WorldWideScience

Sample records for thyroid volume measurements

  1. Relations between various measures of iodine intake and thyroid volume, thyroid nodularity, and serum thyroglobulin

    DEFF Research Database (Denmark)

    Rasmussen, Lone Banke; Ovesen, L.; Bulow, I.

    2002-01-01

    sought to identify, if possible, groups at risk of thyroid disease because of their food choices. Design: This cohort study included 4649 randomly selected subjects with mild-to-moderate iodine deficiency; the subjects lived in 2 cities in Denmark. Iodine intake was estimated by using a food-frequency...... questionnaire and by measuring iodine excretion in spot urine samples. Thyroid volume and nodularity were measured with ultrasonography. Results: In multiple linear regression models, significant inverse relations were found between thyroid volume and estimated 24-h iodine excretion, iodine intake from diet...

  2. Measurement of thyroid volume, iodine concentration and total iodine content by CT and its clinical significance

    International Nuclear Information System (INIS)

    Nakaji, Shunsuke; Imanishi, Yoshimasa; Okamoto, Kyouko; Shinagawa, Toshihito

    2007-01-01

    Recently, Imanishi et al have developed new CT software for quantitative in vivo measurement of thyroid iodine. Using a CT system with the software, we measured volume, iodine concentration and total iodine content of thyroids in 63 controls and 435 patients with various diffuse thyroid diseases and thyroid nodules. In controls, all of them showed no difference between the sexes. Although the iodine concentration of the thyroid showed no difference among children, adults and seniles, the volume and total iodine content of the thyroid appeared smaller in children and seniles than in adults. In addition, although the volume and iodine concentration of the thyroid had two peaks in distribution, the total iodine content had almost normal distribution. Normal range of volume, iodine concentration and total iodine content in adults were 5.2-15.5 cm 3 , 0.28831-0.85919 mg/cm 3 and 2.35-11.69 mg, respectively. In thyroid nodule, there is no significant difference in volume, iodine concentration and total iodine content between benign and malignant nodules. All nodules with iodine concentration of less than 0.00007 mg/cm 3 were benign. No thyroid was higher in iodine concentration than the normal range although the thyroid was lower in 78.7% of patients with diffuse thyroid diseases. In all thyroids with increasing iodine concentration and total iodine content in medication course, thyroidal symptoms and signs were uncontrollable by the medication. In 43.8% of patients with long-period systemic diseases, the thyroid showed abnormality in any of the three. We concluded that quantitative in vivo measurement of thyroid iodine by CT could assist the diagnosis of thyroid diseases and decision of therapeutic methods. (author)

  3. Scintigraphic And Ultrasonic Determinations of Thyroid Volume

    International Nuclear Information System (INIS)

    Sarsono; Ismanto; Kunto, W; Hayati, N; Irma, S H

    1996-01-01

    A study has been done on the determination of thyroid volume by scintigraphic method in comparison to ultrasonographic technique, which involved a healthy woman volunteer, 5 women patients and a man patient with thyroid diseases. Scintigraphic examination upon the patient's thyroid was performed using a gamma camera 20 minutes following the injection of 55.5 Mbq (1.5 mCi) Tc-99m pertechnetate. A computer, with a dedicated program, coupled to the gamma camera was employed in the calculation of thyroid volume based on the scintigraphic data. Subsequent to the scintigraphic study, ultrasonographic determination of thyroid volume was then carried out. Correlation test that was applied to the outcome of the two methods of thyroid volume determination resulted in an excellent coefficient of correlation, R, which was 0.99. This showed a very good correlation between these two different techniques of thyroid volume determination

  4. Genetic and environmental influence on thyroid gland volume and thickness of thyroid isthmus: a twin study.

    Science.gov (United States)

    Tarnoki, Adam Domonkos; Tarnoki, David Laszlo; Speer, Gabor; Littvay, Levente; Bata, Pal; Garami, Zsolt; Berczi, Viktor; Karlinger, Kinga

    2015-12-01

    Decreased thyroid volume has been related to increased prevalence of thyroid cancer. One hundred and fourteen Hungarian adult twin pairs (69 monozygotic, 45 dizygotic) with or without known thyroid disorders underwent thyroid ultrasound. Thickness of the thyroid isthmus was measured at the thickest portion of the gland in the midline using electronic calipers at the time of scanning. Volume of the thyroid lobe was computed according to the following formula: thyroid height*width*depth*correction factor (0.63). Age-, sex-, body mass index- and smoking-adjusted heritability of the thickness of thyroid isthmus was 50% (95% confidence interval [CI], 35 to 66%). Neither left nor right thyroid volume showed additive genetic effects, but shared environments were 68% (95% CI, 48 to 80%) and 79% (95% CI, 72 to 87%), respectively. Magnitudes of monozygotic and dizygotic co-twin correlations were not substantially impacted by the correction of covariates of body mass index and smoking. Unshared environmental effects showed a moderate influence on dependent parameters (24-50%). Our analysis support that familial factors are important for thyroid measures in a general twin population. A larger sample size is needed to show whether this is because of common environmental (e.g. intrauterine effects, regional nutrition habits, iodine supply) or genetic effects.

  5. Reduction of thyroid volume following radioiodine therapy for functional autonomy

    International Nuclear Information System (INIS)

    Luster, M.; Jacob, M.; Thelen, M.H.; Michalowski, U.; Deutsch, U.; Reiners, C.

    1995-01-01

    In a retrospective study we evaluated the data of 112 patients who underwent radioiodine treatment for functional autonomy of the thyroid at Essen University Hospital from 1988 to 1993. Therapeutic activities of radioiodine were administered after individual determination of activity for intended radiation doses (150-300 Gy) taking into consideration autonomously functioning volume, maximum uptake, and effective half-life. The achieved dose was calculated by means of measurement of the radioiodine kinetics during therapy. Depending on the type of autonomous function of the thyroid (solitary autonomously functioning nodule, multiple autonomously functioning nodules, autonomously functioning thyroid tissue) volume reductions between 39 and 46% were found approximately 6 months after treatment. (orig.) [de

  6. Thyroid volume in hypothyroidism due to autoimmune disease follows a unimodal distribution: evidence against primary thyroid atrophy and autoimmune thyroiditis being distinct diseases

    DEFF Research Database (Denmark)

    Carlé, Allan; Pedersen, Inge Bülow; Knudsen, Nils

    2009-01-01

    CONTEXT: Primary overt autoimmune hypothyroidism is often divided into primary idiopathic hypothyroidism with thyroid atrophy (Ord's disease) and hypothyroidism with goitre (Hashimoto's disease). OBJECTIVE: The aim of the present study was to characterize the two subtypes of disease. DESIGN...... program including thyroid ultrasonography and measurements of thyroid autoantibodies. Of the 144 patients investigated (58% of all invited), 139 were compared with 556 sex-, age-, and region-matched controls from the cohort. RESULTS: Patients had lower median (11.6 ml vs. 13.5 ml, P = 0.001) and a more...... dispersed distribution of thyroid volumes compared with controls (P thyroid volume showed a Gaussian distribution in both males and females with no bimodal pattern. Nearly all patients had measurable thyroid autoantibodies, but with increasing thyroid volume (quartile I, II, III, and IV...

  7. Determination of the autonomously functioning volume of the thyroid

    International Nuclear Information System (INIS)

    Emrich, D.; Erlenmaier, U.; Pohl, M.; Luig, H.

    1993-01-01

    The aim of this work was to determine the autonomously functioning volume in euthyroid and hyperthyroid goitres for prognostic and therapeutic pruposes. To this end, various groups of patients were selected: Individuals without evidence of thyroid disease, euthyroid patients with diffuse goitre of normal structure and function, euthyroid patients with evidence of autonomy and patients with hyperthyroidism due to autonomy. In all of them the thyroid uptake of Technetium-99m was determined under exogeneous suppression (TcU s ) in the euthyroid state and under endogenous suppression (TcU) in the hyperthyroid state. It was demonstrated that: 1. In patients with unifocal autonomy the TcU s and TcU correlated linearly with the autonomous volume delineated and measured by sonography. 2. A nearly identical result was obtained if the mean autonomous volume in individuals without thyroid disease of 2.2±1.1 ml calculated by TcU s /TcU x total thyroid volume was used as a basis. 3. The critical autonomous volume, i.e. the volume at which hyperthryroidism will occur, was found to be 16 ml at a cumulated sensitivity and specificity of >0.9. The method can be used to select patients for definitive treatment before hyperthryroidism occurs and to measure the autonomously functioning volume independent of its distribution within the thyroid for treatment with radioiodine. The method is easy to perform and is also an example of how a relative parameter of a function can be converted into an absolute parameter of a functioning volume. (orig.)

  8. Thyroid gland volume of schoolchildren in the North of Iran: Comparison with other studies.

    Science.gov (United States)

    Kalantari, Saeed; Moghadam, Masrur Vahabi

    2015-11-01

    Few studies have shown the limitation of the World Health Organization (WHO)/ International Council for the Control of Iodine Deficiency (ICCIDD)-adopted thyroid gland volume references as universal normative values for thyroid gland volume. So we decided to measure thyroid gland volume by sonography in schoolchildren in Rasht, Gilan Province, Iran - Rasht is a metropolitan city on the Caspian Sea coast - and compare them to WHO normative values. In a cross-sectional study, 2,522 schoolchildren, aged 6-13 years, in Rasht, Gilan Province, Iran were selected by multistage random sampling. Data were collected on their age, sex, weight, height, body surface area (BSA), and thyroid gland size by palpation and sonography. The terminal phalange of thumb finger volume was calculated with the same formula used in sonography, for the thyroid gland in 1,085 of these cases. Goiter prevalence was 64% (1613 cases) by palpation, 76.1% (1228 subjects) grade I and 23.9% (385 cases) grade II. The mean thyroid gland volume in girls was more than boys (3.67 ± 1.89 mL vs 3.41 ± 1.58 mL, P thyroid gland volume reference, none of the children had goiter based on BSA and age even in those with grade II goiters (23.9%). In contrast, the median thyroid gland volume in our cases was larger than the 2004 WHO reference. The best single predictor of thyroid gland volume was age (R (2) = 0.391, P thyroid gland and finger volume in all grades of goiter and grade II goiters (3 ± 1.4 mL vs 9.59 ± 2.4 mL; P thyroid gland volume by sonography may underestimate or overestimate the goiter prevalence in many areas and populations. Finger volume was much larger than thyroid gland volume in even visible goiters.

  9. [The prognostic application of thyroid volume determination in patients with Graves' disease].

    Science.gov (United States)

    Sakane, S

    1990-05-20

    Swelling of the thyroid gland is a common symptom in patients with Graves' disease. However, until recently there were no adequate means of measuring the thyroid volume. In this study, thyroid volume (in Graves' disease patients on antithyroid drug (ATD) therapy) was measured serially by a new ultrasound technique involving the use of a specifically programmed computer. The relationships between thyroid volume and prognosis, and between thyroid volume and serum thyroglobulin (Tg) concentration were examined. Sixty untreated patients with Graves' disease and 62 healthy subjects were included in the study. Twenty of the 60 patients with Graves' disease who had no anti-Tg antibodies underwent serial measurement of thyroid volume and serum Tg concentration during long term (18-42 months) ATD therapy. Thyroid volume in normal subjects ranged from 5.6 ml to 20.2 ml, with a mean of 12.0 +/- 4.0 ml. In patients with untreated Graves' disease, the volume ranged from 13.3 to 190.7 ml with a mean of 40.2 +/- 27.8 ml (n = 60). Thyroid volume was significantly correlated with both serum Tg concentration (n = 20, r = 0.678, p less than 0.01) and serum TSH receptor antibody activity (n = 18, r = 0.590, p less than 0.01). During ATD therapy, the thyroid volume decreased gradually in most patients. Eleven of 20 treated patients experienced remission after therapy was discontinued, and in these patients, thyroid volume was significantly smaller (p less than 0.01) than before treatment. Four patients developed hypothyroidism due to over dosage of ATD at which time thyroid volume increased in all four. In the course of therapy, even during episodes of hypothyroidism changes in serum Tg concentrations paralleled changes in thyroid volume. After 12 months of therapy, thyroid volume expressed as a percentage of the pretreatment value was significantly smaller in patients in remission (77.6 +/- 8.9%) than in those who did not show remission (92.4 +/- 11.6%). These data suggest that serial

  10. Thyroid volume by ultrasound in asymptomatic gravid and non ...

    African Journals Online (AJOL)

    Background: The thyroid gland is among the most commonly imaged glands using ultrasound due to the limitation of clinical examination. During pregnancy, thyroid volume responds physiological to the increased demands for iodine and energy. An enlargement of the thyroid gland during gestation is, therefore, not ...

  11. Selenium status, thyroid volume, and multiple nodule formation in an area with mild iodine deficiency

    DEFF Research Database (Denmark)

    Rasmussen, Lone Banke; Schomburg, Lutz; Kohrle, Josef

    2011-01-01

    ) introduction of iodine fortification. Serum selenium concentration and urinary iodine were measured, and the thyroid gland was examined by ultrasonography in the same subjects. Associations between serum selenium concentration and thyroid parameters were examined in multiple linear regression models...... or logistic regression models.Results: Serum selenium concentration was found to be significantly, negatively associated with thyroid volume (P=0.006), and a low selenium status significantly increased the risk for thyroid enlargement (P=0.007). Furthermore, low serum selenium status had a tendency...... to increase the risk for development of multiple nodules (P=0.087).Conclusions: Low serum selenium concentration was associated with a larger thyroid volume and a higher prevalence of thyroid enlargement....

  12. Ultrasound assessment of thyroid gland volume in diabetic patients without overt thyroid disease

    Science.gov (United States)

    Nduka, Christopher C.; Adeyekun, Ademola A.

    2016-01-01

    Background: Diabetes mellitus and thyroid disease are known to mutually influence each other. Thyroid disease can worsen glycaemic control in diabetes, and patients with diabetes mellitus have increased incidence of thyroid disorders such as increase in size, compared to the normal population. Aims/Objectives: The aim of the study was to sonographically assess thyroid gland volume in Nigerian adult diabetic patients and compare with apparently healthy adults (controls). Subjects and Methods: The study setting was the Department of Radiology, University of Benin Teaching Hospital (UBTH) Nigeria. The thyroid gland in 120 diabetic subjects and equal number of apparently healthy controls was scanned with a 5-12 MHz linear transducer of a SONOACE X4 Machine. Thyroid gland volume was assessed. Statistical analysis was done with Statistical Package for the Social Sciences (SPSS) version 17 (SPSS Inc, Chicago, IL, USA). Results: Diabetics had significantly increased thyroid volume compared to age matched male and female control subjects (11.5 ± 5.2 cm3 vs 7.4 ± 1.9 cm3; P thyroid volume among diabetics. Conclusion: Diabetics have higher thyroid gland dimensions, compared to apparently healthy subjects. Gland proliferation from circulating insulin may play a role. This is not influenced by gender. PMID:27853029

  13. Ultrasound assessment of thyroid gland volume in diabetic patients without overt thyroid disease.

    Science.gov (United States)

    Nduka, Christopher C; Adeyekun, Ademola A

    2016-01-01

    Diabetes mellitus and thyroid disease are known to mutually influence each other. Thyroid disease can worsen glycaemic control in diabetes, and patients with diabetes mellitus have increased incidence of thyroid disorders such as increase in size, compared to the normal population. The aim of the study was to sonographically assess thyroid gland volume in Nigerian adult diabetic patients and compare with apparently healthy adults (controls). The study setting was the Department of Radiology, University of Benin Teaching Hospital (UBTH) Nigeria. The thyroid gland in 120 diabetic subjects and equal number of apparently healthy controls was scanned with a 5-12 MHz linear transducer of a SONOACE X4 Machine. Thyroid gland volume was assessed. Statistical analysis was done with Statistical Package for the Social Sciences (SPSS) version 17 (SPSS Inc, Chicago, IL, USA). Diabetics had significantly increased thyroid volume compared to age matched male and female control subjects (11.5 ± 5.2 cm3 vs 7.4 ± 1.9 cm3; Pthyroid volume among diabetics. Diabetics have higher thyroid gland dimensions, compared to apparently healthy subjects. Gland proliferation from circulating insulin may play a role. This is not influenced by gender.

  14. Association of thyroid gland volume, serum insulin-like growth factor-I, and anthropometric variables in euthyroid prepubertal children

    DEFF Research Database (Denmark)

    Boas, M.; Hegedus, L.; Feldt-Rasmussen, U.

    2009-01-01

    CONTEXT AND OBJECTIVE: Few studies have focused on the interrelation between thyroid size, anthropometric variables, and IGF-I in adults, but such data are lacking for children. We have investigated thyroid gland volume and several hormonal and anthropometric variables in prepubertal children....... DESIGN AND PARTICIPANTS: A total of 859 prepubertal euthyroid Danish children aged 4-9 yr underwent a thorough clinical investigation, including anthropometrical measurements and determination of TSH, thyroid hormones, autoantibodies, urinary iodine excretion, and thyroid volume (TV) by ultrasound....... Longitudinal growth data from birth were available. RESULTS: TV increased significantly with age (r = 0.487; P

  15. Measuring Quality in Thyroid Cancer Surgery

    Directory of Open Access Journals (Sweden)

    David F. Schneider

    2014-01-01

    Full Text Available Many of the surgical quality measures currently in use are not disease specific. For thyroid cancer, mortality and even recurrence are difficult to measure since mortality is rare and recurrence can take decades to occur. Therefore, there is a critical need for quality indicators in thyroid cancer surgery that are easily measured and disease specific. Here we will review recent research on two potential quality indicators in thyroid cancer surgery. The uptake percentage on postoperative radioactive iodine scans indicates the completeness of resection. Another measure, the lymph node ratio, is the proportion of metastatic nodes to the total number of nodes dissected. This serves as a more global measure of quality since it indicates not only the completeness of lymph node dissection but also the preoperative lymph node evaluation and decision-making. Together, these two quality measures offer a more accurate, disease-specific oncologic indicator of quality that can help guide quality assurance and improvement.

  16. Ultrasonographically measured change in thyroid status in lithium treated adult patients with mood disorder

    OpenAIRE

    Sekh Afrar Alam; Vinod Kumar Sinha; Haque Nizamie

    2016-01-01

    Background: Lithium, which is frequently used in the treatment of mood disorder, can lead to various types of thyroid dysfunctions. Although clinical examination and biochemical assessment are fundamental to any thyroid work-up of lithium-treated patients, assessment findings vary widely depending on the investigator. Ultrasonographic measurement of thyroid volume has, therefore, been performed in lithium treatment populations and found to be a sensitive tool. Aim: We aimed to determine and c...

  17. Thyroiditis

    Science.gov (United States)

    ... Anaplastic Thyroid Cancer Complementary and Alternative Medicine in Thyroid Disease FNA Biopsy of Thyroid Nodules Goiter Graves’ Disease ... Cancer Nuclear Radiation & the Thyroid Older Patients and Thyroid Disease Papillary & Follicular Thyroid Cancer Postpartum Thyroiditis Pregnancy and ...

  18. Iodine status and its correlations with age, blood pressure, and thyroid volume in South Indian women above 35 years of age (Amrita Thyroid Survey

    Directory of Open Access Journals (Sweden)

    Vadayath Usha Menon

    2011-01-01

    Full Text Available Background: Thyroid disorders are more commonly seen among females and the prevalence increases with age. There is no population data from India focusing on iodine levels and their correlations with thyroid volume and other factors in adult women. Aim: This study was designed to establish the iodine status and its relation with various factors including thyroid volume measured by ultrasound among the females of Kerala. Materials and Methods: This was a cross sectional house to house survey among the females above 35 years of age in a randomly selected urban area in Cochin Corporation, Kerala State, India. Selected subjects were interviewed, examined and blood and urine tests were done. Thyroid volume was calculated using ultrasound. Results: Among the 508 subjects who participated in the checkup, 471 subjects were included for analysis. Mean age was 50.3 + 10.7 years and 53.2% were postmenopausal. A total of 98% of the subjects were using iodized salt and median urinary iodine excretion (UIE was 162.6 mcg/l. UIE had negative correlation with age and systolic blood pressure (BP, but had no correlation with thyroid volume (TV, thyroid nodularity, free thyroxine 4 (FT4, thyroid stimulating hormone (TSH or anti thyroid peroxidase (TPO levels. Iodine deficiency was more commonly seen in subjects with hypertension and also among postmenopausal females. Conclusions: This study showed that females > 35 years were iodine sufficient, though one third of the subjects had UIE levels less than the recommended level. Iodine levels had significant negative correlation with age and systolic BP and no correlation with thyroid volume or biochemical parameters. Iodine deficiency was significantly higher in subjects with new and known hypertension and this relation merits further evaluation.

  19. Systematic determination of thyroid volume by ultrasound examination from infancy to adolescence in Japan: the Fukushima Health Management Survey.

    Science.gov (United States)

    Suzuki, Satoru; Midorikawa, Sanae; Fukushima, Toshihiko; Shimura, Hiroki; Ohira, Tetsuya; Ohtsuru, Akira; Abe, Masafumi; Shibata, Yoshisada; Yamashita, Shunichi; Suzuki, Shinichi

    2015-01-01

    Although several reports have defined normal thyroid volume depending on either age or body surface, there are no sequential reference values on childhood thyroid volume evaluated by using ultrasonography and epidemiological analysis in Japan. The aim of the present study was to establish updated reference values for thyroid volume by ultrasound examination and epidemiological analysis in 0-19 year-old Japanese children. It is based on a cross-sectional study conducted from October 9, 2011 to March 31, 2012. The subjects were 38,063 children who were examined by ultrasonography as the initial preliminary survey of the Fukushima Health Management Survey in October 9, 2011 to March 31, 2012. The width, thickness, and height of each lobe were measured and the volume of each lobe was calculated by the mean of the elliptical shape volume formula. The values of thyroid volume at the 2.5 and 97.5 percentiles of age and body surface area for each gender group were obtained from 0-19 year-old children. Positive correlation was observed between thyroid volume and either age or body surface. The right lobe was significantly larger than the left lobe. The thyroid volume in females was larger than that in males after adjusting body surface area. The reference values of childhood thyroid for each age or body surface area were obtained by this extensive survey using ultrasound. These reference values may be used to define the normal size of thyroid gland by echosonography in Japanese children, although thyroid volume may be affected by dimorphic factors such as sex hormones.

  20. Thyroid volume and urinary iodine in European schoolchildren: standardization of values for assessment of iodine deficiency

    NARCIS (Netherlands)

    Delange, F.; Benker, G.; Caron, P.; Eber, O.; Ott, W.; Peter, F.; Podoba, J.; Simescu, M.; Szybinsky, Z.; Vertongen, F.; Vitti, P.; Wiersinga, W.; Zamrazil, V.

    1997-01-01

    Up to 1992, most European countries used to be moderately to severely iodine deficient. The present study aimed at evaluating possible changes in the status of iodine nutrition in 12 European countries during the past few years. Thyroid volume was measured by ultrasonography in 7599 schoolchildren

  1. Prenatal sonographic measurement of the fetal thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Young Cheol; Kim, Young Hwa; Cho, Won Soo; Bae, Won Kyung; Kim, Il Young [Chunan Hospital, Soonchunhyang University College of Medicine, Chunan (Korea, Republic of)

    2001-03-15

    To investigate whether the fetal thyroid gland could be examined by prenatal ultrasonography and to established the normal range of fetal thyroid width according to the gestational age. The width of the fetal thyroid was determined by prenatal ultrasonography from 118 pregnant women. Three of the mothers had current or previous thyroid disease and the widths of the fetal thyroid were determined from 115 normal subjects. The width of the fetal thyroid was defined by a maximum transverse distance of the thyroid gland between two carotid arteries on transverse scan of the fetal neck. We analyzed the cause of non-measurable cases. The width of the fetal thyroid and Neo-TSH were compared in 19 subjects, including 3 subjects will current or previous thyroid disease. We could measure the fetal thyroid widths in 95 cases (80%). The fetal thyroid widths of mothers without current or previous thyroid disease was 0.9-2.36 cm,which showed linear correlation with gestational age (Y=0.0506 X + 0.0439, r{sup 2}=0.5661). Causes of non-measurable cases were neck flexion (65%), prone position (22%), and overlapped fetal neck by arm or shoulder (13%). Of the 19 neonates with Neo-TSH level, one case had a mother with a thyroid disease and showed increased width of the fetal and high Neo-TSH. The fetal thyroid was measured in 80% of prenatal ultrasonography and the width of the fetal thyroid showed linear correlated with gestational age. We assumed that the width of the thyroid could be useful for diagnosing fetal thyroid disorder when maternal thyroid disease exists.

  2. Prenatal sonographic measurement of the fetal thyroid gland

    International Nuclear Information System (INIS)

    Ahn, Young Cheol; Kim, Young Hwa; Cho, Won Soo; Bae, Won Kyung; Kim, Il Young

    2001-01-01

    To investigate whether the fetal thyroid gland could be examined by prenatal ultrasonography and to established the normal range of fetal thyroid width according to the gestational age. The width of the fetal thyroid was determined by prenatal ultrasonography from 118 pregnant women. Three of the mothers had current or previous thyroid disease and the widths of the fetal thyroid were determined from 115 normal subjects. The width of the fetal thyroid was defined by a maximum transverse distance of the thyroid gland between two carotid arteries on transverse scan of the fetal neck. We analyzed the cause of non-measurable cases. The width of the fetal thyroid and Neo-TSH were compared in 19 subjects, including 3 subjects will current or previous thyroid disease. We could measure the fetal thyroid widths in 95 cases (80%). The fetal thyroid widths of mothers without current or previous thyroid disease was 0.9-2.36 cm,which showed linear correlation with gestational age (Y=0.0506 X + 0.0439, r 2 =0.5661). Causes of non-measurable cases were neck flexion (65%), prone position (22%), and overlapped fetal neck by arm or shoulder (13%). Of the 19 neonates with Neo-TSH level, one case had a mother with a thyroid disease and showed increased width of the fetal and high Neo-TSH. The fetal thyroid was measured in 80% of prenatal ultrasonography and the width of the fetal thyroid showed linear correlated with gestational age. We assumed that the width of the thyroid could be useful for diagnosing fetal thyroid disorder when maternal thyroid disease exists.

  3. Substantial interobserver variation of thyroid volume and function by visual evaluation of thyroid (99m)Tc scintigraphy

    DEFF Research Database (Denmark)

    Soelberg, Kerstin; Grupe, Peter; Boel-Jørgensen, Henrik

    2014-01-01

    (99m)Tc-pertechnetate scintigraphy is much used in the evaluation of patients with nodular goitre. We investigated the ability of experienced observers to estimate the thyroid 24-h (131)I uptake (RAIU) and the thyroid volume by visual evaluation of the scintigram.......(99m)Tc-pertechnetate scintigraphy is much used in the evaluation of patients with nodular goitre. We investigated the ability of experienced observers to estimate the thyroid 24-h (131)I uptake (RAIU) and the thyroid volume by visual evaluation of the scintigram....

  4. Interrelationships between age, thyroid volume, thyroid nodularity, and thyroid function in patients with sporadic nontoxic goiter

    NARCIS (Netherlands)

    Berghout, A.; Wiersinga, W. M.; Smits, N. J.; Touber, J. L.

    1990-01-01

    To test the hypothesis that during the natural history of sporadic nontoxic goiter (SNG), a diffuse goiter precedes a multinodular goiter with gradual development of autonomous thyroid function. A cross-sectional survey of 102 consecutive patients with SNG (seven male, 95 female) was performed.

  5. Thyroid disease

    International Nuclear Information System (INIS)

    Falk, S.

    1990-01-01

    Presenting a multidisciplinary approach to the diagnosis and treatment of thyroid disease, this volume provides a comprehensive picture of current thyroid medicine and surgery. The book integrates the perspectives of the many disciplines that deal with the clinical manifestations of thyroid disorders. Adding to the clinical usefulness of the book is the state-of-the-art coverage of many recent developments in thyroidology, including the use of highly sensitive two-site TSH immunoradionetric measurements to diagnose thyroid activity; thyroglobulin assays in thyroid cancer and other diseases; new diagnostic applications of MRI and CT; treatment with radionuclides and chemotherapy; new developments in thyroid immunology, pathology, and management of hyperthyroidism; suppressive treatment with thyroid hormone; and management of Graves' ophthalmopathy. The book also covers all aspects of thyroid surgery, including surgical treatment of hyperthyroidism; papillary, follicular, and other carcinomas; thyroidectomy; and prevention and management of complications

  6. Effects of 1-year growth hormone replacement therapy on thyroid volume and function of the children and adolescents with idiopathic growth hormone deficiency.

    Science.gov (United States)

    Keskin, Meliksah; Bayramoglu, Elvan; Aycan, Zehra

    2017-10-26

    There are different opinions about the effects of growth hormone replacement therapy (GHRT) on thyroid function and volume. This study aimed to assess the effects of GHRT on thyroid volume and function in the children and adolescents with growth hormone (GH) deficiency. A total of 29 patients diagnosed with GH deficiency were enrolled in the study. The control group consisted of 29 cases matched for age, gender and pubertal period with the patients. Thyroid function tests and insulin-like growth factor levels were measured, simultaneously thyroid volumes were assessed by ultrasonography at the initiation period and at the end of GHRT. Thyroid volumes of the patient group was -0.55±1.1 standard deviations (SDs) initially; whereas at the end of 1 year it was found to be -0.29±1.29 SDs and both SDs of thyroid volumes did not differ significantly. The SDs of thyroid volume of the control group was -0.85±1.03 SDs initially and -0.72±0.85 SDs at the end of 1 year; and they did not differ significantly. On the other hand, after GHRT of 1 year, thyroid stimulating hormone (TSH) and free thyroxine (T4) levels decreased. It was observed that SDs of thyroid gland volumes did not change in GH deficient children and adolescents after GHRT.

  7. Comparative ultrasound measurement of normal thyroid gland ...

    African Journals Online (AJOL)

    2011-08-31

    Aug 31, 2011 ... the normal thyroid gland has a homogenous increased medium level echo texture. The childhood thyroid gland dimension correlates linearly with age and body surface unlike adults. [14] Iodothyronine (T3) and thyroxine (T4) are thyroid hormones which function to control the basal metabolic rate (BMR).

  8. Comparative ultrasound measurement of normal thyroid gland dimensions in school aged children in our local environment.

    Science.gov (United States)

    Marchie, T T; Oyobere, O; Eze, K C

    2012-01-01

    The objective of this study was to determine the measurement of normal range of ultrasound (US) thyroid gland dimensions in school-aged children (6-16 years) in our environment and compared with what is obtained elsewhere. A prospective ultrasound measurement study done in University of Benin Teaching Hospital Benin, Nigeria. A prospective ultrasound (US) study of thyroid dimensions of 500 school-aged children in our environment consisting of 227 boys and 273 girls was done from 1 December 2006 to July 2007. The subjects were examined by the authors and subjects with palpable abnormal thyroid gland were excluded from the study. The thyroid dimensions (length, height, and diameter) were taken for each lobe by means of ultrasound (US). In addition volume of each thyroid lobe was calculated and the summation of volume of the lobes was taken as thyroid gland volume of each subject. Also height and weight of patients were documented from which the subject's body surface was calculated. Incidental thyroid gland lesion in US was excluded from the study. Using the Statistical program of social science (SPSS) and INSTAT (Graph Pad Inc. USA) the data were analyzed. Informed consent was obtained from all the subjects and the study was done in line with the ethical guidelines of the centers. The US thyroid gland volume in school-aged children in Benin City from this study ranges between 1.17 cm 3 and 7.19 cm 3 , mean volume range of 1.76-4.95 cm 3 , median volume range of 1.73-4.73 cm 3 , and range of standard deviation from 0.39 cm 3 to 1.49 cm 3 . The average mean thyroid volume is 2.32 cm 3 with the following average dimensions; anteroposterior right lobe =1.06 cm, mediolateral right lobe = 1.01 cm and craniocaudal right lobe = 2.34 cm, and anteroposterior left lobe = 1.01 cm, mediolateral left lobe = 1.04 cm and craniocaudal left lobe = 2.41 cm for both boys and girls respectively. These data are significantly lower than data obtained by European based World Health

  9. The determination of the volume of the thyroid gland by a new ultrasonic scanner

    International Nuclear Information System (INIS)

    Yokoyama, Naokata; Izumi, Motomori; Nagataki, Shigenobu; Hazama, Ryuji; Kurata, Akihiko; Ishikawa, Naofumi; Ito, Kunihiko.

