WorldWideScience

Sample records for time slice simulations

  1. Mixed time slicing in path integral simulations

    International Nuclear Information System (INIS)

    Steele, Ryan P.; Zwickl, Jill; Shushkov, Philip; Tully, John C.

    2011-01-01

    A simple and efficient scheme is presented for using different time slices for different degrees of freedom in path integral calculations. This method bridges the gap between full quantization and the standard mixed quantum-classical (MQC) scheme and, therefore, still provides quantum mechanical effects in the less-quantized variables. Underlying the algorithm is the notion that time slices (beads) may be 'collapsed' in a manner that preserves quantization in the less quantum mechanical degrees of freedom. The method is shown to be analogous to multiple-time step integration techniques in classical molecular dynamics. The algorithm and its associated error are demonstrated on model systems containing coupled high- and low-frequency modes; results indicate that convergence of quantum mechanical observables can be achieved with disparate bead numbers in the different modes. Cost estimates indicate that this procedure, much like the MQC method, is most efficient for only a relatively few quantum mechanical degrees of freedom, such as proton transfer. In this regime, however, the cost of a fully quantum mechanical simulation is determined by the quantization of the least quantum mechanical degrees of freedom.

  2. The virtual slice setup.

    Science.gov (United States)

    Lytton, William W; Neymotin, Samuel A; Hines, Michael L

    2008-06-30

    In an effort to design a simulation environment that is more similar to that of neurophysiology, we introduce a virtual slice setup in the NEURON simulator. The virtual slice setup runs continuously and permits parameter changes, including changes to synaptic weights and time course and to intrinsic cell properties. The virtual slice setup permits shocks to be applied at chosen locations and activity to be sampled intra- or extracellularly from chosen locations. By default, a summed population display is shown during a run to indicate the level of activity and no states are saved. Simulations can run for hours of model time, therefore it is not practical to save all of the state variables. These, in any case, are primarily of interest at discrete times when experiments are being run: the simulation can be stopped momentarily at such times to save activity patterns. The virtual slice setup maintains an automated notebook showing shocks and parameter changes as well as user comments. We demonstrate how interaction with a continuously running simulation encourages experimental prototyping and can suggest additional dynamical features such as ligand wash-in and wash-out-alternatives to typical instantaneous parameter change. The virtual slice setup currently uses event-driven cells and runs at approximately 2 min/h on a laptop.

  3. Time efficient whole-brain coverage with MR Fingerprinting using slice-interleaved echo-planar-imaging.

    Science.gov (United States)

    Rieger, Benedikt; Akçakaya, Mehmet; Pariente, José C; Llufriu, Sara; Martinez-Heras, Eloy; Weingärtner, Sebastian; Schad, Lothar R

    2018-04-27

    Magnetic resonance fingerprinting (MRF) is a promising method for fast simultaneous quantification of multiple tissue parameters. The objective of this study is to improve the coverage of MRF based on echo-planar imaging (MRF-EPI) by using a slice-interleaved acquisition scheme. For this, the MRF-EPI is modified to acquire several slices in a randomized interleaved manner, increasing the effective repetition time of the spoiled gradient echo readout acquisition in each slice. Per-slice matching of the signal-trace to a precomputed dictionary allows the generation of T 1 and T 2 * maps with integrated B 1 + correction. Subsequent compensation for the coil sensitivity profile and normalization to the cerebrospinal fluid additionally allows for quantitative proton density (PD) mapping. Numerical simulations are performed to optimize the number of interleaved slices. Quantification accuracy is validated in phantom scans and feasibility is demonstrated in-vivo. Numerical simulations suggest the acquisition of four slices as a trade-off between quantification precision and scan-time. Phantom results indicate good agreement with reference measurements (Difference T 1 : -2.4 ± 1.1%, T 2 *: -0.5 ± 2.5%, PD: -0.5 ± 7.2%). In-vivo whole-brain coverage of T 1 , T 2 * and PD with 32 slices was acquired within 3:36 minutes, resulting in parameter maps of high visual quality and comparable performance with single-slice MRF-EPI at 4-fold scan-time reduction.

  4. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction.

    Science.gov (United States)

    den Harder, J Chiel; van Yperen, Gert H; Blume, Ulrike A; Bos, Clemens

    2015-01-01

    Multispectral imaging (MSI) significantly reduces metal artifacts. Yet, especially in techniques that use gradient selection, such as slice encoding for metal artifact correction (SEMAC), a residual ripple artifact may be prominent. Here, an analysis is presented of the ripple artifact and of slice overlap as an approach to reduce the artifact. The ripple artifact was analyzed theoretically to clarify its cause. Slice overlap, conceptually similar to spectral bin overlap in multi-acquisition with variable resonances image combination (MAVRIC), was achieved by reducing the selection gradient and, thus, increasing the slice profile width. Time domain simulations and phantom experiments were performed to validate the analyses and proposed solution. Discontinuities between slices are aggravated by signal displacement in the frequency encoding direction in areas with deviating B0. Specifically, it was demonstrated that ripple artifacts appear only where B0 varies both in-plane and through-plane. Simulations and phantom studies of metal implants confirmed the efficacy of slice overlap to reduce the artifact. The ripple artifact is an important limitation of gradient selection based MSI techniques, and can be understood using the presented simulations. At a scan-time penalty, slice overlap effectively addressed the artifact, thereby improving image quality near metal implants. © 2014 Wiley Periodicals, Inc.

  5. Outline and handling manual of experimental data time slice monitoring software 'SLICE'

    International Nuclear Information System (INIS)

    Shirai, Hiroshi; Hirayama, Toshio; Shimizu, Katsuhiro; Tani, Keiji; Azumi, Masafumi; Hirai, Ken-ichiro; Konno, Satoshi; Takase, Keizou.

    1993-02-01

    We have developed a software 'SLICE' which maps various kinds of plasma experimental data measured at the different geometrical position of JT-60U and JFT-2M onto the equilibrium magnetic configuration and treats them as a function of volume averaged minor radius ρ. Experimental data can be handled uniformly by using 'SLICE'. Plenty of commands of 'SLICE' make it easy to process the mapped data. The experimental data measured as line integrated values are also transformed by Abel inversion. The mapped data are fitted to a functional form and saved to the database 'MAPDB'. 'SLICE' can read the data from 'MAPDB' and re-display and transform them. Still more 'SLICE' creates run data of orbit following Monte-Carlo code 'OFMC' and tokamak predictive and interpretation code system 'TOPICS'. This report summarizes an outline and the usage of 'SLICE'. (author)

  6. RF slice profile effects in magnetic resonance fingerprinting.

    Science.gov (United States)

    Hong, Taehwa; Han, Dongyeob; Kim, Min-Oh; Kim, Dong-Hyun

    2017-09-01

    The radio frequency (RF) slice profile effects on T1 and T2 estimation in magnetic resonance fingerprinting (MRF) are investigated with respect to time-bandwidth product (TBW), flip angle (FA) level and field inhomogeneities. Signal evolutions are generated incorporating the non-ideal slice selective excitation process using Bloch simulation and matched to the original dictionary with and without the non-ideal slice profile taken into account. For validation, phantom and in vivo experiments are performed at 3T. Both simulations and experiments results show that T1 and T2 error from non-ideal slice profile increases with increasing FA level, off-resonance, and low TBW values. Therefore, RF slice profile effects should be compensated for accurate determination of the MR parameters. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Improving the time efficiency of the Fourier synthesis method for slice selection in magnetic resonance imaging.

    Science.gov (United States)

    Tahayori, B; Khaneja, N; Johnston, L A; Farrell, P M; Mareels, I M Y

    2016-01-01

    The design of slice selective pulses for magnetic resonance imaging can be cast as an optimal control problem. The Fourier synthesis method is an existing approach to solve these optimal control problems. In this method the gradient field as well as the excitation field are switched rapidly and their amplitudes are calculated based on a Fourier series expansion. Here, we provide a novel insight into the Fourier synthesis method via representing the Bloch equation in spherical coordinates. Based on the spherical Bloch equation, we propose an alternative sequence of pulses that can be used for slice selection which is more time efficient compared to the original method. Simulation results demonstrate that while the performance of both methods is approximately the same, the required time for the proposed sequence of pulses is half of the original sequence of pulses. Furthermore, the slice selectivity of both sequences of pulses changes with radio frequency field inhomogeneities in a similar way. We also introduce a measure, referred to as gradient complexity, to compare the performance of both sequences of pulses. This measure indicates that for a desired level of uniformity in the excited slice, the gradient complexity for the proposed sequence of pulses is less than the original sequence. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Real-time slicing algorithm for Stereolithography (STL) CAD model applied in additive manufacturing industry

    Science.gov (United States)

    Adnan, F. A.; Romlay, F. R. M.; Shafiq, M.

    2018-04-01

    Owing to the advent of the industrial revolution 4.0, the need for further evaluating processes applied in the additive manufacturing application particularly the computational process for slicing is non-trivial. This paper evaluates a real-time slicing algorithm for slicing an STL formatted computer-aided design (CAD). A line-plane intersection equation was applied to perform the slicing procedure at any given height. The application of this algorithm has found to provide a better computational time regardless the number of facet in the STL model. The performance of this algorithm is evaluated by comparing the results of the computational time for different geometry.

  9. Time-space modal logic for verification of bit-slice circuits

    Science.gov (United States)

    Hiraishi, Hiromi

    1996-03-01

    The major goal of this paper is to propose a new modal logic aiming at formal verification of bit-slice circuits. The new logic is called as time-space modal logic and its major feature is that it can handle two transition relations: one for time transition and the other for space transition. As for a verification algorithm, a symbolic model checking algorithm of the new logic is shown. This could be applicable to verification of bit-slice microprocessor of infinite bit width and 1D systolic array of infinite length. A simple benchmark result shows the effectiveness of the proposed approach.

  10. Equilibrium initial data for moving puncture simulations: the stationary 1 + log slicing

    International Nuclear Information System (INIS)

    Baumgarte, T W; Matera, K; Etienne, Z B; Liu, Y T; Shapiro, S L; Taniguchi, K; Murchadha, N O

    2009-01-01

    We discuss a 'stationary 1 + log' slicing condition for the construction of solutions to Einstein's constraint equations. For stationary spacetimes, these initial data give a stationary foliation when evolved with 'moving puncture' gauge conditions that are often used in black hole evolutions. The resulting slicing is time independent and agrees with the slicing generated by being dragged along a timelike Killing vector of the spacetime. When these initial data are evolved with moving puncture gauge conditions, numerical errors arising from coordinate evolution should be minimized. While these properties appear very promising, suggesting that this slicing condition should be an attractive alternative to, for example, maximal slicing, we demonstrate in this paper that solutions can be constructed only for a small class of problems. For binary black hole initial data, in particular, it is often assumed that there exists an approximate helical Killing vector that generates the binary's orbit. We show that 1 + log slices that are stationary with respect to such a helical Killing vector cannot be asymptotically flat, unless the spacetime possesses an additional axial Killing vector.

  11. [Simulation and data analysis of stereological modeling based on virtual slices].

    Science.gov (United States)

    Wang, Hao; Shen, Hong; Bai, Xiao-yan

    2008-05-01

    To establish a computer-assisted stereological model for simulating the process of slice section and evaluate the relationship between section surface and estimated three-dimensional structure. The model was designed by mathematic method as a win32 software based on the MFC using Microsoft visual studio as IDE for simulating the infinite process of sections and analysis of the data derived from the model. The linearity of the fitting of the model was evaluated by comparison with the traditional formula. The win32 software based on this algorithm allowed random sectioning of the particles distributed randomly in an ideal virtual cube. The stereological parameters showed very high throughput (>94.5% and 92%) in homogeneity and independence tests. The data of density, shape and size of the section were tested to conform to normal distribution. The output of the model and that from the image analysis system showed statistical correlation and consistency. The algorithm we described can be used for evaluating the stereologic parameters of the structure of tissue slices.

  12. Free-breathing cardiac MR stress perfusion with real-time slice tracking.

    Science.gov (United States)

    Basha, Tamer A; Roujol, Sébastien; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza

    2014-09-01

    To develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise. We propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence. The proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy. The proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans. Copyright © 2013 Wiley Periodicals, Inc.

  13. Time-slicing subsystem of the biology small-angle x-ray scattering station at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Stubblefield, F.W.

    1985-11-01

    The time-slicing subsystem of the Biology Small-Angle X-ray Scattering divides the time period during which the data for small-angle x-ray diffraction patterns from biological samples is collected into time slices (or frames). The subsystem, being part of a multiprocessor experiment control and data acquisition system, has its own dedicated processor; it also has special-purpose front-end electronics sufficient to generate the gating and other control signals required to produce a sequence of as many as 256 time slices, measured with a basic time unit of 1 μsec. The electronics also synchronizes with execution of the time slice sequence the application of stimuli to the biological sample, the measurement of voltages generated by the sample, and the application of auxiliary device trigger pulses and routes detector data and auxiliary scaler data into appropriate time-slice-indexed buffers in a large external data memory array. The structure of the entire experiment control and data acquisition system is briefly reviewed. Details of the structure and operation of the time slice subsystem are presented. 7 refs., 5 figs

  14. Concept and development of measurement method of time sensitivity profile (TSP) in X-ray CT. Comparison of non-helical, single-slice helical, and multi-slice helical scans

    International Nuclear Information System (INIS)

    Tsujioka, Katsumi; Ida, Yoshihiro; Ohtsubo, Hironori; Takahashi, Yasukata; Niwa, Masayoshi

    2000-01-01

    We focused on the time element contained in a single CT image, and devised the concept of a time-sensitivity profile (TSP) describing how the time element is translated into an image. We calculated the data collection time range when the helical pitch is changed in non helical scans, single slice helical scans, and multi slice helical scans. We then calculated the time sensitivity profile (TSP) from the weighting applied when the data collection time range is translated into an image. TSP was also measured for each scanning method using our self-made moving phantom. TSPs obtained from the calculation and the experiments were very close. TSP showed interesting characteristics with each scanning method, especially in the case of multi slice helical scanning, in which TSP became shorter as helical pitch increased. We referred to the TSP's FWHM as the effective scanning time. When we conducted multi slice helical scanning at helical pitch 3, the effective scanning time increased to about 24% longer than that of a non helical scan. When we conducted multi slice helical scanning at helical pitch 5 or 6, the effective scanning time was about half that of a non helical scan. The time sensitivity profile (TSP) is a totally new concept that we consider an important element in discussing the time resolution of a CT scanner. The results of this review will provide significant data in determining the scanning parameters when scanning a moving object. (author)

  15. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-03-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  16. The topology of large-scale structure. VI - Slices of the universe

    Science.gov (United States)

    Park, Changbom; Gott, J. R., III; Melott, Adrian L.; Karachentsev, I. D.

    1992-01-01

    Results of an investigation of the topology of large-scale structure in two observed slices of the universe are presented. Both slices pass through the Coma cluster and their depths are 100 and 230/h Mpc. The present topology study shows that the largest void in the CfA slice is divided into two smaller voids by a statistically significant line of galaxies. The topology of toy models like the white noise and bubble models is shown to be inconsistent with that of the observed slices. A large N-body simulation was made of the biased cloud dark matter model and the slices are simulated by matching them in selection functions and boundary conditions. The genus curves for these simulated slices are spongelike and have a small shift in the direction of a meatball topology like those of observed slices.

  17. Study of imaging time shortening in Whole Heart MRCA. Evaluation of slice thickness

    International Nuclear Information System (INIS)

    Iwai, Mitsuhiro; Tateishi, Toshiki; Takeda, Soji; Hayashi, Ryuji

    2005-01-01

    A series of examinations in cardiac MR imaging, such as cine, perfusion, MR coronary angiography (MRCA) and viability, is generally known as One Stop Cardiac Examination. It takes about 40 to 60 minutes to perform One Stop Cardiac Examination, and Whole Heart MRCA accounts for most of the examination time. Therefore, we aimed to shorten imaging time of Whole Heart MRCA, especially in a large imaging area such as that in the case of the postoperative evaluation of a bypass graft, by investigating the depiction of a diameter of mimic blood vessels as changing the slice thickness of Whole Heart MRCA. The results showed that the maximum slice thickness of about 1 mm was excellent considering the diameters of actual coronary arteries are about 3 mm. In this study, we could grasp the relationships among slice thickness of Whole Heart MRCA, the diameter of a blood vessel, and shortened examination time. We suggested that it was useful for selecting the suitable sequence depending on a patient's conditions. (author)

  18. Numerical simulation of potato slices drying using a two-dimensional finite element model

    Directory of Open Access Journals (Sweden)

    Beigi Mohsen

    2017-01-01

    Full Text Available An experimental and numerical study was conducted to investigate the process of potato slices drying. For simulating the moisture transfer in the samples and predict the dehydration curves, a two-dimensional finite element model was developed and programmed in Compaq Visual Fortran, version 6.5. The model solved the Fick’s second law for slab in a shrinkage system to calculate the unsteady two-dimensional moisture transmission in rectangular coordinates (x,y. Moisture diffusivity and moisture transfer coefficient were determined by minimizing the sum squares of residuals between experimental and numerical predicted data. Shrinkage kinetics of the potato slices during dehydration was determined experimentally and found to be a linear function of removed moisture. The determined parameters were used in the mathematical model. The predicted moisture content values were compared to the experimental data and the validation results demonstrated that the dynamic drying curves were predicted by the methodology very well.

  19. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  20. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi [Hiroshima Univ. (Japan). Hospital] (and others)

    2002-12-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  1. Usefulness of simulation with multi-slice CT for laparoscopic nephrectomy

    International Nuclear Information System (INIS)

    Akiyama, Yuji; Ishifuro, Minoru; Ookubo, Masaomi

    2002-01-01

    In recent years, laparoscopic surgery has attracted attention as a minimally invasive type of surgery because of the small surgical wounds and early recovery it provides. We carry out this technique on the basis of volume data that we make use of in multi-slice CT imaging technology in laparoscopic nephrectomy by the retroperitoneal approach, and we have created CT virtual laparoscopy by virtual endoscopic display as an intra-operative navigator with an image analysis system. We provide information on detailed vascular anatomy to form intra-operative images that act as similar support images. With the provision of this volume data, we consider virtual endoscopic display the most suitable method for surgery. When we perform virtual laparoscopy, we simulate the insertion point and angle, the order of vascular structures and their locations, the number of arteries and veins, and their bifurcation points and ligation points in conjunction with the surgeon prior to operation. As the branch patterns of the renal artery are varied, perioperative confusion and surgical mishaps can be avoided through the information that is provided beforehand. Thus surgery is more accurate and proceeds more smoothly, because the surgeon has accurate anatomical information. In addition, the time required for surgery is decreased, reducing risk and the possibility of complications. (author)

  2. Comparison of sliced lungs with whole lung sets for a torso phantom measured with Ge detectors using Monte Carlo simulations (MCNP).

    Science.gov (United States)

    Kramer, Gary H; Guerriere, Steven

    2003-02-01

    Lung counters are generally used to measure low energy photons (<100 keV). They are usually calibrated with lung sets that are manufactured from a lung tissue substitute material that contains homogeneously distributed activity; however, it is difficult to verify either the activity in the phantom or the homogeneity of the activity distribution without destructive testing. Lung sets can have activities that are as much as 25% different from the expected value. An alternative method to using whole lungs to calibrate a lung counter is to use a sliced lung with planar inserts. Experimental work has already indicated that this alternative method of calibration can be a satisfactory substitute. This work has extended the experimental study by the use of Monte Carlo simulation to validate that sliced and whole lungs are equivalent. It also has determined the optimum slice thicknesses that separate the planar sources in the sliced lung. Slice thicknesses have been investigated in the range of 0.5 cm to 9.0 cm and at photon energies from 17 keV to 1,000 keV. Results have shown that there is little difference between sliced and whole lungs at low energies providing that the slice thickness is 2.0 cm or less. As the photon energy rises the slice thickness can increase substantially with no degradation on equivalence.

  3. The time slice system

    International Nuclear Information System (INIS)

    DeWitt, J.

    1990-01-01

    We have designed a fast readout system for silicon microstrip detectors which could be used at HERA, LHC, and SSC. The system consists of an analog amplifier-comparator chip (AACC) and a digital time slice chip (DTSC). The analog ship is designed in dielectric isolated bipolar technology for low noise and potential radiation hardness. The DTSC is built in CMOS for low power use and high circuit density. The main implementation aims are low power consumption and compactness. The architectural goal is automatic data reduction, and ease of external interface. The pipelining of event information is done digitally in the DTSC. It has a 64 word deep level 1 buffer acting as a FIFO, and a 16 word deep level 2 buffer acting as a dequeue. The DTSC also includes an asynchronous bus interface. We are first building a scaled up (100 μm instead of 25 μm pitch) and slower (10 MHz instead of 60 MHz) version in 2 μm CMOS and plan to test the principle of operation of this system in the Leading Proton Spectrometer (LPS) of the ZEUS detector at HERA. Another very important development will be tested there: the radiation hardening of the chips. We have started a collaboration with a rad-hard foundry and with Los Alamos National Laboratories to test and evaluate rad-hard processes and the final rad-hard product. Initial data are very promising, because radiation resistance of up to many Mrad have been achieved. (orig.)

  4. Drying kinetics of whole and sliced turmeric rhizomes (Curcuma longa L. in a solar conduction dryer

    Directory of Open Access Journals (Sweden)

    A. Borah

    2015-09-01

    Full Text Available Drying of turmeric was carried out in a solar conduction dryer (SCD. Drying air temperature was achieved around 39–51 °C for an ambient temperature in the range of 25–28 °C. Moisture content from 78.65% (wb, was reduced to 6.36% (wb and 5.50% (wb for solid and sliced samples respectively in 12 h effective drying time. Drying curve of sliced samples showed more uniform falling in comparison to that of whole samples. The average effective moisture diffusivity was found to be 1.852 × 10−10 m2 s−1 for slab samples and 1.456 × 10−10 m2 s−1 for solid samples. Out of four models tried for simulation, Page model was found as best fitted thin layer drying model when simulation was done for all the drying data. The overall thermal efficiency of the dryer was found to be 55%. Drying of sliced rhizomes showed better drying kinetics and effective drying time could be reduced by slicing instead of drying in whole form.

  5. High-resolution multi-slice PET

    International Nuclear Information System (INIS)

    Yasillo, N.J.; Chintu Chen; Ordonez, C.E.; Kapp, O.H.; Sosnowski, J.; Beck, R.N.

    1992-01-01

    This report evaluates the progress to test the feasibility and to initiate the design of a high resolution multi-slice PET system. The following specific areas were evaluated: detector development and testing; electronics configuration and design; mechanical design; and system simulation. The design and construction of a multiple-slice, high-resolution positron tomograph will provide substantial improvements in the accuracy and reproducibility of measurements of the distribution of activity concentrations in the brain. The range of functional brain research and our understanding of local brain function will be greatly extended when the development of this instrumentation is completed

  6. Preservation of low slice emittance in bunch compressors

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-03-01

    Full Text Available Minimizing the dilution of the electron beam emittance is crucial for the performance of accelerators, in particular for free electron laser facilities, where the length of the machine and the efficiency of the lasing process depend on it. Measurements performed at the SwissFEL Injector Test Facility revealed an increase in slice emittance after compressing the bunch even for moderate compression factors. The phenomenon was experimentally studied by characterizing the dependence of the effect on beam and machine parameters relevant for the bunch compression. The reproduction of these measurements in simulation required the use of a 3D beam dynamics model along the bunch compressor that includes coherent synchrotron radiation. Our investigations identified transverse effects, such as coherent synchrotron radiation and transverse space charge as the sources of the observed emittance dilution, excluding other effects, such as chromatic effects on single slices or spurious dispersion. We also present studies, both experimental and simulation based, on the effect of the optics mismatch of the slices on the variation of the slice emittance along the bunch. After a corresponding reoptimization of the beam optics in the test facility we reached slice emittances below 200 nm for the central slices along the longitudinal dimension with a moderate increase up to 300 nm in the head and tail for a compression factor of 7.5 and a bunch charge of 200 pC, equivalent to a final current of 150 A, at about 230 MeV energy.

  7. Comparison of 640-Slice Multidetector Computed Tomography Versus 32-Slice MDCT for Imaging of the Osteo-odonto-keratoprosthesis Lamina.

    Science.gov (United States)

    Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C

    2015-08-01

    To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.

  8. NMR surprizes with thin slices and strong gradients

    Energy Technology Data Exchange (ETDEWEB)

    Gaedke, Achim; Kresse, Benjamin [Institute of Condensed Matter Physics, Technische Universitaet Darmstadt (Germany); Nestle, Nikolaus

    2008-07-01

    In the context of our work on diffusion-relaxation-coupling in thin excited slices, we perform NMR experiments in static magnetic field gradients up to 200 T/m. For slice thicknesses in the range of 10{mu}m, the frequency bandwidth of the excited slices becomes sufficiently narrow that free induction decays (FIDs) become observable despite the presence of the strong static gradient. The observed FIDs were also simulated using standard methods from MRI physics. Possible effects of diffusion during the FID duration are still minor at this slice thickness in water but might become dominant for smaller slices or more diffusive media. Furthermore, the detailed excitation structure of the RF pulses was studied in profiling experiments over the edge of a plane liquid cell. Side lobe effects to the slices will be discussed along with approaches to control them. The spatial resolution achieved in the profiling experiments furthermore allows the identification of thermal expansion phenomena in the NMR magnet. Measures to reduce the temperature drift problems are presented.

  9. Timing performances and edge effects of detectors worked from 6-in. silicon slices

    International Nuclear Information System (INIS)

    Aiello, S.; Anzalone, A.; Cardella, G.; Cavallaro, Sl.; De Filippo, E.; Di Pietro, A.; Femino, S.; Geraci, M.; Giustolisi, F.; Guazzoni, P.; Iacono Manno, M.; Lanzalone, G.; Lanzano, G.; Lo Nigro, S.; Musumarra, A.; Pagano, A.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Rizzo, F.; Sambataro, S.; Sperduto, M.L.; Sutera, C.; Zetta, L.

    1997-01-01

    Prototypes of new passivated implanted planar silicon detectors, obtained for the first time from 6 in. silicon slices, have been tested. The time and energy resolutions have been studied as a function of the type and energy of the detected particles, in order to test the performances of these detectors for time of flight measurements in the Chimera project. Some problems arising from edge effects observed in double-pad detectors have been solved by using a guard ring. (orig.)

  10. Fluidic system for long-term in vitro culturing and monitoring of organotypic brain slices

    DEFF Research Database (Denmark)

    Bakmand, Tanya; Troels-Smith, Ane R.; Dimaki, Maria

    2015-01-01

    Brain slice preparations cultured in vitro have long been used as a simplified model for studying brain development, electrophysiology, neurodegeneration and neuroprotection. In this paper an open fluidic system developed for improved long term culturing of organotypic brain slices is presented....... The positive effect of continuous flow of growth medium, and thus stability of the glucose concentration and waste removal, is simulated and compared to the effect of stagnant medium that is most often used in tissue culturing. Furthermore, placement of the tissue slices in the developed device was studied...... by numerical simulations in order to optimize the nutrient distribution. The device was tested by culturing transverse hippocampal slices from 7 days old NMRI mice for a duration of 14 days. The slices were inspected visually and the slices cultured in the fluidic system appeared to have preserved...

  11. RETROSPECTIVE DETECTION OF INTERLEAVED SLICE ACQUISITION PARAMETERS FROM FMRI DATA

    Science.gov (United States)

    Parker, David; Rotival, Georges; Laine, Andrew; Razlighi, Qolamreza R.

    2015-01-01

    To minimize slice excitation leakage to adjacent slices, interleaved slice acquisition is nowadays performed regularly in fMRI scanners. In interleaved slice acquisition, the number of slices skipped between two consecutive slice acquisitions is often referred to as the ‘interleave parameter’; the loss of this parameter can be catastrophic for the analysis of fMRI data. In this article we present a method to retrospectively detect the interleave parameter and the axis in which it is applied. Our method relies on the smoothness of the temporal-distance correlation function, which becomes disrupted along the axis on which interleaved slice acquisition is applied. We examined this method on simulated and real data in the presence of fMRI artifacts such as physiological noise, motion, etc. We also examined the reliability of this method in detecting different types of interleave parameters and demonstrated an accuracy of about 94% in more than 1000 real fMRI scans. PMID:26161244

  12. Radiation sterilization and identification of gizzard slices

    International Nuclear Information System (INIS)

    Zhu, S.; Fu, C.; Jiang, W.; Yao, D.; Zhao, K.; Zhang, Y.

    1998-01-01

    An orthogonal test of 4 factors of radiation dose, storage temperature, storage time, and sanitation of cutting places was carried out to optimize the conditions for disinfection of gizzard slices. In the optimized condition, both the sanitary quality and the shelf-life of gizzard slices were improved. To identify irradiated gizzard slices, the sensory change, and the levels of water-soluble nitrogen, amino acid, total volatile basic nitrogen, peroxide value, vitamin C consumption and KMnO 4 consumption were determinated. No significant change was observed except for the color which was light brown on the surface of irradiated slices

  13. Measurement of slice sensitivity profile for a 64-slice spiral CT system

    International Nuclear Information System (INIS)

    Liu Chuanya; Qin Weichang; Wang Wei; Lu Chuanyou

    2006-01-01

    Objective: To measure and evaluate slice sensitivity profile (SSP) and the full width at half-maximum(FWHM) for a 64-slice spiral CT system. Methods: Using the same CT technique and body mode as those used for clinical CT, delta phantom was scanned with Somatom Sensation 64-slice spiral CT. SSPs and FWHM were measured both with reconstruction slice width of 0.6 mm at pitch=0.50, 0.75, 1.00, 1.25, 1.50 and with reconstruction slice width of 0.6, 1.0, 1.5 mm at pitch=1 respectively. Results: For normal slice width of 0. 6 mm, the measured FWHM, i.e. effective slice width, is 0.67, 0.67, 0.66, 0.69, 0.69 mm at different pitch. All the measured FWHM deviate less than 0.1 mm from the nominal slice width. The measured SSPs are symmetrical, bell-shaped curves without far-reaching tails, and show only slight variations as a function of the spiral pitch. When reconstruction slice width increase, relative SSP become wider. Conclusions: The variation of pitch hardly has effect all on SSP, effective slice width, and z-direction spatial resolution for Sensation 64-slice spiral CT system, which is helpful to optimize CT scanning protocol. (authors)

  14. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    International Nuclear Information System (INIS)

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-01

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies

  15. A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    Science.gov (United States)

    Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin

    2018-07-01

    Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere

    Science.gov (United States)

    Nursalim, Rahmat; Widodo, Basuki; Imron, Chairul

    2017-10-01

    Magnetohydrodynamics (MHD) is important study in engineering and industrial fields. By study on MHD, we can reach the fluid flow characteristics that can be used to minimize its negative effect to an object. In decades, MHD has been widely studied in various geometry forms and fluid types. The sliced sphere is a geometry form that has not been investigated. In this paper we study magnetohydrodynamics of unsteady viscous fluid on boundary layer past a sliced sphere. Assumed that the fluid is incompressible, there is no magnetic field, there is no electrical voltage, the sliced sphere is fix and there is no barrier around the object. In this paper we focus on velocity profile at stagnation point (x = 0°). Mathematical model is governed by continuity and momentum equation. It is converted to non-dimensional, stream function, and similarity equation. Solution of the mathematical model is obtained by using Keller-Box numerical method. By giving various of slicing angle and various of magnetic parameter we get the simulation results. The simulation results show that increasing the slicing angle causes the velocity profile be steeper. Also, increasing the value of magnetic parameter causes the velocity profile be steeper. On the large slicing angle there is no significant effect of magnetic parameter to velocity profile, and on the high the value of magnetic parameter there is no significant effect of slicing angle to velocity profile.

  17. Thick Slice and Thin Slice Teaching Evaluations

    Science.gov (United States)

    Tom, Gail; Tong, Stephanie Tom; Hesse, Charles

    2010-01-01

    Student-based teaching evaluations are an integral component to institutions of higher education. Previous work on student-based teaching evaluations suggest that evaluations of instructors based upon "thin slice" 30-s video clips of them in the classroom correlate strongly with their end of the term "thick slice" student evaluations. This study's…

  18. Architectural slicing

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius

    2013-01-01

    Architectural prototyping is a widely used practice, con- cerned with taking architectural decisions through experiments with light- weight implementations. However, many architectural decisions are only taken when systems are already (partially) implemented. This is prob- lematic in the context...... of architectural prototyping since experiments with full systems are complex and expensive and thus architectural learn- ing is hindered. In this paper, we propose a novel technique for harvest- ing architectural prototypes from existing systems, \\architectural slic- ing", based on dynamic program slicing. Given...... a system and a slicing criterion, architectural slicing produces an architectural prototype that contain the elements in the architecture that are dependent on the ele- ments in the slicing criterion. Furthermore, we present an initial design and implementation of an architectural slicer for Java....

  19. Gravitational collapse of charged dust shell and maximal slicing condition

    International Nuclear Information System (INIS)

    Maeda, Keiichi

    1980-01-01

    The maximal slicing condition is a good time coordinate condition qualitatively when pursuing the gravitational collapse by the numerical calculation. The analytic solution of the gravitational collapse under the maximal slicing condition is given in the case of a spherical charged dust shell and the behavior of time slices with this coordinate condition is investigated. It is concluded that under the maximal slicing condition we can pursue the gravitational collapse until the radius of the shell decreases to about 0.7 x (the radius of the event horizon). (author)

  20. 3D seismic data de-noising and reconstruction using Multichannel Time Slice Singular Spectrum Analysis

    Science.gov (United States)

    Rekapalli, Rajesh; Tiwari, R. K.; Sen, Mrinal K.; Vedanti, Nimisha

    2017-05-01

    Noises and data gaps complicate the seismic data processing and subsequently cause difficulties in the geological interpretation. We discuss a recent development and application of the Multi-channel Time Slice Singular Spectrum Analysis (MTSSSA) for 3D seismic data de-noising in time domain. In addition, L1 norm based simultaneous data gap filling of 3D seismic data using MTSSSA also discussed. We discriminated the noises from single individual time slices of 3D volumes by analyzing Eigen triplets of the trajectory matrix. We first tested the efficacy of the method on 3D synthetic seismic data contaminated with noise and then applied to the post stack seismic reflection data acquired from the Sleipner CO2 storage site (pre and post CO2 injection) from Norway. Our analysis suggests that the MTSSSA algorithm is efficient to enhance the S/N for better identification of amplitude anomalies along with simultaneous data gap filling. The bright spots identified in the de-noised data indicate upward migration of CO2 towards the top of the Utsira formation. The reflections identified applying MTSSSA to pre and post injection data correlate well with the geology of the Southern Viking Graben (SVG).

  1. Alterations in the properties of neonatal thalamocortical synapses with time in in vitro slices.

    Directory of Open Access Journals (Sweden)

    Liliana L Luz

    Full Text Available New synapses are constantly being generated and lost in the living brain with only a subset of these being stabilized to form an enduring component of neuronal circuitry. The properties of synaptic transmission have primarily been established in a variety of in vitro neuronal preparations. It is not clear, however, if newly-formed and persistent synapses contribute to the results of these studies consistently throughout the lifespan of these preparations. In neonatal somatosensory, barrel, cortex we have previously hypothesized that a population of thalamocortical synapses displaying unusually slow kinetics represent newly-formed, default-transient synapses. This clear phenotype would provide an ideal tool to investigate if such newly formed synapses consistently contribute to synaptic transmission throughout a normal experimental protocol. We show that the proportion of synapses recorded in vitro displaying slow kinetics decreases with time after brain slice preparation. However, slow synapses persist in vitro in the presence of either minocycline, an inhibitor of microglia-mediated synapse elimination, or the TrkB agonist 7,8-dihydroxyflavone a promoter of synapse formation. These findings show that the observed properties of synaptic transmission may systematically change with time in vitro in a standard brain slice preparation.

  2. Influence of image slice thickness on rectal dose–response relationships following radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Olsson, C; Thor, M; Apte, A; Deasy, J O; Liu, M; Moissenko, V; Petersen, S E; Høyer, M

    2014-01-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose–response relationships. We investigated this for rectal bleeding using dose–volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman–Kutcher–Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose–response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice

  3. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  4. The effects of slice thickness and reconstructive parameters on VR image quality in multi-slice CT

    International Nuclear Information System (INIS)

    Gao Zhenlong; Wang Qiang; Liu Caixia

    2005-01-01

    Objective: To explore the effects of slice thickness, reconstructive thickness and reconstructive interval on VR image quality in multi-slice CT, in order to select the best slice thickness and reconstructive parameters for the imaging. Methods: Multi-slice CT scan was applied on a rubber dinosaur model with different slice thickness. VR images were reconstructed with different reconstructive thickness and reconstructive interval. Five radiologists were invited to evaluate the quality of the images without knowing anything about the parameters. Results: The slice thickness, reconstructive thickness and reconstructive interval did have effects on VR image quality and the effective degree was different. The effective coefficients were V 1 =1413.033, V 2 =563.733, V 3 =390.533, respectively. The parameters interacted with the others (P<0.05). The smaller of those parameters, the better of the image quality. With a small slice thickness and a reconstructive slice equal to slice thickness, the image quality had no obvious difference when the reconstructive interval was 1/2, 1/3, 1/4 of the slice thickness. Conclusion: A relative small scan slice thickness, a reconstructive slice equal to slice thickness and a reconstructive interval 1/2 of the slice thickness should be selected for the best VR image quality. The image quality depends mostly on the slice thickness. (authors)

  5. Time-Sliced Perturbation Theory II: Baryon Acoustic Oscillations and Infrared Resummation

    CERN Document Server

    Blas, Diego; Ivanov, Mikhail M.; Sibiryakov, Sergey

    2016-01-01

    We use time-sliced perturbation theory (TSPT) to give an accurate description of the infrared non-linear effects affecting the baryonic acoustic oscillations (BAO) present in the distribution of matter at very large scales. In TSPT this can be done via a systematic resummation that has a simple diagrammatic representation and does not involve uncontrollable approximations. We discuss the power counting rules and derive explicit expressions for the resummed matter power spectrum up to next-to leading order and the bispectrum at the leading order. The two-point correlation function agrees well with N-body data at BAO scales. The systematic approach also allows to reliably assess the shift of the baryon acoustic peak due to non-linear effects.

  6. Growth potential of Listeria monocytogenes in sliced turkey bresaola packed in modified atmosphere

    Directory of Open Access Journals (Sweden)

    Elena Dalzini

    2014-02-01

    Full Text Available According to EC Regulation No 2073/2005, for food business operators that produce ready-to-eat (RTE product, it is crucial to be able to demonstrate if the product supports the growth of Listeria monocytogenes. The objective of the study was therefore to evaluate the behaviour of L. monocytogenes in sliced RTE turkey bresaola (made by cured turkey breast 4.5% NaCl, 1% sodium lactate, sodium nitrite 150 ppm and flavouring during the shelf life of the product, simulating a contamination during the slicing operation. Considering a shelf life of 90 days, as defined by manufacturer, the packages of sliced bresaola were stored at 5°C for 7 days and at 8°C for the remaining storage time (83 days. L. monocytogenes count decreased during storage test from 1.43/1.98 log cfu/g in the three batches tested to 1.03 log cfu/g in one batch and to undetectable levels in the other two batches. The results show that the investigated product is unable to support the growth of L. monocytogenes.

  7. Influence of image slice thickness on rectal dose-response relationships following radiotherapy of prostate cancer

    Science.gov (United States)

    Olsson, C.; Thor, M.; Liu, M.; Moissenko, V.; Petersen, S. E.; Høyer, M.; Apte, A.; Deasy, J. O.

    2014-07-01

    When pooling retrospective data from different cohorts, slice thicknesses of acquired computed tomography (CT) images used for treatment planning may vary between cohorts. It is, however, not known if varying slice thickness influences derived dose-response relationships. We investigated this for rectal bleeding using dose-volume histograms (DVHs) of the rectum and rectal wall for dose distributions superimposed on images with varying CT slice thicknesses. We used dose and endpoint data from two prostate cancer cohorts treated with three-dimensional conformal radiotherapy to either 74 Gy (N = 159) or 78 Gy (N = 159) at 2 Gy per fraction. The rectum was defined as the whole organ with content, and the morbidity cut-off was Grade ≥2 late rectal bleeding. Rectal walls were defined as 3 mm inner margins added to the rectum. DVHs for simulated slice thicknesses from 3 to 13 mm were compared to DVHs for the originally acquired slice thicknesses at 3 and 5 mm. Volumes, mean, and maximum doses were assessed from the DVHs, and generalized equivalent uniform dose (gEUD) values were calculated. For each organ and each of the simulated slice thicknesses, we performed predictive modeling of late rectal bleeding using the Lyman-Kutcher-Burman (LKB) model. For the most coarse slice thickness, rectal volumes increased (≤18%), whereas maximum and mean doses decreased (≤0.8 and ≤4.2 Gy, respectively). For all a values, the gEUD for the simulated DVHs were ≤1.9 Gy different than the gEUD for the original DVHs. The best-fitting LKB model parameter values with 95% CIs were consistent between all DVHs. In conclusion, we found that the investigated slice thickness variations had minimal impact on rectal dose-response estimations. From the perspective of predictive modeling, our results suggest that variations within 10 mm in slice thickness between cohorts are unlikely to be a limiting factor when pooling multi-institutional rectal dose data that include slice thickness

  8. Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography

    International Nuclear Information System (INIS)

    Hsieh Jiang

    2001-01-01

    Multislice computed tomography (MCT) is one of the recent technology advancements in CT. Compared to single slice CT, MCT significantly improves examination time, x-ray tube efficiency, and contrast material utilization. Although the scan mode of MCT is predominately helical, step-and-shoot (axial) scans continue to be an important part of routine clinical protocols. In this paper, we present a detailed investigation on the slice sensitivity profile (SSP) of MCT in the step-and-shoot mode. Our investigation shows that, unlike single slice CT, the SSP for MCT exhibits multiple peaks and valleys resulting from intercell gaps between detector rows. To fully understand the characteristics of the SSP, we developed an analytical model to predict the behavior of MCT. We propose a simple experimental technique that can quickly and accurately measure SSP. The impact of the SSP on image artifacts and low contrast detectability is also investigated

  9. Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method

    International Nuclear Information System (INIS)

    Schumann, Stefan; Burcza, Boris; Guttmann, Josef; Haberthür, Christoph; Lichtwarck-Aschoff, Michael

    2009-01-01

    In the clinical situation and in most research work, the analysis of respiratory system mechanics is limited to the estimation of single-value compliances during static or quasi-static conditions. In contrast, our SLICE method analyses intratidal nonlinearity under the dynamic conditions of mechanical ventilation by calculating compliance and resistance for six conjoined volume portions (slices) of the pressure–volume loop by multiple linear regression analysis. With the gliding-SLICE method we present a new approach to determine continuous intratidal nonlinear compliance. The performance of the gliding-SLICE method was tested both in computer simulations and in a physical model of the lung, both simulating different intratidal compliance profiles. Compared to the original SLICE method, the gliding-SLICE method resulted in smaller errors when calculating the compliance or pressure course (all p 2 O s L −1 to 0.8 ± 0.3 cmH 2 O s L −1 (mathematical model) and from 7.2 ± 3.9 cmH 2 O s L −1 to 0.4 ± 0.2 cmH 2 O s L −1 (physical model) (all p < 0.001). We conclude that the new gliding-SLICE method allows detailed assessment of intratidal nonlinear respiratory system mechanics without discontinuity error

  10. Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation

    Science.gov (United States)

    Kim, Kio; Habas, Piotr A.; Rousseau, Francois; Glenn, Orit A.; Barkovich, Anthony J.; Studholme, Colin

    2012-01-01

    In recent years post-processing of fast multi-slice MR imaging to correct fetal motion has provided the first true 3D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two step iterative process, where slices from the acquired data are re-aligned to an approximate 3D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3D reconstruction, and is limited in its ability to recover sub-voxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3D reconstructions containing clinically useful additional information not visible in the original 2D slices. PMID:19744911

  11. Improved biochemical preservation of lung slices during cold storage.

    Science.gov (United States)

    Bull, D A; Connors, R C; Reid, B B; Albanil, A; Stringham, J C; Karwande, S V

    2000-05-15

    Development of lung preservation solutions typically requires whole-organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that lung slices could be used to assess preservation of biochemical function during cold storage. Whole rat lungs were precision cut into slices with a thickness of 500 microm and preserved at 4 degrees C in the following solutions: University of Wisconsin (UW), Euro-Collins (EC), low-potassium-dextran (LPD), Kyoto (K), normal saline (NS), or a novel lung preservation solution (NPS) developed using this model. Lung biochemical function was assessed by ATP content (etamol ATP/mg wet wt) and capacity for protein synthesis (cpm/mg protein) immediately following slicing (0 h) and at 6, 12, 18, and 24 h of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as means +/- SD. ATP content was significantly higher in the lung slices stored in NPS compared with all other solutions at each time point (P cold storage. Copyright 2000 Academic Press.

  12. Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time

    International Nuclear Information System (INIS)

    Wink, Nicole M; McNitt-Gray, Michael F; Solberg, Timothy D

    2005-01-01

    While respiration-correlated CT is gaining acceptance in clinical radiotherapy, the effect of scanning parameters on the image quality has yet to be addressed. The intent of this study was to characterize the effects of gantry rotation and table speed on various image quality characteristics in multi-slice, helical, retrospectively-gated CT images. Images of stationary and moving phantoms were obtained in helical mode on a 20-slice CT scanner. Motion was generated by a computer-controlled platform capable of moving simultaneously in two dimensions. Motion was monitored using a pressure gauge inserted inside an adjustable belt. Selected scans were retrospectively gated into ten phases based on the monitored motion. Gantry rotation speeds of 0.5 s and 1.0 s were evaluated with pitches ranging from 0.1 to 0.45. Several parameters, including calculated object volumes, trajectory (movement from peak to trough), deformation (actual volume divided by volume created with the maximum diameter of contoured object) and z-axis resolution, were used to characterize image quality. These studies indicate that for objects in the peak phase of a movement pattern that simulates breathing, retrospectively gated scans using fast gantry rotation speeds produce volume, trajectory, deformation and z-axis resolution results comparable with those of a stationary object

  13. Feasibility study of 2D thick-slice MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Takeuchi, Miho; Higashimura, Kyouji; Komuro, Hiroyuki

    2000-01-01

    Conditions required to perform contrast MR digital subtraction angiography using a two-dimensional thick-slice high-speed gradient echo were investigated. The conditions in the phantom experiment included: slice profile, flip angle, imaging matrix, fat suppression, duration of IR pulse and frequency selectivity, flip angle of IR pulse and inversion time. Based on the results of the experiment, 2D thick-slice MRDSA was performed in volunteers. Under TR/TE=5.3-9/1.3-1.8 ms conditions, the requirements were a slice thick enough to include the target region, a flip angle of 10 degrees, and a phase matrix of 96 or more. Fat suppression was required for adipose-tissue-rich regions, such as the abdomen. The optimal conditions for applying the IR preparation pulse of the IR prepped fast gradient recalled echo as spectrally selective inversion recovery appeared to be: duration of IR pulse =20 ms, flip angle =100 degrees, and inversion time =40 ms. The authors concluded that it was feasible to perform 2D thick-slice MRDSA with time resolution within 1 second. (K.H.)

  14. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  15. Improved sliced velocity map imaging apparatus optimized for H photofragments.

    Science.gov (United States)

    Ryazanov, Mikhail; Reisler, Hanna

    2013-04-14

    Time-sliced velocity map imaging (SVMI), a high-resolution method for measuring kinetic energy distributions of products in scattering and photodissociation reactions, is challenging to implement for atomic hydrogen products. We describe an ion optics design aimed at achieving SVMI of H fragments in a broad range of kinetic energies (KE), from a fraction of an electronvolt to a few electronvolts. In order to enable consistently thin slicing for any imaged KE range, an additional electrostatic lens is introduced in the drift region for radial magnification control without affecting temporal stretching of the ion cloud. Time slices of ∼5 ns out of a cloud stretched to ⩾50 ns are used. An accelerator region with variable dimensions (using multiple electrodes) is employed for better optimization of radial and temporal space focusing characteristics at each magnification level. The implemented system was successfully tested by recording images of H fragments from the photodissociation of HBr, H2S, and the CH2OH radical, with kinetic energies ranging from 3 eV. It demonstrated KE resolution ≲1%-2%, similar to that obtained in traditional velocity map imaging followed by reconstruction, and to KE resolution achieved previously in SVMI of heavier products. We expect it to perform just as well up to at least 6 eV of kinetic energy. The tests showed that numerical simulations of the electric fields and ion trajectories in the system, used for optimization of the design and operating parameters, provide an accurate and reliable description of all aspects of system performance. This offers the advantage of selecting the best operating conditions in each measurement without the need for additional calibration experiments.

  16. Mis-estimation and bias of hyperpolarized apparent diffusion coefficient measurements due to slice profile effects.

    Science.gov (United States)

    Gordon, Jeremy W; Milshteyn, Eugene; Marco-Rius, Irene; Ohliger, Michael; Vigneron, Daniel B; Larson, Peder E Z

    2017-09-01

    The purpose of this work was to explore the impact of slice profile effects on apparent diffusion coefficient (ADC) mapping of hyperpolarized (HP) substrates. Slice profile effects were simulated using a Gaussian radiofrequency (RF) pulse with a variety of flip angle schedules and b-value ordering schemes. A long T 1 water phantom was used to validate the simulation results, and ADC mapping of HP [ 13 C, 15 N 2 ]urea was performed on the murine liver to assess these effects in vivo. Slice profile effects result in excess signal after repeated RF pulses, causing bias in HP measurements. The largest error occurs for metabolites with small ADCs, resulting in up to 10-fold overestimation for metabolites that are in more-restricted environments. A mixed b-value scheme substantially reduces this bias, whereas scaling the slice-select gradient can mitigate it completely. In vivo, the liver ADC of hyperpolarized [ 13 C, 15 N 2 ]urea is nearly 70% lower (0.99 ± 0.22 vs 1.69 ± 0.21 × 10 -3 mm 2 /s) when slice-select gradient scaling is used. Slice profile effects can lead to bias in HP ADC measurements. A mixed b-value ordering scheme can reduce this bias compared to sequential b-value ordering. Slice-select gradient scaling can also correct for this deviation, minimizing bias and providing more-precise ADC measurements of HP substrates. Magn Reson Med 78:1087-1092, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Portable Device Slices Thermoplastic Prepregs

    Science.gov (United States)

    Taylor, Beverly A.; Boston, Morton W.; Wilson, Maywood L.

    1993-01-01

    Prepreg slitter designed to slit various widths rapidly by use of slicing bar holding several blades, each capable of slicing strip of preset width in single pass. Produces material evenly sliced and does not contain jagged edges. Used for various applications in such batch processes involving composite materials as press molding and autoclaving, and in such continuous processes as pultrusion. Useful to all manufacturers of thermoplastic composites, and in slicing B-staged thermoset composites.

  18. Fresh Slice Self-Seeding and Fresh Slice Harmonic Lasing at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.W. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2018-04-01

    We present results from the successful demonstration of fresh slice self-seeding at the Linac Coherent Light Source (LCLS).* The performance is compared with SASE and regular self-seeding at photon energy of 5.5 keV, resulting in a relative average brightness increase of a factor of 12 and a factor of 2 respectively. Following this proof-of-principle we discuss the forthcoming plans to use the same technique** for fresh slice harmonic lasing in an upcoming experiment. The demonstration of fresh slice harmonic lasing provides an attractive solution for future XFELs aiming to achieve high efficiency, high brightness X-ray pulses at high photon energies (>12 keV).***

  19. Flat slices in Minkowski space

    Science.gov (United States)

    Murchadha, Niall Ó.; Xie, Naqing

    2015-03-01

    Minkowski space, flat spacetime, with a distance measure in natural units of d{{s}2}=-d{{t}2}+d{{x}2}+d{{y}2}+d{{z}2}, or equivalently, with spacetime metric diag(-1, +1, +1, +1), is recognized as a fundamental arena for physics. The Poincaré group, the set of all rigid spacetime rotations and translations, is the symmetry group of Minkowski space. The action of this group preserves the form of the spacetime metric. Each t = constant slice of each preferred coordinate system is flat. We show that there are also nontrivial non-singular representations of Minkowski space with complete flat slices. If the embedding of the flat slices decays appropriately at infinity, the only flat slices are the standard ones. However, if we remove the decay condition, we find non-trivial flat slices with non-vanishing extrinsic curvature. We write out explicitly the coordinate transformation to a frame with such slices.

  20. Effects of Temperature and Slice Thickness on Drying Kinetics of Pumpkin Slices

    OpenAIRE

    Kongdej LIMPAIBOON

    2011-01-01

    Dried pumpkin slice is an alternative crisp food product. In this study, the effects of temperature and slice thickness on the drying characteristics of pumpkin were studied in a lab-scale tray dryer, using hot air temperatures of 55, 60 and 65 °C and 2, 3 and 4 mm slice thickness at a constant air velocity of 1.5 m/s. The initial moisture content of the pumpkin samples was 900.5 % (wb). The drying process was carried out until the final moisture content of product was 100.5 % (wb). The resul...

  1. Intersection-based registration of slice stacks to form 3D images of the human fetal brain

    DEFF Research Database (Denmark)

    Kim, Kio; Hansen, Mads Fogtmann; Habas, Piotr

    2008-01-01

    Clinical fetal MR imaging of the brain commonly makes use of fast 2D acquisitions of multiple sets of approximately orthogonal 2D slices. We and others have previously proposed an iterative slice-to-volume registration process to recover a geometrically consistent 3D image. However......, these approaches depend on a 3D volume reconstruction step during the slice alignment. This is both computationally expensive and makes the convergence of the registration process poorly defined. In this paper our key contribution is a new approach which considers the collective alignment of all slices directly...... of the approach applied to simulated data and clinically acquired fetal images....

  2. Experimental demonstration of spectrum-sliced elastic optical path network (SLICE).

    Science.gov (United States)

    Kozicki, Bartłomiej; Takara, Hidehiko; Tsukishima, Yukio; Yoshimatsu, Toshihide; Yonenaga, Kazushige; Jinno, Masahiko

    2010-10-11

    We describe experimental demonstration of spectrum-sliced elastic optical path network (SLICE) architecture. We employ optical orthogonal frequency-division multiplexing (OFDM) modulation format and bandwidth-variable optical cross-connects (OXC) to generate, transmit and receive optical paths with bandwidths of up to 1 Tb/s. We experimentally demonstrate elastic optical path setup and spectrally-efficient transmission of multiple channels with bit rates ranging from 40 to 140 Gb/s between six nodes of a mesh network. We show dynamic bandwidth scalability for optical paths with bit rates of 40 to 440 Gb/s. Moreover, we demonstrate multihop transmission of a 1 Tb/s optical path over 400 km of standard single-mode fiber (SMF). Finally, we investigate the filtering properties and the required guard band width for spectrally-efficient allocation of optical paths in SLICE.

  3. A comparative risk assessment for Listeria monocytogenes in prepackaged versus retail-sliced deli meat.

    Science.gov (United States)

    Endrikat, Sarah; Gallagher, Daniel; Pouillot, Régis; Hicks Quesenberry, Heather; Labarre, David; Schroeder, Carl M; Kause, Janell

    2010-04-01

    Deli meat was ranked as the highest-risk ready-to-eat food vehicle of Listeria monocytogenes within the 2003 U.S. Food and Drug Administration and U.S. Department of Agriculture, Food Safety and Inspection Service risk assessment. The comparative risk of L. monocytogenes in retail-sliced versus prepackaged deli meats was evaluated with a modified version of this model. Other research has found that retail-sliced deli meats have both higher prevalence and levels of L. monocytogenes than have product sliced and packaged at the manufacturer level. The updated risk assessment model considered slicing location as well as the use of growth inhibitors. The per annum comparative risk ratio for the number of deaths from retail-sliced versus prepackaged deli meats was found to be 4.89, and the per-serving comparative risk ratio was 4.27. There was a significant interaction between the use of growth inhibitors and slicing location. Almost 70% of the estimated deaths occurred from retail-sliced product that did not possess a growth inhibitor. A sensitivity analysis, assessing the effect of the model's consumer storage time and shelf life assumptions, found that even if retail-sliced deli meats were stored for a quarter of the time prepackaged deli meats were stored, retail-sliced product is 1.7 times more likely to result in death from listeriosis. Sensitivity analysis also showed that the shelf life assumption had little effect on the comparative risk ratio.

  4. A kinetic model to simulate the effect of cooking time-temperature on the gastric digestion of meat

    OpenAIRE

    Kondjoyan, Alain; Daudin, Jean-Dominique; Portanguen, Stéphane; Aubry, Laurent; Sante-Lhoutellier, Veronique

    2014-01-01

    A kinetic model was developed to predict the effect of cooking time and temperature on the digestibility of myofibrillar proteins. The predictions were confronted to the measurement of the in vitro digestibility of myofibrillar proteins coming from either slices of beef meat heated in water bath or from a piece of meat roasted in a domestic oven. The model was able to simulate the in vitro measurements for the meat pieces of different sizes cooked under different condi...

  5. Adaptive SLICE method: an enhanced method to determine nonlinear dynamic respiratory system mechanics

    International Nuclear Information System (INIS)

    Zhao, Zhanqi; Möller, Knut; Guttmann, Josef

    2012-01-01

    The objective of this paper is to introduce and evaluate the adaptive SLICE method (ASM) for continuous determination of intratidal nonlinear dynamic compliance and resistance. The tidal volume is subdivided into a series of volume intervals called slices. For each slice, one compliance and one resistance are calculated by applying a least-squares-fit method. The volume window (width) covered by each slice is determined based on the confidence interval of the parameter estimation. The method was compared to the original SLICE method and evaluated using simulation and animal data. The ASM was also challenged with separate analysis of dynamic compliance during inspiration. If the signal-to-noise ratio (SNR) in the respiratory data decreased from +∞ to 10 dB, the relative errors of compliance increased from 0.1% to 22% for the ASM and from 0.2% to 227% for the SLICE method. Fewer differences were found in resistance. When the SNR was larger than 40 dB, the ASM delivered over 40 parameter estimates (42.2 ± 1.3). When analyzing the compliance during inspiration separately, the estimates calculated with the ASM were more stable. The adaptive determination of slice bounds results in consistent and reliable parameter values. Online analysis of nonlinear respiratory mechanics will profit from such an adaptive selection of interval size. (paper)

  6. On the way to isotopic spatial resolution: technical principles and applications of 16-slice CT

    International Nuclear Information System (INIS)

    Flohr, T.; Ohnesorge, B.; Stierstorfer, K.

    2005-01-01

    The broad introduction of multi-slice CT by all major vendors in 1998 was a milestone with regard to extended volume coverage, improved axial resolution and better utilization of the tube output. New clinical applications such as CT-examinations of the heart and the coronary arteries became possible. Despite all promising advances, some limitations remain for 4-slice CT systems. They come close to isotropic resolution, but do not fully reach it in routine clinical applications. Cardiac CT-examinations require careful patient selection. The new generation of multi-slice CT-systems offer simultaneous acquisition of up to 16 sub-millimeter slices and improved temporal resolution for cardiac examinations by means of reduced gantry rotation time (0.4 s). In this overview article we present the basic technical principles and potential applications of 16-slice technology for the example of a 16-slice CT-system (SOMATOM Sensation 16, Siemens AG, Forchheim). We discuss detector design and dose efficiency as well as spiral scan- and reconstruction techniques. At comparable slice thickness, 16-slice CT-systems have a better dose efficiency than 4-slice CT-systems. The cone-beam geometry of the measurement rays requires new reconstruction approaches, an example is the adaptive multiple plane reconstruction, AMPR. First clinical experience indicates that sub-millimeter slice width in combination with reduced gantry rotation-time improves the clinical stability of cardiac examinations and expands the spectrum of patients accessible to cardiac CT. 16-slice CT-systems have the potential to cover even large scan ranges with sub-millimeter slices at considerably reduced examination times, thus approaching the goal of routine isotropic imaging [de

  7. Time-slice analysis of the Australian summer monsoon during the late Quaternary using the Fast Ocean Atmosphere Model

    Science.gov (United States)

    Marshall, A. G.; Lynch, A. H.

    2006-10-01

    We use the Fast Ocean Atmosphere Model (FOAM) to investigate the variation in the Australian summer monsoon over the last 55 000 years. A synthesis of palaeoenvironmental observations is used to constrain the model for six time slices: 55, 35, 21, 11, 6 and 0 ka. Both inter-hemispheric forcing and the seasonal timing of local insolation changes play key, and interacting, roles on the evolution and intensity of the monsoon.During the onset to the monsoon, a heat low develops to the west of Australia over the Indian Ocean in all time slices, but with varying strengths. Divergent outflow from Asia converges with the cyclonic flow to bring increased rainfall to northern Australia and the maritime continent. The relative importance of a low pressure pull and the high pressure push varies according to the strength of the pressure anomalies. Only in the middle Holocene is the low pressure pull the dominant forcing mechanism. At 21 ka, the climate shift to colder mean temperatures determines the large-scale dynamics of the monsoon.The general picture that emerges from these results is consistent with available palaeodata but highlights the importance of a broad regional perspective to ascribe the driving mechanisms at different times. Copyright

  8. Comparison of classic simulation and virtual simulation in breast irradiation: prospective study on 14 patients

    International Nuclear Information System (INIS)

    Bauduceau, O.; Pons, P.; Romero, L.; Fayolle, M.; Campana, F.; Bollet, M.

    2005-01-01

    Purpose. - To compare conventional 2D simulation and virtual simulation on 14 patients with breast cancer. Patients and methods. - Patients were simulated for treatment using standard procedure. They subsequently underwent CT scan in the treatment position. The CTV was defined as breast tissue. The PTV was obtained by adding a 3D margin of 1 cm around CTV. Organs at risk (lungs and heart) were outlined. Ballistics and dose distribution obtained with the two planning methods were compared. Results. - With conventional simulation, 95% of CTV received 95% of the dose prescribed. Virtual simulation significantly improved dosimetric coverage of PTV without increasing irradiation volume of lung and heart. In 2D simulation, using three slices allowed optimisation by adjusting wedge angle. The five-slice plan was a much better predictor of the maximum dose regions when compared to the three-slice plan. Using entire CT data did not give any benefit. Conclusion. - Variations in CTV delineation and PTV definition limit interest of virtual simulation. In classic simulation, a 5 CT slice-plan can be used to optimise dose distribution. (author)

  9. Modelling and experimental validation of thin layer indirect solar drying of mango slices

    Energy Technology Data Exchange (ETDEWEB)

    Dissa, A.O.; Bathiebo, J.; Kam, S.; Koulidiati, J. [Laboratoire de Physique et de Chimie de l' Environnement (LPCE), Unite de Formation et de Recherche en Sciences Exactes et Appliquee (UFR/SEA), Universite de Ouagadougou, Avenue Charles de Gaulle, BP 7021 Kadiogo (Burkina Faso); Savadogo, P.W. [Laboratoire Sol Eau Plante, Institut de l' Environnement et de Recherches Agricoles, 01 BP 476, Ouagadougou (Burkina Faso); Desmorieux, H. [Laboratoire d' Automatisme et de Genie des Procedes (LAGEP), UCBL1-CNRS UMR 5007-CPE Lyon, Bat.308G, 43 bd du 11 Nov. 1918 Villeurbanne, Universite Claude Bernard Lyon1, Lyon (France)

    2009-04-15

    The thin layer solar drying of mango slices of 8 mm thick was simulated and experimented using a solar dryer designed and constructed in laboratory. Under meteorological conditions of harvest period of mangoes, the results showed that 3 'typical days' of drying were necessary to reach the range of preservation water contents. During these 3 days of solar drying, 50%, 40% and 5% of unbound water were eliminated, respectively, at the first, second and the third day. The final water content obtained was about 16 {+-} 1.33% d.b. (13.79% w.b.). This final water content and the corresponding water activity (0.6 {+-} 0.02) were in accordance with previous work. The drying rates with correction for shrinkage and the critical water content were experimentally determined. The critical water content was close to 70% of the initial water content and the drying rates were reduced almost at 6% of their maximum value at night. The thin layer drying model made it possible to simulate suitably the solar drying kinetics of mango slices with a correlation coefficient of r{sup 2} = 0.990. This study thus contributed to the setting of solar drying time of mango and to the establishment of solar drying rates' curves of this fruit. (author)

  10. Constructing a Computer Model of the Human Eye Based on Tissue Slice Images

    OpenAIRE

    Dai, Peishan; Wang, Boliang; Bao, Chunbo; Ju, Ying

    2010-01-01

    Computer simulation of the biomechanical and biological heat transfer in ophthalmology greatly relies on having a reliable computer model of the human eye. This paper proposes a novel method on the construction of a geometric model of the human eye based on tissue slice images. Slice images were obtained from an in vitro Chinese human eye through an embryo specimen processing methods. A level set algorithm was used to extract contour points of eye tissues while a principle component analysi...

