  1. Tibial nerve somatosensory evoked potentials in dogs with degenerative lumbosacral stenosis.

    Science.gov (United States)

    Meij, Björn P; Suwankong, Niyada; van den Brom, Walter E; Venker-van Haagen, Anjop J; Hazewinkel, Herman A W

    2006-02-01

    To determine somatosensory evoked potentials (SEPs) in dogs with degenerative lumbosacral stenosis (DLS) and in healthy dogs. Clinical and experimental study. Dogs with DLS (n = 21) and 11 clinically normal dogs, age, and weight matched. Under anesthesia, the tibial nerve was stimulated at the caudolateral aspect of the stifle, and lumbar SEP (LSEP) were recorded percutaneously from S1 to T13 at each interspinous space. Cortical SEP (CSEP) were recorded from the scalp. LSEP were identified as the N1-P1 (latency 3-6 ms) and N2-P2 (latency 7-13 ms) wave complexes in the recordings of dogs with DLS and control dogs. Latency of N1-P1 increased and that of N2-P2 decreased as the active recording electrode was moved cranially from S1 to T13. Compared with controls, latencies were significantly delayed in DLS dogs: .8 ms for N1-P1 and 1.7 ms for the N2-P2 complex. CSEP were not different between groups. Surface needle recording of tibial nerve SEP can be used to monitor somatosensory nerve function of pelvic limbs in dogs. In dogs with DLS, the latency of LSEP, but not of CSEP, is prolonged compared with normal dogs. In dogs with lumbosacral pain from DLS, the cauda equina compression is sufficient to affect LSEP at the lumbar level.

  2. Changes of medium-latency SEP-components following peripheral nerve lesion

    Directory of Open Access Journals (Sweden)

    Straschill Max

    2006-10-01

    Full Text Available Abstract Background Animal studies have demonstrated complex cortical reorganization following peripheral nerve lesion. Central projection fields of intact nerves supplying skin areas which border denervated skin, extended into the deafferentiated cortical representation area. As a consequence of nerve lesions and subsequent reorganization an increase of the somatosensory evoked potentials (SEPs was observed in cats when intact neighbouring nerves were stimulated. An increase of SEP-components of patients with nerve lesions may indicate a similar process of posttraumatic plastic cortical reorganization. Methods To test if a similar process of post-traumatic plastic cortical reorganization does occur in humans, the SEP of intact neighbouring hand nerves were recorded in 29 patients with hand nerve lesions. To hypothetically explain the observed changes of SEP-components, SEP recording following paired stimulation of the median nerve was performed in 12 healthy subjects. Results Surprisingly 16 of the 29 patients (55.2% showed a reduction or elimination of N35, P45 and N60. Patients with lesions of two nerves showed more SEP-changes than patients with a single nerve lesion (85.7%; 6/7 nerves; vs. 34.2%; 13/38 nerves; Fisher's exact test, p Conclusion The results of the present investigation do not provide evidence of collateral innervation of peripherally denervated cortical neurons by neurons of adjacent cortical representation areas. They rather suggest that secondary components of the excitatory response to nerve stimulation are lost in cortical areas, which surround the denervated region.

  3. Transcutaneous stimulation of the posterior tibial nerve for treating refractory urge incontinence of idiopathic and neurogenic origin.

    Science.gov (United States)

    Valles-Antuña, C; Pérez-Haro, M L; González-Ruiz de L, C; Quintás-Blanco, A; Tamargo-Diaz, E M; García-Rodríguez, J; San Martín-Blanco, A; Fernandez-Gomez, J M

    2017-09-01

    To assess the efficacy of treatment with transcutaneous posterior tibial nerve stimulation (TPTNS) in patients with urge urinary incontinence, of neurogenic or nonneurogenic origin, refractory to first-line therapeutic options. We included 65 patients with urge urinary incontinence refractory to medical treatment. A case history review, a urodynamic study and a somatosensory evoked potentials (SEP) study were conducted before the TPTNS, studying the functional urological condition by means of a voiding diary. The treatment consisted of 10 weekly sessions of TPTNS lasting 30minutes. Some 57.7% of the patients showed abnormal tibial SEPs, and 42% showed abnormal pudendal SEPs. A statistically significant symptomatic improvement was observed in all clinical parameters after treatment with TPTNS, and 66% of the patients showed an overall improvement, regardless of sex, the presence of underlying neurological disorders, detrusor hyperactivity in the urodynamic study or SEP disorders. There were no adverse effects during the treatment. TPTNS is an effective and well tolerated treatment in patients with urge incontinence refractory to first-line therapies and should be offered early in the treatment strategy. New studies are needed to identify the optimal parameters of stimulation, the most effective treatment protocols and long-term efficacy, as well as its applicability to patients with a neurogenic substrate. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. High resolution ultrasonography of the tibial nerve in diabetic peripheral neuropathy.

    Science.gov (United States)

    Singh, Kunwarpal; Gupta, Kamlesh; Kaur, Sukhdeep

    2017-12-01

    High-resolution ultrasonography of the tibial nerve is a fast and non invasive tool for diagnosis of diabetic peripheral neuropathy. Our study was aimed at finding out the correlation of the cross sectional area and maximum thickness of nerve fascicles of the tibial nerve with the presence and severity of diabetic peripheral neuropathy. 75 patients with type 2 diabetes mellitus clinically diagnosed with diabetic peripheral neuropathy were analysed, and the severity of neuropathy was determined using the Toronto Clinical Neuropathy Score. 58 diabetic patients with no clinical suspicion of diabetic peripheral neuropathy and 75 healthy non-diabetic subjects were taken as controls. The cross sectional area and maximum thickness of nerve fascicles of the tibial nerves were calculated 3 cm cranial to the medial malleolus in both lower limbs. The mean cross sectional area (22.63 +/- 2.66 mm 2 ) and maximum thickness of nerve fascicles (0.70 mm) of the tibial nerves in patients with diabetic peripheral neuropathy compared with both control groups was significantly larger, and statistically significant correlation was found with the Toronto Clinical Neuropathy Score ( p peripheral neuropathy had a larger mean cross sectional area (14.40 +/- 1.72 mm 2 ) and maximum thickness of nerve fascicles of the tibial nerve (0.40 mm) than healthy non-diabetic subjects (12.42 +/- 1.01 mm 2 and 0.30 mm respectively). The cross sectional area and maximum thickness of nerve fascicles of the tibial nerve is larger in diabetic patients with or without peripheral neuropathy than in healthy control subjects, and ultrasonography can be used as a good screening tool in these patients.

  5. Tibial nerve intraneural ganglion cyst in a 10-year-old boy

    Energy Technology Data Exchange (ETDEWEB)

    Squires, Judy H. [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati, OH (United States); Emery, Kathleen H.; Johnson, Neil [Cincinnati Children' s Hospital Medical Center, Division of Radiology, Cincinnati, OH (United States); Sorger, Joel [Cincinnati Children' s Hospital Medical Center, Division of Orthopedics, Cincinnati, OH (United States)

    2014-04-15

    Intraneural ganglion cysts are uncommon cystic lesions of peripheral nerves that are typically encountered in adults. In the lower extremity, the peroneal nerve is most frequently affected with involvement of the tibial nerve much less common. This article describes a tibial intraneural ganglion cyst in a 10-year-old boy. Although extremely rare, intraneural ganglion cysts of the tibial nerve should be considered when a nonenhancing cystic structure with intra-articular extension is identified along the course of the nerve. This report also details the unsuccessful attempt at percutaneous treatment with US-guided cyst aspiration and steroid injection, an option recently reported as a viable alternative to open surgical resection. (orig.)

  6. Diffusion-weighted MR neurography of the tibial nerve and the common peroneal nerve with different motion probing gradients

    International Nuclear Information System (INIS)

    Zhao Lianxin; Wang Guangbin; Liu Yubo; Wu Lebin; Bai Xue; Yang Li; Chen Weibo

    2014-01-01

    Objective: To compare the image quality of diffusion-weighted MR neurography (DW-MRN) of the tibial nerve and the common peroneal nerve prospectively using different motion probing gradients (MPGs). Methods: A total of 21 healthy volunteers underwent DW-MRN at the knee (unilateral imaging) on a 3.0 T magnetic resonance system with unidirectional MPGs. The protocol included anterior-posterior unidirectional, right-left unidirectional, three-directional and six-directional MPGs. The apparent SNR and CNR of tibial nerve and common peroneal nerve were calculated. Three-dimensional MIP images of the nerves were evaluated blindly by two radiologists using a four-point grading scale on basis of entirety depiction and the signal intensity. Significance was determined by using Friedman and paired Wilcoxon tests. Results: The SNR of tibial nerves on DW-MRN with anterior-posterior, right-left, three directional and six directional MPGs were 4.17 (2.70-5.65), 4.35 (0.47-4.69), 3.46 (2.27-4.62) and 3.30 (2.06-4.43), respectively. CNR were 0.61 (0.46-0.70), 0.63 (0.36-0.73), 0.55 (0.39-0.64) and 0.53(0.35-0.63), respectively. The scores of tibial nerve image quality were 4.0 (2.0-4.0), 4.0 (3.0-4.0), 2.5 (2.0-3.5), 2.0 (1.0-2.5), respectively. Interobserver agreement was good and the Kappa value was 0.69 (P<0.05). The SNR of the common peroneal nerves on DW-MRN with anterior-posterior, right-left, three directional and six directional MPGs were 3.05 (2.30-4.20), 3.05 (2.26-4.34), 2.72 (1.84-13.80) and 2.68 (1.87-3.67), respectively. CNR were 0.51 (0.39-0.62), 0.51 (0.39-0.63), 0.46(0.30-0.86) and 0.46 (0.30-0.57), respectively. The scores of the common peroneal nerve image quality were 3.5 (2.0-4.0), 4.0 (2.0-4.0), 2.0 (1.0-3.0) and 2.0 (1.0-2.5), respectively. Interobserver agreement was good and the Kappa value was 0.70 (P<0.05). For SNR, CNR and nerve image quality of the tibial nerves and the common peroneal nerves, there were significant differences among different MPGs (

  7. [The speed of nerve-conduction after micro-surgical suture of the tibial nerve of the rabbit (author's transl)].

    Science.gov (United States)

    Weigert, M; Mellerowicz, H; Werhahn, C

    1975-10-01

    Isolated division of the tibial nerve in the thigh preserving the peroneal and sural nerves does not cause loss of normal position of the animal, in particular of sitting. Nor does it lead to pressure sores. The animals are fitter then after division of the sciatic nerve. Microsurgical suture of the isolated tibial nerve in the thigh of the rabbit with 1 or 2 simple sutures with 10 x 0 thread show that an average recovery can be achieved in over 80 per cent. As few sutures as possible should be used. Otherwise there with be scarring and no return of function.

  8. Scaffoldless tissue-engineered nerve conduit promotes peripheral nerve regeneration and functional recovery after tibial nerve injury in rats

    Institute of Scientific and Technical Information of China (English)

    Aaron M. Adams; Keith W. VanDusen; Tatiana Y. Kostrominova; Jacob P. Mertens; Lisa M. Larkin

    2017-01-01

    Damage to peripheral nerve tissue may cause loss of function in both the nerve and the targeted muscles it innervates. This study compared the repair capability of engineered nerve conduit (ENC), engineered fibroblast conduit (EFC), and autograft in a 10-mm tibial nerve gap. ENCs were fabricated utilizing primary fibroblasts and the nerve cells of rats on embryonic day 15 (E15). EFCs were fabricated utilizing primary fi-broblasts only. Following a 12-week recovery, nerve repair was assessed by measuring contractile properties in the medial gastrocnemius muscle, distal motor nerve conduction velocity in the lateral gastrocnemius, and histology of muscle and nerve. The autografts, ENCs and EFCs reestablished 96%, 87% and 84% of native distal motor nerve conduction velocity in the lateral gastrocnemius, 100%, 44% and 44% of native specific force of medical gastrocnemius, and 63%, 61% and 67% of native medial gastrocnemius mass, re-spectively. Histology of the repaired nerve revealed large axons in the autograft, larger but fewer axons in the ENC repair, and many smaller axons in the EFC repair. Muscle histology revealed similar muscle fiber cross-sectional areas among autograft, ENC and EFC repairs. In conclusion, both ENCs and EFCs promot-ed nerve regeneration in a 10-mm tibial nerve gap repair, suggesting that the E15 rat nerve cells may not be necessary for nerve regeneration, and EFC alone can suffice for peripheral nerve injury repair.

  9. Study of the anatomy of the tibial nerve and its branches in the distal medial leg

    Science.gov (United States)

    Torres, André Leal Gonçalves; Ferreira, Marcus Castro

    2012-01-01

    Objective Determine, through dissection in fresh cadavers, the topographic anatomy of the tibial nerve and its branches at the ankle, in relation to the tarsal tunnel. Methods Bilateral dissections were performed on 26 fresh cadavers and the locations of the tibial nerve bifurcation and its branches were measured in millimeters. For the calcaneal branches, the amount and their respective nerves of origin were also analyzed. Results The tibial nerve bifurcation occurred under the tunnel in 88% of the cases and proximally in 12%. As for the calcaneal branches, the medial presented with one (58%), two (34%) and three (8%) branches, with the most common source occurring in the tibial nerve (90%) and the lower with a single branch per leg and lateral plantar nerve as the most common origin (70%). Level of Evidence, V Expert opinion. PMID:24453596

  10. Tibial nerve stimulation for overactive bladder syndrome unresponsive to medical therapy.

    Science.gov (United States)

    Ridout, A E; Yoong, W

    2010-02-01

    Overactive bladder syndrome is defined as a symptom syndrome which includes urinary urgency, with or without urge incontinence, usually accompanied by frequency (>8 micturitions/24 h) and nocturia. Conservative treatment usually comprises behavioural techniques, bladder retraining, pelvic floor re-education and pharmacotherapy but up to 30% of patients will remain refractory to treatment. Although second-line treatment options such as sacral nerve stimulation and intravesical botulinum A injections are valuable additions to the therapeutic arsenal, they are relatively invasive and can have serious side-effects. Inhibition of detrusor activity by peripheral neuromodulation of the posterior tibial nerve was first described in 1983, with recent authors further confirming a 60-80% positive response rate. This review was undertaken to examine published literature on percutaneous tibial nerve stimulation and to discuss outcome measures, maintenance therapy and prognostic factors of this technique.

  11. Cystic degeneration of the tibial nerve. Magnetic resonance neurography and sonography appearances of an intraneural ganglion cyst

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio Silveira, Claudio Regis [Sao Carlos Imaging/Sao Carlos Hospital, Musculoskeletal Imaging Division, Fortaleza, CE (Brazil); Maia Vieira, Clarissa Gadelha; Machado Pereira, Brenda [Sao Carlos Imaging/Sao Carlos Hospital, Fortaleza, CE (Brazil); Pinto Neto, Luiz Holanda [Articular Clinic, Fortaleza, CE (Brazil); Chhabra, Avneesh [UT Southwestern, Radiology and Orthopaedic Surgery, Dallas, TX (United States)

    2017-12-15

    Extra- and intraneural ganglion cysts have been described in the literature. The tibial nerve ganglion is uncommon and its occurrence without intra-articular extension is atypical. The pathogenesis of cystic degeneration localized to connective and perineural tissue secondary to chronic mechanical irritation or idiopathic mucoid degeneration is hypothesized. Since the above pathology is extremely rare and the magnetic resonance imaging examination detects the defining characteristics of the intrinsic alterations of the tibial nerve, the authors illustrate such a case of tibial intaneural ganglion cyst with its magnetic resonance neurography and sonography appearances. (orig.)

  12. Primary neurolymphoma of the tibial nerve: A case report with characteristic MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Eun; An, Ji Young; Park, Ji Seon; Ryu, Kyung Nam; Moon, Sung Kyung [Dept. of Radiology, Kyung Hee University Hospital, Seoul (Korea, Republic of)

    2016-11-15

    Primary neurolymphoma (NL) involving the peripheral nervous system is a rare disease that involves the invasion of a nerve or nerve plexus by neoplastic lymphocytes. Although there have been a few reported clinical and pathological cases presenting as primary NL involving the peripheral nerve, the detailed radiological features of NL have not yet been discussed. In this report, we present a case of primary NL involving the tibial nerve and describe the detailed imaging findings on MRI including features used for differential diagnosis.

  13. Magnetic Resonance Neurography Visualizes Abnormalities in Sciatic and Tibial Nerves in Patients With Type 1 Diabetes and Neuropathy.

    Science.gov (United States)

    Vaeggemose, Michael; Pham, Mirko; Ringgaard, Steffen; Tankisi, Hatice; Ejskjaer, Niels; Heiland, Sabine; Poulsen, Per L; Andersen, Henning

    2017-07-01

    This study evaluates whether diffusion tensor imaging magnetic resonance neurography (DTI-MRN), T2 relaxation time, and proton spin density can detect and grade neuropathic abnormalities in patients with type 1 diabetes. Patients with type 1 diabetes ( n = 49) were included-11 with severe polyneuropathy (sDPN), 13 with mild polyneuropathy (mDPN), and 25 without polyneuropathy (nDPN)-along with 30 healthy control subjects (HCs). Clinical examinations, nerve conduction studies, and vibratory perception thresholds determined the presence and severity of DPN. DTI-MRN covered proximal (sciatic nerve) and distal (tibial nerve) nerve segments of the lower extremity. Fractional anisotropy (FA) and the apparent diffusion coefficient (ADC) were calculated, as were T2 relaxation time and proton spin density obtained from DTI-MRN. All magnetic resonance findings were related to the presence and severity of neuropathy. FA of the sciatic and tibial nerves was lowest in the sDPN group. Corresponding with this, proximal and distal ADCs were highest in patients with sDPN compared with patients with mDPN and nDPN, as well as the HCs. DTI-MRN correlated closely with the severity of neuropathy, demonstrating strong associations with sciatic and tibial nerve findings. Quantitative group differences in proton spin density were also significant, but less pronounced than those for DTI-MRN. In conclusion, DTI-MRN enables detection in peripheral nerves of abnormalities related to DPN, more so than proton spin density or T2 relaxation time. These abnormalities are likely to reflect pathology in sciatic and tibial nerve fibers. © 2017 by the American Diabetes Association.

  14. Study of tibial nerve regeneration in Wistar rats in primary neurorrhaphy with and without gap, wrapped in vein segments.

    Science.gov (United States)

    Bastos Dos Santos, Ewerton; Fernandes, Marcela; Gomes Dos Santos, João Baptista; Mattioli Leite, Vilnei; Valente, Sandra Gomes; Faloppa, Flávio

    2012-01-01

    This study compared nerve regeneration in Wistar rats, using epineural neurorrhaphy with a gap of 1.0 mm and without a gap, both wrapped with jugular vein tubes. Motor neurons in the spinal cord between L3 and S1 were used for the count, marked by exposure of the tibial nerve to Fluoro-Gold (FG). The tibial nerves on both sides were cut and sutured, with a gap on one side and no gap in the other. The sutures were wrapped with a jugular vein. Four months after surgery the tibial nerves were exposed to Fluoro-Gold and the motor neuron count performed in the spinal cord. The results were statistically analyzed by the paired Wilcoxon test. There was a statistical difference between the groups with and without gap in relation to the motor neuron count (p=0.013). The epineural neurorraphy without gap wrapped with jugular vein showed better results for nerve regeneration than the same procedure with gap. Experimental Study .

  15. Which Ultrasound-Guided Sciatic Nerve Block Strategy Works Faster? Prebifurcation or Separate Tibial-Peroneal Nerve Block? A Randomized Clinical Trial.

    Science.gov (United States)

    Faiz, Seyed Hamid Reza; Imani, Farnad; Rahimzadeh, Poupak; Alebouyeh, Mahmoud Reza; Entezary, Saeed Reza; Shafeinia, Amineh

    2017-08-01

    Peripheral nerve block is an accepted method in lower limb surgeries regarding its convenience and good tolerance by the patients. Quick performance and fast sensory and motor block are highly demanded in this method. The aim of the present study was to compare 2 different methods of sciatic and tibial-peroneal nerve block in lower limb surgeries in terms of block onset. In this clinical trial, 52 candidates for elective lower limb surgery were randomly divided into 2 groups: sciatic nerve block before bifurcation (SG; n = 27) and separate tibial-peroneal nerve block (TPG; n = 25) under ultrasound plus nerve stimulator guidance. The mean duration of block performance, as well as complete sensory and motor block, was recorded and compared between the groups. The mean duration of complete sensory block in the SG and TPG groups was 35.4 ± 4.1 and 24.9 ± 4.2 minutes, respectively, which was significantly lower in the TPG group (P = 0.001). The mean duration of complete motor block in the SG and TPG groups was 63.3 ± 4.4 and 48.4 ± 4.6 minutes, respectively, which was significantly lower in the TPG group (P = 0.001). No nerve injuries, paresthesia, or other possible side effects were reported in patients. According to the present study, it seems that TPG shows a faster sensory and motor block than SG.

  16. Percutaneous tibial nerve stimulation vs sacral nerve stimulation for faecal incontinence: a comparative case-matched study.

    Science.gov (United States)

    Al Asari, S; Meurette, G; Mantoo, S; Kubis, C; Wyart, V; Lehur, P-A

    2014-11-01

    The study assessed the initial experience with posterior tibial nerve stimulation (PTNS) for faecal incontinence and compared it with sacral nerve stimulation (SNS) performed in a single centre during the same timespan. A retrospective review of a prospectively collected database was conducted at the colorectal unit, University Hospital, Nantes, France, from May 2009 to December 2010. Seventy-eight patients diagnosed with chronic severe faecal incontinence underwent neurostimulation including PTNS in 21 and SNS in 57. The main outcome measures were faecal incontinence (Wexner score) and quality of life (Fecal Incontinence Quality of Life, FIQL) scores in a short-term follow-up. No significant differences were observed in patients' characteristics. Of 57 patients having SNS, 18 (32%) failed peripheral nerve evaluation and 39 (68%) received a permanent implant. Two (5%) developed a wound infection. No adverse effects were recorded in the PTNS group. There was no significant difference in the mean Wexner and FIQL scores between patients having PTNS and SNS at 6 (P = 0.39 and 0.09) and 12 months (P = 0.79 and 0.37). A 50% or more improvement in Wexner score was seen at 6 and 12 months in 47% and 30% of PTNS patients and in 50% and 58% of SNS patients with no significant difference between the groups. Posterior tibial nerve stimulation is a valid method of treating faecal incontinence in the short term when conservative treatment has failed. It is easier, simpler, cheaper and less invasive than SNS with a similar short-term outcome. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  17. DIAGNOSTIC BLOCKS OF THE TIBIAL NERVE IN SPASTIC HEMIPARESIS - EFFECTS ON CLINICAL, ELECTROPHYSIOLOGICAL AND GAIT PARAMETERS

    NARCIS (Netherlands)

    ARENDZEN, JH; VANDUIJN, H; BECKMANN, MKF; HARLAAR, J; VOGELAAR, TW; PREVO, AJH

    The value of a diagnostic block (DB) of the tibial nerve in 17 hemiparetic patients with gait disturbances was investigated. The purpose of this study was to find instruments that help to select patients who will benefit from a long lasting peripheral nerve block. The manually elicited ankle clonus

  18. Pedicled Instep Flap and Tibial Nerve Reconstruction in a Cynomolgus Monkey [Macaca fascicularis

    Directory of Open Access Journals (Sweden)

    Ruth Weiss

    2016-01-01

    Full Text Available A male cynomolgus monkey experienced extensive soft tissue trauma to the right caudal calf area. Some weeks after complete healing of the original wounds, the monkey developed a chronic pressure sore on plantar surface of the heel of its right foot. A loss of sensitivity in the sole of the foot was hypothesized. The skin defect was closed by a medial sensate pedicled instep flap followed by counter transplantation of a full thickness graft from the interdigital webspace. The integrity of the tibial nerve was revised and reconstructed by means of the turnover flap technique. Both procedures were successful. This is an uncommon case in an exotic veterinary patient as it demonstrates a reconstructive skin flap procedure for the treatment of a chronic, denervated wound in combination with the successful reconstruction of 2.5 cm gap in the tibial nerve.

  19. Antinociceptive and antiallodynic effects of Momordica charantia L. in tibial and sural nerve transection-induced neuropathic pain in rats.

    Science.gov (United States)

    Jain, Vivek; Pareek, Ashutosh; Paliwal, Nishant; Ratan, Yashumati; Jaggi, Amteshwar Singh; Singh, Nirmal

    2014-02-01

    This study was designed to investigate the ameliorative potential of Momordica charantia L. (MC) in tibial and sural nerve transection (TST)-induced neuropathic pain in rats. TST was performed by sectioning tibial and sural nerve portions (2 mm) of the sciatic nerve, and leaving the common peroneal nerve intact. Acetone drop, pin-prick, hot plate, paint-brush, and walking track tests were performed to assess cold allodynia, mechanical and heat hyperalgesia, and dynamic mechanical allodynia and tibial functional index, respectively. The levels of tumour necrosis factor (TNF)-alpha and thio-barbituric acid reactive substances (TBARS) were measured in the sciatic nerve as an index of inflammation and oxidative stress. MC (all doses, orally, once daily) was administered to the rats for 24 consecutive days. TST led to significant development of cold allodynia, mechanical and heat hyperalgesia, dynamic mechanical allodynia, and functional deficit in walking along with rise in the levels of TBARS and TNF-alpha. Administration of MC (200, 400, and 800 mg/kg) significantly attenuated TST-induced behavioural and biochemical changes. Furthermore, pretreatment of BADGE (120 mg/kg, intraperitoneally) abolished the protective effect of MC in TST-induced neuropathic pain. Collectively, it is speculated that PPAR-gamma agonistic activity, anti-inflammatory, and antioxidative potential is critical for antinociceptive effect of MC in neuropathic pain.

  20. MR T2 value of the tibial nerve can be used as a potential non-invasive and quantitative biomarker for the diagnosis of diabetic peripheral neuropathy

    International Nuclear Information System (INIS)

    Wang, Dongye; Duan, Xiaohui; Yang, Zehong; Bai, Zhiqiang; Hu, Huijun; Shen, Jun; Wang, Chuan; Yan, Li

    2018-01-01

    To determine the role of quantitative tibial nerve T2 value in the diagnosis of diabetic peripheral neuropathy (DPN). MR imaging and T2 mapping of the tibial nerve were performed in 22 diabetic patients with DPN, 20 diabetic patients without DPN and 20 healthy controls. Nerve T2 values were measured, and compared using the Mann-Whitney U test. Receiver operating characteristic (ROC) curve analysis was used to determine the diagnostic ability of T2 value to identify DPN. Nerve T2 value was 55.06 ± 4.05 ms, 48.91 ± 3.06 ms and 45.61 ± 1.86 ms in patients with DPN, patients without DPN and controls, respectively. Patients with DPN had significantly higher nerve T2 values than patients without DPN (P < 0.001). Nerve T2 values in patients without DPN were higher than in controls (P < 0.001). ROC analysis showed that T2 values had a diagnostic sensitivity of 81.8 %, specificity of 89.2 % and area under the curve of 0.922 for identifying patients with DPN from patients without DPN plus controls when the cutoff point was 51.34 ms. T2 value of the tibial nerve can be used as an alternative, non-invasive quantitative parameter to assess DPN in diabetic patients. circle Tibial nerves in patients with DPN showed T2 hyperintensity and enlargement. (orig.)

  1. MR T2 value of the tibial nerve can be used as a potential non-invasive and quantitative biomarker for the diagnosis of diabetic peripheral neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dongye; Duan, Xiaohui; Yang, Zehong; Bai, Zhiqiang; Hu, Huijun; Shen, Jun [Sun Yat-Sen University, Department of Radiology, Sun Yat-Sen Memorial Hospital, Guangzhou, Guangdong (China); Wang, Chuan; Yan, Li [Sun Yat-Sen University, Department of Endocrinology, Sun Yat-Sen Memorial Hospital, Guangzhou, Guangdong (China)

    2018-03-15

    To determine the role of quantitative tibial nerve T2 value in the diagnosis of diabetic peripheral neuropathy (DPN). MR imaging and T2 mapping of the tibial nerve were performed in 22 diabetic patients with DPN, 20 diabetic patients without DPN and 20 healthy controls. Nerve T2 values were measured, and compared using the Mann-Whitney U test. Receiver operating characteristic (ROC) curve analysis was used to determine the diagnostic ability of T2 value to identify DPN. Nerve T2 value was 55.06 ± 4.05 ms, 48.91 ± 3.06 ms and 45.61 ± 1.86 ms in patients with DPN, patients without DPN and controls, respectively. Patients with DPN had significantly higher nerve T2 values than patients without DPN (P < 0.001). Nerve T2 values in patients without DPN were higher than in controls (P < 0.001). ROC analysis showed that T2 values had a diagnostic sensitivity of 81.8 %, specificity of 89.2 % and area under the curve of 0.922 for identifying patients with DPN from patients without DPN plus controls when the cutoff point was 51.34 ms. T2 value of the tibial nerve can be used as an alternative, non-invasive quantitative parameter to assess DPN in diabetic patients. circle Tibial nerves in patients with DPN showed T2 hyperintensity and enlargement. (orig.)

  2. Management of overactive bladder review: the role of percutaneous tibial nerve stimulation

    Directory of Open Access Journals (Sweden)

    Elita Wibisono

    2017-01-01

    Full Text Available Overactive bladder (OAB is a common condition that is experienced by around 455 million people (11% of the world population and associated with significant impact in patients’ quality of life. The first line treatments of OAB are conservative treatment and anti-muscarinic medication. For the refractory OAB patients, the treatment options available are surgical therapy, electrical stimulation, and botulinum toxin injection. Among them, percutaneous tibial nerve stimulation (PTNS is a minimally invasive option that aims to stimulate sacral nerve plexus, a group of nerve that is responsible for regulation of bladder function. After its approval by food and drug administration (FDA in 2007, PTNS revealed considerable promise in OAB management. In this review, several non-comparative and comparative studies comparing PTNS with sham procedure, anti-muscarinic therapy, and multimodal therapy combining PTNS and anti-muscarinic had supportive data to this consideration.

  3. Giant SEPs and SEP-recovery function in Unverricht-Lundborg disease.

    Science.gov (United States)

    Visani, E; Canafoglia, L; Rossi Sebastiano, D; Agazzi, P; Panzica, F; Scaioli, V; Ciano, C; Franceschetti, S

    2013-05-01

    To evaluate the relationship between sensory hyperexcitability as revealed by giant SEPs and the SEP recovery function (SEP-R) in a series of patient with progressive myoclonic epilepsy of Unverricht-Lundborg type, identified as epilepsy, progressive myoclonic 1A (EPM1A), MIM #254800. We evaluated SEPs by applying median nerve stimuli and SEP-R using paired stimuli at inter-stimulus intervals (ISIs) of between 20 and 600 ms in 25 patients and 20 controls. The SEPs were considered "giant" if the N20P25 and P25N33 amplitudes exceeded normal mean values by +3SD. During the paired-stimulus protocol, the SEPs elicited by the second stimulus (S2) were detectable at all ISIs but consistently suppressed in the 13 patients with giant SEPs reflecting a significantly delayed SEP-R. Maximal suppression roughly corresponded to the plateau of a broad middle latency (>100 ms) wave pertaining to the S1 response. The cortical processing dysfunction generating giant SEPs in EPM1A patients consistently combines with a long-lasting suppression of hyperexcitability that leads to a delayed giant SEP-R without obstructing the response to incoming stimuli. The delayed SEP-R is not due to true inhibition but the suppression of aberrant hyper-synchronisation sustaining giant SEPs. A broad middle latency SEP component adds a significantly suppressive effect. This suggests that cortico-subcortical circuitries contribute to both the gigantism and the delayed SEP-R. Copyright © 2012 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Tibial nerve (image)

    Science.gov (United States)

    ... nerve is commonly injured by fractures or other injury to the back of the knee or the lower leg. It may be affected by systemic diseases such as diabetes mellitus. The nerve can also be damaged by pressure from a tumor, abscess, or bleeding into the ...

  5. Posterior Tibial Neuropathy by a Baker’s Cyst: Case Report

    OpenAIRE

    Lee, Ji-Hyun; Jun, Jae-Bum; Choi, Choong-Hyeok; Park, Si-Bog; Yoo, Dae-Hyun; Hong, Eun-Kyung; Kim, Seong Yoon

    2000-01-01

    Baker’s cysts are rare cause of peripheral nerve entrapment and only a few cases of tibial nerve entrapment resulting from the popliteal cyst in the calf muscle have been reported in the literature. We present a case of rheumatoid arthritis complicated by a Baker’s cyst with a tibial nerve entrapment. It is important to diagnose a Baker’s cyst early and to differentiate it from thrombophlebitis, a popliteal aneurysm, tumor or muscle tear to effect optimal therapy and to obviate a potential ne...

  6. Posterior tibial neuropathy by a Baker's cyst: case report.

    Science.gov (United States)

    Lee, J H; Jun, J B; Lee, H S; Yun, H R; Choi, C H; Park, S B; Hong, E K; Yoo, D H; Kim, S Y

    2000-01-01

    Baker's cysts are rare cause of peripheral nerve entrapment and only a few cases of tibial nerve entrapment resulting from the popliteal cyst in the calf muscle have been reported in the literature. We present a case of rheumatoid arthritis complicated by a Baker's cyst with a tibial nerve entrapment. It is important to diagnose a Baker's cyst early and to differentiate it from thrombophlebitis, a popliteal aneurysm, tumor or muscle tear to effect optimal therapy and to obviate a potential neuropathy. Prompt recognition of these cases may save the patients unnecessary procedures and delay in treatment.

  7. Vascularized nerve grafts for lower extremity nerve reconstruction.

    Science.gov (United States)

    Terzis, Julia K; Kostopoulos, Vasileios K

    2010-02-01

    Vascularized nerve grafts (VNG) were introduced in 1976 but since then, there have been no reports of their usage in lower extremity reconstruction systematically. The factors influencing outcomes as well as a comparison with conventional nerve grafts will be presented.Since 1981, 14 lower extremity nerve injuries in 12 patients have been reconstructed with VNG. Common peroneal nerve was injured in 12 and posterior tibial nerve in 5 patients. The level of the injury was at the knee or thigh. Twelve sural nerves were used as VNG with or without concomitant vascularized posterior calf fascia.All patients regained improved sensibility and adequate posterior tibial nerve function. For common peroneal nerve reconstructions, all patients with denervation time less than 6 months regained muscle strength of grade at least 4, even when long grafts were used for defects of 20 cm or more. Late cases, yielded inadequate muscle function even with the use of VNG.Denervation time of 6 months or less was critical for reconstruction with vascularized nerve graft. Not only the results were statistically significant compared with late cases, but also all early operated patients achieved excellent results. VNG are strongly recommended in traction avulsion injuries of the lower extremity with lengthy nerve damage.

  8. Early impairment of somatosensory evoked potentials in very young children with achondroplasia with foramen magnum stenosis.

    Science.gov (United States)

    Fornarino, Stefania; Rossi, Daniela Paola; Severino, Mariasavina; Pistorio, Angela; Allegri, Anna Elsa Maria; Martelli, Simona; Doria Lamba, Laura; Lanteri, Paola

    2017-02-01

    To evaluate the contribution of somatosensory evoked potentials after median nerve (MN-SEPs) and posterior tibial nerve (PTN-SEPs) stimulation in functional assessment of cervical and lumbar spinal stenosis in children with achondroplasia. We reviewed MN-SEPs, PTN-SEPs, and spinal magnetic resonance imaging (MRI) examinations performed in 58 patients with achondroplasia (25 males, 33 females; age range 21d-16y 10mo; mean age 4y 3mo [SD 4y 1mo]). Patients were subdivided into four age categories: achondroplasia, the cortical component of PTN-SEPs is more sensitive than the cortical component and central conduction time of MN-SEPs in detection of cervical spinal cord compression at early ages. © 2016 Mac Keith Press.

  9. Myelography for nerve root avulsion in birth palsy

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Tsutomu; Mitomo, Masanori; Hirabuki, Norio; Miura, Takashi; Kawai, Ryuji; Imakita, Satoshi; Harada, Koshi; Nakamura, Hironobu; Kozuka, Takahiro (Osaka Univ. (Japan). Faculty of Medicine)

    1990-04-01

    Myelography and CT myelography (CMT) were reviewed in 18 cases of birth palsy with clinically suspected avulsion injury. Root-somatosensory evoked potential (root-SEP) was also reviewed for myelographic evaluation of the nerve root avolusion in birth palsy. Root-SEP is not induced in case of avulsed nerve roots, but is induced in case of both normal and incompletely avulsed roots. Myelography demonstrated 58 abnormal nerve roots in 18 cases (19 limbs); 45 (78%) complete and 13 (22%) incomplete nerve root avulsions. Each of complete and incomplete avulsions was defined as total absence and partial presence of rootlets on myelography, respectively. Traumatic meningoceles were detected at 46 roots (79%) on myelography and/or CTM; 35 roots on myelography and 45 roots on CTM. CTM could not detect only a very small meningocele at one root. At 11 roots CTM was superior to myelography in delineating a meningocele because CTM is sensitive to a poorly enhanced meningocele. CTM, however, could not diagnose nerve root avulsions so accurately as myelography, since myelography detected 12 (7 completely and 5 incompletely) avulsed roots without meningocele, whereas CTM could not delineate the nerve roots clearly. Thus, myelography is indispensable to evaluate nerve root avulsions without meningocele. Root-SEP was examined in 9 patients who underwent branchial plexus exploration. SEP was negative at 22/25 roots with complete avulsion and was positive at 7/7 roots with myelographically incomplete avulsion, regardless of presence or absence of any traumatic meningocele. Myelography and root-SEP correlated well at 29 (92%) out of 32 roots in evaluating complete and incomplete avulsion injuries. Myelography and root-SEP were not considered in 3 roots. Though myelography demonstrated complete avulsions with traumatic meningocele, SEP was positive in these three roots, which were interpreted as partially avulsed roots. (J.P.N.).

  10. Myelography for nerve root avulsion in birth palsy

    International Nuclear Information System (INIS)

    Hashimoto, Tsutomu; Mitomo, Masanori; Hirabuki, Norio; Miura, Takashi; Kawai, Ryuji; Imakita, Satoshi; Harada, Koshi; Nakamura, Hironobu; Kozuka, Takahiro

    1990-01-01

    Myelography and CT myelography (CMT) were reviewed in 18 cases of birth palsy with clinically suspected avulsion injury. Root-somatosensory evoked potential (root-SEP) was also reviewed for myelographic evaluation of the nerve root avolusion in birth palsy. Root-SEP is not induced in case of avulsed nerve roots, but is induced in case of both normal and incompletely avulsed roots. Myelography demonstrated 58 abnormal nerve roots in 18 cases (19 limbs); 45 (78%) complete and 13 (22%) incomplete nerve root avulsions. Each of complete and incomplete avulsions was defined as total absence and partial presence of rootlets on myelography, respectively. Traumatic meningoceles were detected at 46 roots (79%) on myelography and/or CTM; 35 roots on myelography and 45 roots on CTM. CTM could not detect only a very small meningocele at one root. At 11 roots CTM was superior to myelography in delineating a meningocele because CTM is sensitive to a poorly enhanced meningocele. CTM, however, could not diagnose nerve root avulsions so accurately as myelography, since myelography detected 12 (7 completely and 5 incompletely) avulsed roots without meningocele, whereas CTM could not delineate the nerve roots clearly. Thus, myelography is indispensable to evaluate nerve root avulsions without meningocele. Root-SEP was examined in 9 patients who underwent branchial plexus exploration. SEP was negative at 22/25 roots with complete avulsion and was positive at 7/7 roots with myelographically incomplete avulsion, regardless of presence or absence of any traumatic meningocele. Myelography and root-SEP correlated well at 29 (92%) out of 32 roots in evaluating complete and incomplete avulsion injuries. Myelography and root-SEP were not considered in 3 roots. Though myelography demonstrated complete avulsions with traumatic meningocele, SEP was positive in these three roots, which were interpreted as partially avulsed roots. (J.P.N.)

  11. Serial recording of median nerve stimulated subcortical somatosensory evoked potentials (SEPs) in developing brain death.

    Science.gov (United States)

    Buchner, H; Ferbert, A; Hacke, W

    1988-01-01

    Subcortical somatosensory evoked potentials (SEPs) to median nerve stimulation were recorded serially in 35 patients during the evolution towards brain death and in brain death. Neuropathological alterations of the central nervous system down to the C1/C2 spinal cord segment in brain death are well known. SEP components supposed to be generated above this level should be lost in brain death, while components generated below should not be altered. Erb's point, scalp and neck potentials were recorded at C3/4, or over the spinous process C7, using an Fz reference. In 10 patients additional montages, including spinous process C2-Fz, a non-cephalic reference (Fz-contralateral shoulder) and a posterior to anterior neck montage (spinous process C7-jugulum) were used. The cephalic referenced N9 and N11 peaks remained unchanged until brain death. N9 and N11 decreased in parallel in amplitude and increased in latency after systemic effects like hypoxia or hypothermia occurred. The cephalic referenced 'N14' decreased in amplitude and increased in latency after the clinical brain death syndrome was observed, while N13 in the posterior to anterior neck montage remained unchanged. The alteration of 'N14' went parallel to the decrease of the P14 amplitude. The subcortical SEPs in the cephalic referenced lead are supposed to be a peak composed by a horizontally orientated dorsal horn generated N13 and a rostrally orientated P14 arising at the level of the foramen magnum. The deterioration of the non-cephalic referenced P14 and of its cephalic referenced reflection 'N14' seems to provide an additional objective criterion for the diagnosis of brain death.

  12. Nerve excitability in the rat forelimb

    DEFF Research Database (Denmark)

    Arnold, Ria; Moldovan, Mihai; Rosberg, Mette Romer

    2017-01-01

    Background Nerve excitability testing by threshold-tracking is the only available method to study axonal ion channel function and membrane potential in the clinical setting. The measures are, however, indirect and the interpretation of neuropathic changes remains challenging. The same multiple...... measures of axonal excitability were adapted to further explore the pathophysiological changes in rodent disease models under pharmacologic and genetic manipulations. These studies are typically limited to the investigation of the “long nerves” such as the tail or the tibial nerves. New method We introduce...... a novel setup to explore the ulnar nerve excitability in rodents. We provide normative ulnar data in 11 adult female Long Evans rats under anaesthesia by comparison with tibial and caudal nerves. Additionally, these measures were repeated weekly on 3 occasions to determine the repeatability of these tests...

  13. Selective reinnervation: a comparison of recovery following microsuture and conduit nerve repair.

    Science.gov (United States)

    Evans, P J; Bain, J R; Mackinnon, S E; Makino, A P; Hunter, D A

    1991-09-20

    Selective reinnervation was studied by comparing the regeneration across a conventional neurorraphy versus a conduit nerve repair. Lewis rats underwent right sciatic nerve transection followed by one of four different nerve repairs (n = 8/group). In groups I and II a conventional neurorraphy was performed and in groups III and IV the proximal and distal stumps were coapted by use of a silicone conduit with an interstump gap of 5 mm. The proximal and distal stumps in groups I and III were aligned anatomically correct and the proximal stump was rotated 180 degrees in groups II and IV (i.e. proximal peroneal nerve opposite the distal tibial nerve and the proximal tibial nerve opposite the distal peroneal nerve). By 14 weeks, there was an equivalent, but incomplete return in sciatic function index (SFI) in groups I, III, and IV as measured by walking track analysis. However, the SFI became unmeasurable by 6 weeks in all group II animals. At 14 weeks, the percent innervation of the tibialis anterior and medial gastronemius muscles by the peroneal and tibial nerves respectively was estimated by selective compound muscle action potential amplitude recordings. When fascicular alignment was reversed, there was greater tibial (P = 0.02) and lesser peroneal (P = 0.005) innervation of the gastrocnemius muscle in the conduit (group IV) versus the neurorraphy (group II) group. This suggests that the gastrocnemius muscle may be selectively reinnervated by the tibial nerve. However, there was no evidence of selective reinnervation of the tibialis anterior muscle. Despite these differences, the functional recovery in both conduit repair groups (III and IV) was equivalent to a correctly aligned microsuture repair (group I) and superior to that in the incorrectly aligned microsuture repair (group II).

  14. Testing the effectiveness and the contribution of experimental supercharge (reversed) end-to-side nerve transfer.

    Science.gov (United States)

    Nadi, Mustafa; Ramachandran, Sudheesh; Islam, Abir; Forden, Joanne; Guo, Gui Fang; Midha, Rajiv

    2018-05-18

    OBJECTIVE Supercharge end-to-side (SETS) transfer, also referred to as reverse end-to-side transfer, distal to severe nerve compression neuropathy or in-continuity nerve injury is gaining clinical popularity despite questions about its effectiveness. Here, the authors examined SETS distal to experimental neuroma in-continuity (NIC) injuries for efficacy in enhancing neuronal regeneration and functional outcome, and, for the first time, they definitively evaluated the degree of contribution of the native and donor motor neuron pools. METHODS This study was conducted in 2 phases. In phase I, rats (n = 35) were assigned to one of 5 groups for unilateral sciatic nerve surgeries: group 1, tibial NIC with distal peroneal-tibial SETS; group 2, tibial NIC without SETS; group 3, intact tibial and severed peroneal nerves; group 4, tibial transection with SETS; and group 5, severed tibial and peroneal nerves. Recovery was evaluated biweekly using electrophysiology and locomotion tasks. At the phase I end point, after retrograde labeling, the spinal cords were analyzed to assess the degree of neuronal regeneration. In phase II, 20 new animals underwent primary retrograde labeling of the tibial nerve, following which they were assigned to one of the following 3 groups: group 1, group 2, and group 4. Then, secondary retrograde labeling from the tibial nerve was performed at the study end point to quantify the native versus donor regenerated neuronal pool. RESULTS In phase I studies, a significantly increased neuronal regeneration in group 1 (SETS) compared with all other groups was observed, but with modest (nonsignificant) improvement in electrophysiological and behavioral outcomes. In phase II experiments, the authors discovered that secondary labeling in group 1 was predominantly contributed from the donor (peroneal) pool. Double-labeling counts were dramatically higher in group 2 than in group 1, suggestive of hampered regeneration from the native tibial motor neuron pool

  15. Utilização de células-tronco autólogas de medula óssea na regeneração do nervo tibial de coelhos mediante técnica de tubulização com prótese de silicone Applyng of autologous stem cells from bone marrow in the regeneration of tibial nerve of rabbits using the tubulization technique with silicone tube

    Directory of Open Access Journals (Sweden)

    Lucas Marques Colomé

    2008-12-01

    Full Text Available Neste estudo é apresentado um modelo experimental de defeito agudo em nervo periférico para avaliação da regeneração nervosa mediante técnica de tubulização associada à inoculação de células-tronco autólogas de medula óssea. Foram utilizados 12 coelhos Nova Zelândia albinos, submetidos à secção bilateral e ao afastamento de 5mm do nervo tibial e posterior reparo mediante utilização de câmara de silicone. Internamente à prótese de tubulização do nervo tibial esquerdo em todos os animais, foram inoculadas células-tronco autólogas de medula óssea, coletadas a partir do úmero. Como grupo controle (nervo tibial direito, mediante aplicação da mesma técnica de reparo, solução de NaCl 0,9% foi administrada internamente à prótese. Após 30 dias de observação, os animais foram eutanasiados e foi realizada a avaliação histológica dos segmentos nervosos por meio das colorações de hematoxilina-eosina, luxol fast blue e azul de toluidina. Com os resultados, foi possível concluir que o transplante de células-tronco autólogas associado à técnica de tubulização apresenta vantagens no processo de regeneração nervosa periférica.This study presents an experimental model of an acute deffect in a peripheral nerve to evaluate neural regeneration using a tubulization technique associated with the inoculation of autologous stem cells from bone marrow. A total of 12 New Zealand white rabbits underwent a bilateral dissection of the tibial nerve followed by repair with silicone tubulization. On the left tibial nerve of all animals, the tube was filled with autologous bone marrow-derived stem cells collected from the humerus. For control, using the same repair technique, the tubes were filled with a NaCl solution in the right tibial nerve. After 30 days of observation, the animals were euthanized and a histological evaluation of the collected nerve segments was performed by staining with hematoxylin-eosin, luxol fast

  16. Laser-activated solid protein bands for peripheral nerve repair: an vivo study.

    Science.gov (United States)

    Lauto, A; Trickett, R; Malik, R; Dawes, J M; Owen, E R

    1997-01-01

    Severed tibial nerves in rats were repaired using a novel technique, utilizing a semiconductor diode-laser-activated protein solder applied longitudinally across the join. Welding was produced by selective laser denaturation of solid solder bands containing the dye indocyanine green. An in vivo study, using 48 adult male Wistar rats, compared conventional microsuture-repaired tibial nerves with laser solder-repaired nerves. Nerve repairs were characterised immediately after surgery and after 3 months. Successful regeneration with average compound muscle action potentials of 2.5 +/- 0.5 mV and 2.7 +/- 0.3 mV (mean and standard deviation) was demonstrated for the laser-soldered nerves and the sutured nerves, respectively. Histopathology confirmed comparable regeneration of axons in laser- and suture-operated nerves. The laser-based nerve repair technique was easier and faster than microsuture repair, minimising manipulation damage to the nerve.

  17. The clinico-anatomic explanation for tibial intraneural ganglion cysts arising from the superior tibiofibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Spinner, Robert J. [Mayo Clinic, Department of Neurologic Surgery, Rochester, Minnesota (United States); Mayo Clinic, Department of Orthopedic Surgery, Rochester, Minnesota (United States); Mayo Clinic, Department of Anatomy, Rochester, Minnesota (United States); Mokhtarzadeh, Ali; Schiefer, Terry K. [Mayo Clinic College of Medicine, Rochester, Minnesota (United States); Krishnan, Kartik G. [Carl Gustav Carus University Hospital, Department of Neurological Surgery, Dresden (Germany); Kliot, Michel [University of Washington, Department of Neurosurgery, Seattle, Washington (United States); Amrami, Kimberly K. [Mayo Clinic, Department of Radiology, Rochester, Minnesota (United States)

    2007-04-15

    To demonstrate that tibial intraneural ganglia in the popliteal fossa are derived from the posterior portion of the superior tibiofibular joint, in a mechanism similar to that of peroneal intraneural ganglia, which have recently been shown to arise from the anterior portion of the same joint. Retrospective clinical study and prospective anatomic study. The clinical records and MRI findings of three patients with tibial intraneural ganglion cysts were analyzed and compared with those of one patient with a tibial extraneural ganglion cyst and one volunteer. Seven cadaveric limbs were dissected to define the articular anatomy of the posterior aspect of the superior tibiofibular joint. The condition of the three patients with intraneural ganglia recurred because their joint connections were not identified initially. In two patients there was no cyst recurrence when the joint connection was treated at revision surgery; the third patient did not wish to undergo additional surgery. The one patient with an extraneural ganglion had the joint connection identified at initial assessment and had successful surgery addressing the cyst and the joint connection. Retrospective evaluation of the tibial intraneural ganglion cysts revealed stereotypic features, which allowed their accurate diagnosis and distinction from extraneural cases. The intraneural cysts had tubular (rather than globular) appearances. They derived from the postero-inferior portion of the superior tibiofibular joint and followed the expected course of the articular branch on the posterior surface of the popliteus muscle. The cysts then extended intra-epineurially into the parent tibial nerves, where they contained displaced nerve fascicles. The extraneural cyst extrinsically compressed the tibial nerve but did not directly involve it. All cadaveric specimens demonstrated a small single articular branch, which derived from the tibial nerve to the popliteus. The branch coursed obliquely across the posterior

  18. Proximally evoked soleus H-reflex to S1 nerve root stimulation in sensory neuronopathies (ganglionopathies).

    Science.gov (United States)

    Zhu, Dong-Qing; Zhu, Yu; Qiao, Kai; Zheng, Chao-Jun; Bradley, Scott; Weber, Robert; Chen, Xiang-Jun

    2013-11-01

    Sensory neuronopathy (SNN) mimics distal sensory axonopathy. The conventional H-reflex elicited by tibial nerve stimulation (tibial H-reflex) is usually abnormal in both conditions. We evaluated the proximally evoked soleus H-reflex in response to S1 nerve root stimulation (S1 foramen H-reflex) in SNN. Eleven patients with SNN and 6 with distal sensory axonopathy were studied. Tibial and S1 foramen H-reflexes were performed bilaterally in each patient. Tibial and S1 foramen H-reflexes were absent bilaterally in all patients with SNN. In the patients with distal sensory axonopathy, tibial H-reflexes were absent in 4 and demonstrated prolonged latencies in 2, but S1 foramen H-reflexes were normal. Characteristic absence of the H-reflex after both proximal and distal stimulation reflects primary loss of dorsal root ganglion (DRG) neurons and the distinct non-length-dependent impairment of sensory nerve fibers in SNN. Copyright © 2013 Wiley Periodicals, Inc.

  19. Ultrasound-Guided Multiple Peripheral Nerve Blocks in a Superobese Patient

    Directory of Open Access Journals (Sweden)

    Alper Kilicaslan

    2014-01-01

    Full Text Available The number of obese patients has increased dramatically worldwide. Morbid obesity is associated with an increased incidence of medical comorbidities and restricts the application choices in anesthesiology. We report a successfully performed combined ultrasound-guided blockade of the femoral, tibial, and common peroneal nerve in a superobese patient. We present a case report of a 31-year-old, ASA-PS II, super obese man (190 kg, 180 cm, BMI: 58 kg/m2 admitted to the emergency department with a type II segmental tibia shaft fracture and ankle dislocation after a vehicle accident. After two failed spinal anesthesia attempts, we decided to apply a femoral block combined with a sciatic block. Femoral blocks were successfully performed with US guided in-plane technique. Separate blocks of the tibial and common peroneal nerves were planned after the sciatic nerve could not be located due to the thick subcutaneous tissue. We performed a tibial nerve block at 2 cm above the popliteal crease and common peroneal nerve at the level of the fibular head with US guided in-plane technique. The blocks were successful and no block-related complications were noted. Ultrasound guidance allows new approaches for multiple peripheral nerve blocks with low local anesthetic doses in obese patients.

  20. Anatomical Variations in Formation of Sural Nerve in Adult Indian Cadavers

    OpenAIRE

    A.N., Kavyashree; Subhash, Lakshmi Prabha; K.R., Asha; M.K., Bindu Rani

    2013-01-01

    Background: Sural nerve is formed by communication of medial sural cutaneous nerve, that arise from tibial nerve in popliteal fossa and peroneal communicating nerve, a branch directly from common peroneal nerve or from lateral sural cutaneous nerve. The sural nerve is universally recognized by surgeons as a site for harvesting an autologous nerve graft and for nerve biopsies in case of neuropathies.

  1. Free microvascular rotationplasty with nerve repair for rhabdomyosarcoma in a 18-month-old patient.

    Science.gov (United States)

    Pérez-García, Alberto; Salom, Marta; Villaverde-Doménech, María Eloísa; Baixauli, Francisco; Simón-Sanz, Eduardo

    2017-05-01

    Rotationplasty is a limb-sparing surgical option in lower limb malignancies. Sciatic or tibial nerve encasement has been considered an absolute contraindication to this procedure. We report a case of an 18-month-old girl with a rhabdomyosarcoma that affected the leg and popliteal fossa, with neurovascular involvement. Knee and proximal leg intercalary resection was performed followed by reconstruction with free microvascular rotationplasty and neurorraphy from tibial division of sciatic nerve to sural and tibial nerves, and from saphenous nerve to superficial peroneal nerve. Postoperative course was uneventful and ambulation with a provisional prosthesis was restarted during the sixth week after surgery. Bone consolidation was observed after two months. Eighteen months later, the patient had a good gait pattern with a below-knee prosthesis and had recovered sensation in the whole foot and ankle area. This case shows that rotationplasty with nerve repair may provide a sensate stump, which is vital for successful prosthetic adaptation. We believe it may be considered as an alternative to above-knee amputation in tumors with sciatic involvement. © 2017 Wiley Periodicals, Inc.

  2. Differential induction of c-Fos and phosphorylated ERK by a noxious stimulus after peripheral nerve injury.

    Science.gov (United States)

    Tabata, Mitsuyasu; Terayama, Ryuji; Maruhama, Kotaro; Iida, Seiji; Sugimoto, Tomosada

    2018-03-01

    In this study, we compared induction of c-Fos and phosphorylated extracellular signal-regulated kinase (p-ERK) in the spinal dorsal horn after peripheral nerve injury. We examined the spinal dorsal horn for noxious heat-induced c-Fos and p-ERK protein-like immunoreactive (c-Fos- and p-ERK-IR) neuron profiles after tibial nerve injury. The effect of administration of a MEK 1/2 inhibitor (PD98059) on noxious heat-induced c-Fos expression was also examined after tibial nerve injury. A large number of c-Fos- and p-ERK-IR neuron profiles were induced by noxious heat stimulation to the hindpaw in sham-operated animals. A marked reduction in the number of c-Fos- and p-ERK-IR neuron profiles was observed in the medial 1/3 (tibial territory) of the dorsal horn at 3 and 7 days after nerve injury. Although c-Fos-IR neuron profiles had reappeared by 14 days after injury, the number of p-ERK-IR neuron profiles remained decreased in the tibial territory of the superficial dorsal horn. Double immunofluorescence labeling for c-Fos and p-ERK induced by noxious heat stimulation to the hindpaw at different time points revealed that a large number of c-Fos-IR, but not p-ERK-IR, neuron profiles were distributed in the tibial territory after injury. Although administration of a MEK 1/2 inhibitor to the spinal cord suppressed noxious heat-induced c-Fos expression in the peroneal territory, this treatment did not alter c-Fos induction in the tibial territory after nerve injury. ERK phosphorylation may be involved in c-Fos induction in normal nociceptive responses, but not in exaggerated c-Fos induction after nerve injury.

  3. Laser-activated protein solder for peripheral nerve repair

    Science.gov (United States)

    Trickett, Rodney I.; Lauto, Antonio; Dawes, Judith M.; Owen, Earl R.

    1995-05-01

    A 100 micrometers core optical fiber-coupled 75 mW diode laser operating at a wavelength of 800 nm has been used in conjunction with a protein solder to stripe weld severed rat tibial nerves, reducing the long operating time required for microsurgical nerve repair. Welding is produced by selective laser denaturation of the albumin based solder which contains the dye indocyanine green. Operating time for laser soldering was 10 +/- 5 min. (n equals 20) compared to 23 +/- 9 min. (n equals 10) for microsuturing. The laser solder technique resulted in patent welds with a tensile strength of 15 +/- 5 g, while microsutured nerves had a tensile strength of 40 +/- 10 g. Histopathology of the laser soldered nerves, conducted immediately after surgery, displayed solder adhesion to the outer membrane with minimal damage to the inner axons of the nerves. An in vivo study is under way comparing laser solder repaired tibial nerves to conventional microsuture repair. At the time of submission 15 laser soldered nerves and 7 sutured nerves were characterized at 3 months and showed successful regeneration with compound muscle action potentials of 27 +/- 8 mV and 29 +/- 8 mW respectively. A faster, less damaging and long lasting laser based anastomotic technique is presented.

  4. Spontaneous temporal changes and variability of peripheral nerve conduction analyzed using a random effects model

    DEFF Research Database (Denmark)

    Krøigård, Thomas; Gaist, David; Otto, Marit

    2014-01-01

    SUMMARY: The reproducibility of variables commonly included in studies of peripheral nerve conduction in healthy individuals has not previously been analyzed using a random effects regression model. We examined the temporal changes and variability of standard nerve conduction measures in the leg...... reexamined after 2 and 26 weeks. There was no change in the variables except for a minor decrease in sural nerve sensory action potential amplitude and a minor increase in tibial nerve minimal F-wave latency. Reproducibility was best for peroneal nerve distal motor latency and motor conduction velocity......, sural nerve sensory conduction velocity, and tibial nerve minimal F-wave latency. Between-subject variability was greater than within-subject variability. Sample sizes ranging from 21 to 128 would be required to show changes twice the magnitude of the spontaneous changes observed in this study. Nerve...

  5. Superficial or deep implantation of motor nerve after denervation: an experimental study--superficial or deep implantation of motor nerve.

    Science.gov (United States)

    Askar, Ibrahím; Sabuncuoglu, Bízden Tavíl

    2002-01-01

    Neurorraphy, conventional nerve grafting technique, and artificial nerve conduits are not enough for repair in severe injuries of peripheral nerves, especially when there is separation of motor nerve from muscle tissue. In these nerve injuries, reinnervation is indicated for neurotization. The distal end of a peripheral nerve is divided into fascicles and implanted into the aneural zone of target muscle tissue. It is not known how deeply fascicles should be implanted into muscle tissue. A comparative study of superficial and deep implantation of separated motor nerve into muscle tissue is presented in the gastrocnemius muscle of rabbits. In this experimental study, 30 white New Zealand rabbits were used and divided into 3 groups of 10 rabbits each. In the first group (controls, group I), only surgical exposure of the gastrocnemius muscle and motor nerve (tibial nerve) was done without any injury to nerves. In the superficial implantation group (group II), tibial nerves were separated and divided into their own fascicles. These fascicles were implanted superficially into the lateral head of gastrocnemius muscle-aneural zone. In the deep implantation group (group III), the tibial nerves were separated and divided into their own fascicles. These fascicles were implanted around the center of the muscle mass, into the lateral head of the gastrocnemius muscle-aneural zone. Six months later, histopathological changes and functional recovery of the gastrocnemius muscle were investigated. Both experimental groups had less muscular weight than in the control group. It was found that functional recovery was achieved in both experimental groups, and was better in the superficial implantation group than the deep implantation group. EMG recordings revealed that polyphasic and late potentials were frequently seen in both experimental groups. Degeneration and regeneration of myofibrils were observed in both experimental groups. New motor end-plates were formed in a scattered

  6. Functional recovery of denervated skeletal muscle with sensory or mixed nerve protection: a pilot study.

    Directory of Open Access Journals (Sweden)

    Qing Tian Li

    Full Text Available Functional recovery is usually poor following peripheral nerve injury when reinnervation is delayed. Early innervation by sensory nerve has been indicated to prevent atrophy of the denervated muscle. It is hypothesized that early protection with sensory axons is adequate to improve functional recovery of skeletal muscle following prolonged denervation of mixed nerve injury. In this study, four groups of rats received surgical denervation of the tibial nerve. The proximal and distal stumps of the tibial nerve were ligated in all animals except for those in the immediate repair group. The experimental groups underwent denervation with nerve protection of peroneal nerve (mixed protection or sural nerve (sensory protection. The experimental and unprotected groups had a stage II surgery in which the trimmed proximal and distal tibial nerve stumps were sutured together. After 3 months of recovery, electrophysiological, histological and morphometric parameters were assessed. It was detected that the significant muscle atrophy and a good preserved structure of the muscle were observed in the unprotected and protective experimental groups, respectively. Significantly fewer numbers of regenerated myelinated axons were observed in the sensory-protected group. Enhanced recovery in the mixed protection group was indicated by the results of the muscle contraction force tests, regenerated myelinated fiber, and the results of the histological analysis. Our results suggest that early axons protection by mixed nerve may complement sensory axons which are required for promoting functional recovery of the denervated muscle natively innervated by mixed nerve.

  7. Anastomotic stoma coated with chitosan film as a betamethasone dipropionate carrier for peripheral nerve regeneration

    Directory of Open Access Journals (Sweden)

    Ping Yao

    2018-01-01

    Full Text Available Scar hyperplasia at the suture site is an important reason for hindering the repair effect of peripheral nerve injury anastomosis. To address this issue, two repair methods are often used. Biological agents are used to block nerve sutures and the surrounding tissue to achieve physical anti-adhesion effects. Another agent is glucocorticosteroid, which can prevent scar growth by inhibiting inflammation. However, the overall effect of promoting regeneration of the injured nerve is not satisfactory. In this regard, we envision that these two methods can be combined and lead to shared understanding for achieving improved nerve repair. In this study, the right tibial nerve was transected 1 cm above the knee to establish a rat tibial nerve injury model. The incision was directly sutured after nerve transection. The anastomotic stoma was coated with 0.5 × 0.5 cm2 chitosan sheets with betamethasone dipropionate. At 12 weeks after injury, compared with the control and poly (D, L-lactic acid groups, chitosan-betamethasone dipropionate film slowly degraded with the shape of the membrane still intact. Further, scar hyperplasia and the degree of adhesion at anastomotic stoma were obviously reduced, while the regenerated nerve fiber structure was complete and arranged in a good order in model rats. Electrophysiological study showed enhanced compound muscle action potential. Our results confirm that chitosan-betamethasone dipropionate film can effectively prevent local scar hyperplasia after tibial nerve repair and promote nerve regeneration.

  8. Electrophysiological Evaluation of People With Volatile Substance Addiction

    Directory of Open Access Journals (Sweden)

    Nurten Uzun

    2008-02-01

    Full Text Available OBJECTIVE: Scientific BACKGROUND: There is an increase in addiction of volatile substances in recent years. Miscellaneous electrophysiological pathological findings are determined in volatile substance abusers. OBJECTIVE: In this study, we aim to examine the neurologic effects of these substances by electrophysiologic methods. METHODS: Cases and METHOD: Twenty-three patients from Bakirkoy Psychiatry Hospital, Alcohol and Substance Addiction Research and Treatment Center were included in this study. Motor and sensory nerve conduction studies, somatosensorial, visual and auditory evoked potentials (SEP, VEP, BAEP as well as electroencephalography (EEG were studied in all 23 patients. The results were compared with the published data and the values of age matched 19 normal controls. RESULTS: RESULTS: In nerve conduction studies, there were pathological findings in 14 (60.9% cases, in three (13% mild sensorimotor polyneuropathy was determined. Tibial nerve motor distal latencies as well as median nerve sensorial and sural nerve distal latencies were longer in patients compared to controls (p<0.05. SEP findings were pathological in six (26.1% cases, VEP in two (8.7% cases and BAEP in eight (34.8% cases. Scalp SEP distal latency by tibial nerve stimulation as well as distal latencies of right and left V. wave, left III-V interpeak latency, right and left interpeak latencies and I-V interaural latency difference in BAEP were longer in abusers (p<0.05. Although it was not statistically significant, the ratio of pathological findings was higher if the exposure time was over 2 years. EEG was found to be normal in all patients. CONCLUSION: YORUM: Our results showed that toluene results in slowly progressive multifocal central nervous system damage and subclinical damage could be determined in early stages by electrophysiologic methods

  9. Nerve transection repair using laser-activated chitosan in a rat model.

    Science.gov (United States)

    Bhatt, Neel K; Khan, Taleef R; Mejias, Christopher; Paniello, Randal C

    2017-08-01

    Cranial nerve transection during head and neck surgery is conventionally repaired with microsuture. Previous studies have demonstrated recovery with laser nerve welding (LNW), a novel alternative to microsuture. LNW has been reported to have poorer tensile strength, however. Laser-activated chitosan, an adhesive biopolymer, may promote nerve recovery while enhancing the tensile strength of the repair. Using a rat posterior tibial nerve injury model, we compared four different methods of nerve repair in this pilot study. Animal study. Animals underwent unilateral posterior tibial nerve transection. The injury was repaired by potassium titanyl phosphate (KTP) laser alone (n = 20), KTP + chitosan (n = 12), microsuture + chitosan (n = 12), and chitosan alone (n = 14). Weekly walking tracks were conducted to measure functional recovery (FR). Tensile strength (TS) was measured at 6 weeks. At 6 weeks, KTP laser alone had the best recovery (FR = 93.4% ± 8.3%). Microsuture + chitosan, KTP + chitosan, and chitosan alone all showed good FR (87.4% ± 13.5%, 84.6% ± 13.0%, and 84.1% ± 10.0%, respectively). One-way analysis of variance was performed (F(3,56) = 2.6, P = .061). A TS threshold of 3.8 N was selected as a control mean recovery. Three groups-KTP alone, KTP + chitosan, and microsuture + chitosan-were found to meet threshold 60% (95% confidence interval [CI]: 23.1%-88.3%), 75% (95% CI: 46.8%-91.1%), and 100% (95% CI: 75.8%-100.0%), respectively. In the posterior tibial nerve model, all repair methods promoted nerve recovery. Laser-activated chitosan as a biopolymer anchor provided good TS and appears to be a novel alternative to microsuture. This repair method may have surgical utility following cranial nerve injury during head and neck surgery. NA Laryngoscope, 127:E253-E257, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  10. Comparison of the fastest regenerating motor and sensory myelinated axons in the same peripheral nerve

    DEFF Research Database (Denmark)

    Moldovan, Mihai; Sørensen, Jesper; Krarup, Christian

    2006-01-01

    Functional outcome after peripheral nerve regeneration is often poor, particularly involving nerve injuries far from their targets. Comparison of sensory and motor axon regeneration before target reinnervation is not possible in the clinical setting, and previous experimental studies addressing...... the question of differences in growth rates of different nerve fibre populations led to conflicting results. We developed an animal model to compare growth and maturation of the fastest growing sensory and motor fibres within the same mixed nerve after Wallerian degeneration. Regeneration of cat tibial nerve...... after crush (n = 13) and section (n = 7) was monitored for up to 140 days, using implanted cuff electrodes placed around the sciatic and tibial nerves and wire electrodes at plantar muscles. To distinguish between sensory and motor fibres, recordings were carried out from L6-S2 spinal roots using cuff...

  11. Regeneration of peripheral nerve fibres following Haloxon-induced degeneration

    Directory of Open Access Journals (Sweden)

    Maria Veronica de Souza

    1996-12-01

    Full Text Available Delayed neurotoxicity has been associated with organophosphorus poisoning for years. In order to study such condition in sheep, 11 animals were given either one or two high doses of Haloxon. Exposed sheep were observed daily and between 16 and 25 days after administration neurological signs as incoordination and ataxia were detected in six of them. Biopsies of tibial and laryngeal nerves were performed as soon as neurotoxicity was diagnosed, and after death fragments of selected nerves were collected together with CNS tissues for light and electron microscopy and teased fiber studies. Laryngeal, tibial and sciatic nerves showed the most pronouced changes, consisting chiefly of wallerian degeneration that was seen either as a single fiber or as a complete fascicle feature. Exams performed after death clearly showed regenerating fascicles with axonal sprouts growing within a Schwann cell old basal lamina, and some thinly myelinated axonal sprouts.

  12. Laser-activated protein bands for peripheral nerve repair

    Science.gov (United States)

    Lauto, Antonio; Trickett, Rodney I.; Malik, Richard; Dawes, Judith M.; Owen, Earl R.

    1996-01-01

    A 100 micrometer core optical fiber-coupled 75 mW diode laser operating at a wavelength of 800 nm has been used in conjunction with a protein solder to stripe weld severed rat tibial nerves, reducing the long operating time required for microsurgical nerve repair. Welding is produced by selective laser denaturation of the protein based solder which contains the dye indocyanine green. Operating time for laser soldering was 10 plus or minus 5 min. (n equals 24) compared to 23 plus or minus 9 min (n equals 13) for microsuturing. The laser solder technique resulted in patent welds with a tensile strength of 15 plus or minus 5 g, while microsutured nerves had a tensile strength of 40 plus or minus 10 g. Histopathology of the laser soldered nerves, conducted immediately after surgery, displayed solder adhesion to the outer membrane with minimal damage to the inner axons of the nerves. An in vivo study, with a total of fifty-seven adult male wistar rats, compared laser solder repaired tibial nerves to conventional microsuture repair. Twenty-four laser soldered nerves and thirteen sutured nerves were characterized at three months and showed successful regeneration with average compound muscle action potentials (CMAP) of 2.4 plus or minus 0.7 mV and 2.7 plus or minus 0.8 mV respectively. Histopathology of the in vivo study, confirmed the comparable regeneration of axons in laser and suture operated nerves. A faster, less damaging and long lasting laser based anastomotic technique is presented.

  13. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  14. Imaging of the nerves of the knee region

    Energy Technology Data Exchange (ETDEWEB)

    Damarey, B., E-mail: benjdam@hotmail.com [Service de Radiologie et d’Imagerie musculosquelettique, CCIAL, Hôpital Roger Salengro, CHRU de Lille, Rue Emile Laine, 59037 Lille Cedex (France); Laboratoire d’anatomie, Faculté de médecine, CHRU de Lille, 1 Place de Verdun, 59045 Lille Cedex (France); Demondion, X. [Service de Radiologie et d’Imagerie musculosquelettique, CCIAL, Hôpital Roger Salengro, CHRU de Lille, Rue Emile Laine, 59037 Lille Cedex (France); Laboratoire d’anatomie, Faculté de médecine, CHRU de Lille, 1 Place de Verdun, 59045 Lille Cedex (France); Wavreille, G. [Laboratoire d’anatomie, Faculté de médecine, CHRU de Lille, 1 Place de Verdun, 59045 Lille Cedex (France); Service d’orthopédie, Hôpital Roger Salengro, CHRU de Lille, Rue Emile Laine, 59037 Lille Cedex (France); Pansini, V.; Balbi, V.; Cotten, A. [Service de Radiologie et d’Imagerie musculosquelettique, CCIAL, Hôpital Roger Salengro, CHRU de Lille, Rue Emile Laine, 59037 Lille Cedex (France)

    2013-01-15

    Peripheral neuropathies are a frequent, but often underdiagnosed, cause of pain and functional impairment. The clinical symptoms can be subtle, and other neurologic or non neurologic clinical entities are often evoked. MRI and ultrasonography are the imaging modalities of choice for depicting nerves and assessing neuropathies. Common neuropathies in the knee area involve the saphenous, the tibial, the common peroneal and the sural nerves. The most frequent mechanisms of nerve injury in this area are nerve entrapment and nerve stretching. A perfect knowledge of the normal imaging anatomy is essential for accurate assessment of neuropathies. In this article, we will review the anatomy of the nerves around the knee, and their normal and pathological appearance.

  15. Imaging of the nerves of the knee region

    International Nuclear Information System (INIS)

    Damarey, B.; Demondion, X.; Wavreille, G.; Pansini, V.; Balbi, V.; Cotten, A.

    2013-01-01

    Peripheral neuropathies are a frequent, but often underdiagnosed, cause of pain and functional impairment. The clinical symptoms can be subtle, and other neurologic or non neurologic clinical entities are often evoked. MRI and ultrasonography are the imaging modalities of choice for depicting nerves and assessing neuropathies. Common neuropathies in the knee area involve the saphenous, the tibial, the common peroneal and the sural nerves. The most frequent mechanisms of nerve injury in this area are nerve entrapment and nerve stretching. A perfect knowledge of the normal imaging anatomy is essential for accurate assessment of neuropathies. In this article, we will review the anatomy of the nerves around the knee, and their normal and pathological appearance

  16. Estimation of ultrasound reference values for the lower limb peripheral nerves in adults: A cross-sectional study.

    Science.gov (United States)

    Bedewi, Mohamed Abdelmohsen; Abodonya, Ahmed; Kotb, Mamdouh; Kamal, Sanaa; Mahmoud, Gehan; Aldossari, Khaled; Alqabbani, Abdullah; Swify, Sherine

    2018-03-01

    The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ± 6.9, tibial nerve at the level of the medial malleolus 12.7 mm ± 4.5, common peroneal nerve at the popliteal fossa 9.5 mm ± 4, common peroneal nerve fibular head 8.9 mm ± 3.2, sural nerve 3.5 mm ± 1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.