    1984-01-01

    A newly developed high-resolution ultrasonic scanner for determining the volume of the thyroid gland was employed in 1983's health screening for A-bomb survivors in Nishiyama district (Nagasaki), and effects of radiation on the thyroid gland were examined. Thirty-one inhabitants who have been living in Nishiyama district since the A-bombing were selected as subjects (Nishiyama group) and their sex- and age-matched persons were selected as controls (control group). Regarding the incidence of chronic thyroiditis, Graves' disease, thyroid adenoma, and hypothyroidism, there was no significant difference between the groups. The volume of the thyroid gland was 14.6+-6.2 ml in the Nishiyama group and 13.1+-4.0 ml in the control group; the average volume of the thyroid gland was a little higher in the Nishiyama group than in the control group, but this was not statistically significant. (Namekawa, K.)

  10. Influence of Bisphenol A on Thyroid Volume and Structure Independent of Iodine in School Children.

    Directory of Open Access Journals (Sweden)

    Na Wang

    Full Text Available Although several studies have evaluated the relationship between bisphenol A (BPA and thyroid functions, their results are not entirely consistent. Little is known about BPA in relation to thyroid volume and structure.We examined the association of BPA with thyroid volume and thyroid nodules using data from 718 Chinese children living in the East Coast of China in 2012. First morning urine samples were collected for the determination of urinary BPA, creatinine, and urinary iodine concentrations (UIC. Thyroid volume (TV and nodules were assessed by thyroid ultrasonography.The median of TV was 3.14ml. 459(63.9% children took iodized salt at home and the median of UIC was 159μg/l. BPA was detected in 99.9% of the urine samples and the medians for boys and girls were 2.64 and 2.35μg/g creatinine, respectively. Of all participants 14.0% had thyroid nodules. Urinary BPA concentration was inversely associated with thyroid volume (β = -0.033, 95% CI: -0.053, -0.013 and the risk for multiple nodules (OR = 0.78; 95% CI: 0.63, 0.97. The associations above were similar for children who consumed iodized salt and those consumed non-iodized salt.The data suggest that BPA may be one of the influencing factors for TV and thyroid nodules and its effects are independent of iodine nutrition status in children.

  11. Size measurement of the thyroid gland on a magnified pinhole thyroid scan using an ultrasonic device measuring distance from the pinhole to the thyroid gland.

    Science.gov (United States)

    Ahn, Byeong-Cheol; Ahn, Gilhwan; Kim, Do-Hoon; Kim, Kyoung Dong; Jeong, Shin Young; Lee, Sang-Woo; Lee, Jaetae

    2015-02-01

    Pinhole has been used for magnification of gamma camera images and is valuable for imaging of small organs, such as thyroid; however, size of the organ cannot be measured on the image due to variable degree of magnification by distance between the pinhole and the organ. The aim of this study was to develop a true size measuring system (TSM system) on magnified pinhole thyroid scan using an ultrasonic sensor. An ultrasonic device capable of measuring the distance from the pinhole to the skin overlying the thyroid gland was manufactured using a ~40 kHz piezoelectric-transducer-based sensor, and its accuracy was tested. An interface program was developed and fused with the ultrasonic device for development of the TSM system. Accuracy of the TSM system for measuring size was tested with phantom images and 35 thyroid scans. The ultrasonic device accurately measured the distance from the pinhole to the skin over the thyroid gland and the measured values were highly reproducible (6 cm; 6.02 ± 0.04 cm, 8 cm; 8.00 ± 0.05 cm, 10 cm; 10.00 ± 0.05 cm). Distance on the phantom image corrected by the TSM system was almost the same as the true distance. Size of the thyroid on the pinhole image was larger (+67.3 to 103.1 %) than the true thyroid size on the parallel-hole image and the magnification decreased by increase of the distance between the pinhole and the skin over the thyroid gland. However, size of the thyroid obtained using the TSM system was almost equal (-2.1 to +3.6 %) to the true thyroid size on the parallel-hole image. We developed the TSM system for magnified pinhole images using a distance measuring ultrasonic sensor. Size of the thyroid on the magnified pinhole image obtained using the system was almost the same as the true thyroid size. The TSM system can be applied to obtain accurate size of the thyroid gland or lesions in the thyroid gland on pinhole thyroid scan.

  12. Comparative methods for quantifying thyroid volume using planar imaging and SPECT

    International Nuclear Information System (INIS)

    Zaidi, H.

    1996-01-01

    Thyroid volume determination using planar imaging is a procedure often performed in routine nuclear medicine, but is hampered by several physical difficulties, in particular by structures which overlie or underlie the organ of interest. SPECT enables improved accuracy over planar imaging in the determination of the volume since it is derived from the 3-D data rather than from a 2-D projection with a certain geometric assumption regarding the thyroid configuration. By using the phantoms of known volume, it was possible to estimate the accuracy of 3 different methods of determining thyroid volume from planar imaging used in clinical routine. The experimental results demonstrate that compared with conventional scintigraphy, thyroid phantom volumes were most accurately determined with SPECT when attenuation and scatter corrections are performed which allows accurate radiation dosimetry in humans without the need for assumptions on organ size or concentrations. Poster 181. (author)

  13. Local Reference Ranges of Thyroid Volume in Sudanese Normal Subjects Using Ultrasound

    Directory of Open Access Journals (Sweden)

    Mohamed Yousef

    2011-01-01

    Full Text Available This study aimed to establish a local reference of thyroid volume in Sudanese normal subjects using ultrasound. A total of 103 healthy subjects were studied, 28 (27.18% females and 75 (72.82% males. Thyroid volume was estimated using ellipsoid formula. The mean age and range of the subjects was 21.8 (19–29 years; the mean body mass index (BMI was 22.3 (16.46–26.07 kg/m2. The overall mean volume ± SD volume of the thyroid gland for both lobes in all the patients studied was 6.44 ± 2.44 mL. The mean volume for both lobes in females and males were 5.78 ± 1.96 mL and 6.69 ± 2.56 mL, respectively. The males' thyroid volume was greater than the females'. The mean volume of the right and left lobes of the thyroid gland in males and females were 3.38 ± 1.37 mL and 3.09 ± 1.24 mL, respectively. The right thyroid lobe volume was greater than the left. The values obtained in this study were lower than those reported from previous studies.

  14. Measurement of radioiodine content in thyroid of occupationally exposed personnel

    International Nuclear Information System (INIS)

    Krajewska, G.; Krajewski, P.

    2005-01-01

    Full text: The I-131 content in the thyroid of staff members working with radioiodine has been measured in some Departments of Nuclear Medicine performing therapy and diagnosis of thyroid disease in Poland. The measurements were performed with mobile detection unit for 'in situ' measurements of I-131 and I-125 (Canberra-Packard prod.) in selected as low as possible background places. The measured personnel can be divided into some categories according to internal contamination risk to unsealed sources of I-131: technical staff mainly performing routine diagnostic investigation; nuclear medicine staff (physician, nurse) working with in vivo administration of I-131 to patients; hospital services staff (orderlies, cleaners) performing auxiliary activities to the patients. All individuals actively working with iodine show measurable amounts of the radioiodine in their thyroids. The average measured activity in the thyroid of the nuclear medicine staff was found to be equal at average 400 Bq within the range from 30 Bq to 3500 Bq. There is no apparent correlation between the measured I-131 levels and risk categories. The average and range of I-131 activity measured in thyroids for all medical units were: 590 Bq, (30 Bq - 3000 Bq), 300 Bq, (30 Bq - 3000 Bq), 140 Bq, (30 Bq - 700 Bq) for categories 1, 2 and 3 respectively. Nevertheless the 1 and 2 categories show higher I-131 thyroid level comparing to category 3. Based on results of measurements, the Effective Dose Equivalent for particular person due to inhalation of I-131 was calculated with somewhat a conservative assumption that I-131 thyroid content remains constant during the whole year. For the occupational exposure limit of 20 mSv it gives the reference I-131 thyroid level is equal to 7 kBq. Calculated average Effective Dose Equivalent for particular medical is below 25 per cent of 20 mSv/year. (author)

  15. Thyroid hormone effect on human mitochondria measured by flow cytometry

    DEFF Research Database (Denmark)

    Kvetny, Jan; Bomholt, Tobias; Pedersen, Palle

    2009-01-01

    a method to measure mitochondrial function in human derived cells, which also would reflect regulation by thyroid hormones. METHODS: The MDA-MB-231 cell line (a human breast cancer cell line) was incubated with bioactive iodothyronines (T(4), 3'-3, 5-T(3), 3, 5-T(2)) 50 nmol/l for 3 h. Mitochondrial...... membrane potentials (MMP) were measured by a flow cytometer after staining with Tetramethylrhodamine methyl ester (TMRM). Also, the effect of TRIAC (a stimulator of thyroid hormone nuclear receptors) and L-Carnitine (an inhibitor of thyroid hormone passage into the nucleus) was examined. FINDINGS......: It was possible to measure mitochondrial membrane potential (MMP) in human derived cells and to examine thyroid hormone effects using flow cytometry. Bioactive iodothyronines increased mitochondrial membrane potential. TRIAC had no effect and L-Carnitine only inhibited T(4) stimulation of membrane potential...

  16. Evaluation of the Efficacy of Standardized Uptake Value (SUV-shape Scheme for Thyroid Volume Determination in Graves’ Disease: A Comparison with Ultrasonography

    Directory of Open Access Journals (Sweden)

    yangchun chen

    2017-01-01

    Full Text Available Objective(s: In this study, we aimed to evaluate the efficacy of thyroid volume measurement using 99mTc pertechnetate single-photon emission computed tomography (SPECT images, acquired by the standardized uptake value (SUV-shape scheme designed by our expert team.Methods: A total of 18 consecutive patients with Graves’ disease (GD were subjected to both ultrasonographic and 99mTc pertechnetate SPECT examinations of thyroid within a five-day interval. The volume of thyroid lobes and isthmus was measured by ultrasonography (US according to the ellipsoid volume equation. The total thyroid volume, determined as the sum of the volume of both lobes and isthmus, was recorded as TV-US (i.e., thyroid volume measured by US and set as the reference. The thyroid volume was defined according to our SUV-shape scheme and was recorded as TV-SS (i.e., thyroid volume determined by the SUV-shape scheme. The data were analyzed using the Bland-Altman plot, linear regression analysis, Spearman’s rank correlation, and paired t-test, if necessary.Results: The values of TV-SS (40.2±29.4 mL and TV-US (43.0±34.7 mL were not significantly different (t=0.813; P=0.43. The linear regression equation of the two values was determined as TV-US= 1.072 × TV-SS − 0.29(r=0.906; P

  17. Thyroid monitoring system for measurement of iodine content in thyroid of occupationally exposed personnel

    International Nuclear Information System (INIS)

    Krajewska, G.; Krajewski, P.

    2000-01-01

    Two monitoring systems for measurements of 131 I and 125 I content in the thyroid are presented: the Stationary Unit for measuring 131 I and 125 I with a low limit of detection and the Mobile Unit for in situ measurements of 131 I and 125 I. The study of counting geometry optimisation showed that the mobile unit's unshielded detector required a shorter thyroid-detector distance of about 15 cm. This ensured a lower limit of detection at the possible local background fluctuation. The results of measurements of 131 I content in the thyroids of staff members working with radioiodine in four Departments of Nuclear Medicine do not show any correlation between the measured 131 I levels and risk categories. Instead, there are significant differences in the averages of measured 131 I thyroid contents for the particular medical unit. These differences do not necessarily depend on 131 I usage in the particular medical unit but rather depend on specific and complex work conditions, staff training and so on. Average Effective Dose Equivalent values for all medical units are below 10% of the occupational exposure limit of 50 mSv.y -1 . (author)

  18. Effect of Thyroid Remnant Volume on the Risk of Hypothyroidism After Hemithyroidectomy: A Prospective Study.

    Science.gov (United States)

    Lang, Brian Hung-Hin; Wong, Carlos K H; Wong, Kai Pun; Chu, Kelvin Ka-Wan; Shek, Tony W H

    2017-06-01

    Hypothyroidism is a common sequel after a hemithyroidectomy. Although various risk factors leading to hypothyroidism have been reported, the effect of the contralateral lobe's volume has been understudied. This study aimed to examine the association between the preoperative contralateral lobe's volume and the risk of postoperative hypothyroidism. During a 2-year period, 150 eligible patients undergoing a hemithyroidectomy were evaluated. The volume of the contralateral nonexcised lobe was estimated preoperatively by independent assessors on ultrasonography using the following formula: width (in cm) × depth (in cm) × length (in cm) × (π/6), adjusted for the body surface area (BSA). Postoperative hypothyroidism was defined as serum thyroid-stimulating hormone (TSH) exceeding 4.78 mIU/L. Any significant characteristics in the univariate analysis were entered into the multivariate analysis to determine independent factors. After a mean follow-up period of 53.5 ± 9.4 months, 44 patients (29.3 %) experienced postoperative hypothyroidism, and 10 of these patients required thyroxine replacement. Hypothyroidism was associated with a higher preoperative TSH level (p hypothyroidism. Patients with a BSA-adjusted volume smaller than 3.2 ml had a threefold greater hypothyroidism risk than those with a BSA-adjusted volume of 3.2 ml or more (p hypothyroidism risk was observed after hemithyroidectomy. Together with a higher preoperative TSH level and fewer ipsilateral nodules, a smaller BSA-adjusted volume measured by preoperative ultrasonography independently predicted hypothyroidism.

  19. A mathematical formula to estimate in vivo thyroid volume from two-dimensional ultrasonography.

    Science.gov (United States)

    Trimboli, Pierpaolo; Ruggieri, Massimo; Fumarola, Angela; D'Alò, Michele; Straniero, Andrea; Maiuolo, Amelia; Ulisse, Salvatore; D'Armiento, Massimino

    2008-08-01

    The determination of thyroid volume (TV) is required for the management of thyroid diseases. Since two-dimensional ultrasonography (2D-US) has become the accepted method for the assessment of TV (2D-US-TV), we verified whether it accurately assesses postsurgical measured TV (PS-TV). In 92 patients who underwent total thyroidectomy by conventional cervicotomy, 2D-US-TV obtained by the ellipsoid volume formula was compared to PS-TV, determined by the Archimedes' principle. Mean 2D-US-TV (23.9 +/- 14.8 mL) was significantly lower than mean PS-TV (33.4 +/- 20.1 mL). Underestimation was observed in 77% of cases, and it was related to gland multinodularity and/or nodular involvement of the isthmus, while 2D-US-TV matched the PS-TV in the remaining 21 cases (23%). A mathematical formula, to estimate PS-TV from US-TV, was derived using a linear model (Calculated-TV = [1.24 x 2D-US-TV]+ 3.66). Calculated-TV (mean value 33.4 +/- 18.3 mL) significantly (p < 0.01) increased from 21 (23%) to 31 (34%) of the cases that matched PS-TV. In addition, it significantly (p < 0.01) decreased from 77% to 27% the percentage of cases where PS-TV was underestimated as well as the range of the disagreement from 245% to 92%. This study shows that 2D-US does not provide an accurate estimation of TV and suggests that it can be improved by a mathematical model different from the ellipsoid model. If confirmed in prospective studies, this may contribute to a more appropriate management of thyroid diseases.

  20. Shrinkage of thyroid volume in sunitinib-treated patients with renal-cell carcinoma: a potential marker of irreversible thyroid dysfunction?

    Science.gov (United States)

    Rogiers, Aljosja; Wolter, Pascal; Op de Beeck, Katya; Thijs, Marleen; Decallonne, Brigitte; Schöffski, Patrick

    2010-03-01

    The multitargeted tyrosine kinase inhibitor sunitinib is known to induce thyroid dysfunction in a substantial proportion of patients treated for advanced renal-cell carcinoma or gastrointestinal stromal tumors. Although sunitinib-induced hypothyroidism seems to be reversible in the majority of patients, some patients develop irreversible thyroid damage resulting in long-lasting thyroid hormone replacement therapy. We report on two cancer patients with a preexisting nodular thyroid gland, who developed thyroid dysfunction and showed marked shrinkage of the thyroid during treatment with the tyrosine kinase inhibitor, necessitating permanent thyroid hormone replacement therapy even after discontinuation of the anticancer agent. Sunitinib treatment in patients with a nodular thyroid can induce a significant decrease in the volume of the enlarged endocrine gland, associated with abnormal thyroid function tests leading to clinical hypothyroidism. The exact pathophysiology remains unknown but we discuss several possible mechanisms of sunitinib-induced thyroid shrinkage. Morphological changes of the thyroid gland can be associated with the well-described adverse biochemical effects of treatment with sunitinib and can be a potential marker of the irreversible organ damage.

  1. Development and test of sets of 3D printed age-specific thyroid phantoms for 131I measurements

    Science.gov (United States)

    Beaumont, Tiffany; Caldeira Ideias, Pedro; Rimlinger, Maeva; Broggio, David; Franck, Didier

    2017-06-01

    In the case of a nuclear reactor accident the release contains a high proportion of iodine-131 that can be inhaled or ingested by members of the public. Iodine-131 is naturally retained in the thyroid and increases the thyroid cancer risk. Since the radiation induced thyroid cancer risk is greater for children than for adults, the thyroid dose to children should be assessed as accurately as possible. For that purpose direct measurements should be carried out with age-specific calibration factors but, currently, there is no age-specific thyroid phantoms allowing a robust measurement protocol. A set of age-specific thyroid phantoms for 5, 10, 15 year old children and for the adult has been designed and 3D printed. A realistic thyroid shape has been selected and material properties taken into account to simulate the attenuation of biological tissues. The thyroid volumes follow ICRP recommendations and the phantoms also include the trachea and a spine model. Several versions, with or without spine, with our without trachea, with or without age-specific neck have been manufactured, in order to study the influence of these elements on calibration factors. The calibration factor obtained with the adult phantom and a reference phantom are in reasonable agreement. In vivo calibration experiments with germanium detectors have shown that the difference in counting efficiency, the inverse of the calibration factor, between the 5 year and adult phantoms is 25% for measurement at contact. It is also experimentally evidenced that the inverse of the calibration factor varies linearly with the thyroid volume. The influence of scattering elements like the neck or spine is not evidenced by experimental measurements.

  2. Pitfalls in the measurement and interpretation of thyroid function tests.

    Science.gov (United States)

    Koulouri, Olympia; Moran, Carla; Halsall, David; Chatterjee, Krishna; Gurnell, Mark

    2013-12-01

    Thyroid function tests (TFTs) are amongst the most commonly requested laboratory investigations in both primary and secondary care. Fortunately, most TFTs are straightforward to interpret and confirm the clinical impression of euthyroidism, hypothyroidism or hyperthyroidism. However, in an important subgroup of patients the results of TFTs can seem confusing, either by virtue of being discordant with the clinical picture or because they appear incongruent with each other [e.g. raised thyroid hormones (TH), but with non-suppressed thyrotropin (TSH); raised TSH, but with normal TH]. In such cases, it is important first to revisit the clinical context, and to consider potential confounding factors, including alterations in normal physiology (e.g. pregnancy), intercurrent (non-thyroidal) illness, and medication usage (e.g. thyroxine, amiodarone, heparin). Once these have been excluded, laboratory artefacts in commonly used TSH or TH immunoassays should be screened for, thus avoiding unnecessary further investigation and/or treatment in cases where there is assay interference. In the remainder, consideration should be given to screening for rare genetic and acquired disorders of the hypothalamic-pituitary-thyroid (HPT) axis [e.g. resistance to thyroid hormone (RTH), thyrotropinoma (TSHoma)]. Here, we discuss the main pitfalls in the measurement and interpretation of TFTs, and propose a structured algorithm for the investigation and management of patients with anomalous/discordant TFTs. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Does ultrasonographic volume of the thyroid gland correlate with difficult intubation? An observational study

    Directory of Open Access Journals (Sweden)

    Basak Ceyda Meco

    Full Text Available BACKGROUND AND OBJECTIVES: Preoperative ultrasonographic evaluation of the thyroid gland done by surgeons could let us foresee airway management challenges. The aim of this observational study was to evaluate the effects of thyroid-related parameters assessed preoperatively by surgeons via ultrasonography and chest X-ray on intubation conditions. METHODS: Fifty patients undergoing thyroid surgery were enrolled. Thyromental distance, Mallampati score, neck circumference and range of neck movement were evaluated before the operation. Thyroid volume, signs of invasion or compression and tracheal deviation on chest X-ray were also noted. The intubation conditions were assessed with Cormack and Lehane score and the intubation difficulty scale. Statistical analyses were done with SPSS 15.0 software. RESULTS: The mean thyroid volume of the patients was 26.38 ± 14 mL. The median intubation difficulty scale was 1 (0-2. Thyromental distance (p = 0.011; r = 0.36; 95% CI 0.582-0.088, Mallampati score (p = 0.041; r = 0.29; 95% CI 0.013-0.526, compression or invasion signs (p = 0.041; r = 0.28; 95% CI 0.006-0.521 and tracheal deviation on chest X-ray (p = 0.041; r = 0.52; 95% CI 0.268-0.702 were correlated with intubation difficulty scale. Also patients were classified into two groups related to their intubation difficulty scale (Group I, n = 19: intubation difficulty scale = 0; Group II, n = 31: 1 < intubation difficulty scale ≤ 5 and difficult intubation predictors and thyroid-related parameters were compared. Only Mallampati score was significantly different between groups (p = 0.025. CONCLUSION: The thyroid volume is not associated with difficult intubation. However clinical assessment parameters may predict difficult intubation.

  4. Thyroid doses in Belarus resulting from the Chernobyl accident: comparison of the estimates based on direct thyroid measurements and on measurements of 131I in milk

    International Nuclear Information System (INIS)

    Shinkarev, Sergey; Gavrilin, Yury; Khrouch, Valery; Savkin, Mikhail; Bouville, Andre; Luckyanov, Nicholas

    2008-01-01

    A substantial increase of childhood cancer cases observed in Belarus, Ukraine and Russia after the Chernobyl accident has been associated with thyroid exposure to radio iodines following the accident. A large number of direct thyroid measurements (i.e. measurement of the exposure rate near the thyroid of the subject)were conducted in Belarus during a few weeks after the accident. Individual thyroid doses based on results of the direct thyroid measurements were estimated for about 126,000 Belarusian residents and settlement-average thyroid doses for adults were calculated for 426 contaminated settlements in Gomel and Mogilev Oblasts. Another set of settlement-average thyroid doses for adults was estimated based on results of activity measurements in milk samples for 28 settlements (with not less than 2 spectrometric measurements) and 155 settlements (with not less than 5 total beta-activity measurements) in Gomel and Mogilev Oblasts. Concentrations of 131 I in milk were derived from these measurements. In the estimation of this set of thyroid doses, it was assumed that adults consumed 0.5 L d -1 of milk locally produced. The two sets of dose estimates were compared for 47 settlements, for which simultaneously were available a dose estimate based on thyroid measurements and a dose estimate based either on spectrometric or radiometric milk data. The settlement average thyroid doses based on milk activity measurements were higher than those based on direct thyroid measurements by a factor of 1.8 for total beta-activity measurements (30 settlements were compared) and by a factor of 2.4 for spectrometric measurements (17 settlements). This systematic difference can be explained by overestimation of the milk consumption rate used in the calculation of the milk-based thyroid doses and/or by application of individual countermeasures by people. (author)

  5. Preliminary fundamental aspects on the thyroid volume and function in the population of long term heavily polluted area in East Slovakia

    Energy Technology Data Exchange (ETDEWEB)

    Langer, P. [Institute of Experimental Endocrinology, SAS, Bratislava (Slovakia); Tajtakova, M. [Safarik Univ., Kosice (Slovakia). First Clinic of Internal Medicine; Kocan, A. [Slovak Health Univ. - IPCM, Bratislava (SK). Research Base] (and others)

    2004-09-15

    Our previous examinations of employees of chemical factory formerly producing polychlorinated biphenyls (PCB) repeatedly showed increased thyroid volume as measured by ultrasound as well as increased frequency of thyroperoxidase, thyroglobulin and thyrotropin (TSH) receptor autoantibodies. At the same time a considerable PCB pollution of soil, waters and food chain in large area surrounding that chemical factory was found. The aim of present preliminary evaluation of data obtained within the EC project PCBRISK was to search for further interrelations between long-term organochlorine pollution and fundamental markers of thyroid volume and function in large cohorts of population from three districts of East Slovakia.

  6. Measuring the actual I-131 thyroid uptake curve with a collar detector system: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Brinks, Peter; Van Gils, Koen; Dickerscheid, Dennis B.M.; Habraken, Jan B.A. [Department of Medical Physics, St. Antonius Hospital, Nieuwegein (Netherlands); Kranenborg, Ellen; Lavalaye, Jules [Department of Nuclear Medicine, St. Antonius Hospital, Nieuwegein (Netherlands)

    2017-06-15

    Radionuclide therapy using I-131 is commonly used for the treatment of benign thyroid diseases. The therapeutic dose to be administered is calculated based on the type of disease, the volume of the thyroid, and the measured uptake percentage. This methodology assumes a similar biological half-life of iodine, whereas in reality a large variation in biological half-life is observed. More knowledge about the actual biological half-life of iodine for individual patients will improve the quantification of the delivered radiation dose during radioiodine therapy and could aid the evaluation of the success of the therapy. In this feasibility study we used a novel measurement device [Collar Therapy Indicator (CoTI)] to measure the uptake curve of patients undergoing I-131 radioiodine therapy. The CoTI device is a light-weight wearable device that contains two independent gamma radiation detectors that are placed in a collar. By comparing results of thyroid uptake measurements with results obtained with a gamma camera, the precision of the system is demonstrated. Additionally, for three patients the uptake curve is measured during 48 h of admission in the hospital. The presented results demonstrate the feasibility of the new measurement device to measure the uptake curve during radioiodine therapy. (orig.)

  7. Effect of occupational exposure to cobalt blue dyes on the thyroid volume and function of female plate painters

    DEFF Research Database (Denmark)

    Prescott, E; Netterstrøm, B; Faber, J

    1992-01-01

    It has previously been shown that long-term oral exposure to cobalt can cause goiter and myxedema. The effect of industrial cobalt exposure on thyroid volume and function was determined for 61 female plate painters exposed to cobalt blue dyes in two Danish porcelain factories and 48 unexposed...... referents. Thyroid volume was determined by ultrasonography. The cobalt blue dyes were used in one of two forms, cobalt aluminate (insoluble) and cobalt-zinc silicate (semisoluble). Only the subjects exposed to semisoluble cobalt had a significantly increased urinary cobalt content (1.17 micrograms.mmol-1...... volume tended to be lower (P = 0.14). The group exposed to insoluble cobalt did not differ significantly in any thyroid-related parameters. No correlation between urinary cobalt and FT4I or thyroid volume was found. The study demonstrates an effect of cobalt on thyroid hormone metabolism....

  8. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  9. Levels of thyroxine, TSH, thyroid volume and mental performance among Orang Asli in selected settlements in Malaysia.

    Science.gov (United States)

    Osman, A; Zaleha, M I; Iskandar, Z A; Tan, T T; Ali, M M; Roslan, I; Khalid, B A

    1996-04-01

    A significant difference in the levels of thyroxine (T4), thyroid stimulating hormone (TSH) and thyroid volume among settlements at various selected Orang Asli locations is reported. The levels improved according to the level of socio-economic development. No significant difference was found in mental performance by location.

  10. The estimation of the thyroid volume before surgery--an important prerequisite for minimally invasive thyroidectomy.

    Science.gov (United States)

    Ruggieri, M; Fumarola, A; Straniero, A; Maiuolo, A; Coletta, I; Veltri, A; Di Fiore, A; Trimboli, P; Gargiulo, P; Genderini, M; D'Armiento, M

    2008-09-01

    Actually, thyroid volume >25 ml, obtained by preoperative ultrasound evaluation, is a very important exclusion criteria for minimally invasive thyroidectomy. So far, among different imaging techniques, two-dimensional ultrasonography has become the more accepted method for the assessment of thyroid volume (US-TV). The aims of this study were: (1) to estimate the preoperative thyroid volume in patients undergoing minimally invasive total thyroidectomy using a mathematical formula and (2) to verify its validity by comparing it with the postsurgical TV (PS-TV). In 53 patients who underwent minimally invasive total thyroidectomy (from January 2003 to December 2007), US-TV, obtained by ellipsoid volume formula, was compared to PS-TV determined by the Archimedes' principle. A mathematical formula able to predict the TV from the US-TV was applied in 34 cases in the last 2 years. Mean US-TV (14.4 +/- 5.9 ml) was significantly lower than mean PS-TV (21.7 +/- 10.3 ml). This underestimation was related to gland multinodularity and/or nodular involvement of the isthmus. A mathematical formula to reduce US-TV underestimation and predict the real TV was developed using a linear model. Mean predicted TV (16.8 +/- 3.7 ml) perfectly matched mean PS-TV, underestimating PS-TV in 19% of cases. We verified the accuracy of this mathematical model in patients' eligibility for minimally invasive total thyroidectomy, and we demonstrated that a predicted TV <25 ml was confirmed post-surgery in 94% of cases. We demonstrated that using a linear model, it is possible to predict from US the PS-TV with high accuracy. In fact, the mean predicted TV perfectly matched the mean PS-TV in all cases. In particular, the percentage of cases in which the predicted TV perfectly matched the PS-TV increases from 23%, estimated by US, to 43%. Moreover, the percentage of TV underestimation was reduced from 77% to 19%, as well as the range of the disagreement from up to 200% to 80%. This study shows that two

  11. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    International Nuclear Information System (INIS)

    Reinhardt, Michael J.; Joe, Alexius Y.; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger; Brink, Ingo; Krause, Thomas M.

    2002-01-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15±9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256±80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses. (orig.)

  12. Evaluation of diffuse thyroid diseases by computed tomography and 123I thyroidal uptake

    International Nuclear Information System (INIS)

    Kurihara, Yoshiko; Imanishi, Yoshimasa; Ehara, Norishige

    1991-01-01

    Understanding the iodine kinetics in the thyroid is useful for the diagnosis of a patient with diffuse thyroid disease. In this study, 9 controls and 50 patients with diffuse thyroid diseases, we evaluated diffuse thyroid diseases with 123 I thyroidal uptake and volume, iodine concentration, and net iodine content measured by computed tomography. There was no significant correlation between volume, iodine concentration, and net iodine content of the thyroid and 123 I thyroidal uptake. The thyroid volume in Graves' and Hashimoto's diseases was significantly larger than that in the control group. The thyroid iodine concentration in Graves' and Hashimoto's diseases was significantly smaller than that in the control group. The thyroid net iodine content in Hashimoto's disease was significantly smaller than that in the control group. Although most of the patients with Graves' disease had more increased radioiodine thyroidal uptake than the control group, there was no significant difference between them in the mean of the thyroid net iodine content. But the variance of net iodine contents in the former was significantly larger than that in the latter. The thyroid net iodine content was very low in all patients with very high thyroglobulin hemaggrugated antibody (TGHA) value although it was nearly normal in some patients with normal TGHA value. It was suggested that iodine concentration and net iodine content might be determined not only by iodine uptake but also by release and/or leakage of iodine compounds from the thyroid, which might depend on some antithyroid antibodies. (author)

  13. Is the sup(99m)Tc-Thyroid-uptake (TcTU) a valid measure of thyroidal trapping

    International Nuclear Information System (INIS)

    Mahlstedt, J.; Hotze, L.A.; Schwedes, H.G.; Joseph, K.

    1979-01-01

    In 2067 euthyroid goitrous patients living in an iodine deficient area which is under medical service of the university of Marburg/L. (W. Germany) sup(99m)Tc-Thyroid-Uptake as a measure for thyroidal trapping has been evaluated with respect to age and sex dependance. For both sexes there is marked decrease with increasing age, the values in the female sex are always higher than in the male sex. Comparison with the relevant results of ODDIE and coworkers reveals general correspondence, the differences of a more strong age and sex dependance are to expect in a region of iodine deficiency. Thus, the study confirms the validity of TcTU as a measure of thyroidal trapping. (orig.) [de

  14. Thyroid and Weight

    Science.gov (United States)

    ... Thyroid and Weight Thyroid and Weight FAQs THYROID, BMR & WEIGHT WHAT IS THE RELATIONSHIP BETWEEN THYROID AND ... it is known as the basal metabolic rate (BMR). Indeed, measurement of the BMR was one of ...

  15. Association of thyroid gland volume, serum insulin-like growth factor-I, and anthropometric variables in euthyroid prepubertal children

    DEFF Research Database (Denmark)

    Boas, Malene; Hegedüs, Laszlo; Feldt-Rasmussen, Ulla

    2009-01-01

    CONTEXT AND OBJECTIVE: Few studies have focused on the interrelation between thyroid size, anthropometric variables, and IGF-I in adults, but such data are lacking for children. We have investigated thyroid gland volume and several hormonal and anthropometric variables in prepubertal children...... significantly associated with TV. Family history of thyroid disease and presence of incidental abnormal ultrasound findings were also positively associated with TV (P = 0.025 and 0.022, respectively). CONCLUSIONS: In our cohort of prepubertal Danish children, the GH/IGF-I-axis was positively correlated...