  11. A simple method for multiday imaging of slice cultures.

    Science.gov (United States)

    Seidl, Armin H; Rubel, Edwin W

    2010-01-01

    The organotypic slice culture (Stoppini et al. A simple method for organotypic cultures of nervous tissue. 1991;37:173-182) has become the method of choice to answer a variety of questions in neuroscience. For many experiments, however, it would be beneficial to image or manipulate a slice culture repeatedly, for example, over the course of many days. We prepared organotypic slice cultures of the auditory brainstem of P3 and P4 mice and kept them in vitro for up to 4 weeks. Single cells in the auditory brainstem were transfected with plasmids expressing fluorescent proteins by way of electroporation (Haas et al. Single-cell electroporation for gene transfer in vivo. 2001;29:583-591). The culture was then placed in a chamber perfused with oxygenated ACSF and the labeled cell imaged with an inverted wide-field microscope repeatedly for multiple days, recording several time-points per day, before returning the slice to the incubator. We describe a simple method to image a slice culture preparation during the course of multiple days and over many continuous hours, without noticeable damage to the tissue or photobleaching. Our method uses a simple, inexpensive custom-built insulator constructed around the microscope to maintain controlled temperature and uses a perfusion chamber as used for in vitro slice recordings. (c) 2009 Wiley-Liss, Inc.

  12. Induksi Ginogenesis melalui Kultur Multi Ovule Slice dan Kultur Ovary Slice Dianthus chinensis

    Directory of Open Access Journals (Sweden)

    Suskandari Kartikaningrum

    2013-10-01

    Full Text Available Callus induction was studied in five genotypes of Dianthus chinensis using 2.4 D and NAA. Calluses can be obtainedfrom unfertilized ovule culture and ovary culture. The aim of the research was to study gynogenic potential and responseof Dianthus chinensis through ovule slice and ovary slice culture for obtaining haploid plants. Five genotypes of Dianthuschinensis and five media were used in ovule slice culture and two genotypes and three medium were used in ovary culture.Flower buds in the 7th stage were incubated for the purpose of dark pre-treatment at 4 oC for one day. Ovules and ovaries wereisolated and cultured in induction medium. Cultures were incubated for the purpose of dark pre-treatment at 4 oC for seven days, followed by 25 oC light incubation. The result showed that 2.4D was better than NAA in inducing callus. Percentage of regenerated calluses were produced in V11, V13 and V15 genotypes in M7 medium (MS + 2 mg L-1 2.4D + 1 mg L-1 BAP + 30 g L-1 sucrose and M10 medium (MS + 1 mg L-1 2.4D + 1 mg L-1 BAP + 20 g L-1 sucrose. All calluses originated from ovule and ovary cultures flowered prematurely. Double haploid (V11-34 were obtained from ovule slice culture based on PER (peroksidase and EST (esterase isoenzym marker.Keywords: ovule slice culture, ovary slice culture, callus, Dianthus sp., haploid

  13. Dosimetric variation due to CT inter-slice spacing in four-dimensional carbon beam lung therapy

    International Nuclear Information System (INIS)

    Kumagai, Motoki; Mori, Shinichiro; Kandatsu, Susumu; Baba, Masayuki; Sharp, Gregory C; Asakura, Hiroshi; Endo, Masahiro

    2009-01-01

    When CT data with thick slice thickness are used in treatment planning, geometrical uncertainty may induce dosimetric errors. We evaluated carbon ion dose variations due to different CT slice thicknesses using a four-dimensional (4D) carbon ion beam dose calculation, and compared results between ungated and gated respiratory strategies. Seven lung patients were scanned in 4D mode with a 0.5 mm slice thickness using a 256-multi-slice CT scanner. CT images were averaged with various numbers of images to simulate reconstructed images with various slice thicknesses (0.5-5.0 mm). Two scenarios were studied (respiratory-ungated and -gated strategies). Range compensators were designed for each of the CT volumes with coarse inter-slice spacing to cover the internal target volume (ITV), as defined from 4DCT. Carbon ion dose distribution was computed for each resulting ITV on the 0.5 mm slice 4DCT data. The accumulated dose distribution was then calculated using deformable registration for 4D dose assessment. The magnitude of over- and under-dosage was found to be larger with the use of range compensators designed with a coarser inter-slice spacing than those obtained with a 0.5 mm slice thickness. Although no under-dosage was observed within the clinical target volume (CTV) region, D95 remained at over 97% of the prescribed dose for the ungated strategy and 95% for the gated strategy for all slice thicknesses. An inter-slice spacing of less than 3 mm may be able to minimize dose variation between the ungated and gated strategies. Although volumes with increased inter-slice spacing may reduce geometrical accuracy at a certain respiratory phase, this does not significantly affect delivery of the accumulated dose to the target during the treatment course.

  14. Accelerating Magnetic Resonance Fingerprinting (MRF) using t-Blipped Simultaneous Multi-Slice (SMS) acquisition

    Science.gov (United States)

    Ye, Huihui; Ma, Dan; Jiang, Yun; Cauley, Stephen F.; Du, Yiping; Wald, Lawrence L.; Griswold, Mark A.; Setsompop, Kawin

    2015-01-01

    Purpose We incorporate Simultaneous Multi-Slice (SMS) acquisition into MR Fingerprinting (MRF) to accelerate the MRF acquisition. Methods The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the signal from different simultaneously excited slices are encoded with different phases without disturbing the signal evolution. Further, by varying the Gz blip area and/or polarity as a function of TR, the slices’ differential phase can also be made to vary as a function of time. For reconstruction of t-Blipped SMS-MRF data, we demonstrate a combined slice-direction SENSE and modified dictionary matching method. Results In Monte Carlo simulation, the parameter mapping from Multi-band factor (MB)=2 t-Blipped SMS-MRF shows good accuracy and precision when compared to results from reference conventional MRF data with concordance correlation coefficients (CCC) of 0.96 for T1 estimates and 0.90 for T2 estimates. For in vivo experiments, T1 and T2 maps from MB=2 t-Blipped SMS-MRF have a high agreement with ones from conventional MRF. Conclusions The MB=2 t-Blipped SMS-MRF acquisition/reconstruction method has been demonstrated and validated to provide more rapid parameter mapping in the MRF framework. PMID:26059430

  15. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boss, Andreas, E-mail: andreas.boss@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Piccirelli, Marco [Institute of Neuroradiology, University Hospital of Zurich (Switzerland); Reiner, Caecilia S. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland)

    2016-11-15

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  16. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    International Nuclear Information System (INIS)

    Boss, Andreas; Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C.; Piccirelli, Marco; Reiner, Caecilia S.

    2016-01-01

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  17. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    International Nuclear Information System (INIS)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M.; Wagstaff, Anne W.; Smeltzer, Matthew P.; Krafft, Axel J.; Hankins, Jane S.

    2017-01-01

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  18. Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, Ralf B.; McCarville, M.B.; Song, Ruitian; Hillenbrand, Claudia M. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Wagstaff, Anne W. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); Rhodes College, Memphis, TN (United States); University of Alabama at Birmingham School of Medicine, Birmingham, AL (United States); Smeltzer, Matthew P. [St. Jude Children' s Research Hospital, Department of Biostatistics, Memphis, TN (United States); University of Memphis, Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, Memphis, TN (United States); Krafft, Axel J. [St. Jude Children' s Research Hospital, Diagnostic Imaging, Memphis, TN (United States); University Hospital Center Freiburg, Department of Radiology, Freiburg (Germany); Hankins, Jane S. [St. Jude Children' s Research Hospital, Department of Hematology, Memphis, TN (United States)

    2017-01-15

    Liver R2* values calculated from multi-gradient echo (mGRE) magnetic resonance images (MRI) are strongly correlated with hepatic iron concentration (HIC) as shown in several independently derived biopsy calibration studies. These calibrations were established for axial single-slice breath-hold imaging at the location of the portal vein. Scanning in multi-slice mode makes the exam more efficient, since whole-liver coverage can be achieved with two breath-holds and the optimal slice can be selected afterward. Navigator echoes remove the need for breath-holds and allow use in sedated patients. To evaluate if the existing biopsy calibrations can be applied to multi-slice and navigator-controlled mGRE imaging in children with hepatic iron overload, by testing if there is a bias-free correlation between single-slice R2* and multi-slice or multi-slice navigator controlled R2*. This study included MRI data from 71 patients with transfusional iron overload, who received an MRI exam to estimate HIC using gradient echo sequences. Patient scans contained 2 or 3 of the following imaging methods used for analysis: single-slice images (n = 71), multi-slice images (n = 69) and navigator-controlled images (n = 17). Small and large blood corrected region of interests were selected on axial images of the liver to obtain R2* values for all data sets. Bland-Altman and linear regression analysis were used to compare R2* values from single-slice images to those of multi-slice images and navigator-controlled images. Bland-Altman analysis showed that all imaging method comparisons were strongly associated with each other and had high correlation coefficients (0.98 ≤ r ≤ 1.00) with P-values ≤0.0001. Linear regression yielded slopes that were close to 1. We found that navigator-gated or breath-held multi-slice R2* MRI for HIC determination measures R2* values comparable to the biopsy-validated single-slice, single breath-hold scan. We conclude that these three R2* methods can be

  19. Improved biochemical preservation of heart slices during cold storage.

    Science.gov (United States)

    Bull, D A; Reid, B B; Connors, R C; Albanil, A; Stringham, J C; Karwande, S V

    2000-01-01

    Development of myocardial preservation solutions requires the use of whole organ models which are animal and labor intensive. These models rely on physiologic rather than biochemical endpoints, making accurate comparison of the relative efficacy of individual solution components difficult. We hypothesized that myocardial slices could be used to assess preservation of biochemical function during cold storage. Whole rat hearts were precision cut into slices with a thickness of 200 microm and preserved at 4 degrees C in one of the following solutions: Columbia University (CU), University of Wisconsin (UW), D5 0.2% normal saline with 20 meq/l KCL (QNS), normal saline (NS), or a novel cardiac preservation solution (NPS) developed using this model. Myocardial biochemical function was assessed by ATP content (etamoles ATP/mg wet weight) and capacity for protein synthesis (counts per minute (cpm)/mg protein) immediately following slicing (0 hours), and at 6, 12, 18, and 24 hours of cold storage. Six slices were assayed at each time point for each solution. The data were analyzed using analysis of variance and are presented as the mean +/- standard deviation. ATP content was higher in the heart slices stored in the NPS compared to all other solutions at 6, 12, 18 and 24 hours of cold storage (p cold storage (p cold storage.

  20. Evaluation of registration strategies for multi-modality images of rat brain slices

    International Nuclear Information System (INIS)

    Palm, Christoph; Vieten, Andrea; Salber, Dagmar; Pietrzyk, Uwe

    2009-01-01

    In neuroscience, small-animal studies frequently involve dealing with series of images from multiple modalities such as histology and autoradiography. The consistent and bias-free restacking of multi-modality image series is obligatory as a starting point for subsequent non-rigid registration procedures and for quantitative comparisons with positron emission tomography (PET) and other in vivo data. Up to now, consistency between 2D slices without cross validation using an inherent 3D modality is frequently presumed to be close to the true morphology due to the smooth appearance of the contours of anatomical structures. However, in multi-modality stacks consistency is difficult to assess. In this work, consistency is defined in terms of smoothness of neighboring slices within a single modality and between different modalities. Registration bias denotes the distortion of the registered stack in comparison to the true 3D morphology and shape. Based on these metrics, different restacking strategies of multi-modality rat brain slices are experimentally evaluated. Experiments based on MRI-simulated and real dual-tracer autoradiograms reveal a clear bias of the restacked volume despite quantitatively high consistency and qualitatively smooth brain structures. However, different registration strategies yield different inter-consistency metrics. If no genuine 3D modality is available, the use of the so-called SOP (slice-order preferred) or MOSOP (modality-and-slice-order preferred) strategy is recommended.

  1. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  2. Measures of large-scale structure in the CfA redshift survey slices

    International Nuclear Information System (INIS)

    De Lapparent, V.; Geller, M.J.; Huchra, J.P.

    1991-01-01

    Variations of the counts-in-cells with cell size are used here to define two statistical measures of large-scale clustering in three 6 deg slices of the CfA redshift survey. A percolation criterion is used to estimate the filling factor which measures the fraction of the total volume in the survey occupied by the large-scale structures. For the full 18 deg slice of the CfA redshift survey, f is about 0.25 + or - 0.05. After removing groups with more than five members from two of the slices, variations of the counts in occupied cells with cell size have a power-law behavior with a slope beta about 2.2 on scales from 1-10/h Mpc. Application of both this statistic and the percolation analysis to simulations suggests that a network of two-dimensional structures is a better description of the geometry of the clustering in the CfA slices than a network of one-dimensional structures. Counts-in-cells are also used to estimate at 0.3 galaxy h-squared/Mpc the average galaxy surface density in sheets like the Great Wall. 46 refs

  3. A novel lung slice system with compromised antioxidant defenses

    Energy Technology Data Exchange (ETDEWEB)

    Hardwick, S.J.; Adam, A.; Cohen, G.M. (Univ. of London (England)); Smith, L.L. (Imperial Chemical Industries PLC, Cheshire (England))

    1990-04-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 {mu}M) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP{sup +}, and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of {sup 14}CO{sub 2} from D-({sup 14}C(U))-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone.

  4. A novel lung slice system with compromised antioxidant defenses

    International Nuclear Information System (INIS)

    Hardwick, S.J.; Adam, A.; Cohen, G.M.; Smith, L.L.

    1990-01-01

    In order to facilitate the study of oxidative stress in lung tissue, rat lung slices with impaired antioxidant defenses were prepared and used. Incubation of lung slices with the antineoplastic agent 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) (100 μM) in an amino acid-rich medium for 45 min produced a near-maximal (approximately 85%), irreversible inhibition of glutathione reductase, accompanied by only a modest (approximately 15%) decrease in pulmonary nonprotein sulfhydryls (NPSH) and no alteration in intracellular ATP, NADP + , and NADPH levels. The amounts of NADP(H), ATP, and NPSH were stable over a 4-hr incubation period following the removal from BCNU. The viability of the system was further evaluated by measuring the rate of evolution of 14 CO 2 from D-[ 14 C(U)]-glucose. The rates of evolution were almost identical in the compromised system when compared with control slices over a 4-hr time period. By using slices with compromised oxidative defenses, preliminary results have been obtained with paraquat, nitrofurantoin, and 2,3-dimethoxy-1,4-naphthoquinone

  5. A Novel Approach for Transmission of 56 Gbit/s NRZ Signal in Access Network Using Spectrum Slicing Technique

    DEFF Research Database (Denmark)

    Spolitis, S.; Vegas Olmos, Juan José; Bobrovs, V.

    2013-01-01

    We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time.......We present the spectrum slicing and stitching concept for high-capacity low optics complexity optical access networks. Spectrum slicing and stitching of a 56 Gbit/s NRZ electrical signal is experimentally demonstrated for the first time....

  6. Study of Energy Consumption of Potato Slices During Drying Process

    Directory of Open Access Journals (Sweden)

    Hafezi Negar

    2015-06-01

    Full Text Available One of the new methods of food drying using infrared heating under vacuum is to increase the drying rate and maintain the quality of dried product. In this study, potato slices were dried using vacuum-infrared drying. Experiments were performed with the infrared lamp power levels 100, 150 and 200 W, absolute pressure levels 20, 80, 140 and 760 mmHg, and with three thicknesses of slices 1, 2 and 3 mm, in three repetitions. The results showed that the infrared lamp power, absolute pressure and slice thickness have important effects on the drying of potato. With increasing the radiation power, reducing the absolute pressure (acts of vacuum in the dryer chamber and also reducing the thickness of potato slices, drying time and the amount of energy consumed is reduced. In relation to thermal utilization efficiency, results indicated that with increasing the infrared radiation power and decreasing the absolute pressure, thermal efficiency increased.

  7. Velocity slice imaging for dissociative electron attachment

    Science.gov (United States)

    Nandi, Dhananjay; Prabhudesai, Vaibhav S.; Krishnakumar, E.; Chatterjee, A.

    2005-05-01

    A velocity slice imaging method is developed for measuring the angular distribution of fragment negative ions arising from dissociative electron attachment (DEA) to molecules. A low energy pulsed electron gun, a pulsed field ion extraction, and a two-dimensional position sensitive detector consisting of microchannel plates and a wedge-and-strip anode are used for this purpose. Detection and storage of each ion separately for its position and flight time allows analysis of the data offline for any given time slice, without resorting to pulsing the detector bias. The performance of the system is evaluated by measuring the angular distribution of O- from O2 and comparing it with existing data obtained using conventional technique. The capability of this technique in obtaining forward and backward angular distribution data is shown to have helped in resolving one of the existing problems in the electron scattering on O2.

  8. Effect of Slice Error of Glass on Zero Offset of Capacitive Accelerometer

    Science.gov (United States)

    Hao, R.; Yu, H. J.; Zhou, W.; Peng, B.; Guo, J.

    2018-03-01

    Packaging process had been studied on capacitance accelerometer. The silicon-glass bonding process had been adopted on sensor chip and glass, and sensor chip and glass was adhered on ceramic substrate, the three-layer structure was curved due to the thermal mismatch, the slice error of glass lead to asymmetrical curve of sensor chip. Thus, the sensitive mass of accelerometer deviated along the sensitive direction, which was caused in zero offset drift. It was meaningful to confirm the influence of slice error of glass, the simulation results showed that the zero output drift was 12.3×10-3 m/s2 when the deviation was 40μm.

  9. Scanning and contrast enhancement protocols for multi-slice CT in evaluation of the upper abdomen

    International Nuclear Information System (INIS)

    Awai, Kazuo; Onishi, Hiromitsu; Takada, Koichi; Yamaguchi, Yasuo; Eguchi, Nobuko; Hiraishi, Kumiko; Hori, Shinichi

    2000-01-01

    The advent of multi-slice CT is one of the quantum leaps in computed tomography since the introduction of helical CT. Multi-slice CT can rapidly scan a large longitudinal (z-axis) volume with high longitudinal resolution and low image artifacts. The rapid volume coverage speed of multi-slice CT can increase the difficulty in optimizing the delay time between the beginning of contrast material injection and the acquisition of images and we need accurate knowledge about optimal temporal window for adequate contrast enhancement. High z-axis resolution of multi-slice can improve the quality of three-dimensional images and MPR images and we must select adequate slice thickness and slice intervals in each case. We discuss basic considerations for adequate contrast enhancement and scanning protocols by multi-slice CT scanner in the upper abdomen. (author)

  10. Slicing, sampling, and distance-dependent effects affect network measures in simulated cortical circuit structures.

    Science.gov (United States)

    Miner, Daniel C; Triesch, Jochen

    2014-01-01

    The neuroanatomical connectivity of cortical circuits is believed to follow certain rules, the exact origins of which are still poorly understood. In particular, numerous nonrandom features, such as common neighbor clustering, overrepresentation of reciprocal connectivity, and overrepresentation of certain triadic graph motifs have been experimentally observed in cortical slice data. Some of these data, particularly regarding bidirectional connectivity are seemingly contradictory, and the reasons for this are unclear. Here we present a simple static geometric network model with distance-dependent connectivity on a realistic scale that naturally gives rise to certain elements of these observed behaviors, and may provide plausible explanations for some of the conflicting findings. Specifically, investigation of the model shows that experimentally measured nonrandom effects, especially bidirectional connectivity, may depend sensitively on experimental parameters such as slice thickness and sampling area, suggesting potential explanations for the seemingly conflicting experimental results.

  11. Cryopreservation of Precision-cut Tissue Slices for Application in Drug Metabolism Research

    NARCIS (Netherlands)

    Graaf, Inge Anne Maria de

    2002-01-01

    The research described in this thesis had two important aims. The first was to determine whether tissue slices could be used as an in vitro tool to predict the in vivo metabolism of new drugs. The second aim was to find a manner to store tissue slices for longer time periods by cryopreservation.

  12. Slicing, sampling, and distance-dependent effects affect network measures in simulated cortical circuit structures

    Directory of Open Access Journals (Sweden)

    Daniel Carl Miner

    2014-11-01

    Full Text Available The neuroanatomical connectivity of cortical circuits is believed to follow certain rules, the exact origins of which are still poorly understood. In particular, numerous nonrandom features, such as common neighbor clustering, overrepresentation of reciprocal connectivity, and overrepresentation of certain triadic graph motifs have been experimentally observed in cortical slice data. Some of these data, particularly regarding bidirectional connectivity are seemingly contradictory, and the reasons for this are unclear. Here we present a simple static geometric network model with distance-dependent connectivity on a realistic scale that naturally gives rise to certain elements of these observed behaviors, and may provide plausible explanations for some of the conflicting findings. Specifically, investigation of the model shows that experimentally measured nonrandom effects, especially bidirectional connectivity, may depend sensitively on experimental parameters such as slice thickness and sampling area, suggesting potential explanations for the seemingly conflicting experimental results.

  13. Color changes and acrylamide formation in fried potato slices

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Moyano, Pedro; Kaack, Karl

    2005-01-01

    The objective of this work was to study the kinetics of browning during deep-fat frying of blanched and unblanched potato chips by using the dynamic method and to find a relationship between browning development and acrylamide formation. Prior to frying, potato slices were blanched in hot water...... at 85degreesC for 3.5 min. Unblanched slices were used as the control. Control and blanched potato slices (Panda variety, diameter: 37 mm, width: 2.2 mm) were fried at 120, 150 and 180degreesC until reaching moisture contents of similar to1.8% (total basis) and their acrylamide content and final color...... were measured. Color changes were recorded at different sampling times during frying at the three mentioned temperatures using the chromatic redness parameter a(*). Experimental data of surface temperature, moisture content and color change in potato chips during frying were fit to empirical...

  14. A new crossed molecular beam apparatus using time-sliced ion velocity imaging technique

    International Nuclear Information System (INIS)

    Wu Guorong; Zhang Weiqing; Pan Huilin; Shuai Quan; Jiang Bo; Dai Dongxu; Yang Xueming

    2008-01-01

    A new crossed molecular beam apparatus has been constructed for investigating polyatomic chemical reactions using the time-sliced ion velocity map imaging technique. A unique design is adopted for one of the two beam sources and allows us to set up the molecular beam source either horizontally or vertically. This can be conveniently used to produce versatile atomic or radical beams from photodissociation and as well as electric discharge. Intensive H-atom beam source with high speed ratio was produced by photodissociation of the HI molecule and was reacted with the CD 4 molecule. Vibrational-state resolved HD product distribution was measured by detecting the CD 3 product. Preliminary results were also reported on the F+SiH 4 reaction using the discharged F atom beam. These results demonstrate that this new instrument is a powerful tool for investigating chemical dynamics of polyatomic reactions.

  15. Slice hyperholomorphic Schur analysis

    CERN Document Server

    Alpay, Daniel; Sabadini, Irene

    2016-01-01

    This book defines and examines the counterpart of Schur functions and Schur analysis in the slice hyperholomorphic setting. It is organized into three parts: the first introduces readers to classical Schur analysis, while the second offers background material on quaternions, slice hyperholomorphic functions, and quaternionic functional analysis. The third part represents the core of the book and explores quaternionic Schur analysis and its various applications. The book includes previously unpublished results and provides the basis for new directions of research.

  16. Measurement of time delay for a prospectively gated CT simulator.

    Science.gov (United States)

    Goharian, M; Khan, R F H

    2010-04-01

    For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patient's breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) 'X-Ray ON' status signal from the CT scanner in a text file. The TTL 'X-Ray ON' indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 +/- 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery

  17. [Standardization of production of process Notopterygii Rhizoma et Radix slices].

    Science.gov (United States)

    Sun, Zhen-Yang; Wang, Ying-Zi; Nie, Rui-Jie; Zhang, Jing-Zhen; Wang, Si-Yu

    2017-12-01

    Notopterol, isoimperatorin, volatile oil and extract (water and ethanol) were used as the research objects in this study to investigate the effects of different softening method, slice thickness and drying methods on the quality of Notopterygii Rhizoma et Radix slices, and the experimental data were analyzed by homogeneous distance evaluation method. The results showed that different softening, cutting and drying processes could affect the content of five components in Notopterygii Rhizoma et Radix incisum. The best processing technology of Notopterygii Rhizoma et Radix slices was as follows: non-medicinal parts were removed; mildewed and rot as well as moth-eaten parts were removed; washed by the flowing drinking water; stacked in the drug pool; moistening method was used for softening, where 1/8 volume of water was sprayed for every 1 kg of herbs every 2 h; upper part of herbs covered with clean and moist cotton, and cut into thick slices (2-4 mm) after 12 h moistening until appropriate softness, then received blast drying for 4 h at 50 ℃, and turned over for 2 times during the drying. The process is practical and provides the experimental basis for the standardization of the processing of Notopterygii Rhizoma et Radix, with great significance to improve the quality of Notopterygii Rhizoma et Radix slices. Copyright© by the Chinese Pharmaceutical Association.

  18. Target recognition of ladar range images using slice image: comparison of four improved algorithms

    Science.gov (United States)

    Xia, Wenze; Han, Shaokun; Cao, Jingya; Wang, Liang; Zhai, Yu; Cheng, Yang

    2017-07-01

    Compared with traditional 3-D shape data, ladar range images possess properties of strong noise, shape degeneracy, and sparsity, which make feature extraction and representation difficult. The slice image is an effective feature descriptor to resolve this problem. We propose four improved algorithms on target recognition of ladar range images using slice image. In order to improve resolution invariance of the slice image, mean value detection instead of maximum value detection is applied in these four improved algorithms. In order to improve rotation invariance of the slice image, three new improved feature descriptors-which are feature slice image, slice-Zernike moments, and slice-Fourier moments-are applied to the last three improved algorithms, respectively. Backpropagation neural networks are used as feature classifiers in the last two improved algorithms. The performance of these four improved recognition systems is analyzed comprehensively in the aspects of the three invariances, recognition rate, and execution time. The final experiment results show that the improvements for these four algorithms reach the desired effect, the three invariances of feature descriptors are not directly related to the final recognition performance of recognition systems, and these four improved recognition systems have different performances under different conditions.

  19. Prolonged life of human acute hippocampal slices from temporal lobe epilepsy surgery

    DEFF Research Database (Denmark)

    Wickham, J; Brödjegård, N G; Vighagen, R

    2018-01-01

    Resected hippocampal tissue from patients with drug-resistant epilepsy presents a unique possibility to test novel treatment strategies directly in target tissue. The post-resection time for testing and analysis however is normally limited. Acute tissue slices allow for electrophysiological...... granule whole-cell recordings, can be consistently induced in these slices, underlying the usefulness of this methodology for testing and/or validating novel treatment strategies for epilepsy....

  20. Integrating interface slicing into software engineering processes

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    Interface slicing is a tool which was developed to facilitate software engineering. As previously presented, it was described in terms of its techniques and mechanisms. The integration of interface slicing into specific software engineering activities is considered by discussing a number of potential applications of interface slicing. The applications discussed specifically address the problems, issues, or concerns raised in a previous project. Because a complete interface slicer is still under development, these applications must be phrased in future tenses. Nonetheless, the interface slicing techniques which were presented can be implemented using current compiler and static analysis technology. Whether implemented as a standalone tool or as a module in an integrated development or reverse engineering environment, they require analysis no more complex than that required for current system development environments. By contrast, conventional slicing is a methodology which, while showing much promise and intuitive appeal, has yet to be fully implemented in a production language environment despite 12 years of development.

  1. A survey of program slicing for software engineering

    Science.gov (United States)

    Beck, Jon

    1993-01-01

    This research concerns program slicing which is used as a tool for program maintainence of software systems. Program slicing decreases the level of effort required to understand and maintain complex software systems. It was first designed as a debugging aid, but it has since been generalized into various tools and extended to include program comprehension, module cohesion estimation, requirements verification, dead code elimination, and maintainence of several software systems, including reverse engineering, parallelization, portability, and reuse component generation. This paper seeks to address and define terminology, theoretical concepts, program representation, different program graphs, developments in static slicing, dynamic slicing, and semantics and mathematical models. Applications for conventional slicing are presented, along with a prognosis of future work in this field.

  2. Progress on the Femto-Slicing Project at the Synchrotron SOLEIL

    International Nuclear Information System (INIS)

    Prigent, P; Hollander, Ph; Labat, M; Couprie, M E; Marlats, J L; Laulhé, C; Luning, J; Moreno, T; Morin, P; Nadji, A; Polack, F; Ravy, S; Silly, M; Sirotti, F

    2013-01-01

    The aim of the Femto-Slicing project at SOLEIL is to generate 100 fs X-rays pulses on two beamlines, CRISTAL and TEMPO, for pump-probe experiments in the hard and soft X-rays regions. Two fs lasers are currently in operation on TEMPO and CRISTAL for pump-probe experiments on the ps time scale enabling time resolved photoemission and photodiffraction studies. The Femto-Slicing project is based on the fs laser of the CRISTAL beamline, which can be adjusted to deliver 3 mJ pulses of 30 fs duration at 2.5 kHz. The laser beam will be separated in three branches: one delivering about 2 mJ to the modulator Wiggler and the other ones delivering the remaining energy to the TEMPO and CRISTAL experiments. This layout will yield natural synchronization between IR laser pump and X-ray probe pulses, only affected by jitter associated with beam transport. In this paper, we present the current status of the Femto-Slicing project at SOLEIL, with particular emphasis on the expected performance, and the design and construction of the laser beam transport and the diagnostics implementation.

  3. Analysis and classification of commercial ham slice images using directional fractal dimension features.

    Science.gov (United States)

    Mendoza, Fernando; Valous, Nektarios A; Allen, Paul; Kenny, Tony A; Ward, Paddy; Sun, Da-Wen

    2009-02-01

    This paper presents a novel and non-destructive approach to the appearance characterization and classification of commercial pork, turkey and chicken ham slices. Ham slice images were modelled using directional fractal (DF(0°;45°;90°;135°)) dimensions and a minimum distance classifier was adopted to perform the classification task. Also, the role of different colour spaces and the resolution level of the images on DF analysis were investigated. This approach was applied to 480 wafer thin ham slices from four types of hams (120 slices per type): i.e., pork (cooked and smoked), turkey (smoked) and chicken (roasted). DF features were extracted from digitalized intensity images in greyscale, and R, G, B, L(∗), a(∗), b(∗), H, S, and V colour components for three image resolution levels (100%, 50%, and 25%). Simulation results show that in spite of the complexity and high variability in colour and texture appearance, the modelling of ham slice images with DF dimensions allows the capture of differentiating textural features between the four commercial ham types. Independent DF features entail better discrimination than that using the average of four directions. However, DF dimensions reveal a high sensitivity to colour channel, orientation and image resolution for the fractal analysis. The classification accuracy using six DF dimension features (a(90°)(∗),a(135°)(∗),H(0°),H(45°),S(0°),H(90°)) was 93.9% for training data and 82.2% for testing data.

  4. Drying characteristics of pumpkin ( Cucurbita moschata) slices in convective and freeze dryer

    Science.gov (United States)

    Caliskan, Gulsah; Dirim, Safiye Nur

    2017-06-01

    This study was intended to determine the drying and rehydration kinetics of convective and freeze dried pumpkin slices (0.5 × 3.5 × 0.5 cm). A pilot scale tray drier (at 80 ± 2 °C inlet temperature, 1 m s-1 air velocity) and freeze drier (13.33 kPa absolute pressure, condenser temperature of -48 ± 2 °C) were used for the drying experiments. Drying curves were fitted to six well-known thin layer drying models. Nonlinear regression analysis was used to evaluate the parameters of the selected models by using statistical software SPSS 16.0 (SPSS Inc., USA). For the convective and freeze drying processes of pumpkin slices, the highest R2 values, and the lowest RMSE as well as χ2 values were obtained from Page model. The effective moisture diffusivity (Deff) of the convective and freeze dried pumpkin slices were obtained from the Fick's diffusion model, and they were found to be 2.233 × 10-7 and 3.040 × 10-9 m2s-1, respectively. Specific moisture extraction rate, moisture extraction rate, and specific energy consumption values were almost twice in freeze drying process. Depending on the results, moisture contents and water activity values of pumpkin slices were in acceptable limits for safe storage of products. The rehydration behaviour of [at 18 ± 2 and 100 ± 2 °C for 1:25, 1:50, 1:75, 1:100, and 1:125 solid:liquid ratios (w:w)] dried pumpkin slices was determined by Peleg's model with the highest R2. The highest total soluble solid loss of pumpkin slices was observed for the rehydration experiment which performed at 1:25 solid: liquid ratio (w:w). Rehydration ratio of freeze dried slices was found 2-3 times higher than convective dried slices.

  5. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    Energy Technology Data Exchange (ETDEWEB)

    Ng, H.P. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Foong, K.W.C. [NUS Graduate School for Integrative Sciences and Engineering (Singapore); Dept. of Preventive Dentistry, National Univ. of Singapore (Singapore); Ong, S.H. [Dept. of Electrical and Computer Engineering, National Univ. of Singapore (Singapore); Div. of Bioengineering, National Univ. of Singapore (Singapore); Liu, J.; Nowinski, W.L. [Biomedical Imaging Lab., Agency for Science Technology and Research (Singapore); Goh, P.S. [Dept. of Diagnostic Radiology, National Univ. of Singapore (Singapore)

    2007-06-15

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices ({kappa}) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  6. Shape determinative slice localization for patient-specific masseter modeling using shape-based interpolation

    International Nuclear Information System (INIS)

    Ng, H.P.; Foong, K.W.C.; Ong, S.H.; Liu, J.; Nowinski, W.L.; Goh, P.S.

    2007-01-01

    The masseter plays a critical role in the mastication system. A hybrid method to shape-based interpolation is used to build the masseter model from magnetic resonance (MR) data sets. The main contribution here is the localizing of determinative slices in the data sets where clinicians are required to perform manual segmentations in order for an accurate model to be built. Shape-based criteria were used to locate the candidates for determinative slices and fuzzy-c-means (FCM) clustering technique was used to establish the determinative slices. Five masseter models were built in our work and the average overlap indices (κ) achieved is 85.2%. This indicates that there is good agreement between the models and the manual contour tracings. In addition, the time taken, as compared to manually segmenting all the slices, is significantly lesser. (orig.)

  7. Rat brain sagittal organotypic slice cultures as an ex vivo dopamine cell loss system.

    Science.gov (United States)

    McCaughey-Chapman, Amy; Connor, Bronwen

    2017-02-01

    Organotypic brain slice cultures are a useful tool to study neurological function as they provide a more complex, 3-dimensional system than standard 2-dimensional in vitro cell cultures. Building on a previously developed mouse brain slice culture protocol, we have developed a rat sagittal brain slice culture system as an ex vivo model of dopamine cell loss. We show that rat brain organotypic slice cultures remain viable for up to 6 weeks in culture. Using Fluoro-Gold axonal tracing, we demonstrate that the slice 3-dimensional cytoarchitecture is maintained over a 4 week culturing period, with particular focus on the nigrostriatal pathway. Treatment of the cultures with 6-hydroxydopamine and desipramine induces a progressive loss of Fluoro-Gold-positive nigral cells with a sustained loss of tyrosine hydroxylase-positive nigral cells. This recapitulates the pattern of dopaminergic degeneration observed in the rat partial 6-hydroxydopamine lesion model and, most importantly, the progressive pathology of Parkinson's disease. Our slice culture platform provides an advance over other systems, as we demonstrate for the first time 3-dimensional cytoarchitecture maintenance of rat nigrostriatal sagittal slices for up to 6 weeks. Our ex vivo organotypic slice culture system provides a long term cellular platform to model Parkinson's disease, allowing for the elucidation of mechanisms involved in dopaminergic neuron degeneration and the capability to study cellular integration and plasticity ex vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Simulating detectors dead time

    International Nuclear Information System (INIS)

    Rustom, Ibrahim Farog Ibrahim

    2015-06-01

    Nuclear detectors are used in all aspects of nuclear measurements. All nuclear detectors are characterized by their dead time i.e. the time needed by a detector to recover from a previous incident. A detector dead time influences measurements taken by a detector and specially when measuring high decay rate (>) where is the detector dead time. Two models are usually used to correct for the dead time effect: the paralayzable and the non-paralayzable models. In the current work we use Monte Carlo simulation techniques to simulate radioactivity and the effect of dead time and the count rate of a detector with a dead time =5x10 - 5s assuming the non-paralayzable model. The simulation indicates that assuming a non -paralayzable model could be used to correct for decay rate measured by a detector. The reliability of the non-paralayzable model to correct the measured decay rate could be gauged using the Monte Carlo simulation. (Author)

  9. Transmission of 2.5 Gbit/s Spectrum-sliced WDM System for 50 km Single-mode Fiber

    Science.gov (United States)

    Ahmed, Nasim; Aljunid, Sayed Alwee; Ahmad, R. Badlisha; Fadil, Hilal Adnan; Rashid, Mohd Abdur

    2011-06-01

    The transmission of a spectrum-sliced WDM channel at 2.5 Gbit/s for 50 km of single mode fiber using an system channel spacing only 0.4 nm is reported. We have investigated the system performance using NRZ modulation format. The proposed system is compared with conventional system. The system performance is characterized as the bit-error-rate (BER) received against the system bit rates. Simulation results show that the NRZ modulation format performs well for 2.5 Gbit/s system bit rates. Using this narrow channel spectrum-sliced technique, the total number of multiplexed channels can be increased greatly in WDM system. Therefore, 0.4 nm channel spacing spectrum-sliced WDM system is highly recommended for the long distance optical access networks, like the Metro Area Network (MAN), Fiber-to-the-Building (FTTB) and Fiber-to-the-Home (FTTH).

  10. Live cell imaging of cytosolic NADH/NAD+ ratio in hepatocytes and liver slices.

    Science.gov (United States)

    Masia, Ricard; McCarty, William J; Lahmann, Carolina; Luther, Jay; Chung, Raymond T; Yarmush, Martin L; Yellen, Gary

    2018-01-01

    Fatty liver disease (FLD), the most common chronic liver disease in the United States, may be caused by alcohol or the metabolic syndrome. Alcohol is oxidized in the cytosol of hepatocytes by alcohol dehydrogenase (ADH), which generates NADH and increases cytosolic NADH/NAD + ratio. The increased ratio may be important for development of FLD, but our ability to examine this question is hindered by methodological limitations. To address this, we used the genetically encoded fluorescent sensor Peredox to obtain dynamic, real-time measurements of cytosolic NADH/NAD + ratio in living hepatocytes. Peredox was expressed in dissociated rat hepatocytes and HepG2 cells by transfection, and in mouse liver slices by tail-vein injection of adeno-associated virus (AAV)-encoded sensor. Under control conditions, hepatocytes and liver slices exhibit a relatively low (oxidized) cytosolic NADH/NAD + ratio as reported by Peredox. The ratio responds rapidly and reversibly to substrates of lactate dehydrogenase (LDH) and sorbitol dehydrogenase (SDH). Ethanol causes a robust dose-dependent increase in cytosolic NADH/NAD + ratio, and this increase is mitigated by the presence of NAD + -generating substrates of LDH or SDH. In contrast to hepatocytes and slices, HepG2 cells exhibit a relatively high (reduced) ratio and show minimal responses to substrates of ADH and SDH. In slices, we show that comparable results are obtained with epifluorescence imaging and two-photon fluorescence lifetime imaging (2p-FLIM). Live cell imaging with Peredox is a promising new approach to investigate cytosolic NADH/NAD + ratio in hepatocytes. Imaging in liver slices is particularly attractive because it allows preservation of liver microanatomy and metabolic zonation of hepatocytes. NEW & NOTEWORTHY We describe and validate a new approach for measuring free cytosolic NADH/NAD + ratio in hepatocytes and liver slices: live cell imaging with the fluorescent biosensor Peredox. This approach yields dynamic, real-time

  11. Performance evaluation of a 64-slice CT system with z-flying focal spot.

    Science.gov (United States)

    Flohr, T; Stierstorfer, K; Raupach, R; Ulzheimer, S; Bruder, H

    2004-12-01

    The meanwhile established generation of 16-slice CT systems enables routine sub-millimeter imaging at short breath-hold times. Clinical progress in the development of multidetector row CT (MDCT) technology beyond 16 slices can more likely be expected from further improvement in spatial and temporal resolution rather than from a mere increase in the speed of volume coverage. We present an evaluation of a recently introduced 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany), which uses a periodic motion of the focal spot in longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. This technique acquires 64 overlapping 0.6 mm slices per rotation. The sampling scheme corresponds to that of a 64 x 0.3 mm detector, with the goal of improved longitudinal resolution and reduced spiral artifacts. After an introduction to the detector design, we discuss the basics of z-flying focal spot technology (z-Sharp). We present phantom and specimen scans for performance evaluation. The measured full width at half maximum (FWHM) of the thinnest spiral slice is 0.65 mm. All spiral slice widths are almost independent of the pitch, with deviations of less than 0.1 mm from the nominal value. Using a high-resolution bar pattern phantom (CATPHAN, Phantom Laboratories, Salem, NY), the longitudinal resolution can be demonstrated to be up to 15 lp/cm at the isocenter independent of the pitch, corresponding to a bar diameter of 0.33 mm. Longitudinal resolution is only slightly degraded for off-center locations. At a distance of 100 mm from the isocenter, 14 lp/cm can be resolved in the z-direction, corresponding to a bar diameter of 0.36 mm. Spiral "windmill" artifacts presenting as hyper- and hypodense structures around osseous edges are effectively reduced by the z-flying focal spot technique. Cardiac scanning benefits from the short gantry rotation time of 0.33 s, providing up to 83 ms temporal resolution with 2-segment ECG

  12. Thin slices of child personality: Perceptual, situational, and behavioral contributions.

    Science.gov (United States)

    Tackett, Jennifer L; Herzhoff, Kathrin; Kushner, Shauna C; Rule, Nicholas

    2016-01-01

    The present study examined whether thin-slice ratings of child personality serve as a resource-efficient and theoretically valid measurement of child personality traits. We extended theoretical work on the observability, perceptual accuracy, and situational consistency of childhood personality traits by examining intersource and interjudge agreement, cross-situational consistency, and convergent, divergent, and predictive validity of thin-slice ratings. Forty-five unacquainted independent coders rated 326 children's (ages 8-12) personality in 1 of 15 thin-slice behavioral scenarios (i.e., 3 raters per slice, for over 14,000 independent thin-slice ratings). Mothers, fathers, and children rated children's personality, psychopathology, and competence. We found robust evidence for correlations between thin-slice and mother/father ratings of child personality, within- and across-task consistency of thin-slice ratings, and convergent and divergent validity with psychopathology and competence. Surprisingly, thin-slice ratings were more consistent across situations in this child sample than previously found for adults. Taken together, these results suggest that thin slices are a valid and reliable measure to assess child personality, offering a useful method of measurement beyond questionnaires, helping to address novel questions of personality perception and consistency in childhood. (c) 2016 APA, all rights reserved).

  13. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  14. Slices

    KAUST Repository

    McCrae, James

    2011-01-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours of intersection of planes with a 3D object, for creating shape abstractions, motivated by their popularity in art and engineering. We first perform a user study to show that humans do define consistent and similar planar section proxies for common objects. Interestingly, we observe a strong correlation between user-defined planes and geometric features of objects. Further we show that the problem of finding the minimum set of planes that capture a set of 3D geometric shape features is both NP-hard and not always the proxy a user would pick. Guided by the principles inferred from our user study, we present an algorithm that progressively selects planes to maximize feature coverage, which in turn influence the selection of subsequent planes. The algorithmic framework easily incorporates various shape features, while their relative importance values are computed and validated from the user study data. We use our algorithm to compute planar slices for various objects, validate their utility towards object abstraction using a second user study, and conclude showing the potential applications of the extracted planar slice shape proxies. © 2011 ACM.

  15. Correlation of NTD-silicon rod and slice resistivity

    International Nuclear Information System (INIS)

    Wolverton, W.M.

    1984-01-01

    Neutron transmutation doped silicon is an electronic material which presents an opportunity to explore a high level of resistivity characterization. This is due to its excellent uniformity of dopant concentration. Appropriate resistivity measurements on the ingot raw material can be used as a predictor of slice resistivity. Correlation of finished NTD rod (i.e. ingot) resistivity to as-cut slice resistivity (after the sawing process) is addressed in the scope of this paper. Empirical data show that the shift of slice-center resistivity compared to rod-end center resistivity is a function of a new kind of rod radial-resistivity gradient. This function has two domains, and most rods are in domain ''A''. Correlating equations show how to significantly improve the prediction of slice resistivity of rods in domain ''A''. The new rod resistivity specifications have resulted in manufacturing economies in the production of NTD silicon slices

  16. Antibrowning and antimicrobial properties of sodium acid sulfate in apple slices.

    Science.gov (United States)

    Fan, Xuetong; Sokorai, Kimberly J B; Liao, Ching-Hsing; Cooke, Peter; Zhang, Howard Q

    2009-01-01

    There are few available compounds that can both control browning and enhance microbial safety of fresh-cut fruits. In the present study, the antibrowning ability of sodium acid sulfate (SAS) on "Granny Smith" apple slices was first investigated in terms of optimum concentration and treatment time. In a separate experiment, the apple slices were treated with water or 3% of SAS, calcium ascorbate, citric acid, or acidified calcium sulfate for 5 min. Total plate count, color, firmness, and tissue damage were assessed during a 21-d storage at 4 degrees C. Results showed that the efficacy of SAS in inhibiting browning of apple slices increased with increasing concentration. A minimum 3% of SAS was needed to achieve 14 d of shelf life. Firmness was not significantly affected by SAS at 3% or lower concentrations. Antibrowning potential of SAS was similar for all treatment times ranging from 2 to 10 min. However, SAS caused some skin discoloration of apple slices. When cut surface of apple slices were stained with a fluorescein diacetate solution, tissue damage could be observed under a microscope even though visual damage was not evident. Among the antibrowning agents tested, SAS was the most effective in inhibiting browning and microbial growth for the first 14 d. Total plate count of samples treated with 3% SAS was significantly lower than those treated with calcium ascorbate, a commonly used antibrowning agent. Our results suggested that it is possible to use SAS to control browning while inhibiting the growth of microorganisms on the apple slices if the skin damage can be minimized. Practical Application: Fresh-cut apples have emerged as one of the popular products in restaurants, schools, and food service establishments as more consumers demand fresh, convenient, and nutritious foods. Processing of fresh-cut apples induces mechanical damage to the fruit and exposes apple tissue to air, resulting in the development of undesirable tissue browning. The fresh

  17. Measurement of time delay for a prospectively gated CT simulator

    Directory of Open Access Journals (Sweden)

    Goharian M

    2010-01-01

    Full Text Available For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patient′s breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore™ (Philips Medical Systems, Madison, WI scanner attached to a Varian Real-Time Position Management™ (RPM system (Varian Medical Systems, Palo Alto, CA was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL ′X-Ray ON′ status signal from the CT scanner in a text file. The TTL ′X-Ray ON′ indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 ± 40 ms. The delay requires corrections both at image acquisition and while setting gates for

  18. Measurement of time delay for a prospectively gated CT simulator

    International Nuclear Information System (INIS)

    Goharian, M.; Khan, R.F.H.

    2010-01-01

    For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-set during a selected phase of the patient's breathing cycle. The purpose of the present work is to present a simple technique to measure the time delay during acquisition of a prospectively gated CT. The time delay of a Philips Brilliance BigBore (Philips Medical Systems, Madison, WI) scanner attached to a Varian Real-Time Position Management (RPM) system (Varian Medical Systems, Palo Alto, CA) was measured. Two methods were used to measure the CT time delay: using a motion phantom and using a recorded data file from the RPM system. In the first technique, a rotating wheel phantom was altered by placing two plastic balls on its axis and rim, respectively. For a desired gate, the relative positions of the balls were measured from the acquired CT data and converted into corresponding phases. Phase difference was calculated between the measured phases and the desired phases. Using period of motion, the phase difference was converted into time delay. The Varian RPM system provides an external breathing signal; it also records transistor-transistor logic (TTL) 'X-Ray ON' status signal from the CT scanner in a text file. The TTL 'X-Ray ON' indicates the start of CT image acquisition. Thus, knowledge of the start time of CT acquisition, combined with the real-time phase and amplitude data from the external respiratory signal, provides time-stamping of all images in an axial CT scan. The TTL signal with time-stamp was used to calculate when (during the breathing cycle) a slice was recorded. Using the two approaches, the time delay between the prospective gating signal and CT simulator has been determined to be 367 ± 40 ms. The delay requires corrections both at image acquisition and while setting gates for the treatment delivery

  19. Mathematical Modeling of Thin Layer Microwave Drying of Taro Slices

    Science.gov (United States)

    Kumar, Vivek; Sharma, H. K.; Singh, K.

    2016-03-01

    The present study investigated the drying kinetics of taro slices precooked in different medium viz water (WC), steam (SC) and Lemon Solution (LC) and dried at different microwave power 360, 540 and 720 W. Drying curves of all precooked slices at all microwave powers showed falling rate period along with a very short accelerating period at the beginning of the drying. At all microwave powers, higher drying rate was observed for LC slices as compared to WC and SC slices. To select a suitable drying curve, seven thin-layer drying models were fitted to the experimental data. The data revealed that the Page model was most adequate in describing the microwave drying behavior of taro slices precooked in different medium. The highest effective moisture diffusivity value of 2.11 × 10-8 m2/s was obtained for LC samples while the lowest 0.83 × 10-8 m2/s was obtained for WC taro slices. The activation energy (E a ) of LC taro slices was lower than the E a of WC and SC taro slices.

  20. Impact of whey protein coating incorporated with Bifidobacterium and Lactobacillus on sliced ham properties.

    Science.gov (United States)

    Odila Pereira, Joana; Soares, José; J P Monteiro, Maria; Gomes, Ana; Pintado, Manuela

    2018-05-01

    Edible coatings/films with functional ingredients may be a solution to consumers' demands for high-quality food products and an extended shelf-life. The aim of this work was to evaluate the antimicrobial efficiency of edible coatings incorporated with probiotics on sliced ham preservation. Coatings was developed based on whey protein isolates with incorporation of Bifidobacterium animalis Bb-12® or Lactobacillus casei-01. The physicochemical analyses showed that coating decreased water and weight loss on the ham. Furthermore, color analysis showed that coated sliced ham, exhibited no color change, comparatively to uncoated slices. The edible coatings incorporating the probiotic strains inhibited detectable growth of Staphylococcus spp., Pseudomonas spp., Enterobacteriaceae and yeasts/molds, at least, for 45days of storage at 4°C. The sensory evaluation demonstrated that there was a preference for the sliced coated ham. Probiotic bacteria viable cell numbers were maintained at ca. 10 8 CFU/g throughout storage time, enabling the slice of ham to act as a suitable carrier for the beneficial bacteria. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Blanching, salting and sun drying of different pumpkin fruit slices.

    Science.gov (United States)

    Workneh, T S; Zinash, A; Woldetsadik, K

    2014-11-01

    The study was aimed at assessing the quality of pumpkin (Cucuribita Spp.) slices that were subjected to pre-drying treatments and drying using two drying methods (uncontrolled sun and oven) fruit accessions. Pre-drying had significant (P ≤ 0.05) effect on the quality of dried pumpkin slices. 10 % salt solution dipped pumpkin fruit slices had good chemical quality. The two-way interaction between drying methods and pre-drying treatments had significant (P ≤ 0.05) effect on chemical qualities. Pumpkin subjected to salt solution dipping treatment and oven dried had higher chemical concentrations. Among the pumpkin fruit accessions, pumpkin accession 8007 had the superior TSS, total sugar and sugar to acid ratio after drying. Among the three pre-drying treatment, salt solution dipping treatment had significant (P ≤ 0.05) effect and the most efficient pre-drying treatment to retain the quality of dried pumpkin fruits without significant chemical quality deterioration. Salt dipping treatment combined with low temperature (60 °C) oven air circulation drying is recommended to maintain quality of dried pumpkin slices. However, since direct sun drying needs extended drying time due to fluctuation in temperature, it is recommended to develop or select best successful solar dryer for use in combination with pre-drying salt dipping or blanching treatments.

  2. Water-activity of dehydrated guava slices sweeteners

    International Nuclear Information System (INIS)

    Ayub, M.; Zeb, A.; Ullah, J.

    2005-01-01

    A study was carried out to investigate the individual and combined effect of caloric sweeteners (sucrose, glucose and fructose) and non-caloric sweeteners (saccharine, cyclamate and aspartame) along with antioxidants (citric acid and ascorbic acid) and chemical preservatives (potassium metabisulphite and potassium sorbate) on the water-activity (a/sub w/) of dehydrated guava slices. Different dilutions of caloric sweeteners (20, 30, 40 and 50 degree brix (bx) and non-caloric sweeteners (equivalent to sucrose sweetness) were used. Guava slices were osmotically dehydrated in these solutions and then dehydrated initially at 0 and then at 60 degree C to final moisture-content of 20-25%. Guava slices prepared with sucrose: glucose 7:3 potassium metabisulphite, ascorbic acid and citric acid produced best quality products, which have minimum (a/sub w/) and best overall sensory characteristics. The analysis showed that treatments and their various concentrations had a significant effect (p=0.05) on (a/sub w/) of dehydrated guava slices. (author)

  3. Interactive Slice of the CMS detector

    CERN Multimedia

    Davis, Siona Ruth

    2016-01-01

    This slice shows a colorful cross-section of the CMS detector with all parts of the detector labelled. Viewers are invited to click on buttons associated with five types of particles to see what happens when each type interacts with the sections of the detector. The five types of particles users can select to send through the slice are muons, electrons, neutral hadrons, charged hadrons and photons. Supplementary information on each type of particles is given. Useful for inclusion into general talks on CMS etc. *Animated CMS "slice" for Powerpoint (Mac & PC) Original version - 2004 Updated version - July 2010 *Six slides required - first is a set of buttons; others are for each particle type (muon, electron, charged/neutral hadron, photon) Recommend putting slide 1 anywhere in your presentation and the rest at the end

  4. Development of a bread slicing machine from locally sourced ...

    African Journals Online (AJOL)

    This paper presents the development of a bread slicing machine which is a mechanical device that is used for slicing bread instead of the crude cumbersome and unhygienic method of manual slicing of bread. In an attempt to facilitate the final processing of bread which is a common daily food requirement of most Nigerians ...

  5. Short-scan-time multi-slice diffusion MRI of the mouse cervical spinal cord using echo planar imaging.

    Science.gov (United States)

    Callot, Virginie; Duhamel, Guillaume; Cozzone, Patrick J; Kober, Frank

    2008-10-01

    Mouse spinal cord (SC) diffusion-weighted imaging (DWI) provides important information on tissue morphology and structural changes that may occur during pathologies such as multiple sclerosis or SC injury. The acquisition scheme of the commonly used DWI techniques is based on conventional spin-echo encoding, which is time-consuming. The purpose of this work was to investigate whether the use of echo planar imaging (EPI) would provide good-quality diffusion MR images of mouse SC, as well as accurate measurements of diffusion-derived metrics, and thus enable diffusion tensor imaging (DTI) and highly resolved DWI within reasonable scan times. A four-shot diffusion-weighted spin-echo EPI (SE-EPI) sequence was evaluated at 11.75 T on a group of healthy mice (n = 10). SE-EPI-derived apparent diffusion coefficients of gray and white matter were compared with those obtained using a conventional spin-echo sequence (c-SE) to validate the accuracy of the method. To take advantage of the reduction in acquisition time offered by the EPI sequence, multi-slice DTI acquisitions were performed covering the cervical segments (six slices, six diffusion-encoding directions, three b values) within 30 min (vs 2 h for c-SE). From these measurements, fractional anisotropy and mean diffusivities were calculated, and fiber tracking along the C1 to C6 cervical segments was performed. In addition, high-resolution images (74 x 94 microm(2)) were acquired within 5 min per direction. Clear delineation of gray and white matter and identical apparent diffusion coefficient values were obtained, with a threefold reduction in acquisition time compared with c-SE. While overcoming the difficulties associated with high spatially and temporally resolved DTI measurements, the present SE-EPI approach permitted identification of reliable quantitative parameters with a reproducibility compatible with the detection of pathologies. The SE-EPI method may be particularly valuable when multiple sets of images

  6. Cardiac tissue slices: preparation, handling, and successful optical mapping.

    Science.gov (United States)

    Wang, Ken; Lee, Peter; Mirams, Gary R; Sarathchandra, Padmini; Borg, Thomas K; Gavaghan, David J; Kohl, Peter; Bollensdorff, Christian

    2015-05-01

    Cardiac tissue slices are becoming increasingly popular as a model system for cardiac electrophysiology and pharmacology research and development. Here, we describe in detail the preparation, handling, and optical mapping of transmembrane potential and intracellular free calcium concentration transients (CaT) in ventricular tissue slices from guinea pigs and rabbits. Slices cut in the epicardium-tangential plane contained well-aligned in-slice myocardial cell strands ("fibers") in subepicardial and midmyocardial sections. Cut with a high-precision slow-advancing microtome at a thickness of 350 to 400 μm, tissue slices preserved essential action potential (AP) properties of the precutting Langendorff-perfused heart. We identified the need for a postcutting recovery period of 36 min (guinea pig) and 63 min (rabbit) to reach 97.5% of final steady-state values for AP duration (APD) (identified by exponential fitting). There was no significant difference between the postcutting recovery dynamics in slices obtained using 2,3-butanedione 2-monoxime or blebistatin as electromechanical uncouplers during the cutting process. A rapid increase in APD, seen after cutting, was caused by exposure to ice-cold solution during the slicing procedure, not by tissue injury, differences in uncouplers, or pH-buffers (bicarbonate; HEPES). To characterize intrinsic patterns of CaT, AP, and conduction, a combination of multipoint and field stimulation should be used to avoid misinterpretation based on source-sink effects. In summary, we describe in detail the preparation, mapping, and data analysis approaches for reproducible cardiac tissue slice-based investigations into AP and CaT dynamics. Copyright © 2015 the American Physiological Society.

  7. Geometry Processing of Conventionally Produced Mouse Brain Slice Images.

    Science.gov (United States)

    Agarwal, Nitin; Xu, Xiangmin; Gopi, M

    2018-04-21

    Brain mapping research in most neuroanatomical laboratories relies on conventional processing techniques, which often introduce histological artifacts such as tissue tears and tissue loss. In this paper we present techniques and algorithms for automatic registration and 3D reconstruction of conventionally produced mouse brain slices in a standardized atlas space. This is achieved first by constructing a virtual 3D mouse brain model from annotated slices of Allen Reference Atlas (ARA). Virtual re-slicing of the reconstructed model generates ARA-based slice images corresponding to the microscopic images of histological brain sections. These image pairs are aligned using a geometric approach through contour images. Histological artifacts in the microscopic images are detected and removed using Constrained Delaunay Triangulation before performing global alignment. Finally, non-linear registration is performed by solving Laplace's equation with Dirichlet boundary conditions. Our methods provide significant improvements over previously reported registration techniques for the tested slices in 3D space, especially on slices with significant histological artifacts. Further, as one of the application we count the number of neurons in various anatomical regions using a dataset of 51 microscopic slices from a single mouse brain. To the best of our knowledge the presented work is the first that automatically registers both clean as well as highly damaged high-resolutions histological slices of mouse brain to a 3D annotated reference atlas space. This work represents a significant contribution to this subfield of neuroscience as it provides tools to neuroanatomist for analyzing and processing histological data. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Multiple single-unit long-term tracking on organotypic hippocampal slices using high-density microelectrode arrays

    Directory of Open Access Journals (Sweden)

    Wei Gong

    2016-11-01

    Full Text Available A novel system to cultivate and record from organotypic brain slices directly on high-density microelectrode arrays (HD-MEA was developed. This system allows for continuous recording of electrical activity of specific individual neurons at high spatial resolution while monitoring at the same time, neuronal network activity. For the first time, the electrical activity patterns of single neurons and the corresponding neuronal network in an organotypic hippocampal slice culture were studied during several consecutive weeks at daily intervals. An unsupervised iterative spike-sorting algorithm, based on PCA and k-means clustering, was developed to assign the activities to the single units. Spike-triggered average extracellular waveforms of an action potential recorded across neighboring electrodes, termed ‘footprints’ of single-units were generated and tracked over weeks. The developed system offers the potential to study chronic impacts of drugs or genetic modifications on individual neurons in slice preparations over extended times.

  9. Influence of γ-irradiation on drying of slice potato

    International Nuclear Information System (INIS)

    Wang Jun; Chao Yan; Fu Junjie; Wang Jianping

    2001-01-01

    A new technology is introduced to dry food products by hot-air after pretreated by irradiation. The influence of different dosage of irradiation, temperature of hot air, thickness of the slice potato on the rate of dehydration temperature of irradiated potato were studied. A conclusion is reached that the 3 factors, irradiation dosage, hot-air temperature and thickness of slice potato, affect the rate of dehydration and temperature of slice potato. The higher the dosage is, the greater the rate of dehydration of potato becomes, and the higher the temperature of the slice potato gets. (authors)

  10. Influence of the slice thickness in CT to clinical effect

    International Nuclear Information System (INIS)

    Kimura, Kazue; Katakura, Toshihiko; Ito, Masami; Okuaki, Okihisa; Suzuki, Kenji

    1980-01-01

    CT is a kind of tomography. Therefore, what thickness of tissue is being observed in the picture - this is important in the clinical application of CT. The influence of slice thickness on the pictures, especially its clinical effect, was examined. The apparatus used is EMI CT 5005. For varying the slice thickness, it cannot be any larger than the thickness essential to the apparatus. Therefore, to make it thinner than the essential 14 mm, collimators were specially prepared, which were used on the sides of an X-ray tube and a detector. As basic observation, the revelation ability of form owing to the difference of slice thickness using acryl pipes, and the revelation ability of slice face owing to the difference of slice thickness, were examined. About clinical observation, the results for certain cases of cancer were compared with the CT images for the slice thickness of 14 mm essential to EMI CT 5005 and the slice thickness of 7 mm achieved by means of the collimators. (J.P.N.)

  11. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  12. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio [University Hospital ' ' S.Orsola' ' , Cardio-Thoracic-Vascular Department, Cardio-Thoracic Radiology Unit, Bologna (Italy)

    2016-02-15

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  13. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio

    2016-01-01

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  14. A novel method for oxygen glucose deprivation model in organotypic spinal cord slices.

