rate compression tests to investigate isothermal response at high strain-rate while exluding adiabatic heating. The validated constitutive response was then applied to the analysis of Dynamic-Tensile-Extrusion of HDPE, a tensile analog to Taylor impact developed at LANL. The Dyn-Ten-Ext test results and FEA found that HDPE deformed smoothly after exiting the die, and after substantial drawing appeared to undergo a pressure-dependent shear damage mechanism at intermediate velocities, while it fragmented at high velocities. Dynamic-Tensile-Extrusion, properly coupled with a validated constitutive model, can successfully probe extreme tensile deformation and damage of polymers.

  2. Angiographic examinations with the medium size technique (70 mm films)

    International Nuclear Information System (INIS)

    Heuck, F.; Reichardt, W.

    1981-01-01

    The applicability of medium-size technique was tested in angiographic examinations of thoracic and abdominal organs. By means of full-size image intensifiers it is possible to carry out organ angiography, and by means of a pace control mechanism for the patient transport, the angiography of the extremities can be realized. Examples are given illustrate the informational value in cases where the arial and venous vascular systems of organs and extremities are concerned. The particular advantages for functional analyses of organ circulatory systems in cases of angiography are described. Two factors of importance are pointed out: the reduction of the exposure to irradiation for the patient on the one hand, and the increasing film prices on the other hand. The authors demand to overcome the psychological problems arising in the medical working groups where the medium-size technique shall be introduced into routine diagnostics. (orig./APR) [de

  3. Angiographic prevalence and pattern of coronary artery disease in women.

    Science.gov (United States)

    Ezhumalai, Babu; Jayaraman, Balachander

    2014-01-01

    There are not many studies describing the prevalence and pattern of "coronary artery disease" (CAD) in women undergoing "coronary angiography" (CAG). Hence, uncertainty thrives with regard to the angiographic prevalence and pattern of CAD in women. Our objective was to study the prevalence and pattern of CAD among women undergoing CAG. Data of 500 women who underwent CAG for suspected CAD over 3 years were retrospectively analyzed. They were classified into young group (age right coronary artery. Bifurcation lesion involving distal left main coronary artery is the most prevalent pattern of LMD. There has been a change with regard to clinical presentation and onset of risk factors for CAD at young age, but the load of atherosclerotic burden and pattern of involvement of coronary arteries have not changed in women. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  4. Plasma flow in a curved magnetic field

    International Nuclear Information System (INIS)

    Lindberg, L.

    1977-09-01

    A beam of collisionless plasma is injected along a longitudinal magnetic field into a region of curved magnetic field. Two unpredicted phenomena are observed: The beam becomes deflected in the direction opposite to that in which the field is curved, and it contracts to a flat slab in the plane of curvature of the magnetic field. The phenomenon is of a general character and can be expected to occur in a very wide range of densities. The lower density limit is set by the condition for self-polarization, nm sub(i)/epsilon 0 B 2 >> 1 or, which is equivalent, c 2 /v 2 sub(A) >> 1, where c is the velocity of light, and v sup(A) the Alfven velocity. The upper limit is presumably set by the requirement ωsub(e)tau(e) >> 1. The phenomenon is likely to be of importance e.g. for injection of plasma into magnetic bottles and in space and solar physics. The paper illustrates the comlexity of plasma flow phenomena and the importance of close contact between experimental and theoretical work. (author)

  5. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jang Hyun; Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  6. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    International Nuclear Information System (INIS)

    Baek, Jang Hyun; Kim, Byung Moon

    2015-01-01

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  7. Geometro-stochastic quantization of gauge fields in curved space-time

    International Nuclear Information System (INIS)

    Prugovecki, E.

    1988-01-01

    It is shown that the geometro-stochastic method of quantization of massive fields in curved space-time can be extended to the massless cases of electromagnetic fields and general Yang-Mills fields. The Fock fibres of the massive case are replaced in the present context by fibres with indefinite inner products, such as Gupta-Bleuler fibres in the electromagnetic case. The quantum space-time form factor used in the massive case gives rise in the present case to quantum gauge frames whose elements are generalized coherent states corresponding to pseudounitary spin-one representations of direct products of the Poincare group with the U(1), SU(N) or other internal gauge groups. Quantum connections are introduced on bundles of second-quantized frames, and the corresponding parallel transport is expressed in terms of path integrals for quantum frame propagators. In the Yang-Mills case, these path integral make use of Faddeev-Popov quantum frames. It is shown, however, that in the present framework the ghost fields that give rise to these frames possess a geometric interpretation related to the presence of a super-gauge group that, in addition to the external Poincare and Yang-Mills gauge degrees of freedom, involves also the internal ones related to choices of gauge bases within the quantum fibres

  8. MR imaging findings of high-voltage electrical burns in the upper extremities: correlation with angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyung Kyu; Kang, Ik Won; Hwang, Dae Hyun; Min, Seon Jung; Han, You Mi (Dept. of Radiology, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of)); Suh, Kyung Jin (Dept. of Radiology, Dongguk Univ. College of Medicine, Gyeongju Hospital, Gyeongju (Korea, Republic of)), email: kyungjin.suh@gmail.com; Choi, Min Ho (Dept. of Internal Medicine, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of))

    2011-02-15

    Background: A high-voltage electrical burn is often associated with deep muscle injuries. Hidden, undetected deep muscle injuries have a tendency for progressive tissue necrosis, and this can lead to major amputations or sepsis. MRI has excellent soft tissue contrast and it may aid in differentiating the areas of viable deep muscle from the areas of non-viable deep muscle. Purpose: To describe the MR imaging findings of a high-voltage electrical burn in the upper extremity with emphasis on the usefulness of the gadolinium-enhanced MRI and to compare the MR imaging findings with angiography. Material and Methods: We retrospectively reviewed the imaging studies of six patients with high-voltage electrical burns who underwent both MRI and angiography at the burn center of our hospital from January 2005 to December 2009. The imaging features were evaluated for the involved locations, the MR signal intensity of the affected muscles, the MR enhancement pattern, the involved arteries and the angiographic findings (classified as normal, sluggish flow, stenosis or occlusion) of the angiography of the upper extremity. We assessed the relationship between the MR imaging findings and the angiographic findings. Results: The signal intensities of affected muscles were isointense or of slightly high signal intensity as compared with the adjacent unaffected skeletal muscle on the T1-weighted MR images. Affected muscles showed heterogenous high signal intensity relative to the adjacent unaffected skeletal muscle on the T2- weighted images. The gadolinium-enhanced T1-weighted images showed diffuse inhomogeneous enhancement or peripheral rim enhancement of the affected muscles. The angiographic findings of the arterial injuries showed complete occlusion in three patients, severe stenosis in two patients and sluggish flow in one patient. Of these, the five patients with complete occlusion or severe stenosis on angiography showed non-perfused and non-viable areas of edematous muscle on

  9. Quantum field theory in spaces with closed time-like curves

    International Nuclear Information System (INIS)

    Boulware, D.G.

    1992-01-01

    Gott spacetime has closed timelike curves, but no locally anomalous stress-energy. A complete orthonormal set of eigenfunctions of the wave operator is found in the special case of a spacetime in which the total deficit angle is 27π. A scalar quantum field theory is constructed using these eigenfunctions. The resultant interacting quantum field theory is not unitary because the field operators can create real, on-shell, particles in the acausal region. These particles propagate for finite proper time accumulating an arbitrary phase before being annihilated at the same spacetime point as that at which they were created. As a result, the effective potential within the acausal region is complex, and probability is not conserved. The stress tensor of the scalar field is evaluated in the neighborhood of the Cauchy horizon; in the case of a sufficiently small Compton wavelength of the field, the stress tensor is regular and cannot prevent the formation of the Cauchy horizon

  10. Simulating variable-density flows with time-consistent integration of Navier-Stokes equations

    Science.gov (United States)

    Lu, Xiaoyi; Pantano, Carlos

    2017-11-01

    In this talk, we present several features of a high-order semi-implicit variable-density low-Mach Navier-Stokes solver. A new formulation to solve pressure Poisson-like equation of variable-density flows is highlighted. With this formulation of the numerical method, we are able to solve all variables with a uniform order of accuracy in time (consistent with the time integrator being used). The solver is primarily designed to perform direct numerical simulations for turbulent premixed flames. Therefore, we also address other important elements, such as energy-stable boundary conditions, synthetic turbulence generation, and flame anchoring method. Numerical examples include classical non-reacting constant/variable-density flows, as well as turbulent premixed flames.

  11. Hot-electron-assisted femtochemistry at surfaces: A time-dependent density functional theory approach

    DEFF Research Database (Denmark)

    Gavnholt, Jeppe; Rubio, Angel; Olsen, Thomas

    2009-01-01

    Using time-evolution time-dependent density functional theory (TDDFT) within the adiabatic local-density approximation, we study the interactions between single electrons and molecular resonances at surfaces. Our system is a nitrogen molecule adsorbed on a ruthenium surface. The surface is modele...... resonance and the lowering of the resonance energy due to an image charge effect. Finally we apply the TDDFT procedure to only consider the decay of molecular excitations and find that it agrees quite well with the width of the projected density of Kohn-Sham states....

  12. Fast virtual functional assessment of intermediate coronary lesions using routine angiographic data and blood flow simulation in humans: comparison with pressure wire - fractional flow reserve.

    Science.gov (United States)

    Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Lakkas, Lampros S; Nakatani, Shimpei; Bourantas, Christos V; Ligthart, Jurgen; Onuma, Yoshinobu; Echavarria-Pinto, Mauro; Tsirka, Georgia; Kotsia, Anna; Nikas, Dimitrios N; Mogabgab, Owen; van Geuns, Robert-Jan; Naka, Katerina K; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Zijlstra, Felix; Michalis, Lampros K; Serruys, Patrick W

    2014-09-01

    To develop a simplified approach of virtual functional assessment of coronary stenosis from routine angiographic data and test it against fractional flow reserve using a pressure wire (wire-FFR). Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by wire-FFR (reference standard: ≤0.80). The 3D-QCA models were processed with computational fluid dynamics (CFD) to calculate the lesion-specific pressure gradient (ΔP) and construct the ΔP-flow curve, from which the virtual functional assessment index (vFAI) was derived. The discriminatory power of vFAI for ischaemia- producing lesions was high (area under the receiver operator characteristic curve [AUC]: 92% [95% CI: 86-96%]). Diagnostic accuracy, sensitivity and specificity for the optimal vFAI cut-point (≤0.82) were 88%, 90% and 86%, respectively. Virtual-FAI demonstrated superior discrimination against 3D-QCA-derived % area stenosis (AUC: 78% [95% CI: 70- 84%]; p<0.0001 compared to vFAI). There was a close correlation (r=0.78, p<0.0001) and agreement of vFAI compared to wire-FFR (mean difference: -0.0039±0.085, p=0.59). We developed a fast and simple CFD-powered virtual haemodynamic assessment model using only routine angiography and without requiring any invasive physiology measurements/hyperaemia induction. Virtual-FAI showed a high diagnostic performance and incremental value to QCA for predicting wire-FFR; this "less invasive" approach could have important implications for patient management and cost.

  13. Lagrangian Curves on Spectral Curves of Monopoles

    International Nuclear Information System (INIS)

    Guilfoyle, Brendan; Khalid, Madeeha; Ramon Mari, Jose J.

    2010-01-01

    We study Lagrangian points on smooth holomorphic curves in TP 1 equipped with a natural neutral Kaehler structure, and prove that they must form real curves. By virtue of the identification of TP 1 with the space LE 3 of oriented affine lines in Euclidean 3-space, these Lagrangian curves give rise to ruled surfaces in E 3 , which we prove have zero Gauss curvature. Each ruled surface is shown to be the tangent lines to a curve in E 3 , called the edge of regression of the ruled surface. We give an alternative characterization of these curves as the points in E 3 where the number of oriented lines in the complex curve Σ that pass through the point is less than the degree of Σ. We then apply these results to the spectral curves of certain monopoles and construct the ruled surfaces and edges of regression generated by the Lagrangian curves.

  14. Vacuum polarization in curved spacetime

    International Nuclear Information System (INIS)

    Guy, R.W.

    1979-01-01

    A necessary step in the process of understanding the quantum theory of gravity is the calculation of the stress-energy tensor of quantized fields in curved space-times. The determination of the stress tensor, a formally divergent object, is made possible in this dissertation by utilizing the zeta-function method of regularization and renormalization. By employing this scheme's representation of the renormalized effective action functional, an expression of the stress tensor for a massless, conformally invariant scalar field, first given by DeWitt, is derived. The form of the renormalized stress tensor is first tested in various examples of flat space-times. It is shown to vanish in Minkowski space and to yield the accepted value of the energy density in the Casimir effect. Next, the stress tensor is calculated in two space-times of constant curvature, the Einstein universe and the deSitter universe, and the results are shown to agree with those given by an expression of the stress tensor that is valid in conformally flat space-times. This work culminates in the determination of the stress tensor on the horizon of a Schwarzschild black hole. This is accomplished by approximating the radial part of the eigen-functions and the metric in the vicinity of the horizon. The stress tensor at this level approximation is found to be pure trace. The approximated forms of the Schwarzschild metric describes a conformally flat space-time that possesses horizons

  15. Role of disc area and trabecular bone density on lumbar spinal column fracture risk curves under vertical impact.

    Science.gov (United States)

    Yoganandan, Narayan; Moore, Jason; Pintar, Frank A; Banerjee, Anjishnu; DeVogel, Nicholas; Zhang, JiangYue

    2018-04-27

    While studies have been conducted using human cadaver lumbar spines to understand injury biomechanics in terms of stability/energy to fracture, and physiological responses under pure-moment/follower loads, data are sparse for inferior-to-superior impacts. Injuries occur under this mode from underbody blasts. determine role of age, disc area, and trabecular bone density on tolerances/risk curves under vertical loading from a controlled group of specimens. T12-S1 columns were obtained, pretest X-rays and CTs taken, load cells attached to both ends, impacts applied at S1-end using custom vertical accelerator device, and posttest X-ray, CT, and dissections done. BMD of L2-L4 vertebrae were obtained from QCT. Survival analysis-based Human Injury Probability Curves (HIPCs) were derived using proximal and distal forces. Age, area, and BMD were covariates. Forces were considered uncensored, representing the load carrying capacity. The Akaike Information Criterion was used to determine optimal distributions. The mean forces, ±95% confidence intervals, and Normalized Confidence Interval Size (NCIS) were computed. The Lognormal distribution was the optimal function for both forces. Age, area, and BMD were not significant (p > 0.05) covariates for distal forces, while only BMD was significant for proximal forces. The NCIS was the lowest for force-BMD covariate HIPC. The HIPCs for both genders at 35 and 45 years were based on population BMDs. These HIPCs serve as human tolerance criteria for automotive, military, and other applications. In this controlled group of samples, BMD is a better predictor-covariate that characterizes lumbar column injury under inferior-to-superior impacts. Published by Elsevier Ltd.