  17. Nerve Cross-Bridging to Enhance Nerve Regeneration in a Rat Model of Delayed Nerve Repair

    Science.gov (United States)

    2015-01-01

    There are currently no available options to promote nerve regeneration through chronically denervated distal nerve stumps. Here we used a rat model of delayed nerve repair asking of prior insertion of side-to-side cross-bridges between a donor tibial (TIB) nerve and a recipient denervated common peroneal (CP) nerve stump ameliorates poor nerve regeneration. First, numbers of retrogradely-labelled TIB neurons that grew axons into the nerve stump within three months, increased with the size of the perineurial windows opened in the TIB and CP nerves. Equal numbers of donor TIB axons regenerated into CP stumps either side of the cross-bridges, not being affected by target neurotrophic effects, or by removing the perineurium to insert 5-9 cross-bridges. Second, CP nerve stumps were coapted three months after inserting 0-9 cross-bridges and the number of 1) CP neurons that regenerated their axons within three months or 2) CP motor nerves that reinnervated the extensor digitorum longus (EDL) muscle within five months was determined by counting and motor unit number estimation (MUNE), respectively. We found that three but not more cross-bridges promoted the regeneration of axons and reinnervation of EDL muscle by all the CP motoneurons as compared to only 33% regenerating their axons when no cross-bridges were inserted. The same 3-fold increase in sensory nerve regeneration was found. In conclusion, side-to-side cross-bridges ameliorate poor regeneration after delayed nerve repair possibly by sustaining the growth-permissive state of denervated nerve stumps. Such autografts may be used in human repair surgery to improve outcomes after unavoidable delays. PMID:26016986

  18. Sep diagnosing neurophaty of the lateral cutaneous branch of the iliohypogastric nerve: case report Neuropatia do ramo cutâneo lateral do nervo ílio-hipogástrico diagnosticada por PES: relato de caso

    Directory of Open Access Journals (Sweden)

    Rafael José Soares Dias

    2004-09-01

    Full Text Available The article pertains to the uncommon clinical case of a patient with a proximal neuropathy of the lower extremity. It outlines the electrophysiological evaluation and reviews the medical literature. The electrophysiologic test that most accurately revealed the neuropathy was the segmental somatosensory evoked potential (SEP of the lateral cutaneous branch of the iliohypogastric nerve. It showed well-defined and replicable cortical waveforms following the excitation of the lateral cutaneous branch of the iliohypogastric nerve in the asymptomatic lower extremity, but failed to present somatosensory evoked potentials arising from the excitation of the contralateral nerve in the symptomatic lower extremity. We did not find any previous reports diagnosing that particular pathology by the use of segmental SEP. In conclusion, it is important to remember that the accurate diagnosis of patients complaining of pain and dysesthesia in the proximal part of the lower extremities can possibly be achieved through the use of electrophysiologic tests such as the segmental SEP.O presente artigo relata caso clínico incomum de neuropatia proximal de membro inferior, demonstra eletrofisiologicamente o comprometimento neural e revisa a literatura médica sobre o assunto. O teste neurofisiológico que demonstrou a patologia foi o potencial evocado somato-sensitivo (PES segmentar do ramo cutâneo lateral do nervo ílio-hipogástrico. Ele revelou potenciais corticais bem definidos e replicáveis à estimulação do membro inferior assintomático, mas falhou em produzir respostas corticais do membro inferior sintomático. Na revisão da literatura não foi encontrado nenhum relato anterior de diagnóstico dessa patologia por PES segmentar. Conclui-se que é importante ter em mente ao avaliar pacientes com queixas de dor e disestesia na base dos membros inferiores que o acometimento de pequenos ramos cutâneos, como o cutâneo lateral do ílio-hipogástrico, pode ter

  19. Autologous mononuclear bone marrow cells in the regeneration of tibial nerve of rabbits submitted to neurectomy: morphofunctional aspectsCélulas mononucleares autólogas de medula óssea na regeneração do nervo tibial de coelhos submetidos à neurectomia: aspectos morfofuncionais

    Directory of Open Access Journals (Sweden)

    Camila França de Paula Orlando-Goulart

    2013-10-01

    Full Text Available The functional recovery after peripheral nerve injury is the main goal of therapeutic intervention. Therefore the aim of this study was to clinically evaluate functional recovery in rabbits after neurectomy and treatment with bone marrow mononuclear cells associated with the tubulization technique. For this, 24 New Zealand rabbits, were used. They were divided into two groups with 12 animals each, mononuclear cell group (MCG and saline group (SSG. The rabbits underwent right tibial nerve section and repair by the tubulization technique using silicone hollow tube, which received 0.1 ml of autologous mononuclear bone marrow cells (2 x 106 cells in the MCG and of saline solution in the SSG, in order to compare the evolution of functional recovery of the operated limbs. Gait and planimetry were performed. Planimetry of the pelvic limb footprint printed on paper with water-based ink applied to the plantar area, before (M0 and after 7 (M7, 15 (M15, 30 (M30, 45 (M45 and 60 (M60 days after surgery. The results showed no functional recovery of the tibial nerve in both groups, without differences between them in different times and among times within groups, except when compared to M0.A recuperação funcional de nervos periféricos após lesão é o principal objetivo da intervenção terapêutica. Por isso o objetivo deste estudo foi avaliar clinicamente a recuperação funcional de coelhos após neurectomia e tratamento com células mononucleares de medula óssea associada à técnica de tubulização. Foram utilizados para isto, 24 coelhos da raça Nova Zelândia, alocados em dois grupos com 12 animais cada, denominados grupo célula mononuclear (GCM e grupo solução salina (GSS. Os coelhos foram submetidos à secção do nervo tibial direito e reparação por meio da técnica de tubulização utilizando tubo oco de silicone, para então, receberem no interior do tubo, 0,1mL de suspensão de células mononucleares autólogas de medula óssea (2 x 106

  20. Anatomical aspects of the nerves of the leg and foot of the giant anteater (Myrmecophaga tridactyla, Linnaeus, 1758

    Directory of Open Access Journals (Sweden)

    V.S. Cruz

    2014-10-01

    Full Text Available Although distal stifle joint nerve distribution has been well established in domestic animals, this approach is scarcely reported in wild animals. Therefore, the aim of this study was to describe the nerves of the leg and foot of Myrmecophaga tridactyla with emphasis on their ramification, distribution, topography and territory of innervation. For this purpose, six adult cadavers fixed and preserved in 10% formalin solution were used. The nerves of the leg and foot of the M. tridactyla were the saphenous nerve (femoral nerve branch, fibular and tibial nerves and lateral sural cutaneous nerve (branches of the sciatic nerve and caudal sural cutaneous nerve (tibial nerve branch. The saphenous nerve branches to the skin, the craniomedial surface of the leg, the medial surface of the tarsal and metatarsal regions and the dorsomedial surface of the digits I and II (100% of cases, III (50% of cases and IV (25% of cases. The lateral sural cutaneous nerve innervates the skin of the craniolateral region of the knee and leg. The fibular nerve innervates the flexor and extensor muscles of the tarsal region of the digits and skin of the craniolateral surface of the leg and dorsolateral surface of the foot. The tibial nerve innervates the extensor muscles of the tarsal joint and flexor, adductor and abductor muscles of the digits and the skin of the plantar surface. The caudal sural cutaneous nerve innervates the skin of the caudal surface of the leg. The nerves responsible for the leg and foot innervation were the same as reported in domestic and wild animals, but with some differences, such as the more distal division of the common fibular nerve, the absence of dorsal metatarsal branches of the deep fibular nerve and a greater involvement of the saphenous nerve in the digital innervation with branches to the digits III and IV, in addition to digits I and II.

  1. Changes in the EEG and SEP of patients with cerebrovascular major strokes

    International Nuclear Information System (INIS)

    Iwayama, Kaoru; Tanaka, Keisei; Yamashiro, Katsumi; Mori, Kazuo

    1980-01-01

    Changes in the electroencephalogram (EEG) and somatosensory evoked potential (SEP) were studied in 27 cases with unilateral cerebrovascular disorders. From the CT findings (EMI-1010), the locations of the diseases were divided into two types: superficial (within the cortex and subcortical white matter) or deep (at the level of the basal ganglia and thalamus). Each of these was then further subdivided according to the nature of the disease, whether hemorrhage or infarction. The EEG and SEP were recorded from the scalp area corresponding to the post-Rolandic arm area (Shagass' point) throughout the investigation. The stimulus intensities applied to the median nerve were fixed at 5 - 10 V. higher than the motor threshold. EEG power spectrum analysis was done with an ATAC 2300 computer, while slow-wave indices (SWI), the ratio of power in the slow-wave range (2 - 6 Hz) to the total power (2 - 25 Hz), were calculated manually. In deep lesions, the deterioration of the SEP was prominent. Especially in the 5 cases with bleeding, all 5 showed a ''flat SEP.'' These patients also revealed motor and sensory disturbance clinically. In the 6 cases with infarction, although no one showed sensory disturbances, the changes in the SEP were also remarkable. In deep lesions, a decrease in the amplitude of the early components of SEP (N 1 , P 1 ) was the most conspicuous feature. On the contrary, in superficial lesions, changes in the SEP were less prominent, and if they occurred, the late components (P 2 , N 3 ) were more easily affected. The amount of the slow wave increased remarkably and bilaterally in these superficial cases, and the slower the frequency of the EEG, the more attenuation of the amplitude of SEP was noted on the lesion side. On the opposite side, however, no such correlations could be noted between an increased slow-wave power and a decreased amplitude of SEP. Further studies to clarify these differences will be necessary. (author)

  2. Combined application of neutrophin-3 gene and neural stem cells is ameliorative to delay of denervated skeletal muscular atrophy after tibial nerve transection in rats.

    Science.gov (United States)

    Lin, Sen; Xu, Jianguang; Hu, Shaonan; Xu, Lei; Zhang, Changqing; Wang, Yang; Gu, Yudong

    2011-01-01

    Examination of the therapeutic efficacy of neural stem cells (NSCs) has recently become the focus of much investigation. In this study we present an insight of the effects of combined application with neurotrophin-3 (NT-3) and NSCs that derived from rat embryo spinal cord on delaying denervated skeletal muscular atrophy after tibial nerve was severed. NT-3 gene was amplified by PCR and subcloned into lentiviral vector pWPXL-MOD to construct a lentiviral expression vector pWPXL-MOD-NT-3. A positive clone expressing NT-3 (named NSCs-NT-3) was obtained and used for differentiation in vitro and transplantation. Sixty adult rats, whose tibial nerves were sectioned, were divided into two groups: one grafted with NSCs-NT-3 (experimental group, n = 30) and the other with NSCs transfected by pWPXL-MOD (control group, n = 30). The cell survival and differentiation, NT-3 gene expression, and effect of delaying denervated skeletal muscular atrophy were examined through immunohistostaining, RT-PCR, Western blot, electrophysiological analysis, and mean cross-sectional area (CSA) of gastrocnemius, respectively. The results show that the NT-3 gene, which is comprised of 777 bp, was cloned and significantly different expression were detected between NSCs and NSCs-NT-3 in vitro. Quantitative analysis of the choline acetyltransferase (ChAT) immunopositive cells revealed a significant increase in experimental group compared to the control group 4 weeks after implantation (p ChAT immunopositive cells were detected near the engrafted region only in experimental group. Furthermore, the effect in delaying denervated skeletal muscular atrophy is indicated in the EMG examination and mean CSA of gastrocnemius. These findings suggest that the neural stem cells expressing NT-3 endogenously would be a better graft candidate for the delay of denervated skeletal muscular atrophy.

  3. Acceleration of Regeneration of Large Gap Peripheral Nerve Injuries Using Acellular Nerve Allografts plus amniotic Fluid Derived Stem Cells (AFS)

    Science.gov (United States)

    2016-09-01

    AWARD NUMBER: W811XWH-13-1-0310 TITLE: Acceleration of Regeneration of Large-Gap Peripheral Nerve Injuries Using Acellular Nerve Allografts...plus amniotic Fluid Derived Stem Cells (AFS). PRINCIPAL INVESTIGATOR: Zhongyu Li, MD, PhD RECIPIENT: Wake Forest University Health Sciences...REPORT DATE September 2016 2. REPORT TYPE Annual 3. DATES COVERED 1Sep2015 - 31Aug2016 4. TITLE AND SUBTITLE Acceleration of Regeneration of Large

  4. Anthropometric measurements of tibial plateau and correlation with the current tibial implants.

    Science.gov (United States)

    Erkocak, Omer Faruk; Kucukdurmaz, Fatih; Sayar, Safak; Erdil, Mehmet Emin; Ceylan, Hasan Huseyin; Tuncay, Ibrahim

    2016-09-01

    The aim of the study was to make an anthropometric analysis at the resected surfaces of the proximal tibia in the Turkish population and to compare the data with the dimensions of tibial components in current use. We hypothesized that tibial components currently available on the market do not fulfil the requirements of this population and a new tibial component design may be required, especially for female patients with small stature. Anthropometric data from the proximal tibia of 226 knees in 226 Turkish subjects were measured using magnetic resonance imaging. We measured the mediolateral, middle anteroposterior, medial and lateral anteroposterior dimensions and the aspect ratio of the resected proximal tibial surface. All morphological data were compared with the dimensions of five contemporary tibial implants, including asymmetric and symmetric design types. The dimensions of the tibial plateau of Turkish knees demonstrated significant differences according to gender (P < 0.05). Among the different tibial implants reviewed, neither asymmetric nor symmetric designs exhibited a perfect conformity to proximal tibial morphology in size and shape. The vast majority of tibial implants involved in this study tend to overhang anteroposteriorly, and a statistically significant number of women (21 %, P < 0.05) had tibial anteroposterior diameters smaller than the smallest available tibial component. Tibial components designed according to anthropometric measurements of Western populations do not perfectly meet the requirements of Turkish population. These data could provide the basis for designing the optimal and smaller tibial component for this population, especially for women, is required for best fit. II.

  5. Estudo da regeneração de nervos tibiais de ratos Wistar em sutura primária com "gap" e sem "gap", cobertos por segmentos de veia Study of tibial nerve regenration in Wistar rats in primary neurorrhaphy with and without gap, wrapped in vein segments

    Directory of Open Access Journals (Sweden)

    Ewerton Bastos dos Santos

    2012-01-01

    Full Text Available OBJETIVO: O presente estudo comparou, em ratos da raça Wistar, a regeneração nervosa nas suturas epineurais com espaçamento de 1,0mm (com "gap" e sem espaçamento (sem "gap", ambos cobertos com tubo de veia jugular externa, através da contagem de motoneurônios no nível da medula espinhal entre L3 e S1, marcados por meio de exposição do nervo tibial ao Fluoro - Goldâ (FG. MÉTODO: Os nervos tibias de ambos os lados foram seccionados e foram realizadas suturas epineurais com "gap" e, no lado contralateral, sem "gap" sendo que as suturas foram cobertas com tubo de veia. Após quatro meses do procedimento cirúrgico, os nervos tibias foram expostos ao FG, perfundidos e realizada a contagem dos motoneurônios na medula espinhal. RESULTADOS: Para a análise estatística foi utilizado o teste de Wilcoxon pareado, onde obtivemos um resultado estatisticamente significante entre o número de motoneurônios do grupo com "gap" em relação ao sem "gap" (p= 0,013. CONCLUSÃO: Obtivemos melhores resultados na contagem de motoneurônios daqueles nervos onde haviam sido realizadas as suturas primárias sem "gap", quando comparados com as suturas com "gap". Nível de Evidência: Estudo Experimental.OBJECTIVE: This study compared nerve regeneration in Wistar rats, using epineural neurorrhaphy with a gap of 1.0 mm and without a gap, both wrapped with jugular vein tubes. Motor neurons in the spinal cord between L3 and S1 were used for the count, marked by exposure of the tibial nerve to Fluoro-Gold (FG. METHOD: The tibial nerves on both sides were cut and sutured, with a gap on one side and no gap in the other. The sutures were wrapped with a jugular vein. Four months after surgery the tibial nerves were exposed to Fluoro-Gold and the motor neuron count performed in the spinal cord. RESULTS: The results were statistically analyzed by the paired Wilcoxon test. There was a statistical difference between the groups with and without gap in relation to the

  6. Low- and high-frequency subcortical SEP amplitude reduction during pure passive movement.

    Science.gov (United States)

    Insola, Angelo; Padua, Luca; Mazzone, Paolo; Valeriani, Massimiliano

    2015-12-01

    To investigate the effect of pure passive movement on both cortical and subcortical somatosensory evoked potentials (SEPs). Median nerve SEPs were recorded in 8 patients suffering from Parkinson's disease (PD) and two patients with essential tremor. PD patients underwent electrode implantation in the subthalamic (STN) nucleus (3 patients) and pedunculopontine (PPTg) nucleus (5 patients), while 2 patients with essential tremor were implanted in the ventral intermediate nucleus (VIM) of the thalamus. In anesthetized patients, SEPs were recorded at rest and during a passive movement of the thumb of the stimulated wrist from the intracranial electrode contacts and from the scalp. Also the high-frequency oscillations (HFOs) were analyzed. Amplitudes of both deep and scalp components were decreased during passive movement, but the reduction was higher at cortical than subcortical level. Also the HFOs were reduced by movement. The different amount of the movement-related decrease suggests that the cortical SEP gating is not only the result of a subcortical somatosensory volley attenuation, but a further mechanism acting at cortical level should be considered. Our results are important for understanding the physiological mechanism of the sensory-motor interaction during passive movement. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Intraexaminer and interexaminer reliability of manual palpation and pressure algometry of the lower limb nerves in asymptomatic subjects.

    LENUS (Irish Health Repository)

    Fingleton, Caitriona P

    2014-02-01

    Nerve palpation is a method of clinically identifying mechanosensitivity of neural tissue by means of pressure algometry and manual palpation. There are few investigations of the reliability of lower limb nerve palpation, and femoral nerve palpation has never been previously reported. The aim of this study was to investigate the reliability of nerve palpation of the femoral, sciatic, tibial, and common peroneal nerves and to report normative values for the femoral nerve.

  8. Medial tibial “spackling” to lessen chronic medial tibial soft tissue irritation

    Directory of Open Access Journals (Sweden)

    J. Ryan Martin, MD

    2016-09-01

    Full Text Available We describe a unique, utilitarian reconstructive treatment option known as tibial “spackling” for chronic, localized medial joint line pain corresponding with progressive radiographic peripheral medial tibial bone loss beneath a well-fixed revision total knee arthroplasty tibial baseplate. It is believed that this localized pain is due to chronic irritation of the medial capsule and collateral ligament from the prominent medial edge of the tibial component. In the setting of failed nonoperative treatment, our experience with utilizing bone cement to reconstruct the medial tibial bone defect and create a smooth medial tibial surface has been successful in eliminating chronic medial soft tissue irritation.

  9. Comparison of nerve conduction and injury degree in patients with lumbar disc herniation after microendoscopic discectomy and fenestration discectomy

    Directory of Open Access Journals (Sweden)

    Jun Li

    2017-09-01

    Full Text Available Objective: To study the difference of nerve conduction and injury degree in patients with lumbar disc herniation after microendoscopic discectomy and fenestration discectomy. Methods: Patients with single-segment lumbar disc herniation who were treated in Dazhou Central Hospital between May 2014 and February 2017 were selected as the research subjects, the history data were reviewed and the operation methods were referred to divide them into FD group and MED group who received fenestration discectomy and microendoscopic discectomy respectively. The conduction velocity of common peroneal nerve and tibial nerve were detected before operation and 4 weeks after operation; serum levels of nerve and muscle injury-related molecules as well as inflammation and stress-related molecules were detected before operation and 3 days after operation. Results: MNCV levels of common peroneal nerve and tibial nerve 4 weeks after operation as well as serum CRP, TNF-α, MDA and AOPP contents 3 d after operation of both groups of patients were significantly higher than those before operation, and the MNCV levels of common peroneal nerve and tibial nerve of MED group 4 weeks after operation were significantly higher than those of FD group while serum CRP, TNF-α, MDA and AOPP contents of MED group 3 d after operation were not significantly different from those of FD group; serum NSE, S100B, Tau, pNF-H, CPK, Myo and LDH contents of FD patients 3 d after operation were significantly higher than those before operation while serum NSE, S100B, Tau, pNF-H, CPK, Myo and LDH contents of MED group were not significantly different from those before operation. Conclusion: Microendoscopic discectomy for lumbar disc herniation can relieve the nerve and muscle injury, and is equivalent to fenestration discectomy in activating the systemic stress and inflammatory response.

  10. Dynamic SEP event probability forecasts

    Science.gov (United States)

    Kahler, S. W.; Ling, A.

    2015-10-01

    The forecasting of solar energetic particle (SEP) event probabilities at Earth has been based primarily on the estimates of magnetic free energy in active regions and on the observations of peak fluxes and fluences of large (≥ M2) solar X-ray flares. These forecasts are typically issued for the next 24 h or with no definite expiration time, which can be deficient for time-critical operations when no SEP event appears following a large X-ray flare. It is therefore important to decrease the event probability forecast with time as a SEP event fails to appear. We use the NOAA listing of major (≥10 pfu) SEP events from 1976 to 2014 to plot the delay times from X-ray peaks to SEP threshold onsets as a function of solar source longitude. An algorithm is derived to decrease the SEP event probabilities with time when no event is observed to reach the 10 pfu threshold. In addition, we use known SEP event size distributions to modify probability forecasts when SEP intensity increases occur below the 10 pfu event threshold. An algorithm to provide a dynamic SEP event forecast, Pd, for both situations of SEP intensities following a large flare is derived.

  11. MRI of peripheral nerve lesions of the lower limbs

    Energy Technology Data Exchange (ETDEWEB)

    Lacour-Petit, M.C.; Ducreux, D. [Dept. of Neuroradiology, Hopital Bicetre, Kremlin-Bicetre (France); Lozeron, P. [Dept. of Neurology, Hopital Bicetre, Kremlin-Bicetre (France)

    2003-03-01

    Our aim is to illustrate the contribution of MRI to diagnosis of lesions of the lower-limb nerve trunks. We report six patients who had clinical and electrophysiological examination for a peroneal or tibial nerve palsy. MRI of the knee showed in three cases a nonenhancing cystic lesion of the peroneal nerve suggesting an intraneural ganglion cyst, confirmed by histological study in one case. One patient with known neurofibromatosis had an enhancing nodular lesion of the peroneal nerve compatible with a neurofibroma. Two patients had diffuse hypertrophy with high signal on T2-weighted images, without contrast enhancement of the sciatic nerve or its branches. These lesions were compatible with localised hypertrophic neuropathy. In one case, biopsy of the superficial branch of the peroneal nerve showed insignificant axonal degeneration. MRI can provide information about the size and site of the abnormal segment of a nerve before treatment and can be used to distinguish different patterns of focal lesion. (orig.)

  12. Role of metallothioneins in peripheral nerve function and regeneration

    DEFF Research Database (Denmark)

    Ceballos, D; Lago, N; Verdú, E

    2003-01-01

    The physiological role of the metallothionein (MT) family of proteins during peripheral nerve injury and regeneration was examined in Mt1+ 2 and Mt3 knockout (KO) mice. To this end, the right sciatic nerve was crushed, and the regeneration distance was evaluated by the pinch test 2-7 days....... The improved regeneration observed with the Mt3 KO mice was confirmed by compound nerve action potentials that were recorded from digital nerves at 14 dpl only in this group. We conclude that Mt3 normally inhibits peripheral nerve regeneration........ Moreover, the number of regenerating axons in the distal tibial nerve was significantly higher in Mt3KO mice than in the other two strains at 14 dpl. Immunoreactive profiles to protein gene product 9.5 were present in the epidermis and the sweat glands of the plantar skin of the hindpaw of the Mt3 KO group...

  13. The Relationship between Peripheral Nerve Conduction Velocity and Ophthalmological Findings in Type 2 Diabetes Patients with Early Diabetic Retinopathy

    Directory of Open Access Journals (Sweden)

    Azusa Ito

    2018-01-01

    Full Text Available Purpose. Nerve conduction velocity (NCV is an indicator of neuronal damage in the distal segment of the peripheral nerves. Here, we determined the association between NCV and other systemic and ocular clinical findings, in type 2 diabetes patients with early diabetic retinopathy (DR. Methods. This study included 42 eyes of 42 type 2 diabetes patients (median age: 54 years with no DR or with mild nonproliferative DR. Standard statistical techniques were used to determine associations between clinical findings. Results. Sural sensory conduction velocity (SCV and tibial motor conduction velocity (MCV were significantly lower in mild nonproliferative DR patients than patients with no DR (P=0.008 and P=0.01, resp.. Furthermore, logistic regression analyses revealed that sural SCV and tibial MCV were independent factors contributing to the presence of mild nonproliferative DR (OR 0.83, P=0.012 and OR 0.69 P=0.02, resp.. Tibial MCV was correlated with choroidal thickness (CT (P=0.01, and a multiple regression analysis revealed that age, tibial MCV, and carotid intima-media thickness were independent associating factors with CT (P=0.035, P=0.015, and P=0.008, resp.. Conclusions. Our findings suggest that reduced NCV may be closely associated with early DR in type 2 diabetes patients. Thus, reduced nerve conduction is a potential early biomarker of DR.

  14. Effects of patterned peripheral nerve stimulation on soleus spinal motor neuron excitability

    DEFF Research Database (Denmark)

    Jimenez, Samuel; Mordillo-Mateos, Laura; Dileone, Michele

    2018-01-01

    obtained was discarded, since non-patterned 15 Hz stimulation at 110% HT led to pain scores similar to those induced by EcTBS at 110% HT, but was not able to induce any modulation of the H reflex amplitude. Together, the results provide first time evidence that peripheral continuous TBS induces a short......Spinal plasticity is thought to contribute to sensorimotor recovery of limb function in several neurological disorders and can be experimentally induced in animals and humans using different stimulation protocols. In healthy individuals, electrical continuous Theta Burst Stimulation (TBS....... In 26 healthy subjects, we examined the effects of electrical TBS given to the tibial nerve in the popliteal fossa on the excitability of lumbar spinal motoneurons as measured by H-reflex amplitude of the soleus muscle evoked by tibial nerve stimulation. Continuous TBS was given at 110% of H...

  15. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb.

    Science.gov (United States)

    Kowalska, Berta; Sudoł-Szopińska, Iwona

    2012-06-01

    The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".

  16. A novel motion analysis approach reveals late recovery in C57BL/6 mice and deficits in NCAM-deficient mice after sciatic nerve crush.

    Science.gov (United States)

    Fey, Andreas; Schachner, Melitta; Irintchev, Andrey

    2010-05-01

    Assessment of motor abilities after sciatic nerve injury in rodents, in particular mice, relies exclusively on walking track (footprint) analysis despite known limitations of this method. Using principles employed recently for video-based motion analyses after femoral nerve and spinal cord injuries, we have designed and report here a novel approach for functional assessments after sciatic nerve lesions in mice. Functional deficits are estimated by angle and distance measurements on single video frames recorded during beam-walking and inclined ladder climbing. Analyses of adult C57BL/6J mice after crush of the sciatic, tibial, or peroneal nerve allowed the identification of six numerical parameters, detecting impairments of the plantar flexion of the foot and the toe spread. Some of these parameters, as well as footprint functional indices, revealed severe impairment after crush injury of the sciatic or tibial, but not the peroneal nerve, and complete recovery within 3 weeks after lesion. Other novel estimates, however, showed that complete recovery is reached as late as 2-3 months after sciatic nerve crush. These measures detected both tibial and peroneal dysfunction. In contrast to the complete restoration of function in wild-type mice (100%), our new parameters, in contrast to the sciatic functional index, showed incomplete recovery (85%) 90 days after sciatic nerve crush in mice deficient in the neural cell adhesion molecule (NCAM). We conclude that the novel video-based approach is more precise, sensitive, and versatile than established tests, allowing objective numerical assessment of different motor functions in a sciatic nerve injury paradigm in mice.

  17. Assessment of nerve ultrastructure by fibre-optic confocal microscopy.

    Science.gov (United States)

    Cushway, T R; Lanzetta, M; Cox, G; Trickett, R; Owen, E R

    1996-01-01

    Fibre-optic technology combined with confocality produces a microscope capable of optical thin sectioning. In this original study, tibial nerves have been stained in a rat model with a vital dye, 4-(4-diethylaminostyryl)-N-methylpyridinium iodide, and analysed by fibre-optic confocal microscopy to produce detailed images of nerve ultrastructure. Schwann cells, nodes of Ranvier and longitudinal myelinated sheaths enclosing axons were clearly visible. Single axons appeared as brightly staining longitudinal structures. This allowed easy tracing of multiple signal axons within the nerve tissue. An accurate measurement of internodal lengths was easily accomplished. This technique is comparable to current histological techniques, but does not require biopsy, thin sectioning or tissue fixing. This study offers a standard for further in vivo microscopy, including the possibility of monitoring the progression of nerve regeneration following microsurgical neurorraphy.

  18. The effect of cryotherapy on nerve conduction velocity, pain threshold and pain tolerance.

    Science.gov (United States)

    Algafly, Amin A; George, Keith P

    2007-06-01

    To determine the impact of the application of cryotherapy on nerve conduction velocity (NCV), pain threshold (PTH) and pain tolerance (PTO). A within-subject experimental design; treatment ankle (cryotherapy) and control ankle (no cryotherapy). Hospital-based physiotherapy laboratory. A convenience sample of adult male sports players (n = 23). NCV of the tibial nerve via electromyogram as well as PTH and PTO via pressure algometer. All outcome measures were assessed at two sites served by the tibial nerve: one receiving cryotherapy and one not receiving cryotherapy. In the control ankle, NCV, PTH and PTO did not alter when reassessed. In the ankle receiving cryotherapy, NCV was significantly and progressively reduced as ankle skin temperature was reduced to 10 degrees C by a cumulative total of 32.8% (pCryotherapy led to an increased PTH and PTO at both assessment sites (pcryotherapy can increase PTH and PTO at the ankle and this was associated with a significant decrease in NCV. Reduced NCV at the ankle may be a mechanism by which cryotherapy achieves its clinical goals.

  19. Peripheral nervous system maturation in preterm infants: longitudinal motor and sensory nerve conduction studies.

    Science.gov (United States)

    Lori, S; Bertini, Giovanna; Bastianelli, M; Gabbanini, S; Gualandi, D; Molesti, E; Dani, C

    2018-04-10

    To study the evolution of sensory-motor nerves in the upper and lower limbs in neurologically healthy preterm infants and to use sensory-motor studies to compare the rate of maturation in preterm infants at term age and full-term healthy neonates. The study comprised 26 neurologically normal preterm infants born at 23-33 weeks of gestational age, who underwent sensory nerve conduction and motor nerve conduction studies from plantar medial and median nerves and from tibial and ulnar nerves, respectively. We repeated the same neurophysiological studies in 19 of the preterm infants every 2 weeks until postnatal term age. The data from the preterm infants at term was matched with a group of ten full-term babies a few days after birth. The motor nerve conduction velocity of the tibial and ulnar nerves showed progressive increases in values in relation to gestational age, but there was a decrease of values in distal latencies and F wave latencies. Similarly, there was a gradual increase of sensory nerve conduction velocity values of the medial plantar and median nerves and decreases in latencies in relation to gestational age. At term age, the preterm infants showed significantly lower values of conduction velocities and distal latencies than the full-term neonates. These results were probably because the preterm infants had significantly lower weights, total length and, in particular, distal segments of the limbs at term age. The sensory-motor conduction parameters were clearly related to gestational age, but extrauterine life did not affect the maturation of the peripheral nervous system in the very preterm babies who were neurologically healthy.

  20. Anatomic single-bundle ACL surgery: consequences of tibial tunnel diameter and drill-guide angle on tibial footprint coverage.

    Science.gov (United States)

    Van der Bracht, H; Verhelst, L; Stuyts, B; Page, B; Bellemans, J; Verdonk, P

    2014-05-01

    To investigate the consequences of differences in drill-guide angle and tibial tunnel diameter on the amount of tibial anatomical anterior cruciate ligament (ACL) footprint coverage and the risk of overhang of the tibial tunnel aperture over the edges of the native tibial ACL footprint. Twenty fresh-frozen adult human knee specimens with a median age of 46 years were used for this study. Digital templates mimicking the ellipsoid aperture of tibial tunnels with a different drill-guide angle and a different diameter were designed. The centres of these templates were positioned over the geometric centre of the tibial ACL footprint. The amount of tibial ACL footprint coverage and overhang was calculated. Risk factors for overhang were determined. Footprint coverage and the risk of overhang were also compared between a lateral tibial tunnel and a classic antero-medial tibial tunnel. A larger tibial tunnel diameter and a smaller drill-guide angle both will create significant more footprint coverage and overhang. In 45% of the knees, an overhang was created with a 10-mm diameter tibial tunnel with drill-guide angle 45°. Furthermore, a lateral tibial tunnel was found not to be at increased risk of overhang. A larger tibial tunnel diameter and a smaller drill-guide angle both will increase the amount of footprint coverage. Inversely, larger tibial tunnel diameters and smaller drill-guide angles will increase the risk of overhang of the tibial tunnel aperture over the edges of the native tibial ACL footprint. A lateral tibial tunnel does not increase the risk of overhang.

  1. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”.

  2. A multiparametric assay for quantitative nerve regeneration evaluation.

    Science.gov (United States)

    Weyn, B; van Remoortere, M; Nuydens, R; Meert, T; van de Wouwer, G

    2005-08-01

    We introduce an assay for the semi-automated quantification of nerve regeneration by image analysis. Digital images of histological sections of regenerated nerves are recorded using an automated inverted microscope and merged into high-resolution mosaic images representing the entire nerve. These are analysed by a dedicated image-processing package that computes nerve-specific features (e.g. nerve area, fibre count, myelinated area) and fibre-specific features (area, perimeter, myelin sheet thickness). The assay's performance and correlation of the automatically computed data with visually obtained data are determined on a set of 140 semithin sections from the distal part of a rat tibial nerve from four different experimental treatment groups (control, sham, sutured, cut) taken at seven different time points after surgery. Results show a high correlation between the manually and automatically derived data, and a high discriminative power towards treatment. Extra value is added by the large feature set. In conclusion, the assay is fast and offers data that currently can be obtained only by a combination of laborious and time-consuming tests.

  3. Anatomical variations between the sciatic nerve and the piriformis muscle: a contribution to surgical anatomy in piriformis syndrome.

    Science.gov (United States)

    Natsis, Konstantinos; Totlis, Trifon; Konstantinidis, George A; Paraskevas, George; Piagkou, Maria; Koebke, Juergen

    2014-04-01

    To detect the variable relationship between sciatic nerve and piriformis muscle and make surgeons aware of certain anatomical features of each variation that may be useful for the surgical treatment of the piriformis syndrome. The gluteal region of 147 Caucasian cadavers (294 limbs) was dissected. The anatomical relationship between the sciatic nerve and the piriformis muscle was recorded and classified according to the Beaton and Anson classification. The literature was reviewed to summarize the incidence of each variation. The sciatic nerve and piriformis muscle relationship followed the typical anatomical pattern in 275 limbs (93.6 %). In 12 limbs (4.1 %) the common peroneal nerve passed through and the tibial nerve below a double piriformis. In one limb (0.3 %) the common peroneal nerve coursed superior and the tibial nerve below the piriformis. In one limb (0.3 %) both nerves penetrated the piriformis. In one limb (0.3 %) both nerves passed above the piriformis. Four limbs (1.4 %) presented non-classified anatomical variations. When a double piriformis muscle was present, two different arrangements of the two heads were observed. Anatomical variations of the sciatic nerve around the piriformis muscle were present in 6.4 % of the limbs examined. When dissection of the entire piriformis is necessary for adequate sciatic nerve decompression, the surgeon should explore for the possible existence of a second tendon, which may be found either inferior or deep to the first one. Some rare, unclassified variations of the sciatic nerve should be expected during surgical intervention of the region.

  4. Anatomical Origin of Abnormal Somatosensory-Evoked Potential (SEP) in Adolescent Idiopathic Scoliosis With Different Curve Severity and Correlation With Cerebellar Tonsillar Level Determined by MRI.

    Science.gov (United States)

    Chau, Wai Wang; Chu, Winnie C W; Lam, Tsz Ping; Ng, Bobby K W; Fu, Linda L K; Cheng, Jack C Y

    2016-05-01

    A prospective cohort study. The aim of this study was to compare the somatosensory-evoked potential (SEP) findings of adolescent idiopathic scoliosis (AIS) subjects of different curve severity with age- and gender-matched controls and to evaluate any correlation between the site of the SEP abnormality with cerebellar tonsillar level measured by magnetic resonance imaging (MRI). Our previous studies showed that a higher percentage of SEP abnormality and cerebellar tonsillar ectopia was present in AIS patients than in normal controls. However, the relationship between the anatomical site of the neurophysiological abnormality and the severity in AIS patients has not been defined. SEP measurement was conducted on 91 Chinese AIS girls with major right thoracic curve of different curve severity (mild, moderate, severe) and 49 matched normal controls. Waveform characteristics (latency and amplitude) were compared among groups. Specific location of SEP abnormality was identified from tibial to cortical levels. Cerebellar tonsillar ectopia was defined by the previously established reference line between basion and opisthion on MRI. Significant prolonged P37 latency was found on the right side between severe AIS patients and normal controls, while increased inter-side P37 latency difference was found between severe versus moderate, and severe versus normal controls. Cerebellar tonsillar ectopia was detected in 27.3% of severe group, 5.8% to 6.7% in mild and moderate group, but none in normal controls. Abnormal SEP occurred superior to C5 region in all surgical (severe) patients, of whom 58% had cerebellar tonsillar ectopia. AIS patients showed significant prolonged latency and increased latency difference on the side of major curvature. The incidence of SEP abnormality increased with curve severity and occurred above the C5 level. The findings suggested that there was a subgroup of progressive AIS with subclinical neurophysiological dysfunction, associated with underlying

  5. Muscle involvement in leprosy: study of the anterior tibial muscle in 40 patients Alterações musculares na lepra: estudo do músculo tibial anterior em 40 pacientes

    Directory of Open Access Journals (Sweden)

    LINEU CESAR WERNECK

    1999-09-01

    Full Text Available The involvement of skeletal striated muscle in leprosy is considered secondary due to peripheral neuropathy, but some studies point it to a primary muscle lesion. In order to investigate the muscle involvement in leprosy, we studied 40 patients (lepromatous 23, tuberculoid 13, borderline 2 and indeterminate 2. The motor nerve conduction of the peroneal nerves had a reduction of the velocity, decreased compound muscle action potential and sometimes absence of potentials. The electromyographic study of the anterior tibial muscle showed signs of recent and chronic denervation in 77.5% of the cases and no myopathic potentials. The anterior tibial muscle biopsy revealed denervation in 45% of the cases, interstitial inflammatory myopathy in 30% and mixed (myopathic and neuropathic pattern in 12.5%. Acid fast bacillus was detected in 25% of the cases, always in the interstitial tissue. Inflammatory reaction was present in the interstitial space and in patients with the lepromatous type. The histological findings clearly defined the presence of the so-called "Leprous Interstitial Myositis" on the top of denervation signs.O envolvimento do músculo estriado na lepra é considerado secundário à lesão dos nervos periféricos, mas alguns estudos relataram acometimento muscular primário. A fim de verificar esta controvérsia estudamos 40 pacientes com lepra, sendo 23 da forma lepromatosa, 13 da tuberculoide, 2 borderline e 2 indeterminada. Realizamos a neurocondução do nervo peroneiro, junto com eletromiografia e biópsia do músculo tibial anterior. Encontramos redução de velocidade de condução, da amplitude e algumas vezes ausência de potenciais no nervo peroneiro. A eletromiografia do tibial anterior mostrou sinais de desinervação recente e crônica em 77,5% dos casos e não foi encontrada evidência de padrão "miopático". A biópsia do músculo tibial anterior revelou desinervação em 45% dos casos, miopatia inflamatória intersticial em

  6. Sensory nerve cross-anastomosis and electrical muscle stimulation synergistically enhance functional recovery of chronically denervated muscle.

    Science.gov (United States)

    Willand, Michael P; Holmes, Michael; Bain, James R; de Bruin, Hubert; Fahnestock, Margaret

    2014-11-01

    Long-term muscle denervation leads to severe and irreversible atrophy coupled with loss of force and motor function. These factors contribute to poor functional recovery following delayed reinnervation. The authors' previous work demonstrated that temporarily suturing a sensory nerve to the distal motor stump (called sensory protection) significantly reduces muscle atrophy and improves function following reinnervation. The authors have also shown that 1 month of electrical stimulation of denervated muscle significantly improves function and reduces atrophy. In this study, the authors tested whether a combination of sensory protection and electrical stimulation would enhance functional recovery more than either treatment alone. Rat gastrocnemius muscles were denervated by cutting the tibial nerve. The peroneal nerve was then sutured to the distal tibial stump following 3 months of treatment (i.e., electrical stimulation, sensory protection, or both). Three months after peroneal repair, functional and histologic measurements were taken. All treatment groups had significantly higher muscle weight (pstimulation or sensory protection alone. The combined treatment also produced motor unit counts significantly greater than sensory protection alone (p<0.05). The combination treatment synergistically reduces atrophy and improves reinnervation and functional measures following delayed nerve repair, suggesting that these approaches work through different mechanisms. The authors' research supports the clinical use of both modalities together following peripheral nerve injury.

  7. Tibial Plateau Fractures

    DEFF Research Database (Denmark)

    Elsøe, Rasmus

    This PhD thesis reported an incidence of tibial plateau fractures of 10.3/100,000/year in a complete Danish regional population. The results reported that patients treated for a lateral tibial plateau fracture with bone tamp reduction and percutaneous screw fixation achieved a satisfactory level...... with only the subgroup Sport significantly below the age matched reference population. The thesis reports a level of health related quality of life (Eq5d) and disability (KOOS) significantly below established reference populations for patients with bicondylar tibial plateau fracture treated with a ring...... fixator, both during treatment and at 19 months following injury. In general, the thesis demonstrates that the treatment of tibial plateau fractures are challenging and that some disabilities following these fractures must be expected. Moreover, the need for further research in the area, both with regard...

  8. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device.

    Science.gov (United States)

    Patil, Shantanu; D'Lima, Darryl D; Fait, James M; Colwell, Clifford W

    2007-02-01

    The outcomes of knee arthroplasty have been shown to be affected by component alignment. Intramedullary and extramedullary alignment instrumentation are fairly effective for achieving the desired mean tibial component coronal alignment. However, there are outliers representing >3 degrees of varus or valgus alignment with respect to the anatomic tibial shaft axis. We measured the efficacy of a custom tibial planing device for reducing the outliers in tibial alignment. We designed a tibial planing tool in an effort to improve tibial alignment. In one cohort (100 knees), we used traditional intramedullary alignment instrumentation to make the tibial bone cut. In a second cohort (120 knees), we used intramedullary alignment instrumentation to make the cut and also used a custom tool to check the cut and to correct an inexact cut. Tibial tray alignment relative to the long axis of the tibial shaft was measured in the coronal and sagittal planes on postoperative radiographs. The target coronal alignment was 90 degrees with respect to the tibial shaft axis (with alignment). A total of 100 anteroposterior radiographs and sixty-five lateral radiographs were analyzed for the group that was treated with traditional instrumentation alone, and a total of 120 anteroposterior radiographs and fifty-five lateral radiographs were analyzed for the group that was treated with use of the custom tibial planing device. The mean coronal alignment of the tibial component was 89.5 degrees +/- 2.1 degrees in the group that was treated with traditional instrumentation alone and 89.6 degrees +/- 1.4 degrees in the group that was treated with use of the custom planing device. Although the mean coronal alignment was not significantly different, the number of outliers was substantially reduced when the custom planing device was used. All 120 components that had been aligned with use of the custom planing device were within 3 degrees of the target coronal alignment, compared with only eighty

  9. Integration of the Residual Limb with Prostheses via Direct Skin-Bone-Peripheral Nerve Interface

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0791 TITLE: Integration of the Residual Limb with Prostheses via Direct Skin- Bone-Peripheral Nerve Interface...ABOVE ADDRESS. 1. REPORT DATE October 2017 2. REPORT TYPE Annual 3. DATES COVERED 30 Sep 2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Integration of the...translational study to develop Skin and Bone Integrated Pylon with Peripheral Neural Interface (SBIP-PNI) directly attached to the residuum and the

  10. The Level of Fibula Osteotomy and Incidence of Peroneal Nerve ...

    African Journals Online (AJOL)

    2010-06-29

    Jun 29, 2010 ... Journal of Surgical Technique and Case Report | Jan-Jun 2010 | Vol-2 | Issue-1. 17. The Level of Fibula Osteotomy and Incidence of Peroneal. Nerve Palsy in Proximal Tibial Osteotomy. A. O. Ogbemudia, P. F. A. Umebese, A. Bafor, E. Igbinovia, P. E. Ogbemudia. INTRODUCTION. Osteotomy of the fibula is ...

  11. Percutaneous tibial nerve stimulation versus electrical stimulation with pelvic floor muscle training for overactive bladder syndrome in women: results of a randomized controlled study

    Directory of Open Access Journals (Sweden)

    Carlo Vecchioli Scaldazza

    Full Text Available ABSTRACT Introduction This study compared percutaneous tibial nerve stimulation (PTNS versus electrical stimulation with pelvic floor muscle training (ES + PFMT in women with overactive bladder syndrome (OAB. Materials and Methods 60 women with OAB were enrolled. Patients were randomized into two groups. In group A, women underwent ES with PFMT, in group B women underwent PTNS. Results A statistically significant reduction in the number of daily micturitions, episodes of nocturia and urge incontinence was found in the two groups but the difference was more substantial in women treated with PTNS; voided volume increased in both groups. Quality of life improved in both groups, whereas patient perception of urgency improved only in women treated with PTNS. Global impression of improvement revealed a greater satisfaction in patients treated with PTNS. Conclusion This study demonstrates the effectiveness of PTNS and ES with PFMT in women with OAB, but greater improvements were found with PTNS.

  12. Contribución de fibras mielínicas provenientes de los nervios espinales lumbares L4, L5 y L6 al nervio ciático de rata adulta y sus ramas principales Contribution of myelunated fibers from spinal L4, L5 and L6 nerves to the sciatic nerve and its main branches in the adult rat

    Directory of Open Access Journals (Sweden)

    Hernán Hurtado

    2000-04-01

    Full Text Available El nervio ciático de la rata está formado por los nervios espinales (ne lumbares L4, L5 y L6. Sin embargo, aún no se ha definido el aporte en fibras mielínicas de estos nervios espinales a lo largo del tronco nervioso. En este estudio se transectaron selectivamente los NE L4, L5 y L4-L5. Luego de una semana se disecaron los nervios ciático, tibial, sural y peroneal. Estas muestras se fijaron y procesaron para microscopía óptica y a partir de cortes coloreados con azul de toluidina se contaron las fibras mielínicas degeneradas y normales. L4 contribuyó con fibras mielínicas principalmente al nervio peroneal y L5 a los nervios ciático, tibial y sural. En general, el aporte de L6 fue menor y variable a lo largo del tronco nervioso comparado con las otras dos ramas espinales. Nuestros resultados brindan información valiosa para posteriores estudios que busquen correlacionar la contribución de los nervios espinales que componen el ciático y sus ramas principales con la función de la extremidad inferior. The rat sciatic nerve is composed by the L4, L5 and L6 lumbar spinal nerves. However, the contribution in myelinated fibers originating from these nerves along this nervous trunk has not yet been defined. In the present study, the L4, L5 and L4-L5 spinal nerves were selectively transected. After one week the sciatic, tibial, sural and peroneal nerves were dissected. These samples were fixed and processed for optical microscopy, and both degenerated and normal myelinated fibers were counted in toluidine blue-stained semi-thin sections. L4 contributed with myelinated fibers mainly to the peroneal nerve, and L5 to the sciatic, tibial and sural nerves. In general, the contribution of L6 was smaller and variable along the nervous trunk in comparison to the other two spinal branches. Our results give key information for further studies looking to correlate the contribution of spinal nerves making part of the sciatic nerve and its main

  13. Tibial bone fractures occurring after medioproximal tibial bone grafts for oral and maxillofacial reconstruction.

    Science.gov (United States)

    Kim, Il-Kyu; Cho, Hyun-Young; Pae, Sang-Pill; Jung, Bum-Sang; Cho, Hyun-Woo; Seo, Ji-Hoon

    2013-12-01

    Oral and maxillofacial defects often require bone grafts to restore missing tissues. Well-recognized donor sites include the anterior and posterior iliac crest, rib, and intercalvarial diploic bone. The proximal tibia has also been explored as an alternative donor site. The use of the tibia for bone graft has many benefits, such as procedural ease, adequate volume of cancellous and cortical bone, and minimal complications. Although patients rarely complain of pain, swelling, discomfort, or dysfunction, such as gait disturbance, both patients and surgeons should pay close attention to such after effects due to the possibility of tibial fracture. The purpose of this study is to analyze tibial fractures that occurring after osteotomy for a medioproximal tibial graft. An analysis was intended for patients who underwent medioproximal tibial graft between March 2004 and December 2011 in Inha University Hospital. A total of 105 subjects, 30 females and 75 males, ranged in age from 17 to 78 years. We investigated the age, weight, circumstance, and graft timing in relation to tibial fracture. Tibial fractures occurred in four of 105 patients. There were no significant differences in graft region, shape, or scale between the fractured and non-fractured patients. Patients who undergo tibial grafts must be careful of excessive external force after the operation.

  14. Percutaneous Tibial Nerve Stimulation in the Office Setting: Real-world Experience of Over 100 Patients.

    Science.gov (United States)

    Sirls, Evan R; Killinger, Kim A; Boura, Judith A; Peters, Kenneth M

    2018-03-01

    To examine the outcomes and compliance with percutaneous tibial nerve stimulation (PTNS) for overactive bladder (OAB) symptoms. Adults who had PTNS from June 30, 2011, to October 8, 2015, were retrospectively reviewed for demographics, copay, travel distance, employment status, history, symptoms, and treatments used before, during, and after PTNS. Pearson chi-square test, Fisher exact test, Wilcoxon rank and paired t test were performed. Of 113 patients (mean age 75 ± 12 years), most were women (65.5%), married (78.1%), and retired or unemployed (80.2%). The median distance to the clinic was 8.1 mi, and the median copay was $0. The most common indication for PTNS was nocturia (92.9%) followed by OAB with urgency urinary incontinence (75.2%) and urinary urgency and/or frequency (24.8%). Prior treatments included anticholinergics (75.2%), mirabegron (36.6%), behavioral modification (29.2%), pelvic floor physical therapy (18.6%), and others (19.5%). Patients completed a mean of 10.5 ± 3 of 12 planned weekly PTNS treatments. Of 105 patients, 40 (38.1%) used concomitant treatments (most commonly anticholinergics). Of 87 patients, 62 (71.3%) had decreased symptoms at 6 weeks, and of 85 patients, 60 (70.6%) had decreased symptoms at 12 weeks. The majority (82; 75.6%) completed all 12 weekly treatments and 45 (54.9%) completed 3 (median) monthly maintenance treatments. The most common reason for noncompliance was lack of efficacy. Visit copay, employment status, and distance to the clinic were not associated with failure to complete weekly treatments or progression to monthly maintenance. Although most patients' symptoms decreased after weekly PTNS, nonadherence to maintenance and lack of efficacy may limit long-term feasibility. Copay and distance traveled were not associated with noncompliance. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. The effect of tibial plateau leveling osteotomy position on cranial tibial subluxation: an in vitro study.

    Science.gov (United States)

    Kowaleski, Michael P; Apelt, Detlef; Mattoon, John S; Litsky, Alan S

    2005-01-01

    To compare centered versus distal tibial plateau leveling osteotomy (TPLO) position on cranial tibial subluxation, postoperative tibial plateau angle (TPA), and tibial long axis shift (TLAS). In vitro biomechanical evaluation. Six pairs of canine cadaveric hind limbs. One limb of each pair was randomly assigned to the distal (TPLO-D) or centered (TPLO-C) osteotomy group. Cranial tibial subluxation (CTS) under load was quantified sequentially under 3 conditions: intact, after cranial cruciate ligament transection, and after TPLO; a corrected CTS value was also calculated. Postoperative TPA and TLAS were measured. Comparisons were made using 1-way repeated measures ANOVA with a Tukey's multiple comparison post hoc test for CTS, and a Wilcoxon's sign rank test for TPA and TLAS. Significance was set at Pcranial tibial thrust. The centered osteotomy position is geometrically more precise, and biomechanically more effective than the distal position.

  16. Diffusion tensor imaging can be used to detect lesions in peripheral nerves in patients with chronic inflammatory demyelinating polyneuropathy treated with subcutaneous immunoglobulin

    Energy Technology Data Exchange (ETDEWEB)

    Markvardsen, Lars H.; Andersen, Henning [Aarhus University Hospital, Department of Neurology, Aarhus C (Denmark); Vaeggemose, Michael [Aarhus University Hospital, Department of Neurology, Aarhus C (Denmark); Aarhus University Hospital, Department of Diagnostic Imaging: MR Research Centre, Aarhus (Denmark); Ringgaard, Steffen [Aarhus University Hospital, Department of Diagnostic Imaging: MR Research Centre, Aarhus (Denmark)

    2016-08-15

    Magnetic resonance imaging (MRI) with diffusion tensor imaging (DTI) has shown that fractional anisotropy (FA) is lower in peripheral nerves in chronic inflammatory demyelinating polyneuropathy (CIDP). We examined whether DTI correlates to muscle strength or impairment. MRI of sciatic and tibial nerves was performed on 3-T MR scanner by obtaining T2- and DTI-weighted sequences with fat saturation. On each slice of T2-weighted (T2w) and DTI, the tibial and sciatic nerves were segmented and served for calculation of signal intensity. On DTI images, pixel-by-pixel calculation of FA and apparent diffusion coefficient (ADC) was done. Muscle strength at knee and ankle was determined by isokinetic dynamometry and severity of CIDP by neuropathy impairment score (NIS). Fourteen CIDP patients treated with subcutaneous immunoglobulin were compared to gender- and age-matched controls. T2w values expressed as a nerve/muscle ratio (nT2w) were unchanged in CIDP versus controls 0.93 ± 0.21 versus 1.02 ± 0.21 (P = 0.10). FA values were lower in CIDP compared to controls 0.38 ± 0.07 versus 0.45 ± 0.05 (P < 0.0001), and ADC values were higher in CIDP versus controls 1735 ± 232 versus 1593 ± 116 x 10{sup -6} mm{sup 2}/s (P = 0.005). In CIDP, FA values correlated to clinical impairment (NIS) (r = -0.57, P = 0.03), but not to muscle strength. FA value in the sciatic nerve distinguishes CIDP from controls with a sensitivity and a specificity of 92.9 %. CIDP patients have unchanged nT2w values, lower FA values, and higher ADC values of sciatic and tibial nerves compared to controls. FA values correlated to NIS but were unrelated to muscle strength. DTI of sciatic nerves seems promising to differentiate CIDP from controls. (orig.)

  17. Proximal tibial osteophytes and their relationship with the height of the tibial spines of the intercondylar eminence: paleopathological study

    International Nuclear Information System (INIS)

    Hayeri, Mohammad Reza; Shiehmorteza, Masoud; Trudell, Debra J.; Resnick, Donald; Hefflin, Tori

    2010-01-01

    Tibial spiking (i.e., spurring of tibial spines), eburnation, and osteophytes are considered features of osteoarthritis. This investigation employed direct inspection of the medial and lateral tibial plateaus in paleopathological specimens to analyze the frequency and morphological features of osteoarthritis and to define any relationship between the size of osteophytes and that of the intercondylar tibial spines. A total of 35 tibial bone specimens were evaluated for the degree of osteoarthritis and presence of eburnation. Each plateau was also divided into four quadrants and the presence and size of bone outgrowths were recorded in each quadrant. The ''medial/lateral tibial intercondylar spine index'' for each specimen was calculated as follows: (medial/lateral intercondylar tibial spine height)/(anteroposterior width of the superior tibial surface). The relationships between medial and lateral tibial height indexes with the degree of osteoarthritis were then tested. Osteophytes were observed more frequently in the anterior quadrants of both tibial plateaus than in the posterior quadrants (29 vs 16 for the medial tibial plateau [p = 0.01] and 28 vs 20 for the lateral tibial plateau [p = 0.04]). Eburnation was seen more frequently in the posterior regions of both tibial plateaus than in the anterior regions (17 vs 5, p < 0.01). In specimens with no signs of osteoarthritis the lateral intercondylar tibial index was significantly lower than that in specimens with some degree of osteoarthritis (p = 0.02). The medial intercondylar tibial index of the specimens with no signs of osteoarthritis was not significantly different from that of the specimens with some degree of osteoarthritis (p = 0.45). There was a positive correlation between the lateral spine height index and the overall grading of osteoarthritis, (r = 0.6, p < 0.01). In the anteromedial and posteromedial quadrants of the lateral tibial plateau, the association between the lateral intercondylar tibial spine

  18. Proximal tibial osteophytes and their relationship with the height of the tibial spines of the intercondylar eminence: paleopathological study

    Energy Technology Data Exchange (ETDEWEB)

    Hayeri, Mohammad Reza [Children' s National Medical Center, Department of Radiology, Washington, DC (United States); Shiehmorteza, Masoud; Trudell, Debra J.; Resnick, Donald [University of California San Diego, Department of Radiology, San Diego, CA (United States); Hefflin, Tori [Museum of Man San Diego, San Diego, CA (United States)

    2010-09-15

    Tibial spiking (i.e., spurring of tibial spines), eburnation, and osteophytes are considered features of osteoarthritis. This investigation employed direct inspection of the medial and lateral tibial plateaus in paleopathological specimens to analyze the frequency and morphological features of osteoarthritis and to define any relationship between the size of osteophytes and that of the intercondylar tibial spines. A total of 35 tibial bone specimens were evaluated for the degree of osteoarthritis and presence of eburnation. Each plateau was also divided into four quadrants and the presence and size of bone outgrowths were recorded in each quadrant. The ''medial/lateral tibial intercondylar spine index'' for each specimen was calculated as follows: (medial/lateral intercondylar tibial spine height)/(anteroposterior width of the superior tibial surface). The relationships between medial and lateral tibial height indexes with the degree of osteoarthritis were then tested. Osteophytes were observed more frequently in the anterior quadrants of both tibial plateaus than in the posterior quadrants (29 vs 16 for the medial tibial plateau [p = 0.01] and 28 vs 20 for the lateral tibial plateau [p = 0.04]). Eburnation was seen more frequently in the posterior regions of both tibial plateaus than in the anterior regions (17 vs 5, p < 0.01). In specimens with no signs of osteoarthritis the lateral intercondylar tibial index was significantly lower than that in specimens with some degree of osteoarthritis (p = 0.02). The medial intercondylar tibial index of the specimens with no signs of osteoarthritis was not significantly different from that of the specimens with some degree of osteoarthritis (p = 0.45). There was a positive correlation between the lateral spine height index and the overall grading of osteoarthritis, (r = 0.6, p < 0.01). In the anteromedial and posteromedial quadrants of the lateral tibial plateau, the association between the lateral

  19. MAVEN SEP Calibrated Data Bundle

    Data.gov (United States)

    National Aeronautics and Space Administration — The maven.sep.calibrated Level 2 Science Data Bundle contains fully calibrated SEP data, as well as the raw count data from which they are derived, and ancillary...

  20. Collagen turnover after tibial fractures

    DEFF Research Database (Denmark)

    Joerring, S; Krogsgaard, M; Wilbek, H

    1994-01-01

    Collagen turnover after tibial fractures was examined in 16 patients with fracture of the tibial diaphysis and in 8 patients with fracture in the tibial condyle area by measuring sequential changes in serological markers of turnover of types I and III collagen for up to 26 weeks after fracture....... The markers were the carboxy-terminal extension peptide of type I procollagen (PICP), the amino-terminal extension peptide of type III procollagen (PIIINP), and the pyridinoline cross-linked carboxy-terminal telopeptide of type I collagen (ICTP). The latter is a new serum marker of degradation of type I...... collagen. A group comparison showed characteristic sequential changes in the turnover of types I and III collagen in fractures of the tibial diaphysis and tibial condyles. The turnover of type III collagen reached a maximum after 2 weeks in both groups. The synthesis of type I collagen reached a maximum...

  1. Side-To-Side Nerve Bridges Support Donor Axon Regeneration Into Chronically Denervated Nerves and Are Associated With Characteristic Changes in Schwann Cell Phenotype.

    Science.gov (United States)

    Hendry, J Michael; Alvarez-Veronesi, M Cecilia; Snyder-Warwick, Alison; Gordon, Tessa; Borschel, Gregory H

    2015-11-01

    Chronic denervation resulting from long nerve regeneration times and distances contributes greatly to suboptimal outcomes following nerve injuries. Recent studies showed that multiple nerve grafts inserted between an intact donor nerve and a denervated distal recipient nerve stump (termed "side-to-side nerve bridges") enhanced regeneration after delayed nerve repair. To examine the cellular aspects of axon growth across these bridges to explore the "protective" mechanism of donor axons on chronically denervated Schwann cells. In Sprague Dawley rats, 3 side-to-side nerve bridges were placed over a 10-mm distance between an intact donor tibial (TIB) nerve and a recipient denervated common peroneal (CP) distal nerve stump. Green fluorescent protein-expressing TIB axons grew across the bridges and were counted in cross section after 4 weeks. Immunofluorescent axons and Schwann cells were imaged over a 4-month period. Denervated Schwann cells dedifferentiated to a proliferative, nonmyelinating phenotype within the bridges and the recipient denervated CP nerve stump. As donor TIB axons grew across the 3 side-to-side nerve bridges and into the denervated CP nerve, the Schwann cells redifferentiated to the myelinating phenotype. Bridge placement led to an increased mass of hind limb anterior compartment muscles after 4 months of denervation compared with muscles whose CP nerve was not "protected" by bridges. This study describes patterns of donor axon regeneration and myelination in the denervated recipient nerve stump and supports a mechanism where these donor axons sustain a proregenerative state to prevent deterioration in the face of chronic denervation.

  2. Different nerve ultrasound patterns in charcot-marie-tooth types and hereditary neuropathy with liability to pressure palsies.

    Science.gov (United States)

    Padua, Luca; Coraci, Daniele; Lucchetta, Marta; Paolasso, Ilaria; Pazzaglia, Costanza; Granata, Giuseppe; Cacciavillani, Mario; Luigetti, Marco; Manganelli, Fiore; Pisciotta, Chiara; Piscosquito, Giuseppe; Pareyson, Davide; Briani, Chiara

    2018-01-01

    Nerve ultrasound in Charcot-Marie-Tooth (CMT) disease has focused mostly on the upper limbs. We performed an evaluation of a large cohort of CMT patients in which we sonographically characterized nerve abnormalities in different disease types, ages, and nerves. Seventy patients affected by different CMT types and hereditary neuropathy with liability to pressure palsies (HNPP) were evaluated, assessing median, ulnar, fibular, tibial, and sural nerves bilaterally. Data were correlated with age. Nerve dimensions were correlated with CMT type, age, and nerve site. Nerves were larger in demyelinating than in axonal neuropathies. Nerve involvement was symmetric. CMT1 patients had larger nerves than did patients with other CMT types. Patients with HNPP showed enlargement at entrapment sites. Our study confirms the general symmetry of ultrasound nerve patterns in CMT. When compared with ultrasound studies of nerves of the upper limbs, evaluation of the lower limbs did not provide additional information. Muscle Nerve 57: E18-E23, 2018. © 2017 Wiley Periodicals, Inc.

  3. Neuronal involvement in cisplatin neuropathy

    DEFF Research Database (Denmark)

    Krarup-Hansen, A; Helweg-Larsen, Susanne Elisabeth; Schmalbruch, H

    2007-01-01

    Although it is well known that cisplatin causes a sensory neuropathy, the primary site of involvement is not established. The clinical symptoms localized in a stocking-glove distribution may be explained by a length dependent neuronopathy or by a distal axonopathy. To study whether the whole neuron...... of the foot evoked by a tactile probe showed similar changes to those observed in SNAPs evoked by electrical stimulation. At these doses, somatosensory evoked potentials (SEPs) from the tibial nerve had increased latencies of peripheral, spinal and central responses suggesting loss of central processes...

  4. Median sep and blink reflex in thyroid diseases.

    Science.gov (United States)

    Oflazoğlu, B; Somay, G; Us, O; Surardamar, A; Tanridağ, T

    2006-11-01

    Pathological disturbances of thyroid hormones is associated with central and peripheral nervous system disturbances. The aim of this study is to evaluate median nerve stimulated somatosensory evoked potential (SEP) and blink reflex of thyroid patients (hypo and hyperthyroidism). Median SEP was performed in 40 patients (21 with hyperthyroidism and 19 with hypothyroidism). We evaluated the latencies of N9, N11, N13, P9, P11, P14, N20 and P25 waves and the N9-N20, N9-N13, N13-N20 and P14-N20 interpeak latencies. We compared the results of patients with the control group (26 persons). We found that the N20 latency was longer in patients with hyperthyroidism than in the control group and the difference was statistically significant. There was not any statistically significant difference regarding the N9, N11, N13, P9, P11, P14, N20 and P25 latencies and the N9-N20, N9-N13, N13-N20 and P14-N20 interpeak latencies between hypothyroid patients and controls. We performed the blink reflex study in 28 of 40 patients (14 patients with hyperthyroidism and 14 patients with hypothyroidism). Comparing the R1, R2, CR2 (contralateral R2) latencies and durations of the patients and controls, we found that R2 and CR2 duration was shorter in patients with hyperthyroidism. This difference was statistically significant.

  5. The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty.

    Science.gov (United States)

    Inoue, Shinji; Akagi, Masao; Asada, Shigeki; Mori, Shigeshi; Zaima, Hironori; Hashida, Masahiko

    2016-09-01

    Medial tibial condylar fractures (MTCFs) are a rare but serious complication after unicompartmental knee arthroplasty. Although some surgical pitfalls have been reported for MTCFs, it is not clear whether the varus/valgus tibial inclination contributes to the risk of MTCFs. We constructed a 3-dimensional finite elemental method model of the tibia with a medial component and assessed stress concentrations by changing the inclination from 6° varus to 6° valgus. Subsequently, we repeated the same procedure adding extended sagittal bone cuts of 2° and 10° in the posterior tibial cortex. Furthermore, we calculated the bone volume that supported the tibial component, which is considered to affect stress distribution in the medial tibial condyle. Stress concentrations were observed on the medial tibial metaphyseal cortices and on the anterior and posterior tibial cortices in the corner of cut surfaces in all models; moreover, the maximum principal stresses on the posterior cortex were larger than those on the anterior cortex. The extended sagittal bone cuts in the posterior tibial cortex increased the stresses further at these 3 sites. In the models with a 10° extended sagittal bone cut, the maximum principal stress on the posterior cortex increased as the tibial inclination changed from 6° varus to 6° valgus. The bone volume decreased as the inclination changed from varus to valgus. In this finite element method, the risk of MTCFs increases with increasing valgus inclination of the tibial component and with increased extension of the sagittal cut in the posterior tibial cortex. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Widely distributed SEP events and pseudostreamers

    Science.gov (United States)

    Panasenco, O.; Panasenco, A.; Velli, M.

    2017-12-01

    Our analysis of the pseudostreamer magnetic topology reveals new interesting implications for understanding SEP acceleration in CMEs. The possible reasons for the wide distribution of some SEP events can be the presence of pseudostreamers in the vicinity of the SEP source region which creates conditions for the existence of strong longitudinal spread of energetic particles as well as an anomalous longitudinal solar wind magnetic field component. We reconstructed the 3D magnetic configurations of pseudostreamers with a potential field source surface (PFSS) model, which uses as a lower boundary condition the magnetic field derived from an evolving surface-flux transport model. In order to estimate the possible magnetic connections between the spacecraft and the SEP source region, we used the Parker spiral, ENLIL and PFSS models. We found that in cases of the wide SEP distributions a specific configuration of magnetic field appears to exist at low solar latitudes all the way around the sun, we named this phenomenon a pseudostreamers belt. It appears that the presence of the well developed pseudostreamer or, rather multiple pseudostreamers, organized into the pseudostreamer belt can be considered as a very favorable condition for wide SEP events.

  7. [Tibial periostitis ("medial tibial stress syndrome")].

    Science.gov (United States)

    Fournier, Pierre-Etienne

    2003-06-01

    Medial tibial stress syndrome is characterised by complaints along the posteromedial tibia. Runners and athletes involved in jumping activities may develop this syndrome. Increased stress to stabilize the foot especially when excessive pronation is present explain the occurrence this lesion.

  8. Solar Electric Propulsion (SEP) Tug Power System Considerations

    Science.gov (United States)

    Kerslake, Thomas W.; Bury, Kristen M.; Hojinicki, Jeffrey S.; Sajdak, Adam M.; Scheiddegger, Robert J.

    2011-01-01

    Solar electric propulsion (SEP) technology is truly at the "intersection of commercial and military space" as well as the intersection of NASA robotic and human space missions. Building on the use of SEP for geosynchronous spacecraft station keeping, there are numerous potential commercial and military mission applications for SEP stages operating in Earth orbit. At NASA, there is a resurgence of interest in robotic SEP missions for Earth orbit raising applications, 1-AU class heliocentric missions to near Earth objects (NEOs) and SEP spacecraft technology demonstrations. Beyond these nearer term robotic missions, potential future human space flight missions to NEOs with high-power SEP stages are being considered. To enhance or enable this broad class of commercial, military and NASA missions, advancements in the power level and performance of SEP technologies are needed. This presentation will focus on design considerations for the solar photovoltaic array (PVA) and electric power system (EPS) vital to the design and operation of an SEP stage. The engineering and programmatic pros and cons of various PVA and EPS technologies and architectures will be discussed in the context of operating voltage and power levels. The impacts of PVA and EPS design options on the remaining SEP stage subsystem designs, as well as spacecraft operations, will also be discussed.

  9. Anatomical basis for sciatic nerve block at the knee level.

    Science.gov (United States)

    Barbosa, Fabiano Timbó; Barbosa, Tatiana Rosa Bezerra Wanderley; da Cunha, Rafael Martins; Rodrigues, Amanda Karine Barros; Ramos, Fernando Wagner da Silva; de Sousa-Rodrigues, Célio Fernando

    2015-01-01

    Recently, administration of sciatic nerve block has been revised due to the potential benefit for postoperative analgesia and patient satisfaction after the advent of ultrasound. The aim of this study was to describe the anatomical relations of the sciatic nerve in the popliteal fossa to determine the optimal distance the needle must be positioned in order to realize the sciatic nerve block anterior to its bifurcation into the tibial and common fibular nerve. The study was conducted by dissection of human cadavers' popliteal fossa, fixed in 10% formalin, from the Laboratory of Human Anatomy and Morphology Departments of the Universidade Federal de Alagoas and Universidade de Ciências da Saúde de Alagoas. Access to the sciatic nerve was obtained. 44 popliteal fossa were analyzed. The bifurcation of the sciatic nerve in relation to the apex of the fossa was observed. There was bifurcation in: 67.96% below the apex, 15.90% above the apex, 11.36% near the apex, and 4.78% in the gluteal region. The sciatic nerve bifurcation to its branches occurs at various levels, and the chance to succeed when the needle is placed between 5 and 7 cm above the popliteal is 95.22%. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  10. [Anatomical basis for sciatic nerve block at the knee level].

    Science.gov (United States)

    Barbosa, Fabiano Timbó; Barbosa, Tatiana Rosa Bezerra Wanderley; Cunha, Rafael Martins da; Rodrigues, Amanda Karine Barros; Ramos, Fernando Wagner da Silva; Sousa-Rodrigues, Célio Fernando de

    2015-01-01

    Recently, administration of sciatic nerve block has been revised due to the potential benefit for postoperative analgesia and patient satisfaction after the advent of ultrasound. The aim of this study was to describe the anatomical relations of the sciatic nerve in the popliteal fossa to determine the optimal distance the needle must be positioned in order to realize the sciatic nerve block anterior to its bifurcation into the tibial and common fibular nerve. The study was conducted by dissection of human cadavers' popliteal fossa, fixed in 10% formalin, from the Laboratory of Human Anatomy and Morphology Departments of the Universidade Federal de Alagoas and Universidade de Ciências da Saúde de Alagoas. Access to the sciatic nerve was obtained. 44 popliteal fossa were analyzed. The bifurcation of the sciatic nerve in relation to the apex of the fossa was observed. There was bifurcation in: 67.96% below the apex, 15.90% above the apex, 11.36% near the apex, and 4.78% in the gluteal region. The sciatic nerve bifurcation to its branches occurs at various levels, and the chance to succeed when the needle is placed between 5 and 7 cm above the popliteal is 95.22%. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  11. [Application of tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty].

    Science.gov (United States)

    Li, Guoliang; Han, Guangpu; Zhang, Jinxiu; Ma, Shiqiang; Guo, Donghui; Yuan, Fulu; Qi, Bingbing; Shen, Runbin

    2013-07-01

    To explore the application value of self-made tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty (TKA) for improving the lower extremity force line. Between January and August 2012, 13 cases (21 knees) of osteoarthritis with tibial extra-articular deformity were treated, including 5 males (8 knees) and 8 females (13 knees) with an average age of 66.5 years (range, 58-78 years). The disease duration was 2-5 years (mean, 3.5 years). The knee society score (KSS) was 45.5 +/- 15.5. Extra-articular deformities included 1 case of knee valgus (2 knees) and 12 cases of knee varus (19 knees). Preoperative full-length X-ray films of lower extremities showed 10-21 degrees valgus or varus deformity of tibial extra joint. Self-made tibial mechanical axis locator was used to determine and mark coronal tibial mechanical axis under X-ray before TKA, and then osteotomy was performed with extramedullary positioning device according to the mechanical axis marker.' All incisions healed by first intention, without related complications of infection and joint instability. All patients were followed up 5-12 months (mean, 8.3 months). The X-ray examination showed case of 2.9 degrees knee deviation angle at 3 days after operation, and the accurate rate was 95.2%. No loosening or instability of prosthesis occurred during follow-up. KSS score was 85.5 +/- 15.0 at last follow-up, showing significant difference when compared with preoperative score (t=12.82, P=0.00). The seft-made tibial mechanical axis locator can improve the accurate rate of the lower extremity force line in TKA for tibia extra-articular deformity.

  12. Targeting the ECM to Enhance Drug Delivery in Nf1-Associated Nerve Sheath Tumors

    Science.gov (United States)

    2016-10-01

    development of the principal discipline(s) of the project? • We have learned that the drug PEGPH20, which degrades a component of connective tissue called...AWARD NUMBER: W81XWH-15-1-0114 TITLE: Targeting the ECM to Enhance Drug Delivery in Nf1-Associated Nerve Sheath Tumors PRINCIPAL INVESTIGATOR...14 Sep 2016 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER NF140089 Targeting the ECM to Enhance Drug Delivery in Nf1-Associated Nerve Sheath Tumors 5b

  13. Sacral nerve stimulation increases activation of the primary somatosensory cortex by anal canal stimulation in an experimental model.

    LENUS (Irish Health Repository)

    Griffin, K M

    2011-08-01

    Sacral and posterior tibial nerve stimulation may be used to treat faecal incontinence; however, the mechanism of action is unknown. The aim of this study was to establish whether sensory activation of the cerebral cortex by anal canal stimulation was increased by peripheral neuromodulation.

  14. Asynchronous recruitment of low-threshold motor units during repetitive, low-current stimulation of the human tibial nerve.

    Science.gov (United States)

    Dean, Jesse C; Clair-Auger, Joanna M; Lagerquist, Olle; Collins, David F

    2014-01-01

    Motoneurons receive a barrage of inputs from descending and reflex pathways. Much of our understanding about how these inputs are transformed into motor output in humans has come from recordings of single motor units during voluntary contractions. This approach, however, is limited because the input is ill-defined. Herein, we quantify the discharge of soleus motor units in response to well-defined trains of afferent input delivered at physiologically-relevant frequencies. Constant frequency stimulation of the tibial nerve (10-100 Hz for 30 s), below threshold for eliciting M-waves or H-reflexes with a single pulse, recruited motor units in 7/9 subjects. All 25 motor units recruited during stimulation were also recruited during weak (recruited more units (n = 3/25 at 10 Hz; n = 25/25 at 100 Hz) at shorter latencies (19.4 ± 9.4 s at 10 Hz; 4.1 ± 4.0 s at 100 Hz) than lower frequencies. When a second unit was recruited, the discharge of the already active unit did not change, suggesting that recruitment was not due to increased synaptic drive. After recruitment, mean discharge rate during stimulation at 20 Hz (7.8 Hz) was lower than during 30 Hz (8.6 Hz) and 40 Hz (8.4 Hz) stimulation. Discharge was largely asynchronous from the stimulus pulses with "time-locked" discharge occurring at an H-reflex latency with only a 24% probability. Motor units continued to discharge after cessation of the stimulation in 89% of trials, although at a lower rate (5.8 Hz) than during the stimulation (7.9 Hz). This work supports the idea that the afferent volley evoked by repetitive stimulation recruits motor units through the integration of synaptic drive and intrinsic properties of motoneurons, resulting in "physiological" recruitment which adheres to Henneman's size principle and results in relatively low discharge rates and asynchronous firing.