    Science.gov (United States)

    Liu, Jing-Jie; Ding, Xiao-Yan; Xiang, Li; Zhao, Feng; Huang, Sheng-Li

    2017-10-01

    This study aimed to establish a model to closely mimic spinal cord hypoxic-ischemic injury with high production and high reproducibility. Fourteen-day cultured organotypic spinal cord slices were divided into 4 groups: control (Ctrl), oxygen glucose deprived for 30min (OGD 30min), OGD 60min, and OGD 120min. The Ctrl slices were incubated with 1ml propidium iodide (PI) solution (5μg/ml) for 30min. The OGD groups were incubated with 1ml glucose-free DMEM/F12 medium and 5μl PI solution (1mg/ml) for 30min, 60min and 120min, respectively. Positive control slice was fixed by 4% paraformaldehyde for 20min. The culture medium in each group was then collected and the Lactate Dehydrogenase (LDH) level in the medium was tested using Multi-Analyte ELISArray kits. Structure and refraction of the spinal cord slices were observed by light microscope. Fluorescence intensity of PI was examined by fluorescence microscopy and was tested by IPP Software. Morphology of astrocytes was observed by immunofluorescence histochemistry. Caspase 3 and caspase 3 active in different groups were tested by Western blot. In the OGD groups, the refraction of spinal cord slices decreased and the structure was unclear. The changes of refraction and structure in the OGD 120min group were similar to that in the positive control slice. Astrocyte morphology changed significantly. With the increase of OGD time, processes became thick and twisted, and nuclear condensations became more apparent. Obvious changes in morphology were observed in the OGD 60min group, and normal morphology disappeared in the OGD 120min group. Fluorescence intensity of PI increased along with the extension of OGD time. The difference was significant between 30min and 60min, but not significant between 60min and 120min. The intensity at OGD 120min was close to that in the positive control. Compare with the Ctrl group, the OGD groups had significantly higher LDH levels and caspase 3 active/caspase 3 ratios. The values increased

  15. Thin-Slice Measurement of Wisdom

    Directory of Open Access Journals (Sweden)

    Chao S. Hu

    2017-08-01

    Full Text Available Objective Measurement of Wisdom within a short period of time is vital for both the public interest (e.g., understanding a presidential election and research (e.g., testing factors that facilitate wisdom development. A measurement of emotion associated with wisdom would be especially informative; therefore, a novel Thin-Slice measurement of wisdom was developed based on the Berlin Paradigm. For about 2 min, participants imagined the lens of a camera as the eyes of their friend/teacher whom they advised about a life dilemma. Verbal response and facial expression were both recorded by a camera: verbal responses were then rated on both the Berlin Wisdom criteria and newly developed Chinese wisdom criteria; facial expressions were analyzed by the software iMotion FACET module. Results showed acceptable inter-rater and inter-item reliability for this novel paradigm. Moreover, both wisdom ratings were not significantly correlated with Social desirability, and the Berlin wisdom rating was significantly negatively correlated with Neuroticism; feeling of surprise was significantly positively correlated with both wisdom criteria ratings. Our results provide the first evidence of this Thin-slice Wisdom Paradigm’s reliability, its immunity to social desirability, and its validity for assessing candidates’ wisdom within a short timeframe. Although still awaiting further development, this novel Paradigm contributes to an emerging Universal Wisdom Paradigm applicable across cultures.

  16. Slicing Method for curved façade and window extraction from point clouds

    Science.gov (United States)

    Iman Zolanvari, S. M.; Laefer, Debra F.

    2016-09-01

    Laser scanning technology is a fast and reliable method to survey structures. However, the automatic conversion of such data into solid models for computation remains a major challenge, especially where non-rectilinear features are present. Since, openings and the overall dimensions of the buildings are the most critical elements in computational models for structural analysis, this article introduces the Slicing Method as a new, computationally-efficient method for extracting overall façade and window boundary points for reconstructing a façade into a geometry compatible for computational modelling. After finding a principal plane, the technique slices a façade into limited portions, with each slice representing a unique, imaginary section passing through a building. This is done along a façade's principal axes to segregate window and door openings from structural portions of the load-bearing masonry walls. The method detects each opening area's boundaries, as well as the overall boundary of the façade, in part, by using a one-dimensional projection to accelerate processing. Slices were optimised as 14.3 slices per vertical metre of building and 25 slices per horizontal metre of building, irrespective of building configuration or complexity. The proposed procedure was validated by its application to three highly decorative, historic brick buildings. Accuracy in excess of 93% was achieved with no manual intervention on highly complex buildings and nearly 100% on simple ones. Furthermore, computational times were less than 3 sec for data sets up to 2.6 million points, while similar existing approaches required more than 16 hr for such datasets.

  17. IMF-Slices for GPR Data Processing Using Variational Mode Decomposition Method

    Directory of Open Access Journals (Sweden)

    Xuebing Zhang

    2018-03-01

    Full Text Available Using traditional time-frequency analysis methods, it is possible to delineate the time-frequency structures of ground-penetrating radar (GPR data. A series of applications based on time-frequency analysis were proposed for the GPR data processing and imaging. With respect to signal processing, GPR data are typically non-stationary, which limits the applications of these methods moving forward. Empirical mode decomposition (EMD provides alternative solutions with a fresh perspective. With EMD, GPR data are decomposed into a set of sub-components, i.e., the intrinsic mode functions (IMFs. However, the mode-mixing effect may also bring some negatives. To utilize the IMFs’ benefits, and avoid the negatives of the EMD, we introduce a new decomposition scheme termed variational mode decomposition (VMD for GPR data processing for imaging. Based on the decomposition results of the VMD, we propose a new method which we refer as “the IMF-slice”. In the proposed method, the IMFs are generated by the VMD trace by trace, and then each IMF is sorted and recorded into different profiles (i.e., the IMF-slices according to its center frequency. Using IMF-slices, the GPR data can be divided into several IMF-slices, each of which delineates a main vibration mode, and some subsurface layers and geophysical events can be identified more clearly. The effectiveness of the proposed method is tested using synthetic benchmark signals, laboratory data and the field dataset.

  18. Introduction to bit slices and microprogramming

    International Nuclear Information System (INIS)

    Van Dam, A.

    1981-01-01

    Bit-slice logic blocks are fourth-generation LSI components which are natural extensions of traditional mulitplexers, registers, decoders, counters, ALUs, etc. Their functionality is controlled by microprogramming, typically to implement CPUs and peripheral controllers where both speed and easy programmability are required for flexibility, ease of implementation and debugging, etc. Processors built from bit-slice logic give the designer an alternative for approaching the programmibility of traditional fixed-instruction-set microprocessors with a speed closer to that of hardwired random logic. (orig.)

  19. Tumor Slice Culture: A New Avatar in Personalized Oncology

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-16-1-0149 TITLE: Tumor Slice Culture: A New Avatar in Personalized Oncology PRINCIPAL INVESTIGATOR: Raymond Yeung...CONTRACT NUMBER Tumor Slice Culture: A New Avatar in Personalized Oncology 5b. GRANT NUMBER W81XWH-16-1-0149 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...10 Annual Report 2017: Tumor Slice Culture: A new avatar for personalized oncology 1. INTRODUCTION: The goal of this research is to advance our

  20. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  1. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  2. VERSE - Virtual Equivalent Real-time Simulation

    Science.gov (United States)

    Zheng, Yang; Martin, Bryan J.; Villaume, Nathaniel

    2005-01-01

    Distributed real-time simulations provide important timing validation and hardware in the- loop results for the spacecraft flight software development cycle. Occasionally, the need for higher fidelity modeling and more comprehensive debugging capabilities - combined with a limited amount of computational resources - calls for a non real-time simulation environment that mimics the real-time environment. By creating a non real-time environment that accommodates simulations and flight software designed for a multi-CPU real-time system, we can save development time, cut mission costs, and reduce the likelihood of errors. This paper presents such a solution: Virtual Equivalent Real-time Simulation Environment (VERSE). VERSE turns the real-time operating system RTAI (Real-time Application Interface) into an event driven simulator that runs in virtual real time. Designed to keep the original RTAI architecture as intact as possible, and therefore inheriting RTAI's many capabilities, VERSE was implemented with remarkably little change to the RTAI source code. This small footprint together with use of the same API allows users to easily run the same application in both real-time and virtual time environments. VERSE has been used to build a workstation testbed for NASA's Space Interferometry Mission (SIM PlanetQuest) instrument flight software. With its flexible simulation controls and inexpensive setup and replication costs, VERSE will become an invaluable tool in future mission development.

  3. TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

    International Nuclear Information System (INIS)

    Harris, W; Yin, F; Wang, C; Chang, Z; Cai, J; Zhang, Y; Ren, L

    2016-01-01

    Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI_MM-ROI_FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while

  4. TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

    Energy Technology Data Exchange (ETDEWEB)

    Harris, W; Yin, F; Wang, C; Chang, Z; Cai, J; Zhang, Y; Ren, L [Duke University Medical Center, Durham, NC (United States)

    2016-06-15

    Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while

  5. Endogenous 24S-hydroxycholesterol modulates NMDAR-mediated function in hippocampal slices.

    Science.gov (United States)

    Sun, Min-Yu; Izumi, Yukitoshi; Benz, Ann; Zorumski, Charles F; Mennerick, Steven

    2016-03-01

    N-methyl-D-aspartate receptors (NMDARs), a major subtype of glutamate receptors mediating excitatory transmission throughout the central nervous system (CNS), play critical roles in governing brain function and cognition. Because NMDAR dysfunction contributes to the etiology of neurological and psychiatric disorders including stroke and schizophrenia, NMDAR modulators are potential drug candidates. Our group recently demonstrated that the major brain cholesterol metabolite, 24S-hydroxycholesterol (24S-HC), positively modulates NMDARs when exogenously administered. Here, we studied whether endogenous 24S-HC regulates NMDAR activity in hippocampal slices. In CYP46A1(-/-) (knockout; KO) slices where endogenous 24S-HC is greatly reduced, NMDAR tone, measured as NMDAR-to-α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor (AMPAR) excitatory postsynaptic current (EPSC) ratio, was reduced. This difference translated into more NMDAR-driven spiking in wild-type (WT) slices compared with KO slices. Application of SGE-301, a 24S-HC analog, had comparable potentiating effects on NMDAR EPSCs in both WT and KO slices, suggesting that endogenous 24S-HC does not saturate its NMDAR modulatory site in ex vivo slices. KO slices did not differ from WT slices in either spontaneous neurotransmission or in neuronal intrinsic excitability, and exhibited LTP indistinguishable from WT slices. However, KO slices exhibited higher resistance to persistent NMDAR-dependent depression of synaptic transmission induced by oxygen-glucose deprivation (OGD), an effect restored by SGE-301. Together, our results suggest that loss of positive NMDAR tone does not elicit compensatory changes in excitability or transmission, but it protects transmission against NMDAR-mediated dysfunction. We expect that manipulating this endogenous NMDAR modulator may offer new treatment strategies for neuropsychiatric dysfunction. Copyright © 2016 the American Physiological Society.

  6. Examination of the structure-toxicity relationships of L-cysteine-S-conjugates of halogenated alkenes and their corresponding mercapturic acids in rat renal tissue slices.

    NARCIS (Netherlands)

    Stijntjes, G.J.; Commandeur, J.N.M.; te Koppele, J.M.; McGuinness, S; Gandolfi, A.J.; Vermeulen, N.P.E.

    1993-01-01

    Rat kidney slices were produced using a modified version of a mechanical tissue slicer. The slices were incubated with various concentrations of l-cysteine conjugates and mercapturic acids of halogenated alkenes in a submersion incubation system. The slices showed a time- and concentration-dependent

  7. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  8. Generalized Fourier slice theorem for cone-beam image reconstruction.

    Science.gov (United States)

    Zhao, Shuang-Ren; Jiang, Dazong; Yang, Kevin; Yang, Kang

    2015-01-01

    The cone-beam reconstruction theory has been proposed by Kirillov in 1961, Tuy in 1983, Feldkamp in 1984, Smith in 1985, Pierre Grangeat in 1990. The Fourier slice theorem is proposed by Bracewell 1956, which leads to the Fourier image reconstruction method for parallel-beam geometry. The Fourier slice theorem is extended to fan-beam geometry by Zhao in 1993 and 1995. By combining the above mentioned cone-beam image reconstruction theory and the above mentioned Fourier slice theory of fan-beam geometry, the Fourier slice theorem in cone-beam geometry is proposed by Zhao 1995 in short conference publication. This article offers the details of the derivation and implementation of this Fourier slice theorem for cone-beam geometry. Especially the problem of the reconstruction from Fourier domain has been overcome, which is that the value of in the origin of Fourier space is 0/0. The 0/0 type of limit is proper handled. As examples, the implementation results for the single circle and two perpendicular circle source orbits are shown. In the cone-beam reconstruction if a interpolation process is considered, the number of the calculations for the generalized Fourier slice theorem algorithm is O(N^4), which is close to the filtered back-projection method, here N is the image size of 1-dimension. However the interpolation process can be avoid, in that case the number of the calculations is O(N5).

  9. Abscisic Acid accumulation in spinach leaf slices in the presence of penetrating and nonpenetrating solutes.

    Science.gov (United States)

    Creelman, R A; Zeevaart, J A

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation.When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO(3), 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage).

  10. Continuous Slice Functional Calculus in Quaternionic Hilbert Spaces

    Science.gov (United States)

    Ghiloni, Riccardo; Moretti, Valter; Perotti, Alessandro

    2013-04-01

    The aim of this work is to define a continuous functional calculus in quaternionic Hilbert spaces, starting from basic issues regarding the notion of spherical spectrum of a normal operator. As properties of the spherical spectrum suggest, the class of continuous functions to consider in this setting is the one of slice quaternionic functions. Slice functions generalize the concept of slice regular function, which comprises power series with quaternionic coefficients on one side and that can be seen as an effective generalization to quaternions of holomorphic functions of one complex variable. The notion of slice function allows to introduce suitable classes of real, complex and quaternionic C*-algebras and to define, on each of these C*-algebras, a functional calculus for quaternionic normal operators. In particular, we establish several versions of the spectral map theorem. Some of the results are proved also for unbounded operators. However, the mentioned continuous functional calculi are defined only for bounded normal operators. Some comments on the physical significance of our work are included.

  11. Solar magnetic field studies using the 12 micron emission lines. I - Quiet sun time series and sunspot slices

    Science.gov (United States)

    Deming, Drake; Boyle, Robert J.; Jennings, Donald E.; Wiedemann, Gunter

    1988-01-01

    The use of the extremely Zeeman-sensitive IR emission line Mg I, at 12.32 microns, to study solar magnetic fields. Time series observations of the line in the quiet sun were obtained in order to determine the response time of the line to the five-minute oscillations. Based upon the velocity amplitude and average period measured in the line, it is concluded that it is formed in the temperature minimum region. The magnetic structure of sunspots is investigated by stepping a small field of view in linear 'slices' through the spots. The region of penumbral line formation does not show the Evershed outflow common in photospheric lines. The line intensity is a factor of two greater in sunspot penumbrae than in the photosphere, and at the limb the penumbral emission begins to depart from optical thinness, the line source function increasing with height. For a spot near disk center, the radial decrease in absolute magnetic field strength is steeper than the generally accepted dependence.

  12. Thermoluminescence results on slices from a Hiroshima tile UHFSFT03

    International Nuclear Information System (INIS)

    Stoneham, Doreen

    1987-01-01

    As was reported at the May 1984 Utah thermoluminescence (TL) workshop, high fired tiles and porcelain fragments can be sliced into 200 μm sections with constant surface area. When conventional pre-dose measurements were carried out on these slices the doses evaluated were in good agreement with results obtained by other workers using conventional quartz separation techniques. There are several advantages in using slices. First, less sample is needed as about 50 consecutive slices can be cut from a block measuring typically 1 cm 2 cross section and 2 cm in length. There are no problems with securing grains to the plate or loss of grains during measurement. Hypothetically there is less damage to the grains when they are cut slowly under cold water than when they are crushed. The disadvantage is that other minerals besides quartz are present in the slice and the signal is weaker than that obtained using quartz inclusions

  13. Modeling and Realization of a Bearingless Flux-Switching Slice Motor

    Directory of Open Access Journals (Sweden)

    Wolfgang Gruber

    2017-03-01

    Full Text Available This work introduces a novel bearingless slice motor design: the bearingless flux-switching slice motor. In contrast to state-of-the-art bearingless slice motors, the rotor in this new design does not include any permanent rotor magnets. This offers advantages for disposable devices, such as those used in the medical industry, and extends the range of bearingless slice motors toward high-temperature applications. In this study, our focus is on the analytical modeling of the suspension force torque generation of a single coil and the bearingless motor. We assessed motor performance in relation to motor topology by applying performance factors. A prototype motor was optimized, designed, and manufactured. We also presented the state-of-the-art nonlinear feedback control scheme used. The motor was operated, and both static and dynamic measurements were taken on a test bench, thus successfully demonstrating the functionality and applicability of the novel bearingless slice motor concept.

  14. Design and Development of a tomato Slicing Machine

    OpenAIRE

    Kamaldeen Oladimeji Salaudeen; Awagu E. F.

    2012-01-01

    Principle of slicing was reviewed and tomato slicing machine was developed based on appropriate technology. Locally available materials like wood, stainless steel and mild steel were used in the fabrication. The machine was made to cut tomatoes in 2cm thickness. The capacity of the machine is 540.09g per minute and its performance efficiency is 70%.

  15. Sugar uptake and starch biosynthesis by slices of developing maize endosperm

    International Nuclear Information System (INIS)

    Felker, F.C.; Liu, Kangchien; Shannon, J.C.

    1990-01-01

    14 C-Sugar uptake and incorporation into starch by slices of developing maize (Zea mays L.) endosperm were examined and compared with sugar uptake by maize endosperm-derived suspension cultures. Rates of sucrose, fructose, and D- and L-glucose uptake by slices were similar, whereas uptake rates for these sugars differed greatly in suspension cultures. Concentration dependence of sucrose, fructose, and D-glucose uptake was biphasic (consisting of linear plus saturable components) with suspension cultures but linear with slices. These and other differences suggest that endosperm slices are freely permeable to sugars. After diffusion into the slices, sugars were metabolized and incorporated into starch. Starch synthesis, but not sugar accumulation, was greatly reduced by 2.5 millimolar p-chloromercuribenzenesulfonic acid and 0.1 millimolar carbonyl cyanide m-chlorophenylhydrazone. Starch synthesis was dependent on kernel age and incubation temperature, but not on external pH (5 through 8). Competing sugars generally did not affect the distribution of 14 C among the soluble sugars extracted from endosperm slices incubated in 14 C-sugars. Competing hexoses reduced the incorporation of 14 C into starch, but competing sucrose did not, suggesting that sucrose is not a necessary intermediate in starch biosynthesis. The bidirectional permeability of endosperm slices to sugars makes the characterization of sugar transport into endosperm slices impossible, however the model system is useful for experiments dealing with starch biosynthesis which occurs in the metabolically active tissue

  16. Real time simulation techniques in Taiwan - Maanshan compact simulator

    International Nuclear Information System (INIS)

    Liang, K.-S.; Chuang, Y.-M.; Ko, H.-T.

    2004-01-01

    Recognizing the demand and potential market of simulators in various industries, a special project for real time simulation technology transfer was initiated in Taiwan in 1991. In this technology transfer program, the most advanced real-time dynamic modules for nuclear power simulation were introduced. Those modules can be divided into two categories; one is modeling related to catch dynamic response of each system, and the other is computer related to provide special real time computing environment and man-machine interface. The modeling related modules consist of the thermodynamic module, the three-dimensional core neutronics module and the advanced balance of plant module. As planned in the project, the technology transfer team should build a compact simulator for the Maanshan power plant before the end of the project to demonstrate the success of the technology transfer program. The compact simulator was designed to support the training from the regular full scope simulator which was already equipped in the Maanshan plant. The feature of this compact simulator focused on providing know-why training by the enhanced graphic display. The potential users were identified as senior operators, instructors and nuclear engineers. Total about 13 important systems were covered in the scope of the compact simulator, and multi-graphic displays from three color monitors mounted on the 10 feet compact panel were facilitated to help the user visualize detailed phenomena under scenarios of interest. (author)

  17. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography

    International Nuclear Information System (INIS)

    Burgstahler, Christof; Reimann, Anja; Brodoefel, Harald; Tsiflikas, Ilias; Thomas, Christoph; Heuschmid, Martin; Daferner, Ulrike; Drosch, Tanja; Schroeder, Stephen; Herberts, Tina

    2009-01-01

    Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n=90; Siemens Sensation 64: n=91; Siemens Definition: n=75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347±13 vs. 254±14 (64-MSCT) vs. 233±11 (16-MSCT) HU], LM (362±11/275 ± 12/262±9), LAD (332±17/248±19/219±14) and LCX (310±12/210±13/221±10, all p<0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p<0.05). BMI had no impact on the CA ratio in DSCT only (p<0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a

  18. Effect of ultrasound and centrifugal force on carambola (Averrhoa carambola L.) slices during osmotic dehydration.

    Science.gov (United States)

    Barman, Nirmali; Badwaik, Laxmikant S

    2017-01-01

    Osmotic dehydration (OD) of carambola slices were carried out using glucose, sucrose, fructose and glycerol as osmotic agents with 70°Bx solute concentration, 50°C of temperature and for time of 180min. Glycerol and sucrose were selected on the basis of their higher water loss, weight reduction and lowers solid gain. Further the optimization of OD of carambola slices (5mm thick) were carried out under different process conditions of temperature (40-60°C), concentration of sucrose and glycerol (50-70°Bx), time (180min) and fruit to solution ratio (1:10) against various responses viz. water loss, solid gain, texture, rehydration ratio and sensory score according to a composite design. The optimized value for temperature, concentration of sucrose and glycerol has been found to be 50°C, 66°Bx and 66°Bx respectively. Under optimized conditions the effect of ultrasound for 10, 20, 30min and centrifugal force (2800rpm) for 15, 30, 45 and 60min on OD of carambola slices were checked. The controlled samples showed 68.14% water loss and 13.05% solid gain in carambola slices. While, the sample having 30min ultrasonic treatment showed 73.76% water loss and 9.79% solid gain; and the sample treated with centrifugal force for 60min showed 75.65% water loss and 6.76% solid gain. The results showed that with increasing in treatment time the water loss, rehydration ratio were increased and solid gain, texture were decreased. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Basic examination of in-plane spatial resolution in multi-slice CT

    International Nuclear Information System (INIS)

    Hara, Takanori; Kato, Hideki; Akiyama, Mitsutoshi; Murata, Katsutoshi

    2002-01-01

    In computed tomography (single-slice spiral CT, conventional CT), in-plane (x-y plane) spatial resolution is consistently identified as depending on the detector density of the in-plane (x-y plane). However, we considered that the in-plane (x-y plane) spatial resolution of multi-slice CT (MSCT) was influenced by an error in the detector's sensitivity to the Z-axis and by the frequency of use of direct row data and complementary row data when the image of spiral pitches (SP) was reconstructed. Our goal in this experiment was to analyze the relationship of the in-plane (x-y plane) spatial resolution of an asymmetric-type detector in MSCT to SP, tube current, and rotation time. By employing a tungsten wire phantom of 0.2 mm in diameter, we examined modulation transfer functions (MTF) by point-spread functions (PSF) of CT-images. Next, using the mean-square-root bandwidth theory, we analyzed the MTF of wire phantoms. The analysis of in-plane (x-y plane) spatial resolution revealed that various tube currents had no effect on the value of the mean-square-root bandwidth. However, rotation time and high spiral pitch did have an effect on mean-square-root bandwidth. Considering the results mentioned above, spiral pitch (z-axis reconstruction algorithm) had a slight effect on in-plane (x-y plane) spatial resolution of asymmetric-type detectors in MSCT. Accordingly, we proposed a new general view of VDDz (view/mm) in MSCT that considered view data density on the Z-axis according to spiral pitch (mm/rotation), rotation time (view/rotation), and slice collimation. (author)

  20. Neuropeptide processing in regional brain slices: Effect of conformation and sequence

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.W.; Bijl, W.A.; van Nispen, J.W.; Brendel, K.; Davis, T.P. (Univ. of Arizona, Tucson (USA))

    1990-05-01

    The central enzymatic stability of des-enkephalin-gamma-endorphin and its synthetic analogs (cycloN alpha 6, C delta 11)beta-endorphin-(6-17) and (Pro7, Lys(Ac)9)-beta-endorphin(6-17) was studied in vitro using a newly developed, regionally dissected rat brain slice, time course incubation procedure. Tissue slice viability was estimated as the ability of the brain slice to take up or release gamma-(3H)aminobutyric acid after high K+ stimulation. Results demonstrated stability of uptake/release up to 5 hr of incubation, suggesting tissue viability over this period. The estimated half-life of peptides based on the results obtained in our incubation protocol suggest that the peptides studied are metabolized at different rates in the individual brain regions tested. A good correlation exists between the high enzyme activity of neutral endopeptidase and the rapid degradation of des-enkephalin-gamma-endorphin and (cycloN alpha 6, C delata 11)beta-endorphin-(6-17) in caudate putamen. Proline substitution combined with lysine acetylation appears to improve resistance to enzymatic metabolism in caudate putamen and hypothalamus. However, cyclization of des-enkephalin-gamma-endorphin forming an amide bond between the alpha-NH2 of the N-terminal threonine and the gamma-COOH of glutamic acid did not improve peptide stability in any brain region tested. The present study has shown that the brain slice technique is a valid and unique approach to study neuropeptide metabolism in small, discrete regions of rat brain where peptides, peptidases and receptors are colocalized and that specific structural modifications can improve peptide stability.

  1. Methods to induce primary and secondary traumatic damage in organotypic hippocampal slice cultures.

    Science.gov (United States)

    Adamchik, Y; Frantseva, M V; Weisspapir, M; Carlen, P L; Perez Velazquez, J L

    2000-04-01

    Organotypic brain slice cultures have been used in a variety of studies on neurodegenerative processes [K.M. Abdel-Hamid, M. Tymianski, Mechanisms and effects of intracellular calcium buffering on neuronal survival in organotypic hippocampal cultures exposed to anoxia/aglycemia or to excitotoxins, J. Neurosci. 17, 1997, pp. 3538-3553; D.W. Newell, A. Barth, V. Papermaster, A.T. Malouf, Glutamate and non-glutamate receptor mediated toxicity caused by oxygen and glucose deprivation in organotypic hippocampal cultures, J. Neurosci. 15, 1995, pp. 7702-7711; J.L. Perez Velazquez, M.V. Frantseva, P.L. Carlen, In vitro ischemia promotes glutamate mediated free radical generation and intracellular calcium accumulation in pyramidal neurons of cultured hippocampal slices, J. Neurosci. 23, 1997, pp. 9085-9094; L. Stoppini, L.A. Buchs, D. Muller, A simple method for organotypic cultures of nervous tissue, J. Neurosci. Methods 37, 1991, pp. 173-182; R.C. Tasker, J.T. Coyle, J.J. Vornov, The regional vulnerability to hypoglycemia induced neurotoxicity in organotypic hippocampal culture: protection by early tetrodotoxin or delayed MK 801, J. Neurosci. 12, 1992, pp. 4298-4308.]. We describe two methods to induce traumatic cell damage in hippocampal organotypic cultures. Primary trauma injury was achieved by rolling a stainless steel cylinder (0.9 g) on the organotypic slices. Secondary injury was followed after dropping a weight (0.137 g) on a localised area of the organotypic slice, from a height of 2 mm. The time course and extent of cell death were determined by measuring the fluorescence of the viability indicator propidium iodide (PI) at several time points after the injury. The initial localised impact damage spread 24 and 67 h after injury, cell death being 25% and 54%, respectively, when slices were kept at 37 degrees C. To validate these methods as models to assess neuroprotective strategies, similar insults were applied to slices at relatively low temperatures (30

  2. Pyrethroid insecticides evoke neurotransmitter release from rabbit striatal slices

    International Nuclear Information System (INIS)

    Eells, J.T.; Dubocovich, M.L.

    1988-01-01

    The effects of the synthetic pyrethroid insecticide fenvalerate ([R,S]-alpha-cyano-3-phenoxybenzyl[R,S]-2-(4-chlorophenyl)-3- methylbutyrate) on neurotransmitter release in rabbit brain slices were investigated. Fenvalerate evoked a calcium-dependent release of [ 3 H]dopamine and [ 3 H]acetylcholine from rabbit striatal slices that was concentration-dependent and specific for the toxic stereoisomer of the insecticide. The release of [ 3 H]dopamine and [ 3 H]acetylcholine by fenvalerate was modulated by D2 dopamine receptor activation and antagonized completely by the sodium channel blocker, tetrodotoxin. These findings are consistent with an action of fenvalerate on the voltage-dependent sodium channels of the presynaptic membrane resulting in membrane depolarization, and the release of dopamine and acetylcholine by a calcium-dependent exocytotic process. In contrast to results obtained in striatal slices, fenvalerate did not elicit the release of [ 3 H]norepinephrine or [ 3 H]acetylcholine from rabbit hippocampal slices indicative of regional differences in sensitivity to type II pyrethroid actions

  3. Visual interrogation of gyrokinetic particle simulations

    International Nuclear Information System (INIS)

    Jones, Chad; Ma, K-L; Sanderson, Allen; Myers, Lee Roy Jr

    2007-01-01

    Gyrokinetic particle simulations are critical to the study of anomalous energy transport associated with plasma microturbulence in magnetic confinement fusion experiments. The simulations are conducted on massively parallel computers and produce large quantities of particles, variables, and time steps, thus presenting a formidable challenge to data analysis tasks. We present two new visualization techniques for scientists to improve their understanding of the time-varying, multivariate particle data. One technique allows scientists to examine correlations in multivariate particle data with tightly coupled views of the data in both physical space and variable space, and to visually identify and track features of interest. The second technique, built into SCIRun, allows scientists to perform range-based queries over a series of time slices and visualize the resulting particles using glyphs. The ability to navigate the multiple dimensions of the particle data, as well as query individual or a collection of particles, enables scientists to not only validate their simulations but also discover new phenomena in their data

  4. Evaluation of the precision-cut liver and lung slice systems for the study of induction of CYP1, epoxide hydrolase and glutathione S-transferase activities.

    Science.gov (United States)

    Pushparajah, Daphnee S; Umachandran, Meera; Plant, Kathryn E; Plant, Nick; Ioannides, Costas

    2007-02-28

    The principal objective was to ascertain whether precision-cut tissue slices can be used to evaluate the potential of chemicals to induce CYP1, epoxide hydrolase and glutathione S-transferase activities, all being important enzymes involved in the metabolism of polycyclic aromatic hydrocarbons. Precision-cut rat liver and lung slices were incubated with a range of benzo[a]pyrene concentrations for various time periods. A rise in the O-deethylation of ethoxyresorufin was seen in both liver and lung slices exposed to benzo[a]pyrene, which was accompanied by increased CYP1A apoprotein levels. Pulmonary CYP1B1 apoprotein levels and hepatic mRNA levels were similarly enhanced. Elevated epoxide hydrolase and glutathione S-transferase activities were also observed in liver slices following incubation for 24h; similarly, a rise in apoprotein levels of both enzymes was evident, peak levels occurring at the same time point. When mRNA levels were monitored, a rise in the levels of both enzymes was seen as early as 4h after incubation, but maximum levels were attained at 24 h. In lung slices, induction of epoxide hydrolase by benzo[a]pyrene was observed after a 24-h incubation, and at a concentration of 1 microM; a rise in apoprotein levels was seen at this time point. Glutathione S-transferase activity was not inducible in lung slices by benzo[a]pyrene but a modest increase was observed in hepatic slices. Collectively, these studies confirmed CYP1A induction in rat liver slices and established that CYP1B1 expression, and epoxide hydrolase and glutathione S-transferase activities are inducible in precision-cut tissue slices.

  5. Abscisic Acid Accumulation in Spinach Leaf Slices in the Presence of Penetrating and Nonpenetrating Solutes 1

    Science.gov (United States)

    Creelman, Robert A.; Zeevaart, Jan A. D.

    1985-01-01

    Abscisic acid (ABA) accumulated in detached, wilted leaves of spinach (Spinacia oleracea L. cv Savoy Hybrid 612) and reached a maximum level within 3 to 4 hours. The increase in ABA over that found in detached turgid leaves was approximately 10-fold. The effects of water stress could be mimicked by the use of thin slices of spinach leaves incubated in the presence of 0.6 molar mannitol, a compound which causes plasmolysis (loss of turgor). About equal amounts of ABA were found both in the leaf slices and in detached leaves, whereas 2 to 4 times more ABA accumulated in the medium than in the slices. When spinach leaf slices were incubated with ethylene glycol, a compound which rapidly penetrates the cell membrane causing a decrease in the osmotic potential of the tissue and only transient loss of turgor, no ABA accumulated. Ethylene glycol was not inhibitory with respect to ABA accumulation. Spinach leaf slices incubated in both ethylene glycol and mannitol had ABA levels similar to those found when slices were incubated with mannitol alone. Increases similar to those found with mannitol also occurred when Aquacide III, a highly purified form of polyethylene glycol, was used. Aquacide III causes cytorrhysis, a situation similar to that found in wilted leaves. Thus, it appears that loss of turgor is essential for ABA accumulation. When spinach leaf slices were incubated with solutes which are supposed to disturb membrane integrity (KHSO3, 2-propanol, or KCl) no increase in ABA was observed. These data indicate that, with respect to the accumulation of ABA, mannitol caused a physical stress (loss of turgor) rather than a chemical stress (membrane damage). PMID:16664022

  6. Integrated fMRI Preprocessing Framework Using Extended Kalman Filter for Estimation of Slice-Wise Motion

    Directory of Open Access Journals (Sweden)

    Basile Pinsard

    2018-04-01

    Full Text Available Functional MRI acquisition is sensitive to subjects' motion that cannot be fully constrained. Therefore, signal corrections have to be applied a posteriori in order to mitigate the complex interactions between changing tissue localization and magnetic fields, gradients and readouts. To circumvent current preprocessing strategies limitations, we developed an integrated method that correct motion and spatial low-frequency intensity fluctuations at the level of each slice in order to better fit the acquisition processes. The registration of single or multiple simultaneously acquired slices is achieved online by an Iterated Extended Kalman Filter, favoring the robust estimation of continuous motion, while an intensity bias field is non-parametrically fitted. The proposed extraction of gray-matter BOLD activity from the acquisition space to an anatomical group template space, taking into account distortions, better preserves fine-scale patterns of activity. Importantly, the proposed unified framework generalizes to high-resolution multi-slice techniques. When tested on simulated and real data the latter shows a reduction of motion explained variance and signal variability when compared to the conventional preprocessing approach. These improvements provide more stable patterns of activity, facilitating investigation of cerebral information representation in healthy and/or clinical populations where motion is known to impact fine-scale data.

  7. Evaluation of methylmercury biotransformation using rat liver slices

    Energy Technology Data Exchange (ETDEWEB)

    Yasutake, A. [Biochemistry Section, National Inst. for Minamata Disease, Minamata, Kumamoto (Japan); Hirayama, K. [Kumamoto University College of Medical Science, Kuhonji (Japan)

    2001-09-01

    To examine the demethylation reaction of methylmercury (MeHg) in rat liver, slices prepared from MeHg-treated rats were incubated in L-15 medium under 95% O{sub 2}/5% CO{sub 2} atmosphere. During the incubation, the amount of inorganic Hg in the slices markedly increased in a time-dependent manner, although the concentration of total Hg remained unchanged. Since the C-Hg bond in MeHg was demonstrated to be cleaved by the action of some reactive oxygen species, the effects on MeHg demethylation of several reagents that could modify reactive oxygen production were examined in the present system. Methylviologen was found to be an effective enhancer of the demethylation reaction with only a minor effect on lipid peroxidation. On the other hand, ferrous ion added to the medium showed no effect on demethylation in the presence or absence of methylviologen, although lipid peroxide levels were increased significantly by ferrous ion. Similarly, deferoxamine mesylate, which effectively suppressed the increase in lipid peroxide levels, also had no effect on demethylation. Furthermore, hydroxy radical scavengers, such as mannitol and dimethylsulfoxide, had no effect on inorganic Hg production. Rotenone, an inhibitor of complex I in the mitochondrial electron transport system, increased levels of both inorganic Hg and lipid peroxide. However, other inhibitors, such as antimycin A, myxothiazole and NaCN, significantly suppressed the demethylation reaction. Cell fractionation of the MeHg-treated rat liver revealed that the ratio of inorganic Hg to total Hg was highest in the mitochondrial fraction. Furthermore, superoxide anion could degrade MeHg in an organic solvent but not in water. These results suggested that the demethylation of MeHg by the liver slice would proceed with the aid of superoxide anion produced in the electron transfer system at the hydrophobic mitochondrial inner membrane. Furthermore, the involvement of hydroxy radicals, which have been demonstrated to be

  8. Initial experience with AcQsim CT simulator

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Gerber, Russell; Bosch, Walter R.; Harms, William; Matthews, John W.; Purdy, James A.; Perez, Carlos A.

    1995-01-01

    performed with the patient on a conventional simulator in which portal radiographs are compared against DRRs. Results: Several important issues have been identified that impact on clinical utilization of the CT simulator. Thin, finely spaced CT slices improve the DRR quality but potentially degrade the quality of cross sectional images used for image segmentation. Large data sets also increase the workload for anatomic image segmentation (contouring) and raise concerns regarding data storage and easy network access. Software for image segmentation has been significantly improved allowing rapid drawing of contours around tumor/target volumes and normal tissues and improved edit functions that allow interpolation, copying, and correction of contours. These tools have reduced the time for defining all the normal tissues and target volumes for some sites (e.g. prostate) to less than 30 minutes. Acquisition of this large volume CT data currently takes less than 30 minutes potentially reducing patient time in the simulation/planning process. Difficult simulations, such as mantle/periaortic and craniospinal fields that typically require multiple 2-3 hour simulation sessions, now take half as much time with the spiral CT scanner. Subsequent field reductions or secondary fields can be planned without the physical presence of the patient. A comparison of predicted isocenter shift coordinates and actual coordinates used for verification simulation showed that the average change in isocenter position was less than a few mm indicating that the verification process can likely be eliminated. Disadvantages of current device include limited CT ring size (70 cm) and reconstruction window (48 cm) which prevent universal application of technique to all patients. Conclusion: The AcQsim offers significant advantages over a conventional simulator in terms of patient compliance and fatigue, as well as departmental throughput. In virtual simulation, after the initial acquisition of CT data, the CT

  9. Single-slice epicardial fat area measurement. Do we need to measure the total epicardial fat volume?

    International Nuclear Information System (INIS)

    Oyama, Noriko; Goto, Daisuke; Ito, Yoichi M.

    2011-01-01

    The aim of this study was to assess a method for measuring epicardial fat volume (EFV) by means of a single-slice area measurement. We investigated the relation between a single-slice fat area measurement and total EFV. A series of 72 consecutive patients (ages 65±11 years; 36 men) who had undergone cardiac computed tomography (CT) on a 64-slice multidetector scanner with prospective electrocardiographic triggering were retrospectively reviewed. Pixels in the pericardium with a density range from -230 to -30 Hounsfield units were considered fat, giving the per-slice epicardial fat area (EFA). The EFV was estimated by the summation of EFAs multiplied by the slice thickness. We investigated the relation between total EFV and each EFA. EFAs measured at several anatomical landmarks - right pulmonary artery, origins of the left main coronary artery, right coronary artery, coronary sinus - all correlated with the EFV (r=0.77-0.92). The EFA at the LMCA level was highly reproducible and showed an excellent correlation with the EFV (r=0.92). The EFA is significantly correlated with the EFV. The EFA is a simple, quick method for representing the time-consuming EFV, which has been used as a predictive indicator of cardiovascular diseases. (author)

  10. Toward real-time regional earthquake simulation II: Real-time Online earthquake Simulation (ROS) of Taiwan earthquakes

    Science.gov (United States)

    Lee, Shiann-Jong; Liu, Qinya; Tromp, Jeroen; Komatitsch, Dimitri; Liang, Wen-Tzong; Huang, Bor-Shouh

    2014-06-01

    We developed a Real-time Online earthquake Simulation system (ROS) to simulate regional earthquakes in Taiwan. The ROS uses a centroid moment tensor solution of seismic events from a Real-time Moment Tensor monitoring system (RMT), which provides all the point source parameters including the event origin time, hypocentral location, moment magnitude and focal mechanism within 2 min after the occurrence of an earthquake. Then, all of the source parameters are automatically forwarded to the ROS to perform an earthquake simulation, which is based on a spectral-element method (SEM). A new island-wide, high resolution SEM mesh model is developed for the whole Taiwan in this study. We have improved SEM mesh quality by introducing a thin high-resolution mesh layer near the surface to accommodate steep and rapidly varying topography. The mesh for the shallow sedimentary basin is adjusted to reflect its complex geometry and sharp lateral velocity contrasts. The grid resolution at the surface is about 545 m, which is sufficient to resolve topography and tomography data for simulations accurate up to 1.0 Hz. The ROS is also an infrastructural service, making online earthquake simulation feasible. Users can conduct their own earthquake simulation by providing a set of source parameters through the ROS webpage. For visualization, a ShakeMovie and ShakeMap are produced during the simulation. The time needed for one event is roughly 3 min for a 70 s ground motion simulation. The ROS is operated online at the Institute of Earth Sciences, Academia Sinica (http://ros.earth.sinica.edu.tw/). Our long-term goal for the ROS system is to contribute to public earth science outreach and to realize seismic ground motion prediction in real-time.

  11. Resource slicing in virtual wireless networks: a survey

    OpenAIRE

    Richart, Matias; Baliosian De Lazzari, Javier Ernesto; Serrat Fernández, Juan; Gorricho Moreno, Juan Luis

    2016-01-01

    New architectural and design approaches for radio access networks have appeared with the introduction of network virtualization in the wireless domain. One of these approaches splits the wireless network infrastructure into isolated virtual slices under their own management, requirements, and characteristics. Despite the advances in wireless virtualization, there are still many open issues regarding the resource allocation and isolation of wireless slices. Because of the dynamics and share...

  12. Real-time quasi-3D tomographic reconstruction

    Science.gov (United States)

    Buurlage, Jan-Willem; Kohr, Holger; Palenstijn, Willem Jan; Joost Batenburg, K.

    2018-06-01

    Developments in acquisition technology and a growing need for time-resolved experiments pose great computational challenges in tomography. In addition, access to reconstructions in real time is a highly demanded feature but has so far been out of reach. We show that by exploiting the mathematical properties of filtered backprojection-type methods, having access to real-time reconstructions of arbitrarily oriented slices becomes feasible. Furthermore, we present , software for visualization and on-demand reconstruction of slices. A user of can interactively shift and rotate slices in a GUI, while the software updates the slice in real time. For certain use cases, the possibility to study arbitrarily oriented slices in real time directly from the measured data provides sufficient visual and quantitative insight. Two such applications are discussed in this article.

  13. Verification-Driven Slicing of UML/OCL Models

    DEFF Research Database (Denmark)

    Shaikh, Asadullah; Clarisó Viladrosa, Robert; Wiil, Uffe Kock

    2010-01-01

    computational complexity can limit their scalability. In this paper, we consider a specific static model (UML class diagrams annotated with unrestricted OCL constraints) and a specific property to verify (satisfiability, i.e., “is it possible to create objects without violating any constraint?”). Current...... approaches to this problem have an exponential worst-case runtime. We propose a technique to improve their scalability by partitioning the original model into submodels (slices) which can be verified independently and where irrelevant information has been abstracted. The definition of the slicing procedure...

  14. Slice through an LHC bending magnet

    CERN Multimedia

    Slice through an LHC superconducting dipole (bending) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. There are 1232 15m long dipole magnets in the LHC.

  15. Preparation of positional renal slices for study of cell-specific toxicity.

    Science.gov (United States)

    Ruegg, C E; Gandolfi, A J; Nagle, R B; Krumdieck, C L; Brendel, K

    1987-04-01

    To reduce structural complexity, rabbit kidneys were sliced perpendicular to their cortical-papillary axis to isolate four distinct cell groupings. This positional orientation allows identification of each renal cell type based on its location within the slice. A mechanical slicer was used to make several precision-cut slices rapidly from an oriented cylindrical core of renal tissue, with minimal tissue trauma. Slices were then submerged under a gently circulating oxygenated media in a fritted glass support system that maintains viability (intracellular K+/DNA ratio) and structural integrity (histology) for at least 30 h. A high dose of mercuric chloride (10(-3) M) was used to demonstrate the structural and biochemical changes of intoxicated slices. This method provides a controlled subchronic in vitro system for the study of the individual cell types involved in cell-specific renal toxicities and may also be a useful tool for addressing other pharmacological and physiological research questions.

  16. An overview of 5G network slicing architecture

    Science.gov (United States)

    Chen, Qiang; Wang, Xiaolei; Lv, Yingying

    2018-05-01

    With the development of mobile communication technology, the traditional single network model has been unable to meet the needs of users, and the demand for differentiated services is increasing. In order to solve this problem, the fifth generation of mobile communication technology came into being, and as one of the key technologies of 5G, network slice is the core technology of network virtualization and software defined network, enabling network slices to flexibly provide one or more network services according to users' needs[1]. Each slice can independently tailor the network functions according to the requirements of the business scene and the traffic model and manage the layout of the corresponding network resources, to improve the flexibility of network services and the utilization of resources, and enhance the robustness and reliability of the whole network [2].

  17. Generation of a bubbly universe - a quantitative assessment of the CfA slice

    International Nuclear Information System (INIS)

    Ostriker, J.P.; Strassler, M.J.

    1989-01-01

    A first attempt is made to calculate the properties of the matter distribution in a universe filled with overlapping bubbles produced by multiple explosions. Each spherical shell follows the cosmological Sedov-Taylor solution until it encounters another shell. Thereafter, mergers are allowed to occur in pairs on the basis of N-body results. At the final epoch, the matrix of overlapping shells is populated with 'galaxies' and the properties of slices through the numerically constructed cube compare well with CfA survey results for specified initial conditions. A statistic is found which measures the distance distribution from uniformly distributed points to the nearest galaxies on the projected plane which appears to provide a good measure of the bubbly character of the galaxy distribution. In a quantitative analysis of the CfA 'slice of the universe', a very good match is found between simulation and the real data for final average bubble radii of (13.5 + or - 1.5)/h Mpc with formal filling factor 1.0-1.5 or actual filling factor of 65-80 percent. 25 references

  18. [Method of radiotherapy planning for head and neck tumors using simulated CT images and radiographic data, developed at the Gustave Roussy Institute].

    Science.gov (United States)

    Bridier, A; Diaz, J C; Kafrouni, H; Leclerc, A; Barrois, M M; Rivet, P; Wibault, P; Bourhis, J; Eschwège, F

    2001-06-01

    The paper deals with the recent improvements introduced in the most usual method applied in the Institut Gustave Roussy radiotherapy department for obtaining the anatomical data of patients treated for head and neck tumors. For each of these patients, five to seven transverses slices and a lateral radiographic film are taken from a Mecaserto simulator-CT. The anatomical representation of the patient sagittal plane is carried out from the digitalisation of the radiographic film on a Vidar Vxr-12 Plus film scanner and integrated into the Dosigray dose calculation programme in order to be used as a support for the laying out of the dose distribution in reference to the treatment. The sagittal anatomical representation obtained from the radiographic film digitalisation is compared with the one resulting from the interpolation between a limited number of irregularly-spaced transverse slices taken on the simulator-CT. The method using the simulator-scanner transverse slices and the radiographic film digitalisation represents an interesting alternative for obtaining an anatomy simulation representative of the patient in hospitals where a scanner is not available full-time for the needs of the radiotherapy process.

  19. Electron slicing for the generation of tunable femtosecond soft x-ray pulses from a free electron laser and slice diagnostics

    Directory of Open Access Journals (Sweden)

    S. Di Mitri

    2013-04-01

    Full Text Available We present the experimental results of femtosecond slicing an ultrarelativistic, high brightness electron beam with a collimator. In contrast to some qualitative considerations reported in Phys. Rev. Lett. 92, 074801 (2004PRLTAO0031-900710.1103/PhysRevLett.92.074801, we first demonstrate that the collimation process preserves the slice beam quality, in agreement with our theoretical expectations, and that the collimation is compatible with the operation of a linear accelerator in terms of beam transport, radiation dose, and collimator heating. Accordingly, the collimated beam can be used for the generation of stable femtosecond soft x-ray pulses of tunable duration, from either a self-amplified spontaneous emission or an externally seeded free electron laser. The proposed method also turns out to be a more compact and cheaper solution for electron slice diagnostics than the commonly used radio frequency deflecting cavities and has minimal impact on the machine design.

  20. (Non)perturbative gravity, nonlocality, and nice slices

    International Nuclear Information System (INIS)

    Giddings, Steven B.

    2006-01-01

    Perturbative dynamics of gravity is investigated for high-energy scattering and in black hole backgrounds. In the latter case, a straightforward perturbative analysis fails, in a close parallel to the failure of the former when the impact parameter reaches the Schwarzschild radius. This suggests a flaw in a semiclassical description of physics on spatial slices that intersect both outgoing Hawking radiation and matter that has carried information into a black hole; such slices are instrumental in a general argument for black hole information loss. This indicates a possible role for the proposal that nonperturbative gravitational physics is intrinsically nonlocal

  1. The clinical efficacy of 1 mm-slice CT of the middle ear

    International Nuclear Information System (INIS)

    Noda, Kazuhiro; Noiri, Teruhisa; Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-01-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  2. The clinical efficacy of 1 mm-slice CT of the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Noda, Kazuhiro; Noiri, Teruhisa [Kawanishi Municipal Hospital, Hyogo (Japan); Doi, Katsumi; Koizuka, Izumi; Tanaka, Hisashi; Mishiro, Yasuo; Okumura, Shin-ichi; Kubo, Takeshi

    2000-02-01

    The efficacy of the preoperative 1 mm-slice CT for evaluating the condition of the ossicular chain and the facial canal was assessed. CT findings were compared with the operative findings of middle ears in 120 cases of chronic otitis media or cholesteatoma that underwent tympanoplasty. The reliability of 1 mm-slice CT in detecting any defect of the ossicular chain was much superior to those of 2 mm-slice CT previously reported, and the difference between them is essential for preoperative information. On the other hand, thinner slice than 1 mm may be unnecessary, especially in routine use. (author)

  3. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  4. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  5. Slice through an LHC focusing magnet

    CERN Multimedia

    Slice through an LHC superconducting quadrupole (focusing) magnet. The slice includes a cut through the magnet wiring (niobium titanium), the beampipe and the steel magnet yokes. Particle beams in the Large Hadron Collider (LHC) have the same energy as a high-speed train, squeezed ready for collision into a space narrower than a human hair. Huge forces are needed to control them. Dipole magnets (2 poles) are used to bend the paths of the protons around the 27 km ring. Quadrupole magnets (4 poles) focus the proton beams and squeeze them so that more particles collide when the beams’ paths cross. Bringing beams into collision requires a precision comparable to making two knitting needles collide, launched from either side of the Atlantic Ocean.

  6. Time step MOTA thermostat simulation

    International Nuclear Information System (INIS)

    Guthrie, G.L.

    1978-09-01

    The report details the logic, program layout, and operating procedures for the time-step MOTA (Materials Open Test Assembly) thermostat simulation program known as GYRD. It will enable prospective users to understand the operation of the program, run it, and interpret the results. The time-step simulation analysis was the approach chosen to determine the maximum value gain that could be used to minimize steady temperature offset without risking undamped thermal oscillations. The advantage of the GYRD program is that it directly shows hunting, ringing phenomenon, and similar events. Programs BITT and CYLB are faster, but do not directly show ringing time

  7. A Monte Carlo Simulation Framework for Testing Cosmological Models

    Directory of Open Access Journals (Sweden)

    Heymann Y.

    2014-10-01

    Full Text Available We tested alternative cosmologies using Monte Carlo simulations based on the sam- pling method of the zCosmos galactic survey. The survey encompasses a collection of observable galaxies with respective redshifts that have been obtained for a given spec- troscopic area of the sky. Using a cosmological model, we can convert the redshifts into light-travel times and, by slicing the survey into small redshift buckets, compute a curve of galactic density over time. Because foreground galaxies obstruct the images of more distant galaxies, we simulated the theoretical galactic density curve using an average galactic radius. By comparing the galactic density curves of the simulations with that of the survey, we could assess the cosmologies. We applied the test to the expanding-universe cosmology of de Sitter and to a dichotomous cosmology.

  8. Numerical simulations of time-resolved quantum electronics

    International Nuclear Information System (INIS)

    Gaury, Benoit; Weston, Joseph; Santin, Matthieu; Houzet, Manuel; Groth, Christoph; Waintal, Xavier

    2014-01-01

    Numerical simulation has become a major tool in quantum electronics both for fundamental and applied purposes. While for a long time those simulations focused on stationary properties (e.g. DC currents), the recent experimental trend toward GHz frequencies and beyond has triggered a new interest for handling time-dependent perturbations. As the experimental frequencies get higher, it becomes possible to conceive experiments which are both time-resolved and fast enough to probe the internal quantum dynamics of the system. This paper discusses the technical aspects–mathematical and numerical–associated with the numerical simulations of such a setup in the time domain (i.e. beyond the single-frequency AC limit). After a short review of the state of the art, we develop a theoretical framework for the calculation of time-resolved observables in a general multiterminal system subject to an arbitrary time-dependent perturbation (oscillating electrostatic gates, voltage pulses, time-varying magnetic fields, etc.) The approach is mathematically equivalent to (i) the time-dependent scattering formalism, (ii) the time-resolved non-equilibrium Green’s function (NEGF) formalism and (iii) the partition-free approach. The central object of our theory is a wave function that obeys a simple Schrödinger equation with an additional source term that accounts for the electrons injected from the electrodes. The time-resolved observables (current, density, etc.) and the (inelastic) scattering matrix are simply expressed in terms of this wave function. We use our approach to develop a numerical technique for simulating time-resolved quantum transport. We find that the use of this wave function is advantageous for numerical simulations resulting in a speed up of many orders of magnitude with respect to the direct integration of NEGF equations. Our technique allows one to simulate realistic situations beyond simple models, a subject that was until now beyond the simulation

  9. Excitatory and inhibitory pathways modulate kainate excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Casaccia-Bonnefil, P; Benedikz, Eirikur; Rai, R

    1993-01-01

    In organotypic hippocampal slice cultures, kainate (KA) specifically induces cell loss in the CA3 region while N-methyl-D-aspartate induces cell loss in the CA1 region. The sensitivity of slice cultures to KA toxicity appears only after 2 weeks in vitro which parallels the appearance of mossy...... fibers. KA toxicity is potentiated by co-application with the GABA-A antagonist, picrotoxin. These data suggest that the excitotoxicity of KA in slice cultures is modulated by both excitatory and inhibitory synapses....

  10. SU-E-J-66: Evaluation of a Real-Time Positioning Assistance Simulator System for Skull Radiography Using the Microsoft Kinect

    International Nuclear Information System (INIS)

    Kurata, T; Ono, M; Kozono, K; Fukuyoshi, R; Sato, S; Toyofuku, F

    2014-01-01

    Purpose: The purpose of this study is to investigate the feasibility of a low cost, small size positioning assistance simulator system for skull radiography using the Microsoft Kinect sensor. A conventional radiographic simulator system can only measure the three-dimensional coordinates of an x-ray tube using angle sensors, but not measure the movement of the subject. Therefore, in this study, we developed a real-time simulator system using the Microsoft Kinect to measure both the x-ray tube and the subject, and evaluated its accuracy and feasibility by comparing the simulated and the measured x-ray images. Methods: This system can track a head phantom by using Face Tracking, which is one of the functions of the Kinect. The relative relationship between the Kinect and the head phantom was measured and the projection image was calculated by using the ray casting method, and by using three-dimensional CT head data with 220 slices at 512 × 512 pixels. X-ray images were thus obtained by using a computed radiography (CR) system. We could then compare the simulated projection images with the measured x-ray images from 0 degrees to 45 degrees at increments of 15 degrees by calculating the cross correlation coefficient C. Results: The calculation time of the simulated projection images was almost real-time (within 1 second) by using the Graphics Processing Unit(GPU). The cross-correlation coefficients C are: 0.916; 0.909; 0.891; and, 0.886 at 0, 15, 30, and 45 degrees, respectively. As a result, there were strong correlations between the simulated and measured images. Conclusion: This system can be used to perform head positioning more easily and accurately. It is expected that this system will be useful for learning radiographic techniques by students. Moreover, it could also be used for predicting the actual x-ray image prior to x-ray exposure in clinical environments

  11. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  12. The visibility of mandibular canal on orthoradial and oblique CBCT slices at molar implant sites

    International Nuclear Information System (INIS)

    Alkhader, Mustafa; Jarab, Fadi; Shaweesh, Ashraf; Hudieb, Malik

    2016-01-01

    The aim of the present study was to compare visibility of the mandibular canal on cone beam computed tomography (CBCT)-based orthoradial and oblique slices at molar implant sites. CBCT images for 132 mandibular molar implant sites were selected for the study. After generating orthoradial and oblique slices, two observers evaluated the visibility of the mandibular canal using three-point scoring scale (1-3, good to excellent). Wilcoxon signed-rank test compared the visibility scores of the two slices. Both orthoradial and oblique slices obtained from CBCT had only very good to excellent mandibular canal visibility scores. At 114 mandibular molar implant sites, the visibility score was equal on both orthoradial and oblique slices. Although the visibility score was higher on orthoradial slices for 12 implant sites, the visibility score was higher for six implant sites on oblique slices and the difference was not significant. Therefore, the visibility of the mandibular canal was excellent and comparable on most of orthoradial and oblique slices obtained from CBCT images

  13. Slice image pretreatment for cone-beam computed tomography based on adaptive filter

    International Nuclear Information System (INIS)

    Huang Kuidong; Zhang Dinghua; Jin Yanfang

    2009-01-01

    According to the noise properties and the serial slice image characteristics in Cone-Beam Computed Tomography (CBCT) system, a slice image pretreatment for CBCT based on adaptive filter was proposed. The judging criterion for the noise is established firstly. All pixels are classified into two classes: adaptive center weighted modified trimmed mean (ACWMTM) filter is used for the pixels corrupted by Gauss noise and adaptive median (AM) filter is used for the pixels corrupted by impulse noise. In ACWMTM filtering algorithm, the estimated Gauss noise standard deviation in the current slice image with offset window is replaced by the estimated standard deviation in the adjacent slice image to the current with the corresponding window, so the filtering accuracy of the serial images is improved. The pretreatment experiment on CBCT slice images of wax model of hollow turbine blade shows that the method makes a good performance both on eliminating noises and on protecting details. (authors)

  14. Simulation of deep one- and two-dimensional redshift surveys

    International Nuclear Information System (INIS)

    Park, Changbom; Gott, J.R. III

    1991-01-01

    We show that slice or pencil-beam redshift surveys of galaxies can be simulated in a box with non-equal sides. This method saves a lot of computer time and memory while providing essentially the same results as from whole-cube simulations. A 2457.6-h -1 Mpc-long rod (out to a redshift z = 0.58 in two opposite directions) is simulated using the standard biased Cold Dark Matter model as an example to mimic the recent deep pencil-beam surveys by Broadhurst et al. The structures (spikes) we see in these simulated samples occur when the narrow pencil-beam pierces walls, filaments and clusters appearing randomly along the line-of-sight. We have applied a statistical test for goodness of fit to a periodic lattice to the observations and the simulations. (author)

  15. A shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy

    Science.gov (United States)

    Mitra, Jhimli; Srikantha, Abhilash; Sidibé, Désiré; Martí, Robert; Oliver, Arnau; Lladó, Xavier; Ghose, Soumya; Vilanova, Joan C.; Comet, Josep; Meriaudeau, Fabrice

    2012-02-01

    This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to perform an analysis based on shape and information theory to reach close enough to the actual MR slice as validated by experts. The Bhattacharyya distance is used to find point correspondences between shape-context representations of the prostate contours. Thereafter, Chi-square distance is used to find out those MR slices where the prostates closely match with that of the TRUS slice. Normalized Mutual Information (NMI) values of the TRUS slice with each of the axial MR slices are computed after rigid alignment and consecutively a strategic elimination based on a set of rules between the Chi-square distances and the NMI leads to the required MR slice. We validated our method for TRUS axial slices of 15 patients, of which 11 results matched at least one experts validation and the remaining 4 are at most one slice away from the expert validations.

  16. Brain slice on a chip: opportunities and challenges of applying microfluidic technology to intact tissues.

    Science.gov (United States)

    Huang, Yu; Williams, Justin C; Johnson, Stephen M

    2012-06-21

    Isolated brain tissue, especially brain slices, are valuable experimental tools for studying neuronal function at the network, cellular, synaptic, and single channel levels. Neuroscientists have refined the methods for preserving brain slice viability and function and converged on principles that strongly resemble the approach taken by engineers in developing microfluidic devices. With respect to brain slices, microfluidic technology may 1) overcome the traditional limitations of conventional interface and submerged slice chambers and improve oxygen/nutrient penetration into slices, 2) provide better spatiotemporal control over solution flow/drug delivery to specific slice regions, and 3) permit successful integration with modern optical and electrophysiological techniques. In this review, we highlight the unique advantages of microfluidic devices for in vitro brain slice research, describe recent advances in the integration of microfluidic devices with optical and electrophysiological instrumentation, and discuss clinical applications of microfluidic technology as applied to brain slices and other non-neuronal tissues. We hope that this review will serve as an interdisciplinary guide for both neuroscientists studying brain tissue in vitro and engineers as they further develop microfluidic chamber technology for neuroscience research.

  17. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  18. Extension of shelf-life of Chickoo slices using hurdle technology

    International Nuclear Information System (INIS)

    Shirodkar, S.; Behere, A.G.; Padwal-Desai, S.R.; Lele, S.S.; Pai, J.S.

    2001-01-01

    An attempt has been made to evolve a protocol to prepare shelf-stable high moisture chickoo slices using Hurdle Technology. The process is based on a slight reduction of water activity (0.98?0.94) by osmosis with a 70 deg Brix sucrose syrup, lowering of pH (5.75 to 4.46) by addition of citric acid, addition of KMS and then subjecting the resulting slices to different doses of gamma radiation ranging from 0.25-1 kGy. Radiation processed chickoo slices remained acceptable for 8 weeks at sub-room temperature (10 ± 2 degC) and for 3 weeks at ambient temperature (28 ± 2 degC) when evaluated by a taste-test panel. (author)

  19. Thin-Slice Perception Develops Slowly

    Science.gov (United States)

    Balas, Benjamin; Kanwisher, Nancy; Saxe, Rebecca

    2012-01-01

    Body language and facial gesture provide sufficient visual information to support high-level social inferences from "thin slices" of behavior. Given short movies of nonverbal behavior, adults make reliable judgments in a large number of tasks. Here we find that the high precision of adults' nonverbal social perception depends on the slow…

  20. A rapid and simple method for cryopreservation of human liver slices

    NARCIS (Netherlands)

    de Kanter, R; Olinga, Peter; Hof, I.H; de Jager, M.H; Verwillegen, W.A; Slooff, M.JH; Meijer, D.K F; Groothuis, Geny; Koster, H

    1. Precision-cut liver slices represent a suitable and convenient in vitro preparation for studying metabolism and toxicity mechanisms of drugs and toxic chemicals. Particularly in the case of human liver slices, cryopreservation would enable more efficient utilization of this scarce and irregularly

  1. An automated framework for NMR resonance assignment through simultaneous slice picking and spin system forming

    KAUST Repository

    Abbas, Ahmed

    2014-04-19

    Despite significant advances in automated nuclear magnetic resonance-based protein structure determination, the high numbers of false positives and false negatives among the peaks selected by fully automated methods remain a problem. These false positives and negatives impair the performance of resonance assignment methods. One of the main reasons for this problem is that the computational research community often considers peak picking and resonance assignment to be two separate problems, whereas spectroscopists use expert knowledge to pick peaks and assign their resonances at the same time. We propose a novel framework that simultaneously conducts slice picking and spin system forming, an essential step in resonance assignment. Our framework then employs a genetic algorithm, directed by both connectivity information and amino acid typing information from the spin systems, to assign the spin systems to residues. The inputs to our framework can be as few as two commonly used spectra, i.e., CBCA(CO)NH and HNCACB. Different from the existing peak picking and resonance assignment methods that treat peaks as the units, our method is based on \\'slices\\', which are one-dimensional vectors in three-dimensional spectra that correspond to certain (N, H) values. Experimental results on both benchmark simulated data sets and four real protein data sets demonstrate that our method significantly outperforms the state-of-the-art methods while using a less number of spectra than those methods. Our method is freely available at http://sfb.kaust.edu.sa/Pages/Software.aspx. © 2014 Springer Science+Business Media.