  16. Time-dependent quantum fluid density functional theory of hydrogen ...

    Indian Academy of Sciences (India)

    A time-dependent generalized non-linear Schrödinger equation (GNLSE) of motion was earlier derived in our laboratory by combining density functional theory and quantum fluid dynamics in threedimensional space. In continuation of the work reported previously, the GNLSE is applied to provide additional knowledge on ...

  17. Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis.

    Science.gov (United States)

    Shen, Mingkui; Jiang, Honghui; Luo, Ming; Wang, Wengang; Li, Ning; Wang, Lulu; Xia, Lei

    2017-08-02

    The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS. We retrospectively reviewed 62 consecutive Lenke 1 AIS patients who underwent posterior spinal arthrodesis using all-pedicle screw instrumentation with a minimum follow-up of 24 months. The implant density was defined as the number of screws per spinal level fused. Patients were then divided into two groups according to the average implant density for the entire study. The LD group (n = 28) had fewer than 1.61 screws per level, while the HD group (n = 34) had more than 1.61 screws per level. The radiographs were analysed preoperatively, postoperatively and at final follow-up. The perioperative and SRS-22 outcomes were also assessed. Independent sample t tests were used between the two groups. Comparisons between the two groups showed no significant differences in the correction of the main thoracic curve and thoracic kyphosis, blood transfusion, hospital stay, and SRS-22 scores. Compared with the HD group, there was a decreased operating time (278.4 vs. 331.0 min, p = 0.004) and decreased blood loss (823.6 vs. 1010.9 ml, p = 0.048), pedicle screws needed (15.1 vs. 19.6, p density and high density pedicle screw instrumentation achieved satisfactory deformity correction in Lenke 1 AIS patients. However, the operating time and blood loss were reduced, and the implant costs were decreased with the use of low screw density constructs.

  18. Angiographic characteristics of premature coronary artery disease in pakistan population; a prospective cross-sectional study

    International Nuclear Information System (INIS)

    Mustafa, B.; Rahman, H.U.

    2015-01-01

    Objective: To study the angiographic characteristics of premature coronary artery disease in our population. Methodology: From April 2014 to March 2015, coronary angiograms of 102 patients less than 40 years of age with a definitive diagnosis of ischemic heart disease were studied. Traditional risk factors of atherosclerosis were documented. Mode of presentation and symptoms were recorded along with angiographic findings of coronary artery disease severity, degree of coronary involvement, culprit vessel, lesion morphology, coronary dominance, coronary ectasia and left ventricular systolic function. Results: Mean age was 36.4 ± 4.1 years and 91% were male. Overall, left ventricular systolic function were fairly preserved (82%). 52% patients had single vessel CAD, 25% had double vessel while 19% had triple vessel coronary artery disease. Four patients had no luminal stenosis on coronary angiogram. LAD was the culprit vessel in 58.8%, RCA in 24.5% and left circumflex artery in 16.7% cases. More than 82% culprit lesions were severe or critical. 58% lesions were morphologically complex B2/C type while only 42% lesions were type A/B1. Coronary ectasia was seen in nearly 25% cases and all had ACS presentation. Right dominance was more common than left (57.8% vs 37.3%) while only 4.9% cases had dual posterior septal supply. Conclusion: Premature CAD in our population is acutely symptomatic, severe, complex (B2/C), single vessel disease. (author)

  19. Wavelet-based linear-response time-dependent density-functional theory

    Science.gov (United States)

    Natarajan, Bhaarathi; Genovese, Luigi; Casida, Mark E.; Deutsch, Thierry; Burchak, Olga N.; Philouze, Christian; Balakirev, Maxim Y.

    2012-06-01

    Linear-response time-dependent (TD) density-functional theory (DFT) has been implemented in the pseudopotential wavelet-based electronic structure program BIGDFT and results are compared against those obtained with the all-electron Gaussian-type orbital program DEMON2K for the calculation of electronic absorption spectra of N2 using the TD local density approximation (LDA). The two programs give comparable excitation energies and absorption spectra once suitably extensive basis sets are used. Convergence of LDA density orbitals and orbital energies to the basis-set limit is significantly faster for BIGDFT than for DEMON2K. However the number of virtual orbitals used in TD-DFT calculations is a parameter in BIGDFT, while all virtual orbitals are included in TD-DFT calculations in DEMON2K. As a reality check, we report the X-ray crystal structure and the measured and calculated absorption spectrum (excitation energies and oscillator strengths) of the small organic molecule N-cyclohexyl-2-(4-methoxyphenyl)imidazo[1, 2-a]pyridin-3-amine.

  20. Computational tools for the construction of calibration curves for use in dose calculations in radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Oliveira, Alex C.H.; Vieira, Jose W.; Escola Politecnica de Pernambuco , Recife, PE

    2011-01-01

    The realization of tissue inhomogeneity corrections in image-based treatment planning improves the accuracy of radiation dose calculations for patients undergoing external-beam radiotherapy. Before the tissue inhomogeneity correction can be applied, the relationship between the computed tomography (CT) numbers and density must be established. This relationship is typically established by a calibration curve empirically obtained from CT images of a phantom that has several inserts of tissue-equivalent materials, covering a wide range of densities. This calibration curve is scanner-dependent and allows the conversion of CT numbers in densities for use in dose calculations. This paper describes the implementation of computational tools necessary to construct calibration curves. These tools are used for reading and displaying of CT images in DICOM format, determination of the mean CT numbers (and their standard deviations) of each tissue-equivalent material and construction of calibration curves by fits with bilinear equations. All these tools have been implemented in the Microsoft Visual Studio 2010 in C≠ programming language. (author)

  1. Comparative functional scintigraphic and angiographic examination in pancreas diseases

    International Nuclear Information System (INIS)

    Mendizov, A.; Brilski, V.; Bozhiyanov, A.; Romanova, A.; Mardzhanov, I.; Glavincheva, I.; Meditsinska Akademiya, Sofia

    1979-01-01

    Pancreas scintigraphy with 75 seleno-methionine, pancreocimine-secretine test and selective abdominal angiography was carried out in patients with chronic pancreatitis, pancreas carcinoma and subjects without any pancreas diseases. Scintigraphic changes in pancreas was found in 95,6 per cent of the patients with chronic pancreatitis (136 patients), in 92 per cent of them with pancreas carcinoma (25 patients) and in 53,4 per cent from the subjects without pancreas diseases (30 examined). Pathological changes in pancreatic secretion was found in 93,4 per cent of the patients with chronic pancreatitis (105 patients), in 93,8 per cent of the subjects with pancreas carcinoma (32 patients) and only in 3,9 per cent from the examined without pancreatic diseases. The angiographic examination is informative mainly in case of tumours and cysts of the pancreas. The diagnostic potentialities of the separate methods for pancreas examination were critically assessed. The basic diagnostic problems in pancreas diseases are solved to a great extent with the combined examination with scintigraphy pancreocimine test and angiography (76 patients). (author)

  2. Detection of Time Lags between Quasar Continuum Emission Bands Based On Pan-STARRS Light Curves

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yan-Fei [Kavli Institute for Theoretical Physics, University of California, Santa Barbara, CA 93106 (United States); Green, Paul J.; Pancoast, Anna; MacLeod, Chelsea L. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Greene, Jenny E. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Morganson, Eric; Shen, Yue [Department of Astronomy, University of Illinois at Urbana-Champaign, Urbana, IL 61801 (United States); Anderson, Scott F.; Ruan, John J. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Brandt, W. N.; Grier, C. J. [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States); Rix, H.-W. [Max Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Protopapas, Pavlos [Institute for Applied Computational Science, John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138 (United States); Scott, Caroline [Astrophysics, Imperial College London, Blackett Laboratory, London SW7 2AZ (United Kingdom); Burgett, W. S.; Hodapp, K. W.; Huber, M. E.; Kaiser, N.; Kudritzki, R. P.; Magnier, E. A. [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu HI 96822 (United States); and others

    2017-02-20

    We study the time lags between the continuum emission of quasars at different wavelengths, based on more than four years of multi-band ( g , r , i , z ) light curves in the Pan-STARRS Medium Deep Fields. As photons from different bands emerge from different radial ranges in the accretion disk, the lags constrain the sizes of the accretion disks. We select 240 quasars with redshifts of z ≈ 1 or z ≈ 0.3 that are relatively emission-line free. The light curves are sampled from day to month timescales, which makes it possible to detect lags on the scale of the light crossing time of the accretion disks. With the code JAVELIN , we detect typical lags of several days in the rest frame between the g band and the riz bands. The detected lags are ∼2–3 times larger than the light crossing time estimated from the standard thin disk model, consistent with the recently measured lag in NGC 5548 and microlensing measurements of quasars. The lags in our sample are found to increase with increasing luminosity. Furthermore, the increase in lags going from g − r to g − i and then to g − z is slower than predicted in the thin disk model, particularly for high-luminosity quasars. The radial temperature profile in the disk must be different from what is assumed. We also find evidence that the lags decrease with increasing line ratios between ultraviolet Fe ii lines and Mg ii, which may point to changes in the accretion disk structure at higher metallicity.

  3. Flux-gradient relationships and soil-water diffusivity from curves of water content versus time

    Energy Technology Data Exchange (ETDEWEB)

    Nofziger, D.L.; Ahuja, L.R.; Swartzendruber, D.

    Direct analysis of a family of curves of soil-water content vs. time at different fixed positions enables assessment of the flux-gradient relationship prior to the calculations of soil-water diffusivity. The method is evaluated on both smooth and random-error data generated from the solution of the horizontal soil-water intake problem with a known diffusivity function. Interpolation, differentiation, and intergration are carried out by least-squares curve fitting based on the 2 recently developed techniques of parabolic splines and sliding parabolas, with all computations performed by computer. Results are excellent for both smooth and random-error input data, whether in terms of recovering the original known diffusivity function, assessing the nature of the flux-gradient relationship, or in making the numerous checks and validations at various intermediate stages of computation. The method applies for any horizontal soil-wetting process independently of the specific boundary conditions, including water entry through a nonzero inlet resistance. It should be adaptable to horizontal dewatering, and extendable to vertical flow. (11 refs.)

  4. CT Angiographic Demonstration of a Mesenteric Vessel 'Whirlpool' in Intestinal Malrotation and Midgut Volvulus: a Case Report

    International Nuclear Information System (INIS)

    Bozlar, Ugur; Ugurel, Mehmet Sahin; Ustunsoz, Bahri; Coskun, Unsal

    2008-01-01

    Although the color Doppler ultrasonography diagnosis of intestinal malrotation with midgut volvulus, based on the typical 'whirlpool' appearance of the mesenteric vascular structures is well-defined in the peer-reviewed literature, the combination of both the angiographic illustration of these findings and the contemporary state-of-the-art imaging techniques is lacking. We report the digital subtraction angiography and multidetector computed tomography angiography findings of a 37-year-old male with intestinal malrotation

  5. A simple method for one-loop renormalization in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Markkanen, Tommi [Helsinki Institute of Physics and Department of Physics, P.O. Box 64, FI-00014, University of Helsinki (Finland); Tranberg, Anders, E-mail: tommi.markkanen@helsinki.fi, E-mail: anders.tranberg@uis.no [Niels Bohr International Academy and Discovery Center, Niels Bohr Institute, Blegdamsvej 17, 2100 Copenhagen (Denmark)

    2013-08-01

    We present a simple method for deriving the renormalization counterterms from the components of the energy-momentum tensor in curved space-time. This method allows control over the finite parts of the counterterms and provides explicit expressions for each term separately. As an example, the method is used for the self-interacting scalar field in a Friedmann-Robertson-Walker metric in the adiabatic approximation, where we calculate the renormalized equation of motion for the field and the renormalized components of the energy-momentum tensor to fourth adiabatic order while including interactions to one-loop order. Within this formalism the trace anomaly, including contributions from interactions, is shown to have a simple derivation. We compare our results to those obtained by two standard methods, finding agreement with the Schwinger-DeWitt expansion but disagreement with adiabatic subtractions for interacting theories.

  6. Observational evidence of dust evolution in galactic extinction curves

    Energy Technology Data Exchange (ETDEWEB)

    Cecchi-Pestellini, Cesare [INAF-Osservatorio Astronomico di Palermo, P.zza Parlamento 1, I-90134 Palermo (Italy); Casu, Silvia; Mulas, Giacomo [INAF-Osservatorio Astronomico di Cagliari, Via della Scienza, I-09047 Selargius (Italy); Zonca, Alberto, E-mail: cecchi-pestellini@astropa.unipa.it, E-mail: silvia@oa-cagliari.inaf.it, E-mail: gmulas@oa-cagliari.inaf.it, E-mail: azonca@oa-cagliari.inaf.it [Dipartimento di Fisica, Università di Cagliari, Strada Prov.le Monserrato-Sestu Km 0.700, I-09042 Monserrato (Italy)

    2014-04-10

    Although structural and optical properties of hydrogenated amorphous carbons are known to respond to varying physical conditions, most conventional extinction models are basically curve fits with modest predictive power. We compare an evolutionary model of the physical properties of carbonaceous grain mantles with their determination by homogeneously fitting observationally derived Galactic extinction curves with the same physically well-defined dust model. We find that a large sample of observed Galactic extinction curves are compatible with the evolutionary scenario underlying such a model, requiring physical conditions fully consistent with standard density, temperature, radiation field intensity, and average age of diffuse interstellar clouds. Hence, through the study of interstellar extinction we may, in principle, understand the evolutionary history of the diffuse interstellar clouds.