  15. SEP Mission Design Space for Mars Orbiters

    Science.gov (United States)

    Woolley, Ryan C.; Nicholas, Austin K.

    2015-01-01

    The advancement of solar-electric propulsion (SEP) technologies and larger, light-weight solar arrays offer a tremendous advantage to Mars orbiters in terms of both mass and timeline flexibility. These advantages are multiplied for round-trip orbiters (e.g. potential Mars sample return) where a large total Delta V would be required. In this paper we investigate the mission design characteristics of mission concepts utilizing various combinations and types of SEP thrusters, solar arrays, launch vehicles, launch dates, arrival dates, etc. SEP allows for greater than 50% more mass delivered and launch windows of months to years. We also present the SEP analog to the ballistic Porkchop plot - the "Bacon" plot.

  16. Identification and prediction of diabetic sensorimotor polyneuropathy using individual and simple combinations of nerve conduction study parameters.

    Directory of Open Access Journals (Sweden)

    Alanna Weisman

    Full Text Available OBJECTIVE: Evaluation of diabetic sensorimotor polyneuropathy (DSP is hindered by the need for complex nerve conduction study (NCS protocols and lack of predictive biomarkers. We aimed to determine the performance of single and simple combinations of NCS parameters for identification and future prediction of DSP. MATERIALS AND METHODS: 406 participants (61 with type 1 diabetes and 345 with type 2 diabetes with a broad spectrum of neuropathy, from none to severe, underwent NCS to determine presence or absence of DSP for cross-sectional (concurrent validity analysis. The 109 participants without baseline DSP were re-evaluated for its future onset (predictive validity. Performance of NCS parameters was compared by area under the receiver operating characteristic curve (AROC. RESULTS: At baseline there were 246 (60% Prevalent Cases. After 3.9 years mean follow-up, 25 (23% of the 109 Prevalent Controls that were followed became Incident DSP Cases. Threshold values for peroneal conduction velocity and sural amplitude potential best identified Prevalent Cases (AROC 0.90 and 0.83, sensitivity 80 and 83%, specificity 89 and 72%, respectively. Baseline tibial F-wave latency, peroneal conduction velocity and the sum of three lower limb nerve conduction velocities (sural, peroneal, and tibial best predicted 4-year incidence (AROC 0.79, 0.79, and 0.85; sensitivity 79, 70, and 81%; specificity 63, 74 and 77%, respectively. DISCUSSION: Individual NCS parameters or their simple combinations are valid measures for identification and future prediction of DSP. Further research into the predictive roles of tibial F-wave latencies, peroneal conduction velocity, and sum of conduction velocities as markers of incipient nerve injury is needed to risk-stratify individuals for clinical and research protocols.

  17. Deficiency in monocarboxylate transporter 1 (MCT1) in mice delays regeneration of peripheral nerves following sciatic nerve crush

    KAUST Repository

    Morrison, Brett M.; Tsingalia, Akivaga; Vidensky, Svetlana; Lee, Youngjin; Jin, Lin; Farah, Mohamed H.; Lengacher, Sylvain; Magistretti, Pierre J.; Pellerin, Luc; Rothsteinb, Jeffrey D.

    2015-01-01

    Peripheral nerve regeneration following injury occurs spontaneously, but many of the processes require metabolic energy. The mechanism of energy supply to axons has not previously been determined. In the central nervous system, monocarboxylate transporter 1 (MCT1), expressed in oligodendroglia, is critical for supplying lactate or other energy metabolites to axons. In the current study, MCT1 is shown to localize within the peripheral nervous system to perineurial cells, dorsal root ganglion neurons, and Schwann cells by MCT1 immunofluorescence in wild-type mice and tdTomato fluorescence in MCT1 BAC reporter mice. To investigate whether MCT1 is necessary for peripheral nerve regeneration, sciatic nerves of MCT1 heterozygous mice are crushed and peripheral nerve regeneration was quantified electrophysiologically and anatomically. Compound muscle action potential (CMAP) recovery is delayed from a median of 21. days in wild-type mice to greater than 38. days in MCT1 heterozygote mice. In fact, half of the MCT1 heterozygote mice have no recovery of CMAP at 42. days, while all of the wild-type mice recovered. In addition, muscle fibers remain 40% more atrophic and neuromuscular junctions 40% more denervated at 42. days post-crush in the MCT1 heterozygote mice than wild-type mice. The delay in nerve regeneration is not only in motor axons, as the number of regenerated axons in the sural sensory nerve of MCT1 heterozygote mice at 4. weeks and tibial mixed sensory and motor nerve at 3. weeks is also significantly reduced compared to wild-type mice. This delay in regeneration may be partly due to failed Schwann cell function, as there is reduced early phagocytosis of myelin debris and remyelination of axon segments. These data for the first time demonstrate that MCT1 is critical for regeneration of both sensory and motor axons in mice following sciatic nerve crush.

  18. Development of pretreatment compounds against nerve-gas agents. Annual report (Final), 16 May 88-30 Sep 90

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, F.I.; Abraham, P.

    1990-09-30

    The U. S. Army Medical Research and Development Command is interested in research directed toward the development of countermeasures to chemical warfare (CW) agents such as the nerve gas poison soman. Soman and other nerve gas poisons are extremely potent cholinesterase inhibitors. This inhibition leads to a buildup of excess acetylcholine resulting in over-stimulation of both the peripheral and central nervous system and can lead to death. Standard therapy for organophosphate nerve agent poisoning is based on co-administration of an anticholinergic agent such as atropine to antagonize the effects of accumulated acetylcholine and a cholinesterase reactivator such as 2-PAM to dephosphorylate the inhibited enzyme. However, since many problems remain in the treatment of organophosphate nerve agent poisoning, there is considerable interest and need to develop new pretreatment and treatment drugs, particularly for soman poisoning.

  19. Incidence and epidemiology of tibial shaft fractures.

    Science.gov (United States)

    Larsen, Peter; Elsoe, Rasmus; Hansen, Sandra Hope; Graven-Nielsen, Thomas; Laessoe, Uffe; Rasmussen, Sten

    2015-04-01

    The literature lacks recent population-based epidemiology studies of the incidence, trauma mechanism and fracture classification of tibial shaft fractures. The purpose of this study was to provide up-to-date information on the incidence of tibial shaft fractures in a large and complete population and report the distribution of fracture classification, trauma mechanism and patient baseline demographics. Retrospective reviews of clinical and radiological records. A total of 196 patients were treated for 198 tibial shaft fractures in the years 2009 and 2010. The mean age at time of fracture was 38.5 (21.2SD) years. The incidence of tibial shaft fracture was 16.9/100,000/year. Males have the highest incidence of 21.5/100,000/year and present with the highest frequency between the age of 10 and 20, whereas women have a frequency of 12.3/100,000/year and have the highest frequency between the age of 30 and 40. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. The majority of tibial shaft fractures occur during walking, indoor activity and sports. The distribution among genders shows that males present a higher frequency of fractures while participating in sports activities and walking. Women present the highest frequency of fractures while walking and during indoor activities. This study shows an incidence of 16.9/100,000/year for tibial shaft fractures. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Software-Engineering Process Simulation (SEPS) model

    Science.gov (United States)

    Lin, C. Y.; Abdel-Hamid, T.; Sherif, J. S.

    1992-01-01

    The Software Engineering Process Simulation (SEPS) model is described which was developed at JPL. SEPS is a dynamic simulation model of the software project development process. It uses the feedback principles of system dynamics to simulate the dynamic interactions among various software life cycle development activities and management decision making processes. The model is designed to be a planning tool to examine tradeoffs of cost, schedule, and functionality, and to test the implications of different managerial policies on a project's outcome. Furthermore, SEPS will enable software managers to gain a better understanding of the dynamics of software project development and perform postmodern assessments.

  1. The Effect of Malrotation of Tibial Component of Total Knee Arthroplasty on Tibial Insert during High Flexion Using a Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Kei Osano

    2014-01-01

    Full Text Available One of the most common errors of total knee arthroplasty procedure is a malrotation of tibial component. The stress on tibial insert is closely related to polyethylene failure. The objective of this study is to analyze the effect of malrotation of tibial component for the stress on tibial insert during high flexion using a finite element analysis. We used Stryker NRG PS for analysis. Three different initial conditions of tibial component including normal, 15° internal malrotation, and 15° external malrotation were analyzed. The tibial insert made from ultra-high-molecular-weight polyethylene was assumed to be elastic-plastic while femoral and tibial metal components were assumed to be rigid. Four nonlinear springs attached to tibial component represented soft tissues around the knee. Vertical load was applied to femoral component which rotated from 0° to 135° while horizontal load along the anterior posterior axis was applied to tibial component during flexion. Maximum equivalent stresses on the surface were analyzed. Internal malrotation caused the highest stress which arose up to 160% of normal position. External malrotation also caused higher stress. Implanting prosthesis in correct position is important for reducing the risk of abnormal wear and failure.

  2. Reconstrucción tibial: transferencia sóleo-peroné ipsilateral. Tibialización peroneal Tibial reconstruction: ipsilateral soleus-fibula transfer. Fibular tibialization

    Directory of Open Access Journals (Sweden)

    E. Revelo Jiron

    2009-12-01

    Full Text Available Las transferencias óseas peroneales en forma libre o ipsilateral han sido propuestas para la reconstrucción de grandes defectos tibiales. Están también descritas varias modificaciones al respecto, siendo una de ellas la constitución de un colgajo compuesto soleo-peroné realizado como transferencia libre. En este estudio presentamos nuestra experiencia con esta variante, pero en forma ipsilateral. logrando la reconstrucción del defecto tibial por medio de la tibialización peroneal. Escogimos realizar un colgajo compuesto soleo-peroné ipsilateral a flujo anterógrado o retrogrado para la reconstrucción de una serie personal de 14 pacientes consecutivos, 13 hombre y 1 mujer, con edad media de 30 años, y con amplios defectos tibiales y de tejidos blandos causados por accidentes de transito en 12 casos, 1 por proyectil balístico y 1 por artefacto explosivo artesanal. El promedio de tamaño del defecto tibial fue de 9.4 cm. Elegimos la forma ipsilateral por no disponer de infraestructura adecuada para realizar una transferencia libre. La serie de estudio se realizó durante el periodo comprendido entre Abril de 1995 y Abril del 2005. Todos los colgajos sobrevivieron. Dos pacientes desarrollaron pseudoartrosis. El apoyo completo y la marcha en 12 pacientes, se logró en un periodo promedio de 9 meses. El seguimiento postoperatorio ha sido de 3 a 6 años. Doce pacientes se han incorporado a la vida activa. Discutimos algunos aspectos prácticos de la técnica como resultado de la experiencia quirúrgica obtenida de esta serie personal. Consideramos que el método es fiable, fácil de realizar y proporciona excelentes resultados.Fibular flaps such as in there free form or as ipsilateral transfers have been proposed for reconstruction of large tibial defects. Several modifications have been described for the use of this flap. In this study we will present our experience using the ipsilateral transfer of an osteomuscular soleous fibular flap

  3. Somatic modulation of spinal reflex bladder activity mediated by nociceptive bladder afferent nerve fibers in cats.

    Science.gov (United States)

    Xiao, Zhiying; Rogers, Marc J; Shen, Bing; Wang, Jicheng; Schwen, Zeyad; Roppolo, James R; de Groat, William C; Tai, Changfeng

    2014-09-15

    The goal of the present study was to determine if supraspinal pathways are necessary for inhibition of bladder reflex activity induced by activation of somatic afferents in the pudendal or tibial nerve. Cats anesthetized with α-chloralose were studied after acute spinal cord transection at the thoracic T9/T10 level. Dilute (0.25%) acetic acid was used to irritate the bladder, activate nociceptive afferent C-fibers, and trigger spinal reflex bladder contractions (amplitude: 19.3 ± 2.9 cmH2O). Hexamethonium (a ganglionic blocker, intravenously) significantly (P reflex bladder contractions to 8.5 ± 1.9 cmH2O. Injection of lidocaine (2%, 1-2 ml) into the sacral spinal cord or transection of the sacral spinal roots and spinal cord further reduced the contraction amplitude to 4.2 ± 1.3 cmH2O. Pudendal nerve stimulation (PNS) at frequencies of 0.5-5 Hz and 40 Hz but not at 10-20 Hz inhibited reflex bladder contractions, whereas tibial nerve stimulation (TNS) failed to inhibit bladder contractions at all tested frequencies (0.5-40 Hz). These results indicate that PNS inhibition of nociceptive afferent C-fiber-mediated spinal reflex bladder contractions can occur at the spinal level in the absence of supraspinal pathways, but TNS inhibition requires supraspinal pathways. In addition, this study shows, for the first time, that after acute spinal cord transection reflex bladder contractions can be triggered by activating nociceptive bladder afferent C-fibers using acetic acid irritation. Understanding the sites of action for PNS or TNS inhibition is important for the clinical application of pudendal or tibial neuromodulation to treat bladder dysfunctions. Copyright © 2014 the American Physiological Society.

  4. Flash photolysis and pulse radiolysis of the Co(sep)3+-X- (sep = sepulchrate; X = I, Br) systems in aqueous solution

    International Nuclear Information System (INIS)

    Pina, F.; Maestri, M.; Ballardini, R.; Mulazzani, Q.G.; D'Angelantonio, M.; Balzani, V.

    1986-01-01

    The Co(sep) 3+ complex (sep = sepulchrate = 1,3,6,8,10,13,16,19-octaazabicyclo[6.6.6]eicosane) in aqueous solution forms ion pairs with the I - and Br - anions, which exhibit a relatively intense charge-transfer absorption. In deoxygenated aqueous solution no net reaction is obtained upon continuous light excitation in the ion-pair charge-transfer bands, but formation of transient species is observed in flash photolysis experiments. For the Co(sep) 3+ -I - system, I 2 - ions are formed that decay in the 50-μs time scale to give I 3 - . The latter species disappears in a time scale of seconds, leading the system back to the preexcitation conditions. For the Co(sep) 3+ -Br - system, only formation of the Br 2 - transient is observed, followed by regeneration of the preexcitation conditions in the 20-μs time scale. In order to elucidate the kinetic aspects of the transient formation and disappearance, pulse radiolysis experiments on the Co(sep) 3+ -I - and Co(sep) 3+ -Br - systems have been carried out. The rate constants of the reactions of Co(sep) 2+ with I 2 - , I 3 - , and Br 2 - have been measured, and a complete picture of the redox processes that follow flash photolysis and pulse radiolysis excitations has been obtained. 5 figures

  5. Continuous EEG-SEP monitoring in severe brain injury.

    Science.gov (United States)

    Amantini, A; Fossi, S; Grippo, A; Innocenti, P; Amadori, A; Bucciardini, L; Cossu, C; Nardini, C; Scarpelli, S; Roma, V; Pinto, F

    2009-04-01

    To monitor acute brain injury in the neurological intensive care unit (NICU), we used EEG and somatosensory evoked potentials (SEP) in combination to achieve more accuracy in detecting brain function deterioration. Sixty-eight patients (head trauma and intracranial hemorrhage; GCSSEP and intracranial pressure monitoring (ICP). Fifty-five patients were considered "stable" or improving, considering the GCS and CT scan: in this group, SEP didn't show significant changes. Thirteen patients showed neurological deteriorations and, in all patients, cortical SEP showed significant alterations (amplitude decrease>50% often till complete disappearance). SEP deterioration anticipated ICP increase in 30%, was contemporary in 38%, and followed ICP increase in 23%. Considering SEP and ICP in relation to clinical course, all patients but one with ICP less than 20 mmHg were stable, while the three patients with ICP greater than 40 mmHg all died. Among the 26 patients with ICP of 20-40 mmHg, 17 were stable, while nine showed clinical and neurophysiological deterioration. Thus, there is a range of ICP values (20-40 mmHg) were ICP is scarcely indicative of clinical deterioration, rather it is the SEP changes that identify brain function deterioration. Therefore, SEP have a twofold interest with respect to ICP: their changes can precede an ICP increase and they can constitute a complementary tool to interpret ICP trends. It has been very important to associate SEP and EEG: about 60% of our patients were deeply sedated and, because of their relative insensitivity to anesthetics, only SEP allowed us to monitor brain damage evolution when EEG was scarcely valuable. We observed 3% of nonconvulsive status epilepticus compared to 18% of neurological deterioration. If the aim of neurophysiological monitoring is to "detect and protect", it may not be limited to detecting seizures, rather it should be able to identify brain deterioration, so we propose the combined monitoring of EEG with SEP.

  6. Nerve ultrasound normal values - Readjustment of the ultrasound pattern sum score UPSS.

    Science.gov (United States)

    Grimm, Alexander; Axer, Hubertus; Heiling, Bianka; Winter, Natalie

    2018-07-01

    Reference values are crucial for nerve ultrasound. Here, we reevaluated normal nerve and fascicle cross-sectional area (CSA) values in humans and compared them to published values. Based on these data, ultrasound pattern sum score (UPSS) boundary values were revisited and readjusted. Ultrasound of different peripheral nerves was performed in 100 healthy subjects at anatomically defined landmarks. Correlations with age, gender, height and weight were calculated. Overall, correspondence to other published reference values was high. Gender-dependency was found for the proximal median nerve. Dependency from height occurred in the tibial nerve (TN). Weight-dependency was not found. However, the most obvious differences were found in the TN between men >60 years and women values were defined using the mean plus the twofold standard deviation for all subjects and nerve segments except for the TN, in which different cut-offs were proposed for elder men. Accordingly, the cut-offs for the UPSS were re-adjusted, none of the individuals revealed more than 2 points at maximum. The influence of distinct epidemiological factors on nerve size is most prominent in the TN, for which thus several normal values are useful. Adjusted reference values improve the accuracy of the UPSS. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  7. SEP-Kr and SEP-Xe in Lunar Ilmenite and the Ar/Kr/Xe Ratio in the Solar Wind

    Science.gov (United States)

    Wieler, R.; Baur, H.; Signer, P.

    1992-07-01

    We analyzed all five noble gases in an ilmenite sample from lunar soil 71501 by closed system stepped etching (CSSE), thus extending our CSSE studies of solar noble gases (Wieler et al., 1986; Benkert et al., 1988) to Kr and Xe. He, Ne, Ar isotopes: We observe the familiar presence of two solar noble gas components: step 1 shows ^4He/^3He = 2250, ^20Ne/^22Ne = 13.8, and ^36Ar/^38Ar=5.46. The first two ratios are essentially identical to modern solar wind values (SWC; Geiss, 1973), indicating an isotopically unfractionated SW noble gas reservoir in lunar ilmenite. The Ne data-points of later steps fall on a straight line and reach the SEP-Ne point (^20Ne/^22Ne = 11.3). The slope of this line indicates mass dependent fractionation between SW-Ne and SEP-Ne. SEP-He (^4He/^3He = 4650 +-100) and SEP-Ar (^36Ar/^38Ar = 4.89+-0.05) are also observed (latter two numbers slightly revised compared to Wieler et al., 1992). Kr, Xe isotopes: Kr in those two steps that release pure SW-Ne is very slightly lighter than atmospheric Kr (^86Kr/^84Kr = 0.3041; see also Wieler et al., 1992). We interpret this to be SW-Kr in soil 71501. Steps containing (isotopically heavier) SEP-Ne likewise release heavier Kr, interpreted accordingly as SEP-Kr (^86Kr/^84Kr = 0.323). Similarly, a light Xe component is released first (SW-Xe, ^136Xe/^132Xe = 0.3003), followed by heavier SEP-Xe (^136Xe/^132Xe = 0.319). The data are consistent with both Kr and Xe in SW and SEP components to be related by mass fractionation. The relation first proposed by Benkert et al. (1988) between a ratio R(m(sub)2,m(sub)1) of two isotopes with masses m(sub)2>m(sub)1 in SW and SEP now holds for all five noble gases: (R(sub)SW-R(sub)SEP)/R(sub)SW = (2+-0.13)*(m(sub)2- m(sub)1)/m(sub)2. Since m(sub)2~m(sub)1, this relation may also be written as: R(sub)SEP/R(sub)SW ~ (m(sub)1/m(sub)2)^2 (Geiss and Bochsler, 1991). Element ratios: ^4He/^36Ar and ^20Ne/^36Ar rise from values several times below SWC to essentially SWC ratios in

  8. Roles of the 15-kDa Selenoprotein (Sep15) in Redox Homeostasis and Cataract Development Revealed by the Analysis of Sep 15 Knockout Mice*

    Science.gov (United States)

    Kasaikina, Marina V.; Fomenko, Dmitri E.; Labunskyy, Vyacheslav M.; Lachke, Salil A.; Qiu, Wenya; Moncaster, Juliet A.; Zhang, Jie; Wojnarowicz, Mark W.; Natarajan, Sathish Kumar; Malinouski, Mikalai; Schweizer, Ulrich; Tsuji, Petra A.; Carlson, Bradley A.; Maas, Richard L.; Lou, Marjorie F.; Goldstein, Lee E.; Hatfield, Dolph L.; Gladyshev, Vadim N.

    2011-01-01

    The 15-kDa selenoprotein (Sep15) is a thioredoxin-like, endoplasmic reticulum-resident protein involved in the quality control of glycoprotein folding through its interaction with UDP-glucose:glycoprotein glucosyltransferase. Expression of Sep15 is regulated by dietary selenium and the unfolded protein response, but its specific function is not known. In this study, we developed and characterized Sep15 KO mice by targeted removal of exon 2 of the Sep15 gene coding for the cysteine-rich UDP-glucose:glycoprotein glucosyltransferase-binding domain. These KO mice synthesized a mutant mRNA, but the shortened protein product could be detected neither in tissues nor in Sep15 KO embryonic fibroblasts. Sep15 KO mice were viable and fertile, showed normal brain morphology, and did not activate endoplasmic reticulum stress pathways. However, parameters of oxidative stress were elevated in the livers of these mice. We found that Sep15 mRNA was enriched during lens development. Further phenotypic characterization of Sep15 KO mice revealed a prominent nuclear cataract that developed at an early age. These cataracts did not appear to be associated with severe oxidative stress or glucose dysregulation. We suggest that the cataracts resulted from an improper folding status of lens proteins caused by Sep15 deficiency. PMID:21768092

  9. TIBIAL PERIPROSTHETIC FRACTURE COMBINED WITH TIBIAL STEM STRESS FRACTURE FROM TOTAL KNEE ARTHROPLASTY

    OpenAIRE

    Fonseca, Fernando; Rebelo, Edgar; Completo, Antonio

    2011-01-01

    Total knee arthroplasty complications related to the prosthetic material are very rare, except for polyethylene wear. We report the case of a 58-year-old woman who came to the emergency service of our hospital with a periprosthetic tibial fracture (Mayo Clinic type I). Careful examination showed that this fracture was concomitantly associated with a tibial stem fatigue fracture. The prosthesis and the stem were sent to an independent biomechanics laboratory for evaluation. A finite-element CA...

  10. Origem e distribuição do nervo isquiático no veado-catingueiro (Mazama gouazoubira Origin and distribution of the sciatic nerve in catingueiro-deer (Mazama gouazoubira

    Directory of Open Access Journals (Sweden)

    Tracy Martina M. Martins

    2013-02-01

    úteo superficial, gluteobíceps, bíceps da coxa, semitendinoso, semimembranoso, adutor e gastrocnêmio. Distalmente o nervo isquiático bifurca-se Em nervo tibial e fibular comum, os quais inervam a porção distal do membro pélvico.This study aimed to describe the origin and distribution of the sciatic nerve in catingueiro-deer (Mazama gouazoubira. Two animals of the species, obtained post mortem by trampling on the highway, were used for the study meeting the requirements of the Governing Law (1.153/95. By dissection the skin was completely removed and the animals were fixed in aqueous 10% formaldehyde solution. Through dorsolateral access, superficial gluteal muscle, biceps femoris muscle and gluteus medius muscle were cut at their insertion and folded, to view the origin and distribution of the sciatic nerve on both sides of the animals. Images were recorded with a digital camera (Sony a200 Camera, 10.2mpx and results were described based on Veterinary Anatomical Nomina. The source data of the sciatic nerve in both specimens showed that the nerve originates from the ventral branches of S1 and L6, and could have contribution from S2. After its emergence through the greater sciatic foramen on both the sides, the sciatic nerve supplies branches to gluteus medius muscle, gluteus deep muscle, superficial gluteal muscle, gluteobiceps muscle, biceps femoris muscle, semimembranosus muscle, semitendinosus muscle and gastrocnemius muscle. Near the mid-thigh the sciatic nerve divides into the tibial nerve and common peroneal nerve which innervate the muscles of the distal hind limb. Moreover, the cutaneous nerve flow can cause the common peroneal nerve or tibial nerve. In conclusion, in Mazama gouazoubira specimens studied, the sciatic nerve originated from the ventral branch of spinal L6 and S1, which may or may not have the contribution from S2. In its distribution stem originate the gluteal nerve, the caudal femoral cutaneous nerve and muscular branches, which together innervate the

  11. In vitro incorporation of (U-C/sup 14/)-glucose and (1-C/sup 14/)-sodium acetate in peripheral nerves of malnourished young rhesus monkeys

    Energy Technology Data Exchange (ETDEWEB)

    Rana, S V; Mehta, S; Chopra, J S; Nain, C K; Mehta, J; Dhand, U K

    1984-01-01

    The effect of protein calorie malnutrition (PCM) on synthesis of lipids in peripheral nerves was studied by in vitro incorporation of (U-C/sup 14/)-glucose and (1-C/sup 14/)-sodium acetate. Ulnar and tibial nerves obtained from five young rhesus monkeys with PCM, five rehabilitated monkeys, and five control monkeys were incubated for 2 h with the radioactive precursors. Uptake of both radioactive precursors in whole peripheral nerves as well as myelin marker lipids was significantly decreased in animals with PCM. However, uptake returned to normal in rehabilitated monkeys.

  12. Radiographic quantitative assessment of cranial tibial subluxation before and after tibial plateau leveling osteotomy in dogs.

    Science.gov (United States)

    Kim, Stanley E; Lewis, Daniel D; Pozzi, Antonio; Seibert, Rachel L; Winter, Matthew D

    2011-03-01

    To determine the influence of stifle joint flexion angle, cranial cruciate ligament (CrCL) integrity, tibial plateau leveling osteotomy (TPLO), and cranial tibial subluxation on the distance between the location of the origin and insertion of the CrCL (CrCL(d)) in dogs. 4 pairs of pelvic limbs from adult dog cadavers weighing 23 to 34 kg. Procedures-Mediolateral projection radiographs of each stifle joint were obtained with the joint flexed at 90°, 105°, 120°, 135°, and 150°. Radiopaque markers were then placed at the sites of origin and insertion of the CrCL. Afterward, radiography was repeated in the same manner, before and after CrCL transection, with and without TPLO. Following CrCL transection, radiographs were obtained before and after inducing overt cranial tibial subluxation. Interobserver variation in measuring the CrCL(d) without fiduciary markers was assessed. The effect of CrCL integrity, cranial tibial subluxation, flexion angle, and TPLO on CrCL(d) was also determined. Interobserver agreement was strong, with an intraclass correlation coefficient of 0.859. The CrCL(d) was significantly shorter (Cranial tibial subluxation caused a 25% to 40% increase in CrCL(d). No effect of TPLO on CrCL(d) was found, regardless of CrCL integrity, forced stifle joint subluxation, or flexion angle. Overt cranial tibial subluxation in CrCL-deficient stifle joints can be detected on mediolateral projection radiographs by comparing CrCL(d) on neutral and stressed joint radiographs at joint angles between 105° and 150°, regardless of whether a TPLO has been performed.

  13. Reduced Renshaw Recurrent Inhibition after Neonatal Sciatic Nerve Crush in Rats

    Directory of Open Access Journals (Sweden)

    Liang Shu

    2014-01-01

    Full Text Available Renshaw recurrent inhibition (RI plays an important gated role in spinal motion circuit. Peripheral nerve injury is a common disease in clinic. Our current research was designed to investigate the change of the recurrent inhibitory function in the spinal cord after the peripheral nerve crush injury in neonatal rat. Sciatic nerve crush was performed on 5-day-old rat puppies and the recurrent inhibition between lateral gastrocnemius-soleus (LG-S and medial gastrocnemius (MG motor pools was assessed by conditioning monosynaptic reflexes (MSR elicited from the sectioned dorsal roots and recorded either from the LG-S and MG nerves by antidromic stimulation of the synergist muscle nerve. Our results demonstrated that the MSR recorded from both LG-S or MG nerves had larger amplitude and longer latency after neonatal sciatic nerve crush. The RI in both LG-S and MG motoneuron pools was significantly reduced to virtual loss (15–20% of the normal RI size even after a long recovery period upto 30 weeks after nerve crush. Further, the degree of the RI reduction after tibial nerve crush was much less than that after sciatic nerve crush indicatig that the neuron-muscle disconnection time is vital to the recovery of the spinal neuronal circuit function during reinnervation. In addition, sciatic nerve crush injury did not cause any spinal motor neuron loss but severally damaged peripheral muscle structure and function. In conclusion, our results suggest that peripheral nerve injury during neonatal early development period would cause a more sever spinal cord inhibitory circuit damage, particularly to the Renshaw recurrent inhibition pathway, which might be the target of neuroregeneration therapy.

  14. Recent Progress on Understanding SEP Acceleration and Transport

    Science.gov (United States)

    Cohen, C.

    2017-12-01

    Joint observations between near-Earth spacecraft and the twin STEREO spacecraft have allowed new examinations of the longitudinal extent of solar energetic particles (SEPs). Although the radial dependence will not be measured in detail until Parker Solar Probe and Solar Orbiter have launched, recent developments in modeling SEP acceleration and transport have revealed interesting dependences on magnetic field configurations and the characteristics of seed particle populations. This talk will review recent SEP in-situ observations along with theoretical studies and their implications for our understanding of SEP acceleration and transport in the inner heliosphere and our expectations for upcoming Solar Orbiter and Parker Solar Probe observations.

  15. A Case Study Of Dietary Deficiency On Peripheral Nerve Functions In Chronic Alcoholic Patient

    Directory of Open Access Journals (Sweden)

    Arbind Kumar Choudhary

    2015-08-01

    Full Text Available Abstract Alcoholic neuropathy is most likely result of dietary deficiency rather than direct neurotoxic effect of alcohol. A male alcoholic patient aged 34- years old with clear clinical sign of peripheral neuropathy was examined after his habit of six years chronic alcoholic drinking. Conduction velocities latencies and nerve action potential amplitudes was measured from median radial common peroneal and sural nerves on respective upper and lower limb and the results showed that there was decrease in conduction velocity of common peroneal and posterior tibial in lower limbs. However sensory nerve conduction SNCV of sural nerve right and left was normal in lower limb. Based on the results observed in our study we conclude that the combination of vitamin B12 uridine and cytidine can be safe and effective in the treatment of patients presenting alcoholic polyneuropathy. So the prognosis of alcoholic peripheral neuropathy is good and independent of age provided that intake of alcohol is withdrawn completely.

  16. Preserving the PCL during the tibial cut in total knee arthroplasty.

    Science.gov (United States)

    Cinotti, G; Sessa, P; Amato, M; Ripani, F R; Giannicola, G

    2017-08-01

    Previous studies have shown that the PCL insertion may be damaged during the tibial cut performed in total knee arthroplasty. We investigated the maximum thickness of a tibial cut that preserves the PCL insertion and to what extent the posterior slope of the tibial cut and that of the patient's tibial plateaus affect the outcome. MR images of 83 knees were analysed. The maximum thickness of a tibial cut that preserves the PCL using a posterior slope of 0°, 3°, 5° and parallel to the patient's slope of the tibial plateau, was evaluated. Correlations between the results and the degrees of the posterior slope of the patient's tibial plateaus were also investigated. The maximum thickness of a tibial cut that preserves the entire PCL insertion was, on average, 5.5, 4.7, 4.2 and 3.1 mm when a posterior slope of 0°, 3°, 5° and parallel to the patients' tibial plateaus was used, respectively. When the 25th percentile was considered, the maximum thickness of a tibial cut that preserved the PCL was 4 and 3 mm with a tibial cut of 0° and 5° of posterior slope, respectively. The maximum thickness of a tibial cut that preserved the PCL was significantly greater in patients with a sagittal slope of the tibial plateaus more than 8° than in those with a sagittal slope less than 8°. In cruciate retaining implants, the PCL insertion may be spared in the majority of patients by performing a tibial cut of 4 mm, or even less when a posterior slope of 3°-5° is used. The clinical relevance of our study is that the execution of a conservative tibial cut, followed by a second tibial resection to achieve the thickness required for the tibial component to be implanted, may be an alternative technique to spare the PCL in CR TKA. II.

  17. Bypass grafting to the anterior tibial artery.

    Science.gov (United States)

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  18. TIBIAL LANDMARKS IN ACL ANATOMIC REPAIR

    Directory of Open Access Journals (Sweden)

    M. V. Demesсhenko

    2016-01-01

    Full Text Available Purpose: to identify anatomical landmarks on tibial articular surface to serve as reference in preparing tibial canal with respect to the center of ACL footprint during single bundle arthroscopic repair.Materials and methods. Twelve frozen knee joint specimens and 68 unpaired macerated human tibia were studied using anatomical, morphometric, statistical methods as well as graphic simulation.Results. Center of the tibial ACL footprint was located 13,1±1,7 mm anteriorly from posterior border of intercondylar eminence, at 1/3 of the distance along the line connecting apexes of internal and external tubercles and 6,1±0,5 mm anteriorly along the perpendicular raised to this point.Conclusion. Internal and external tubercles, as well as posterior border of intercondylar eminence can be considered as anatomical references to determine the center of the tibial ACL footprint and to prepare bone canals for anatomic ligament repair.

  19. Physeal growth arrest after tibial lengthening in achondroplasia

    Science.gov (United States)

    2012-01-01

    Background and purpose Bilateral tibial lengthening has become one of the standard treatments for upper segment-lower segment disproportion and to improve quality of life in achondroplasia. We determined the effect of tibial lengthening on the tibial physis and compared tibial growth that occurred at the physis with that in non-operated patients with acondroplasia. Methods We performed a retrospective analysis of serial radiographs until skeletal maturity in 23 achondroplasia patients who underwent bilateral tibial lengthening before skeletal maturity (lengthening group L) and 12 achondroplasia patients of similar height and age who did not undergo tibial lengthening (control group C). The mean amount of lengthening of tibia in group L was 9.2 cm (lengthening percentage: 60%) and the mean age at the time of lengthening was 8.2 years. The mean duration of follow-up was 9.8 years. Results Skeletal maturity (fusion of physis) occurred at 15.2 years in group L and at 16.0 years in group C. The actual length of tibia (without distraction) at skeletal maturity was 238 mm in group L and 277 mm in group C (p = 0.03). The mean growth rates showed a decrease in group L relative to group C from about 2 years after surgery. Physeal closure was most pronounced on the anterolateral proximal tibial physis, with relative preservation of the distal physis. Interpretation Our findings indicate that physeal growth rate can be disturbed after tibial lengthening in achondroplasia, and a close watch should be kept for such an occurrence—especially when lengthening of more than 50% is attempted. PMID:22489887

  20. Type III Radio Burst Duration and SEP Events

    Science.gov (United States)

    Gopalswamy, N.; Makela, P.; Xie, H.

    2010-01-01

    Long-duration (>15 min), low-frequency (25 MeV. The 1-MHz duration of the type III burst (28 rein) is near the median value of type III durations found for gradual SEP events and ground level enhancement (GLE) events. Yet, there was no sign of SEP events. On the other hand, two other type III bursts from the same active region had similar duration but accompanied by WAVES type 11 bursts; these bursts were also accompanied by SEP events detected by SOHO/ERNE. This study suggests that the type III burst duration may not be a good indicator of an SEP event, consistent with the statistical study of Cliver and Ling (2009, ApJ ).

  1. Asynchronous recruitment of low-threshold motor units during repetitive, low-current stimulation of the human tibial nerve

    Directory of Open Access Journals (Sweden)

    Jesse eDean

    2014-12-01

    Full Text Available Motoneurons receive a barrage of inputs from descending and reflex pathways. Much of our understanding about how these inputs are transformed into motor output in humans has come from recordings of single motor units during voluntary contractions. This approach, however, is limited because the input is ill-defined. Herein, we quantify the discharge of soleus motor units in response to well-defined trains of afferent input delivered at physiologically-relevant frequencies. Constant frequency stimulation of the tibial nerve (10-100 Hz for 30 s, below threshold for eliciting M-waves or H-reflexes with a single pulse, recruited motor units in 7/9 subjects. All 25 motor units recruited during stimulation were also recruited during weak (<10% MVC voluntary contractions. Higher frequencies recruited more units (n=3/25 at 10 Hz; n=25/25 at 100 Hz at shorter latencies (19.4±9.4 s at 10 Hz; 4.1±4.0 s at 100 Hz than lower frequencies. When a second unit was recruited, the discharge of the already active unit did not change, suggesting that recruitment was not due to increased synaptic drive. After recruitment, mean discharge rate during stimulation at 20 Hz (7.8 Hz was lower than during 30 Hz (8.6 Hz and 40 Hz (8.4 Hz stimulation. Discharge was largely asynchronous from the stimulus pulses with time-locked discharge occurring at an H-reflex latency with only a 24% probability. Motor units discharged after the stimulation ended in 89% of trials, although at a lower rate (5.8 Hz than during the stimulation (7.9 Hz. This work supports the idea that the afferent volley evoked by repetitive stimulation recruits motor units through the integration of synaptic drive and intrinsic properties of motoneurons, resulting in physiological recruitment which adheres to Henneman's size principle and results in relatively low discharge rates and asynchronous firing.

  2. Anterior cruciate ligament reconstruction with tibial attachment preserving hamstring graft without implant on tibial side

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2018-01-01

    Full Text Available Background: Tibial attachment preserving hamstring graft could prevent potential problems of free graft in anterior cruciate ligament (ACL reconstruction such as pull out before graft-tunnel healing or rupture before ligamentization. Different implants have been reportedly used for tibial side fixation with this technique. We investigated short-term outcome of ACL reconstruction (ACLR with tibial attachment sparing hamstring graft without implant on the tibial side by outside in technique. Materials and Methods: Seventy nine consecutive cases of ACL tear having age of 25.7 ± 6.8 years were included after Institutional Board Approval. All subjects were male. The mean time interval from injury to surgery was of 7.5 ± 6.4 months. Hamstring tendons were harvested with open tendon stripper leaving the tibial insertion intact. The free ends of the tendons were whip stitched, quadrupled, and whip stitched again over the insertion site of hamstring with fiber wire (Arthrex. Single bundle ACLR was done by outside in technique and the femoral tunnel was created with cannulated reamer. The graft was pulled up to the external aperture of femoral tunnel and fixed with interference screw (Arthrex. The scoring was done by Lysholm, Tegner, and KT 1000 by independent observers. All cases were followed up for 2 years. Results: The mean length of quadrupled graft attached to tibia was 127.65 ± 7.5 mm, and the mean width was 7.52 ± 0.78 mm. The mean preoperative Lysholm score of 47.15 ± 9.6, improved to 96.8 ± 2.4 at 1 year. All cases except two returned to the previous level of activity after ACLR. There was no significant difference statistically between preinjury (5.89 ± 0.68 and postoperative (5.87 ± 0.67 Tegner score. The anterior tibial translation (ATT (KT 1000 improved from 11.44 ± 1.93 mm to 3.59 ± 0.89 mm. The ATT of operated knee returned to nearly the similar value as of the opposite knee (3.47 ± 1.16 mm. The Pivot shift test was negative in

  3. Motor and sensory responses after percutaneous tibial nerve stimulation in multiple sclerosis patients with lower urinary tract symptoms treated in daily practice.

    Science.gov (United States)

    Zecca, C; Digesu, G A; Robshaw, P; Puccini, F; Khullar, V; Tubaro, A; Gobbi, C

    2014-03-01

    Posterior tibial nerve stimulation (PTNS) is an effective treatment option for lower urinary tract symptoms (LUTS) in multiple sclerosis (MS) patients. Patients with MS and LUTS unresponsive to medical treatment received PTNS for 12 weeks after saline urodynamics to evaluate the prevalence of motor, sensory and combined responses during PTNS and to determine whether the type of response can predict treatment outcome. LUTS were also assessed using a 3-day bladder diary, patient perception of bladder condition (PPBC) questionnaire, patient perception of intensity of urgency scale (PPIUS), Kings Health QOL questionnaire (KHQ) and Overactive Bladder Questionnaire (OAB-q) before and after treatment. Patients were considered as "responders" if they reported an improvement >50% in their LUTS according to the PPBC. Sensory, motor and combined sensory/motor responses were compared between responders and non-responders. Eighty-three patients were included. 61% (51/83) of patients were responders. Sensory, motor and combined sensory/motor responses were found in 64% (53/83), 6% (5/83) and 30% (25/83) of patients respectively. A sensory response alone, or in combination with a motor response, was better associated with a successful outcome than the presence of a motor response alone (P = 0.001). A sensory response, either alone or in combination with a motor response, is more frequent and seems to be better associated with a successful outcome of PTNS than motor response alone. © 2014 The Author(s) European Journal of Neurology © 2014 EFNS.

  4. 76 FR 55741 - Proposed Collection; Comment Request for Form 5305-SEP

    Science.gov (United States)

    2011-09-08

    ... 5305-SEP AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... Form 5305-SEP, Simplified Employee Pension-Individual Retirement Accounts Contribution Agreement. DATES...: 5305-SEP. Abstract: Form 5305-SEP is used by an employer to make an agreement provide benefits to all...

  5. The tibial nerve compression test for the diagnosis of lumbar spinal canal stenosis-A simple and reliable physical examination for use by primary care physicians.

    Science.gov (United States)

    Adachi, Shu; Nakano, Atsushi; Kin, Akihiro; Baba, Ichiro; Kurokawa, Yoshitaka; Neo, Masashi

    2018-01-01

    In the present study, we aimed to evaluate the diagnostic accuracy and suitability of the 'Tibial Nerve Compression Test (TNCT)' as a screening tool for lumbar spinal canal stenosis (LSS). A total of 108 consecutive patients admitted to our hospital for surgical treatment or diagnosis of LSS were included in this study. Fifty healthy volunteers were examined as a control group. The severity of tenderness was scored (tenderness score) and measured on a visual analogue scale (P-VAS score). These scores were compared between the LSS and control groups. Moreover, they were compared before and after the operation among operated patients. The positive tenderness rate was significantly higher (92.6% [100/108]) in the LSS group than in the control group (30% [15/50]). The sensitivity and specificity of TNCT (95% confidence interval) were 0.93 (0.88-0.96) and 0.70 (0.61-0.77), respectively. Positive tenderness rates and P-VAS scores were significantly higher in the LSS group (p Test is a useful screening tool for LSS diagnosis in a primary care setting. Level II, diagnostic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  6. Lifecourse SEP and tobacco and cannabis use.

    Science.gov (United States)

    Bowes, Lucy; Chollet, Aude; Fombonne, Eric; Galéra, Cédric; Melchior, Maria

    2013-04-01

    Social inequalities in substance use have been well-documented; however, the impact of changes in socio-economic position from childhood to adulthood is unclear. We examined the relationship between intergenerational trajectories of social position and tobacco and cannabis use among young adults. Data come from 1103 participants (mean age: 28.9 years) of the Trajectoires Epidémiologiques en Population (TEMPO) study and their parents, participants of the GAZEL study, France. Multinomial regression analyses were used to examine associations between lifecourse socio-economic position (SEP) assessed using the parent's reports of family income (1989 and 2002) and the participant's educational attainment, occupational grade and job stability in 2009, with self-reported tobacco and cannabis use in 2009. Compared with participants with stable intermediate/high SEP, those with stable low SEP and those with declining SEP were more likely to use tobacco (age- and sex-adjusted ORs = 2.03 and 2.26). Participants who experienced declining SEP were also disproportionately likely to use and abuse cannabis (adjusted ORs = 2.22 and 2.73). Associations remained significant after adjusting for family (parental smoking, alcohol use, ill health, unemployment, depression and divorce) and individual (early tobacco and cannabis use, academic difficulties, juvenile internalizing and externalizing problems) risk factors. Cross-sectional studies indicate social inequalities in substance use. Our longitudinal findings suggest that individuals who experienced declining SEP from childhood to adulthood may be twice as likely to use tobacco and cannabis compared with individuals with a stable/high trajectory. Interventions targeting substance abuse should take into account lifecourse determinants including the interplay between individuals' socio-economic origins and later attainment.

  7. SEP Montage Variability Comparison during Intraoperative Neurophysiologic Monitoring.

    Science.gov (United States)

    Hanson, Christine; Lolis, Athena Maria; Beric, Aleksandar

    2016-01-01

    Intraoperative monitoring is performed to provide real-time assessment of the neural structures that can be at risk during spinal surgery. Somatosensory evoked potentials (SEPs) are the most commonly used modality for intraoperative monitoring. SEP stability can be affected by many factors during the surgery. This study is a prospective review of SEP recordings obtained during intraoperative monitoring of instrumented spinal surgeries that were performed for chronic underlying neurologic and neuromuscular conditions, such as scoliosis, myelopathy, and spinal stenosis. We analyzed multiple montages at the baseline, and then followed their development throughout the procedure. Our intention was to examine the stability of the SEP recordings throughout the surgical procedure on multiple montages of cortical SEP recordings, with the goal of identifying the appropriate combination of the least number of montages that gives the highest yield of monitorable surgeries. Our study shows that it is necessary to have multiple montages for SEP recordings, as it reduces the number of non-monitorable cases, improves IOM reliability, and therefore could reduce false positives warnings to the surgeons. Out of all the typical montages available for use, our study has shown that the recording montage Cz-C4/Cz-C3 (Cz-Cc) is the most reliable and stable throughout the procedure and should be the preferred montage followed throughout the surgery.

  8. Roles of the 15-kDa Selenoprotein (Sep15) in Redox Homeostasis and Cataract Development Revealed by the Analysis of Sep 15 Knockout Mice*

    OpenAIRE

    Kasaikina, Marina V.; Fomenko, Dmitri E.; Labunskyy, Vyacheslav M.; Lachke, Salil A.; Qiu, Wenya; Moncaster, Juliet A.; Zhang, Jie; Wojnarowicz, Mark W.; Natarajan, Sathish Kumar; Malinouski, Mikalai; Schweizer, Ulrich; Tsuji, Petra A.; Carlson, Bradley A.; Maas, Richard L.; Lou, Marjorie F.

    2011-01-01

    The 15-kDa selenoprotein (Sep15) is a thioredoxin-like, endoplasmic reticulum-resident protein involved in the quality control of glycoprotein folding through its interaction with UDP-glucose:glycoprotein glucosyltransferase. Expression of Sep15 is regulated by dietary selenium and the unfolded protein response, but its specific function is not known. In this study, we developed and characterized Sep15 KO mice by targeted removal of exon 2 of the Sep15 gene coding for the cysteine-rich UDP-gl...

  9. Relationship between SEP Peak intensity and CME Acceleration, Speed and Width

    Science.gov (United States)

    Xie, H.; St Cyr, O. C.; Makela, P. A.; Gopalswamy, N.

    2017-12-01

    We study the large solar energetic particle (SEP) events that were detected by GOES in the >10 MeV energy channel during December 2006 to January 2016. Data used in this study includes the Solar Electron Proton Telescope (SEPT) and High Energy Telescopes (HET) on STEREO A and B, the Electron, Proton, and Alpha Monitor (EPAM) on ACE, and the Energetic and Relativistic Nuclei and Electron instrument (ERNE) on SOHO. By choosing the smallest connection angles between SEP solar locations and magnetic foot-points of each spacecraft, we divide SEP events as SOHO SEPs or STEREO SEPs. We then compute the SEP peak intensity I0 at the center of the Gausssian using the Gausssian expression from Richardson et al. (2014) and study the relationship between SEP electron and proton peak intensity and CME acceleration, speed and width. By using I0 derived from multi-spacecraft observations we found that the correlations between SEP peak intensity and CME acceleration and speed improved. We also found that this correlation can be further improved by taking into account the effects of CME width and its solar source latitude. The implication for the SEP forecast of our obtained results will be discussed.

  10. Effects of counteracting external valgus moment on lateral tibial cartilage contact conditions and tibial rotation.

    Science.gov (United States)

    Shriram, Duraisamy; Parween, Rizuwana; Lee, Yee Han Dave; Subburaj, Karupppasamy

    2017-07-01

    Knee osteoarthritis that prevalently occurs at the medial compartment is a progressive chronic disorder affecting the articular cartilage of the knee joint, and lead to loss of joint functionality. Valgus braces have been used as a treatment procedure to unload the medial compartment for patients with medial osteoarthritis. Valgus braces through the application of counteracting external valgus moment shift the load from medial compartment towards the lateral compartment. Previous biomechanical studies focused only on the changes in varus moments before and after wearing the brace. The objective of this study was to investigate the influence of opposing external valgus moment applied by knee braces on the lateral tibial cartilage contact conditions using a 3D finite element model of the knee joint. Finite element simulations were performed on the knee joint model without and with the application of opposing valgus moment to mimic the unbraced and braced conditions. Lateral tibial cartilage contact pressures and contact area, and tibial rotation (varus-valgus and internal-external) were estimated for the complete walking gait cycle. The opposing valgus moment increased the maximum contact pressure and contact area on the lateral tibial cartilage compared to the normal gait moment. A peak contact pressure of 8.2 MPa and maximum cartilage loaded area of 28% (loaded cartilage nodes) on the lateral cartilage with the application of external valgus moment were induced at 50% of the gait cycle. The results show that the use of opposing valgus moment may significantly increase the maximum contact pressures and contact area on the lateral tibial cartilage and increases the risk of articular cartilage damage on the lateral compartment.

  11. Bilateral double level tibial lengthening in dwarfism.

    Science.gov (United States)

    Burghardt, Rolf D; Yoshino, Koichi; Kashiwagi, Naoya; Yoshino, Shigeo; Bhave, Anil; Paley, Dror; Herzenberg, John E

    2015-12-01

    Outcome assessment after double level tibial lengthening in patients with dwarfism. Fourteen patients with dwarfism were analyzed after bilateral simultaneous double level tibial lengthening. Average age was 15.1 years. Average lengthening was 13.5 cm. The two levels were lengthened by an average of 7.5 cm proximally and 6.0 cm distally. Concomitant deformities were also addressed during lengthening. External fixation treatment time averaged 8.8 months. Healing index averaged 0.7 months/cm. Bilateral tibial lengthening for dwarfism is difficult, but the results are usually quite gratifying.

  12. Measurement of tibial torsion by computer tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jend, H.H.; Heller, M.; Dallek, M.; Schoettle, H. (Hamburg Univ. (Germany, F.R.))

    1981-01-01

    A CT procedure for objective measurements of tibial torsion independent of axial rotation in the nearby joints is described. Transverse sections in defined planes of the tibia permit easy calculation of normal and abnormal congenital or posttraumatic angles of torsion. In 69 limbs normal tibial torsion was 40/sup 0/+-9/sup 0/. In a series of 42 limbs with complicated healing of a fracture of both bones of the leg it is shown that tibial maltorsion is a deformity which in most cases leads to arthrosis of the ankle joint.

  13. Measurement of tibial torsion by computer tomography

    International Nuclear Information System (INIS)

    Jend, H.-H.; Heller, M.; Dallek, M.; Schoettle, H.

    1981-01-01

    A CT procedure for objective measurements of tibial torsion independent of axial rotation in the nearby joints is described. Transverse sections in defined planes of the tibia permit easy calculation of normal and abnormal congenital or posttraumatic angles of torsion. In 69 limbs normal tibial torsion was 40 0 +-9 0 . In a series of 42 limbs with complicated healing of a fracture of both bones of the leg it is shown that tibial maltorsion is a deformity which in most cases leads to arthrosis of the ankle joint. (Auth.)

  14. A preconditioning nerve lesion inhibits mechanical pain hypersensitivity following subsequent neuropathic injury

    Directory of Open Access Journals (Sweden)

    Wu Ann

    2011-01-01

    Full Text Available Abstract Background A preconditioning stimulus can trigger a neuroprotective phenotype in the nervous system - a preconditioning nerve lesion causes a significant increase in axonal regeneration, and cerebral preconditioning protects against subsequent ischemia. We hypothesized that a preconditioning nerve lesion induces gene/protein modifications, neuronal changes, and immune activation that may affect pain sensation following subsequent nerve injury. We examined whether a preconditioning lesion affects neuropathic pain and neuroinflammation after peripheral nerve injury. Results We found that a preconditioning crush injury to a terminal branch of the sciatic nerve seven days before partial ligation of the sciatic nerve (PSNL; a model of neuropathic pain induced a significant attenuation of pain hypersensitivity, particularly mechanical allodynia. A preconditioning lesion of the tibial nerve induced a long-term significant increase in paw-withdrawal threshold to mechanical stimuli and paw-withdrawal latency to thermal stimuli, after PSNL. A preconditioning lesion of the common peroneal induced a smaller but significant short-term increase in paw-withdrawal threshold to mechanical stimuli, after PSNL. There was no difference between preconditioned and unconditioned animals in neuronal damage and macrophage and T-cell infiltration into the dorsal root ganglia (DRGs or in astrocyte and microglia activation in the spinal dorsal and ventral horns. Conclusions These results suggest that prior exposure to a mild nerve lesion protects against adverse effects of subsequent neuropathic injury, and that this conditioning-induced inhibition of pain hypersensitivity is not dependent on neuroinflammation in DRGs and spinal cord. Identifying the underlying mechanisms may have important implications for the understanding of neuropathic pain due to nerve injury.

  15. SEP modeling based on global heliospheric models at the CCMC

    Science.gov (United States)

    Mays, M. L.; Luhmann, J. G.; Odstrcil, D.; Bain, H. M.; Schwadron, N.; Gorby, M.; Li, Y.; Lee, K.; Zeitlin, C.; Jian, L. K.; Lee, C. O.; Mewaldt, R. A.; Galvin, A. B.

    2017-12-01

    Heliospheric models provide contextual information of conditions in the heliosphere, including the background solar wind conditions and shock structures, and are used as input to SEP models, providing an essential tool for understanding SEP properties. The global 3D MHD WSA-ENLIL+Cone model provides a time-dependent background heliospheric description, into which a spherical shaped hydrodynamic CME can be inserted. ENLIL simulates solar wind parameters and additionally one can extract the magnetic topologies of observer-connected magnetic field lines and all plasma and shock properties along those field lines. An accurate representation of the background solar wind is necessary for simulating transients. ENLIL simulations also drive SEP models such as the Solar Energetic Particle Model (SEPMOD) (Luhmann et al. 2007, 2010) and the Energetic Particle Radiation Environment Module (EPREM) (Schwadron et al. 2010). The Community Coordinated Modeling Center (CCMC) is in the process of making these SEP models available to the community and offering a system to run SEP models driven by a variety of heliospheric models available at CCMC. SEPMOD injects protons onto a sequence of observer field lines at intensities dependent on the connected shock source strength which are then integrated at the observer to approximate the proton flux. EPREM couples with MHD models such as ENLIL and computes energetic particle distributions based on the focused transport equation along a Lagrangian grid of nodes that propagate out with the solar wind. The coupled SEP models allow us to derive the longitudinal distribution of SEP profiles of different types of events throughout the heliosphere. The coupled ENLIL and SEP models allow us to derive the longitudinal distribution of SEP profiles of different types of events throughout the heliosphere. In this presentation we demonstrate several case studies of SEP event modeling at different observers based on WSA-ENLIL+Cone simulations.

  16. [Particular posteromedial and posterolateral approaches for the treatment of tibial head fractures].

    Science.gov (United States)

    Lobenhoffer, P; Gerich, T; Bertram, T; Lattermann, C; Pohlemann, T; Tscheme, H

    1997-12-01

    Tibial plateau fractures with depression of posterior aspects of the proximal tibia cause significant therapeutic problems. Posterior fractures on the medial side are mainly highly instable fracture-dislocations (Moore type I). Posterolateral fractures usually cause massive depression and destruction of the chondral surface. Surgical exposure of these fractures from anterior requires major soft tissue dissection and has a significant complication rate. However, incomplete restoration of the joint surface results in chronic postero-inferior joint subluxation, osteoarthritis and pain. We present new specific approaches for posterior fracture types avoiding large skin incisions, but allowing for atraumatic exposure, reduction and fixation. Posteromedial fracture-dislocations are exposed by a direct posteromedial skin incision and a deep incision between medial collateral ligament and posterior oblique ligament. The posteromedial pillar and the posterior flare of the proximal tibia are visualized. The inferior extent of the joint fragment can be reduced by indirect techniques or direct manipulation of the fragment. Fixation is achieved with subchondral lag screws and an anti-glide plate at the tip of the fragment. Posterolateral fractures are exposed by a transfibular approach: the skin is incised laterally, the peroneal nerve is dissected free. The fibula neck is osteotomized, the tibiofibular syndesmosis is divided and the fibula neck is reflected upwards in one layer with the meniscotibial ligament and the iliotibial tract attachment. Reflexion of the fibula head relaxes the lateral collateral ligament, allows for lateral joint opening and internal rotation of the tibia and thus exposes the posterolateral and posterior aspect of the tibial plateau. Fixation and buttressing on the posterolateral side can be achieved easily with this approach. In closure, the fibula head is fixed back with a lag screw or a tension-band system. These two exposures can be combined in

  17. Incomplete linear tibial fractures in two horses

    International Nuclear Information System (INIS)

    Johnson, P.J.; Allhands, R.V.; Baker, G.J.; Boero, M.J.; Foreman, J.H.; Hyyppa, T.; Huhn, J.C.

    1988-01-01

    Incomplete linear tibial fractures were identified in two horses with the aid of scintigraphy. Both horses were treated successfully by strict stall confinement, and both returned to normal athletic activity. Scintigraphy can be used to facilitate the generally difficult diagnosis of incomplete tibial fractures

  18. Different SEP recovery cycle in adolescent migraineurs with exploding or imploding pain.

    Science.gov (United States)

    Iacovelli, Elisa; Tarantino, Samuela; Capuano, Alessandro; De Luca, Massimiliano; De Ranieri, Cristiana; Vigevano, Federico; Arendt-Nielsen, Lars; Valeriani, Massimiliano

    2013-01-01

    Our aim was to investigate whether migraine adolescents with pain directed inside (imploding pain--IP) and outside (exploding pain--EP) the head may have different levels of cortical excitability underlying their migraineous syndrome. Ten migraine children referring prevalent EP (mean age 14.5 ± 1.4 years, 3 girls, 7 boys), 10 patients with IP (mean age 14.1 ± 2.2 years, 4 girls, 6 boys), and 13 control subjects (mean age 13 ± 1.8 years, 6 males, 7 females) participated to the study. The recovery cycle of the somatosensory evoked potentials to electrical median nerve stimuli at interstimulus intervals of 5, 20, and 40 ms was measured. Anger expression, anxiety, and somatic concerns were investigated in migraine patients. Overall, SEP recovery cycle was shorter in migraineurs than in healthy controls. The recovery cycle of the frontal N30 SEP component was significantly shorter in IP than in EP patients. While among the EP patients those with faster N30 recovery cycle had higher Trait-Anger score, the opposite was found among the IP patients. Our results suggest that the inhibitory mechanisms within the somatosensory cortex are more impaired in IP than in EP migraine adolescents. The pathophysiological difference between IP and EP migraineurs was strengthened also by the opposite correlations between the brain excitability and the anger expression. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  19. Secretion of Growth Hormone in Response to Muscle Sensory Nerve Stimulation

    Science.gov (United States)

    Grindeland, Richard E.; Roy, R. R.; Edgerton, V. R.; Gosselink, K. L.; Grossman, E. J.; Sawchenko, P. E.; Wade, Charles E. (Technical Monitor)

    1994-01-01

    Growth hormone (GH) secretion is stimulated by aerobic and resistive exercise and inhibited by exposure to actual or simulated (bedrest, hindlimb suspension) microgravity. Moreover, hypothalamic growth hormone-releasing factor (GRF) and preproGRF mRNA are markedly decreased in spaceflight rats. These observations suggest that reduced sensory input from inactive muscles may contribute to the reduced secretion of GH seen in "0 G". Thus, the aim of this study was to determine the effect of muscle sensory nerve stimulation on secretion of GH. Fed male Wistar rats (304 +/- 23 g) were anesthetized (pentobarbital) and the right peroneal (Pe), tibial (T), and sural (S) nerves were cut. Electrical stimulation of the distal (D) or proximal (P) ends of the nerves was implemented for 15 min. to mimic the EMG activity patterns of ankle extensor muscles of a rat walking 1.5 mph. The rats were bled by cardiac puncture and their anterior pituitaries collected. Pituitary and plasma bioactive (BGH) and immunoactive (IGH) GH were measured by bioassay and RIA.

  20. The fate of neurotization techniques on reinnervation after denervation of the gastrocnemius muscle: an experimental study.

    Science.gov (United States)

    Askar, I; Sabuncuoglu, B T; Yormuk, E; Saray, A

    2001-07-01

    In nerve injuries, if it is not possible to reinnervate muscle by using neurorrhaphy and nerve grafting technique, reinnervation should be provided by the use of neuroization-directly implanting motor nerve into muscle. A comparative study of three techniques of neurotization is presented in rabbits. In this experimental study, a total of 40 white New Zealand rabbits were used and divided into four groups, each including 10 rabbits. In the first group (control--Group 1), only surgical exposure of the gastrocnemius muscle, main muscle nerve (tibial nerve), and peroneal nerve was done, without any injury to the nerves. In the second group (direct neurotization group--Group 2), the tibial nerve was transected, and the peroneal nerve, which had already been divided into fascicles, was implanted into the lateral head of the gastrocnemius muscle aneural zone. In the third group (dual neurotization group--Group 3), the tibial nerve which had been transected and re-anastomosed, and the peroneal nerve were implanted into the lateral head of the gastrocnemius muscle. In the last experimental group (hyperneurotization group--Group 4), fascicles of the peroneal nerve were implanted into the lateral head of the gastrocnemius, preserving the tibial nerve. Six months later, changes in the histologic pattern and the functional recovery of the gastrocnemius muscle were investigated. It was found that functional recovery was achieved in all neurotization groups. Groups with the tibial nerve transected had less muscular weights than those of groups with the tibial nerve intact. EMG recordings showed that polyphasic and late potentials were frequently seen in groups with the tibial nerve transected. Degeneration and regeneration of myofibrils was observed in such groups as well. New motor end-plates, including vesicles, were formed in a scattered manner in all neurotization groups. As a result, the authors conclude that direct and dual neurotization techniques are useful in peripheral

  1. Incidence and epidemiology of tibial shaft fractures

    DEFF Research Database (Denmark)

    Larsen, Peter; Elsøe, Rasmus; Hansen, Sandra Hope

    2015-01-01

    Introduction: The literature lacks recent population-based epidemiology studies of the incidence, trauma mechanism and fracture classification of tibial shaft fractures. The purpose of this study was to provide up-to-date information on the incidence of tibial shaft fractures in a large....... The mean age at time of fracture was 38.5 (21.2SD) years. The incidence of tibial shaft fracture was 16.9/100,000/year. Males have the highest incidence of 21.5/100,000/year and present with the highest frequency between the age of 10 and 20, whereas women have a frequency of 12.3/100,000/year and have...... frequency of fractures while participating in sports activities and walking. Women present the highest frequency of fractures while walking and during indoor activities. Conclusion: This study shows an incidence of 16.9/100,000/year for tibial shaft fractures. AO-type 42-A1 was the most common fracture type...

  2. Proximal tibial fracture following anterior cruciate ligament reconstruction surgery: a biomechanical analysis of the tibial tunnel as a stress riser.

    Science.gov (United States)

    Aldebeyan, Wassim; Liddell, Antony; Steffen, Thomas; Beckman, Lorne; Martineau, Paul A

    2017-08-01

    This is the first biomechanical study to examine the potential stress riser effect of the tibial tunnel or tunnels after ACL reconstruction surgery. In keeping with literature, the primary hypothesis tested in this study was that the tibial tunnel acts as a stress riser for fracture propagation. Secondary hypotheses were that the stress riser effect increases with the size of the tunnel (8 vs. 10 mm), the orientation of the tunnel [standard (STT) vs. modified transtibial (MTT)], and with the number of tunnels (1 vs. 2). Tibial tunnels simulating both single bundle hamstring graft (8 mm) and bone-patellar tendon-bone graft (10 mm) either STT or MTT position, as well as tunnels simulating double bundle (DB) ACL reconstruction (7, 6 mm), were drilled in fourth-generation saw bones. These five experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure on a Materials Testing System to simulate tibial plateau fracture. There were no statistically significant differences in peak load to failure between any of the groups, including the control group. The fracture occurred through the tibial tunnel in 100 % of the MTT tunnels (8 and 10 mm) and 80 % of the DB tunnels specimens; however, the fractures never (0 %) occurred through the tibial tunnel of the standard tunnels (8 or 10 mm) (P = 0.032). In the biomechanical model, the tibial tunnel does not appear to be a stress riser for fracture propagation, despite suggestions to the contrary in the literature. Use of a standard, more vertical tunnel decreases the risk of ACL graft compromise in the event of a fracture. This may help to inform surgical decision making on ACL reconstruction technique.

  3. Tibial shaft fractures in football players

    Directory of Open Access Journals (Sweden)

    Daisley Susan

    2007-06-01

    Full Text Available Abstract Background Football is officially the most popular sport in the world. In the UK, 10% of the adult population play football at least once a year. Despite this, there are few papers in the literature on tibial diaphyseal fractures in this sporting group. In addition, conflicting views on the nature of this injury exist. The purpose of this paper is to compare our experience of tibial shaft football fractures with the little available literature and identify any similarities and differences. Methods and Results A retrospective study of all tibial football fractures that presented to a teaching hospital was undertaken over a 5 year period from 1997 to 2001. There were 244 tibial fractures treated. 24 (9.8% of these were football related. All patients were male with a mean age of 23 years (range 15 to 29 and shin guards were worn in 95.8% of cases. 11/24 (45.8% were treated conservatively, 11/24 (45.8% by Grosse Kemp intramedullary nail and 2/24 (8.3% with plating. A difference in union times was noted, conservative 19 weeks compared to operative group 23.9 weeks (p Conclusion Our series compared similarly with the few reports available in the literature. However, a striking finding noted by the authors was a drop in the incidence of tibial shaft football fractures. It is likely that this is a reflection of recent compulsory FIFA regulations on shinguards as well as improvements in the design over the past decade since its introduction.

  4. Pseudoarthrosis of medial tibial plateau fracture-role of alignment procedure

    Directory of Open Access Journals (Sweden)

    Devgan Ashish

    2013-04-01

    Full Text Available 【Abstract】 Nonunion in tibial plateau fractures is very rare. Limited literature is available on Pubmed search on intraarticular tibial nonunion. Most of the cases reported have been following failed surgical treatment and none was neglected fractures. Three patients of isolated and neglected medial tibial plateau nonunion with almost similar demo-graphic profile are reported in this paper. All the three pa-tients were managed by minimally invasive compression fixation using lag screws supplemented with limb realign-ment procedure of high tibial osteotomy. We discussed the injury mechanism, management and rehabilitation in such cases and reviewed the available literature regarding such a presentation. Key words: Fracture healing; Tibial fractures; Frac-ture fixation; Osteotomy

  5. Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging.

    Science.gov (United States)

    Karimi, Elham; Norouzian, Mohsen; Birjandinejad, Ali; Zandi, Reza; Makhmalbaf, Hadi

    2017-11-01

    Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which affects knee joint stability. Posterior tibial slope has impact on flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the mechanical and anatomical axis is important. The aim of this study was to evaluate the value of posterior tibial slope in medial and lateral compartments of tibial plateau and to assess the relationship among the slope with age, gender and other variables of tibial plateau surface. This descriptive study was conducted on 132 healthy knees (80 males and 52 females) with a mean age of 38.26±11.45 (20-60 years) at Imam Reza hospital in Mashhad, Iran. All patients, selected and enrolled for MRI in this study, were admitted for knee pain with uncertain clinical history. According to initial physical knee examinations the study subjects were reported healthy. The mean posterior tibial slope was 7.78± 2.48 degrees in the medial compartment and 6.85± 2.24 degrees in lateral compartment. No significant correlation was found between age and gender with posterior tibial slope ( P ≥0.05), but there was significant relationship among PTS with mediolateral width, plateau area and medial plateau. Comparison of different studies revealed that the PTS value in our study is different from other communities, which can be associated with genetic and racial factors. The results of our study are useful to PTS reconstruction in surgeries.

  6. NR2B Expression in Rat DRG Is Differentially Regulated Following Peripheral Nerve Injuries That Lead to Transient or Sustained Stimuli-Evoked Hypersensitivity.

    Science.gov (United States)

    Norcini, Monica; Sideris, Alexandra; Adler, Samantha M; Hernandez, Lourdes A M; Zhang, Jin; Blanck, Thomas J J; Recio-Pinto, Esperanza

    2016-01-01

    Following injury, primary sensory neurons undergo changes that drive central sensitization and contribute to the maintenance of persistent hypersensitivity. NR2B expression in the dorsal root ganglia (DRG) has not been previously examined in neuropathic pain models. Here, we investigated if changes in NR2B expression within the DRG are associated with hypersensitivities that result from peripheral nerve injuries. This was done by comparing the NR2B expression in the DRG derived from two modalities of the spared nerve injury (SNI) model, since each variant produces different neuropathic pain phenotypes. Using the electronic von Frey to stimulate the spared and non-spared regions of the hindpaws, we demonstrated that sural-SNI animals develop sustained neuropathic pain in both regions while the tibial-SNI animals recover. NR2B expression was measured at Day 23 and Day 86 post-injury. At Day 23 and 86 post-injury, sural-SNI animals display strong hypersensitivity, whereas tibial-SNI animals display 50 and 100% recovery from post-injury-induced hypersensitivity, respectively. In tibial-SNI at Day 86, but not at Day 23 the perinuclear region of the neuronal somata displayed an increase in NR2B protein. This retention of NR2B protein within the perinuclear region, which will render them non-functional, correlates with the recovery observed in tibial-SNI. In sural-SNI at Day 86, DRG displayed an increase in NR2B mRNA which correlates with the development of sustained hypersensitivity in this model. The increase in NR2B mRNA was not associated with an increase in NR2B protein within the neuronal somata. The latter may result from a decrease in kinesin Kif17, since Kif17 mediates NR2B transport to the soma's plasma membrane. In both SNIs, microglia/macrophages showed a transient increase in NR2B protein detected at Day 23 but not at Day 86, which correlates with the initial post-injury induced hypersensitivity in both SNIs. In tibial-SNI at Day 86, but not at Day 23

  7. Tibial Eminence Involvement With Tibial Plateau Fracture Predicts Slower Recovery and Worse Postoperative Range of Knee Motion.

    Science.gov (United States)

    Konda, Sanjit R; Driesman, Adam; Manoli, Arthur; Davidovitch, Roy I; Egol, Kenneth A

    2017-07-01

    To examine 1-year functional and clinical outcomes in patients with tibial plateau fractures with tibial eminence involvement. Retrospective analysis of prospectively collected data. Academic Medical Center. All patients who presented with a tibial plateau fracture (Orthopaedic Trauma Association (OTA) 41-B and 41-C). Patients were divided into fractures with a tibial eminence component (+TE) and those without (-TE) cohorts. All patients underwent similar surgical approaches and fixation techniques for fractures. No tibial eminence fractures received fixation specifically. Short musculoskeletal functional assessment (SMFA), pain (Visual Analogue Scale), and knee range-of-motion (ROM) were evaluated at 3, 6, and 12 months postoperatively and compared between cohorts. Two hundred ninety-three patients were included for review. Patients with OTA 41-C fractures were more likely to have an associated TE compared with 41-B fractures (63% vs. 28%, P knee ROM (75.16 ± 51 vs. 86.82 ± 53 degree, P = 0.06). At 6 months, total SMFA and knee ROM was significantly worse in the +TE cohort (29 ± 17 vs. 21 ± 18, P ≤ 0.01; 115.6 ± 20 vs. 124.1 ± 15, P = 0.01). By 12 months postoperatively, only knee ROM remained significantly worse in the +TE cohort (118.7 ± 15 vs. 126.9 ± 13, P time points. Knee ROM remains worse throughout the postoperative period in the +TE cohort. Functional outcome improves less rapidly in the +TE cohort but achieves similar results by 1 year. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Non-formation of the main trunk of the sciatic nerve and unusual relationships to the piriformis muscle

    Directory of Open Access Journals (Sweden)

    J. Stoyanov

    2017-09-01

    Full Text Available Background: The sciatic nerve is the largest branch of the sacral plexus. Variations of its origin, exit from the pelvis, emergence and branching in the posterior region of the thigh, especially in regards to the piriformis muscle, are an object of interest due to the possibility to be involved in the pathogenensis of clinically significant non-discogenic sciatica or piriformis syndrome. Case report: We present a case of variant anatomy of the sciatic nerve, discovered during routine dissection of the left gluteal region of an adult female cadaver. We observed a non-formation of the main trunk of the nerve; rather, the tibial nerve passed inferiorly to the piriformis muscle, while the common peroneal nerve went through the body of the bifid piriformis muscle, immediately next to its tendon. The two branches continued their course in the thigh without joining and forming a proper sciatic nerve. The medical records of the body donor did not reveal any neurological impairment which could be linked to this anatomical peculiarity. Conclusion: The anatomy of the sciatic nerve could be considered to be a factor of clinical significance. The high prevalence of similar anatomical variations should be kept in mind during the diagnostic process of clinical entities involving the sciatic nerve.

  9. Spinal cord stimulation therapy for localized central pain

    International Nuclear Information System (INIS)

    Hirato, Masafumi; Takahashi, Akio; Watanabe, Katsushige; Kazama, Ken; Yoshimoto, Yuhei

    2008-01-01

    We studied the pathophysiology of localized central pain and the surgical result of spinal cord stimulation. There were 10 cases; 7 males and 3 females from 24 to 77 years old. Pain was caused by peripheral nerve injury in one case, spinal cord injury in two cases and cerebrovascular disease (CVD) (thalamic pain) in 7 cases. All cases were treated by epidural spinal cord stimulation and followed from 0.8 to 8.8 years. Sufficient pain relief was achieved in one case of peripheral nerve and spinal cord injury and in 4 cases of CVD. Moderate pain control was achieved in 2 cases of CVD. In one each case of spinal cord injury and of CVD, pain control was ineffective. In cases with thalamic pain, we studied the correlation between the surgical result of spinal cord stimulation and the clinical features, MRI, fluoro-deoxyglucose (FDG)-positron emission tomography (PET), and somatosensory evoked potentials (SEP) findings before operation. MRI revealed a small to moderate sized lesion on the thalamus or putamen in each case. PET also showed decreased accumulation of FDG on the affected thalamus. In all cases without one fair responder to spinal cord stimulation, we could recognize definite SEP originating in the sensory cortex ipsilateral side to the CVD lesion during contralateral median or posterior tibial nerve stimulation. In the good responders, we could recognize SEP originating in the sensory cortex of the lesion side with less delayed latency or decreased amplitude than in the moderate responders. In this group, test stimulation with low voltage on the spinal cord evoked a sensory effect (paresthesia) over the painful part of the body. Spinal cord stimulation proved to be an effective treatment for localized central pain. In cases with localized central pain after CVD, we could expect to ameliorate the intractable pain in those cases in which SEP or spinal cord test stimulation revealed that the thalamo-cortical system was preserved. (author)

  10. 76 FR 36622 - Proposed Collection; Comment Request for Form 5305A-SEP

    Science.gov (United States)

    2011-06-22

    ... 5305A-SEP AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice and request for comments... Form 5305A-SEP, Salary Reduction Simplified Employee Pension-Individual Retirement Accounts... Agreement. OMB Number: 1545-1012. Form Number: 5305A-SEP. Abstract: Form 5305A-SEP is used by an employer to...