  2. Organotypic hippocampal slice cultures for studies of brain damage, neuroprotection and neurorepair

    DEFF Research Database (Denmark)

    Noraberg, Jens; Poulsen, Frantz Rom; Blaabjerg, Morten

    2005-01-01

    Slices of developing brain tissue can be grown for several weeks as so-called organotypic slice cultures. Here we summarize and review studies using hippocampal slice cultures to investigate mechanisms and treatment strategies for the neurodegenerative disorders like stroke (cerebral ischemia......), Alzheimer's disease (AD) and epilepsia. Studies of non-excitotoxic neurotoxic compounds and the experimental use of slice cultures in studies of HIV neurotoxicity, traumatic brain injury (TBI) and neurogenesis are included. For cerebral ischemia, experimental models with oxygen-glucose deprivation (OGD......) and exposure to glutamate receptor agonists (excitotoxins) are reviewed. For epilepsia, focus is on induction of seizures with effects on neuronal loss, axonal sprouting and neurogenesis. For Alzheimer's disease, the review centers on the use of beta-amyloid (Abeta) in different models, while the section...

  3. Lysosome stabilization in slices of rat liver when incubated with vitamin A excess

    International Nuclear Information System (INIS)

    Morre, D.M.; Morre, D.J.; Bowen, S.; Reutter, W.

    1986-01-01

    An organ culture of slices of livers from adult rats was used to study effect of vitamin A (all-trans retinol) on lysosome stability. Lysosomes were purified by centrifugation in Percoll gradients. Preparations were monitored by electron microscopy and evaluated by morphometry and assays of marker enzymes. Enrichments relative to homogenates and crude pellets were estimated from latent (triton X-100) acid p-nitrophenylphosphatase specific activities. Lysosomes prepared from unincubated slices were enriched 50-fold in latent acid phosphatase relative to homogenates. In contrast, lysosomes prepared from slices incubated for 30 min in PBS alone were enriched only 20-fold. When 25 μg/ml retinol was included in the incubation medium, enrichments of 40-fold were obtained. The integrity of the slices was monitored by electron microscopy and their viability was confirmed by a sustained uptake and incorporation of [ 3 H]leucine into protein (up to 2 h in culture). The loss of lysosomes from homogenates of slices incubated in the absence of retinol was accompanied by a loss of acid phosphatase from the lysosomal pellet to the supernatant during purification. Addition of retinol to slices just prior to homogenization was without effect. The results demonstrate a stabilizing influence of vitamin A on lysosomes during incubation of licer slices. The findings contrast earlier reports of retinol-induced lysosome fragility in other in vitro systems

  4. Maximal slicing of D-dimensional spherically symmetric vacuum spacetime

    International Nuclear Information System (INIS)

    Nakao, Ken-ichi; Abe, Hiroyuki; Yoshino, Hirotaka; Shibata, Masaru

    2009-01-01

    We study the foliation of a D-dimensional spherically symmetric black-hole spacetime with D≥5 by two kinds of one-parameter families of maximal hypersurfaces: a reflection-symmetric foliation with respect to the wormhole slot and a stationary foliation that has an infinitely long trumpetlike shape. As in the four-dimensional case, the foliations by the maximal hypersurfaces avoid the singularity irrespective of the dimensionality. This indicates that the maximal slicing condition will be useful for simulating higher-dimensional black-hole spacetimes in numerical relativity. For the case of D=5, we present analytic solutions of the intrinsic metric, the extrinsic curvature, the lapse function, and the shift vector for the foliation by the stationary maximal hypersurfaces. These data will be useful for checking five-dimensional numerical-relativity codes based on the moving puncture approach.

  5. Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.

    Science.gov (United States)

    Yeo, Desmond T B; Fessler, Jeffrey A; Kim, Boklye

    2008-06-01

    The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventionally, geometric distortion is "corrected" with a static field map independently of image registration. That approach ignores all field map changes induced by head motion. This work evaluates the improved motion correction capability of mapping slice to volume with concurrent iterative field corrected reconstruction using updated field maps derived from an initial static field map that has been spatially transformed and resampled. It accounts for motion-induced field map changes for translational and in-plane rotation motion. The results from simulated EPI time series data, in which motion, image intensity and activation ground truths are available, show improved accuracy in image registration, field corrected image reconstruction and activation detection.

  6. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT

    International Nuclear Information System (INIS)

    Kloeppel, R.; Kahn, T.; Schreiter, D.; Dietrich, J.; Josten, C.

    2002-01-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of ∼30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by ∼4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [de

  7. Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in EPI

    Science.gov (United States)

    Yeo, Desmond T. B.; Fessler, Jeffrey A.; Kim, Boklye

    2014-01-01

    The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data is severely degraded in the presence of head motion. In addition, EPI is sensitive to susceptibility-induced geometric distortions. Head motion causes image shifts and associated field map changes that induce different geometric distortion at different time points. Conventionally, geometric distortion is “corrected” with a static field map independently of image registration. That approach ignores all field map changes induced by head motion. This work evaluates the improved motion correction capability of mapping slice to volume (MSV) registration with concurrent iterative field corrected reconstruction using updated field maps derived from an initial static field map that has been spatially transformed and resampled. It accounts for motion-induced field map changes for translational and in-plane rotation motion. The results from simulated EPI time series data, in which motion, image intensity and activation ground truths are available, show improved accuracy in image registration, field corrected image reconstruction and activation detection. PMID:18280077

  8. Thin slices and Sherlock Holmes

    African Journals Online (AJOL)

    based on very little information, and often in a matter of seconds. This is partly based on very narrow slices of our experience, and involves pattern recognition, as well as the memory banks of our senses. It is also partly a heuristic process whereby one rapidly discards ideas or notions, or promotes other hypotheses, as one.

  9. On the generation of a bubbly universe - A quantitative assessment of the CfA slice

    Science.gov (United States)

    Ostriker, J. P.; Strassler, M. J.

    1989-01-01

    A first attempt is made to calculate the properties of the matter distribution in a universe filled with overlapping bubbles produced by multiple explosions. Each spherical shell follows the cosmological Sedov-Taylor solution until it encounters another shell. Thereafter, mergers are allowed to occur in pairs on the basis of N-body results. At the final epoch, the matrix of overlapping shells is populated with 'galaxies' and the properties of slices through the numerically constructed cube compare well with CfA survey results for specified initial conditions. A statistic is found which measures the distance distribution from uniformly distributed points to the nearest galaxies on the projected plane which appears to provide a good measure of the bubbly character of the galaxy distribution. In a quantitative analysis of the CfA 'slice of the universe', a very good match is found between simulation and the real data for final average bubble radii of (13.5 + or - 1.5)/h Mpc with formal filling factor 1.0-1.5 or actual filling factor of 65-80 percent.

  10. Accuracy of lung nodule density on HRCT: analysis by PSF-based image simulation.

    Science.gov (United States)

    Ohno, Ken; Ohkubo, Masaki; Marasinghe, Janaka C; Murao, Kohei; Matsumoto, Toru; Wada, Shinichi

    2012-11-08

    A computed tomography (CT) image simulation technique based on the point spread function (PSF) was applied to analyze the accuracy of CT-based clinical evaluations of lung nodule density. The PSF of the CT system was measured and used to perform the lung nodule image simulation. Then, the simulated image was resampled at intervals equal to the pixel size and the slice interval found in clinical high-resolution CT (HRCT) images. On those images, the nodule density was measured by placing a region of interest (ROI) commonly used for routine clinical practice, and comparing the measured value with the true value (a known density of object function used in the image simulation). It was quantitatively determined that the measured nodule density depended on the nodule diameter and the image reconstruction parameters (kernel and slice thickness). In addition, the measured density fluctuated, depending on the offset between the nodule center and the image voxel center. This fluctuation was reduced by decreasing the slice interval (i.e., with the use of overlapping reconstruction), leading to a stable density evaluation. Our proposed method of PSF-based image simulation accompanied with resampling enables a quantitative analysis of the accuracy of CT-based evaluations of lung nodule density. These results could potentially reveal clinical misreadings in diagnosis, and lead to more accurate and precise density evaluations. They would also be of value for determining the optimum scan and reconstruction parameters, such as image reconstruction kernels and slice thicknesses/intervals.

  11. SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C; Han, M; Baek, J [Yonsei University, Incheon (Korea, Republic of)

    2015-06-15

    Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photons per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR{sup 2} ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201

  12. SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

    International Nuclear Information System (INIS)

    Lee, C; Han, M; Baek, J

    2015-01-01

    Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photons per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR 2 ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201

  13. Modelling glioblastoma tumour-host cell interactions using adult brain organotypic slice co-culture

    Directory of Open Access Journals (Sweden)

    Maria Angeles Marques-Torrejon

    2018-02-01

    Full Text Available Glioblastoma multiforme (GBM is an aggressive incurable brain cancer. The cells that fuel the growth of tumours resemble neural stem cells found in the developing and adult mammalian forebrain. These are referred to as glioma stem cells (GSCs. Similar to neural stem cells, GSCs exhibit a variety of phenotypic states: dormant, quiescent, proliferative and differentiating. How environmental cues within the brain influence these distinct states is not well understood. Laboratory models of GBM can be generated using either genetically engineered mouse models, or via intracranial transplantation of cultured tumour initiating cells (mouse or human. Unfortunately, these approaches are expensive, time-consuming, low-throughput and ill-suited for monitoring live cell behaviours. Here, we explored whole adult brain coronal organotypic slices as an alternative model. Mouse adult brain slices remain viable in a serum-free basal medium for several weeks. GSCs can be easily microinjected into specific anatomical sites ex vivo, and we demonstrate distinct responses of engrafted GSCs to diverse microenvironments in the brain tissue. Within the subependymal zone – one of the adult neural stem cell niches – injected tumour cells could effectively engraft and respond to endothelial niche signals. Tumour-transplanted slices were treated with the antimitotic drug temozolomide as proof of principle of the utility in modelling responses to existing treatments. Engraftment of mouse or human GSCs onto whole brain coronal organotypic brain slices therefore provides a simplified, yet flexible, experimental model. This will help to increase the precision and throughput of modelling GSC-host brain interactions and complements ongoing in vivo studies. This article has an associated First Person interview with the first author of the paper.

  14. High performance real-time flight simulation at NASA Langley

    Science.gov (United States)

    Cleveland, Jeff I., II

    1994-01-01

    In order to meet the stringent time-critical requirements for real-time man-in-the-loop flight simulation, computer processing operations must be deterministic and be completed in as short a time as possible. This includes simulation mathematical model computational and data input/output to the simulators. In 1986, in response to increased demands for flight simulation performance, personnel at NASA's Langley Research Center (LaRC), working with the contractor, developed extensions to a standard input/output system to provide for high bandwidth, low latency data acquisition and distribution. The Computer Automated Measurement and Control technology (IEEE standard 595) was extended to meet the performance requirements for real-time simulation. This technology extension increased the effective bandwidth by a factor of ten and increased the performance of modules necessary for simulator communications. This technology is being used by more than 80 leading technological developers in the United States, Canada, and Europe. Included among the commercial applications of this technology are nuclear process control, power grid analysis, process monitoring, real-time simulation, and radar data acquisition. Personnel at LaRC have completed the development of the use of supercomputers for simulation mathematical model computational to support real-time flight simulation. This includes the development of a real-time operating system and the development of specialized software and hardware for the CAMAC simulator network. This work, coupled with the use of an open systems software architecture, has advanced the state of the art in real time flight simulation. The data acquisition technology innovation and experience with recent developments in this technology are described.

  15. Immature rat brain slices exposed to oxygen-glucose deprivation as an in vitro model of neonatal hypoxic-ischemic encephalopathy.

    Science.gov (United States)

    Fernández-López, David; Martínez-Orgado, José; Casanova, Ignacio; Bonet, Bartolomé; Leza, Juan Carlos; Lorenzo, Pedro; Moro, Maria Angeles; Lizasoain, Ignacio

    2005-06-30

    To analyze whether exposure to oxygen-glucose deprivation (OGD) of immature rat brain slices might reproduce the main pathophysiologic events leading to neuronal death in neonatal hypoxic-ischemic encephalopathy (NHIE), 500 microm-thick brain slices were obtained from 7-day-old Wistar rats, and incubated in oxygenated physiological solution. In OGD group, oxygen and glucose were removed from the medium for 10-30 min (n = 25); then, slices were re-incubated in normal medium. In control group the medium composition remained unchanged (CG, n = 30). Medium samples were obtained every 30 min for 3 h. To analyze neuronal damage, slices were stained with Nissl and CA1 area of hippocampus and cortex were observed under microscopy. In addition, neuronal death was quantified as LDH released to the medium determined by spectrophotometry. Additionally, medium glutamate (Glu) levels were determined by HPLC and those of TNFalpha by ELISA, whereas inducible nitric oxide synthase expression was determined by Western blot performed on slices homogenate. Optimal OGD time was established in 20 min. After OGD, a significant decrease in the number of neurones in hippocampus and cortex was observed. LDH release was maximal at 30 min, when it was five-fold greater than in CG. Furthermore, medium Glu concentrations were 200 times greater than CG levels at the end of OGD period. A linear relationship between Glu and LDH release was demonstrated. Finally, 3 h after OGD a significant induction of iNOS as well as an increase in TNFalpha release were observed. In conclusion, OGD appears as a feasible and reproducible in vitro model, leading to a neuronal damage, which is physiopathologically similar to that found in NHIE.

  16. Changes in Levels of Phenylethanoid Glycosides, Antioxidant Activity, and Other Quality Traits in Cistanche deserticola Slices by Steam Processing.

    Science.gov (United States)

    Peng, Fang; Chen, Jun; Wang, Xia; Xu, Changqing; Liu, Tongning; Xu, Rong

    2016-07-01

    We investigated the effect of steaming time on Cistanche deserticola Y. C. MA slices by analyzing levels of bioactive compounds, antioxidant activity, and weight loss compared with fresh, directly oven-dried, and blanched samples. Fresh samples had extremely low levels of phenylethanoid glycosides and antioxidant activity. Lower levels of weight loss and higher amounts of soluble sugars, polysaccharides, and dilute ethanol-soluble extracts were found when the slices were steamed rather than blanched. Slices steamed for 5 and 7 min contained significantly (pprocess. The concentration of polysaccharides fluctuated during the steaming process. The steaming time had a consistent effect on antioxidant properties evaluated by oxygen radical absorbance capacity (ORAC), 2,2-diphenyl-1-picrylhydrazyl free radical scavenging activity (DPPH) and ferric reducing antioxidant property (FRAP), showing a significant increase and reaching 108.62, 23.08, and 11.68 micromoles Trolox per mass of fresh slice (μmol TE/g FW), respectively. The present results suggest that fresh-cut C. deserticola can be subjected to approximately 5-7 min of steaming to improve phenylethanoid glycoside levels and antioxidant activity, while still preserving the amounts of soluble sugars, polysaccharides, and dilute ethanol-soluble extracts. These results would help to improve the production process for fresh-cut Chinese medicines, and increase the understanding of their associated health benefits.

  17. Turbulent stress measurements with phase-contrast magnetic resonance through tilted slices

    Energy Technology Data Exchange (ETDEWEB)

    MacKenzie, Jordan; Soederberg, Daniel; Lundell, Fredrik [Linne FLOW Centre, KTH Mechanics, Stockholm (Sweden); Swerin, Agne [SP Technical Research Institute of Sweden-Chemistry, Materials and Surfaces, Stockholm (Sweden); KTH Royal Institute of Technology, Surface and Corrosion Science, Stockholm (Sweden)

    2017-05-15

    Aiming at turbulent measurements in opaque suspensions, a simplistic methodology for measuring the turbulent stresses with phase-contrast magnetic resonance velocimetry is described. The method relies on flow-compensated and flow-encoding protocols with the flow encoding gradient normal to the slice. The experimental data is compared with direct numerical simulations (DNS), both directly but also, more importantly, after spatial averaging of the DNS data that resembles the measurement and data treatment of the experimental data. The results show that the most important MRI data (streamwise velocity, streamwise variance and Reynolds shear stress) is reliable up to at least anti r = 0.75 without any correction, paving the way for dearly needed turbulence and stress measurements in opaque suspensions. (orig.)

  18. Development of an electrically operated cassava slicing machine

    Directory of Open Access Journals (Sweden)

    I. S. Aji

    2013-08-01

    Full Text Available Labor input in manual cassava chips processing is very high and product quality is low. This paper presents the design and construction of an electrically operated cassava slicing machine that requires only one person to operate. Efficiency, portability, ease of operation, corrosion prevention of slicing component of the machine, force required to slice a cassava tuber, capacity of 10 kg/min and uniformity in the size of the cassava chips were considered in the design and fabrication of the machine. The performance of the machine was evaluated with cassava of average length and diameter of 253 mm and 60 mm respectively at an average speed of 154 rpm. The machine produced 5.3 kg of chips of 10 mm length and 60 mm diameter in 1 minute. The efficiency of the machine was 95.6% with respect to the quantity of the input cassava. The chips were found to be well chipped to the designed thickness, shape and of generally similar size. Galvanized steel sheets were used in the cutting section to avoid corrosion of components. The machine is portable and easy to operate which can be adopted for cassava processing in a medium size industry.

  19. Novel culturing platform for brain slices and neuronal cells

    DEFF Research Database (Denmark)

    Svendsen, Winnie Edith; Al Atraktchi, Fatima Al-Zahraa; Bakmand, Tanya

    2015-01-01

    In this paper we demonstrate a novel culturing system for brain slices and neuronal cells, which can control the concentration of nutrients and the waste removal from the culture by adjusting the fluid flow within the device. The entire system can be placed in an incubator. The system has been...... tested successfully with brain slices and PC12 cells. The culture substrate can be modified using metal electrodes and/or nanostructures for conducting electrical measurements while culturing and for better mimicking the in vivo conditions....

  20. Time Domain Partitioning of Electricity Production Cost Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Barrows, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hummon, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jones, W. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hale, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-01-01

    Production cost models are often used for planning by simulating power system operations over long time horizons. The simulation of a day-ahead energy market can take several weeks to compute. Tractability improvements are often made through model simplifications, such as: reductions in transmission modeling detail, relaxation of commitment variable integrality, reductions in cost modeling detail, etc. One common simplification is to partition the simulation horizon so that weekly or monthly horizons can be simulated in parallel. However, horizon partitions are often executed with overlap periods of arbitrary and sometimes zero length. We calculate the time domain persistence of historical unit commitment decisions to inform time domain partitioning of production cost models. The results are implemented using PLEXOS production cost modeling software in an HPC environment to improve the computation time of simulations while maintaining solution integrity.

  1. Multi-slice Fractional Ventilation Imaging in Large Animals with Hyperpolarized Gas MRI

    Science.gov (United States)

    Emami, Kiarash; Xu, Yinan; Hamedani, Hooman; Xin, Yi; Profka, Harrilla; Rajaei, Jennia; Kadlecek, Stephen; Ishii, Masaru; Rizi, Rahim R.

    2012-01-01

    Noninvasive assessment of regional lung ventilation is of critical importance in quantifying the severity of disease and evaluating response to therapy in many pulmonary diseases. This work presents for the first time the implementation of a hyperpolarized (HP) gas MRI technique for measuring whole-lung regional fractional ventilation (r) in Yorkshire pigs (n = 5) through the use of a gas mixing and delivery device in supine position. The proposed technique utilizes a series of back-to-back HP gas breaths with images acquired during short end-inspiratory breath-holds. In order to decouple the RF pulse decay effect from ventilatory signal build-up in the airways, regional distribution of flip angle (α) was estimated in the imaged slices by acquiring a series of back-to-back images with no inter-scan time delay during a breath-hold at the tail-end of the ventilation sequence. Analysis was performed to assess the multi-slice ventilation model sensitivity to noise, oxygen and number of flip angle images. The optimal α value was determined based on minimizing the error in r estimation; αopt = 5–6° for the set of acquisition parameters in pigs. The mean r values for the group of pigs were 0.27±0.09, 0.35±0.06, 0.40±0.04 for ventral, middle and dorsal slices, respectively, (excluding conductive airways r > 0.9). A positive gravitational (ventral-dorsal) ventilation gradient effect was present in all animals. The trachea and major conductive airways showed a uniform near-unity r value, with progressively smaller values corresponding to smaller diameter airways, and ultimately leading to lung parenchyma. Results demonstrate the feasibility of measurements of fractional ventilation in large species, and provides a platform to address technical challenges associated with long breathing time scales through the optimization of acquisition parameters in species with a pulmonary physiology very similar to that of human beings. PMID:22290603

  2. Real-time simulation of large-scale floods

    Science.gov (United States)

    Liu, Q.; Qin, Y.; Li, G. D.; Liu, Z.; Cheng, D. J.; Zhao, Y. H.

    2016-08-01

    According to the complex real-time water situation, the real-time simulation of large-scale floods is very important for flood prevention practice. Model robustness and running efficiency are two critical factors in successful real-time flood simulation. This paper proposed a robust, two-dimensional, shallow water model based on the unstructured Godunov- type finite volume method. A robust wet/dry front method is used to enhance the numerical stability. An adaptive method is proposed to improve the running efficiency. The proposed model is used for large-scale flood simulation on real topography. Results compared to those of MIKE21 show the strong performance of the proposed model.

  3. Geoelectric study in attempt to detect of deformation around slice gate in the embankment; Hiteiko eizoho wo mochiita himon shuhen no yurumi ryoiki no suitei

    Energy Technology Data Exchange (ETDEWEB)

    Natori, T; Nakayama, Y [Hokkaido Sapporo Public Works Office, Sapporo (Japan); Hashimoto, Y; Matsuo, J [OYO Corp., Tokyo (Japan)

    1997-10-22

    For the river structures, such as slice gates and slice pipes, constructed on the weak ground, structures often come out due to forced settlement of embankment, which results in the formation of cavity and loose ground. These deformations can cause disasters due to leakage by water channel and fracture of bank. It is significant to detect and grasp these situations in early stage. In this study, resistivity imaging was conducted around slice gate in several times, to estimate the loose region based on the difference in the obtained resistivity data. Resistivity was measured in two times with a certain interval using the same line. The loose region around the slice gate was estimated from the change of saturation condition and the saturation line by considering the difference. Even in the case when judgment was hard by a single measurement, it was possible to estimate the loose region based on the difference from multiple measurements. 3 refs., 6 figs.

  4. A fourth gradient to overcome slice dependent phase effects of voxel-sized coils in planar arrays.

    Science.gov (United States)

    Bosshard, John C; Eigenbrodt, Edwin P; McDougall, Mary P; Wright, Steven M

    2010-01-01

    The signals from an array of densely spaced long and narrow receive coils for MRI are complicated when the voxel size is of comparable dimension to the coil size. The RF coil causes a phase gradient across each voxel, which is dependent on the distance from the coil, resulting in a slice dependent shift of k-space. A fourth gradient coil has been implemented and used with the system's gradient set to create a gradient field which varies with slice. The gradients are pulsed together to impart a slice dependent phase gradient to compensate for the slice dependent phase due to the RF coils. However the non-linearity in the fourth gradient which creates the desired slice dependency also results in a through-slice phase ramp, which disturbs normal slice refocusing and leads to additional signal cancelation and reduced field of view. This paper discusses the benefits and limitations of using a fourth gradient coil to compensate for the phase due to RF coils.

  5. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  6. Flat synchronizations in spherically symmetric space-times

    International Nuclear Information System (INIS)

    Herrero, Alicia; Morales-Lladosa, Juan Antonio

    2010-01-01

    It is well known that the Schwarzschild space-time admits a spacelike slicing by flat instants and that the metric is regular at the horizon in the associated adapted coordinates (Painleve-Gullstrand metric form). We consider this type of flat slicings in an arbitrary spherically symmetric space-time. The condition ensuring its existence is analyzed, and then, we prove that, for any spherically symmetric flat slicing, the densities of the Weinberg momenta vanish. Finally, we deduce the Schwarzschild solution in the extended Painleve-Gullstrand-LemaItre metric form by considering the coordinate decomposition of the vacuum Einstein equations with respect to a flat spacelike slicing.

  7. Numerical simulation and comparison of nonlinear self-focusing based on iteration and ray tracing

    Science.gov (United States)

    Li, Xiaotong; Chen, Hao; Wang, Weiwei; Ruan, Wangchao; Zhang, Luwei; Cen, Zhaofeng

    2017-05-01

    Self-focusing is observed in nonlinear materials owing to the interaction between laser and matter when laser beam propagates. Some of numerical simulation strategies such as the beam propagation method (BPM) based on nonlinear Schrödinger equation and ray tracing method based on Fermat's principle have applied to simulate the self-focusing process. In this paper we present an iteration nonlinear ray tracing method in that the nonlinear material is also cut into massive slices just like the existing approaches, but instead of paraxial approximation and split-step Fourier transform, a large quantity of sampled real rays are traced step by step through the system with changing refractive index and laser intensity by iteration. In this process a smooth treatment is employed to generate a laser density distribution at each slice to decrease the error caused by the under-sampling. The characteristics of this method is that the nonlinear refractive indices of the points on current slice are calculated by iteration so as to solve the problem of unknown parameters in the material caused by the causal relationship between laser intensity and nonlinear refractive index. Compared with the beam propagation method, this algorithm is more suitable for engineering application with lower time complexity, and has the calculation capacity for numerical simulation of self-focusing process in the systems including both of linear and nonlinear optical media. If the sampled rays are traced with their complex amplitudes and light paths or phases, it will be possible to simulate the superposition effects of different beam. At the end of the paper, the advantages and disadvantages of this algorithm are discussed.

  8. Difference in Uptake of Tetrodotoxin and Saxitoxins into Liver Tissue Slices among Pufferfish, Boxfish and Porcupinefish

    Directory of Open Access Journals (Sweden)

    Yuji Nagashima

    2018-01-01

    Full Text Available Although pufferfish of the family Tetraodontidae contain high levels of tetrodotoxin (TTX mainly in the liver, some species of pufferfish, boxfish of the family Ostraciidae, and porcupinefish of the family Diodontidae do not. To clarify the mechanisms, uptake of TTX and saxitoxins (STXs into liver tissue slices of pufferfish, boxfish and porcupinefish was examined. Liver tissue slices of the pufferfish (toxic species Takifugu rubripes and non-toxic species Lagocephalus spadiceus, L. cheesemanii and Sphoeroides pachygaster incubated with 50 µM TTX accumulated TTX (0.99–1.55 µg TTX/mg protein after 8 h, regardless of the toxicity of the species. In contrast, in liver tissue slices of boxfish (Ostracion immaculatus and porcupinefish (Diodon holocanthus, D. liturosus, D. hystrix and Chilomycterus reticulatus, TTX content did not increase with incubation time, and was about 0.1 µg TTX/mg protein. When liver tissue slices were incubated with 50 µM STXs for 8 h, the STXs content was <0.1 µg STXs/mg protein, irrespective of the fish species. These findings indicate that, like the toxic species of pufferfish T. rubripes, non-toxic species such as L. spadiceus, L. cheesemanii and S. pachygaster, potentially take up TTX into the liver, while non-toxic boxfish and porcupinefish do not take up either TTX or STXs.

  9. Real-Time-Simulation of IEEE-5-Bus Network on OPAL-RT-OP4510 Simulator

    Science.gov (United States)

    Atul Bhandakkar, Anjali; Mathew, Lini, Dr.

    2018-03-01

    The Real-Time Simulator tools have high computing technologies, improved performance. They are widely used for design and improvement of electrical systems. The advancement of the software tools like MATLAB/SIMULINK with its Real-Time Workshop (RTW) and Real-Time Windows Target (RTWT), real-time simulators are used extensively in many engineering fields, such as industry, education, and research institutions. OPAL-RT-OP4510 is a Real-Time Simulator which is used in both industry and academia. In this paper, the real-time simulation of IEEE-5-Bus network is carried out by means of OPAL-RT-OP4510 with CRO and other hardware. The performance of the network is observed with the introduction of fault at various locations. The waveforms of voltage, current, active and reactive power are observed in the MATLAB simulation environment and on the CRO. Also, Load Flow Analysis (LFA) of IEEE-5-Bus network is computed using MATLAB/Simulink power-gui load flow tool.

  10. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  11. Speeding Up Network Simulations Using Discrete Time

    OpenAIRE

    Lucas, Aaron; Armbruster, Benjamin

    2013-01-01

    We develop a way of simulating disease spread in networks faster at the cost of some accuracy. Instead of a discrete event simulation (DES) we use a discrete time simulation. This aggregates events into time periods. We prove a bound on the accuracy attained. We also discuss the choice of step size and do an analytical comparison of the computational costs. Our error bound concept comes from the theory of numerical methods for SDEs and the basic proof structure comes from the theory of numeri...

  12. Fan beam image reconstruction with generalized Fourier slice theorem.

    Science.gov (United States)

    Zhao, Shuangren; Yang, Kang; Yang, Kevin

    2014-01-01

    For parallel beam geometry the Fourier reconstruction works via the Fourier slice theorem (or central slice theorem, projection slice theorem). For fan beam situation, Fourier slice can be extended to a generalized Fourier slice theorem (GFST) for fan-beam image reconstruction. We have briefly introduced this method in a conference. This paper reintroduces the GFST method for fan beam geometry in details. The GFST method can be described as following: the Fourier plane is filled by adding up the contributions from all fanbeam projections individually; thereby the values in the Fourier plane are directly calculated for Cartesian coordinates such avoiding the interpolation from polar to Cartesian coordinates in the Fourier domain; inverse fast Fourier transform is applied to the image in Fourier plane and leads to a reconstructed image in spacial domain. The reconstructed image is compared between the result of the GFST method and the result from the filtered backprojection (FBP) method. The major differences of the GFST and the FBP methods are: (1) The interpolation process are at different data sets. The interpolation of the GFST method is at projection data. The interpolation of the FBP method is at filtered projection data. (2) The filtering process are done in different places. The filtering process of the GFST is at Fourier domain. The filtering process of the FBP method is the ramp filter which is done at projections. The resolution of ramp filter is variable with different location but the filter in the Fourier domain lead to resolution invariable with location. One advantage of the GFST method over the FBP method is in short scan situation, an exact solution can be obtained with the GFST method, but it can not be obtained with the FBP method. The calculation of both the GFST and the FBP methods are at O(N^3), where N is the number of pixel in one dimension.

  13. Action simulation: time course and representational mechanisms

    Science.gov (United States)

    Springer, Anne; Parkinson, Jim; Prinz, Wolfgang

    2013-01-01

    The notion of action simulation refers to the ability to re-enact foreign actions (i.e., actions observed in other individuals). Simulating others' actions implies a mirroring of their activities, based on one's own sensorimotor competencies. Here, we discuss theoretical and experimental approaches to action simulation and the study of its representational underpinnings. One focus of our discussion is on the timing of internal simulation and its relation to the timing of external action, and a paradigm that requires participants to predict the future course of actions that are temporarily occluded from view. We address transitions between perceptual mechanisms (referring to action representation before and after occlusion) and simulation mechanisms (referring to action representation during occlusion). Findings suggest that action simulation runs in real-time; acting on newly created action representations rather than relying on continuous visual extrapolations. A further focus of our discussion pertains to the functional characteristics of the mechanisms involved in predicting other people's actions. We propose that two processes are engaged, dynamic updating and static matching, which may draw on both semantic and motor information. In a concluding section, we discuss these findings in the context of broader theoretical issues related to action and event representation, arguing that a detailed functional analysis of action simulation in cognitive, neural, and computational terms may help to further advance our understanding of action cognition and motor control. PMID:23847563

  14. Real-Time Human in the Loop MBS Simulation in the Fraunhofer Robot-Based Driving Simulator

    Directory of Open Access Journals (Sweden)

    Kleer Michael

    2014-08-01

    Full Text Available The paper encompasses the overview of hardware architecture and the systems characteristics of the Fraunhofer driving simulator. First, the requirements of the real-time model and the real-time calculation hardware are defined and discussed in detail. Aspects like transport delay and the parallel computation of complex real-time models are presented. In addition, the interfacing of the models with the simulator system is shown. Two simulator driving tests, including a fully interactive rough terrain driving with a wheeled excavator and a test drive with a passenger car, are set to demonstrate system characteristics. Furthermore, the simulator characteristics of practical significance, such as simulator response time delay, simulator acceleration signal bandwidth obtained from artificial excitation and from the simulator driving test, will be presented and discussed.

  15. Relationship between moisture content and electrical impedance of carrot slices during drying

    Science.gov (United States)

    Kertész, Ákos; Hlaváčová, Zuzana; Vozáry, Eszter; Staroňová, Lenka

    2015-01-01

    Electrical properties of food materials can give information about the inner structure and physiological state of biological tissues. Generally, the process of drying of fruits and vegetables is followed by weight loss. The aim of this study was to measure the impedance spectra of carrot slices during drying and to correlate impedance parameters to moisture content in different drying periods. Cylindrical slices were cut out from the carrot root along the axis. The slices were dried in a Venticell 111 air oven at 50°C. The weight of the slices was measured with a Denver SI-603 electronic analytical and precision balance. The weighing of the samples was performed every 30 min at the beginning of drying and every 60 min after the process. The moisture content of the samples was calculated on wet basis. The magnitude and phase angle of electrical impedance of the slices were measured with HP 4284A and 4285A precision LCR meters in the frequency range from 30 Hz to 1 MHz and from 75 kHz to 30 MHz, respectively, at voltage 1 V. The impedance measurement was performed after weighting. The change in the magnitude of impedance during drying showed a good correlation with the change in the moisture content.

  16. Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time

    International Nuclear Information System (INIS)

    Zhang, Shi-Zheng; Hu, Xiu-Hua; Zhang, Qiao-Wei; Huang, Wen-Xin

    2005-01-01

    The aim of our study is to evaluate computed tomography (CT) coronary angiography in patients with a high heart rate using 16-slice spiral CT with 0.37-s gantry rotation time. We compare the image quality of patients whose heart rates were over 70 beats per minute (bpm) with that of patients whose heart rates were 70 bpm or less. Sixty patients with various heart rates underwent retrospectively ECG-gated multislice spiral CT (MSCT) coronary angiography. Two experienced observers who were blind to the heart rates of the patients evaluated all the MSCT coronary angiographic images and calculated the assessable segments. A total of 620 out of 891 (69.6%) segments were satisfactorily visualized. On average, 10.3 coronary artery segments per patient could be evaluated. In 36 patients whose heart rates were below 70 bpm [mean 62.2 bpm±5.32 (standard deviation, SD)], the number of assessable segments was 10.72±2.02 (SD). In the other 24 patients whose heart rates were above 70 bpm [mean 78.6 bpm±8.24 (SD)], the corresponding number was 9.75±1.74 (SD). No statistically significant difference was found in these two subgroups' t test, P>0.05. The new generation of 16-slice spiral CT with 0.37-s rotation time can satisfactorily evaluate the coronary arteries of patients with high heart rates (above 70 bpm, up to 102 bpm). (orig.)

  17. The effects of drying on physical properties of bilimbi slices (Averrhoa bilimbi l.)

    Science.gov (United States)

    Shahari, N.; Nursabrina, M.; Suhairah, A. Zai

    2015-05-01

    Physical appearance analyses of fruits are used to maintain food quality throughout and at the end of processing. However, control variables have to be designed to obtained the desired food quality. In the present study, the effects of pretreatment and drying air temperatures of 50°C, 60°C and 70°C on the drying kinetics of belimbi slices were investigated using a hot-air dryer. In order to investigate and select the appropriate drying model, seven experiment based mathematical drying models were fitted to the experimental data. According to the statistical criteria (R2, SSE and RMSE), a Logarithmic model was found to be the best model to describe the drying behaviour of belimbi slices at 40°C for control; The Page/modified Page model was the best model to describe drying behaviour at 40°C, 60°C pre-treatment and 50°C for the control and the Wang and Singh model fitted well for 50°C pre-treatment and 60°C for the control. Comparison between experiment based mathematical modelling with a single phase mathematical model shows that close agreement was produced. The qualities of belimbi slices in terms of colour, texture and shrinkage with different air temperature and pre-treatment were also investigated. Higher drying temperatures gives less drying time, a lighter colour but greater product shrinkage, whilst pre-treatment can reduce product shrinkage and drying time and can also give good texture properties. The results show that pre-treatment and the drying temperature are important to improve mass and heat transfer as well as the product characteristics such as colour, shrinkage and texture.

  18. Development and operation of a real-time simulation at the NASA Ames Vertical Motion Simulator

    Science.gov (United States)

    Sweeney, Christopher; Sheppard, Shirin; Chetelat, Monique

    1993-01-01

    The Vertical Motion Simulator (VMS) facility at the NASA Ames Research Center combines the largest vertical motion capability in the world with a flexible real-time operating system allowing research to be conducted quickly and effectively. Due to the diverse nature of the aircraft simulated and the large number of simulations conducted annually, the challenge for the simulation engineer is to develop an accurate real-time simulation in a timely, efficient manner. The SimLab facility and the software tools necessary for an operating simulation will be discussed. Subsequent sections will describe the development process through operation of the simulation; this includes acceptance of the model, validation, integration and production phases.

  19. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Multi-slice spiral CT detects spread of small laryngeal tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Schoepf, U.; Becker, C.; Reiser, M.; Hong, C.; Sturm, C.; Wollenberg, B.

    1999-01-01

    The purpose of the study was to preoperatively investigate small laryngeal carcinomas using multi-slice spiral CT (MSCT) and subsequent multiplanar reconstructions (MPR) and to compare the results to the detailed spread found a surgery and histology. Nine patients with small (T1, T2) laryngeal cancer were investigated on a MSCT scanner (Siemens plus 4 Volume Zoom, Siemens). A 4x1 mm collimation, 120 kV, 200 mAs and a 0.5 seconds rotation time were used, allowing a coverage of the entire larynx in approximately 10 seconds within a single breathhold. Multiplanar reconstruction's (MPR) in sagittal and coronal plane were reconstructed in all patients and rated in consensus reading. In 8 of nine patients, the glottic spread was detected by MSCT, in one case of a supraglottic tumor a glottic invasion was excluded. The infiltration of the anterior commissure, the infiltration into the subglottic space and the extension into the hypo-pharynx was correctly assessed in all patients. MSCT was not able to predict infiltration of the arythnoids in two patients. The use of multi-slice CT for the preoperative assessment of small laryngeal tumors shows great promise. The detection or exclusion of subtle spread of these tumors into the supra- or subglottic space and along the glottic level was possible with high accuracy. As the examination time is short, artifacts are rare and multiplanar reconstructions gain in clinical importance. (orig.) [de

  1. Capitalizing Resolving Power of Density Gradient Ultracentrifugation by Freezing and Precisely Slicing Centrifuged Solution: Enabling Identification of Complex Proteins from Mitochondria by Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Haiqing Yu

    2016-01-01

    Full Text Available Density gradient centrifugation is widely utilized for various high purity sample preparations, and density gradient ultracentrifugation (DGU is often used for more resolution-demanding purification of organelles and protein complexes. Accurately locating different isopycnic layers and precisely extracting solutions from these layers play a critical role in achieving high-resolution DGU separations. In this technique note, we develop a DGU procedure by freezing the solution rapidly (but gently after centrifugation to fix the resolved layers and by slicing the frozen solution to fractionate the sample. Because the thickness of each slice can be controlled to be as thin as 10 micrometers, we retain virtually all the resolution produced by DGU. To demonstrate the effectiveness of this method, we fractionate complex V from HeLa mitochondria using a conventional technique and this freezing-slicing (F-S method. The comparison indicates that our F-S method can reduce complex V layer thicknesses by ~40%. After fractionation, we analyze complex V proteins directly on a matrix assisted laser desorption/ionization, time-of-flight mass spectrometer. Twelve out of fifteen subunits of complex V are positively identified. Our method provides a practical protocol to identify proteins from complexes, which is useful to investigate biomolecular complexes and pathways in various conditions and cell types.

  2. Microbiological quality of sliced and block mozzarella cheese

    Directory of Open Access Journals (Sweden)

    Mariana Fontanetti Marinheiro

    2015-06-01

    Full Text Available The aim of this study was to verify the microbiological quality of mozzarella cheese sold in retail markets of Pelotas, Rio Grande do Sul, Brazil. Forty samples of mozzarella cheese were analyzed, comprising 20 samples of block cheese and 20 of sliced cheese. The cheese samples were analyzed for thermotolerant coliform counts and coagulase positive staphylococci counts, and presence of Salmonella spp and Listeria monocytogenes. The percentage of 12,5% and 5% of the sliced and block cheese samples analyzed, respectively, exceeded the microbiological standards accepted by Brazilian legislation. These results indicate the need for a better product monitoring and more concern with hygiene and sanitary practices during industrial process.

  3. Trafficking of astrocytic vesicles in hippocampal slices

    International Nuclear Information System (INIS)

    Potokar, Maja; Kreft, Marko; Lee, So-Young; Takano, Hajime; Haydon, Philip G.; Zorec, Robert

    2009-01-01

    The increasingly appreciated role of astrocytes in neurophysiology dictates a thorough understanding of the mechanisms underlying the communication between astrocytes and neurons. In particular, the uptake and release of signaling substances into/from astrocytes is considered as crucial. The release of different gliotransmitters involves regulated exocytosis, consisting of the fusion between the vesicle and the plasma membranes. After fusion with the plasma membrane vesicles may be retrieved into the cytoplasm and may continue to recycle. To study the mobility implicated in the retrieval of secretory vesicles, these structures have been previously efficiently and specifically labeled in cultured astrocytes, by exposing live cells to primary and secondary antibodies. Since the vesicle labeling and the vesicle mobility properties may be an artifact of cell culture conditions, we here asked whether the retrieving exocytotic vesicles can be labeled in brain tissue slices and whether their mobility differs to that observed in cell cultures. We labeled astrocytic vesicles and recorded their mobility with two-photon microscopy in hippocampal slices from transgenic mice with fluorescently tagged astrocytes (GFP mice) and in wild-type mice with astrocytes labeled by Fluo4 fluorescence indicator. Glutamatergic vesicles and peptidergic granules were labeled by the anti-vesicular glutamate transporter 1 (vGlut1) and anti-atrial natriuretic peptide (ANP) antibodies, respectively. We report that the vesicle mobility parameters (velocity, maximal displacement and track length) recorded in astrocytes from tissue slices are similar to those reported previously in cultured astrocytes.

  4. Simulation of deep one- and two-dimensional redshift surveys

    Science.gov (United States)

    Park, Changbom; Gott, J. Richard, III

    1991-03-01

    It is shown that slice or pencil-beam redshift surveys of galaxies can be simulated in a box with nonequal sides. This method saves a lot of computer time and memory while providing essentially the same results as from whole-cube simulations. A 2457.6/h Mpc-long rod (out to a redshift z = 0.58 in two opposite directions) is simulated using the standard biased cold dark matter model as an example to mimic the recent deep pencil-beam surveys by Broadhurst et al. (1990). The structures (spikes) seen in these simulated samples occur when the narrow pencil-beam pierces walls, filaments, and clusters appearing randomly along the line-of-sight. A statistical test for goodness of fit to a periodic lattice has been applied to the observations and the simulations. It is found that the statistical significance level (P = 15.4 percent) is not strong enough to reject the null hypothesis that the observations and the simulations were drawn at random from the same set.

  5. Real-time hybrid simulation using the convolution integral method

    International Nuclear Information System (INIS)

    Kim, Sung Jig; Christenson, Richard E; Wojtkiewicz, Steven F; Johnson, Erik A

    2011-01-01

    This paper proposes a real-time hybrid simulation method that will allow complex systems to be tested within the hybrid test framework by employing the convolution integral (CI) method. The proposed CI method is potentially transformative for real-time hybrid simulation. The CI method can allow real-time hybrid simulation to be conducted regardless of the size and complexity of the numerical model and for numerical stability to be ensured in the presence of high frequency responses in the simulation. This paper presents the general theory behind the proposed CI method and provides experimental verification of the proposed method by comparing the CI method to the current integration time-stepping (ITS) method. Real-time hybrid simulation is conducted in the Advanced Hazard Mitigation Laboratory at the University of Connecticut. A seismically excited two-story shear frame building with a magneto-rheological (MR) fluid damper is selected as the test structure to experimentally validate the proposed method. The building structure is numerically modeled and simulated, while the MR damper is physically tested. Real-time hybrid simulation using the proposed CI method is shown to provide accurate results

  6. Quantification of silver nanoparticle uptake and distribution within individual human macrophages by FIB/SEM slice and view.

    Science.gov (United States)

    Guehrs, Erik; Schneider, Michael; Günther, Christian M; Hessing, Piet; Heitz, Karen; Wittke, Doreen; López-Serrano Oliver, Ana; Jakubowski, Norbert; Plendl, Johanna; Eisebitt, Stefan; Haase, Andrea

    2017-03-21

    Quantification of nanoparticle (NP) uptake in cells or tissues is very important for safety assessment. Often, electron microscopy based approaches are used for this purpose, which allow imaging at very high resolution. However, precise quantification of NP numbers in cells and tissues remains challenging. The aim of this study was to present a novel approach, that combines precise quantification of NPs in individual cells together with high resolution imaging of their intracellular distribution based on focused ion beam/ scanning electron microscopy (FIB/SEM) slice and view approaches. We quantified cellular uptake of 75 nm diameter citrate stabilized silver NPs (Ag 75 Cit) into an individual human macrophage derived from monocytic THP-1 cells using a FIB/SEM slice and view approach. Cells were treated with 10 μg/ml for 24 h. We investigated a single cell and found in total 3138 ± 722 silver NPs inside this cell. Most of the silver NPs were located in large agglomerates, only a few were found in clusters of fewer than five NPs. Furthermore, we cross-checked our results by using inductively coupled plasma mass spectrometry and could confirm the FIB/SEM results. Our approach based on FIB/SEM slice and view is currently the only one that allows the quantification of the absolute dose of silver NPs in individual cells and at the same time to assess their intracellular distribution at high resolution. We therefore propose to use FIB/SEM slice and view to systematically analyse the cellular uptake of various NPs as a function of size, concentration and incubation time.

  7. Pre-sliced fruit in school cafeterias: children's selection and intake.

    Science.gov (United States)

    Wansink, Brian; Just, David R; Hanks, Andrew S; Smith, Laura E

    2013-05-01

    It is often assumed that children avoid fruit in school cafeterias because of higher relative prices and preferences for other foods. Interviews with children reveal that eating whole fresh fruit can be difficult for those with small mouths or braces. Older girls find whole fruits messy and unattractive to eat. To determine the effect of offering pre-sliced fruit in schools on selection and intake. Three of six schools were assigned randomly to serve apples in slices. Three control schools served apples whole. Selection, consumption, and waste of apples were measured prior to and during treatment. Cafeterias in six public middle schools in Wayne County NY in 2011. Participants included all students who purchased lunch on days when data were collected. Treatment schools were provided with a standard commercial fruit slicer, and cafeteria staff members were instructed to use it when students requested apples. Trained researchers recorded how much of each apple was consumed and how much was wasted in both control and treatment schools. Daily apple sales, percentage of an apple serving consumed per student, and percentage of an apple serving wasted per student. Data were analyzed in 2012. Schools that used fruit slicers to pre-slice fruit increased average daily apple sales by 71% compared to control schools (papples and ate more than half increased by 73% (p=0.02) at schools that served pre-sliced fruit, and the percentage that wasted half or more decreased by 48% (p=0.03). Sliced fruit is more appealing to children than whole fruit because it is easier and tidier to eat. This study applies the principle of convenience from behavioral economics and provides an example of a scalable, low-cost environmental change that promotes healthy eating and decreases waste. Copyright © 2013. Published by Elsevier Inc. on behalf of American Journal of Preventive Medicine.

  8. A time resolving data acquisition system for multiple high-resolution position sensitive detectors

    International Nuclear Information System (INIS)

    Dimmler, D.G.

    1988-01-01

    An advanced time resolving data collection system for use in neutron and x-ray spectrometry has been implemented and put into routine operation. The system collects data from high-resolution position-sensitive area detectors with a maximum cumulative rate of 10/sup 6/ events per second. The events are sorted, in real-time, into many time-slice arrays. A programmable timing control unit allows for a wide choice of time sequences and time-slice array sizes. The shortest dwell time on a slice may be below 1 ms and the delay to switch between slices is zero

  9. Dried fruit breadfruit slices by Refractive Window™ technique

    Directory of Open Access Journals (Sweden)

    Diego F. Tirado

    2016-01-01

    Full Text Available A large amount of products are dried due several reasons as preservation, weight reduction and improvement of stability. However, on the market are not offered low-cost and high quality products simultaneously. Although there are effective methods of dehydrating foods such as freeze drying, which preserves the flavor, color and vitamins, they are poor accessibility technologies. Therefore, alternative processes are required to be efficient and economical. The aim of this research was compare drying kinetics of sliced of breadfruit (Artocarpus communis using the technique of Refractive Window® (VR with the tray drying. To carry out this study, sliced of 1 and 2 mm thick were used. Refractive window drying was performed with the water bath temperature to 92 °C; and tray drying at 62 °C and an air velocity of 0.52 m/s. During the Refractive window drying technique, the moisture content reached the lower than tray drying levels. Similarly it happened with samples of 1 mm, which, having a smaller diameter reached lower moisture levels than samples 2 mm. The higher diffusivities were obtained during drying sliced VR 1 and 2 mm with coefficients of 6.13 and 3.90*10-9 m2/s respectively.

  10. Transverse Slicing of the Sixth-Seventh Costal Cartilaginous Junction: A Novel Technique to Prevent Warping in Nasal Surgery.

    Science.gov (United States)

    Teshima, Tara Lynn; Cheng, Homan; Pakdel, Amir; Kiss, Alex; Fialkov, Jeffrey A

    2016-01-01

    Costal cartilage is an important reconstructive tissue for correcting nasal deformities. Warping of costal cartilage, a recognized complication, can lead to significant functional and aesthetic problems. The authors present a technique to prevent warping that involves transverse slicing of the sixth-seventh costal cartilaginous junction, that when sliced perpendicular to the long axis of the rib, provides multiple long, narrow, clinically useful grafts with balanced cross-sections. The aim was to measure differences in cartilage warp between this technique (TJS) and traditional carving techniques. Costal cartilage was obtained from human subjects and cut to clinically relevant dimensions using a custom cutting jig. The sixth-seventh costal cartilaginous junction was sliced transversely leaving the outer surface intact. The adjacent sixth rib cartilage was carved concentrically and eccentrically. The samples were incubated and standardized serial photography was performed over time up to 4 weeks. Warp was quantified by measuring nonlinearity of the grafts using least-squares regression and compared between carving techniques. TJS grafts (n = 10) resulted in significantly less warp than both eccentrically (n = 3) and concentrically carved grafts (n = 3) (P < 0.0001). Warp was significantly higher with eccentric carving compared with concentric carving (P < 0.0001). Warp increased significantly with time for both eccentric (P = 0002) and concentric (P = 0.0007) techniques while TJS warp did not (P = 0.56). The technique of transverse slicing costal cartilage from the sixth-seventh junction minimizes warp compared with traditional carving methods providing ample grafts of adequate length and versatility for reconstructive requirements.

  11. Computation of a voxelized anthropomorphic phantom from Computer Tomography slices and 3D dose distribution calculation utilizing the MCNP5 Code

    International Nuclear Information System (INIS)

    Abella, V.; Miro, R.; Juste, B.; Verdu, G.

    2008-01-01

    Full text: The purpose of this work is to obtain the voxelization of a series of tomography slices in order to provide a voxelized human phantom throughout a MatLab algorithm, and the consequent simulation of the irradiation of such phantom with the photon beam generated in a Theratron 780 (MDS Nordion) 60 Co radiotherapy unit, using the Monte Carlo transport code MCNP (Monte Carlo N-Particle), version 5. The project provides as results dose mapping calculations inside the voxelized anthropomorphic phantom. Prior works have validated the cobalt therapy model utilizing a simple heterogeneous water cube-shaped phantom. The reference phantom model utilized in this work is the Zubal phantom, which consists of a group of pre-segmented CT slices of a human body. The CT slices are to be input into the Matlab program which computes the voxelization by means of two-dimensional pixel and material identification on each slice, and three-dimensional interpolation, in order to depict the phantom geometry via small cubic cells. Each slice is divided in squares with the size of the desired voxelization, and then the program searches for the pixel intensity with a predefined material at each square, making a subsequent three-dimensional interpolation. At the end of this process, the program produces a voxelized phantom in which each voxel defines the mixture of the different materials that compose it. In the case of the Zubal phantom, the voxels result in pure organ materials due to the fact that the phantom is presegmented. The output of this code follows the MCNP input deck format and is integrated in a full input model including the 60 Co radiotherapy unit. Dose rates are calculated using the MCNP5 tool FMESH, superimposed mesh tally. This feature allows to tally particles on an independent mesh over the problem geometry, and to obtain the length estimation of the particle flux, in units of particles/cm 2 (tally F4). Furthermore, the particle flux is transformed into dose by

  12. Ionizing radiation action of transport systems of Na+ and K+ of neutronal membranes. Potassium ions reaccumulation with brain slices

    International Nuclear Information System (INIS)

    Dvoretsky, A.I.; Shainskaya, A.M.; Ananyeva, T.V.; Kulikova, I.A.

    1990-01-01

    The biological effect of ionizing radiation (IR) on the Na,K pump of the surviving brain cortex slices was investigated. It was shown that IR leads to marked disturbances in the Na,K pump activity and causes essential phasic changes in potassium ion reaccumulation by brain slices in different time after exposure. The possibility of modelling the radiation effect with the help of phospholipase A2 and decylenic acid was shown. The mechanisms of the functional disturbance of Na-K pump of nerve cells after irradiation are under discussion. (author)

  13. Automatic Solitary Lung Nodule Detection in Computed Tomography Images Slices

    Science.gov (United States)

    Sentana, I. W. B.; Jawas, N.; Asri, S. A.

    2018-01-01

    Lung nodule is an early indicator of some lung diseases, including lung cancer. In Computed Tomography (CT) based image, nodule is known as a shape that appears brighter than lung surrounding. This research aim to develop an application that automatically detect lung nodule in CT images. There are some steps in algorithm such as image acquisition and conversion, image binarization, lung segmentation, blob detection, and classification. Data acquisition is a step to taking image slice by slice from the original *.dicom format and then each image slices is converted into *.tif image format. Binarization that tailoring Otsu algorithm, than separated the background and foreground part of each image slices. After removing the background part, the next step is to segment part of the lung only so the nodule can localized easier. Once again Otsu algorithm is use to detect nodule blob in localized lung area. The final step is tailoring Support Vector Machine (SVM) to classify the nodule. The application has succeed detecting near round nodule with a certain threshold of size. Those detecting result shows drawback in part of thresholding size and shape of nodule that need to enhance in the next part of the research. The algorithm also cannot detect nodule that attached to wall and Lung Chanel, since it depend the searching only on colour differences.

  14. Distortion-Based Slice Level Prioritization for Real-Time Video over QoS-Enabled Wireless Networks

    Directory of Open Access Journals (Sweden)

    Ismail A. Ali

    2012-01-01

    Full Text Available This paper presents a prioritization scheme based on an analysis of the impact on objective video quality when dropping individual slices from coded video streams. It is shown that giving higher-priority classified packets preference in accessing the wireless media results in considerable quality gain (up to 3 dB in tests over the case when no prioritization is applied. The proposed scheme is demonstrated for an IEEE 802.11e quality-of-service- (QoS- enabled wireless LAN. Though more complex prioritization systems are possible, the proposed scheme is crafted for mobile interactive or user-to-user video services and is simply implemented within the Main or the Baseline profiles of an H.264 codec.

  15. Thin-layer catalytic far-infrared radiation drying and flavour of tomato slices

    Directory of Open Access Journals (Sweden)

    Ernest Ekow Abano

    2014-06-01

    Full Text Available A far-infrared radiation (FIR catalytic laboratory dryer was designed by us and used to dry tomato. The kinetics of drying of tomato slices with FIR energy was dependent on both the distance from the heat source and the sample thickness. Numerical evaluation of the simplified Fick’s law for Fourier number showed that the effective moisture diffusivity increased from 0.193×10–9 to 1.893×10–9 m2/s, from 0.059×10–9 to 2.885×10–9 m2/s, and, from 0.170×10–9 to 4.531×10–9 m2/s for the 7, 9, and 11 mm thick slices as moisture content decreased. Application of FIR enhanced the flavour of the dried tomatoes by 36.6% when compared with the raw ones. The results demonstrate that in addition to shorter drying times, the flavour of the products can be enhanced with FIR. Therefore, FIR drying should be considered as an efficient drying method for tomato with respect to minimization of processing time, enhancement in flavour, and improvements in the quality and functional property of dried tomatoes.

  16. High-throughput optimization by statistical designs: example with rat liver slices cryopreservation.

    Science.gov (United States)

    Martin, H; Bournique, B; Blanchi, B; Lerche-Langrand, C

    2003-08-01

    The purpose of this study was to optimize cryopreservation conditions of rat liver slices in a high-throughput format, with focus on reproducibility. A statistical design of 32 experiments was performed and intracellular lactate dehydrogenase (LDHi) activity and antipyrine (AP) metabolism were evaluated as biomarkers. At freezing, modified University of Wisconsin solution was better than Williams'E medium, and pure dimethyl sulfoxide was better than a cryoprotectant mixture. The best cryoprotectant concentrations were 10% for LDHi and 20% for AP metabolism. Fetal calf serum could be used at 50 or 80%, and incubation of slices with the cryoprotectant could last 10 or 20 min. At thawing, 42 degrees C was better than 22 degrees C. After thawing, 1h was better than 3h of preculture. Cryopreservation increased the interslice variability of the biomarkers. After cryopreservation, LDHi and AP metabolism levels were up to 84 and 80% of fresh values. However, these high levels were not reproducibly achieved. Two factors involved in the day-to-day variability of LDHi were identified: the incubation time with the cryoprotectant and the preculture time. In conclusion, the statistical design was very efficient to quickly determine optimized conditions by simultaneously measuring the role of numerous factors. The cryopreservation procedure developed appears suitable for qualitative metabolic profiling studies.

  17. Adaptive slices for acquisition of anisotropic BRDF

    Czech Academy of Sciences Publication Activity Database

    Vávra, Radomír; Filip, Jiří

    (2018) ISSN 2096-0433 R&D Projects: GA ČR GA17-18407S Institutional support: RVO:67985556 Keywords : anisotropic BRDF * slice * sampling Subject RIV: BD - Theory of Information http://library.utia.cas.cz/separaty/2018/RO/vavra-0486116.pdf

  18. Real time simulator for material testing reactor

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Noriyuki; Imaizumi, Tomomi; Izumo, Hironobu; Hori, Naohiko; Suzuki, Masahide [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Ishitsuka, Tatsuo; Tamura, Kazuo [ITOCHU Techno-Solutions Corp., Tokyo (Japan)

    2012-03-15

    Japan Atomic Energy Agency (JAEA) is now developing a real time simulator for a material testing reactor based on Japan Materials Testing Reactor (JMTR). The simulator treats reactor core system, primary and secondary cooling system, electricity system and irradiation facility systems. Possible simulations are normal reactor operation, unusual transient operation and accidental operation. The developed simulator also contains tool to revise/add facility in it for the future development. (author)

  19. Real time simulator for material testing reactor

    International Nuclear Information System (INIS)

    Takemoto, Noriyuki; Imaizumi, Tomomi; Izumo, Hironobu; Hori, Naohiko; Suzuki, Masahide; Ishitsuka, Tatsuo; Tamura, Kazuo

    2012-01-01

    Japan Atomic Energy Agency (JAEA) is now developing a real time simulator for a material testing reactor based on Japan Materials Testing Reactor (JMTR). The simulator treats reactor core system, primary and secondary cooling system, electricity system and irradiation facility systems. Possible simulations are normal reactor operation, unusual transient operation and accidental operation. The developed simulator also contains tool to revise/add facility in it for the future development. (author)

  20. Organotypic slice cultures containing the preBötzinger complex generate respiratory-like rhythms

    DEFF Research Database (Denmark)

    Phillips, Wiktor S; Herly, Mikkel; Del Negro, Christopher A

    2016-01-01

    containing the preBötzinger complex (preBötC), the core inspiratory rhythm generator of the ventrolateral brainstem. We measured bilateral synchronous network oscillations, using calcium-sensitive fluorescent dyes, in both ventrolateral (presumably the preBötC) and dorsomedial regions of 7-43 days in vitro......Acute brainstem slice preparations in vitro have advanced understanding of the cellular and synaptic mechanisms of respiratory rhythm generation, but their inherent limitations preclude long-term manipulation and recording experiments. Here, we developed an organotypic slice culture preparation...... of the brainstem displayed up to 193% faster burst frequency (22.4 ± 8.3 bursts/min) and higher signal amplitude (340%) compared to acute slices. We conclude that preBötC-containing slice cultures retain inspiratory-like rhythmic function and therefore may facilitate lines of experimentation that involve extended...

  1. Imaging by the SSFSE single slice method at different viscosities of bile

    International Nuclear Information System (INIS)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi

    2001-01-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T 2 . However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T 2 value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T 2 value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T 1 - and T 2 -weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T 2 values of the bile samples showing relatively high signal intensities on the T 1 -weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T 1 -weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  2. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  3. Real time animation of space plasma phenomena

    International Nuclear Information System (INIS)

    Jordan, K.F.; Greenstadt, E.W.

    1987-01-01

    In pursuit of real time animation of computer simulated space plasma phenomena, the code was rewritten for the Massively Parallel Processor (MPP). The program creates a dynamic representation of the global bowshock which is based on actual spacecraft data and designed for three dimensional graphic output. This output consists of time slice sequences which make up the frames of the animation. With the MPP, 16384, 512 or 4 frames can be calculated simultaneously depending upon which characteristic is being computed. The run time was greatly reduced which promotes the rapid sequence of images and makes real time animation a foreseeable goal. The addition of more complex phenomenology in the constructed computer images is now possible and work proceeds to generate these images

  4. Simulating last interglacial climate with NorESM: role of insolation and greenhouse gases in the timing of peak warmth

    Directory of Open Access Journals (Sweden)

    P.M. Langebroek

    2014-07-01

    Full Text Available The last interglacial (LIG, ~130–116 ka, ka = 1000 yr ago is characterized by high-latitude warming and is therefore often considered as a possible analogue for future warming. However, in contrast to predicted future greenhouse warming, the LIG climate is largely governed by variations in insolation. Greenhouse gas (GHG concentrations were relatively stable and similar to pre-industrial values, with the exception of the early LIG when, on average, GHGs were slightly lower. We performed six time-slice simulations with the low-resolution version of the Norwegian Earth System Model covering the LIG. In four simulations only the orbital forcing was changed. In two other simulations, representing the early LIG, additionally the GHG forcing was reduced. With these simulations we investigate (1 the different effects of GHG versus insolation forcing on the temperatures during the LIG; (2 whether reduced GHGs can explain the low temperatures reconstructed for the North Atlantic; and (3 the timing of the observed LIG peak warmth. Our simulations show that the insolation forcing results in seasonal and hemispheric differences in temperature. In contrast, a reduction in the GHG forcing causes a global and seasonal-independent cooling. Furthermore, we compare modelled temperatures with proxy-based LIG sea-surface temperatures along a transect in the North Atlantic. The modelled North Atlantic summer sea-surface temperatures capture the general trend of the reconstructed summer temperatures, with low values in the early LIG, a peak around 125 ka, and a steady decrease towards the end of the LIG. Simulations with reduced GHG forcing improve the model–data fit as they show lower temperatures in the early LIG. Furthermore we show that the timing of maximum summer and winter surface temperatures is in line with the local summer and winter insolation maximum at most latitudes. Two regions where the maximum local insolation and temperature do not occur at the

  5. Modelling the Drying Characteristics and Kinetics of Hot Air-Drying of Unblanched Whole Red Pepper and Blanched Bitter Leaf Slices

    OpenAIRE

    Samuel Enahoro Agarry

    2017-01-01

    The objective of this study was to investigate the drying characteristics and kinetics of red pepper and bitter leaf under the influence of different drying temperatures. The drying experiments were carried out at dry bulb temperature of 35, 45, 55 and 75oC, respectively in an oven dryer. The results showed that as drying temperature increased, drying rate also increased and the drying time decreased. It was observed that un-sliced red pepper and sliced bitter leaf would dry within 2.5-12 h a...