  7. Critique of the foundations of time-dependent density-functional theory

    International Nuclear Information System (INIS)

    Schirmer, J.; Dreuw, A.

    2007-01-01

    The general expectation that, in principle, the time-dependent density-functional theory (TDDFT) is an exact formulation of the time evolution of an interacting N-electron system is critically reexamined. It is demonstrated that the previous TDDFT foundation, resting on four theorems by Runge and Gross (RG) [Phys. Rev. Lett. 52, 997 (1984)], is invalid because undefined phase factors corrupt the RG action integral functionals. Our finding confirms much of a previous analysis by van Leeuwen [Int. J. Mod. Phys. B 15, 1969 (2001)]. To analyze the RG theorems and other aspects of TDDFT, an utmost simplification of the Kohn-Sham (KS) concept has been introduced, in which the ground-state density is obtained from a single KS equation for one spatial (spinless) orbital. The time-dependent (TD) form of this radical Kohn-Sham (rKS) scheme, which has the same validity status as the ordinary KS version, has proved to be a valuable tool for analysis. The rKS concept is used to clarify also the alternative nonvariational formulation of TD KS theory. We argue that it is just a formal theory, allowing one to reproduce but not predict the time development of the exact density of the interacting N-electron system. Besides the issue of the formal exactness of TDDFT, it is shown that both the static and time-dependent KS linear response equations neglect the particle-particle (p-p) and hole-hole (h-h) matrix elements of the perturbing operator. For a local (multiplicative) operator this does not lead to a loss of information due to a remarkable general property of local operators. Accordingly, no logical inconsistency arises with respect to DFT, because DFT requires any external potential to be local. For a general nonlocal operator the error resulting from the neglected matrix elements is of second order in the electronic repulsion

  8. Characterization of type, position and dimension of flaws by transit time locus curves of ultrasonic inspections - ALOK. Pt. 2

    International Nuclear Information System (INIS)

    Grohs, B.; Barbian, O.A.; Kappes, W.; Paul, H.

    1981-01-01

    With automatic ultrasonic testing, flaws can be detected and described and thus characterized according to their type, position and dimensions. During scanning of a test object, the flaws are registered by many different pathways and many different acoustic irradiation directions. The transit time locus curve represents the distance between the relfecting points of a flaw and the source in dependence of the probe position; hence, information on flaw position and dimensions can be derived from this curve. If the sound velocity is known, the transit path can then be calculated from the transit time. This requires, above all, a constant sound velocity along the whole transit path. Various methods are presented for reconstructing the flaw border in the plane of incidence. (orig./RW) [de

  9. Time-dependent density-functional theory in the projector augmented-wave method

    DEFF Research Database (Denmark)

    Walter, Michael; Häkkinen, Hannu; Lehtovaara, Lauri

    2008-01-01

    We present the implementation of the time-dependent density-functional theory both in linear-response and in time-propagation formalisms using the projector augmented-wave method in real-space grids. The two technically very different methods are compared in the linear-response regime where we...

  10. Learning curves in health professions education.

    Science.gov (United States)

    Pusic, Martin V; Boutis, Kathy; Hatala, Rose; Cook, David A

    2015-08-01

    Learning curves, which graphically show the relationship between learning effort and achievement, are common in published education research but are not often used in day-to-day educational activities. The purpose of this article is to describe the generation and analysis of learning curves and their applicability to health professions education. The authors argue that the time is right for a closer look at using learning curves-given their desirable properties-to inform both self-directed instruction by individuals and education management by instructors.A typical learning curve is made up of a measure of learning (y-axis), a measure of effort (x-axis), and a mathematical linking function. At the individual level, learning curves make manifest a single person's progress towards competence including his/her rate of learning, the inflection point where learning becomes more effortful, and the remaining distance to mastery attainment. At the group level, overlaid learning curves show the full variation of a group of learners' paths through a given learning domain. Specifically, they make overt the difference between time-based and competency-based approaches to instruction. Additionally, instructors can use learning curve information to more accurately target educational resources to those who most require them.The learning curve approach requires a fine-grained collection of data that will not be possible in all educational settings; however, the increased use of an assessment paradigm that explicitly includes effort and its link to individual achievement could result in increased learner engagement and more effective instructional design.

  11. The effects of variability on the number-flux-density relationship for radio sources

    International Nuclear Information System (INIS)

    Schuch, N.J.

    1981-01-01

    It has been known for some time that the number-flux-density relationship for radio sources requires a population of sources whose properties evolve with cosmological epoch, at least in models where the redshifts are all taken to be cosmological. In particular, the surveys made at metre wavelengths show, for bright sources, a slope of the log N -log S curve which is steeper than the value -1.5 expected in a static, non-evolving Euclidean universe. Here, N is the number of radio sources brighter than flux density S. Expansion without evolution in conventional geometrical models predicts slopes flatter than -1.5. If the radio survey is carried out at higher frequencies (typically 2.7 or 5 GHz - 11 or 6 cm wavelength), the slope of the log N -log S curve is steeper than -1.5 but not so steep as the slopes found for the low-frequency surveys. Many of the sources found in high-frequency surveys have radio spectra with relatively higher flux-densities in the centimetre range; these sources are frequently variable at high frequencies, with time-scales from a month or two upwards. Some possible effects of the variations on the observed counts of radio sources are considered. (author)

  12. Spatially heterogeneous dynamics investigated via a time-dependent four-point density correlation function

    DEFF Research Database (Denmark)

    Lacevic, N.; Starr, F. W.; Schrøder, Thomas

    2003-01-01

    correlation function g4(r,t) and corresponding "structure factor" S4(q,t) which measure the spatial correlations between the local liquid density at two points in space, each at two different times, and so are sensitive to dynamical heterogeneity. We study g4(r,t) and S4(q,t) via molecular dynamics......Relaxation in supercooled liquids above their glass transition and below the onset temperature of "slow" dynamics involves the correlated motion of neighboring particles. This correlated motion results in the appearance of spatially heterogeneous dynamics or "dynamical heterogeneity." Traditional...... two-point time-dependent density correlation functions, while providing information about the transient "caging" of particles on cooling, are unable to provide sufficiently detailed information about correlated motion and dynamical heterogeneity. Here, we study a four-point, time-dependent density...

  13. Deep-learnt classification of light curves

    DEFF Research Database (Denmark)

    Mahabal, Ashish; Gieseke, Fabian; Pai, Akshay Sadananda Uppinakudru

    2017-01-01

    is to derive statistical features from the time series and to use machine learning methods, generally supervised, to separate objects into a few of the standard classes. In this work, we transform the time series to two-dimensional light curve representations in order to classify them using modern deep......Astronomy light curves are sparse, gappy, and heteroscedastic. As a result standard time series methods regularly used for financial and similar datasets are of little help and astronomers are usually left to their own instruments and techniques to classify light curves. A common approach...... learning techniques. In particular, we show that convolutional neural networks based classifiers work well for broad characterization and classification. We use labeled datasets of periodic variables from CRTS survey and show how this opens doors for a quick classification of diverse classes with several...

  14. Projection-based curve clustering

    International Nuclear Information System (INIS)

    Auder, Benjamin; Fischer, Aurelie

    2012-01-01

    This paper focuses on unsupervised curve classification in the context of nuclear industry. At the Commissariat a l'Energie Atomique (CEA), Cadarache (France), the thermal-hydraulic computer code CATHARE is used to study the reliability of reactor vessels. The code inputs are physical parameters and the outputs are time evolution curves of a few other physical quantities. As the CATHARE code is quite complex and CPU time-consuming, it has to be approximated by a regression model. This regression process involves a clustering step. In the present paper, the CATHARE output curves are clustered using a k-means scheme, with a projection onto a lower dimensional space. We study the properties of the empirically optimal cluster centres found by the clustering method based on projections, compared with the 'true' ones. The choice of the projection basis is discussed, and an algorithm is implemented to select the best projection basis among a library of orthonormal bases. The approach is illustrated on a simulated example and then applied to the industrial problem. (authors)

  15. Deep-learnt classification of light curves

    DEFF Research Database (Denmark)

    Mahabal, Ashish; Gieseke, Fabian; Pai, Akshay Sadananda Uppinakudru

    2017-01-01

    Astronomy light curves are sparse, gappy, and heteroscedastic. As a result standard time series methods regularly used for financial and similar datasets are of little help and astronomers are usually left to their own instruments and techniques to classify light curves. A common approach is to d...

  16. Microwave measurements of the time evolution of electron density in the T-11M tokamak

    International Nuclear Information System (INIS)

    Petrov, V.G.; Petrov, A.A.; Malyshev, A.Yu.; Markov, V.K.; Babarykin, A.V.

    2004-01-01

    Unambiguous diagnostics intended for measuring the time behavior of the electron density and monitoring the line-averaged plasma density in the T-11M tokamak are described. The time behavior of the plasma density in the T-11M tokamak is measured by a multichannel phase-jump-free microwave polarization interferometer based on the Cotton-Mouton effect. After increasing the number of simultaneously operating interferometer channels and enhancing the sensitivity of measurements, it became possible to measure the time evolution of the plasma density profile in the T-11M tokamak. The first results from such measurements in various operating regimes of the T-11M tokamak are presented. The measurement and data processing techniques are described, the measurement errors are analyzed, and the results obtained are discussed. We propose using a pulsed time-of-flight refractometer to monitor the average plasma density in the T-11M tokamak. The refractometer emits nanosecond microwave probing pulses with a carrier frequency that is higher than the plasma frequency and, thus, operates in the transmission mode. A version of the instrument has been developed with a carrier frequency of 140 GHz, which allows one to measure the average density in regimes with a nominal T-11M plasma density of (3-5) x 10 13 cm -3 . Results are presented from the first measurements of the average density in the T-11M tokamak with the help of a pulsed time-of-flight refractometer by probing the plasma in the equatorial plane in a regime with the reflection of the probing radiation from the inner wall of the vacuum chamber

  17. Extending the range of real time density matrix renormalization group simulations

    Science.gov (United States)

    Kennes, D. M.; Karrasch, C.

    2016-03-01

    We discuss a few simple modifications to time-dependent density matrix renormalization group (DMRG) algorithms which allow to access larger time scales. We specifically aim at beginners and present practical aspects of how to implement these modifications within any standard matrix product state (MPS) based formulation of the method. Most importantly, we show how to 'combine' the Schrödinger and Heisenberg time evolutions of arbitrary pure states | ψ 〉 and operators A in the evaluation of 〈A〉ψ(t) = 〈 ψ | A(t) | ψ 〉 . This includes quantum quenches. The generalization to (non-)thermal mixed state dynamics 〈A〉ρ(t) =Tr [ ρA(t) ] induced by an initial density matrix ρ is straightforward. In the context of linear response (ground state or finite temperature T > 0) correlation functions, one can extend the simulation time by a factor of two by 'exploiting time translation invariance', which is efficiently implementable within MPS DMRG. We present a simple analytic argument for why a recently-introduced disentangler succeeds in reducing the effort of time-dependent simulations at T > 0. Finally, we advocate the python programming language as an elegant option for beginners to set up a DMRG code.

  18. Multiplex real-time PCR assay for the detection of extended-spectrum β-lactamase and carbapenemase genes using melting curve analysis.

    Science.gov (United States)

    Singh, Prashant; Pfeifer, Yvonne; Mustapha, Azlin

    2016-05-01

    Real-time PCR melt curve assays for the detection of β-lactamase, extended-spectrum β-lactamase and carbapenemase genes in Gram-negative bacteria were developed. Two multiplex real-time PCR melt curve assays were developed for the detection of ten common β-lactamase genes: blaKPC-like, blaOXA-48-like, blaNDM-like, blaVIM-like, blaIMP-like, blaCTX-M-1+2-group, blaCMY-like, blaACC-like, blaSHV-like and blaTEM-like. The assays were evaluated using 25 bacterial strains and 31 DNA samples (total n=56) comprising different Enterobacteriaceae genera and Pseudomonas spp. These strains were previously characterized at five research institutes. Each resistance gene targeted in this study generated a non-overlapping and distinct melt curve peak. The assay worked effectively and detected the presence of additional resistance genes in 23 samples. The assays developed in this study offer a simple, low cost method for the detection of prevalent β-lactamase, ESBL and carbapenemase genes among Gram-negative pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Simultaneous occurrence of a severe Morel-Lavallée lesion and gluteal muscle necrosis as a sequela of transcatheter angiographic embolization following pelvic fracture: a case report.