  11. Tibial Stress Injuries: Decisive Diagnosis and Treatment of "Shin Splints."

    Science.gov (United States)

    Couture, Christopher J.; Karlson, Kristine A.

    2002-01-01

    Tibial stress injuries, commonly called shin splints, often result when bone remodeling processes adopt inadequately to repetitive stress. Physicians who are caring for athletic patients must have a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are…

  12. Medial tibial stress syndrome: a critical review

    NARCIS (Netherlands)

    Moen, Maarten H.; Tol, Johannes L.; Weir, Adam; Steunebrink, Miriam; de Winter, Theodorus C.

    2009-01-01

    Medial tibial stress syndrome (MTSS) is one of the most common leg injuries in athletes and soldiers. The incidence of MTSS is reported as being between 4% and 35% in military personnel and athletes. The name given to this condition refers to pain on the posteromedial tibial border during exercise,

  13. A phase 3, placebo controlled study of the safety and efficacy of avanafil for the treatment of erectile dysfunction after nerve sparing radical prostatectomy.

    Science.gov (United States)

    Mulhall, John P; Burnett, Arthur L; Wang, Run; McVary, Kevin T; Moul, Judd W; Bowden, Charles H; DiDonato, Karen; Shih, Winnie; Day, Wesley W

    2013-06-01

    We evaluated the safety and efficacy of 100 and 200 mg avanafil for the treatment of adult males with erectile dysfunction after bilateral nerve sparing radical prostatectomy. This was a double-blind, placebo controlled, parallel group, phase 3 study in males age 18 to 70 years with a history of erectile dysfunction of 6 months or more after bilateral nerve sparing radical prostatectomy. Patients were randomized to 100 or 200 mg avanafil or placebo (taken 30 minutes before sexual activity) for 12 weeks. Primary end points included successful vaginal insertion (Sexual Encounter Profile [SEP] question 2), successful intercourse (SEP3) and change in score on the erectile function domain of the International Index of Erectile Function (IIEF-EF) questionnaire. A total of 298 patients were randomized and 84.6% completed the study. At baseline 16.1% were age 65 years or older and 71.5% had severe erectile dysfunction (mean overall IIEF-EF domain score 9.2). After 12 weeks there were significantly greater increases in SEP2 and SEP3 and change in mean IIEF-EF domain score with 100 and 200 mg avanafil vs placebo (p erectile function after prostatectomy. Results suggest a rapid onset of action and sustained duration of effect, with all 3 primary end points being achieved at both dose levels. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Distribution of elements and water in peripheral nerve of streptozocin-induced diabetic rats

    International Nuclear Information System (INIS)

    Lowery, J.M.; Eichberg, J.; Saubermann, A.J.; LoPachin, R.M. Jr.

    1990-01-01

    Accumulating evidence suggests that alterations in Na, Ca, K, and other biologically relevant elements play a role in the mechanism of cell injury. The pathogenesis of experimental diabetic neuropathy is unknown but might include changes in the distribution of these elements in morphological compartments. In this study, this possibility was examined via electron-probe X-ray microanalysis to measure both concentrations of elements (millimoles of element per kilogram dry or wet weight) and cell water content (percent water) in frozen, unfixed, unstained sections of peripheral nerve from control and streptozocin-induced diabetic rats. Our results indicate that after 20 wk of experimental diabetes, mitochondria and axoplasm from myelinated axons of proximal sciatic nerve displayed diminished K and Cl content, whereas in tibial nerve, the intraaxonal levels of these elements increased. In distal sciatic nerve, mitochondrial and axoplasmic levels of Ca were increased, whereas other elemental alterations were not observed. These regional changes resulted in a reversal of the decreasing proximodistal concentration gradients for K and Cl, which exist in nondiabetic rat sciatic nerve. Our results cannot be explained on the basis of altered water. Highly distinctive changes in elemental distribution observed might be a critical component of the neurotoxic mechanism underlying diabetic neuropathy

  15. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study.

    Science.gov (United States)

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-Ichi

    2017-06-18

    To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fracture and the geometry of the tibial plateau were reviewed and measured on MRI. Thirteen of 14 stress fractures were linear, and one of them stellated on MRI images. The location of fractures was classified into three types. Three fractures were located anteromedially (AM type), six posteromedially (PM type), and five posteriorly (P type) at the medial tibial plateau. In addition, tibial posterior slope at the medial tibial plateau tended to be larger when the fracture was located more posteriorly on MRI. We found that MRI showed three different localizations of medial tibial plateau stress fractures, which were associated with tibial posterior slope at the medial tibial plateau.

  16. Evaluation and use of regenerative multi electrode interfaces in peripheral nerves

    Science.gov (United States)

    Desai, Vidhi

    Peripheral nerves offer unique accessibility to the innate motor and sensory pathways that can be interfaced with high degree of selectivity for intuitive and bidirectional control of advanced upper extremity prosthetic limbs. Several peripheral nerve interfaces have been proposed and investigated over the last few decades with significant progress made in the area of sensory feedback. However, clinical translation still remains a formidable challenge due to the lack of long term recordings. Prominent causes include signal degradation, eventual interface failures, and lack of specificity in the low amplitude nerve signals. This dissertation evaluates the capabilities of the newly developed Regenerative Multi-electrode Interface (REMI) by the characterization of signal quality progression, the identification of interfaced axon types, and the demonstration of "functional linkage" between acquired signals and target organs. Chapter 2 details the chronic recording of high quality signals from REMI in sciatic nerve which remained stable over a 120 day implantation period indicative of minimal ongoing tissue response with no detrimental effects on the recording ability. The dominant cause of failures was attributable to abiotic factors pertaining to the connector/wire breakage, observed in 76% of REMI implants. Also, the REMI implants had 20% higher success rate and significantly larger Signal to Noise Ratio (SNR) in comparison to the Utah Slanted Electrode Array (USEA). Chapter 3 describes the successful feasibility of interfacing with motor and sensory axons by REMI implantation in the tibial and sural fascicles of the sciatic nerve. A characteristic sampling bias towards recording signals from medium-to-large diameter axons that are primarily involved in mechanoception and proprioception sensory functions was uncovered. Specific bursting units (Inter Spike Interval of 30-70ms) were observed most frequently from the tibial fascicle during bipedal locomotion. Chapter 4

  17. Randomized clinical trial of percutaneous tibial nerve stimulation versus sham electrical stimulation in patients with faecal incontinence.

    Science.gov (United States)

    van der Wilt, A A; Giuliani, G; Kubis, C; van Wunnik, B P W; Ferreira, I; Breukink, S O; Lehur, P A; La Torre, F; Baeten, C G M I

    2017-08-01

    The aim was to assess the effects of percutaneous tibial nerve stimulation (PTNS) in the treatment of faecal incontinence (FI) by means of an RCT. Patients aged over 18 years with FI were included in a multicentre, single-blinded RCT. The primary endpoint was reduction in the median or mean number of FI episodes per week. Secondary endpoints were changes in measures of FI severity, and disease-specific and generic quality of life. Outcomes were compared between PTNS and sham stimulation after 9 weeks of treatment. A higher proportion of patients in the PTNS (13 of 29) than in the sham (6 of 30) group showed a reduction of at least 50 per cent in the median number of FI episodes/week (incidence rate ratio (IRR) 2·40, 95 per cent c.i. 1·10 to 5·24; P = 0·028), but not in the mean number of episodes/week (10 of 29 versus 8 of 30; IRR 1·42, 0·69 to 2·92; P = 0·347). The absolute median number of FI episodes per week decreased in the PTNS but not in the sham group (IRR 0·66, 0·44 to 0·98; P = 0·041), as did the mean number (IRR 0·65 (0·45 to 0·97); P = 0·034). Scores on the Cleveland Clinic Florida faecal incontinence scale decreased significantly in both groups, but more steeply in the PTNS group (mean difference -1·3, 95 per cent c.i. -2·6 to 0·0; P = 0·049). The aggregated mental component score of Short Form 36 improved in the PTNS but not in the sham group (mean difference 5·1, 0·5 to 9·6; P = 0·028). PTNS may offer a small advantage in the clinical management of FI that is insufficiently responsive to conservative treatment. The key challenge will be to identify patients who may benefit most from this minimally invasive surgical procedure. Registration number: NCT00974909 (http://www.clinicaltrials.gov). © 2017 BJS Society Ltd Published by John Wiley & Sons Ltd.

  18. [Surgical approaches to tibial plateau fractures].

    Science.gov (United States)

    Krause, Matthias; Müller, Gunnar; Frosch, Karl-Heinz

    2018-06-06

    Intra-articular tibial plateau fractures can present a surgical challenge due to complex injury patterns and compromised soft tissue. The treatment goal is to spare the soft tissue and an anatomical reconstruction of the tibial articular surface. Depending on the course of the fracture, a fracture-specific access strategy is recommended to provide correct positioning of the plate osteosynthesis. While the anterolateral approach is used in the majority of lateral tibial plateau fractures, only one third of the joint surface is visible; however, posterolateral fragments require an individual approach, e. g. posterolateral or posteromedial. If necessary, osteotomy of the femoral epicondyles can improve joint access for reduction control. Injuries to the posterior columns should be anatomically reconstructed and biomechanically correctly addressed via posterior approaches. Bony posterior cruciate ligament tears can be refixed via a minimally invasive posteromedial approach.

  19. Understanding the etiology of the posteromedial tibial stress fracture.

    Science.gov (United States)

    Milgrom, Charles; Burr, David B; Finestone, Aharon S; Voloshin, Arkady

    2015-09-01

    Previous human in vivo tibial strain measurements from surface strain gauges during vigorous activities were found to be below the threshold value of repetitive cyclical loading at 2500 microstrain in tension necessary to reduce the fatigue life of bone, based on ex vivo studies. Therefore it has been hypothesized that an intermediate bone remodeling response might play a role in the development of tibial stress fractures. In young adults tibial stress fractures are usually oblique, suggesting that they are the result of failure under shear strain. Strains were measured using surface mounted unstacked 45° rosette strain gauges on the posterior aspect of the flat medial cortex just below the tibial midshaft, in a 48year old male subject while performing vertical jumps, staircase jumps and running up and down stadium stairs. Shear strains approaching 5000 microstrain were recorded during stair jumping and vertical standing jumps. Shear strains above 1250 microstrain were recorded during runs up and down stadium steps. Based on predictions from ex vivo studies, stair and vertical jumping tibial shear strain in the test subject was high enough to potentially produce tibial stress fracture subsequent to repetitive cyclic loading without necessarily requiring an intermediate remodeling response to microdamage. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Comparison of the 26 May 2012 SEP Event with the 3 November 2011 SEP Event

    Science.gov (United States)

    Makela, P. A.; Gopalswamy, N.; Thakur, N.; Xie, H.

    2015-12-01

    We compare the solar and interplanetary events associated with two large solar energetic particle (SEP) events on 26 May 2012 and 3 November 2011. Both SEP events were detected at three longitudinally widely separated locations by STEREO A and B spacecraft (more than 100 deg away from Earth) and the Wind and SOHO spacecraft near Earth. In Earth view, the November 2011 eruption occurred far behind the east limb at N09E154, whereas the May 2012 eruption occurred closer to the west limb at N15W121, suggesting that SEPs accelerated during the 2012 event might have easier access to Earth. Even though the 2012 event was more intense in the GOES >10 MeV proton channel (peak intensity 14 pfu) than the 2011 event (peak intensity 4 pfu), we find that the latter event was more intense at higher energies (> 40 MeV). Also, the initial rise at lower energies was slightly faster for the 2011 event as measured by SOHO/ERNE. In addition, the CME associated with the May 2012 event was faster with an estimated space speed of ~2029 km/s than that in the November 2011 event (1188 km/s). STEREO/EUVI images of the associated post-eruption arcades (PEAs) indicate that their orientations were different: the PEA of the May 2012 event had a high inclination (north-south), while the inclination of the PEA of the 2011 event was more moderate. Differences in the flux rope orientation may also have effect on the longitudinal extent of the SEP events. These observations suggest that the dependence of solar proton intensities on the observer's longitudinal distance from the solar source is more complex than traditionally assumed.

  1. Spider silk constructs enhance axonal regeneration and remyelination in long nerve defects in sheep.

    Directory of Open Access Journals (Sweden)

    Christine Radtke

    Full Text Available BACKGROUND: Surgical reapposition of peripheral nerve results in some axonal regeneration and functional recovery, but the clinical outcome in long distance nerve defects is disappointing and research continues to utilize further interventional approaches to optimize functional recovery. We describe the use of nerve constructs consisting of decellularized vein grafts filled with spider silk fibers as a guiding material to bridge a 6.0 cm tibial nerve defect in adult sheep. METHODOLOGY/PRINCIPAL FINDINGS: The nerve constructs were compared to autologous nerve grafts. Regeneration was evaluated for clinical, electrophysiological and histological outcome. Electrophysiological recordings were obtained at 6 months and 10 months post surgery in each group. Ten months later, the nerves were removed and prepared for immunostaining, electrophysiological and electron microscopy. Immunostaining for sodium channel (NaV 1.6 was used to define nodes of Ranvier on regenerated axons in combination with anti-S100 and neurofilament. Anti-S100 was used to identify Schwann cells. Axons regenerated through the constructs and were myelinated indicating migration of Schwann cells into the constructs. Nodes of Ranvier between myelin segments were observed and identified by intense sodium channel (NaV 1.6 staining on the regenerated axons. There was no significant difference in electrophysiological results between control autologous experimental and construct implantation indicating that our construct are an effective alternative to autologous nerve transplantation. CONCLUSIONS/SIGNIFICANCE: This study demonstrates that spider silk enhances Schwann cell migration, axonal regrowth and remyelination including electrophysiological recovery in a long-distance peripheral nerve gap model resulting in functional recovery. This improvement in nerve regeneration could have significant clinical implications for reconstructive nerve surgery.

  2. Implementation of an office-based semen preparation method (SEP ...

    African Journals Online (AJOL)

    Implementation of an office-based semen preparation method (SEP-D Kit) for intra-uterine insemination (IUI): A controlled randomised study to compare the IUI pregnancy outcome between a routine (swim-up) and the SEP-D Kit method.

  3. Current understanding of SEP acceleration and propagation

    International Nuclear Information System (INIS)

    Klecker, B

    2013-01-01

    The solar energetic particle (SEP) populations of electrons and ions are highly variable in space and time, in intensity, energy, and composition. Over the last ∼20 years advanced instrumentation onboard many spacecraft (e.g. ACE, Coronas, GOES, Hinode, RHESSI, SAMPEX, SDO, SOHO, STEREO, TRACE, Ulysses, Yokoh, to name a few) extended our ability to explore the characteristics of solar energetic particles by in-situ measurements in interplanetary space and by observing their source characteristics near the Sun by remote-sensing observation of electromagnetic emission over a wide frequency range. These measurements provide crucial information for understanding the sources of the particle populations and the acceleration and propagation processes involved. We are now able to measure intensity-time profiles and anisotropies, energy spectra, elemental and isotopic abundances, and the ionic charge of particles over an extended energy range of 0.01 to several 100 MeV/nuc and for a large dynamic range of particle intensities. Furthermore, multi-spacecraft in-situ observations at different solar longitudes and latitudes provide new insight into the acceleration and propagation processes of SEPs near the Sun and in interplanetary space. In this paper we present an overview of SEP observations, their implications for SEP acceleration and propagation processes, and discuss open questions.

  4. Action of vanillin (Vanilla planifolia) on the morphology of tibialis anterior and soleus muscles after nerve injury.

    Science.gov (United States)

    Peretti, Ana Luiza; Antunes, Juliana Sobral; Lovison, Keli; Kunz, Regina Inês; Castor, Lidyane Regina Gomes; Brancalhão, Rose Meire Costa; Bertolini, Gladson Ricardo Flor; Ribeiro, Lucinéia de Fátima Chasko

    2017-01-01

    To evaluate the action of vanillin (Vanilla planifolia) on the morphology of tibialis anterior and soleus muscles after peripheral nerve injury. Wistar rats were divided into four groups, with seven animals each: Control Group, Vanillin Group, Injury Group, and Injury + Vanillin Group. The Injury Group and the Injury + Vanillin Group animals were submitted to nerve injury by compression of the sciatic nerve; the Vanillin Group and Injury + Vanillin Group, were treated daily with oral doses of vanillin (150mg/kg) from the 3rd to the 21st day after induction of nerve injury. At the end of the experiment, the tibialis anterior and soleus muscles were dissected and processed for light microscopy and submitted to morphological analysis. The nerve compression promoted morphological changes, typical of denervation, and the treatment with vanillin was responsible for different responses in the studied muscles. For the tibialis anterior, there was an increase in the number of satellite cells, central nuclei and fiber atrophy, as well as fascicular disorganization. In the soleus, only increased vascularization was observed, with no exacerbation of the morphological alterations in the fibers. The treatment with vanillin promoted increase in intramuscular vascularization for the muscles studied, with pro-inflammatory potential for tibialis anterior, but not for soleus muscle. Avaliar a ação da vanilina (Vanilla planifolia) sobre a morfologia dos músculos tibial anterior e sóleo após lesão nervosa periférica. Ratos Wistar foram divididos em quatro grupos, com sete animais cada, sendo Grupo Controle, Grupo Vanilina, Grupo Lesão e Grupo Lesão + Vanilina. Os animais dos Grupos Lesão e Grupo Lesão + Vanilina foram submetidos à lesão nervosa por meio da compressão do nervo isquiático, e os Grupos Vanilina e Grupo Lesão + Vanilina foram tratados diariamente com doses orais de vanilina (150mg/kg) do 3o ao 21o dia após a indução da lesão nervosa. Ao término do

  5. SEP-class genes in Prunus mume and their likely role in floral organ development.

    Science.gov (United States)

    Zhou, Yuzhen; Xu, Zongda; Yong, Xue; Ahmad, Sagheer; Yang, Weiru; Cheng, Tangren; Wang, Jia; Zhang, Qixiang

    2017-01-13

    Flower phylogenetics and genetically controlled development have been revolutionised during the last two decades. However, some of these evolutionary aspects are still debatable. MADS-box genes are known to play essential role in specifying the floral organogenesis and differentiation in numerous model plants like Petunia hybrida, Arabidopsis thaliana and Antirrhinum majus. SEPALLATA (SEP) genes, belonging to the MADS-box gene family, are members of the ABCDE and quartet models of floral organ development and play a vital role in flower development. However, few studies of the genes in Prunus mume have yet been conducted. In this study, we cloned four PmSEPs and investigated their phylogenetic relationship with other species. Expression pattern analyses and yeast two-hybrid assays of these four genes indicated their involvement in the floral organogenesis with PmSEP4 specifically related to specification of the prolificated flowers in P. mume. It was observed that the flower meristem was specified by PmSEP1 and PmSEP4, the sepal by PmSEP1 and PmSEP4, petals by PmSEP2 and PmSEP3, stamens by PmSEP2 and PmSEP3 and pistils by PmSEP2 and PmSEP3. With the above in mind, flower development in P. mume might be due to an expression of SEP genes. Our findings can provide a foundation for further investigations of the transcriptional factors governing flower development, their molecular mechanisms and genetic basis.

  6. Intercalary bone segment transport in treatment of segmental tibial defects

    International Nuclear Information System (INIS)

    Iqbal, A.; Amin, M.S.

    2002-01-01

    Objective: To evaluate the results and complications of intercalary bone segment transport in the treatment of segmental tibial defects. Design: This is a retrospective analysis of patients with segmental tibial defects who were treated with intercalary bone segment transport method. Place and Duration of Study: The study was carried out at Combined Military Hospital, Rawalpindi from September 1997 to April 2001. Subjects and methods: Thirteen patients were included in the study who had developed tibial defects either due to open fractures with bone loss or subsequent to bone debridement of infected non unions. The mean bone defect was 6.4 cms and there were eight associated soft tissue defects. Locally made unilateral 'Naseer-Awais' (NA) fixator was used for bone segment transport. The distraction was done at the rate of 1mm/day after 7-10 days of osteotomy. The patients were followed-up fortnightly during distraction and monthly thereafter. The mean follow-up duration was 18 months. Results: The mean time in external fixation was 9.4 months. The m ean healing index' was 1.47 months/cm. Satisfactory union was achieved in all cases. Six cases (46.2%) required bone grafting at target site and in one of them grafting was required at the level of regeneration as well. All the wounds healed well with no residual infection. There was no residual leg length discrepancy of more than 20 mm nd one angular deformity of more than 5 degrees. The commonest complication encountered was pin track infection seen in 38% of Shanz Screws applied. Loosening occurred in 6.8% of Shanz screws, requiring re-adjustment. Ankle joint contracture with equinus deformity and peroneal nerve paresis occurred in one case each. The functional results were graded as 'good' in seven, 'fair' in four, and 'poor' in two patients. Overall, thirteen patients had 31 (minor/major) complications with a ratio of 2.38 complications per patient. To treat the bone defects and associated complications, a mean of

  7. Bone stress in runners with tibial stress fracture.

    Science.gov (United States)

    Meardon, Stacey A; Willson, John D; Gries, Samantha R; Kernozek, Thomas W; Derrick, Timothy R

    2015-11-01

    Combinations of smaller bone geometry and greater applied loads may contribute to tibial stress fracture. We examined tibial bone stress, accounting for geometry and applied loads, in runners with stress fracture. 23 runners with a history of tibial stress fracture & 23 matched controls ran over a force platform while 3-D kinematic and kinetic data were collected. An elliptical model of the distal 1/3 tibia cross section was used to estimate stress at 4 locations (anterior, posterior, medial and lateral). Inner and outer radii for the model were obtained from 2 planar x-ray images. Bone stress differences were assessed using two-factor ANOVA (α=0.05). Key contributors to observed stress differences between groups were examined using stepwise regression. Runners with tibial stress fracture experienced greater anterior tension and posterior compression at the distal tibia. Location, but not group, differences in shear stress were observed. Stepwise regression revealed that anterior-posterior outer diameter of the tibia and the sagittal plane bending moment explained >80% of the variance in anterior and posterior bone stress. Runners with tibial stress fracture displayed greater stress anteriorly and posteriorly at the distal tibia. Elevated tibial stress was associated with smaller bone geometry and greater bending moments about the medial-lateral axis of the tibia. Future research needs to identify key running mechanics associated with the sagittal plane bending moment at the distal tibia as well as to identify ways to improve bone geometry in runners in order to better guide preventative and rehabilitative efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Conjunct SEP and MEP monitoring in resection of infratentorial lesions: lessons learned in a cohort of 210 patients.

    Science.gov (United States)

    Kodama, Kunihiko; Javadi, Mani; Seifert, Volker; Szelényi, Andrea

    2014-12-01

    During the surgical removal of infratentorial lesions, intraoperative neuromonitoring is mostly focused on cranial nerve assessment and brainstem auditory potentials. Despite the known risk of perforating vessel injury during microdissection within the vicinity of the brainstem, there are few reports about intraoperative neuromonitoring with somatosensory evoked potentials (SEPs) and motor evoked potentials (MEPs) assessing the medial lemniscus and corticospinal tract. This study analyses the occurrence of intraoperative changes in MEPs and SEPs with regard to lesion location and postoperative neurological outcome. The authors analyzed 210 cases in which patients (mean age 49 ± 13 years, 109 female) underwent surgeries involving the skull base (n = 104), cerebellum (n = 63), fourth ventricle (n = 28), brainstem (n = 12), and foramen magnum (n = 3). Of 210 surgeries, 171 (81.4%) were uneventful with respect to long-tract monitoring. Nine (23%) of the 39 SEP and/or MEP alterations were transient and were only followed by a slight permanent deficit in 1 case. Permanent deterioration only was seen in 19 (49%) of 39 cases; the deterioration was related to tumor dissection in 4 of these cases, and permanent deficit (moderate-severe) was seen in only 1 of these 4 cases. Eleven patients (28%) had losses of at least 1 modality, and in 9 of these 11 cases, the loss was related to surgical microdissection within the vicinity of the brainstem. Four of these 9 patients suffered a moderate-to-severe long-term deficit. For permanent changes, the positive predictive value for neuromonitoring of the long tracts was 0.467, the negative predictive value was 0.989, the sensitivity was 0.875, and the specificity 0.918. Twenty-eight (72%) of 39 SEP and MEP alterations occurred in 66 cases involving intrinsic brainstem tumors or tumors adjacent to the brainstem. Lesion location and alterations in intraoperative neuromonitoring significantly correlated with patients' outcome (p < 0

  9. Systematic radiographic evaluation of tibial hemimelia with orthopedic implications

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan-List, Katia [Rochester General Hospital, Department of Diagnostic Imaging, Rochester, NY (United States); Klionsky, Nina B. [University of Rochester Medical Center, School of Medicine and Dentistry, Rochester, NY (United States); Golisano Children' s Hospital, Department of Radiology, Rochester, NY (United States); Sanders, James O. [University of Rochester Medical Center, School of Medicine and Dentistry, Rochester, NY (United States); Golisano Children' s Hospital, Department of Orthopaedics, Rochester, NY (United States); Golisano Children' s Hospital, Department of Pediatrics, Rochester, NY (United States); Katz, Michael E. [St. Mary' s Medical Center and Palm Beach Children' s Hospital, Department of Radiology, West Palm Beach, FL (United States)

    2017-04-15

    Tibial hemimelia is a rare lower-extremity pre-axial longitudinal deficiency characterized by complete or partial absence of the tibia. The reported incidence is 1 in 1 million live births. In this pictorial essay, we define tibial hemimelia and describe associated conditions and principles of preoperative imaging assessment for a child with tibial hemimelia. We also indicate the imaging findings that might influence the choice of treatment, describe the most widely used classification systems, and briefly discuss current treatment approaches. (orig.)

  10. Systematic radiographic evaluation of tibial hemimelia with orthopedic implications

    International Nuclear Information System (INIS)

    Kaplan-List, Katia; Klionsky, Nina B.; Sanders, James O.; Katz, Michael E.

    2017-01-01

    Tibial hemimelia is a rare lower-extremity pre-axial longitudinal deficiency characterized by complete or partial absence of the tibia. The reported incidence is 1 in 1 million live births. In this pictorial essay, we define tibial hemimelia and describe associated conditions and principles of preoperative imaging assessment for a child with tibial hemimelia. We also indicate the imaging findings that might influence the choice of treatment, describe the most widely used classification systems, and briefly discuss current treatment approaches. (orig.)

  11. Gender differences in passive knee biomechanical properties in tibial rotation.

    Science.gov (United States)

    Park, Hyung-Soon; Wilson, Nicole A; Zhang, Li-Qun

    2008-07-01

    The anterior cruciate ligament (ACL) is the most commonly injured knee ligament with the highest incidence of injury in female athletes who participate in pivoting sports. Noncontact ACL injuries commonly occur with both internal and external tibial rotation. ACL impingement against the lateral wall of the intercondylar notch during tibial external rotation and abduction has been proposed as an injury mechanism, but few studies have evaluated in vivo gender-specific differences in laxity and stiffness in external and internal tibial rotations. The purpose of this study was to evaluate these differences. The knees of 10 male and 10 female healthy subjects were rotated between internal and external tibial rotation with the knee at 60 degrees of flexion. Joint laxity, stiffness, and energy loss were compared between male and female subjects. Women had higher laxity (p = 0.01), lower stiffness (p = 0.038), and higher energy loss (p = 0.008) in external tibial rotation than did men. The results suggest that women may be at greater risk of ACL injury resulting from impingement against the lateral wall of the intercondylar notch, which has been shown to be associated with external tibial rotation and abduction.

  12. Improvement of the SEP protocol based on community structure of node degree

    Science.gov (United States)

    Li, Donglin; Wei, Suyuan

    2017-05-01

    Analyzing the Stable election protocol (SEP) in wireless sensor networks and aiming at the problem of inhomogeneous cluster-heads distribution and unreasonable cluster-heads selectivity and single hop transmission in the SEP, a SEP Protocol based on community structure of node degree (SEP-CSND) is proposed. In this algorithm, network node deployed by using grid deployment model, and the connection between nodes established by setting up the communication threshold. The community structure constructed by node degree, then cluster head is elected in the community structure. On the basis of SEP, the node's residual energy and node degree is added in cluster-heads election. The information is transmitted with mode of multiple hops between network nodes. The simulation experiments showed that compared to the classical LEACH and SEP, this algorithm balances the energy consumption of the entire network and significantly prolongs network lifetime.

  13. Anatomical basis for sciatic nerve block at the knee level

    Directory of Open Access Journals (Sweden)

    Fabiano Timbó Barbosa

    2015-05-01

    Full Text Available Background and objectives: Recently, administration of sciatic nerve block has been revised due to the potential benefit for postoperative analgesia and patient satisfaction after the advent of ultrasound. The aim of this study was to describe the anatomical relations of the sciatic nerve in the popliteal fossa to determine the optimal distance the needle must be positioned in order to realize the sciatic nerve block anterior to its bifurcation into the tibial and common fibular nerve. Method: The study was conducted by dissection of human cadavers’ popliteal fossa, fixed in 10% formalin, from the Laboratory of Human Anatomy and Morphology Departments of the Universidade Federal de Alagoas and Universidade de Ciências da Saúde de Alagoas. Access to the sciatic nerve was obtained. Results: 44 popliteal fossa were analyzed. The bifurcation of the sciatic nerve in relation to the apex of the fossa was observed. There was bifurcation in: 67.96% below the apex, 15.90% above the apex, 11.36% near the apex, and 4.78% in the gluteal region. Conclusions: The sciatic nerve bifurcation to its branches occurs at various levels, and the chance to succeed when the needle is placed between 5 and 7 cm above the popliteal is 95.22%. Resumo: Justificativa e objetivos: Recentemente a feitura de bloqueio do nervo isquiático tem sido revista devido ao potencial benéfico para analgesia pós-operatória e satisfação dos pacientes após o advento da ultrassonografia. O objetivo deste estudo foi descrever as relações anatômicas do nervo isquiático na fossa poplítea para determinar a distância ideal em que a agulha deve ser posicionada para a feitura do bloqueio anestésico do nervo isquiático anterior a sua bifurcação em nervo tibial e fibular comum. Método: O trabalho foi feito por meio de dissecção de fossa poplítea de cadáveres humanos, fixados em formol a 10%, provenientes do Laboratório de Anatomia Humana dos departamentos de Morfologia da

  14. EAMJ Nephrotoxicity Sep 09.indd

    African Journals Online (AJOL)

    2009-09-01

    Sep 1, 2009 ... Secondary objective was to determine all-cause mortality in the same group. Design: Prospective ... and hypomagnesaemia were high in this studied population. ... used tests include serum urea and serum creatinine.

  15. Brief electrical stimulation improves nerve regeneration after delayed repair in Sprague Dawley rats.

    Science.gov (United States)

    Elzinga, Kate; Tyreman, Neil; Ladak, Adil; Savaryn, Bohdan; Olson, Jaret; Gordon, Tessa

    2015-07-01

    Functional recovery after peripheral nerve injury and surgical repair declines with time and distance because the injured neurons without target contacts (chronic axotomy) progressively lose their regenerative capacity and chronically denervated Schwann cells (SCs) atrophy and fail to support axon regeneration. Findings that brief low frequency electrical stimulation (ES) accelerates axon outgrowth and muscle reinnervation after immediate nerve surgery in rats and human patients suggest that ES might improve regeneration after delayed nerve repair. To test this hypothesis, common peroneal (CP) neurons were chronically axotomized and/or tibial (TIB) SCs and ankle extensor muscles were chronically denervated by transection and ligation in rats. The CP and TIB nerves were cross-sutured after three months and subjected to either sham or one hour 20Hz ES. Using retrograde tracing, we found that ES significantly increased the numbers of both motor and sensory neurons that regenerated their axons after a three month period of chronic CP axotomy and/or chronic TIB SC denervation. Muscle and motor unit forces recorded to determine the numbers of neurons that reinnervated gastrocnemius muscle demonstrated that ES significantly increased the numbers of motoneurons that reinnervated chronically denervated muscles. We conclude that electrical stimulation of chronically axotomized motor and sensory neurons is effective in accelerating axon outgrowth into chronically denervated nerve stumps and improving target reinnervation after delayed nerve repair. Possible mechanisms for the efficacy of ES in promoting axon regeneration and target reinnervation after delayed nerve repair include the upregulation of neurotrophic factors. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. EAMJ Aetiology Sep 09.indd

    African Journals Online (AJOL)

    2009-09-09

    Sep 9, 2009 ... Laboratory testing: Bacteria were isolated by culture after inoculating stool .... for isolation of multiple pathogens from one stool specimen. ... Asymptomatic Adjusted Odds. P-value. Adjusted. (n=436). (n=562). Ratio* (95%.

  17. EAMJ Aetiology Sep 09.indd

    African Journals Online (AJOL)

    2009-09-09

    Sep 9, 2009 ... Most bacteria were resistant to commonly used antimicrobials irrespective of HIV status. ... Empiric treatment should be tailored ... followed-up. Enrollment consisted of two phases, ..... in Senegalese adults in relation to human.

  18. [Custom-designed 3D tibial augmentation for knee replacement].

    Science.gov (United States)

    Jirman, R; Vavrík, P; Horák, Z

    2009-02-01

    Reconstruction with the use of custom-made implants aims at optimal replacement of lost or damaged bone structures and restoration of their funkction. In this study the development and construction of a custom-made implant and the operative technique used for the treatment of an extensive tibial defect are described. The patient was a 65-year-old man treated for over 20 years for psoriatic arthritis and severe instability of the right knee, particularly in the frontal plane, with a worsening varus deformity. The radiogram showed an extensive destruction of the medial tibial condyle that also deeply involved the lateral condyle. The extent of defect made it impossible to use any commercial tibial augmentation. The geometry of the custom-designed implant for the medial tibial condyle was constructed on the basis of a 3D defect model and the shape of the medial tibial condyle of the collateral knee seen on CT scans. After its correct shape was verified on a plastic model, its coordinates were set in the software of a machine tool, and a titanium augmentation otherwise compatible with a standard knee replacement was produced.The use of such a custom implant to complete standard total knee arthroplasty has so far been demanding in terms of organisation and manufacture. Its production in the future could be facilitated by substituting titanium for plastic material such as poly-ether-ether-ketone (PEEK). Key words: custom-made implant, tibial augmentation, knee prosthesis.

  19. Cartilaginous avulsion fracture of the tibial spine in a 5-year-old girl

    International Nuclear Information System (INIS)

    Kim, Jung Ryul; Song, Ji Hun; Lee, Ju Hong; Lee, Sang Yong; Yoo, Wan Hee

    2008-01-01

    Fractures of the tibial spine usually occur in children aged 8 to 14 years. Usually, radiographs will demonstrate a tibial spine fracture, with the degree of displacement. Tibial spine fractures in younger children have not been reported in the previously published literature. We report a tibial spine fracture that occurred in 5-year-old girl. The cartilaginous avulsion fracture of the tibial spine was not revealed by radiographs because it was limited to the cartilaginous portion of the proximal tibia. (orig.)

  20. The soleal line: a cause of tibial pseudoperiostitis.

    Science.gov (United States)

    Levine, A H; Pais, M J; Berinson, H; Amenta, P S

    1976-04-01

    An unusually prominent soleal line (a normal anatomic variant) may mimic periosteal reaction along the posterior margin of the proximal tibial shaft. This area of pseudoperiostitis is differentiated from hyperostoses arising from the anterior tibial tubercle and the interosseous membrane. It is always associated with normal, undisturbed architecture of the underlying bone.

  1. Intrinsic factors associated with medial tibial stress syndrome in ...

    African Journals Online (AJOL)

    Intrinsic factors associated with medial tibial stress syndrome in athletes: A large case-control study. ... Medial tibial stress syndrome (MTSS) is the most common lower-leg injury in athletes, and is thought to be caused by ... from 32 Countries:.

  2. Observations of IMF coherent structures and their relationship to SEP dropout events

    Directory of Open Access Journals (Sweden)

    L. Trenchi

    2013-08-01

    Full Text Available The solar energetic particle (SEP events from impulsive solar flares are often characterized by short-timescale modulations affecting, at the same time, particles with different energies. Several models and simulations suggest that these modulations are observed when SEPs propagate through magnetic structures with a different connection with the flare site. However, in situ observations rarely showed clear magnetic signatures associated with these modulations. In this paper we used the Grad–Shafranov reconstruction to perform a detailed analysis of the local magnetic field topology during the SEP event of 9–10 January 1999, characterized by several SEP dropouts. An optimization procedure is used to identify, during this SEP event, the magnetic structures which better satisfy the Grad–Shafranov assumptions and to evaluate the direction of their invariant axis. We found that these two-dimensional structures, which are flux ropes or current sheets with a more complex field topology, are generally associated with the maxima in the SEP counts. This association suggests that the SEPs propagate within these structures and, since their gyration radii is much smaller than the transverse dimension of these structure, cannot escape from them.

  3. End-to-side neurorraphy: a long-term study of neural regeneration in a rat model.

    Science.gov (United States)

    Tarasidis, G; Watanabe, O; Mackinnon, S E; Strasberg, S R; Haughey, B H; Hunter, D A

    1998-10-01

    This study evaluated long-term reinnervation of an end-to-side neurorraphy and the resultant functional recovery in a rat model. The divided distal posterior tibial nerve was repaired to the side of an intact peroneal nerve. Control groups included a cut-and-repair of the posterior tibial nerve and an end-to-end repair of the peroneal nerve to the posterior tibial nerve. Evaluations included walking-track analysis, nerve conduction studies, muscle mass measurements, retrograde nerve tracing, and histologic evaluation. Walking tracks indicated poor recovery of posterior tibial nerve function in the experimental group. No significant difference in nerve conduction velocities was seen between the experimental and control groups. Gastrocnemius muscle mass measurements revealed no functional recovery in the experimental group. Similarly, retrograde nerve tracing revealed minimal motor neuron staining in the experimental group. However, some sensory staining was seen within the dorsal root ganglia of the end-to-side group. Histologic study revealed minimal myelinated axonal regeneration in the experimental group as compared with findings in the other groups. These results suggest that predominantly sensory regeneration occurs in an end-to-side neurorraphy at an end point of 6 months.

  4. Dynamic impact of brief electrical nerve stimulation on the neural immune axis-polarization of macrophages toward a pro-repair phenotype in demyelinated peripheral nerve.

    Science.gov (United States)

    McLean, Nikki A; Verge, Valerie M K

    2016-09-01

    Demyelinating peripheral nerves are infiltrated by cells of the monocyte lineage, including macrophages, which are highly plastic, existing on a continuum from pro-inflammatory M1 to pro-repair M2 phenotypic states. Whether one can therapeutically manipulate demyelinated peripheral nerves to promote a pro-repair M2 phenotype remains to be elucidated. We previously identified brief electrical nerve stimulation (ES) as therapeutically beneficial for remyelination, benefits which include accelerated clearance of macrophages, making us theorize that ES alters the local immune response. Thus, the impact of ES on the immune microenvironment in the zone of demyelination was examined. Adult male rat tibial nerves were focally demyelinated via 1% lysophosphatidyl choline (LPC) injection. Five days later, half underwent 1 hour 20 Hz sciatic nerve ES proximal to the LPC injection site. ES had a remarkable and significant impact, shifting the macrophage phenotype from predominantly pro-inflammatory/M1 toward a predominantly pro-repair/M2 one, as evidenced by an increased incidence of expression of M2-associated phenotypic markers in identified macrophages and a decrease in M1-associated marker expression. This was discernible at 3 days post-ES (8 days post-LPC) and continued at the 5 day post-ES (10 days post-LPC) time point examined. ES also affected chemokine (C-C motif) ligand 2 (CCL2; aka MCP-1) expression in a manner that correlated with increases and decreases in macrophage numbers observed in the demyelination zone. The data establish that briefly increasing neuronal activity favorably alters the immune microenvironment in demyelinated nerve, rapidly polarizing macrophages toward a pro-repair phenotype, a beneficial therapeutic concept that may extend to other pathologies. GLIA 2016;64:1546-1561. © 2016 Wiley Periodicals, Inc.

  5. EAMJ Factors Sep 09.indd

    African Journals Online (AJOL)

    2009-09-01

    Sep 1, 2009 ... Request for reprints to: Dr. J. B. M. Ddamulira, Makerere University Institute of Public Health P.O. Box 7072, .... Data analysis:SPSS statistical software package version ..... communication change in reducing HIV: Is Uganda.

  6. Tibial and fibular developmental fields defects

    International Nuclear Information System (INIS)

    Khoury, N.J.; Haddad, M.C.; Hourani, M.H.

    1999-01-01

    Malformations of the lower limbs are rare and heterogeneous anomalies. To explain the diversity and complexity of these abnormalities, authors introduced the concept of tibial and fibular developmental fields. Defects in these fields are responsible for different malformations, which have been described, to our knowledge, in only one report in the radiology literature. We present a case of a newborn with femoral bifurcation, absent fibulae and talar bones, ankle and foot malformations, and associated atrial septal defect. Our case is an example of defects in both fibular and tibial developmental fields. (orig.)

  7. Importance of tibial slope for stability of the posterior cruciate ligament deficient knee.

    Science.gov (United States)

    Giffin, J Robert; Stabile, Kathryne J; Zantop, Thore; Vogrin, Tracy M; Woo, Savio L-Y; Harner, Christopher D

    2007-09-01

    Previous studies have shown that increasing tibial slope can shift the resting position of the tibia anteriorly. As a result, sagittal osteotomies that alter slope have recently been proposed for treatment of posterior cruciate ligament (PCL) injuries. Increasing tibial slope with an osteotomy shifts the resting position anteriorly in a PCL-deficient knee, thereby partially reducing the posterior tibial "sag" associated with PCL injury. This shift in resting position from the increased slope causes a decrease in posterior tibial translation compared with the PCL-deficient knee in response to posterior tibial and axial compressive loads. Controlled laboratory study. Three knee conditions were tested with a robotic universal force-moment sensor testing system: intact, PCL-deficient, and PCL-deficient with increased tibial slope. Tibial slope was increased via a 5-mm anterior opening wedge osteotomy. Three external loading conditions were applied to each knee condition at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of knee flexion: (1) 134-N anterior-posterior (A-P) tibial load, (2) 200-N axial compressive load, and (3) combined 134-N A-P and 200-N axial loads. For each loading condition, kinematics of the intact knee were recorded for the remaining 5 degrees of freedom (ie, A-P, medial-lateral, and proximal-distal translations, internal-external and varus-valgus rotations). Posterior cruciate ligament deficiency resulted in a posterior shift of the tibial resting position to 8.4 +/- 2.6 mm at 90 degrees compared with the intact knee. After osteotomy, tibial slope increased from 9.2 degrees +/- 1.0 degrees in the intact knee to 13.8 degrees +/- 0.9 degrees. This increase in slope reduced the posterior sag of the PCL-deficient knee, shifting the resting position anteriorly to 4.0 +/- 2.0 mm at 90 degrees. Under a 200-N axial compressive load with the osteotomy, an additional increase in anterior tibial translation to 2.7 +/- 1.7 mm at 30 degrees was

  8. Res Cover Sep 07

    Indian Academy of Sciences (India)

    THOLASI

    2007-09-19

    Sep 19, 2007 ... Objectives and Structure: The principal objec- tives are to identify and nurture students with special talent in Mathematics. About 30 of the top performers in KRMO are selected for participation in the INMO (Indian National Mathematical Olym- piad). About 30 of the top performers in INMO are awarded a ...

  9. Muscle reinnervation in one or two stages?: experimental study in rats with end-to-side nerve graft Reinervação muscular em um ou dois estágios?: estudo experimental em ratos com enxerto de nervo término-lateral

    Directory of Open Access Journals (Sweden)

    Joseli Assem Bersaneti

    2012-12-01

    Full Text Available PURPOSE: To compare muscle reinnervation in one and two surgical stages using end-to-side neurorrhaphy (ESN without donor nerve injury. METHODS: The experiment was performed on four groups of 20 rats. Group 1 (G1, one stage, received the graft which was sutured to the tibial nerve, with ESN, and its free stump was sutured end-to-end to the distal stump of the sectioned peroneal nerve (PN, all in the same operation. In Group 2 (G2, two stages, the nerve graft was sutured to the tibial nerve, with ESN. Two months later the PN was sectioned and its distal stump connected to the distal stump of the graft as in G1. Normal control group (Gn received the graft only sutured to the tibial nerve, with ESN. Denervated control group (Gd, as well received the graft and had the PN sectioned and its two stumps buried in adjacent musculature, with the aim of denervating the cranial tibial muscle (CTM, the target of this study. The parameters used to evaluate CTM reinnervation were muscle mass, muscle fiber's minimum diameter and area. RESULTS: The mean CTM mass, the average of the muscular fibers areas and the average of the muscular fiber minimum diameters was higher (all pOBJETIVO: Comparar a reinervação muscular com enxerto de nervo em um e dois tempos operatórios, utilizando a neurorrafia término-lateral (NTL sem lesão do nervo doador. MÉTODOS: Vinte ratos foram distribuídos em quatro grupos. O grupo 1 (G1, um estágio, recebeu o enxerto que foi suturado ao nervo tibial (NT, por meio de NTL, e seu coto livre foi suturado por NTL ao coto distal do nervo peroneal (NP, seccionado a um centímetro do NT, na mesma cirurgia. O grupo 2 (G2, dois estágios, recebeu o enxerto de nervo na primeira cirurgia, como já descrito. Dois meses depois, na segunda cirurgia, o NP foi seccionado e seu coto distal ligado ao coto distal do enxerto como em G1. O grupo controle de normalidade (Gn recebeu o enxerto da mesma forma, apenas. E o grupo controle de denerva

  10. Tibial torsion in non-arthritic Indian adults: A computer tomography study of 100 limbs

    Directory of Open Access Journals (Sweden)

    Mullaji Arun

    2008-01-01

    Full Text Available Background: Knowledge of normal tibial torsion is mandatory during total knee replacement (TKR, deformity correction and fracture management of tibia. Different values of tibial torsion have been found in different races due to biological and mechanical factors. Value of normal tibial torsion in Indian limbs is not known, hence this study to determine the norm of tibial torsional value in normal Indian population. Materials and Methods: Computer tomography (CT scans were performed in 100 non-arthritic limbs of 50 Indian adults (42 males, eight females; age 26-40 years. Value of tibial torsion was measured using dorsal tangent to tibial condyles proximally and bimalleolar axis distally. Results: Normal tibial torsion was found to be 21.6 ± 7.6 (range 4.8 to 39.5 with none of the values in internal rotation. Right tibia was externally rotated by 2 degrees as compared to the left side ( P 0.029. No significant difference was found in male and female subjects. Value of tibial torsion was less than in Caucasian limbs, but was comparable to Japanese limbs when studies using similar measurement technique were compared. Conclusions: Indian limbs have less tibial torsion than Caucasian limbs but the value of tibial torsion is comparable to Japanese limbs.

  11. Opening the medial tibiofemoral compartment by pie-crusting the superficial medial collateral ligament at its tibial insertion: a cadaver study.

    Science.gov (United States)

    Roussignol, X; Gauthe, R; Rahali, S; Mandereau, C; Courage, O; Duparc, F

    2015-09-01

    Arthroscopic treatment of tears in the middle and posterior parts of the medial meniscus can be difficult when the medial tibiofemoral compartment is tight. Passage of the instruments may damage the cartilage. The primary objective of this cadaver study was to perform an arthroscopic evaluation of medial tibiofemoral compartment opening after pie-crusting release (PCR) of the superficial medial collateral ligament (sMCL) at its distal insertion on the tibia. The secondary objective was to describe the anatomic relationships at the site of PCR (saphenous nerve, medial saphenous vein). We studied 10 cadaver knees with no history of invasive procedures. The femur was held in a vise with the knee flexed at 45°, and the medial aspect of the knee was dissected. PCR of the sMCL was performed under arthroscopic vision, in the anteroposterior direction, at the distal tibial insertion of the sMCL, along the lower edge of the tibial insertion of the semi-tendinosus tendon. Continuous 300-N valgus stress was applied to the ankle. Opening of the medial tibiofemoral compartment was measured arthroscopically using graduated palpation hooks after sequential PCR of the sMCL. The compartment opened by 1mm after release of the anterior third, 2.3mm after release of the anterior two-thirds, and 3.9mm after subtotal release. A femoral fracture occurred in 1 case, after completion of all measurements. Both the saphenous nerve and the medial saphenous vein were located at a distance from the PCR site in all 10 knees. PCR of the sMCL is chiefly described as a ligament-balancing method during total knee arthroplasty. This procedure is usually performed at the joint line, where it opens the compartment by 4-6mm at the most, with some degree of unpredictability. PCR of the sMCL at its distal tibial insertion provides gradual opening of the compartment, to a maximum value similar to that obtained with PCR at the joint space. The lower edge of the semi-tendinosus tendon is a valuable landmark

  12. Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

    Directory of Open Access Journals (Sweden)

    Karade Vikas

    2012-10-01

    Full Text Available Abstract Background In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. Methods A comparative study of the accuracy of extramedullary and intramedullary tibial cutting guides was carried out in 92 megaprosthetic knee replacements for distal femoral tumors. For the proximal tibia cut for tibial component placement, an extramedullary guide was used in 65 patients and an intramedullary guide was used in 27 patients. Tibial component alignment angles were measured in postoperative X-rays with the help of CAD software. Results There was more varus placement in coronal plane with extramedullary cutting guide (−1.18 +/− 2.4 degrees than the intramedullary guide (−0.34 +/− 2.31 degrees but this did not reach statistical significance. The goal of 90 +/− 2 degrees alignment of tibial component was achieved in 54% of patients in the extramedullary group versus 67% in the intramedullary group. In terms of sagittal plane alignment, extramedullary guide showed less accurate results (2.09 +/− 2.4 degrees than intramedullary guide (0.50 +/− 3.80 degrees for tibial component alignment, though 78% of patients were aligned within the goal of 0–5 degrees of tibial slope angle in extramedullary group versus 63% in intramedullary group. The mean error in the measurements due to rotation of the knee during taking the X-rays was less than 0.1 degrees and distribution of the X-rays with the rotation of knee was similar in both the groups. Conclusions Overall, in megaprosthetic knee replacement intramedullary guides gave more accurate results in sagittal plane and exhibited similar variability as of extramedullary guides in coronal plane.

  13. Space Weather at Mars: MAVEN and MSL/RAD Observations of CME and SEP Events

    Science.gov (United States)

    Lee, C. O.; Ehresmann, B.; Lillis, R. J.; Dunn, P.; Rahmati, A.; Larson, D. E.; Guo, J.; Zeitlin, C.; Luhmann, J. G.; Halekas, J. S.; Espley, J. R.; Thiemann, E.; Hassler, D.

    2017-12-01

    While MAVEN have been observing the space weather conditions driven by ICMEs and SEPs in orbit around Mars, MSL/RAD have been measuring the surface radiation environment due to E > 150 MeV/nuc SEPs and the higher-energy galactic cosmic rays. The suite of MAVEN instruments measuring the particles (SEP), plasma (SWIA) and fields (MAG) information provides detailed local space weather information regarding the solar activity-related fluctuations in the measured surface dose rates. At the same time, the related enhancements in the RAD surface dose rates indicate the degree to which the SEPs affect the lower atmosphere and surface. We will present an overview of the MAVEN observations together with the MSL/RAD measurements and focus our discussion on a number of space weather events driven by CMEs and SEPs. During the March 2015 solar storm period, a succession of CMEs produced intense SEP proton fluxes that were detected by MAVEN/SEP in the 20 keV to 6 MeV detected energy channels. At higher energies, MAVEN/SEP record `FTO' SEP events that were triggered by > 13 MeV energetic protons passing through all three silicon detector layers (Front, Thick, and Open). Using the detector response matrix for an FTO event (incident energy vs detected energy), the minimum incident energy of the SEP protons observed in March 2015 was inferred to be > 40 MeV. The lack of any notable enhancements in the surface dose rate by MSL/RAD suggests that the highest incident energies of the SEP protons were 150 MeV SEP protons impacted the Martian atmosphere and surface. The source of the October 2015 SEP event was probably the CME that erupted near the solar west limb with respect to the Sun-Mars line. As part of the discussion, we will also show solar-heliospheric observations from near-Earth assets together with WSA-Enlil-cone results for some global heliospheric context.

  14. Using Dawn to Observe SEP Events Past 2 AU

    Science.gov (United States)

    Villarreal, M. N.; Russell, C. T.; Prettyman, T. H.

    2017-12-01

    The launch of the STEREO spacecraft provided much insight into the longitudinal and radial distribution of solar energetic particles (SEPs) relative to their origin site. However, almost all of the observations of SEP events have been made exclusively near 1 AU. The Dawn mission, which orbited around Vesta before arriving at Ceres, provides an opportunity to analyze these events at much further distances. Although Dawn's Gamma Ray and Neutron Detector (GRaND) is not optimized for SEP characterization, it is sensitive to protons greater than 4 MeV, making it capable of detecting a solar energetic particle event in its vicinity. Solar energetic particles in this area of the solar system are important as they are believed to cause sputtering at bodies such as Ceres and comets (Villarreal et al., 2017; Wurz et al., 2015). In this study, we use Dawn's GRaND data from 2011-2015 when Dawn was at distances between 2-3 AU. We compare the SEP events seen by Dawn with particle measurements at 1 AU using STEREO, Wind, and ACE to understand how the SEP events evolved past 1 AU.References: Villarreal, M. N., et al. (2017), The dependence of the Cerean exosphere on solar energetic particle events, Astrophys. J. Lett., 838, L8.Wurz, P. et al. (2015), Solar wind sputtering of dust on the surface of 67P/Churyumov-Gerasimenko, A&A, 583, A22.

  15. Peak stresses shift from femoral tunnel aperture to tibial tunnel aperture in lateral tibial tunnel ACL reconstructions: a 3D graft-bending angle measurement and finite-element analysis.

    Science.gov (United States)

    Van Der Bracht, Hans; Tampere, Thomas; Beekman, Pieter; Schepens, Alexander; Devriendt, Wouter; Verdonk, Peter; Victor, Jan

    2018-02-01

    To investigate the effect of tibial tunnel orientation on graft-bending angle and stress distribution in the ACL graft. Eight cadaveric knees were scanned in extension, 45°, 90°, and full flexion. 3D reconstructions with anatomically placed anterior cruciate ligament (ACL) grafts were constructed with Mimics 14.12 ® . 3D graft-bending angles were measured for classic medial tibial tunnels (MTT) and lateral tibial tunnels (LTT) with different drill-guide angles (DGA) (45°, 55°, 65°, and 75°). A pivot shift was performed on 1 knee in a finite-element analysis. The peak stresses in the graft were calculated for eight different tibial tunnel orientations. In a classic anatomical ACL repair, the largest graft-bending angle and peak stresses are seen at the femoral tunnel aperture. The use of a different DGA at the tibial side does not change the graft-bending angle at the femoral side or magnitude of peak stresses significantly. When using LTT, the largest graft-bending angles and peak stresses are seen at the tibial tunnel aperture. In a classic anatomical ACL repair, peak stresses in the ACL graft are found at the femoral tunnel aperture. When an LTT is used, peak stresses are similar compared to classic ACL repairs, but the location of the peak stress will shift from the femoral tunnel aperture towards the tibial tunnel aperture. the risk of graft rupture is similar for both MTTs and LTTs, but the location of graft rupture changes from the femoral tunnel aperture towards the tibial tunnel aperture, respectively. I.

  16. tibialization of the fibula in a child with chronic osteomyelitis of the ...

    African Journals Online (AJOL)

    used in tibial reconstruction after resection of Ewing's sarcoma (6). A case report from Congo detailed how a 10-centimeter tibial bone loss was treated by inter- tibiofibula bone grafting, resulting in tibialization of the fibula. The patient was reviewed after 10 years; and the clinical result was satisfactory and stable (7).

  17. Role of the brain stem in tibial inhibition of the micturition reflex in cats.

    Science.gov (United States)

    Ferroni, Matthew C; Slater, Rick C; Shen, Bing; Xiao, Zhiying; Wang, Jicheng; Lee, Andy; Roppolo, James R; de Groat, William C; Tai, Changfeng

    2015-08-01

    This study examined the role of the brain stem in inhibition of bladder reflexes induced by tibial nerve stimulation (TNS) in α-chloralose-anesthetized decerebrate cats. Repeated cystometrograms (CMGs) were performed by infusing saline or 0.25% acetic acid (AA) to elicit normal or overactive bladder reflexes, respectively. TNS (5 or 30 Hz) at three times the threshold (3T) intensity for inducing toe movement was applied for 30 min between CMGs to induce post-TNS inhibition or applied during the CMGs to induce acute TNS inhibition. Inhibition was evident as an increase in bladder capacity without a change in amplitude of bladder contractions. TNS applied for 30 min between saline CMGs elicited prolonged (>2 h) poststimulation inhibition that significantly (P reflexes but are not involved in inhibition of normal bladder reflexes. Copyright © 2015 the American Physiological Society.

  18. The energetic relationship among geoeffective solar flares, associated CMEs and SEPs

    International Nuclear Information System (INIS)

    Bhatt Nipa J; Jain Rajmal; Awasthi Arun Kumar

    2013-01-01

    Major solar eruptions (flares, coronal mass ejections (CMEs) and solar energetic particles (SEPs)) strongly influence geospace and space weather. Currently, the mechanism of their influence on space weather is not well understood and requires a detailed study of the energetic relationship among these eruptive phenomena. From this perspective, we investigate 30 flares (observed by RHESSI), followed by weak to strong geomagnetic storms. Spectral analysis of these flares suggests a new power-law relationship (r ∼ 0.79) between the hard X-ray (HXR) spectral index (before flare-peak) and linear speed of the associated CME observed by LASCO/SOHO. For 12 flares which were followed by SEP enhancement near Earth, HXR and SEP spectral analysis reveals a new scaling law (r ∼ 0.9) between the hardest X-ray flare spectrum and the hardest SEP spectrum. Furthermore, a strong correlation is obtained between the linear speed of the CME and the hardest spectrum of the corresponding SEP event (r ∼ 0.96). We propose that the potentially geoeffective flare and associated CME and SEP are well-connected through a possible feedback mechanism, and should be regarded within the framework of a solar eruption. Owing to their space weather effects, these new results will help improve our current understanding of the Sun-Earth relationship, which is a major goal of research programs in heliophysics

  19. Comparison of tibial shaft ski fractures in children and adults.

    Science.gov (United States)

    Hamada, Tomo; Matsumoto, Kazu; Ishimaru, Daichi; Sumi, Hiroshi; Shimizu, Katsuji

    2014-09-01

    To examine whether child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures. Descriptive epidemiological study. Prospectively analyzed the epidemiologic factors, injury types, and injury mechanisms at Sumi Memorial Hospital. This study analyzed information obtained from 276 patients with tibial fractures sustained during skiing between 2004 and 2012. We focused on 174 ski-related tibial shaft fractures with respect to the following factors: age, gender, laterality of fracture, skill level, mechanism of fracture (fall vs collision), scene of injury (steepness of slope), snow condition, and weather. Fracture pattern was graded according to Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification and mechanical direction [external (ER) or internal rotation (IR)]. Tibial shaft fractures were the most common in both children (89.3%) and adults (47.4%). There were no significant differences in gender, side of fracture, mechanism of fracture, snow condition, or weather between children and adults. Skill levels were significantly lower in children than in adults (P differences in some of these parameters, suggesting that child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures.

  20. EAMJ Diagnosis Sep 09.indd

    African Journals Online (AJOL)

    2009-09-01

    Sep 1, 2009 ... East African Medical Journal Vol. 86 No. 9 September 2009. DIAGNOSIS OF DUAL HUMAN IMMUNODEFICIENCY VIRUS TYPES 1 AND 2 INFECTIONS IN A RESOURCE-. LIMITED SETTING. K. W. C. Sagoe, MSc, Lecturer, Department of Microbiology (Clinical Virology Laboratory), University of Ghana ...

  1. All-Polyethylene Tibial Components: An Analysis of Long-Term Outcomes and Infection.

    Science.gov (United States)

    Houdek, Matthew T; Wagner, Eric R; Wyles, Cody C; Watts, Chad D; Cass, Joseph R; Trousdale, Robert T

    2016-07-01

    There is debate regarding tibial component modularity and composition in total knee arthroplasty (TKA). Biomechanical studies have suggested improved stress distribution in metal-backed tibias; however, these results have not translated clinically. The purpose of this study was to analyze the outcomes of all-polyethylene components and to compare the results to those with metal-backed components. We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970-2013). There were 28,224 (88%) metal-backed and 3715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to gender, age and body mass index (BMI). Mean follow-up was 7 years. The mean survival for all primary TKAs at the 5-, 10-, 20- and 30-year time points was 95%, 89%, 73%, and 57%, respectively. All-polyethylene tibial components were found to have a significantly improved (P tibial components were also found to have a significantly lower rate of infection, instability, tibial component loosening, and periprosthetic fracture. The all-polyethylene group had improved survival rates in all age groups, except in patients 85 years old or greater, where there was no significant difference. All-polyethylene tibial components had improved survival for all BMI groups except in the morbidly obese (BMI ≥ 40) where there was no significant difference. All-polyethylene tibial components had significantly improved implant survival, reduced rates of postoperative infection, fracture, and tibial component loosening. All polyethylene should be considered for most of the patients, regardless of age and BMI. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Differential vulnerability of 3 rapidly conducting somatosensory pathways in the dog with vitamin B6 neuropathy.

    Science.gov (United States)

    Schaeppi, U; Krinke, G

    1985-09-01

    In anesthetized dogs with chronically implanted cortical electrodes somatic sensory-evoked potentials (SEPs) were produced by electrical stimulation at neural, muscular or cutaneous sites of the contralateral hind leg. Stimulation of the tibial nerve at the calcaneus or of the short flexor muscles of the hind paw caused SEPs having characteristics following activation of rapidly conducting afferents from muscle spindles. Stimulation of the glabrous skin of the central pad resulted in SEPs arriving after a more protracted latency evidently related to activation of afferents from Merkel cells, Krause and Pacinian corpuscles known to be located at these sites. Stimulation of the hairy skin from the dorsal surface of the hindpaw produced a further type of SEP presumably resulting from activation of afferents from receptors of tylotrich hair follicles. Vitamin B6-induced neuropathy involves the selective degeneration of the largest neurons in the spinal ganglia and of associated long peripheral and central neurites performing rapid impulse transmission. In the course of vitamin B6 neuropathy the relatively slow impulse transmission following stimulation of the central pad was more severely impaired than the faster one after activation of afferents from muscle spindles or receptors from hair follicles. This allows us to conclude that in the dog afferents from the glabrous skin of the central pad conduct centrally via the dorsal columns, susceptible to vitamin B6 intoxication, while muscle and hair receptor afferents ascend in the dorsal spinocerebellar and spinocervical tract, respectively, which are vitamin B6 resistant.

  3. External fixation of tibial pilon fractures and fracture healing.

    Science.gov (United States)

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  4. Anterior cruciate ligament reconstruction failure after tibial shaft malunion.

    Science.gov (United States)

    LaFrance, Russell M; Gorczyca, John T; Maloney, Michael D

    2012-02-17

    Anterior cruciate ligament (ACL) reconstruction is common, with >100,000 procedures performed each year in the United States. Several factors are associated with failure, including poor surgical technique, graft incorporation failure, overly aggressive rehabilitation, and trauma. Tibial shaft fracture is also common and frequently requires operative intervention. Failure to reestablish the anatomic alignment of the tibia may cause abnormal forces across adjacent joints, which can cause degenerative joint disease or attritional failure of the surrounding soft tissues. This article describes a case of ACL reconstruction failure after a tibial fracture that resulted in malunion. Excessive force across the graft from lower-extremity malalignment and improper tunnel placement likely contributed to the attritional failure of the graft. This patient required a staged procedure for corrective tibial osteotomy followed by revision ACL reconstruction. This article describes ACL reconstruction failure, tibial shaft malunions, their respective treatments, the technical details of each procedure, and the technical aspects that must be considered when these procedures are done in a staged manner by 2 surgeons. Copyright 2012, SLACK Incorporated.

  5. Impact of Fixed-Bearing and Mobile-Bearing Tibial Insert in Unicondylar Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Mehmet Faruk Çatma

    2016-06-01

    Full Text Available INTRODUCTION: The aim of the study is to investigate the impact of fixed or mobile-bearing tibial inserts on patellofemoral arthrosis and evaluate which one to be preferred for patients with patellofemoral arthrosis. METHODS: Operated in our clinic between January 2009 and February 2013, 33 with patellofemoral arthritis together with anteromedial compartment arthritis were included in the study. Patellofemoral joints of patients were evaluated according to the scoring system defined by Fulkerson-Shea. RESULTS: Unicondylar knee arthroplasty with fixed-bearing tibial insertsand 22 (66,6% (male: 3, female: 19 and unicondylar knee arthroplasty with mobile-bearing tibial inserts 11 (33,9 % (male: 2, female: 9 were implanted.Average knee flexion was found to be 116,5 (100-135 degrees in 22 patients with mobile-bearing tibial inserts, and 114,5 (95-135 in 11 patients with fixed-bearing tibial inserts. DISCUSSION AND CONCLUSION: Patellofemoral arthrosis is an important factor for unicondylar knee arthroplasty prognosis and one of the determinants of patient satisfaction. Significantly less patellofemoral complaints were seen with UKA with fixed-bearing tibial insert compared to mobile-bearing tibial insert.

  6. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study

    OpenAIRE

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-ichi

    2017-01-01

    AIM To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). METHODS A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fract...

  7. Primary Ankle Arthrodesis for Severely Comminuted Tibial Pilon Fractures.

    Science.gov (United States)

    Al-Ashhab, Mohamed E

    2017-03-01

    Management of severely comminuted, complete articular tibial pilon fractures (Rüedi and Allgöwer type III) remains a challenge, with few treatment options providing good clinical outcomes. Twenty patients with severely comminuted tibial pilon fractures underwent primary ankle arthrodesis with a retrograde calcaneal nail and autogenous fibular bone graft. The fusion rate was 100% and the varus malunion rate was 10%. Fracture union occurred at a mean of 16 weeks (range, 13-18 weeks) postoperatively. Primary ankle arthrodesis is a successful method for treating highly comminuted tibial pilon fractures, having a low complication rate and a high satisfaction score. [Orthopedics. 2017; 40(2):e378-e381.]. Copyright 2016, SLACK Incorporated.

  8. Effects of age and insulin-like growth factor-1 on rat neurotrophin receptor expression after nerve injury.

    Science.gov (United States)

    Luo, T David; Alton, Timothy B; Apel, Peter J; Cai, Jiaozhong; Barnwell, Jonathan C; Sonntag, William E; Smith, Thomas L; Li, Zhongyu

    2016-10-01

    Neurotrophin receptors, such as p75(NTR) , direct neuronal response to injury. Insulin-like growth factor-1 receptor (IGF-1R) mediates the increase in p75(NTR) during aging. The aim of this study was to examine the effect of aging and insulin-like growth factor-1 (IGF-1) treatment on recovery after peripheral nerve injury. Young and aged rats underwent tibial nerve transection with either local saline or IGF-1 treatment. Neurotrophin receptor mRNA and protein expression were quantified. Aged rats expressed elevated baseline IGF-1R (34% higher, P = 0.01) and p75(NTR) (68% higher, P < 0.01) compared with young rats. Post-injury, aged animals expressed significantly higher p75(NTR) levels (68.5% above baseline at 4 weeks). IGF-1 treatment suppressed p75(NTR) gene expression at 4 weeks (17.2% above baseline, P = 0.002) post-injury. Local IGF-1 treatment reverses age-related declines in recovery after peripheral nerve injuries by suppressing p75(NTR) upregulation and pro-apoptotic complexes. IGF-1 may be considered a viable adjuvant therapy to current treatment modalities. Muscle Nerve 54: 769-775, 2016. © 2016 Wiley Periodicals, Inc.

  9. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  10. Safe surgical technique: intramedullary nail fixation of tibial shaft fractures.

    Science.gov (United States)

    Zelle, Boris A; Boni, Guilherme

    2015-01-01

    Statically locked, reamed intramedullary nailing remains the standard treatment for displaced tibial shaft fractures. Establishing an appropriate starting point is a crucial part of the surgical procedure. Recently, suprapatellar nailing in the semi-extended position has been suggested as a safe and effective surgical technique. Numerous reduction techiques are available to achieve an anatomic fracture alignment and the treating surgeon should be familiar with these maneuvers. Open reduction techniques should be considered if anatomic fracture alignment cannot be achieved by closed means. Favorable union rates above 90 % can be achieved by both reamed and unreamed intramedullary nailing. Despite favorable union rates, patients continue to have functional long-term impairments. In particular, anterior knee pain remains a common complaint following intramedullary tibial nailing. Malrotation remains a commonly reported complication after tibial nailing. The effect of postoperative tibial malalignment on the clinical and radiographic outcome requires further investigation.

  11. MR imaging findings of medial tibial crest friction

    International Nuclear Information System (INIS)

    Klontzas, Michail E.; Akoumianakis, Ioannis D.; Vagios, Ilias; Karantanas, Apostolos H.

    2013-01-01

    Objective: Medial tibial condyle bone marrow edema (BME), associated with soft tissue edema (STe) surrounding the medial collateral ligament, was incidentally observed in MRI examinations of young and athletic individuals. The aim of the present study was to 1. Prospectively investigate the association between these findings and coexistence of localized pain, and 2. Explore the possible contribution of the tibial morphology to its pathogenesis. Methods: The medial tibial condyle crest was evaluated in 632 knee MRI examinations. The angle and depth were measured by two separate evaluators. The presence of STe and BME was recorded. A third evaluator blindly assessed the presence of pain at this site. Results: BME associated with STe was found in 24 patients (with no history of previous trauma, osteoarthritis, tumor or pes anserine bursitis). The mean crest angle was 151.3° (95%CI 147.4–155.3°) compared to 159.4° (95%CI 158.8–160°) in controls (Mann–Whitney test, P < 0.0001). MRI findings were highly predictive of localized pain (sensitivity 92% specificity 99%, Fisher's exact test, P < 0.0001). Conclusion: Friction at the medial tibial condyle crest is a painful syndrome. MRI is a highly specific and sensitive imaging modality for its diagnosis

  12. Contact Stress Generation on the UHMWPE Tibial Insert

    Directory of Open Access Journals (Sweden)

    S. Petrović Savić

    2014-12-01

    Full Text Available Total knee replacement (TKR is considered, during last years, as a very successful surgical technique for removing knee joint deformities and eliminating pain caused by cartilage damage. In literature, as primary causes for knee joint endoprothesis damage are cited complex movements which cause occurrences of complex stress conditions, sagital radius conformity, sliding, types of materials etc. Aim of this study is analysis of contact stresses that occur on tibial implant for 15°, 45° and 60° knee flexion and 50 kg, 75 kg, 100 kg and 125 kg weight. Knee joint prosthesis model and finite elements method (FEM analysis are done in software Catia V5. For this analysis we used ultra-high molecular weight polyethylene (UHMWPE for tibial implant material and AISI 316, AISI 317, AISI 321, 17-4PH, CoCrMo, Ti6Al4V and SAE A-286 for femoral component materials. Results show that area of maximal contact stress is identified in medial and lateral part of tibial implant. Von Mises stress values vary regarding of flexion degree and weight, but values are approximate for types of chosen materials. Contact stress location corresponds to damage that occur on tibial implant during exploitation.

  13. MR imaging findings of medial tibial crest friction

    Energy Technology Data Exchange (ETDEWEB)

    Klontzas, Michail E., E-mail: miklontzas@gmail.com; Akoumianakis, Ioannis D., E-mail: ioannis.akoumianakis@gmail.com; Vagios, Ilias, E-mail: iliasvagios@gmail.com; Karantanas, Apostolos H., E-mail: akarantanas@gmail.com

    2013-11-01

    Objective: Medial tibial condyle bone marrow edema (BME), associated with soft tissue edema (STe) surrounding the medial collateral ligament, was incidentally observed in MRI examinations of young and athletic individuals. The aim of the present study was to 1. Prospectively investigate the association between these findings and coexistence of localized pain, and 2. Explore the possible contribution of the tibial morphology to its pathogenesis. Methods: The medial tibial condyle crest was evaluated in 632 knee MRI examinations. The angle and depth were measured by two separate evaluators. The presence of STe and BME was recorded. A third evaluator blindly assessed the presence of pain at this site. Results: BME associated with STe was found in 24 patients (with no history of previous trauma, osteoarthritis, tumor or pes anserine bursitis). The mean crest angle was 151.3° (95%CI 147.4–155.3°) compared to 159.4° (95%CI 158.8–160°) in controls (Mann–Whitney test, P < 0.0001). MRI findings were highly predictive of localized pain (sensitivity 92% specificity 99%, Fisher's exact test, P < 0.0001). Conclusion: Friction at the medial tibial condyle crest is a painful syndrome. MRI is a highly specific and sensitive imaging modality for its diagnosis.

  14. Local and Widespread Hyperalgesia After Isolated Tibial Shaft Fractures Treated with Intramedullary Nailing

    DEFF Research Database (Denmark)

    Larsen, Peter; Elsøe, Rasmus; Graven-Nielsen, Thomas

    2016-01-01

    OBJECTIVES: Knee pain is accepted as a common complication to intramedullary nailing of tibial fractures. However, no studies have systematically studied the pain sequel following tibial fractures. The objective of this study was to assess pain and hyperalgesia from 6 weeks to 12 months postopera...... fracture treated with intramedullary nailing, although no widespread (extrasegmental) hyperalgesia was detected. Such observations may be important for developing the most adequate rehabilitation procedure following a tibial fracture.......OBJECTIVES: Knee pain is accepted as a common complication to intramedullary nailing of tibial fractures. However, no studies have systematically studied the pain sequel following tibial fractures. The objective of this study was to assess pain and hyperalgesia from 6 weeks to 12 months...... postoperatively after intramedullary nailing of tibial shaft fracture. METHODS: A total of 39 patients were included in this 12-month follow-up study. After 6 weeks, 3, 6, and 12 months postoperatively the pain intensity was measured on a visual analog scale (VAS) and the pressure pain sensitivity was assessed...

  15. Longitudinal tibial epiphyseal bracket in Nievergelt syndrome

    International Nuclear Information System (INIS)

    Burnstein, M.I.; De Smet, A.A.; Breed, A.L.; Thomas, J.R.; Hafez, G.R.

    1989-01-01

    A patient is described with lower extremity mesomelic dwarfism associated with bilateral congenital elbow, hip, and knee dislocations. Rhomboid-shaped tibiae and delayed ossification of the primary fibular ossification centers were demonstrated at birth. Plain films and magnetic resonance imaging revealed that the tibial deformities were due to the presence of longitudinal epiphyseal brackets. These brackets were observed at surgery and confirmed histologically. Recognition of the longitudinal epiphyseal bracket and its relationship to the tibial deformities seen in this patient with Nievergelt syndrome is important for planning surgical treatment. (orig.)

  16. Longitudinal tibial epiphyseal bracket in Nievergelt syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Burnstein, M.I.; De Smet, A.A.; Breed, A.L.; Thomas, J.R.; Hafez, G.R.

    1989-04-01

    A patient is described with lower extremity mesomelic dwarfism associated with bilateral congenital elbow, hip, and knee dislocations. Rhomboid-shaped tibiae and delayed ossification of the primary fibular ossification centers were demonstrated at birth. Plain films and magnetic resonance imaging revealed that the tibial deformities were due to the presence of longitudinal epiphyseal brackets. These brackets were observed at surgery and confirmed histologically. Recognition of the longitudinal epiphyseal bracket and its relationship to the tibial deformities seen in this patient with Nievergelt syndrome is important for planning surgical treatment. (orig.).