  16. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    International Nuclear Information System (INIS)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-01-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment

  17. An algorithm to estimate the volume of the thyroid lesions using SPECT

    International Nuclear Information System (INIS)

    Pina, Jorge Luiz Soares de; Mello, Rossana Corbo de; Rebelo, Ana Maria

    2000-01-01

    An algorithm was developed to estimate the volume of the thyroid and its functioning lesions, that is, those which capture iodine. This estimate is achieved by the use of SPECT, Single Photon Emission Computed Tomography. The algorithm was written in an extended PASCAL language subset and was accomplished to run on Siemens ICON System, a special Macintosh environment that controls the tomographic image acquisition and processing. In spite of be developed for the Siemens DIACAN gamma camera, the algorithm can be easily adapted for the ECAN camera. These two Cameras models are among the most common ones used in Nuclear Medicine in Brazil Nowadays. A phantom study was used to validate the algorithm that have shown that a threshold of 42% of maximum pixel intensity of the images it is possible to estimate the volume of the phantoms with an error of 10% in the range of 30 to 70 ml. (author)

  18. Effect of thyroid hormone replacement therapy on ovarian volume and androgen hormones in patients with untreated primary hypothyroidism.

    Science.gov (United States)

    Muderris, Iptisam Ipek; Boztosun, Abdullah; Oner, Gokalp; Bayram, Fahri

    2011-01-01

    Primary hypothyroidism may be associated with ovarian enlargement and/ or cyst formation. We evaluated the effect of thyroid hormone replacement therapy on hormonal changes, ovarian volume and sonographic appearance. Open, prospective study of women admitted to university gynecology clinic. The study included 26 patients with untreated hypothyroidism who had polycystic (n=10) or normal-appearing (n=16) ovaries and 20 euthyroidic controls. Basal serum total testosterone, free testosterone, androstenedione, dehydroepiandosterone-sulfate, prolactin, estradiol, luteinizing hormone, follicle-stimulating hormone, free T3, free T4 and thyroid-stimulating horone, together with ovarian volumes, were determined and repeated after euthyroidism was achieved. Ovarian volumes of patients with hypothyroidism were significantly greater compared with controls, and their magnitudes diminished significantly during thyroid hormone replacement therapy. Hypothyroidic patients with polycystic ovaries had significantly higher serum free testosterone and dehydroepiandosterone-sulfate, but lower androstenodione levels compared with those who had normal-appearing ovaries. Serum total testosterone concentrations were significantly higher in hypothyroidic patients without polycystic ovaries, and thyroid hormone replacement therapy achieved a significant reduction in total as well as free testosterone. Severe longstanding hypothyroidism leads to increased ovarian volume and/or cyst formation. A decrease in ovarian volume, resolution of ovarian cysts and reversal of the polycystic ovary syndrome-like appearance, together with improvement in serum hormone levels, occurred after euthyroidism was achieved.

  19. Measurement of Thyroid Dose by TLD arising from Radiotherapy of Breast Cancer Patients from Supraclavicular Field

    Directory of Open Access Journals (Sweden)

    Farhood B.

    2016-06-01

    Full Text Available Background: Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary fields. Objective: In the present study, due to the presence of sensitive organ such as thyroid inside the supraclavicular field, thyroid dose and its effective factors were investigated. Materials and Methods: Thyroid dose of 31 female patients of breast cancer with involved supraclavicular lymph nodes which had undergone radiotherapy were measured. For each patient, three TLD-100 chips were placed on their thyroid gland surface, and thyroid doses of patients were measured. The variables of the study include shield shape, the time of patient’s setup, the technologists’ experience and qualification. Finally, the results were analyzed by ANOVA test using SPSS 11.5 software. Results: The average age of the patients was 46±10 years. The average of thyroid dose of the patients was 140±45 mGy (ranged 288.2 and 80.8 in single fraction. There was a significant relationship between the thyroid dose and shield shape. There was also a significant relationship between the thyroid dose and the patient’s setup time. Conclusion: Beside organ at risk such as thyroid which is in the supraclavicular field, thyroid dose possibility should be reduced. For solving this problem, an appropriate shield shape, the appropriate time of the patient’s setup, etc. could be considered.

  20. Effect of occupational exposure to cobalt blue dyes on the thyroid volume and function of female plate painters

    DEFF Research Database (Denmark)

    Prescott, E; Netterstrøm, B; Faber, J

    1992-01-01

    It has previously been shown that long-term oral exposure to cobalt can cause goiter and myxedema. The effect of industrial cobalt exposure on thyroid volume and function was determined for 61 female plate painters exposed to cobalt blue dyes in two Danish porcelain factories and 48 unexposed ref...

  1. Control of treatment of differentiated thyroid carcinoma by measurement of thyroglobulin in serum

    International Nuclear Information System (INIS)

    Hagemann, J.; Schneider, C.

    1978-01-01

    The presence of thyroglobulin in serum of patients with differentiated thyroid carcinoma was studied by a specific radioimmunoassay. Seventy-three patients with thyroid carcinomata were examined, 16 of whom had pulmonary or skeletal metastase, 11 local metastases, and the others no metastases. Patients with generalized metastases had very high serum thyroglobulin concentrations while those with local metastases had slightly elevated or normal concentrations. Those with remaining thyroid tissue had mainly normal thyroglobulin levels and patients with neither metastases nor remaining thyroid tissue had undetectable serum thyroglobulin. In seven patients with metastases it was possible to observe the development of serum thyroglobulin after 131 I treatment. In all cases the serum thyroglobulin concentration paralleled the development of the clinical status. Elevated serum thyroglobulin was also found in benign thyroid diseases such as hyperthyroidism and endemic goitre. Measurement of thyroglobulin in serum is therefore of little value in differentiating between benign and malignant thyroid diseases, but it is a good method for the follow-up control of patients with differentiated thyroid carcinomata. Because normal thyroglobulin levels do not exclude local metastases, additional examinations are necessary if normal thyroglobulin levels are found. When thyroglobulin is undetectable, metastases can be excluded and the measurement of thyroglobulin in serum can replace all other methods in the follow-up control. (author)

  2. Establishing construct validity for the thyroid-specific patient reported outcome measure (ThyPRO)

    DEFF Research Database (Denmark)

    Watt, Torquil; Bjorner, Jakob Bue; Groenvold, Mogens

    2009-01-01

    OBJECTIVE: To establish a reliable and valid scale structure of a patient-reported outcome measuring thyroid-specific quality of life. METHODS: The 98-item ThyPRO questionnaire was administered to patients with benign thyroid diseases at two university hospitals. Multi-trait scaling was performed...... symptoms and psychological and disease-impact scales. Cronbach's alpha was acceptable (>0.70, >0.80 with polychoric correlations) for all 13 scales. CONCLUSION: A reliable scale structure displaying complete convergent and almost complete discriminant validity was established in general analyses...... and in distinct clinical subgroups of patients with benign thyroid diseases....

  3. Thyroid Diseases

    Science.gov (United States)

    ... your thyroid gland does not make enough thyroid hormones Thyroid cancer Thyroid nodules - lumps in the thyroid gland Thyroiditis - swelling of the thyroid To diagnose thyroid diseases, doctors use a medical history, physical exam, and thyroid tests. They sometimes also ...

  4. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Michael J.; Joe, Alexius Y.; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger [Department of Nuclear Medicine, University Hospital of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Brink, Ingo [Department of Nuclear Medicine, University Hospital of Freiburg (Germany); Krause, Thomas M. [Department of Nuclear Medicine, Inselspital Bern (Switzerland)

    2002-09-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15{+-}9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256{+-}80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses

  5. Routine calcitonin measurement in nodular thyroid disease management: is it worthwhile?

    Science.gov (United States)

    Turk, Yigit; Makay, Ozer; Ozdemir, Murat; Ertunc, Gozde; Demir, Batuhan; Icoz, Gokhan; Akyildiz, Mahir; Yilmaz, Mustafa

    2017-04-01

    To evaluate the diagnostic accuracy of routine calcitonin measurement in patients with nodular thyroid disease. Consecutive patients with nodular thyroid disease (n = 640) were studied. Serum calcitonin levels were measured under basal conditions, and when basal values were between 10-100 pg/mL, testing was repeated after pentagastrin (PG) stimulation. Patients with previously diagnosed or familial medullary thyroid cancer (MTC) were excluded. Patients were operated on when basal or stimulated calcitonin >100 pg/mL or when other surgical indications were present. Four cases of MTC were identified. MTC was diagnosed in 75% of patients with basal calcitonin >100 pg/mL. One out of 11 patients with basal calcitonin between 10-100 pg/mL was diagnosed with MTC. PG stimulation resulted in elevation in 4 cases, where 1 case was diagnosed with MTC. Positive predictive value for basal calcitonin levels in the preoperative diagnosis of MTC was 5% for values between 10-100 pg/mL and 100% for values >100 pg/mL. Possible reasons for false positivity were papillary thyroid cancer in 17%, renal insufficiency in 8.3%, Hashimoto thyroiditis in 17% and β-blocker use in 33%. Positive predictive value for the PG test (>100 pg/mL) was 25% in the entire series. The cost of adding calcitonin measurement (±PG stimulation) to the preoperative work-up, resulted in €912.68 per MTC patient to detect the disease. Basal calcitonin measurement together with PG stimulation in cases of basal calcitonin >10 pg/mL detects MTC in 0.62% of patients with nodular thyroid disease.

  6. Radioimmunoassay measurements of serum thyrotropin in patients with hypothalamic-pituitary and thyroid diseases

    International Nuclear Information System (INIS)

    Miyai, Kiyoshi; Azukizawa, Mizuo; Azukizawa, Hisako; Hosokawa, Mitsuko; Nishi, Keiko

    1975-01-01

    Serum TSH was measured by means of double antibody radioimmunoassay using a commercial Kit Daiichi, in 21 normal subjects, 200 patients with thyroid disease and 130 patients with hypothalamic-pituitary diseases. Serum TSH concentrations in normal subjects were <2 to 8 μU/ml which rose to 8-40 μU/ml after administration of 500 μg TRH intravenously. Serum TSH was undetectable and did not respond to TRH in all untreated patients and in some euthyroid patients with Graves' disease after treatment. Undetectable TSH and no response to TRH were also observed in most patients with a hyperfunctioning thyroid nodule and those with subacute thyroiditis in the acute phase. In some patients with Hashimoto's thyroiditis and all patients with adult myxedema and cretinism, serum TSH levels were increased and showed hyperresponse to TRH. The ratio of bioassay and radioimmunoassay potency estimates for TSH in sera obtained before TRH was not statistically different from that obtained after TRH administration to patients with primary hypothyroidism. Elevated serum TSH was promptly decreased by the administration of thyroid hormone to the patients. More than 50% of patients with pituitary adenoma, acromegaly and craniopharyngioma showed normal basal TSH and no or low response of TSH to TRH. Administration of TRH failed to stimulate a rise in serum TSH in 2 sisters with isolated TSH deficiency with cretinism. Basal TSH was undetectable and showed delayed response to TRH in patients with anorexia nervosa. (auth.)

  7. Thyroid γ ray measurement after iodine-131 therapy for Graves' disease

    International Nuclear Information System (INIS)

    Liu Jianfeng; Guo Qingling; Ye Genyao; Li Xin; Wang Anyu; Wang Ying; Zhu Hui; He Ling; Yuan Chao

    2004-01-01

    Objective: To study the thyroid 131 I uptake within 24 hours following 131 I therapy for Graves' disease. Methods: Eighteen hyperthyroidism patients were divided into two groups according to thyroid weight and radiotherapy dosage. Low-dose group and high-dose group received the mean dose 162.8 MBq (4.4 mCi) and 255.3 MBq (6.9 mCi), respectively. The γ ray dose rates from thyroids were measured in all patients at 1, 2, 4, 8,12 and 24 h after 131 I therapy. Results: γ ray dose rates were elevated rapidly at 1 hour and continued at high level between 2-12 h and slowly fell in 24 h after 131 I therapy. γ Rat curve of low-dose group was lower than that of high-dose group. Conclusion: There was a rapid absorption and concentration period in 1 h and slow metabolism and release period after 12 h in thyroid following radioiodine therapy of Graves' disease. The thyroids of hyperthyroidism patients displayed different γ ray curves. (author)

  8. Normal values of thyroid gland in Isfahan, an iodine replete area

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2008-04-01

    Full Text Available

    • BACKGROUND: Because of different values of thyroid volume in different populations, and the effects of different trace element and geographic substances on thyroid volume, we decided to evaluate thyroid volume and its determinants using ultrasound in healthy adults of Isfahan, a centrally located city in Iran, an iodine replete area.
    • METHODS: In a cross-sectional study, 1500 healthy adults were enrolled by cluster sampling. Serum TSH level and morning urine iodine level were measured. Thyroid exam was performed according to WHO criteria and history of previous or present thyroid disease was taken. If all the mentioned results were normal they were considered clinically normal. One third of these normal subjects referred for thyroid ultrasonography. If ultrasonography of thyroid parenchyma texture was normal, and there was no nodule by sonography (thyroid incidentaloma, thyroid volume was measured using ellipsoid formula (X×Y×Z×8/6. Correlation between thyroid volume and age, sex, BMI, TSH level and urinary iodine concentration (UIC was determined by Pearson correlation coefficient, t-Test and Kolmogorov-Smirnov. Thyroid volume more than 97% of this population was considered as goiter sonographically. Data expressed as mean ± SD, unless otherwise stated.
    • RESULTS: We finally studied 200 subjects (123 Males, 77 females, average age: 37.27 ± 11.80 Years. The overall thyroid volume was 9.53 ± 3.68 ml. Males thyroid volume (10.73 ± 3.44 ml was significantly higher than the females one (7.71 ± 2.63 ml (P < 0.001. The thyroid volume ranges were 3-23.9 ml, 3.6-23.9 ml and 3-14.3 ml in all, males and females, respectively. Thyroid volume values more than 97 percentile of this reference range were 10.14 ml, 11.48 ml and 8.37 ml in all, males and females respectively, and were considered goiter sonographically. Thyroid volume had a positive correlation with age (r = 0.163, P

    • Exposure to pyrethroids insecticides and serum levels of thyroid-related measures in pregnant women

      Energy Technology Data Exchange (ETDEWEB)

      Zhang, Jie; Hisada, Aya [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Yoshinaga, Jun, E-mail: junyosh@k.u-tokyo.ac.jp [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Shiraishi, Hiroaki [National Institute for Environmental Studies, Onogawa 16-2, Tsukuba, Ibaraki 305-8563 (Japan); Shimodaira, Kazuhisa; Okai, Takashi [Department of Obstetrics and Gynecology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan); Noda, Yumiko; Shirakawa, Miyako; Kato, Nobumasa [Department of Psychiatry and Neurology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan)

      2013-11-15

      Possible association between environmental exposure to pyrethroid insecticides and serum thyroid-related measures was explored in 231 pregnant women of 10–12 gestational weeks recruited at a university hospital in Tokyo during 2009–2011. Serum levels of free thyroxine (fT4), thyroid stimulating hormone (TSH) and thyroid biding globulin (TBG) and urinary pyrethroid insecticide metabolite (3-phenoxybenzoic acid, 3-PBA) were measured. Obstetrical information was obtained from medical records and dietary and lifestyle information was collected by self-administered questionnaire. Geometric mean concentration of creatinine-adjusted urinary 3-PBA was 0.363 (geometric standard deviation: 3.06) μg/g cre, which was consistent with the previously reported levels for non-exposed Japanese adult females. The range of serum fT4, TSH and TBG level was 0.83–3.41 ng/dL, 0.01–27.4 μIU/mL and 16.4–54.4 μg/mL, respectively. Multiple regression analysis was carried out by using either one of serum levels of thyroid-related measures as a dependent variable and urinary 3-PBA as well as other potential covariates (age, pre-pregnancy BMI, parity, urinary iodine, smoking and drinking status) as independent variables: 3-PBA was not found as a significant predictor of serum level of thyroid-related measures. Lack of association may be due to lower pyrethroid insecticide exposure level of the present subjects. Taking the ability of pyrethroid insecticides and their metabolite to bind to nuclear thyroid hormone (TH) receptor, as well as their ability of placental transfer, into consideration, it is warranted to investigate if pyrethroid pesticides do not have any effect on TH actions in fetus brain even though maternal circulating TH level is not affected. -- Highlights: • Pyrethroid exposure and thyroid hormone status was examined in pregnant women. • Urinary 3-phenoxybenzoic acid was used as a biomarker of exposure. • Iodine nutrition, age and other covariates were included

    • Thyroid iodine content measured by x-ray fluorescence in amiodarone-induced thyrotoxicosis: concise communication

      Energy Technology Data Exchange (ETDEWEB)

      Leger, A.F.; Fragu, P.; Rougier, P.; Laurent, M.F.; Tubiana, M.; Savole, J.C.

      1983-07-01

      Iodine-induced thyrotoxicosis (IiT) is characterized by (a) a low radioiodine uptake, increased by exogenous TSH, and (b) a spontaneous evolution towards cure within a few months. An hypothetical pathogenesis of IiT is an initial inflation in the stores of thyroid hormones during iodine excess, followed by their sudden discharge into the circulation. Thyroid iodine content was measured by fluorescent scanning in 10 patients with amiodarone-induced thyrotoxicosis and in various control groups. Results were found to be high at the onset of the disease and to decrease during its course. The data agree with the hypothetical pathogenesis. Furthermore they may permit exclusion of a painless subacute thyroiditis, which is the main differential diagnosis of IiT.

    • The Analysis of the Value of the Thyroid Autoantibody Measured by Radioimmunoassay

      International Nuclear Information System (INIS)

      Chung, Jae Hoon; Lee, Myung Shik; Cho, Bo Youn; Lee, Hong Kyu; Koh, Chang Soon; Min, Hun Ki; Lee, Mun Ho

      1987-01-01

      To evaluate the values of the thyroid autoantibody measured by radioimmunoassay (RIA) and compare it with hemagglutination method (HA) in the normal and the thyroid disease, data were obtained from total 618 persons; 236 healthy persons, 217 patients with Graves disease (including 113 patients with undertreated Graves' disease), 100 Hashimoto's disease, 31 thyroid nodule, and 34 simple goiter. RSR kit made in England was used and could be detected at least 3 U/ml. The positive rates of normal group were antirnicrosomal antibody (AMA) 31.8%, antithyroglobulin antibody (ATA) 44.5% by RIA and there was no considerable change in sex and age distribution. In Graves disease, the positive rates of AMA and ATA were 90.4, 76.9% by RIA, 85, 39% by HA. In Hashimoto's disease, 94,91% by RIA, and 87,48% by HA, respectively. The autoantibody titer by RIA in thyroid autoimmune disease as welt as in normal group was more sensitive than that by HA, especially in ATA. There were linear relationships between the titer of RIA and that of HA in AMA of Graves disease and AMA and ATA of Hashimotos disease. There was no relationship among thyroid autoantibody, free T, index, TBII, and TSH. The titers of AMA and ATA were found to decrease in patients with Graves disease during the course of antithyroid drug therapy. Of the 236 normal subjects, thirty-seven (15.7%) had concentrations of above 7.5 U/ml in AMA, forty-four (18. 6%) above 9 U/ml in ATA. These values were considered as the upper limit for the normal range. In Graves disease, 82,7, 53.8% were above 7.5, 9 U/ml, respectively; In Hashimoto's disease, HZ, 79% were positive. We conclude that RIA was more sensitive than HA in measuring the thyroid autoantibody, but we will study further more for determining the normal range and its interpretation.

    • Reliability and accuracy of the 131I thyroid activity measurements performed in the Ukraine after the Chernobyl accident in 1986

      International Nuclear Information System (INIS)

      Likhtarev, I.A.; Gulko, G.M.; Kairo, I.A.; Sobolev, B.G.; Chepurnoy, N.I.; Cheban, A.K.; Nikonov, D.A.; Djachkov, I.A.; Proehl, G.

      1993-06-01

      A statistical analysis of the measurements of the reference sources used for the calibration of the devices was performed in order to determine calibration factors for the used devices. High quality data sets are selected which can be used for the thyroid dose assessment of people not being monitored and for the derivation of correction factors for low quality measurements. The uncertainties due to the variability of the age-dependent thyroid mass, the thickness of the overlying tissue, and the position of the detector relative to the thyroid have been quantified. A neck-thyroid phantom is used to determine the dependence of the measured activity from these parameters. The real variability of thyroid masses and of the thickness of the overlying tissues is estimated for the population of Kiev. The results give quantitative information about the influence of those parameters on the reliability of the activity measurements. (orig.)

    • Manufacture of a simulator for in vitro measurements of iodine in thyroids

      International Nuclear Information System (INIS)

      Cruz Suarez, R.; Lopez Bejerano, G.M.; Carrazana Gonzalez, J.A.

      1993-01-01

      The technique for a construction of a thyroid simulator which permit the efficient detection system calibration for in vivo measurements of iodine in that organ, as well as calibration methods for the assessment of the amount of radioactive iodine incorporated into the body

    • Importance of thyroglobulin measurement at radioiodine thyroid remnant ablation stimulated by recombinant TSH in patients with differentiated thyroid carcinoma

      International Nuclear Information System (INIS)

      Paz-Filho, Gilberto; Carvalho, Gisah; Graf, Hans

      2005-01-01

      Full text: Radioiodine remnant ablation (RRA) after total or near-total thyroidectomy for differentiated thyroid carcinoma (DTC) is adopted routinely by our department. Recombinant TSH (rh TSH) is an alternative for patient preparation for RRA, as effective as RRA after thyroid hormone withdrawal. Thyroglobulin (Tg) dosage at RRA may be important for the follow-up of DCT. To evaluate the predictive value of serum Tg for metastatic disease in patients submitted to rh TSH before RRA, 29 consecutive patients (25 female, 4 male; mean age 38 ± 13 years) with DCT (28 papillary and 1 follicular) were submitted to RRA with 100 to 150 mCi after receiving rh TSH (2 x 0.9 mg). Serum values of TSH, Tg and anti-thyroglobulin (TgAb) were measured before and 24 hours after rh TSH, and 48 hours after RRA. Whole-body radioiodine scan (RxWBS) was performed 4 to 7 days after RRA. Conclusion: RxWBS revealed thyroid remnants (TR) in 75.9% (n=22, Group 1), lymph node metastasis in 17.2% (n=5, Group 2) and pulmonary metastasis in 6.9% (n=2, Group 3). Positive TgAb prevalence was found in 31% of all patients (n=9). Considering TgAb-negative subjects, basal median Tg levels were 0.2 ng/ml (0.08-3.89) in Group 1, 2.86 ng/ml (0.01-12.24) in Group 2 and 5.27 ng/ml in Group 3 (only one patient in Group 3 had pulmonary metastasis and negative TgAb). Median peak Tg levels after rh TSH at 131 I RRA were significantly lower in Group 1 (1.6 ng/ml) than in Group 2 (18.7 ng/ml) and in Group 3 (90.8 ng/ml) and between Group 2 and 3 combined (19.8 ng/ml). In conclusion, elevated Tg levels before rh TSH and at RRA could suggest the presence and the extension of metastatic disease observed at the RxWBS, in patients with DTC. Further studies should be designed to fully examine this relationship. (author)

    • Data quality and practical challenges of thyroid volume assessment by ultrasound under field conditions - observer errors may affect prevalence estimates of goitre

      Directory of Open Access Journals (Sweden)

      Torheim Liv E

      2010-12-01

      Full Text Available Abstract Background The ultrasonographic estimation of thyroid size has been advocated as being more precise than palpation to diagnose goitre. However, ultrasound also requires technical proficiency. This study was conducted among Saharawi refugees, where goitre is highly prevalent. The objectives were to assess the overall data quality of ultrasound measurements of thyroid volume (Tvol, including the intra- and inter-observer agreement, under field conditions, and to describe some of the practical challenges encountered. Methods In 2007 a cross-sectional study of 419 children (6-14 years old and 405 women (15-45 years old was performed on a population of Saharawi refugees with prevalent goitre, who reside in the Algerian desert. Tvol was measured by two trained fieldworkers using portable ultrasound equipment (examiner 1 measured 406 individuals, and examiner 2, 418 individuals. Intra- and inter-observer agreement was estimated in 12 children selected from the study population but not part of the main study. In the main study, an observer error was found in one examiner whose ultrasound images were corrected by linear regression after printing and remeasuring a sample of 272 images. Results The intra-observer agreement in Tvol was higher in examiner 1, with an intraclass correlation coefficient (ICC of 0.97 (95% CI: 0.91, 0.99 compared to 0.86 (95% CI: 0.60, 0.96 in examiner 2. The ICC for inter-observer agreement in Tvol was 0.38 (95% CI: -0.20, 0.77. Linear regression coefficients indicated a significant scaling bias in the original measurements of the AP and ML diameter and a systematic underestimation of Tvol (a product of AP, ML, CC and a constant. The agreement between re-measured and original Tvol measured by ICC (95% CI was 0.76 (0.71, 0.81. The agreement between re-measured and corrected Tvol measured by ICC (95% CI was 0.97 (0.96, 0.97. Conclusions An important challenge when using ultrasound to assess thyroid volume under field

    • The place occupied by early measurement (20th minute) of the thyroid uptake of sup(99m)Tc pertechnetate in thyroid pathology

      International Nuclear Information System (INIS)

      Guilloteaux, Gerard.

      1977-01-01

      The place occupied by early measurement (20th minute) of the thyroid uptake of sup(99m)Tc pertechnetate is situated for different types of thyroid condition (hypo-, normo- and hyperthyroidism). The use of technetium is simple in practice because only the cervical and crural radioactivity measurements are required. Like all simplified methods it involves risks of errors but lends itself to systematic routine use. The practical advantages of this isotope, which in view of its short half-life appears with iodine 123 as the nearly ideal tracer for thyroid exploration at present are outlined. The thyroid gland can be studied both functionally and scintigraphically at the cost of minimum irradiation, which is a great advantage. The fact that a number of data may be obtained in less than an hour (including scintigraphy) is a particularly valuable asset. However the method has its limits. For example a diagnosis of hyper or hypothyroidism based on the technetium uptake at the 20th minute alone is out of the question. A zero uptake may be observed in the presence of Basedow's disease or conversely a high uptake in hypo- or euthyroid cases. Discrimination is satisfactory between hyper and euthyroid but not between eu- and hypothyroid subjects. Technological progress however promises a routine use of 123 I and 99mTc together, the two isotopes serving to explore two different phases of the thyroid metabolism [fr

    • Effect of a mandatory iodization program on thyroid gland volume based on individuals' age, gender, and preceding severity of dietary iodine deficiency: A prospective, population-based study

      DEFF Research Database (Denmark)

      Vejbjerg, Pernille; Knudsen, Nils; Perrild, Hans

      2007-01-01

      volume in the age groups younger than 45 yr. When adjusted for confounders, a lower mean volume was seen among those with multiple nodules in both areas and in the group with diffuse structure in the area with moderate iodine deficiency. Before the iodization, 17.6% of the total cross-section had thyroid...

    • Measurable inhomogeneities in stock trading volume flow

      Science.gov (United States)

      Cortines, A. A. G.; Riera, R.; Anteneodo, C.

      2008-08-01

      We investigate the statistics of volumes of shares traded in stock markets. We show that the stochastic process of trading volumes can be understood on the basis of a mixed Poisson process at the microscopic time level. The beta distribution of the second kind (also known as q-gamma distribution), that has been proposed to describe empirical volume histograms, naturally results from our analysis. In particular, the shape of the distribution at small volumes is governed by the degree of granularity in the trading process, while the exponent controlling the tail is a measure of the inhomogeneities in market activity. Furthermore, the present case furnishes empirical evidence of how power law probability distributions can arise as a consequence of a fluctuating intrinsic parameter.

    • Flow rate measurement in a volume

      Energy Technology Data Exchange (ETDEWEB)

      Galvez, Cristhian

      2018-04-17

      A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate of the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.

    • Does 131I-treatment of goitre result in an acute increase in the volume a function of the thyroid gland?

      International Nuclear Information System (INIS)

      Nygaard, B.; Faber, J.O.; Hegedues, L.

      1995-01-01

      Many textbooks claim that radioiodine ( 131 I) treatment should be avoided in treatment of a goitre with substernal extension, due to fear of acute swelling of the gland with resulting respiratory problems. We examined patients with multinodular goitre, either nontoxic (n=20) or toxic (n=10) after treatment with 131 I. An ultrasonically determined thyroid volume and thyroid function variables were investigated before and two, seven, 14, 21, 28 and 35 days after treatment. In nontoxic goitres the thyroid volume did not increase significantly, the maximum increase in the median volume being 4% on day 7. Serum levels of free T 3 and free T 4 indices increased by 20% (day 7) and 13% (day 14) (p=0.002), respectively. Likewise thyroid volume in toxic nodular goitre did not change significantly after 131 I treatment. None of the patients presented symptoms of tracheal compression. We conclude that 131 I treatment of nontoxic as well as toxic multinodular goitre does not seem to increase thyroid volume. (au) 18 refs

  1. Validation of a technique of measurement in vivo of 131I in thyroids

    International Nuclear Information System (INIS)

    Villella, A.M.; Puerta Yepes, N.; Gossio, S.; Papadopulos, S.

    2010-01-01

    The Total Body Counter (TBC) Laboratory of the Nuclear Regulatory Authority, following the institutional initiative of quality assurance in its measurement techniques, has been involved in an accreditation process based on the ISO/IEC 17205:2005 norm. In vivo measurement of 131 I in thyroid has been selected as the first technique in this process, and it is described in this paper. The TBC Laboratory uses for this technique a gamma spectrometry system with a NaI(Tl) detector, calibrated with a neck simulator of the IRD and a certified plane source of 131 I with thyroid form. It has been carried out a validation plan that has permitted the characterization of the 131 I measurement technique, and its uncertainty evaluation. Measurement parameters that affect the uncertainty are discussed and recommendations for the technique optimization are proposed. (authors) [es

  2. Liquid volumes measurements by isotopic dilution

    International Nuclear Information System (INIS)

    Herrera M, J.M.

    1981-01-01

    By the nuclear technique, isotopic dilution industrial liquid volumes may be measured in large size recipients of irregular shapes using radiotracers. In the present work laboratory and pilot test are made with 2 radiotracers for optimizing the technique and later done on an industrial scale, obtaining a maximum deviation of +-2%, some recommendations are given to improve the performance of the technique. (author)

  3. Thyroid mass estimation in Grave's disease by SPECT

    International Nuclear Information System (INIS)

    Pant, G.S.; Sharma, S.K.; Kumar, R.; Pandey, A.K.; Gupta, A.K.

    2002-01-01

    Aim: One of the important parts of treatment of Grave's disease with I-131 is the delivery of accurate dose to the target volume. Three important parameters that need to be accurately measured for dosimetry are; the 24 hr thyroid uptake (%), the thyroid mass and effective half life of I-131 in the gland. In this presentation we describe the estimation thyroid mass by SPECT. We have standardised a method to estimated thyroid volume by SPECT using thyroid phantoms of different sizes and then used them for routine thyroid mass estimation in patients with Graves' disease. Materials and Methods: Due to variation in thyroid weight in patients with Grave's disease, we standardised the scintigraphic (SPECT) technique using thyroid phantoms of different volumes such as 5 ml, 9.5 ml, 10.5 ml, 35 ml, 80 ml, 101ml and 110 ml. Each phantom was filled with 99 mTc solution with different activity concentration (100 μCi, 300 μCi, 600 μCi and 1.0 μCi) and SPECT images were acquired on a VARICAM dual head camera in 128x128 matrix. The acquired data was processed using a standardised Metz filter but without attenuation or scatter correction. Coronal slices were used with suitable threshold for edge detection. An irregular ROI was plotted around each lobe and isthmus of the thyroid gland and the enclosed slice area was measured. The area measured from all the frames was added and multiplied by the slice thickness to get the volume of the thyroid gland. The estimated volume of each phantom was compared and correlated with its actual volume. The thyroid mass in 40 patients was estimated by SPECT and compared with that estimated by ultrasonography.Results and Conclusion: The results of thyroid mass estimation with SPECT in phantom study suggested a 30% threshold for all phantom volumes. However, 35% threshold was used in patients' images for estimating thyroid volume. The estimated volumes by scintigraphy were compared with that estimated by ultrasonography. A correlation coefficient

  4. Detection system qualification for direct measurement of thyroid internal contamination by radioiodine

    International Nuclear Information System (INIS)

    Tiberi, V.; Battisti, P.; Gualdrini, G.