    Science.gov (United States)

    Shimizu, Takayoshi; Matsuda, Shuichi; Sakuragi, Atsushi; Tsukie, Tomio; Kawanabe, Keiichi

    2015-03-26

    Morel-Lavallée lesions are posttraumatic hemolymphatic collections caused by disruption of the interfascial planes between the subcutaneous soft tissue and muscle. Severe peripelvic Morel-Lavallée lesions have rarely been reported in the literature. By contrast, a number of cases of gluteal muscle necrosis following transcatheter angiographic embolization for pelvic fracture have been reported. Each entity can result in severe infection and sepsis, and the mortality rate in such cases is quite high. However, to date, no previous reports have described a case in which these life-threatening entities occurred simultaneously. A 32-year-old Asian man simultaneously developed severe peripelvic Morel-Lavallée lesions and gluteal muscle necrosis with sepsis following transcatheter angiographic embolization after an unstable pelvic fracture. Extremely large skin and soft tissue defects, which were untreatable with any commonly used flaps, were generated after repeated debridement. In addition, a deep-bone infection was suspected in his left fractured iliac bone, while motor function was almost completely lost in his left leg, possibly as a sequela of transcatheter angiographic embolization. As a result of his condition, a left hemipelvectomy was unavoidable. A pedicled fillet flap from his sacrificed left limb was used for the treatment of the defects and to provide a durable base for a prosthesis. Our patient survived and returned to his previous job 24 months after the surgery wearing a prosthetic left leg. As illustrated by the present case, severe peripelvic Morel-Lavallée lesions and gluteal muscle necrosis following transcatheter angiographic embolization can occur simultaneously after unstable pelvic fractures. Physicians should recognize that these entities can result in life-threatening sepsis and, therefore, should attempt to detect them as early as possible. When hemipelvectomy is unavoidable, a pedicled upper and lower leg in-continuity fillet flap may

  20. Time-Dependent Density Functional Theory for Open Systems and Its Applications.

    Science.gov (United States)

    Chen, Shuguang; Kwok, YanHo; Chen, GuanHua

    2018-02-20

    Photovoltaic devices, electrochemical cells, catalysis processes, light emitting diodes, scanning tunneling microscopes, molecular electronics, and related devices have one thing in common: open quantum systems where energy and matter are not conserved. Traditionally quantum chemistry is confined to isolated and closed systems, while quantum dissipation theory studies open quantum systems. The key quantity in quantum dissipation theory is the reduced system density matrix. As the reduced system density matrix is an O(M! × M!) matrix, where M is the number of the particles of the system of interest, quantum dissipation theory can only be employed to simulate systems of a few particles or degrees of freedom. It is thus important to combine quantum chemistry and quantum dissipation theory so that realistic open quantum systems can be simulated from first-principles. We have developed a first-principles method to simulate the dynamics of open electronic systems, the time-dependent density functional theory for open systems (TDDFT-OS). Instead of the reduced system density matrix, the key quantity is the reduced single-electron density matrix, which is an N × N matrix where N is the number of the atomic bases of the system of interest. As the dimension of the key quantity is drastically reduced, the TDDFT-OS can thus be used to simulate the dynamics of realistic open electronic systems and efficient numerical algorithms have been developed. As an application, we apply the method to study how quantum interference develops in a molecular transistor in time domain. We include electron-phonon interaction in our simulation and show that quantum interference in the given system is robust against nuclear vibration not only in the steady state but also in the transient dynamics. As another application, by combining TDDFT-OS with Ehrenfest dynamics, we study current-induced dissociation of water molecules under scanning tunneling microscopy and follow its time dependent

  1. Relativistic electron-beam transport in curved channels

    International Nuclear Information System (INIS)

    Vittitoe, C.N.; Morel, J.E.; Wright, T.P.

    1982-01-01

    Collisionless single particle trajectories are modeled for a single plasma channel having one section curved in a circular arc. The magnetic field is developed by superposition of straight and curved channel segments. The plasma density gives charge and beam-current neutralization. High transport efficiencies are found for turning a relativistic electron beam 90 0 under reasonable conditions of plasma current, beam energy, arc radius, channel radius, and injection distributions in velocity and in position at the channel entrance. Channel exit distributions in velocity and position are found consistent with those for a straight plasma channel of equivalent length. Such transport problems are important in any charged particle-beam application constrained by large diode-to-target distance or by requirements of maximum power deposition in a confined area

  2. Analysis of the static pressure volume curve of the lung in experimentally induced pulmonary damage by CT-densitometry

    International Nuclear Information System (INIS)

    David, M.; Karmrodt, J.; Herwelling, A.; Bletz, C.; David, S.; Heussel, C.P.; Markstaller, K.

    2005-01-01

    Purpose: To study quantitative changes of lung density distributions when recording in- and expiratory static pressure-volume curves by single slice computed tomography (CT). Materials and Methods: Static in- and expiratory pressure volume curves (0 to 1000 ml, increments of 100 ml) were obtained in random order in 10 pigs after induction of lung damage by saline lavage. Simultaneously, CT acquisitions (slice thickness 1 mm, temporal increment 2 s) were performed in a single slice (3 cm below the carina). In each CT image lung segmentation and planimetry of defined density ranges were achieved. The lung density ranges were defined as: hyperinflated (-1024 to -910 HU), normal aerated (-910 to -600 HU), poorly aerated (-600 to -300 HU), and non aerated (-300 to 200 HU) lung. Fractional areas of defined density ranges in percentage of total lung area were compared to recorded volume increments and airway pressures (atmospheric pressure, lower inflection point (LIP), LIP*0.5, LIP*1.5, peak airway pressure) of in- and expiratory pressure-volume curves. Results: Quantitative analysis of defined density ranges showed no differences between in- and expiratory pressure-volume curves. The amount of poorly aerated lung decreased and normal aerated lung increased constantly when airway pressure and volume were increased during inspiratory pressure-volume curves and vice versa during expiratory pressure-volume loops. Conclusion: Recruitment and derecruitment of lung atelectasis during registration of static in- and expiratory pressure-volume loops occurred constantly, but not in a stepwise manner. CT was shown to be an appropriate method to analyse these recruitment process. (orig.)

  3. Excited-state absorption in tetrapyridyl porphyrins: comparing real-time and quadratic-response time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, David N. [Department of Chemistry; Supercomputing Institute and Chemical Theory Center; University of Minnesota; Minneapolis; USA; Asher, Jason C. [Department of Chemistry; Supercomputing Institute and Chemical Theory Center; University of Minnesota; Minneapolis; USA; Fischer, Sean A. [William R. Wiley Environmental Molecular Sciences Laboratory; Pacific Northwest National Laboratory; P.O. Box 999; Richland; USA; Cramer, Christopher J. [Department of Chemistry; Supercomputing Institute and Chemical Theory Center; University of Minnesota; Minneapolis; USA; Govind, Niranjan [William R. Wiley Environmental Molecular Sciences Laboratory; Pacific Northwest National Laboratory; P.O. Box 999; Richland; USA

    2017-01-01

    Threemeso-substituted tetrapyridyl porphyrins (free base, Ni(ii), and Cu(ii)) were investigated for their optical limiting (OL) capabilities using real-time (RT-), linear-response (LR-), and quadratic-response (QR-) time-dependent density functional theory (TDDFT) methods.

  4. NOISY DISPERSION CURVE PICKING (NDCP): a Matlab friendly suite package for fully control dispersion curve picking

    Science.gov (United States)

    Granados, I.; Calo, M.; Ramos, V.

    2017-12-01

    We developed a Matlab suite package (NDCP, Noisy Dispersion Curve Picking) that allows a full control over parameters to identify correctly group velocity dispersion curves in two types of datasets: correlograms between two stations or surface wave records from earthquakes. Using the frequency-time analysis (FTAN), the procedure to obtain the dispersion curves from records with a high noise level becomes difficult, and sometimes, the picked curve result in a misinterpreted character. For correlogram functions, obtained with cross-correlation of noise records or earthquake's coda, a non-homogeneous noise sources distribution yield to a non-symmetric Green's function (GF); to retrieve the complete information contained in there, NDCP allows to pick the dispersion curve in the time domain both in the causal and non-causal part of the GF. Then the picked dispersion curve is displayed on the FTAN diagram to in order to check if it matches with the maximum of the signal energy avoiding confusion with overtones or spike of noise. To illustrate how NDCP performs, we show exemple using: i) local correlograms functions obtained from sensors deployed into a volcanic caldera (Los Humeros, in Puebla, Mexico), ii) regional correlograms functions between two stations of the National Seismological Service (SSN, Servicio Sismológico Nacional in Spanish), and iii) surface wave seismic record for an earthquake located in the Pacific Ocean coast of Mexico and recorded by the SSN. This work is supported by the GEMEX project (Geothermal Europe-Mexico consortium).

  5. Machine Learning Techniques for Stellar Light Curve Classification

    Science.gov (United States)

    Hinners, Trisha A.; Tat, Kevin; Thorp, Rachel

    2018-07-01

    We apply machine learning techniques in an attempt to predict and classify stellar properties from noisy and sparse time-series data. We preprocessed over 94 GB of Kepler light curves from the Mikulski Archive for Space Telescopes (MAST) to classify according to 10 distinct physical properties using both representation learning and feature engineering approaches. Studies using machine learning in the field have been primarily done on simulated data, making our study one of the first to use real light-curve data for machine learning approaches. We tuned our data using previous work with simulated data as a template and achieved mixed results between the two approaches. Representation learning using a long short-term memory recurrent neural network produced no successful predictions, but our work with feature engineering was successful for both classification and regression. In particular, we were able to achieve values for stellar density, stellar radius, and effective temperature with low error (∼2%–4%) and good accuracy (∼75%) for classifying the number of transits for a given star. The results show promise for improvement for both approaches upon using larger data sets with a larger minority class. This work has the potential to provide a foundation for future tools and techniques to aid in the analysis of astrophysical data.

  6. Time-dependent density functional theory for many-electron systems interacting with cavity photons.

    Science.gov (United States)

    Tokatly, I V

    2013-06-07

    Time-dependent (current) density functional theory for many-electron systems strongly coupled to quantized electromagnetic modes of a microcavity is proposed. It is shown that the electron-photon wave function is a unique functional of the electronic (current) density and the expectation values of photonic coordinates. The Kohn-Sham system is constructed, which allows us to calculate the above basic variables by solving self-consistent equations for noninteracting particles. We suggest possible approximations for the exchange-correlation potentials and discuss implications of this approach for the theory of open quantum systems. In particular we show that it naturally leads to time-dependent density functional theory for systems coupled to the Caldeira-Leggett bath.

  7. The availability of appropriately fitting personal protective aprons and jackets for angiographic and interventional radiology personnel

    International Nuclear Information System (INIS)

    Cremen, S.A.; McNulty, J.P.

    2014-01-01

    Purpose: This study explored the availability of personal protective equipment, lead or lead-free aprons or jackets, in angiographic and interventional radiology suites in the Republic of Ireland with a focus on the sizes available, appropriateness of fit and purchasing practices. Methods: All centres providing an angiographic or interventional radiology service in the Republic of Ireland were invited to participate with data being collected by means of a postal questionnaire exploring the above issues. Results: The mean number of aprons or jackets available across the centres who responded to the survey was 18.4 with the majority of these, 72%, being medium or large in size. Clinical specialists in three centres identified that there were insufficient aprons or jackets sized extra small or extra large within their departments and only one centre had a purchasing policy in place where individual staff were assigned a personal apron or jacket. Conclusion: Ill-fitting aprons or jackets will reduce the shielding provided to certain body regions by personal protective equipment. The use of over-sized aprons or jackets by staff is of particular concern based on the potential for inadvertent exposure to tissues where cancers may potentially be induced due to poor armhole fit. It is important to carefully consider purchasing practices and range of personal protective equipment sizes available in order to ensure that all staff receive the greatest possible protection from occupational radiation exposure

  8. Intelligent control for modeling of real-time reservoir operation, part II: artificial neural network with operating rule curves

    Science.gov (United States)

    Chang, Ya-Ting; Chang, Li-Chiu; Chang, Fi-John

    2005-04-01

    To bridge the gap between academic research and actual operation, we propose an intelligent control system for reservoir operation. The methodology includes two major processes, the knowledge acquired and implemented, and the inference system. In this study, a genetic algorithm (GA) and a fuzzy rule base (FRB) are used to extract knowledge based on the historical inflow data with a design objective function and on the operating rule curves respectively. The adaptive network-based fuzzy inference system (ANFIS) is then used to implement the knowledge, to create the fuzzy inference system, and then to estimate the optimal reservoir operation. To investigate its applicability and practicability, the Shihmen reservoir, Taiwan, is used as a case study. For the purpose of comparison, a simulation of the currently used M-5 operating rule curve is also performed. The results demonstrate that (1) the GA is an efficient way to search the optimal input-output patterns, (2) the FRB can extract the knowledge from the operating rule curves, and (3) the ANFIS models built on different types of knowledge can produce much better performance than the traditional M-5 curves in real-time reservoir operation. Moreover, we show that the model can be more intelligent for reservoir operation if more information (or knowledge) is involved.

  9. Effects of drive current rise-time and initial load density distribution on Z-pinch characteristics

    Institute of Scientific and Technical Information of China (English)

    Duan Yao-Yong; Guo Yong-Hui; Wang Wen-Sheng; Qiu Ai-Ci

    2005-01-01

    A two-dimensional, three-temperature radiation magneto-hydrodynamics model is applied to the investigation of evolutional trends in x-ray radiation power, energy, peak plasma temperature and density as functions of drive current rise-time and initial load density distribution by using the typical experimental parameters of tungsten wire-array Z-pinch on the Qiangguang-Ⅰ generator. The numerical results show that as the drive current rise-time is shortened, x-ray radiation peak power, energy, peak plasma density and peak ion temperature increase approximately linearly, but among them the x-ray radiation peak power increases more quickly. As the initial plasma density distribution in the radial direction becomes gradually flattened, the peak radiation power and the peak ion-temperature almost exponentially increase, while the radiation energy and the peak plasma density change only a little. The main effect of shortening drive current rise-time is to enhance compression of plasma, and the effect of flattening initial load density distribution in the radial direction is to raise the plasma temperature. Both of the approaches elevate the x-ray peak radiation power.