  17. Double muscle innervation using end-to-side neurorrhaphy in rats

    Directory of Open Access Journals (Sweden)

    Elisangela Jeronymo Stipp-Brambilla

    Full Text Available CONTEXT AND OBJECTIVE: One of the techniques used for treating facial paralysis is double muscle innervation using end-to-end neurorrhaphy with sectioning of healthy nerves. The aim of this study was to evaluate whether double muscle innervation by means of end-to-side neurorrhaphy could occur, with maintenance of muscle innervation. DESIGN AND SETTING: Experimental study developed at the Experimental Research Center, Faculdade de Medicina de Botucatu, Unesp. METHODS: One hundred rats were allocated to five groups as follows: G1, control group; G2, the peroneal nerve was sectioned; G3, the tibial nerve was transected and the proximal stump was end-to-side sutured to the intact peroneal nerve; G4, 120 days after the G3 surgery, the peroneal nerve was sectioned proximally to the neurorrhaphy; G5, 120 days after the G3 surgery, the peroneal and tibial nerves were sectioned proximally to the neurorrhaphy. RESULTS: One hundred and fifty days after the surgery, G3 did not show any change in tibial muscle weight or muscle fiber diameter, but the axonal fiber diameter in the peroneal nerve distal to the neurorrhaphy had decreased. Although G4 showed atrophy of the cranial tibial muscle 30 days after sectioning the peroneal nerve, the electrophysiological test results and axonal diameter measurement confirmed that muscle reinnervation had occurred. CONCLUSION: These findings suggest that double muscle innervation did not occur through end-to-side neurorrhaphy; the tibial nerve was not able to maintain muscle innervation after the peroneal nerve had been sectioned, although muscle reinnervation was found to have occurred, 30 days after the peroneal nerve had been sectioned.

  18. The Dependence of Characteristic Times of Gradual SEP Events on Their Associated CME Properties

    Science.gov (United States)

    Pan, Z. H.; Wang, C. B.; Xue, X. H.; Wang, Y. M.

    It is generally believed that coronal mass ejections CMEs are the drivers of shocks that accelerate gradual solar energetic particles SEPs One might expect that the characteristics of the SEP intensity time profiles observed at 1 AU are determined by properties of the associated CMEs such as the radial speed and the angular width Recently Kahler statistically investigated the characteristic times of gradual SEP events observed from 1998-2002 and their associated coronal mass ejection properties Astrophys J 628 1014--1022 2005 Three characteristic times of gradual SEP events are determined as functions of solar source longitude 1 T 0 the time from associated CME launch to SEP onset at 1 AU 2 T R the rise time from SEP onset to the time when the SEP intensity is a factor of 2 below peak intensity and 3 T D the duration over which the SEP intensity is within a factor of 2 of the peak intensity However in his study the CME speeds and angular widths are directly taken from the LASCO CME catalog In this study we analyze the radial speeds and the angular widths of CMEs by an ice-cream cone model and re-investigate their correlationships with the characteristic times of the corresponding SEP events We find T R and T D are significantly correlated with radial speed for SEP events in the best-connected longitude range and there is no correlation between T 0 and CME radial speed and angular width which is consistent with Kahler s results On the other hand it s found that T R and T D are also have

  19. MRI-validation of SEP monitoring for ischemic events during microsurgical clipping of intracranial aneurysms.

    Science.gov (United States)

    Krayenbühl, Niklaus; Sarnthein, Johannes; Oinas, Minna; Erdem, Eren; Krisht, Ali F

    2011-09-01

    During surgical clipping of intracranial aneurysms, reduction in SEP amplitude is thought to indicate cortical ischemia and subsequent neurological deficits. Since the sensitivity of SEP is questioned, we investigated SEP with respect to post-operative ischemia. In 36 patients with 51 intracranial aneurysms, clinical evaluation and diffusion-weighted MRI (DWI) was performed before and within 24h after surgery. During surgery, time of temporary occlusion was recorded. MRI images were reviewed for signs of ischemia. For 43 clip applications (84%), we observed neither pathologic SEP events nor ischemia in MRI. In two cases where reduction lasted >10 min after clip release, SEP events correlated with ischemia in the MRI. Only one of the ischemic patients was symptomatic and developed a transient hemiparesis. While pathologic SEP events correlated with visible ischemia in MRI only in two cases with late SEP recovery, ischemia in MRI may have been transient or may not have reached detection threshold in the other cases, in agreement with the absence of permanent neurological deficits. In complex aneurysm cases, where prolonged temporary occlusion is expected, SEP should be used to detect ischemia at a reversible stage to improve the safety of aneurysm clipping. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Complex Medial Meniscus Tears Are Associated With a Biconcave Medial Tibial Plateau.

    Science.gov (United States)

    Barber, F Alan; Getelman, Mark H; Berry, Kathy L

    2017-04-01

    To determine whether an association exists between a biconcave medial tibial plateau and complex medial meniscus tears. A consecutive series of stable knees undergoing arthroscopy were evaluated retrospectively with the use of preoperative magnetic resonance imaging (MRI), radiographs, and arthroscopy documented by intraoperative videos. Investigators independently performed blinded reviews of the MRI or videos. Based on the arthroscopy findings, medial tibial plateaus were classified as either biconcave or not biconcave. A transverse coronal plane ridge, separating the front of the tibial plateau from the back near the inner margin of the posterior body of the medial meniscus, was defined as biconcave. The medial plateau slope was calculated with MRI sagittal views. General demographic information, body mass index, and arthroscopically confirmed knee pathology were recorded. A total of 179 consecutive knees were studied from July 2014 through August 2015; 49 (27.2%) biconcave medial tibial plateaus and 130 (72.8%) controls were identified at arthroscopy. Complex medial meniscus tears were found in 103. Patients with a biconcave medial tibial plateau were found to have more complex medial meniscus tears (69.4%) than those without a biconcavity (53.1%) (P = .049) despite having lower body mass index (P = .020). No difference in medial tibial plateau slope was observed for biconcavities involving both cartilage and bone, bone only, or an indeterminate group (P = .47). Biconcave medial tibial plateaus were present in 27.4% of a consecutive series of patients undergoing knee arthroscopy. A biconcave medial tibial plateau was more frequently associated with a complex medial meniscus tear. Level III, case-control study. Copyright © 2016 Arthroscopy Association of North America. All rights reserved.

  1. Preventing lower cranial nerve injuries during fourth ventricle tumor resection by utilizing intraoperative neurophysiological monitoring.

    Science.gov (United States)

    Jahangiri, Faisal R; Minhas, Mazhar; Jane, John

    2012-12-01

    We present two cases illustrating the benefit of utilizing intraoperative neurophysiological monitoring (IONM) for prevention of injuries to the lower cranial nerves during fourth ventricle tumor resection surgeries. Multiple cranial nerve nuclei are located on the floor of the fourth ventricle with a high risk of permanent damage. Two male patients (ages 8 and 10 years) presented to the emergency department and had brain magnetic resonance imaging (MRI) scans showing brainstem/fourth ventricle tumors. During surgery, bilateral posterior tibial and median nerve somatosensory evoked potentials (SSEPs); four-limb and cranial nerves transcranial electrical motor evoked potentials (TCeMEPs); brainstem auditory evoked responses (BAERs); and spontaneous electromyography (s-EMG) were recorded. Electromyography (EMG) was monitored bilaterally from cranial nerves V VII, IX, X, XI, and XII. Total intravenous anesthesia was used. Neuromuscular blockade was used only for initial intubation. Pre-incision baselines were obtained with good morphology of waveforms. After exposure the floor of the fourth ventricle was mapped by triggered-EMG (t-EMG) using 0.4 to 1.0 mA. In both patients the tumor was entangled with cranial nerves VII to XII on the floor of the fourth ventricle. The surgeon made the decision not to resect the tumor in one case and limited the resection to 70% of the tumor in the second case on the basis of neurophysiological monitoring. This decision was made to minimize any post-operative neurological deficits due to surgical manipulation of the tumor involving the lower cranial nerves. Intraoperative spontaneous and triggered EMG was effectively utilized in preventing injuries to cranial nerves during surgical procedures. All signals remained stable during the surgical procedure. Postoperatively both patients were well with no additional cranial nerve weakness. At three months follow-up, the patients continued to have no deficits.

  2. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures.

    Science.gov (United States)

    Houben, I B; Raaben, M; Van Basten Batenburg, M; Blokhuis, T J

    2018-04-09

    The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16-89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. 3b.

  3. Automated characterization of nerve fibers labeled fluorescently: determination of size, class and spatial distribution.

    Science.gov (United States)

    Prodanov, Dimiter; Feirabend, Hans K P

    2008-10-03

    Morphological classification of nerve fibers could help interpret the assessment of neural regeneration and the understanding of selectivity of nerve stimulation. Specific populations of myelinated nerve fibers can be investigated by retrograde tracing from a muscle followed by microscopic measurements of the labeled fibers at different anatomical levels. Gastrocnemius muscles of adult rats were injected with the retrograde tracer Fluoro-Gold. After a survival period of 3 days, cross-sections of spinal cords, ventral roots, sciatic, and tibial nerves were collected and imaged on a fluorescence microscope. Nerve fibers were classified using a variation-based criterion acting on the distribution of their equivalent diameters. The same criterion was used to classify the labeled axons using the size of the fluorescent marker. Measurements of the axons were paired to those of the entire fibers (axons+myelin sheaths) in order to establish the correspondence between so-established axonal and fiber classifications. It was found that nerve fibers in L6 ventral roots could be classified into four populations comprising two classes of Aalpha (denoted Aalpha1 and Aalpha2), Agamma, and an additional class of Agammaalpha fibers. Cut-off borders between Agamma and Agammaalpha fiber classes were estimated to be 5.00+/-0.09 microm (SEM); between Agammaalpha and Aalpha1 fiber classes to be 6.86+/-0.11 microm (SEM); and between Aalpha1 and Aalpha2 fiber classes to be 8.66+/-0.16 microm (SEM). Topographical maps of the nerve fibers that innervate the gastrocnemius muscles were constructed per fiber class for the spinal root L6. The major advantage of the presented approach consists of the combined indirect classification of nerve fiber types and the construction of topographical maps of so-identified fiber classes.

  4. Tibial tunnel and pretibial cysts following ACL graft reconstruction: MR imaging diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ghazikhanian, Varand [Brigham and Women' s Hospital, Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Beltran, Javier [Maimonides Medical Center, Brooklyn, NY (United States); Nikac, Violeta [Maimonides Medical Center, Department of Radiology, Brooklyn, NY (United States); Bencardino, Jenny T. [NYU Hospital for Joint Diseases, New York, NY (United States); Feldman, Marina

    2012-11-15

    Tunnel cyst formation is a rare complication after anterior cruciate ligament reconstruction, usually occurring 1-5 years post-operatively, which may occasionally be symptomatic. There are multiple proposed theories regarding the etiology of tunnel cysts. Theories include necrosis, foreign-body reaction, lack of complete graft osteo-integration, and intravasation of articular fluid. It is important to know if the tunnel cysts are communicating or not communicating with the joint, as surgical management may be different. Imaging characteristics on magnetic resonance images (MRI) include tibial tunnel widening, multilocular or unilocular cyst formation in the graft or tibial tunnel, with possible extension into the pretibial space, intercondylar notch, and/or popliteal fossa. The MR imaging differential diagnosis of tibial tunnel cysts includes infection, foreign-body granuloma, or tibial screw extrusion. Importantly, to the best of our knowledge, graft failure or instability has not been reported in association with tibial tunnel cysts. (orig.)

  5. The medial tibial stress syndrome score: Item generation for a new ...

    African Journals Online (AJOL)

    The medial tibial stress syndrome score: Item generation for a new patient reported outcome measure. ... instrument that evaluates injury severity and treatment effects for medial tibial stress syndrome (MTSS) patients. ... from 32 Countries:.

  6. Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review.

    Science.gov (United States)

    Panni, Alfredo Schiavone; Ascione, Francesco; Rossini, Marco; Braile, Adriano; Corona, Katia; Vasso, Michele; Hirschmann, Michael T

    2017-12-15

    The aim of this systematic review is to analyze the effect of tibial rotational alignment after total knee arthroplasty (TKA) on clinical outcomes and assess the eventual cut-off values for tibial TKA rotation leading to poor outcomes. A detailed and systematic search from 1997 to 2017 of the Pubmed, Medline, Cochrane Reviews, and the Google Scholar databases was performed using the keyword terms "total knee arthroplasty", "total knee replacement", "tibial alignment", "tibial malalignement", "tibial rotation", "rotational error", "axis", "angle", "tibial malrotation", "clinical outcome", in several combinations. The modified Coleman scoring methodology (mCMS) was used. All the primary TKAs studies analyzing correlation between clinical results and tibial rotation were included. Five articles met the inclusion criteria. A total of 333 arthroplasties were included in this review; 139 had tibial component malalignment, while 194 were in control groups. The mean age of patients was 67.3 (SD 0.57) years. The mean average postoperative follow-up delay was 34.7 months (range 21-70). The mean mCMS score was 59.2 points indicating good methodological quality in the included studies. Functional outcomes were assessed through KSS, OKS, KOOS and VAS, negatively related to tibial internal rotation. Our review confirmed that excessive internal rotation of the tibial TKA component represents a significant risk factor for pain and inferior functional outcomes after TKA (> 10° of internal rotation demonstrated the common value), since external rotation does not affect the results. However, a universal precise cut-off value has not been found in the available literature and there remains a debate about CT rotation assessment and surgical intra-operative landmarks. III.

  7. Effect of tibial slope on the stability of the anterior cruciate ligament-deficient knee.

    Science.gov (United States)

    Voos, James E; Suero, Eduardo M; Citak, Musa; Petrigliano, Frank P; Bosscher, Marianne R F; Citak, Mustafa; Wickiewicz, Thomas L; Pearle, Andrew D

    2012-08-01

    We aimed to quantify the effect of changes in tibial slope on the magnitude of anterior tibial translation (ATT) in the anterior cruciate ligament (ACL)-deficient knee during the Lachman and mechanized pivot shift tests. We hypothesized that increased posterior tibial slope would increase the amount of ATT of an ACL-deficient knee, while leveling the slope of the tibial plateau would decrease the amount of ATT. Lachman and mechanized pivot shift tests were performed on hip-to-toe cadaveric specimens, and ATT of the lateral and the medial compartments was measured using navigation (n = 11). The ACL was then sectioned. Stability testing was repeated, and ATT was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5 or -5° of tibial slope variation after which stability testing was repeated (n = 10). Sectioning the ACL resulted in a significant increase in ATT in both the Lachman and mechanized pivot shift tests (P slope of the tibial plateau had no effect on ATT during the Lachman test (n.s.). During the mechanized pivot shift tests, a 5° increase in posterior slope resulted in a significant increase in ATT compared to the native knee (P slope reduced ATT to a level similar to that of the intact knee. Tibial slope changes did not affect the magnitude of translation during a Lachman test. However, large changes in tibial slope variation affected the magnitude of the pivot shift.

  8. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    Science.gov (United States)

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  9. Artroplastia total do joelho com o apoio tibial móvel: avaliação dos resultados a médio prazo Total knee arthroplasty with a mobile tibial bearing: medium-term follow-up results

    Directory of Open Access Journals (Sweden)

    Luiz Gabriel Betoni Guglielmetti

    2010-01-01

    Full Text Available OBJETIVO: Avaliações dos resultados a médio prazo da aplicação da prótese com apoio tibial móvel. MÉTODOS: Noventa e seis pacientes (107 joelhos foram submetidos a artroplastia total do joelho realizada com um modelo de prótese com mobilidade rotatória no componente tibial. Os pacientes foram avaliados após um seguimento médio de 52,7 meses - desvio padrão 21,94 (mínimo de 24 meses e máximo de 120 meses, através do protocolo de avaliação "Knee Society Clinical Rating System" (KSCRS, com uma média de 78,22 pontos. RESULTADOS: Entre as complicações transoperatórias e pós operatórias imediatas ocorreram uma deiscência de sutura, com cura espontânea, duas fraturas de patela, uma fratura do côndilo medial do fêmur, três paresias do nervo fibular lateral e uma distrofia nervosa simpático reflexa. As complicações tardias foram uma fratura da patela, uma fratura distal do fêmur, quatro solturas assépticas e quatro infecções profundas, que necessitaram de revisão. CONCLUSÃO: Excluindo-se os casos que necessitaram de uma revisão, por soltura séptica ou asséptica, os autores concluem serem bons os resultados clínicos e funcionais obtidos com a prótese com o apoio tibial móvel num seguimento a médio prazo.OBJECTIVE: Evaluation of mid-term follow up results of the application of a total knee replacement with a mobile tibial bearing design. METHODS: Ninety six patients (107 knees were submitted to total knee Arthroplasty, performed with a model of prosthesis with rotating mobility in the tibial component. The patients were evaluated after a mean follow-up of 52.7 months - standard deviation 21.94 (minimum 24 months and maximum 120 months through the Knee Society Clinical Rating System (KSCRS, with a mean outcome of 78.22 points. RESULTS: The complications that occurred immediately after or during the surgery included: one wound dehiscence with spontaneous healing, two patellar fractures, one fracture of the medial

  10. Ground reaction forces and bone parameters in females with tibial stress fracture.

    Science.gov (United States)

    Bennell, Kim; Crossley, Kay; Jayarajan, Jyotsna; Walton, Elizabeth; Warden, Stuart; Kiss, Z Stephen; Wrigley, Tim

    2004-03-01

    Tibial stress fracture is a common overuse running injury that results from the interplay of repetitive mechanical loading and bone strength. This research project aimed to determine whether female runners with a history of tibial stress fracture (TSF) differ in ground reaction force (GRF) parameters during running, regional bone density, and tibial bone geometry from those who have never sustained a stress fracture (NSF). Thirty-six female running athletes (13 TSF; 23 NSF) ranging in age from 18 to 44 yr were recruited for this cross-sectional study. The groups were well matched for demographic, training, and menstrual parameters. A force platform measured selected GRF parameters (peak and time to peak for vertical impact and active forces, and horizontal braking and propulsive forces) during overground running at 4.0 m.s.(-1). Lumbar spine, proximal femur, and distal tibial bone mineral density were assessed by dual energy x-ray absorptiometry. Tibial bone geometry (cross-sectional dimensions and areas, and second moments of area) was calculated from a computerized tomography scan at the junction of the middle and distal thirds. There were no significant differences between the groups for any of the GRF, bone density, or tibial bone geometric parameters (P > 0.05). Both TSF and NSF subjects had bone density levels that were average or above average compared with a young adult reference range. Factor analysis followed by discriminant function analysis did not find any combinations of variables that differentiated between TSF and NSF groups. These findings do not support a role for GRF, bone density, or tibial bone geometry in the development of tibial stress fractures, suggesting that other risk factors were more important in this cohort of female runners.

  11. End-to-side neurorrhaphy with and without perineurium

    Directory of Open Access Journals (Sweden)

    Fausto Viterbo

    Full Text Available OBJECTIVE: We compared end-to-side neurorraphy with and without the perineural sheath. METHOD: Twenty rats were used. The peroneal nerve was sectioned and the distal end was sutured to the lateral face of the tibial nerve. We removed the perineural sheath only on the right side, but not on the left side. The proximal end of the peroneal nerve was curved back approximately at a 100° angle and implanted into the adductor muscle. Six months later, the 14 surviving animals were submitted to electrophysiological tests, sacrificed, and the nerves and muscles were taken for histological exams. RESULTS: On the right side, the muscles that had positive response needed an average of 258.89 mV (±92.31 of electric stimulus and on the left side 298.34 mV (±139.32. The average weight of the tibial cranial muscles of the right side was 0.47 g (0.18 and for the left side 0.45 g (0.15. The distal end of the peroneal nerve showed averages of 310.29 (±191.34 nerve fibers on the right side and 287.71 (±183.60 on the left side. The tibial nerve above the neurorraphy showed averages of 939.46 (±223.51 nerve fibers on the right side and 959.46 (±327.48 on the left side. The tibial nerve below the neurorraphy showed averages of 935.17 (±298.65 nerve fibers on the right side and 755.31 (±323.26 on the left side. The average areas of the right tibial cranial muscles were 0.0162 m2 (±0.008, after 230 magnification, and 0.0152 m2 (0.0064 for the left tibial cranial muscles. The histological features of the tibial cranial muscles, taking normal as 100%, were 78.21 (±20.75 on the right side and 82.14 (±15.89 on the left side. The statistical analysis (Student's t test did not reveal any difference (p>0.05 among right and left sides for all variables. CONCLUSION: The authors concluded that the two neurorraphies (with and without perineurium did not show any difference regarding morphological and electrophysiological features studied.

  12. End-to-side neurorrhaphy with and without perineurium.

    Science.gov (United States)

    Viterbo, F; Teixeira, E; Hoshino, K; Padovani, C R

    1998-01-01

    We compared end-to-side neurorraphy with and without the perineural sheath. Twenty rats were used. The peroneal nerve was sectioned and the distal end was sutured to the lateral face of the tibial nerve. We removed the perineural sheath only on the right side, but not on the left side. The proximal end of the peroneal nerve was curved back approximately at a 100 degrees angle and implanted into the adductor muscle. Six months later, the 14 surviving animals were submitted to electrophysiological tests, sacrificed, and the nerves and muscles were taken for histological exams. On the right side, the muscles that had positive response needed an average of 258.89 mV (+/- 92.31) of electric stimulus and on the left side 298.34 mV (+/- 139.32). The average weight of the tibial cranial muscles of the right side was 0.47 g (0.18) and for the left side 0.45 g (0.15). The distal end of the peroneal nerve showed averages of 310.29 (+/- 191.34) nerve fibers on the right side and 287.71 (+/- 183.60) on the left side. The tibial nerve above the neurorraphy showed averages of 939.46 (+/- 223.51) nerve fibers on the right side and 959.46 (+/- 327.48) on the left side. The tibial nerve below the neurorraphy showed averages of 935.17 (+/- 298.65) nerve fibers on the right side and 755.31 (+/- 323.26) on the left side. The average areas of the right tibial cranial muscles were 0.0162 m2 (+/- 0.008), after 230 magnification, and 0.0152 m2 (0.0064) for the left tibial cranial muscles. The histological features of the tibial cranial muscles, taking normal as 100%, were 78.21 (+/- 20.75) on the right side and 82.14 (+/- 15.89) on the left side. The statistical analysis (Student's t test) did not reveal any difference (p > 0.05) among right and left sides for all variables. The authors concluded that the two neurorraphies (with and without perineurium) did not show any difference regarding morphological and electrophysiological features studied.

  13. Sex differences in the branching position of the nerve to the abductor digiti minimi muscle: an anatomical study of cadavers.

    Science.gov (United States)

    Mizuno, Daisuke; Naito, Munekazu; Hayashi, Shogo; Ohmichi, Yusuke; Ohmichi, Mika; Nakano, Takashi

    2015-01-01

    The nerve to the abductor digiti minimi muscle (ADMM nerve) is the first branch of the lateral plantar nerve or originates directly from the posterior tibial nerve. Damage to the ADMM nerve is a cause of heel pain and eventually results in ADMM atrophy. It is known that ADMM atrophy occurs more often in females than in males, and the reason remains unclear. This study aimed to explore sex differences in the branching pattern, position, and angle of the ADMM nerve. Forty-two cadavers (20 males, 22 females) were dissected at Aichi Medical University between 2011 and 2015. Cases of foot deformity or atrophy were excluded and 67 ft (30 male, 37 female) were examined to assess the branching pattern, position, and angle of the ADMM nerve. The branching positions of the ADMM nerve were superior to the malleolar-calcaneal axis (MCA) in 37 ft (55 %), on the MCA in 10 ft (15 %), and inferior to the MCA in 20 ft (30 %). There was no case among male feet in which the ADMM nerve branched inferior to the MCA, whereas this pattern was observed in 19 of 37 female feet (51 %). The branching position of the ADMM nerve was significantly closer to the MCA in female feet than in male feet. There were no significant sex differences in the branching pattern and angle of the ADMM nerve. The ADMM nerve sometimes branches off inferior to the MCA in females, but not in males. This difference may be the reason for the more frequent occurrence of ADMM atrophy in females than in males.

  14. Comparison of long-term results between osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis.

    Science.gov (United States)

    Charoenrook, Victor; Michael, Ralph; de la Paz, Maria Fideliz; Temprano, José; Barraquer, Rafael I

    2018-04-01

    To compare the anatomical and the functional results between osteo-odonto-keratoprosthesis (OOKP) and keratoprosthesis using tibial bone autograft (Tibial bone KPro). We reviewed the charts of 258 patients; 145 had OOKP whereas 113 had Tibial bone KPro implanted. Functional success was defined as best corrected visual acuity ≥0.05 on decimal scale and anatomical success as retention of the keratoprosthesis lamina. Kaplan-Meier survival curves were calculated for anatomical and functional survival as well as to estimate the probability of post-op complications. The anatomical survival for both KPro groups was not significantly different and was estimated as 67% for OOKP and 54% for Tibial bone KPro at 10 years after surgery. There was also no difference found after subdividing for primary diagnosis groups such as chemical injury, thermal burn, trachoma and all autoimmune cases combined. Estimated functional survival at 10 years post-surgery was 49% for OOKP and 25% for Tibial bone KPro, which was significantly different. The probability of patients with Tibial bone KPro developing one or more post-operative complications at 10 years after surgery (65%) was significantly higher than those with OOKP (40%). Mucous membrane necrosis and retroprosthetic membrane formation were more common in Tibial bone KPro than OOKP. Both types of autologous biological KPro, OOKP and Tibial bone KPro, had statistically similar rate of keratoprosthesis extrusion. Although functional success rate was significantly higher in OOKP, it may have been influenced by a better visual potential in the patients in this group. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Tibial valgus aperture osteotomy

    International Nuclear Information System (INIS)

    De los Rios G, Adolfo Leon; Saavedra Abadia, Adolfo Leon; Palacios, Julio

    2005-01-01

    This study is based on work carried out a The knee clinic at the arthroscopic surgery unit of the Institute of osteo-articular diseases, Imbanaco Medical Centre, The University Hospital of the Valle (Cali-Colombia) and The Fractures Clinic Ltd. (Palmira-Valle). This is a descriptive study, which demonstrates very positive outcomes for aperture osteotomy, without detracting from the importance of, and the progress made in uni-compartmental and total joint articular replacements of the knee. 10 patients were treated with a highs tibial open osteotomy between November 1988 and December 2002: 3 had post-traumatic deformities, without arthrosic alterations; 1 had pseudo-arthrosis caused by a failed corrective procedure; 1 had complex instability of the knee with osseous varus; 6 had a degenerative lesion of the medial meniscus with medial condral alterations. Follow-up was form 12 to 54 months. Treatment involved a tibial valgus aperture osteotomy and osteo-synthesis. Evaluation was carried out using the International Knee Documentation Committee (IKDC) scale, the For Special Surgery and The Knee Society Score

  16. Role of magnetic resonance imaging in entrapment and compressive neuropathy - what, where, and how to see the peripheral nerves on the musculoskeletal magnetic resonance image: part 1. Overview and lower extremity

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sungjun [Yonsei University, Department of Diagnostic Radiology, College of Medicine, Seoul (Korea); Hanyang University, Kuri Hospital, Department of Diagnostic Radiology, College of Medicine, Kuri City, Kyunggi-do (Korea); Choi, Jin-Young; Huh, Yong-Min; Song, Ho-Taek; Lee, Sung-Ah [Yonsei University, Department of Diagnostic Radiology, College of Medicine, Seoul (Korea); Kim, Seung Min [Yonsei University, Department of Neurology, College of Medicine, Seoul (Korea); Suh, Jin-Suck [Yonsei University, Department of Diagnostic Radiology, College of Medicine, Seoul (Korea); Yonsei University, Research Institute of Radiological Science, College of Medicine, Seoul (Korea)

    2007-01-15

    The diagnosis of nerve entrapment and compressive neuropathy has been traditionally based on the clinical and electrodiagnostic examinations. As a result of improvements in the magnetic resonance (MR) imaging modality, it plays not only a fundamental role in the detection of space-occupying lesions but also a compensatory role in clinically and electrodiagnostically inconclusive cases. Although ultrasound has undergone further development in the past decades and shows high resolution capabilities, it has inherent limitations due to its operator dependency. We review the general concepts that should be known to evaluate the entrapment and compressive neuropathy in MR imaging. We also review the course of normal peripheral nerves, as well as various clinical demonstrations and pathological features of compressed and entrapped nerves in the lower extremities on MR imaging, according to the nerves involved. The common sites of nerve entrapment of the lower extremity are as follows: sciatic nerve around the piriformis muscle; tibial nerve at the popliteal fossa and tarsal tunnel, common peroneal nerve around the fibular neck, and digital nerve near the metatarsal head. Although MR imaging can depict the peripheral nerves in the extremities effectively, radiologists should be familiar with nerve pathways, common sites of nerve compression, and common space-occupying lesions resulting in nerve compression in MR imaging. (orig.)

  17. Role of magnetic resonance imaging in entrapment and compressive neuropathy - what, where, and how to see the peripheral nerves on the musculoskeletal magnetic resonance image: part 1. Overview and lower extremity

    International Nuclear Information System (INIS)

    Kim, Sungjun; Choi, Jin-Young; Huh, Yong-Min; Song, Ho-Taek; Lee, Sung-Ah; Kim, Seung Min; Suh, Jin-Suck

    2007-01-01

    The diagnosis of nerve entrapment and compressive neuropathy has been traditionally based on the clinical and electrodiagnostic examinations. As a result of improvements in the magnetic resonance (MR) imaging modality, it plays not only a fundamental role in the detection of space-occupying lesions but also a compensatory role in clinically and electrodiagnostically inconclusive cases. Although ultrasound has undergone further development in the past decades and shows high resolution capabilities, it has inherent limitations due to its operator dependency. We review the general concepts that should be known to evaluate the entrapment and compressive neuropathy in MR imaging. We also review the course of normal peripheral nerves, as well as various clinical demonstrations and pathological features of compressed and entrapped nerves in the lower extremities on MR imaging, according to the nerves involved. The common sites of nerve entrapment of the lower extremity are as follows: sciatic nerve around the piriformis muscle; tibial nerve at the popliteal fossa and tarsal tunnel, common peroneal nerve around the fibular neck, and digital nerve near the metatarsal head. Although MR imaging can depict the peripheral nerves in the extremities effectively, radiologists should be familiar with nerve pathways, common sites of nerve compression, and common space-occupying lesions resulting in nerve compression in MR imaging. (orig.)

  18. [Magnetic resonance imaging of tibial periostitis].

    Science.gov (United States)

    Meyer, X; Boscagli, G; Tavernier, T; Aczel, F; Weber, F; Legros, R; Charlopain, P; Martin, J P

    1998-01-01

    Tibial periostitis frequently occurs in athletes. We present our experience with MRI in a series of 7 patients (11 legs) with this condition. The clinical presentation and scintigraphic scanning suggested the diagnosis. MRI exploration of 11 legs demonstrated a high band-like juxta-osseous signal enhancement of SE and IR T2 weighted sequences in 6 cases, a signal enhancement after i.v. contrast administration in 4. Tibial periostitis is a clinical diagnosis and MRI and scintigraphic findings can be used to assure the differential diagnosis in difficult cases with stress fracture. MRI can visualize juxta-osseous edematous and inflammatory reactions and an increased signal would appear to be characteristic when the band-like image is fixed to the periosteum.

  19. Distribution of elements in rat peripheral axons and nerve cell bodies determined by x-ray microprobe analysis

    Energy Technology Data Exchange (ETDEWEB)

    LoPachin, R.M. Jr.; Lowery, J.; Eichberg, J.; Kirkpatrick, J.B.; Cartwright, J. Jr.; Saubermann, A.J.

    1988-09-01

    X-ray microprobe analysis was used to determine concentrations (millimoles of element per kilogram dry weight) of Na, P, Cl, K, and Ca in cellular compartments of frozen, unfixed sections of rat sciatic and tibial nerves and dorsal root ganglion (DRG). Five compartments were examined in peripheral nerve (axoplasm, mitochondria, myelin, extraaxonal space, and Schwann cell cytoplasm), and four were analyzed in DRG nerve cell bodies (cytoplasm, mitochondria, nucleus, and nucleolus). Each morphological compartment exhibited characteristic concentrations of elements. The extraaxonal space contained high concentrations of Na, Cl, and Ca, whereas intraaxonal compartments exhibited lower concentrations of these elements but relatively high K contents. Nerve axoplasm and axonal mitochondria had similar elemental profiles, and both compartments displayed proximodistal gradients of decreasing levels of K, Cl, and, to some extent, Na. Myelin had a selectively high P concentration with low levels of other elements. The elemental concentrations of Schwann cell cytoplasm and DRG were similar, but both were different from that of axoplasm, in that K and Cl were markedly lower whereas P was higher. DRG cell nuclei contained substantially higher K levels than cytoplasm. The subcellular distribution of elements was clearly shown by color-coded images generated by computer-directed digital x-ray imaging. The results of this study demonstrate characteristic elemental distributions for each anatomical compartment, which doubtless reflect nerve cell structure and function.

  20. Coverage of extensive tibial bone exposure in burn patients with ...

    African Journals Online (AJOL)

    Covering tibial bone exposure from third degree burns to the lower limbs is a challenging task for the plastic surgeon. We present our experience of covering tibial exposure from burns in three different patients, where four limbs were involved and three muscular flaps were used in conjunction with one another; i.e. the ...

  1. Predicting Atmospheric Ionization and Excitation by Precipitating SEP and Solar Wind Protons Measured By MAVEN

    Science.gov (United States)

    Jolitz, Rebecca; Dong, Chuanfei; Lee, Christina; Lillis, Rob; Brain, David; Curry, Shannon; Halekas, Jasper; Bougher, Stephen W.; Jakosky, Bruce

    2017-10-01

    Precipitating energetic particles ionize and excite planetary atmospheres, increasing electron content and producing aurora. At Mars, the solar wind and solar energetic particles (SEPs) can precipitate directly into the atmosphere because solar wind protons can charge exchange to become neutral and pass the magnetosheath, and SEPs are sufficiently energetic to cross the magnetosheath unchanged. We will compare ionization and Lyman alpha emission rates for solar wind and SEP protons during nominal solar activity and a CME shock front impact event on May 16 2016. We will use the Atmospheric Scattering of Protons and Energetic Neutrals (ASPEN) model to compare excitation and ionization rates by SEPs and solar wind protons currently measured by the SWIA (Solar Wind Ion Analyzer) and SEP instruments aboard the MAVEN spacecraft. Results will help quantify how SEP and solar wind protons influence atmospheric energy deposition during solar minimum.

  2. Serum levels of TGF-β1 in patients of diabetic peripheral neuropathy and its correlation with nerve conduction velocity in type 2 diabetes mellitus.

    Science.gov (United States)

    Hussain, Gauhar; Rizvi, S Aijaz Abbas; Singhal, Sangeeta; Zubair, Mohammad; Ahmad, Jamal

    2016-01-01

    To correlate serum levels of TGF-β1 with motor and sensory nerve conduction velocities in patients of type 2 diabetes mellitus The study was conducted in diagnosed type 2 diabetes mellitus patients which were divided in patients with clinically detectable peripheral neuropathy of shorter duration (n=37) and longer duration (n=27). They were compared with patients without clinical neuropathy (n=22). Clinical diagnosis was based on neuropathy symptom score (NSS) and Neuropathy disability score (NDS) for signs. Blood samples were collected for baseline investigations and estimation of serum TGF-β1. Nerve conduction velocity was measured in both upper and lower limbs. Median, Ulnar, Common Peroneal and Posterior Tibial nerves were selected for motor nerve conduction study and Median and Sural nerves were selected for sensory nerve conduction study In patients of type 2 diabetes mellitus with clinically detectable and serum TGF-β1 showed positive correlation with nerve conduction velocities High level of TGF-β1 in serum of T2DM patients with neuropathy show possible contribution in development of neuropathy. Due to its independent association this cytokine might be used as biomarker for diabetic peripheral neuropathy. Copyright © 2015 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  3. [Maturation of cerebral somatosensory evoked potentials].

    Science.gov (United States)

    Cadilhac, J; Zhu, Y; Georgesco, M; Echenne, B; Rodiere, M

    1985-07-01

    Cerebral somatosensory evoked potentials (SEPs) were elicited by stimulation of the median nerve and/or posterior tibial nerve in 117 children of 1 day to 16 years old. A major negative wave (N) was consistently recorded from the parietal region of the scalp when the arm was stimulated. The peak latency, the onset latency, the rising time and the duration of H wave are closely correlated with age and body length. The latencies are shortest in the subjects of 1-3 years old. SEPs to lower extremity stimulation were inconstant in the infants before the age of one. The major positive wave (P) has a variable topographic distribution along the middle line, over the scalp. The latencies are also very variable in the different subjects of the same age as well as in the same subject with different locations of active electrode. Among the parameters studied as for N wave, only the rising time of P wave is significantly correlated with age. The latencies of P wave have the shortest value in the subjects of 1-3 years old. The comparison of SEPs to upper and to lower limb stimulations shows that there is no relationship between them in respect to their morphology and amplitude. The minimum value of the latencies of N and P waves was observed at the same age but the difference between the peak latencies of P and N waves in the same subject increases considerably after 2 years of age and reaches the adult value after 5 years of age. These resultats indicate that the maturation of the peripheral somatosensory pathways proceeds at a higher rate than that of the central somatosensory pathways, that the maturation of the somatosensory pathways of the upper limb precedes that of the lower limb, and that the rising time of N or P waves is a good index of cortical maturation. The clinical utility of these SEPs in pediatrics is discussed.

  4. Racial and ethnic health disparities: evidence of discrimination's effects across the SEP spectrum.

    Science.gov (United States)

    D'Anna, Laura Hoyt; Ponce, Ninez A; Siegel, Judith M

    2010-04-01

    Perceived discrimination is a psychosocial stressor that plays a role in explaining racial/ethnic disparities in self-reported physical and mental health. The purpose of this paper is: (1) to investigate the association between perceived discrimination in receiving healthcare and racial/ethnic disparities in self-rated health status, physical, and emotional functional limitations among a diverse sample of California adults; (2) to assess whether discrimination effects vary by racial/ethnic group and gender; and (3) to evaluate how the effects of discrimination on health are manifest across the socioeconomic position (SEP) spectrum. Data were drawn from the 2001 California Health Interview Survey adult file (n=55,428). The analytic approach employed multivariate linear and logistic regressions. Discrimination is qualitatively identified into two types: (1) discrimination due to race/ethnicity, language, or accent, and (2) other discrimination. Findings show that both types of discrimination negatively influenced self-rated health, and were associated with a two to three-fold odds of limitations in physical and emotional health. Further, these effects varied by racial/ethnic group and gender, and the effects were mixed. Most notably, for emotional health, racial/ethnic discrimination penalized Latinas more than non-Latina Whites, but for physical health, other discrimination was less detrimental to Latinas than it was to non-Latina Whites. At higher levels of SEP, the effects of racial/ethnic discrimination on self-rated health and other discriminations' effects on physical health were attenuated. Higher SEP may serve as an important mitigator, particularly when comparing the medium to the low SEP categories. It is also possible that SEP effects cannot be extracted from the relationships of interest in that SEP is an expression of social discrimination. In fact, negative health effects associated with discrimination are evident across the SEP spectrum. This study

  5. Radioactive Waste Decontamination Using Selentec Mag*SepSM Particles

    International Nuclear Information System (INIS)

    Walker, D.D.

    1998-01-01

    A sorbent containing crystalline silicotitanate (CST) tested for cesium removal from simulated Savannah River Site (SRS) soluble high activity waste showed rapid kinetics (1 h contact time) and high distribution coefficients (Kd 4000 mL/g of CST). The sorbent was prepared by Selective Environmental Technologies, Inc., (Selentec) as a MAG*SEP particle containing CST obtained from the Molecular Sieve Department of UOP, LLC, Results of preliminary tests suggest potential applications of the Selentec MAG*SEP particles to radioactive waste decontamination at SRS

  6. SEP-225289 serotonin and dopamine transporter occupancy: a PET study.

    Science.gov (United States)

    DeLorenzo, Christine; Lichenstein, Sarah; Schaefer, Karen; Dunn, Judith; Marshall, Randall; Organisak, Lisa; Kharidia, Jahnavi; Robertson, Brigitte; Mann, J John; Parsey, Ramin V

    2011-07-01

    SEP-225289 is a novel compound that, based on in vitro potencies for transporter function, potentially inhibits reuptake at dopamine, norepinephrine, and serotonin transporters. An open-label PET study was conducted during the development of SEP-225289 to investigate its dopamine and serotonin transporter occupancy. Different single doses of SEP-225289 were administered to healthy volunteers in 3 cohorts: 8 mg (n = 7), 12 mg (n = 5), and 16 mg (n = 7). PET was performed before and approximately 24 h after oral administration of SEP-225289, to assess occupancy at trough levels. Dopamine and serotonin transporter occupancies were estimated from PET using (11)C-N-(3-iodoprop-2E-enyl)-2β-carbomethoxy-3β-(4-methylphenyl)nortropane ((11)C-PE2I) and (11)C-N,N-dimethyl-2-(2-amino-4-cyanophenylthio)benzylamine ((11)C-DASB), respectively. Plasma concentration of SEP-225289 was assessed before ligand injection, and subjects were monitored for adverse events. Average dopamine and serotonin transporter occupancies increased with increasing doses of SEP-225289. Mean dopamine and serotonin transporter occupancies were 33% ± 11% and 2% ± 13%, respectively, for 8 mg; 44% ± 4% and 9% ± 10%, respectively, for 12 mg; and 49% ± 7% and 14% ± 15%, respectively, for 16 mg. On the basis of the relationship between occupancy and plasma concentration, dopamine transporter IC(50) (the plasma concentration of drug at 50% occupancy) was determined (4.5 ng/mL) and maximum dopamine transporter occupancy was extrapolated (85%); however, low serotonin transporter occupancy prevented similar serotonin transporter calculations. No serious adverse events were reported. At the doses evaluated, occupancy of the dopamine transporter was significantly higher than that of the serotonin transporter, despite similar in vitro potencies, confirming that, in addition to in vitro assays, PET occupancy studies can be instrumental to the drug development process by informing early decisions about

  7. ISO 50001 and SEP Faster and Cheaper - Exploring the Enterprise-Wide Approach

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingjing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Therkelsen, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sheaffer, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Scheihing, Paul [USDOE, Washington, DC (United States); Tamm, Yannick [Energetics, Inc. (United States)

    2017-06-01

    ISO 50001 and other management systems (e.g., ISO 9001 and ISO 14001) allow for implementation and certification at the enterprise level. The "Central Office" concept, which allows a small group of employees to manage and facilitate the organization’s energy management system (EnMS) at the enterprise level, was introduced within the ISO 50003 standard to provide guidance to ISO 50001 certification bodies. Four industrial companies have partnered with the United States Department of Energy to pilot the enterprise-wide ISO 50001/SEP concept under the Better Buildings Superior Energy Performance (SEP) Enterprise-wide Accelerator. Each organization developed a Central Office to host their EnMS while implementing ISO 50001/SEP at multiple physically separated sites. The four corporate partners tailored their Central Office implementation model to meet their own specific circumstances and needs. This paper reviews the commonalities, differences, and benefits of each of these enterprise-wide implementation models, including organizational structures, Central Office staff responsibilities, and key strategies. The cost savings and benefits of using the enterprise-wide approach were assessed, including the cost per site compared with that of a conventional, single-site ISO 50001/SEP implementation approach. This paper also discusses the drivers for the cost reductions realized through these enterprise-wide approaches. The four partner companies worked with 30 total sites. On average, these 30 sites improved energy performance by 5% annually over their SEP achievement periods, saved more than $600,000 annually in energy costs and reduced implementation cost for ISO 50001 and SEP by $19,000 and 0.8 Full Time Equivalent × years (FTE-yr) of staff time per site. The results can inform other organizations seeking to implement enterprise-wide ISO 50001/SEP, as well as energy efficiency organizations seeking to promote wider adoption of ISO 50001 implementation.

  8. Aneurisma verdadeiro bilateral de artéria tibial posterior True bilateral aneurysm of the posterior tibial artery

    Directory of Open Access Journals (Sweden)

    Silvio Romero de Barros Marques

    2006-03-01

    Full Text Available Neste artigo, faz-se o relato de um caso de aneurisma verdadeiro bilateral da artéria tibial posterior em paciente de 57 anos. Os aneurismas surgiram em épocas diferentes. Os aspectos clínicos, diagnósticos e terapêuticos deste caso são discutidos. Este relato é importante, pois os autores não têm conhecimento de caso semelhante na literatura consultada.This article reports a case of true bilateral aneurysm of the tibial posterior artery in a 57 year-old patient. The aneurysms occurred at different times. The clinical, diagnostic and therapeutic aspects of this case are discussed. This report is important because the authors did not find a similar description in the literature.

  9. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope.

    Science.gov (United States)

    Shen, Yi; Li, Xiaomiao; Fu, Xiaodong; Wang, Weili

    2015-11-01

    Posterior tibial slope that is created during proximal tibial resection in total knee arthroplasty has emerged as an important factor in the mechanics of the knee joint and the surgical outcome. But the ideal degree of posterior tibial slope for recovery of the knee joint function and preventions of complications remains controversial and should vary in different racial groups. The objective of this paper is to investigate the effects of posterior tibial slope on contact stresses in the tibial polyethylene component of total knee prostheses. Three-dimensional finite element analysis was used to calculate contact stresses in tibial polyethylene component of total knee prostheses subjected to a compressive load. The 3D finite element model of total knee prosthesis was constructed from the images produced by 3D scanning technology. Stresses in tibial polyethylene component were calculated with four different posterior tibial slopes (0°, 3°, 6° and 9°). The 3D finite element model of total knee prosthesis we presented was well validated. We found that the stress distribution in the polythene as evaluated by the distributions of the von Mises stress, the maximum principle stress, the minimum principle stress and the Cpress were more uniform with 3° and 6° posterior tibial slopes than with 0° and 9° posterior tibial slopes. Moreover, the peaks of the above stresses and trends of changes with increasing degree of knee flexion were more ideal with 3° and 6° posterior slopes. The results suggested that the tibial component inclination might be favourable to 7°-10° so far as the stress distribution is concerned. The range of the tibial component inclination also can decrease the wear of polyethylene. Chinese posterior tibial slope is bigger than in the West, and the current domestic use of prostheses is imported from the West, so their demands to tilt back bone cutting can lead to shorten the service life of prostheses; this experiment result is of important

  10. Effects of diabetic peripheral neuropathy on gait in vascular trans-tibial amputees.

    Science.gov (United States)

    Nakajima, Hiroshi; Yamamoto, Sumiko; Katsuhira, Junji

    2018-07-01

    Patients with diabetes often develop diabetic peripheral neuropathy, which is a distal symmetric polyneuropathy, so foot function on the non-amputated side is expected to affect gait in vascular trans-tibial amputees. However, there is little information on the kinematics and kinetics of gait or the effects of diabetic peripheral neuropathy in vascular trans-tibial amputees. This study aimed to clarify these effects, including the biomechanics of the ankle on the non-amputated side. Participants were 10 vascular trans-tibial amputees with diabetic peripheral neuropathy (group V) and 8 traumatic trans-tibial amputees (group T). Each subject's gait was analyzed at a self-selected speed using a three-dimensional motion analyzer and force plates. Ankle plantarflexion angle, heel elevation angle, and peak and impulse of anterior ground reaction force were smaller on the non-amputated side during pre-swing in group V than in group T. Center of gravity during pre-swing on the non-amputated side was lower in group V than in group T. Hip extension torque during loading response on the prosthetic side was greater in group V than in group T. These findings suggest that the biomechanical function of the ankle on the non-amputated side during pre-swing is poorer in vascular trans-tibial amputees with DPN than in traumatic trans-tibial amputees; the height of the center of gravity could not be maintained during this phase in vascular trans-tibial amputees with diabetic peripheral neuropathy. The hip joint on the prosthetic side compensated for this diminished function at the ankle during loading response. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Stress analysis of the tibial plateau according to the difference of blade path entry in opening wedge high tibial osteotomy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Woo; Xin, YuanZhu; Yang, Seok Jo [Chungnam National University, Daejeon (Korea, Republic of); Ji, Jong Hun; Panchal, Karnav; Kwon, Oh Soo [The Catholic University of Korea, Daejeon (Korea, Republic of)

    2015-03-15

    High tibial osteotomy (HTO) has been used to successfully treat patients with genu varus deformities that can improve mechanical function and condition in the knee joint. Clinical studies have reported that bow legs often occur with a concentrated load on the varus of the tibia. This study aimed to analyze and verify the clinical test data result by utilizing the three-dimensional (3D) static finite element method (FEM). The 3D model of lower extremities, which include the femur, tibia, meniscus, and knee articular cartilage, was created using the images from a computer tomography scan and magnetic resonance imaging. In this report, we compared changes in stress distribution and force reaction on the tibial plateau because of critical problems caused by unexpected changes in the tibial posterior-slope angle because of HTO. The results showed that the 5 .deg. wedge-angle virtual opening wedge HTO without and with the posterior-slope angle shows has a load concentration of approximately 60% and 45% in the medial region, respectively.

  12. Tibial stress fractures in racing Standardbreds: 13 cases (1989-1993)

    International Nuclear Information System (INIS)

    Ruggles, A.J.; Moore, R.M.; Bertone, A.L.; Schneider, R.K.; Bailey, M.Q.

    1996-01-01

    To determine clinical signs, radiographic and scintigraphic findings, and performance outcome of racing Standardbreds with tibial stress fractures. Retrospective case series. 13 racing Standardbreds with tibial stress fractures. Information concerning clinical signs, diagnostic evaluation, and recommendations was obtained by review of the medical records. Performance information before and after diagnosis of the fracture was collected from racing records, and follow-up information was obtained from the owners or trainers by use of a telephone questionnaire. Horses with tibial stress fractures were moderately lame, and diagnosis was made by nuclear scintigraphy and radiography. Fractures were more likely to occur in 2-year-old horses than in older horses. The fracture location was unique for Standardbreds; 11 of 13 developed stress fractures in the mid-diaphysis of the tibia, whereas fractures in Thoroughbreds are usually in the proximal caudal or caudolateral cortex. Fractures occurred in young horses that had raced or were in advanced race training. All horses were treated with rest alone, and 10 of 13 horses raced after injury. The horses that raced after injury were able to return to a level of performance that was equal to or better than the level raced before injury. 8 of 10 horses established a lifetime-best winning time after injury. Tibial stress fractures are a cause of lameness in young racing Standardbreds. Diagnosis is aided by nuclear scintigraphy. The prognosis for return to previous level of performance after a tibial stress fracture is good

  13. Predicting Ionization Rates from SEP and Solar Wind Proton Precipitation into the Martian Atmosphere

    Science.gov (United States)

    Jolitz, R.; Dong, C.; Lee, C. O.; Curry, S.; Lillis, R. J.; Brain, D.; Halekas, J. S.; Larson, D. E.; Bougher, S. W.; Jakosky, B. M.

    2017-12-01

    Precipitating energetic particles ionize planetary atmospheres and increase total electron content. At Mars, the solar wind and solar energetic particles (SEPs) can precipitate directly into the atmosphere because solar wind protons can charge exchange to become neutrals and pass through the magnetosheath, while SEPs are sufficiently energetic to cross the magnetosheath unchanged. In this study we will present predicted ionization rates and resulting electron densities produced by solar wind and SEP proton ionization during nominal solar activity and a CME shock front impact event on May 16 2016. We will use the Atmospheric Scattering of Protons and Energetic Neutrals (ASPEN) model to compare ionization by SEP and solar wind protons currently measured by the SWIA (Solar Wind Ion Analyzer) and SEP instruments aboard the MAVEN spacecraft. Results will help to quantify how the ionosphere responds to extreme solar events during solar minimum.

  14. Great SEP events and space weather: 2. Automatic determination of the solar energetic particle spectrum

    Science.gov (United States)

    Applbaum, David; Dorman, Lev; Pustil'Nik, Lev; Sternlieb, Abraham; Zagnetko, Alexander; Zukerman, Igor

    In Applbaum et al. (2010) it was described how the "SEP-Search" program works automat-ically, determining on the basis of on-line one-minute NM data the beginning of a great SEP event. The "SEP-Search" next uses one-minute data in order to check whether or not the observed increase reflects the beginning of a real great SEP event. If yes, the program "SEP-Research/Spectrum" automatically starts to work on line. We consider two variants: 1) quiet period (no change in cut-off rigidity), 2) disturbed period (characterized with possible changing of cut-off rigidity). We describe the method of determining the spectrum of SEP in the 1st vari-ant (for this we need data for at least two components with different coupling functions). For the 2nd variant we need data for at least three components with different coupling functions. We show that for these purposes one can use data of the total intensity and some different mul-tiplicities, but that it is better to use data from two or three NM with different cut-off rigidities. We describe in detail the algorithms of the program "SEP-Research/Spectrum." We show how this program worked on examples of some historical great SEP events. The work of NM on Mt. Hermon is supported by Israel (Tel Aviv University and ISA) -Italian (UNIRoma-Tre and IFSI-CNR) collaboration.

  15. Pseudoaneurysm of the Anterior Tibial Artery following Ankle Arthroscopy in a Soccer Player

    Directory of Open Access Journals (Sweden)

    Ichiro Tonogai

    2017-01-01

    Full Text Available Ankle arthroscopy carries a lower risk of vascular complications when standard anterolateral and anteromedial portals are used. However, the thickness of the fat pad at the anterior ankle affords little protection for the thin-walled anterior tibial artery, rendering it susceptible to indirect damage during procedures performed on the anterior ankle joint. To our knowledge, only 11 cases of pseudoaneurysm involving the anterior tibial artery after ankle arthroscopy have been described in the literature. Here we reported a rare case of a 19-year-old soccer player who presented with pseudoaneurysm of the anterior tibial artery following ankle arthroscopy using an ankle distraction method and underwent anastomosis for the anterior tibial artery injury. Excessive distraction of the ankle puts the neurovascular structures at greater risk for iatrogenic injury of the anterior tibial artery during ankle arthroscopy. Surgeons should look carefully for postoperative ankle swelling and pain after ankle arthroscopy.

  16. Long-term complications following tibial plateau levelling osteotomy in small dogs with tibial plateau angles > 30°.

    Science.gov (United States)

    Knight, Rebekah; Danielski, Alan

    2018-04-21

    Tibial plateau levelling osteotomy (TPLO) is commonly performed for surgical management of cranial cruciate ligament (CCL) disease. It has been suggested that small dogs may have steeper tibial plateau angles (TPAs) than large dogs, which has been associated with increased complication rates after TPLO. A retrospective study was performed to assess the rate and nature of long-term complications following TPLO in small dogs with TPAs>30°. Medical records were reviewed for dogs with TPAs>30° treated for CCL rupture by TPLO with a 2.0 mm plate over a five-year period. Radiographs were assessed to determine TPA, postoperative tibial tuberosity width and to identify any complication. Up-to-date medical records were obtained from the referring veterinary surgeon and any complications in the year after surgery were recorded. The effects of different variables on complication rate were assessed using logistic regression analysis. Minor complications were reported in 22.7 per cent of cases. This is similar to or lower than previously reported complication rates for osteotomy techniques in small dogs and dogs with steep TPAs. A smaller postoperative TPA was the only variable significantly associated with an increased complication rate. No major complications were identified. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Unstable gait due to spasticity of the rectus femoris: gait analysis and motor nerve block.

    Science.gov (United States)

    Gross, R; Leboeuf, F; Rémy-Néris, O; Perrouin-Verbe, B

    2012-12-01

    We present the case of a 54 year-old man presenting with a right Brown-Séquard plus syndrome (BSPS) after a traumatic cervical spinal cord injury. After being operated on with selective tibial neurotomy and triceps surae lengthening because of a right spastic equinus foot, he developed a gait disorder at high speed. The patient complained about an instability of the right knee. Observational gait analysis exhibited an oscillating, flexion/extension motion of the right knee during stance, which was confirmed by gait analysis. Dynamic electromyographic recordings exhibited a clonus of the right rectus femoris (RF) during stance. The spastic activity of the RF and the abnormal knee motion totally reversed after a motor nerve block of the RF, as well as after botulinum toxin type A injection into the RF. We emphasize that complex, spastic gait disorders can benefit from a comprehensive assessment including gait analysis and nerve blocks. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  18. Standing balance in people with trans-tibial amputation due to vascular causes: A literature review.

    Science.gov (United States)

    Seth, Mayank; Lamberg, Eric

    2017-08-01

    Balance is an important variable to consider during the rehabilitation process of individuals with trans-tibial amputation. Limited evidence exists on the balance abilities of people with trans-tibial amputation due to vascular causes. The purpose of this article is to review literature and determine if standing balance is diminished in people with trans-tibial amputation due to vascular causes. Literature review. Data were obtained from PubMed, Google Scholar, OandP.org , CINHAL, and Science Direct. Studies were selected only if they included standing balance assessment of people with unilateral trans-tibial amputation due to vascular causes. The review yielded seven articles that met the inclusion criteria. The general test methodology required participants to stand still on force platforms, with feet together, while center of pressure or postural sway was recorded. According to the findings of this review, individuals with trans-tibial amputees due to vascular causes have diminished balance abilities. Limited evidence suggests their balance might be further diminished as compared to individuals with trans-tibial amputation due to trauma. Although the evidence is limited, because of the underlying pathology and presence of comorbidities in individuals with trans-tibial amputation due to vascular causes, one cannot ignore these findings, as even a minor injury from a fall may develop into a non-healing ulcer and affect their health and well-being more severely than individuals with trans-tibial amputation due to trauma. Clinical relevance Individuals with trans-tibial amputation due to vascular causes have diminished balance abilities compared to healthy individuals and individuals with trans-tibial amputation due to trauma. This difference should be considered when designing and fabricating prostheses. Prosthetists and rehabilitation clinicians should consider designing amputation cause-specific rehabilitation interventions, focussing on balance and other

  19. Segmental transports for posttraumatic lower extremity bone defects: are femoral bone transports safer than tibial?

    Science.gov (United States)

    Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Ettinger, Max; Jagodzinski, Michael; Hankemeier, Stefan

    2011-02-01

    The long-term outcomes following femoral and tibial segment transports are not well documented. Purpose of the study is to compare the complication rates and life quality scores of femoral and tibial transports in order to find what are the complication rates of femoral and tibial monorail bone transports and if they are different? We retrospectively analyzed the medical records of 8 femoral and 14 tibial consecutive segment transports performed with the monorail technique between 2001 and 2008 in our institution. Mean follow-up was 5.1 ± 2.1 years with a minimum follow-up of 2 years. Aetiology of the defects was posttraumatic in all cases. Four femoral (50%) and nine tibial (64%) fractures were open. The Short Form-36 (SF-36) health survey was used to compare the life quality after femoral and tibial bone transports. The Mann-Whiney U test, Fisher exact test, and the Student's two tailed t-test were used for statistical analysis. P ≤ 0.05 was considered to be statistically significant. The tibial transport was associated with higher rates of severe complications and additional procedures (1.5 ± 0.9 vs. 3.4 ± 2.7, p = 0.048). Three patients of the tibial group were amputated because of recurrent infections and one developed a complete regenerate insufficiency that was treated with partial diaphyseal tibial replacement. Contrary to that none of patients of the femoral group developed a complete regenerate insufficiency or was amputated. Tibial bone transports have a higher rate of complete and incomplete regenerate insufficiency and can more often end in an amputation. The authors suggest systematic weekly controls of the CRP value and of the callus formation in patients with posttraumatic tibia bone transports. Further comparative studies comparing the results of bone transports with and without intramedullary implants are necessary.

  20. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

    Science.gov (United States)

    Han, Hyuk-Soo; Kang, Seung-Baik; Jo, Chris H; Kim, Sun-Hong; Lee, Jung-Ha

    2010-10-01

    Experimental and clinical studies on the accuracy of the intramedullary alignment method have produced different results, and few have addressed accuracy in the sagittal plane. Reported deviations are not only attributable to the alignment method but also to radiological errors. The purpose of this study was to evaluate the accuracy of the intramedullary alignment method in the sagittal plane using computed tomography (CT) and 3-dimensional imaging software. Thirty-one TKAs were performed using an intramedullary alignment method involving the insertion of a long 8-mm diameter rod into the medullary canal to the distal metaphysis of the tibia. All alignment instruments were set to achieve an ideal varus/valgus angle of 0° in the coronal plane and a tibial slope of 0° in the sagittal plane. The accuracy of the intramedullary alignment system was assessed by measuring the coronal tibial component angle and sagittal tibial slope angles, i.e., angles between the tibial anatomical axis and the tangent to the medial and lateral tibial plateau or the cut-surface. The mean coronal tibial component angle was 88.5° ± 1.2° and the mean tibial component slope in the sagittal plane was 1.6° ± 1.2° without anterior slope. Our intramedullary tibial alignment method, which involves passing an 8-mm diameter long rod through the tibial shaft isthmus, showed good accuracy (less than 3 degrees of variation and no anterior slope) in the sagittal plane in neutral or varus knees.

  1. Physeal growth arrest after tibial lengthening in achondroplasia: 23 children followed to skeletal maturity.

    Science.gov (United States)

    Song, Sang-Heon; Agashe, Mandar Vikas; Huh, Young-Jae; Hwang, Soon-Young; Song, Hae-Ryong

    2012-06-01

    Bilateral tibial lengthening has become one of the standard treatments for upper segment-lower segment disproportion and to improve quality of life in achondroplasia. We determined the effect of tibial lengthening on the tibial physis and compared tibial growth that occurred at the physis with that in non-operated patients with achondroplasia. We performed a retrospective analysis of serial radiographs until skeletal maturity in 23 achondroplasia patients who underwent bilateral tibial lengthening before skeletal maturity (lengthening group L) and 12 achondroplasia patients of similar height and age who did not undergo tibial lengthening (control group C). The mean amount of lengthening of tibia in group L was 9.2 cm (lengthening percentage: 60%) and the mean age at the time of lengthening was 8.2 years. The mean duration of follow-up was 9.8 years. Skeletal maturity (fusion of physis) occurred at 15.2 years in group L and at 16.0 years in group C. The actual length of tibia (without distraction) at skeletal maturity was 238 mm in group L and 277 mm in group C (p = 0.03). The mean growth rates showed a decrease in group L relative to group C from about 2 years after surgery. Physeal closure was most pronounced on the anterolateral proximal tibial physis, with relative preservation of the distal physis. Our findings indicate that physeal growth rate can be disturbed after tibial lengthening in achondroplasia, and a close watch should be kept for such an occurrence-especially when lengthening of more than 50% is attempted.

  2. The Tibial Slope in Patients With Achondroplasia: Its Characterization and Possible Role in Genu Recurvatum Development.

    Science.gov (United States)

    Brooks, Jaysson T; Bernholt, David L; Tran, Kevin V; Ain, Michael C

    2016-06-01

    Genu recurvatum, a posterior resting position of the knee, is a common lower extremity deformity in patients with achondroplasia and has been thought to be secondary to ligamentous laxity. To the best of our knowledge, the role of the tibial slope has not been investigated, and no studies describe the tibial slope in patients with achondroplasia. Our goals were to characterize the tibial slope in children and adults with achondroplasia, explore its possible role in the development of genu recurvatum, and compare the tibial slope in patients with achondroplasia to that in the general population. We reviewed 252 lateral knee radiographs of 130 patients with achondroplasia seen at our clinic from November 2007 through September 2013. Patients were excluded if they had previous lower extremity surgery or radiographs with extreme rotation. We analyzed patient demographics and, on all radiographs, the tibial slope. We then compared the mean tibial slope to norms in the literature. Tibial slopes >90 degrees had an anterior tibial slope and received a positive prefix. Statistical analysis included intraclass and interclass reliability, Pearson correlation coefficient, and the Student t tests (significance, Pachondroplasia than in the general population; however, this difference diminishes as patients' age. An anterior tibial slope may predispose to a more posterior resting knee position, also known as genu recurvatum. Level IV-retrospective case series.

  3. Chronic shin splints. Classification and management of medial tibial stress syndrome.

    Science.gov (United States)

    Detmer, D E

    1986-01-01

    A clinical classification and treatment programme has been developed for chronic medial tibial stress syndrome. Medial tibial stress syndrome has been reported to be either tibial stress fracture or microfracture, tibial periostitis, or distal deep posterior chronic compartment syndrome. Three chronic types exist and may coexist: Type I (tibial microfracture, bone stress reaction or cortical fracture); type II (periostalgia from chronic avulsion of the periosteum at the periosteal-fascial junction); and type III (chronic compartment syndrome syndrome). Type I disease is treated nonoperatively. Operations for resistant types II and III medial tibial stress syndrome were performed in 41 patients. Bilaterality was common (type II, 50% type III, 88%). Seven had coexistent type II/III; one had type I/II. Preoperative symptoms averaged 24 months in type II, 6 months in type III, and 33 months in types II/III. Mean age was 22 years (15 to 51). Resting compartment pressures were normal in type II (mean 12 mm Hg) and elevated in type III and type II/III (mean 23 mm Hg). Type II and type II/III patients received fasciotomy plus periosteal cauterisation. Type III patients had fasciotomy only. All procedures were performed on an outpatient basis using local anaesthesia. Follow up was complete and averaged 6 months (2 to 14 months). Improved performance was as follows: type II, 93%, type III, 100%; type II/III, 86%. Complete cures were as follows: type II, 78%; type III, 75%; and type II/III, 57%. This experience suggests that with precise diagnosis and treatment involving minimal risk and cost the athlete has a reasonable chance of return to full activity.

  4. Mediolateral Differences of Proteoglycans Distribution at the ACL Tibial Footprint: Experimental Study of 16 Cadaveric Knees

    Directory of Open Access Journals (Sweden)

    Joon Ho Wang

    2018-01-01

    Full Text Available This study aimed to identify the staining pattern of ACL attachment blended with cartilage of the medial tibial plateau at the tibial insertion and histologically characterize the tibial footprint. Sixteen fresh frozen cadaveric knees (mean age: 52.0±6.2 years were used for this study. The specimens were bisected in the coronal plane, in accordance with the fiber orientation of the ACL tibial attachment. Adjacent sections were then stained with hematoxylin and eosin (H&E to observe the morphology of the ACL insertion and with fast green and Safranin-O protocols to evaluate for collagen and proteoglycans (PG. The insertion area on the tibial footprint was divided into five zones in the medial to lateral direction, which was determined by division of the section from most prominent medial tibial spine to most lateral margin of ACL attachment. Then rectangular area with a vertical length that is twice the width of respective five zones was set. Stained areas of all images were quantified positively by using ImageJ software, and the value for staining area measured was defined in percentage by multiplying whole image area by 100. The mean proportion of Safranin-O staining is significantly greater nearer to the medial tibial spine (59% in zone 1, 32% in zone 2, 13% in zone 3, 13% in zone 4, and 4% in zone 5, P<0.001. The medial section of the tibial insertion area grew in size and increased in PG staining with more densely organized collagen arrangement with more fibrocartilage cells. The ACL tibial insertion showed a medially eccentric staining pattern by histological evaluation of the ACL attachment to cartilage. Our histological results of the eccentric biomaterial property in the medial tibial spine of ACL insertion area can be considered in making a more functional anatomic tibial tunnel placement.

  5. Pathomorphism of spiral tibial fractures in computed tomography imaging.

    Science.gov (United States)

    Guzik, Grzegorz

    2011-01-01

    Spiral fractures of the tibia are virtually homogeneous with regard to their pathomorphism. The differences that are seen concern the level of fracture of the fibula, and, to a lesser extent, the level of fracture of the tibia, the length of fracture cleft, and limb shortening following the trauma. While conventional radiographs provide sufficient information about the pathomorphism of fractures, computed tomography can be useful in demonstrating the spatial arrangement of bone fragments and topography of soft tissues surrounding the fracture site. Multiple cross-sectional computed tomography views of spiral fractures of the tibia show the details of the alignment of bone chips at the fracture site, axis of the tibial fracture cleft, and topography of soft tissues that are not visible on standard radiographs. A model of a spiral tibial fracture reveals periosteal stretching with increasing spiral and longitudinal displacement. The cleft in tibial fractures has a spiral shape and its line is invariable. Every spiral fracture of both crural bones results in extensive damage to the periosteum and may damage bellies of the long flexor muscle of toes, flexor hallucis longus as well as the posterior tibial muscle. Computed tomography images of spiral fractures of the tibia show details of damage that are otherwise invisible on standard radiographs. Moreover, CT images provide useful information about the spatial location of the bone chips as well as possible threats to soft tissues that surround the fracture site. Every spiral fracture of the tibia is associated with disruption of the periosteum. 1. Computed tomography images of spiral fractures of the tibia show details of damage otherwise invisible on standard radiographs, 2. The sharp end of the distal tibial chip can damage the tibialis posterior muscle, long flexor muscles of the toes and the flexor hallucis longus, 3. Every spiral fracture of the tibia is associated with disruption of the periosteum.

  6. Characterizing the Learning Effect in Response to Biofeedback Aimed at Reducing Tibial Acceleration during Running

    Directory of Open Access Journals (Sweden)

    Linda M. A. van Gelder

    2018-02-01

    Full Text Available Increased tibial acceleration has been found to be an important risk factor for tibial stress fractures. Interventions aimed at reducing this variable which found a beneficial effect include the use of biofeedback in gait retraining. However, no studies have focused on the time participants take to modify tibial acceleration, therefore we aimed to find the start of a learning plateau in this study. Six participants ran on a treadmill while multisensory feedback was given. A single-subject analysis was used to characterise the learning effects. All participants changed peak tibial acceleration within the first step of running in the feedback condition. Two participants further reduced tibial acceleration to reach a plateau within 120 steps. In four of the six participants a strong effect of the feedback was still present after a week. Further research is needed to optimise the use of biofeedback in reducing the prevalence of tibial stress fractures.

  7. The SEP "Robot": A Valid Virtual Reality Robotic Simulator for the Da Vinci Surgical System?

    NARCIS (Netherlands)

    van der Meijden, O. A. J.; Broeders, I. A. M. J.; Schijven, M. P.

    2010-01-01

    The aim of the study was to determine if the concept of face and construct validity may apply to the SurgicalSim Educational Platform (SEP) "robot" simulator. The SEP robot simulator is a virtual reality (VR) simulator aiming to train users on the Da Vinci Surgical System. To determine the SEP's

  8. Sequential avulsions of the tibial tubercle in an adolescent basketball player.

    Science.gov (United States)

    Huang, Ying Chieh; Chao, Ying-Hao; Lien, Fang-Chieh

    2010-05-01

    Tibial tubercle avulsion is an uncommon fracture in physically active adolescents. Sequential avulsion of tibial tubercles is extremely rare. We reported a healthy, active 15-year-old boy who suffered from left tibial tubercle avulsion fracture during a basketball game. He received open reduction and internal fixation with two smooth Kirschner wires and a cannulated screw, with every effort to reduce the plate injury. Long-leg splint was used for protection followed by programmed rehabilitation. He recovered uneventfully and returned to his previous level of activity soon. Another avulsion fracture happened at the right tibial tubercle 3.5 months later when he was playing the basketball. From the encouragement of previous successful treatment, we provided him open reduction and fixation with two small-caliber screws. He recovered uneventfully and returned to his previous level of activity soon. No genu recurvatum or other deformity was happening in our case at the end of 2-year follow-up. No evidence of Osgood-Schlatter disease or osteogenesis imperfecta was found. Sequential avulsion fractures of tibial tubercles are rare. Good functional recovery can often be obtained like our case if we treat it well. To a physically active adolescent, we should never overstate the risk of sequential avulsion of the other leg to postpone the return to an active, functional life.

  9. 186---07 Sep 2009 [Final version].indd

    African Journals Online (AJOL)

    2009-09-07

    Sep 7, 2009 ... It springs spontaneously from below via the multitude of theories associated with our .... because of its excessive relativism, which sees everything as relational. ..... more than materialism with a dash of moral sauce. Horizontal.

  10. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP)

    OpenAIRE

    Chandra Sekharam Naidu; Ch.Murali Krishna; Sankara Rao; Dharma Rao; Ashok Kumar

    2015-01-01

    INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures wer...

  11. Accuracy of clinical signs, SEP, and EEG in predicting outcome of hypoxic coma: a meta-analysis.

    Science.gov (United States)

    Lee, Y C; Phan, T G; Jolley, D J; Castley, H C; Ingram, D A; Reutens, D C

    2010-02-16

    Accurate prediction of neurologic outcome after hypoxic coma is important. Previous systematic reviews have not used summary statistics to summarize and formally compare the accuracy of different prognostic tests. We therefore used summary receiver operating characteristic curve (SROC) and cluster regression methods to compare motor and pupillary responses with sensory evoked potential (SEP) and EEG in predicting outcome after hypoxic coma. We searched PubMed, MEDLINE, and Embase (1966-2007) for reports in English, German, and French and identified 25 suitable studies. An SROC was constructed for each marker (SEP, EEG, M1 and M SEP was larger than those for M1, M SEP (AUC 0.891) and that for M1 (AUC 0.786) was small (0.105, 95% confidence interval 0.023-0.187), only reaching significance on day 1 after coma onset. The use of M SEP) is marginally better than M1 at predicting outcome after hypoxic coma. However, the superiority of SEP diminishes after day 1 and when M SEP is a better marker than clinical signs.

  12. The surgical anatomy of the infrapatellar branch of the saphenous nerve in relation to incisions for anteromedial knee surgery.

    Science.gov (United States)

    Kerver, A L A; Leliveld, M S; den Hartog, D; Verhofstad, M H J; Kleinrensink, G J

    2013-12-04

    Iatrogenic injury to the infrapatellar branch of the saphenous nerve is a common complication of surgical approaches to the anteromedial side of the knee. A detailed description of the relative anatomic course of the nerve is important to define clinical guidelines and minimize iatrogenic damage during anterior knee surgery. In twenty embalmed knees, the infrapatellar branch of the saphenous nerve was dissected. With use of a computer-assisted surgical anatomy mapping tool, safe and risk zones, as well as the location-dependent direction of the nerve, were calculated. The location of the infrapatellar branch of the saphenous nerve is highly variable, and no definite safe zone could be identified. The infrapatellar branch runs in neither a purely horizontal nor a vertical course. The course of the branch is location-dependent. Medially, it runs a nearly vertical course; medial to the patellar tendon, it has a -45° distal-lateral course; and on the patella and patellar tendon, it runs a close to horizontal-lateral course. Three low risk zones for iatrogenic nerve injury were identified: one is on the medial side of the knee, at the level of the tibial tuberosity, where a -45° oblique incision is least prone to damage the nerves, and two zones are located medial to the patellar apex (cranial and caudal), where close to horizontal incisions are least prone to damage the nerves. The infrapatellar branch of the saphenous nerve is at risk for iatrogenic damage in anteromedial knee surgery, especially when longitudinal incisions are made. There are three low risk zones for a safer anterior approach to the knee. The direction of the infrapatellar branch of the saphenous nerve is location-dependent. To minimize iatrogenic damage to the nerve, the direction of incisions should be parallel to the direction of the nerve when technically possible. These findings suggest that iatrogenic damage of the infrapatellar branch of the saphenous nerve can be minimized in anteromedial

  13. Simultaneous Modeling of Gradual SEP Events at the Earth and the Mars

    Science.gov (United States)

    Hu, J.; Li, G.

    2017-12-01

    Solar Energetic Particles (SEP) event is the number one space hazard for spacecraft instruments and astronauts' safety. Recent studies have shown that both longitudinal and radial extent of SEP events can be very significant. In this work, we use the improved Particle Acceleration and Transport in the Heliosphere (iPATH) model to simulate gradual SEP events that have impacts upon both the Earth and the Mars. We follow the propagation of a 2D CME-driven shock. Particles are accelerated at the shock via the diffusive shock acceleration (DSA) mechanism. Transport of the escaped particles to the Earth and the Mars is then followed using a backward stochastic differential equation method. Perpendicular diffusion is considered in both the DSA and the transport process. Model results such as time intensity profile and energetic particle spectrum at the two locations are compared to understand the spatial extent of an SEP event. Observational data at the Earth and the Mars are also studied to validate the model.