    1999-01-01

    The work deals with a detection system qualification for direct measurements of thyroid internal contamination by radioiodine. The isotopes 131 I and 125 I are the most frequently used in nuclear medicine. Because of their volatility they are very dangerous for thyroid contamination by inhalation. The system has been projected to be easily and fast used and above all transportable where the control is necessary. These characteristic make it able to realise supervision programs of internal contamination by radioiodine. In fact due the very high control frequencies (each 15 days for 131 I), these programs are usually very expensive and demanding when they are executed in external measurement laboratories. The following steps are described: devices presentation, calculation of energy and efficiency parameters, minimum detectable activity, time system reliability, best operative conditions in the measurements. At the end an application example of the system is reported [it

  5. Benefit of measuring basal serum calcitonin to detect medullary thyroid carcinoma in a Danish population with a high prevalence of thyroid nodules

    DEFF Research Database (Denmark)

    Hasselgren, Martin; Hegedüs, Laszlo; Godballe, Christian

    2009-01-01

    BACKGROUND: Routine measurement of serum calcitonin to detect medullary thyroid carcinoma (MTC) continues to be fiercely debated, although less attention has been paid to the positive predictive value (PPV) of this method. METHODS: We collected data from 959 patients with nontoxic nodular goiter...

  6. Theoretical calibration of a NaI(Tl) detector for the measurement of 131I in a thyroid phantom

    International Nuclear Information System (INIS)

    Venturini, Luzia

    2002-01-01

    This paper describes the theoretical calibration of a NaI(Tl) detector using Monte Carlo Method, for the measurement of 131 I in a thyroid phantom. The thyroid is represented by the region between two concentric cylinders, where the inner one represents the trachea and the outer one represents the neck. 133 Ba was used for experimental calibration. The results shows that the calibration procedure is suitable for 131 I measurements. (author)

  7. Dermatitis herpetiformis is associated with atrophic but not with goitrous variant of Hashimoto's thyroiditis.

    Science.gov (United States)

    Zettinig, G; Weissel, M; Flores, J; Dudczak, R; Vogelsang, H

    2000-01-01

    Dermatitis herpetiformis (DH) is a gluten-sensitive skin disease that is associated with a variety of autoimmune disorders. Several investigations demonstrated an association between DH and autoimmune thyroid disease. However, it has not been shown if DH is associated with atrophic or goitrous variant of Hashimoto's thyroiditis. We investigated a cohort of 41 DH patients (18 male, 23 female) and a control group (11 male, 19 female; sex and age matched healthy volunteers) to find out which variant of Hashimoto's thyroiditis is associated with DH. All patients had thyroid hormones and antibodies measured. In addition to that, thyroid sonography as well as detailed history-taking of previous thyroid disease were performed. In the control group no individual with elevated levels of thyroid antibodies nor abnormal thyroid hormones nor thyroid atrophy was found. Median thyroid volume in the control group was 11 mL (range 4.8-24.7 mL). However, in nine DH patients (22%) elevated levels of antithyroid microsomal (TM) antibodies were seen (P hypothyroidism had a thyroid volume < 7 mL. Goitrous variant of Hashimoto's thyroiditis was not seen in any of the DH patients. Our findings demonstrate that DH is associated with atrophic but not with goitrous variant of Hashimoto's thyroiditis.

  8. Proposal for dose measurement in the crystalline lens and thyroid in computerized tomography of paranasal sinuses

    International Nuclear Information System (INIS)

    Mello, Ana Caroline; Machado Neto, Vicente

    2014-01-01

    With the evolution of diagnostic imaging equipment, a computerized tomography (CT) has become one of the most used tests to assess pathologies affecting the paranasal sinuses. This work aims at presenting a method of obtaining measurements of dose in the eye lenses and thyroid, from the execution of CT of the paranasal sinuses protocol. Experimental procedure will be used in an object simulator (phantom) head and neck made with accessible materials and thermoluminescent dosimeters (TLDs) of LiF: Mg,Ti for the absorbed dose in the regions of interest, when exposed to radiation in a CT scanner 16 channels. After the dosimetric evaluation with phantom use, this methodology will be applied in vivo, or in patients with medical request for the examination and approval by the Ethics Committee. Thus, at the end of this survey protocols and actions aimed at reducing the absorbed dose in the eye lenses and thyroid without impairing the diagnostic image quality can be proposed. (author)

  9. Serum thyroxine and age - rather than thyroid volume and serum TSH - are determinants of the thyroid radioiodine uptake in patients with nodular goiter

    DEFF Research Database (Denmark)

    Bonnema, S J; Fast, S; Nielsen, V E

    2011-01-01

    Background: 131I therapy is widely used for treatment of non-toxic goiters. A limitation for this treatment is a low thyroid radioiodine uptake (RAIU), often encountered in these patients. Aim: To estimate the impact of various factors on the thyroid RAIU. Methods: We examined prospectively 170 p...

  10. Thyroid-stimulating immunoglobulins in Hashimoto's thyroiditis measured by radioreceptor assay and adenylate cyclase stimulation and their relationship to HLA-D alleles

    International Nuclear Information System (INIS)

    Bliddal, H.; Bech, K.; Feldt-Rasmussen, U.; Thomsen, M.; Ryder, L.P.; Hansen, J.M.; Siersbaek-Nielsen, K.; Friis, T.

    1982-01-01

    The relationship between thyroid-stimulating immunoglobulins, measured by both radioreceptor assay and adenylate cyclase stimulation, and the HLA alleles was studied in 41 patients with Hashimoto's thyroiditis. TSH binding-inhibiting immunoglobulins (TBII) were detected in 9 (22%) patients, and human thyroid adenylate cyclase-stimulating immunoglobulins (HTACS) were found in 21 (51%) patients. Only 2 patients were positive in both assays, and an inverse relationship was observed between TBII and HTACS. In the 21 HTACS-positive patients, HLA-Dw5 was found in 1 subject, compared to 8 of the 20 HTACS-negative patients (P < 0.01), while 4 of the 9 TBII-positive patients had HLA-Dw5 compared to 5 of the 32 TBII-negative subjects (P = 0.09).No significant relations were observed between the presence of HTACS or TBII and HLA-Dw3 or HLA-B8. It is concluded that TBII and HTACS are produced independently in Hashimoto's thyroiditis, and that the production of these autoantibodies seems to be related to the HLA-D region in this disease

  11. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan ... for several hours before your exam because eating can affect the accuracy of the uptake measurement. Jewelry ...

  12. Measurements of hair volume by laser stereometry.

    Science.gov (United States)

    McMullen, Roger; Zisa, Franco; Jachowicz, Janusz

    2009-01-01

    A three-dimensional laser stereometer was constructed utilizing an x-y two-dimensional translational stage and a laser device, which provides distance information in the z-direction. The distance data is obtained by triangulation of the reflecting red laser beam from the surface of the measured object, in this case hair. Since hair fiber assemblies do not have a continuous solid surface, each z-dimension reading is obtained as an average of measurements obtained from multiple reflections corresponding to fibers at various depths below the outermost hair surface. We demonstrate the utility of this technique to perform the analysis of either an entire hair tress or relatively short sections of tresses prepared from straight, curly, and frizzy hair and subjected to cosmetic treatments such as washing, conditioning, dyeing, etc. An interpretation is provided for the three-dimensional images of hair assemblies as well as for the calculated volume of space occupied by a hair tress. In addition, we investigated various strategies for testing the volume retention of styling polymers.

  13. Does normal thyroid gland by ultrasonography match with normal serum thyroid hormones and negative thyroid antibodies?

    Science.gov (United States)

    Trimboli, P; Rossi, F; Condorelli, E; Laurenti, O; Ventura, C; Nigri, G; Romanelli, F; Guarino, M; Valabrega, S

    2010-10-01

    Few papers have shown that a hypoechoic appearance of the thyroid gland at ultrasonography (US) is related to a hypofunction and serum positivity of thyroid antibodies (T-Ab). However, it is not ascertained if normal thyroid appearance at US correspond to normal thyroid laboratory tests. The aim of this study was to assess the value of normal thyroid at US in predicting normal thyroid hormones and negative T-Ab in a cohort of 48 adult patients. All patients (37 females and 11 males) were referred to our hospital to undergo their first thyroid US examination, followed by a thyroid function evaluation. All subjects had normal thyroid gland at US. As a control group 65 patients with hypoechoic and inhomogeneous thyroid gland were enrolled. All 48 patients had normal free-T (3) and free-T (4) levels. While 41 patients (85.4%) showed normal TSH, in 7 subjects (14.6%) TSH was elevated and a significant (p thyroid volume or BMI. The multivariate model showed that only BMI was significantly correlated to thyroid volume (p thyroid recorded by US matches with normal thyroid laboratory assessment to a large degree. These preliminary data need to be confirmed in a prospective study and in a larger series and should suggest the evaluation of thyrotropin and thyroid antibodies in subjects with normal thyroid gland as assessed by US. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York.

  14. The incidence and mechanism of sunitinib-induced thyroid atrophy in patients with metastatic renal cell carcinoma.

    Science.gov (United States)

    Shinohara, N; Takahashi, M; Kamishima, T; Ikushima, H; Otsuka, N; Ishizu, A; Shimizu, C; Kanayama, H; Nonomura, K

    2011-01-18

    To elucidate the incidence and mechanisms of sunitinib-induced thyroid atrophy, we investigated serial volumetric and functional changes, and evaluated histological changes of the thyroid gland in metastatic renal cell carcinoma patients who received sunitinib. Thyroid volume (by computed tomography volumetry) and thyroid function were measured at baseline, during the treatment, and at post-treatment periods. Histological evaluation of the thyroid gland was performed in four autopsied patients. The median reduction rate in thyroid volume at last evaluation during sunitinib treatment was 30% in all 17 patients. The incidence of hypothyroidism during sunitinib treatment was significantly higher in the high reduction rate group (n=8; more than 50% reduction in volume) than in the low reduction rate group (n=9; less than 50% reduction in volume). Half of the patients in the high reduction rate group exhibited a transient thyroid-stimulating hormone suppression, suggesting thyrotoxicosis during sunitinib treatment. Histological evaluation demonstrated atrophy of thyroid follicles and degeneration of follicular epithelial cells without critical diminution of vascular volume in the thyroid gland. Thyroid atrophy is frequently observed following sunitinib treatment and may be brought about by sunitinib-induced thyrotoxicosis or the direct effects of sunitinib that lead to degeneration of thyroid follicular cells.

  15. Radioimmunoassay for calcitonin gene-related peptide and its measurement in sera of patients with thyroid disease

    International Nuclear Information System (INIS)

    Yoshida, Hiromi; Morii, Hirotoshi; Hamada, Noboru; Noh, Jaeduk; Ito, Kunihiko.

    1992-01-01

    To investigate serum levels of calcitonin gene-related peptide (CGRP), we developed a sensitive radioimmunoassay (RIA). RIA for CGRP in serum can present problems: the serum may degradate the tracer during incubation and suppress the antigen-antibody reaction. We avoided these problems by using aprotinin and CGRP-free serum instead of a buffer for the standard curve. We detected serum CGRP in all 39 healthy subjects when CGRP-free serum was not used for the standard curve, but 34 of these subjects had serum CGRP levels below the detection limit (<80 pmol/l) when CGRP-free serum was used for the standard curve. We defined the normal range for serum CGRP as below 100.8 pmol/l, which was the maximum level found in the healthy subjects. We studied serum levels of this peptide in patients with thyroid disease, because the thyroid may be one origin of circulating CGRP. Four of 10 patients with medullary thyroid carcinoma had elevated serum levels of CGRP. Seven of 24 patients with subacute thyroiditis had elevated serum levels of CGRP, but at least one year after clinical recovery, CGRP was undetectable in all. Seven of the 37 patients with hypothyroidism had elevated serum levels of CGRP. None of the patients with hyperthyroidism, adenomatous goiter, thyroid adenoma, or thyroid carcinoma had elevated serum CGRP levels. It is necessary to use a standard curve obtained by the addition of aprotinin and CGRP-free serum to the assay standards to measure serum CGRP levels. Some patients with subacute thyroiditis, hypothyroidism, or medullary thyroid carcinoma had elevated serum CGRP levels. (author)

  16. The Use of Chromothyrolymphography for Selection of Surgical Volume in Patients with Thyroid Cancer

    Directory of Open Access Journals (Sweden)

    A F Romanchishen

    2014-03-01

    Full Text Available Indirect chromothyrolymphography (ICTLG utilizes injection of the dye into the Thyroid (T in order to visu- alize intraorganic lymphatic network, and extra-T lymphatic vessels and regional lymph nodes, as well. In1980- ies we performed a study using either 2-3 ml of 1% Methylene blue in water or alcohol, or 0.4% solu- tion of indigo carmine, or 1% Brilliant green in alcohol to 197 patients. Comparative light microscopic study of 457 stained and unstained cervical lymph nodes was performed. An inexpensive and simple technique, indirect ICTLG gave us an evidence to solve a number of essential questions, such as whether to perform hemithyroidectomy in T1 carcinoma located in the middle of the T gland, or not; to follow the routs of the lymph flow, that are involved in metastasizing of T cancer; and to control parathyroid glands and the recur- rent nerve during resection of the T.

  17. Thyroid storm

    Science.gov (United States)

    Thyrotoxic storm; Hyperthyroid storm; Accelerated hyperthyroidism; Thyroid crisis; Thyrotoxicosis - thyroid storm ... Thyroid storm occurs due to a major stress such as trauma, heart attack , or infection. In rare ...

  18. Routine measurement of serum calcitonin in patients with nodular thyroid disorders?

    Energy Technology Data Exchange (ETDEWEB)

    Dietlein, M.; Schmidt, M.; Schicha, H. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Wieler, H. [Bundeswehrzentralkrankenhaus und Klinikum Kemperhof gGmbH, Koblenz (Germany). Abt. Nuklearmedizin; Schwab, R. [Bundeswehrzentralkrankenhaus, Koblenz (Germany). Abt. Allgemein-, Viszeral- und Thoraxchirurgie; Goretzki, P.E. [Staedtische Kliniken Neuss, Lukaskrankenhaus GmbH, Neuss (Germany). Chirurgische Klinik

    2008-07-01

    In spite of the fact that the German Society of Endocrinology has recommended calcitonin as screening-parameter the majority of physicians in Germany do not routinely use calcitonin in patients with thyroid nodules to exclude medullary thyroid cancer (MTC). The future revision of the recommendation should describe reference values for each commercially available assay, separately for men and women (basal and after pentagastrin-stimulation), and should define sonomorphological inclusion criteria. The epidemiological database of the prevalence of MTC is controversial and the specificity of basal elevated calcitonin levels is limited up to the 5-fold of the upper reference level. If renal insufficiency, bacterial infection, and an alcohol- or druginduced stimulation of calcitonin is excluded, hypercalcitoninaemia should be confirmed by a second measurement (if necessary using another assay). Stimulation of calcitonin by use of pentagastrin is mandatory prior to the decision on thyroidectomy. A stimulated calcitonin level < 100 pg/ml justifies 'wait and see'. If stimulated calcitonin levels range between 100 and 200 pg/ml or higher, the differentiation between C-cell hyperplasia and MTC remains uncertain, especially in men. The implementation of calcitonin- screening requires the definition of sonographic inclusion criteria and validation of each assay. Additional prerequisites are excellent logistic (short period between blood sampling and start of the laboratory test), knowledge of differential diagnoses, knowledge of the consumption of drugs and alcohol, availability of pentagastrin-testing and of moleculargenetic testing with full information to the patients and sufficient time before the decision on surgery is made. All this and the choice of a skilled surgeon, experienced in thyroidectomy and lymphadenectomy with a low rate of local complications are the rationale to recommend calcitonin-screening primarily in centers for thyroid disorders. (orig.)

  19. Routine measurement of serum calcitonin in patients with nodular thyroid disorders?

    International Nuclear Information System (INIS)

    Dietlein, M.; Schmidt, M.; Schicha, H.; Wieler, H.; Schwab, R.; Goretzki, P.E.

    2008-01-01

    In spite of the fact that the German Society of Endocrinology has recommended calcitonin as screening-parameter the majority of physicians in Germany do not routinely use calcitonin in patients with thyroid nodules to exclude medullary thyroid cancer (MTC). The future revision of the recommendation should describe reference values for each commercially available assay, separately for men and women (basal and after pentagastrin-stimulation), and should define sonomorphological inclusion criteria. The epidemiological database of the prevalence of MTC is controversial and the specificity of basal elevated calcitonin levels is limited up to the 5-fold of the upper reference level. If renal insufficiency, bacterial infection, and an alcohol- or druginduced stimulation of calcitonin is excluded, hypercalcitoninaemia should be confirmed by a second measurement (if necessary using another assay). Stimulation of calcitonin by use of pentagastrin is mandatory prior to the decision on thyroidectomy. A stimulated calcitonin level < 100 pg/ml justifies 'wait and see'. If stimulated calcitonin levels range between 100 and 200 pg/ml or higher, the differentiation between C-cell hyperplasia and MTC remains uncertain, especially in men. The implementation of calcitonin- screening requires the definition of sonographic inclusion criteria and validation of each assay. Additional prerequisites are excellent logistic (short period between blood sampling and start of the laboratory test), knowledge of differential diagnoses, knowledge of the consumption of drugs and alcohol, availability of pentagastrin-testing and of moleculargenetic testing with full information to the patients and sufficient time before the decision on surgery is made. All this and the choice of a skilled surgeon, experienced in thyroidectomy and lymphadenectomy with a low rate of local complications are the rationale to recommend calcitonin-screening primarily in centers for thyroid disorders. (orig.)

  20. Sarcoidosis and Thyroid Autoimmunity

    Directory of Open Access Journals (Sweden)

    Piera Fazzi

    2017-08-01

    Full Text Available Most of the studies have shown a higher risk for subclinical and clinical hypothyroidism, antithyroid autoantibodies [overall antithyroid peroxidase antibodies (TPOAb], and in general, thyroid autoimmunity, overall in the female gender in patients with sarcoidosis (S. A significantly higher prevalence of clinical hypothyroidism and Graves’ disease was also described in female S patients with respect to controls. Gallium-67 (Ga-67 scyntigraphy in S patients, in the case of thyroid uptake, suggests the presence of aggressive autoimmune thyroiditis and hypothyroidism. For this reason, ultrasonography and thyroid function should be done in the case of Ga-67 thyroid uptake. In conclusion, thyroid function, TPOAb measurement, and ultrasonography should be done to assess the clinical profile in female S patients, and the ones at high risk (female individuals, with TPOAb positivity, and hypoechoic and small thyroid should have periodically thyroid function evaluations and suitable treatments.

  1. The Combination of In vivo (124)I-PET and CT Small Animal Imaging for Evaluation of Thyroid Physiology and Dosimetry.

    Science.gov (United States)

    El-Ali, Henrik H; Eckerwall, Martin; Skovgaard, Dorthe; Larsson, Erik; Strand, Sven-Erik; Kjaer, Andreas

    2012-06-05

    A thyroid rat model combining functional and anatomical information would be of great benefit for better modeling of thyroid physiology and for absorbed dose calculations. Our aim was to show that (124)I-PET and CT small animal imaging are useful as a combined model for studying thyroid physiology and dose calculation. Seven rats were subjects for multiple thyroid (124)I-imaging and CT-scans. S-values [mGy/MBqs] for different thyroid sizes were simulated. A phantom with spheres was designed for validation of performances of the small animal PET and CT imaging systems. Small animal image-based measurements of the activity amount and the volumes of the spheres with a priori known volumes showed a good agreement with their corresponding actual volumes. The CT scans of the rats showed thyroid volumes from 34-70 mL. The wide span in volumes of thyroid glands indicates the importance of using an accurate volume-measuring technique such as the small animal CT. The small animal PET system was on the other hand able to accurately estimate the activity concentration in the thyroid volumes. We conclude that the combination of the PET and CT image information is essential for quantitative thyroid imaging and accurate thyroid absorbed dose calculation.

  2. The Combination of In vivo 124I-PET and CT Small Animal Imaging for Evaluation of Thyroid Physiology and Dosimetry

    Directory of Open Access Journals (Sweden)

    Henrik H. El-Ali

    2012-06-01

    Full Text Available Objective: A thyroid rat model combining functional and anatomical information would be of great benefit for better modeling of thyroid physiology and for absorbed dose calculations. Our aim was to show that 124I-PET and CT small animal imaging are useful as a combined model for studying thyroid physiology and dose calculation. Methods: Seven rats were subjects for multiple thyroid 124I-imaging and CT-scans. S-values [mGy/MBqs] for different thyroid sizes were simulated. A phantom with spheres was designed for validation of performances of the small animal PET and CT imaging systems. Results: Small animal image-based measurements of the activity amount and the volumes of the spheres with a priori known volumes showed a good agreement with their corresponding actual volumes. The CT scans of the rats showed thyroid volumes from 34–70 mL. Conclusions: The wide span in volumes of thyroid glands indicates the importance of using an accurate volume-measuring technique such as the small animal CT. The small animal PET system was on the other hand able to accurately estimate the activity concentration in the thyroid volumes. We conclude that the combination of the PET and CT image information is essential for quantitative thyroid imaging and accurate thyroid absorbed dose calculation.

  3. A buoyancy technique for measuring plant volumes | NG | African ...

    African Journals Online (AJOL)

    All techniques of measuring plant volumes that are described in the literature measure the volume of a liquid that is displaced by the immersion of the plant material. The "buoyancy" technique is based on the principle of Archimedes and is an improvement on displacement methods in that it is sensitive to very small volumes, ...

  4. Accuracy of Prader orchidometer in measuring testicular volume ...

    African Journals Online (AJOL)

    Objective: To determine the accuracy of Prader orchidometer for measuring the testicular volume by comparing the resultant measurement with the actual testicular volume in humans. Materials and Methods: The testicular volumes of 121 testes from 62 patients with prostate cancer (mean age 72.74 ± 9.38 years) were ...

  5. Ultrasound measurements of testicular volume: Comparing the three ...

    African Journals Online (AJOL)

    Objective: To determine the accuracy of various ultrasound formulas for measuring the testicular volume in humans by comparing the resultant measurements with the actual testicular volume. Subjects and methods: The testicular volume of 121 testes from 62 patients with prostate cancer (mean age 72.7 ± 9.4) was ...

  6. Thyroid Problems

    Science.gov (United States)

    ... What is the thyroid gland and what are thyroid disorders? Your thyroid gland is a small structure in ... get older, you’re more likely to develop thyroid disorders. In addition to being more common with age, ...

  7. Postpartum Thyroiditis

    Science.gov (United States)

    ... disorders cannot be distinguished from one another on pathology specimens. As in Hashimoto’s thyroiditis, postpartum thyroiditis is associated with the development of anti-thyroid (anti-thyroid peroxidase, anti- thyroglobulin) antibodies. Women with ...

  8. IAEA intercomparison exercises of thyroid measurement: performance of Latin American and Caribbean laboratories

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Cruz-Suarez, R.

    2016-01-01

    131 I is widely used in Latin America and Caribbean Region in the field of nuclear medicine and has been recognised as one of the main sources of potential intake of radionuclides by the staff. The In Vivo Monitoring laboratory of the Institute for Radiation Protection and Dosimetry (IRD-CNEN-Brazil) organised three intercomparison exercises (2005, 2009 and 2013) in the scope of IAEA technical cooperation projects RLA9049 and RLA9066 aimed to disseminate and harmonise the technique for measuring 131 I in the human thyroid. The number of participants in Latin America increased from 9 to 20 institutions from 7 and 13 countries, respectively, over the last 10 y. The participants have improved significantly their ability on the in vivo measurement technique. In the 2013 round all laboratories which reported results presented performances in an acceptable range according to the ISO criteria indicating the benefit of such exercises in the region. (authors)

  9. Measurement of synovial fluid volume using urea.

    Science.gov (United States)

    Kraus, V B; Stabler, T V; Kong, S Y; Varju, G; McDaniel, G

    2007-10-01

    To examine the utility of using urea concentrations for determining Synovial Fluid (SF) joint volume in effused and non-effused joints. Knee joint SF was aspirated from 159 human study participants with symptomatic osteoarthritis of at least one knee either directly (165 knees) or by lavage (110 knees). Serum was obtained immediately prior to SF aspiration. Participants were asked to rate individual knee pain, aching or stiffness. SF and serum urea levels were determined using a specific enzymatic method run on an automated CMA600 analyzer. Cell counts were performed on direct SF aspirates when volume permitted. The formula for calculating SF joint volume was as follows: V(j)=C(D)(V(I))/(C-C(D)) with V(j)=volume of SF in entire joint, C(D)=concentration of urea in diluted (lavage) SF, V(I)=volume of saline injected into joint, and C=concentration of urea in undiluted (neat) SF derived below where C=0.897(C(S)) and C(s)=concentration of urea in serum. There was an excellent correlation (r(2)=0.8588) between SF and serum urea in the direct aspirates with a ratio of 0.897 (SF/serum). Neither urea levels nor the SF/serum ratio showed any correlation with Kellgren Lawrence (KL) grade, or cell count. While urea levels increased with age there was no change in the ratio. Intraarticular SF volumes calculated for the lavaged knees ranged from 0.555 to 71.71ml with a median volume of 3.048ml. There was no correlation of SF volume to KL grade but there was a positive correlation (P=0.001) between SF volume and self-reported individual knee pain. Our urea results for direct aspirates indicate an equilibrium state between serum and SF with regard to the water fraction. This equilibrium exists regardless of disease status (KL grade), inflammation (cell count), or age, making it possible to calculate intraarticular volume of lavaged joints based upon this urea method. Most of the joint volumes we calculated fell within the previously reported range for normal knees of 0.5-4.0ml

  10. Brain volume measurement using three-dimensional magnetic resonance images

    International Nuclear Information System (INIS)

    Ishimaru, Yoshihiro

    1996-01-01

    This study was designed to validate accurate measurement method of human brain volume using three dimensional (3D) MRI data on a workstation, and to establish optimal correcting method of human brain volume on diagnosis of brain atrophy. 3D MRI data were acquired by fast SPGR sequence using 1.5 T MR imager. 3D MRI data were segmented by region growing method and 3D image was displayed by surface rendering method on the workstation. Brain volume was measured by the volume measurement function of the workstation. In order to validate the accurate measurement method, phantoms and a specimen of human brain were examined. Phantom volume was measured by changing the lower level of threshold value. At the appropriate threshold value, percentage of error of phantoms and the specimen were within 0.6% and 0.08%, respectively. To establish the optimal correcting method, 130 normal volunteers were examined. Brain volumes corrected with height weight, body surface area, and alternative skull volume were evaluated. Brain volume index, which is defined as dividing brain volume by alternative skull volume, had the best correlation with age (r=0.624, p<0.05). No gender differences was observed in brain volume index in contrast to in brain volume. The clinical usefulness of this correcting method for brain atrophy diagnosis was evaluated in 85 patients. Diagnosis by 2D spin echo MR images was compared with brain volume index. Diagnosis of brain atrophy by 2D MR image was concordant with the evaluation by brain volume index. These results indicated that this measurement method had high accuracy, and it was important to set the appropriate threshold value. Brain volume index was the appropriate indication for evaluation of human brain volume, and was considered to be useful for the diagnosis of brain atrophy. (author)

  11. Thyroglobulin measurement using highly sensitive assays in patients with differentiated thyroid cancer:

    DEFF Research Database (Denmark)

    Giovanella, Luca; Clark, Penelope M; Chiovato, Luca

    2014-01-01

    Differentiated thyroid cancer (DTC) is the most common endocrine cancer and its incidence has increased in recent decades. Initial treatment usually consists of total thyroidectomy followed by ablation of thyroid remnants by iodine-131. As thyroid cells are assumed to be the only source...... at low concentrations now allows detection of very low Tg concentrations reflecting minimal amounts of thyroid tissue without the need for TSH stimulation. Use of these highly sensitive Tg assays has not yet been incorporated into clinical guidelines but they will, we believe, be used by physicians...

  12. Pulmonary blood volume measured by RI angiocardiography

    International Nuclear Information System (INIS)

    Ono, Kazuo

    1982-01-01

    RI angiocardiography (RACG) was performed in 81 patients with heart disease without congestive heart failure at the time, and the results were compared between the groups with mitral valve disease and other diseases. Cardiac output (CO) and pulmonary mean transit time (PMTT) were compared with the results from the dye dilution method in the same patients. PMTT directly measured by RACG was also compared with the peak to peak time (P-PT). P-PT was expressed as the distance from the right to the left peak time in radiocardiography (RCG). There were good correlations between the CO and PMTT obtained from the RI method and those of the dye dilution method (r = 0.90, r = 0.84). The ralationship between PMTT and P-PT in mitral valve disease was different from that of other diseases. The average value of PMTT was 5.2 +- 1.0 seconds, and pulmonary blood volume (PBV) was 315 +- 57 ml/m 2 in the control group. The PBV values were markedly increased in patients with mitral stenosis (558 +- 132 ml/m 2 ) and mitral regurgitation (444 +- 119 ml/m 2 ), and were slightly increased in aortic valve disease, congenital shunt disease and cardiomyopathy. The patients with ischemic heart disease had normal PBV. In mitral valve disease, the direct method using PMTT of RACG is more accurate than the presumption method using P-PT of RCG. The determination of PBV by this method is very important to observe hemodynamic states in mitral valve disease. (J.P.N.)

  13. Results of the argentinian intercomparison on internal dosimetry 2014. Measurement of thyroid burden

    International Nuclear Information System (INIS)

    Rojo, A.M.; Puerta, N.; Gossio, S.; Gómez Parada, I.

    2015-01-01

    Internal dosimetry intercomparisons are essential for the verification of the capability to perform direct measurements of “1”3”1I thyroid burden and the expertise in the interpretation of these data for dose assessment. To that aim, in 2014 the National Intercomparison Exercise was organized and coordinated by the Internal Dosimetry Laboratory of the Autoridad Regulatoria Nuclear (ARN) of Argentina. The exercise counted with the participation of six internal dosimetry services: nuclear power plants (NA-SA CNA and NA-SA CNE), CNEA Atomic Centres: Bariloche (CAB) and Ezeiza (CAE), Roffo Institute (UBA – CNEA) and ARN. This report shows a complete analysis of the participant’s results in this exercise. (authors) [es

  14. Effect of lithium on thyroid function in adolescents with mood disorder.

    Science.gov (United States)

    Sethy, Rati Ranjan; Sinha, Vinod Kumar

    2016-12-01

    The purpose of the study was to determine thyroid gland volume and the frequency of thyroid dysfunction by using ultrasonography and laboratory parameters (TSH, T3, and T4) in long term lithium treated adolescent patients with mood disorder. In a cross-sectional study, we performed ultrasonography and thyroid function test in 30 adolescent patients on long-term lithium treatment for mood disorder. Patients with adequate serum lithium levels for one year or more were taken for the study. Ultrasonography examinations of thyroid gland and thyroid function test were performed in these patients. Patients who were on other mood stabilizers were taken up as controls. The thyroid stimulating hormone (TSH) levels and ultrasonographically measured thyroid volume were significantly higher in patients receiving lithium in comparison to patients with other mood stabilizers. A significant positive correlation was found between total thyroid volume and TSH levels. Adolescent mood disorder patients on long term lithium therapy have increased thyroid volume and isolated increases in serum TSH levels compared to those on other mood stabilizers. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Measurement of the iodine uptake by the thyroid: comparative analysis between the gamma camera system with 'pinhole' collimator and 13S002 system

    International Nuclear Information System (INIS)

    Silva, Carlos Borges da; Mello, Rossana Corbo R. de; Rebelo, Ana Maria O.

    2002-01-01

    The thyroid uptake measurements are common in medical uses and are considered a direct and precise form of diagnostic, however, different results have been observed as measurements of thyroid uptake are taken using distinct equipment. This study attempts to find the cause of the differences between a thyroid uptake probe and a gamma camera. These discrepancies can be associated to the different patients samples, equipment's problems or operator procedures errors. This work presents the results of comparative uptake measurements performed in a neck phantom and a 4-hour thyroid uptake study in 40 patients, using a Gamma Camera Ohio Nuclear model Sigma 410 with a pinhole collimator and Nuclear Medicine System model 13S002, developed by Instituto de Engenharia Nuclear. The results observed show that in spite of non satisfactory results commented in literature, both the System 13S002 and System Gamma Camera Ohio can be used in uptake thyroid diagnostic with statistical confidence degree of 99 %. (author)

  16. Assessment of salivary gland dysfunction after radioiodine therapy for thyroid carcinoma using non-contrast-enhanced CT: the significance of changes in volume and attenuation of the glands.