  10. Progressive Occlusion of Enterprise Stent-Assisted Coiling of Ruptured Wide-Necked Intracranial Aneurysms and Related Factors on Angiographic Follow-Up: A Single-Center Experience with 468 Patients

    Science.gov (United States)

    Liu, Aihua; Li, Youxiang; Jiang, Chuhan; Wu, Zhongxue

    2014-01-01

    This study was designed to assess the effect of the Enterprise stent on progressive occlusion of wide-necked aneurysms and to evaluate the association between dubious factors and progressive occlusion, which is a consecutive, retrospective, single-center study. Data from 468 patients with 495 wide-necked aneurysms, who had undergone Enterprise stent-assisted coiling (SAC) were reviewed, and the clinical outcomes and the angiographic results were analyzed. A 14-month clinical follow-up was achieved in 421 of the 468 patients (90.0%), showing modified Rankin Scale (mRS) 0–1 in 364 (86.4%), mRS 2 in 17 (4.1%), mRS 3 in 17 (4.1%), mRS 4–5 in 9 (2.1%), and mRS 6 in 14 (3.3%) patients. Overall, the morbidity and mortality were 10.2% and 3.3%, respectively. Initial angiographic results showed Raymond scale (RS)1 in 273 (55.2%), RS2 in 194 (39.2%), and RS3 in 28 (5.6%) patients. Eight-month angiographic follow-up was available in 394 of 495 patients (79.6%), and RS1 was seen in 315 (79.9%), RS2 in 65 (16.5%) and RS3 in 14 (3.6%) cases. At the end of the follow-up, 115 of the 165 (69.7%) patients with initial RS2 and RS3 showed progressive occlusion. Statistical analysis showed no significant difference between progressive occlusion and age (p = 0.654), sex (p = 0.016), aneurysm diameter (p = 0.010), neck size (p = 0.124), dome-to neck ratio (DNR) (p = 0.018) and location (p = 0.001) at the time of follow-up. SAC using Enterprise stent is not only feasible for wide-necked aneurysms, but can achieve a high rate of progressive occlusion with good clinical outcomes at medium-term follow-up. Patient age and aneurysm neck size showed no associated with progressive occlusion at follow-up, while sex, aneurysm diameter, DNR and location were significantly associated with progressive occlusion. PMID:24658387

  11. Hyperthermic survival of Chinese hamster ovary cells as a function of cellular population density at the time of plating

    International Nuclear Information System (INIS)

    Highfield, D.P.; Holahan, E.V.; Holahan, P.K.; Dewey, W.C.

    1984-01-01

    The survival of synchronous G 1 or asynchronous Chinese hamster ovary cells in vitro to heat treatment may depend on the cellular population density at the time of heating and/or as the cells are cultured after heating. The addition of lethally irradiated feeder cells may increase survival at 10 -3 by as much as 10- to 100-fold for a variety of conditions when cells are heated either in suspension culture or as monolayers with or without trypsinization. The protective effect associated with feeder cells appears to be associated with close cell-to-cell proximity. However, when cells are heated without trypsinization about 24 hr or later after plating, when adaptation to monolayer has occurred, the protective effect is reduced; i.e., addition of feeder cells enhances survival much less, for example, about 2- to 3-fold at 10 -2 -10 -3 survival. Also, the survival of a cell to heat is independent of whether the neighboring cell in a microcolony is destined to live or die. Finally, if protective effects associated with cell density do occur and are not controlled, serious artifacts can result as the interaction of heat and radiation is studied; for example, survival curves can be moved upward, and thus changed in shape as the number of cells plated is increased with an increase in the hyperthermic treatment or radiation dose following hyperthermia. Therefore, to understand mechanisms and to obtain information relevant to populations of cells in close proximity, such as those in vivo, these cellular population density effects should be considered and understood

  12. Pulsed time-of-flight refractometry measurements of the electron density in the T-11M tokamak

    International Nuclear Information System (INIS)

    Petrov, A.A.; Petrov, V.G.; Malyshev, A.Yu.; Markov, V.K.; Babarykin, A.V.

    2002-01-01

    A new method for measuring the plasma density in magnetic confinement systems - pulsed time-of-flight refractometry - is developed and tested experimentally in the T-11M tokamak. The method is based on the measurements of the time delay of short (with a duration of several nanoseconds) microwave pulses propagating through the plasma. When the probing frequency is much higher than the plasma frequency, the measured delay in the propagation time is proportional to the line-averaged electron density regardless of the density profile. A key problem in such measurements is the short time delay of the pulse in the plasma (∼1 ns or less for small devices) and, consequently, low accuracy of the measurements of the average density. Various methods for improving the accuracy of such measurements are proposed and implemented in the T-11M experiments. The measurements of the line-averaged density in the T-11M tokamak in the low-density plasma regime are performed. The results obtained agree satisfactorily with interferometric data. The measurement errors are analyzed, and the possibility of using this technique to measure the electron density profile and the position of the plasma column is discussed

  13. Comparison Algorithm Kernels on Support Vector Machine (SVM To Compare The Trend Curves with Curves Online Forex Trading

    Directory of Open Access Journals (Sweden)

    irfan abbas

    2017-01-01

    Full Text Available At this time, the players Forex Trading generally still use the data exchange in the form of a Forex Trading figures from different sources. Thus they only receive or know the data rate of a Forex Trading prevailing at the time just so difficult to analyze or predict exchange rate movements future. Forex players usually use the indicators to enable them to analyze and memperdiksi future value. Indicator is a decision making tool. Trading forex is trading currency of a country, the other country's currency. Trading took place globally between the financial centers of the world with the involvement of the world's major banks as the major transaction. Trading Forex offers profitable investment type with a small capital and high profit, with relatively small capital can earn profits doubled. This is due to the forex trading systems exist leverage which the invested capital will be doubled if the predicted results of buy / sell is accurate, but Trading Forex having high risk level, but by knowing the right time to trade (buy or sell, the losses can be avoided. Traders who invest in the foreign exchange market is expected to have the ability to analyze the circumstances and situations in predicting the difference in currency exchange rates. Forex price movements that form the pattern (curve up and down greatly assist traders in making decisions. The movement of the curve used as an indicator in the decision to purchase (buy or sell (sell. This study compares (Comparation type algorithm kernel on Support Vector Machine (SVM to predict the movement of the curve in live time trading forex using the data GBPUSD, 1H. Results of research on the study of the results and discussion can be concluded that the Kernel Dot, Kernel Multiquaric, Kernel Neural inappropriately used for data is non-linear in the case of data forex to follow the pattern of trend curves, because curves generated curved linear (straight and then to type of kernel is the closest curve

  14. The Effects of Reducing Preparation Time on the Execution of Intentionally Curved Trajectories: Optimization and Geometrical Analysis

    Directory of Open Access Journals (Sweden)

    Dovrat Kohen

    2017-06-01

    Full Text Available When subjects are intentionally preparing a curved trajectory, they are engaged in a time-consuming trajectory planning process that is separate from target selection. To investigate the construction of such a plan, we examined the effect of artificially shortening preparation time on the performance of intentionally curved trajectories using the Timed Response task that enforces initiation of movements prematurely. Fifteen subjects performed obstacle avoidance movements toward one of four targets that were presented 25 or 350 ms before the “go” signal, imposing short and long preparation time conditions with mean values of 170 ms and 493 ms, respectively. While trajectories with short preparation times showed target specificity at their onset, they were significantly more variable and showed larger angular deviations from the lines connecting their initial position and the target, compared to the trajectories with long preparation times. Importantly, the trajectories of the short preparation time movements still reached their end-point targets accurately, with comparable movement durations. We hypothesize that success in the short preparation time condition is a result of an online control mechanism that allows further refinement of the plan during its execution and study this control mechanism with a novel trajectory analysis approach using minimum jerk optimization and geometrical modeling approaches. Results show a later agreement of the short preparation time trajectories with the optimal minimum jerk trajectory, accompanied by a later initiation of a parabolic segment. Both observations are consistent with the existence of an online trajectory planning process.Our results suggest that when preparation time is not sufficiently long, subjects execute a more variable and less optimally prepared initial trajectory and exploit online control mechanisms to refine their actions on the fly.

  15. The Effects of Reducing Preparation Time on the Execution of Intentionally Curved Trajectories: Optimization and Geometrical Analysis

    Science.gov (United States)

    Kohen, Dovrat; Karklinsky, Matan; Meirovitch, Yaron; Flash, Tamar; Shmuelof, Lior

    2017-01-01

    When subjects are intentionally preparing a curved trajectory, they are engaged in a time-consuming trajectory planning process that is separate from target selection. To investigate the construction of such a plan, we examined the effect of artificially shortening preparation time on the performance of intentionally curved trajectories using the Timed Response task that enforces initiation of movements prematurely. Fifteen subjects performed obstacle avoidance movements toward one of four targets that were presented 25 or 350 ms before the “go” signal, imposing short and long preparation time conditions with mean values of 170 ms and 493 ms, respectively. While trajectories with short preparation times showed target specificity at their onset, they were significantly more variable and showed larger angular deviations from the lines connecting their initial position and the target, compared to the trajectories with long preparation times. Importantly, the trajectories of the short preparation time movements still reached their end-point targets accurately, with comparable movement durations. We hypothesize that success in the short preparation time condition is a result of an online control mechanism that allows further refinement of the plan during its execution and study this control mechanism with a novel trajectory analysis approach using minimum jerk optimization and geometrical modeling approaches. Results show a later agreement of the short preparation time trajectories with the optimal minimum jerk trajectory, accompanied by a later initiation of a parabolic segment. Both observations are consistent with the existence of an online trajectory planning process.Our results suggest that when preparation time is not sufficiently long, subjects execute a more variable and less optimally prepared initial trajectory and exploit online control mechanisms to refine their actions on the fly. PMID:28706478

  16. Surface charge method for molecular surfaces with curved areal elements I. Spherical triangles

    Science.gov (United States)

    Yu, Yi-Kuo

    2018-03-01

    Parametrizing a curved surface with flat triangles in electrostatics problems creates a diverging electric field. One way to avoid this is to have curved areal elements. However, charge density integration over curved patches appears difficult. This paper, dealing with spherical triangles, is the first in a series aiming to solve this problem. Here, we lay the ground work for employing curved patches for applying the surface charge method to electrostatics. We show analytically how one may control the accuracy by expanding in powers of the the arc length (multiplied by the curvature). To accommodate not extremely small curved areal elements, we have provided enough details to include higher order corrections that are needed for better accuracy when slightly larger surface elements are used.

  17. Restenosis in coronary bare metal stents. Importance of time to follow-up: a comparison of coronary angiograms 6 months and 4 years after implantation

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Helqvist, Steffen; Kløvgaard, Lene

    2008-01-01

    Objectives. Angiographic late lumen loss measured 6 to 9 month after bare metal stent implantation in the coronary arteries is a validated restenosis parameter. Design. We performed a second angiographic follow-up after 4 years in event free survivors from the DANSTENT trial cohort. Results......-sectional vessel area and a 39% reduction of the binary restenosis rate over time. Conclusions. Instent late lumen loss in bare metal stents decreases spontaneously over time. Maturation of early hyperplastic tissue reaction after stent implantation with subsequent thinning of fibrotic tissue might explain...

  18. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    Science.gov (United States)

    Binder, Ronald K; Leipsic, Jonathon; Wood, David; Moore, Teri; Toggweiler, Stefan; Willson, Alex; Gurvitch, Ronen; Freeman, Melanie; Webb, John G

    2012-04-01

    Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. Forty patients undergoing transfemoral TAVR at St Paul's Hospital, Vancouver, Canada, were evaluated. All underwent preimplant 3DA and 68% underwent preimplant MDCT. Three-dimensional angiographic reconstructions were generated from images of a C-arm rotational aortic root angiogram during breath-hold, rapid ventricular pacing, and injection of 32 mL contrast medium at 8 mL/s. Two independent operators prospectively predicted perpendicular valve projections. The implant angle was chosen at the discretion of the physician performing TAVR. The angles from 3DA, from MDCT, the implant angle, and the postdeployment perpendicular prosthesis view were compared. The shortest distance from the postdeployment perpendicular prosthesis projection to the regression line of predicted perpendicular projections was calculated. All but 1 patient had adequate image quality for reproducible angle predictions. There was a significant correlation between 3DA and MDCT for prediction of perpendicular valve projections (r=0.682, Pregression line of predicted angles to the postdeployment prosthesis view was 5.1±4.6° for 3DA and 7.9±4.9° for MDCT (P=0.01). Three-dimensional angiographic reconstructions and MDCT are safe, practical, and accurate imaging modalities for identifying the optimal perpendicular valve deployment projection during TAVR.

  19. Correlation of C-Reactive Protein and Cardiac Enzymes with Angiographic Severity of Coronary Artery Disease in Pakistani Patients with Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Saleem, A.; Ali, A.

    2017-01-01

    Objective: To determine the correlation of C-reactive protein (CRP) levels with the severity of coronary stenosis on angiography and the association of cardiac enzymes with the degree of stenosis in acute coronary syndrome (ACS) patients. Secondly, to compare association of angiographic severity of vascular stenosis with CRP in patients with ST segment elevation myocardial infarction (STEMI) and non-STEMI / Unstable angina (UA). Study Design: Prospective, descriptive study. Place and Duration of Study: Khan Research Laboratories (KRL) Hospital, from October 2014 to March 2015. Methodology: CRP was measured on diagnosis of ACS in 70 patients. Cardiac enzymes were measured 6 hours after the onset of chest pain. Angiographic scoring for degree of stenosis and number of culprit vessels was done. Two groups consisting of patients with STEMI (group 1) and with NSTEMI/UA (group 2) were made. Results: No correlation was found between CRP levels and angiographic stenosis in patients with ACS (r=0.162, p>0.05). No association was found between eosinophil count and severity of stenosis (p=0.88). Rise of cardiac enzymes and degree of coronary stenosis showed a positive correlation (p <0.001). There was significant difference in the means of coronary artery stenosis scores between the two groups (Gensini score of groups 1 and 2: 35.9 +- 4 and 14 +- 8, respectively) p<0.001, but there was no significant difference in CRP levels. Conclusion: CRP is a marker of inflammation in ACS rather than a risk factor for determining the severity of vascular stenosis. Rise in cardiac enzymes still grade high in predicting severity of vascular stenosis than eosinophil count or CRP levels. (author)

  20. Intractable epistaxis: which arteries are responsible? An angiographic study.

    Science.gov (United States)

    de Bonnecaze, Guillaume; Gallois, Y; Chaynes, P; Bonneville, F; Dupret-Bories, A; Chantalat, E; Serrano, E

    2017-11-01

    Epistaxis constitutes a significant proportion of the Otolaryngologist's emergency workload. Optimal management differs in relation to the anatomic origin of the bleeding. The outcome of our study was to determine which artery(ies) could be considered as the cause of severe bleeding in the context of severe epistaxis. Fifty-five procedures of embolization preceded by angiography were reviewed. Medical records of interventionally treated patients were analysed for demographics, medical history, risk factors and clinical data. Angiographic findings were also assessed for active contrast extravasation (blush), vascular abnormality and embolised artery. Previous angiography showed an active contrast extravasation in only 20 procedures. The most common bleeding source was the sphenopalatine artery (SPA) followed by anterior ethmoïdal artery (AEA) and facial artery. Majority of multiple or bilateral extravasations occured in patients with systemic factors. A better understanding of the potential bleeding source might help and limit the risk of treatment failures. Our study confirms that the SPA is the most common cause of severe bleeding. We also emphasise the role of the AEA not only in traumatic context. Others arteries are rarely involved except in patients with comorbidities or frequent recurrences.