  14. Analysis on H spectral shape during the early 2012 SEPs with the PAMELA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Martucci, M., E-mail: matteo.martucci@roma2.infn.it [University of Rome “Tor Vergata”, Department of Physics, I-00133 Rome (Italy); INFN, Laboratori Nazionali di Frascati, Via Enrico Fermi 40, I-00044 Frascati (Italy); Boezio, M. [INFN, Sezione di Trieste, I-34149 Trieste (Italy); Bravar, U. [Space Science Center, University of New Hampshire (United States); Carbone, R. [INFN, Sezione di Trieste, I-34149 Trieste (Italy); Christian, E.R.; De Nolfo, G.A. [Heliospheric Physics Laboratory, NASA/Goddard Space Flight Center (United States); Mergè, M. [INFN, Sezione di Rome “Tor Vergata”, I-00133 Rome (Italy); University of Rome “Tor Vergata”, Department of Physics, I-00133 Rome (Italy); Mocchiutti, E. [INFN, Sezione di Trieste, I-34149 Trieste (Italy); Munini, R. [INFN, Sezione di Trieste, I-34149 Trieste (Italy); University of Trieste, Department of Physics, I-34147 Trieste (Italy); Ricci, M. [INFN, Laboratori Nazionali di Frascati, Via Enrico Fermi 40, I-00044 Frascati (Italy); Ryan, J.M. [Space Science Center, University of New Hampshire (United States); Sotgiu, A. [University of Rome “Tor Vergata”, Department of Physics, I-00133 Rome (Italy); Stochaj, S. [Electrical and Computer Engineering, New Mexico State University (United States); Thakur, N. [Heliospheric Physics Laboratory, NASA/Goddard Space Flight Center (United States); Adriani, O. [University of Florence, Department of Physics, I-50019 Sesto Fiorentino, Florence (Italy); INFN, Sezione di Florence, I-50019 Sesto Fiorentino, Florence (Italy); Barbarino, G.C. [University of Naples “Federico II”, Department of Physics, I-80126 Naples (Italy); INFN, Sezione di Naples, I-80126 Naples (Italy); and others

    2014-04-01

    The satellite-borne PAMELA experiment has been continuously collecting data since 2006. This apparatus is designed to study charged particles in the cosmic radiation. The combination of a permanent magnet, a silicon strip tracker and a silicon-tungsten imaging calorimeter, and the redundancy of instrumentation allow very precise studies on the physics of cosmic rays in a wide energy range and with high statistics. This makes PAMELA a very suitable instrument for Solar Energetic Particle (SEP) observations. Not only does it span the energy range between the ground-based neutron monitor data and the observations of SEPs from space, but PAMELA also carries out the first direct measurements of the composition for the highest energy SEP events, including those causing Ground Level Enhancements (GLEs). In particular, PAMELA has registered many SEP events during solar cycle 24, offering unique opportunities to address the question of high-energy SEP origin. A preliminary analysis on proton spectra behaviour during this event is presented in this work.

  15. Analysis on H spectral shape during the early 2012 SEPs with the PAMELA experiment

    International Nuclear Information System (INIS)

    Martucci, M.; Boezio, M.; Bravar, U.; Carbone, R.; Christian, E.R.; De Nolfo, G.A.; Mergè, M.; Mocchiutti, E.; Munini, R.; Ricci, M.; Ryan, J.M.; Sotgiu, A.; Stochaj, S.; Thakur, N.; Adriani, O.; Barbarino, G.C.

    2014-01-01

    The satellite-borne PAMELA experiment has been continuously collecting data since 2006. This apparatus is designed to study charged particles in the cosmic radiation. The combination of a permanent magnet, a silicon strip tracker and a silicon-tungsten imaging calorimeter, and the redundancy of instrumentation allow very precise studies on the physics of cosmic rays in a wide energy range and with high statistics. This makes PAMELA a very suitable instrument for Solar Energetic Particle (SEP) observations. Not only does it span the energy range between the ground-based neutron monitor data and the observations of SEPs from space, but PAMELA also carries out the first direct measurements of the composition for the highest energy SEP events, including those causing Ground Level Enhancements (GLEs). In particular, PAMELA has registered many SEP events during solar cycle 24, offering unique opportunities to address the question of high-energy SEP origin. A preliminary analysis on proton spectra behaviour during this event is presented in this work

  16. Implanted hair follicle stem cells form Schwann cells that support repair of severed peripheral nerves.

    Science.gov (United States)

    Amoh, Yasuyuki; Li, Lingna; Campillo, Raul; Kawahara, Katsumasa; Katsuoka, Kensei; Penman, Sheldon; Hoffman, Robert M

    2005-12-06

    The hair follicle bulge area is an abundant, easily accessible source of actively growing, pluripotent adult stem cells. Nestin, a protein marker for neural stem cells, also is expressed in follicle stem cells and their immediate, differentiated progeny. The fluorescent protein GFP, whose expression is driven by the nestin regulatory element in transgenic mice, served to mark the follicle cell fate. The pluripotent nestin-driven GFP stem cells are positive for the stem cell marker CD34 but negative for keratinocyte marker keratin 15, suggesting their relatively undifferentiated state. These cells can differentiate into neurons, glia, keratinocytes, smooth muscle cells, and melanocytes in vitro. In vivo studies show the nestin-driven GFP hair follicle stem cells can differentiate into blood vessels and neural tissue after transplantation to the subcutis of nude mice. Equivalent hair follicle stem cells derived from transgenic mice with beta-actin-driven GFP implanted into the gap region of a severed sciatic nerve greatly enhance the rate of nerve regeneration and the restoration of nerve function. The follicle cells transdifferentiate largely into Schwann cells, which are known to support neuron regrowth. Function of the rejoined sciatic nerve was measured by contraction of the gastrocnemius muscle upon electrical stimulation. After severing the tibial nerve and subsequent transplantation of hair follicle stem cells, walking print length and intermediate toe spread significantly recovered, indicating that the transplanted mice recovered the ability to walk normally. These results suggest that hair follicle stem cells provide an important, accessible, autologous source of adult stem cells for regenerative medicine.

  17. Influence of coronal holes on CMEs in causing SEP events

    International Nuclear Information System (INIS)

    Shen Chenglong; Yao Jia; Wang Yuming; Ye Pinzhong; Wang Shui; Zhao Xuepu

    2010-01-01

    The issue of the influence of coronal holes (CHs) on coronal mass ejections (CMEs) in causing solar energetic particle (SEP) events is revisited. It is a continuation and extension of our previous work, in which no evident effects of CHs on CMEs in generating SEPs were found by statistically investigating 56 CME events. This result is consistent with the conclusion obtained by Kahler in 2004. We extrapolate the coronal magnetic field, define CHs as the regions consisting of only open magnetic field lines and perform a similar analysis on this issue for 76 events in total by extending the study interval to the end of 2008. Three key parameters, CH proximity, CH area and CH relative position, are involved in the analysis. The new result confirms the previous conclusion that CHs did not show any evident effect on CMEs in causing SEP events. (research papers)

  18. Negative pressure wound therapy for Gustilo Anderson grade IIIb open tibial fractures

    Directory of Open Access Journals (Sweden)

    Chul Hyun Park

    2016-01-01

    Conclusion: Staged treatment using NPWT decreased the risks of infection and requirement of flap surgeries in Gustilo Anderson grade IIIb open tibial fractures. Therefore, staged treatment using NPWT could be a useful treatment option for Gustilo Anderson grade IIIb open tibial fractures.

  19. Ultrasound Guidance in Performing a Tendoscopic Surgery to Treat Posterior Tibial Tendinitis: A Useful Tool?

    Directory of Open Access Journals (Sweden)

    Akinobu Nishimura

    2016-01-01

    Full Text Available A 25-year-old man with a pronation-external rotation type of fracture was surgically treated using a fibular plate. Five years later, he underwent resection of bone hyperplasia because of the ankle pain and limitation of range of motion. Thereafter, the left ankle became intermittently painful, which persisted for about one year. He presented at the age of 43 with persistent ankle pain. Physical and image analysis findings indicated a diagnosis of posttraumatic posterior tibial tendinitis, which we surgically treated using tendoscopy. Endoscopic findings showed tenosynovitis and fibrillation on the tendon surface. We cleaned and removed the synovium surrounding the tendon and deepened the posterior tibial tendon groove to allow sufficient space for the posterior tibial tendon. Full weight-bearing ambulation was permitted one day after surgery and he returned to his occupation in the construction industry six weeks after surgery. The medial aspect of the ankle was free of pain and symptoms at a review two years after surgery. Although tendoscopic surgery for stage 1 posterior tibial tendon dysfunction has been reported, tendoscopic surgery to treat posttraumatic posterior tibial tendinitis has not. Our experience with this patient showed that tendoscopic surgery is useful not only for stage 1 posterior tibial dysfunction, but also for posttraumatic posterior tibial tendinitis.

  20. Properties of Coronal Shocks at the Origin of SEP events Observed by Only One Single Spacecraft

    Science.gov (United States)

    Lario, D.; Kwon, R.

    2017-12-01

    The simultaneous observation of solar energetic particle (SEP) events by multiple spacecraft distributed in the interplanetary medium depends not only on the spatial separation among the different spacecraft, but also on the properties of the particle sources and the characteristics of the SEP transport in interplanetary space. Among the SEP events observed by STEREO-A, STEREO-B and/or near-Earth spacecraft during solar cycle 24, we select SEP events observed by a single spacecraft (specifically, the SEP events observed only by near-Earth spacecraft on 2012 April 5, 2011 September 4, and 2013 August 17). We analyze whether the properties of the coronal shock associated with the origin of the events (as seen in extreme-ultraviolet and white-light coronal images) differ from those associated with SEP events observed by two or three spacecraft. For the selected events we find that the associated CMEs are, in general, narrower than those associated with SEP events observed by two or three spacecraft. The confined extension of the parent coronal shock and the absence of magnetic connection between distant spacecraft and the regions of the expanding coronal shock able to efficiently accelerate SEPs seem to be the conditions leading to intense SEP events observed only over narrow regions of interplanetary space by spacecraft magnetically connected to regions close to the parent eruption site. Weak and gradual intensity increases observed in extended regions of space might involve transport processes and/or later connections established with interplanetary shocks. Systematic analyses of a larger number of events are required before drawing firm conclusions.

  1. Medial tibial pain. A prospective study of its cause among military recruits.

    Science.gov (United States)

    Milgrom, C; Giladi, M; Stein, M; Kashtan, H; Margulies, J; Chisin, R; Steinberg, R; Swissa, A; Aharonson, Z

    1986-12-01

    In a prospective study of 295 infantry recruits during 14 weeks of basic training, 41% had medial tibial pain. Routine scintigraphic evaluation in cases of medial tibial bone pain showed that 63% had abnormalities. A stress fracture was found in 46%. Only two patients had periostitis. None had ischemic medial compartment syndrome. Physical examination could not differentiate between cases with medial tibial bone pain secondary to stress fractures and those with scintigraphically normal tibias. When both pain and swelling were localized in the middle one-third of the tibia, the lesion most likely proved to be a stress fracture.

  2. [Mobility of a polyethylene tibial insert in a mobile total knee prosthesis].

    Science.gov (United States)

    Castel, E; Roger, B; Camproux, A; Saillant, G

    1999-03-01

    We have studied the mobility of a mobile tibial implant in total knee arthroplasty (TKA) by a radiographical evaluation. We analyzed mobility of the polyethylene tibial insert of 15 "G2S" TKA implanted for one year or more. We established a dynamic radiographical evaluation. We used 3 weight-bearing radiographs: AP in extension and two lateral (one in extension and one at 90 degrees of flexion), two AP with femoral internal and external rotation, 2 strict lateral X-rays in neutral rotation in antero-posterior replacement with a 25 kilograms strength Telos, and 2 AP in varus and valgus with Telos. Wilcoxon's test and Fisher's exact test were used for statistical evaluation. Our study demonstrated preservation of the polyethylene mobility in tibial TKA implant in all movements: in rotation, in antero-posterior translation with Telos, and even in antero-posterior translation during physiological condition with flexion-extension weight-bearing radiographs. Statistical tests were very significant. We noticed that flexion induced anterior translation of tibial polyethylene when PCL was preserved. This study answered to our question whether mobility of TKA tibial implant persists after implantation. This mobility should reduce loosening forces to the tibia and stress in the polyethylene component. Now we have to determine the amplitude of mobility required to reach this objective.

  3. SeP, ApoER2 and megalin as necessary factors to maintain Se homeostasis in mammals.

    Science.gov (United States)

    Krol, Magdalena Beata; Gromadzinska, Jolanta; Wasowicz, Wojciech

    2012-10-01

    Selenoprotein P (SeP) is an extracellular protein containing ten selenium atoms in the form of selenocysteine, secreted mainly from the liver. About 60% of the whole plasma selenium level is present in SeP, which makes it a useful biomarker of selenium nutritional status. The main functions of SeP are transport and storage of selenium in plasma. It is especially an important protein for the brain, testes and kidneys where the supplementation of the proper amount of Se ensures the synthesis of selenoenzymes with antioxidant properties.Recently, it has been found that SeP uptake in kidneys, testes and brain depends on the apolipoprotein receptor 2 (ApoER2) and lipoprotein megalin receptor (Lrp2). Megalin receptor represents a physiological SeP receptor in kidneys, mediating the re-uptake of secreted SeP from the primary urine. The absence of a functional megalin receptor causes a significant reduction of plasma selenium and the SeP levels as a result of Se excretion. ApoER2 is a SeP receptor in the brain and testes which uptakes Se from the extracellular fluid. Deletion of ApoER2 in mice leads to a lowered selenium level in the brain and testes, neurological dysfunction, production of abnormal spermatozoa, infertility and even death when the subjects are fed a low-selenium diet. Copyright © 2012 Elsevier GmbH. All rights reserved.

  4. A COMPARISON OF ELEMENTAL ABUNDANCE RATIOS IN SEP EVENTS IN FAST AND SLOW SOLAR WIND REGIONS

    International Nuclear Information System (INIS)

    Kahler, S. W.; Tylka, A. J.; Reames, D. V.

    2009-01-01

    The solar energetic (E > 1 MeV nucleon -1 ) particles (SEPs) observed in gradual events at 1 AU are assumed to be accelerated by coronal/interplanetary shocks from ambient thermal or suprathermal seed particles. If so, then the elemental abundances of SEPs produced in different solar wind (SW) stream types (transient, fast, and slow) might be systematically distinguished from each other. We look for these differences in SEP energy spectra and in elemental abundance ratios (including Mg/Ne and Fe/C, which compare low/high first ionization potential elements), in a large number of SEP time intervals over the past solar cycle. The SW regions are characterized by the three-component stream classification of Richardson et al. Our survey shows no significant compositional or energy spectral differences in the 5-10 MeV nucleon -1 range for SEP events of different SW stream types. This result extends the earlier finding that SEP events are observed frequently in fast SW streams, although their higher Alfven and SW flow speeds should constrain SEP production by coronal mass ejection-driven shocks in those regions. We discuss the implications of our results for shock seed populations and cross-field propagation.

  5. Impact of the "faster better cheaper" requirements for satellites components/subsystems on SEP organisation and processes.

    Science.gov (United States)

    Pages, X.

    2000-03-01

    In the early 90's, SEP environment in the satellites business quickly evolved from agencies funded programs (ESA, CNES, government) to a situation in which SEP has numerous private customers and where agencies behave as private companies i.e. opening world-wide competition, requesting high involvement of SEP in non recurring funding. SEP quickly reacted to face this challenge by improving not only their products but also the way these products are developed and produced. A new organization of SEP/DPES unit (around 200 people) was set up end 1994, with project oriented guidelines such as streamlining the hierarchical levels in order to increase personals implication and motivation, favoring flexible project organizations to the previous somewhat rigid matrix organization, enforcing commercial/marketing structure to the new customers. Highly motivated slim teams were constituted around each project, picking up expert partners inside SEP/DPES departments. Project partners proved to plead in an efficient manner with their own management on the behalf of the projects they were implied in. Eventually, this organization helped, of course with other progress actions, to a global performance improvement of SEP/DPES. Improved development processes were put into practice in 1995 among which design to cost, carefully decided internal preliminary studies, long term agreements with preferred subcontractors. SEP/DPES ISO.9001 certification (mid-1998) which gives evidence of the satisfactory status of SEP/DPES PA system already helps to avoid to costly comply with numerous project tailored P.A. requirements. New products were developed/qualified since the mid-90's, on SEP funding (at least partial, sometimes total), following the here before described processes and organization. Among SEP/DPES newly developed products, three examples are more thoroughly discussed. In the field of electrical propulsion where SEP/DPES has gained expertise in since the 60's, new developments started

  6. Tibial hyperostosis: A diagnostic approach

    International Nuclear Information System (INIS)

    Touraine, Sébastien; Parlier-Cuau, Caroline; Bousson, Valérie; Sverzut, Jean-Michel; Genah, Idan

    2013-01-01

    Tibial hyperostosis may be encountered in musculoskeletal imaging, incidentally or during the investigation of a leg pain. Hyperostosis involves the exuberant production of osseous tissue and results in cortical, periosteal and/or endosteal thickening of the bone. As a long bone with thick cortices, the tibia has a significant probability of being affected by ubiquitous bone diseases. As a tubular long bone, the tibia is likely to be involved in extensive infectious conditions such as osteomyelitis. As a bone of the lower limb, the tibia undergoes high stresses and may be affected by decrease in bone strength or repetitive submaximal stress. The tibia is also particularly involved in some bone sclerosing dysplasias and Paget's disease. In this work, we aim at highlighting the main conditions leading to tibial hyperostosis and try to provide key elements to narrow down the several diagnostic possibilities. Osteoid osteomas, fatigue or insufficiency fractures, infectious conditions, vascular lesions, sclerosing bone dysplasias and Paget's disease represent the main challenging diagnoses to discuss

  7. Tibial hyperostosis: A diagnostic approach

    Energy Technology Data Exchange (ETDEWEB)

    Touraine, Sébastien, E-mail: sebastien.touraine@lrb.aphp.fr [Radiologie ostéo-articulaire, Hôpital Lariboisière, 2 rue Ambroise Paré, 75475 Paris Cedex 10 (France); Parlier-Cuau, Caroline, E-mail: caroline.parlier@lrb.aphp.fr [Radiologie ostéo-articulaire, Hôpital Lariboisière, 2 rue Ambroise Paré, 75475 Paris Cedex 10 (France); Bousson, Valérie, E-mail: valerie.bousson@lrb.aphp.fr [Radiologie ostéo-articulaire, Hôpital Lariboisière, 2 rue Ambroise Paré, 75475 Paris Cedex 10 (France); Sverzut, Jean-Michel, E-mail: jmsverzut21@hotmail.com [Radiologie ostéo-articulaire, Hôpital Lariboisière, 2 rue Ambroise Paré, 75475 Paris Cedex 10 (France); Centre d’imagerie du centre cardiologique du Nord, 32-36 rue des Moulins Gémeaux, 93200 Saint-Denis (France); Genah, Idan, E-mail: idan.genah@lrb.aphp.fr [Radiologie ostéo-articulaire, Hôpital Lariboisière, 2 rue Ambroise Paré, 75475 Paris Cedex 10 (France); and others

    2013-12-01

    Tibial hyperostosis may be encountered in musculoskeletal imaging, incidentally or during the investigation of a leg pain. Hyperostosis involves the exuberant production of osseous tissue and results in cortical, periosteal and/or endosteal thickening of the bone. As a long bone with thick cortices, the tibia has a significant probability of being affected by ubiquitous bone diseases. As a tubular long bone, the tibia is likely to be involved in extensive infectious conditions such as osteomyelitis. As a bone of the lower limb, the tibia undergoes high stresses and may be affected by decrease in bone strength or repetitive submaximal stress. The tibia is also particularly involved in some bone sclerosing dysplasias and Paget's disease. In this work, we aim at highlighting the main conditions leading to tibial hyperostosis and try to provide key elements to narrow down the several diagnostic possibilities. Osteoid osteomas, fatigue or insufficiency fractures, infectious conditions, vascular lesions, sclerosing bone dysplasias and Paget's disease represent the main challenging diagnoses to discuss.

  8. Management of tibial fractures using a circular external fixator in two calves.

    Science.gov (United States)

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  9. Human tibial torsion - Morphometric assessment and clinical relevance

    Directory of Open Access Journals (Sweden)

    Swati Gandhi

    2014-02-01

    Full Text Available Background: Tibial torsion is an important anatomical parameter in clinical practice and displays variability among individuals. These variations are extremely significant in view of alignment guides such as those related to rotational landmarks of tibia in total knee arthroplasty. Further, precise knowledge and information pertaining to angle of tibial torsion also helps in correction of traumatic malunion or congenital maltorsion of tibia. Methods: The present study was carried out to determine the angle of tibial torsion in 100 adult dry tibia bones in the Department of Anatomy, Government Medical College, Amritsar. The study group comprised 50 males and 50 females with equal number of right- and left-sided bones. The measurements were meticulously recorded and the data were subjected to statistical analysis. The results were analyzed and discussed in the light of existing literature. Results: On the right side, it was found to be 29.84° ± 4.86°° (range = 22.00° -38.00° in males and 28.92° ± 5.10°° (range = 15.00°-38.00° in females. On the left side, it was found to be 28.00° ± 4.94°° (range = 20.00°-40.00°° in males and 28.12° ± 4.28°° (range = 20.00°-37.00°° in females. Conclusion: The present study is an endeavor to provide baseline data with reference to the angle of tibial torsion in the Indian population. The results of the study assume special importance in view of the technical advancements in reconstructive surgical procedures in orthopedic practice.

  10. Treatment of segmental tibial fractures with supercutaneous plating.

    Science.gov (United States)

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  11. Terminal nerve: cranial nerve zero

    Directory of Open Access Journals (Sweden)

    Jorge Eduardo Duque Parra

    2006-12-01

    Full Text Available It has been stated, in different types of texts, that there are only twelve pairs of cranial nerves. Such texts exclude the existence of another cranial pair, the terminal nerve or even cranial zero. This paper considers the mentioned nerve like a cranial pair, specifying both its connections and its functional role in the migration of liberating neurons of the gonadotropic hormone (Gn RH. In this paper is also stated the hypothesis of the phylogenetic existence of a cerebral sector and a common nerve that integrates the terminal nerve with the olfactory nerves and the vomeronasals nerves which seem to carry out the odors detection function as well as in the food search, pheromone detection and nasal vascular regulation.

  12. Tibial rotational osteotomy for idiopathic torsion. A comparison of the proximal and distal osteotomy levels.

    Science.gov (United States)

    Krengel, W F; Staheli, L T

    1992-10-01

    A retrospective analysis was done of 52 rotational tibial osteotomies (RTOs) performed on 35 patients with severe idiopathic tibial torsion. Thirty-nine osteotomies were performed at the proximal or midtibial level. Thirteen were performed at the distal tibial level with a technique previously described by one of the authors. Serious complications occurred in five (13%) of the proximal and in none of the distal RTOs. For severe and persisting idiopathic tibial torsion, the authors recommend correction by RTO at the distal level. Proximal level osteotomy is indicated only when a varus or valgus deformity required concurrent correction.

  13. Complications of Open Tibial Fracture Management: Risk Factors and Treatment

    OpenAIRE

    Lua, JYC; Tan, VH; Sivasubramanian, H; Kwek, EBK

    2017-01-01

    Open tibial fractures result in high rates of complications. This study aims to elucidate the risk factors causing these complications, and suggest antimicrobial regimens based on the organisms grown in post-operative infections. Over a period of five years, 173 patients had sustained open tibial fractures and undergone operative treatment at a single institution. All surgical data was gathered retrospectively through online medical records. Thirty-one patients (17.9%) had sustained post-oper...

  14. The transverse ligament as a landmark for tibial sagittal insertions of the anterior cruciate ligament: a cadaveric study.

    Science.gov (United States)

    Kongcharoensombat, Wirat; Ochi, Mitsuo; Abouheif, Mohamed; Adachi, Nobuo; Ohkawa, Shingo; Kamei, Goki; Okuhara, Atushi; Shibuya, Hoyatoshi; Niimoto, Takuya; Nakasa, Tomoyuki; Nakamae, Atsuo; Deie, Masataka

    2011-10-01

    The purpose of this study was to determine the relation between the position of the transverse ligament, the anterior edge of the anterior cruciate ligament (ACL) tibial footprint, and the center of the ACL tibial insertion. We used arthroscopy for localization of the anatomic landmarks, followed by insertions of guide pins under direct visualization, and then the position of these guide pins was checked on plain lateral radiographs. The transverse ligament and the anterior aspect of the ACL tibial footprint were identified by arthroscopy in 20 unpaired cadaveric knees (10 left and 10 right). Guide pins were inserted with tibial ACL adapter drill guides under direct observation at the transverse ligament, the anterior aspect of the tibial footprint, and the center of tibial insertion of the ACL. Then, plain lateral radiographs of specimens were taken. The Amis and Jakob line was used to define the attachment of the ACL tibial insertion and the transverse ligament. A sagittal percentage of the location of the insertion point was determined and calculated from the anterior margin of the tibia in the anteroposterior direction. The transverse ligament averaged 21.20% ± 4.1%, the anterior edge of the ACL tibial insertion averaged 21.60% ± 4.0%, and the center of the ACL tibial insertion averaged 40.30% ± 4.8%. There were similar percent variations between the transverse ligament and the anterior edge of the ACL tibial insertion, with no significant difference between them (P = .38). Intraobserver and interobserver reliability was high, with small standard errors of measurement. This study shows that the transverse ligament coincides with the anterior edge of the ACL tibial footprint in the sagittal plane. The transverse ligament can be considered as a new landmark for tibial tunnel positioning during anatomic ACL reconstruction. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Long-lasting solar energetic electron injection during the 26 Dec 2013 widespread SEP event

    Science.gov (United States)

    Dresing, N.; Klassen, A.; Temmer, M.; Gomez-Herrero, R.; Heber, B.; Veronig, A.

    2017-12-01

    The solar energetic particle (SEP) event on 26 Dec 2013 was detected all around the Sun by the two STEREO spacecraft and close-to-Earth observers. While the two STEREOs were separated by 59 degrees and situated at the front side of the associated large coronal event, it was a backside-event for Earth. Nevertheless, significant and long-lasting solar energetic electron anisotropies together with long rise times were observed at all three viewpoints, pointing to an extended electron injection. Although the CME-driven shock appears to account for the SEP event at a first glance a more detailed view reveals a more complex scenario: A CME-CME interaction takes place during the very early phase of the SEP event. Furthermore, four hours after the onset of the event, a second component is measured at all three viewpoints on top of the first SEP increase, mainly consisting of high energy particles. We find that the CME-driven shock alone can hardly account for the observed SEP event in total but a trapping scenario together with ongoing particle acceleration is more likely.

  16. Selenoprotein S/SEPS1 modifies endoplasmic reticulum stress in Z variant alpha1-antitrypsin deficiency.

    LENUS (Irish Health Repository)

    Kelly, Emer

    2009-06-19

    Z alpha(1)-antitrypsin (ZAAT) deficiency is a disease associated with emphysematous lung disease and also with liver disease. The liver disease of AAT deficiency is associated with endoplasmic reticulum (ER) stress. SEPS1 is a selenoprotein that, through a chaperone activity, decreases ER stress. To determine the effect of SEPS1 on ER stress in ZAAT deficiency, we measured activity of the grp78 promoter and levels of active ATF6 as markers of the unfolded protein response in HepG2 cells transfected with the mutant form of AAT, a ZAAT transgene. We evaluated levels of NFkappaB activity as a marker of the ER overload response. To determine the effect of selenium supplementation on the function of SEPS1, we investigated glutathione peroxidase activity, grp78 promoter activity, and NFkappaB activity in the presence or absence of selenium. SEPS1 reduced levels of active ATF6. Overexpression of SEPS1 also inhibited grp78 promoter and NFkappaB activity, and this effect was enhanced in the presence of selenium supplementation. This finding demonstrates a role for SEPS1 in ZAAT deficiency and suggests a possible therapeutic potential for selenium supplementation.

  17. Effect of cranial cruciate ligament deficiency, tibial plateau leveling osteotomy, and tibial tuberosity advancement on contact mechanics and alignment of the stifle in flexion.

    Science.gov (United States)

    Kim, Stanley E; Pozzi, Antonio; Banks, Scott A; Conrad, Bryan P; Lewis, Daniel D

    2010-04-01

    To assess contact mechanics and 3-dimensional (3-D) joint alignment in cranial cruciate ligament (CCL)-deficient stifles before and after tibial plateau leveling osteotomy (TPLO) and tibial tuberosity advancement (TTA) with the stifle in 90 degrees of flexion. In vitro biomechanical study. Cadaveric pelvic limb pairs (n=8) from dogs weighing 28-35 kg. Contralateral limbs were assigned to receive TPLO or TTA. Digital pressure sensors were used to measure femorotibial contact area, peak and mean contact pressure, and peak pressure location with the limb under a load of 30% body weight and stifle flexion angle of 90 degrees . 3-D poses were obtained using a Microscribe digitizer. Specimens were tested under normal, CCL deficient, and treatment conditions. Significant disturbances in alignment were not observed after CCL transection, although medial contact area was 10% smaller than normal (P=.003). There were no significant differences in contact mechanics or alignment between normal and TTA conditions; TPLO induced 6 degrees varus angulation (PCranial tibial subluxation is nominal in CCL-deficient stifles loaded in flexion. Stifle alignment and contact mechanics are not altered by TTA, whereas TPLO causes mild varus and a subsequent increase in medial compartment loading. Cranial tibial subluxation of CCL-deficient stifles may not occur during postures that load the stifle in flexion. The significance of minor changes in loading patterns after TPLO is unknown.

  18. Prediction of Tibial Rotation Pathologies Using Particle Swarm Optimization and K-Means Algorithms.

    Science.gov (United States)

    Sari, Murat; Tuna, Can; Akogul, Serkan

    2018-03-28

    The aim of this article is to investigate pathological subjects from a population through different physical factors. To achieve this, particle swarm optimization (PSO) and K-means (KM) clustering algorithms have been combined (PSO-KM). Datasets provided by the literature were divided into three clusters based on age and weight parameters and each one of right tibial external rotation (RTER), right tibial internal rotation (RTIR), left tibial external rotation (LTER), and left tibial internal rotation (LTIR) values were divided into three types as Type 1, Type 2 and Type 3 (Type 2 is non-pathological (normal) and the other two types are pathological (abnormal)), respectively. The rotation values of every subject in any cluster were noted. Then the algorithm was run and the produced values were also considered. The values of the produced algorithm, the PSO-KM, have been compared with the real values. The hybrid PSO-KM algorithm has been very successful on the optimal clustering of the tibial rotation types through the physical criteria. In this investigation, Type 2 (pathological subjects) is of especially high predictability and the PSO-KM algorithm has been very successful as an operation system for clustering and optimizing the tibial motion data assessments. These research findings are expected to be very useful for health providers, such as physiotherapists, orthopedists, and so on, in which this consequence may help clinicians to appropriately designing proper treatment schedules for patients.

  19. Expected long-term outcome after a tibial shaft fracture

    DEFF Research Database (Denmark)

    Faergemann, C; Frandsen, P A; Röck, N D

    1999-01-01

    OBJECTIVE: A prospective study of 207 laymen and professionals answered a questionnaire regarding the expectations of the long-term outcome 6 months after a unilateral tibial shaft fracture. The aim was (1) to disclose the expected outcome after unilateral tibial shaft fracture, and (2) to compare...... these expectations with the outcome measured in patients. METHODS: There were five groups of nonpatients: (1) 42 orthopedic surgeons, (2) 36 physiotherapists, (3) 42 students, (4) 49 white collar workers, and (5) 38 blue collar workers. Outcome was measured by Sickness Impact Profile (SIP). The SIP scores were...

  20. Canine stifle joint biomechanics associated with tibial plateau leveling osteotomy predicted by use of a computer model.

    Science.gov (United States)

    Brown, Nathan P; Bertocci, Gina E; Marcellin-Little, Denis J

    2014-07-01

    To evaluate effects of tibial plateau leveling osteotomy (TPLO) on canine stifle joint biomechanics in a cranial cruciate ligament (CrCL)-deficient stifle joint by use of a 3-D computer model simulating the stance phase of gait and to compare biomechanics in TPLO-managed, CrCL-intact, and CrCL-deficient stifle joints. Computer simulations of the pelvic limb of a Golden Retriever. A previously developed computer model of the canine pelvic limb was used to simulate TPLO stabilization to achieve a tibial plateau angle (TPA) of 5° (baseline value) in a CrCL-deficient stifle joint. Sensitivity analysis was conducted for tibial fragment rotation of 13° to -3°. Ligament loads, relative tibial translation, and relative tibial rotation were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. TPLO with a 5° TPA converted cranial tibial translation to caudal tibial translation and increased loads placed on the remaining stifle joint ligaments, compared with results for a CrCL-intact stifle joint. Lateral collateral ligament load was similar, medial collateral ligament load increased, and caudal cruciate ligament load decreased after TPLO, compared with loads for a CrCL-deficient stifle joint. Relative tibial rotation after TPLO was similar to that of a CrCL-deficient stifle joint. Stifle joint biomechanics were affected by TPLO fragment rotation. In the model, stifle joint biomechanics were partially improved after TPLO, compared with CrCL-deficient stifle joint biomechanics, but TPLO did not fully restore CrCL-intact stifle joint biomechanics. Overrotation of the tibial fragment negatively influenced stifle joint biomechanics by increasing caudal tibial translation.

  1. Intraoperative study on anthropometry and gender differences of the proximal tibial plateau at the arthroplasty resection surface.

    Science.gov (United States)

    Yang, Bo; Yu, Jiakuo; Gong, Xi; Chen, Lianxu; Wang, Yongjian; Wang, Jian; Wang, Haijun; Zhang, Jiying

    2014-01-01

    The tibial plateau is asymmetric with a larger medial plateau. We observed from clinical practice that the shape of the tibial plateau does not always present a larger medial plateau. Tibial plateau also showed other shapes. The purpose of this study was to analyze the anthropometric data of the proximal tibia in a large group of Chinese patients undergoing total knee arthroplasty and to investigate the morphology of the resected proximal tibial surface and its gender differences. A total of 822 knees (164 males, 658 females) from the Chinese population were measured intraoperatively for medial anteroposterior (MAP) and lateral anteroposterior (LAP) dimensions of the resected proximal tibial surface. The difference of MAP and LAP (DML) was also calculated as MAP minus LAP. We then classified the data into three groups based on the DML (2 mm) to analyze the morphology of the proximal tibia and its distribution between male and female. The shape of proximal tibial plateau was of three types: larger medial plateau type, symmetric type, and larger lateral plateau type. There were significant differences between males and females in relation to the shape distribution of the proximal tibial plateau (P 2 mm and 120 of 822 (14.6%) tibia having a DMLDMLs to better match the different anthropometry of the resected tibial surface.

  2. [Sciatic nerve block "out-of-plane" distal to the bifurcation: effective and safe].

    Science.gov (United States)

    Geiser, T; Apel, J; Vicent, O; Büttner, J

    2017-03-01

    Ultrasound guided distal sciatic nerve block (DSB) at bifurcation level shows fast onset and provides excellent success rates. However, its safe performance might be difficult for the unexperienced physician. Just slightly distal to the bifurcation, the tibial nerve (TN) and common fibular nerve (CFN) can be shown clearly separated from each other. Therefore, we investigated if a block done here would provide similar quality results compared to the DSB proximally to the division, with a potentially lower risk of nerve damage. In this randomized, prospective trial, 56 patients per group received either a DSB distal to the bifurcation "out-of-plane" (dist.) or proximally "in-plane" (prox.) with 30 ml of Mepivacaine 1% each. Success was tested by a blinded examiner after 15 and 30 min respectively (sensory and motor block of TN and CFN: 0 = none, 2 = complete, change of skin temperature). Videos of the blocks were inspected by an independent expert retrospectively with regard to the spread of the local anesthetic (LA) and accidental intraneural injection. Cumulative single nerve measurements and temperature changes revealed significant shorter onset and better efficacy (dist/prox: 15 min: 3.13 ± 1.86/1.82 ± 1.62; 30 min: 5.73 ± 1.92/3.21 ± 1.88; T 15 min : 30.3 ± 3.48/28.0 ± 3.67, T 30 min . 33.0 ± 2.46/30.6 ± 3.86; MV/SD; ANOVA; p safe application of the LA, so an effective block can be done with just one injection. DSB slightly distal to the bifurcation, in an out-of-plane technique between the TN and CFN, can be done fast, effectively and safe.

  3. Immediate effects of modified landing pattern on a probabilistic tibial stress fracture model in runners.

    Science.gov (United States)

    Chen, T L; An, W W; Chan, Z Y S; Au, I P H; Zhang, Z H; Cheung, R T H

    2016-03-01

    Tibial stress fracture is a common injury in runners. This condition has been associated with increased impact loading. Since vertical loading rates are related to the landing pattern, many heelstrike runners attempt to modify their footfalls for a lower risk of tibial stress fracture. Such effect of modified landing pattern remains unknown. This study examined the immediate effects of landing pattern modification on the probability of tibial stress fracture. Fourteen experienced heelstrike runners ran on an instrumented treadmill and they were given augmented feedback for landing pattern switch. We measured their running kinematics and kinetics during different landing patterns. Ankle joint contact force and peak tibial strains were estimated using computational models. We used an established mathematical model to determine the effect of landing pattern on stress fracture probability. Heelstrike runners experienced greater impact loading immediately after landing pattern switch (Ptibial strains and the risk of tibial stress fracture in runners with different landing patterns (P>0.986). Immediate transitioning of the landing pattern in heelstrike runners may not offer timely protection against tibial stress fracture, despite a reduction of impact loading. Long-term effects of landing pattern switch remains unknown. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. The medial tibial stress syndrome. A cause of shin splints.

    Science.gov (United States)

    Mubarak, S J; Gould, R N; Lee, Y F; Schmidt, D A; Hargens, A R

    1982-01-01

    The medial tibial stress syndrome is a symptom complex seen in athletes who complain of exercise-induced pain along the distal posterior-medial aspect of the tibia. Intramuscular pressures within the posterior compartments of the leg were measured in 12 patients with this disorder. These pressures were not elevated and therefore this syndrome is a not a compartment syndrome. Available information suggests that the medial tibial stress syndrome most likely represents a periostitis at this location of the leg.

  5. Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    Hagspiel, Klaus D.; Bonatti, Hugo; Sabri, Saher; Arslan, Bulent; Harthun, Nancy L.

    2011-01-01

    Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

  6. A posterior tibial tendon skipping rope

    NARCIS (Netherlands)

    van Sterkenburg, M. N.; Haverkamp, D.; van Dijk, C. N.; Kerkhoffs, G. M. M. J.

    2010-01-01

    This report presents an athletic patient with swelling and progressive pain on the posteromedial side of his right ankle on weight bearing. MRI demonstrated tenosynovitis and suspicion of a length rupture. On posterior tibial tendoscopy, there was no rupture, but medial from the tendon a tissue cord

  7. Quadriceps force and anterior tibial force occur obviously later than vertical ground reaction force: a simulation study

    OpenAIRE

    Ueno, Ryo; Ishida, Tomoya; Yamanaka, Masanori; Taniguchi, Shohei; Ikuta, Ryohei; Samukawa, Mina; Saito, Hiroshi; Tohyama, Harukazu

    2017-01-01

    Background: Although it is well known that quadriceps force generates anterior tibial force, it has been unclear whether quadriceps force causes great anterior tibial force during the early phase of a landing task. The purpose of the present study was to examine whether the quadriceps force induced great anterior tibial force during the early phase of a landing task. Methods: Fourteen young, healthy, female subjects performed a single-leg landing task. Muscle force and anterior tibial force w...

  8. Intraoperative Vascular Neuromonitoring in Patients with Subarachnoid Hemorrhage: A Pilot Study Using Combined Laser-Doppler Spectrophotometry.

    Science.gov (United States)

    Schmitz, Emilija; Bischoff, Barbara; Wolf, Dennis; Schmitt, Hubert J; Eyupoglu, Ilker Y; Roessler, Karl; Buchfelder, Michael; Sommer, Björn

    2017-11-01

    Intraoperative monitoring of cerebral microcirculation in patients with subarachnoid hemorrhage (SAH) may predict the postoperative neurologic outcome. In this pilot study, we examined the value of a novel noninvasive real-time measurement technique for detecting changes in local microcirculation. We used the O2C (Oxygen to see) laser-Doppler spectrophotometry system in 14 patients with Hunt & Hess grade 2-5 SAH who underwent microsurgical cerebral aneurysm clipping. A subdural probe recorded capillary venous oxygenation (SO 2 ), relative hemoglobin concentration, blood cell velocity, and blood flow at a tissue depth of 7 mm. Data were recorded immediately before dural closure. We also recorded somatosensory evoked potentials (SEPs) with median and tibial nerve stimulation. Results were compared with neurologic performance, as measured on the modified Rankin Scale, at the day of discharge from the hospital and 12 months thereafter. Patient functional outcomes after discharge and 12 months were correlated with pathological decreased flow and increased SO 2 values. In 6 of 8 patients, microcirculatory monitoring parameters indicated ischemia during surgery, as shown by electrophysiological SEP changes and infarction detected on the postoperative computed tomography (CT) scan. Pathological SEP results correlated closely with infarct demarcation as seen on CT. Our results indicate the potential benefit of intraoperative combined laser-Doppler flowmetry and spectrophotometry for predicting postoperative clinical outcomes in this small patient sample. Larger-cohort testing is needed to verify our findings and show the possible merits of this novel method. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    Science.gov (United States)

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal

  10. Fraturas do planalto tibial Tibial plateau fractures

    Directory of Open Access Journals (Sweden)

    Maurício Kfuri Júnior

    2009-01-01

    Full Text Available As fraturas do planalto tibial são lesões articulares cujos princípios de tratamento envolvem a redução anatômica da superfície articular e a restauração funcional do eixo mecânico do membro inferior. Contribuem para a tomada de decisões no tratamento dessas fraturas o perfil do paciente, as condições do envelope de tecidos moles, a existência de outros traumatismos associados e a infraestrutura disponível para abordagens cirúrgicas. Para as fraturas de alta energia, o tratamento estagiado, seguindo o princípio do controle de danos, tem como prioridade a manutenção do alinhamento do membro enquanto se aguarda a resolução das más condições de tecidos moles. Já nos traumas de baixa energia, desde que os tecidos moles não sejam um fator adverso, o tratamento deve ser realizado em tempo único, com osteossíntese definitiva. Fixação estável e movimento precoce são variáveis diretamente relacionadas com os melhores prognósticos. Desenvolvimentos recentes, como os implantes com estabilidade angular, substitutos ósseos e imagens tridimensionais para controle intraoperatório, deverão contribuir para cirurgias menos invasivas e melhores resultados.Tibial plateau fractures are joint lesions that require anatomical reduction of joint surface and functional restoration of mechanical axis of a lower limb. Patient profile, soft tissue conditions, presence of associated injuries and the available infrastructure for the treatment all contribute to the decision making about the best treatment for these fractures. High-energy fractures are usually approached in a staged manner respecting the principle of damage control, and are primarily targeted to maintain limb alignment while the resolution unfavorable soft tissue conditions is pending. Low-energy trauma can be managed on a single-stage basis, provided soft tissues are not an adverse factor, with open reduction and internal f-ixation. Stable fixation and early painless joint

  11. [Cognitive rehabilitation in multiple sclerosis: preliminary results and presentation of a new program, PROCOG-SEP].

    Science.gov (United States)

    Brissart, H; Leroy, M; Debouverie, M

    2010-04-01

    Although cognitive disorders are well-known in multiple sclerosis (MS), even in earlier stages of the disease, their management may be overlooked. Our objective was to elaborate and evaluate the efficiency of a remedial program (PROCOG-SEP) designed for MS patients. The evidence-based program proposes exercises to both stimulate preserved functions and develop new abilities compensating for cognitive disabilities. Twenty-four patients with MS participated in 10/2-hour PROCOG-SEP sessions over a 6-month period. A neuropsychologist recorded BCcog-SEP performances before and after the PROCOG-SEP program. In addition, the same neuropsychologist conducted psychoclinical interviews to complete the before and after cognitive evaluations. The statistical analysis used the t-test performed with Excel. Compared with the initial levels, subtests of BCcog-SEP showing improvement after PROCOG-SEP were: verbal memory (SRT), visuospatial memory (10/36), verbal fluency (animal categories) and response to conflicting orders. Also, individual psychological interviews tended to be in favor of a general improvement in quality of life (more social interactions for instance). To our knowledge, the management program we have elaborated is the first designed to improve cognitive deficits in MS. These encouraging results suggest possibilities for improving cognition and thus quality-of-life in MS patients. 2009 Elsevier Masson SAS. All rights reserved.

  12. Outcomes of Surgical Treatment for Anterior Tibial Stress Fractures in Athletes: A Systematic Review.

    Science.gov (United States)

    Chaudhry, Zaira S; Raikin, Steven M; Harwood, Marc I; Bishop, Meghan E; Ciccotti, Michael G; Hammoud, Sommer

    2017-12-01

    Although most anterior tibial stress fractures heal with nonoperative treatment, some may require surgical management. To our knowledge, no systematic review has been conducted regarding surgical treatment strategies for the management of chronic anterior tibial stress fractures from which general conclusions can be drawn regarding optimal treatment in high-performance athletes. This systematic review was conducted to evaluate the surgical outcomes of anterior tibial stress fractures in high-performance athletes. Systematic review; Level of evidence, 4. In February 2017, a systematic review of the PubMed, MEDLINE, Cochrane, SPORTDiscus, and CINAHL databases was performed to identify studies that reported surgical outcomes for anterior tibial stress fractures. Articles meeting the inclusion criteria were screened, and reported outcome measures were documented. A total of 12 studies, published between 1984 and 2015, reporting outcomes for the surgical treatment of anterior tibial stress fractures were included in this review. All studies were retrospective case series. Collectively, surgical outcomes for 115 patients (74 males; 41 females) with 123 fractures were evaluated in this review. The overall mean follow-up was 23.3 months. The most common surgical treatment method reported in the literature was compression plating (n = 52) followed by drilling (n = 33). Symptom resolution was achieved in 108 of 123 surgically treated fractures (87.8%). There were 32 reports of complications, resulting in an overall complication rate of 27.8%. Subsequent tibial fractures were reported in 8 patients (7.0%). Moreover, a total of 17 patients (14.8%) underwent a subsequent procedure after their initial surgery. Following surgical treatment for anterior tibial stress fracture, 94.7% of patients were able to return to sports. The available literature indicates that surgical treatment of anterior tibial stress fractures is associated with a high rate of symptom resolution and return

  13. Displaced tibial shaft fractures treated with ASIF compression internal fixation

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Larsen, T K; Petersen, O C

    1990-01-01

    Fifty-one tibial shaft fractures treated by ASIF compression osteosynthesis were seen at follow-up at a median time of 46 weeks after injury. Twenty-four were open fractures and the patients received prophylactic antibiotics. The median stay in hospital was 15 days for open fractures and 6 days f...... for closed fractures. There were complications in 26 cases, with deep infection in 9 cases. At present we cannot advocate the use of ASIF compression osteosynthesis for displaced tibial fractures....

  14. End-to-side neurorrhaphy repairs peripheral nerve injury: sensory nerve induces motor nerve regeneration.

    Science.gov (United States)

    Yu, Qing; Zhang, She-Hong; Wang, Tao; Peng, Feng; Han, Dong; Gu, Yu-Dong

    2017-10-01

    End-to-side neurorrhaphy is an option in the treatment of the long segment defects of a nerve. It involves suturing the distal stump of the disconnected nerve (recipient nerve) to the side of the intimate adjacent nerve (donor nerve). However, the motor-sensory specificity after end-to-side neurorrhaphy remains unclear. This study sought to evaluate whether cutaneous sensory nerve regeneration induces motor nerves after end-to-side neurorrhaphy. Thirty rats were randomized into three groups: (1) end-to-side neurorrhaphy using the ulnar nerve (mixed sensory and motor) as the donor nerve and the cutaneous antebrachii medialis nerve as the recipient nerve; (2) the sham group: ulnar nerve and cutaneous antebrachii medialis nerve were just exposed; and (3) the transected nerve group: cutaneous antebrachii medialis nerve was transected and the stumps were turned over and tied. At 5 months, acetylcholinesterase staining results showed that 34% ± 16% of the myelinated axons were stained in the end-to-side group, and none of the myelinated axons were stained in either the sham or transected nerve groups. Retrograde fluorescent tracing of spinal motor neurons and dorsal root ganglion showed the proportion of motor neurons from the cutaneous antebrachii medialis nerve of the end-to-side group was 21% ± 5%. In contrast, no motor neurons from the cutaneous antebrachii medialis nerve of the sham group and transected nerve group were found in the spinal cord segment. These results confirmed that motor neuron regeneration occurred after cutaneous nerve end-to-side neurorrhaphy.

  15. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Yohei Tanikake

    2016-12-01

    Full Text Available A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  16. What is the optimal alignment of the tibial and femoral components in knee arthroplasty?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Korchi, Mounim; Thomsen, Morten G

    2014-01-01

    of positioning on survival and functional outcome was considered. Results - Many definitions exist when evaluating placement of femoral and tibial components. Implant alignment plays a role in both survival and functional outcome following primary TKA, as component malalignment can lead to increased failure......Background - Surgeon-dependent factors such as optimal implant alignment are thought to play a significant role in outcome following primary total knee arthroplasty (TKA). Exact definitions and references for optimal alignment are, however, still being debated. This overview of the literature...... describes different definitions of component alignment following primary TKA for (1) tibiofemoral alignment in the AP plane, (2) tibial and femoral component placement in the AP plane, (3) tibial and femoral component placement in the sagittal plane, and (4) rotational alignment of tibial and femoral...

  17. Open wedge high tibial osteotomy using three-dimensional printed models: Experimental analysis using porcine bone.

    Science.gov (United States)

    Kwun, Jun-Dae; Kim, Hee-June; Park, Jaeyoung; Park, Il-Hyung; Kyung, Hee-Soo

    2017-01-01

    The purpose of this study was to evaluate the usefulness of three-dimensional (3D) printed models for open wedge high tibial osteotomy (HTO) in porcine bone. Computed tomography (CT) images were obtained from 10 porcine knees and 3D imaging was planned using the 3D-Slicer program. The osteotomy line was drawn from the three centimeters below the medial tibial plateau to the proximal end of the fibular head. Then the osteotomy gap was opened until the mechanical axis line was 62.5% from the medial border along the width of the tibial plateau, maintaining the posterior tibial slope angle. The wedge-shaped 3D-printed model was designed with the measured angle and osteotomy section and was produced by the 3D printer. The open wedge HTO surgery was reproduced in porcine bone using the 3D-printed model and the osteotomy site was fixed with a plate. Accuracy of osteotomy and posterior tibial slope was evaluated after the osteotomy. The mean mechanical axis line on the tibial plateau was 61.8±1.5% from the medial tibia. There was no statistically significant difference (P=0.160). The planned and post-osteotomy correction wedge angles were 11.5±3.2° and 11.4±3.3°, and the posterior tibial slope angle was 11.2±2.2° pre-osteotomy and 11.4±2.5° post-osteotomy. There were no significant differences (P=0.854 and P=0.429, respectively). This study showed that good results could be obtained in high tibial osteotomy by using 3D printed models of porcine legs. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. CT determination of tibial tubercle lateralization in patients presenting with anterior knee pain

    Energy Technology Data Exchange (ETDEWEB)

    Jones, R.B. [Dept. of Physiology, School of Medicine, East Carolina Univ., Greenville, NC (United States); Bartlett, E.C. [Dept. of Surgery, School of Medicine, East Carolina Univ., Greenville, NC (United States); Vainright, J.R. [Dept. of Radiology, School of Medicine, East Carolina Univ., Greenville, NC (United States); Carrol, R.G. [Dept. of Physiology, School of Medicine, East Carolina Univ., Greenville, NC (United States)

    1995-10-01

    Using CT imaging with computerized technique to measure anatomic relationships, we evaluated patients (n = 50) with anterior knee pain for excessive lateralization of the tibial tubercle. The symptomatic knee of each patient was compared with their asymptomatic knee as well as with the knees of patients with other causes of anterior knee pain (n = 10) and with the knees of asymptomatic controls (n = 10). The symptomatic knee of patients with suspected patellofemoral malalignment demonstrated significantly greater lateralization of the tibial tubercle (12.2 {+-} 0.5 mm) than did the asymptomatic knee (9.0 {+-} 0.7 mm). The symptomatic knees of patients with patellofemoral malalignment also demonstrated significantly greater lateralization of the tibial tubercle than did the knees of patients with other causes of anterior knee pain (5.9 {+-} 0.9 mm). When a control population was added to the analysis, the patients with symptomatic patellofemoral malalignment demonstrated significantly greater lateralization of the tibial tubercle than did the controls (6.4 {+-} 0.4 mm). Using a critical value of 9 mm lateralization, the CT diagnosis of patellofemoral malalignment had a specificity of 95% and a sensitivity of 85%. We conclude that CT determination of tibial tubercle position assists the diagnosis of patellofemoral malalignment. (orig./MG)

  19. CT determination of tibial tubercle lateralization in patients presenting with anterior knee pain

    International Nuclear Information System (INIS)

    Jones, R.B.; Bartlett, E.C.; Vainright, J.R.; Carrol, R.G.

    1995-01-01

    Using CT imaging with computerized technique to measure anatomic relationships, we evaluated patients (n = 50) with anterior knee pain for excessive lateralization of the tibial tubercle. The symptomatic knee of each patient was compared with their asymptomatic knee as well as with the knees of patients with other causes of anterior knee pain (n = 10) and with the knees of asymptomatic controls (n = 10). The symptomatic knee of patients with suspected patellofemoral malalignment demonstrated significantly greater lateralization of the tibial tubercle (12.2 ± 0.5 mm) than did the asymptomatic knee (9.0 ± 0.7 mm). The symptomatic knees of patients with patellofemoral malalignment also demonstrated significantly greater lateralization of the tibial tubercle than did the knees of patients with other causes of anterior knee pain (5.9 ± 0.9 mm). When a control population was added to the analysis, the patients with symptomatic patellofemoral malalignment demonstrated significantly greater lateralization of the tibial tubercle than did the controls (6.4 ± 0.4 mm). Using a critical value of 9 mm lateralization, the CT diagnosis of patellofemoral malalignment had a specificity of 95% and a sensitivity of 85%. We conclude that CT determination of tibial tubercle position assists the diagnosis of patellofemoral malalignment. (orig./MG)

  20. Tibial and fibular angles in homozygous sickle cell disease

    International Nuclear Information System (INIS)

    Akamaguna, A.I.; Odita, J.C.; Ugbodaga, C.I.; Okafor, L.A.

    1986-01-01

    Measurements of the tibial and fibular angles made on ankle radiographs of 34 patients with sickle cell disease were compared with those of 36 normal Nigerians. Widening of the fibular angle, which is an indication of tibiotalar slant, was demonstrated in about 79% of sickle cell disease patients. By using fibular angle measurements as an objective method of assessing subtle tibiotalar slant, it is concluded that the incidence of this deformity is much higher among sickle cell disease patients than previously reported. The mean values of tibial and fibular angles in normal Nigerians are higher than has been reported amongst Caucasians. (orig.)

  1. A novel approach to 32-channel peripheral nervous system myelin imaging in vivo, with single axon resolution.

    Science.gov (United States)

    Grochmal, Joey; Teo, Wulin; Gambhir, Hardeep; Kumar, Ranjan; Stratton, Jo Anne; Dhaliwal, Raveena; Brideau, Craig; Biernaskie, Jeff; Stys, Peter K; Midha, Rajiv

    2018-01-19

    OBJECTIVE Intravital spectral imaging of the large, deeply situated nerves in the rat peripheral nervous system (PNS) has not been well described. Here, the authors have developed a highly stable platform for performing imaging of the tibial nerve in live rodents, thus allowing the capture of high-resolution, high-magnification spectral images requiring long acquisition times. By further exploiting the qualities of the topically applied myelin dye Nile red, this technique is capable of visualizing the detailed microenvironment of peripheral nerve demyelination injury and recovery, while allowing us to obtain images of exogenous Schwann cell myelination in a living animal. METHODS The authors caused doxorubicin-induced focal demyelination in the tibial nerves of 25 Thy-1 GFP rats, of which 2 subsets (n = 10 each) received either BFP-labeled SKP-SCs or SCs to the zone of injury. Prior to acquiring images of myelin recovery in these nerves, a tibial nerve window was constructed using a silicone hemitube, a fast drying silicone polymer, and a small coverslip. This construct was then affixed to a 3D-printed nerve stage, which in turn was affixed to an external fixation/microscope stage device. Myelin visualization was facilitated by the topical application of Nile red. RESULTS The authors reliably demonstrated intravital peripheral nerve myelin imaging with micron-level resolution and magnification, and minimal movement artifact. The detailed microenvironment of nerve remyelination can be vividly observed, while exogenously applied Schwann cells and skin-derived precursor Schwann cells can be seen myelinating axons. CONCLUSIONS Topically applied Nile red enables intravital study of myelin in the living rat PNS. Furthermore, the use of a tibial nerve window facilitates stable intravital peripheral nerve imaging, making possible high-definition spectral imaging with long acquisition times.

  2. Passive Posterior Tibial Subluxation on Routine Knee MRI as a Secondary Sign of PCL Tear

    International Nuclear Information System (INIS)

    Degnan, A.J.; Adam, R.J.; Maldjian, C.; Harner, Ch.D.

    2014-01-01

    The posterior drawer test is an accurate clinical test to diagnose posterior cruciate ligament (PCL), indicating laxity of the PCL that allows posterior tibial translation. This study aimed to determine whether posterior tibial translation relative to the femur on routine MRI could serve as an additional sign of PCL tear. Routine knee MRI in eleven patients (7 males, 4 females) with arthroscopically confirmed isolated PCL tears were reviewed independently by two musculoskeletal radiologists. Measurements of tibial translation were made in the medial and lateral compartments of patients and controls (10 males, 12 females) without clinical or MRI evidence of ligament injury. Significant medial compartment posterior tibial translation was present in patients with PCL tear compared to controls (+2.93 mm versus +0.03 mm, Ρ=0.002) with excellent interobserver agreement (intraclass correlation coefficient (ICC) = 0.94). No significant difference in lateral compartment tibial translation was observed (+0.17 mm versus -0.57 mm, Ρ=0.366) despite excellent interobserver agreement (ICC = 0.96). Posterior tibial translation in the midmedial compartment may be a secondary sign of isolated PCL tear on routine knee MRI with passive extension without manipulation or weight bearing. Additional work in a larger cohort may better address the accuracy of this finding

  3. Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures

    Directory of Open Access Journals (Sweden)

    TONG Da-ke

    2012-02-01

    Full Text Available 【Abstract】Objective: To investigate the efficacy of the locking internal fixator (LIF, which includes the locking compression plate (LCP and the less invasive stable system (LISS, in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthesis (MIPO technique. The data consisted of 43 proximal tibial fractures (type AO41C3 and 55 distal tibial fractures (type AO43C3. Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months. Only two cases of delayed union occurred at postoperative 10 months. No infections were reported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at postoperative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing. Key words: Internal fixator; Tibial fractures; Fracture fixation, intramedullary; Bone plates

  4. Absent SEP during therapeutic hypothermia did not reappear after re-warming in comatose patients following cardiac arrest.

    Science.gov (United States)

    Grippo, A; Carrai, R; Fossi, S; Cossu, C; Mazzeschi, E; Peris, A; Bonizzoli, M; Ciapetti, M; Gensini, G F; Pinto, F; Amantini, A

    2013-04-01

    Early prediction of neurological outcome for patients resuscitated from cardiac arrest (CA) is a challenging task. Therapeutic hypothermia (TH) has been shown to improve neurological outcome after CA. Two recent studies indicated that somatosensory evoked potentials (SEP) recorded during TH retains high prediction value for poor neurological outcome. It remains unclear whether TH can influence the recovery of bilaterally absent (BA) N20 after re-warming. The primary endpoint of the present study was to evaluate if patients with BA SEPs during TH can recover cortical responses after re-warming. The secondary endpoint was to evaluate whether BA SEPs recorded during TH retains its prediction value for poor neurological outcome as in normothermic patients. A single centre prospective cohort study including comatose adults resuscitated from in/out-of-hospital CA treated with TH. SEPs were recorded during TH (6-24 hours after CA) and after re-warming in those patients who remained comatose. Neurological outcome was assessed 6 months after CA using the Glasgow Outcome Scale. Sixty patients were included. In patients with preserved SEP, no significant differences were found between N20 mean amplitude during TH and after re-warming. During TH, 24 patients showed bilaterally absent N20 but none of these recovered cortical responses after re-warming. All patients with absent SEPs during TH did not recover consciousness. In a single centre cohort of comatose CA patients, our results showed that all patients with absent SEPs during early recording (6-24 hours) during TH showed bilaterally absent SEPs after re-warming. As a secondary result we confirmed previous data that BA SEPs during TH retains its prognostic value for poor neurological outcome, as in normothermic patients.

  5. Bacillus subtilis SepF binds to the C-terminus of FtsZ.

    Science.gov (United States)

    Król, Ewa; van Kessel, Sebastiaan P; van Bezouwen, Laura S; Kumar, Neeraj; Boekema, Egbert J; Scheffers, Dirk-Jan

    2012-01-01

    Bacterial cell division is mediated by a multi-protein machine known as the "divisome", which assembles at the site of cell division. Formation of the divisome starts with the polymerization of the tubulin-like protein FtsZ into a ring, the Z-ring. Z-ring formation is under tight control to ensure bacteria divide at the right time and place. Several proteins bind to the Z-ring to mediate its membrane association and persistence throughout the division process. A conserved stretch of amino acids at the C-terminus of FtsZ appears to be involved in many interactions with other proteins. Here, we describe a novel pull-down assay to look for binding partners of the FtsZ C-terminus, using a HaloTag affinity tag fused to the C-terminal 69 amino acids of B. subtilis FtsZ. Using lysates of Escherichia coli overexpressing several B. subtilis cell division proteins as prey we show that the FtsZ C-terminus specifically pulls down SepF, but not EzrA or MinC, and that the interaction depends on a conserved 16 amino acid stretch at the extreme C-terminus. In a reverse pull-down SepF binds to full-length FtsZ but not to a FtsZΔC16 truncate or FtsZ with a mutation of a conserved proline in the C-terminus. We show that the FtsZ C-terminus is required for the formation of tubules from FtsZ polymers by SepF rings. An alanine-scan of the conserved 16 amino acid stretch shows that many mutations affect SepF binding. Combined with the observation that SepF also interacts with the C-terminus of E. coli FtsZ, which is not an in vivo binding partner, we propose that the secondary and tertiary structure of the FtsZ C-terminus, rather than specific amino acids, are recognized by SepF.

  6. Bacillus subtilis SepF binds to the C-terminus of FtsZ.

    Directory of Open Access Journals (Sweden)

    Ewa Król

    Full Text Available Bacterial cell division is mediated by a multi-protein machine known as the "divisome", which assembles at the site of cell division. Formation of the divisome starts with the polymerization of the tubulin-like protein FtsZ into a ring, the Z-ring. Z-ring formation is under tight control to ensure bacteria divide at the right time and place. Several proteins bind to the Z-ring to mediate its membrane association and persistence throughout the division process. A conserved stretch of amino acids at the C-terminus of FtsZ appears to be involved in many interactions with other proteins. Here, we describe a novel pull-down assay to look for binding partners of the FtsZ C-terminus, using a HaloTag affinity tag fused to the C-terminal 69 amino acids of B. subtilis FtsZ. Using lysates of Escherichia coli overexpressing several B. subtilis cell division proteins as prey we show that the FtsZ C-terminus specifically pulls down SepF, but not EzrA or MinC, and that the interaction depends on a conserved 16 amino acid stretch at the extreme C-terminus. In a reverse pull-down SepF binds to full-length FtsZ but not to a FtsZΔC16 truncate or FtsZ with a mutation of a conserved proline in the C-terminus. We show that the FtsZ C-terminus is required for the formation of tubules from FtsZ polymers by SepF rings. An alanine-scan of the conserved 16 amino acid stretch shows that many mutations affect SepF binding. Combined with the observation that SepF also interacts with the C-terminus of E. coli FtsZ, which is not an in vivo binding partner, we propose that the secondary and tertiary structure of the FtsZ C-terminus, rather than specific amino acids, are recognized by SepF.

  7. Ischial hypoplasia, tibial hypoplasia and facial abnormalities: a new syndrome?

    International Nuclear Information System (INIS)

    Nishimura, G.; Haga, Yoshihiko; Aoki, Katsuhiko; Hasegawa, Tomoko

    1998-01-01

    A child with facial abnormalities, short stature and a variety of skeletal alterations is reported. The facial abnormalities comprised low-set ears, short nose with a long philtrum, micrognathia and cleft palate. The skeletal alterations included ischial hypoplasia, malformations of the cervical spine, hypoplasia of the lesser trochanters, tibial hypoplasia with bowing of the lower legs, tibio-fibular diastasis with malformed distal tibial epiphyses, clubfeet and brachymesophalangy. The constellation of clinical and radiological findings in the present patient do not fit any known malformation syndrome. (orig.)

  8. Electrical muscle stimulation elevates intramuscular BDNF and GDNF mRNA following peripheral nerve injury and repair in rats.

    Science.gov (United States)

    Willand, Michael P; Rosa, Elyse; Michalski, Bernadeta; Zhang, Jennifer J; Gordon, Tessa; Fahnestock, Margaret; Borschel, Gregory H

    2016-10-15

    Despite advances in surgery, patients with nerve injuries frequently have functional deficits. We previously demonstrated in a rat model that daily electrical muscle stimulation (EMS) following peripheral nerve injury and repair enhances reinnervation, detectable as early as two weeks post-injury. In this study, we explain the enhanced early reinnervation observed with electrical stimulation. In two groups of rats, the tibial nerve was transected and immediately repaired. Gastrocnemius muscles were implanted with intramuscular electrodes for sham or muscle stimulation. Muscles were stimulated daily, eliciting 600 contractions for one hour/day, repeated five days per week. Sixteen days following nerve injury, muscles were assessed for functional reinnervation by motor unit number estimation methods using electromyographic recording. In a separate cohort of rats, surgical and electrical stimulation procedures were identical but muscles and distal nerve stumps were harvested for molecular analysis. We observed that stimulated muscles had significantly higher motor unit number counts. Intramuscular levels of brain-derived and glial cell line-derived neurotrophic factor (BDNF and GDNF) mRNA were significantly upregulated in muscles that underwent daily electrical stimulation compared to those without stimulation. The corresponding levels of trophic factor mRNA within the distal stump were not different from one another, indicating that the intramuscular electrical stimulus does not modulate Schwann cell-derived trophic factor transcription. Stimulation over a three-month period maintained elevated muscle-derived GDNF but not BDNF mRNA. In conclusion, EMS elevates intramuscular trophic factor mRNA levels which may explain how EMS enhances neural regeneration following nerve injury. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  9. Quantitative Comparison of the Microscopic Anatomy of the Human ACL Femoral and Tibial Entheses

    Science.gov (United States)

    Beaulieu, Mélanie L.; Carey, Grace E.; Schlecht, Stephen H.; Wojtys, Edward M.; Ashton-Miller, James A.

    2015-01-01

    The femoral enthesis of the human anterior cruciate ligament (ACL) is known to be more susceptible to injury than the tibial enthesis. To determine whether anatomic differences might help explain this difference, we quantified the microscopic appearance of both entheses in 15 unembalmed knee specimens using light microscopy, toluidine blue stain and image analysis. The amount of calcified fibrocartilage and uncalcified fibrocartilage, and the ligament entheseal attachment angle were then compared between the femoral and tibial entheses via linear mixed-effects models. The results showed marked differences in anatomy between the two entheses. The femoral enthesis exhibited a 3.9-fold more acute ligament attachment angle than the tibial enthesis (p fibrocartilage tissue area (p fibrocartilage depth (p fibrocartilage and a more acute ligament attachment angle than the tibial enthesis, which provides insight into why it is more vulnerable to failure. PMID:26134706

  10. Acute changes in foot strike pattern and cadence affect running parameters associated with tibial stress fractures.

    Science.gov (United States)

    Yong, Jennifer R; Silder, Amy; Montgomery, Kate L; Fredericson, Michael; Delp, Scott L

    2018-05-18

    Tibial stress fractures are a common and debilitating injury that occur in distance runners. Runners may be able to decrease tibial stress fracture risk by adopting a running pattern that reduces biomechanical parameters associated with a history of tibial stress fracture. The purpose of this study was to test the hypothesis that converting to a forefoot striking pattern or increasing cadence without focusing on changing foot strike type would reduce injury risk parameters in recreational runners. Running kinematics, ground reaction forces and tibial accelerations were recorded from seventeen healthy, habitual rearfoot striking runners while running in their natural running pattern and after two acute retraining conditions: (1) converting to forefoot striking without focusing on cadence and (2) increasing cadence without focusing on foot strike. We found that converting to forefoot striking decreased two risk factors for tibial stress fracture: average and peak loading rates. Increasing cadence decreased one risk factor: peak hip adduction angle. Our results demonstrate that acute adaptation to forefoot striking reduces different injury risk parameters than acute adaptation to increased cadence and suggest that both modifications may reduce the risk of tibial stress fractures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Relevance of near-Earth magnetic field modeling in deriving SEP properties using ground-based data

    Science.gov (United States)

    Kanellakopoulos, Anastasios; Plainaki, Christina; Mavromichalaki, Helen; Laurenza, Monica; Gerontidou, Maria; Storini, Marisa; Andriopoulou, Maria

    2014-05-01

    Ground Level Enhancements (GLEs) are short-term increases observed in cosmic ray intensity records of ground-based particle detectors such as neutron monitors (NMs) or muon detectors; they are related to the arrival of solar relativistic particles in the terrestrial environment. Hence, GLE events are related to the most energetic class of solar energetic particle (SEP) events. In this work we investigate how the use of different magnetospheric field models can influence the derivation of the relativistic SEP properties when modeling GLE events. As a case study, we examine the event of 2012 May 17 (also known as GLE71), registered by ground-based NMs. We apply the Tsyganenko 89 and the Tsyganenko 96 models in order to calculate the trajectories of the arriving SEPs in the near-Earth environment. We show that the intersection of the SEP trajectories with the atmospheric layer at ~20 km from the Earth's surface (i.e., where the flux of the generated secondary particles is maximum), forms for each ground-based neutron monitor a specified viewing region that is dependent on the magnetospheric field configuration. Then, we apply the Neutron Monitor Based Anisotropic GLE Pure Power Law (NMBANGLE PPOLA) model (Plainaki et al. 2010, Solar Phys, 264, 239), in order to derive the spectral properties of the related SEP event and the spatial distributions of the SEP fluxes impacting the Earth's atmosphere. We examine the dependence of the results on the used magnetic field models and evaluate their range of validity. Finally we discuss information derived by modeling the SEP spectrum in the frame of particle acceleration scenarios.

  12. Mutational analysis of Sep-tRNA:Cys-tRNA synthase reveals critical residues for tRNA-dependent cysteine formation.

    Science.gov (United States)

    Helgadóttir, Sunna; Sinapah, Sylvie; Söll, Dieter; Ling, Jiqiang

    2012-01-02

    In methanogenic archaea, Sep-tRNA:Cys-tRNA synthase (SepCysS) converts Sep-tRNA(Cys) to Cys-tRNA(Cys). The mechanism of tRNA-dependent cysteine formation remains unclear due to the lack of functional studies. In this work, we mutated 19 conserved residues in Methanocaldococcus jannaschii SepCysS, and employed an in vivo system to determine the activity of the resulting variants. Our results show that three active-site cysteines (Cys39, Cys42 and Cys247) are essential for SepCysS activity. In addition, combined with structural modeling, our mutational and functional analyses also reveal multiple residues that are important for the binding of PLP, Sep and tRNA. Our work thus represents the first systematic functional analysis of conserved residues in archaeal SepCysSs, providing insights into the catalytic and substrate binding mechanisms of this poorly characterized enzyme. Copyright © 2011 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  13. Three-layer microfibrous peripheral nerve guide conduit composed of elastin-laminin mimetic artificial protein and poly(L-lactic acid

    Directory of Open Access Journals (Sweden)

    Sachiro eKakinoki

    2014-07-01

    Full Text Available We developed a microfibrous poly(L-lactic acid (PLLA nerve conduit with a three-layered structure to simultaneously enhance nerve regeneration and prevent adhesion of surrounding tissue. The inner layer was composed of PLLA microfiber containing 25% elastin-laminin mimetic protein (AG73-(VPGIG30 that promotes neurite outgrowth. The thickest middle layer was constructed of pure PLLA microfibers that impart the large mechanical stremgth to the conduit. A 10% poly(ethylene glycol was added to the outer layer to prevent the adhesion with the surrounding tissue. The AG73-(VPGIG30 composisting of an elastin-like repetitive sequence (VPGIG30 and a laminin-derived sequence (RKRLQVQLSIRT: AG73 was biosynthesized using Escherichia coli. The PLLA microfibrous conduits were fabricated using an electrospinning procedure. AG73-(VPGIG30 was successfully mixed in the PLLA microfibers, and the PLLA/AG73-(VPGIG30 microfibers were stable under physiological conditions. The PLLA/AG73-(VPGIG30 microfibers enhanced adhesion and neurite outgrowth of PC12 cells. The electrospun microfibrous conduit with a three-layered structure was implanted for bridging a 2.0-cm gap in the tibial nerve of a rabbit. Two months after implantation, no adhesion of surrounding tissue was observed, and the action potential was slightly improved in the nerve conduit with the PLLA/AG73-(VPGIG30 inner layer.

  14. Three-layer microfibrous peripheral nerve guide conduit composed of elastin-laminin mimetic artificial protein and poly(L-lactic acid)

    Science.gov (United States)

    Kakinoki, Sachiro; Nakayama, Midori; Moritan, Toshiyuki; Yamaoka, Tetsuji

    2014-07-01

    We developed a microfibrous poly(L-lactic acid) (PLLA) nerve conduit with a three-layered structure to simultaneously enhance nerve regeneration and prevent adhesion of surrounding tissue. The inner layer was composed of PLLA microfiber containing 25% elastin-laminin mimetic protein (AG73-(VPGIG)30) that promotes neurite outgrowth. The thickest middle layer was constructed of pure PLLA microfibers that impart the large mechanical stremgth to the conduit. A 10% poly(ethylene glycol) was added to the outer layer to prevent the adhesion with the surrounding tissue. The AG73-(VPGIG)30 composisting of an elastin-like repetitive sequence (VPGIG)30 and a laminin-derived sequence (RKRLQVQLSIRT: AG73) was biosynthesized using Escherichia coli. The PLLA microfibrous conduits were fabricated using an electrospinning procedure. AG73-(VPGIG)30 was successfully mixed in the PLLA microfibers, and the PLLA/AG73-(VPGIG)30 microfibers were stable under physiological conditions. The PLLA/AG73-(VPGIG)30 microfibers enhanced adhesion and neurite outgrowth of PC12 cells. The electrospun microfibrous conduit with a three-layered structure was implanted for bridging a 2.0-cm gap in the tibial nerve of a rabbit. Two months after implantation, no adhesion of surrounding tissue was observed, and the action potential was slightly improved in the nerve conduit with the PLLA/AG73-(VPGIG)30 inner layer.