  6. Time-dependent effect of p-Aminophenol (PAP) toxicity in renal slices and development of oxidative stress

    International Nuclear Information System (INIS)

    Harmon, R. Christopher; Terneus, Marcus V.; Kiningham, Kinsley K.; Valentovic, Monica

    2005-01-01

    p-Aminophenol (PAP), a metabolite of acetaminophen, is nephrotoxic. This study investigated PAP-mediated changes as a function of time that occur prior to loss of membrane integrity. Experiments further evaluated the development of oxidative stress by PAP. Renal slices from male Fischer 344 (F344) rats (N = 4-6) were exposed to 0.1, 0.25, and 0.5 mM PAP for 15-120 min under oxygen and constant shaking at 37 o C. Pyruvate-stimulated gluconeogenesis, adenine nucleotide levels, and total glutathione (GSH) levels were diminished in a concentration- and time-dependent manner prior to detection of a rise in lactate dehydrogenase (LDH) leakage. Glutathione disulfide (GSSG) levels were increased by PAP suggesting the induction of oxidative stress. Western blot analysis confirmed a rise in 4-hydroxynonenal (4-HNE)-adducted proteins in tissues exposed to 0.1 and 0.25 mM PAP for 90 min. The appearance of 4-HNE-adducted proteins at the 0.1 mM concentration of PAP occurred prior to development of increased LDH leakage. Pretreatment with 1 mM glutathione (GSH) for 30 min only partially reduced PAP toxicity as LDH values were less severely depleted relative to tissues not pretreated with GSH. In contrast, pretreatment for 15 min with 2 mM ascorbic acid completely protected against PAP toxicity. Further studies showed that ascorbic acid pretreatment prevented PAP-mediated depletion of GSH. In summary, PAP rapidly depletes GSH and adenine nucleotides and inhibits gluconeogenesis prior to a rise in LDH leakage. PAP induces oxidative stress as indicated by an increase in GSSG and 4-HNE-adducted proteins. Ascorbic acid pretreatment prevents PAP toxicity by maintaining GSH status

  7. Demonstration of the pulmonary interlobar fissures on multiplanar reformatted images with 64-slices spiral CT

    International Nuclear Information System (INIS)

    Wang Yafei; Chen Yerong; Shan Xiuhong; Tang Zhiyang; Ni Enzhen; Huang Hao; Wu Shuchun

    2009-01-01

    Objective: To determine the optimal orientation and slice thickness of reformatted images to visualize the interlobar fissures on multiplanar reformation (MPR) images and to recommend MPR imaging protocal for visualizing interlobar fissures in clinical practise. Methods: 64-slices CT scans of chest were obtained in 300 patients without pulmonary diseases. Axial, sagittal and coronal images were reformatted at 1, 2, 3, 7 mm slice thickness respectively from the raw volume data. Three experienced radiologists evaluated all of the MPR images in the lung window and compared the differences in visualization of the interlohar fissures among the three reformatted orientations and at the different slice thicknesses with Fisher test and Friedman test. Results: Fissures on sagittal MPR images using 1, 2, 3, and 7 mm reformatted slice thickness appeared as a fine line and the preference value analysis showed the MPR images with a 3 mm reformatted slice thickness is the best for visualizing the interlobar fissure. Compared to the sagittal orientation, the coronal was not as good and the axial was the worst among the three orientations. The coronal images with a 3 mm reformatted slice thickness were slightly inferior to sagittal images. The right horizontal fissures were observed as a fine line in all coronal image in 94.0% (282)of cases and in some of the images in 6.0% (18) of cases, the right oblique fissures were displayed as a fine line in coronal images in 2.3% (7) of cases and in some images in 85.0% (255) of cases, the left oblique fissures were displayed as a fine line in some coronal images in 35.7% (107) of cases and displayed as a coarse line in 64.3% (193) of cases. On axial MPR images using 3 mm reformation slice thickness, the right oblique fissures and the left oblique fissures were displayed as a fine line in some axial images in 79.3% (238) and 81.0% (243) of cases respectively, none of the images showed horizontal fissures as a fine line. There was

  8. Dibucaine mitigates spreading depolarization in human neocortical slices and prevents acute dendritic injury in the ischemic rodent neocortex.

    Directory of Open Access Journals (Sweden)

    W Christopher Risher

    Full Text Available Spreading depolarizations that occur in patients with malignant stroke, subarachnoid/intracranial hemorrhage, and traumatic brain injury are known to facilitate neuronal damage in metabolically compromised brain tissue. The dramatic failure of brain ion homeostasis caused by propagating spreading depolarizations results in neuronal and astroglial swelling. In essence, swelling is the initial response and a sign of the acute neuronal injury that follows if energy deprivation is maintained. Choosing spreading depolarizations as a target for therapeutic intervention, we have used human brain slices and in vivo real-time two-photon laser scanning microscopy in the mouse neocortex to study potentially useful therapeutics against spreading depolarization-induced injury.We have shown that anoxic or terminal depolarization, a spreading depolarization wave ignited in the ischemic core where neurons cannot repolarize, can be evoked in human slices from pediatric brains during simulated ischemia induced by oxygen/glucose deprivation or by exposure to ouabain. Changes in light transmittance (LT tracked terminal depolarization in time and space. Though spreading depolarizations are notoriously difficult to block, terminal depolarization onset was delayed by dibucaine, a local amide anesthetic and sodium channel blocker. Remarkably, the occurrence of ouabain-induced terminal depolarization was delayed at a concentration of 1 µM that preserves synaptic function. Moreover, in vivo two-photon imaging in the penumbra revealed that, though spreading depolarizations did still occur, spreading depolarization-induced dendritic injury was inhibited by dibucaine administered intravenously at 2.5 mg/kg in a mouse stroke model.Dibucaine mitigated the effects of spreading depolarization at a concentration that could be well-tolerated therapeutically. Hence, dibucaine is a promising candidate to protect the brain from ischemic injury with an approach that does not rely on

  9. The effect of slicing type on drying kinetics and quality of dried carrot

    Directory of Open Access Journals (Sweden)

    M Naghipour zadeh mahani

    2016-04-01

    , wavy blade and Ridged blade and the cutting direction at 3 levels (linear, lateral and diagonal were evaluated on drying kinetics, drying rate, shrinkage and rehydration. Statistic analysis done by SPSS software. Results and Discussion: The results of analysis of variance showed that the effects of cutting parameters were significant on studied parameters (p<0.01 (Table 1. Thin layers dried faster than thick layers because of firmness of surface which it causes slow moisture transfer. The least drying time was 200 minutes at the samples that cut by a wavy blade at the lateral direction with a significant difference (p<0.05 given Fig.3. In these samples surface evaporation is more, because of more surface. The compare means showed drying rate at thick layer is fewer because of the longer distance moisture removal (Fig.6. Also the most drying rate was 0.74 gmin-1 at cutting by flat blade on linear direction with a significant difference (p<0.05.The least shrinkage was obtained on this treatment was 36.7% given Fig.8. The most of tissue of linear slices is woody part that is dense compare with other parts therefore shrinkage decrease at during drying. The most rehydration was 3.96 and 3.88 for cutting by flat blade in diagonal and linear direction with significant difference to other treatments. Rehydration depends on cell damage greatly. Since the slices of carrot that cut by flat blade were damaged fewer than other treatments therefore rehydration was more. Conclusions: The drying behavior of carrot slices was studied at different methods in slicing carrot. The results showed a significant effect of the cutting variables on drying kinetics, drying rate, shrinkage and rehydration. The carrot moisture content decreases continuously over the drying and the fastest drying occurred at thin layers sliced by wavy blade. The slices that were cut by flat blade at linear direction caused the best quality. The results show cutting parameters are significant effect on quality of

  10. Boat, wake, and wave real-time simulation

    Science.gov (United States)

    Świerkowski, Leszek; Gouthas, Efthimios; Christie, Chad L.; Williams, Owen M.

    2009-05-01

    We describe the extension of our real-time scene generation software VIRSuite to include the dynamic simulation of small boats and their wakes within an ocean environment. Extensive use has been made of the programmabilty available in the current generation of GPUs. We have demonstrated that real-time simulation is feasible, even including such complexities as dynamical calculation of the boat motion, wake generation and calculation of an FFTgenerated sea state.

  11. Computer simulations of long-time tails: what's new?

    NARCIS (Netherlands)

    Hoef, van der M.A.; Frenkel, D.

    1995-01-01

    Twenty five years ago Alder and Wainwright discovered, by simulation, the 'long-time tails' in the velocity autocorrelation function of a single particle in fluid [1]. Since then, few qualitatively new results on long-time tails have been obtained by computer simulations. However, within the

  12. Analysis of aliasing artifacts in 16-slice helical CT

    International Nuclear Information System (INIS)

    Chen Wei; Liu Jingkang; Ou Xiaoguang; Li Wenzheng; Liao Weihua; Yan Ang

    2006-01-01

    Objective: To recognize the features of aliasing artifacts on CT images, and to investigate the effects of imaging parameters on the magnitude of this artifacts. Methods: An adult dry skull was placed in a plastic water-filled container and scanned with a PHILIPS 16-slice helical CT. All the acquired transaxial images by using several different acquisition or reconstruction parameters were examined for comparative assessment of the aliasing artifacts. Results: The aliasing artifacts could be seen in most instances and characterized as the spokewise patterns emanating from the edges of high contrast structure as its radius varies sharply in the longitudinal direction. The images that scanned with pitch of 0.3, 0.6 and 0.9, respectively, showed aliasing artifacts, and its severities increased with pitches escalated (detector combination 16 x 1.5, reconstruction thickness 2 mm); There were more significant aliasing artifacts on the images reconstructed with 0.8 mm slice width compared with 1-mm slice width, and no aliasing artifacts were observed on the images reconstructed with 2-mm slice width (detector combination 16 x 0.75, pitch 0.6); No artifacts were perceived on the images scanned with detector combination 16 x 0.75, while presented evidently with the use of detector combination 16 x 1.5 (pitch 0.6, reconstruction thickness 2 mm); The degrees of aliasing artifacts were unaltered when reconstruction interval and tube current changed. Conclusions: Aliasing artifacts are caused by undersampling. When the operator choose the thinner sampling thickness, lower pitch and a much wider reconstruction thickness judiciously, aliasing artifacts could be effectively mitigated or suppressed. (authors)

  13. A real-time computer simulation of nuclear simulator software using standard PC hardware and linux environments

    International Nuclear Information System (INIS)

    Cha, K. H.; Kweon, K. C.

    2001-01-01

    A feasibility study, which standard PC hardware and Real-Time Linux are applied to real-time computer simulation of software for a nuclear simulator, is presented in this paper. The feasibility prototype was established with the existing software in the Compact Nuclear Simulator (CNS). Throughout the real-time implementation in the feasibility prototype, we has identified that the approach can enable the computer-based predictive simulation to be approached, due to both the remarkable improvement in real-time performance and the less efforts for real-time implementation under standard PC hardware and Real-Time Linux envrionments

  14. Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2002-01-01

    In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudinally for all pitches of clinical interest, and the resulting aliasing effects are spatially variant. As in the single-slice case, aliasing is shown to be negligible at the isocentre for circularly symmetric objects due to a fortuitous aliasing cancellation phenomenon. However, away from the isocentre, aliasing effects can be significant, spatially variant, and highly pitch dependent. This implies that measures more sophisticated than isocentre slice sensitivity profiles are needed to characterize longitudinal properties of multi-slice helical CT systems. Such measures are particularly important in assessing the question of whether there are preferred pitches in helical CT. Previous analyses have generally focused only on isocentre sampling patterns, and our more global analysis leads to somewhat different conclusions than have been reached before, suggesting that pitches 3, 4, 5, and 6 are favourable, and that half-integer pitches are somewhat suboptimal. (author)

  15. Effects of retail style or food service style packaging type and storage time on sensory characteristics of bacon manufactured from commercially sourced pork bellies.

    Science.gov (United States)

    Lowe, B K; Bohrer, B M; Holmer, S F; Boler, D D; Dilger, A C

    2014-06-01

    Objectives were to characterize differences in pork bellies that were stored frozen for different durations prior to processing and characterize sensory properties of the bacon derived from those bellies when stored in either retail or food service style packaging. Bellies (n = 102) were collected from 4 different time periods, fresh bellies (never frozen) and bellies frozen for 2, 5, or 7 mo, and manufactured into bacon under commercial conditions. Food service bacon was packaged in oxygen-permeable polyvinyl lined boxes layered on wax-covered lined paper and blast frozen (-33 °C) for 45 or 90 d after slicing. Retail bacon was vacuum-packaged in retail packages and refrigerated (2 °C) in the dark for 60 or 120 d after slicing. At the end of respective storage times after slicing, bacon was analyzed for sensory attributes and lipid oxidation. Off-flavor and oxidized odor of bacon increased (P food service packaged bacon from frozen bellies, but was unchanged (P ≥ 0.07) with time in food service packaged bacon from fresh bellies. Lipid oxidation was also unchanged (P ≥ 0.21) over time in retail packaged bacon, with the exception of bellies frozen for 5 mo, which was increased from day 0 to day 90. Overall, off-flavor, oxidized odor, and lipid oxidation increased as storage time after processing increased. Freezing bellies before processing may exacerbate lipid oxidation as storage time after processing was extended. Bacon can be packaged and managed several different ways before it reaches the consumer. This research simulated food service (frozen) and retail packaged (refrigerated) bacon over a range of storage times after slicing. Off-flavor and oxidized odor increased as storage time after processing increased in both packaging types. Lipid oxidation increased as storage time after slicing increased to a greater extent in food service packaging. © 2014 Institute of Food Technologists®

  16. Adaptation of Microplate-based Respirometry for Hippocampal Slices and Analysis of Respiratory Capacity

    Science.gov (United States)

    Schuh, Rosemary A.; Clerc, Pascaline; Hwang, Hyehyun; Mehrabian, Zara; Bittman, Kevin; Chen, Hegang; Polster, Brian M.

    2011-01-01

    Multiple neurodegenerative disorders are associated with altered mitochondrial bioenergetics. Although mitochondrial O2 consumption is frequently measured in isolated mitochondria, isolated synaptic nerve terminals (synaptosomes), or cultured cells, the absence of mature brain circuitry is a remaining limitation. Here we describe the development of a method that adapts the Seahorse Extracellular Flux Analyzer (XF24) for the microplate-based measurement of hippocampal slice O2 consumption. As a first evaluation of the technique, we compared whole slice bioenergetics to previous measurements made with synaptosomes or cultured neurons. We found that mitochondrial respiratory capacity and O2 consumption coupled to ATP synthesis could be estimated in cultured or acute hippocampal slices with preserved neural architecture. Mouse organotypic hippocampal slices oxidizing glucose displayed mitochondrial O2 consumption that was well-coupled, as determined by the sensitivity to the ATP synthase inhibitor oligomycin. However stimulation of respiration by uncoupler was modest (<120% of basal respiration) compared to previous measurements in cells or synaptosomes, although enhanced slightly (to ~150% of basal respiration) by the acute addition of the mitochondrial complex I-linked substrate pyruvate. These findings suggest a high basal utilization of respiratory capacity in slices and a limitation of glucose-derived substrate for maximal respiration. The improved throughput of microplate-based hippocampal respirometry over traditional O2 electrode-based methods is conducive to neuroprotective drug screening. When coupled with cell type-specific pharmacology or genetic manipulations, the ability to efficiently measure O2 consumption from whole slices should advance our understanding of mitochondrial roles in physiology and neuropathology. PMID:21520220

  17. Reduction of acrylamide formation in potato slices during frying

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Kaack, K.; Granby, Kit

    2004-01-01

    and 40 min; 90degreesC for 2 and 9 min); (iii) immersed in citric acid solutions of different concentrations (10 and 20 g/l) for half an hour. Glucose and asparagine concentration was determined in potato slices before frying, whereas acrylamide content was determined in the resultant fried potato chips...... on average 76% and 68% of the glucose and asparagine content compared to the control. Potato slices blanched at 50degreesC for 70 min surprisingly had a very low acrylamide content (28 mum/kg) even when they were fried at 190degreesC. Potato immersion in citric acid solutions of 10 and 20 g/l reduced...

  18. HUMAN LIVER SLICES EXPRESS THE SAME LIDOCAINE BIOTRANSFORMATION RATE AS ISOLATED HUMAN HEPATOCYTES

    NARCIS (Netherlands)

    OLINGA, P; MEIJER, DKF; SLOOFF, MJH; GROOTHUIS, GMM; Merema, M.T.

    1993-01-01

    In order to investigate whether liver slices are a valuable tool for the assessment of drug metabolism in human liver, we compared the phase I metabolism of lidocaine in human liver slices and hepatocytes prepared from three human livers. Lidocaine is mainly metabolised to monoethylglycinexylidide

  19. Real-Time Incompressible Fluid Simulation on the GPU

    Directory of Open Access Journals (Sweden)

    Xiao Nie

    2015-01-01

    Full Text Available We present a parallel framework for simulating incompressible fluids with predictive-corrective incompressible smoothed particle hydrodynamics (PCISPH on the GPU in real time. To this end, we propose an efficient GPU streaming pipeline to map the entire computational task onto the GPU, fully exploiting the massive computational power of state-of-the-art GPUs. In PCISPH-based simulations, neighbor search is the major performance obstacle because this process is performed several times at each time step. To eliminate this bottleneck, an efficient parallel sorting method for this time-consuming step is introduced. Moreover, we discuss several optimization techniques including using fast on-chip shared memory to avoid global memory bandwidth limitations and thus further improve performance on modern GPU hardware. With our framework, the realism of real-time fluid simulation is significantly improved since our method enforces incompressibility constraint which is typically ignored due to efficiency reason in previous GPU-based SPH methods. The performance results illustrate that our approach can efficiently simulate realistic incompressible fluid in real time and results in a speed-up factor of up to 23 on a high-end NVIDIA GPU in comparison to single-threaded CPU-based implementation.

  20. Does slice thickness affect diagnostic performance of 64-slice CT coronary angiography in stable and unstable angina patients with a positive calcium score?

    Energy Technology Data Exchange (ETDEWEB)

    Meijs, Matthijs F.L.; Vos, Alexander M. de; Cramer, Maarten J.; Doevendans, Pieter A.; Vries, Jan J.J. de; Rutten, Annemarieke; Budde, Ricardo P.J.; Prokop, Mathias (Dept. of Radiology, Univ. Medical Center Utrecht, Utrecht (Netherlands)), e-mail: m.meijs@umcutrecht.nl; Meijboom, W. Bob; Feyter, Pim J. de (Dept. of Cardiology, Erasmus Medical Center, Rotterdam (Netherlands))

    2010-05-15

    Background: Coronary calcification can lead to over-estimation of the degree of coronary stenosis. Purpose: To evaluate whether thinner reconstruction thickness improves the diagnostic performance of 64-slice CT coronary angiography (CTCA) in angina patients with a positive calcium score. Material and Methods: We selected 20 scans from a clinical study comparing CTCA to conventional coronary angiography (CCA) in stable and unstable angina patients based on a low number of motion artifacts and a positive calcium score. All images were acquired at 64 x 0.625 mm and each CTCA scan was reconstructed at slice thickness/increment 0.67 mm/0.33 mm, 0.9 mm/0.45 mm, and 1.4 mm/0.7 mm. Two reviewers blinded for CCA results independently evaluated the scans for the presence of significant coronary artery disease (CAD) in three randomly composed series, with =2 weeks in between series. The diagnostic performance of CTCA was compared for the different slice thicknesses using a pooled analysis of both reviewers. Significant CAD was defined as >50% diameter narrowing on quantitative CCA. Image noise (standard deviation of CT numbers) was measured in all scans. Inter-observer variability was assessed with kappa. Results: Significant CAD was present in 8% of 304 available segments. Median total Agatston calcium score was 181.8 (interquartile range 34.9-815.6). Sensitivity at 0.67 mm, 0.9 mm, and 1.4 mm slice thickness was 70% (95% confidence interval 57-83%), 74% (62-86%), and 70% (57-83%), respectively. Specificity was 85% (82-88%), 84% (81-87%), and 84% (81-87%), respectively. The positive predictive value was 30 (21-38%), 29 (21-37%), and 28 (20-36%), respectively. The negative predictive value was 97% (95-98%), 97% (96-99%), and 97% (96-99%), respectively. Kappa for inter-observer agreement was 0.56, 0.58, and 0.59. Noise decreased from 32.9 HU at 0.67 mm, to 23.2 HU at 1.4 mm (P<0.001). Conclusion: Diagnostic performance of CTCA in angina patients with a positive calcium score

  1. In vitro imaging of coronary artery stents: Are there differences between 16- and 64-slice CT scanners?

    International Nuclear Information System (INIS)

    Wolf, Florian; Feuchtner, Gudrun M.; Homolka, Peter; Langenberger, Herbert; Stadler, Alfred; Bader, Till R.; Weber, Michael; Lammer, Johannes; Loewe, Christian

    2008-01-01

    Purpose: To compare the performance of 64-slice with 16-slice CT scanners for the in vitro evaluation of coronary artery stents. Methods and materials: Twelve different coronary artery stents were placed in the drillings of a combined heart and chest phantom, which was scanned with a 16- and 64-slice CT scanner. Coronal reformations were evaluated for artificial lumen narrowing, intraluminal attenuation values, and false widening of the outer stent diameter as an indicator of artifacts outside the stent. Results: Mean artificial lumen narrowing was not significantly different between the 16- and 64-slice CT scanner (44% versus 39%; p = 0.408). The differences between the Hounsfield Units (HU) measurements inside and outside the stents were significantly lower (p = 0.001) with 64- compared to 16-slice CT. The standard deviation of the HU measurements inside the stents was significantly (p = 0.002) lower with 64- than with 16-slice CT. Artifacts outside the stents were not significantly different between the scanners (p = 0.866). Conclusion: Visualization of the in-stent lumen is improved with 64-slice CT when compared with 16-slice CT as quantified by significantly lesser intraluminal image noise and less artificial rise in intraluminal HU measurement, which is the most important parameter for the evaluation of stent patency in vivo

  2. Imaging by the SSFSE single slice method at different viscosities of bile

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi [Kawasaki Hospital, Kobe (Japan)

    2001-11-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T{sub 2}. However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T{sub 2} value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T{sub 2} value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T{sub 1}- and T{sub 2}-weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T{sub 2} values of the bile samples showing relatively high signal intensities on the T{sub 1}-weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T{sub 1}-weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  3. A study of the minimum number of slices required for quantification of pulmonary emphysema by computed tomography

    International Nuclear Information System (INIS)

    Hitsuda, Yutaka; Igishi, Tadashi; Kawasaki, Yuji

    2000-01-01

    We attempted to determine the minimum number of slices required for quantification of overall emphysema by computed tomography (CT). Forty-nine patients underwent CT scanning with a 15-mm slice interval, and 13 to 18 slices per patient were obtained. The percentage of low attenuation area (LAA%) per slice was measured with a method that we reported on previously, utilizing a CT program and NIH image. The average LAA% values for 1, 2, 3, and 6 slices evenly spaced through the lungs [LAA% (1), LAA% (2), LAA% (3), and LAA% (6)] were compared with those for all slices [LAA% (All)]. The correlation coefficients for LAA% (1), LAA% (2), LAA% (3), and LAA% (6) with LAA% (All) were 0.961, 0.981, 0.993, and 0.997, respectively. Mean differences ±SD were -3.20±4.21%, -2.32±3.00, -0.20±1.84, and -0.16±1.26, respectively. From these results, we concluded that overall emphysema can be quantified by using at least three slices: one each of the upper, middle, and lower lung. (author)

  4. Time simulation of flutter with large stiffness changes

    Science.gov (United States)

    Karpel, Mordechay; Wieseman, Carol D.

    1992-01-01

    Time simulation of flutter, involving large local structural changes, is formulated with a state-space model that is based on a relatively small number of generalized coordinates. Free-free vibration modes are first calculated for a nominal finite-element model with relatively large fictitious masses located at the area of structural changes. A low-frequency subset of these modes is then transformed into a set of structural modal coordinates with which the entire simulation is performed. These generalized coordinates and the associated oscillatory aerodynamic force coefficient matrices are used to construct an efficient time-domain, state-space model for a basic aeroelastic case. The time simulation can then be performed by simply changing the mass, stiffness, and damping coupling terms when structural changes occur. It is shown that the size of the aeroelastic model required for time simulation with large structural changes at a few apriori known locations is similar to that required for direct analysis of a single structural case. The method is applied to the simulation of an aeroelastic wind-tunnel model. The diverging oscillations are followed by the activation of a tip-ballast decoupling mechanism that stabilizes the system but may cause significant transient overshoots.

  5. Organotypic brain slice cultures of adult transgenic P301S mice--a model for tauopathy studies.

    Directory of Open Access Journals (Sweden)

    Agneta Mewes

    Full Text Available BACKGROUND: Organotypic brain slice cultures represent an excellent compromise between single cell cultures and complete animal studies, in this way replacing and reducing the number of animal experiments. Organotypic brain slices are widely applied to model neuronal development and regeneration as well as neuronal pathology concerning stroke, epilepsy and Alzheimer's disease (AD. AD is characterized by two protein alterations, namely tau hyperphosphorylation and excessive amyloid β deposition, both causing microglia and astrocyte activation. Deposits of hyperphosphorylated tau, called neurofibrillary tangles (NFTs, surrounded by activated glia are modeled in transgenic mice, e.g. the tauopathy model P301S. METHODOLOGY/PRINCIPAL FINDINGS: In this study we explore the benefits and limitations of organotypic brain slice cultures made of mature adult transgenic mice as a potential model system for the multifactorial phenotype of AD. First, neonatal (P1 and adult organotypic brain slice cultures from 7- to 10-month-old transgenic P301S mice have been compared with regard to vitality, which was monitored with the lactate dehydrogenase (LDH- and the MTT (3-(4,5-Dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide assays over 15 days. Neonatal slices displayed a constant high vitality level, while the vitality of adult slice cultures decreased significantly upon cultivation. Various preparation and cultivation conditions were tested to augment the vitality of adult slices and improvements were achieved with a reduced slice thickness, a mild hypothermic cultivation temperature and a cultivation CO(2 concentration of 5%. Furthermore, we present a substantial immunohistochemical characterization analyzing the morphology of neurons, astrocytes and microglia in comparison to neonatal tissue. CONCLUSION/SIGNIFICANCE: Until now only adolescent animals with a maximum age of two months have been used to prepare organotypic brain slices. The current study

  6. Adolescent Kawasaki disease: usefulness of 64-slice CT coronary angiography for follow-up investigation

    Energy Technology Data Exchange (ETDEWEB)

    Carbone, Iacopo; Cannata, David; Algeri, Emanuela; Galea, Nicola; Napoli, Alessandro; Catalano, Carlo; Passariello, Roberto; Francone, Marco [Sapienza University of Rome, Department of Radiological, Onchological and Anatomopathological Sciences, Policlinico Umberto I, Rome (Italy); De Zorzi, Andrea [Bambino Gesu Hospital, Cardiology Division, Rome (Italy); Bosco, Giovanna; D' Agostino, Rita [Sapienza University of Rome, Unit of Paediatric Cardiology, Policlinico Umberto I, Rome (Italy); Menezes, Leon [University College of London, Institute of Nuclear Medicine, London (United Kingdom)

    2011-09-15

    Kawasaki disease (KD) is a systemic vasculitis that mainly affects coronary arteries in children, and requires regular follow-up from the time of diagnosis. To evaluate the feasibility of 64-slice CT angiography (CTA) for follow-up of patients with KD using previously performed invasive catheter coronary angiography (CCA) as reference standard. The study group comprised 12 patients (age 17.6 {+-} 2.9 years, mean{+-}SD) with a diagnosis of KD and a previously performed CCA (interval, 32.6 {+-} 13.5 months) who underwent 64-slice cardiac CTA. The quality of the images for establishing the presence of coronary abnormalities was determined by two observers. The CTA findings were compared with those from the prior CCA. Adequate image quality was obtained in all patients. Mean effective dose for CTA was 6.56 {+-} 0.95 mSv. CTA allowed accurate identification, characterization and measurement of all coronary aneurysms (n = 32), stenoses (n = 3) and occlusions (n = 9) previously demonstrated by CCA. One patient with disease progression went on to have percutaneous coronary intervention. Coronary lesions were reliably evaluated by 64-slice CTA in the follow-up of compliant patients with KD, reducing the need for repeated diagnostic invasive CCA. Hence, in an adequately selected patient population, the role of CCA could be limited almost only to therapeutic procedures. (orig.)

  7. Analytical properties of time-of-flight PET data

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sanghee; Ahn, Sangtae; Quanzheng, Li; Leahy, Richard M [Signal and Image Processing Institute, University of Southern California, Los Angeles, CA 90089 (United States)], E-mail: leahy@sipi.usc.edu

    2008-06-07

    We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the 'bow-tie' property of the 2D Radon transform to the time-of-flight case. Second, we describe a new exact Fourier rebinning method, TOF-FOREX, based on the Fourier transform in the time-of-flight variable. We then combine TOF-FOREX rebinning with a direct extension of the projection slice theorem to TOF data, to perform fast 3D TOF PET image reconstruction. Finally, we illustrate these properties using simulated data.

  8. Analytical properties of time-of-flight PET data

    Science.gov (United States)

    Cho, Sanghee; Ahn, Sangtae; Li, Quanzheng; Leahy, Richard M.

    2008-06-01

    We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the 'bow-tie' property of the 2D Radon transform to the time-of-flight case. Second, we describe a new exact Fourier rebinning method, TOF-FOREX, based on the Fourier transform in the time-of-flight variable. We then combine TOF-FOREX rebinning with a direct extension of the projection slice theorem to TOF data, to perform fast 3D TOF PET image reconstruction. Finally, we illustrate these properties using simulated data.

  9. Analytical properties of time-of-flight PET data

    International Nuclear Information System (INIS)

    Cho, Sanghee; Ahn, Sangtae; Li Quanzheng; Leahy, Richard M

    2008-01-01

    We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the 'bow-tie' property of the 2D Radon transform to the time-of-flight case. Second, we describe a new exact Fourier rebinning method, TOF-FOREX, based on the Fourier transform in the time-of-flight variable. We then combine TOF-FOREX rebinning with a direct extension of the projection slice theorem to TOF data, to perform fast 3D TOF PET image reconstruction. Finally, we illustrate these properties using simulated data

  10. Analytical properties of time-of-flight PET data

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sanghee; Ahn, Sangtae; Li Quanzheng; Leahy, Richard M [Signal and Image Processing Institute, University of Southern California, Los Angeles, CA 90089 (United States)], E-mail: leahy@sipi.usc.edu

    2008-06-07

    We investigate the analytical properties of time-of-flight (TOF) positron emission tomography (PET) sinograms, where the data are modeled as line integrals weighted by a spatially invariant TOF kernel. First, we investigate the Fourier transform properties of 2D TOF data and extend the 'bow-tie' property of the 2D Radon transform to the time-of-flight case. Second, we describe a new exact Fourier rebinning method, TOF-FOREX, based on the Fourier transform in the time-of-flight variable. We then combine TOF-FOREX rebinning with a direct extension of the projection slice theorem to TOF data, to perform fast 3D TOF PET image reconstruction. Finally, we illustrate these properties using simulated data.

  11. Real-time inextensible surgical thread simulation.

    Science.gov (United States)

    Xu, Lang; Liu, Qian

    2018-03-27

    This paper discusses a real-time simulation method of inextensible surgical thread based on the Cosserat rod theory using position-based dynamics (PBD). The method realizes stable twining and knotting of surgical thread while including inextensibility, bending, twisting and coupling effects. The Cosserat rod theory is used to model the nonlinear elastic behavior of surgical thread. The surgical thread model is solved with PBD to achieve a real-time, extremely stable simulation. Due to the one-dimensional linear structure of surgical thread, the direct solution of the distance constraint based on tridiagonal matrix algorithm is used to enhance stretching resistance in every constraint projection iteration. In addition, continuous collision detection and collision response guarantee a large time step and high performance. Furthermore, friction is integrated into the constraint projection process to stabilize the twining of multiple threads and complex contact situations. Through comparisons with existing methods, the surgical thread maintains constant length under large deformation after applying the direct distance constraint in our method. The twining and knotting of multiple threads correspond to stable solutions to contact and friction forces. A surgical suture scene is also modeled to demonstrate the practicality and simplicity of our method. Our method achieves stable and fast simulation of inextensible surgical thread. Benefiting from the unified particle framework, the rigid body, elastic rod, and soft body can be simultaneously simulated. The method is appropriate for applications in virtual surgery that require multiple dynamic bodies.

  12. Mouse pancreas tissue slice culture facilitates long-term studies of exocrine and endocrine cell physiology in situ.

    Science.gov (United States)

    Marciniak, Anja; Selck, Claudia; Friedrich, Betty; Speier, Stephan

    2013-01-01

    Studies on pancreatic cell physiology rely on the investigation of exocrine and endocrine cells in vitro. Particularly, in the case of the exocrine tissue these studies have suffered from a reduced functional viability of acinar cells in culture. As a result not only investigations on dispersed acinar cells and isolated acini were limited in their potential, but also prolonged studies on pancreatic exocrine and endocrine cells in an intact pancreatic tissue environment were unfeasible. To overcome these limitations, we aimed to establish a pancreas tissue slice culture platform to allow long-term studies on exocrine and endocrine cells in the intact pancreatic environment. Mouse pancreas tissue slice morphology was assessed to determine optimal long-term culture settings for intact pancreatic tissue. Utilizing optimized culture conditions, cell specificity and function of exocrine acinar cells and endocrine beta cells were characterized over a culture period of 7 days. We found pancreas tissue slices cultured under optimized conditions to have intact tissue specific morphology for the entire culture period. Amylase positive intact acini were present at all time points of culture and acinar cells displayed a typical strong cell polarity. Amylase release from pancreas tissue slices decreased during culture, but maintained the characteristic bell-shaped dose-response curve to increasing caerulein concentrations and a ca. 4-fold maximal over basal release. Additionally, endocrine beta cell viability and function was well preserved until the end of the observation period. Our results show that the tissue slice culture platform provides unprecedented maintenance of pancreatic tissue specific morphology and function over a culture period for at least 4 days and in part even up to 1 week. This analytical advancement now allows mid -to long-term studies on the cell biology of pancreatic disorder pathogenesis and therapy in an intact surrounding in situ.

  13. Mouse pancreas tissue slice culture facilitates long-term studies of exocrine and endocrine cell physiology in situ.

    Directory of Open Access Journals (Sweden)

    Anja Marciniak

    Full Text Available Studies on pancreatic cell physiology rely on the investigation of exocrine and endocrine cells in vitro. Particularly, in the case of the exocrine tissue these studies have suffered from a reduced functional viability of acinar cells in culture. As a result not only investigations on dispersed acinar cells and isolated acini were limited in their potential, but also prolonged studies on pancreatic exocrine and endocrine cells in an intact pancreatic tissue environment were unfeasible. To overcome these limitations, we aimed to establish a pancreas tissue slice culture platform to allow long-term studies on exocrine and endocrine cells in the intact pancreatic environment. Mouse pancreas tissue slice morphology was assessed to determine optimal long-term culture settings for intact pancreatic tissue. Utilizing optimized culture conditions, cell specificity and function of exocrine acinar cells and endocrine beta cells were characterized over a culture period of 7 days. We found pancreas tissue slices cultured under optimized conditions to have intact tissue specific morphology for the entire culture period. Amylase positive intact acini were present at all time points of culture and acinar cells displayed a typical strong cell polarity. Amylase release from pancreas tissue slices decreased during culture, but maintained the characteristic bell-shaped dose-response curve to increasing caerulein concentrations and a ca. 4-fold maximal over basal release. Additionally, endocrine beta cell viability and function was well preserved until the end of the observation period. Our results show that the tissue slice culture platform provides unprecedented maintenance of pancreatic tissue specific morphology and function over a culture period for at least 4 days and in part even up to 1 week. This analytical advancement now allows mid -to long-term studies on the cell biology of pancreatic disorder pathogenesis and therapy in an intact surrounding in situ.

  14. Automatic slice identification in 3D medical images with a ConvNet regressor

    NARCIS (Netherlands)

    de Vos, Bob D.; Viergever, Max A.; de Jong, Pim A.; Išgum, Ivana

    2016-01-01

    Identification of anatomical regions of interest is a prerequisite in many medical image analysis tasks. We propose a method that automatically identifies a slice of interest (SOI) in 3D images with a convolutional neural network (ConvNet) regressor. In 150 chest CT scans two reference slices were

  15. Fluidized bed drying characteristics and modeling of ginger ( zingiber officinale) slices

    Science.gov (United States)

    Parlak, Nezaket

    2015-08-01

    In this study fluidized bed drying characteristics of ginger have been investigated. The effects of the fluidizing air temperature, velocity, humidity and bed height on the drying performance of ginger slices have been found. The experimental moisture loss data of ginger slices has been fitted to the eight thin layer drying models. Two-term model drying model has shown a better fit to the experimental data with R2 of 0.998 as compared to others.

  16. Drying of carrot slices in a triple pass solar dryer

    Directory of Open Access Journals (Sweden)

    Seshachalam Kesavan

    2017-01-01

    Full Text Available An indirect triple pass forced convection solar dryer was developed and its performance was evaluated for drying of carrot slices. The drying experiments were carried out under the meteorological conditions of Coimbatore city in India during the year 2016. The experimental set-up consists of a blower, triple pass packed bed air collector (using sand with wire mesh absorber plate, and a drying chamber. The air mass flow rate was optimized to 0.062 kg/s. The initial moisture content of the carrot slices was reduced from 87.5% (on wet basis to the final moisture content of 10% (wet basis in 6 h duration. The thin layer drying characteristics were analyzed using twelve mathematical models available in open literature. The results showed that the pick-up efficiency of the dryer was varied in the range between 14 and 43% with an average air collector thermal efficiency of 44% during the experimentation. The drying characteristics of carrot slices was predicted with good degree of accuracy using Wang and Singh drying model.

  17. Real-time simulation of ex-core nuclear instrumentation system

    International Nuclear Information System (INIS)

    Zhao Qiang; Zhang Zhijian; Cao Xinrong

    2005-01-01

    Real-time simulation of ex-core nuclear instrumentation system is an indispensable part of nuclear power plant (NPP) full-scope training simulator. The simulation method, which is based upon the theory of measurement, is introduced in the paper. The fitting formula between the measured data and the three-dimensional neutron flux distribution in the core is established. The fitting parameter is adjusted according to the reactor physical calculation or the experiment of power calibration. The simulation result shows that the method can simulate the ex-core neutron instrumentation system accurately in real-time and meets the needs of NPP full-scope training simulator. (authors)

  18. Time-Domain Simulation of RF Couplers

    International Nuclear Information System (INIS)

    Smithe, David; Carlsson, Johan; Austin, Travis

    2009-01-01

    We have developed a finite-difference time-domain (FDTD) fluid-like approach to integrated plasma-and-coupler simulation [1], and show how it can be used to model LH and ICRF couplers in the MST and larger tokamaks.[2] This approach permits very accurate 3-D representation of coupler geometry, and easily includes non-axi-symmetry in vessel wall, magnetic equilibrium, and plasma density. The plasma is integrated with the FDTD Maxwell solver in an implicit solve that steps over electron time-scales, and permits tenuous plasma in the coupler itself, without any need to distinguish or interface between different regions of vacuum and/or plasma. The FDTD algorithm is also generalized to incorporate a time-domain sheath potential [3] on metal structures within the simulation, to look for situations where the sheath potential might generate local sputtering opportunities. Benchmarking of the time-domain sheath algorithm has been reported in the references. Finally, the time-domain software [4] permits the use of particles, either as field diagnostic (test particles) or to self-consistently compute plasma current from the applied RF power.

  19. Multi-slice computed tomography-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma: a comparison with conventional microscopic transsphenoidal surgery.

    Science.gov (United States)

    Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei

    2015-11-01

    Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.

  20. Assessment of renal artery stenosis of transplanted kidney by time resolved gadolinium-enhanced three-dimensional MR angiography. Preliminary phantom study and clinical evaluation

    International Nuclear Information System (INIS)

    Hayano, Toshio

    2001-01-01

    The purpose of this study was to determine a suitable imaging parameters of time-resolved Gd-enhanced three-dimensional MR angiography (TRE3DMRA) for the evaluation of renal artery stenosis of transplanted kidneys and to investigate the usefulness of TRE3DMRA in 166 clinical cases. Source images were obtained 3dFLASH with zero-filling interpolation (turbo MRA) using Siemens Magneton 1.5T. Acrylate tubes with 6 mm inner diameter filled with diluted Gd-DTPA were used as special phantoms. In the tubes, 25%, 50%, and 75% stenosis were made for simulating arterial stenosis, respectively. According to our clinical experiences, we decided 10 seconds or less acquisition time to obtaining renal artery images without overlapping with renal veins. To determine slice thickness, the degrees of stenosis of the phantom images obtained 8-second acquisition time in variable slice thickness were independently interpreted with visual inspection by two experienced diagnostic radiologists. One hundred sixty-six patients underwent renal transplantation were evaluated clinically. Using a power injector, 0.1 mmol/kg Gd-DTPA was injected after the test scan with 1 ml Gd-DTPA for the determination of acquisition timing. MR images were obtained in the following imaging parameters; 4-mm slice thickness and 8-second acquisition time based on the results of phantom studies. Source images were noted in oblique coronal direction encompassing the entire renal arteries from iliac arteries to renal hili. Based on phantom study, slice thickness must be less than 4-mm to demonstrate the significant stenotic portion (>50%) of the phantom simulating transplanted renal artery. In 150 of 166 patients, excellent images of renal arteries were obtained without overlapping with renal veins. Causes of poor images were mainly inadequate timing of image acquisition. We can decide the imaging parameters of TRE3DMRA for the evaluation of renal artery stenosis of transplanted kidneys. Using these parameters, in 150

  1. Lipopolysaccharide does not alter small airway reactivity in mouse lung slices.

    Science.gov (United States)

    Donovan, Chantal; Royce, Simon G; Vlahos, Ross; Bourke, Jane E

    2015-01-01

    The bacterial endotoxin, lipopolysaccharide (LPS) has been associated with occupational airway diseases with asthma-like symptoms and in acute exacerbations of COPD. The direct and indirect effects of LPS on small airway reactivity have not been fully elucidated. We tested the hypothesis that both in vitro and in vivo LPS treatment would increase contraction and impair relaxation of mouse small airways. Lung slices were prepared from naïve Balb/C mice and cultured in the absence or presence of LPS (10 μg/ml) for up to 48 h for measurement of TNFα levels in conditioned media. Alternatively, mice were challenged with PBS or LPS in vivo once a day for 4 days for preparation of lung slices or for harvest of lungs for Q-PCR analysis of gene expression of pro-inflammatory cytokines and receptors involved in airway contraction. Reactivity of small airways to contractile agonists, methacholine and serotonin, and bronchodilator agents, salbutamol, isoprenaline and rosiglitazone, were assessed using phase-contrast microscopy. In vitro LPS treatment of slices increased TNFα release 6-fold but did not alter contraction or relaxation to any agonists tested. In vivo LPS treatment increased lung gene expression of TNFα, IL-1β and ryanodine receptor isoform 2 more than 5-fold. However there were no changes in reactivity in lung slices from these mice, even when also incubated with LPS ex vivo. Despite evidence of LPS-induced inflammation, neither airway hyperresponsiveness or impaired dilator reactivity were evident. The increase in ryanodine receptor isoform 2, known to regulate calcium signaling in vascular smooth muscle, warrants investigation. Since LPS failed to elicit changes in small airway reactivity in mouse lung slices following in vitro or in vivo treatment, alternative approaches are required to define the potential contribution of this endotoxin to altered small airway reactivity in human lung diseases.

  2. Lipopolysaccharide does not alter small airway reactivity in mouse lung slices.

    Directory of Open Access Journals (Sweden)

    Chantal Donovan

    Full Text Available The bacterial endotoxin, lipopolysaccharide (LPS has been associated with occupational airway diseases with asthma-like symptoms and in acute exacerbations of COPD. The direct and indirect effects of LPS on small airway reactivity have not been fully elucidated. We tested the hypothesis that both in vitro and in vivo LPS treatment would increase contraction and impair relaxation of mouse small airways. Lung slices were prepared from naïve Balb/C mice and cultured in the absence or presence of LPS (10 μg/ml for up to 48 h for measurement of TNFα levels in conditioned media. Alternatively, mice were challenged with PBS or LPS in vivo once a day for 4 days for preparation of lung slices or for harvest of lungs for Q-PCR analysis of gene expression of pro-inflammatory cytokines and receptors involved in airway contraction. Reactivity of small airways to contractile agonists, methacholine and serotonin, and bronchodilator agents, salbutamol, isoprenaline and rosiglitazone, were assessed using phase-contrast microscopy. In vitro LPS treatment of slices increased TNFα release 6-fold but did not alter contraction or relaxation to any agonists tested. In vivo LPS treatment increased lung gene expression of TNFα, IL-1β and ryanodine receptor isoform 2 more than 5-fold. However there were no changes in reactivity in lung slices from these mice, even when also incubated with LPS ex vivo. Despite evidence of LPS-induced inflammation, neither airway hyperresponsiveness or impaired dilator reactivity were evident. The increase in ryanodine receptor isoform 2, known to regulate calcium signaling in vascular smooth muscle, warrants investigation. Since LPS failed to elicit changes in small airway reactivity in mouse lung slices following in vitro or in vivo treatment, alternative approaches are required to define the potential contribution of this endotoxin to altered small airway reactivity in human lung diseases.

  3. Increased presevation of sliced mozzarella cheese by antimibrobial sachet incorporated with allyl isothiocyanate

    Directory of Open Access Journals (Sweden)

    Ana Clarissa dos Santos Pires

    2009-12-01

    Full Text Available There is an increasing tendency to add natural antimicrobials of plant origin into food. The objective of this work was to develop a microbial sachet incorporated with allyl isothiocyanate (AIT, a volatile compound of plant origin, and to test its efficiency against growth of yeasts and molds, Staphylococcus sp. and psychrotrophic bacteria on sliced mozzarella cheese. Another objective was to quantify the concentration of AIT in the headspace of cheese packaging. A reduction of 3.6 log cycles was observed in yeasts and molds counts in the mozzarella packed with the antimicrobial sachet over 15-day storage time. The sachet also showed an antibacterial effect on Staphylococcus sp., reducing 2.4 log cycles after 12-day storage. Psychrotrophic bacteria species were the most resistant to the antimicrobial action. The highest concentration of AIT (0.08µg.mL-1 inside the active packaging system was observed at the 6-day of storage at 12 ºC ± 2 ºC. At the end of the storage time, AIT concentration decreased to only 10% of the initial concentration. Active packaging containing antimicrobial sachet has a potential use for sliced mozzarella, with molds and yeasts being the most sensitive to the antimicrobial effects.

  4. CFD simulation of homogenisation time measured by radiotracers

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostik, M.; Jahoda, M.

    2004-01-01

    A methodology for CFD (Computational Fluid Dynamics) simulation of radiotracer experiments was suggested. The most important parts of the methodology for validation of CFD results by radiotracers are: a) successful simulation of tracer experiment by CFD code (numerical solution of tracer dispersion in a stirred tank), which results in tracer concentration field at several time intervals; b) post-process data treatment, which uses detection chain description and which enables to simulate the detector measurement of homogenisation time from the tracer concentration field evaluated by CFD code. (author)

  5. Metabolomics of Therapy Response in Preclinical Glioblastoma: A Multi-Slice MRSI-Based Volumetric Analysis for Noninvasive Assessment of Temozolomide Treatment

    Science.gov (United States)

    Arias-Ramos, Nuria; Ferrer-Font, Laura; Lope-Piedrafita, Silvia; Mocioiu, Victor; Julià-Sapé, Margarida; Pumarola, Martí; Arús, Carles; Candiota, Ana Paula

    2017-01-01

    Glioblastoma (GBM) is the most common aggressive primary brain tumor in adults, with a short survival time even after aggressive therapy. Non-invasive surrogate biomarkers of therapy response may be relevant for improving patient survival. Previous work produced such biomarkers in preclinical GBM using semi-supervised source extraction and single-slice Magnetic Resonance Spectroscopic Imaging (MRSI). Nevertheless, GBMs are heterogeneous and single-slice studies could prevent obtaining relevant information. The purpose of this work was to evaluate whether a multi-slice MRSI approach, acquiring consecutive grids across the tumor, is feasible for preclinical models and may produce additional insight into therapy response. Nosological images were analyzed pixel-by-pixel and a relative responding volume, the Tumor Responding Index (TRI), was defined to quantify response. Heterogeneous response levels were observed and treated animals were ascribed to three arbitrary predefined groups: high response (HR, n = 2), TRI = 68.2 ± 2.8%, intermediate response (IR, n = 6), TRI = 41.1 ± 4.2% and low response (LR, n = 2), TRI = 13.4 ± 14.3%, producing therapy response categorization which had not been fully registered in single-slice studies. Results agreed with the multi-slice approach being feasible and producing an inverse correlation between TRI and Ki67 immunostaining. Additionally, ca. 7-day oscillations of TRI were observed, suggesting that host immune system activation in response to treatment could contribute to the responding patterns detected. PMID:28524099

  6. Metabolomics of Therapy Response in Preclinical Glioblastoma: A Multi-Slice MRSI-Based Volumetric Analysis for Noninvasive Assessment of Temozolomide Treatment

    Directory of Open Access Journals (Sweden)

    Nuria Arias-Ramos

    2017-05-01

    Full Text Available Glioblastoma (GBM is the most common aggressive primary brain tumor in adults, with a short survival time even after aggressive therapy. Non-invasive surrogate biomarkers of therapy response may be relevant for improving patient survival. Previous work produced such biomarkers in preclinical GBM using semi-supervised source extraction and single-slice Magnetic Resonance Spectroscopic Imaging (MRSI. Nevertheless, GBMs are heterogeneous and single-slice studies could prevent obtaining relevant information. The purpose of this work was to evaluate whether a multi-slice MRSI approach, acquiring consecutive grids across the tumor, is feasible for preclinical models and may produce additional insight into therapy response. Nosological images were analyzed pixel-by-pixel and a relative responding volume, the Tumor Responding Index (TRI, was defined to quantify response. Heterogeneous response levels were observed and treated animals were ascribed to three arbitrary predefined groups: high response (HR, n = 2, TRI = 68.2 ± 2.8%, intermediate response (IR, n = 6, TRI = 41.1 ± 4.2% and low response (LR, n = 2, TRI = 13.4 ± 14.3%, producing therapy response categorization which had not been fully registered in single-slice studies. Results agreed with the multi-slice approach being feasible and producing an inverse correlation between TRI and Ki67 immunostaining. Additionally, ca. 7-day oscillations of TRI were observed, suggesting that host immune system activation in response to treatment could contribute to the responding patterns detected.

  7. The mitochondrial toxin, 3-nitropropionic acid, induces extracellular Zn2+ accumulation in rat hippocampus slices.

    Science.gov (United States)

    Wei, Guo; Hough, Christopher J; Sarvey, John M

    2004-11-11

    3-nitropropionic acid (3-NPA), a suicide inhibitor of succinate dehydrogenase (SDH; complex II), has been used to provide useful experimental models of Huntington's disease (HD) and "chemical hypoxia" in rodents. The trace ion Zn2+ has been shown to cause neurodegeneration. Employing real-time Newport Green fluorescence imaging of extracellular Zn2+, we found that 3-NPA (10-100 microM) caused a concentration-dependent increase in the concentration of extracellular Zn2+ ([Zn2+]o) in acute rat hippocampus slices. This increase in [Zn2+]o was abolished by 10 mM CaEDTA. The increase of [Zn2+]o was also accompanied by a rapid increase of cytoplasmic-free Zn2+ concentration ([Zn2+]i). The induction of Zn2+ release by 3-MPA in hippocampus slices points to a potential mechanism by which 3-NPA might induce neurodegeneration.

  8. A prospective study to determine the need for physical simulation following virtual simulation

    International Nuclear Information System (INIS)

    Valicenti, R.K.; Waterman, F.M.; Corn, B.W.; Sweet, J.; Curran, W.J.

    1996-01-01

    Purpose: Virtual simulation is CT based planning utilizing computed digitally reconstructed radiographs (DRRs) in a manner similar to conventional fluoroscopic simulation. However, conventional or physical simulation is still widely used to assure precise implementation of the devised plan. To evaluate the need for performing physical simulation, we prospectively studied patients undergoing virtual simulation who either had or did not have a subsequent physical simulation. Materials and Methods: From July, 1995 to February, 1996, 48 patients underwent conformal 4-field radiation therapy for prostate cancer using a commercial grade spiral CT simulator. All patients were immobilized in a foam body cast and positioned by using a fiducial laser marking system. Following prostate and seminal vesicle definition on a slice-by-slice basis, virtual simulation was performed. The isocenter defined by this process was marked on both the patient and the immobilization device before leaving the CT simulator room. The isocenter position of the devised plan was evaluated by three verification methods: physical simulation, first day treatment port filming, and port filming immediately following physical simulation. Simulator radiographs and port films were compared against DRRs for x, y, and z deviations of the isocenter. These deviations were used as a measure of the implementation precision achieved by each verification method. Results: Thirty-seven patients underwent physical simulation and first day port filming. Eleven had first day treatment verification films only and never had a physical simulation. A total of 79 simulator radiographs and 126 first day treatment port films were reviewed. The tabulation of all deviations is as follows: There was significantly more setup error (≥ 5 mm) observed when the devised treatment was implemented in the treatment room as opposed to the physical simulator. The physical simulator did not lead to a significant reduction in setup error

  9. Operating system for a real-time multiprocessor propulsion system simulator

    Science.gov (United States)

    Cole, G. L.

    1984-01-01

    The success of the Real Time Multiprocessor Operating System (RTMPOS) in the development and evaluation of experimental hardware and software systems for real time interactive simulation of air breathing propulsion systems was evaluated. The Real Time Multiprocessor Operating System (RTMPOS) provides the user with a versatile, interactive means for loading, running, debugging and obtaining results from a multiprocessor based simulator. A front end processor (FEP) serves as the simulator controller and interface between the user and the simulator. These functions are facilitated by the RTMPOS which resides on the FEP. The RTMPOS acts in conjunction with the FEP's manufacturer supplied disk operating system that provides typical utilities like an assembler, linkage editor, text editor, file handling services, etc. Once a simulation is formulated, the RTMPOS provides for engineering level, run time operations such as loading, modifying and specifying computation flow of programs, simulator mode control, data handling and run time monitoring. Run time monitoring is a powerful feature of RTMPOS that allows the user to record all actions taken during a simulation session and to receive advisories from the simulator via the FEP. The RTMPOS is programmed mainly in PASCAL along with some assembly language routines. The RTMPOS software is easily modified to be applicable to hardware from different manufacturers.

  10. The physiology of rodent beta-cells in pancreas slices.

    Science.gov (United States)

    Rupnik, M

    2009-01-01

    Beta-cells in pancreatic islets form complex syncytia. Sufficient cell-to-cell electrical coupling seems to ensure coordinated depolarization pattern and insulin release that can be further modulated by rich innervation. The complex structure and coordinated action develop after birth during fast proliferation of the endocrine tissue. These emergent properties can be lost due to various reasons later in life and can lead to glucose intolerance and diabetes mellitus. Pancreas slice is a novel method of choice to study the physiology of beta-cells still embedded in their normal cellulo-social context. I present major advantages, list drawbacks and provide an overview on recent advances in our understanding of the physiology of beta-cells using the pancreas slice approach.

  11. Effect of simultaneous infrared dry-blanching and dehydration on quality characteristics of carrot slices

    Science.gov (United States)

    This study investigated the effects of various processing parameters on carrot slices exposed to infrared (IR) radiation heating for achieving simultaneous infrared dry-blanching and dehydration (SIRDBD). The investigated parameters were product surface temperature, slice thickness and processing ti...

  12. Differential patterns of injury to the proximal tubule of renal cortical slices following in vitro exposure to mercuric chloride, potassium dichromate, or hypoxic conditions.

    Science.gov (United States)

    Ruegg, C E; Gandolfi, A J; Nagle, R B; Brendel, K

    1987-09-15

    The innate susceptibility of renal cell types to these agents was investigated using precision-cut rabbit renal cortical slices made perpendicular to the cortical-papillary axis. Slices were incubated in DME/F12 medium containing 10 microM, 100 microM, or 1 mM concentrations of either metal for 12 hr or in Krebs-Hepes buffer gassed with nitrogen (100%) for 0.75 to 5 hr of hypoxic exposure. To simulate postischemic reperfusion, some slices were transferred to vessels gassed with oxygen after an initial hypoxic period. Mercuric chloride (100 microM) exposure resulted in damage to the straight regions of proximal tubules by 12 hr leaving convoluted regions unaffected. Hypoxia (2.25 hr) and potassium dichromate (100 microM for 12 hr) both caused injury to the convoluted proximal tubules without affecting straight proximal tubular regions. Mercury concentrations of 10 microM and 1 mM had no effect or injured all cell types within the slice, respectively. Similar results were observed for hypoxic periods less than 1.5 hr or greater than 3 hr of exposure. Potassium dichromate had no measurable affect at 10 microM, but at 1 mM focal lesions were observed after 4 hr of exposure, and by 12 hr all cell types within the slice were affected. Intracellular potassium content normalized to DNA correlated well, but always preceded the pathological lesions observed. These results demonstrate that injury to specific regions of the proximal tubule by these agents relates to an innate susceptibility of the intoxicated cell type independent of physiologic feedback or blood delivery patterns proposed as mechanisms of selective injury from in vivo studies.

  13. Mathematical modeling of hot air/electrohydrodynamic (EHD) drying kinetics of mushroom slices

    International Nuclear Information System (INIS)

    Taghian Dinani, Somayeh; Hamdami, Nasser; Shahedi, Mohammad; Havet, Michel

    2014-01-01

    Highlights: • Hot air/EHD drying behavior of thin layer mushroom slices was evaluated. • A new empirical model was proposed for drying kinetics modeling of mushroom slices. • The new model presents excellent predictions for hot air/EHD drying of mushroom. - Abstract: Researches about mathematical modeling of electrohydrodynamic (EHD) drying are rare. In this study, hot air combined with electrohydrodynamic (EHD) drying behavior of thin layer mushroom slices was evaluated in a laboratory scale dryer at voltages of 17, 19, and 21 kV and electrode gaps of 5, 6, and 7 cm. The drying curves were fitted to ten different mathematical models (Newton, Page, Modified Page, Henderson and Pabis, Logarithmic, Two-term exponential, Midilli and Kucuk, Wang and Singh, Weibull and Parabolic models) and a proposed new empirical model to select a suitable drying equation for drying mushroom slices in a hot air combined with EHD dryer. Coefficients of the models were determined by non-linear regression analysis and the models were compared based on their coefficient of determination (R 2 ), sum of square errors (SSE) and root mean square error (RMSE) between experimental and predicted moisture ratios. According to the results, the proposed model that contains only three parameters provided the best fit with the experimental data. It was closely followed by the Midilli and Kucuk model that contains four parameters. Therefore, the proposed model can present comfortable usage and excellent predictions for the moisture content changes of mushroom slices in the hot air combined with EHD drying system

  14. Brain Slice Staining and Preparation for Three-Dimensional Super-Resolution Microscopy

    Science.gov (United States)

    German, Christopher L.; Gudheti, Manasa V.; Fleckenstein, Annette E.; Jorgensen, Erik M.

    2018-01-01

    Localization microscopy techniques – such as photoactivation localization microscopy (PALM), fluorescent PALM (FPALM), ground state depletion (GSD), and stochastic optical reconstruction microscopy (STORM) – provide the highest precision for single molecule localization currently available. However, localization microscopy has been largely limited to cell cultures due to the difficulties that arise in imaging thicker tissue sections. Sample fixation and antibody staining, background fluorescence, fluorophore photoinstability, light scattering in thick sections, and sample movement create significant challenges for imaging intact tissue. We have developed a sample preparation and image acquisition protocol to address these challenges in rat brain slices. The sample preparation combined multiple fixation steps, saponin permeabilization, and tissue clarification. Together, these preserve intracellular structures, promote antibody penetration, reduce background fluorescence and light scattering, and allow acquisition of images deep in a 30 μm thick slice. Image acquisition challenges were resolved by overlaying samples with a permeable agarose pad and custom-built stainless steel imaging adapter, and sealing the imaging chamber. This approach kept slices flat, immobile, bathed in imaging buffer, and prevented buffer oxidation during imaging. Using this protocol, we consistently obtained single molecule localizations of synaptic vesicle and active zone proteins in three-dimensions within individual synaptic terminals of the striatum in rat brain slices. These techniques may be easily adapted to the preparation and imaging of other tissues, substantially broadening the application of super-resolution imaging. PMID:28924666

  15. Excitotoxic effects of non-NMDA receptor agonists in organotypic corticostriatal slice cultures

    DEFF Research Database (Denmark)

    Kristensen, B W; Noraberg, J; Jakobsen, B

    1999-01-01

    of the cytosolic enzyme lactate dehydrogenase (LDH) into the culture medium and loss of glutamic acid decarboxylase (GAD) activity in the tissue. Histological sections were also stained by the fluorescent dye Fluoro-Jade (FJ), for degenerating neurons and by immunocytochemical staining for gamma-aminobutyric acid...... density of Fluoro-Jade staining, (3) loss of GAD-activity in tissue homogenates, and (4) loss of GABA-immunostained neurons. We conclude that both differences between compounds (AMPA vs. KA) and brain areas (striatum vs. cortex) can be demonstrated in corticostriatal slice cultures, which in conjunction...... in corticostriatal slice cultures. The purpose was to examine the feasibility of these cultures for excitotoxic studies, and to demonstrate possible differential excitotoxic effects of KA and AMPA on striatal and cortical neurons. Slices of dorsolateral striatum with overlying neocortex were obtained from neonatal...

  16. Robust Transmission of H.264/AVC Streams Using Adaptive Group Slicing and Unequal Error Protection

    Science.gov (United States)

    Thomos, Nikolaos; Argyropoulos, Savvas; Boulgouris, Nikolaos V.; Strintzis, Michael G.