  1. Correlation Between Contrast Time-Density Time on Digital Subtraction Angiography and Flow: An in Vitro Study.

    Science.gov (United States)

    Brunozzi, Denise; Shakur, Sophia F; Ismail, Rahim; Linninger, Andreas; Hsu, Chih-Yang; Charbel, Fady T; Alaraj, Ali

    2018-02-01

    Digital subtraction angiography (DSA) provides an excellent anatomic characterization of cerebral vasculature, but hemodynamic assessment is often qualitative and subjective. Various clinical algorithms have been produced to semiquantify flow from the data obtained from DSA, but few have tested them against reliable flow values. An arched flow model was created and injected with contrast material. Seventeen injections were acquired in anterior-posterior and lateral DSA projections, and 4 injections were acquired in oblique projection. Image intensity change over the angiogram cycle of each DSA run was analyzed through a custom MATLAB code. Time-density plots obtained were divided into 3 components (time-density times, TDTs): TDT 10%-100% (time needed for contrast material to change image intensity from 10% to 100%), TDT 100%-10% (time needed for contrast material to change image intensity from 100% to 10%), and TDT 25%-25% (time needed for contrast material to change from 25% image intensity to 25%). Time-density index (TDI) was defined as model cross-sectional area to TDT ratio, and it was measured against different flow rates. TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% all correlated significantly with flow (P < 0.001). TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% showed, respectively, a correlation coefficient of 0.91, 0.91, and 0.97 in the anterior-posterior DSA projections (P < 0.001). In the lateral DSA projection, TDI 100%-10% showed a weaker correlation (r = 0.57; P = 0.03). Also in the oblique DSA projection, TDIs correlated significantly with flow. TDI on DSA correlates significantly with flow. Although in vitro studies might overlook conditions that occur in patients, this method appears to correlate with the flow and could offer a semiquantitative method to evaluate the cerebral blood flow. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. On the choice of lens density profile in time delay cosmography

    Science.gov (United States)

    Sonnenfeld, Alessandro

    2018-03-01

    Time delay lensing is a mature and competitive cosmological probe. However, it is limited in accuracy by the well-known problem of the mass-sheet degeneracy: too rigid assumptions on the density profile of the lens can potentially bias the inference on cosmological parameters. I investigate the degeneracy between the choice of the lens density profile and the inference on the Hubble constant, focusing on double image systems. By expanding lensing observables in terms of the local derivatives of the lens potential around the Einstein radius, and assuming circular symmetry, I show that 3 degrees of freedom in the radial direction are necessary to achieve a few per cent accuracy in the time-delay distance. Additionally, while the time delay is strongly dependent on the second derivative of the potential, observables typically used to constrain lens models in time-delay studies, such as image position and radial magnification information, are mostly sensitive to the first and third derivatives, making it very challenging to accurately determine time-delay distances with lensing data alone. Tests on mock observations show that the assumption of a power-law density profile results in a 5 per cent average bias on H0, with a 6 per cent scatter. Using a more flexible model and adding unbiased velocity dispersion constraints allows me to obtain an inference with 1 per cent accuracy. A power-law model can still provide 3 per cent accuracy if velocity dispersion measurements are used to constrain its slope. Although this study is based on the assumption of axisymmetry, its main findings can be generalized to cases with moderate ellipticity.

  3. The effect of respiratory induced density variations on non-TOF PET quantitation in the lung

    Science.gov (United States)

    Holman, Beverley F.; Cuplov, Vesna; Hutton, Brian F.; Groves, Ashley M.; Thielemans, Kris

    2016-04-01

    Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant 18F-FDG and 18F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung.

  4. The effect of respiratory induced density variations on non-TOF PET quantitation in the lung

    International Nuclear Information System (INIS)

    Holman, Beverley F; Cuplov, Vesna; Hutton, Brian F; Groves, Ashley M; Thielemans, Kris

    2016-01-01

    Accurate PET quantitation requires a matched attenuation map. Obtaining matched CT attenuation maps in the thorax is difficult due to the respiratory cycle which causes both motion and density changes. Unlike with motion, little attention has been given to the effects of density changes in the lung on PET quantitation. This work aims to explore the extent of the errors caused by pulmonary density attenuation map mismatch on dynamic and static parameter estimates. Dynamic XCAT phantoms were utilised using clinically relevant 18 F-FDG and 18 F-FMISO time activity curves for all organs within the thorax to estimate the expected parameter errors. The simulations were then validated with PET data from 5 patients suffering from idiopathic pulmonary fibrosis who underwent PET/Cine-CT. The PET data were reconstructed with three gates obtained from the Cine-CT and the average Cine-CT. The lung TACs clearly displayed differences between true and measured curves with error depending on global activity distribution at the time of measurement. The density errors from using a mismatched attenuation map were found to have a considerable impact on PET quantitative accuracy. Maximum errors due to density mismatch were found to be as high as 25% in the XCAT simulation. Differences in patient derived kinetic parameter estimates and static concentration between the extreme gates were found to be as high as 31% and 14%, respectively. Overall our results show that respiratory associated density errors in the attenuation map affect quantitation throughout the lung, not just regions near boundaries. The extent of this error is dependent on the activity distribution in the thorax and hence on the tracer and time of acquisition. Consequently there may be a significant impact on estimated kinetic parameters throughout the lung. (paper)

  5. Time-dependent internal density functional theory formalism and Kohn-Sham scheme for self-bound systems

    International Nuclear Information System (INIS)

    Messud, Jeremie

    2009-01-01

    The stationary internal density functional theory (DFT) formalism and Kohn-Sham scheme are generalized to the time-dependent case. It is proven that, in the time-dependent case, the internal properties of a self-bound system (such as an atomic nuclei or a helium droplet) are all defined by the internal one-body density and the initial state. A time-dependent internal Kohn-Sham scheme is set up as a practical way to compute the internal density. The main difference from the traditional DFT formalism and Kohn-Sham scheme is the inclusion of the center-of-mass correlations in the functional.

  6. [Multiple linear regression and ROC curve analysis of the factors of lumbar spine bone mineral density].

    Science.gov (United States)

    Zhang, Xiaodong; Zhao, Yinxia; Hu, Shaoyong; Hao, Shuai; Yan, Jiewen; Zhang, Lingyan; Zhao, Jing; Li, Shaolin

    2015-09-01

    To investigate the correlation between the lumbar vertebra bone mineral density (BMD) and age, gender, height, weight, body mass index, waistline, hipline, bone marrow and abdomen fat, and to explore the key factor affecting the BMD. A total of 72 cases were randomly recruited. All the subjects underwent a spectroscopic examination of the third lumber vertebra with single-voxel method in 1.5T MR. Lipid fractions (FF%) were measured. Quantitative CT were also performed to get the BMD of L3 and the corresponding abdomen subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT). The statistical analysis were performed by SPSS 19.0. Multiple linear regression showed except the age and FF% showed significant difference (P0.05). The correlation of age and FF% with BMD was statistically negatively significant (r=-0.830, -0.521, P<0.05). The ROC curve analysis showed that the sensitivety and specificity of predicting osteoporosis were 81.8% and 86.9%, with a threshold of 58.5 years old. And it showed that the sensitivety and specificity of predicting osteoporosis were 90.9% and 55.7%, with a threshold of 52.8% for FF%. The lumbar vertebra BMD was significantly and negatively correlated with age and bone marrow FF%, but it was not significantly correlated with gender, height, weight, BMI, waistline, hipline, SAT and VAT. And age was the critical factor.

  7. Digital tomosynthesis for evaluating metastatic lung nodules: nodule visibility, learning curves, and reading times.

    Science.gov (United States)

    Lee, Kyung Hee; Goo, Jin Mo; Lee, Sang Min; Park, Chang Min; Bahn, Young Eun; Kim, Hyungjin; Song, Yong Sub; Hwang, Eui Jin

    2015-01-01

    To evaluate nodule visibility, learning curves, and reading times for digital tomosynthesis (DT). We included 80 patients who underwent computed tomography (CT) and DT before pulmonary metastasectomy. One experienced chest radiologist annotated all visible nodules on thin-section CT scans using computer-aided detection software. Two radiologists used CT as the reference standard and retrospectively graded the visibility of nodules on DT. Nodule detection performance was evaluated in four sessions of 20 cases each by six readers. After each session, readers were unblinded to the DT images by revealing the true-positive markings and were instructed to self-analyze their own misreads. Receiver-operating-characteristic curves were determined. Among 414 nodules on CT, 53.3% (221/414) were visible on DT. The main reason for not seeing a nodule on DT was small size (93.3%, ≤ 5 mm). DT revealed a substantial number of malignant nodules (84.1%, 143/170). The proportion of malignant nodules among visible nodules on DT was significantly higher (64.7%, 143/221) than that on CT (41.1%, 170/414) (p 0.8, and the average detection rate for malignant nodules was 85% (210/246). The inter-session analysis of the AUC showed no significant differences among the readers, and the detection rate for malignant nodules did not differ across sessions. A slight improvement in reading times was observed. Most malignant nodules > 5 mm were visible on DT. As nodule detection performance was high from the initial session, DT may be readily applicable for radiology residents and board-certified radiologists.

  8. Modeling L2,3-Edge X-ray Absorption Spectroscopy with Real-Time Exact Two-Component Relativistic Time-Dependent Density Functional Theory.

    Science.gov (United States)

    Kasper, Joseph M; Lestrange, Patrick J; Stetina, Torin F; Li, Xiaosong

    2018-04-10

    X-ray absorption spectroscopy is a powerful technique to probe local electronic and nuclear structure. There has been extensive theoretical work modeling K-edge spectra from first principles. However, modeling L-edge spectra directly with density functional theory poses a unique challenge requiring further study. Spin-orbit coupling must be included in the model, and a noncollinear density functional theory is required. Using the real-time exact two-component method, we are able to variationally include one-electron spin-orbit coupling terms when calculating the absorption spectrum. The abilities of different basis sets and density functionals to model spectra for both closed- and open-shell systems are investigated using SiCl 4 and three transition metal complexes, TiCl 4 , CrO 2 Cl 2 , and [FeCl 6 ] 3- . Although we are working in the real-time framework, individual molecular orbital transitions can still be recovered by projecting the density onto the ground state molecular orbital space and separating contributions to the time evolving dipole moment.

  9. Optical properties of Al nanostructures from time dependent density functional theory

    KAUST Repository

    Mokkath, Junais Habeeb; Schwingenschlö gl, Udo

    2016-01-01

    The optical properties of Al nanostructures are investigated by means of time dependent density functional theory, considering chains of varying length and ladders/stripes of varying aspect ratio. The absorption spectra show redshifting

  10. External force back-projective composition and globally deformable optimization for 3-D coronary artery reconstruction

    International Nuclear Information System (INIS)

    Yang, Jian; Cong, Weijian; Fan, Jingfan; Liu, Yue; Wang, Yongtian; Chen, Yang

    2014-01-01

    The clinical value of the 3D reconstruction of a coronary artery is important for the diagnosis and intervention of cardiovascular diseases. This work proposes a method based on a deformable model for reconstructing coronary arteries from two monoplane angiographic images acquired from different angles. First, an external force back-projective composition model is developed to determine the external force, for which the force distributions in different views are back-projected to the 3D space and composited in the same coordinate system based on the perspective projection principle of x-ray imaging. The elasticity and bending forces are composited as an internal force to maintain the smoothness of the deformable curve. Second, the deformable curve evolves rapidly toward the true vascular centerlines in 3D space and angiographic images under the combination of internal and external forces. Third, densely matched correspondence among vessel centerlines is constructed using a curve alignment method. The bundle adjustment method is then utilized for the global optimization of the projection parameters and the 3D structures. The proposed method is validated on phantom data and routine angiographic images with consideration for space and re-projection image errors. Experimental results demonstrate the effectiveness and robustness of the proposed method for the reconstruction of coronary arteries from two monoplane angiographic images. The proposed method can achieve a mean space error of 0.564 mm and a mean re-projection error of 0.349 mm. (paper)

  11. F(α) curves: Experimental results

    International Nuclear Information System (INIS)

    Glazier, J.A.; Gunaratne, G.; Libchaber, A.

    1988-01-01

    We study the transition to chaos at the golden and silver means for forced Rayleigh-Benard (RB) convection in mercury. We present f(α) curves below, at, and above the transition, and provide comparisons to the curves calculated for the one-dimensional circle map. We find good agreement at both the golden and silver means. This confirms our earlier observation that for low amplitude forcing, forced RB convection is well described by the one-dimensional circle map and indicates that the f(α) curve is a good measure of the approach to criticality. For selected subcritical experimental data sets we calculate the degree of subcriticality. We also present both experimental and calculated results for f(α) in the presence of a third frequency. Again we obtain agreement: The presence of random noise or a third frequency narrows the right-hand (negative q) side of the f(α) curve. Subcriticality results in symmetrically narrowed curves. We can also distinguish these cases by examining the power spectra and Poincare sections of the time series

  12. Density perturbations due to the inhomogeneous discrete spatial structure of space-time

    International Nuclear Information System (INIS)

    Wolf, C.

    1998-01-01

    For the case that space-time permits an inhomogeneous discrete spatial structure due to varying gravitational fields or a foam-like structure of space-time, it is demonstrated that thermodynamic reasoning implies that matter-density perturbations will arise in the early universe

  13. Intracranial infective aneurysms presenting with haemorrhage: An analysis of angiographic findings, management and outcome

    International Nuclear Information System (INIS)

    Venkatesh, Sudhakar K.; Phadke, Rajendra V.; Kalode, Ravi R.; Kumar, Sunil; Jain, Vijendra K.