    Science.gov (United States)

    Nabaa, B; Takahashi, K; Sasaki, T; Okizaki, A; Aburano, T

    2012-11-01

    Although radiation induced damage to the salivary gland is a known complication of radioactive iodine ((131)I) therapy for thyroid carcinoma, prediction of the severity and reversibility of sialoadenitis is difficult. Our aim was to correlate the extent of salivary dysfunction assessed by salivary gland scintigraphy with changes in the volume and attenuation of salivary glands on nonenhanced CT in postoperative patients with thyroid cancer treated with RIT. Forty patients with thyroid carcinoma, 13 men (age range, 21-80 years) and 27 women (age range, 28-75 years) who underwent a total thyroidectomy and were treated with RIT were assessed retrospectively. On CT, the percentage of volume reduction and the difference in attenuation of the parotid and submandibular glands after RIT were determined and correlated with the extent of radiation-induced salivary dysfunction on scintigraphy. The salivary gland volume significantly decreased with an increase in the dysfunction grade on scintigraphy for both the parotid and submandibular glands (P gland (P gland. The cutoff value of volume reduction to diagnose severe gland dysfunction was 19.5% (sensitivity, 86.0%; specificity, 100%) for the parotid gland and 31.0% (sensitivity, 100%; specificity, 97.0%) for the submandibular gland, and that of the attenuation change was 9.8 HU (sensitivity, 81.0%; specificity, 95%) for the parotid gland. The reduction in volume of the parotid and submandibular glands and the increase in attenuation of the parotid gland on nonenhanced CT can be indicators of the grade of RIT-induced salivary dysfunction.

  17. RESIDUAL LIMB VOLUME CHANGE: SYSTEMATIC REVIEW OF MEASUREMENT AND MANAGEMENT

    Science.gov (United States)

    Sanders, JE; Fatone, S

    2014-01-01

    Management of residual limb volume affects decisions regarding timing of fit of the first prosthesis, when a new prosthetic socket is needed, design of a prosthetic socket, and prescription of accommodation strategies for daily volume fluctuations. The purpose of this systematic review was to assess what is known about measurement and management of residual limb volume change in persons with lower-limb amputation. Publications that met inclusion criteria were grouped into three categories: (I) descriptions of residual limb volume measurement techniques; (II) studies on people with lower-limb amputation investigating the effect of residual limb volume change on clinical care; and (III) studies of residual limb volume management techniques or descriptions of techniques for accommodating or controlling residual limb volume. The review showed that many techniques for the measurement of residual limb volume have been described but clinical use is limited largely because current techniques lack adequate resolution and in-socket measurement capability. Overall, there is limited evidence regarding the management of residual limb volume, and the evidence available focuses primarily on adults with trans-tibial amputation in the early post-operative phase. While we can draw some insights from the available research about residual limb volume measurement and management, further research is required. PMID:22068373

  18. Measurement of liver volume by emission computed tomography

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.

    1979-01-01

    In 22 volunteers without clinical or laboratory evidence of liver disease, liver volume was determined using single-photon emission computed tomography (ECT). This technique provided excellent object contrast between the liver and its surroundings and permitted calculation of liver volume without geometric assumptions about the liver's configuration. Reproducibility of results was satisfactory, with a root-mean-square error of less than 6% between duplicate measurements in 15 individuals. The volume measurements were validated by the use of phantoms

  19. A structural abnormality associated with graded levels of thyroid hormone insufficiency: Dose dependent increases in heterotopia volume

    Science.gov (United States)

    A large number of environmental contaminants reduce circulating levels of thyroid hormone (TH), but clear markers of neurological insult associated with modest TH insufficiency are lacking. We have previously identified the presence of an abnormal cluster of misplaced neurons in ...

  20. Measurement of thyroids indicators in nearest areas to the Chernobyl accident

    International Nuclear Information System (INIS)

    Garcia L, O.; Valdes R, M.; Cardenas H, J.

    1996-01-01

    The levels of T4 hormone and the frequency of thyroid enlargement were evaluated in five groups formed with 3033 children from 421 locations with different levels of Cs-137 surface contamination. The only difference among groups is the increase of the thyroid enlargement frequency from less contaminated locations to more contaminated at the time of the accident. Other significant findings in studied cases were: high levels of T4 (18%), normal levels of TSH (99.3%), thyroid enlargement (61%, around 90% of which are 1A or 1B grade). (authors). 3 refs., 6 tabs

  1. Indirect thyroid lymphography in the thyroid diseases diagnosis

    International Nuclear Information System (INIS)

    Kradinov, A.I.; Fesenko, V.P.; Kabalich, A.K.

    1981-01-01

    Indirect thyroid lymphography with water-soluble radiographic agents has been applied. This method allows contrast lymph microvessels of the thyroid gland, providing the detection of volume formations of 0.3 to 0.4 cm and more in diameter. 232 patients with different thyroid diseases were examined. Different rate of the water-soluble contrast agent resolution in diffuse toxic and nodular goiter, thyroid cancer, chronic thyroiditis is of great importance in differential diagnosis of these diseases. This method provides necessary information on the organs inner structure, its topography and size [ru

  2. Thyroid ultrasound

    Science.gov (United States)

    ... Thyroid physiology and diagnostic evaluation of patients with thyroid disorders. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: Elsevier; 2016:chap 11. ... Thyroid Tests Read more Ultrasound ...

  3. Monitoring intervals for measurement of the radionuclides 125 I and 129I in thyroid glands

    International Nuclear Information System (INIS)

    Simanca, Yoan Yera; Bejerano, Gladys M. Lopez

    2013-01-01

    This work shows the monitoring interval, which can be implemented in the Laboratorio de Contaminacion Interna del Centro de Proteccion e Higiene de las Radiaciones, for direct measurement in the thyroid gland of radionuclides 125 I and 129 I . Were used two measuring systems, one employing a scintillating detector and the other detector Phoswich. Both detectors were placed inside a depth camera, 2.5 x 2.5 x 2.5m of dimension covered with 15 cm of steel, 3 mm lead, 1.8 mm tin and 1.5 mm of copper. Was calculated for each system, the minimum detectable activity, and based on this, the monitoring interval is determined. Was obtained, for 125 , all tested intervals, 120, 90,60,30 , 14, and 7 days may be implemented with both systems. In the case of the radionuclide 129 I, with the installation of scintillating detector can only be implemented the intervals 120, 90, and 60 days , and for installation with Phoswich, all evaluated

  4. Measurement of radiation exposure in attendants of thyroid cancer patients treated with 131I

    International Nuclear Information System (INIS)

    Ramirez G, Y. T.

    2012-01-01

    Patients treated with 131 I for differentiated thyroid cancer present radiological risk to relatives, occupational exposed workers and general public. Recently, the IAEA issued document K-9010241, 2010, which recommends that patient discharge from hospital must be based on the particular status of each patient, unlike the current criteria applied in Mexico based on the exposure rate at a 1 m distance. In this work thermoluminescent dosimeters were used during a 15 day period to measure the effective dose received by 40 family caregivers of patients treated with 131 I, after their release from hospital 'Instituto Nacional de Cancerologia', Mexico. Relatives were classified in two groups, ambulatory (outpatients) and hospitalized (inpatients), according to the release mode of the patient. Measurements were performed for 20 family caregivers in each group. The effective dose received by all family members of outpatient and inpatient groups was found to be smaller that 5 mSv. In addition, 70 and 90% of inpatient and outpatient groups, respectively, received doses lower than 1 mSv. These data provide information which allow to give recommendations of possible modifications to current regulations in Mexico regarding discharge from hospital of patients treated with radiopharmaceuticals. (Author)

  5. Comparison between two calibration models of a measurement system for thyroid monitoring

    International Nuclear Information System (INIS)

    Venturini, Luzia

    2005-01-01

    This paper shows a comparison between two theoretical calibration that use two mathematical models to represent the neck region. In the first model thyroid is considered to be just a region limited by two concentric cylinders whose dimensions are those of trachea and neck. The second model uses functional functions to get a better representation of the thyroid geometry. Efficiency values are obtained using Monte Carlo simulation. (author)

  6. High-speed volume measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Michael H.; Doyle, Jr., James L.; Brinkman, Michael J.

    2018-01-30

    Disclosed is a volume sensor having a first axis, a second axis, and a third axis, each axis including a laser source configured to emit a beam; a parallel beam generating assembly configured to receive the beam and split the beam into a first parallel beam and a second parallel beam, a beam-collimating assembly configured to receive the first parallel beam and the second parallel beam and output a first beam sheet and a second beam sheet, the first beam sheet and the second beam sheet being configured to traverse the object aperture; a first collecting lens and a second collecting lens; and a first photodetector and a second photodetector, the first photodetector and the second photodetector configured to output an electrical signal proportional to the object; wherein the first axis, the second axis, and the third axis are arranged at an angular offset with respect to each other.

  7. Chapter 3. Thyroid

    International Nuclear Information System (INIS)

    Tubiana, M.; Perez, R.

    1975-01-01

    In the context of a functional thyroid exploration study the physiopathology of the thyroid was reviewed on the basis of data supplied by the use of radioisotopes, especially radioiodine. It was pointed out in this respect that the functional activity of the thyroid is closely bound up with the iodine metabolism. The different stages of the iodine metabolism were therefore described in relation to the methods used for their exploration: study of iodine intake to the thyroid and uptake measurement; hormonogenesis and secretion of hormone iodine; transport and circulation of thyroid hormones; exploration of the hypothalamus-pituitary gland-thyroid axis. It was pointed out in addition that the morphological examination often complements the thyroid function exploration and is carried out whenever thyroid palpation reveals an anomaly. Data obtained by scintigraphy are given in this repect. Furthermore the remarkable capacity of hyperthyroid tissues to concentrate radioactive iodine may be used therapeutically to perform an endogenous irradiation of the thyroid. The treatment of both hyperthyroidism and thyroid cancers with radioactive iodine was studied [fr

  8. Volume measurement study for large scale input accountancy tank

    International Nuclear Information System (INIS)

    Uchikoshi, Seiji; Watanabe, Yuichi; Tsujino, Takeshi

    1999-01-01

    Large Scale Tank Calibration (LASTAC) facility, including an experimental tank which has the same volume and structure as the input accountancy tank of Rokkasho Reprocessing Plant (RRP) was constructed in Nuclear Material Control Center of Japan. Demonstration experiments have been carried out to evaluate a precision of solution volume measurement and to establish the procedure of highly accurate pressure measurement for a large scale tank with dip-tube bubbler probe system to be applied to the input accountancy tank of RRP. Solution volume in a tank is determined from substitution the solution level for the calibration function obtained in advance, which express a relation between the solution level and its volume in the tank. Therefore, precise solution volume measurement needs a precise calibration function that is determined carefully. The LASTAC calibration experiments using pure water showed good result in reproducibility. (J.P.N.)

  9. Measurement variability error for estimates of volume change

    Science.gov (United States)

    James A. Westfall; Paul L. Patterson

    2007-01-01

    Using quality assurance data, measurement variability distributions were developed for attributes that affect tree volume prediction. Random deviations from the measurement variability distributions were applied to 19381 remeasured sample trees in Maine. The additional error due to measurement variation and measurement bias was estimated via a simulation study for...

  10. Serial measurements of serum free thyroid hormones in patients with septic and traumatic shock

    International Nuclear Information System (INIS)

    Mahlstedt, J.; Hotze, A.; Pasch, T.; Buheitel, G.; Pscheidl, E.

    1985-01-01

    A study in intensive care unit patients was undertaken for analyzing the changes of thyroid function parameters during shock. From a total of 36 patients 16 septic patients were classified into two groups of different severity by use of a sepsis score, and the same was done in 20 posttraumatic patients resulting in three groups by use of a traumatic score. TSH-levels showed a clear relation to the sepsis score during follow-up with very low TSH in severe shock and increase during relief. T 3 -parameters (TT 3 , FT 3 , T 3 /TBG, T 3 xT 3 RU) show a strong relation to TSH-changes generally being decreased outside of the normal range. T 4 -parameters (TT 4 , FT 4 , T 4 /TBG, T 4 xT 3 RU) are not as clearly related to TSH-changes, they are in the normal ranges except FT 4 , which is slightly decreased in severe shock. Therefore, in shock patients FT 3 and FT 4 measured by the analogue tracer principle do not provide different information compared to the respective indices of free hormone concentrations. Slight differences in relation to the respective normal ranges could raise misclassification problems for FT 4 (false hypothyroid), however, this deviation will not be a cause to overlook hyperthyroidism in NTI as shown up by a clinical case. (orig.)

  11. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  12. A longitudinal study on the radiation-induced thyroid gland changes after external beam radiotherapy of nasopharyngeal carcinoma.

    Science.gov (United States)

    Lin, Zhixiong; Wu, Vincent Wing-Cheung; Lin, Jing; Feng, Huiting; Chen, Longhua

    2011-01-01

    Radiation-induced thyroid disorders have been reported in radiotherapy of head and neck cancers. This study evaluated the radiation-induced damages to thyroid gland in patients with nasopharyngeal carcinoma (NPC). Forty-five patients with NPC treated by radiotherapy underwent baseline thyroid hormones (free triiodothyronine, free thyroxine [fT4], and thyrotropin [TSH]) examination and CT scan before radiotherapy. The volume of the thyroid gland was calculated by delineating the structure in the corresponding CT slices using the radiotherapy treatment planning system. The thyroid doses were estimated using the treatment planning system. Subsequent CT scans were conducted at 6, 12, and 18 months after radiotherapy, whereas the hormone levels were assessed at 3, 6, 12, and 18 months after radiotherapy. Trend lines of the volume and hormone level changes against time were plotted. The relationship between the dose and the change of thyroid volume and hormone levels were evaluated using the Pearson correlation test. An average of 20% thyroid volume reduction in the first 6 months and a further 8% shrinkage at 12 months after radiotherapy were observed. The volume reduction was dependent on the mean thyroid doses at 6, 12, and 18 months after radiotherapy (r = -0.399, -0.472, and -0.417, respectively). Serum free triiodothyronine and fT4 levels showed mild changes of thyroid doses between patients with hypothyroidism and normal thyroid function. Radiotherapy for patients with NPC caused radiation-induced changes of the thyroid gland. The shrinkage of the gland was greatest in the first 6 months after radiotherapy, whereas the serum fT4 and TSH levels changed at 12 months. Radiation-induced changes were dependent on the mean dose to the gland. Therefore, measures to reduce the thyroid dose in radiotherapy should be considered.

  13. A simple photogrammetric method of measuring anterior chamber volume.

    Science.gov (United States)

    Johnson, S B; Coakes, R L; Brubaker, R F

    1978-04-01

    We devised a convenient method of measuring anterior chamber volume in man. Photographs of the anterior chamber were taken with a Zeiss photographic slit lamp with a Polaroid attachment, and measured with a specially constructed transparent scale. Using this method, the standard deviation of individual measurements of volume on different occasions in a given eye was 8 microliter. The standard deviation of the differences between right and left eyes of normal subjects was 10 microliter. The volume of the anterior chamber measured in 78 eyes of 39 normal subjects (mean age, 28 years; range, 19 to 56 years) was found to be 209 +/- 37 microliter (mean +/- SD). We observed a small negative correlation between the age of the subject and the volume of the anterior chamber.

  14. Evaluation of signal intensity of various thyroid tissues on MR imaging

    International Nuclear Information System (INIS)

    Baba, Koichiro; Imanishi, Yoshimasa; Igarashi, Ryuukou; Shinagawa, Toshihito

    2001-01-01

    Although normal thyroid mainly consists of thyroid follicles and has large amount of water in them, it shows low signal intensity on T2 weighted MR image. In this paper, we analysed the signal intensity of the thyroid in clinical cases and investigated the relationship between signal intensity and iodine concentration. In forty-one patients who have clinically suspected thyroid diseases, fifty-three MRI examinations of the neck and forty-three thyroid CT examinations were performed. The MR imaging of the neck was performed with T1 weighted image, T2 weighted image, and STIR image. Iodine concentration of the thyroid was measured by the CT software which was originally made by one of the authors (Y.I.). The signal intensity on T2 weighted image negatively correlated with iodine concentration, although there was no relationship between iodine concentration and its signal intensity on T1 weighted image. On T2 weighted image, the intensity of thyroid with high iodine concentration showed a low signal and that of thyroid with low iodine concentration presented a high signal. The thyroid with chronic thyroiditis showed higher signal intensity than normal thyroid and adenmatous goiter on T2 weighted image and STIR image. On T2 weighted image and STIR image, the signal intensity of any thyroid nodules were higher than that of normal thyroid. In addition, follicular adenoma and partially malignant nodules showed a higher signal intensity than thyroid carcinomas. According to previous reports, decreased iodine concentration in thyroid follicles represents decreased concentration of iodine-binding proteins in follicles as well as decreased volume of follicular content in the thyroid. On MR imaging, very high concentration of protein in water solution does not only cause shortening of T1 relaxation time but also shortening of T2 relaxation time resulting in low signal intensity. In the present study, our data seem to suggest that very high concentration of iodine

  15. Measurements for reduction and prevention of radioiodine uptake by the thyroid

    International Nuclear Information System (INIS)

    Boerner, W.; Becker, W.

    1987-01-01

    After incorporation of radioiodine the thyroid gland is the organ with the highest radiation exposure. The most important methods for reduction or prevention of radioiodine incorporation by inhalation, ingestion or cutaneous resorption are the prevention of contamination and incorporation. The protection against external radiation and the prophylaxis with iodine are also very useful. The maximum of radioiodine exposure is reached within the first few days after exposure due to the short physical half-life of I-131. In addition to non-specific methods of protection for contamination and incorporation, thyroid blockage by iodine is of major importance. With 100 mg potassium iodide, taken in intervalls of eight hours, the radioiodine uptake of the thyroid gland can be reduced to 1%, provided that administration takes place before, or simultaneously with the exposure. The most important side effect, especially in endemic goiter areas, is the induction of thyrotoxicosis. In newborns and infants myxedema and the induction of an iodide-goiter may occur. Alternatively to iodide prophylaxis, the competitive restriction of the radioiodine uptake into the thyroid gland may be achieved using perchlorate. However, perchlorate shall not be preferred to iodide because of its potential side-effects. High doses of iodide should only be given, if the calculated thyroid radiation exposure is more than 0.25 Sv, because only at this dose level benefit is higher than risk. (orig.) [de

  16. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    International Nuclear Information System (INIS)

    Muessig, K.; Leibniz Center for Diabetes Research, Duesseldorf; University Hospital of Tuebingen; Schraml, C.; Schwenzer, N.F.; University Hospital of Tuebingen; Rietig, R.; Balletshofer, B.; Martirosian, P.; Haering, H.U.; Schick, F.; Claussen, C.D.

    2012-01-01

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  17. Thyroid perfusion imaging as a diagnostic tool in Graves' disease. Arterial spin labeling magnetic resonance imaging vs. colour-coded Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Muessig, K. [University Hospital of Duesseldorf (Germany). Dept. of Metabolic Diseases; Leibniz Center for Diabetes Research, Duesseldorf (Germany). Inst. for Clinical Diabetology; University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Schraml, C.; Schwenzer, N.F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology; Rietig, R.; Balletshofer, B. [University Hospital of Tuebingen (Germany). Div. of Endocrinology, Diabetes, Nephrology, Angiology, and Clinical Chemistry; Martirosian, P.; Haering, H.U.; Schick, F. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Section on Experimental Radiology; Claussen, C.D. [University Hospital of Tuebingen (Germany). Dept. of Radiology, Diagnostic and Interventional Radiology

    2012-12-15

    Purpose: Though increased thyroid perfusion assessed by colour-coded Doppler ultrasound (CDUS) is characteristic of Graves' disease (GD), sometimes perfusion assessment by CDUS is not possible. In these cases, arterial spin labelling (ASL), a novel magnetic resonance imaging (MRI) technique allowing non-invasive thyroid perfusion quantification, may have additional diagnostic value. We aimed to evaluate the potential of ASL-MRI for assessment of increased blood perfusion in patients with GD compared to CDUS. Materials and Methods: Thyroid perfusion was measured by CDUS (volume flow rate calculated from pulsed wave Doppler signals and vessel diameter) and ASL-MRI at 1.5 T in 7 patients with GD and 10 healthy controls. Results: In patients with GD, average perfusion in both thyroid lobes was markedly increased compared to controls. Both techniques applied for volume related perfusion as well as absolute volume flow in thyroid feeding vessels provided similar results (all p = 0.0008). Using a cut-off value of 22 ml/min for the volume flow rate assessed by CDUS in the four feeding vessels allowed discrimination between patients with GD and controls in all cases. After adjusting thyroid perfusion for the differences in organ volume, both CDUS and ASL revealed also complete discrimination between health and disease. Conclusion: Thyroid perfusion measurement by ASL-MRI reliably discriminate GD from normal thyroid glands. In patients in whom thyroid arteries cannot be depicted by CDUS for technical or anatomical reasons, ASL-MRI may have additional diagnostic value. (orig.)

  18. Thyroid Nodules

    Science.gov (United States)

    Thyroid nodules Overview Thyroid nodules are solid or fluid-filled lumps that form within your thyroid, a small gland located at the base of ... just above your breastbone. The great majority of thyroid nodules aren't serious and don't cause ...

  19. Characteristics of bulk goods volume flow measurement on conveyors

    Directory of Open Access Journals (Sweden)

    Aleksandrović Snežana S.

    2015-01-01

    Full Text Available Volume flow measuring system is indirect method of conveyor belt bulk material mass flow determining. This paper deals with on-line measurement of the flow of material by using the optic and ultrasonic flow measuring devices. The advantages and disadvantages of the described methods are presented as well as the necessity of the application of high accuracy flowmeters.

  20. Measurement of the thyroid's iodine absorption utilizing minimal /sup 131/I dose

    Energy Technology Data Exchange (ETDEWEB)

    Paz A, B.; Villegas A, J.; Delgado B, C. (Universidad Nacional San Agustin de Arequipa (Peru). Departamento de Bioquimica)

    1981-03-01

    We utilize a minimal dose of /sup 131/I thus limiting the contact of the thyroid tissues with the isotopic materials to determine the absorption of /sup 131/I by the thyroid from 6 to 24 hours in 90 pupils of the locality of Arequipa. The average rate of absorption in 6 and 24 hours in the case considered are of 24.15% and 35.42% respectively, with a standard deviation of 6.93% and 9.61%. No significant differences were reported from the results of those of adults and our own results in all the probes which were undertaken.

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... may be performed to measure the level of thyroid hormones in your blood. You may be told not to eat for several hours before your exam because eating can affect the ... as well. Thyroid Scan You will be positioned on an examination ...

  2. Accurate volume measurement system for plutonium nitrate solution

    Energy Technology Data Exchange (ETDEWEB)

    Hosoma, Takashi; Maruishi, Yoshihiro (Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works); Aritomi, Masanori; Kawa, Tunemichi

    1993-05-01

    An accurate volume measurement system for a large amount of plutonium nitrate solution stored in a reprocessing or a conversion plant has been developed at the Plutonium Conversion Development Facility (PCDF) in the Power Reactor and Nuclear Fuel Development Corp. (PNC) Tokai Works. A pair of differential digital quartz pressure transducers is utilized in the volume measurement system. To obtain high accuracy, it is important that the non-linearity of the transducer is minimized within the measurement range, the zero point is stabilized, and the damping property of the pneumatic line is designed to minimize pressure oscillation. The accuracy of the pressure measurement can always be within 2Pa with re-calibration once a year. In the PCDF, the overall uncertainty of the volume measurement has been evaluated to be within 0.2 %. This system has been successfully applied to the Japanese government's and IAEA's routine inspection since 1984. (author).

  3. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  4. Effects of amiodarone therapy on thyroid iodine content as measured by x-ray fluorescence

    International Nuclear Information System (INIS)

    Fragu, P.; Schlumberger, M.; Davy, J.M.; Slama, M.; Berdeaux, A.

    1988-01-01

    Thyroid iodine content (TIC) was measured by x-ray fluorescence in 68 patients who had received amiodarone treatment for varying intervals (1 g/week for 1-120 months). Thirty-six patients were euthyroid; the mean TIC of the patients (n = 15), who had been treated for less than 12 months was 30 +/- 19 (+/- SD) mg, twice the normal mean value (14.6 +/- 5.0 mg), and it was 39 +/- 17 mg in those (n = 16) who had been treated for 12-60 months and 29 +/- 6 mg in those (n = 5) who had been treated longer (greater than 60 months). Nineteen patients were hyperthyroid and had elevated TIC values. Of them, 6 patients had a goiter; their TIC (50 +/- 19 mg) was not significantly different from that of the hyperthyroid patients with no goiter (55 +/- 29 mg), but they became hyperthyroid more rapidly. Thirteen patients were hypothyroid; none had TIC values above the normal range, and it was below 2.5 mg in 5 patients. A sequential study was undertaken in 11 euthyroid patients who had no detectable antithyroid antibodies. TIC did not increase during treatment in 2 patients; both developed hypothyroidism, which was transient in 1 despite continuation of amiodarone treatment. The TIC initially increased during amiodarone treatment in the other 9 patients, leveling off at the end of the first year. The TIC rose well above the upper limit of the normal range in 4 patients, of whom 2 became hyperthyroid during the second year of treatment. TIC remained within the normal range in the other 5 patients, of whom 3 became hypothyroid after 12-24 months of treatment (1 subclinical, 2 overt). Although the TIC was significantly higher in the patients with hyperthyroidism than in the patients who remained euthyroid, the TIC test cannot be used to predict the occurrence of hyperthyroidism

  5. Quantitative measurement of left ventricular volume by SPECT

    International Nuclear Information System (INIS)

    Tsay, T.T.; Jaszczak, R.J.; Tsui, B.M.W.; Hawman, E.; Greer, K.L.; Coleman, R.E.

    1986-01-01

    To evaluate the accuracy of measuring left ventricular (LV) volume using SPECT images, an adjustable boundary detection algorithm was performed to optimize the estimated volume. The algorithm was based on combined first-and second-difference edge-enhancement operators weighted by a hybrid parameter α(0 < α < 1). A ventricular phantom placed inside an elliptical phantom containing two balsa wood ''lungs'' was used in the experimental measurements. Two LV volume determination methods were evaluated. In the pixel summing method, no optimal value was found. In the count summing method, the optimal value was 0.4, where the error is less than 10%. In patient studies, the estimated LV volumes determined by the count summing method with α = 0.4 agree with that determined by the cath. method

  6. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... capturing images of the thyroid gland from three different angles. You will need to remain still for ... Often, two separate uptake measurements are obtained at different times. For example, you may have uptake measurements ...

  7. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... your examination, blood tests may be performed to measure the level of thyroid hormones in your blood. ... device resembling a microphone that can detect and measure the amount of the radiotracer in a small ...

  8. Micro analysis of fringe field formed inside LDA measuring volume

    International Nuclear Information System (INIS)

    Ghosh, Abhijit; Nirala, A K

    2016-01-01

    In the present study we propose a technique for micro analysis of fringe field formed inside laser Doppler anemometry (LDA) measuring volume. Detailed knowledge of the fringe field obtained by this technique allows beam quality, alignment and fringe uniformity to be evaluated with greater precision and may be helpful for selection of an appropriate optical element for LDA system operation. A complete characterization of fringes formed at the measurement volume using conventional, as well as holographic optical elements, is presented. Results indicate the qualitative, as well as quantitative, improvement of fringes formed at the measurement volume by holographic optical elements. Hence, use of holographic optical elements in LDA systems may be advantageous for improving accuracy in the measurement. (paper)

  9. Volume Measurement in Solid Objects Using Artificial Vision Technique

    Science.gov (United States)

    Cordova-Fraga, T.; Martinez-Espinosa, J. C.; Bernal, J.; Huerta-Franco, R.; Sosa-Aquino, M.; Vargas-Luna, M.

    2004-09-01

    A simple system using artificial vision technique for measuring the volume of solid objects is described. The system is based on the acquisition of an image sequence of the object while it is rotating on an automated mechanism controlled by a PC. Volumes of different objects such as a sphere, a cylinder and also a carrot were measured. The proposed algorithm was developed in environment LabView 6.1. This technique can be very useful when it is applied to measure the human body for evaluating its body composition.

  10. [Measurement of intracranial hematoma volume by personal computer].

    Science.gov (United States)

    DU, Wanping; Tan, Lihua; Zhai, Ning; Zhou, Shunke; Wang, Rui; Xue, Gongshi; Xiao, An

    2011-01-01

    To explore the method for intracranial hematoma volume measurement by the personal computer. Forty cases of various intracranial hematomas were measured by the computer tomography with quantitative software and personal computer with Photoshop CS3 software, respectively. the data from the 2 methods were analyzed and compared. There was no difference between the data from the computer tomography and the personal computer (P>0.05). The personal computer with Photoshop CS3 software can measure the volume of various intracranial hematomas precisely, rapidly and simply. It should be recommended in the clinical medicolegal identification.

  11. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  12. Finding the Density of Objects without Measuring Mass and Volume

    Science.gov (United States)

    Mumba, Frackson; Tsige, Mesfin

    2007-01-01

    A simple method based on the moment of forces and Archimedes' principle is described for finding density without measuring the mass and volume of an object. The method involves balancing two unknown objects of masses M[subscript 1] and M[subscript 2] on each side of a pivot on a metre rule and measuring their corresponding moment arms. The object…

  13. Calibration of the identiFINDER detector for the iodine measurement in thyroid using the Monte Carlo method

    International Nuclear Information System (INIS)

    Ramos M, D.; Yera S, Y.; Lopez B, G. M.; Acosta R, N.; Vergara G, A.

    2014-08-01

    This work is based on the determination of the detection efficiency of 125 I and 131 I in thyroid of the identiFINDER detector using the Monte Carlo method. The suitability of the calibration method is analyzed, when comparing the results of the direct Monte Carlo method with the corrected, choosing the latter because the differences with the real efficiency stayed below 10%. To simulate the detector their geometric parameters were optimized using a tomographic study, what allowed the uncertainties minimization of the estimates. Finally were obtained the simulations of the detector geometry-point source to find the correction factors to 5 cm, 15 cm and 25 cm, and those corresponding to the detector-simulator arrangement for the method validation and final calculation of the efficiency, demonstrating that in the Monte Carlo method implementation if simulates at a greater distance than the used in the Laboratory measurements an efficiency overestimation can be obtained, while if simulates at a shorter distance this will be underestimated, so should be simulated at the same distance to which will be measured in the reality. Also, is achieved the obtaining of the efficiency curves and minimum detectable activity for the measurement of 131 I and 125 I. In general is achieved the implementation of the Monte Carlo methodology for the identiFINDER calibration with the purpose of estimating the measured activity of iodine in thyroid. This method represents an ideal way to replace the lack of patterns solutions and simulators assuring the capacities of the Internal Contamination Laboratory of the Centro de Proteccion e Higiene de las Radiaciones are always calibrated for the iodine measurement in thyroid. (author)

  14. Association of High Vitamin D Status with Low Circulating Thyroid-Stimulating Hormone Independent of Thyroid Hormone Levels in Middle-Aged and Elderly Males

    Directory of Open Access Journals (Sweden)

    Qingqing Zhang

    2014-01-01

    Full Text Available Background. A recent study has reported that high circulating 25-hydroxyvitamin D [25(OHD] is associated with low circulating thyroid-stimulating hormone (TSH levels, but only in younger individuals. The goal of the present study was to explore the relationship between vitamin D status and circulating TSH levels with thyroid autoimmunity and thyroid hormone levels taken into consideration in a population-based health survey of middle-aged and elderly individuals. Methods. A total of 1,424 Chinese adults, aged 41–78 years, were enrolled in this cross-sectional study. Serum levels of 25(OHD, TSH, thyroid hormones, and thyroid autoantibodies were measured. Results. The prevalence of vitamin D insufficiency was 94.29% in males and 97.22% in females, and the prevalence of vitamin D deficiency was 55.61% in males and 69.64% in females. Vitamin D status was not associated with positive thyroid autoantibodies after controlling for age, gender, body mass index, and smoking status. Higher 25(OHD levels were associated with lower TSH levels after controlling for age, FT4 and FT3 levels, thyroid volume, the presence of thyroid nodule(s, and smoking status in males. Conclusion. High vitamin D status in middle-aged and elderly males was associated with low circulating TSH levels independent of thyroid hormone levels.

  15. Individualised dosimetry in patients with differentiated thyroid cancer based on external dose-rate. Optimisation of the number of measurements.