  15. Ischial hypoplasia, tibial hypoplasia and facial abnormalities: a new syndrome?

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, G. [Department of Radiology, Dokkyo University School of Medicine (Japan); Haga, Yoshihiko [Department of Orthopaedics, Shizuoka Children`s Hospital, Shizuoka (Japan); Aoki, Katsuhiko [Department of Radiology, Shizuoka Children`s Hospital, Shizuoka (Japan); Hasegawa, Tomoko [Division of Clinical Genetics, Shizuoka Children`s Hospital, Shizuoka (Japan)

    1998-12-01

    A child with facial abnormalities, short stature and a variety of skeletal alterations is reported. The facial abnormalities comprised low-set ears, short nose with a long philtrum, micrognathia and cleft palate. The skeletal alterations included ischial hypoplasia, malformations of the cervical spine, hypoplasia of the lesser trochanters, tibial hypoplasia with bowing of the lower legs, tibio-fibular diastasis with malformed distal tibial epiphyses, clubfeet and brachymesophalangy. The constellation of clinical and radiological findings in the present patient do not fit any known malformation syndrome. (orig.) With 4 figs., 8 refs.

  16. Tibial Fractures in Alpine Skiing and Snowboarding in Finland: A Retrospective Study on Fracture Types and Injury Mechanisms in 363 Patients.

    Science.gov (United States)

    Stenroos, A; Pakarinen, H; Jalkanen, J; Mälkiä, T; Handolin, L

    2016-09-01

    Alpine skiing and snowboarding share the hazards of accidents accounting for tibial fractures. The aim of this study was to evaluate the fracture patterns and mechanisms of injury of tibial fractures taking place in downhill skiing and snowboarding. All patients with tibial fracture due to alpine skiing or snowboarding accident treated in four trauma centers next to the largest ski resorts in Finland were analyzed between 2006 and 2012. The hospital records were retrospectively reviewed for data collection: equipment used (skis or snowboard), age, gender, and mechanism of injury. Fractures were classified according to AO-classification. There were 342 skiing and 30 snowboarding related tibial fractures in 363 patients. Tibial shaft fracture was the most common fracture among skiers (n = 215, 63%), followed by proximal tibial fractures (n = 92, 27%). Snowboarders were most likely to suffer from proximal tibial fracture (13, 43%) or tibial shaft fracture (11, 37%). Snowboarders were also more likely than skiers to suffer complex AO type C fractures (23% vs 9%, p jumping (46%). The most important finding was the relatively high number of the tibial plateau fractures among adult skiers. The fracture patterns between snowboarding and skiing were different; the most common fracture type in skiers was spiral tibial shaft fracture compared to proximal tibial fractures in snowboarders. Children had more simple fractures than adults. © The Finnish Surgical Society 2016.

  17. Does Tibial Slope Affect Perception of Coronal Alignment on a Standing Anteroposterior Radiograph?

    Science.gov (United States)

    Schwartz, Adam J; Ravi, Bheeshma; Kransdorf, Mark J; Clarke, Henry D

    2017-07-01

    A standing anteroposterior (AP) radiograph is commonly used to evaluate coronal alignment following total knee arthroplasty (TKA). The impact of coronal alignment on TKA outcomes is controversial, perhaps due to variability in imaging and/or measurement technique. We sought to quantify the effect of image rotation and tibial slope on coronal alignment. Using a standard extramedullary tibial alignment guide, 3 cadaver legs were cut to accept a tibial tray at 0°, 3°, and 7° of slope. A computed tomography scan of the entire tibia was obtained for each specimen to confirm neutral coronal alignment. Images were then obtained at progressive 10° intervals of internal and external rotation up to 40° maximum in each direction. Images were then randomized and 5 blinded TKA surgeons were asked to determine coronal alignment. Continuous data values were transformed to categorical data (neutral [0], valgus [L], and varus [R]). Each 10° interval of external rotation of a 7° sloped tibial cut (or relative internal rotation of a tibial component viewed in the AP plane) resulted in perception of an additional 0.75° of varus. The slope of the proximal tibia bone cut should be taken into account when measuring coronal alignment on a standing AP radiograph. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Ultrasonographic findings in hereditary neuropathy with liability to pressure palsies.

    Science.gov (United States)

    Bayrak, Ayse O; Bayrak, Ilkay Koray; Battaloglu, Esra; Ozes, Burcak; Yildiz, Onur; Onar, Musa Kazim

    2015-02-01

    The aims of this study were to evaluate the sonographic findings of patients with hereditary neuropathy with liability to pressure palsies (HNPP) and to examine the correlation between sonographic and electrophysiological findings. Nine patients whose electrophysiological findings indicated HNPP and whose diagnosis was confirmed by genetic analysis were enrolled in the study. The median, ulnar, peroneal, and tibial nerves were evaluated by ultrasonography. We ultrasonographically evaluated 18 median, ulnar, peroneal, and tibial nerves. Nerve enlargement was identified in the median, ulnar, and peroneal nerves at the typical sites of compression. None of the patients had nerve enlargement at a site of noncompression. None of the tibial nerves had increased cross-sectional area (CSA) values. There were no significant differences in median, ulnar, and peroneal nerve distal motor latencies (DMLs) between the patients with an increased CSA and those with a normal CSA. In most cases, there was no correlation between electrophysiological abnormalities and clinical or sonographic findings. Although multiple nerve enlargements at typical entrapment sites on sonographic evaluation can suggest HNPP, ultrasonography cannot be used as a diagnostic tool for HNPP. Ultrasonography may contribute to the differential diagnosis of HNPP and other demyelinating polyneuropathies or compression neuropathies; however, further studies are required.

  19. A gastrocnemius heterotopical transplant model with end-to-side neurorraphy.

    Science.gov (United States)

    Jaeger, Marcos Ricardo de Oliveira; Silva, Jefferson Luis Braga; Bain, James; Ely, Pedro Bins; Pires, Jefferson André; Ferreira, Lydia Masako

    2014-01-01

    To present an animal model to assess the effects of end-to-side innervation in the heterotopically transplanted model with reduced chances of neural contamination. The medial portion of the gastrocnemius muscle in wistar male rats was isolated and its pedicle dissected and performed a flap in the abdominal portion. To prevent neural contamination in the abdominal region, the muscle was wrapped with a Goretex(r) sheet. The specimens were divided into 2 groups (G). In G1 was performed an end-to-end suture between tibial nerve of the gastrocnemius and femoral motor nerve and between the saphenous sensory nerve and the motor nerve. In G2 was performed a end-to-side suture between the tibial nerve and the motor femoral and between the tibial nerve and saphenous motor nerve. The specimens were evaluated 60 days later to check the structure of the neurorraphy. Sections were obtained proximal and distal to the coaptation site. The medial gastrocnemius muscle had the advantage of maintaining visible mass after 60 days. No disruption of the coaptation site was found. No major injury to the donor nerve was seen in group 2. The proposed model is simple, reproduciple and prevent the neural contamination in the flap in end-to-side suture.

  20. Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report.

    Science.gov (United States)

    Ozdemir, Guzelali; Azboy, Ibrahim; Yilmaz, Baris

    2016-01-01

    Periprosthetic fractures around the knee after total knee arthroplasty can be seen in the femur, tibia and patella. The tibial fractures are rare cases. Our case with bilateral tibial stress fracture developed after total knee arthroplasty (TKA) is the first of its kind in the literature. 75-year-old male patient with bilateral knee osteoarthritis had not benefited from conservative treatment methods previously applied. Left TKA was applied. In the second month postoperatively, periprosthetic tibial fracture was identified and osteosynthesis was implemented with locked tibia proximal plate-screw. Bone union in 12 weeks was observed in his follow-ups. After 15 months of his first operation, TKA was applied to the right knee. Postoperatively in the second month, as in the first operation, periprosthetic tibial fracture was detected. Osteosynthesis with locking plate-screw was applied and union in 12 weeks was observed in his follow-up. He was seen mobilized independently and without support in the last control of the case made in the 24th month after the second operation. The number of TKA applications is expected to increase in the future. The incidence of periprosthetic fractures should also be expected to increase in these cases. Periprosthetic tibial fractures after TKA are rarely seen. The treatment of periprosthetic fractures around the knee after TKA can be difficult. In the case of persistent pain in the upper end of the tibia after the surgery, stress fracture should be considered. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Quantitative analysis of scintigraphic findings in tibial stress fractures in Thoroughbred racehorses.

    Science.gov (United States)

    Valdés-Martínez, Alejandro; Seiler, Gabriela; Mai, Wilfried; Bolt, David M; Mudge, Margaret; Dukti, Sarah A; Hubert, Jeremy D

    2008-07-01

    To develop a quantitative method of interpreting tibial scintigrams of Thoroughbred racehorses with tibial stress fractures that may facilitate diagnosis of fractures and to provide prognostic information regarding future performance of affected horses. 35 Thoroughbred racehorses. Static bone-phase scintigrams of tibial stress fractures were quantitatively analyzed by use of ratios of the mean radionuclide counts per pixel in a region of interest (ROI) drawn around the area of increased uptake of radiopharmaceutical to mean counts per pixel in a second ROI drawn around an apparently normal area of the tibial diaphysis. In horses with unilateral fractures, ratios for the contralateral tibia were determined by use of 2 ROIs drawn at the same positions as the ROIs in the fractured tibia. Ratios were compared between fractured versus apparently normal tibias, between horses that returned to racing versus those that did not, and among horses with various grades of lameness. The association between ratios for fractured tibias and intervals between diagnosis and return to racing was also assessed. Mean ratio of ROIs in apparently normal tibias was 1.35 (95% confidence interval [CI], 1.21 to 1.50); that in tibias with stress fractures was 3.55 (95% CI, 2.50 to 4.60). These ratios were significantly different. None of the associations between ratios for fractured tibias and grades of lameness or performance outcomes were significant. Tibial stress fracture scintigrams can be quantitatively analyzed. A prospective study with a controlled rehabilitation period is necessary to evaluate the possible applications of this method.

  2. The Effect of Patient-Specific Instrumentation Incorporating an Extramedullary Tibial Guide on Operative Efficiency for Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Oh-Ryong Kwon

    2017-01-01

    Full Text Available This retrospective study was to determine if patient-specific instrumentation (PSI for total knee arthroplasty (TKA leads to shortened surgical time through increased operating room efficiency according to different tibial PSI designs. 166 patients underwent primary TKA and were categorized into three groups as follows: PSI without extramedullary (EM tibial guide (group 1, n=48, PSI with EM tibial guide (group 2, n=68, and conventional instrumentation (CI group (group 3, n=50. Four factors were compared between groups, namely, operative room time, thickness of bone resection, tibial slope, and rotation of the component. The mean surgical time was significantly shorter in the PSI with EM tibial guide group (group 2, 63.9±13.6 min compared to the CI group (group 3, 82.8±24.9 min (P<0.001. However, there was no significant difference in the PSI without EM tibial guide group (group 1, 75.3±18.8 min. This study suggests that PSI incorporating an EM tibial guide may lead to high operative efficiency in TKA compared to CI. This trial is registered with KCT0002384.

  3. Management of open fractures of the tibial shaft in multiple trauma

    Directory of Open Access Journals (Sweden)

    Stanislaw Boltuc

    2008-01-01

    Full Text Available Background: The work presents the assessment of the results of treatment of open tibial shaft fractures in polytrauma patients. Materials and Methods: The study group comprised 28 patients who underwent surgical treatment of open fractures of the tibial shaft with locked intramedullary nailing. The mean age of the patients was 43 years (range from 19 to 64 years. The criterion for including the patients in the study was concomitant multiple trauma. For the assessment of open tibial fractures, Gustilo classification was used. The most common concomitant multiple trauma included craniocerebral injuries, which were diagnosed in 12 patients. In 14 patients, the surgery was performed within 24 h after the injury. In 14 patients, the surgery was delayed and was performed 8-10 days after the trauma. Results: The assessment of the results at 12 months after the surgery included the following features: time span between the trauma and the surgery and complications in the form of osteomyelitis and delayed union. The efficacy of gait, muscular atrophy, edema of the operated limb and possible disturbances of its axis were also taken under consideration. In patients operated emergently within 24 h after the injury, infected nonunion was observed in three (10.8% males. These patients had grade III open fractures of the tibial shaft according to Gustilo classification. No infectious complications were observed in patients who underwent a delayed operation. Conclusion: Evaluation of patients with open fractures of the tibial shaft in multiple trauma showed that delayed intramedullary nailing performed 8-10 days after the trauma, resulted in good outcome and avoided development of delayed union and infected nonunion. This approach gives time for stabilization of general condition of the patient and identification of pathogens from wound culture.

  4. Therapeutical Management of the Tibial Plateau Fractures

    Directory of Open Access Journals (Sweden)

    Obada B.

    2016-11-01

    Full Text Available The study was aimed to identify the role of surgical treatment of tibial plateau fractures, its functional outcome and complications. Demographic data for the patients and details of current clinical and radiological follow-up findings were obtained to assess range of motion, clinical stability, alignment of the knee, and posttraumatic arthrosis (Kellgren/Lawrence score. 64 cases of tibial plateau fractures treated by different surgical methods and variuos implants type were studied from 2013 to 2015 and followed-up for minimum period of 6 months. The systematisation of the casuitry was made using Schatzker and AO classifications. The treatment methods consist of: percutaneous cannulated cancellous screws, ORIF with buttress plate with or without bone grafting, locking or nonlocking plates, external fixator. As complications we found: redepression 4 case, malunion 2 cases, knee stiffness 9, wound dehiscence in 1 cases and non-union or infection in none of our cases. The average flexion of the injured knee was significantly lower in comparison with the contralateral side (124.9°/135.2°. Knee stability did not differ statistically significantly. There were no signs of posttraumatic arthrosis in 45% of cases, mild signs in 30%, clear signs in 18%, and severe signs in 7%. As conclusion we found that surgical management of tibial plateau fractures will give excellent anatomical reduction and rigid fixation to restore articular congruity, facilitate early motion and reduce arthrosis risk and hence to achieve optimal knee function. The choice of optimal surgical methods, proper approach and implant is made in relation to fracture type according Schatzker and AO classification.

  5. The SEP "robot": a valid virtual reality robotic simulator for the Da Vinci Surgical System?

    Science.gov (United States)

    van der Meijden, O A J; Broeders, I A M J; Schijven, M P

    2010-04-01

    The aim of the study was to determine if the concept of face and construct validity may apply to the SurgicalSim Educational Platform (SEP) "robot" simulator. The SEP robot simulator is a virtual reality (VR) simulator aiming to train users on the Da Vinci Surgical System. To determine the SEP's face validity, two questionnaires were constructed. First, a questionnaire was sent to users of the Da Vinci system (reference group) to determine a focused user-group opinion and their recommendations concerning VR-based training applications for robotic surgery. Next, clinical specialists were requested to complete a pre-tested face validity questionnaire after performing a suturing task on the SEP robot simulator. To determine the SEP's construct validity, outcome parameters of the suturing task were compared, for example, relative to participants' endoscopic experience. Correlations between endoscopic experience and outcome parameters of the performed suturing task were tested for significance. On an ordinal five-point, scale the average score for the quality of the simulator software was 3.4; for its hardware, 3.0. Over 80% agreed that it is important to train surgeons and surgical trainees to use the Da Vinci. There was a significant but marginal difference in tool tip trajectory (p = 0.050) and a nonsignificant difference in total procedure time (p = 0.138) in favor of the experienced group. In conclusion, the results of this study reflect a uniform positive opinion using VR training in robotic surgery. Concepts of face and construct validity of the SEP robotic simulator are present; however, these are not strong and need to be improved before implementation of the SEP robotic simulator in its present state for a validated training curriculum to be successful .

  6. Nuclear regulatory policy concept on safety, security, safeguards and emergency preparedness (3S+EP)

    International Nuclear Information System (INIS)

    Ilyas, Zurias

    2009-01-01

    Regulatory Policy is formulated in regulations that stipulate the assurance of workers and public safety and environmental protection. Legislation and regulations on nuclear energy should consider nuclear safety, security and safeguards, as well as nuclear emergency preparedness (3S+EP) and liability for nuclear damage. Specific requirements stipulated in international conventions and agreements should also be taken into account. Regulatory Policy is formulated in regulations that stipulate the assurance of workers and public safety and environmental protection. Legislation and regulations on nuclear energy should consider nuclear safety, security and safeguards, as well as nuclear emergency preparedness (3S+EP) and liability for nuclear damage. Specific requirements stipulated in international conventions and agreements should also be taken into account. By undertaking proper regulatory oversight on Safety, Security and Emergency Preparedness (3S+EP) as an integrated and comprehensive system, safe and secure use of nuclear energy can be assured. Licence requirements and conditions should fulfil regulatory requirements pertaining to 3S+EP for nuclear installation as an integrated system. An effective emergency capacity that can be immediately mobilized is important. The capacity in protecting the personnel before, during and after the disaster should also be planned. Thus, proper emergency preparedness should be supported by adequate resources. The interface between safety, security, safeguards and emergency preparedness has to be set forth in nuclear regulations, such as regulatory requirements; 3S+EP; components, systems and structures of nuclear installations and human resources. Licensing regulations should stipulate, among others, DIQ, installations security system, safety analysis report, emergency preparedness requirements and necessary human resources that meet the 3S+EP requirements.

  7. Age variations in the properties of human tibial trabecular bone and cartilage

    DEFF Research Database (Denmark)

    Ding, Ming

    2000-01-01

    , such as apparent, apparent ash and collagen densities of human tibial trabecular bone have significant relationships with age. Tissue density and mineral concentration remain constant throughout life. Trabecular bone is tougher in the younger age, i.e. fracture requires more energy. Collagen density was the single......Initiated and motivated by clinical and scientific problems such as age-related bone fracture, prosthetic loosening, bone remodeling, and degenerative bone diseases, much significant research on the properties of trabecular bone has been carried out over the last two decades. This work has mainly...... focused on the central vertebral trabecular bone, while little is known about age-related changes in the properties of human peripheral (tibial) trabecular bone. Knowledge of the properties of peripheral (tibial) trabecular bone is of major importance for the understanding of degenerative diseases...

  8. VAC Therapy Direct to the Medullary Cavity for Chronic Tibial Osteomyelitis.

    Science.gov (United States)

    Miyamura, Satoshi; Tsuji, Shigeyoshi; Iwai, Takao; Hamada, Masayuki

    2016-06-01

    Vacuum-assisted wound closure (VAC) is useful for difficult wound beds, although sites where bleeding or infection is expected are usually regarded as problematic for this therapy. This report outlines the treatment of chronic tibial osteomyelitis (Cierny- Mader type III) due to mixed infection with Nocardia spp and Bacteroi- des fragilis by postoperative VAC therapy direct to the medullary cavity, followed by wound coverage with a gastrocnemius myocutaneous skin flap. A 64-year-old man developed chronic left tibial os- teomyelitis after a work injury. The nonviable tissues were debrided, including a sequestrum. Nocardia spp and B. fragilis were isolated from surgical bone specimens, and chronic tibial osteomyelitis due to mixed infection was diagnosed. Postoperatively, VAC therapy was performed directly to the open medullary cavity of the tibia and sub- sequently covered the residual soft tissue defect with a gastrocnemius myocutaneous flap. The authors could not find any English literature on VAC therapy direct to the medullary cavity combined with transplantation of a myocutaneous flap for osteomyelitis. Nocardia spp can cause a variety of infections, among which osteomyelitis occupies a relatively small percentage. This case raises the possibil- ity of treating chronic tibial osteomyelitis caused by mixed infection with Nocardia spp and B. fragilis by applying postoperative VAC ther- apy directly to the medullary cavity and covering the residual wound with a gastrocnemius myocutaneous flap.

  9. Shock Geometry and Spectral Breaks in Large SEP Events

    Science.gov (United States)

    Li, G.; Zank, G. P.; Verkhoglyadova, Olga; Mewaldt, R. A.; Cohen, C. M. S.; Mason, G. M.; Desai, M. I.

    2009-09-01

    Solar energetic particle (SEP) events are traditionally classified as "impulsive" or "gradual." It is now widely accepted that in gradual SEP events, particles are accelerated at coronal mass ejection-driven (CME-driven) shocks. In many of these large SEP events, particle spectra exhibit double power law or exponential rollover features, with the break energy or rollover energy ordered as (Q/A)α, with Q being the ion charge in e and A the ion mass in units of proton mass mp . This Q/A dependence of the spectral breaks provides an opportunity to study the underlying acceleration mechanism. In this paper, we examine how the Q/A dependence may depend on shock geometry. Using the nonlinear guiding center theory, we show that α ~ 1/5 for a quasi-perpendicular shock. Such a weak Q/A dependence is in contrast to the quasi-parallel shock case where α can reach 2. This difference in α reflects the difference of the underlying parallel and perpendicular diffusion coefficients κ|| and κbottom. We also examine the Q/A dependence of the break energy for the most general oblique shock case. Our analysis offers a possible way to remotely examine the geometry of a CME-driven shock when it is close to the Sun, where the acceleration of particle to high energies occurs.

  10. Sensory and motor neuropathy in a Border Collie.

    Science.gov (United States)

    Harkin, Kenneth R; Cash, Walter C; Shelton, G Diane

    2005-10-15

    A 5-month-old female Border Collie was evaluated because of progressive hind limb ataxia. The predominant clinical findings suggested a sensory neuropathy. Sensory nerve conduction velocity was absent in the tibial, common peroneal, and radial nerves and was decreased in the ulnar nerve; motor nerve conduction velocity was decreased in the tibial, common peroneal, and ulnar nerves. Histologic examination of nerve biopsy specimens revealed considerable nerve fiber depletion; some tissue sections had myelin ovoids, foamy macrophages, and axonal degeneration in remaining fibers. Marked depletion of most myelinated fibers within the peroneal nerve (a mixed sensory and motor nerve) supported the electrodiagnostic findings indicative of sensorimotor neuropathy. Progressive deterioration in motor function occurred over the following 19 months until the dog was euthanatized. A hereditary link was not established, but a littermate was similarly affected. The hereditary characteristic of this disease requires further investigation.

  11. The effect of posterior tibial slope on simulated laxity tests in cruciate-retaining TKA

    NARCIS (Netherlands)

    Marra, Marco A.; Strzelczak, Marta; Heesterbeek, Petra J.C.; van de Groes, Sebastiaan; Janssen, Dennis; Koopman, Bart F.J.M.; Wymenga, Ate B.; Verdonschot, Nico

    2017-01-01

    INTRODUCTION: Tibial slope can affect the outcomes of Total Knee Arthroplasty (TKA). More posterior slope potentially helps releasing a too tight flexion gap and it is generally associated with a wider range of post-operative knee flexion. However, the mechanism by which tibial slope affects the

  12. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  13. [Operative treatment for complex tibial plateau fractures].

    Science.gov (United States)

    Song, Qi-Zhi; Li, Tao

    2012-03-01

    To explore the surgical methods and clinical evaluation of complex tibial plateau fractures resulted from high-energy injuries. From March 2006 to May 2009,48 cases with complex tibial plateau fractures were treated with open reduction and plate fixation, including 37 males and 11 females, with an average age of 37 years (ranged from 18 to 63 years). According to Schatzker classification, 16 cases were type IV, 20 cases type V and 12 cases type VI. All patients were examined by X-ray flim and CT scan. The function of knee joint were evaluated according to postoperative follow-up X-ray and Knee Merchant Rating. Forty-eight patients were followed up with a mean time of 14 months. According to Knee Merchant Rating, 24 cases got excellent results, 16 cases good, 6 cases fair and 2 cases poor. Appropriate operation time, anatomical reduction, suitable bone graft and reasonable rehabilitation exercises can maximally recovery the function of knee joint.

  14. Traumatic Dislodgement of Tibial Polyethylene Insert after a High-Flex Posterior-Stabilized Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Juan Felix Astoul Bonorino

    2015-01-01

    Full Text Available Many pathologic entities can produce a painful total knee replacement (TKR that may lead to potential prosthetic failure. Polyethylene insert dissociation from the tibial baseplate has been described most frequently after mobile-bearing and cruciate-retaining TKRs. However, only 3 tibial insert dislocations in primary fixed-bearing High-Flex posterior-stabilized TKRs have been reported. We present a new case of tibial insert dislocation in a High-Flex model that shares similarities and differences with the cases reported, facilitating the analysis of the potential causes, which still remain undefined.

  15. [Tibial plateau fractures in winter sports. Current treatment options].

    Science.gov (United States)

    Zimmermann, V

    2014-01-01

    Tibial plateau fractures overall and especially in winter sports are rare. However, the incidence in recent years is increasing. In a retrospective study from 2009-2012, we found 52 injuries affiliated with winter sports. Noticeable was the high rate of severe injury patterns. In 20 of the 52 cases, there were complete articular or bicondylar fractures (38 %). In 25 cases (48 %), fragment dislocation corresponding to the Moore classification was observed. The operative algorithm was based on the initial soft tissue damage and the type of fracture. A two or more stage procedure with first line soft tissue management and temporary external fixation stabilization was performed 12 times. The final internal osteosynthesis was based on the morphology of the fracture, i.e., direct exposition and stabilization of relevant fracture patterns. In 24 cases (46 %), there was a need for two (or more) approaches. In the anterior aspect of the tibial head, customary implants were used; posterior pathologies were stabilized with low-dimension implants. Summarizing with regard to the literature, there is a more discriminating view of tibial plateau fractures, regarding all relevant fracture patterns. Thus, different options in operative access and choice of implants can be made.

  16. Section modulus is the optimum geometric predictor for stress fractures and medial tibial stress syndrome in both male and female athletes.

    Science.gov (United States)

    Franklyn, Melanie; Oakes, Barry; Field, Bruce; Wells, Peter; Morgan, David

    2008-06-01

    Various tibial dimensions and geometric parameters have been linked to stress fractures in athletes and military recruits, but many mechanical parameters have still not been investigated. Sedentary people, athletes with medial tibial stress syndrome, and athletes with stress fractures have smaller tibial geometric dimensions and parameters than do uninjured athletes. Cohort study; Level of evidence, 3. Using a total of 88 subjects, male and female patients with either a tibial stress fracture or medial tibial stress syndrome were compared with both uninjured aerobically active controls and uninjured sedentary controls. Tibial scout radiographs and cross-sectional computed tomography images of all subjects were scanned at the junction of the midthird and distal third of the tibia. Tibial dimensions were measured directly from the films; other parameters were calculated numerically. Uninjured exercising men have a greater tibial cortical cross-sectional area than do their sedentary and injured counterparts, resulting in a greater value of some other cross-sectional geometric parameters, particularly the section modulus. However, for women, the cross-sectional areas are either not different or only marginally different, and there are few tibial dimensions or geometric parameters that distinguish the uninjured exercisers from the sedentary and injured subjects. In women, the main difference between the groups was the distribution of cortical bone about the centroid as a result of the different values of section modulus. Last, medial tibial stress syndrome subjects had smaller tibial cross-sectional dimensions than did their uninjured exercising counterparts, suggesting that medial tibial stress syndrome is not just a soft-tissue injury but also a bony injury. The results show that in men, the cross-sectional area and the section modulus are the key parameters in the tibia to distinguish exercise and injury status, whereas for women, it is the section modulus only.

  17. 29 CFR 2520.104-48 - Alternative method of compliance for model simplified employee pensions-IRS Form 5305-SEP.

    Science.gov (United States)

    2010-07-01

    ... employee pensions-IRS Form 5305-SEP. 2520.104-48 Section 2520.104-48 Labor Regulations Relating to Labor... compliance for model simplified employee pensions—IRS Form 5305-SEP. Under the authority of section 110 of... Security Act of 1974 in the case of a simplified employee pension (SEP) described in section 408(k) of the...

  18. Nerve Blocks

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Nerve Blocks A nerve block is an injection to ... the limitations of Nerve Block? What is a Nerve Block? A nerve block is an anesthetic and/ ...

  19. Double muscle innervation using end-to-side neurorrhaphy in rats Dupla inervação muscular com neurorrafia término-lateral em ratos

    Directory of Open Access Journals (Sweden)

    Elisangela Jeronymo Stipp-Brambilla

    2012-01-01

    Full Text Available CONTEXT AND OBJECTIVE: One of the techniques used for treating facial paralysis is double muscle innervation using end-to-end neurorrhaphy with sectioning of healthy nerves. The aim of this study was to evaluate whether double muscle innervation by means of end-to-side neurorrhaphy could occur, with maintenance of muscle innervation. DESIGN AND SETTING: Experimental study developed at the Experimental Research Center, Faculdade de Medicina de Botucatu, Unesp. METHODS: One hundred rats were allocated to five groups as follows: G1, control group; G2, the peroneal nerve was sectioned; G3, the tibial nerve was transected and the proximal stump was end-to-side sutured to the intact peroneal nerve; G4, 120 days after the G3 surgery, the peroneal nerve was sectioned proximally to the neurorrhaphy; G5, 120 days after the G3 surgery, the peroneal and tibial nerves were sectioned proximally to the neurorrhaphy. RESULTS: One hundred and fifty days after the surgery, G3 did not show any change in tibial muscle weight or muscle fiber diameter, but the axonal fiber diameter in the peroneal nerve distal to the neurorrhaphy had decreased. Although G4 showed atrophy of the cranial tibial muscle 30 days after sectioning the peroneal nerve, the electrophysiological test results and axonal diameter measurement confirmed that muscle reinnervation had occurred. CONCLUSION: These findings suggest that double muscle innervation did not occur through end-to-side neurorrhaphy; the tibial nerve was not able to maintain muscle innervation after the peroneal nerve had been sectioned, although muscle reinnervation was found to have occurred, 30 days after the peroneal nerve had been sectioned.CONTEXTO E OBJETIVO: Uma das técnicas utilizadas para tratamento da paralisia facial é a dupla inervação muscular com neurorrafia término-terminal, seccionando-se nervos sadios. O objetivo deste trabalho foi avaliar a ocorrência de dupla inervação muscular através de

  20. [The geometry of the keel determines the behaviour of the tibial tray against torsional forces in total knee replacement].

    Science.gov (United States)

    García David, S; Cortijo Martínez, J A; Navarro Bermúdez, I; Maculé, F; Hinarejos, P; Puig-Verdié, L; Monllau, J C; Hernández Hermoso, J A

    2014-01-01

    The keel design of the tibial tray is essential for the transmission of the majority of the forces to the peripheral bone structures, which have better mechanical proprieties, thus reducing the risk of loosening. The aim of the present study was to compare the behaviour of different tibial tray designs submitted to torsional forces. Four different tibial components were modelled. The 3-D reconstruction was made using the Mimics software. The solid elements were generated by SolidWorks. The finite elements study was done by Unigraphics. A torsional force of 6 Nm. applied to the lateral aspects of each tibial tray was simulated. The GENUTECH® tibial tray, with peripheral trabecular bone support, showed a lower displacement and less transmitted tensions under torsional forces. The results suggest that a tibial tray with more peripheral support behaves mechanically better than the other studied designs. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  1. Asymmetry in gait pattern following tibial shaft fractures

    DEFF Research Database (Denmark)

    Larsen, Peter; Læssøe, Uffe; Rasmussen, Sten

    2017-01-01

    INTRODUCTION: Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12...... months post-operatively following intramedullary nailing of a tibial shaft fracture are different compared with a healthy reference population. PATIENTS AND METHODS: The study design was a prospective cohort study. The primary outcome measurement was the gait patterns at 6 and 12 months post......-operatively measured with a 6-metre-long pressure-sensitive mat. The mat registers footprints and present gait speed, cadence as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. RESULTS: 49 patients were included with a mean age of 43.1 years (18...

  2. On the Onset Frequency of Metric Type II Radio Bursts and the Longitudinal Extent of the Associated SEP Events

    Science.gov (United States)

    Makela, P. A.; Gopalswamy, N.; Yashiro, S.; Thakur, N.; Akiyama, S.; Xie, H.

    2017-12-01

    In a recent study Gopalswamy et al. (2017, J. Phys. Conf. Ser., Proc. 16th AIAC) found that the ground level enhancements (GLEs), regular solar energetic particle (SEP) events and filament eruption (FE) associated SEP events have distinct average starting frequencies of the associated type II bursts, although the distributions overlap. They also found that the initial acceleration of the coronal mass ejections (CMEs) associated with the three groups were distinct. Based on these earlier results emphasizing a hierarchical relationship of CME kinematics and SEP events, we studied the possible dependence between the longitudinal spread of the SEP events and the onset frequency of metric type II. The studied >25 MeV SEP events are from the list of Richardson et al. (2014, Sol. Phys. 289) covering the first seven years of the STEREO mission. However, our preliminary results show only a weak correlation between the extent of the SEP event and the onset frequency of the metric type II radio burst.

  3. Reconstruction of bilateral tibial aplasia and split hand-foot syndrome in a father and daughter.

    Science.gov (United States)

    Al Kaissi, Ali; Ganger, Rudolf; Klaushofer, Klaus; Grill, Franz

    2014-01-01

    Tibial aplasia is of heterogeneous aetiology, the majority of reports are sporadic. We describe the reconstruction procedures in two subjects - a daughter and father manifested autosomal dominant (AD) inheritance of the bilateral tibial aplasia and split hand-foot syndrome. Reconstruction of these patients required multiple surgical procedures and orthoprosthesis was mandatory. The main goal of treatment was to achieve walking. Stabilization of the ankle joint by fibular-talar-chondrodesis on both sides, followed by bilateral Brown-procedure at the knee joint level has been applied accordingly. The outcome was with improved function of the deformed limbs and walking was achieved with simultaneous designation of orthotic fitting. This is the first study encompassing the diagnosis and management of a father and daughter with bilateral tibial aplasia associated with variable split hand/foot deformity without foot ablation. Our patients showed the typical AD pattern of inheritance of split-hand/foot and tibial aplasia.

  4. Catalytic mechanism of Sep-tRNA:Cys-tRNA synthase: sulfur transfer is mediated by disulfide and persulfide.

    Science.gov (United States)

    Liu, Yuchen; Dos Santos, Patricia C; Zhu, Xiang; Orlando, Ron; Dean, Dennis R; Söll, Dieter; Yuan, Jing

    2012-02-17

    Sep-tRNA:Cys-tRNA synthase (SepCysS) catalyzes the sulfhydrylation of tRNA-bound O-phosphoserine (Sep) to form cysteinyl-tRNA(Cys) (Cys-tRNA(Cys)) in methanogens that lack the canonical cysteinyl-tRNA synthetase (CysRS). A crystal structure of the Archaeoglobus fulgidus SepCysS apoenzyme provides information on the binding of the pyridoxal phosphate cofactor as well as on amino acid residues that may be involved in substrate binding. However, the mechanism of sulfur transfer to form cysteine was not known. Using an in vivo Escherichia coli complementation assay, we showed that all three highly conserved Cys residues in SepCysS (Cys(64), Cys(67), and Cys(272) in the Methanocaldococcus jannaschii enzyme) are essential for the sulfhydrylation reaction in vivo. Biochemical and mass spectrometric analysis demonstrated that Cys(64) and Cys(67) form a disulfide linkage and carry a sulfane sulfur in a portion of the enzyme. These results suggest that a persulfide group (containing a sulfane sulfur) is the proximal sulfur donor for cysteine biosynthesis. The presence of Cys(272) increased the amount of sulfane sulfur in SepCysS by 3-fold, suggesting that this Cys residue facilitates the generation of the persulfide group. Based upon these findings, we propose for SepCysS a sulfur relay mechanism that recruits both disulfide and persulfide intermediates.

  5. AJNT volume 5 issue 3 [Sep 2012].indd

    African Journals Online (AJOL)

    159. Arab Journal of Nephrology and Transplantation. Arab Journal of Nephrology and Transplantation. 2012 Sep;5(3):159-61. Case report. AJNT. Abstract. Introduction: The Saharan horned viper (Cerastes cerastes) is a common snake in the sandy and rocky regions in the south of Morocco. Although nearly all snakes with.

  6. Specific paucity of unmyelinated C-fibers in cutaneous peripheral nerves of the African naked-mole rat: comparative analysis using six species of Bathyergidae.

    Science.gov (United States)

    St John Smith, Ewan; Purfürst, Bettina; Grigoryan, Tamara; Park, Thomas J; Bennett, Nigel C; Lewin, Gary R

    2012-08-15

    In mammalian peripheral nerves, unmyelinated C-fibers usually outnumber myelinated A-fibers. By using transmission electron microscopy, we recently showed that the saphenous nerve of the naked mole-rat (Heterocephalus glaber) has a C-fiber deficit manifested as a substantially lower C:A-fiber ratio compared with other mammals. Here we determined the uniqueness of this C-fiber deficit by performing a quantitative anatomical analysis of several peripheral nerves in five further members of the Bathyergidae mole-rat family: silvery (Heliophobius argenteocinereus), giant (Fukomys mechowii), Damaraland (Fukomys damarensis), Mashona (Fukomys darlingi), and Natal (Cryptomys hottentotus natalensis) mole-rats. In the largely cutaneous saphenous and sural nerves, the naked mole-rat had the lowest C:A-fiber ratio (∼1.5:1 compared with ∼3:1), whereas, in nerves innervating both skin and muscle (common peroneal and tibial) or just muscle (lateral/medial gastrocnemius), this pattern was mostly absent. We asked whether lack of hair follicles alone accounts for the C-fiber paucity by using as a model a mouse that loses virtually all its hair as a consequence of conditional deletion of the β-catenin gene in the skin. These β-catenin loss-of function mice (β-cat LOF mice) displayed only a mild decrease in C:A-fiber ratio compared with wild-type mice (4.42 compared with 3.81). We suggest that the selective cutaneous C-fiber deficit in the cutaneous nerves of naked mole-rats is unlikely to be due primarily to lack of skin hair follicles. Possible mechanisms contributing to this unique peripheral nerve anatomy are discussed. Copyright © 2012 Wiley Periodicals, Inc.

  7. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  8. Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee

    LENUS (Irish Health Repository)

    Cashman, James P

    2011-08-20

    Abstract Background Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. Method A comparison of intramedullary versus extramedullary alignment jig was performed. Radiological alignment of tibial components and patient outcomes of 103 Triathlon total knee arthroplasties were analysed. Results Use of the intramedullary was found to be significantly more accurate in determining coronal alignment (p = 0.02) while use of the extramedullary jig was found to give more accurate results in sagittal alignment (p = 0.04). There was no significant difference in WOMAC or SF-36 at six months. Conclusion Use of an intramedullary jig is preferable for positioning of the tibial component using this knee system.

  9. Negative pressure wound therapy for Gustilo Anderson grade IIIb open tibial fractures.

    Science.gov (United States)

    Park, Chul Hyun; Shon, Oog Jin; Kim, Gi Beom

    2016-09-01

    Traditionally, Gustilo Anderson grade IIIb open tibial fractures have been treated by initial wide wound debridement, stabilization of fracture with external fixation, and delayed wound closure. The purpose of this study is to evaluate the clinical and radiological results of staged treatment using negative pressure wound therapy (NPWT) for Gustilo Anderson grade IIIb open tibial fractures. 15 patients with Gustilo Anderson grade IIIb open tibial fractures, treated using staged protocol by a single surgeon between January 2007 and December 2011 were reviewed in this retrospective study. The clinical results were assessed using a Puno scoring system for severe open fractures of the tibia at the last followup. The range of motion (ROM) of the knee and ankle joints and postoperative complication were evaluated at the last followup. The radiographic results were assessed using time to bone union, coronal and sagittal angulations and a shortening at the last followup. The mean score of Puno scoring system was 87.4 (range 67-94). The mean ROM of the knee and ankle joints was 121.3° (range 90°-130°) and 37.7° (range 15°-50°), respectively. Bone union developed in all patients and the mean time to union was 25.3 weeks (range 16-42 weeks). The mean coronal angulation was 2.1° (range 0-4°) and sagittal was 2.7° (range 1-4°). The mean shortening was 4.1 mm (range 0-8 mm). Three patients had partial flap necrosis and 1 patient had total flap necrosis. There was no superficial and deep wound infection. Staged treatment using NPWT decreased the risks of infection and requirement of flap surgeries in Gustilo Anderson grade IIIb open tibial fractures. Therefore, staged treatment using NPWT could be a useful treatment option for Gustilo Anderson grade IIIb open tibial fractures.

  10. Acellular Nerve Allografts in Peripheral Nerve Regeneration: A Comparative Study

    Science.gov (United States)

    Moore, Amy M.; MacEwan, Matthew; Santosa, Katherine B.; Chenard, Kristofer E.; Ray, Wilson Z.; Hunter, Daniel A.; Mackinnon, Susan E.; Johnson, Philip J.

    2011-01-01

    Background Processed nerve allografts offer a promising alternative to nerve autografts in the surgical management of peripheral nerve injuries where short deficits exist. Methods Three established models of acellular nerve allograft (cold-preserved, detergent-processed, and AxoGen® -processed nerve allografts) were compared to nerve isografts and silicone nerve guidance conduits in a 14 mm rat sciatic nerve defect. Results All acellular nerve grafts were superior to silicone nerve conduits in support of nerve regeneration. Detergent-processed allografts were similar to isografts at 6 weeks post-operatively, while AxoGen®-processed and cold-preserved allografts supported significantly fewer regenerating nerve fibers. Measurement of muscle force confirmed that detergent-processed allografts promoted isograft-equivalent levels of motor recovery 16 weeks post-operatively. All acellular allografts promoted greater amounts of motor recovery compared to silicone conduits. Conclusions These findings provide evidence that differential processing for removal of cellular constituents in preparing acellular nerve allografts affects recovery in vivo. PMID:21660979

  11. Reconstruction of bilateral tibial aplasia and split hand-foot syndrome in a father and daughter

    Directory of Open Access Journals (Sweden)

    Ali Al Kaissi

    2014-01-01

    Full Text Available Background: Tibial aplasia is of heterogeneous aetiology, the majority of reports are sporadic. We describe the reconstruction procedures in two subjects - a daughter and father manifested autosomal dominant (AD inheritance of the bilateral tibial aplasia and split hand-foot syndrome. Materials and Methods: Reconstruction of these patients required multiple surgical procedures and orthoprosthesis was mandatory. The main goal of treatment was to achieve walking. Stabilization of the ankle joint by fibular-talar-chondrodesis on both sides, followed by bilateral Brown-procedure at the knee joint level has been applied accordingly. Results: The outcome was with improved function of the deformed limbs and walking was achieved with simultaneous designation of orthotic fitting. Conclusion: This is the first study encompassing the diagnosis and management of a father and daughter with bilateral tibial aplasia associated with variable split hand/foot deformity without foot ablation. Our patients showed the typical AD pattern of inheritance of split-hand/foot and tibial aplasia.

  12. 77 FR 5026 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-02-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... SEP: Occupational Safety and Health Education and Research Centers, PAR 10-217. Contact Person For...

  13. The Quebec connection : though based in Canada, all of ProSep's sales are foreign

    International Nuclear Information System (INIS)

    Anon.

    2010-01-01

    Montreal-based ProSep Inc. developed a method for stripping hydrocarbons from water. The potential uses for the technology include oil spill cleanups and cleaning bilge water and industrial wash water. Seven years ago, ProSep targeted the Alberta oilsands and the North Sea markets with its technology because water produced with bitumen from steam assisted gravity drainage wells had to be purified before going back into the steam boilers for re-injection, and new regulations in the North Sea were requiring operators to reduce hydrocarbon discharges into the ocean. Upon selling a few units to large companies operating in the North Sea, ProSep sold several units to a large national oil company in the Middle East. As stock spiked in 2006, the company raised substantial capital and acquired Pure Group AS of Stavanger, Norway, in 2007. Pure Group's leading technology for oil, gas and water treatment is called the CTour, which mixes condensate with produced water to improve coalescence of dispersed and dissolved oil droplets. In the Middle East, Aramco has successfully tested ProSep's ProSalt system as a means of saving millions of gallons of wash water per year. Also in the Middle East, ProSep sold a TORR unit as part of a package to Al-Rashed Company, a leading contractor in Kuwait. The contract was to supply a complete crude oil processing train for separation, dehydration and desalting at Kuwait Oil Company's Ratqa and Abdali facility in northern Kuwait. The TORR is designed to remove dispersed hydrocarbons from produced water without the use of chemicals. 2 figs.

  14. Medial tibial stress syndrome: a critical review.

    Science.gov (United States)

    Moen, Maarten H; Tol, Johannes L; Weir, Adam; Steunebrink, Miriam; De Winter, Theodorus C

    2009-01-01

    Medial tibial stress syndrome (MTSS) is one of the most common leg injuries in athletes and soldiers. The incidence of MTSS is reported as being between 4% and 35% in military personnel and athletes. The name given to this condition refers to pain on the posteromedial tibial border during exercise, with pain on palpation of the tibia over a length of at least 5 cm. Histological studies fail to provide evidence that MTSS is caused by periostitis as a result of traction. It is caused by bony resorption that outpaces bone formation of the tibial cortex. Evidence for this overloaded adaptation of the cortex is found in several studies describing MTSS findings on bone scan, magnetic resonance imaging (MRI), high-resolution computed tomography (CT) scan and dual energy x-ray absorptiometry. The diagnosis is made based on physical examination, although only one study has been conducted on this subject. Additional imaging such as bone, CT and MRI scans has been well studied but is of limited value. The prevalence of abnormal findings in asymptomatic subjects means that results should be interpreted with caution. Excessive pronation of the foot while standing and female sex were found to be intrinsic risk factors in multiple prospective studies. Other intrinsic risk factors found in single prospective studies are higher body mass index, greater internal and external ranges of hip motion, and calf girth. Previous history of MTSS was shown to be an extrinsic risk factor. The treatment of MTSS has been examined in three randomized controlled studies. In these studies rest is equal to any intervention. The use of neoprene or semi-rigid orthotics may help prevent MTSS, as evidenced by two large prospective studies.

  15. Some Statistical Properties of the Decay Phase of SEP-Events

    National Research Council Canada - National Science Library

    Kechskemety, K

    2003-01-01

    ... (SEP) events. The shape of the particle flux decline is of particular importance: power-law time dependence indicates the dominance of diffusive propagation, whereas exponential-law, decline emphasizes adiabatic deceleration and convection...

  16. The effect of retained intramedullary nails on tibial bone mineral density.

    Science.gov (United States)

    Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A

    2008-07-01

    Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.

  17. Manual therapy in joint and nerve structures combined with exercises in the treatment of recurrent ankle sprains: A randomized, controlled trial.

    Science.gov (United States)

    Plaza-Manzano, Gustavo; Vergara-Vila, Marta; Val-Otero, Sandra; Rivera-Prieto, Cristina; Pecos-Martin, Daniel; Gallego-Izquierdo, Tomás; Ferragut-Garcías, Alejandro; Romero-Franco, Natalia

    2016-12-01

    Recurrent ankle sprains often involve residual symptoms for which subjects often perform proprioceptive or/and strengthening exercises. However, the effectiveness of mobilization to influence important nerve structures due to its anatomical distribution like tibial and peroneal nerves is unclear. To analyze the effects of proprioceptive/strengthening exercises versus the same exercises and manual therapy including mobilizations to influence joint and nerve structures in the management of recurrent ankle sprains. A randomized single-blind controlled clinical trial. Fifty-six patients with recurrent ankle sprains and regular sports practice were randomly assigned to experimental or control group. The control group performed 4 weeks of proprioceptive/strengthening exercises; the experimental group performed 4 weeks of the same exercises combined with manual therapy (mobilizations to influence joint and nerve structures). Pain, self-reported functional ankle instability, pressure pain threshold (PPT), ankle muscle strength, and active range of motion (ROM) were evaluated in the ankle joint before, just after and one month after the interventions. The within-group differences revealed improvements in all of the variables in both groups throughout the time. Between-group differences revealed that the experimental group exhibited lower pain levels and self-reported functional ankle instability and higher PPT, ankle muscle strength and ROM values compared to the control group immediately after the interventions and one month later. A protocol involving proprioceptive and strengthening exercises and manual therapy (mobilizations to influence joint and nerve structures) resulted in greater improvements in pain, self-reported functional joint stability, strength and ROM compared to exercises alone. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Surgical treatment of refractory tibial stress fractures in elite dancers: a case series.

    Science.gov (United States)

    Miyamoto, Ryan G; Dhotar, Herman S; Rose, Donald J; Egol, Kenneth

    2009-06-01

    Treatment of tibial stress fractures in elite dancers is centered on rest and activity modification. Surgical intervention in refractory cases has important implications affecting the dancers' careers. Refractory tibial stress fractures in dancers can be treated successfully with drilling and bone grafting or intramedullary nailing. Case series; Level of evidence, 4. Between 1992 and 2006, 1757 dancers were evaluated at a dance medicine clinic; 24 dancers (1.4%) had 31 tibial stress fractures. Of that subset, 7 (29.2%) elite dancers with 8 tibial stress fractures were treated operatively with either intramedullary nailing or drilling and bone grafting. Six of the patients were followed up closely until they were able to return to dance. One patient was available only for follow-up phone interview. Data concerning their preoperative treatment regimens, operative procedures, clinical union, radiographic union, and time until return to dance were recorded and analyzed. The mean age of the surgical patients at the time of stress fracture was 22.6 years. The mean duration of preoperative symptoms before surgical intervention was 25.8 months. Four of the dancers were male and 3 were female. All had failed nonoperative treatment regimens. Five patients (5 tibias) underwent drilling and bone grafting of the lesion, and 2 patients (3 tibias) with completed fractures or multiple refractory stress fractures underwent intramedullary nailing. Clinical union was achieved at a mean of 6 weeks and radiographic union at 5.1 months. Return to full dance activity was at an average of 6.5 months postoperatively. Surgical intervention for tibial stress fractures in dancers who have not responded to nonoperative management allowed for resolution of symptoms and return to dancing with minimal morbidity.

  19. Dependence of large SEP events with different energies on the associated flares and CMEs

    Science.gov (United States)

    Le, Gui-Ming; Zhang, Xue-Feng

    2017-12-01

    To investigate the dependence of large gradual solar energetic particle (SEP) events on the associated flares and coronal mass ejections (CMEs), the correlation coefficients (CCs) between peak intensities of E> 10 {MeV} (I 10), E> 30 {MeV} (I 30) and E> 50 {MeV} (I 50) protons and soft X-ray (SXR) emission of associated flares and the speeds of associated CMEs in the three longitudinal areas W0-W39, W40-W70 (hereafter the well connected region) and W71-W90 have been calculated. Classical correlation analysis shows that CCs between SXR emission and peak intensities of SEP events always reach their largest value in the well connected region and then decline dramatically in the longitudinal area outside the well connected region, suggesting that they may contribute to the production of SEPs in large SEP events. Both classical and partial correlation analyses show that SXR fluence is a better parameter describing the relationship between flares and SEP events. For large SEP events with source location in the well connected region, the CCs between SXR fluence and I 10, I 30 and I 50 are 0.58±0.12, 0.80±0.06 and 0.83±0.06 respectively, while the CCs between CME speed and I 10, I 30 and I 50 are 0.56±0.12, 0.52±0.13 and 0.48±0.13 respectively. The partial correlation analyses show that in the well connected region, both CME shock and SXR fluence can significantly affect I 10, but SXR peak flux makes no additional contribution. For E> 30 {MeV} protons with source location in the well connected region, only SXR fluence can significantly affect I 30, and the CME shock makes a small contribution to I 30, but SXR peak flux makes no additional contribution. For E> 50 {MeV} protons with source location in the well connected region, only SXR fluence can significantly affect I 50, but both CME shock and SXR peak flux make no additional contribution. We conclude that these findings provide statistical evidence that for SEP events with source locations in the well connected

  20. Nerve conduction and excitability studies in peripheral nerve disorders

    DEFF Research Database (Denmark)

    Krarup, Christian; Moldovan, Mihai

    2009-01-01

    counterparts in the peripheral nervous system, in some instances without peripheral nervous system symptoms. Both hereditary and acquired demyelinating neuropathies have been studied and the effects on nerve pathophysiology have been compared with degeneration and regeneration of axons. SUMMARY: Excitability......PURPOSE OF REVIEW: The review is aimed at providing information about the role of nerve excitability studies in peripheral nerve disorders. It has been known for many years that the insight into peripheral nerve pathophysiology provided by conventional nerve conduction studies is limited. Nerve...... excitability studies are relatively novel but are acquiring an increasingly important role in the study of peripheral nerves. RECENT FINDINGS: By measuring responses in nerve that are related to nodal function (strength-duration time constant, rheobase and recovery cycle) and internodal function (threshold...

  1. 78 FR 66938 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-11-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review Notice of..., Number 181, Page 57391). This SEP, scheduled to convene on November 12-15, 2013, is canceled. Notice will...

  2. 78 FR 66937 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-11-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review Notice of... Volume 78, Number 191, Page 60877). This SEP, scheduled to convene on November 6, 2013, is canceled...

  3. 78 FR 23768 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-04-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... Centers for Disease Control and Prevention (CDC) announces the aforementioned SEP: Time and Date: 1:00 p.m...

  4. Biomechanical Factors in Tibial Stress Fracture

    Science.gov (United States)

    2001-08-01

    Relationship between Loading Rates and Tibial Accelerometry in Forefoot Strike Runners. Presented at the Annual American Society of Biomechanics Mtg...of the APTA, Seattle, WA, 2/99. McClay, IS, Williams, DS, and Manal, KT. Lower Extremity Mechanics of Runners with a Converted Forefoot Strike ...Management, Inc, 1998-1999 The Effect of Different Orthotic Devices on Lower Extremity Mechanics of Rearfoot and Forefoot Strikers, $3,500. Foot Management

  5. Anterior Tibial Artery Pseudoaneurysm: Case Report

    Directory of Open Access Journals (Sweden)

    Funda Tor

    2012-06-01

    Full Text Available The aneurysmsatic changes of the infrapopliteal arteries are rarely seen. They are pseudoaneurysms rather than true aneursyms. The most important cause of them is trauma. There is not a standart treatment for infrapopliteal aneursyms. In this study, we have evaluated a case operated for anterior tibial artery pseudoaneurysm developed after penetrant trauma and diagnosed two weeks later. [Cukurova Med J 2012; 37(3.000: 172-175

  6. MR evaluation of femoral neck version and tibial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, James Karl; Dwek, Jerry R. [University of California, San Diego, Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Pring, Maya E. [Rady Children' s Hospital, Department of Pediatric Orthopedic Surgery, San Diego, CA (United States)

    2012-01-15

    Abnormalities of femoral neck version have been associated with a number of hip abnormalities in children, including slipped capital femoral epiphysis, proximal femoral focal deficiency, coxa vara, a deep acetabulum and, rarely, developmental dysplasia of the hip. Orthopedic surgeons also are interested in quantifying the femoral neck anteversion or retroversion in children especially to plan derotational osteotomies. Historically, the angle of femoral version and tibial torsion has been measured with the use of radiography and later by CT. Both methods carry with them the risks associated with ionizing radiation. Techniques that utilize MR are used less often because of the associated lengthy imaging times. This article describes a technique using MRI to determine femoral neck version and tibial torsion with total scan times of approximately 10 min. (orig.)

  7. Adult tibial intercondylar eminence fracture: evaluation with MR imaging

    International Nuclear Information System (INIS)

    Toye, Leon R.; Cummings, Dean P.; Armendariz, Gus

    2002-01-01

    Tibial intercondylar eminence (TIE) fractures are well described in the pediatric orthopedic literature. Adult TIEs are much less common, and limited literature exists on the subject. Adult knee hyperextension injuries commonly result in anterior cruciate ligament (ACL) injury; however, with significant trauma, a TIE enters the differential diagnosis. Identification and classification of TIE fractures typically has been provided by radiography. The incidence of concomitant injuries with magnetic resonance (MR) imaging in patients with adult TIE fractures has not been determined. We present a case of an adult type III TIE fracture seen on radiography that only with further MR imaging revealed a concomitant lateral tibial plateau fracture. Utilization of MR imaging altered the surgeon's course of treatment and postoperative care. Radiographic and MR images and a review of the literature are provided. (orig.)

  8. Do running speed and shoe cushioning influence impact loading and tibial shock in basketball players?

    Directory of Open Access Journals (Sweden)

    Wing-Kai Lam

    2018-05-01

    Full Text Available Background Tibial stress fracture (TSF is a common injury in basketball players. This condition has been associated with high tibial shock and impact loading, which can be affected by running speed, footwear condition, and footstrike pattern. However, these relationships were established in runners but not in basketball players, with very little research done on impact loading and speed. Hence, this study compared tibial shock, impact loading, and foot strike pattern in basketball players running at different speeds with different shoe cushioning properties/performances. Methods Eighteen male collegiate basketball players performed straight running trials with different shoe cushioning (regular-, better-, and best-cushioning and running speed conditions (3.0 m/s vs. 6.0 m/s on a flat instrumented runway. Tri-axial accelerometer, force plate and motion capture system were used to determine tibial accelerations, vertical ground reaction forces and footstrike patterns in each condition, respectively. Comfort perception was indicated on a 150 mm Visual Analogue Scale. A 2 (speed × 3 (footwear repeated measures ANOVA was used to examine the main effects of shoe cushioning and running speeds. Results Greater tibial shock (P 0.14; η2 = 0.13. Discussion There may be an optimal band of shoe cushioning for better protection against TSF. These findings may provide insights to formulate rehabilitation protocols for basketball players who are recovering from TSF.

  9. Increasing lateral tibial slope: is there an association with articular cartilage changes in the knee?

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Nasir; Shepel, Michael; Leswick, David A.; Obaid, Haron [University of Saskatchewan, Department of Medical Imaging, Royal University Hospital, and College of Medicine, Saskatoon, Saskatchewan (Canada)

    2014-04-15

    The geometry of the lateral tibial slope (LTS) plays an important role in the overall biomechanics of the knee. Through this study, we aim to assess the impact of LTS on cartilage degeneration in the knee. A retrospective analysis of 93 knee MRI scans (1.5 T or 3 T) for patients aged 20-45 years with no history of trauma or knee surgery, and absence of internal derangement. The LTS was calculated using the circle method. Chondropathy was graded from 0 (normal) to 3 (severe). Linear regression analysis was used for statistical analysis (p < 0.05). In our cohort of patients, a statistically significant association was seen between increasing LTS and worsening cartilage degenerative changes in the medial patellar articular surface and the lateral tibial articular surface (p < 0.05). There was no statistically significant association between increasing LTS and worsening chondropathy of the lateral patellar, medial trochlea, lateral trochlea, medial femoral, lateral femoral, and medial tibial articular surfaces. Our results show a statistically significant association between increasing LTS and worsening cartilage degenerative changes in the medial patella and the lateral tibial plateau. We speculate that increased LTS may result in increased femoral glide over the lateral tibial plateau with subsequent increased external rotation of the femur predisposing to patellofemoral articular changes. Future arthroscopic studies are needed to further confirm our findings. (orig.)

  10. Increasing lateral tibial slope: is there an association with articular cartilage changes in the knee?

    International Nuclear Information System (INIS)

    Khan, Nasir; Shepel, Michael; Leswick, David A.; Obaid, Haron

    2014-01-01

    The geometry of the lateral tibial slope (LTS) plays an important role in the overall biomechanics of the knee. Through this study, we aim to assess the impact of LTS on cartilage degeneration in the knee. A retrospective analysis of 93 knee MRI scans (1.5 T or 3 T) for patients aged 20-45 years with no history of trauma or knee surgery, and absence of internal derangement. The LTS was calculated using the circle method. Chondropathy was graded from 0 (normal) to 3 (severe). Linear regression analysis was used for statistical analysis (p < 0.05). In our cohort of patients, a statistically significant association was seen between increasing LTS and worsening cartilage degenerative changes in the medial patellar articular surface and the lateral tibial articular surface (p < 0.05). There was no statistically significant association between increasing LTS and worsening chondropathy of the lateral patellar, medial trochlea, lateral trochlea, medial femoral, lateral femoral, and medial tibial articular surfaces. Our results show a statistically significant association between increasing LTS and worsening cartilage degenerative changes in the medial patella and the lateral tibial plateau. We speculate that increased LTS may result in increased femoral glide over the lateral tibial plateau with subsequent increased external rotation of the femur predisposing to patellofemoral articular changes. Future arthroscopic studies are needed to further confirm our findings. (orig.)

  11. External laryngeal nerve in thyroid surgery: is the nerve stimulator necessary?

    Science.gov (United States)

    Aina, E N; Hisham, A N

    2001-09-01

    To find out the incidence and type of external laryngeal nerves during operations on the thyroid, and to assess the role of a nerve stimulator in detecting them. Prospective, non-randomised study. Teaching hospital, Malaysia. 317 patients who had 447 dissections between early January 1998 and late November 1999. Number and type of nerves crossing the cricothyroid space, and the usefulness of the nerve stimulator in finding them. The nerve stimulator was used in 206/447 dissections (46%). 392 external laryngeal nerves were seen (88%), of which 196/206 (95%) were detected with the stimulator. However, without the stimulator 196 nerves were detected out of 241 dissections (81%). The stimulator detected 47 (23%) Type I nerves (nerve > 1 cm from the upper edge of superior pole); 86 (42%) Type IIa nerves (nerve edge of superior pole); and 63 (31%) Type IIb nerves (nerve below upper edge of superior pole). 10 nerves were not detected. When the stimulator was not used the corresponding figures were 32 (13%), 113 (47%), and 51 (21%), and 45 nerves were not seen. If the nerve cannot be found we recommend dissection of capsule close to the medial border of the upper pole of the thyroid to avoid injury to the nerve. Although the use of the nerve stimulator seems desirable, it confers no added advantage in finding the nerve. In the event of uncertainty about whether a structure is the nerve, the stimulator may help to confirm it. However, exposure of the cricothyroid space is most important for good exposure in searching for the external laryngeal nerve.

  12. Combined CT-based and image-free navigation systems in TKA reduces postoperative outliers of rotational alignment of the tibial component.

    Science.gov (United States)

    Mitsuhashi, Shota; Akamatsu, Yasushi; Kobayashi, Hideo; Kusayama, Yoshihiro; Kumagai, Ken; Saito, Tomoyuki

    2018-02-01

    Rotational malpositioning of the tibial component can lead to poor functional outcome in TKA. Although various surgical techniques have been proposed, precise rotational placement of the tibial component was difficult to accomplish even with the use of a navigation system. The purpose of this study is to assess whether combined CT-based and image-free navigation systems replicate accurately the rotational alignment of tibial component that was preoperatively planned on CT, compared with the conventional method. We compared the number of outliers for rotational alignment of the tibial component using combined CT-based and image-free navigation systems (navigated group) with those of conventional method (conventional group). Seventy-two TKAs were performed between May 2012 and December 2014. In the navigated group, the anteroposterior axis was prepared using CT-based navigation system and the tibial component was positioned under control of the navigation. In the conventional group, the tibial component was placed with reference to the Akagi line that was determined visually. Fisher's exact probability test was performed to evaluate the results. There was a significant difference between the two groups with regard to the number of outliers: 3 outliers in the navigated group compared with 12 outliers in the conventional group (P image-free navigation systems decreased the number of rotational outliers of tibial component, and was helpful for the replication of the accurate rotational alignment of the tibial component that was preoperatively planned.

  13. 78 FR 24751 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-04-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... Control and Prevention (CDC) announces the aforementioned SEP: Time and Date: 12:00 p.m.-3:30 p.m., June...

  14. 78 FR 28221 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-05-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... aforementioned SEP: Time and Date: 12:30 p.m.-5:00 p.m. EDT, July 24, 2013 (Closed). Place: Teleconference...

  15. 78 FR 57391 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-09-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... aforementioned SEP: Times and Dates: 8:00 a.m.-8:00 p.m., November 12-15, 2013 (Closed). Place: Teleconference...

  16. Quantitative comparison of the microscopic anatomy of the human ACL femoral and tibial entheses.

    Science.gov (United States)

    Beaulieu, Mélanie L; Carey, Grace E; Schlecht, Stephen H; Wojtys, Edward M; Ashton-Miller, James A

    2015-12-01

    The femoral enthesis of the human anterior cruciate ligament (ACL) is known to be more susceptible to injury than the tibial enthesis. To determine whether anatomic differences might help explain this difference, we quantified the microscopic appearance of both entheses in 15 unembalmed knee specimens using light microscopy, toluidine blue stain and image analysis. The amount of calcified fibrocartilage and uncalcified fibrocartilage, and the ligament entheseal attachment angle were then compared between the femoral and tibial entheses via linear mixed-effects models. The results showed marked differences in anatomy between the two entheses. The femoral enthesis exhibited a 3.9-fold more acute ligament attachment angle than the tibial enthesis (p<0.001), a 43% greater calcified fibrocartilage tissue area (p<0.001), and a 226% greater uncalcified fibrocartilage depth (p<0.001), with the latter differences being particularly pronounced in the central region. We conclude that the ACL femoral enthesis has more fibrocartilage and a more acute ligament attachment angle than the tibial enthesis, which provides insight into why it is more vulnerable to failure. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Chitin biological absorbable catheters bridging sural nerve grafts transplanted into sciatic nerve defects promote nerve regeneration.

    Science.gov (United States)

    Wang, Zhi-Yong; Wang, Jian-Wei; Qin, Li-Hua; Zhang, Wei-Guang; Zhang, Pei-Xun; Jiang, Bao-Guo

    2018-06-01

    To investigate the efficacy of chitin biological absorbable catheters in a rat model of autologous nerve transplantation. A segment of sciatic nerve was removed to produce a sciatic nerve defect, and the sural nerve was cut from the ipsilateral leg and used as a graft to bridge the defect, with or without use of a chitin biological absorbable catheter surrounding the graft. The number and morphology of regenerating myelinated fibers, nerve conduction velocity, nerve function index, triceps surae muscle morphology, and sensory function were evaluated at 9 and 12 months after surgery. All of the above parameters were improved in rats in which the nerve graft was bridged with chitin biological absorbable catheters compared with rats without catheters. The results of this study indicate that use of chitin biological absorbable catheters to surround sural nerve grafts bridging sciatic nerve defects promotes recovery of structural, motor, and sensory function and improves muscle fiber morphology. © 2018 John Wiley & Sons Ltd.

  18. The origin of SEP events: New research collaboration and network on space weather

    Science.gov (United States)

    Miteva, Rositsa; Kashapova, Larisa; Myagkova, Irina; Meshalkina, Nataliia; Petrov, Nikola; Bogomolov, Andrey; Myshyakov, Ivan; Tsvetkov, Tsvetan; Danov, Dimitar; Zdanov, Dmitriy

    2017-11-01

    A new project on the solar energetic particles (SEPs) and their solar origins (flares and coronal mass ejections) is described here. The main aim of this project is to answer the question - whether the SEPs observed in situ are driven by flares, by CMEs or both accelerators contribute to an extent which varies from event to event - by deducing a quantitative measure of the flare vs. CME contribution, duration and efficiency. New observations (SONG/Koronas-F, Relec/Vernov) and new approaches of analysis will be utilized (e.g., magnetic topology of active regions using 3D extrapolation techniques of detailed case studies together with statistical analysis of the phenomena). In addition, the identification of the uncertainty limits of SEP injection, onset time and testing the validity of assumptions often taken for granted (association procedures, solar activity longitudinal effects, correlation analysis, etc.) are planned. The project outcomes have the capacity to contribute to other research fields for improvement of modeling schemes and forecasting methods of space weather events.

  19. A novel method of lengthening the accessory nerve for direct coaptation during nerve repair and nerve transfer procedures.

    Science.gov (United States)

    Tubbs, R Shane; Maldonado, Andrés A; Stoves, Yolanda; Fries, Fabian N; Li, Rong; Loukas, Marios; Oskouian, Rod J; Spinner, Robert J

    2018-01-01

    OBJECTIVE The accessory nerve is frequently repaired or used for nerve transfer. The length of accessory nerve available is often insufficient or marginal (under tension) for allowing direct coaptation during nerve repair or nerve transfer (neurotization), necessitating an interpositional graft. An attractive maneuver would facilitate lengthening of the accessory nerve for direct coaptation. The aim of the present study was to identify an anatomical method for such lengthening. METHODS In 20 adult cadavers, the C-2 or C-3 connections to the accessory nerve were identified medial to the sternocleidomastoid (SCM) muscle and the anatomy of the accessory nerve/cervical nerve fibers within the SCM was documented. The cervical nerve connections were cut. Lengths of the accessory nerve were measured. Samples of the cut C-2 and C-3 nerves were examined using immunohistochemistry. RESULTS The anatomy and adjacent neural connections within the SCM are complicated. However, after the accessory nerve was "detethered" from within the SCM and following transection, the additional length of the accessory nerve increased from a mean of 6 cm to a mean of 10.5 cm (increase of 4.5 cm) after cutting the C-2 connections, and from a mean of 6 cm to a mean length of 9 cm (increase of 3.5 cm) after cutting the C-3 connections. The additional length of accessory nerve even allowed direct repair of an infraclavicular target (i.e., the proximal musculocutaneous nerve). The cervical nerve connections were shown not to contain motor fibers. CONCLUSIONS An additional length of the accessory nerve made available in the posterior cervical triangle can facilitate direct repair or neurotization procedures, thus eliminating the need for an interpositional nerve graft, decreasing the time/distance for regeneration and potentially improving clinical outcomes.

  20. MRI diagnosis of trapped periosteum following incomplete closed reduction of distal tibial Salter-Harris II fracture

    International Nuclear Information System (INIS)

    Raman, Subha; Wallace, E.C.

    2011-01-01

    Irreducible fracture of the distal tibial physis due to interposed soft tissue including periosteum is well documented in the orthopedic literature but is uncommon. This condition has been associated with subsequent growth disturbance and requires open reduction. There are very few prior reports of MRI depiction of soft tissue interposition and none of periosteal interposition in the distal tibial physis. This is a relatively common location of physeal injury and related growth disturbance. We present a case of periosteum trapped in the distal tibial physis, diagnosed on MRI, in a Salter-Harris II fracture and its management implications. (orig.)

  1. Arthroscopic guided biopsy and radiofrequency thermoablation of a benign neoplasm of the tibial spines area: a treatment option

    Directory of Open Access Journals (Sweden)

    Zoccali Carmine

    2012-04-01

    Full Text Available Abstract Background Lesions located in the area of the tibial spines are rare. In most cases, treatment follows histological diagnosis, but when imaging and clinical data are considered to be "very" characteristic for benign lesions, such as chondroblastoma or osteoid osteoma, treatment may be performed without biopsy. Traditional curettage requires opening the joint, which presents a high risk of contamination of the joint itself and surrounding structures, such as the popliteal area, with possible contamination of the neurovascular bundle when performing curettage with the posterior approach. In this case, the re-excision of a local recurrence would be extremely difficult. Results We describe a technique using arthroscopic guidance for radiofrequency thermoablation of a benign lesion in the tibial spines area. We report on an illustrative case. The patient so treated, reported immediate relief from the pain, and after two weeks, was free of pain. The biopsy performed before the treatment confirmed the radiological diagnosis of chondroblastoma. At one year of follow-up, the patient is without pain, with a 0-130°range of motion, has no activity limitations and is apparently free of disease. Conclusion This technique allows a radiofrequency thermoablation of a lesion in the tibial spines area and in the posterior tibial surface to be performed without opening the joint, monitoring the tibial plateau surface, probably decreasing the risk of cartilage damage. Unfortunately, in the case presented, the high pressure from the arthroscopy's pump broke the tibial plateau surface creating a communication to the tibial tunnel used for thermoablation.

  2. A STUDY ON TIBIAL TORSION IN ADULT DRY TIBIA OF EAST AND SOUTH INDIAN POPULATION

    Directory of Open Access Journals (Sweden)

    Jami Sagar Prusti

    2017-05-01

    Full Text Available BACKGROUND Rotational deformities of the lower limbs are very common. There is increasing evidence that abnormal torsion in the tibia is associated with severe knee and ankle arthritis. Primary knee osteoarthritis is a leading cause of disability in older persons. Varus or valgus alignment increases the risk of osteoarthritis. Coexistence of tibial torsional deformity may increase the risk further. Variability in the tibial torsion has been reported and is due to the torsional forces applied on tibia during development. The aim of the study is to estimate the angle of tibial torsion on both sides and both sexes. The present study was an attempt to provide baseline data of tibial torsion in the East and South Indian population. MATERIALS AND METHODS The study was conducted mechanically on 100 dry adult unpaired human tibia, i.e. 50 male and 50 female bones. The measurements were recorded and statistically analysed using Student’s unpaired t-test using GraphPad Prism 5.0 (free trial version. RESULTS Out of the 100 tibia undertaken, mean value of tibial torsion angle obtained is 25.8°. In males, it is 23.68° and in females it is about 27.86°. Statistical analysis revealed significant greater average angle of tibial torsion in female bones. The angle of the right-sided bones was more and this was statistically significant. CONCLUSION The gender variation for the angle could be the result of the difference in lifestyle in day-to-day activities. The knowledge of the angle in a population could be helpful in understanding the incidence of pathogenesis related to gait and knee osteoarthritis and in view of reconstructive surgeries in orthopaedic practice.

  3. 78 FR 20319 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review.

    Science.gov (United States)

    2013-04-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review. The meeting... aforementioned SEP: Time and Date: 9:00 a.m.-6:00 p.m., May 15-16, 2013 (Closed). Place: Georgian Terrace, 659...

  4. Aragats space-environmental centre: status and SEP forecasting possibilities

    Energy Technology Data Exchange (ETDEWEB)

    Chilingarian, A; Avakyan, K; Babayan, V; Bostanjyan, N; Chilingarian, S; Eganov, V; Hovhanissyan, A; Karapetyan, G; Gevorgyan, N; Gharagyozyan, G; Ghazaryan, S; Garyaka, A; Ivanov, V; Martirosian, H; Martirosov, R; Melkumyan, L; Sogoyan, H; Sokhoyan, S; Tserunyan, S; Vardanyan, A; Zazyan, M [Cosmic Ray Division, Yerevan Physics Institute, Alikhanyan Brothers 2, Yerevan 36 (Armenia); Yeremian, A [Stanford Linear Accelerator Center, Stanford, CA 94309 (United States)

    2003-05-01

    The Aragats Space Environment Center in Armenia provides real-time monitoring of cosmic particle fluxes. Neutron monitors operating at altitudes of 2000 m and 3200 m on Mt Aragats continuously gather data to detect possible abrupt enhancement of the count rates. Additional high precision detectors, measuring muon and electron fluxes, along with directional information have been put in operation on Mt Aragats in the summer of 2002. We plan to use this information to establish an early warning system against extreme solar energetic particle (SEP) events which pose danger to the satellite electronics and the space station crew. Solar ion and proton fluxes as measured by space-borne sensors on ACE and GOES satellites are used to derive expected arrival times of highest energy ions at 1 AU. The peaks in the time series detected by Aragats neutron monitors, coincided with these times, demonstrate the possibility of early detection of SEP events using the ground-based detectors.

  5. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    Science.gov (United States)

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile

  6. The effect of tibial slope on the biomechanics of cruciate-retaining TKA : a musculoskeletal simulation study

    NARCIS (Netherlands)

    Marra, Marco A.; Strzelczak, Marta; Heesterbeek, Petra J.C.; van de Groes, Sebastiaan; Janssen, Dennis W.; Koopman, Bart F.J.M.; Wymenga, Ate B.; Verdonschot, Nico J.J.

    2017-01-01

    INTRODUCTION: Tibial slope can affect the outcomes of Total Knee Arthroplasty (TKA). More posterior slope potentially helps releasing a too tight flexion gap and it is generally associated with a wider range of post-operative knee flexion. However, the mechanism by which tibial slope affects the

  7. Chronic exertional compartment syndrome with medial tibial stress syndrome in twins.

    Science.gov (United States)

    Banerjee, Purnajyoti; McLean, Christopher

    2011-06-14

    Chronic exertional compartment syndrome and medial tibial stress syndrome are uncommon conditions that affect long-distance runners or players involved in team sports that require extensive running. We report 2 cases of bilateral chronic exertional compartment syndrome, with medial tibial stress syndrome in identical twins diagnosed with the use of a Kodiag monitor (B. Braun Medical, Sheffield, United Kingdom) fulfilling the modified diagnostic criteria for chronic exertional compartment syndrome as described by Pedowitz et al, which includes: (1) pre-exercise compartment pressure level >15 mm Hg; (2) 1 minute post-exercise pressure >30 mm Hg; and (3) 5 minutes post-exercise pressure >20 mm Hg in the presence of clinical features. Both patients were treated with bilateral anterior fasciotomies through minimal incision and deep posterior fasciotomies with tibial periosteal stripping performed through longer anteromedial incisions under direct vision followed by intensive physiotherapy resulting in complete symptomatic recovery. The etiology of chronic exertional compartment syndrome is not fully understood, but it is postulated abnormal increases in intramuscular pressure during exercise impair local perfusion, causing ischemic muscle pain. No familial predisposition has been reported to date. However, some authors have found that no significant difference exists in the relative perfusion, in patients, diagnosed with chronic exertional compartment syndrome. Magnetic resonance images of affected compartments have indicated that the pain is not due to ischemia, but rather from a disproportionate oxygen supply versus demand. We believe this is the first report of chronic exertional compartment syndrome with medial tibial stress syndrome in twins, raising the question of whether there is a genetic predisposition to the causation of these conditions. Copyright 2011, SLACK Incorporated.