    2006-12-01

    We present a novel scheme for the transmission of H.264/AVC video streams over lossy packet networks. The proposed scheme exploits the error-resilient features of H.264/AVC codec and employs Reed-Solomon codes to protect effectively the streams. A novel technique for adaptive classification of macroblocks into three slice groups is also proposed. The optimal classification of macroblocks and the optimal channel rate allocation are achieved by iterating two interdependent steps. Dynamic programming techniques are used for the channel rate allocation process in order to reduce complexity. Simulations clearly demonstrate the superiority of the proposed method over other recent algorithms for transmission of H.264/AVC streams.

  17. The Atmospheric Chemistry and Climate Model Intercomparison Project (ACCMIP): Overview and Description of Models, Simulations and Climate Diagnostics

    Science.gov (United States)

    Lamarque, J.-F.; Shindell, D. T.; Naik, V.; Plummer, D.; Josse, B.; Righi, M.; Rumbold, S. T.; Schulz, M.; Skeie, R. B.; Strode, S.; hide

    2013-01-01

    The Atmospheric Chemistry and Climate Model Intercomparison Project (ACCMIP) consists of a series of time slice experiments targeting the long-term changes in atmospheric composition between 1850 and 2100, with the goal of documenting composition changes and the associated radiative forcing. In this overview paper, we introduce the ACCMIP activity, the various simulations performed (with a requested set of 14) and the associated model output. The 16 ACCMIP models have a wide range of horizontal and vertical resolutions, vertical extent, chemistry schemes and interaction with radiation and clouds. While anthropogenic and biomass burning emissions were specified for all time slices in the ACCMIP protocol, it is found that the natural emissions are responsible for a significant range across models, mostly in the case of ozone precursors. The analysis of selected present-day climate diagnostics (precipitation, temperature, specific humidity and zonal wind) reveals biases consistent with state-of-the-art climate models. The model-to- model comparison of changes in temperature, specific humidity and zonal wind between 1850 and 2000 and between 2000 and 2100 indicates mostly consistent results. However, models that are clear outliers are different enough from the other models to significantly affect their simulation of atmospheric chemistry.

  18. Investigation of influence of 16-slice spiral CT electrocardiogram-controlled dose modulation on exposure dosage and image quality of cardiac CT imaging under simulated fluctuant heart rate

    International Nuclear Information System (INIS)

    Yin Yan; Chen Jie; Chai Weiming; Hua Jia; Gao Na; Xu Jianrong; Shen Yun

    2008-01-01

    Objective: To investigate the influence of electrocardiogram (ECG)-controlled dose modulation on exposure dosage and image quality of cardiac CT imaging in a cardiac phantom with simulated fluctuant heart rate. Methods: The basal heart rate of the cardiac pulsating phantom was set as 60 bpm, the experimental situations were divided as 6 groups according to different heart rates. The cardiac imaging was performed on the cardiac phantom when the ECG-controlled dose modulation was firstly turned off. The exposure dosage of each scan sequence was documented. The standard deviation of the CT values of the phantom was measured on the central slice after coronal reformation of the raw data. The quality of 2D and 3D images were scored. Then cardiac imaging was performed when ECG modulation was on and set as four groups according to different modulation parameters. All the data were documented as before. The results from the five groups with and without ECG modulation current were analyzed by F test and comparative rank sum test using the statistical software SPSS 10.0. Results: Statistical analysis showed no significant difference (P>0.05) between the SNR of images (SD value was 27.78 and 26.30) from the groups that full mA output at wide reconstruction phase (69%-99%) when the heart rate was fluctuant(≥7.5 bpm). There was also no significant difference (P>0.05) between the quality of the 2D and 3D images. But there was a significant difference (P 12.5 bpm, the exposure dosage would increase obviously (from 0.6 to 1.7 mSv). Conclusion: For cardiac imaging with 16-slice row CT, the application of ECG modulated current can effectively reduce the exposure dosage without compromising the image quality even if heart rate was fluctuant. (authors)

  19. Towards Real Time Simulation of Ship-Ship Interaction

    DEFF Research Database (Denmark)

    Lindberg, Ole; Bingham, Harry B.; Engsig-Karup, Allan Peter

    2012-01-01

    We present recent and preliminary work directed towards the development of a simplified, physics-based model for improved simulation of ship-ship interaction that can be used for both analysis and real-time computing (i.e. with real-time constraints due to visualization). The goal is to implement...... accurate (realistic) and much faster ship-wave and ship-ship simulations than are currently possible. The coupling of simulation with visualization should improve the visual experience such that it can be perceived as more realistic in training. Today the state-of-art in real-time ship-ship interaction...... is for efficiency reasons and time-constraints in visualization based on model experiments in towing tanks and precomputed force tables. We anticipate that the fast, and highly parallel, algorithm described by Engsig-Karup et al. [2011] for execution on affordable modern high-throughput Graphics Processing Units...

  20. Biocompatibility of silicon-based arrays of electrodes coupled to organotypic hippocampal brain slice cultures

    DEFF Research Database (Denmark)

    Kristensen, Bjarne Winther; Noraberg, J; Thiébaud, P

    2001-01-01

    by Nissl staining, Timm sulphide silver-staining, microtubule-associated protein 2 (MAP2) and glial fibrillary acidic protein (GFAP) immunostaining, the slice cultures grown on chips did not differ from conventionally grown slice cultures. Neither were there any signs of astrogliosis or neurodegeneration...

  1. GUMICS4 Synthetic and Dynamic Simulations of the ECLAT Project

    Science.gov (United States)

    Facsko, G.; Palmroth, M. M.; Gordeev, E.; Hakkinen, L. V.; Honkonen, I. J.; Janhunen, P.; Sergeev, V. A.; Kauristie, K.; Milan, S. E.

    2012-12-01

    The European Commission funded the European Cluster Assimilation Techniques (ECLAT) project as a collaboration of five leader European universities and research institutes. A main contribution of the Finnish Meteorological Institute (FMI) is to provide a wide range of global MHD runs with the Grand Unified Magnetosphere Ionosphere Coupling simulation (GUMICS). The runs are divided in two categories: synthetic runs investigating the extent of solar wind drivers that can influence magnetospheric dynamics, as well as dynamic runs using measured solar wind data as input. Here we consider the first set of runs with synthetic solar wind input. The solar wind density, velocity and the interplanetary magnetic field had different magnitudes and orientations; furthermore two F10.7 flux values were selected for solar radiation minimum and maximum values. The solar wind parameter values were constant such that a constant stable solution was archived. All configurations were run several times with three different (-15°, 0°, +15°) tilt angles in the GSE X-Z plane. The Cray XT supercomputer of the FMI provides a unique opportunity in global magnetohydrodynamic simulation: running the GUMICS-4 based on one year real solar wind data. Solar wind magnetic field, density, temperature and velocity data based on Advanced Composition Explorer (ACE) and WIND measurements are downloaded from the OMNIWeb open database and a special input file is created for each Cluster orbit. All data gaps are replaced with linear interpolations between the last and first valid data values before and after the data gap. Minimum variance transformation is applied for the Interplanetary Magnetic Field data to clean and avoid the code of divergence. The Cluster orbits are divided into slices allowing parallel computation and each slice has an average tilt angle value. The file timestamps start one hour before the perigee to provide time for building up a magnetosphere in the simulation space. The real

  2. Clinical application of multi-slice helical CT volumetric scanning in lumber spine

    International Nuclear Information System (INIS)

    Wang Ling; Ge Yinghui; Zhu Shaocheng; Zhang Ming; Cheng Tianming; Lei Zhidan; Lv Chuanjian; Sun Xiaoping; Wu Minghui; Guo Ying; Ma Qianli; Wen Zeying

    2008-01-01

    Objective: To evaluate the clinical application value of multi-slice helical CT volumetric (VH) scanning in lumber spine. Methods: One thousand of patients with back and leg pain who underwent CT examinations were selected as subjects. We simulated the traditional protocol of single-slice(SS) discrete scanning for L3/4, L4/5, and L5/S1 intervertebral discs. The VH scanning mode was performed with 120 kV, 210 mAs, pitch of 1.5 and coverage of 97.5 mm. The simulated SS scanning mode was performed with 120 kV, 240 mAs and coverage of 45.0 mm. The diagnostic outcomes and the radiation doses were compared between the two scanning modes. Two groups doctors observed ten terms, including the osseous spinal stenosis, narrowed intervertebral space and so on in two scanning modes respectively. Then consistency analysis of the data was carded out. Results: The VH scanning mode showed far more features than the SS mode. The detection rates of the VH mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, narrowed lateral recess, vertebral lesion, hypertrophy of L5 transverse process, abnormal direction of facet, facet degeneration, lumbar spondyloschisis, and paraspinal soft tissue were 11.8% (n=118), 38.5% (n=385), 9.3% (n=93), 46.8% (n=468), 31.4% (n=314), 5.7% (n= 57), 25.4% (n=254), 49.7% (n=497), 9.9% (n=99), and 0.6% (n=6) respectively, while the detection rates of the SS mode in ten terms were 5.6% (n=56), 0, 0.6% (n=6), 27.9% (n=279), 22.4% (n=224), 1.2% (n=12), 16.7% (n=167), 37.2% (n=372), 0.5% (n=5), and 0.2% (n=2) respectively. The difference between the two groups had statistically significance (average P 0.05). The detection rates of the VH mode were higher than the SS mode in the osseous spinal stenosis, narrowed intervertebral space, herniated nucleus pulposus, lumbar spondyloschisis, being 6.2% (n=62), 38.5% (n=385), 8.7% (n=87), and 9.4% (n=94), respectively. In addition, VH mode only partially showed the articular

  3. A brain slice bath for physiology and compound microscopy, with dual-sided perifusion.

    Science.gov (United States)

    Heyward, P M

    2010-12-01

    Contemporary in vitro brain slice studies can employ compound microscopes to identify individual neurons or their processes for physiological recording or imaging. This requires that the bath used to maintain the tissue fits within the working distances of a water-dipping objective and microscope condenser. A common means of achieving this is to maintain thin tissue slices on the glass floor of a recording bath, exposing only one surface of the tissue to oxygenated bathing medium. Emerging evidence suggests that physiology can be compromised by this approach. Flowing medium past both sides of submerged brain slices is optimal, but recording baths utilizing this principle are not readily available for use on compound microscopes. This paper describes a tissue bath designed specifically for microscopy and physiological recording, in which temperature-controlled medium flows past both sides of the slices. A particular feature of this design is the use of concentric mesh rings to support and transport the live tissue without mechanical disturbance. The design is also easily adapted for use with thin acute slices, cultured slices, and acutely dispersed or cultured cells maintained either on cover slips or placed directly on the floor of the bath. The low profile of the bath provides a low angle of approach for electrodes, and allows use of standard condensers, nosepieces and water-dipping objective lenses. If visualization of individual neurons is not required, the bath can be mounted on a simple stand and used with a dissecting microscope. Heating is integral to the bath, and any temperature controller capable of driving a resistive load can be used. The bath is robust, readily constructed and requires minimal maintenance. Full construction and operation details are given. © 2010 The Author Journal of Microscopy © 2010 The Royal Microscopical Society.

  4. Evaluation of solitary pulmonary metastasis of extrathoracic tumor with thin-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro; Nomura, Ikuo; Noda, Kazumasa; Yamagata, Tatushi; Tajiri, Michihiko; Ishibashi, Makoto; Kameda, Youichi [Kanagawa Cancer Center, Yokohama (Japan)

    1995-10-01

    Thin-slice computed tomography (CT) images were compared with pathological findings in 9 specimens of solitary pulmonary nodules, which had been pathologically diagnosed as pulmonary metastasis of extrathoracic tumor. The thin-slice CT images were 2 mm-thick images reconstructed using a TCT-900S, HELIX (Toshiba, Tokyo) and examined at two different window and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT images. According to the image findings, the internal structure was of the solid-density type in every case, and the margin showed spiculation in 22%, notching in 67% and pleural indentation in 89%. Regarding the relationship between the pulmonary vessels and tumors, plural vascular involvement was revealed in every case. Thus, it was difficult to distinguish solitary pulmonary metastasis of extrathoracic tumor from primary lung cancer based on the thin-slice CT images. For some solitary pulmonary metastasis of extrathoracic tumor, a comprehensive diagnostic approach taking both the anamnesis and pathological findings into consideration was required. (author).

  5. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    Energy Technology Data Exchange (ETDEWEB)

    Favazza, C; Yu, L; Leng, S; McCollough, C [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  6. TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

    International Nuclear Information System (INIS)

    Favazza, C; Yu, L; Leng, S; McCollough, C

    2015-01-01

    Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project

  7. Stimulation of estradiol biosynthesis by tributyltin in rat hippocampal slices.

    Science.gov (United States)

    Munetsuna, Eiji; Hattori, Minoru; Yamazaki, Takeshi

    2014-01-01

    Hippocampal functions are influenced by steroid hormones, such as testosterone and estradiol. It has been demonstrated that hippocampus-derived steroid hormones play important roles in neuronal protection and synapse formation. Our research groups have demonstrated that estradiol is de novo synthesized in the rat hippocampus. However, the mechanism(s) regulating this synthesis remains unclear. It has been reported that tributyltin, an environmental pollutant, binds to the retinoid X receptor (RXR) and modifies estrogen synthesis in human granulosa-like tumor cells. This compound can penetrate the blood brain barrier, and tends to accumulate in the brain. Based on these facts, we hypothesized that tributyltin could influence the hippocampal estradiol synthesis. A concentration of 0.1 μM tributyltin induced an increase in the mRNA content of P450(17α) and P450arom in hippocampal slices, as determined using real-time PCR. The transcript levels of other steroidogenic enzymes and a steroidogenic acute regulatory protein were not affected. The estradiol level in rat hippocampal slices was subsequently determined using a radioimmunoassay. We found that the estradiol synthesis was stimulated by ∼2-fold following a 48-h treatment with 0.1 μM tributyltin, and this was accompanied by transcriptional activation of P450(17α) and P450arom. Tributyltin stimulated de novo hippocampal estradiol synthesis by modifying the transcription of specific steroidogenic enzymes.

  8. Simultaneous multislice magnetic resonance fingerprinting (SMS-MRF) with direct-spiral slice-GRAPPA (ds-SG) reconstruction.

    Science.gov (United States)

    Ye, Huihui; Cauley, Stephen F; Gagoski, Borjan; Bilgic, Berkin; Ma, Dan; Jiang, Yun; Du, Yiping P; Griswold, Mark A; Wald, Lawrence L; Setsompop, Kawin

    2017-05-01

    To develop a reconstruction method to improve SMS-MRF, in which slice acceleration is used in conjunction with highly undersampled in-plane acceleration to speed up MRF acquisition. In this work two methods are employed to efficiently perform the simultaneous multislice magnetic resonance fingerprinting (SMS-MRF) data acquisition and the direct-spiral slice-GRAPPA (ds-SG) reconstruction. First, the lengthy training data acquisition is shortened by employing the through-time/through-k-space approach, in which similar k-space locations within and across spiral interleaves are grouped and are associated with a single set of kernel. Second, inversion recovery preparation (IR prepped), variable flip angle (FA), and repetition time (TR) are used for the acquisition of the training data, to increase signal variation and to improve the conditioning of the kernel fitting. The grouping of k-space locations enables a large reduction in the number of kernels required, and the IR-prepped training data with variable FA and TR provide improved ds-SG kernels and reconstruction performance. With direct-spiral slice-GRAPPA, tissue parameter maps comparable to that of conventional MRF were obtained at multiband (MB) = 3 acceleration using t-blipped SMS-MRF acquisition with 32-channel head coil at 3 Tesla (T). The proposed reconstruction scheme allows MB = 3 accelerated SMS-MRF imaging with high-quality T 1 , T 2 , and off-resonance maps, and can be used to significantly shorten MRF acquisition and aid in its adoption in neuro-scientific and clinical settings. Magn Reson Med 77:1966-1974, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Time-based MRPC detector response simulations for the CBM time-of-flight system

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Christian; Herrmann, Norbert [Physikalisches Institut und Fakultaet fuer Physik und Astronomie, Ruprecht-Karls-Universitaet Heidelberg (Germany); Collaboration: CBM-Collaboration

    2016-07-01

    The design goal of the future Compressed Baryonic Matter (CBM) experiment is to measure rare probes of dense strongly interacting matter with an unprecedented accuracy. Target interaction rates of up to 10 MHz need to be processed by the detector. The time-of-flight (TOF) wall of CBM which should provide hadron identification at particle fluxes of up to a few tens of kHz/cm{sup 2} is composed of high-resolution timing multi-gap resistive plate chambers (MRPCs). Due to the self-triggered digitization and readout scheme of CBM comprising online event reconstruction preparatory Monte Carlo (MC) transport and response simulations including the MRPC array need to be carried out in a time-based fashion. While in an event-based simulation mode interference between MC tracks in a detector volume owing to rate effects or electronics dead time is confined to a single event, time-based response simulations need to take into account track pile-up and interference across events. A proposed time-based digitizer class for CBM-TOF within the CbmRoot software framework is presented.

  10. Toward real-time regional earthquake simulation of Taiwan earthquakes

    Science.gov (United States)

    Lee, S.; Liu, Q.; Tromp, J.; Komatitsch, D.; Liang, W.; Huang, B.

    2013-12-01

    We developed a Real-time Online earthquake Simulation system (ROS) to simulate regional earthquakes in Taiwan. The ROS uses a centroid moment tensor solution of seismic events from a Real-time Moment Tensor monitoring system (RMT), which provides all the point source parameters including the event origin time, hypocentral location, moment magnitude and focal mechanism within 2 minutes after the occurrence of an earthquake. Then, all of the source parameters are automatically forwarded to the ROS to perform an earthquake simulation, which is based on a spectral-element method (SEM). We have improved SEM mesh quality by introducing a thin high-resolution mesh layer near the surface to accommodate steep and rapidly varying topography. The mesh for the shallow sedimentary basin is adjusted to reflect its complex geometry and sharp lateral velocity contrasts. The grid resolution at the surface is about 545 m, which is sufficient to resolve topography and tomography data for simulations accurate up to 1.0 Hz. The ROS is also an infrastructural service, making online earthquake simulation feasible. Users can conduct their own earthquake simulation by providing a set of source parameters through the ROS webpage. For visualization, a ShakeMovie and ShakeMap are produced during the simulation. The time needed for one event is roughly 3 minutes for a 70 sec ground motion simulation. The ROS is operated online at the Institute of Earth Sciences, Academia Sinica (http://ros.earth.sinica.edu.tw/). Our long-term goal for the ROS system is to contribute to public earth science outreach and to realize seismic ground motion prediction in real-time.

  11. Finite-time thermodynamics and simulated annealing

    International Nuclear Information System (INIS)

    Andresen, B.

    1989-01-01

    When the general, global optimization technique simulated annealing was introduced by Kirkpatrick et al. (1983), this mathematical algorithm was based on an analogy to the statistical mechanical behavior of real physical systems like spin glasses, hence the name. In the intervening span of years the method has proven exceptionally useful for a great variety of extremely complicated problems, notably NP-problems like the travelling salesman, DNA sequencing, and graph partitioning. Only a few highly optimized heuristic algorithms (e.g. Lin, Kernighan 1973) have outperformed simulated annealing on their respective problems (Johnson et al. 1989). Simulated annealing in its current form relies only on the static quantity 'energy' to describe the system, whereas questions of rate, as in the temperature path (annealing schedule, see below), are left to intuition. We extent the connection to physical systems and take over further components from thermodynamics like ensemble, heat capacity, and relaxation time. Finally we refer to finite-time thermodynamics (Andresen, Salomon, Berry 1984) for a dynamical estimate of the optimal temperature path. (orig.)

  12. Software framework developed for the slice test of the ATLAS endcap muon trigger system

    CERN Document Server

    Komatsu, S; Ishida, Y; Tanaka, K; Hasuko, K; Kano, H; Matsumoto, Y; Yakamura, Y; Sakamoto, H; Ikeno, M; Nakayoshi, K; Sasaki, O; Yasu, Y; Hasegawa, Y; Totsuka, M; Tsuji, S; Maeno, T; Ichimiya, R; Kurashige, H

    2002-01-01

    A sliced system test of the ATLAS end cap muon level 1 trigger system has been done in 2001 and 2002 separately. We have developed an own software framework for property and run controls for the slice test in 2001. The system is described in C++ throughout. The multi-PC control system is accomplished using the CORBA system. We have then restructured the software system on top of the ATLAS online software framework, and used this one for the slice test in 2002. In this report we discuss two systems in detail with emphasizing the module property configuration and run control. (8 refs).

  13. Hyperexcitability and cell loss in kainate-treated hippocampal slice cultures

    DEFF Research Database (Denmark)

    Benedikz, Eirikur; Casaccia-Bonnefil, P; Stelzer, A

    1993-01-01

    Loss of hippocampal interneurons has been reported in patients with severe temporal lobe epilepsy and in animals treated with kainate. We investigated the relationship between KA induced epileptiform discharge and loss of interneurons in hippocampal slice cultures. Application of KA (1 micro......M) produced reversible epileptiform discharge without neurotoxicity. KA (5 microM), in contrast, produced irreversible epileptiform discharge and neurotoxicity, suggesting that the irreversible epileptiform discharge was required for the neuronal loss. Loss of CA3 pyramidal cells and parvalbumin......-like immunoreactive (PV-I) interneurons preceded loss of somatostatin-like immunoreactive (SS-I) interneurons suggesting a different time course of KA neurotoxicity in these subpopulations of interneurons....

  14. Real-time dynamic simulator for the Topaz II reactor power system

    International Nuclear Information System (INIS)

    Kwok, K.S.

    1994-01-01

    A dynamic simulator of the TOPAZ II reactor system has been developed for the Nuclear Electric Propulsion Space Test Program. The simulator is a self-contained IBM-PC compatible based system that executes at a speed faster than real-time. The simulator combines first-principle modeling and empirical correlations in its algorithm to attain the modeling accuracy and computational through-put that are required for real-time execution. The overall execution time of the simulator for each time step is 15 ms when no data is written to the disk, and 18 ms when nine double precision data points are written to the disk once in every time step. The simulation program has been tested and it is able to handle a step decrease of $8 worth of reactivity. It also provides simulation of fuel, emitter, collector, stainless steel, and ZrH moderator failures. Presented in this paper are the models used in the calculations, a sample simulation session, and a discussion of the performance and limitations of the simulator. The simulator has been found to provide realistic real-time dynamic response of the TOPAZ II reactor system under both normal and causality conditions

  15. Mathematical modeling of dehydration of 'Fuji' and 'Gala' apples slices using infrared

    Directory of Open Access Journals (Sweden)

    Emílio de Souza Santos

    2011-09-01

    Full Text Available The objective of this work was to determine and model the infrared dehydration curves of apple slices - Fuji and Gala varieties. The slices were dehydrated until constant mass, in a prototype dryer with infrared heating source. The applied temperatures ranged from 50 to 100 °C. Due to the physical characteristics of the product, the dehydration curve was divided in two periods, constant and falling, separated by the critical moisture content. A linear model was used to describe the constant dehydration period. Empirical models traditionally used to model the drying behavior of agricultural products were fitted to the experimental data of the falling dehydration period. Critical moisture contents of 2.811 and 3.103 kgw kgs-1 were observed for the Fuji and Gala varieties, respectively. Based on the results, it was concluded that the constant dehydration rates presented a direct relationship with the temperature; thus, it was possible to fit a model that describes the moisture content variation in function of time and temperature. Among the tested models, which describe the falling dehydration period, the model proposed by Midilli presented the best fit for all studied conditions.

  16. [Study of methods of decalcification for making united slices of tooth and affiliated periodontic tissues].

    Science.gov (United States)

    Wang, Yu; Mu, Ya-bing; Miao, Lei-ying; Sun, Hong-chen; Li, Cheng-ku

    2007-03-01

    To study the methods of decalcification for making united slices of tooth and affiliated periodontic tissues. Twenty-one samples containing dog molars and affiliated periodontic tissues were divided into seven mean groups. The pH value of solution, time of decalcification, weight and volume of samples, and content of decalcified calcium were detected. The slices were observed by HE, specific, and immunohistochemical stain. The velocity of decalcification increased with decrease of solution pH. The weight of samples lightened by 37.61%, the volume reduced by 25.97% on average, and calcium decalcified was 174.49 mg per gram humid samples. The EDTA decalcification was slowest, but it was best. Decalcification was fast in Plank-Rycho solution while the section was worst, and faster in the formyl solution containing aluminium chloride than in EDTA, and the section was better. The 50% formyl solution containing aluminium chloride is an ideal decalcifying solution.

  17. Targeting neurotransmitter receptors with nanoparticles in vivo allows single-molecule tracking in acute brain slices

    Science.gov (United States)

    Varela, Juan A.; Dupuis, Julien P.; Etchepare, Laetitia; Espana, Agnès; Cognet, Laurent; Groc, Laurent

    2016-03-01

    Single-molecule imaging has changed the way we understand many biological mechanisms, particularly in neurobiology, by shedding light on intricate molecular events down to the nanoscale. However, current single-molecule studies in neuroscience have been limited to cultured neurons or organotypic slices, leaving as an open question the existence of fast receptor diffusion in intact brain tissue. Here, for the first time, we targeted dopamine receptors in vivo with functionalized quantum dots and were able to perform single-molecule tracking in acute rat brain slices. We propose a novel delocalized and non-inflammatory way of delivering nanoparticles (NPs) in vivo to the brain, which allowed us to label and track genetically engineered surface dopamine receptors in neocortical neurons, revealing inherent behaviour and receptor activity regulations. We thus propose a NP-based platform for single-molecule studies in the living brain, opening new avenues of research in physiological and pathological animal models.

  18. Fourier-based approach to interpolation in single-slice helical computed tomography

    International Nuclear Information System (INIS)

    La Riviere, Patrick J.; Pan Xiaochuan

    2001-01-01

    It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal direction and because the exploitation of the redundancy of fanbeam data acquired over 360 degree sign to generate additional longitudinal samples does not automatically eliminate the aliasing. In this paper we demonstrate that for pitches near 1 or lower, the redundant fanbeam data, when used properly, can provide sufficient information to satisfy a generalized sampling theorem and thus to eliminate aliasing. We develop and evaluate a Fourier-based algorithm, called 180FT, that accomplishes this. As background we present a second Fourier-based approach, called 360FT, that makes use only of the directly measured data. Both Fourier-based approaches exploit the fast Fourier transform and the Fourier shift theorem to generate from the helical projection data a set of fanbeam sinograms corresponding to equispaced transverse slices. Slice-by-slice reconstruction is then performed by use of two-dimensional fanbeam algorithms. The proposed approaches are compared to their counterparts based on the use of linear interpolation - the 360LI and 180LI approaches. The aliasing suppression property of the 180FT approach is a clear advantage of the approach and represents a step toward the desirable goal of achieving uniform longitudinal resolution properties in reconstructed helical CT volumes

  19. FAST: a three-dimensional time-dependent FEL simulation code

    International Nuclear Information System (INIS)

    Saldin, E.L.; Schneidmiller, E.A.; Yurkov, M.V.

    1999-01-01

    In this report we briefly describe the three-dimensional, time-dependent FEL simulation code FAST. The equations of motion of the particles and Maxwell's equations are solved simultaneously taking into account the slippage effect. Radiation fields are calculated using an integral solution of Maxwell's equations. A special technique has been developed for fast calculations of the radiation field, drastically reducing the required CPU time. As a result, the developed code allows one to use a personal computer for time-dependent simulations. The code allows one to simulate the radiation from the electron bunch of any transverse and longitudinal bunch shape; to simulate simultaneously an external seed with superimposed noise in the electron beam; to take into account energy spread in the electron beam and the space charge fields; and to simulate a high-gain, high-efficiency FEL amplifier with a tapered undulator. It is important to note that there are no significant memory limitations in the developed code and an electron bunch of any length can be simulated

  20. Efficient on-the-fly Algorithm for Checking Alternating Timed Simulation

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Chatain, Thomas

    2009-01-01

    In this paper we focus on property-preserving preorders between timed game automata and their application to control of partially observable systems. We define timed weak alternating simulation as a preorder between timed game automata, which preserves controllability. We define the rules...... of building a symbolic turn-based two-player game such that the existence of a winning strategy is equivalent to the simulation being satisfied. We also propose an on-the-fly algorithm for solving this game. This simulation checking method can be applied to the case of non-alternating or strong simulations...

  1. Optical microwave filter based on spectral slicing by use of arrayed waveguide gratings.

    Science.gov (United States)

    Pastor, Daniel; Ortega, Beatriz; Capmany, José; Sales, Salvador; Martinez, Alfonso; Muñoz, Pascual

    2003-10-01

    We have experimentally demonstrated a new optical signal processor based on the use of arrayed waveguide gratings. The structure exploits the concept of spectral slicing combined with the use of an optical dispersive medium. The approach presents increased flexibility from previous slicing-based structures in terms of tunability, reconfiguration, and apodization of the samples or coefficients of the transversal optical filter.

  2. Multiple Time Series Ising Model for Financial Market Simulations

    International Nuclear Information System (INIS)

    Takaishi, Tetsuya

    2015-01-01

    In this paper we propose an Ising model which simulates multiple financial time series. Our model introduces the interaction which couples to spins of other systems. Simulations from our model show that time series exhibit the volatility clustering that is often observed in the real financial markets. Furthermore we also find non-zero cross correlations between the volatilities from our model. Thus our model can simulate stock markets where volatilities of stocks are mutually correlated

  3. An assessment of the number of CT slices necessary to plan breast radiotherapy

    International Nuclear Information System (INIS)

    Vincent, D.; Beckham, W.; Delaney, G.

    1999-01-01

    The aim of this study was to evaluate the number of CT slices required to produce satisfactory dose distribution for tangential field irradiation of the chest wall and breast and to assess correlation of this with the volume of breast tissue treated. We conclude that a single-slice plan is unsatisfactory in providing sufficient information about the dose variation across the treatment volume and that ideally a 3D plan with DVHs should be produced. If the required data is unavailable then a minimum of three slices should be used as an approximation. We also propose a software tool for treatment planning systems, which calculates the percentage of the total PTV having dose outside the ICRU 50 radiation dose distribution homogeneity guideline range

  4. RANA, a real-time multi-agent system simulator

    DEFF Research Database (Denmark)

    Jørgensen, Søren Vissing; Demazeau, Yves; Hallam, John

    2016-01-01

    for individualisation and abstraction while retaining efficiency. Events are managed by the C++ simulator core. Full run state can be recorded for post-processed visualisation or analysis. The new tool is demonstrated in three different cases: a mining robot simulation, which is purely action based; an agent......-based setup that is verifies the high precision exhibited by RANAs simulation core; and a state-based firefly-like agent simulation that models real-time responses to fellow agents' signals, in which event propagation and reception affect the result of the simulation....

  5. Real-Time ECG Simulation for Hybrid Mock Circulatory Loops.

    Science.gov (United States)

    Korn, Leonie; Rüschen, Daniel; Zander, Niklas; Leonhardt, Steffen; Walter, Marian

    2018-02-01

    Classically, mock circulatory loops only simulate mechanical properties of the circulation. To connect the hydraulic world with electrophysiology, we present a real-time electrical activity model of the heart and show how to integrate this model into a real-time mock loop simulation. The model incorporates a predefined conduction pathway and a simplified volume conductor to solve the bidomain equations and the forward problem of electrocardiography, resulting in a physiological simulation of the electrocardiogram (ECG) at arbitrary electrode positions. A complete physiological simulation of the heart's excitation would be too CPU intensive. Thus, in our model, complexity was reduced to allow real-time simulation of ECG-triggered medical systems in vitro; this decreases time and cost in the development process. Conversely, the presented model can still be adapted to various pathologies by locally changing the properties of the heart's conduction pathway. To simulate the ECG, the heart is divided into suitable areas, which are innervated by the hierarchically structured conduction system. To distinguish different cardiac regions, a segmentation of the heart was performed. In these regions, Prim's algorithm was applied to identify the directed minimal spanning trees for conduction orientation. Each node of the tree was assigned to a cardiac action potential generated by its hybrid automaton to represent the heart's conduction system by the spatial distribution of action potentials. To generate the ECG output, the bidomain equations were implemented and a simple model of the volume conductor of the body was used to solve the forward problem of electrocardiography. As a result, the model simulates potentials at arbitrary electrode positions in real-time. To verify the developed real-time ECG model, measurements were made within a hybrid mock circulatory loop, including a simple ECG-triggered ventricular assist device control. The model's potential value is to simulate

  6. 640-slice DVCT multi-dimensionally and dynamically presents changes in bladder volume and urine flow rate

    Science.gov (United States)

    Su, Yunshan; Fang, Kewei; Mao, Chongwen; Xiang, Shutian; Wang, Jin; Li, Yingwen

    2018-01-01

    The present study aimed to explore the application of 640-slice dynamic volume computed tomography (DVCT) to excretory cystography and urethrography. A total of 70 healthy subjects were included in the study. Excretory cystography and urethrography using 640-slice DVCT was conducted to continuously record the motions of the bladder and the proximal female and male urethra. The patients' voiding process was divided into early, early to middle, middle, middle to late, and late voiding phases. The subjects were analyzed using DVCT and conventional CT. The cross-sectional areas of various sections of the male and female urethra were evaluated, and the average urine flow rate was calculated. The 640-slice DVCT technique was used to dynamically observe the urine flow rate and changes in bladder volume at all voiding phases. The urine volume detected by 640-slice DVCT exhibited no significant difference compared with the actual volume, and no significant difference compared with that determined using conventional CT. Furthermore, no significant difference in the volume of the bladder at each phase of the voiding process was detected between 640-slice DVCT and conventional CT. The results indicate that 640-slice DVCT can accurately evaluate the status of the male posterior urethra and female urethra. In conclusion, 640-slice DVCT is able to multi-dimensionally and dynamically present changes in bladder volume and urine flow rate, and could obtain similar results to conventional CT in detecting urine volume, as well as the status of the male posterior urethra and female urethra. PMID:29467853

  7. Taxi Time Prediction at Charlotte Airport Using Fast-Time Simulation and Machine Learning Techniques

    Science.gov (United States)

    Lee, Hanbong

    2016-01-01

    Accurate taxi time prediction is required for enabling efficient runway scheduling that can increase runway throughput and reduce taxi times and fuel consumptions on the airport surface. Currently NASA and American Airlines are jointly developing a decision-support tool called Spot and Runway Departure Advisor (SARDA) that assists airport ramp controllers to make gate pushback decisions and improve the overall efficiency of airport surface traffic. In this presentation, we propose to use Linear Optimized Sequencing (LINOS), a discrete-event fast-time simulation tool, to predict taxi times and provide the estimates to the runway scheduler in real-time airport operations. To assess its prediction accuracy, we also introduce a data-driven analytical method using machine learning techniques. These two taxi time prediction methods are evaluated with actual taxi time data obtained from the SARDA human-in-the-loop (HITL) simulation for Charlotte Douglas International Airport (CLT) using various performance measurement metrics. Based on the taxi time prediction results, we also discuss how the prediction accuracy can be affected by the operational complexity at this airport and how we can improve the fast time simulation model before implementing it with an airport scheduling algorithm in a real-time environment.

  8. Tomographic apparatus and method for reconstructing planar slices from non-absorbed radiation

    International Nuclear Information System (INIS)

    1976-01-01

    In a tomographic apparatus and method for reconstructing two-dimensional planar slices from linear projections of non-absorbed radiation useful in the fields of medical radiology, microscopy, and non-destructive testing, a beam of radiation in the shape of a fan is passed through an object lying in the same quasi-plane as the object slice and non-absorbtion thereof is recorded on oppositely-situated detectors aligned with the source of radiation. There is relative rotation between the source-detector configuration and the object within the quasi-plane. Periodic values of the detected radiation are taken, convolved with certain functions, and back-projected to produce a two-dimensional output picture on a visual display illustrating a facsimile of the object slice. A series of two-dimensional pictures obtained simultaneously or serially can be combined to produce a three dimensional portrayal of the entire object

  9. Mathematical modelling of temperature effect on growth kinetics of Pseudomonas spp. on sliced mushroom (Agaricus bisporus).

    Science.gov (United States)

    Tarlak, Fatih; Ozdemir, Murat; Melikoglu, Mehmet

    2018-02-02

    The growth data of Pseudomonas spp. on sliced mushrooms (Agaricus bisporus) stored between 4 and 28°C were obtained and fitted to three different primary models, known as the modified Gompertz, logistic and Baranyi models. The goodness of fit of these models was compared by considering the mean squared error (MSE) and the coefficient of determination for nonlinear regression (pseudo-R 2 ). The Baranyi model yielded the lowest MSE and highest pseudo-R 2 values. Therefore, the Baranyi model was selected as the best primary model. Maximum specific growth rate (r max ) and lag phase duration (λ) obtained from the Baranyi model were fitted to secondary models namely, the Ratkowsky and Arrhenius models. High pseudo-R 2 and low MSE values indicated that the Arrhenius model has a high goodness of fit to determine the effect of temperature on r max . Observed number of Pseudomonas spp. on sliced mushrooms from independent experiments was compared with the predicted number of Pseudomonas spp. with the models used by considering the B f and A f values. The B f and A f values were found to be 0.974 and 1.036, respectively. The correlation between the observed and predicted number of Pseudomonas spp. was high. Mushroom spoilage was simulated as a function of temperature with the models used. The models used for Pseudomonas spp. growth can provide a fast and cost-effective alternative to traditional microbiological techniques to determine the effect of storage temperature on product shelf-life. The models can be used to evaluate the growth behaviour of Pseudomonas spp. on sliced mushroom, set limits for the quantitative detection of the microbial spoilage and assess product shelf-life. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Correlation between a 2D Channelized Hotelling Observer and Human Observers in a Low-contrast Detection Task with Multi-slice Reading in CT

    Science.gov (United States)

    Yu, Lifeng; Chen, Baiyu; Kofler, James M.; Favazza, Christopher P.; Leng, Shuai; Kupinski, Matthew A.; McCollough, Cynthia H.

    2017-01-01

    Purpose Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e. multi-slice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multi-slice reading, and to determine if the 2D model observer still correlate well with human observer performance in multi-slice reading. Methods A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at 5 dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multi-slice channelized Hotelling observer (CHO_MS), which integrates multi-slice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multi-slice viewing performance and the two CHO models. Results Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode (Pearson product-moment correlation coefficient R=0

  11. Using a high-speed movie camera to evaluate slice dropping in clinical image interpretation with stack mode viewers.

    Science.gov (United States)

    Yakami, Masahiro; Yamamoto, Akira; Yanagisawa, Morio; Sekiguchi, Hiroyuki; Kubo, Takeshi; Togashi, Kaori

    2013-06-01

    The purpose of this study is to verify objectively the rate of slice omission during paging on picture archiving and communication system (PACS) viewers by recording the images shown on the computer displays of these viewers with a high-speed movie camera. This study was approved by the institutional review board. A sequential number from 1 to 250 was superimposed on each slice of a series of clinical Digital Imaging and Communication in Medicine (DICOM) data. The slices were displayed using several DICOM viewers, including in-house developed freeware and clinical PACS viewers. The freeware viewer and one of the clinical PACS viewers included functions to prevent slice dropping. The series was displayed in stack mode and paged in both automatic and manual paging modes. The display was recorded with a high-speed movie camera and played back at a slow speed to check whether slices were dropped. The paging speeds were also measured. With a paging speed faster than half the refresh rate of the display, some viewers dropped up to 52.4 % of the slices, while other well-designed viewers did not, if used with the correct settings. Slice dropping during paging was objectively confirmed using a high-speed movie camera. To prevent slice dropping, the viewer must be specially designed for the purpose and must be used with the correct settings, or the paging speed must be slower than half of the display refresh rate.

  12. Microfilament Contraction Promotes Rounding of Tunic Slices: An Integumentary Defense System in the Colonial Ascidian Aplidium yamazii.

    Science.gov (United States)

    Hirose, E; Ishii, T

    1995-08-01

    In Aplidium yamazii, when a slice of a live colony (approximately 0.5 mm thick) was incubated in seawater for 12 h, the slice became a round tunic fragment. This tunic rounding was inhibited by freezing of the slices, incubation with Ca2+-Mg2+ -free seawater, or addition of cytochalasin B. Staining of microfilaments in the slices with phalloidin-FITC showed the existence of a cellular network in the tunic. Contraction of this cellular network probably promotes rounding of the tunic slice. In electron microscopic observations, a new tunic cuticle regenerated at the surface of the round tunic fragments; the tunic cuticle did not regenerate in newly sliced specimens nor in specimens in which rounding was experimentally inhibited. Based on these results, an integumentary defense system is proposed in this species as follows. (1) When the colony is wounded externally, contraction of the cellular network promotes tunic contraction around the wound. (2) The wound is almost closed by tunic contraction. (3) Tunic contraction increases the density of the filamentous components of the tunic at the wound, and it may accelerate the regeneration of tunic cuticle there.

  13. Time- and dose-dependent changes in neuronal activity produced by X radiation in brain slices

    International Nuclear Information System (INIS)

    Pellmar, T.C.; Schauer, D.A.; Zeman, G.H.

    1990-01-01

    A new method of exposing tissues to X rays in a lead Faraday cage has made it possible to examine directly radiation damage to isolated neuronal tissue. Thin slices of hippocampus from brains of euthanized guinea pigs were exposed to 17.4 ke V X radiation. Electrophysiological recordings were made before, during, and after exposure to doses between 5 and 65 Gy at a dose rate of 1.54 Gy/min. Following exposure to doses of 40 Gy and greater, the synaptic potential was enhanced, reaching a steady level soon after exposure. The ability of the synaptic potential to generate a spike was reduced and damage progressed after termination of the radiation exposure. Recovery was not observed following termination of exposure. These results demonstrate that an isolated neuronal network can show complex changes in electrophysiological properties following moderate doses of ionizing radiation. An investigation of radiation damage directly to neurons in vitro will contribute to the understanding of the underlying mechanisms of radiation-induced nervous system dysfunction

  14. Comparison between powder and slices diffraction methods in teeth samples

    Energy Technology Data Exchange (ETDEWEB)

    Colaco, Marcos V.; Barroso, Regina C. [Universidade do Estado do Rio de Janeiro (IF/UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada; Porto, Isabel M. [Universidade Estadual de Campinas (FOP/UNICAMP), Piracicaba, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia; Gerlach, Raquel F. [Universidade de Sao Paulo (FORP/USP), Rieirao Preto, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia, Estomatologia e Fisiologia; Costa, Fanny N. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10{sup -1}0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  15. Comparison between powder and slices diffraction methods in teeth samples

    International Nuclear Information System (INIS)

    Colaco, Marcos V.; Barroso, Regina C.; Porto, Isabel M.; Gerlach, Raquel F.; Costa, Fanny N.

    2011-01-01

    Propose different methods to obtain crystallographic information about biological materials are important since powder method is a nondestructive method. Slices are an approximation of what would be an in vivo analysis. Effects of samples preparation cause differences in scattering profiles compared with powder method. The main inorganic component of bones and teeth is a calcium phosphate mineral whose structure closely resembles hydroxyapatite (HAp). The hexagonal symmetry, however, seems to work well with the powder diffraction data, and the crystal structure of HAp is usually described in space group P63/m. Were analyzed ten third molar teeth. Five teeth were separated in enamel, detin and circumpulpal detin powder and five in slices. All the scattering profile measurements were carried out at the X-ray diffraction beamline (XRD1) at the National Synchrotron Light Laboratory - LNLS, Campinas, Brazil. The LNLS synchrotron light source is composed of a 1.37 GeV electron storage ring, delivering approximately 4x10 -1 0 photons/s at 8 keV. A double-crystal Si(111) pre-monochromator, upstream of the beamline, was used to select a small energy bandwidth at 11 keV . Scattering signatures were obtained at intervals of 0.04 deg for angles from 24 deg to 52 deg. The human enamel experimental crystallite size obtained in this work were 30(3)nm (112 reflection) and 30(3)nm (300 reflection). These values were obtained from measurements of powdered enamel. When comparing the slice obtained 58(8)nm (112 reflection) and 37(7)nm (300 reflection) enamel diffraction patterns with those generated by the powder specimens, a few differences emerge. This work shows differences between powder and slices methods, separating characteristics of sample of the method's influence. (author)

  16. Interactive real-time nuclear plant simulations on a UNIX based supercomputer

    International Nuclear Information System (INIS)

    Behling, S.R.

    1990-01-01

    Interactive real-time nuclear plant simulations are critically important to train nuclear power plant engineers and operators. In addition, real-time simulations can be used to test the validity and timing of plant technical specifications and operational procedures. To accurately and confidently simulate a nuclear power plant transient in real-time, sufficient computer resources must be available. Since some important transients cannot be simulated using preprogrammed responses or non-physical models, commonly used simulation techniques may not be adequate. However, the power of a supercomputer allows one to accurately calculate the behavior of nuclear power plants even during very complex transients. Many of these transients can be calculated in real-time or quicker on the fastest supercomputers. The concept of running interactive real-time nuclear power plant transients on a supercomputer has been tested. This paper describes the architecture of the simulation program, the techniques used to establish real-time synchronization, and other issues related to the use of supercomputers in a new and potentially very important area. (author)

  17. A Novel Slicing Method for Thin Supercapacitors.

    Science.gov (United States)

    Sun, Hao; Fu, Xuemei; Xie, Songlin; Jiang, Yishu; Guan, Guozhen; Wang, Bingjie; Li, Houpu; Peng, Huisheng

    2016-08-01

    Thin and flexible supercapacitors with low cost and individual variation are fabricated by a new and efficient slicing method. Tunable output voltage and energy can be realized with a high specific capacitance of 248.8 F g(-1) or 150.8 F cm(-3) , which is well maintained before and after bending. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Detecting Psychopathy from Thin Slices of Behavior

    Science.gov (United States)

    Fowler, Katherine A.; Lilienfeld, Scott O.; Patrick, Christopher J.

    2009-01-01

    This study is the first to demonstrate that features of psychopathy can be reliably and validly detected by lay raters from "thin slices" (i.e., small samples) of behavior. Brief excerpts (5 s, 10 s, and 20 s) from interviews with 96 maximum-security inmates were presented in video or audio form or in both modalities combined. Forty raters used…

  19. Bandwidth scalable, coherent transmitter based on the parallel synthesis of multiple spectral slices using optical arbitrary waveform generation.

    Science.gov (United States)

    Geisler, David J; Fontaine, Nicolas K; Scott, Ryan P; He, Tingting; Paraschis, Loukas; Gerstel, Ori; Heritage, Jonathan P; Yoo, S J B

    2011-04-25

    We demonstrate an optical transmitter based on dynamic optical arbitrary waveform generation (OAWG) which is capable of creating high-bandwidth (THz) data waveforms in any modulation format using the parallel synthesis of multiple coherent spectral slices. As an initial demonstration, the transmitter uses only 5.5 GHz of electrical bandwidth and two 10-GHz-wide spectral slices to create 100-ns duration, 20-GHz optical waveforms in various modulation formats including differential phase-shift keying (DPSK), quaternary phase-shift keying (QPSK), and eight phase-shift keying (8PSK) with only changes in software. The experimentally generated waveforms showed clear eye openings and separated constellation points when measured using a real-time digital coherent receiver. Bit-error-rate (BER) performance analysis resulted in a BER < 9.8 × 10(-6) for DPSK and QPSK waveforms. Additionally, we experimentally demonstrate three-slice, 4-ns long waveforms that highlight the bandwidth scalable nature of the optical transmitter. The various generated waveforms show that the key transmitter properties (i.e., packet length, modulation format, data rate, and modulation filter shape) are software definable, and that the optical transmitter is capable of acting as a flexible bandwidth transmitter.

  20. Innovative tools for real-time simulation of dynamic systems

    NARCIS (Netherlands)

    Palli, Gianluca; Carloni, Raffaella; Melchiorri, Claudio

    2008-01-01

    In this paper, we present a software architecture, based on RTAI-Linux, for the real-time simulation of dynamic systems and for the rapid prototyping of digital controllers. Our aim is to simplify the testing phase of digital controllers by providing the real-time simulation of the plant with the

  1. Issues in visual support to real-time space system simulation solved in the Systems Engineering Simulator

    Science.gov (United States)

    Yuen, Vincent K.

    1989-01-01

    The Systems Engineering Simulator has addressed the major issues in providing visual data to its real-time man-in-the-loop simulations. Out-the-window views and CCTV views are provided by three scene systems to give the astronauts their real-world views. To expand the window coverage for the Space Station Freedom workstation a rotating optics system is used to provide the widest field of view possible. To provide video signals to as many viewpoints as possible, windows and CCTVs, with a limited amount of hardware, a video distribution system has been developed to time-share the video channels among viewpoints at the selection of the simulation users. These solutions have provided the visual simulation facility for real-time man-in-the-loop simulations for the NASA space program.

  2. Slice of a LEP bending magnet

    CERN Multimedia

    This is a slice of a LEP dipole bending magnet, made as a concrete and iron sandwich. The bending field needed in LEP is small (about 1000 Gauss), equivalent to two of the magnets people stick on fridge doors. Because it is very difficult to keep a low field steady, a high field was used in iron plates embedded in concrete. A CERN breakthrough in magnet design, LEP dipoles can be tuned easily and are cheaper than conventional magnets.

  3. Isoproterenol effects evaluated in heart slices of human and rat in comparison to rat heart in vivo

    International Nuclear Information System (INIS)

    Herrmann, Julia E.; Heale, Jason; Bieraugel, Mike; Ramos, Meg; Fisher, Robyn L.; Vickers, Alison E.M.

    2014-01-01

    Human response to isoproterenol induced cardiac injury was evaluated by gene and protein pathway changes in human heart slices, and compared to rat heart slices and rat heart in vivo. Isoproterenol (10 and 100 μM) altered human and rat heart slice markers of oxidative stress (ATP and GSH) at 24 h. In this in vivo rat study (0.5 mg/kg), serum troponin concentrations increased with lesion severity, minimal to mild necrosis at 24 and 48 h. In the rat and the human heart, isoproterenol altered pathways for apoptosis/necrosis, stress/energy, inflammation, and remodeling/fibrosis. The rat and human heart slices were in an apoptotic phase, while the in vivo rat heart exhibited necrosis histologically and further progression of tissue remodeling. In human heart slices genes for several heat shock 70 kD members were altered, indicative of stress to mitigate apoptosis. The stress response included alterations in energy utilization, fatty acid processing, and the up-regulation of inducible nitric oxide synthase, a marker of increased oxidative stress in both species. Inflammation markers linked with remodeling included IL-1α, Il-1β, IL-6 and TNFα in both species. Tissue remodeling changes in both species included increases in the TIMP proteins, inhibitors of matrix degradation, the gene/protein of IL-4 linked with cardiac fibrosis, and the gene Ccl7 a chemokine that induces collagen synthesis, and Reg3b a growth factor for cardiac repair. This study demonstrates that the initial human heart slice response to isoproterenol cardiac injury results in apoptosis, stress/energy status, inflammation and tissue remodeling at concentrations similar to that in rat heart slices. - Highlights: • Human response to isoproterenol induced cardiac injury evaluated in heart slices. • Isoproterenol altered apoptosis, energy, inflammation and remodeling pathways. • Human model verified by comparison to rat heart slices and rat heart in vivo. • Human and rat respond to isoproterenol

  4. Real-time model for simulating a tracked vehicle on deformable soils

    Directory of Open Access Journals (Sweden)

    Martin Meywerk

    2016-05-01

    Full Text Available Simulation is one possibility to gain insight into the behaviour of tracked vehicles on deformable soils. A lot of publications are known on this topic, but most of the simulations described there cannot be run in real-time. The ability to run a simulation in real-time is necessary for driving simulators. This article describes an approach for real-time simulation of a tracked vehicle on deformable soils. The components of the real-time model are as follows: a conventional wheeled vehicle simulated in the Multi Body System software TRUCKSim, a geometric description of landscape, a track model and an interaction model between track and deformable soils based on Bekker theory and Janosi–Hanamoto, on one hand, and between track and vehicle wheels, on the other hand. Landscape, track model, soil model and the interaction are implemented in MATLAB/Simulink. The details of the real-time model are described in this article, and a detailed description of the Multi Body System part is omitted. Simulations with the real-time model are compared to measurements and to a detailed Multi Body System–finite element method model of a tracked vehicle. An application of the real-time model in a driving simulator is presented, in which 13 drivers assess the comfort of a passive and an active suspension of a tracked vehicle.

  5. Evaluation of the possibility to use thick slabs of reconstructed outer breast tomosynthesis slice images

    Science.gov (United States)

    Petersson, Hannie; Dustler, Magnus; Tingberg, Anders; Timberg, Pontus

    2016-03-01

    The large image volumes in breast tomosynthesis (BT) have led to large amounts of data and a heavy workload for breast radiologists. The number of slice images can be decreased by combining adjacent image planes (slabbing) but the decrease in depth resolution can considerably affect the detection of lesions. The aim of this work was to assess if thicker slabbing of the outer slice images (where lesions seldom are present) could be a viable alternative in order to reduce the number of slice images in BT image volumes. The suggested slabbing (an image volume with thick outer slabs and thin slices between) were evaluated in two steps. Firstly, a survey of the depth of 65 cancer lesions within the breast was performed to estimate how many lesions would be affected by outer slabs of different thicknesses. Secondly, a selection of 24 lesions was reconstructed with 2, 6 and 10 mm slab thickness to evaluate how the appearance of lesions located in the thicker slabs would be affected. The results show that few malignant breast lesions are located at a depth less than 10 mm from the surface (especially for breast thicknesses of 50 mm and above). Reconstruction of BT volumes with 6 mm slab thickness yields an image quality that is sufficient for lesion detection for a majority of the investigated cases. Together, this indicates that thicker slabbing of the outer slice images is a promising option in order to reduce the number of slice images in BT image volumes.

  6. Influence of detector collimation on SNR in four different MDCT scanners using a reconstructed slice thickness of 5 mm

    International Nuclear Information System (INIS)

    Verdun, F.R.; Pachoud, M.; Monnin, P.; Valley, J.-F.; Noel, A.; Meuli, R.; Schnyder, P.; Denys, A.

    2004-01-01

    The purpose of this paper is to compare the influence of detector collimation on the signal-to-noise ratio (SNR) for a 5.0 mm reconstructed slice thickness for four multi-detector row CT (MDCT) units. SNRs were measured on Catphan test phantom images from four MDCT units: a GE LightSpeed QX/I, a Marconi MX 8000, a Toshiba Aquilion and a Siemens Volume Zoom. Five-millimetre-thick reconstructed slices were obtained from acquisitions performed using detector collimations of 2.0-2.5 mm and 5.0 mm, 120 kV, a 360 tube rotation time of 0.5 s, a wide range of mA and pitch values in the range of 0.75-0.85 and 1.25-1.5. For each set of acquisition parameters, a Wiener spectrum was also calculated. Statistical differences in SNR for the different acquisition parameters were evaluated using a Student's t-test (P<0.05). The influence of detector collimation on the SNR for a 5.0-mm reconstructed slice thickness is different for different MDCT scanners. At pitch values lower than unity, the use of a small detector collimation to produce 5.0-mm thick slices is beneficial for one unit and detrimental for another. At pitch values higher than unity, using a small detector collimation is beneficial for two units. One manufacturer uses different reconstruction filters when switching from a 2.5- to a 5.0-mm detector collimation. For a comparable reconstructed slice thickness, using a smaller detector collimation does not always reduce image noise. Thus, the impact of the detector collimation on image noise should be determined by standard deviation calculations, and also by assessing the power spectra of the noise. (orig.)

  7. Slicing Cuts on Food Materials Using Robotic-Controlled Razor Blade

    Directory of Open Access Journals (Sweden)

    Debao Zhou

    2011-01-01

    Full Text Available Cutting operations using blades can arise in a number of industries, for example, food processing industry, in which cheese, fruit and vegetable, even meat, are involved. Certain questions will rise during these works, such as “why pressing-and-slicing cuts use less force than pressing-only cuts” and “how is the influence of the blade cutting-edge on force”. To answer these questions, this research developed a mathematical expression of the cutting stress tensor. Based on the analysis of the stress tensor on the contact surface, the influence of the blade edge-shape and slicing angle on the resultant cutting force were formulated and discussed. These formulations were further verified using experimental results by robotic cutting of potatoes. Through studying the change of the cutting force, the optimal slicing angle can be obtained in terms of maximum feeding distance and minimum cutting force. Based on the blade sharpness properties and the specific materials, the required cutting force can be predicted. These formulation and experimental results explained the basic theory of blade cutting fracture and further provided the support to optimize the cutting mechanism design and to develop the force control algorithms for the automation of blade cutting operations.

  8. Actinic keratosis in the en-face and slice imaging mode of high-definition optical coherence tomography and comparison with histology.

    Science.gov (United States)

    Maier, T; Braun-Falco, M; Laubender, R P; Ruzicka, T; Berking, C

    2013-01-01

    Optical coherence tomography (OCT) allows real-time, in vivo examination of nonmelanoma skin cancer. An innovative high-definition (HD)-OCT with a horizontal (en-face) and vertical (slice) imaging mode offers additional information in the diagnosis of actinic keratosis (AK) and may potentially replace invasive diagnostic biopsies.  To define the characteristic morphological features of AK by using HD-OCT in the two imaging modes compared with histopathology as gold standard.  In total, 20 AKs were examined by HD-OCT in the en-face and slice imaging modes and characteristic features were described and evaluated in comparison with the histopathological findings. Furthermore, the HD-OCT images of a subgroup of AKs were compared with those of the clinically normal adjacent skin.  The preoperative in vivo diagnostics showed the following features in the en-face imaging mode of HD-OCT: disruption of stratum corneum, architectural disarray, cellular/nuclear polymorphism in the stratum granulosum/stratum spinosum, and bright irregular bundles in the superficial dermis. In the vertical slice imaging mode the following characteristics were found: irregular entrance signal, destruction of layering, white streaks and dots, and grey areas. In contrast, the clinically healthy adjacent skin showed mainly a regular epidermal 'honeycomb' pattern in the en-face mode and distinct layering of the skin in the slice mode.  HD-OCT with both the en-face and slice imaging modes offers additional information in the diagnosis of AK compared with conventional OCT and might enhance the possibility of the noninvasive diagnosis of AK prior to treatment procedures and possibly in the monitoring of noninvasive treatment strategies. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.

  9. Effects of intratracheal instillation of bleomycin on phospholipid synthesis in hamster lung tissue slices

    International Nuclear Information System (INIS)

    Giri, S.N.

    1987-01-01

    Bleomycin, an antineoplastic drug, is known to produce interstitial pulmonary fibrosis (IPF). As a result, it is commonly employed in various species to produce animal models of fibrosis. We have examined the uptake of [ 14 C] acetate by lung slices and its incorporation into lipids in the slices at various times following intratracheal administration of a fibrogenic dose of bleomycin in hamsters. As compared to saline controls, bleomycin had no effect on [ 14 C] acetate uptake at 4 and 7 days but it increased the uptake at 2 and 14 days after treatment. The incorporation of [ 14 C] acetate into total lipid was significantly reduced to 44, 62, 62, and 75% of the control at 2, 4, 7, and 14 days after bleomycin treatment, respectively. The incorporation into lipid as a percentage of the uptake was 12.2 in control animals whereas in bleomycin-treated animals, it was 4.7, 8.0, 7.3, and 6.9 at the corresponding times. Separation of lipids into various fractions revealed that bleomycin treatment specifically inhibited the synthesis of phosphatidylcholine and neutral lipid at all times of the study. The synthesis of all other phospholipids except phosphatidylethanolamine was depressed at 2 days. The latter was, however, depressed at 7 and 14 days after bleomycin treatment. It was concluded from the present study that bleomycin treatment inhibits the synthesis of phospholipid and neutral lipid and this may eventually lead to decreased surfactant production

  10. Plastome-wide comparison reveals new SNV resources for the authentication of Dendrobium huoshanense and its corresponding medicinal slice (Huoshan Fengdou).

    Science.gov (United States)

    Niu, Zhitao; Pan, Jiajia; Xue, Qingyun; Zhu, Shuying; Liu, Wei; Ding, Xiaoyu

    2018-05-01

    Dendrobium species and their corresponding medicinal slices have been extensively used as traditional Chinese medicine (TCM) in many Asian countries. However, it is extremely difficult to identify Dendrobium species based on their morphological and chemical features. In this study, the plastomes of D. huoshanense were used as a model system to investigate the hypothesis that plastomic mutational hotspot regions could provide a useful single nucleotide variants (SNVs) resource for authentication studies. We surveyed the plastomes of 17 Dendrobium species, including the newly sequenced plastome of D. huoshanense . A total of 19 SNVs that could be used for the authentication of D. huoshanense were detected. On the basis of this comprehensive comparison, we identified the four most informative hotspot regions in the Dendrobium plastome that encompass ccsA to ndhF , matK to 3'trnG , rpoB to psbD, and trnT to rbcL . Furthermore, to established a simple and accurate method for the authentication of D. huoshanense and its medicinal slices, a total of 127 samples from 20 Dendrobium species including their corresponding medicinal slices (Fengdous) were used in this study. Our results suggest that D. huoshanense and its medicinal slices can be rapidly and unequivocally identified using this method that combines real-time PCR with the amplification refractory mutation system (ARMS).

  11. Evaluation of the relative biological effectiveness of carbon ion beams in the cerebellum using the rat organotypic slice culture system

    International Nuclear Information System (INIS)

    Yoshida, Yukari; Katoh, Hiroyuki; Nakano, Takashi; Suzuki, Yoshiyuki; Al-Jahdari, Wael S.; Shirai, Katsuyuki; Hamada, Nobuyuki; Funayama, Tomoo; Sakashita, Tetsuya; Kobayashi, Yasuhiko

    2012-01-01

    The purpose of this study was to clarify the relative biological effectiveness (RBE) values of carbon ion (C) beams in normal brain tissues, a rat organotypic slice culture system was used. The cerebellum was dissected from 10-day-old Wistar rats, cut parasagittally into approximately 600-μm-thick slices and cultivated using a membrane-based culture system with a liquid-air interface. Slices were irradiated with 140 kV X-rays and 18.3 MeV/amu C-beams (linear energy transfer=108 keV/μm). After irradiation, the slices were evaluated histopathologically using hematoxylin and eosin staining, and apoptosis was quantified using the TdT-mediated dUTP-biotin nick-end labeling (TUNEL) assay. Disorganization of the external granule cell layer (EGL) and apoptosis of the external granule cells (EGCs) were induced within 24 h after exposure to doses of more than 5 Gy from C-beams and X-rays. In the early postnatal cerebellum, morphological changes following exposure to C-beams were similar to those following exposure to X-rays. The RBEs values of C-beams using the EGL disorganization and the EGC TUNEL index endpoints ranged from 1.4 to 1.5. This system represents a useful model for assaying the biological effects of radiation on the brain, especially physiological and time-dependent phenomena. (author)

  12. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    International Nuclear Information System (INIS)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem; Plass, Andre; Gaemperli, Oliver; Kaufmann, Philipp A.

    2007-01-01

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  13. Effects of metal ions on agonist-stimulated accumulation of inositol phosphates in hippocampal and cortical slices

    International Nuclear Information System (INIS)

    Bonner, M.J.; Tilson, H.A.