    Science.gov (United States)

    Bautista-Ballesteros, J A; Torres-Espallardo, I; Borrelli, P; Rivas-Sanchez, A; Bello, P; Martí-Bonmatí, L

    2016-01-01

    To compare the results of individual dosimetry in differentiated thyroid cancer patients treated with (131)I at our centre with the established limits and dosimetry results of published studies. Analysis of the optimal number of measurements necessary to reduce the impact of dosimetry for the comfort of the patient and, secondly, on the workload of health workers. Dosimetry was performed in the Nuclear Medicine Department of the University and Polytechnic Hospital La Fe, on 29 patients suffering from differentiated thyroid cancer and treated with activities between 1.02 and 5.51 GBq (mean 2.68 GBq) of (131)I. The Spanish Society of Medical Physics (SEFM) protocol was used, based on measurements of external dose rate adjusted to a bi-exponential curve according to a two compartment model. Different dosimetries were performed on each patient, taking different selections of the available measurements in order to find the optimal number. Results are well below the dosimetry limits, and are consistent with those obtained in other centres. The number of measurements can be reduced from 5, as proposed in the SEFM protocol, to 4 without significant loss of accuracy. Further reducing measures may be justified in individual cases. The values obtained for the dosimetry quantities are significantly below the established limits. A reduction in measurements can be assumed at the cost of a moderate increase in uncertainty, benefiting the patient. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  16. Mathematical modeling of a survey-meter used to measure radioactivity in human thyroids: Monte Carlo calculations of the device response and uncertainties

    Science.gov (United States)

    Khrutchinsky, Arkady; Drozdovitch, Vladimir; Kutsen, Semion; Minenko, Victor; Khrouch, Valeri; Luckyanov, Nickolas; Voillequé, Paul; Bouville, André

    2012-01-01

    This paper presents results of Monte Carlo modeling of the SRP-68-01 survey meter used to measure exposure rates near the thyroid glands of persons exposed to radioactivity following the Chernobyl accident. This device was not designed to measure radioactivity in humans. To estimate the uncertainty associated with the measurement results, a mathematical model of the SRP-68-01 survey meter was developed and verified. A Monte Carlo method of numerical simulation of radiation transport has been used to calculate the calibration factor for the device and evaluate its uncertainty. The SRP-68-01 survey meter scale coefficient, an important characteristic of the device, was also estimated in this study. The calibration factors of the survey meter were calculated for 131I, 132I, 133I, and 135I content in the thyroid gland for six age groups of population: newborns; children aged 1 yr, 5 yr, 10 yr, 15 yr; and adults. A realistic scenario of direct thyroid measurements with an “extended” neck was used to calculate the calibration factors for newborns and one-year-olds. Uncertainties in the device calibration factors due to variability of the device scale coefficient, variability in thyroid mass and statistical uncertainty of Monte Carlo method were evaluated. Relative uncertainties in the calibration factor estimates were found to be from 0.06 for children aged 1 yr to 0.1 for 10-yr and 15-yr children. The positioning errors of the detector during measurements deviate mainly in one direction from the estimated calibration factors. Deviations of the device position from the proper geometry of measurements were found to lead to overestimation of the calibration factor by up to 24 percent for adults and up to 60 percent for 1-yr children. The results of this study improve the estimates of 131I thyroidal content and, consequently, thyroid dose estimates that are derived from direct thyroid measurements performed in Belarus shortly after the Chernobyl accident. PMID:22245289

  17. Stereology of the thyroid gland in Indo-Pacific bottlenose dolphin (Tursiops aduncus in comparison with human (Homo sapiens: quantitative and functional implications.

    Directory of Open Access Journals (Sweden)

    Brian Chin Wing Kot

    Full Text Available The mammalian thyroid gland maintains basal metabolism in tissues for optimal function. Determining thyroid volume is important in assessing growth and involution. Volume estimation is also important in stereological studies. Direct measurements of colloid volume and nuclear-to-cytoplasmic ratio of the follicular cells may provide important information about thyroid gland function such as hormone storage and secretion, which helps understand the changes at morphological and functional levels. The present study determined the colloid volume using simple stereological principle and the nuclear-to-cytoplasmic ratio of 4 Indo-Pacific bottlenose dolphins and 2 human thyroid glands. In both dolphin and human thyroid glands, the size of the follicles tended to be quite variable. The distribution of large and small follicles within the thyroid gland was also found to be random in both the dolphin and human thyroid gland; however, the size of follicles appeared to decrease as a function of increasing age in the dolphin thyroid gland. The mean colloid volume of the dolphin thyroid gland and human thyroid gland was 1.22×10(5 µm(3 and 7.02×10(5 µm(3 respectively. The dolphin and human subjects had a significant difference in the mean colloid volume. The mean N/C ratio of the dolphin thyroid follicular epithelia and human follicular epithelia was 0.50 and 0.64 respectively. The dolphin and human subjects had a significant difference in the mean N/C ratio. This information contributes to understanding dolphin thyroid physiology and its structural adaptations to meet the physical demands of the aquatic environment, and aids with ultrasonography and corrective therapy in live subjects.

  18. Stereology of the thyroid gland in Indo-Pacific bottlenose dolphin (Tursiops aduncus) in comparison with human (Homo sapiens): quantitative and functional implications.

    Science.gov (United States)

    Kot, Brian Chin Wing; Lau, Thomas Yue Huen; Cheng, Sammy Chi Him

    2013-01-01

    The mammalian thyroid gland maintains basal metabolism in tissues for optimal function. Determining thyroid volume is important in assessing growth and involution. Volume estimation is also important in stereological studies. Direct measurements of colloid volume and nuclear-to-cytoplasmic ratio of the follicular cells may provide important information about thyroid gland function such as hormone storage and secretion, which helps understand the changes at morphological and functional levels. The present study determined the colloid volume using simple stereological principle and the nuclear-to-cytoplasmic ratio of 4 Indo-Pacific bottlenose dolphins and 2 human thyroid glands. In both dolphin and human thyroid glands, the size of the follicles tended to be quite variable. The distribution of large and small follicles within the thyroid gland was also found to be random in both the dolphin and human thyroid gland; however, the size of follicles appeared to decrease as a function of increasing age in the dolphin thyroid gland. The mean colloid volume of the dolphin thyroid gland and human thyroid gland was 1.22×10(5) µm(3) and 7.02×10(5) µm(3) respectively. The dolphin and human subjects had a significant difference in the mean colloid volume. The mean N/C ratio of the dolphin thyroid follicular epithelia and human follicular epithelia was 0.50 and 0.64 respectively. The dolphin and human subjects had a significant difference in the mean N/C ratio. This information contributes to understanding dolphin thyroid physiology and its structural adaptations to meet the physical demands of the aquatic environment, and aids with ultrasonography and corrective therapy in live subjects.

  19. Amiodarone and the thyroid.

    Science.gov (United States)

    Jabrocka-Hybel, Agata; Bednarczuk, Tomasz; Bartalena, Luigi; Pach, Dorota; Ruchała, Marek; Kamiński, Grzegorz; Kostecka-Matyja, Marta; Hubalewska-Dydejczyk, Alicja

    2015-01-01

    Amiodarone, a benzofuranic iodine-rich antiarrhythmic drug, causes thyroid dysfunction in 15-20% of cases. Amiodarone can cause both hypothyroidism (AIH, amiodarone-induced hypothyroidism) and thyrotoxicosis (AIT, amiodarone-induced thyrotoxicosis). AIH is treated by L-thyroxin replacement and does not need amiodarone discontinuation. There are two main forms of AIT: type 1, a form of true iodine-induced hyperthyroidism; and type 2, a drug-induced destructive thyroiditis. However, mixed/indefinite forms exist, contributed to by both pathogenic mechanisms. Type 1 AIT usually occurs in diseased thyroid glands, whereas type 2 AIT develops in substantially normal thyroid glands. Thioamides represent the first-line treatment for type 1 AIT, but iodine-replete glands are poorly responsive; sodium/potassium perchlorate, by inhibiting thyroidal iodine uptake, may increase the response to thioamides. Type 2 AIT is best treated by oral glucocorticoids. Response depends on thyroid volume and severity of thyrotoxicosis. Mixed/indefinite forms may require a combination of thioamides, potassium perchlorate, and steroids. Radioiodine treatment is usually not feasible because amiodarone-related iodine load decreases thyroidal radioiodine uptake. Thyroidectomy represents an important and helpful option in cases resistant to medical therapy. Surgery performed by a skilled surgeon may represent an emergent treatment in patients who have severe cardiac dysfunction.

  20. A case of synchronous hurthle cell adenoma of thyroid and para thyroid adenoma

    Directory of Open Access Journals (Sweden)

    Masoome Tohidi

    2015-04-01

    Full Text Available Synchronous hurthle cell adenoma of thyroid and para thyroid adenoma is very rare .Here we dicuss a 46 year old woman who presented with a thyroid nodule. Thyroid function test was normal but she had mild hypercalcemia. Fine needle aspiration of thyroid nodule was done that it was suspecious to follicular neoplasm or follicular variant of papillary thyroid cancer .Then the patient underwent thyroidectomy. In surgical specimen hurthle cell adenoma of thyroid and parathyroid adenoma was confirmed.Measurment of serum calcium is recommended in patients who are candidate for thyroid surgery.

  1. Radiation and thyroid cancer

    International Nuclear Information System (INIS)

    Lazo, Edward

    2014-01-01

    An International Workshop on Radiation and Thyroid Cancer took place on 21-23 February 2014 in Tokyo, Japan, to support the efforts of the Fukushima Prefecture and the Japanese government in enhancing public health measures following the Fukushima Daiichi nuclear power plant accident in March 2011. The workshop, which was designed to develop a state-of-the-art scientific understanding of thyroid cancer in children and of radiation-induced thyroid cancer (papillary carcinoma) in particular, was co-organised by the Japanese Ministry of the Environment (MOE), the Fukushima Medical University (FMU) and the OECD Nuclear Energy Agency (NEA). It brought together the world's top experts in the field, including medical doctors, epidemiologists and radiological risk assessment specialists from ten countries. Although rare, thyroid cancer occurs naturally, with the risk of developing a thyroid cancer increasing with age. Cases are usually identified when a thyroid carcinogenic nodule grows enough to be felt with a patient's fingers, at which point the patient visits a medical doctor to identify the nature of the growth. In many countries around the world, the incidence rate of naturally occurring thyroid cancer is on the order of less than 1 per year per 100 000 children (from ages 0 to 18). Statistically, this rate appears to be increasing in many countries, with young girls slightly more at risk than young boys. A second but very different means of detecting thyroid cancer cases is through thyroid ultrasound screening examinations on subjects who do not demonstrate any symptoms. Ultrasound screening is a more sensitive approach that can detect very small nodules (< 5 mm) and cysts (< 20 mm) which would not normally be perceived through simple palpitation. However, because thyroid ultrasound screening examinations are much more effective, the number of thyroid cancer cases per examination will normally be larger than the number per capita found through national cancer

  2. Representative volume element of asphalt pavement for electromagnetic measurements

    Directory of Open Access Journals (Sweden)

    Terhi Pellinen

    2015-02-01

    Full Text Available The motivation for this study was to investigate the representative volume element (RVE needed to correlate the nondestructive electromagnetic (EM measurements with the conventional destructive asphalt pavement quality control measurements. A large pavement rehabilitation contract was used as the test site for the experiment. Pavement cores were drilled from the same locations where the stationary and continuous Ground Penetrating Radar (GPR measurements were obtained. Laboratory measurements included testing the bulk density of cores using two methods, the surface-saturated dry method and determining bulk density by dimensions. Also, Vector Network Analyzer (VNA and the through specimen transmission configuration were employed at microwave frequencies to measure the reference dielectric constant of cores using two different footprint areas and therefore volume elements. The RVE for EM measurements turns out to be frequency dependent; therefore in addition to being dependent on asphalt mixture type and method of obtaining bulk density, it is dependent on the resolution of the EM method used. Then, although the average bulk property results agreed with theoretical formulations of higher core air void content giving a lower dielectric constant, for the individual cores there was no correlation for the VNA measurements because the volume element seizes deviated. Similarly, GPR technique was unable to capture the spatial variation of pavement air voids measured from the 150-mm drill cores. More research is needed to determine the usable RVE for asphalt.

  3. An improved quantitative measurement for thyroid cancer detection based on elastography

    International Nuclear Information System (INIS)

    Ding Jianrui; Cheng, H.D.; Huang Jianhua; Zhang Yingtao; Liu Jiafeng

    2012-01-01

    Objective: To evaluate color thyroid elastograms quantitatively and objectively. Materials and methods: 125 cases (56 malignant and 69 benign) were collected with the HITACHI Vision 900 system (Hitachi Medical System, Tokyo, Japan) and a liner-array-transducer of 6–13 MHz. Standard of reference was cytology (FNA—fine needle aspiration) or histology (core biopsy). The original color thyroid elastograms were transferred from red, green, blue (RGB) color space to hue, saturation, value (HSV) color space. Then, hard area ratio was defined. Finally, a SVM classifier was used to classify thyroid nodules into benign and malignant. The relation between the performance and hard threshold was fully investigated and studied. Results: The classification accuracy changed with the hard threshold, and reached maximum (95.2%) at some values (from 144 to 152). It was higher than strain ratio (87.2%) and color score (83.2%). It was also higher than the one of our previous study (93.6%). Conclusion: The hard area ratio is an important feature of elastogram, and appropriately selected hard threshold can improve classification accuracy.

  4. Clinical Relevance of Brain Volume Measures in Multiple Sclerosis

    DEFF Research Database (Denmark)

    De Stefano, Nicola; Airas, Laura; Grigoriadis, Nikolaos

    2014-01-01

    (e.g. SIENA [Structural Image Evaluation using Normalization of Atrophy]). Although these methods are sensitive and reproducible, caution must be exercised when interpreting brain volume data, as numerous factors (e.g. pseudoatrophy) may have a confounding effect on measurements, especially......Multiple sclerosis (MS) is a chronic disease with an inflammatory and neurodegenerative pathology. Axonal loss and neurodegeneration occurs early in the disease course and may lead to irreversible neurological impairment. Changes in brain volume, observed from the earliest stage of MS...... and proceeding throughout the disease course, may be an accurate measure of neurodegeneration and tissue damage. There are a number of magnetic resonance imaging-based methods for determining global or regional brain volume, including cross-sectional (e.g. brain parenchymal fraction) and longitudinal techniques...

  5. Thyroid nodule

    Science.gov (United States)

    ... symptoms, including: Fatigue Palpitations Chest pain Memory loss Thyroid nodules are sometimes found in people who have Hashimoto's disease. This may cause symptoms of an underactive thyroid gland, such as: Dry ...

  6. Thyroid Cancer

    Science.gov (United States)

    ... body work normally. There are several types of cancer of the thyroid gland. You are at greater ... imaging tests, and a biopsy to diagnose thyroid cancer. Treatment depends on the type of cancer you ...

  7. Thyroid Disease

    Science.gov (United States)

    ... for several months or longer, a condition called amenorrhea . If your body's immune system causes thyroid disease, ... at all for several months or longer (called amenorrhea). How does thyroid disease affect pregnancy? Pregnancy-related ...

  8. Challenges in interpretation of thyroid function tests in pregnant women with autoimmune thyroid disease

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Bliddal, Sofie; Rasmussen, Åse Krogh

    2011-01-01

    Physiological changes during gestation are important to be aware of in measurement and interpretation of thyroid function tests in women with autoimmune thyroid diseases. Thyroid autoimmune activity is decreasing in pregnancy. Measurement of serum TSH is the first-line screening variable....... Measurement of antithyroperoxidase and/or TSH receptor antibodies adds to the differential diagnosis of autoimmune and nonautoimmune thyroid diseases....... for thyroid dysfunction also in pregnancy. However, using serum TSH for control of treatment of maternal thyroid autoimmunity infers a risk for compromised foetal development. Peripheral thyroid hormone values are highly different among laboratories, and there is a need for laboratory-specific gestational age...

  9. Stereographic measurement of orbital volume, a digital reproducible evaluation method.

    Science.gov (United States)

    Mottini, Matthias; Wolf, Christian A; Seyed Jafari, S Morteza; Katsoulis, Konstantinos; Schaller, Benoît

    2017-10-01

    Up to date, no standardised reproducible orbital volume measurement method is available. Therefore, this study aimed to investigate the accuracy of a new measurement method, which delineates the boundaries of orbital cavity three-dimensionally (3D). In order to calculate the orbital volume from axial CT slice images of the patients, using our first described measurement method, the segmentation of the orbital cavity and the bony skull was performed using Amira 3D Analysis Software. The files were then imported into the Blender program. The stereographic skull model was aligned based on the Frankfurt horizontal plane and superposed according to defined anatomical reference points. The anterior sectional plane ran through the most posterior section of the lacrimal fossa and the farthest dorsal point of the anterior latero-orbital margin, which is positioned perpendicular to the Frankfurt horizontal plane. The volume of each orbital cavity was then determined automatically by the Blender program. The 10 consecutive subjects (5 female, 5 male) with mean age of 50.3±21.3 years were considered for analysis in the current study. The first investigator reported a mean orbital volume of 20.24±1.01 cm3 in the first and 20.25±1.03 cm3 in the second evaluation. Furthermore, the intraclass correlation coefficient (ICC) showed an excellent intrarater agreement (ICC=0.997). Additionally, the second investigator detected a mean orbital volume of 20.20±1.08 cm3 in his assessment, in which an excellent inter-rater agreement was found in ICC (ICC=0.994). This method provides a standardised and reproducible 3D approach to the measurement of the orbital volume. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Utilising Geological Field Measurements and Historic Eruption Volumes to Estimate the Volume of Santorini's Magma Chamber

    Science.gov (United States)

    Browning, J.; Drymoni, K.; Gudmundsson, A.

    2015-12-01

    An understanding of the amount of magma available to supply any given eruption is useful for determining the potential eruption magnitude and duration. Geodetic measurements and inversion techniques are often used to constrain volume changes within magma chambers, as well as constrain location and depth, but such models are incapable of calculating total magma storage. For example, during the 2012 unrest period at Santorini volcano, approximately 0.021 km3 of new magma entered a shallow chamber residing at around 4 km below the surface. This type of event is not unusual, and is in fact a necessary condition for the formation of a long-lived shallow chamber, of which Santorini must possess. The period of unrest ended without culminating in eruption, i.e the amount of magma which entered the chamber was insufficient to break the chamber and force magma further towards the surface. We combine previously published data on the volume of recent eruptions at Santorini together with geodetic measurements. Measurements of dykes within the caldera wall provide an estimate of the volume of magma transported during eruptions, assuming the dyke does not become arrested. When the combined volume of a dyke and eruption are known (Ve) they can be used to estimate using fracture mechanics principles and poro-elastic constraints the size of an underlying shallow magma chamber. We present field measurements of dykes within Santorini caldera and provide an analytical method to estimate the volume of magma contained underneath Santorini caldera. In addition we postulate the potential volume of magma required as input from deeper sources to switch the shallow magma chamber from an equilibrium setting to one where the pressure inside the chamber exceeds the surrounding host rocks tensile strength, a condition necessary to form a dyke and a possible eruption.

  11. Accuracy of Prader orchidometer in measuring testicular volume

    African Journals Online (AJOL)

    2012-10-21

    Oct 21, 2012 ... [3] Reliable and accurate determination of testicular volume is of great benefit in evaluating patients with a variety of disorders affecting testicular growth, development, and function. Studies in infertile .... Secondly, he did not measure the actual size of testes by water displacement like was done in this study ...

  12. Fuel pins volume measuring installation in hot cells

    International Nuclear Information System (INIS)

    Prokudanov, D.L.; Troitskii, S.V.

    1987-11-01

    The NIIAR Institute has elaborated a method and concepted an installation for determining precisely the fuel pin volume. This determination is based on a fluid measurement level by ultrason. The operation principle and the installation diagram are indicated in this document [fr

  13. Reliability and Accuracy of Brain Volume Measurement on MR Imaging

    DEFF Research Database (Denmark)

    Yamagchii, Kechiro; Lassen, Anders; Ring, Poul

    1998-01-01

    Yamaguchi, K., Lassen, A. And Ring, P. Reliability and Accuracy of Brain Volume Measurement on MR Imaging. Abstract at ESMRMB98 European Society for Magnetic Resonance in Medicine and Biology, Geneva, Sept 17-20, 1998 Danish Research Center for Magnetic Resonance, Hvidovre University Hospital...

  14. Challenges in Interpretation of Thyroid Function Tests in Pregnant Women with Autoimmune Thyroid Disease

    Directory of Open Access Journals (Sweden)

    Ulla Feldt-Rasmussen

    2011-01-01

    Full Text Available Physiological changes during gestation are important to be aware of in measurement and interpretation of thyroid function tests in women with autoimmune thyroid diseases. Thyroid autoimmune activity is decreasing in pregnancy. Measurement of serum TSH is the first-line screening variable for thyroid dysfunction also in pregnancy. However, using serum TSH for control of treatment of maternal thyroid autoimmunity infers a risk for compromised foetal development. Peripheral thyroid hormone values are highly different among laboratories, and there is a need for laboratory-specific gestational age-related reference ranges. Equally important, the intraindividual variability of the thyroid hormone measurements is much narrower than the interindividual variation (reflecting the reference interval. The best laboratory assessment of thyroid function is a free thyroid hormone estimate combined with TSH. Measurement of antithyroperoxidase and/or TSH receptor antibodies adds to the differential diagnosis of autoimmune and nonautoimmune thyroid diseases.

  15. Gastric residual volume (GRV) and gastric contents measurement by refractometry.

    Science.gov (United States)

    Chang, Wei-Kuo; McClave, Stephen A; Hsieh, Chung-Bao; Chao, You-Chen

    2007-01-01

    Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion vs delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.

  16. Effect of patient Age on surgical outcomes for Graves’ disease: a case–control study of 100 consecutive patients at a high volume thyroid surgical center

    Directory of Open Access Journals (Sweden)

    Breuer Christopher K

    2013-01-01

    Full Text Available Abstract Objective To compare outcomes between children ( Summary of background data Reported complication rates for children undergoing surgery for Graves’ disease are worse than for adults. Methods 100 consecutive patients (32 children; 68 adults who underwent total thyroidectomy for Graves’ disease (GD by a high-volume endocrine surgery team from were compared. Results The mean patient age was 9.7 yrs (range 3.4-17.9 yrs in children versus 44.9 yrs (range 18.4-84.2 yrs in adults. Operative times were longer in children (2.18 ± 0.08 hrs than in adults (1.66 ± 0.03 hrs (p = 0.003. Pediatric thyroid specimens averaged 38.6.0 ± 8.9 gm (range: 9–293 gm and adult thyroid specimens averaged 48.0 ± 6.4 gm (range: 6.6-203 gm (p = 0.34. Thyroid to body weight ratios were greater in children (0.94 ± 0.11 gm/kg than adults (0.67 ± 0.8 gm/kg (p = 0.05. In all patients, the hyperthyroid state resolved after surgery. There was no operative mortality, recurrence, or permanent hypoparathyroidism. Transient post-operative hypocalcemia requiring calcium infusion was greater in children than adults (6/32 vs. 1/68; p = 0.004. Transient recurrent laryngeal nerve dysfunction occurred in two children and in no adults (p = 0.32. Postoperative hematoma occurred in two adults and in no children (p = 0.46. The length of stay was longer for children (1.41 ± 0.12 days than for adults (1.03 ±0.03 days (p = 0.004. Conclusion Surgical management of GD is technically more challenging in children as evidenced by longer operative times. Whereas temporary hypocalcemia occurs more commonly in children than adults, the risks of major complications including disease recurrence, permanent hypoparathyroidism, recurrent laryngeal nerve injury, or neck hematoma were indistinguishable. These data suggest that excellent and equivalent outcomes can be achieved for GD surgery in children and adults when care is rendered

  17. Thyroid Metastasis from Breast Carcinoma Accompanied by Papillary Thyroid Carcinoma

    Directory of Open Access Journals (Sweden)

    Song-I Yang

    2014-07-01

    Full Text Available Metastasis to the thyroid gland is very rare. Recently, we experienced a case of thyroid metastasis from breast cancer accompanying a papillary thyroid. A 51-year-old female patient presented with a palpated lymph node on her left lateral neck. The patient had undergone a left modified radical mastectomy followed by chemotherapy and hormonal therapy 12 years prior. Ultrasonography of the neck revealed a malignant looking nodule at the left thyroid lobe, measuring 0.9 × 0.9 cm, and several cystic nodules at the right thyroid lobe. Ultrasonography of the neck additionally revealed a malignant looking lymph node at the right level VI. Fine-needle aspiration of the left thyroid lobe resulted in a diagnosis of papillary thyroid carcinoma and that of the right level VI in Hurthle cell lesion. The patient had a total thyroidectomy with selective dissection of the left neck node. Pathologic assessment of the specimen revealed metastatic carcinoma from the breast carcinoma and papillary thyroid carcinoma. Although the thyroid gland is highly vascularized, metastasis of malignant tumors to the thyroid is relatively rare and detection of metastasis shows a low frequency. So a careful evaluation of thyroid tumor should be considered in a patient with a history of other malignancy.

  18. Evaluation the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo Modesto Gadelha

    2011-01-01

    In vivo monitoring techniques consist of identification and quantification of radionuclides present in the whole body and specific organs and tissues. In Vivo monitoring requires the use of detedors which are sensitive to the radiation emitted by radionuclides present in the monitored individual. The results obtained in measurements may present small uncertainties which are within pre-set limits in monitoring programs for occupationally exposed individuais. However, any device used to determine physical quantities present uncertainties in the measured values. The total uncertainty of a measurement result is estimated from the propagation of the uncertainties associated to each parameter of the calculation. This study aims to evaluate the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid, in comparison to the suggested in the General Guide for Estimating Effective Doses from Monitoring Data (Project IDEAS/European Community). The reference values used were the ones for high-energy photons (>100 keV). The measurement uncertainties were divided into two categories: type A and type B. The component of type A represents the statistical fluctuation in the counting of the standard source. Regarding type B, the following variations were presented: detector positioning over the phantom; variation of background radiation; thickness of the overlay tissue over the monitored organ, distribution of the activity in the organ. Besides the parameters suggested by the IDEAS Guide, it has also been evaluated the fluctuation of the counting due to the phantom repositioning, which represents the reproducibility of the measurement geometry. Measurements were performed at the Whole Body Counter Unit of IRD using a scintillation detector Nal (Tl) 3 x3 and a neck-thyroid phantom developed at LABMIVIRD. Scattering factors were calculated and compared in different counting geometries. The results of this study show that the

  19. [Thyroid cancer].

    Science.gov (United States)

    Nagayama, Yuji

    2012-03-01

    The thyroid glands are a vulnerable organ to ionizing radiation. Indeed the epidemiological studies have revealed an increase in the incidences of thyroid cancer among atomic bomb survivors in Hiroshima and Nagasaki and radiation casualties in Chernobyl. The carcinogenic risk for the thyroids is dependent on radiation dose, and higher in younger people. Recent advances in molecular biology contribute to clarify the mechanisms for thyroid carcinogenesis at genetic and molecular levels. Here radiation-induced thyroid carcinogenesis is reviewed from epidemiological data to basic research.

  20. Anterior chamber volume. Its measurement and clinical application.

    Science.gov (United States)

    Coakes, R L; Lloyd-Jones, D; Hitchings, R A

    1979-04-01

    Measurement of anterior chamber volume is discussed and attention drawn to a new, convenient slit-image method, which was used to study anterior chamber depth and volume before and after prophylactic peripheral iridectomy in the fellow eyes of patients presenting with unilateral acute angle-closure glaucoma. There was no significant change in depth after iridectomy but the mean anterior chamber volume increased significantly (P less than 0.01), by nearly 3 per cent. This increase was due to elimination of peripheral iris bombé which was not present in two control groups of normal eyes, one matched for anterior chamber depth and the other for age and refraction. Peripheral iris bombé may be a quantifiable factor predisposing to the development of acute angle-closure glaucoma.

  1. Measurement of maxillary sinus volume using Computed Tomography

    International Nuclear Information System (INIS)

    Park, Chang Hee; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    To propose a standard value for the maxillary sinus volume of a normal Korean adult by measuring the width and height of the sinus and analyzing their correlation and the difference of the sinus size respectively between sexes, and on the right and left sides. Fifty-two (95 maxillary sinuses) out of 20 years or over aged patients who had taken CT in the Department of Dental Radiology, Yonsei University, Dental Hospital, between February 1997 and July 1999 who were no specific symptom, prominent bony septa, pathosis, clinical asymmetry and history of surgery in the maxillary sinus were retrospectively analyzed. The mean transverse width, antero-posterior width, height and volume of the normal Korean adult's maxillary sinuses were 28.33 mm, 39.69 mm, 46.60 mm and 21.90 cm 3 , respectively. There was a significant sex difference in the sinus volume (p<0.05). In the mean antero-posterior width, height and volume of the sinus, no significant difference was observed between both sides. All four measurements showed a significant correlation between both sides (p<0.0001). The widths and height of the sinus all showed a significant correlation with the sinus volume (p<0.0001). In the Korean normal adult's maxillary sinus, males tended to be larger than females. Except for the transverse width, all of the measurements showed no significant difference between the right and left side, but significant correlations in the four measurements between both sides were observed. Thus, the overgrowth or undergrowth in the unilateral maxillary sinus may suggest a certain pathosis or developmental abnormalities in the maxillary sinus.

  2. Density and volume measurements of reprocessing plant feed

    International Nuclear Information System (INIS)

    Platzer, R.; Carrier, M.; Neuilly, M.; Dedaldechamp, P.

    1985-05-01

    A theoretical study of the phenomenon of gas bubbles formation within a liquid led to an adaptation of the differential pressure bubbling technique for the measurement of liquid levels and densities in tanks. Experiments, carried out on a 800 liters tank with water and uranyl nitrate solutions had the double aim to study the precision attainable on volume and density measurements and to design a method for corrections of influencing factors. In parallel, procedures for transfer of known volumes through the use of siphons and for tank calibration by liquid level measurement are also investigated. The paper presents the first results obtained so far and the conclusions to be drawn for the elaboration of calibration and exploitation procedures suitables for use in reprocessing plants. The demonstration to transfer mass of solution with an accuracy of 0.1% is made [fr

  3. Measurement of thyroid-stimulating autoantibodies using a radioreceptor-assay (TRAK-assay)

    International Nuclear Information System (INIS)

    Becker, W.; Reiners, C.; Boerner, W.

    1983-01-01

    Autoantibodes against TSH-receptors were determined with a new radioreceptorassay (TRAK-assay) in 37 patients with untreated toxic diffus goitre and in 73 patients with non immunogenic thyroid diseases (41 healthy controls, respectively patients with euthyroid diffus or nodular goitres as well as 32 patients with toxic nodular goitre). The upper limit of normal is a TRAK-Titer of 20% without considerable fluctuations during titers in follow-up. According to this preliminary results it seems to be recommendable to treat patients with TRAK-titer F 20% (expected risk of relapse) primarily by operation or radioiodine. (orig.) [de

  4. Comparison of surface contamination monitors for in vivo measurement of 131I in thyroid

    International Nuclear Information System (INIS)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M.

    2015-01-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of 131 I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  5. Study of accurate volume measurement system for plutonium nitrate solution

    Energy Technology Data Exchange (ETDEWEB)

    Hosoma, T. [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works

    1998-12-01

    It is important for effective safeguarding of nuclear materials to establish a technique for accurate volume measurement of plutonium nitrate solution in accountancy tank. The volume of the solution can be estimated by two differential pressures between three dip-tubes, in which the air is purged by an compressor. One of the differential pressure corresponds to the density of the solution, and another corresponds to the surface level of the solution in the tank. The measurement of the differential pressure contains many uncertain errors, such as precision of pressure transducer, fluctuation of back-pressure, generation of bubbles at the front of the dip-tubes, non-uniformity of temperature and density of the solution, pressure drop in the dip-tube, and so on. The various excess pressures at the volume measurement are discussed and corrected by a reasonable method. High precision-differential pressure measurement system is developed with a quartz oscillation type transducer which converts a differential pressure to a digital signal. The developed system is used for inspection by the government and IAEA. (M. Suetake)

  6. Measurement of Gallbladder Volume with Ultrasonography in Pregnant Women

    Directory of Open Access Journals (Sweden)

    Sait Kapicioglu

    2000-01-01

    Full Text Available Fasting and postprandial gallbladder volumes were investigated using ultrasonography in three groups (10 subjects in each of healthy women: third trimester pregnant women, postpartum women up to 10 days after giving birth and nonpregnant controls. The scans were performed at 09:00 after a 12 h fast. After the basal measurement was taken, gallbladder volumes were rescanned in 15 min intervals for 60 mins. At the end of this period, all volunteers received a standard liquid test meal, and scans were performed again for 1 h. The mean basal gallbladder volume was 22.2±4.2 mL in the nonpregnant (control group. In the third trimester group, the basal volume was 37.8±10.5 mL – 70.5% higher than in the nonpregnant group (P<0.001. In the postpartum group, the mean basal volume was 37.9% lower (27.4±6.5 mL than that of the third trimester group (P<0.02. This basal volume was 23.6% greater than that of the control group (P<0.05. After administration of a test meal, the postprandial gallbladder volumes decreased during the first few minutes compared with baseline values. The volumes decreased by 10.2% to 39.8% (23.5±7.3 to 34.0±10.2; P<0.01 in the third trimester group, by 14.9% to 43.2% (16.6±4.3 to 23.3±5.5; P<0.01, 0.001 in the postpartum group and by 19.2% to 51.6% (11.9±3.5 to 17.9±3.6; P<0.02, 0.05, 0.01, 0.001 in the control group. Postprandial mean gallbladder volumes of the third trimester (P<0.02 and postpartum groups (P<0.02 to 0.01 were significantly different from those of the control group. In conclusion, incomplete emptying of the gallbladder after eating during the third trimester of pregnancy may contribute to cholesterol-gallstone formation, and pregnancy may thus increase the risk of gallstones.