  8. Nanofiber Nerve Guide for Peripheral Nerve Repair and Regeneration

    Science.gov (United States)

    2016-04-01

    1 Award Number: W81XWH-11-2-0047 TITLE: Nanofiber Nerve Guide for Peripheral Nerve Repair and Regeneration PRINCIPAL INVESTIGATOR: Ahmet Höke...TITLE AND SUBTITLE 5a. CONTRACT NUMBER W81XWH-11-2-0047 Nanofiber nerve guide for peripheral nerve repair and regeneration 5b. GRANT NUMBER...goal of this collaborative research project was to develop next generation engineered nerve guide conduits (NGCs) with aligned nanofibers and

  9. EMG and tibial shock upon the first attempt at barefoot running.

    Science.gov (United States)

    Olin, Evan D; Gutierrez, Gregory M

    2013-04-01

    As a potential means to decrease their risk of injury, many runners are transitioning into barefoot running. Habitually shod runners tend to heel-strike (SHS), landing on their heel first, while barefoot runners tend to mid-foot or toe-strike (BTS), landing flat-footed or on the ball of their foot before bringing down the rest of the foot including the heel. This study compared muscle activity, tibial shock, and knee flexion angle in subjects between shod and barefoot conditions. Eighteen habitually SHS recreational runners ran for 3 separate 7-minute trials, including SHS, barefoot heel-strike (BHS), and BTS conditions. EMG, tibial shock, and knee flexion angle were monitored using bipolar surface electrodes, an accelerometer, and an electrogoniometer, respectively. A one-way MANOVA for repeated measures was conducted and several significant changes were noted between SHS and BTS, including significant increases in average EMG of the medial gastrocnemius (p=.05), average and peak tibial shock (pknee flexion angle (pinjurious, these data indicate that habitually SHS runners who choose to transition into a BTS technique must undertake the process cautiously. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. All-arthroscopic treatment of tibial avulsion fractures of the posterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Gwinner, Clemens

    2016-01-01

    Full Text Available Background: The posterior cruciate ligament (PCL avulsion fracture from its tibial insertion is a rare condition. Despite the further technical advent in refixation of avulsion fractures, the reported failure rate of current approaches remains high and the optimal surgical technique has not been elucidated yet.The purpose of the current study is to present an all-inside arthroscopic reconstruction technique for bony tibial avulsion fractures of the PCL and initial clinical outcomes. Methods: Patients underwent a thorough clinical and radiological examination of both knees at 3, 6, 12, 18, and if possible also at 24 months.Clinical evaluation included subjective and objective IKDC 2000, Lysholm score, and KOOS score. Radiographic imaging studies included CT scans for assessment of osseous integration and anatomic reduction of the bony avulsion. In addition to that posterior stress radiographs of both knees using the Telos device (Arthrex, Naples, USA were conducted to measure posterior tibial translation.Results: A total of four patients (1 female, 3 male; ø 38 (± 18 years, who underwent arthroscopic refixation of a PCL avulsion fracture using the Tight Rope device were enrolled in this study. Mean follow up was 22 [18–24] months. The mean subjective IKDC was 72.6% (± 9.9%. Regarding the objective IKDC three patients accounted for grade A, one patient for grade C. The Lysholm score yielded 82 (± 6.9 points. The KOOS score reached 75% (± 13%; symptoms 76%, pain 81%, function 76%, sports 66%, QoL 64%.All patients showed complete osseous integration and anatomic reduction of the bony avulsion. The mean posterior tibial translation at final follow up was 2.8 [0–7] mm. Conclusions: All-arthroscopic treatment of tibial avulsion fractures of the posterior cruciate ligament provides satisfactory clinical results in a preliminary patient cohort. It is a reproducible technique, which minimizes soft tissue damage and obviates a second surgery for

  11. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    Science.gov (United States)

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  12. Radial nerve dysfunction

    Science.gov (United States)

    Neuropathy - radial nerve; Radial nerve palsy; Mononeuropathy ... Damage to one nerve group, such as the radial nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  13. Tibial slope correction combined with second revision ACL produces good knee stability and prevents graft rupture.

    Science.gov (United States)

    Dejour, David; Saffarini, Mo; Demey, Guillaume; Baverel, Laurent

    2015-10-01

    Revision ACL reconstruction requires careful analysis of failure causes particularly in cases of two previous graft ruptures. Intrinsic factors as excessive tibial slope or narrow femoral notch increase failure risks but are rarely addressed in revision surgery. The authors report outcomes, at minimum follow-up of 2 years, for second revision ACL reconstructions combined with tibial deflexion osteotomy for correction of excessive slope (>12°). Nine patients that underwent second revision ACL reconstruction combined with tibial deflexion osteotomy were retrospectively studied. The mean age was 30.3 ± 4.4 years (median 28; range 26-37), and mean follow-up was 4.0 ± 2.0 years (median 3.6; range 2.0-7.6). Autografts were harvested from the quadriceps tendon (n = 8) or hamstrings (n = 1), and tibial osteotomy was done by anterior closing wedge, without detachment of the patellar tendon, to obtain a slope of 3° to 5°. All patients had fused osteotomies, stable knees, and there were no intraoperative or postoperative complications. The mean posterior tibial slope decreased from 13.2° ± 2.6° (median 13°; range 12°-18°) preoperatively to 4.4° ± 2.3° (median 4°; range 2°-8°) postoperatively. The mean Lysholm score was 73.8 ± 5.8 (median 74; range 65-82), and the IKDC-SKF was 71.6 ± 6.1 (median 72.8; range 62.2-78.5). The satisfactory results of second revision ACL reconstruction combined with tibial deflexion osteotomy at minimum follow-up of 2 years suggest that tibia slope correction protects reconstructed ACL from fatigue failure in this study. The authors stress the importance of careful analysis failure causes prior to revision ACL reconstruction, and recommend correction of tibial slope if it exceeds 12°, to reduce the risks of graft retear. III.

  14. Radial and tibial bone indices in athletes participating in different endurance sports: a pQCT study.

    Science.gov (United States)

    Oosthuyse, Tanja; McVeigh, Joanne A; Micklesfield, Lisa K; Meiring, Rebecca M

    2017-03-01

    Low magnitude bone-loading sports may benefit bone structure and strength in the exercised limbs. This study compared peripheral quantitative computed tomography measures of radial and tibial diaphyseal strength (strength-strain index, SSI), structure (total area (ToA) and cortical area (CoA), density (CoD) and thickness (CT), and circumferences), muscle cross-sectional area (MCSA) and strength (one-repetition maximum, 1-RM) in male endurance athletes taking part in (i) non-weight-bearing and non-impact sports: swimmers (SWIM, n = 13) and road cyclists (RC, n = 10), (ii) non-weight-bearing, impact sport: mountain bikers (MB, n = 10), (iii) weight bearing and impact sport: runners (RUN, n = 9). All athlete groups were also compared to sedentary controls (CON, n = 10). Arm MCSA, 1-RM and radial bone size and strength tended to be greater in SWIM than CON and/or RC (ToA, %difference  ± 95%CI, SWIM-CON: 14.6% ± 12.7%; SWIM-RC: 12.9% ± 10.7%) but not different to MB and RUN. RUN had bigger tibial CoA than CON, SWIM and RC (CoA, RUN-CON: 12.1% ± 10.7%; RUN-SWIM: 10.9% ± 9.4%; RUN-RC: 15.8% ± 9.5%) without marked changes in tibial strength indices, lower-limb MCSA or 1-RM. Both MB and RC failed to display any difference in tibial indices, lower-limb MCSA and 1-RM compared to CON. In swimmers, the bone structure and strength of the primary exercised limbs, the arms, is greater than controls and road cyclists. Conversely, although runners experience impact and weight-bearing loading, tibial structure is greater without a substantial difference in tibial strength compared to controls and non-impact sports. Failure to observe a difference in tibial indices in MB and RC compared to controls is unexpected.

  15. Malignant peripheral nerve sheath tumor of the oculomotor nerve

    DEFF Research Database (Denmark)

    Kozic, D; Nagulic, M; Ostojic, J

    2006-01-01

    We present the short-term follow-up magnetic resonance (MR) studies and 1H-MR spectroscopy in a child with malignant peripheral nerve sheath tumor of the oculomotor nerve associated with other less aggressive cranial nerve schwannomas. The tumor revealed perineural extension and diffuse nerve...

  16. Communication between radial nerve and medial cutaneous nerve of forearm

    Directory of Open Access Journals (Sweden)

    R R Marathe

    2010-01-01

    Full Text Available Radial nerve is usually a branch of the posterior cord of the brachial plexus. It innervates triceps, anconeous, brachialis, brachioradialis, extensor carpi radialis longus muscles and gives the posterior cutaneous nerve of the arm, lower lateral cutaneous nerve of arm, posterior cutaneous nerve of forearm; without exhibiting any communication with the medial cutaneous nerve of forearm or any other nerve. We report communication between the radial nerve and medial cutaneous nerve of forearm on the left side in a 58-year-old male cadaver. The right sided structures were found to be normal. Neurosurgeons should keep such variations in mind while performing the surgeries of axilla and upper arm.

  17. Transcutaneous Spinal Direct Current Stimulation (tsDCS

    Directory of Open Access Journals (Sweden)

    Filippo eCogiamanian

    2012-07-01

    Full Text Available In the past ten years renewed interest has centered on non-invasive transcutaneous weak direct currents applied over the scalp to modulate cortical excitability (brain polarization or transcranial direct current stimulation, tDCS. Extensive literature shows that tDCS induces marked changes in cortical excitability that outlast stimulation.Aiming at developing a new, non invasive, approach to spinal cord neuromodulation we assessed the after-effects of thoracic transcutaneous spinal DC stimulation (tsDCS on somatosensory potentials (SEPs evoked in healthy subjects by posterior tibial nerve (PTN stimulation. Our findings showed that thoracic anodal tsDCS depresses the cervico-medullary PTN-SEP component (P30 without eliciting adverse effects. tsDCS also modulates post-activation H-reflex dynamics. Later works further confirmed that transcutaneous electric fields modulate spinal cord function. Subsequent studies in our laboratory showed that tsDCS modulates the flexion reflex in the human lower limb. Besides influencing the laser evoked potentials, tsDCS increases pain tolerance in healthy subjects. Hence, though the underlying mechanisms remain speculative, tsDCS modulates activity in lemniscal, spinothalamic and segmental motor systems.Here we review currently available experimental evidence that non-invasive spinal cord stimulation influences spinal function in humans and argue that, by focally modulating spinal excitability, tsDCS could provide a novel therapeutic tool complementary to drugs and invasive spinal cord stimulation in managing various pathologic conditions, including pain.

  18. Neglected, semimembranosus osteochondral avulsion fracture of the posteromedial tibial plateau

    Directory of Open Access Journals (Sweden)

    Rakesh John

    2018-06-01

    Full Text Available Semimembranosus avulsion fracture is infrequently reported and is easy to miss on plain radiographs; the mechanism of injury is highly controversial. Initial reports linked it to anterior cruciate ligament and medial meniscal tears. We report an osteochondral semimembranosus avulsion fracture of the posteromedial tibial plateau with associated posterior cruciate ligament rupture. Also described is a novel surgical fixation technique for such osteochondral fractures where the surgical exposure is limited due to the obliquity of the fracture line resulting in a greater involvement of the articular cartilage than the small bony component. The fixation technique described may be used for osteochondral fractures where the application of a conventional compression screw may not be feasible. Keywords: Osteochondral fracture, Semimembranosus avulsion fracture, Posteromedial tibial plateau, Neglected, Nonunion

  19. Ulnar nerve dysfunction

    Science.gov (United States)

    Neuropathy - ulnar nerve; Ulnar nerve palsy; Mononeuropathy; Cubital tunnel syndrome ... Damage to one nerve group, such as the ulnar nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  20. Studies on UV/NaOCl/TiO2/Sep photocatalysed degradation of Reactive Red 195.

    Science.gov (United States)

    Karaoğlu, M Hamdi; Uğurlu, Mehmet

    2010-02-15

    The photocatalytic degradation of Reactive Red 195 (RR195) has been investigated in aqueous suspensions by using ultraviolet (UV), sodium hypochlorite (NaOCl) and TiO(2)/Sep nanoparticles together. To get the TiO(2)/Sep nanoparticle, the nanocrystalline TiO(2) anatase phase on sepiolite was obtained using a sufficient thermal treatment by gradually increasing the temperature from 300, 400 and 500 degrees C for 3h. Then, TiO(2)/Sep materials were characterized using different spectral and technical structural analyses with scanning electron microscopy (SEM) and X-ray diffraction (XRD). The influence of pH, catalyst amount, oxidant and initial dye concentration was investigated in all the experiments. Maximum colour and chemical oxygen demand (COD) removal were 99.9% and 78% respectively, at a dye concentration of 250 mg L(-1), NaOCl dosage of 50.37 mM, 0.1 g L(-1) weight of TiO(2)/Sep and pH of 5.45 in 3h. In addition, the pseudo-first order model was applied and r(2) values were noted from 0.92 to 0.99.

  1. Bone Morphogenetic Protein for the Healing of Tibial Fracture: A Meta-Analysis of Randomized Controlled Trials.

    Directory of Open Access Journals (Sweden)

    Jiezhi Dai

    Full Text Available To review the evidence from RCTs on clinical outcomes and benefit of acute tibial fracture and nonunion treated with and without BMPs.We searched multiple databases (MEDLINE, EMABSE, BIOSIS and Cochrane central as well as reference lists of articles and contacted authors. Evaluated outcomes included union rate, revision rate, hardware failure and infection. The weighted and standard mean difference (WMD and SMD or the relative risk (RR was calculated for continuous or dichotomous data respectively. The quality of the trial was assessed, and meta-analyses were performed with the Cochrane Collaboration's REVMAN 5.0 software.Eight RCTs involving 1113 patients were included. For acute tibial fracture, BMP group was associated with a higher rate of union (RR, 1.16; 95% CI, 1.04 to 1.30 and a lower rate of revision (RR, 0.68; 95% CI, 0.54 to 0.85 compared with control group. No significant differences were found in rate of hardware failure and infection. The pooled RR for achieving union for tibial fracture nonunion was 0.98 (95% CI, 0.86 to 1.13. There was no significant difference between the two groups in the rate of revision (RR, 0.48; 95% CI, 0.13 to 1.85 and infection (RR, 0.61; 95% CI, 0.37 to 1.02.Study on acute tibial fractures suggests that BMP is more effective that controls, for bone union and for decreasing the rate of surgical revision to achieve union. For the treatment of tibial fracture nonunion, BMP leads to similar results to as autogenous bone grafting. Finally, well-designed RCTs of BMP for tibial fracture treatment are also needed.

  2. Ten-year survival and patient-reported outcomes of a medial unicompartmental knee arthroplasty incorporating an all-polyethylene tibial component.

    Science.gov (United States)

    Scott, Chloe E H; Wade, Frazer A; MacDonald, Deborah; Nutton, Richard W

    2018-05-01

    Biomechanical studies have suggested that proximal tibial strain is elevated in UKAs incorporating all-polyethylene tibial components with concern that this leads to premature failure. This study reports minimum 10-year outcomes for a UKA incorporating an all-polyethylene tibial component to determine whether these concerns were realised. 109 fixed bearing UKAs (97 patients, mean age 68 (range 48-87), 54/97 (56%) female) with all-polyethylene tibial components were followed up for ≥ 10 years with Oxford Knee Scores, Forgotten Joint Scores and Kaplan-Meier analysis. 106/109 implants were 7 mm, 3 were 9.5 mm. Ten-year survival was 85.5% (78.6-92.4 95% CI) with the end-point failure for any reason. Unexplained pain was the commonest mode of failure (6/17) followed by lateral compartment osteoarthritis (5/17) and tibial subsidence/loosening (4/17). Revision rate was highest at 2-5 years due to revisions for unexplained pain. Ten-year survival was worse in patients  30 (p = 0.017) and in those with postoperative increases in medial tibial sclerosis (p  30 was 2.9 (1.2-6.9 95% CI). In those with intact UKAs at 10 years, mean Oxford Knee Score was 34.8 ± 10.7, Forgotten Joint Score was 37.9 ± 26.7 and 96% were satisfied with their knee. The high rate of early failure between 2 and 5 years in this all-polyethylene tibial component UKA did not persist in the long term. Though medial proximal tibial metabolic changes appear to persist they are not necessarily symptomatic. BMI > 30 and age < 65 years were significant risk factors for revision.

  3. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty; Valutazione con Tomografia Computerizzata della rotazione delle componenti femorale e tibiale nell'artroprotesi totale del ginocchio

    Energy Technology Data Exchange (ETDEWEB)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M. [Istituto Ortopedico Rizzoli, Bologna (Italy). Servizio di Diagnostica per Immagini; Trentani, F.; Trentani, P.; Tigani, D. [Istituto Ortopedico Rizzoli, Bologna (Italy). VII Div.; Nigrosoli, M. [Istituto Ortopedico Rizzoli, Bologna (Italy). IV Div.

    2000-06-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteria were prosthesis loosening and severe (equal or superior to 7 degrees) varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  4. The usefulness of MR myelography for evaluation of nerve root avulsion in brachial plexus injury

    International Nuclear Information System (INIS)

    Nishiura, Yasumasa; Ochiai, Naoyuki; Miyauchi, Yukio; Niitsu, Mamoru

    2002-01-01

    Myelography has been the most popular and reliable method for evaluation of nerve root avulsion in brachial plexus injury. However, it is invasive because it requires the use of contrast medium, dural puncture and exposure to radiation. In addition, it has a fault. When a nerve rootlet is not filled with contrast medium, it is impossible to evaluate it. It has sometimes been a problem in the injury to upper roots. Recently, MRI also has been used for diagnosis of brachial plexus injury. But it was not until recently that it has had a high resolution to detect affected nerve rootlets. We have used MR myelography with high resolution for diagnosis of brachial plexus injury. The purpose of this study is to investigate the usefulness of it. MR myelography was preoperatively performed in 14 cases, consisting of 13 traumatic brachial plexus injuries and an obstetrical palsy. In them, 12 cases had root avulsion injuries and 2 cases had infraclavicular injuries. A 1.5 Tesla MR system (Philips) and a cervical coil were used. Coronal sections with 2 mm-overcontiguous thickness were obtained by heavily T2-weighted sequence fast spin echo (TR/TE=3000/450). The fat signal was suppressed by a presaturation inversion-pulse. The scanning time was about five minutes. The three-dimensional image was reconstructed by using maximum intensity projection (MIP) method. MIP images and individual coronal images were used for evaluation for root avulsion. In evaluation the shape of a nerve sleeve and nerve rootlets was compared on both sides. The abnormal shape of a nerve sleeve or the defect of nerve rootlets was diagnosed as root avulsion. The brachial plexus lesions were exposed operatively and examined with electrophysiologic methods (SEP and/or ESCP) in all cases. Operative findings were compared with MR myelography. Twenty-four roots had been diagnosed as normal and 46 roots had been diagnosed as root avulsion with MR myelography preoperatively. In the former only one root was

  5. The anti-lung cancer activity of SEP is mediated by the activation and cytotoxicity of NK cells via TLR2/4 in vivo.

    Science.gov (United States)

    Ke, Mengyun; Wang, Hui; Zhang, Min; Tian, Yuwei; Wang, Yizhou; Li, Bing; Yu, Jie; Dou, Jie; Xi, Tao; Zhou, Changlin

    2014-05-01

    Strongylocentrotus nudus egg polysaccharide (SEP) has been reported to display antitumor activity. However, the effects of SEP and its underlying mechanism in the treatment of lung cancer remain unclear, particularly with an immunodeficient mouse model of human non-small cell lung cancer (NSCLC). In the present study, we investigated the anti-lung cancer effects of SEP and its underlying mechanism of action in both Lewis lung cancer (LLC)-bearing C57/BL6J mice and human NSCLC H460-bearing nude mice. Although SEP showed no inhibitory effects on tumor cells in vitro, it markedly stimulated the percentage of CD3-NK1.1(+) cells and natural killer (NK) cell cytotoxicity in the spleens of nude mice and C57/BL6J mice. In LLC-bearing mice, SEP not only inhibited tumor growth but also promoted NK-mediated cytotoxicity, the NK1.1(+) cell population, and IL-2 and IFN-γ secretion. SEP significantly suppressed H460 growth in nude mice, which was abrogated by the selective depletion of NK cells via the intraperitoneal injection of anti-asialo GM-1 antibodies. Furthermore, anti-TLR2/4 antibodies blocked both SEP and NK cell binding and SEP-induced perforin secretion. SEP-induced proliferation and IFN-γ secretion by NK cells in wild type mice were partially impaired in TLR2 or TLR4 knockout mice. These results suggest that SEP-promoted NK cytotoxicity, which was partially mediated via TLR2 and TLR4, was the main contributing factor to lung cancer inhibition in vivo and that SEP may be a potential immunotherapy candidate for the treatment of lung cancer. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Erythrocyte remodeling in Plasmodium berghei infection: the contribution of SEP family members.

    Science.gov (United States)

    Currà, Chiara; Pace, Tomasino; Franke-Fayard, Blandine M D; Picci, Leonardo; Bertuccini, Lucia; Ponzi, Marta

    2012-03-01

    The malaria parasite Plasmodium largely modifies the infected erythrocyte through the export of proteins to multiple sites within the host cell. This remodeling is crucial for pathology and translocation of virulence factors to the erythrocyte surface. In this study, we investigated localization and export of small exported proteins/early transcribed membrane proteins (SEP/ETRAMPs), conserved within Plasmodium genus. This protein family is characterized by a predicted signal peptide, a short lysine-rich stretch, an internal transmembrane domain and a highly charged C-terminal region of variable length. We show here that members of the rodent Plasmodium berghei family are components of the parasitophorous vacuole membrane (PVM), which surrounds the parasite throughout the erythrocytic cycle. During P. berghei development, vesicle-like structures containing these proteins detach from the PVM en route to the host cytosol. These SEP-containing vesicles remain associated with the infected erythrocyte ghosts most probably anchored to the membrane skeleton. Transgenic lines expressing the green fluorescent protein appended to different portions of sep-coding region allowed us to define motifs required for protein export. The highly charged terminal region appears to be involved in protein-protein interactions. © 2011 John Wiley & Sons A/S.

  7. Posterior Tibial Slope Angle Correlates With Peak Sagittal and Frontal Plane Knee Joint Loading During Robotic Simulations of Athletic Tasks

    Science.gov (United States)

    Bates, Nathaniel A.; Nesbitt, Rebecca J.; Shearn, Jason T.; Myer, Gregory D.; Hewett, Timothy E.

    2017-01-01

    Background Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. Purpose To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Study Design Descriptive laboratory study. Methods A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, −7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. Results The mean (6SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60–0.65), flexion (r = 0.64–0.66), lateral (r = 0.57–0.69), and external rotation torques (r = 0.47–0.72) as well as inverse correlations with peak abduction (r = −0.42 to −0.61) and internal rotation torques (r = −0.39 to −0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64–0.69) and lateral knee force (r = 0.55–0.74) as well as inverse correlations with peak external torque (r = −0.34 to 20.67) and medial knee force (r = −0.58 to −0.59). These moderate correlations were also present during simulated sidestep cutting. Conclusion The investigation supported the theory that increased posterior

  8. The First Experience of Triple Nerve Transfer in Proximal Radial Nerve Palsy.

    Science.gov (United States)

    Emamhadi, Mohammadreza; Andalib, Sasan

    2018-01-01

    Injury to distal portion of posterior cord of brachial plexus leads to palsy of radial and axillary nerves. Symptoms are usually motor deficits of the deltoid muscle; triceps brachii muscle; and extensor muscles of the wrist, thumb, and fingers. Tendon transfers, nerve grafts, and nerve transfers are options for surgical treatment of proximal radial nerve palsy to restore some motor functions. Tendon transfer is painful, requires a long immobilization, and decreases donor muscle strength; nevertheless, nerve transfer produces promising outcomes. We present a patient with proximal radial nerve palsy following a blunt injury undergoing triple nerve transfer. The patient was involved in a motorcycle accident with complete palsy of the radial and axillary nerves. After 6 months, on admission, he showed spontaneous recovery of axillary nerve palsy, but radial nerve palsy remained. We performed triple nerve transfer, fascicle of ulnar nerve to long head of the triceps branch of radial nerve, flexor digitorum superficialis branch of median nerve to extensor carpi radialis brevis branch of radial nerve, and flexor carpi radialis branch of median nerve to posterior interosseous nerve, for restoration of elbow, wrist, and finger extensions, respectively. Our experience confirmed functional elbow, wrist, and finger extensions in the patient. Triple nerve transfer restores functions of the upper limb in patients with debilitating radial nerve palsy after blunt injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Do Capacity Coupled Electric Fields Accelerate Tibial Stress Fracture Healing?

    National Research Council Canada - National Science Library

    Hoffman, Andrew

    2004-01-01

    A convenience sample based on availability of tibial stress fracture cases a% local Sports Medicine Clinics will be selected over 4 years until forty subjects (20 male, 20 female) have been treated...

  10. Accelerated tibial fracture union in the third trimester of pregnancy: a case report

    Directory of Open Access Journals (Sweden)

    Ahmad Mudussar A

    2008-02-01

    Full Text Available Abstract Introduction We present a case of accelerated tibial fracture union in the third trimester of pregnancy. This is of particular relevance to orthopaedic surgeons, who must be made aware of the potentially accelerated healing response in pregnancy and the requirement for prompt treatment. Case presentation A 40 year old woman at 34 weeks gestational age sustained a displaced fracture of the tibial shaft. This was initially treated conservatively in plaster with view to intra-medullary nailing postpartum. Following an emergency caesarean section, the patient was able to fully weight bear without pain 4 weeks post injury, indicating clinical union. Radiographs demonstrated radiological union with good alignment and abundant callus formation. Fracture union occurred within 4 weeks, less than half the time expected for a conservatively treated tibial shaft fracture. Conclusion Long bone fractures in pregnancy require clear and precise management plans as fracture healing is potentially accelerated. Non-operative treatment is advisable provided satisfactory alignment of the fracture is achieved.

  11. Corticospinal and Spinal Excitabilities Are Modulated during Motor Imagery Associated with Somatosensory Electrical Nerve Stimulation

    Directory of Open Access Journals (Sweden)

    E. Traverse

    2018-01-01

    Full Text Available Motor imagery (MI, the mental simulation of an action, influences the cortical, corticospinal, and spinal levels, despite the lack of somatosensory afferent feedbacks. The aim of this study was to analyze the effect of MI associated with somatosensory stimulation (SS on the corticospinal and spinal excitabilities. We used transcranial magnetic stimulation and peripheral nerve stimulation to induce motor-evoked potentials (MEP and H-reflexes, respectively, in soleus and medialis gastrocnemius (MG muscles of the right leg. Twelve participants performed three tasks: (1 MI of submaximal plantar flexion, (2 SS at 65 Hz on the posterior tibial nerve with an intensity below the motor threshold, and (3 MI + SS. MEP and H-reflex amplitudes were recorded before, during, and after the tasks. Our results confirmed that MI increased corticospinal excitability in a time-specific manner. We found that MI+SS tended to potentiate MEP amplitude of the MG muscle compared to MI alone. We confirmed that SS decreased spinal excitability, and this decrease was partially compensated when combined with MI, especially for the MG muscle. The increase of CSE could be explained by a modulation of the spinal inhibitions induced by SS, depending on the amount of afferent feedbacks.

  12. Fratura periprotética da tíbia combinada com fratura de fadiga da haste tibial de artroplastia total do joelho Tibial periprosthetic fracture combined with tibial stem stress fracture from total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Fernando Fonseca

    2011-01-01

    Full Text Available As complicações das artroplastias totais do joelho relacionadas com o próprio material são muito raras, exceto o desgaste do polietileno. Neste artigo os autores reportam o caso de uma paciente do sexo feminino de 58 anos referenciada ao pronto-socorro do nosso hospital por uma fratura periprotética tibial (tipo I da classificação da Mayo Clinic. Uma observação mais cuidadosa mostrou a presença concomitante da referida fratura da tíbia associada à fratura de fadiga da haste tibial. A prótese com a haste foi remetida a um laboratório de biomecânica independente onde foi avaliada e efetuada uma reconstrução com uso de sistema de elementos finitos em CAD de modo a verificar a existência de algum defeito de fabricação e as eventuais causas para o sucedido. Depois de avaliadas diversas hipóteses, concluiu-se que a fratura do material foi provocada por uma sobrecarga na zona de transição prato/haste secundária à falência óssea prévia (fratura. Da avaliação do caso ressalta-se novamente a necessidade de efetuar uma avaliação adequada da mineralização óssea e, em caso de dúvida, utilizar uma haste longa.Total knee arthroplasty complications related to the prosthetic material are very rare, except for polyethylene wear. We report the case of a 58-year-old woman who came to the emergency service of our hospital with a periprosthetic tibial fracture (Mayo Clinic type I. Careful examination showed that this fracture was concomitantly associated with a tibial stem fatigue fracture. The prosthesis and the stem were sent to an independent biomechanics laboratory for evaluation. A finite-element CAD system was used to make a reconstruction, so as to ascertain whether there had been any manufacturing defect and what the causes of the event might have been. After evaluation of several hypotheses, it was concluded that the fracture in the prosthetic material had been caused by overloading at the plate/stem transition zone

  13. One-stage human acellular nerve allograft reconstruction for digital nerve defects

    Directory of Open Access Journals (Sweden)

    Xue-yuan Li

    2015-01-01

    Full Text Available Human acellular nerve allografts have a wide range of donor origin and can effectively avoid nerve injury in the donor area. Very little is known about one-stage reconstruction of digital nerve defects. The present study observed the feasibility and effectiveness of human acellular nerve allograft in the reconstruction of < 5-cm digital nerve defects within 6 hours after injury. A total of 15 cases of nerve injury, combined with nerve defects in 18 digits from the Department of Emergency were enrolled in this study. After debridement, digital nerves were reconstructed using human acellular nerve allografts. The patients were followed up for 6-24 months after reconstruction. Mackinnon-Dellon static two-point discrimination results showed excellent and good rates of 89%. Semmes-Weinstein monofilament test demonstrated that light touch was normal, with an obvious improvement rate of 78%. These findings confirmed that human acellular nerve allograft for one-stage reconstruction of digital nerve defect after hand injury is feasible, which provides a novel trend for peripheral nerve reconstruction.

  14. Nerves and nerve endings in the skin of tropical cattle.

    Science.gov (United States)

    Amakiri, S F; Ozoya, S E; Ogunnaike, P O

    1978-01-01

    The nerves and nerve endings in the skin of tropical cattle were studied using histological and histochemical techniques. Many nerve trunks and fibres were present in the reticular and papillary dermis in both hairy and non-hairy skin sites. In non-hairy skin locations such as the muzzle and lower lip, encapsulated endings akin to Krause and Ruffini end bulbs, which arise from myelinated nerve trunks situated lower down the dermis were observed at the upper papillary layer level. Some fibre trunks seen at this level extended upwards to terminate within dermal papillae as bulb-shaped longitudinally lamellated Pacinian-type endings, while other onion-shaped lamellated nerve structures were located either within dermal papillae or near the dermo-epidermal area. Intraepidermal free-ending nerve fibres, appearing non-myelinated were observed in areas with thick epidermis. Intraepidermal free-ending nerve fibres, appearing non-myelinated were observed in areas with thick epidermis. On hairy skin sites, however, organized nerve endings or intraepidermal nerve endings were not readily identifiable.

  15. The effect of proximal tibial slope on dynamic stability testing of the posterior cruciate ligament- and posterolateral corner-deficient knee.

    Science.gov (United States)

    Petrigliano, Frank A; Suero, Eduardo M; Voos, James E; Pearle, Andrew D; Allen, Answorth A

    2012-06-01

    Proximal tibial slope has been shown to influence anteroposterior translation and tibial resting point in the posterior cruciate ligament (PCL)-deficient knee. The effect of proximal tibial slope on rotational stability of the knee is unknown. Change in proximal tibial slope produced via osteotomy can influence both static translation and dynamic rotational kinematics in the PCL/posterolateral corner (PLC)-deficient knee. Controlled laboratory study. Posterior drawer, dial, and mechanized reverse pivot-shift (RPS) tests were performed on hip-to-toe specimens and translation of the lateral and medial compartments measured utilizing navigation (n = 10). The PCL and structures of the PLC were then sectioned. Stability testing was repeated, and compartmental translation was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5° or -5° of tibial slope variation, after which stability testing was repeated (n = 10). Analysis was performed using 1-way analysis of variance (ANOVA; α = .05). Combined sectioning of the PCL and PLC structures resulted in a 10.5-mm increase in the posterior drawer, 15.5-mm increase in the dial test at 30°, 14.5-mm increase in the dial test at 90°, and 17.9-mm increase in the RPS (vs intact; P slope (high tibial osteotomy [HTO] +5°) in the PCL/PLC-deficient knee reduced medial compartment translation by 3.3 mm during posterior drawer (vs deficient; P slope (HTO -5°) caused a 4.8-mm increase in medial compartment translation (vs deficient state; P slope diminished static posterior instability of the PCL/PLC-deficient knee as measured by the posterior drawer test but had little effect on rotational or dynamic multiplanar stability as assessed by the dial and RPS tests, respectively. Conversely, decreasing posterior slope resulted in increased posterior instability and a significant increase in the magnitude of the RPS. These results suggest that increasing posterior tibial slope may improve

  16. Diagnostic nerve ultrasonography

    International Nuclear Information System (INIS)

    Baeumer, T.; Grimm, A.; Schelle, T.

    2017-01-01

    For the diagnostics of nerve lesions an imaging method is necessary to visualize peripheral nerves and their surrounding structures for an etiological classification. Clinical neurological and electrophysiological investigations provide functional information about nerve lesions. The information provided by a standard magnetic resonance imaging (MRI) examination is inadequate for peripheral nerve diagnostics; however, MRI neurography is suitable but on the other hand a resource and time-consuming method. Using ultrasonography for peripheral nerve diagnostics. With ultrasonography reliable diagnostics of entrapment neuropathies and traumatic nerve lesions are possible. The use of ultrasonography for neuropathies shows that a differentiation between different forms is possible. Nerve ultrasonography is an established diagnostic tool. In addition to the clinical examination and clinical electrophysiology, structural information can be obtained, which results in a clear improvement in the diagnostics. Ultrasonography has become an integral part of the diagnostic work-up of peripheral nerve lesions in neurophysiological departments. Nerve ultrasonography is recommended for the diagnostic work-up of peripheral nerve lesions in addition to clinical and electrophysiological investigations. It should be used in the clinical work-up of entrapment neuropathies, traumatic nerve lesions and spacy-occupying lesions of nerves. (orig.) [de

  17. Nerve ultrasound shows subclinical peripheral nerve involvement in neurofibromatosis type 2.

    Science.gov (United States)

    Telleman, Johan A; Stellingwerff, Menno D; Brekelmans, Geert J; Visser, Leo H

    2018-02-01

    Neurofibromatosis type 2 (NF2) is mainly associated with central nervous system (CNS) tumors. Peripheral nerve involvement is described in symptomatic patients, but evidence of subclinical peripheral nerve involvement is scarce. We conducted a cross-sectional pilot study in 2 asymptomatic and 3 minimally symptomatic patients with NF2 to detect subclinical peripheral nerve involvement. Patients underwent clinical examination, nerve conduction studies (NCS), and high-resolution ultrasonography (HRUS). A total of 30 schwannomas were found, divided over 20 nerve segments (33.9% of all investigated nerve segments). All patients had at least 1 schwannoma. Schwannomas were identified with HRUS in 37% of clinically unaffected nerve segments and 50% of nerve segments with normal NCS findings. HRUS shows frequent subclinical peripheral nerve involvement in NF2. Clinicians should consider peripheral nerve involvement as a cause of weakness and sensory loss in the extremities in patients with this disease. Muscle Nerve 57: 312-316, 2018. © 2017 Wiley Periodicals, Inc.

  18. Do Capacitively Coupled Electric Fields Accelerate Tibial Stress Fracture Healing

    National Research Council Canada - National Science Library

    Hoffman, Andrew

    2002-01-01

    A convenience sample based on availability of tibial stress fracture cases at local Sports Medicine Clinics will be selected over 2-3 years until forty subjects (20 male, 20 female) have been treated...

  19. Do Capacitively Coupled Electric Fields Accelerate Tibial Stress Fracture Healing

    National Research Council Canada - National Science Library

    Hoffman, Andrew

    2003-01-01

    A convenience sample based on availability of tibial stress fracture cases at local Sports Medicine Clinics will be selected over 2-3 years until forty subjects (20 male, 20 female) have been treated...

  20. Preliminary evaluation of the tibial tuberosity-trochlear groove measurement

    DEFF Research Database (Denmark)

    Miles, James Edward; Kirpensteijn, Jolle; Svalastoga, Eiliv Lars

    guide surgical treatment. The TTTG measures tibial tuberosity position relative to the axis of the femoral trochlea. A preliminary investigation of TTTG measurement was performed using the red fox (Vulpes vulpes) cadavers as a morphologically similar and homogenous substitute for dog cadavers. CT...

  1. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    OpenAIRE

    Tanikake, Yohei; Hayashi, Koji; Ogawa, Munehiro; Inagaki, Yusuke; Kawate, Kenji; Tomita, Tetsuya; Tanaka, Yasuhito

    2016-01-01

    A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed...

  2. Aetiology and mechanisms of injury in medial tibial stress syndrome: Current and future developments

    OpenAIRE

    Franklyn, Melanie; Oakes, Barry

    2015-01-01

    Medial tibial stress syndrome (MTSS) is a debilitating overuse injury of the tibia sustained by individuals who perform recurrent impact exercise such as athletes and military recruits. Characterised by diffuse tibial anteromedial or posteromedial surface subcutaneous periostitis, in most cases it is also an injury involving underlying cortical bone microtrauma, although it is not clear if the soft tissue or cortical bone reaction occurs first. Nuclear bone scans and magnetic resonance imagin...

  3. Anterior avulsion fracture of the tibial tuberosity in adolescents - Two case reports

    Directory of Open Access Journals (Sweden)

    Aleilimar Teixeira da Silva Júnior

    Full Text Available ABSTRACT The objective here was to report two rare cases of anterior avulsion fracture of the tibial tuberosity in adolescents. Case 1 was a 15-year-old male who became injured through landing on his left knee and presented limited extension. Case 2 was a 16-year-old basketball player who presented sudden pain in the right knee and functional incapacity, after a jump. Imaging examinations (radiographs and computed tomography showed anterior avulsion fractures of the tibial tuberosity. Surgical fixation was performed using screws and anchors, while avoiding growth plate injury. The cases evolved without lower-limb deformities.

  4. Anterior referencing of tibial slope in total knee arthroplasty considerably influences knee kinematics : a musculoskeletal simulation study

    NARCIS (Netherlands)

    Marra, Marco Antonio; Strzelczak, Marta; Heesterbeek, Petra J.C.; van de Groes, Sebastiaan A.W.; Janssen, Dennis W.; Koopman, Bart F.J.M.; Wymenga, Ate B.; Verdonschot, Nico J.J.

    2017-01-01

    Purpose: In total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior

  5. Patella height changes post high tibial osteotomy

    Directory of Open Access Journals (Sweden)

    Siew Ghim Gooi

    2017-01-01

    Full Text Available Background: Medial opening wedge high tibial osteotomy (HTO is a well-described treatment in early medial compartmental osteoarthritis of the knee. However, two undesirable sequelae may follow –patella baja and changes in the posterior tibial slope (TS. Materials and Methods: We conducted a retrospective study in patients who underwent HTO in our center between September 2009 and February 2017. Preoperative and 6-week postoperative long-leg weight bearing films and lateral knee radiographs were assessed. Pre- and postoperative radiological measurements include the Caton-Deschamps Index (CDI, the mechanical axis deviation (MAD, and the posterior TS. Independant t-test and Pearson correlation test were performed. Results: A total of 106 knees were recruited. The mean age was 48.8 ± 10.8 years. 66 (62.3% and 40 (37.7% knees were from males and females, respectively. The mean pre- and postoperative measurements was (−9.70° ± 3.67° to 0.08° ± 2.80° (−varus; +valgus for the MAD, (7.14° ± 1.78° to 8.72° ± 3.11° for posterior TS, and (0.93° ± 0.084° to 0.82° ± 0.13° for CDI (P ≤ 0.001 for all. The association between patella height change and the level of osteotomy (supra-tubercle vs. infra-tubercle was statistically significant (P < 0.001. A supra-tubercle osteotomy cut significantly lowering patella height (P = 0.011. There was otherwise no statistically significant correlations between patella height changes and the correction angle (P = 0.187 or posterior TS change (P = 0.744. Conclusions: A medial opening wedge HTO above the tibial tubercle was significantly associated with lowering patella height or reducing CDI postoperatively. Based on our results, we would recommend the use of an infra-tubercle osteotomy during the corrective surgery to prevent the complication of patella baja.

  6. Fracture of a Polyethylene Tibial Post in a Scorpio Posterior-Stabilized Knee Prosthesis

    OpenAIRE

    Lim, Hong Chul; Bae, Ji Hoon; Hwang, Jin Ho; Kim, Seung Joo; Yoon, Ji Yeol

    2009-01-01

    We report the case of a polyethylene tibial post fracture in a 72-year-old woman 14 months after a Scorpio posterior-stabilized (PS) total knee arthroplasty. The polyethylene wear was found around the fracture site of the post, especially over the anterior aspect of the post base. The failure mechanism of the post fracture in the present case was anterior impingement with excessive wear over the base of the anterior aspect of the tibial post, which became a stress-riser of post and cam articu...

  7. Polymeric Nerve Conduits with Contact Guidance Cues Used in Nerve Repair

    Institute of Scientific and Technical Information of China (English)

    G DAI; X NIU; J YIN

    2016-01-01

    In the modern life, the nerve injury frequently happens due to mechanical, chemical or thermal accidents. In the trivial injuries, the peripheral nerves can regenerate on their own; however, in most of the cases the clinical treatments are required, where relatively large nerve injury gaps are formed. Currently, the nerve repair can be accomplished by direct suture when the injury gap is not too large;while the autologous nerve graft working as the gold standard of peripheral nerve injury treatment for nerve injuries with larger gaps. However, the direct suture is limited by heavy tension at the suture sites, and the autologous nerve graft also has the drawbacks of donor site morbidity and insufifcient donor tissue. Recently, artiifcial nerve conduits have been developed as an alternative for clinical nerve repair to overcome the limitations associated with the above treatments. In order to further improve the efifciency of nerve conduits, various guidance cues are incorporated, including physical cues, biochemical signals, as well as support cells. First, this paper reviewed the contact guidance cues applied in nerve conduits, such as lumen ifllers, multi-channels and micro-patterns on the inner surface. Then, the paper focused on the polymeric nerve conduits with micro inner grooves. The polymeric nerve conduits were fabricated using the phase inversion-based ifber spinning techniques. The smart spinneret with grooved die was designed in the spinning platform, while different spinning conditions, including flow rates, air-gap distances, and polymer concentrations, were adjusted to investigate the inlfuence of fabrication conditions on the geometry of nerve conduits. The inner groove size in the nerve conduits can be precisely controlled in our hollow ifber spinning process, which can work as the efifcient contact guidance cue for nerve regeneration.

  8. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  9. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  10. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP

    Directory of Open Access Journals (Sweden)

    Chandra Sekharam Naidu

    2015-05-01

    Full Text Available INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures were deemed not amenable for surgical reconstruction . 2 Conservative treatment by POP cast l ead to prolonged immobilization, leading to ankle and knee stiffness affecting quality of life of the patient . 3 Operative treatment is indicated for most tibial fractures caused by high energy trauma. Operative treatment allows early motion, and avoids sho rtening and other complications associated with prolonged immobilization . 4 The fundamental goal of treatment of distal tibial fractures is restoration of normal or near normal alignment and articular congruity and finally to obtain a well healed fracture; pain free weight bearing ; and functional ROM of ankle joint. For the past decade, plating has been successful in treating complex fractures of the lower extremity especially distal tibia . 5 Conventional ORIF have been associated with complications like infe ction and delayed or non - union due to devitalisation of bony fragments and additional damage to the soft tissues . 6 To improve fracture healing, more “biological” methods have been developed in the last decade to lessen the surgical dissection, preserving b lood supply to bony fragments and containing at least partially the fracture haematoma . 7 Recently, the trend is towards use of a Locking compression plate for treatment of fractures of the distal part of the tibia 8 . Compared with a conventional plate, a Lo cking compression plate imparts a higher degree of stability and provides better protection against primary and secondary losses of reduction and minimization of bone

  11. Tissue-engineered spiral nerve guidance conduit for peripheral nerve regeneration.

    Science.gov (United States)

    Chang, Wei; Shah, Munish B; Lee, Paul; Yu, Xiaojun

    2018-06-01

    Recently in peripheral nerve regeneration, preclinical studies have shown that the use of nerve guidance conduits (NGCs) with multiple longitudinally channels and intra-luminal topography enhance the functional outcomes when bridging a nerve gap caused by traumatic injury. These features not only provide guidance cues for regenerating nerve, but also become the essential approaches for developing a novel NGC. In this study, a novel spiral NGC with aligned nanofibers and wrapped with an outer nanofibrous tube was first developed and investigated. Using the common rat sciatic 10-mm nerve defect model, the in vivo study showed that a novel spiral NGC (with and without inner nanofibers) increased the successful rate of nerve regeneration after 6 weeks recovery. Substantial improvements in nerve regeneration were achieved by combining the spiral NGC with inner nanofibers and outer nanofibrous tube, based on the results of walking track analysis, electrophysiology, nerve histological assessment, and gastrocnemius muscle measurement. This demonstrated that the novel spiral NGC with inner aligned nanofibers and wrapped with an outer nanofibrous tube provided a better environment for peripheral nerve regeneration than standard tubular NGCs. Results from this study will benefit for future NGC design to optimize tissue-engineering strategies for peripheral nerve regeneration. We developed a novel spiral nerve guidance conduit (NGC) with coated aligned nanofibers. The spiral structure increases surface area by 4.5 fold relative to a tubular NGC. Furthermore, the aligned nanofibers was coated on the spiral walls, providing cues for guiding neurite extension. Finally, the outside of spiral NGC was wrapped with randomly nanofibers to enhance mechanical strength that can stabilize the spiral NGC. Our nerve histological data have shown that the spiral NGC had 50% more myelinated axons than a tubular structure for nerve regeneration across a 10 mm gap in a rat sciatic nerve

  12. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    Science.gov (United States)

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P  .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P  0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  13. Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.

    Science.gov (United States)

    Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao

    2017-12-01

    The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.

  14. The arthroscopic treatment of displaced tibial spine fractures in children and adolescents using Meniscus Arrows(A (R))

    NARCIS (Netherlands)

    Wouters, Diederick B.; de Graaf, Joost S.; Hemmer, Patrick H.; Burgerhof, Johannes G. M.; Kramer, William L. M.

    This article summarises the results of a newly developed technique that utilises Meniscus Arrows(A (R)) for the arthroscopic fixation of displaced tibial spine fractures in children and adolescents. Twelve tibial spine fractures in the knees of eleven children between 6 and 15 years old, with an

  15. Sensation, mechanoreceptor, and nerve fiber function after nerve regeneration

    DEFF Research Database (Denmark)

    Krarup, Christian; Rosén, Birgitta; Boeckstyns, Michel

    2017-01-01

    Objective: Sensation is essential for recovery after peripheral nerve injury. However, the relationship between sensory modalities and function of regenerated fibers is uncertain. We have investigated the relationships between touch threshold, tactile gnosis, and mechanoreceptor and sensory fiber...... function after nerve regeneration. Methods: Twenty-one median or ulnar nerve lesions were repaired by a collagen nerve conduit or direct suture. Quantitative sensory hand function and sensory conduction studies by near-nerve technique, including tactile stimulation of mechanoreceptors, were followed for 2...... years, and results were compared to noninjured hands. Results: At both repair methods, touch thresholds at the finger tips recovered to 81 ± 3% and tactile gnosis only to 20 ± 4% (p nerve action potentials (SNAPs) remained dispersed and areas recovered to 23 ± 2...

  16. Inverse relationship between the complexity of midfoot kinematics and muscle activation in patients with medial tibial stress syndrome

    DEFF Research Database (Denmark)

    Rathleff, M S; Samani, Afshin; Olesen, C G

    2011-01-01

    Medial tibial stress syndrome is a common overuse injury characterized by pain located on the medial side of the lower leg during weight bearing activities such as gait. The purpose of this study was to apply linear and nonlinear methods to compare the structure of variability of midfoot kinematics...... and surface electromyographic (SEMG) signals between patients with medial tibial stress syndrome and healthy controls during gait. Fourteen patients diagnosed with medial tibial stress syndrome and 11 healthy controls were included from an orthopaedic clinic. SEMG from tibialis anterior and the soleus muscles...... as well as midfoot kinematics were recorded during 20 consecutive gait cycles. Permuted sample entropy and permutation entropy were used as a measure of complexity from SEMG signals and kinematics. SEMG signals in patients with medial tibial stress syndrome were characterized by higher structural...

  17. The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints.

    Science.gov (United States)

    Sanders, Anthony P; Raeymaekers, Bart

    2014-10-01

    A prosthetic knee joint typically comprises a cobalt-chromium femoral component that articulates with a polyethylene tibial insert. A locking screw may be used to prevent micromotion and dislodgement of the tibial insert from the tibial tray. Screw loosening and back-out have been reported, but the mechanism that causes screw loosening is currently not well understood. In this paper, we experimentally evaluate the effect of polyethylene creep on the preload of the locking screw. We find that the preload decreases significantly as a result of polyethylene creep, which reduces the torque required to loosen the locking screw. The torque applied to the tibial insert due to internal/external rotation within the knee joint during gait could thus drive locking screw loosening and back-out. The results are very similar for different types of polyethylene. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Arthroscopic treatment of displaced tibial eminence fractures using a suspensory fixation

    Directory of Open Access Journals (Sweden)

    Philippe Loriaut

    2017-01-01

    Conclusion: The arthroscopic treatment of displaced tibial intercondylar eminence fractures using a suspensory system provided a satisfactory clinical and radiological outcome at a followup of 2 years.

  19. The role of great auricular-facial nerve neurorrhaphy in facial nerve damage

    OpenAIRE

    Sun, Yan; Liu, Limei; Han, Yuechen; Xu, Lei; Zhang, Daogong; Wang, Haibo

    2015-01-01

    Background: Facial nerve is easy to be damaged, and there are many reconstructive methods for facial nerve reconstructive, such as facial nerve end to end anastomosis, the great auricular nerve graft, the sural nerve graft, or hypoglossal-facial nerve anastomosis. However, there is still little study about great auricular-facial nerve neurorrhaphy. The aim of the present study was to identify the role of great auricular-facial nerve neurorrhaphy and the mechanism. Methods: Rat models of facia...

  20. The role of great auricular-facial nerve neurorrhaphy in facial nerve damage.

    Science.gov (United States)

    Sun, Yan; Liu, Limei; Han, Yuechen; Xu, Lei; Zhang, Daogong; Wang, Haibo

    2015-01-01

    Facial nerve is easy to be damaged, and there are many reconstructive methods for facial nerve reconstructive, such as facial nerve end to end anastomosis, the great auricular nerve graft, the sural nerve graft, or hypoglossal-facial nerve anastomosis. However, there is still little study about great auricular-facial nerve neurorrhaphy. The aim of the present study was to identify the role of great auricular-facial nerve neurorrhaphy and the mechanism. Rat models of facial nerve cut (FC), facial nerve end to end anastomosis (FF), facial-great auricular neurorrhaphy (FG), and control (Ctrl) were established. Apex nasi amesiality observation, electrophysiology and immunofluorescence assays were employed to investigate the function and mechanism. In apex nasi amesiality observation, it was found apex nasi amesiality of FG group was partly recovered. Additionally, electrophysiology and immunofluorescence assays revealed that facial-great auricular neurorrhaphy could transfer nerve impulse and express AChR which was better than facial nerve cut and worse than facial nerve end to end anastomosis. The present study indicated that great auricular-facial nerve neurorrhaphy is a substantial solution for facial lesion repair, as it is efficiently preventing facial muscles atrophy by generating neurotransmitter like ACh.

  1. Pinched Nerve

    Science.gov (United States)

    ... You are here Home » Disorders » All Disorders Pinched Nerve Information Page Pinched Nerve Information Page What research is being done? Within the NINDS research programs, pinched nerves are addressed primarily through studies associated with pain ...

  2. Sepsis National Hospital Inpatient Quality Measure (SEP-1): Multistakeholder Work Group Recommendations for Appropriate Antibiotics for the Treatment of Sepsis.

    Science.gov (United States)

    Septimus, Edward J; Coopersmith, Craig M; Whittle, Jessica; Hale, Caleb P; Fishman, Neil O; Kim, Thomas J

    2017-10-16

    The Center for Medicare and Medicaid Services adopted the Early Management Bundle, Severe Sepsis/Septic Shock (SEP-1) performance measure to the Hospital Inpatient Quality Reporting Program in July 2015 to help address the high mortality and high cost associated with sepsis. The SEP-1 performance measure requires, among other critical interventions, timely administration of antibiotics to patients with sepsis or septic shock. The multistakeholder workgroup recognizes the need for SEP-1 but strongly believes that multiple antibiotics listed in the antibiotic tables for SEP-1 are not appropriate and the use of these antibiotics, as called for in the SEP-1 measure, is not in alignment with prudent antimicrobial stewardship. To promote the appropriate use of antimicrobials and combat antimicrobial resistance, the workgroup provides recommendations for appropriate antibiotics for the treatment of sepsis. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  3. MRI signal-based quantification of subchondral bone at the tibial plateau: a population study

    Energy Technology Data Exchange (ETDEWEB)

    MacKay, James W. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Norfolk and Norwich University Hospital, Radiology Academy, Cotman Centre, Norwich (United Kingdom); Godley, Keith C.; Toms, Andoni P. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom)

    2014-11-15

    To determine whether differences in subchondral sclerosis at the tibial plateau could be detected with magnetic resonance (MR) imaging in two different age groups. This was a retrospective hypothesis-testing study. Thirty-two knees in group A (25-30 year olds) and 32 knees in group B (45-50 years old) were included. Participants had no MR features of osteoarthritis (OA). On coronal images, tibial articular cartilage thickness was measured, and regions of interest were created in the medial and lateral tibial plateau subchondral bone and in the tibial metaphysis. The measure of heterogeneity at the tibial plateaux was the ratio of the standard deviation of the signal in the medial/lateral compartment to the standard deviation of the signal in the metaphysis (ratio of standard deviations - RSS{sub medial}/RSS{sub lateral}). Differences between groups were assessed using unpaired Student's t-tests. Mean RSS{sub medial} was 2.61 (standard deviation, SD = 0.77) in group A and 2.97 (SD = 0.59) in group B. Mean RSS{sub lateral} in group A was 1.86 (SD = 0.63) and 1.89 (SD = 0.43) in group B. Mean total cartilage thickness (in mm) in group A was 3.38 (SD = 0.90) for the medial and 3.90 (SD = 1.09) for the lateral compartment and 3.44 (SD = 0.74) for the medial and 3.96 (SD = 0.96) for the lateral compartment in group B. The only parameter to show a statistically significant difference between groups was RSS{sub medial} (p = 0.04). A difference in medial subchondral bone sclerosis between two age groups was demonstrated in the absence of MR features of OA. This may represent the earliest OA change detectable on MR imaging. (orig.)

  4. Posterior tibial tendon dysfunction by bone imprisonment | Zejjari ...

    African Journals Online (AJOL)

    The posterior tibial muscle is the main functional support of the plantar arch its dysfunction is the main cause of acquired flat foot. This is a 32 year old patient who consults for progressive pain of the inside of the ankle and right foot with a considerable decrease in its sporting and professional activity. Examination reveals a ...

  5. Pulsed radiofrequency of the composite nerve supply to the knee joint as a new technique for relieving osteoarthritic pain: a preliminary report.

    Science.gov (United States)

    Vas, Lakshmi; Pai, Renuka; Khandagale, Nishigandha; Pattnaik, Manorama

    2014-01-01

    We report a new technique for pulsed radiofrequency (PRF) of the entire nerve supply of the knee as an option in treating osteoarthritis (OA) of knee. We targeted both sensory and motor nerves supplying all the structures around the knee: joint, muscles, and skin to address the entire nociception and stiffness leading to peripheral and central sensitization in osteoarthritis. Ten patients with pain, stiffness, and loss of function in both knees were treated with ultrasonography (USG) guided PRF of saphenous, tibial, and common peroneal nerves along with subsartorial, peripatellar, and popliteal plexuses. USG guided PRF of the femoral nerve was also done to address the innervation of the quadriceps muscle. Assessment of pain (Numerical Rating Scale [NRS], pain DETECT, knee function [Western Ontario and McMaster Universities Osteoarthritis Index- WOMAC]) were documented pre and post PRF at 3 and 6 months. Knee radiographs (Kellgren-Lawrence [K-L] grading) were done before PRF and one week later. All the patients showed a sustained improvement of NRS, pain DETECT, and WOMAC at 3 and 6 months. The significant improvement of patellar position and tibio-femoral joint space was concordant with the patient's reporting of improvement in stiffness and pain. The sustained pain relief and muscle relaxation enabled the patients to optimize physiotherapy thereby improving endurance training to include the daily activities of life. We conclude that OA knee pain is a product of neuromyopathy and that PRF of the sensory and motor nerves appeared to be a safe, effective, and minimally invasive technique. The reduction of pain and stiffness improved the knee function and probably reduced the peripheral and central sensitization.

  6. Assessment of nerve regeneration across nerve allografts treated with tacrolimus.

    Science.gov (United States)

    Haisheng, Han; Songjie, Zuo; Xin, Li

    2008-01-01

    Although regeneration of nerve allotransplant is a major concern in the clinic, there have been few papers quantitatively assessing functional recovery of animals' nerve allografts in the long term. In this study, functional recovery, histopathological study, and immunohistochemistry changes of rat nerve allograft with FK506 were investigated up to 12 weeks without slaughtering. C57 and SD rats were used for transplantation. The donor's nerve was sliced and transplanted into the recipient. The sciatic nerve was epineurally sutured with 10-0 nylon. In total, 30 models of transplantation were performed and divided into 3 groups that were either treated with FK506 or not. Functional recovery of the grafted nerve was serially assessed by the pin click test, walking track analysis and electrophysiological evaluations. A histopathological study and immunohistochemistry study were done in the all of the models. Nerve allografts treated with FK506 have no immune rejection through 12 weeks. Sensibility had similarly improved in both isografts and allografts. There has been no difference in each graft. Walk track analysis demonstrates significant recovery of motor function of the nerve graft. No histological results of difference were found up to 12 weeks in each graft. In the rodent nerve graft model, FK506 prevented nerve allograft rejection across a major histocompatibility barrier. Sensory recovery seems to be superior to motor function. Nerve isograft and allograft treated with FK506 have no significant difference in function recovery, histopathological result, and immunohistochemistry changes.

  7. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  8. Fixator-assisted medial tibial plateau elevation to treat severe Blount's disease: outcomes at maturity.

    Science.gov (United States)

    Fitoussi, F; Ilharreborde, B; Lefevre, Y; Souchet, P; Presedo, A; Mazda, K; Penneçot, G F

    2011-04-01

    Severe forms of Blount's disease may be associated with medial tibial plateau (MTP) depression. Management should then take account of joint congruence, laxity, limb axis, torsional abnomality, leg length discrepancy (LLD) and eventual recurrence history. Eight knees (six patients) were managed in a single step comprising MTP elevation osteotomy, lateral epiphysiodesis and proximal tibia osteotomy to correct varus and rotational deformity. Fixation was achieved using an Ilizarov external fixator. Mean age was 10.5 years. Mean hip-knee-ankle (HKA) angle was 151°; distal femoral varus, 94°; metaphyseal-diaphyseal angle (MDA), 27°; and angle of depression of the medial tibial plateau (ADMTP), 42°. Predicted residual proximal tibial growth was 2.6 cm. At a mean 48 months' follow-up, results were good in six cases, medium in one and poor (due to incomplete lateral epiphysiodesis) in one. Mean lateral tibial torsion was 9° and final LLD 11 mm. Weight-bearing was resumed at 2 months, and the fixator was removed at 5.5 months postoperatively. At end of follow-up, mean HKA angle was 179.6°, MDA 7.3° and ADMTP 5.4°. This technically demanding procedure gave satisfactory results in terms of axes and congruence; longer term assessment remains needed. Level IV. Retrospective study. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  9. Peripheral nerve regeneration through P(DLLA-epsilon-CL) nerve guides

    NARCIS (Netherlands)

    Den Dunnen, WFA; Meek, MF; Robinson, PH; Schakernraad, JM

    1998-01-01

    P(DLLA-epsilon-CL) nerve guides can be used perfectly for short nerve gaps in rats, and are even better than short autologous nerve grafts. The tube dimensions, such as the internal diameter and wall thickness, are very important for the final outcome of peripheral nerve regeneration, as well as the

  10. Characterization of SEP events at high heliographic latitudes

    International Nuclear Information System (INIS)

    Dalla, S.; Balogh, A.; Krucker, S.; Posner, A.; Mueller-Mellin, R.; Anglin, J.D.; Hofer, M.Y.; Marsden, R.G.; Sanderson, T.R.; Heber, B.; Zhang, M.; McKibben, R.B.

    2003-01-01

    Between February 2000 and May 2002, the Ulysses spacecraft made the first ever measurements of solar energetic particles (SEPs) at high heliographic latitudes. Nine large gradual SEP events were detected at latitudes greater than 45 deg., their signatures being clearest at high particle energies, i.e. protons >30 MeV and electrons >0.1 MeV. In this paper we measure the onset times of Ulysses high latitude events in several energy channels, and plot them versus inverse particle speed. We repeat the procedure for near Earth observations by Wind and SOHO. Velocity dispersion is observed in all the events near Earth and in most of them at Ulysses. The plots of onset times versus inverse speed allow to derive an experimental path length and time of release from the solar atmosphere. We find that the derived path lengths at Ulysses are longer than the length of a Parker spiral magnetic field line connecting it to the Sun, by a factor between 1.2-2.7. The time of particle release from the Sun is typically between 100 and 200 mins later than the release time derived from in-ecliptic measurements. Unlike near Earth observations, Ulysses measurements are therefore not compatible with scatter-free propagation from the Sun to the spacecraft

  11. Spatiotemporal dynamics of re-innervation and hyperinnervation patterns by uninjured CGRP fibers in the rat foot sole epidermis after nerve injury

    Directory of Open Access Journals (Sweden)

    Duraku Liron S

    2012-08-01

    Full Text Available Abstract The epidermis is innervated by fine nerve endings that are important in mediating nociceptive stimuli. However, their precise role in neuropathic pain is still controversial. Here, we have studied the role of epidermal peptidergic nociceptive fibers that are located adjacent to injured fibers in a rat model of neuropathic pain. Using the Spared Nerve Injury (SNI model, which involves complete transections of the tibial and common peroneal nerve while sparing the sural and saphenous branches, mechanical hypersensitivity was induced of the uninjured lateral (sural and medial (saphenous area of the foot sole. At different time points, a complete foot sole biopsy was taken from the injured paw and processed for Calcitonin Gene-Related Peptide (CGRP immunohistochemistry. Subsequently, a novel 2D-reconstruction model depicting the density of CGRP fibers was made to evaluate the course of denervation and re-innervation by uninjured CGRP fibers. The results show an increased density of uninjured CGRP-IR epidermal fibers on the lateral and medial side after a SNI procedure at 5 and 10 weeks. Furthermore, although in control animals the density of epidermal CGRP-IR fibers in the footpads was lower compared to the surrounding skin of the foot, 10 weeks after the SNI procedure, the initially denervated footpads displayed a hyper-innervation. These data support the idea that uninjured fibers may play a considerable role in development and maintenance of neuropathic pain and that it is important to take larger biopsies to test the relationship between innervation of injured and uninjured nerve areas.

  12. Improvement of the knee center of rotation during walking after opening wedge high tibial osteotomy.

    Science.gov (United States)

    Kim, Kyungsoo; Feng, Jun; Nha, Kyung Wook; Park, Won Man; Kim, Yoon Hyuk

    2015-06-01

    Accurate measurement of the center of rotation of the knee joint is indispensable for prediction of joint kinematics and kinetics in musculoskeletal models. However, no study has yet identified the knee center of rotations during several daily activities before and after high tibial osteotomy surgery, which is one surgical option for treating knee osteoarthritis. In this study, an estimation method for determining the knee joint center of rotation was developed by applying the optimal common shape technique and symmetrical axis of rotation approach techniques to motion-capture data and validated for typical activities (walking, squatting, climbing up stairs, walking down stairs) of 10 normal subjects. The locations of knee joint center of rotations for injured and contralateral knees of eight subjects with osteoarthritis, both before and after high tibial osteotomy surgery, were then calculated during walking. It was shown that high tibial osteotomy surgery improved the knee joint center of rotation since the center of rotations for the injured knee after high tibial osteotomy surgery were significantly closer to those of the normal healthy population. The difference between the injured and contralateral knees was also generally reduced after surgery, demonstrating increased symmetry. These results indicate that symmetry in both knees can be recovered in many cases after high tibial osteotomy surgery. Moreover, the recovery of center of rotation in the injured knee was prior to that of symmetry. This study has the potential to provide fundamental information that can be applied to understand abnormal kinematics in patients, diagnose knee joint disease, and design a novel implants for knee joint surgeries. © IMechE 2015.

  13. Partial resection of fibula in treatment of ununited tibial shaft fractures

    Directory of Open Access Journals (Sweden)

    Butt Mohd Farooq

    2006-01-01

    Full Text Available Background : In management of fracture of both tibia and fibula, intact fibula may delay union of tibial fractures. Method : Twenty five cases of ununited fractures of tibia were managed between 1997 and 2004, by partial fibulectomy done after 20 weeks after fracture and a POP cast given for 4 weeks which was changed to a PTB cast and weight bearing encouraged at the earliest. Result : All fractures united at an average time of 14 weeks (range 6 to 20 weeks after partial fibulectomy with acceptable alignment in coronal and sagittal planes. There was no neurovascular complication, limitation of joint motion or problem at the osteotomy site. Conclusion : Partial fibulectomy is a viable option in the management of tibial delayed and non-union.

  14. Aetiology, imaging and treatment of medial tibial stress syndrome

    NARCIS (Netherlands)

    Moen, M.H.

    2012-01-01

    The work contained is this thesis discusses aetiology, imaging and treatment of a common leg injury: medial tibial stress syndrome (MTSS). Although a common injury, the number of scientific articles on this topic is relatively low as is explained in chapter 1. This chapter also highlights that the

  15. Two Exceptions in the Large SEP Events of Solar Cycles 23 and 24

    Science.gov (United States)

    Thakur, N.; Gopalswamy, N.; Makela, P.; Akiyama, S.; Yashiro, S.; Xie, H.

    2016-01-01

    We discuss our findings from a survey of all large solar energetic particle (SEP) events of Solar Cycles 23 and 24, i.e. the SEP events where the intensity of greater than 10 megaelectronvolts protons observed by GOES (Geostationary Operational Environmental Satellite) was greater than 10 proton flux units. In our previous work (Gopalswamy et al. in Geophys.Res.Lett. 41, 2673, 2014) we suggested that ground level enhancements (GLEs) in Cycles 23 and 24 also produce an intensity increase in the GOES greater than 700 megaelectronvolts proton channel. Our survey, now extended to include all large SEP events of Cycle 23, confirms this to be true for all but two events: i) the GLE of 6 May 1998 (GLE57) for which GOES did not observe enhancement in greater than 700 megaelectronvolts protons intensities and ii) a high-energy SEP event of 8 November 2000, for which GOES observed greater than 700 megaelectronvolts protons but no GLE was recorded. Here we discuss these two exceptions. We compare GLE57 with other small GLEs, and the 8 November 2000 SEP event with those that showed similar intensity increases in the GOES greater than 700 megaelectronvolts protons but produced GLEs. We find that, because GOES greater than 700 megaelectronvolts proton intensity enhancements are typically small for small GLEs, they are difficult to discern near solar minima due to higher background. Our results also support that GLEs are generally observed when shocks of the associated coronal mass ejections (CMEs) form at heights 1.2-1.93 solar radii [R (sub solar)] and when the solar particle release occurs between 2-6 solar radii [R (sub solar)]. Our secondary findings support the view that the nose region of the CME-shock may be accelerating the first-arriving GLE particles and the observation of a GLE is also dependent on the latitudinal connectivity of the observer to the CME-shock nose. We conclude that the GOES greater than 700 megaelectronvolts proton channel can be used as an indicator

  16. [Physiotherapy and neurogenic lower urinary tract dysfunction in multiple sclerosis patients: a randomized controlled trial].

    Science.gov (United States)

    Gaspard, L; Tombal, B; Opsomer, R-J; Castille, Y; Van Pesch, V; Detrembleur, C

    2014-09-01

    This randomized controlled trial compare the efficacy of pelvic floor muscle training vs. transcutaneous posterior tibial nerve stimulation. Inclusion criteria were EDSS scoreurinary tract symptoms. Exclusion criteria were multiple sclerosis relapse during the study, active urinary tract infection and pregnancy. The primary outcome was quality of life (SF-Qualiveen questionnaire). Secondary outcomes included overactive bladder (USP questionnaire) score and frequency of urgency episodes (3-day bladder diary). Sample size was calculated after 18 patients were included. Data analysis was blinded. Each patient received 9 sessions of 30 minutes weekly. Patients were randomized in pelvic floor muscles exercises with biofeedback group (muscle endurance and relaxation) or transcutaneous posterior tibial nerve stimulation group (rectangular alternative biphasic current with low frequency). A total of 31 patients were included. No difference appeared between groups for quality of life, overactive bladder and frequency of urgency episodes (respectively P=0.197, P=0.532 et P=0.788). These parameters were significantly improved in pelvic floor muscle training group (n=16) (respectively P=0.004, P=0.002 et P=0.006) and in transcutaneous posterior tibial nerve stimulation group (n=15) (respectively P=0.001, P=0.001 et P=0.031). Pelvic floor muscle training and transcutaneous posterior tibial nerve stimulation improved in the same way symptoms related to urgency in MS patients with mild disability. 2. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Etiologic factors in the development of medial tibial stress syndrome: a review of the literature.

    Science.gov (United States)

    Tweed, Jo L; Avil, Steven J; Campbell, Jackie A; Barnes, Mike R

    2008-01-01

    Medial tibial stress syndrome is a type of exercise-induced leg pain that is common in recreational and competitive athletes. Although various studies have attempted to find the exact pathogenesis of this common condition, it remains unknown. Various theories in literature from 1976 to 2006 were reviewed using key words. Until recently, inflammation of the periosteum due to excessive traction was thought to be the most likely cause of medial tibial stress syndrome. This periostitis has been hypothesized by some authors to be caused by the tearing away of the muscle fibers at the muscle-bone interface, although there are several suggestions as to which, if any, muscle is responsible. Recent studies have supported the view that medial tibial stress syndrome is not an inflammatory process of the periosteum but instead a stress reaction of bone that has become painful.

  18. Application of the chronic constriction injury of the partial sciatic nerve model to assess acupuncture analgesia

    Directory of Open Access Journals (Sweden)

    Zhi MJ

    2017-09-01

    Full Text Available Mu-Jun Zhi,1,2,* Kun Liu,1,* Zhou-Li Zheng,1,3 Xun He,1 Tie Li,2 Guang Sun,1,2 Meng Zhang,4 Fu-Chun Wang,2 Xin-Yan Gao,1 Bing Zhu1 1Department of Physiology, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Sciences, Beijing, People’s Republic of China; 2College of Acupuncture and Moxibustion, Changchun University of Chinese Medicine, Changchun, People’s Republic of China; 3College of Acupuncture and Moxibution, Shaanxi University of Chinese Medicine, People’s Republic of China; 4Department of Chinese Medicine, Dongli Hospital of Traditional Chinese Medicine, Tianjin, People’s Republic of China *These authors contributed equally to this work Purpose: To validate and explore the application of a rat model of chronic constriction injury to the partial sciatic nerve in investigation of acupuncture analgesia.Methods: Chronic constriction injury of the sciatic nerve (CCI and chronic constriction injury of the partial sciatic nerve (CCIp models were generated by ligating either the sciatic nerve trunk or its branches in rats. Both models were evaluated via paw mechanical withdrawal latency (PMWL, paw mechanical withdrawal threshold (PMWT, nociceptive reflex-induced electromyogram (C-fiber reflex EMG, and dorsal root ganglion immunohistochemistry. Electroacupuncture (EA was performed at GB30 to study the analgesic effects on neuropathic pain and the underlying mechanisms.Results: Following ligation of the common peroneal and tibial nerves, CCIp rats exhibited hindlimb dysfunction, hind paw shrinkage and lameness, mirroring those of CCI rats (generated by ligating the sciatic nerve trunk. Compared to presurgery measurements, CCIp and CCI modeling significantly decreased the PMWL and PMWT. EA at GB30 increased the PMWL and PMWT in both CCI and CCIp rats. Calcitonin gene-related polypeptide and substance P expressions were apparently increased in both CCI and CCIp groups, but were not different from each other. The C

  19. Combined SEP and anti-PD-L1 antibody produces a synergistic antitumor effect in B16-F10 melanoma-bearing mice.

    Science.gov (United States)

    Hu, Zhengping; Ye, Liang; Xing, Yingying; Hu, Jinhang; Xi, Tao

    2018-01-09

    The increased PD-L1 induces poorer prognosis in melanoma. The treatment with PD-1/PD-L1 antibodies have a low response rate. The combination immunotherapies are the encouraging drug development strategy to receive maximal therapeutic benefit. In this study, we investigated the enhanced antitumor and immunomodulatory activity of combined SEP and αPD-L1 in B16-F10 melanoma-bearing mice. The results shown that combined SEP and αPD-L1 presented significant synergistic antitumor effects, increased the frequency of CD8 + and CD4 + T cells in spleen and tumor, cytotoxic activity of CTL in spleen, and IL-2 and IFN-γ levels in splenocytes and tumor. The combination treatment also produced synergistic increase in P-ERK1/2 level in spleen. Immunohistochemistry shown that SEP induced the PD-L1 expression in melanoma tissue possibly by promoting IFN-γ excretion, which led to the synergistic anti-tumor effects of aPD-L1 and SEP. Furthermore, in the purified T lymphocyte from the naive mice, the combination of SEP and αPD-L1 had more potent than SEP or αPD-L1 in promoting T lymphocyte proliferation and cytokines secretion including IL-2 and IFN-γ, at least partially by activating MEK/ERK pathway. Our study provides the scientific basis for a clinical trial that would involve combination of anti-PD-L1 mAb and SEP for sustained melanoma control.

  20. 630.pdf | sep102009 | currsci | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; currsci; sep102009; 630.pdf. 404! error. The page your are looking for can not be found! Please check the link or use the navigation bar at the top. YouTube; Twitter; Facebook; Blog. Academy News. IAS Logo. 29th Mid-year meeting. Posted on 19 January 2018. The 29th Mid-year meeting of the Academy will be held ...