    1990-01-01

    [ 3 H]-inositol was incorporated into rat hippocampal or cortical slices. Zinc chloride and three different forms of inorganic lead compounds, lead chloride, lead nitrate, and lead acetate were used to stimulate PI metabolism at concentrations between 10 -15 and 10 -9 M. At these concentrations, these metal ions did not produce any significant stimulation of IP release. In birth hippocampal and cortical slices, carbachol produced equal levels of IP release. Norepinephrine (NE) produced a 10-15% higher stimulation than carbachol. When the metal ions were added to hippocampal slices together with the agonists, there was a general suppression of carbachol- or NE-induced IP release. This general suppression was not observed in cortical slices. These data suggest that the trace metals used inhibit agonist-induced second messenger release in the hippocampus

  14. Microbial growth and sensory quality of dried potato slices irradiated by electrons

    International Nuclear Information System (INIS)

    Kim, Hyun-Jin; Song, Hyeon-Jeong; Song, Kyung-Bin

    2011-01-01

    Electron beam irradiation was applied to secure the microbial safety of dried purple sweet potato. After purple sweet potato slices had been dehydrated with 20% (w/w) maltodextrin solution, the samples were irradiated at doses 2, 4, 6, 8, and 10 kGy and then stored at 20 o C for 60 days. Microbiological data indicated that the populations of total aerobic bacteria and of yeast and molds significantly decreased with increase in irradiation dosage. Specifically, microbial load was reduced by about three log cycles at 6 kGy compared to those of the control. Based on the color measurement of the potato slices, electron beam irradiation treatment did not affect the color quality. Sensory evaluation results also showed that electron beam irradiation did not affect overall sensory scores during storage. These results suggest that electron beam irradiation could be useful for improving microbial safety without impairing the quality of the potato slices during storage.

  15. Time-dependent simulation of organic light-emitting diodes

    International Nuclear Information System (INIS)

    Sharifi, M J

    2009-01-01

    Several methods to simulate the behavior of organic light-emitting diodes (OLEDs) have been proposed in the past. In this paper, we develop a previous method, based on the master equation, in order to allow the simulation of time-dependent behavior and transient states. The calculation algorithm of the program that we have written is described. The time-dependent behaviors of two simple monolayer devices and of a more complicated three-layer device were simulated by means of this program, and the results are discussed. The results show that the turn-off speed of an OLED might be very slow, especially in the case of a multilayer device. This behavior is related to the low mobility of the organic material in weak electric fields. An interesting feature of the time behavior is pointed out, whereby the recombination rate may become considerably larger after the falling edge of an applied voltage pulse. Moreover, the validity of the transient electro-luminescent method for measuring carrier mobility in organic material has been examined by means of simulation. The results show that there is some inconsistency especially in high electric fields

  16. Turnover and release of GABA in rat cortical slices: effect of a GABA-T inhibitor, gabaculine

    International Nuclear Information System (INIS)

    Szerb, J.C.

    1982-01-01

    The turnover and release of endogenous and labeled GABA were followed in rat cortical slices after incubation with [ 3 H]GABA. High performance liquid chromatography was used to measure endogenous GABA and to separate [ 3 H]GABA from its metabolites. During superfusion with 3 mM K + the slices rapidly lost their [ 3 H]GABA content while maintaining constant GABA levels. Exposure to 50 mM K + for 25 min caused an initial rapid rise in the release of both endogenous and [ 3 H]GABA followed by a more rapid decline in the release of the latter. The specific activity of released GABA was two to four times higher than that in the slices. Depolarization lead to a net synthesis of GABA. The GABA -T inhibitor, gabaculine, (5 micrometers) in vitro arrested the metabolism of [ 3 H]GABA and rapidly doubled the GABA content but did not significantly increase the high K + evoked release of endogenous GABA. In vivo pretreatment with 0.5 mM/kg gabaculine quadrupled GABA content and increased both the spontaneous and evoked release of endogenous GABA but while its Ca 2 + -dependent release increased by 50%, the Ca 2 + -independent release was enhanced sevenfold. This large Ca 2 + -independent release of GABA is likely to have different functional significance from the normal Ca 2 + -dependent release

  17. Exposure (mAs) optimisation of a multi-detector CT protocol for hepatic lesion detection: are thinner slices better?

    International Nuclear Information System (INIS)

    Dobeli, Karen L.; Lewis, Sarah J.; Meikle, Steven R.; Brennan, Patrick C.; Thiele, David L.

    2014-01-01

    The purpose of this work was to determine the exposure-optimised slice thickness for hepatic lesion detection with CT. A phantom containing spheres (diameter 9.5, 4.8 and 2.4mm) with CT density 10 HU below the background (50 HU) was scanned at 125, 100, 75 and 50 mAs. Data were reconstructed at 5-, 3- and 1-mm slice thicknesses. Noise, contrast-to-noise ratio (CNR), area under the curve (AUC) as calculated using receiver operating characteristic analysis and sensitivity representing lesion detection were calculated and compared. Compared with the 125 mAs/5mm slice thickness setting, significant reductions in AUC were found for 75 mAs (P<0.01) and 50 mAs (P<0.05) at 1- and 3-mm thicknesses, respectively; sensitivity for the 9.5-mm sphere was significantly reduced for 75 (P<0.05) and 50 mAs (P<0.01) at 1-mm thickness; sensitivity for the 4.8-mm sphere was significantly lower for 100, 75 and 50 mAs at all three slice thicknesses (P<0.05). The 2.4-mm sphere was rarely detected. At each slice thickness, noise at 100, 75 and 50 mAs exposures was approximately 10, 30 and 50% higher, respectively, than that at 125 mAs exposure. CNRs decreased in an irregular manner with reductions in exposure and slice thickness. This study demonstrated no advantage to using slices below 5mm thickness, and consequently thinner slices are not necessarily better.

  18. Real time simulation method for fast breeder reactors dynamics

    International Nuclear Information System (INIS)

    Miki, Tetsushi; Mineo, Yoshiyuki; Ogino, Takamichi; Kishida, Koji; Furuichi, Kenji.

    1985-01-01

    The development of multi-purpose real time simulator models with suitable plant dynamics was made; these models can be used not only in training operators but also in designing control systems, operation sequences and many other items which must be studied for the development of new type reactors. The prototype fast breeder reactor ''Monju'' is taken as an example. Analysis is made on various factors affecting the accuracy and computer load of its dynamic simulation. A method is presented which determines the optimum number of nodes in distributed systems and time steps. The oscillations due to the numerical instability are observed in the dynamic simulation of evaporators with a small number of nodes, and a method to cancel these oscillations is proposed. It has been verified through the development of plant dynamics simulation codes that these methods can provide efficient real time dynamics models of fast breeder reactors. (author)

  19. The bit slice micro-processor 'GESPRO' as a project in the UA2 experiment

    International Nuclear Information System (INIS)

    Becam, C.; Bernaudin, P.; Delanghe, J.; Mencik, M.; Merkel, B.; Plothow, H.; Fest, H.M.; Lecoq, J.; Martin, H.; Meyer, J.M.

    1981-01-01

    The bit slice micro-processor GESPRO, as it is proposed for use in the UA 2 data acquisition chain and trigger system, is a CAMAC module plugged into a standard Elliott System crate via which it communicates as a slave with its host computer (ND, DEC). It has full control of CAMAC as a master unit. GESPRO is a 24 bit machine (150 ns effective cycle time) with multi-mode memory addressing capacity of 64 K words. The micro-processor structure uses 5 busses including pipe-line registers to mask access time and 16 interrupt levels. The micro-program memory capacity is 2 K (RAM) words of 48 bits each. A special hardwired module allows floating point (as well as integer) multiplication of 24 x 24 bits, result in 48 bits, in about 200 ns. This micro-processor could be used in the UA2 data acquisition chain and trigger system for the following tasks: a) online data reduction, i.e. to read DURANDAL (fast ADC's = the hardware trigger in the experiment), process the information (effective mass calculation, etc.) resulting in accepting or rejecting the event. b) read out and analysis of the accepted data (collect statistical information). c) preprocess the data (calculation of pointers, address decoding, etc.). The UA2 version of GESPRO is under construction, programs and micro-programs are under development. Hardware and software will be tested with simulated data. First results are expected in about one year from now. (orig.)

  20. Application of 2 mm thin-slice scanning with bone algorithm on conventional CT in diagnosis of the pulmonary diseases

    International Nuclear Information System (INIS)

    Zhang Xianheng; Li Xiuhua; Wang Fenghua

    2004-01-01

    Objective: To evaluate the value of 2 mm thin-slice conventional CT scan with bone algorithm in diagnosis and differential diagnosis in the pulmonary diseases. Methods: In total 135 cases of the pulmonary diseases were routinely scanned by conventional scan, 10 mm per slice, with standard algorithm, then the 2 mm thin-slice scan with bone algorithm was performed at the interested region of the lungs. Result: According to the comparative study of the CT signs between 10 mm slice scan with standard algorithm and 2 mm thin-slice scan with bone algorithm, the latter was better on displaying the pulmonary axial interstium, intralobular septum, subpleura lines, honeycombing, 2-5 mm nodulars and anomalies of bronchial wall. Conclusion: According to the study of 135 cases, 2 mm thin-slice scan with bone algorithm is superior to 10 mm slice scan with standard algorithm in demonstrating the pulmonary lesions. It has a similar value with high-resolution spiral CT in the diagnosis of the pulmonary solitary or diffuse nodules, pulmonary diffuse interstitial lesions and the lesions of the airway. It is practical and advisable in the community hospital

  1. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    htmlabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  2. A slicing-based approach for locating type errors

    NARCIS (Netherlands)

    T.B. Dinesh; F. Tip (Frank)

    1998-01-01

    textabstractThe effectiveness of a type checking tool strongly depends on the accuracy of the positional information that is associated with type errors. We present an approach where the location associated with an error message e is defined as a slice P_e of the program P being type checked. We

  3. Colour behaviour on mango ( Mangifera indica ) slices self ...

    African Journals Online (AJOL)

    The effect of the syrup composition on behaviour colour of self stabilized mango slices in glass jars by hurdle technology during 180 days of storage was studied through 26-2 fractional factorial design. L* (lightness), a* (redness and greenness), and b* (yellowness and blueness) values were measured with a colorimeter ...

  4. Parametric Room Acoustic workflows with real-time acoustic simulation

    DEFF Research Database (Denmark)

    Parigi, Dario

    2017-01-01

    The paper investigates and assesses the opportunities that real-time acoustic simulation offer to engage in parametric acoustics workflow and to influence architectural designs from early design stages......The paper investigates and assesses the opportunities that real-time acoustic simulation offer to engage in parametric acoustics workflow and to influence architectural designs from early design stages...

  5. Subject-specific computer simulation model for determining elbow loading in one-handed tennis backhand groundstrokes.

    Science.gov (United States)

    King, Mark A; Glynn, Jonathan A; Mitchell, Sean R

    2011-11-01

    A subject-specific angle-driven computer model of a tennis player, combined with a forward dynamics, equipment-specific computer model of tennis ball-racket impacts, was developed to determine the effect of ball-racket impacts on loading at the elbow for one-handed backhand groundstrokes. Matching subject-specific computer simulations of a typical topspin/slice one-handed backhand groundstroke performed by an elite tennis player were done with root mean square differences between performance and matching simulations of elbow loading for a topspin and slice one-handed backhand groundstroke is relatively small. In this study, the relatively small differences in elbow loading may be due to comparable angle-time histories at the wrist and elbow joints with the major kinematic differences occurring at the shoulder. Using a subject-specific angle-driven computer model combined with a forward dynamics, equipment-specific computer model of tennis ball-racket impacts allows peak internal loading, net impulse, and shock due to ball-racket impact to be calculated which would not otherwise be possible without impractical invasive techniques. This study provides a basis for further investigation of the factors that may increase elbow loading during tennis strokes.

  6. Regulation of dopamine synthesis and release in striatal and prefrontal cortical brain slices

    International Nuclear Information System (INIS)

    Wolf, M.E.

    1986-01-01

    Brain slices were used to investigate the role of nerve terminal autoreceptors in modulating dopamine (DA) synthesis and release in striatum and prefrontal cortex. Accumulation of dihydroxyphenylalanine (DOPA) was used as an index of tyrosine hydroxylation in vitro. Nomifensine, a DA uptake blocker, inhibited DOPA synthesis in striatal but not prefrontal slices. This effect was reversed by the DA antagonist sulpiride, suggesting it involved activation of DA receptors by elevated synaptic levels of DA. The autoreceptor-selective agonist EMD-23-448 also inhibited striatal but not prefrontal DOPA synthesis. DOPA synthesis was stimulated in both brain regions by elevated K + , however only striatal synthesis could be further enhanced by sulpiride. DA release was measured by following the efflux of radioactivity from brain slices prelabeled with [ 3 H]-DA. EMD-23-448 and apomorphine inhibited, while sulpiride enhanced, the K + -evoked overflow of radioactivity from both striatal and prefrontal cortical slices. These findings suggest that striatal DA nerve terminals possess autoreceptors which modulate tyrosine hydroxylation as well as autoreceptors which modulate release. Alternatively, one site may be coupled to both functions through distinct transduction mechanisms. In contrast, autoreceptors on prefrontal cortical terminals appear to regulate DA release but not DA synthesis

  7. The energy demand of fast neuronal network oscillations: insights from brain slice preparations

    Directory of Open Access Journals (Sweden)

    Oliver eKann

    2012-01-01

    Full Text Available Fast neuronal network oscillations in the gamma range (30-100 Hz in the cerebral cortex have been implicated in higher cognitive functions such as sensual perception, working memory, and, perhaps, consciousness. However, little is known about the energy demand of gamma oscillations. This is mainly caused by technical limitations that are associated with simultaneous recordings of neuronal activity and energy metabolism in small neuronal networks and at the level of mitochondria in vivo. Thus recent studies have focused on brain slice preparations to address the energy demand of gamma oscillations in vitro. Here, reports will be summarized and discussed that combined electrophysiological recordings, oxygen sensor microelectrodes and live-cell fluorescence imaging in acutely prepared slices and organotypic slice cultures of the hippocampus from both, mouse and rat. These reports consistently show that gamma oscillations can be reliably induced in hippocampal slice preparations by different pharmacological tools. They suggest that gamma oscillations are associated with high energy demand, requiring both rapid adaptation of oxidative energy metabolism and sufficient supply with oxygen and nutrients. These findings might help to explain the exceptional vulnerability of higher cognitive functions during pathological processes of the brain, such as circulatory disturbances, genetic mitochondrial diseases, and neurodegeneration.

  8. The Slice Algorithm For Irreducible Decomposition of Monomial Ideals

    DEFF Research Database (Denmark)

    Roune, Bjarke Hammersholt

    2009-01-01

    Irreducible decomposition of monomial ideals has an increasing number of applications from biology to pure math. This paper presents the Slice Algorithm for computing irreducible decompositions, Alexander duals and socles of monomial ideals. The paper includes experiments showing good performance...

  9. An axisymmetric evolution code for the Einstein equations on hyperboloidal slices

    International Nuclear Information System (INIS)

    Rinne, Oliver

    2010-01-01

    We present the first stable dynamical numerical evolutions of the Einstein equations in terms of a conformally rescaled metric on hyperboloidal hypersurfaces extending to future null infinity. Axisymmetry is imposed in order to reduce the computational cost. The formulation is based on an earlier axisymmetric evolution scheme, adapted to time slices of constant mean curvature. Ideas from a previous study by Moncrief and the author are applied in order to regularize the formally singular evolution equations at future null infinity. Long-term stable and convergent evolutions of Schwarzschild spacetime are obtained, including a gravitational perturbation. The Bondi news function is evaluated at future null infinity.

  10. The Space-Time Conservative Schemes for Large-Scale, Time-Accurate Flow Simulations with Tetrahedral Meshes

    Science.gov (United States)

    Venkatachari, Balaji Shankar; Streett, Craig L.; Chang, Chau-Lyan; Friedlander, David J.; Wang, Xiao-Yen; Chang, Sin-Chung

    2016-01-01

    Despite decades of development of unstructured mesh methods, high-fidelity time-accurate simulations are still predominantly carried out on structured, or unstructured hexahedral meshes by using high-order finite-difference, weighted essentially non-oscillatory (WENO), or hybrid schemes formed by their combinations. In this work, the space-time conservation element solution element (CESE) method is used to simulate several flow problems including supersonic jet/shock interaction and its impact on launch vehicle acoustics, and direct numerical simulations of turbulent flows using tetrahedral meshes. This paper provides a status report for the continuing development of the space-time conservation element solution element (CESE) numerical and software framework under the Revolutionary Computational Aerosciences (RCA) project. Solution accuracy and large-scale parallel performance of the numerical framework is assessed with the goal of providing a viable paradigm for future high-fidelity flow physics simulations.

  11. Comparison of MRI fast SPGR single slice scan and continuous dynamic scan in patients with obstructive sleep apnea-hypopnea syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xinyu [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: myginny2@sina.com; Yang Xue [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: yangxueqyfy@126.com; Hua Hui [Department of Otorhinolaryngology-Head and Neck Surgery, Medical School Hospital of Qingdao University, Qingdao (China)], E-mail: huahuisky@163.com; Chen Jingjing [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: chenjingjingsky@126.com

    2009-07-15

    Objective: To evaluate the application value of MRI fast SPGR single slice scan in patients with obstructive sleep apnea-hypopnea syndrome when comparing the images between fast SPGR single slice scan and continuous dynamic scan. Methods: Eighteen patients with obstructive sleep apnea-hypopnea syndrome were examined by fast SPGR single slice scan and continuous dynamic scan in turn. Fast SPGR single slice scans were conducted when the phases of apnea, inspiration and expiration appeared on the respiratory wave of the subjects. Fast SPGR continuous dynamic scans were conducted when the patients were awake and apneic. The scan planes were median sagittal plane and axial planes (the slice of middle part of palate, the slice of inferior part of palate, the slice of middle part of lingual root and the slice of 0.5 cm beneath the free margin of epiglottis). The obstructed sites and the cross-sectional areas of upper airway were compared between the two scan methods. Results: Seven cases showed complete obstruction at the narrowest sites of upper airway when apnea appeared; eleven cases showed marked decrease in cross-sectional areas at the narrowest sites compared with the areas when the patients were awake; two cases manifested multiple narrowness. The obstructed sites showed by the two scan methods were same. The difference of the cross-sectional areas of upper airway between the two scan methods was insignificant (P > 0.05). Conclusion: Fast SPGR single slice scan can accurately reflect the obstructed sites of upper airway when the breath breaks off and is the complementary method of continuous dynamic scan. Sometimes, single slice scan can replace continuous dynamic scan.

  12. Three-dimensional electrode array for brain slice culture

    DEFF Research Database (Denmark)

    Vazquez Rodriguez, Patricia

    Multielektroder arrays (MEA) er rækker af elektroder mest i mikrometer størrelse, som er blevet brugt i stor omfang til at stimulere og måle elektrisk aktivitet fra neuronale netværker. Brug af disse for at analysere hjerne slices (hjerneskiver) kan give indsigt i interaktioner mellem neuroner, e...

  13. Use of high performance networks and supercomputers for real-time flight simulation

    Science.gov (United States)

    Cleveland, Jeff I., II

    1993-01-01

    In order to meet the stringent time-critical requirements for real-time man-in-the-loop flight simulation, computer processing operations must be consistent in processing time and be completed in as short a time as possible. These operations include simulation mathematical model computation and data input/output to the simulators. In 1986, in response to increased demands for flight simulation performance, NASA's Langley Research Center (LaRC), working with the contractor, developed extensions to the Computer Automated Measurement and Control (CAMAC) technology which resulted in a factor of ten increase in the effective bandwidth and reduced latency of modules necessary for simulator communication. This technology extension is being used by more than 80 leading technological developers in the United States, Canada, and Europe. Included among the commercial applications are nuclear process control, power grid analysis, process monitoring, real-time simulation, and radar data acquisition. Personnel at LaRC are completing the development of the use of supercomputers for mathematical model computation to support real-time flight simulation. This includes the development of a real-time operating system and development of specialized software and hardware for the simulator network. This paper describes the data acquisition technology and the development of supercomputing for flight simulation.

  14. Precision-cut kidney slices (PCKS to study development of renal fibrosis and efficacy of drug targeting ex vivo

    Directory of Open Access Journals (Sweden)

    Fariba Poosti

    2015-10-01

    Full Text Available Renal fibrosis is a serious clinical problem resulting in the greatest need for renal replacement therapy. No adequate preventive or curative therapy is available that could be clinically used to target renal fibrosis specifically. The search for new efficacious treatment strategies is therefore warranted. Although in vitro models using homogeneous cell populations have contributed to the understanding of the pathogenetic mechanisms involved in renal fibrosis, these models poorly mimic the complex in vivo milieu. Therefore, we here evaluated a precision-cut kidney slice (PCKS model as a new, multicellular ex vivo model to study the development of fibrosis and its prevention using anti-fibrotic compounds. Precision-cut slices (200-300 μm thickness were prepared from healthy C57BL/6 mouse kidneys using a Krumdieck tissue slicer. To induce changes mimicking the fibrotic process, slices were incubated with TGFβ1 (5 ng/ml for 48 h in the presence or absence of the anti-fibrotic cytokine IFNγ (1 µg/ml or an IFNγ conjugate targeted to PDGFRβ (PPB-PEG-IFNγ. Following culture, tissue viability (ATP-content and expression of α-SMA, fibronectin, collagen I and collagen III were determined using real-time PCR and immunohistochemistry. Slices remained viable up to 72 h of incubation, and no significant effects of TGFβ1 and IFNγ on viability were observed. TGFβ1 markedly increased α-SMA, fibronectin and collagen I mRNA and protein expression levels. IFNγ and PPB-PEG-IFNγ significantly reduced TGFβ1-induced fibronectin, collagen I and collagen III mRNA expression, which was confirmed by immunohistochemistry. The PKCS model is a novel tool to test the pathophysiology of fibrosis and to screen the efficacy of anti-fibrotic drugs ex vivo in a multicellular and pro-fibrotic milieu. A major advantage of the slice model is that it can be used not only for animal but also for (fibrotic human kidney tissue.

  15. Real-time simulation of a Doubly-Fed Induction Generator based wind power system on eMEGASimRTM Real-Time Digital Simulator

    Science.gov (United States)

    Boakye-Boateng, Nasir Abdulai

    The growing demand for wind power integration into the generation mix prompts the need to subject these systems to stringent performance requirements. This study sought to identify the required tools and procedures needed to perform real-time simulation studies of Doubly-Fed Induction Generator (DFIG) based wind generation systems as basis for performing more practical tests of reliability and performance for both grid-connected and islanded wind generation systems. The author focused on developing a platform for wind generation studies and in addition, the author tested the performance of two DFIG models on the platform real-time simulation model; an average SimpowerSystemsRTM DFIG wind turbine, and a detailed DFIG based wind turbine using ARTEMiSRTM components. The platform model implemented here consists of a high voltage transmission system with four integrated wind farm models consisting in total of 65 DFIG based wind turbines and it was developed and tested on OPAL-RT's eMEGASimRTM Real-Time Digital Simulator.

  16. Evaluation of some thin-layer drying models of persimmon slices (Diospyros kaki L.)

    International Nuclear Information System (INIS)

    Doymaz, İbrahim

    2012-01-01

    Highlights: ► In this study, convective drying (50–70 °C) was applied as a preservation technology for persimmon slices. ► The highest drying and rehydration rates obtained with blanched slices. ► The Midilli et al., Page and Weibull models were determined as the suitable models. ► Effective moisture diffusivity, diffusivity constant and activation energy for drying process were determined. - Abstract: The effect of blanching and drying temperature (50, 60 and 70 °C) on drying kinetics and rehydration ratio of persimmons under hot-air drying was investigated. It was observed that both the drying temperature and blanching affected the drying time. The shortest drying times and highest rehydration ratios were obtained from blanched samples. Six thin-layer drying models were evaluated in the kinetics research. The fit quality of the proposed models was evaluated by using the determination of coefficient (R 2 ), reduced chi-square (χ 2 ) and root means square error (RMSE). The Midilli et al., Page and Weibull models showed a better fit to experimental drying data as compared to other models. Effective moisture diffusivity (D eff ) ranged from 7.05 × 10 −11 to 2.34 × 10 −10 m 2 /s calculated using the Fick’s second law. The activation energies of blanched and control samples determined from slope of the Arrhenius plot, ln(D eff ) versus 1/(T + 273.15), was 30.64 and 43.26 kJ/mol, respectively.

  17. A Unified Approach to Diffusion Direction Sensitive Slice Registration and 3-D DTI Reconstruction From Moving Fetal Brain Anatomy

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Seshamani, Sharmishtaa; Kroenke, Christopher

    2014-01-01

    to the underlying anatomy. Previous image registration techniques have been described to estimate the between slice fetal head motion, allowing the reconstruction of 3D a diffusion estimate on a regular grid using interpolation. We propose Approach to Unified Diffusion Sensitive Slice Alignment and Reconstruction...... (AUDiSSAR) that explicitly formulates a process for diffusion direction sensitive DW-slice-to-DTI-volume alignment. This also incorporates image resolution modeling to iteratively deconvolve the effects of the imaging point spread function using the multiple views provided by thick slices acquired...

  18. Recent developments in multi-wire fixed abrasive slicing technique (FAST). [for low cost silicon wafer production from ingots

    Science.gov (United States)

    Schmid, F.; Khattak, C. P.; Smith, M. B.; Lynch, L. D.

    1982-01-01

    Slicing is an important processing step for all technologies based on the use of ingots. A comparison of the economics of three slicing techniques shows that the fixed abrasive slicing technique (FAST) is superior to the internal diameter (ID) and the multiblade slurry (MBS) techniques. Factors affecting contact length are discussed, taking into account kerf width, rocking angle, ingot size, and surface speed. Aspects of blade development are also considered. A high concentration of diamonds on wire has been obtained in wire packs usd for FAST slicing. The material removal rate was found to be directly proportional to the pressure at the diamond tips.

  19. Simulating Real-Time Aspects of Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Christian Nastasi

    2010-01-01

    Full Text Available Wireless Sensor Networks (WSNs technology has been mainly used in the applications with low-frequency sampling and little computational complexity. Recently, new classes of WSN-based applications with different characteristics are being considered, including process control, industrial automation and visual surveillance. Such new applications usually involve relatively heavy computations and also present real-time requirements as bounded end-to- end delay and guaranteed Quality of Service. It becomes then necessary to employ proper resource management policies, not only for communication resources but also jointly for computing resources, in the design and development of such WSN-based applications. In this context, simulation can play a critical role, together with analytical models, for validating a system design against the parameters of Quality of Service demanded for. In this paper, we present RTNS, a publicly available free simulation tool which includes Operating System aspects in wireless distributed applications. RTNS extends the well-known NS-2 simulator with models of the CPU, the Real-Time Operating System and the application tasks, to take into account delays due to the computation in addition to the communication. We demonstrate the benefits of RTNS by presenting our simulation study for a complex WSN-based multi-view vision system for real-time event detection.

  20. Noise Simulation of Continuous-Time ΣΔ Modulators

    International Nuclear Information System (INIS)

    Arias, J.; Quintanilla, L.; Bisbal, D.; San Pablo, J.; Enriquez, L.; Vicente, J.; Barbolla, J.

    2005-01-01

    In this work, an approach for the simulation of the effect of noise sources in the performance of continuous-time ΔΣ modulators is presented. Electrical noise including thermal noise, 1/f noise and clock jitter are included in a simulation program and their impact on the system performance is analyzed

  1. Institut Gustave Roussy method for head and neck tumor treatment planning using simulator-CT images and radiographic film data; Methode utilisee a l'institut Gustave Roussy pour l'etablissement des plans de traitement des cancers ORL a partir des images de simulateur-scanneur et du film radiographique de profil

    Energy Technology Data Exchange (ETDEWEB)

    Bridier, A.; Barrois, M.M.; Rivet, P. [Institut Gustave Roussy, Service de Physique, 94 - Villejuif (France); Diaz, J.C.; Kafrouni, H.; Leclerc, A. [Institut Gustave Roussy, Activite Dosigray, 94 - Villejuif (France); Wibault, P.; Bourhis, J.; Eschwege, F. [Institut Gustave Roussy, Dept. de Radiotherapie, 94 - Villejuif (France)

    2001-06-01

    Institut Gustave Roussy method for head and neck tumor treatment planning using simulator-CT images and radiographic film data. The paper deals with the recent improvements introduced in the most usual method applied in the Institut Gustave Roussy radiotherapy department for obtaining the anatomical data of patients treated for head and neck tumors. For each of these patients, five to seven transverses slices and a lateral radiographic film are taken from a Mecaserto simulator-CT. The anatomical representation of the patient sagittal plane is carried out from the digitalization of the radiographic film on a Vidar Vxr-12 Plus film scanner and integrated into the Dosigray dose calculation programme in order to be used as a support for the laying out of the dose distribution in reference to the treatment. The sagittal anatomical representation obtained from the radiographic film digitalization is compared with the one resulting from the interpolation between a limited number of irregularly-spaced transverse slices taken on the simulator-CT. The method using the simulator-scanner transverse slices and the radiographic film digitalization represents an interesting alternative for obtaining an anatomy simulation representative of the patient in hospitals where a scanner is not available full-time for the needs of the radiotherapy process. (authors)

  2. [Preparation of simulate craniocerebral models via three dimensional printing technique].

    Science.gov (United States)

    Lan, Q; Chen, A L; Zhang, T; Zhu, Q; Xu, T

    2016-08-09

    Three dimensional (3D) printing technique was used to prepare the simulate craniocerebral models, which were applied to preoperative planning and surgical simulation. The image data was collected from PACS system. Image data of skull bone, brain tissue and tumors, cerebral arteries and aneurysms, and functional regions and relative neural tracts of the brain were extracted from thin slice scan (slice thickness 0.5 mm) of computed tomography (CT), magnetic resonance imaging (MRI, slice thickness 1mm), computed tomography angiography (CTA), and functional magnetic resonance imaging (fMRI) data, respectively. MIMICS software was applied to reconstruct colored virtual models by identifying and differentiating tissues according to their gray scales. Then the colored virtual models were submitted to 3D printer which produced life-sized craniocerebral models for surgical planning and surgical simulation. 3D printing craniocerebral models allowed neurosurgeons to perform complex procedures in specific clinical cases though detailed surgical planning. It offered great convenience for evaluating the size of spatial fissure of sellar region before surgery, which helped to optimize surgical approach planning. These 3D models also provided detailed information about the location of aneurysms and their parent arteries, which helped surgeons to choose appropriate aneurismal clips, as well as perform surgical simulation. The models further gave clear indications of depth and extent of tumors and their relationship to eloquent cortical areas and adjacent neural tracts, which were able to avoid surgical damaging of important neural structures. As a novel and promising technique, the application of 3D printing craniocerebral models could improve the surgical planning by converting virtual visualization into real life-sized models.It also contributes to functional anatomy study.

  3. SPATIOTEMPORAL VISUALIZATION OF TIME-SERIES SATELLITE-DERIVED CO2 FLUX DATA USING VOLUME RENDERING AND GPU-BASED INTERPOLATION ON A CLOUD-DRIVEN DIGITAL EARTH

    Directory of Open Access Journals (Sweden)

    S. Wu

    2017-10-01

    Full Text Available The ocean carbon cycle has a significant influence on global climate, and is commonly evaluated using time-series satellite-derived CO2 flux data. Location-aware and globe-based visualization is an important technique for analyzing and presenting the evolution of climate change. To achieve realistic simulation of the spatiotemporal dynamics of ocean carbon, a cloud-driven digital earth platform is developed to support the interactive analysis and display of multi-geospatial data, and an original visualization method based on our digital earth is proposed to demonstrate the spatiotemporal variations of carbon sinks and sources using time-series satellite data. Specifically, a volume rendering technique using half-angle slicing and particle system is implemented to dynamically display the released or absorbed CO2 gas. To enable location-aware visualization within the virtual globe, we present a 3D particlemapping algorithm to render particle-slicing textures onto geospace. In addition, a GPU-based interpolation framework using CUDA during real-time rendering is designed to obtain smooth effects in both spatial and temporal dimensions. To demonstrate the capabilities of the proposed method, a series of satellite data is applied to simulate the air-sea carbon cycle in the China Sea. The results show that the suggested strategies provide realistic simulation effects and acceptable interactive performance on the digital earth.

  4. X-radiography of slices of the Allende Meteorite

    Science.gov (United States)

    Smith, M. J.; Anderson, J. B.; Heymann, D.

    1984-01-01

    A 2.2 kg fragment of the Allende Meteorite was derinded and sliced by bandsawing. Several X-radiographs were made of all slices. The following features are resolved: grains of blocky troilite (bright spots), troilite rimmed chondrules (bright halos), chondrules with central vugs (dim halos), white aggregates (dark patches), and dark inclusions (medium dark patches). The number of FeS grains larger than about 0.5 mm is one per 6 + or - 1 gram of this fragment. Their concentration appears to be uniform at the 1 kg weight level, but is not uniform at the 100 g level. The number of FeS rimmed chondrules is one per 10 g. Their concentration is also nonuniform at the 100 g weight level. The number of white aggregates is roughly one per 20 g. These disc shaped objects show a distinct preferred orientation of the axis orthogonal to the plane of the disc. Chondrules with central vugs are numerous. Linear and curved arrays of chondrules, up to a few cm long, were observed. An interpretation of the observed features is given.

  5. Enhancement of DNA polymerase activity in potato tuber slices

    International Nuclear Information System (INIS)

    Watanabe, Akira; Imaseki, Hidemasa

    1977-01-01

    DNA polymerase was extracted from potato (Soleum tuberosum L.) tuber discs and the temporal correlation of its activity change to DNA synthesis in vivo was examined during aging of the discs. Most of the DNA polymerase was recovered as a bound form in the 18,000 x g precipitate. Reaction with the bound-form enzyme was dependent on the presence of four deoxynucleoside triphosphates, Mg 2+ , and a template. ''Activated'' DNA and heat-denatured DNA, but not native DNA, were utilized as templates. The polymerase activity was sensitive to SH reagents. Fresh discs, which do not synthesize DNA in vivo, contained a significant amount of DNA polymerase and its activity increased linearly with time until 48 hr after slicing and became four times that of fresh discs after 72 hr, whereas the activity of DNA synthesis in vivo increased with time and decreased after reaching a maximum at 30 hr. Cycloheximide inhibited the enhancement of polymerase activity. DNA polymerase from aged and fresh discs had identical requirements for deoxynucleotides and a template in their reactions, sensitivity to SH reagent, and affinity to thymidine triphosphate. (auth.)

  6. Simulated dose reduction by adding artificial noise to measured raw data: A validation study

    International Nuclear Information System (INIS)

    Soederberg, M.; Gunnarsson, M.; Nilsson, M.

    2010-01-01

    The purpose of this study was to verify and validate a noise simulation tool called Dose Tutor (VAMP GmbH) in terms of level and texture of the simulated noise. By adding artificial noise to measured computed tomography (CT) raw data, a scan acquired with a lower dose (mAs) than the actual one can be simulated. A homogeneous polyethylene phantom and an anthropomorphic chest phantom were scanned for different mAs levels, tube voltages, slice thicknesses and reconstruction kernels. The simulated noise levels were compared with the noise levels in real transverse slice images actually acquired with corresponding mAs values. In general, the noise comparisons showed acceptable agreement in magnitude (<20% deviation in pixel standard deviation). Also, the calculated noise power spectra were similar, which indicates that the noise texture is correctly reproduced. In conclusion, this study establishes that the Dose Tutor might be a useful tool for estimating the dose reduction potential for CT protocols. (authors)

  7. Real-time Executive for a basic principle simulator

    International Nuclear Information System (INIS)

    Buerger, L.; Szegi, Zs.; Vegh, E.

    1987-09-01

    A basic principle simulator for WWER-440 type nuclear power plants is under development in the Central Research Institute for Physics, Budapest. So far the technological models of both to primary and secondary circuits are ready and this paper presents the Real-time Executive and the on-line operating environment which controls the simulator. This executive system contains eight programs and the detailed structure of the data base is presented. The control of the execution of the model programs, their timing and the error recoveries are also discussed. (author) 5 refs

  8. Long-term brain slice culturing in a microfluidic platform

    DEFF Research Database (Denmark)

    Vedarethinam, Indumathi; Avaliani, N.; Tønnesen, J.

    2011-01-01

    In this work, we present the development of a transparent poly(methyl methacrylate) (PMMA) based microfluidic culture system for handling long-term brain slice cultures independent of an incubator. The different stages of system development have been validated by culturing GFP producing brain sli...

  9. A sandwich-like differential B-dot based on EACVD polycrystalline diamond slice

    Science.gov (United States)

    Xu, P.; Yu, Y.; Xu, L.; Zhou, H. Y.; Qiu, C. J.

    2018-06-01

    In this article, we present a method of mass production of a standardized high-performance differential B-dot magnetic probe together with the magnetic field measurement in a pulsed current device with the current up to hundreds of kilo-Amperes. A polycrystalline diamond slice produced in an Electron Assisted Chemical Vapor Deposition device is used as the base and insulating material to imprint two symmetric differential loops for the magnetic field measurement. The SP3 carbon bond in the cubic lattice structure of diamond is confirmed by Raman spectra. The thickness of this slice is 20 μm. A gold loop is imprinted onto each surface of the slice by using the photolithography technique. The inner diameter, width, and thickness of each loop are 0.8 mm, 50 μm, and 1 μm, respectively. It provides a way of measuring the pulsed magnetic field with a high spatial and temporal resolution, especially in limited space. This differential magnetic probe has demonstrated a very good common-mode rejection rate through the pulsed magnetic field measurement.

  10. Application of gamma irradiation for the microbiological safety of sliced cheddar cheese

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Song, Beom Seok; Kim, Jae Hun; Choi, Jong Ill; Lee, Ju Woon; Byun, Myung Woo [Radiation Research Center for Innovative Technology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Jo, Cheo Run [Dept. of Animal Science and Biotechnology, Chungnam National University, Daejeon (Korea, Republic of)

    2007-05-15

    This study was conducted to establish the microbiological safety of sliced cheddar cheese with gamma irradiation. Total aerobic bacteria was 2.50 Log CFUg-1 in non-irradiated sample. No viable cells were observed in the gamma-irradiated at 1 kGy and over. D10 value for Listeria monocytogenes and Staphylococcus aureus inoculated in sliced cheddar cheese were 0.64 and 0.54 kGy, respectively. TBARS (2-thiobarbituric acid reactive substances) values were increased as irradiation dose was increased, but there was no significant difference between nonirradiated and irradiated samples at 1 kGy. Sensory evaluation showed there was no significant difference between samples irradiated at 1 kGy and non-irradiated in respect of color, odor, overall acceptability. Theses results indicated that gamma irradiation at 1 kGy was considered to be an effective treatment to ensure the microbiological safety of sliced cheddar cheese with minimal change of sensory, even though further studies should be investigated to reduce the deterioration of sensory quality induced by gamma irradiation.

  11. Real time simulation of large systems on mini-computer

    International Nuclear Information System (INIS)

    Nakhle, Michel; Roux, Pierre.

    1979-01-01

    Most simulation languages will only accept an explicit formulation of differential equations, and logical variables hold no special status therein. The pace of the suggested methods of integration is limited by the smallest time constant of the model submitted. The NEPTUNIX 2 simulation software has a language that will take implicit equations and an integration method of which the variable pace is not limited by the time constants of the model. This, together with high time and memory ressources optimization of the code generated, makes NEPTUNIX 2 a basic tool for simulation on mini-computers. Since the logical variables are specific entities under centralized control, correct processing of discontinuities and synchronization with a real process are feasible. The NEPTUNIX 2 is the industrial version of NEPTUNIX 1 [fr

  12. Finite Difference Time Domain (FDTD) Simulations Using Graphics Processors

    National Research Council Canada - National Science Library

    Adams, Samuel; Payne, Jason; Boppana, Rajendra

    2007-01-01

    .... This paper shows how GPUs can be used to greatly speedup FDTD simulations. The main objective is to leverage GPU processing power for FDTD update calculations and complete computationally expensive simulations in reasonable time...

  13. A slice through a prototype LHC bending magnet

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This slice through a prototype LHC magnet clearly shows the superconducting cable in several blocks around the central hole – the beam pipe in which the LHC’s accelerated beams will travel. Magnet design is crucial to the LHC’s success and this sample is among the first to be built to the final cable configuration.

  14. Holographic complexity for time-dependent backgrounds

    Energy Technology Data Exchange (ETDEWEB)

    Momeni, Davood, E-mail: davoodmomeni78@gmail.com [Eurasian International Center for Theoretical Physics and Department of General Theoretical Physics, Eurasian National University, Astana 010008 (Kazakhstan); Faizal, Mir, E-mail: mirfaizalmir@googlemail.com [Irving K. Barber School of Arts and Sciences, University of British Columbia, Okanagan, 3333 University Way, Kelowna, British Columbia V1V 1V7 (Canada); Department of Physics and Astronomy, University of Lethbridge, Lethbridge, Alberta, T1K 3M4 (Canada); Bahamonde, Sebastian, E-mail: sebastian.beltran.14@ucl.ac.uk [Department of Mathematics, University College London, Gower Street, London, WC1E 6BT (United Kingdom); Myrzakulov, Ratbay [Eurasian International Center for Theoretical Physics and Department of General Theoretical Physics, Eurasian National University, Astana 010008 (Kazakhstan)

    2016-11-10

    In this paper, we will analyze the holographic complexity for time-dependent asymptotically AdS geometries. We will first use a covariant zero mean curvature slicing of the time-dependent bulk geometries, and then use this co-dimension one spacelike slice of the bulk spacetime to define a co-dimension two minimal surface. The time-dependent holographic complexity will be defined using the volume enclosed by this minimal surface. This time-dependent holographic complexity will reduce to the usual holographic complexity for static geometries. We will analyze the time-dependence as a perturbation of the asymptotically AdS geometries. Thus, we will obtain time-dependent asymptotically AdS geometries, and we will calculate the holographic complexity for such time-dependent geometries.

  15. Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

    Science.gov (United States)

    Ma, Dan; Coppo, Simone; Chen, Yong; McGivney, Debra F; Jiang, Yun; Pahwa, Shivani; Gulani, Vikas; Griswold, Mark A

    2017-11-01

    The goal of this study is to characterize and improve the accuracy of 2D magnetic resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B 1 imperfections, which are two main factors that affect quantitative results in MRF. The SP and B 1 imperfections are characterized and corrected separately. The SP effect is corrected by simulating the radiofrequency pulse in the dictionary, and the B 1 is corrected by acquiring a B 1 map using the Bloch-Siegert method before each scan. The accuracy, precision, and repeatability of the proposed method are evaluated in phantom studies. The effects of both SP and B 1 imperfections are also illustrated and corrected in the in vivo studies. The SP and B 1 corrections improve the accuracy of the T 1 and T 2 values, independent of the shape of the radiofrequency pulse. The T 1 and T 2 values obtained from different excitation patterns become more consistent after corrections, which leads to an improvement of the robustness of the MRF design. This study demonstrates that MRF is sensitive to both SP and B 1 effects, and that corrections can be made to improve the accuracy of MRF with only a 2-s increase in acquisition time. Magn Reson Med 78:1781-1789, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Modulation of methylmercury uptake by methionine: Prevention of mitochondrial dysfunction in rat liver slices by a mimicry mechanism

    International Nuclear Information System (INIS)

    Roos, Daniel Henrique; Puntel, Robson Luiz; Farina, Marcelo; Aschner, Michael; Bohrer, Denise; Rocha, Joao Batista T.; Vargas Barbosa, Nilda B. de

    2011-01-01

    Methylmercury (MeHg) is an ubiquitous environmental pollutant which is transported into the mammalian cells when present as the methylmercury-cysteine conjugate (MeHg-Cys). With special emphasis on hepatic cells, due to their particular propensity to accumulate an appreciable amount of Hg after exposure to MeHg, this study was performed to evaluate the effects of methionine (Met) on Hg uptake, reactive species (RS) formation, oxygen consumption and mitochondrial function/cellular viability in both liver slices and mitochondria isolated from these slices, after exposure to MeHg or the MeHg-Cys complex. The liver slices were pre-treated with Met (250 μM) 15 min before being exposed to MeHg (25 μM) or MeHg-Cys (25 μM each) for 30 min at 37 o C. The treatment with MeHg caused a significant increase in the Hg concentration in both liver slices and mitochondria isolated from liver slices. Moreover, the Hg uptake was higher in the group exposed to the MeHg-Cys complex. In the DCF (dichlorofluorescein) assay, the exposure to MeHg and MeHg-Cys produced a significant increase in DFC reactive species (DFC-RS) formation only in the mitochondria isolated from liver slices. As observed with Hg uptake, DFC-RS levels were significantly higher in the mitochondria treated with the MeHg-Cys complex compared to MeHg alone. MeHg exposure also caused a marked decrease in the oxygen consumption of liver slices when compared to the control group, and this effect was more pronounced in the liver slices treated with the MeHg-Cys complex. Similarly, the loss of mitochondrial activity/cell viability was greater in liver slices exposed to the MeHg-Cys complex when compared to slices treated only with MeHg. In all studied parameters, Met pre-treatment was effective in preventing the MeHg- and/or MeHg-Cys-induced toxicity in both liver slices and mitochondria. Part of the protection afforded by Met against MeHg may be related to a direct interaction with MeHg or to the competition of Met with

  17. Time Shared Optical Network (TSON): a novel metro architecture for flexible multi-granular services.

    Science.gov (United States)

    Zervas, Georgios S; Triay, Joan; Amaya, Norberto; Qin, Yixuan; Cervelló-Pastor, Cristina; Simeonidou, Dimitra

    2011-12-12

    This paper presents the Time Shared Optical Network (TSON) as metro mesh network architecture for guaranteed, statistically-multiplexed services. TSON proposes a flexible and tunable time-wavelength assignment along with one-way tree-based reservation and node architecture. It delivers guaranteed sub-wavelength and multi-granular network services without wavelength conversion, time-slice interchange and optical buffering. Simulation results demonstrate high network utilization, fast service delivery, and low end-to-end delay on a contention-free sub-wavelength optical transport network. In addition, implementation complexity in terms of Layer 2 aggregation, grooming and optical switching has been evaluated. © 2011 Optical Society of America

  18. Just-in-time Time Data Analytics and Visualization of Climate Simulations using the Bellerophon Framework

    Science.gov (United States)

    Anantharaj, V. G.; Venzke, J.; Lingerfelt, E.; Messer, B.

    2015-12-01

    Climate model simulations are used to understand the evolution and variability of earth's climate. Unfortunately, high-resolution multi-decadal climate simulations can take days to weeks to complete. Typically, the simulation results are not analyzed until the model runs have ended. During the course of the simulation, the output may be processed periodically to ensure that the model is preforming as expected. However, most of the data analytics and visualization are not performed until the simulation is finished. The lengthy time period needed for the completion of the simulation constrains the productivity of climate scientists. Our implementation of near real-time data visualization analytics capabilities allows scientists to monitor the progress of their simulations while the model is running. Our analytics software executes concurrently in a co-scheduling mode, monitoring data production. When new data are generated by the simulation, a co-scheduled data analytics job is submitted to render visualization artifacts of the latest results. These visualization output are automatically transferred to Bellerophon's data server located at ORNL's Compute and Data Environment for Science (CADES) where they are processed and archived into Bellerophon's database. During the course of the experiment, climate scientists can then use Bellerophon's graphical user interface to view animated plots and their associated metadata. The quick turnaround from the start of the simulation until the data are analyzed permits research decisions and projections to be made days or sometimes even weeks sooner than otherwise possible! The supercomputer resources used to run the simulation are unaffected by co-scheduling the data visualization jobs, so the model runs continuously while the data are visualized. Our just-in-time data visualization software looks to increase climate scientists' productivity as climate modeling moves into exascale era of computing.

  19. Variable slip wind generator modeling for real-time simulation

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, R.; Brochu, J.; Turmel, G. [Hydro-Quebec, Varennes, PQ (Canada). IREQ

    2006-07-01

    A model of a wind turbine using a variable slip wound-rotor induction machine was presented. The model was created as part of a library of generic wind generator models intended for wind integration studies. The stator winding of the wind generator was connected directly to the grid and the rotor was driven by the turbine through a drive train. The variable resistors was synthesized by an external resistor in parallel with a diode rectifier. A forced-commutated power electronic device (IGBT) was connected to the wound rotor by slip rings and brushes. Simulations were conducted in a Matlab/Simulink environment using SimPowerSystems blocks to model power systems elements and Simulink blocks to model the turbine, control system and drive train. Detailed descriptions of the turbine, the drive train and the control system were provided. The model's implementation in the simulator was also described. A case study demonstrating the real-time simulation of a wind generator connected at the distribution level of a power system was presented. Results of the case study were then compared with results obtained from the SimPowerSystems off-line simulation. Results showed good agreement between the waveforms, demonstrating the conformity of the real-time and the off-line simulations. The capability of Hypersim for real-time simulation of wind turbines with power electronic converters in a distribution network was demonstrated. It was concluded that hardware-in-the-loop (HIL) simulation of wind turbine controllers for wind integration studies in power systems is now feasible. 5 refs., 1 tab., 6 figs.

  20. Simulating continuous-time Hamiltonian dynamics by way of a discrete-time quantum walk

    International Nuclear Information System (INIS)

    Schmitz, A.T.; Schwalm, W.A.

    2016-01-01

    Much effort has been made to connect the continuous-time and discrete-time quantum walks. We present a method for making that connection for a general graph Hamiltonian on a bigraph. Furthermore, such a scheme may be adapted for simulating discretized quantum models on a quantum computer. A coin operator is found for the discrete-time quantum walk which exhibits the same dynamics as the continuous-time evolution. Given the spectral decomposition of the graph Hamiltonian and certain restrictions, the discrete-time evolution is solved for explicitly and understood at or near important values of the parameters. Finally, this scheme is connected to past results for the 1D chain. - Highlights: • A discrete-time quantum walk is purposed which approximates a continuous-time quantum walk. • The purposed quantum walk could be used to simulate Hamiltonian dynamics on a quantum computer. • Given the spectra decomposition of the Hamiltonian, the quantum walk is solved explicitly. • The method is demonstrated and connected to previous work done on the 1D chain.

  1. Chemical, biochemical, and microbiological aspects of chitosan quaternary salt as active coating on sliced apples

    Directory of Open Access Journals (Sweden)

    Douglas de Britto

    2012-09-01

    Full Text Available The biocompatibility of chitosan and chitosan quaternary salt coatings was evaluated for use as edible coatings for sliced apple. Measurement of water loss, color change, and fungal growth appearance were monitored as a function of time. A significant brownish effect was observed on chitosan coated slices, varying greatly from L* = 76.5 and Hue angle = 95.9° (t = 0 to L* = 45.3 and Hue angle = 69.8° (t = 3 days, whilst for TMC coated samples the variation was considerable lower (L* = 74.1; Hue angle = 95.0° to (L* = 67.0; Hue angle = 83.8° within the same period. The hydrosoluble derivative N,N,N-trimethylchitosan demonstrated good antifungal activity against P. expansum although highly dependent on the polymer properties such as degree of quaternization. The most efficient formulation was that prepared from derivative having a degree of quaternization of 45%, high solubility, and high viscosity. This formulation restrained fungus spreading up to 30%, while for the control it reached almost 80% of the total assessed surfaces during 7 days of storage.

  2. Analysis of Time Discretization and its Effect on Simulation Processes

    Directory of Open Access Journals (Sweden)

    Gilbert-Rainer Gillich

    2006-10-01

    Full Text Available The paper presents the influence of time discretization on the results of simulations of technical systems. In this sense the systems are mod-eled using the SciLab/SCICOS environment, using different time inter-vals. Ulterior the processes are simulated and the results are com-pared.

  3. GDNF and neublastin protect against NMDA-induced excitotoxicity in hippocampal slice cultures

    DEFF Research Database (Denmark)

    Bonde, C; Kristensen, B W; Blaabjerg, M

    2000-01-01

    -producing HiB5 cells, were added to slice cultures I h before exposure to 10 microM NMDA for 48h. Neuronal cell death was monitored, before and during the NMDA exposure, by densitometric measurements of propidium iodide (PI) uptake and loss of Nissl staining. Both the addition of rhGDNF and NBN......The potential neuroprotective effects of glial cell line-derived neurotrophic factor (GDNF) and neublastin (NBN) against NMDA-induced excitotoxicity were examined in hippocampal brain slice cultures. Recombinant human GDNF (25-100 ng/ ml) or NBN, in medium conditioned by growth of transfected, NBN...

  4. Real-time simulator for designing electron dual scattering foil systems.

    Science.gov (United States)

    Carver, Robert L; Hogstrom, Kenneth R; Price, Michael J; LeBlanc, Justin D; Pitcher, Garrett M

    2014-11-08

    The purpose of this work was to develop a user friendly, accurate, real-time com- puter simulator to facilitate the design of dual foil scattering systems for electron beams on radiotherapy accelerators. The simulator allows for a relatively quick, initial design that can be refined and verified with subsequent Monte Carlo (MC) calculations and measurements. The simulator also is a powerful educational tool. The simulator consists of an analytical algorithm for calculating electron fluence and X-ray dose and a graphical user interface (GUI) C++ program. The algorithm predicts electron fluence using Fermi-Eyges multiple Coulomb scattering theory with the reduced Gaussian formalism for scattering powers. The simulator also estimates central-axis and off-axis X-ray dose arising from the dual foil system. Once the geometry of the accelerator is specified, the simulator allows the user to continuously vary primary scattering foil material and thickness, secondary scat- tering foil material and Gaussian shape (thickness and sigma), and beam energy. The off-axis electron relative fluence or total dose profile and central-axis X-ray dose contamination are computed and displayed in real time. The simulator was validated by comparison of off-axis electron relative fluence and X-ray percent dose profiles with those calculated using EGSnrc MC. Over the energy range 7-20 MeV, using present foils on an Elekta radiotherapy accelerator, the simulator was able to reproduce MC profiles to within 2% out to 20 cm from the central axis. The central-axis X-ray percent dose predictions matched measured data to within 0.5%. The calculation time was approximately 100 ms using a single Intel 2.93 GHz processor, which allows for real-time variation of foil geometrical parameters using slider bars. This work demonstrates how the user-friendly GUI and real-time nature of the simulator make it an effective educational tool for gaining a better understanding of the effects that various system

  5. A Multiscale Simulation Method and Its Application to Determine the Mechanical Behavior of Heterogeneous Geomaterials

    Directory of Open Access Journals (Sweden)

    Shengwei Li

    2017-01-01

    Full Text Available To study the micro/mesomechanical behaviors of heterogeneous geomaterials, a multiscale simulation method that combines molecular simulation at the microscale, a mesoscale analysis of polished slices, and finite element numerical simulation is proposed. By processing the mesostructure images obtained from analyzing the polished slices of heterogeneous geomaterials and mapping them onto finite element meshes, a numerical model that more accurately reflects the mesostructures of heterogeneous geomaterials was established by combining the results with the microscale mechanical properties of geomaterials obtained from the molecular simulation. This model was then used to analyze the mechanical behaviors of heterogeneous materials. Because kernstone is a typical heterogeneous material that comprises many types of mineral crystals, it was used for the micro/mesoscale mechanical behavior analysis in this paper using the proposed method. The results suggest that the proposed method can be used to accurately and effectively study the mechanical behaviors of heterogeneous geomaterials at the micro/mesoscales.

  6. Real-time maritime scene simulation for ladar sensors

    Science.gov (United States)

    Christie, Chad L.; Gouthas, Efthimios; Swierkowski, Leszek; Williams, Owen M.

    2011-06-01

    Continuing interest exists in the development of cost-effective synthetic environments for testing Laser Detection and Ranging (ladar) sensors. In this paper we describe a PC-based system for real-time ladar scene simulation of ships and small boats in a dynamic maritime environment. In particular, we describe the techniques employed to generate range imagery accompanied by passive radiance imagery. Our ladar scene generation system is an evolutionary extension of the VIRSuite infrared scene simulation program and includes all previous features such as ocean wave simulation, the physically-realistic representation of boat and ship dynamics, wake generation and simulation of whitecaps, spray, wake trails and foam. A terrain simulation extension is also under development. In this paper we outline the development, capabilities and limitations of the VIRSuite extensions.

  7. Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer

    International Nuclear Information System (INIS)

    Bornstein, B.A.; Cheng, C.W.; Rhodes, L.M.; Rashid, H.; Stomper, P.C.; Siddon, R.L.; Harris, J.R.

    1990-01-01

    A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex to base. The ipsilateral total lung area and the lung area included within the treatment port were calculated for each CT scan slice, multiplied by the slice thickness, and then integrated over all CT scan slices to give the volumes. The best predictor of the percent of ipsilateral lung volume treated by the tangential fields was the CLD. Employing linear regression analysis, a coefficient of determination r2 = 0.799 was calculated between CLD and percent treated ipsilateral lung volume on CT scan. In comparison, the coefficients for the other parameters were r2 = 0.784 for the MLD, r2 = 0.071 for L, and r2 = 0.690 for CLD x L. A CLD of 1.5 cm predicted that about 6% of the ipsilateral lung would be included in the tangential field, a CLD of 2.5 cm about 16%, and a CLD of 3.5 cm about 26% of the ipsilateral lung, with a mean 90% prediction interval of +/- 7.1% of ipsilateral lung volume

  8. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  9. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    Energy Technology Data Exchange (ETDEWEB)

    Khalvati, Farzad, E-mail: farzad.khalvati@uwaterloo.ca; Tizhoosh, Hamid R. [Department of Systems Design Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada); Salmanpour, Aryan; Rahnamayan, Shahryar [Department of Engineering and Applied Science, University of Ontario Institute of Technology, Oshawa, Ontario L1H 7K4 (Canada); Rodrigues, George [Department of Radiation Oncology, London Regional Cancer Program, London, Ontario N6C 2R6, Canada and Department of Epidemiology/Biostatistics, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2013-12-15

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

  10. Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

    International Nuclear Information System (INIS)

    Khalvati, Farzad; Tizhoosh, Hamid R.; Salmanpour, Aryan; Rahnamayan, Shahryar; Rodrigues, George

    2013-01-01

    Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability

  11. Effects of chemotherapeutics on organotypic corticostriatal slice cultures identified by a panel of fluorescent and immunohistochemical markers

    DEFF Research Database (Denmark)

    Nørregaard, Annette; Jensen, Stine Skov; Kolenda, Jesper

    2012-01-01

    no toxicity was observed. Corresponding immunostaining showed loss of MAP2 and increased expression of GFAP and p25α for cultures exposed to 1,000 nM VCR. Cultures exposed to high concentrations of ACNU and IM disintegrated, leaving no tissue for histology. In conclusion, corticostriatal slice cultures...... specific neuronal and glial degeneration induced by chemotherapeutics in organotypic rat corticostriatal slice cultures. The slice cultures were exposed to the alkylating agents temozolomide (TMZ) and nimustine (ACNU), the tyrosine kinase inhibitor imatinib mesylate (IM) and the microtubule...

  12. The Sliced Pineapple Grid Feature for Predicting Grasping Affordances

    DEFF Research Database (Denmark)

    Thomsen, Mikkel Tang; Kraft, Dirk; Krüger, Norbert

    2017-01-01

    The problem of grasping unknown objects utilising vision is addressed in this work by introducing a novel feature, the Sliced Pineapple Grid Feature (SPGF). The SPGF encode semi-local surfaces and allows for distinguishing structures such as “walls”,“edges” and “rims”. These structures are shown...

  13. CUDA-based real time surgery simulation.

    Science.gov (United States)

    Liu, Youquan; De, Suvranu

    2008-01-01

    In this paper we present a general software platform that enables real time surgery simulation on the newly available compute unified device architecture (CUDA)from NVIDIA. CUDA-enabled GPUs harness the power of 128 processors which allow data parallel computations. Compared to the previous GPGPU, it is significantly more flexible with a C language interface. We report implementation of both collision detection and consequent deformation computation algorithms. Our test results indicate that the CUDA enables a twenty times speedup for collision detection and about fifteen times speedup for deformation computation on an Intel Core 2 Quad 2.66 GHz machine with GeForce 8800 GTX.

  14. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    Science.gov (United States)

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  15. Effect of dentin bonding agent diffusing through dentin slices on the reactive oxygen species production and apoptosis of pulpal cells

    Directory of Open Access Journals (Sweden)

    Bor-Shiunn Lee

    2015-04-01

    Conclusion: The three DBAs after diffusion through 0.2- or 0.5-mm dentin slice still exhibit cytotoxicity to dental pulp cells. However, the 0.5-mm dentin slice is found to be a better barrier than the 0.2-mm dentin slice to protect dental pulp cells from DBA-induced cytotoxicity.

  16. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans

    Directory of Open Access Journals (Sweden)

    Alizé Lacoste Jeanson

    2017-05-01

    Full Text Available Background Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. Methods We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT and lean tissue (LT in such material. An intra-class correlation coefficient (ICC was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS linear regressions and support vector machine regression (SVMR. Results and Discussion The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5 and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77 than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08 for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  17. Body composition estimation from selected slices: equations computed from a new semi-automatic thresholding method developed on whole-body CT scans.

    Science.gov (United States)

    Lacoste Jeanson, Alizé; Dupej, Ján; Villa, Chiara; Brůžek, Jaroslav

    2017-01-01

    Estimating volumes and masses of total body components is important for the study and treatment monitoring of nutrition and nutrition-related disorders, cancer, joint replacement, energy-expenditure and exercise physiology. While several equations have been offered for estimating total body components from MRI slices, no reliable and tested method exists for CT scans. For the first time, body composition data was derived from 41 high-resolution whole-body CT scans. From these data, we defined equations for estimating volumes and masses of total body AT and LT from corresponding tissue areas measured in selected CT scan slices. We present a new semi-automatic approach to defining the density cutoff between adipose tissue (AT) and lean tissue (LT) in such material. An intra-class correlation coefficient (ICC) was used to validate the method. The equations for estimating the whole-body composition volume and mass from areas measured in selected slices were modeled with ordinary least squares (OLS) linear regressions and support vector machine regression (SVMR). The best predictive equation for total body AT volume was based on the AT area of a single slice located between the 4th and 5th lumbar vertebrae (L4-L5) and produced lower prediction errors (|PE| = 1.86 liters, %PE = 8.77) than previous equations also based on CT scans. The LT area of the mid-thigh provided the lowest prediction errors (|PE| = 2.52 liters, %PE = 7.08) for estimating whole-body LT volume. We also present equations to predict total body AT and LT masses from a slice located at L4-L5 that resulted in reduced error compared with the previously published equations based on CT scans. The multislice SVMR predictor gave the theoretical upper limit for prediction precision of volumes and cross-validated the results.

  18. Unbiased stereological estimation of d-dimensional volume in Rn from an isotropic random slice through a fixed point

    DEFF Research Database (Denmark)

    Jensen, Eva B. Vedel; Kiêu, K

    1994-01-01

    Unbiased stereological estimators of d-dimensional volume in R(n) are derived, based on information from an isotropic random r-slice through a specified point. The content of the slice can be subsampled by means of a spatial grid. The estimators depend only on spatial distances. As a fundamental ...... lemma, an explicit formula for the probability that an isotropic random r-slice in R(n) through 0 hits a fixed point in R(n) is given....

  19. Liver slices in in vitro pharmacotoxicology with special reference to the use of human liver tissue

    NARCIS (Netherlands)

    Olinga, Peter; Meijer, D.K F; Slooff, M.JH; Groothuis, Geny

    In the early years of research in in vitro pharmacotoxicology liver slices have been used. After a decline in the application of slices in favour of the use of isolated hepatocytes and the isolated perfused liver preparation, the development of the Krumdieck slicer in the 1980s led to a 'comeback'

  20. Implementation of SoC Based Real-Time Electromagnetic Transient Simulator

    Directory of Open Access Journals (Sweden)

    I. Herrera-Leandro

    2017-01-01

    Full Text Available Real-time electromagnetic transient simulators are important tools in the design stage of new control and protection systems for power systems. Real-time simulators are used to test and stress new devices under similar conditions that the device will deal with in a real network with the purpose of finding errors and bugs in the design. The computation of an electromagnetic transient is complex and computationally demanding, due to features such as the speed of the phenomenon, the size of the network, and the presence of time variant and nonlinear elements in the network. In this work, the development of a SoC based real-time and also offline electromagnetic transient simulator is presented. In the design, the required performance is met from two sides, (a using a technique to split the power system into smaller subsystems, which allows parallelizing the algorithm, and (b with specialized and parallel hardware designed to boost the solution flow. The results of this work have shown that for the proposed case studies, based on a balanced distribution of the node of subsystems, the proposed approach has decreased the total simulation time by up to 99 times compared with the classical approach running on a single high performance 32-bit embedded processor ARM-Cortex A9.