  7. Distribution of Gs-alpha activating mutations in human thyroid tumors measured by subcloning.

    Science.gov (United States)

    Gorelov, V N; Gyenes, M; Neser, F; Röher, H D; Goretzki, P E

    1996-01-01

    In the search for the prevalence and distribution pattern of Gs-alpha gene mutations in differentiated thyroid tumors we examined 66 tumor tissue samples for the presence of mutations at "hot-spot" codons 201 and 227 using methods based on the polymerase chain reaction, subcloning and sequencing. The prevailing type of single-base substitution at codon 201 (71.4%) corresponded to the replacement of the wild-type sequence CGT (Arg) with TGT (Cys). The fragments of the Gs-alpha gene, including codon 201 or 227 from five follicular carcinomas and one follicular adenoma, were subcloned in Escherichia coli and it was found that the proportion of alleles with mutated codon 201 varied from 3.2% to 43%. Sequencing of the corresponding region has confirmed preliminary data indicating that the single-base changes CGT (Arg) to TGT (Cys) or CGT to CAT (His) occurred. There was only a weak correlation between the prevalence of cells bearing a mutation in the Gs-alpha gene and the level of Gs-alpha protein expression in the corresponding thyroid tumors.

  8. Thyroid dose measurement in patients undergoing to digital orthopantomography using optical stimulation dosimeters

    International Nuclear Information System (INIS)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T.; Avalos P, L. Y.

    2016-10-01

    In this paper we present the study of the thyroid equivalent dose in 300 patients undergoing to digital orthopantomography for dental treatment purposes using optical stimulation dosimeters (OSL) as in-vivo dosimeters, in order to verify if this is within acceptable parameters to prevent stochastic risks and to evaluate the possible risks caused by the technique used for this type of study (66 kv, 5 m A, 14.1 s). Three OSL dosimeters were used per patient, which were placed by the physician on the skin above the thyroid gland (using anatomical references and palpation); the information of the patients was divided by neck size and sex, finding a slight increase in the equivalent dose for female and small size patient, this combination being the group that was submitted to a higher dose. The results obtained were compared with similar studies performed on anthropomorphic mannequins with TLD dosimeters obtaining lower results. The equivalent dose found even though is below the threshold stochastic damage must be motorized for radiological protection and registration purposes. (Author)

  9. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    Science.gov (United States)

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  10. Measurement of cell volume changes by fluorescence self-quenching

    DEFF Research Database (Denmark)

    Hamann, Steffen; Kiilgaard, J.F.; Litman, Thomas

    2002-01-01

    At high concentrations, certain fluorophores undergo self-quenching, i.e., fluorescence intensity decreases with increasing fluorophore concentration. Accordingly, the self-quenching properties can be used for measuring water volume changes in lipid vesicles. In cells, quantitative determination...... of water transport using fluorescence self-quenching has been complicated by the requirement of relatively high (mM) and often toxic loading concentrations. Here we report a simple method that uses low (muM) loading concentrations of calcein-acetoxymethyl ester (calcein-AM) to obtain intracellular...... concentrations of the fluorophore calcein suitable for measurement of changes in cell water volume by self-quenching. The relationship between calcein fluorescence intensity, when excited at 490 nm (its excitation maximum), and calcein concentration was investigated in vitro and in various cultured cell types...

  11. Evaluation of Thyroid Disorders During Head-and-Neck Radiotherapy by Using Functional Analysis and Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Bakhshandeh, Mohsen [Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Hashemi, Bijan, E-mail: bhashemi@modares.ac.ir [Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Mahdavi, Seyed Rabie [Department of Medical Physics, Faculty of Medical Sciences, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Nikoofar, Alireza [Department of Radiation Oncology, Hafte-Tir Hospital, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Edraki, Hamid Reza [Department of Radiology, Panzdahe-Khordad Hospital, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Kazemnejad, Anoshirvan [Department of Biostatistics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of)

    2012-05-01

    Purpose: To evaluate thyroid function and vascular changes during radiotherapy for patients with head and neck cancer. Methods and Materials: Fifty patients treated with primary or postoperative radiotherapy for various cancers in the head and neck region were prospectively evaluated. The serum samples (triiodothyronine [T3], thyroxine [T4], thyroid-stimulating hormone [TSH], free triiodothyronine [FT3], and free thyroxine [FT4]), the echo level of the thyroid gland, and color Doppler ultrasonography (CDU) parameters of the right inferior thyroid artery (RITA) of the patients were measured before and at regular intervals during radiotherapy. The thyroid gland dose-volume histograms of the patients were derived from their computed tomography-based treatment plans. Results: There was a significant fall in TSH level (p < 0.0001) but an increase in FT4 (p < 0.0001) and T4 (p < 0.022) levels during the radiotherapy course. The threshold dose required to produce significant changes was 12 Gy (Biologically Effective Dose in 2-Gy fractions, BED{sub 2}). There were significant rises in the patients' pulsatility index, resistive index, peak systolic velocity, blood volume flow levels, and RITA diameter (p < 0.0001), as detected by CDU during radiotherapy, compared to those parameters measured before the treatment. Hypoechogenicity and irregular echo patterns (p < 0.0001) were seen during radiotherapy compared to those before treatment. There was significant Pearson's correlation between the CDU parameters and T4, FT4, and TSH levels. Conclusions: Radiation-induced thyroiditis is regarded as primary damage to the thyroid gland. Thyroiditis can subsequently result in hypothyroidism or hyperthyroidism. Our results demonstrated that changes in thyroid vessels occur during radiotherapy delivered to patients. Vessel changes also can be attributed to the late effect of radiation on the thyroid gland. The hypoechogenicity and irregular echo patterns observed in patients

  12. Short communication: Measuring feed volume and weight by machine vision.

    Science.gov (United States)

    Shelley, A N; Lau, D L; Stone, A E; Bewley, J M

    2016-01-01

    Individual dairy cow feed intake is closely related to the health and productive output of each cow, with healthy cows generally eating more feed than unhealthy cows. Incorporating the use of an automated system to monitor feed consumption for each cow may be beneficial for dairy farm management. This study examined the use of an inexpensive 3-dimensional video camera to measure feed volume, from which we derived feed weight. Proof-of-concept testing was conducted to determine the effectiveness and capability of the machine vision feed-scanning system and its possible use in feed intake monitoring. Such systems are ideal because they do not impede the workflow of the farm or interrupt feeding behavior. This is an improvement over existing systems that are labor and cost intensive. Our conducted experiments involve measuring feed volume at known weights, up to 22.68 kg, with the resulting volume and weight values analyzed by means of linear and quadratic least squares t-test regression analysis. The effects of feed positioning in the bin and near-range sensor limitations were also examined. The results showed that an estimation of feed weight from 3-dimensional scan of volume measurements could be made to within 0.5 kg of the physically measured feed weight using a digital scale. Future efforts will focus on extending this work to active bunks with multiple cows eating throughout the day and testing total mixed rations of varied composition. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Pregnancy and Thyroid Disease

    Science.gov (United States)

    ... thyroid medicines made with animal thyroid, such as Armour Thyroid, but is not useful for your baby’s ... the American Thyroid Association for the diagnosis and management of thyroid disease during pregnancy and the postpartum. ...

  14. American Thyroid Association

    Science.gov (United States)

    ... Professionals Thyroid Information Find out more information on Thyroid Disease. learn more Meetings ATA meeting dates, information, and ... News Press Releases & Announcements Thyroid Information (Brochures & FAQ's / Thyroid Diseases & Conditions) Cancer of the Thyroid Public Health Statements ...

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ... the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan is a ...

  16. Towards an optimized method of olive tree crown volume measurement.

    Science.gov (United States)

    Miranda-Fuentes, Antonio; Llorens, Jordi; Gamarra-Diezma, Juan L; Gil-Ribes, Jesús A; Gil, Emilio

    2015-02-04

    Accurate crown characterization of large isolated olive trees is vital for adjusting spray doses in three-dimensional crop agriculture. Among the many methodologies available, laser sensors have proved to be the most reliable and accurate. However, their operation is time consuming and requires specialist knowledge and so a simpler crown characterization method is required. To this end, three methods were evaluated and compared with LiDAR measurements to determine their accuracy: Vertical Crown Projected Area method (VCPA), Ellipsoid Volume method (VE) and Tree Silhouette Volume method (VTS). Trials were performed in three different kinds of olive tree plantations: intensive, adapted one-trunked traditional and traditional. In total, 55 trees were characterized. Results show that all three methods are appropriate to estimate the crown volume, reaching high coefficients of determination: R2 = 0.783, 0.843 and 0.824 for VCPA, VE and VTS, respectively. However, discrepancies arise when evaluating tree plantations separately, especially for traditional trees. Here, correlations between LiDAR volume and other parameters showed that the Mean Vector calculated for VCPA method showed the highest correlation for traditional trees, thus its use in traditional plantations is highly recommended.

  17. Towards an Optimized Method of Olive Tree Crown Volume Measurement

    Science.gov (United States)

    Miranda-Fuentes, Antonio; Llorens, Jordi; Gamarra-Diezma, Juan L.; Gil-Ribes, Jesús A.; Gil, Emilio

    2015-01-01

    Accurate crown characterization of large isolated olive trees is vital for adjusting spray doses in three-dimensional crop agriculture. Among the many methodologies available, laser sensors have proved to be the most reliable and accurate. However, their operation is time consuming and requires specialist knowledge and so a simpler crown characterization method is required. To this end, three methods were evaluated and compared with LiDAR measurements to determine their accuracy: Vertical Crown Projected Area method (VCPA), Ellipsoid Volume method (VE) and Tree Silhouette Volume method (VTS). Trials were performed in three different kinds of olive tree plantations: intensive, adapted one-trunked traditional and traditional. In total, 55 trees were characterized. Results show that all three methods are appropriate to estimate the crown volume, reaching high coefficients of determination: R2 = 0.783, 0.843 and 0.824 for VCPA, VE and VTS, respectively. However, discrepancies arise when evaluating tree plantations separately, especially for traditional trees. Here, correlations between LiDAR volume and other parameters showed that the Mean Vector calculated for VCPA method showed the highest correlation for traditional trees, thus its use in traditional plantations is highly recommended. PMID:25658396

  18. Towards an Optimized Method of Olive Tree Crown Volume Measurement

    Directory of Open Access Journals (Sweden)

    Antonio Miranda-Fuentes

    2015-02-01

    Full Text Available Accurate crown characterization of large isolated olive trees is vital for adjusting spray doses in three-dimensional crop agriculture. Among the many methodologies available, laser sensors have proved to be the most reliable and accurate. However, their operation is time consuming and requires specialist knowledge and so a simpler crown characterization method is required. To this end, three methods were evaluated and compared with LiDAR measurements to determine their accuracy: Vertical Crown Projected Area method (VCPA, Ellipsoid Volume method (VE and Tree Silhouette Volume method (VTS. Trials were performed in three different kinds of olive tree plantations: intensive, adapted one-trunked traditional and traditional. In total, 55 trees were characterized. Results show that all three methods are appropriate to estimate the crown volume, reaching high coefficients of determination: R2 = 0.783, 0.843 and 0.824 for VCPA, VE and VTS, respectively. However, discrepancies arise when evaluating tree plantations separately, especially for traditional trees. Here, correlations between LiDAR volume and other parameters showed that the Mean Vector calculated for VCPA method showed the highest correlation for traditional trees, thus its use in traditional plantations is highly recommended.

  19. New experimental procedure for measuring volume magnetostriction on powder samples

    International Nuclear Information System (INIS)

    Rivero, G.; Multigner, M.; Valdes, J.; Crespo, P.; Martinez, A.; Hernando, A.

    2005-01-01

    Conventional techniques used for volume magnetostriction measurements, as strain gauge or cantilever method, are very useful for ribbons or thin films but cannot be applied when the samples are in powder form. To overcome this problem a new experimental procedure has been developed. In this work, the experimental set-up is described, together with the results obtained in amorphous FeCuZr powders, which exhibit a strong dependence of the magnetization on the strength of the applied magnetic field. The magnetostriction measurements presented in this work point out that this dependence is related to a magnetovolume effect

  20. Challenges in interpretation of thyroid function tests in pregnant women with autoimmune thyroid disease

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Bliddal, Sofie; Rasmussen, Åse Krogh

    2011-01-01

    Physiological changes during gestation are important to be aware of in measurement and interpretation of thyroid function tests in women with autoimmune thyroid diseases. Thyroid autoimmune activity is decreasing in pregnancy. Measurement of serum TSH is the first-line screening variable for thyr......Physiological changes during gestation are important to be aware of in measurement and interpretation of thyroid function tests in women with autoimmune thyroid diseases. Thyroid autoimmune activity is decreasing in pregnancy. Measurement of serum TSH is the first-line screening variable...

  1. Harmonization of Serum Thyroid-Stimulating Hormone Measurements Paves the Way for the Adoption of a More Uniform Reference Interval.

    Science.gov (United States)

    Thienpont, Linda M; Van Uytfanghe, Katleen; De Grande, Linde A C; Reynders, Dries; Das, Barnali; Faix, James D; MacKenzie, Finlay; Decallonne, Brigitte; Hishinuma, Akira; Lapauw, Bruno; Taelman, Paul; Van Crombrugge, Paul; Van den Bruel, Annick; Velkeniers, Brigitte; Williams, Paul

    2017-07-01

    The IFCC Committee for Standardization of Thyroid Function Tests developed a global harmonization approach for thyroid-stimulating hormone measurements. It is based on a multiassay method comparison study with clinical serum samples and target setting with a robust factor analysis method. Here we describe the Phase IV method comparison and reference interval (RI) studies conducted with the objective to recalibrate the participating assays and demonstrate the proof-of-concept. Fourteen manufacturers measured the harmonization and RI panel; 4 of them quantified the harmonization and first follow-up panel in parallel. All recalibrated their assays to the statistically inferred targets. For validation, we used desirable specifications from the biological variation for the bias and total error (TE). The RI measurements were done with the assays' current calibrators, but data were also reported after transformation to the new calibration status. We estimated the pre- and postrecalibration RIs with a nonparametric bootstrap procedure. After recalibration, 14 of 15 assays met the bias specification with 95% confidence; 8 assays complied with the TE specification. The CV of the assay means for the harmonization panel was reduced from 9.5% to 4.2%. The RI study showed improved uniformity after recalibration: the ranges (i.e., maximum differences) exhibited by the assay-specific 2.5th, 50th, and 97.5th percentile estimates were reduced from 0.27, 0.89, and 2.13 mIU/L to 0.12, 0.29, and 0.77 mIU/L. We showed that harmonization increased the agreement of results from the participating immunoassays, and may allow them to adopt a more uniform RI in the future. © 2017 American Association for Clinical Chemistry.

  2. Reevaluation of the Thyroid Scan for the Assessment of Pathophysiologic Status of Thyroid Disease

    International Nuclear Information System (INIS)

    Woo, In Sook; Nah, Jung Il; Kim, Deog Yoon

    1991-01-01

    To diagnosis and understand the pathophysiologic status of thyroid disease, not only hormonal measurements but also thyroid scan is believed to have a unique role. Especially in the cases of the change of the thyroid function by thyroiditis, it is emphasized that thyroid scan can be helpful in differential diagnosis, Discordant results of thyroid hormone levels and thyroid scan are found in transient hyperthyroidism, or in transient hypothyroidism. We analysed and reevaluated thyroid scan to look at the importance of thyroid scan. The results are summarised as follows: 1) 80%. of hyperthyroid patients had hyperthyroidism increased RAIU with even density, they are compatible with Graves' disease. 2) 2.1% of hyperthyroid patients had normal or decreased RAIU, which are classified as high iodine turn over genuine hyperthyroidism. 3) 8.5% of hyperthyroid patients had markedly decreased RAIU at both 2 hour and 24 hour, whose pathologic processes are suggested to be heterogenous namely subacute thyroiditis, postpartum thyroiditis, Hashimoto's thyroiditis, and pamless thyroiditis. 4) 45% of hypothyroid patients had increased 24 hr RAIU, 30% of hypothyroid patients were normal, 25%, decreased. In conclusion, thyroid scan should be reevaluated its useful role to asses the pathophysiologic status of thyroid disease. Especially in cases of transient thyrotoxicosis, thyroid scan is essential to diagnose and follow up the disease process.

  3. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  4. Laser-induced incandescence: Towards quantitative soot volume fraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tzannis, A.P.; Wienbeucker, F.; Beaud, P.; Frey, H.-M.; Gerber, T.; Mischler, B.; Radi, P.P. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Laser-Induced Incandescence has recently emerged as a versatile tool for measuring soot volume fraction in a wide range of combustion systems. In this work we investigate the essential features of the method. LII is based on the acquisition of the incandescence of soot when heated through a high power laser pulse. Initial experiments have been performed on a model laboratory flame. The behaviour of the LII signal is studied experimentally. By applying numerical calculations we investigate the possibility to obtain two-dimensional soot volume fraction distributions. For this purpose a combination of LII with other techniques is required. This part is discussed in some extent and the future work is outlined. (author) 4 figs., 3 refs.

  5. Radioiodine therapy of thyroid autonomy

    International Nuclear Information System (INIS)

    Reiners, Christoph; Schneider, Peter

    2002-01-01

    Over half a century, treatment of thyroid autonomy with an oral dose of iodine-131 has proven to be effective. The optimum management strategy for the patient is, however, still a matter of debate. The article provides an overview of the pathogenesis of functional autonomy and its clinical relevance. According to the guidelines on both sides of the Atlantic, radioiodine treatment is considered the most comfortable and economical approach to the treatment of the toxic nodular goitre. Some differences in the preparation procedures in the guidelines of the American and the German Society of Nuclear Medicine are discussed with respect to therapy results and the subtypes of thyroid autonomy. The results of studies are summarised concerning changes in thyroid function and thyroid volume after a course of radioiodine treatment. Therapy-related risks, such as immunogenic hypothyroidism or thyroid cancer, are discussed. 131 I treatment of functional autonomy and hyperthyroidism is considered an effective and safe procedure. (orig.)

  6. Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956)- An Assessment of Quantities released, Off-Site Radiation Doses, and Potential Excess Risks of Thyroid Cancer, Volume 1

    International Nuclear Information System (INIS)

    Apostoaei, A.I.; Burns, R.E.; Hoffman, F.O.; Ijaz, T.; Lewis, C.J.; Nair, S.K.; Widner, T.E.

    1999-01-01

    In the early 1990s, concern about the Oak Ridge Reservation's past releases of contaminants to the environment prompted Tennessee's public health officials to pursue an in-depth study of potential off-site health effects at Oak Ridge. This study, the Oak Ridge dose reconstruction, was supported by an agreement between the U.S. Department of Energy (DOE) and the State of Tennessee, and was overseen by a 12-member panel appointed by Tennessee's Commissioner of Health. One of the major contaminants studied in the dose reconstruction was radioactive iodine, which was released to the air by X-10 (now called Oak Ridge National Laboratory) as it processed spent nuclear reactor fuel from 1944 through 1956. The process recovered radioactive lanthanum for use in weapons development. Iodine concentrates in the thyroid gland so health concerns include various diseases of the thyroid, such as thyroid cancer. The large report, ''Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956) - An Assessment of Quantities Released, Off-site Radiation Doses, and Potential Excess Risks of Thyroid Cancer,'' is in two volumes. Volume 1 is the main body of the report, and Volume 1A, which has the same title, consists of 22 supporting appendices. Together, these reports serve the following purposes: (1) describe the methodologies used to estimate the amount of iodine-131 (I-131) released; (2) evaluate I-131's pathway from air to vegetation to food to humans; (3) estimate doses received by human thyroids; (4) estimate excess risk of acquiring a thyroid cancer during ones lifetime; and (5) provide equations, examples of historical documents used, and tables of calculated values. Results indicate that females born in 1952 who consumed milk from a goat pastured a few miles east of X-10 received the highest doses from I-131 and would have had the highest risks of contracting thyroid cancer. Doses from cow's milk are considerably less . Detailed

  7. Challenges in interpretation of thyroid function tests in pregnant women with autoimmune thyroid disease

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Bliddal, Sofie; Rasmussen, Åse Krogh

    2011-01-01

    Physiological changes during gestation are important to be aware of in measurement and interpretation of thyroid function tests in women with autoimmune thyroid diseases. Thyroid autoimmune activity is decreasing in pregnancy. Measurement of serum TSH is the first-line screening variable...... for thyroid dysfunction also in pregnancy. However, using serum TSH for control of treatment of maternal thyroid autoimmunity infers a risk for compromised foetal development. Peripheral thyroid hormone values are highly different among laboratories, and there is a need for laboratory-specific gestational age......-related reference ranges. Equally important, the intraindividual variability of the thyroid hormone measurements is much narrower than the interindividual variation (reflecting the reference interval). The best laboratory assessment of thyroid function is a free thyroid hormone estimate combined with TSH...

  8. MR imaging of diffuse thyroid disorders

    International Nuclear Information System (INIS)

    Inoue, Masaaki; Fujii, Koichi; Ohnishi, Takuya; Higashikawa, Motoki; Araki, Yutaka; Hamada, Tatsumi; Ishida, Osamu

    1996-01-01

    Magnetic resonance imaging was performed in 38 diffuse goiters, including 30 chronic thyroiditis and 8 Basedow disease. MR findings were analyzed as to degree of swelling, margin, internal structures including homogeneity and low intensity bands. With regard to signal intensity, thyroid-muscle-signal intensity ratios on T1 and T2-weighted images were measured in 19 normal thyroid glands, 30 chronic thyroiditis and 8 Basedow disease. Additionally thyroid-muscle-signal intensity ratios were compared between 19 hypothyroid glands and 11 euthyroid glands in chronic thyroiditis. Chronic thyroiditis tended to show lobulated margins, inhomogeneous intensity, and low intensity bands connecting with vessels or not. Basedow disease tended to display smooth margins, inhomogeneous intensity and low intensity bands connecting with vessels. Thyroid-muscle-signal intensity ratios of Basedow disease and chronic thyroiditis were significantly higher than those of normal thyroid gland at all sequences. In chronic thyroiditis thyroid-muscle-signal intensity ratios of euthyroid glands were significantly higher than those of hypothyroid glands. MR imaging could reflect pathologic features of diffuse goiters. Moreover, MR imaging is potentially contributory to speculate about thyroid function and degree of serious condition in diffuse thyroid disorders. (author)

  9. Ten-year follow-up of thyroid epidemiology in Slovenia after increase in salt iodization

    Science.gov (United States)

    Zaletel, Katja; Gaberšček, Simona; Pirnat, Edvard; Krhin, Blaž; Hojker, Sergej

    2011-01-01

    Aim To assess iodine supply and follow thyroid epidemiology for ten years after an iodine increase from 10 to 25 mg of potassium iodide per kilogram of salt in 1999. Methods In 2002 and 2003, we determined the thyroid size by palpation and ultrasound and measured urinary iodine concentration (UIC) in 676 schoolchildren from 34 schools throughout Slovenia. From 1999 to 2009, we followed the incidence of diffuse and nodular goiter, thyroid autonomy, Graves’ disease, and Hashimoto’s thyroiditis among adults in the stable catchment area of the University Medical Centre Ljubljana with 1 000 000 inhabitants. Results In children, only 1% had a goiter grade 2 (visible and palpable thyroid gland), median thyroid volume was 5.8 mL, and median UIC was 148 µg/L. In adults, the incidence of diffuse goiter and thyroid autonomy decreased significantly (2009 vs 1999, rate ratio [RR], 0.16; 95% confidence interval [CI], 0.12-0.21 and RR, 0.73; 95% CI, 0.62-0.86, respectively), with a lower incidence in younger participants in 2009 (P < 0.001). The incidence of multinodular goiter and solitary nodule increased (2009 vs 1999, RR, 1.55; 95% CI, 1.35-1.79 and RR, 1.72; 95% CI, 1.49-1.99, respectively). No long-term changes were observed for Graves’ disease (2009 vs 1999, RR, 0.95; 95% CI, 0.81-1.13), while the incidence of Hashimoto’s thyroiditis increased strongly (2009 vs 1999, RR, 1.86; 95% CI, 1.64-2.12). Conclusions The change from mildly deficient to sufficient iodine supply was associated with a marked change in the incidence of thyroid epidemiology – a significant decline in the incidence of diffuse goiter and thyroid autonomy and a marked increase in the incidence of Hashimoto’s thyroiditis. PMID:21990079

  10. Measurement of {sup 131}I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital

    Energy Technology Data Exchange (ETDEWEB)

    Brudecki, K.; Mietelski, J.W. [Polish Academy of Sciences, Institute of Nuclear Physics, Krakow (Poland); Kowalska, A.; Szczodry, A. [Holy Cross Cancer Center, Department of Endocrinology and Nuclear Medicine, Kielce (Poland); Zagrodzki, P. [Polish Academy of Sciences, Institute of Nuclear Physics, Krakow (Poland); Jagiellonian University, Department of Food Chemistry and Nutrition, Medical College, Krakow (Poland); Mroz, T. [Pedagogical University in Cracow, Krakow (Poland); Janowski, P. [AGH University of Science and Technology, Krakow (Poland)

    2017-03-15

    This paper presents results of {sup 131}I thyroid activity measurements in 30 members of the nuclear medicine personnel of the Department of Endocrinology and Nuclear Medicine Holy Cross Cancer Centre in Kielce, Poland. A whole-body spectrometer equipped with two semiconductor gamma radiation detectors served as the basic research instrument. In ten out of 30 examined staff members, the determined {sup 131}I activity was found to be above the detection limit (DL = 5 Bq of {sup 131}I in the thyroid). The measured activities ranged from (5 ± 2) Bq to (217 ± 56) Bq. The highest activities in thyroids were detected for technical and cleaning personnel, whereas the lowest values were recorded for medical doctors. Having measured the activities, an attempt has been made to estimate the corresponding annual effective doses, which were found to range from 0.02 to 0.8 mSv. The highest annual equivalent doses have been found for thyroid, ranging from 0.4 to 15.4 mSv, detected for a cleaner and a technician, respectively. The maximum estimated effective dose corresponds to 32% of the annual background dose in Poland, and to circa 4% of the annual limit for the effective dose due to occupational exposure of 20 mSv per year, which is in compliance with the value recommended by the International Commission on Radiological Protection. (orig.)

  11. Thyroid uptake measurements: gamma camera system with Pinhole collimator and nuclear medicine system model 13S002; Medida da captacao de Iodo pela tiroide: sistema gama-camara com colimador Pinhole x Sistema 13S002

    Energy Technology Data Exchange (ETDEWEB)

    Silva, C.B. [Instituto de Engenharia Nuclear (IEN), Rio de Janeiro, RJ (Brazil); Corbo, R.; Rebelo, A.M. [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil); Karam, R. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil)]. E-mail: borges@ien.gov.br

    2001-07-01

    The thyroid uptake measurements are common in medical uses and are considered a direct and precise form of diagnostic, however, different results have been observed as measurements of thyroid uptake are taken using distinct equipment. This study attempts to find the cause of the differences between a thyroid uptake probe and a gamma camera. These discrepancies can be associated to the different patients samples, equipment's problems or operator procedures errors. This work presents the results of comparative uptake measurements performed in a neck phantom and a 4-hour thyroid uptake study in 40 patients, using a Gamma Camera Ohio Nuclear model Sigma 410 with a pinhole collimator and Nuclear Medicine System model 13S002, developed by Instituto de Engenharia Nuclear. The results observed show that in spite of non satisfactory results commented in literature, both the System 13S002 and System Gamma Camera Ohio can be used in uptake thyroid diagnostic with statistical confidence degree of 99 %. (author)

  12. Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair.

    NARCIS (Netherlands)

    Keulen, J.W. van; Prehn, J. van; Prokop, M.; Moll, F.L.; Herwaarden, J.A. van

    2009-01-01

    PURPOSE:To investigate the value of aneurysm sac volume measurement in addition to diameter measurements based on computed tomographic angiography (CTA) after endovascular aneurysm repair (EVAR). METHODS:Interrogation of a vascular database identified 56 patients (51 men; median age 77 years, range

  13. Thyroid diseases

    International Nuclear Information System (INIS)

    Noma, Koji

    1992-01-01

    This chapter reviews the correlation between thyroid disease, other than cancer, and radiation in the literature. Radiation-induced thyroid disturbance is discussed in the context of external and internal irradiation. External irradiation of 10 to 40 Gy may lower thyroid function several months or years later. Oral administration of I-131 is widely given to patients with Basedow's disease; it may also lower thyroid function with increasing radiation doses. When giving 70 Gy or more of I-131, hypothyroidism has been reported to occur in 20-30% and at least 10%. Thyroiditis induced with internal I-131 irradiation has also been reported, but no data is available concerning external irradiation-induced thyroiditis. The incidence of nodular goiter was found to be several ten times higher with external irradiation than internal irradiation. Thyroid disturbance is correlated with A-bomb survivors. A-bomb radiation can be divided into early radiation within one minute after A-bombing and the subsequent residual radiation. Nodular goiter was significantly more frequent in the exposed group than the non-exposed group; it increased with increasing radiation doses and younger age (20 years or less) at the time of exposure. The incidence of decrease in thyroid function was higher with increasing radiation doses. However, in the case of Nagasaki, the incidence of hypothyroidism was significantly higher in the low-dose exposed group, especially A-bomb survivors aged 10-39 at the time of exposure and women. (N.K.)

  14. Measurement of fiber bundle volume in reprocessed dialyzers.

    Science.gov (United States)

    Narsipur, S S

    2004-02-01

    Fiber bundle volume (FBV) is an important determinant of dialyzer re-use efficiency. This measurement is performed after the dialyzer has been pressure cleaned and may underestimate the degree of clotted fibers a patient actually encounters while on dialysis. Real-time online measure of FBV has been validated using an ultrasound dilution method and the Transonic HD01 monitor (Ithaca, NY, USA). Thirty-one stable chronic hemodialysis patients were studied during the first hour and then during the last 30 minutes of a typical dialysis session. Ultrasound velocity curves using a saline bolus were recorded by flow dilution sensors placed directly on the blood tubing using methods described previously. Blood volume within the dialyzer compartment was determined using a mathematical extrapolation of the measured transit time for a bolus of saline to pass through the dialyzer. These data were compared to FBV obtained using a Seartronics DRS4 (Fresinius, Walnut Creek, CA, USA) reprocessing machine both before and after the same dialysis session. At onset of treatment mean FBV by ultrasound was 100.0 +/- 2.7 ml and was unchanged at the end of the session at 100.0 +/- 3.1 ml (p = 0.49). Before a dialysis session, mean FBV measured on the DRS4 reprocessing machine was 123.5 +/- 2.1 ml and was unchanged following cleaning after dialysis at 121.7 +/- 2.0 ml (p = 0.20). The correlation coefficient between methods was 0.78. FBV did not change during a dialysis session using an online real-time measure. The results of this study do not support concerns that hemodialysis patients may experience considerably less efficient dialysis than standard FBV determination would suggest due to undetected clotting.

  15. External dose measurements for patients receiving therapeutic I-131 for thyroid cancer

    International Nuclear Information System (INIS)

    Molfetas, M.; Kottou, S.

    2002-01-01

    Iodine-131 is a well established and effective treatment, supplementing surgery, in differentiated thyroid carcinoma. Iodine-131 except from its β-emission, that generates a cell-killing effect in a small area, has also a γ-emission irradiating distant tissues and even people who are close enough with the treated patient. The International Commission on Radiation Protection, ICRP has estimated the probability of a radiation-induced fatal cancer for the whole population at 5.0 % per sievert for low doses and at low dose rates and at 1.3 % for serious genetic diseases. For elderly people the probability seems to be 3 to 10 times lower, whereas for children up to the age of 10 years, 2-3 times higher. These findings led the ICRP to recommend new dose limits, lower than the previous ones. The European Union has endorsed the ICRP recommendations and the Council issued two directives, with which the Greek legislation complied recently. The current annual public dose limit is 1 mSv, while in the new Greek legislation the concept of dose constrains (0.5 m Sv in Greece) has also been proposed as a goal to reach whenever possible

  16. Thyroid size and thyroid function during pregnancy: an analysis

    NARCIS (Netherlands)

    Berghout, A.; Wiersinga, W.