    2000-01-01

    AIM: This study is an analysis of angiographic findings in 17 patients with infective aneurysms who presented with intracranial haemorrhage and reviews the management and outcome in the context of the existing literature. MATERIALS AND METHODS: A retrospective study of infective aneurysms in 17 patients was carried out. Cranial angiography was performed in all patients. The location, size and outline of aneurysms were analysed. Ten patients were managed conservatively and six patients underwent surgery for the ruptured infective aneurysms and were followed up for a period of 35.8 months and 23 months, respectively. RESULTS: Twenty-two aneurysms were identified (five unruptured) in 17 patients. Twenty aneurysms (90.9%) were distal in location and two (9.1%) proximal. Sixty percent were in the posterior circulation with 55% in the posterior cerebral artery (PCA) territory, 27.3% in the middle cerebral artery (MCA) territory and 9.1% in the anterior cerebral artery (ACA) territory. Fourteen aneurysms were small (3-5 mm) and eight were medium sized (6-9 mm). 72.7% of aneurysms had irregular outline and 27.3% regular outline. Out of the 10 ruptured aneurysms managed conservatively, eight resolved. One patient died, presumably due to rebleed, and one had infarction due to parent vessel thrombosis. Six aneurysms were surgically managed with good results. Of the five unruptured aneurysms one was surgically managed and the remaining four conservatively managed patients did not bleed during follow-up. CONCLUSION: Patients with ruptured infective aneurysms fared well with medical management and the outcome in this series is better than that reported in literature. Patients on conservative management, however, need closer monitoring with angiographic follow-up. Active management is required with enlarging or persisting aneurysms. Venkatesh, S.K. (2000)

  14. A simple method to calculate first-passage time densities with arbitrary initial conditions

    Science.gov (United States)

    Nyberg, Markus; Ambjörnsson, Tobias; Lizana, Ludvig

    2016-06-01

    Numerous applications all the way from biology and physics to economics depend on the density of first crossings over a boundary. Motivated by the lack of general purpose analytical tools for computing first-passage time densities (FPTDs) for complex problems, we propose a new simple method based on the independent interval approximation (IIA). We generalise previous formulations of the IIA to include arbitrary initial conditions as well as to deal with discrete time and non-smooth continuous time processes. We derive a closed form expression for the FPTD in z and Laplace-transform space to a boundary in one dimension. Two classes of problems are analysed in detail: discrete time symmetric random walks (Markovian) and continuous time Gaussian stationary processes (Markovian and non-Markovian). Our results are in good agreement with Langevin dynamics simulations.

  15. Design and implementation of a simple on-line time-activity curve detector for [O-15] water PET studies

    International Nuclear Information System (INIS)

    Wollenweber, S.D.; Hichwa, R.D.; Ponto, L.L.B.

    1996-01-01

    A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAC) for water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve is unnecessary. The positrons emanating from a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is shielded by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) calculated from the TAC determined by 1-second automated sampling was compared to that calculated from every 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector

  16. Benchmarks for electronically excited states: Time-dependent density functional theory and density functional theory based multireference configuration interaction

    DEFF Research Database (Denmark)

    Silva-Junior, Mario R.; Schreiber, Marko; Sauer, Stephan P. A.

    2008-01-01

    Time-dependent density functional theory (TD-DFT) and DFT-based multireference configuration interaction (DFT/MRCI) calculations are reported for a recently proposed benchmark set of 28 medium-sized organic molecules. Vertical excitation energies, oscillator strengths, and excited-state dipole...

  17. Timing of hormone therapy, type of menopause, and coronary disease in women: data from the National Heart, Lung, and Blood Institute-sponsored Women's Ischemia Syndrome Evaluation.

    Science.gov (United States)

    Shufelt, Chrisandra L; Johnson, B Delia; Berga, Sarah L; Braunstein, Glenn D; Reis, Steven E; Bittner, Vera; Yang, YuChing; Pepine, Carl J; Sharaf, Barry L; Sopko, George; Kelsey, Sheryl F; Merz, C Noel Bairey

    2011-09-01

    The aim of this study was to assess the relationship of the timing of hormone therapy (HT) use with angiographic coronary artery disease (CAD) and cardiovascular disease (CVD) events in women with natural versus surgical menopause. We studied 654 postmenopausal women undergoing coronary angiography for the evaluation of suspected ischemia. Timing and type of menopause, HT use, and quantitative angiographic evaluations were obtained at baseline, and the women were followed for a median of 6 years for CVD events. Ever users of HT had a significantly lower prevalence of obstructive CAD compared with never users (age-adjusted odds ratio, 0.41 [0.28-0.60]). Women with natural menopause initiating HT before age 55 years had lower CAD severity compared with never users (age-adjusted β [SE] = -6.23 [1.50], P menopause group (hazard ratio [95% CI], 0.60 [0.41-0.88]; P = 0.009) but became nonsignificant when adjusted for the presence or severity of obstructive CAD. Using the quantitative measurements of the timing and type of menopause and HT use, earlier initiation of HT was associated with less angiographic CAD in women with natural but not surgical menopause. Our data suggest that the effect of HT use on reduced cardiovascular event rates is mediated by the presence or absence of angiographic obstructive atherosclerosis.

  18. Optimal use of directional coronary atherectomy is required to ensure long-term angiographic benefit: a study with matched procedural outcome after atherectomy and angioplasty

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); D.T.J. Keane (David); R. Melkert (Rein); P.W.J.C. Serruys (Patrick); D.P. Foley (David); H. Boersma (Eric)

    1994-01-01

    textabstractOBJECTIVES. This study was designed to examine whether restenosis is related to the extent or mechanism of lumen improvement and to explore angiographic determinants of optimal atherectomy. BACKGROUND. Directional atherectomy induces a greater extent of immediate gain and late loss but

  19. Highway travel time information system based on cumulative count curves and new tracking technologies

    Energy Technology Data Exchange (ETDEWEB)

    Soriguera Marti, F.; Martinez-Diaz, M.; Perez Perez, I.

    2016-07-01

    Travel time is probably the most important indicator of the level of service of a highway, and it is also the most appreciated information for its users. Administrations and private companies make increasing efforts to improve its real time estimation. The appearance of new technologies makes the precise measurement of travel times easier than never before. However, direct measurements of travel time are, by nature, outdated in real time, and lack of the desired forecasting capabilities. This paper introduces a new methodology to improve the real time estimation of travel times by using the equipment usually present in most highways, i.e., loop detectors, in combination with Automatic Vehicle Identification or Tracking Technologies. One of the most important features of the method is the usage of cumulative counts at detectors as an input, avoiding the drawbacks of common spot-speed methodologies. Cumulative count curves have great potential for freeway travel time information systems, as they provide spatial measurements and thus allow the calculation of instantaneous travel times. In addition, they exhibit predictive capabilities. Nevertheless, they have not been used extensively mainly because of the error introduced by the accumulation of the detector drift. The proposed methodology solves this problem by correcting the deviations using direct travel time measurements. The method results highly beneficial for its accuracy as well as for its low implementation cost. (Author)

  20. The Effect of Velocity Correlation on the Spatial Evolution of Breakthrough Curves in Heterogeneous Media

    Science.gov (United States)

    Massoudieh, A.; Dentz, M.; Le Borgne, T.

    2017-12-01

    In heterogeneous media, the velocity distribution and the spatial correlation structure of velocity for solute particles determine the breakthrough curves and how they evolve as one moves away from the solute source. The ability to predict such evolution can help relating the spatio-statistical hydraulic properties of the media to the transport behavior and travel time distributions. While commonly used non-local transport models such as anomalous dispersion and classical continuous time random walk (CTRW) can reproduce breakthrough curve successfully by adjusting the model parameter values, they lack the ability to relate model parameters to the spatio-statistical properties of the media. This in turns limits the transferability of these models. In the research to be presented, we express concentration or flux of solutes as a distribution over their velocity. We then derive an integrodifferential equation that governs the evolution of the particle distribution over velocity at given times and locations for a particle ensemble, based on a presumed velocity correlation structure and an ergodic cross-sectional velocity distribution. This way, the spatial evolution of breakthrough curves away from the source is predicted based on cross-sectional velocity distribution and the connectivity, which is expressed by the velocity transition probability density. The transition probability is specified via a copula function that can help construct a joint distribution with a given correlation and given marginal velocities. Using this approach, we analyze the breakthrough curves depending on the velocity distribution and correlation properties. The model shows how the solute transport behavior evolves from ballistic transport at small spatial scales to Fickian dispersion at large length scales relative to the velocity correlation length.

  1. Wood fibre density measurement with 238 Pu radiation

    International Nuclear Information System (INIS)

    Barry, B.J.; Baker, D.B.

    1996-01-01

    The form of the curve of attenuation by wood fibre of the X radiation from 238 Pu has been determined. An exponential function containing a term second order in the areal density of the fibre described the curve accurately. The effect of scatter is negligible, even with an uncollimated radiation beam. (author). 18 refs., 1 tab., 6 figs

  2. Statistical analysis of time-resolved emission from ensembles of semiconductor quantum dots: Interpretation of exponential decay models

    DEFF Research Database (Denmark)

    Van Driel, A.F.; Nikolaev, I.S.; Vergeer, P.

    2007-01-01

    We present a statistical analysis of time-resolved spontaneous emission decay curves from ensembles of emitters, such as semiconductor quantum dots, with the aim of interpreting ubiquitous non-single-exponential decay. Contrary to what is widely assumed, the density of excited emitters...... and the intensity in an emission decay curve are not proportional, but the density is a time integral of the intensity. The integral relation is crucial to correctly interpret non-single-exponential decay. We derive the proper normalization for both a discrete and a continuous distribution of rates, where every...... decay component is multiplied by its radiative decay rate. A central result of our paper is the derivation of the emission decay curve when both radiative and nonradiative decays are independently distributed. In this case, the well-known emission quantum efficiency can no longer be expressed...

  3. Long time-scale density peaking in JET

    International Nuclear Information System (INIS)

    Sartori, R.; Saibene, G.; Becoulet, M.

    2002-01-01

    This paper discusses how the proximity to the L-H threshold affects the confinement of ELMy H-modes at high density. The largest reduction in confinement at high density is observed at the transition from the Type I to the Type III ELMy regime. At medium plasma triangularity, δ≅0.3 (where δ is the average triangularity at the separatrix), JET experiments show that, by increasing the margin above the L-H threshold power and maintaining the edge temperature above the critical temperature for the transition to Type III ELMs, it is possible to avoid the degradation of the pedestal pressure with density, normally observed at lower power. As a result, the range of achievable densities (both in the core and in the pedestal) is increased. At high power above the L-H threshold power the core density was equal to the Greenwald limit with H97≅0.9. There is evidence that a mixed regime of Type I and Type II ELMs has been obtained at this intermediate triangularity, possibly as a result of this increase in density. At higher triangularity, δ≅0.5, the power required to achieve similar results is lower. (author)

  4. Evaluation of the angiographic findings in pulmonary atresia

    International Nuclear Information System (INIS)

    Choe, Kyu Ok; Sul, Jun Hee; Lee, Seung Kyu; Cho, Bum Koo; Hong, Pill Whoon

    1986-01-01

    We studied the angiographic findings in 65 patients with congenital pulmonary atresia, ages 4 days to 14 years (mean 3.3 yrs), from 1981 to 1986 at Severance Hospital Yonsei University. 1. 6 had pulmonary atresia with an intact interventricular septum, 38 had it with cardiac anomaly Renodynamically simulating TOF, and 21 associated with more complicated cardiac anomalies. 2. In the group with an intact ventricular septum, 5 showed confluent intrapericardial pulmonary artery, all segmental pulmonary arteries connected to intrapericardial artery. 3. In the group simulating TOF, aorta arose from RV with or without overriding in 35. In 27 patients with confluent intrapericardial pulmonary artery, 23 had more than 10 segmental pulmonary arteries connected to intrapericardial artery and 5 had severely hypoplastic hilar pulmonary arteries. In 11 with non confluent intrapericardial pulmonary artery, 4 had more than 10 segmental pulmonary arteries connected to central pulmonary artery and 9 had severely hypoplastic hilar pulmonary arteries. 4. In the group associated with more complicated cardiac anomaly, included 8 patients with atrioventricular discordance, 7 with univentricular heart and 6 with tricuspid atresia. In 17 patients with confluent intrapericardial artery, 16 had more than 10 segmental pulmonary arteries connected to intrapericardial artery, one showed severe hypoplasia of hilar pulmonary arteries. In another 4 with non confluence, no one showed more than 10 segmental arteries connected to intrapericardial or hilar pulmonary artery.

  5. Time-dependent density-functional theory concepts and applications

    CERN Document Server

    Ullrich, Carsten A

    2011-01-01

    Time-dependent density-functional theory (TDDFT) describes the quantum dynamics of interacting electronic many-body systems formally exactly and in a practical and efficient manner. TDDFT has become the leading method for calculating excitation energies and optical properties of large molecules, with accuracies that rival traditional wave-function based methods, but at a fraction of the computational cost.This book is the first graduate-level text on the concepts and applications of TDDFT, including many examples and exercises, and extensive coverage of the literature. The book begins with a s

  6. Light Curve Analysis of SAO23229

    Directory of Open Access Journals (Sweden)

    Ho-Il Kim

    1993-06-01

    Full Text Available We have made UBV light curves of a newly discovered eclipsing binary, SAO23229 at Sobaeksan Astronomy Observatory. We determined a minimum light time of HJD2448636.1170+/-0.0005 that is 3 minutes later than predicted time, and founda peculiar light variation at phase 0.75 that may not be secondary eclipse. Orbital period of SAO23229 would be 4.2 days rather than 2.1 days. Our analysis of the light curves shows that SAO23229 has a detached configuration consisting of two almost identical F type main sequence stars.