  1. Long-term potentiation protects rat hippocampal slices from the effects of acute hypoxia.

    Science.gov (United States)

    Youssef, F F; Addae, J I; McRae, A; Stone, T W

    2001-07-13

    We have previously shown that long-term potentiation (LTP) decreases the sensitivity of glutamate receptors in the rat hippocampal CA1 region to exogenously applied glutamate agonists. Since the pathophysiology of hypoxia/ischemia involves increased concentration of endogenous glutamate, we tested the hypothesis that LTP could reduce the effects of hypoxia in the hippocampal slice. The effects of LTP on hypoxia were measured by the changes in population spike potentials (PS) or field excitatory post-synaptic potentials (fepsps). Hypoxia was induced by perfusing the slice with (i) artificial CSF which had been pre-gassed with 95%N2/5% CO2; (ii) artificial CSF which had not been pre-gassed with 95% O2/5% CO2; or (iii) an oxygen-glucose deprived (OGD) medium which was similar to (ii) and in which the glucose had been replaced with sucrose. Exposure of a slice to a hypoxic medium for 1.5-3.0 min led to a decrease in the PS or fepsps; the potentials recovered to control levels within 3-5 min. Repeat exposure, 45 min later, of the same slice to the same hypoxic medium for the same duration as the first exposure caused a reduction in the potentials again; there were no significant differences between the degree of reduction caused by the first or second exposure for all three types of hypoxic media (P>0.05; paired t-test). In some of the slices, two episodes of LTP were induced 25 and 35 min after the first hypoxic exposure; this caused inhibition of reduction in potentials caused by the second hypoxic insult which was given at 45 min after the first; the differences in reduction in potentials were highly significant for all the hypoxic media used (Peffects of LTP were not prevented by cyclothiazide or inhibitors of NO synthetase compounds that have been shown to be effective in blocking the effects of LTP on the actions of exogenously applied AMPA and NMDA, respectively. The neuroprotective effects of LTP were similar to those of propentofylline, a known neuroprotective

  2. The slice balance approach (SBA): a characteristic-based, multiple balance SN approach on unstructured polyhedral meshes

    International Nuclear Information System (INIS)

    Grove, R.E.

    2005-01-01

    The Slice Balance Approach (SBA) is an approach for solving geometrically-complex, neutral-particle transport problems within a multi-group discrete ordinates (S N ) framework. The salient feature is an angle-dependent spatial decomposition. We approximate general surfaces with arbitrary polygonal faces and mesh the geometry with arbitrarily-shaped polyhedral cells. A cell-local spatial decomposition divides cells into angle-dependent slices for each S N direction. This subdivision follows from a characteristic-based view of the transport problem. Most balance-based characteristic methods use it implicitly; we use it explicitly and exploit its properties. Our mathematical approach is a multiple balance approach using exact spatial moments balance equations on cells and slices along with auxiliary relations on slices. We call this the slice balance approach; it is a characteristic-based multiple balance approach. The SBA is intentionally general and can extend differencing schemes to arbitrary 2-D and 3-D meshes. This work contributes to development of general-geometry deterministic transport capability to complement Monte Carlo capability for large, geometrically-complex transport problems. The purpose of this paper is to describe the SBA. We describe the spatial decomposition and mathematical framework and highlight a few interesting properties. We sketch the derivation of two solution schemes, a step characteristic scheme and a diamond-difference-like scheme, to illustrate the approach and we present interesting results for a 2-D problem. (author)

  3. An FFT-accelerated time-domain multiconductor transmission line simulator

    KAUST Repository

    Bagci, Hakan

    2010-02-01

    A fast time-domain multiconductor transmission line (MTL) simulator for analyzing general MTL networks is presented. The simulator models the networks as homogeneous MTLs that are excited by external fields and driven/terminated/ connected by potentially nonlinear lumped circuitry. It hybridizes an MTL solver derived from time-domain integral equations (TDIEs) in unknown wave coefficients for each MTL with a circuit solver rooted in modified nodal analysis equations in unknown node voltages and voltage-source currents for each circuit. These two solvers are rigorously interfaced at MTL and circuit terminals, and the resulting coupled system of equations is solved simultaneously for all MTL and circuit unknowns at each time step. The proposed simulator is amenable to hybridization, is fast Fourier transform (FFT)-accelerated, and is highly accurate: 1) It can easily be hybridized with TDIE-based field solvers (in a fully rigorous mathematical framework) for performing electromagnetic interference and compatibility analysis on electrically large and complex structures loaded with MTL networks. 2) It is accelerated by an FFT algorithm that calculates temporal convolutions of time-domain MTL Green functions in only O(Ntlog2 N t) rather than O(Ntt2) operations, where N t is the number of time steps of simulation. Moreover, the algorithm, which operates on temporal samples of MTL Green functions, is indifferent to the method used to obtain them. 3) It approximates MTL voltages, currents, and wave coefficients, using high-order temporal basis functions. Various numerical examples, including the crosstalk analysis of a (twisted) unshielded twisted-pair (UTP)-CAT5 cable and the analysis of field coupling into UTP-CAT5 and RG-58 cables located on an airplane, are presented to demonstrate the accuracy, efficiency, and versatility of the proposed simulator. © 2010 IEEE.

  4. Radioisotopic investigations of zinc uptake into brain slices

    International Nuclear Information System (INIS)

    Howell, G.A.

    1983-01-01

    The presence of zinc in the vicinity of the hippocampal mossy fibers has been repeatedly demonstrated, and several lines of evidence suggest that the mossy-fiber zinc is concentrated within the terminals of mossy fibers. In search of insight into the metabolism and function of mossy-fiber zinc, the present study investigated the transport of zinc into tissue slices and the response of the zinc transport to depolarization. Kinetic analysis of zinc accumulation by mouse brain slices in vitro revealed the presence of a high affinity uptake component with an apparent Km of 17.7 μM for hippocampus, 16.6 μM< for cortex and 25 μM for striatum and a V/sub max/ of 9.2 ng/mg/hr for the hippocampus, 10.1 ng/mg/hr for cortex and 9.6 ng/mg/hr for striatum. Cytoarchitectonic differences in zinc transport between the different hippocampal subregions were found with those regions containing granule cells or mossy fiber axons accumulating greater amounts of zinc than the CA 1 region. The present finding that mossy-fiber neuropil selectivity accumulates zinc suggests the presence of a zinc-binding substance unique to mossy-fiber tissue

  5. Precision cut lung slices as an efficient tool for in vitro lung physio-pharmacotoxicology studies.

    Science.gov (United States)

    Morin, Jean-Paul; Baste, Jean-Marc; Gay, Arnaud; Crochemore, Clément; Corbière, Cécile; Monteil, Christelle

    2013-01-01

    1.We review the specific approaches for lung tissue slices preparation and incubation systems and the research application fields in which lung slices proved to be a very efficient alternative to animal experimentation for biomechanical, physiological, pharmacological and toxicological approaches. 2.Focus is made on air-liquid interface dynamic organ culture systems that allow direct tissue exposure to complex aerosol and that best mimic in vivo lung tissue physiology. 3.A compilation of research applications in the fields of vascular and airway reactivity, mucociliary transport, polyamine transport, xenobiotic biotransformation, chemicals toxicology and complex aerosols supports the concept that precision cut lung slices are a very efficient tool maintaining highly differentiated functions similar to in vivo lung organ when kept under dynamic organ culture. They also have been successfully used for lung gene transfer efficiency assessment, for lung viral infection efficiency assessment, for studies of tissue preservation media and tissue post-conditioning to optimize lung tissue viability before grafting. 4.Taken all together, the reviewed studies point to a great interest for precision cut lung slices as an efficient and valuable alternative to in vivo lung organ experimentation.

  6. Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yu-Min; Sun, Ai-Min; Wang, Qian; Zhu, Ming; Qiu, Hai-Sheng [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Radiology, Shanghai (China); Jaffe, Richard B. [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States); Liu, Jin-Fen [Shanghai Children' s Medical Center, Department of Cardiothoracic Surgery, Shanghai (China); Gao, Wei [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Cardiology, Shanghai (China); Berdon, Walter E. [Children' s Hospital of New York, Department of Radiology, New York, NY (United States)

    2014-07-15

    Absent pulmonary valve is a rare cardiovascular anomaly that can result in profound tracheobronchial compression. To demonstrate the advantage of multi-slice CT in diagnosing tracheobronchial compression, its severity as related to the adjacent dilated pulmonary arteries, and associated lung and cardiac lesions. We included children with absent pulmonary valve who were reviewed by multi-slice CT during a 17-year period. The number and locations of stenoses and lung lesions were noted and the severity of stenosis was categorized. The diameter of the pulmonary artery was measured and associated cardiac defects were demonstrated. Thirty-one children (14 girls and 17 boys) were included. Of these, 29 had ventricular septal defect and 2 had an intact ventricular septum. Twenty-nine children (94%) had tracheobronchial compression, judged to be mild in nine children (31%), moderate in 10 (34%) and severe in 10 (34%). The different locations of the stenosis (carina, main bronchi, lobar and segmental bronchi) were observed. And the number and location of lung lesions demonstrated that the right middle and left upper and lower lobes were often affected. The diameter of the pulmonary artery in these children was well above normal published values, and Spearman rank correlation analysis showed a correlation between the size of the pulmonary artery and the severity of the tracheobronchial stenosis. Nineteen children (61%) underwent surgery and 4 of these children had a multi-slice CT post-operative follow-up study. Absent pulmonary valve can cause significant morbidity and mortality in children. Multi-slice CT can accurately depict areas of tracheobronchial compression, associated lung lesions and cardiac defects, helping to direct the surgeon. (orig.)

  7. Microfluidic culture chamber for the long-term perfusion and precise chemical stimulation of organotypic brain tissue slices

    DEFF Research Database (Denmark)

    Caicedo, H. H.; Vignes, M.; Brugg, B.

    2010-01-01

    We have developed a microfluidic perfusion-based culture system to study long-term in-vitro responses of organo-typic brain slices exposed to localized neurochemical stimulation. Using this microperfusion chamber we show that hip-pocampal organotypic brain slices cultures grown on nitrocellulose ...

  8. Using a high-speed movie camera to evaluate slice dropping in clinical image interpretation with stack mode viewers.

    OpenAIRE

    Yakami, Masahiro; Yamamoto, Akira; Yanagisawa, Morio; Sekiguchi, Hiroyuki; Kubo, Takeshi; Togashi, Kaori

    2013-01-01

    The purpose of this study is to verify objectively the rate of slice omission during paging on picture archiving and communication system (PACS) viewers by recording the images shown on the computer displays of these viewers with a high-speed movie camera. This study was approved by the institutional review board. A sequential number from 1 to 250 was superimposed on each slice of a series of clinical Digital Imaging and Communication in Medicine (DICOM) data. The slices were displayed using ...

  9. A modular method to handle multiple time-dependent quantities in Monte Carlo simulations

    International Nuclear Information System (INIS)

    Shin, J; Faddegon, B A; Perl, J; Schümann, J; Paganetti, H

    2012-01-01

    A general method for handling time-dependent quantities in Monte Carlo simulations was developed to make such simulations more accessible to the medical community for a wide range of applications in radiotherapy, including fluence and dose calculation. To describe time-dependent changes in the most general way, we developed a grammar of functions that we call ‘Time Features’. When a simulation quantity, such as the position of a geometrical object, an angle, a magnetic field, a current, etc, takes its value from a Time Feature, that quantity varies over time. The operation of time-dependent simulation was separated into distinct parts: the Sequence samples time values either sequentially at equal increments or randomly from a uniform distribution (allowing quantities to vary continuously in time), and then each time-dependent quantity is calculated according to its Time Feature. Due to this modular structure, time-dependent simulations, even in the presence of multiple time-dependent quantities, can be efficiently performed in a single simulation with any given time resolution. This approach has been implemented in TOPAS (TOol for PArticle Simulation), designed to make Monte Carlo simulations with Geant4 more accessible to both clinical and research physicists. To demonstrate the method, three clinical situations were simulated: a variable water column used to verify constancy of the Bragg peak of the Crocker Lab eye treatment facility of the University of California, the double-scattering treatment mode of the passive beam scattering system at Massachusetts General Hospital (MGH), where a spinning range modulator wheel accompanied by beam current modulation produces a spread-out Bragg peak, and the scanning mode at MGH, where time-dependent pulse shape, energy distribution and magnetic fields control Bragg peak positions. Results confirm the clinical applicability of the method. (paper)

  10. Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure.

    Science.gov (United States)

    Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John

    2011-06-01

    The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  11. RF photo-injector beam energy distribution studies by slicing technique

    Science.gov (United States)

    Filippetto, D.; Bellaveglia, M.; Musumeci, P.; Ronsivalle, C.

    2009-07-01

    The SPARC photo-injector is an R&D facility dedicated to the production of high brightness electron beams for radiation generation via FEL or Thomson scattering processes. It is the prototype injector for the recently approved SPARX project, aiming at the construction in the Frascati/University of Rome Tor Vergata area of a new high brightness electron linac for the generation of SASE-FEL radiation in the 1-10 nm wavelength range. The first phase of the SPARC project has been dedicated to the e-beam source characterization; the beam transverse and longitudinal parameters at the exit of the gun have been measured, and the photo-injector settings optimized to achieve best performance. Several beam dynamics topics have been experimentally studied in this first phase of operation, as, for example, the effect of photocathode driver laser beam shaping and the evolution of the beam transverse emittance. These studies have been made possible by the use of a novel diagnostic tool, the " emittance-meter" which enables the measurement of the transverse beam parameters at different positions along the propagation axis in the very interesting region at the exit of the RF gun. The new idea of extending the e-meter capabilities came out more recently. Information on the beam longitudinal phase space and correlations with the transverse planes can be retrieved by the slicing technique. In this paper, we illustrate the basic concept of the measurement together with simulations that theoretically validate the methodology. Some preliminary results are discussed and explained with the aid of code simulations.

  12. Progress towards 3D black hole merger simulations

    International Nuclear Information System (INIS)

    Seidel, E.

    2001-01-01

    I review recent progress in 3D numerical relativity, focused on simulations involving black holes evolved with singularity avoiding slicings, but also touching on recent results in advanced techniques like black hole excision. After a long series of axisymmetric and perturbative studies of distorted black holes and black hole collisions, similar studies were carried out with full 3D codes. The results showed that such black hole simulations can be carried out extremely accurately, although instabilities plague the simulation at uncomfortably early times. However, new formulations of Einstein's equations allow much more stable 3D evolutions than ever before, enabling the first studies of 3D gravitational collapse to a black hole. With these new formulations, for example, it has been possible to perform the first detailed simulations of 3D grazing collisions of black holes with unequal mass, spin, and with orbital angular momentum. I discuss the 3D black hole physics that can now be studied, and prospects for the future, which look increasingly bright due to recent progress in formulations, black hole excision, new gauge conditions, and larger computers. Simulations may soon be able to provide information about the final plunge of two black holes, of relevance for gravitational wave astronomy. (author)

  13. Estimating order-picking times for return heuristic - equations and simulations

    Directory of Open Access Journals (Sweden)

    Grzegorz Tarczyński

    2015-09-01

    Full Text Available Background: A key element of the evaluation of warehouse operation is the average order-picking time. In warehouses where the order-picking process is carried out according to the "picker-to-part" rule the order-picking time is usually proportional to the distance covered by the picker while picking items. This distance can by estimated by simulations or using mathematical equations. In the paper only the best described in the literature one-block rectangular warehouses are considered. Material and methods: For the one-block rectangular warehouses there are well known five routing heuristics. In the paper the author considers the return heuristic in two variants. The paper presents well known Hall's and De Koster's equations for the average distance traveled by the picker while completing items from one pick list. The author presents own proposals for calculating the expected distance. Results: the results calculated by the use of mathematical equations (the formulas of Hall, De Koster and own propositions were compared with the average values obtained using computer simulations. For the most cases the average error does not exceed 1% (except for Hall's equations. To carry out simulation the computer software Warehouse Real-Time Simulator was used. Conclusions: the order-picking time is a function of many variables and its optimization is not easy. It can be done in two stages: firstly using mathematical equations the set of the potentially best variants is established, next the results are verified using simulations. The results calculated by the use of equations are not precise, but possible to achieve immediately. The simulations are more time-consuming, but allow to analyze the order-picking process more accurately.

  14. Multi-slice and dual-source CT in cardiac imaging. Principles - protocols - indications - outlook. 2. ed.

    International Nuclear Information System (INIS)

    Ohnesorge, B.M.; Flohr, T.G.; Becker, C.R.; Reiser, M.F.; Knez, A

    2007-01-01

    Cardiac diseases, and in particular coronary artery disease, are the leading cause of death and morbidity in industrialized countries. The development of non-invasive imaging techniques for the heart and the coronary arteries has been considered a key element in improving patient care. A breakthrough in cardiac imaging using CT occurred in 1998, with the introduction of multi-slice computed tomography (CT). Since then, amazing advances in performance have taken place with scanners that acquire up to 64 slices per rotation. This book discusses the state-of-the-art developments in multi-slice CT for cardiac imaging as well as those that can be anticipated in the future. It serves as a comprehensive work that covers all aspects of this technology, from the technical fundamentals and image evaluation all the way to clinical indications and protocol recommendations. This fully reworked second edition draws on the most recent clinical experience obtained with 16- and 64-slice CT scanners by world-leading experts from Europe and the United States. It also includes ''hands-on'' experience in the form of 10 representative clinical case studies, which are included on the accompanying CD. As a further highlight, the latest results of the very recently introduced dual-source CT, which may soon represent the CT technology of choice for cardiac applications, are presented. This book will not only convince the reader that multi-slice cardiac CT has arrived in clinical practice, it will also make a significant contribution to the education of radiologists, cardiologists, technologists, and physicists-whether newcomers, experienced users, or researchers. (orig.)

  15. PICTURE, 2-D Slices Through 3-D CG of MORSE, QAD-CG

    International Nuclear Information System (INIS)

    1994-01-01

    1 - Description of program or function: Picture generates plots of two-dimensional slices through the three-dimensional geometry described by the combinatorial geometry (CG) package used in such codes as MORSE and QAD-CG. These plots are printed on a standard line printer. 2 - Method of solution: Several different ways are available to obtain a two-dimensional slice through the geometry. The geometry ray tracing capability is tested by forcing the geometry package to execute the routines and logic of the Monte Carlo random walk or kernel integration algorithms. 3 - Restrictions on the complexity of the problem: None tested besides those listed in the input descriptions

  16. Effect of calcium chloride and calcium lactate on quality and shelf-life of fresh-cut guava slices

    International Nuclear Information System (INIS)

    Raheem, M.I.U.; Huma, N.; Anjum, F.M.

    2013-01-01

    Present study was conducted to investigate the effectiveness of chemical treatments at low temperature on the quality of fresh-cut guava slices during 2011-12. Uniform sized guava slices were made free from seeds and treated with calcium chloride and calcium lactate with concentration 0.9%, 1.8%, 2.7% or 3.6%. After packing in plastic boxes, all treated samples were stored at 5 degree C + 2 degree C in a refrigerator for 24 days with 6 day interval between different removals. The results obtained from physico-chemical analysis showed decrease in firmness (111.67-12.67gf) and increase in browning (1.19-1.93nm) of guava slices compared to control with the passage of storage interval. Moreover, scores in taste (7.33-1.00), flavour (7.33-1.00), colour (7.50-1.00) and texture (7.67-1.00) of guava slices was also decreased with respect to interaction of treatments and storage period. Calcium chloride at the rate 2.7% showed significantly higher stability than other concentrations of calcium chloride and calcium lactate in delaying firmness and browning of fresh-cut guava slices along with maintaining their organoleptic properties for longer storage period. However, calcium chloride imparted undesirable bitterness to fresh-cut guava slices at the concentration of 3.6%. Based on the overall quality performance, 2.7% calcium chloride and 3.6% calcium lactate exhibited better results than other concentrations and control with storage life of 8 days at 5 degree C + 2 degree C. (author)

  17. Characterization of masses in digital breast tomosynthesis: comparison of machine learning in projection views and reconstructed slices.

    Science.gov (United States)

    Chan, Heang-Ping; Wu, Yi-Ta; Sahiner, Berkman; Wei, Jun; Helvie, Mark A; Zhang, Yiheng; Moore, Richard H; Kopans, Daniel B; Hadjiiski, Lubomir; Way, Ted

    2010-07-01

    In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 degree arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered

  18. A COMPARATIVE STUDY OF TYMPANOPLASTY USING SLICED CARTILAGE GRAFT VS. TEMPORALIS FASCIA GRAFT

    Directory of Open Access Journals (Sweden)

    Rahul Ashok Telang

    2018-02-01

    Full Text Available BACKGROUND The objective of the study was to compare the hearing improvement after using sliced cartilage graft with that of temporalis fascia and to compare the graft take-up between the two graft materials. MATERIALS AND METHODS A prospective clinical study including 60 patients with chronic mucosal otitis media, who were selected randomly from the outpatient department, after obtaining their consent were divided into 2 groups of 30 each, and evaluated according the study protocol. Their pre-operative audiometry was recorded and both groups of patients underwent surgery with one of the graft materials- temporalis fascia or sliced tragal cartilage with a thickness of 0.5 mm. All patients were regularly followed up and post-operative audiometry was done at 3 months. The hearing improvement in the form of closure of air-bone-gap and graft take-up was analysed statistically. RESULTS The temporalis fascia graft group had a pre-operative ABG of 22.33 ± 6.24 dB and post-operative ABG of 12.33 ± 4.72 dB with hearing improvement of 10.00 dB. The sliced cartilage graft group had a pre-operative ABG of 20.77 ± 5.75 dB and postoperative ABG of 10.50 ± 4.46 dB with hearing improvement of 10.27 dB. In the temporalis fascia group, 28 (93.3% patients had good graft take-up and in the sliced cartilage group 29 (96.7% had good graft take-up. There was statistically significant hearing improvement in both of our study groups but there was no statistically significant difference between the two groups. There was no statistically significant difference in graft take-up also. CONCLUSION Sliced cartilage graft is a good auto-graft material in tympanoplasty, which can give good hearing improvement and has good graft take-up, which is comparable with that of temporalis fascia.

  19. The Simulation Realization of Pavement Roughness in the Time Domain

    Science.gov (United States)

    XU, H. L.; He, L.; An, D.

    2017-10-01

    As the needs for the dynamic study on the vehicle-pavement system and the simulated vibration table test, how to simulate the pavement roughness actually is important guarantee for whether calculation and test can reflect the actual situation or not. Using the power spectral density function, the simulation of pavement roughness can be realized by Fourier inverse transform. The main idea of this method was that the spectrum amplitude and random phase were obtained separately according to the power spectrum, and then the simulation of pavement roughness was obtained in the time domain through the Fourier inverse transform (IFFT). In the process, the sampling interval (Δl) was 0.1m, and the sampling points(N) was 4096, which satisfied the accuracy requirements. Using this method, the simulate results of pavement roughness (A~H grades) were obtain in the time domain.

  20. DRK methods for time-domain oscillator simulation

    NARCIS (Netherlands)

    Sevat, M.F.; Houben, S.H.M.J.; Maten, ter E.J.W.; Di Bucchianico, A.; Mattheij, R.M.M.; Peletier, M.A.

    2006-01-01

    This paper presents a new Runge-Kutta type integration method that is well-suited for time-domain simulation of oscillators. A unique property of the new method is that its damping characteristics can be controlled by a continuous parameter.

  1. Effects of Administration of Perinatal Bupropion on the Population Spike Amplitude in Neonatal Rat Hippocampal Slice

    Directory of Open Access Journals (Sweden)

    Soomaayeh Heysieat-talab

    2010-09-01

    Full Text Available Objective(sBupropion is an atypical antidepressant that is widely used in smoke cessation under FDA approval. The study of synaptic effects of bupropion can help to finding out its mechanism(s for stopping nicotine dependence. In this study the effects of perinatal bupropion on the population spike (PS amplitude of neonates were investigated. Materials and Methods Hippocampal slices were prepared from 18-25 days old rat pups. The experimental groups included control and bupropion-treated. Bupropion (40 mg/Kg, i.p. was applied daily in perinatal period as pre-treatment. Due to the studying acute effects, bupropion was also added to the perfusion medium (10, 50, 200 μM for 30 min. The evoked PS was recorded from pyramidal layer of CA1 area, following stimulation of Schaffer collaterals. ResultsA concentration of 10 μM bupropion had no significant effects on the PS amplitude. The 50 μM concentration of bupropion reduced the amplitude of responses in 50% of the studied cases. At a concentration of 200 μM, the recorded PS amplitudes were reduced in all slices (n= 22. Amplitude was completely abolished in 8 out of the 22 slices. The decrease of the PS amplitude was found to be more in the non-pre-treated slices than in the pre-treated slices when both were perfused with 200 μM bupropion.Conclusion The results showed the perinatal exposure to bupropion and its acute effects while indicating that at concentrations of 50 and 200 μM bupropion reduced the PS amplitude. It was also found that there was evidence of synaptic adaptation in comparison of bupropion-treated and non-treated slices whereas they were both perfused with 200 µM.

  2. Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses.

    NARCIS (Netherlands)

    Scheenen, T.W.J.; Heerschap, A.; Klomp, D.W.J.

    2008-01-01

    OBJECTIVE: To explore the possibilities of proton spectroscopic imaging (1H-MRSI) of the human brain at 7 Tesla with adiabatic refocusing pulses. MATERIALS AND METHODS: A combination of conventional slice selective excitation and two pairs of slice selective adiabatic refocusing pulses (semi-LASER)

  3. Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography

    Science.gov (United States)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...

  4. Gravitational clustering of galaxies in the CfA slice

    International Nuclear Information System (INIS)

    Crane, P.; Saslaw, W.C.

    1988-01-01

    The clustering properties of the Galaxies in the CfA slice have been analyzed by comparing the properties of the neighbor distributions to the predictions of gravitational clustering theory. The agreement is excellent and implies that the observed structures can be explained by gravitational effects alone and do not require exotic explanations

  5. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    International Nuclear Information System (INIS)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M.; Welte, T.; Kropf, S.

    2000-01-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  6. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    Energy Technology Data Exchange (ETDEWEB)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M. [Department of Diagnostic Radiology, Otto-von-Guericke University, Magdeburg (Germany); Welte, T. [Department of Cardiology, Angiology, and Pneumology, Otto-von-Guericke University, Magdeburg (Germany); Kropf, S. [Department of Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg (Germany)

    2000-06-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  7. Nonlinear time-dependent simulation of helix traveling wave tubes

    International Nuclear Information System (INIS)

    Peng Wei-Feng; Yang Zhong-Hai; Hu Yu-Lu; Li Jian-Qing; Lu Qi-Ru; Li Bin

    2011-01-01

    A one-dimensional nonlinear time-dependent theory for helix traveling wave tubes is studied. A generalized electromagnetic field is applied to the expression of the radio frequency field. To simulate the variations of the high frequency structure, such as the pitch taper and the effect of harmonics, the spatial average over a wavelength is substituted by a time average over a wave period in the equation of the radio frequency field. Under this assumption, the space charge field of the electron beam can be treated by a space charge wave model along with the space charge coefficient. The effects of the radio frequency and the space charge fields on the electrons are presented by the equations of the electron energy and the electron phase. The time-dependent simulation is compared with the frequency-domain simulation for a helix TWT, which validates the availability of this theory. (interdisciplinary physics and related areas of science and technology)

  8. Time-Dependent Simulation of Free-Electron Laser Amplifiers and Oscillators

    CERN Document Server

    Freund, H

    2005-01-01

    Time-dependent FEL simulations use a variety of techniques. Most simulations use a slowly varying envelope approximation (SVEA). One such technique assumes that the envelope varies only in z combined with a field representation as an ensemble of discrete harmonics, which is equivalent to a time-dependent simulation [1] but is computationally prohibitive. A second technique uses an SVEA in both in z and t [2]. The particles and fields are advanced in z using the same process as in steady-state simulations and then the time derivative describing slippage is applied. This is used in wiggler-averaged codes such as GINGER [3] and GENESIS [4]. We describe the inclusion of this technique in the non-wiggler-averaged code MEDUSA [5], which is applied to amplifiers and oscillators. MEDUSA differs from GINGER and GENESIS also in the way the field is treated. GINGER and GENESIS use a field solver and must explicitly propagate the field outside the wiggler oscillators. This is computationally intensive. MEDUSA uses a Gaus...

  9. Real time hardware-in-loop simulation of ESMO satellite attitude control system

    Directory of Open Access Journals (Sweden)

    Rune Finnset

    2006-04-01

    Full Text Available This paper studies attitude control of the ESMO satellite using six reaction thrusters. Bang-bang control with dead-zone and Pulse-Width Modulation (PWM for the modulation of the on-time of the thrusters are treated. Closed loop hardware-in-loop simulations, using themicrocontroller unit (MCU Microchip PIC18F452 for implementation of attitude control and MatLab in a standard PC for simulating satellite dynamics, are carried out. Results for real time simulation are compared with autonomous simulations. The controller gives a satisfactory performance in the real time environment.

  10. A Comparative Study of Spiral Tomograms with Different Slice Thicknesses in Dental Implant Planning

    International Nuclear Information System (INIS)

    Yoon Sook Ja

    1999-01-01

    To know whether there would be a difference among spiral tomograms of different slice thicknesses in the measurement of distances which are used for dental implant planning. 10 dry mandibules and 40 metal balls are used to take total 120 Scanora tomograms with the slice thickness of 2 mm, 4 mm and 8 mm. 3 oral radiologists interpreted each tomogram to measure the distances from the mandibular canal to the alveoalr crest and buccal, lingual and inferior borders of mandible. 3 observers recorded grades of 0, 1 or 2 to evaluate the perceptibility of alveolar crest and the superior border of mandibular canal. For statistical analysis, ANOVA with repeated measure, Chi-square tests and intraclass correlation coefficient (R2, alpha) were used. There was not a statistically significant difference among spiral tomograms with different slice thicknesses in the measurement of the distances and in the perceptibility of alveolar crest and mandibular canal (p>0.05). All of them showed a good relationship in the reliability analysis. The perceptibility of alveolar crest and mandibular canal was almost similar and an excellent relationship was seen on all of them. There would be no significant difference, no matter which spiral tomogram of any slice thickness may be used in dental implant planning, considering the thickness of dental implant fixture.

  11. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  12. Extending molecular simulation time scales: Parallel in time integrations for high-level quantum chemistry and complex force representations

    International Nuclear Information System (INIS)

    Bylaska, Eric J.; Weare, Jonathan Q.; Weare, John H.

    2013-01-01

    Parallel in time simulation algorithms are presented and applied to conventional molecular dynamics (MD) and ab initio molecular dynamics (AIMD) models of realistic complexity. Assuming that a forward time integrator, f (e.g., Verlet algorithm), is available to propagate the system from time t i (trajectory positions and velocities x i = (r i , v i )) to time t i+1 (x i+1 ) by x i+1 = f i (x i ), the dynamics problem spanning an interval from t 0 …t M can be transformed into a root finding problem, F(X) = [x i − f(x (i−1 )] i =1,M = 0, for the trajectory variables. The root finding problem is solved using a variety of root finding techniques, including quasi-Newton and preconditioned quasi-Newton schemes that are all unconditionally convergent. The algorithms are parallelized by assigning a processor to each time-step entry in the columns of F(X). The relation of this approach to other recently proposed parallel in time methods is discussed, and the effectiveness of various approaches to solving the root finding problem is tested. We demonstrate that more efficient dynamical models based on simplified interactions or coarsening time-steps provide preconditioners for the root finding problem. However, for MD and AIMD simulations, such preconditioners are not required to obtain reasonable convergence and their cost must be considered in the performance of the algorithm. The parallel in time algorithms developed are tested by applying them to MD and AIMD simulations of size and complexity similar to those encountered in present day applications. These include a 1000 Si atom MD simulation using Stillinger-Weber potentials, and a HCl + 4H 2 O AIMD simulation at the MP2 level. The maximum speedup ((serial execution time)/(parallel execution time) ) obtained by parallelizing the Stillinger-Weber MD simulation was nearly 3.0. For the AIMD MP2 simulations, the algorithms achieved speedups of up to 14.3. The parallel in time algorithms can be implemented in a

  13. Multi-scale simulations of droplets in generic time-dependent flows

    Science.gov (United States)

    Milan, Felix; Biferale, Luca; Sbragaglia, Mauro; Toschi, Federico

    2017-11-01

    We study the deformation and dynamics of droplets in time-dependent flows using a diffuse interface model for two immiscible fluids. The numerical simulations are at first benchmarked against analytical results of steady droplet deformation, and further extended to the more interesting case of time-dependent flows. The results of these time-dependent numerical simulations are compared against analytical models available in the literature, which assume the droplet shape to be an ellipsoid at all times, with time-dependent major and minor axis. In particular we investigate the time-dependent deformation of a confined droplet in an oscillating Couette flow for the entire capillary range until droplet break-up. In this way these multi component simulations prove to be a useful tool to establish from ``first principles'' the dynamics of droplets in complex flows involving multiple scales. European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie Grant Agreement No 642069. & European Research Council under the European Community's Seventh Framework Program, ERC Grant Agreement No 339032.

  14. Ethanol induces MAP2 changes in organotypic hippocampal slice cultures

    DEFF Research Database (Denmark)

    Noraberg, J; Zimmer, J

    1998-01-01

    loss of CA3 pyramidal cells and moderate loss of dentate granule cells, as seen in vivo. The results indicate that brain slice cultures combined with immunostaining for cytoskeleton and neuronal markers can be used for studies of ethanol and organic solvent neurotoxicity.......Microtubule-associated protein 2 (MAP2) and neuron-specific protein (NeuN) immunostains were used to demonstrate neurotoxic effects in mature hippocampal slice cultures exposed to ethanol (50, 100, 200 mM) for 4 weeks. At the low dose the density of MAP2 immunostaining in the dentate molecular...... layer was 118% of the control cultures, with no detectable changes in CA1 and CA3. At 100 mM no changes were detected, while 200 mM ethanol significantly reduced the MAP2 density in both dentate (19%) and hippocampal dendritic fields (CA3, 52%; CA1, 55%). At this dose NeuN staining showed considerable...

  15. The effect of ultraviolet treatment on enzymatic activity and total phenolic content of minimally processed potato slices.

    Science.gov (United States)

    Teoh, Li Shing; Lasekan, Ola; Adzahan, Noranizan Mohd; Hashim, Norhashila

    2016-07-01

    In this work, potato slices were exposed to different doses of UV-C irradiation (i.e. 2.28, 6.84, 11.41, and 13.68 kJ m -2 ) with or without pretreatment [i.e. ascorbic acid and calcium chloride (AACCl) dip] and stored at 4 ± 1 °C. Changes in enzymatic activities of polyphenol oxidase (PPO), peroxidase (POD) and phenylalanine ammonia lyase (PAL), as well as total phenolic content (TPC) were investigated after 0, 3, 7 and 10 days of storage. Results showed that untreated and UV-C treated potato slices at 13.68 kJ m -2 dosage level showed significantly higher PPO, POD and PAL activities. Conversely, untreated potato slices showed the lowest TPC during storage period. Potato slices subjected to AACCl dip plus UV-C at 6.84 kJ m -2 produced lower PPO, POD and PAL activities, as well as maintained a high TPC during storage.

  16. Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla.

    Science.gov (United States)

    Edelman, Robert R; Giri, S; Pursnani, A; Botelho, M P F; Li, W; Koktzoglou, I

    2015-11-23

    Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enhanced, quiescent-interval slice-selective (QISS) 2D technique. Sequence performance was compared at 1.5 and 3 Tesla using both radial and Cartesian k-space trajectories. The left coronary circulation was imaged in six healthy subjects and two patients with coronary artery disease. Breath-hold QISS was compared with T2-prepared 2D balanced steady-state free-precession (bSSFP) and free-breathing, navigator-gated 3D bSSFP. Approximately 10 2.1-mm thick slices were acquired in a single ~20-s breath-hold using two-shot QISS. QISS contrast-to-noise ratio (CNR) was 1.5-fold higher at 3 Tesla than at 1.5 Tesla. Cartesian QISS provided the best coronary-to-myocardium CNR, whereas radial QISS provided the sharpest coronary images. QISS image quality exceeded that of free-breathing 3D coronary MRA with few artifacts at either field strength. Compared with T2-prepared 2D bSSFP, multi-slice capability was not restricted by the specific absorption rate at 3 Tesla and pericardial fluid signal was better suppressed. In addition to depicting the coronary arteries, QISS could image intra-cardiac structures, pericardium, and the aortic root in arbitrary slice orientations. Breath-hold QISS is a simple, versatile, and time-efficient method for coronary MRA that provides excellent image quality at both 1.5 and 3 Tesla. Image quality exceeded that of free-breathing, navigator-gated 3D MRA in a much shorter scan time. QISS also allowed rapid multi-slice bright-blood, diastolic phase imaging of the heart, which may have complementary value to multi-phase cine imaging. We conclude that, with further clinical

  17. Variations in Atlantic surface ocean paleoceanography, 50°-80° N: A time-slice record of the last 30,000 years

    Science.gov (United States)

    Sarnthein, Michael; Jansen, Eystein; Weinelt, Mara; Arnold, Maurice; Duplessy, Jean Claude; Erlenkeuser, Helmut; FlatøY, Astrid; Johannessen, Gro; Johannessen, Truls; Jung, Simon; Koc, Nalan; Labeyrie, Laurent; Maslin, Mark; Pflaumann, Uwe; Schulz, Hartmut

    1995-12-01

    Eight time slices of surface-water paleoceanography were reconstructed from stable isotope and paleotemperature data to evaluate late Quaternary changes in density, current directions, and sea-ice cover in the Nordic Seas and NE Atlantic. We used isotopic records from 110 deep-sea cores, 20 of which are accelerator mass spectrometry (AMS)-14C dated and 30 of which have high (>8 cm /kyr) sedimentation rates, enabling a resolution of about 120 years. Paleotemperature estimates are based on species counts of planktonic foraminifera in 18 cores. The δ18O and δ13C distributions depict three main modes of surface circulation: (1) The Holocene-style interglacial mode which largely persisted over the last 12.8 14C ka, and probably during large parts of stage 3. (2) The peak glacial mode showing a cyclonic gyre in the, at least, seasonally ice-free Nordic Seas and a meltwater lens west of Ireland. Based on geostrophic forcing, it possibly turned clockwise, blocked the S-N flow across the eastern Iceland-Shetland ridge, and enhanced the Irminger current around west Iceland. It remains unclear whether surface-water density was sufficient for deepwater formation west of Norway. (3) A meltwater regime culminating during early glacial Termination I, when a great meltwater lens off northern Norway probably induced a clockwise circulation reaching south up to Faeroe, the northward inflow of Irminger Current water dominated the Icelandic Sea, and deepwater convection was stopped. In contrast to circulation modes two and three, the Holocene-style circulation mode appears most stable, even unaffected by major meltwater pools originating from the Scandinavian ice sheet, such as during δ18O event 3.1 and the Bölling. Meltwater phases markedly influenced the European continental climate by suppressing the "heat pump" of the Atlantic salinity conveyor belt. During the peak glacial, melting icebergs blocked the eastward advection of warm surface water toward Great Britain, thus

  18. Physical time scale in kinetic Monte Carlo simulations of continuous-time Markov chains.

    Science.gov (United States)

    Serebrinsky, Santiago A

    2011-03-01

    We rigorously establish a physical time scale for a general class of kinetic Monte Carlo algorithms for the simulation of continuous-time Markov chains. This class of algorithms encompasses rejection-free (or BKL) and rejection (or "standard") algorithms. For rejection algorithms, it was formerly considered that the availability of a physical time scale (instead of Monte Carlo steps) was empirical, at best. Use of Monte Carlo steps as a time unit now becomes completely unnecessary.

  19. The accuracy of ventricular volume measurement and the optimal slice thickness by using multislice helical computed tomography

    International Nuclear Information System (INIS)

    Cui Wei; Guo Yuyin

    2005-01-01

    Objective: To determine the optimal slice thickness for ventricular volume measurement by tomographic multislice Simpson's method and to evaluate the accuracy of ventricular volume measured by multislice helical computed tomography (MSCT) in human ventricular casts. Methods: Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned with MSCT scanner by using a scanning protocol similar to clinical practice. A series of LV and RV short-axis images were reconstructed with slice thickness of 2 mm, 3.5 mm, 5 mm, 7 mm, and 10 mm, respectively. Multislice Simpson's method was used to calculate LV and RV volumes and true cast volume was determined by water displacement. Results: The true LV and RV volumes were (55.57 ± 28.91) ml, and (64.23 ± 24.51) ml, respectively. The calculated volumes from different slice thickness ranged from (58.78 ± 28.93) ml to (68.15 ± 32.57) ml for LV casts, and (74.45 ± 27.81) ml to (88.14 ± 32.91) ml for RV casts, respectively. Both the calculated LV and RV volumes correlated closely with the corresponding true volumes (all r > 0.95, P<0.001), but overestimated the corresponding true volume by (3.21 ± 5.95) to (12.58 ± 8.56) ml for LV and (10.22 ± 8.45) to (23.91 ± 12.24) ml for RV (all P<0.01). There was a close correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.001). However, when slice thickness was reduced to 5.0 mm, the overestimation became nonsignificant for slice thickness through 2.0 mm to 5.0 mm, and also for both LV and RV volume measurements. Conclusion: Both LV and RV volumes can be accurately calculated with MSCT. A 5 mm slice thickness is enough and most efficient for accurate measurement of LV and RV volume. (authors)

  20. Effects of chemical composite, puffing temperature and intermediate moisture content on physical properties of potato and apple slices

    Science.gov (United States)

    Tabtaing, S.; Paengkanya, S.; Tanthong, P.

    2017-09-01

    Puffing technique is the process that can improve texture and volumetric of crisp fruit and vegetable. However, the effect of chemical composite in foods on puffing characteristics is still lack of study. Therefore, potato and apple slices were comparative study on their physical properties. Potato and apple were sliced into 2.5 mm thickness and 2.5 cm in diameter. Potato slices were treated by hot water for 2 min while apple slices were not treatment. After that, they were dried in 3 steps. First step, they were dried by hot air at temperature of 90°C until their moisture content reached to 30, 40, and 50 % dry basis. Then they were puffed by hot air at temperature of 130, 150, and 170°C for 2 min. Finally, they were dried again by hot air at temperature of 90°C until their final moisture content reached to 4% dry basis. The experimental results showed that chemical composite of food affected on physical properties of puffed product. Puffed potato had higher volume ratio than those puffed apple because potato slices contains starch. The higher starch content provided more hard texture of potato than those apples. Puffing temperature and moisture content strongly affected on the color, volume ratio, and textural properties of puffed potato slices. In addition, the high drying rate of puffed product observed at high puffing temperature and higher moisture content.

  1. Atomistic simulations of graphite etching at realistic time scales.

    Science.gov (United States)

    Aussems, D U B; Bal, K M; Morgan, T W; van de Sanden, M C M; Neyts, E C

    2017-10-01

    Hydrogen-graphite interactions are relevant to a wide variety of applications, ranging from astrophysics to fusion devices and nano-electronics. In order to shed light on these interactions, atomistic simulation using Molecular Dynamics (MD) has been shown to be an invaluable tool. It suffers, however, from severe time-scale limitations. In this work we apply the recently developed Collective Variable-Driven Hyperdynamics (CVHD) method to hydrogen etching of graphite for varying inter-impact times up to a realistic value of 1 ms, which corresponds to a flux of ∼10 20 m -2 s -1 . The results show that the erosion yield, hydrogen surface coverage and species distribution are significantly affected by the time between impacts. This can be explained by the higher probability of C-C bond breaking due to the prolonged exposure to thermal stress and the subsequent transition from ion- to thermal-induced etching. This latter regime of thermal-induced etching - chemical erosion - is here accessed for the first time using atomistic simulations. In conclusion, this study demonstrates that accounting for long time-scales significantly affects ion bombardment simulations and should not be neglected in a wide range of conditions, in contrast to what is typically assumed.

  2. Extending molecular simulation time scales: Parallel in time integrations for high-level quantum chemistry and complex force representations.

    Science.gov (United States)

    Bylaska, Eric J; Weare, Jonathan Q; Weare, John H

    2013-08-21

    Parallel in time simulation algorithms are presented and applied to conventional molecular dynamics (MD) and ab initio molecular dynamics (AIMD) models of realistic complexity. Assuming that a forward time integrator, f (e.g., Verlet algorithm), is available to propagate the system from time ti (trajectory positions and velocities xi = (ri, vi)) to time ti + 1 (xi + 1) by xi + 1 = fi(xi), the dynamics problem spanning an interval from t0[ellipsis (horizontal)]tM can be transformed into a root finding problem, F(X) = [xi - f(x(i - 1)]i = 1, M = 0, for the trajectory variables. The root finding problem is solved using a variety of root finding techniques, including quasi-Newton and preconditioned quasi-Newton schemes that are all unconditionally convergent. The algorithms are parallelized by assigning a processor to each time-step entry in the columns of F(X). The relation of this approach to other recently proposed parallel in time methods is discussed, and the effectiveness of various approaches to solving the root finding problem is tested. We demonstrate that more efficient dynamical models based on simplified interactions or coarsening time-steps provide preconditioners for the root finding problem. However, for MD and AIMD simulations, such preconditioners are not required to obtain reasonable convergence and their cost must be considered in the performance of the algorithm. The parallel in time algorithms developed are tested by applying them to MD and AIMD simulations of size and complexity similar to those encountered in present day applications. These include a 1000 Si atom MD simulation using Stillinger-Weber potentials, and a HCl + 4H2O AIMD simulation at the MP2 level. The maximum speedup (serial execution/timeparallel execution time) obtained by parallelizing the Stillinger-Weber MD simulation was nearly 3.0. For the AIMD MP2 simulations, the algorithms achieved speedups of up to 14.3. The parallel in time algorithms can be implemented in a

  3. Real-time numerical simulation of the Carnot cycle

    International Nuclear Information System (INIS)

    Hurkala, J; Gall, M; Kutner, R; Maciejczyk, M

    2005-01-01

    We developed a highly interactive, multi-windows Java applet which made it possible to simulate and visualize within any platform and internet the Carnot cycle (or engine) in a real-time computer experiment. We extended our previous model and algorithm (Galant et al 2003 Heat Transfer, Newton's Law of Cooling and the Law of Entropy Increase Simulated by the Real-Time Computer Experiments in Java (Lecture Notes in Computer Science vol 2657) pp 45-53, Gall and Kutner 2005 Molecular mechanisms of heat transfer: Debye relaxation versus power-law Physica A 352 347-78) to simulate not only the heat flow but also the macroscopic movement of the piston. Since in reality it is impossible to construct a reversible Carnot engine, the question arises whether it is possible to simulate it at least in a numerical experiment? The positive answer to this question which we found is related to our model and algorithm which make it possible to omit the many-body problem arising when many gas particles simultaneously interact with the mobile piston. As usual, the considerations of phenomenological thermodynamics began with a study of the basic properties of heat engines, hence our approach, besides intrinsic physical significance, is also important from the educational, technological and even environmental points of view

  4. Influence of 60Co γ irradiation pre-treatment on characteristics of hot air drying sweet potato slices

    International Nuclear Information System (INIS)

    Jiang Ning; Liu Chunquan; Li Dajing; Liu Xia; Yan Qimei

    2012-01-01

    The influences of irradiation, hot air temperature and thicknesses of the slices on the characters of dehydration and surface temperature of 60 Co γ-rays irradiated sweet potato were investigated. Meanwhile, microscopic observation and determination of water activity of irradiated sweet potato were conducted. The results show that the drying rate and the surface temperature rose with the increasing of irradiation dose. When the dry basis moisture content was 150%, the drying rate of the samples were 1.92, 1.97, 2.05, 2.28, 3.12% /min while the irradiation dose were 0, 2, 5, 8, 10 kGy, and the surface temperature were 48.5 ℃, 46.3℃, 44.5 ℃, 42.2 ℃, 41.5 ℃, respectively. With higher air temperature and thinner of the sweet potato slices, the dehydration of the irradiated sweet potato slices were faster. The drying speed of sweet potato slices at 85 ℃ was 170 min faster than that of 65 ℃. The drying speed of 7 mm sweet potato slices was 228 min faster than that of 3 mm sample. The cell wall and the vacuole of the sweet potato slices were broken after irradiation, and its water activity increased with the increase is radiation dose. The water activity of the irradiated samples were 0.92, 0.945, 0.958, 0.969, 0.979 with the irradiation doses of 0, 2, 5, 8, 10 kGy, respectively. The hot air drying rate, surface temperature and water activity of sweet potato are significantly impacted by irradiation. The conclusion provides a theoretical foundation for further processing technology of combined radiation and hot air drying sweet potato. (authors)

  5. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    International Nuclear Information System (INIS)

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman; Raupach, Rainer; Flohr, Thomas; Sommer, Torsten

    2006-01-01

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% ±10%) and more realistic lumen attenuation (222 HU ±66 HU) at the expense of increased noise (15.3 HU ±3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  6. Simulation of time-dependent free-surface Navier-Stokes flows

    International Nuclear Information System (INIS)

    Muldowney, G.P.

    1989-01-01

    Two numerical methods for simulation of time-dependent free-surface Navier-Stokes flows are developed. Both techniques are based on semi-implicit time advancement of the momentum equations, integral formulation of the spatial problem at each timestep, and spectral-element discretization to solve the resulting integral equation. Central to each algorithm is a boundary-specific solution step which permits the spatial treatment in two dimensions to be performed in O(N 3 ) operations per timestep despite the presence of deforming geometry. The first approach is a domain-integral formulation involving integrals over the entire flow domain of kernel functions which arise in time-differencing the Navier-Stokes equations. The second is a particular-solution formulation which replaces domain integration with an iterative scheme to generate particular velocity and pressure fields on individual elements, followed by a patching step to produce a particular solution continuous over the full domain. Two of the most difficult aspects of viscous free-surface flow simulations, namely time-dependent geometry and nontrivial boundary conditions, are well accommodated by these integral equation techniques. In addition the methods offer spectral accuracy in space and admit arbitrarily high-order discretization in time. For large-scale computations and/or long-term time advancement the domain-integral algorithm must be executed on a supercomputer to deliver results in reasonable processing time. A detailed simulation of gas liquid flow with full resolution of the free phase boundary requires approximately five CPU hours at 80 megaflops

  7. Organotypic hippocampal slice culture from the adult mouse brain: a versatile tool for translational neuropsychopharmacology.

    Science.gov (United States)

    Kim, Hyunjeong; Kim, Eosu; Park, Minsun; Lee, Eun; Namkoong, Kee

    2013-03-05

    One of the most significant barriers towards translational neuropsychiatry would be an unavailability of living brain tissues. Although organotypic brain tissue culture could be a useful alternative enabling observation of temporal changes induced by various drugs in living brain tissues, a proper method to establish a stable organotypic brain slice culture system using adult (rather than neonatal) hippocampus has been still elusive. In this study, we evaluated our simple method using the serum-free culture medium for successful adult organotypic hippocampal slice culture. Several tens of hippocampal slices from a single adult mouse (3-5 months old) were cultured in serum-free versus serum-containing conventional culture medium for 30 days and underwent various experiments to validate the effects of the existence of serum in the culture medium. Neither the excessive regression of neuronal viability nor metabolic deficiency was observed in the serum-free medium culture in contrast to the serum-containing medium culture. Despite such viability, newly generated immature neurons were scarcely detected in the serum-free culture, suggesting that the original neurons in the brain slice persist rather than being replaced by neurogenesis. Key structural features of in vivo neural tissue constituting astrocytes, neural processes, and pre- and post-synapses were also well preserved in the serum-free culture. In conclusion, using the serum-free culture medium, the adult hippocampal slice culture system will serve as a promising ex vivo tool for various fields of neuroscience, especially for studies on aging-related neuropsychiatric disorders or for high throughput screening of potential agents working against such disorders. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

    International Nuclear Information System (INIS)

    Chan, Heang-Ping; Wu Yita; Sahiner, Berkman; Wei, Jun; Helvie, Mark A.; Zhang Yiheng; Moore, Richard H.; Kopans, Daniel B.; Hadjiiski, Lubomir; Way, Ted

    2010-01-01

    Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 deg. arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19

  9. Slice simulation from a model of the parenchymous vascularization to evaluate texture features: work in progress.

    Science.gov (United States)

    Rolland, Y; Bézy-Wendling, J; Duvauferrier, R; Coatrieux, J L

    1999-03-01

    To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Parameters of statistical methods were measured on 16128x128 regions of interest, and mean values and standard deviation were calculated. For each parameter, the performances (discrimination power and stability) were evaluated. Among 11 calculated statistical parameters, three (homogeneity, entropy, mean of gradients) were found to have a good discriminating power to differentiate normal perfusion from hypervascularization, but only the gradient mean was found to have a good stability with respect to the thickness. Five parameters (run percentage, run length distribution, long run emphasis, contrast, and gray level distribution) were found to have intermediate results. In the remaining three, curtosis and correlation was found to have little discrimination power, skewness none. This 3D vascular model, which allows the generation of various examples of vascular textures, is a powerful tool to assess the performance of texture analysis methods. This improves our knowledge of the methods and should contribute to their a priori choice when designing clinical studies.

  10. IRAS galaxies and the large-scale structure in the CfA slice

    Science.gov (United States)

    Babul, Arif; Postman, Marc

    1990-01-01

    The spatial distributions of the IRAS and the optical galaxies in the first CfA slice are compared. The IRAS galaxies are generally less clustered than optical ones, but their distribution is essentially identical to that of late-type optical galaxies. The discrepancy between the clustering properties of the IRAS and optical samples in the CfA slice region is found to be entirely due to the paucity of IRAS galaxies in the core of the Coma cluster. The spatial distributions of the IRAS and the optical galaxies, both late and early types, outside the dense core of the Coma cluster are entirely consistent with each other. This conflicts with the prediction of the linear biasing scenario.

  11. Redshifts for fainter galaxies in the first CfA survey slice. II

    Science.gov (United States)

    Wegner, Gary; Thorstensen, John R.; Kurtz, Michael J.; Geller, Margaret J.; Huchra, John P.

    1990-01-01

    Redshifts were measured for 96 galaxies in right ascension alpha between 8h and 17h declination delta between 30 and 31 deg, and with m(Zwicky) in the range 15.6-15.7. These correspond to 94 of the 96 entries in the Zwicky-Nilson merged catalog. The declination range delta between 29 deg and 31 deg is now complete to m(Zwicky) = 15.7. The structures in the first 6-deg-wide slice of the Center for Astrophysics redshift survey slice (delta between 26.5 and 32.5 deg are clearly defined in the 2-deg-wide slightly deeper sample; the fainter galaxies trace the structures defined by the brighter ones.

  12. Real-time numerical simulation with high efficiency for an experimental reactor system

    International Nuclear Information System (INIS)

    Ding Shuling; Li Fu; Li Sifeng; Chu Xinyuan

    2006-01-01

    The paper presents a systematic and efficient method for numerical real-time simulation of an experimental reactor. The reactor models were built based on the physical characteristics of the experimental reactor, and several real-time simulation approaches were discussed and compared in the paper. How to implement the real-time reactor simulation system in Windows platform for the sake of hardware-in-loop experiment for the reactor power control system was discussed. (authors)

  13. Virtual reality myringotomy simulation with real-time deformation: development and validity testing.

    Science.gov (United States)

    Ho, Andrew K; Alsaffar, Hussain; Doyle, Philip C; Ladak, Hanif M; Agrawal, Sumit K

    2012-08-01

    Surgical simulation is becoming an increasingly common training tool in residency programs. The first objective was to implement real-time soft-tissue deformation and cutting into a virtual reality myringotomy simulator. The second objective was to test the various implemented incision algorithms to determine which most accurately represents the tympanic membrane during myringotomy. Descriptive and face-validity testing. A deformable tympanic membrane was developed, and three soft-tissue cutting algorithms were successfully implemented into the virtual reality myringotomy simulator. The algorithms included element removal, direction prediction, and Delaunay cutting. The simulator was stable and capable of running in real time on inexpensive hardware. A face-validity study was then carried out using a validated questionnaire given to eight otolaryngologists and four senior otolaryngology residents. Each participant was given an adaptation period on the simulator, was blinded to the algorithm being used, and was presented the three algorithms in a randomized order. A virtual reality myringotomy simulator with real-time soft-tissue deformation and cutting was successfully developed. The simulator was stable, ran in real time on inexpensive hardware, and incorporated haptic feedback and stereoscopic vision. The Delaunay cutting algorithm was found to be the most realistic algorithm representing the incision during myringotomy (P virtual reality myringotomy simulator is being developed and now integrates a real-time deformable tympanic membrane that appears to have face validity. Further development and validation studies are necessary before the simulator can be studied with respect to training efficacy and clinical impact. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  14. Implicit time-dependent finite different algorithm for quench simulation

    International Nuclear Information System (INIS)

    Koizumi, Norikiyo; Takahashi, Yoshikazu; Tsuji, Hiroshi

    1994-12-01

    A magnet in a fusion machine has many difficulties in its application because of requirement of a large operating current, high operating field and high breakdown voltage. A cable-in-conduit (CIC) conductor is the best candidate to overcome these difficulties. However, there remained uncertainty in a quench event in the cable-in-conduit conductor because of a difficulty to analyze a fluid dynamics equation. Several scientists, then, developed the numerical code for the quench simulation. However, most of them were based on an explicit time-dependent finite difference scheme. In this scheme, a discrete time increment is strictly restricted by CFL (Courant-Friedrichs-Lewy) condition. Therefore, long CPU time was consumed for the quench simulation. Authors, then, developed a new quench simulation code, POCHI1, which is based on an implicit time dependent scheme. In POCHI1, the fluid dynamics equation is linearlized according to a procedure applied by Beam and Warming and then, a tridiagonal system can be offered. Therefore, no iteration is necessary to solve the fluid dynamics equation. This leads great reduction of the CPU time. Also, POCHI1 can cope with non-linear boundary condition. In this study, comparison with experimental results was carried out. The normal zone propagation behavior was investigated in two samples of CIC conductors which had different hydraulic diameters. The measured and simulated normal zone propagation length showed relatively good agreement. However, the behavior of the normal voltage shows a little disagreement. These results indicate necessity to improve the treatment of the heat transfer coefficient in the turbulent flow region and the electric resistivity of the copper stabilizer in high temperature and high field region. (author)

  15. Triazolam-induced modulation of muscarinic acetylcholine receptor in living brain slices as revealed by a new positron-based imaging technique

    International Nuclear Information System (INIS)

    Murata, T.; Matsumura, K.; Onoe, H.; Watanabe, Y.; Sihver, S.; Sihver, W.; Langstroem, B.; Bergstroem, M.; Yonekura, Y.

    1997-01-01

    The effect of triazolam, a potent benzodiazepine (BZ) agonist, on muscarinic acetylcholinergic receptor (mAChR) binding was investigated in living brain slices by use of a novel positron-based imaging technique. Fresh rat brain slices were incubated with [ 11 C]N-methyl-4-piperidylbenzilate ([ 11 C]NMPB), a mAChR antagonist, in oxygenated Krebs-Ringer solution at 37 degree C. During incubation, time-resolved imaging of [ 11 C]NMPB binding in the slices was constructed on the storage phosphor screens. Addition of triazolam (1 μM) plus muscimol (30 μM), a GABA A receptor agonist, to the incubation mixture decreased the specific binding of [ 11 C]NMPB. Ro15-1788, a BZ receptor antagonist, prevented this effect, indicating that the effect was exerted through the GABA A /BZ receptor complex. These results demonstrated that stimulation of the GABA A /BZ receptor lowers the affinity of the mAChR for its ligand, which may underlie the BZ-induced amnesia, a serious clinical side effect of BZ. No such effect in the P2-fraction instead implies that the integrity of the neuronal cells and/or their environment is prerequisite for the modulation of mAChR by GABA A /BZ stimulation. (author)

  16. Extending molecular simulation time scales: Parallel in time integrations for high-level quantum chemistry and complex force representations

    Energy Technology Data Exchange (ETDEWEB)

    Bylaska, Eric J., E-mail: Eric.Bylaska@pnnl.gov [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352 (United States); Weare, Jonathan Q., E-mail: weare@uchicago.edu [Department of Mathematics, University of Chicago, Chicago, Illinois 60637 (United States); Weare, John H., E-mail: jweare@ucsd.edu [Department of Chemistry and Biochemistry, University of California, San Diego, La Jolla, California 92093 (United States)

    2013-08-21

    Parallel in time simulation algorithms are presented and applied to conventional molecular dynamics (MD) and ab initio molecular dynamics (AIMD) models of realistic complexity. Assuming that a forward time integrator, f (e.g., Verlet algorithm), is available to propagate the system from time t{sub i} (trajectory positions and velocities x{sub i} = (r{sub i}, v{sub i})) to time t{sub i+1} (x{sub i+1}) by x{sub i+1} = f{sub i}(x{sub i}), the dynamics problem spanning an interval from t{sub 0}…t{sub M} can be transformed into a root finding problem, F(X) = [x{sub i} − f(x{sub (i−1})]{sub i} {sub =1,M} = 0, for the trajectory variables. The root finding problem is solved using a variety of root finding techniques, including quasi-Newton and preconditioned quasi-Newton schemes that are all unconditionally convergent. The algorithms are parallelized by assigning a processor to each time-step entry in the columns of F(X). The relation of this approach to other recently proposed parallel in time methods is discussed, and the effectiveness of various approaches to solving the root finding problem is tested. We demonstrate that more efficient dynamical models based on simplified interactions or coarsening time-steps provide preconditioners for the root finding problem. However, for MD and AIMD simulations, such preconditioners are not required to obtain reasonable convergence and their cost must be considered in the performance of the algorithm. The parallel in time algorithms developed are tested by applying them to MD and AIMD simulations of size and complexity similar to those encountered in present day applications. These include a 1000 Si atom MD simulation using Stillinger-Weber potentials, and a HCl + 4H{sub 2}O AIMD simulation at the MP2 level. The maximum speedup ((serial execution time)/(parallel execution time) ) obtained by parallelizing the Stillinger-Weber MD simulation was nearly 3.0. For the AIMD MP2 simulations, the algorithms achieved speedups of up

  17. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  18. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  19. Re-use of Low Bandwidth Equipment for High Bit Rate Transmission Using Signal Slicing Technique

    DEFF Research Database (Denmark)

    Wagner, Christoph; Spolitis, S.; Vegas Olmos, Juan José

    : Massive fiber-to-the-home network deployment requires never ending equipment upgrades operating at higher bandwidth. We show effective signal slicing method, which can reuse low bandwidth opto-electronical components for optical communications at higher bit rates.......: Massive fiber-to-the-home network deployment requires never ending equipment upgrades operating at higher bandwidth. We show effective signal slicing method, which can reuse low bandwidth opto-electronical components for optical communications at higher bit rates....

  20. Thin slices of friendship: do non-verbal behaviors predict first impressions during getting acquainted interactions?

    OpenAIRE

    Urgancı, Betül

    2017-01-01

    Cataloged from PDF version of article. Thesis (M.S.): Bilkent University, Department of Psychology, İhsan Doğramacı Bilkent University, 2017. Includes bibliographical references (leaves 28-32). Does a very brief observation of a person predict first impressions? Prior research has shown that these brief observations, called thin slices, predict many psychological outcomes such as individual performance. However, there is a not much research investigating whether thin slices predict f...