  7. Multi-configuration time-dependent density-functional theory based on range separation

    DEFF Research Database (Denmark)

    Fromager, E.; Knecht, S.; Jensen, Hans Jørgen Aagaard

    2013-01-01

    Multi-configuration range-separated density-functional theory is extended to the time-dependent regime. An exact variational formulation is derived. The approximation, which consists in combining a long-range Multi-Configuration- Self-Consistent Field (MCSCF) treatment with an adiabatic short...... (srGGA) approximations. As expected, when modeling long-range interactions with the MCSCF model instead of the adiabatic Buijse-Baerends density-matrix functional as recently proposed by Pernal [J. Chem. Phys. 136, 184105 (2012)10.1063/1.4712019], the description of both the 1D doubly-excited state...

  8. Optimized effective potential in real time: Problems and prospects in time-dependent density-functional theory

    International Nuclear Information System (INIS)

    Mundt, Michael; Kuemmel, Stephan

    2006-01-01

    The integral equation for the time-dependent optimized effective potential (TDOEP) in time-dependent density-functional theory is transformed into a set of partial-differential equations. These equations only involve occupied Kohn-Sham orbitals and orbital shifts resulting from the difference between the exchange-correlation potential and the orbital-dependent potential. Due to the success of an analog scheme in the static case, a scheme that propagates orbitals and orbital shifts in real time is a natural candidate for an exact solution of the TDOEP equation. We investigate the numerical stability of such a scheme. An approximation beyond the Krieger-Li-Iafrate approximation for the time-dependent exchange-correlation potential is analyzed

  9. Angiographic Embolization of a Postpartum Vulvovaginal Hematoma in a Patient with Situs Inversus Totalis: An Effective Second-Line Treatment

    Directory of Open Access Journals (Sweden)

    Elias M. Dahdouh

    2013-01-01

    Full Text Available Situs inversus totalis is a rare congenital anomaly where asymmetrical positioning of internal organs may affect the surgical and radiological management of certain conditions. Vulvovaginal hematoma is a life-threatening complication of vaginal delivery whose primary treatment usually consists of incision and drainage of the hematoma and ligation of the responsible vessels, followed by wound packing. Failure of these measures to control the bleeding was previously considered as an indication for laparotomy to perform bilateral hypogastric artery ligation and, if needed, a hysterectomy. Relative to major abdominal surgery, selective percutaneous angiographic embolization offers considerable advantages and significant less morbidity. Indeed, angiographic embolization is routinely used as a measure to control refractory pelvic bleeding, though the literature and experience in women with situs inversus totalis are scarce. In this paper, we report a case of postpartum vulvovaginal hematoma in a patient with situs inversus, refractory to conventional treatment, where arteriographic embolization was successfully used to control the bleeding. The management of this obstetrical complication and the use of this minimally invasive technique are also reviewed. To the best of our knowledge, this is the first report in the literature describing the feasibility of this technique in a patient with situs inversus totalis.

  10. On renormalisation of the quantum stress tensor in curved space-time by dimensional regularisation

    International Nuclear Information System (INIS)

    Bunch, T.S.

    1979-01-01

    Using dimensional regularisation, a prescription is given for obtaining a finite renormalised stress tensor in curved space-time. Renormalisation is carried out by renormalising coupling constants in the n-dimensional Einstein equation generalised to include tensors which are fourth order in derivatives of the metric. Except for the special case of a massless conformal field in a conformally flat space-time, this procedure is not unique. There exists an infinite one-parameter family of renormalisation ansatze differing from each other in the finite renormalisation that takes place. Nevertheless, the renormalised stress tensor for a conformally invariant field theory acquires a nonzero trace which is independent of the renormalisation ansatz used and which has a value in agreement with that obtained by other methods. A comparison is made with some earlier work using dimensional regularisation which is shown to be in error. (author)

  11. Elementary particles in curved spaces

    International Nuclear Information System (INIS)

    Lazanu, I.

    2004-01-01

    The theories in particle physics are developed currently, in Minkowski space-time starting from the Poincare group. A physical theory in flat space can be seen as the limit of a more general physical theory in a curved space. At the present time, a theory of particles in curved space does not exist, and thus the only possibility is to extend the existent theories in these spaces. A formidable obstacle to the extension of physical models is the absence of groups of motion in more general Riemann spaces. A space of constant curvature has a group of motion that, although differs from that of a flat space, has the same number of parameters and could permit some generalisations. In this contribution we try to investigate some physical implications of the presumable existence of elementary particles in curved space. In de Sitter space (dS) the invariant rest mass is a combination of the Poincare rest mass and the generalised angular momentum of a particle and it permits to establish a correlation with the vacuum energy and with the cosmological constant. The consequences are significant because in an experiment the local structure of space-time departs from the Minkowski space and becomes a dS or AdS space-time. Discrete symmetry characteristics of the dS/AdS group suggest some arguments for the possible existence of the 'mirror matter'. (author)

  12. Scanning the melting curve of tungsten by a submicrosecond wire-explosion experiment

    International Nuclear Information System (INIS)

    Kloss, A.; Hess, H.; Schneidenbach, H.; Grossjohann, R.

    1999-01-01

    Measurements of temperature and density during a wire-explosion experiment at atmospheric pressure are described. The measurements encompass a parameter range from the solid to near the critical point. The influence of a polytetra-fluoroethylene coating of the wire, necessary to prevent surface discharges, on the temperature and density measurements is investigated. The melting curve of tungsten up to 4,000 K is determined

  13. Maitra-Burke example of initial-state dependence in time-dependent density-functional theory

    International Nuclear Information System (INIS)

    Holas, A.; Balawender, R.

    2002-01-01

    In a recent paper, Maitra and Burke [Phys. Rev. A 63, 042501 (2001); 64, 039901(E) (2001)] have given an interesting and instructive example that illustrates a specific feature of the time-dependent density-functional theory--the dependence of the reconstructed time-dependent potential not only on the electron density, but also on the initial state of the system. However, a concise form of its presentation by these authors is insufficient to reveal all its peculiarities. Our paper represents a very detailed study of this valuable example, intended to facilitate a better understanding and appreciation

  14. Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus

    Directory of Open Access Journals (Sweden)

    Koprowski Robert

    2012-06-01

    Full Text Available Abstract Background The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc. Methods The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension. Results The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method. Conclusions This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number.

  15. Determination of water retention curves of concrete

    International Nuclear Information System (INIS)

    Villar, M.V.; Romero, F.J.

    2015-01-01

    The water retention curves of concrete and mortar obtained with two different techniques and following wetting and drying paths were determined. The material was the same used to manufacture the disposal cells of the Spanish surface facility of El Cabril. The water retention capacity of mortar is clearly higher than that of concrete when expressed as gravimetric water content, but the difference reduces when it is expressed as degree of saturation. Hysteresis between wetting and drying was observed for both materials, particularly for mortar. The tests went on for very long periods of time, and concerns about the geochemical, mineralogical and porosity changes occurred in the materials during the determinations (changes in dry mass, grain density, samples volume) and their repercussion on the results obtained (water content and degree of saturation computation) were raised. Also, the fact of having used techniques applying total and matrix suction could have affected the results. (authors)

  16. Quantitative assessment of angiogenesis in the chick embryo and its chorioallantoic membrane by computerised analysis of angiographic images

    International Nuclear Information System (INIS)

    Nikiforidis, G.; Papazafiropoulos, D.; Siablis, D.; Karnabatidis, D.; Hatjikondi, O.; Dimopoulos, J.

    1999-01-01

    We studied, in vivo, the angiogenesis process in the chick embryo and its chorioallantoic membrane (CAM) using digital subtraction angiography (DSA) in conjunction with computer-assisted image analysis. In a series of fertilised eggs, angiography was carried out at days 8, 10, 12 and 14 of embryonic development. The angiographic images were digitised and subsequently processed for a specific image analysis. A set of specific morphological parameters has been defined to allow an analytical characterisation of the vascularity status. Vessels were classified into three categories according to their diameter (50-100, 100-200, and >200 μm). The data were normalised and statistically evaluated. Graphs showing the development of angiogenesis were obtained. Total vascular area revealed a continuous rise, whereas, total vascular length increased until day 12 and then it started decreasing. These morphometric parameters in the first two vessel categories progressively increased throughout the entire period of development, whereas in the third category they increased until day 10 and then they started decreasing. By applying a vascular casting technique CAM vessels were visualised and compared with those extracted from the processed angiographic image. The comparison revealed that there is exact matching for the first two vessel categories (diameters higher than 100 μm) while the matching of the third category (diameters between 50 and 100 μm) is approximate

  17. Three gradients and the perception of flat and curved surfaces.

    Science.gov (United States)

    Cutting, J E; Millard, R T

    1984-06-01

    Researchers of visual perception have long been interested in the perceived slant of a surface and in the gradients that purportedly specify it. Slant is the angle between the line of sight and the tangent to the planar surface at any point, also called the surface normal. Gradients are the sources of information that grade, or change, with visual angle as one looks from one's feet upward to the horizon. The present article explores three gradients--perspective, compression, and density--and the phenomenal impression of flat and curved surfaces. The perspective gradient is measured at right angles to the axis of tilt at any point in the optic array; that is, when looking down a hallway at the tiles of a floor receding in the distance, perspective is measured by the x-axis width of each tile projected on the image plane orthogonal to the line of sight. The compression gradient is the ratio of y/x axis measures on the projected plane. The density gradient is measured by the number of tiles per unit solid visual angle. For flat surfaces and many others, perspective and compression gradients decrease with distance, and the density gradient increases. We discuss the manner in which these gradients change for various types of surfaces. Each gradient is founded on a different assumption about textures on the surfaces around us. In Experiment 1, viewers assessed the three-dimensional character of projections of flat and curved surfaces receding in the distance. They made pairwise judgments of preference and of dissimilarity among eight stimuli in each of four sets. The presence of each gradient was manipulated orthogonally such that each stimulus had zero, one, two, or three gradients appropriate for either a flat surface or a curved surface. Judgments were made were made for surfaces with both regularly shaped and irregularly shaped textures scattered on them. All viewer assessment were then scaled in one dimension. Multiple correlation and regression on the scale values

  18. Development of the curve of Spee.

    Science.gov (United States)

    Marshall, Steven D; Caspersen, Matthew; Hardinger, Rachel R; Franciscus, Robert G; Aquilino, Steven A; Southard, Thomas E

    2008-09-01

    Ferdinand Graf von Spee is credited with characterizing human occlusal curvature viewed in the sagittal plane. This naturally occurring phenomenon has clinical importance in orthodontics and restorative dentistry, yet we have little understanding of when, how, or why it develops. The purpose of this study was to expand our understanding by examining the development of the curve of Spee longitudinally in a sample of untreated subjects with normal occlusion from the deciduous dentition to adulthood. Records of 16 male and 17 female subjects from the Iowa Facial Growth Study were selected and examined. The depth of the curve of Spee was measured on their study models at 7 time points from ages 4 (deciduous dentition) to 26 (adult dentition) years. The Wilcoxon signed rank test was used to compare changes in the curve of Spee depth between time points. For each subject, the relative eruption of the mandibular teeth was measured from corresponding cephalometric radiographs, and its contribution to the developing curve of Spee was ascertained. In the deciduous dentition, the curve of Spee is minimal. At mean ages of 4.05 and 5.27 years, the average curve of Spee depths are 0.24 and 0.25 mm, respectively. With change to the transitional dentition, corresponding to the eruption of the mandibular permanent first molars and central incisors (mean age, 6.91 years), the curve of Spee depth increases significantly (P < 0.0001) to a mean maximum depth of 1.32 mm. The curve of Spee then remains essentially unchanged until eruption of the second molars (mean age, 12.38 years), when the depth increases (P < 0.0001) to a mean maximum depth of 2.17 mm. In the adolescent dentition (mean age, 16.21 years), the depth decreases slightly (P = 0.0009) to a mean maximum depth of 1.98 mm, and, in the adult dentition (mean age 26.98 years), the curve remains unchanged (P = 0.66), with a mean maximum depth of 2.02 mm. No significant differences in curve of Spee development were found between

  19. CT Angiographic Demonstration of a Mesenteric Vessel 'Whirlpool' in Intestinal Malrotation and Midgut Volvulus: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Bozlar, Ugur; Ugurel, Mehmet Sahin; Ustunsoz, Bahri [Gulhane Military Medical Academy, Ankara (Turkmenistan); Coskun, Unsal [Gulhane Military Medical Academy, Turkish Armed Forces Rehabilitation Center, Ankara (Turkmenistan)

    2008-10-15

    Although the color Doppler ultrasonography diagnosis of intestinal malrotation with midgut volvulus, based on the typical 'whirlpool' appearance of the mesenteric vascular structures is well-defined in the peer-reviewed literature, the combination of both the angiographic illustration of these findings and the contemporary state-of-the-art imaging techniques is lacking. We report the digital subtraction angiography and multidetector computed tomography angiography findings of a 37-year-old male with intestinal malrotation.

  20. Dual kinetic curves in reversible electrochemical systems.

    Directory of Open Access Journals (Sweden)

    Michael J Hankins

    Full Text Available We introduce dual kinetic chronoamperometry, in which reciprocal relations are established between the kinetic curves of electrochemical reactions that start from symmetrical initial conditions. We have performed numerical and experimental studies in which the kinetic curves of the electron-transfer processes are analyzed for a reversible first order reaction. Experimental tests were done with the ferrocyanide/ferricyanide system in which the concentrations of each component could be measured separately using the platinum disk/gold ring electrode. It is shown that the proper ratio of the transient kinetic curves obtained from cathodic and anodic mass transfer limited regions give thermodynamic time invariances related to the reaction quotient of the bulk concentrations. Therefore, thermodynamic time invariances can be observed at any time using the dual kinetic curves for reversible reactions. The technique provides a unique possibility to extract the non-steady state trajectory starting from one initial condition based only on the equilibrium constant and the trajectory which starts from the symmetrical initial condition. The results could impact battery technology by predicting the concentrations and currents of the underlying non-steady state processes in a wide domain from thermodynamic principles and limited kinetic information.