    1998-01-01

    An analysis of all available studies of thyroid size and function in pregnancy reveals that thyroid size, estimated by inspection and palpation or measured more accurately by ultrasonography, increases in pregnancy in areas of iodine deficiency but not in those with sufficient iodine. The increase

  17. Evaluation of right ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Stubgaard, M; Thomsen, C

    1988-01-01

    Right ventricular volumes were determined in 12 patients with different levels of right and left ventricular function by magnetic resonance imaging (MRI) using an ECG gated multisection technique in planes perpendicular to the diastolic position of the interventricular septum. Right ventricular...... stroke volume was calculated as the difference between end-diastolic and end-systolic volume and compared to left ventricular stroke volume and to stroke volume determined simultaneously by a classical indicator dilution technique. There was good agreement between right ventricular stroke volume...... determined by MRI and by the indicator dilution method and between right and left ventricular stroke volume determined by MRI. Thus, MRI gives reliable values not only for left ventricular volumes, but also for right ventricular volumes. By MRI it is possible to obtain volumes from both ventricles...

  18. Benign solitary solid cold thyroid nodules

    DEFF Research Database (Denmark)

    Døssing, Helle; Bennedbaek, Finn Noe; Karstrup, Steen

    2002-01-01

    PURPOSE: To evaluate the effects of ultrasonography (US)-guided interstitial laser photocoagulation (ILP) on the volume of benign solitary solid cold thyroid nodules and any nodule-related symptoms. MATERIALS AND METHODS: ILP was performed in 16 patients with normal thyroid function and a solid...... benign thyroid nodule. None of the patients had uptake on a radionuclide scan. Patients underwent one ILP session. A needle was positioned in the thyroid nodule with US guidance, and the laser fiber was placed in the lumen of the needle. Patients were treated for 287-1,200 seconds with an output power...... of 1-3 W. ILP was performed with continuous US guidance and terminated when the echogenic changes were stationary. Thyroid nodule volume and thyroid function were evaluated before and 1, 3, and 6 months after treatment. During the same period, 15 untreated patients (control group) were followed up...

  19. Recommendations for the measurement 131I in human thyroid using a detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Puerta Yepes, N.; Rojo, A.M.; Andres, P.A.

    2010-01-01

    The Argentine Total Body Counter Laboratory of the Nuclear Regulatory Authority participated in the last regional intercomparison Exercise organized in the frame of the IAEA Project RLA 9/066 related with in vivo measurements of 131 I in the thyroid. There were identified some difficulties in determining the efficiency and calibration factor (CF) for the 131 I when a source of 133 Ba and a detector of NaI (Tl) are used in the calibration process. Independent measurements were performed for two calibration sources of known activity ( 133 Ba and 131 I) with identical geometry pattern and using a gamma spectrometry system with NaI(Ti) detector. It was found that the region of interest (ROI) which, both in the spectrum of 133 Ba as in the spectrum of 131 I, had the same efficiency. It was determined the activity of the source of 133 Ba , distributed in the intercomparison, and the calibrated source of 131 I using different values of efficiency and FC obtained. It was analyzed the conditions under which the use of 133 Ba as a source of calibration is effective for the measurement of 131 I. (authors) [es

  20. Thyroid effects

    International Nuclear Information System (INIS)

    Maxon, H.; Thomas, S.; Buncher, C.; Book, S.; Hertzberg, V.

    1985-01-01

    Risk coefficients for thyroid disorders have been developed for both 131 I and external x or gamma low-LET radiation. A linear, no-threshold model has been used for thyroid neoplasms. A linear, threshold model has been used for other thyroid disorders. Improvements since the Reactor Safety Study were made possible by relevant new animal and human data. Major changes are as follows. Animal data are used to supplement the human experience where necessary. A specific risk estimate model is used for thyroid neoplasms, which accounts for observed effects of gender and age at exposure on risk. For thyroid cancer, the basis of the risk coefficients is the experience of North Americans following x-irradiation for benign disease in childhood. This recognizes possible differences in susceptibility in people of different heritage. A minimum induction period for thyroid neoplasms following irradiation is used to define periods at risk. An upper bound risk coefficient for cancer induction following exposure to 131 I is based on human experience at relatively low dose exposures. While the overall lifetime risks of death due to thyroid cancer are consistent with projections by the ICRP, BEIR III, and UNSCEAR Reports, the current model permits greater flexibility in determining risk for population subgroups. 88 references, 8 tables

  1. Long-term efficacy of current thyroid prophylaxis and future perspectives on thyroid protection during I-131-metaiodobenzylguanidine treatment in children with neuroblastoma

    NARCIS (Netherlands)

    Clement, S. C.; van Rijn, R. R.; van Eck-Smit, B. L. F.; van Trotsenburg, A. S. P.; Caron, H. N.; Tytgat, G. A. M.; van Santen, H. M.

    2015-01-01

    Purpose Treatment with I-131-MIBG is associated with significant thyroid damage. This study was undertaken to investigate the long-term efficacy of current thyroid prophylaxis, to explore the relationship between thyroid dysfunction and thyroid volume after exposure to I-131-MIBG and to evaluate the

  2. Long-term efficacy of current thyroid prophylaxis and future perspectives on thyroid protection during I-131-metaiodobenzylguanidine treatment in children with neuroblastoma

    NARCIS (Netherlands)

    Clement, S. C.; van Rijn, R. R.; van Eck-Smit, B. L. E.; van Trotsenburg, A. S. P.; Caron, H. N.; Tytgat, G. A. M.; van Santen, H. M.|info:eu-repo/dai/nl/238668959

    Purpose Treatment with I-131-MIBG is associated with significant thyroid damage. This study was undertaken to investigate the long-term efficacy of current thyroid prophylaxis, to explore the relationship between thyroid dysfunction and thyroid volume after exposure to I-131-MIBG and to evaluate the

  3. Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.

    Science.gov (United States)

    Esquinas, Pedro L; Tanguay, Jesse; Gonzalez, Marjorie; Vuckovic, Milan; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O; Celler, Anna

    2016-12-01

    In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the current is converted into units of activity by applying an appropriate calibration factor (also referred to as DC dial setting). Accurate determination of DC dial settings is crucial to ensure that patients receive the appropriate dose in diagnostic scans or radionuclide therapies. The goals of this study were (1) to describe a practical method to experimentally determine dose calibrator settings using a thyroid-probe (TP) and (2) to investigate the accuracy, reproducibility, and uncertainties of the method. As an illustration, the TP method was applied to determine 188 Re dial settings for two dose calibrator models: Atomlab 100plus and Capintec CRC-55tR. Using the TP to determine dose calibrator settings involved three measurements. First, the energy-dependent efficiency of the TP was determined from energy spectra measurements of two calibration sources ( 152 Eu and 22 Na). Second, the gamma emissions from the investigated isotope ( 188 Re) were measured using the TP and its activity was determined using γ-ray spectroscopy methods. Ambient background, scatter, and source-geometry corrections were applied during the efficiency and activity determination steps. Third, the TP-based 188 Re activity was used to determine the dose calibrator settings following the calibration curve method [B. E. Zimmerman et al., J. Nucl. Med. 40, 1508-1516 (1999)]. The interobserver reproducibility of TP measurements was determined by the coefficient of variation (COV) and uncertainties associated to each step of the measuring process were estimated. The accuracy of activity measurements using the proposed method was evaluated by comparing the TP activity estimates of 99m Tc

  4. 21 CFR 862.1690 - Thyroid stimulating hormone test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Thyroid stimulating hormone test system. 862.1690... Systems § 862.1690 Thyroid stimulating hormone test system. (a) Identification. A thyroid stimulating hormone test system is a device intended to measure thyroid stimulating hormone, also known as...

  5. Thyroid nodule prevalence and radiation dose from fallout near the Semipalatinsk test site in Kazakhstan

    International Nuclear Information System (INIS)

    Land, C.E.; Luckyanov, N.K.; Simon, S.L.; Zhumadilov, Z.; Gusev, B.I.; Hartshorne, M.N.; Carr, Z.A.

    2003-01-01

    Thyroid nodule prevalence was use as a biomarker for radiation-related thyroid cancer risk associated with dose from internal and external radiation sources in fallout from the Semipalatinsk Test Site (STS) in Kazakhstan. Ultrasound scans were done on the thyroid glands of 1990 current residents of 7 villages near the STS, all members of a defined study cohort established in the 1960s, and all juveniles at some time during 1949-1962. Questionnaire-guided interviews focused on residential history and childhood consumption of milk and milk products. A refined dose reconstruction algorithm, developed jointly by experts from Russia and the US, was applied to the resulting data to calculate individual estimates of thyroid dose from external and internal sources of fallout-related radiation. Individual radiation dose estimates ranged from zero to 20 Gy for total dose (0-1.7 Gy and 0-20 Gy for dose from external and internal sources, respectively). The ratio of internal to external dose generally increased with increasing distance, reflecting a shift towards smaller particle sizes at greater distances and more effective transfer of small particles through the foodchain. Dose-response analysis was focused on variation of nodule prevalence by sex, age at screening, measured thyroid volume, and reconstructed thyroid dose from external (mainly gamma-ray) and internal (mainly 131 I) radiation sources. Nodule prevalence was markedly higher among women and increased significantly with increasing age at screening and with thyroid volume. Highly significant dose responses were observed for nodule prevalence as a function of total thyroid dose and, in a separate analysis, of doses from internal and external sources as distinct independent variables; dose response was linear for total dose 131 I cf. x ray with respect to thyroid cancer as an endpoint, based on theoretical, experimental, and epidemiological data

  6. Prevalence and Characterization of Thyroid Hemiagenesis in Japan: The Fukushima Health Management Survey.

    Science.gov (United States)

    Suzuki, Satoru; Midorikawa, Sanae; Matsuzuka, Takashi; Fukushima, Toshihiko; Ito, Yuko; Shimura, Hiroki; Takahashi, Hideto; Ohira, Tetsuya; Ohtsuru, Akira; Abe, Masafumi; Suzuki, Shinichi; Yamashita, Shunichi

    2017-08-01

    Thyroid hemiagenesis is a rare congenital variant characterized by the lack of development of one thyroid lobe with no clinical manifestations. This study was performed to determine the prevalence and characteristics of thyroid hemiagenesis in a normal Japanese population. This cross-sectional study was performed from October 9, 2011, to April 30, 2015. In total, 299,908 children and young adults in the Fukushima Health Management Survey were examined to determine the presence of thyroid agenesis or hemiagenesis. Thyroid width, thickness, and length were measured in 292,452 of these subjects. Thyroid agenesis was diagnosed in 13 subjects, and hemiagenesis was detected in 67 subjects (0.02%; 22.3/100,000 individuals). Although there was no significant sex-related difference (p = 0.067), the female:male ratio was 1.67:1.00. Females were significantly dominant in right hemiagenesis, while there was no difference in left hemiagenesis between males and females. The thyroid volumes at the 2.5th and 97.5th percentiles for age and body surface area were determined for each sex. Multivariate regression analysis showed that a large hemithyroid volume was independently associated with the presence of contralateral hemiagenesis (p < 0.001). The prevalence of thyroid hemiagenesis in the present study is in agreement with that reported in other countries. The prevalence of right hemiagenesis was higher in females, and the larger contralateral lobe in patients with rather than without hemiagenesis may have been caused by a compensatory feedback mechanism to prevent hypothyroidism. In addition, the prevalence of hemiagenesis, especially right hemiagenesis, may be affected by sex-related factors similar to those in patients with an ectopic thyroid gland.

  7. Thyroid Function Tests

    Science.gov (United States)

    ... hyperthyroid patient, the most likely diagnosis is autoimmune thyroid disease. THYROGLOBULIN Thyroglobulin (Tg) is a protein produced by ... Anaplastic Thyroid Cancer Complementary and Alternative Medicine in Thyroid Disease FNA Biopsy of Thyroid Nodules Goiter Graves’ Disease ...

  8. Chronic thyroiditis (Hashimoto disease)

    Science.gov (United States)

    ... common in people with a family history of thyroid disease. In very rare cases, the disease may be ... syndrome - Hashimoto; PGA II - Hashimoto Images Endocrine glands Thyroid enlargement - scintiscan Hashimoto's disease (chronic thyroiditis) Thyroid gland References Amino N, Lazarus ...

  9. Pediatric Thyroid Cancer

    Science.gov (United States)

    ... Find an ENT Doctor Near You Pediatric Thyroid Cancer Pediatric Thyroid Cancer Patient Health Information News media interested in ... and neck issues, should be consulted. Types of thyroid cancer in children: Papillary : This form of thyroid cancer ...

  10. Thyroid cancer - medullary carcinoma

    Science.gov (United States)

    Thyroid - medullary carcinoma; Cancer - thyroid (medullary carcinoma); MTC; Thyroid nodule - medullary ... National Cancer Institute. PDQ thyroid cancer treatment. Bethesda, ... February 4, 2016. www.cancer.gov/cancertopics/pdq/treatment/ ...

  11. Thyroid dysfunction in Down's syndrome and screening for hypothyroidism in children and adolescents using capillary TSH measurement.

    LENUS (Irish Health Repository)

    Murphy, J

    2008-02-01

    Thyroid dysfunction is more common in individuals with Down\\'s syndrome (DS) than in the general population, whose clinical features can mask the presenting signs and symptoms of hypothyroidism. Biochemical screening is necessary; however, venepuncture may be difficult.

  12. Radioiodine and thyroid gland

    OpenAIRE

    Takavar A

    1994-01-01

    Administration of a precise amount of activity in thyroid gland radioiodine (¹³¹I) therapy is of prime importance. Several methods for this purpose have been suggested and used over many years. In this paper, a method for required ¹³¹I activity calculation for each case has been proposed. Major factors affecting ¹³¹I calculation such as gland volume, integral dose, and prescription index have been described. Usin...

  13. A predictive mathematical model for the calculation of the final mass of Graves' disease thyroids treated with 131I

    Science.gov (United States)

    Traino, Antonio C.; Di Martino, Fabio; Grosso, Mariano; Monzani, Fabio; Dardano, Angela; Caraccio, Nadia; Mariani, Giuliano; Lazzeri, Mauro

    2005-05-01

    Substantial reductions in thyroid volume (up to 70-80%) after radioiodine therapy of Graves' hyperthyroidism are common and have been reported in the literature. A relationship between thyroid volume reduction and outcome of 131I therapy of Graves' disease has been reported by some authors. This important result could be used to decide individually the optimal radioiodine activity A0 (MBq) to administer to the patient, but a predictive model relating the change in gland volume to A0 is required. Recently, a mathematical model of thyroid mass reduction during the clearance phase (30-35 days) after 131I administration to patients with Graves' disease has been published and used as the basis for prescribing the therapeutic thyroid absorbed dose. It is well known that the thyroid volume reduction goes on until 1 year after therapy. In this paper, a mathematical model to predict the final mass of Graves' diseased thyroids submitted to 131I therapy is presented. This model represents a tentative explanation of what occurs macroscopically after the end of the clearance phase of radioiodine in the gland (the so-called second-order effects). It is shown that the final thyroid mass depends on its basal mass, on the radiation dose absorbed by the gland and on a constant value α typical of thyroid tissue. α has been evaluated based on a set of measurements made in 15 reference patients affected by Graves' disease and submitted to 131I therapy. A predictive equation for the calculation of the final mass of thyroid is presented. It is based on macroscopic parameters measurable after a diagnostic 131I capsule administration (0.37-1.85 MBq), before giving the therapy. The final mass calculated using this equation is compared to the final mass of thyroid measured 1 year after therapy administration in 22 Graves' diseased patients. The final masses calculated and measured 1 year after therapy are in fairly good agreement (R = 0.81). The possibility, for the physician, to decide a

  14. A predictive mathematical model for the calculation of the final mass of Graves' disease thyroids treated with 131I

    International Nuclear Information System (INIS)

    Traino, Antonio C; Martino, Fabio Di; Grosso, Mariano; Monzani, Fabio; Dardano, Angela; Caraccio, Nadia; Mariani, Giuliano; Lazzeri, Mauro

    2005-01-01

    Substantial reductions in thyroid volume (up to 70-80%) after radioiodine therapy of Graves' hyperthyroidism are common and have been reported in the literature. A relationship between thyroid volume reduction and outcome of 131 I therapy of Graves' disease has been reported by some authors. This important result could be used to decide individually the optimal radioiodine activity A 0 (MBq) to administer to the patient, but a predictive model relating the change in gland volume to A 0 is required. Recently, a mathematical model of thyroid mass reduction during the clearance phase (30-35 days) after 131 I administration to patients with Graves' disease has been published and used as the basis for prescribing the therapeutic thyroid absorbed dose. It is well known that the thyroid volume reduction goes on until 1 year after therapy. In this paper, a mathematical model to predict the final mass of Graves' diseased thyroids submitted to 131 I therapy is presented. This model represents a tentative explanation of what occurs macroscopically after the end of the clearance phase of radioiodine in the gland (the so-called second-order effects). It is shown that the final thyroid mass depends on its basal mass, on the radiation dose absorbed by the gland and on a constant value α typical of thyroid tissue. α has been evaluated based on a set of measurements made in 15 reference patients affected by Graves' disease and submitted to 131 I therapy. A predictive equation for the calculation of the final mass of thyroid is presented. It is based on macroscopic parameters measurable after a diagnostic 131 I capsule administration (0.37-1.85 MBq), before giving the therapy. The final mass calculated using this equation is compared to the final mass of thyroid measured 1 year after therapy administration in 22 Graves' diseased patients. The final masses calculated and measured 1 year after therapy are in fairly good agreement (R = 0.81). The possibility, for the physician, to

  15. Thyroid gland removal

    Science.gov (United States)

    Total thyroidectomy; Partial thyroidectomy; Thyroidectomy; Subtotal thyroidectomy; Thyroid cancer - thyroidectomy; Papillary cancer - thyroidectomy; Goiter - thyroidectomy; Thyroid nodules - thyroidectomy

  16. Correlation between magnetic resonance imaging and ultrasound measurements of eye muscle thickness in thyroid-associated orbitopathy.

    Science.gov (United States)

    Karhanova, Marta; Kovar, Radim; Frysak, Zdenek; Sin, Martin; Zapletalova, Jana; Rehak, Jiri; Herman, Miroslav

    2015-06-01

    To compare ultrasound (US) and magnetic resonance imaging (MRI) measurements of horizontal eye muscle thickness in patients with thyroid-associated orbitopathy (TAO) and to compare these measurements according to the phase of the disease, the severity of exophthalmos, and the experience of the investigator. A total of 180 orbits of adult patients with TAO were investigated from May 2007 to December 2012. In addition to their general ophthalmic examination, all patients underwent ultrasonographic measurement of horizontal eye muscle thickness with the B-scan technique and MRI examination of the orbit. Correlations between values obtained by US and MRI were determined for different subgroups according to disease activity (active, inactive), exophthalmos values (Hertel 22 mm), and the time period of examination (2007-2009; 2010-2012). Positive moderate correlation between US and MRI values for the medial rectus muscle (MRM; r = 0.690) and for the lateral rectus muscle (LRM; r = 0.572) was found. Significantly higher correlation was found for the MRM (P < 0.0001) and the LRM (P = 0.0008) in the time period 2010-2012 than in that of 2007-2009. Increasing correlation was found for MRM with increasing values of exophthalmos but this increase was not statistically significant. In the active phase of the disease compared to the inactive phase, statistically significant increased correlation (P = 0.019) was found for the LRM. Ultrasonographic measurement of horizontal eye muscles thickness in TAO moderately correlates with values obtained using MRI. The accuracy of ultrasonographic measurements in particular increases with the experience of the investigator.

  17. Thyroglobulin (Tg) recovery testing with quantitative Tg antibody measurement for determining interference in serum Tg assays in differentiated thyroid carcinoma.

    Science.gov (United States)

    Persoon, Adrienne C M; Links, Thera P; Wilde, Juergen; Sluiter, Wim J; Wolffenbuttel, Bruce H R; van den Ouweland, Johannes M W

    2006-06-01

    Thyroglobulin (Tg) measurements are complicated by interference from Tg autoantibodies (TgAbs) or heterophilic antibodies (HAMAs). We used a new automated immunochemiluminometric assay (ICMA) with Tg recovery (TgR) on the Nichols Advantage platform to reassess the clinical utility of recovery testing in detecting interference in serum Tg measurement in patients with differentiated thyroid carcinoma. We used 2 TgAb methods to detect Tg measurement interference with TgR and quantitative TgAb measurement in sera from 127 patients. In a limited number of samples, we used an RIA as comparison method because it appeared to be minimally affected by TgAb. Prevalence of TgAbs was 13% (17 of 127) in either 1 or both TgAb assays. A compromised TgR ( or =70%) corresponded with TgAb negativity in both assays for 95 of 101 samples (94%). In 6 TgAb-positive sera with TgR within the reference interval, there were no discrepancies between RIA and ICMA results. We obtained discordant RIA and ICMA results for 6 of 9 TgAb-positive sera with decreased TgR. In 1 TgAb-negative sample, the Tg result was falsely increased because of interference by HAMAs, as shown by an overrecovery of 126%. The Nichols Advantage TgR assay is a valuable complementary method to overcome the technical problem of interference by TgAbs or HAMAs in TgAb assays. Further studies are needed to confirm the potential added value of this TgR assay.

  18. Thyroid-associated Ophthalmopathy

    Directory of Open Access Journals (Sweden)

    Esra Şahlı

    2017-03-01

    Full Text Available Thyroid-associated ophthalmopathy is the most frequent extrathyroidal involvement of Graves’ disease but it sometimes occurs in euthyroid or hypothyroid patients. Thyroid-associated ophthalmopathy is an autoimmune disorder, but its pathogenesis is not completely understood. Autoimmunity against putative antigens shared by the thyroid and the orbit plays a role in the pathogenesis of disease. There is an increased volume of extraocular muscles, orbital connective and adipose tissues. Clinical findings of thyroid-associated ophthalmopathy are soft tissue involvement, eyelid retraction, proptosis, compressive optic neuropathy, and restrictive myopathy. To assess the activity of the ophthalmopathy and response to treatment, clinical activity score, which includes manifestations reflecting inflammatory changes, can be used. Supportive approaches can control symptoms and signs in mild cases. In severe active disease, systemic steroid and/or orbital radiotherapy are the main treatments. In inactive disease with proptosis, orbital decompression can be preferred. Miscellaneous treatments such as immunosuppressive drugs, somatostatin analogs, plasmapheresis, intravenous immunoglobulins and anticytokine therapies have been used in patients who are resistant to conventional treatments. Rehabilitative surgeries are often needed after treatment.

  19. MRI-based three-dimensional thermal physiological characterization of thyroid gland of human body.

    Science.gov (United States)

    Jin, Chao; He, Zhi Zhu; Yang, Yang; Liu, Jing

    2014-01-01

    This article is dedicated to present a MRI (magnetic resonance imaging) based three-dimensional finite element modeling on the thermal manifestations relating to the pathophysiology of thyroid gland. An efficient approach for identifying the metabolic dysfunctions of thyroid has also been demonstrated through tracking the localized non-uniform thermal distribution or enhanced dynamic imaging. The temperature features over the skin surface and thyroid domain have been characterized using the numerical simulation and experimental measurement which will help better interpret the thermal physiological mechanisms of the thyroid under steady-state or water-cooling condition. Further, parametric simulations on the hypermetabolism symptoms of hyperthyroidism and thermal effects within thyroid domain caused by varying breathing airflow in the trachea and blood-flow in artery and vein were performed. It was disclosed that among all the parameters, the airflow volume has the largest effect on the total heat flux of thyroid surface. However, thermal contributions caused by varying the breathing frequency and blood-flow velocity are negligibly small. The present study suggests a generalized way for simulating the close to reality physiological behavior or process of human thyroid, which is of significance for disease diagnosis and treatment planning. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Determination of a normogram for testicular volume measured by ...

    African Journals Online (AJOL)

    4.67years, 1.18±0.29m, 24.79±14.76kg and 15.82±2.63kg/m2. The mean testicular volume in the study population was 1.93±3.31ml. The right and left mean testicular volume were 2.27±+3.66ml and 2.23±3.61ml, respectively. Testicular volume ...

  1. Dose-volume analysis of hypothyroidism in patients irradiated to the neck

    International Nuclear Information System (INIS)

    Te, Vuong; Liu, Mitchell C.C.; Parker, William; Curtin-Savard, Arthur J.; Clark, Brenda

    1997-01-01

    Purpose: To determine if the incidence of hypothyroidism in patients who have received radiation therapy to the neck region has any relationship with the total dose to the thyroid and volume of thyroid irradiation. Methods and Materials: From 1988 to 1996, TSH levels were measured at regular intervals of every 3 to 6 months in 528 patients with head and neck cancers or lymphomas (Hodgkin and non-Hodgkin) who had received radiation therapy to the neck region. Hypothyroidism was defined by TSH of ≥ 5 (normal range: 0.5 - 4mU/L). Medical charts, radiotherapy charts, treatment planning films, dosimetry and CT scans/MRI were reviewed. Thyroid volume was determined utilizing treatment planning films and CT scans/MRI. Four hundred and six patients had normal TSH prior to radiation and sufficient information to be eligible for analysis. There were 264 (65%) male and 142 (35%) female, median age was 59 yr (range: 12 - 85). Median follow-up was 39.5 months (range: 1 - 289 months). Results: Out of the 406 eligible patients, 152 (37%) had developed hypothyroidism. The actuarial incidence of hypothyroidism at 1 yr, 3 yr and 5 yr are 9.1%, 29% and 38.5%, respectively. Analysis of volume effect and dose effect are as follows: When the radiation dose to the thyroid and the volume of thyroid irradiated are analyzed together, the group of patients who received ≥ 60Gy to half of thyroid or received ≥ 30Gy to the whole thyroid has increased risk of developing hypothyroidism as compared to those receiving <60Gy to half the thyroid or <30Gy to the whole thyroid (p=.0001). Conclusions: The actuarial incidence of hypothyroidism at 5 year in patients who had received radiation to the neck is 38.5%. Patients who received ≥ 60Gy to half the thyroid or received ≥ 30Gy to the whole thyroid are at higher risk of developing hyperthyroidism

  2. Evaluation of parenchymal thyroid diseases with multiparametric ultrasonography

    Directory of Open Access Journals (Sweden)

    Duzgun Yildirim

    2017-01-01

    Full Text Available Aim: Differential diagnosis of parenchymal thyroid diseases by gray-scale ultrasound is quite difficult for a radiologist as the findings are very similar to each other. In this study we aimed to assess some quantitative spectral Doppler parameters, resistivity index (RI, acceleration time (AT, and quantitative elastography [shear wave velocity (SWV] together to show their reliability for differential diagnosis of parenchymal thyroid diseases. Materials and Methods: We retrospectively reviewed findings of 227 patients (179 females, 48 males that underwent spectral Doppler ultrasound and acoustic radiation force impulse between October 2013 and March 2016. Ages of the patients were between 18 and 74 years (39.52 ± 12.67. Based on clinical and laboratory findings, patients were divided into five groups (N: Normal, EH: Early Hashimoto, H: Late Hashimoto, M: Nodular Thyroid Disease, HM: Hashimoto + Nodular Thyroid Disease. Detailed statistical analyses were done on parameters such as age, gender, volume information, and RI, AT (ms, SWV (m/s. Results: No significant effect of gender or volume on the differentiation of disease pattern (Chi-square test: P= 0.306, Kruskal-Wallis test: P= 0.290 was found in this study. RI (0.41 ± 0.06 and SWV values (1.19 ± 0.18 m/s were the lowest. AT values (>55 ms were the highest in EH group (area under the curve: 0.913. Existence of H decreased RI and SWV values, while it extended AT in a different thyroid disease. Conclusion: Thyroid parenchymal diseases could be classified and differentiated from each other by measuring RI, AT, and SWV values quantitatively. So, in suspicious cases, these parameters could be a reliable asset for differential diagnosis.

  3. 131I-induced changes in rat thyroid gland function

    Directory of Open Access Journals (Sweden)

    V. Torlak

    2007-08-01

    Full Text Available Therapeutic doses of 131I administered to thyrotoxic patients may cause thyroid failure. The present study used a rat model to determine thyroid function after the administration of different doses of 131I (64-277 µCi. Thirty male Fisher rats in the experimental group and 30 in the control group (untreated were followed for 6 months. The animals were 4 months old at the beginning of the experiment and were sacrificed at an age of 9 months. Hormone concentration was determined before 131I administration (4-month-old animals and three times following 131I administration, when the animals were 7, 8, and 9 months old. The thyroid glands were removed and weighed, their volume was determined and histopathological examination was performed at the end of the experiment. Significant differences in serum triiodothyronine and thyroid-stimulating hormone concentration, measured at the age of 7, 8, and 9 months, were found in the experimental group. During aging of the animals, the concentration of thyroxin fell from 64.8 ± 8.16 to 55.0 ± 6.1 nM in the control group and from 69.4 ± 6.9 to 25.4 ± 3.2 nM in the experimental group. Thyroid gland volume and weight were significantly lower in the experimental than in the control group. Thyroid glands from the experimental group showed hyaline thickness of the blood vessel wall, necrotic follicles, a strong inflammatory reaction, and peeling of necrotic cells in the follicles. In conclusion, significant differences in hormone levels and histopathological findings indicated prolonged hypothyroidism after 131I administration to rats, which was not 131I dose dependent.

  4. Evaluation of pharyngeal volume and compliance of OSAHS patients using 3D CT and volume measurement

    International Nuclear Information System (INIS)

    Lan, Zhijie

    2004-01-01

    The intrinsic properties such as baseline caliber and compliance of the upper airway are thought to be important in the pathogenesis of obstructive sleep apnea hypopnea syndrome (OSAHS).The author attempted using imaging methods to evaluate both baseline caliber and compliance in normal individuals and OSAHS patients, and to localize the obstructive sites in OSAHS patients. Critical closing pressure (P crit ) and minimally effective therapeutical pressure (P eff ) were measured and computed tomography (CT) scan of pharynx was performed during wakefulness and drug-induced sleep with P crit , 0 cm H 2 O and P eff being given through a nose mask system. 7 normal individuals (age, 32.2±6.5 y's and body mass index, 23.6±5.4 kg/m 2 ) and 13 OSAHS patients (age, 33.3±6.4 y's and body mass index, 25.9±6.0 kg/m 2 ) were studied. 3D images of pharyngeal airway were reconstructed, and volume of each subdivision of pharynx was measured. Volume, average area and compliance of each subdivision were compared between the two groups. On an air-mode view of 3D image, the outline of pharynx was shown as transparent tubal structure, on which the narrowing collapse of airway at any level or any direction can be easily identified. Anatomy of pharynx could be easily understood on the virtual endoscopic mode. During wakefulness, the average area of the upper (1.20±0.26 cm 2 vs. 1.57±0.17 cm 2 , P 2 vs. 2.58±0.27 cm 2 , P 2 vs. 1.45±0.18 cm 2 , P 2 vs. 2.44±0.26 cm 2 ). The compliance of the middle part (0.28±0.15/cmH 2 O vs. 0.13±0.07/cmH 2 O, P<0.05) of pharynx was significantly higher in OSAHS patients than in normal individuals. The data suggested that OSAHS patients have a narrower and more collapsible pharynx compared to the normal subjects. The method of the present study is valid to evaluate both morphology and function of the upper airway. (author)

  5. Tomographic imaging of the human thyroid using 124I

    International Nuclear Information System (INIS)

    Frey, P.; Townsend, D.; Flattet, A.

    1986-01-01

    After receiving between 100 and 300 mu Ci of the positron-emitting radioisotope 124 I (half-life, 4.2 days), 64 patients with a variety of thyroid disorders were imaged with a high resolution positron camera. A 3-dimensional image of the distribution of radi,iodine uptake within the thyroid was obtained from a single 10- to 15-min scan. This image may be viewed as a sequence of 2-mm thick transverse, sagittal, or frontal sections or as a 3-dimensional shaded surface. The functional volume of the thyroid may be estimated by counting the volume elements (voxels) inside the thyroid surface. The precision of the estimate varied from 6-15%, depending on the size and clinical status of the thyroid. The volume estimation procedure was validated with phantoms and with the thyroids of patients who subsequently underwent partial thyroidectomy. This 3-dimensional imaging technique may be useful for diagnosis and management of thyroid diseases

  6. Radioiodine therapy of benign thyroid disorders: functional thyroid autonomy

    International Nuclear Information System (INIS)

    Dunkelmann, S.

    2005-01-01

    In the last 15 years, several concepts have been developed to further improve the outcome of radioiodine therapy in functional thyroid autonomy. Results of radioiodine therapy in functional autonomy are considerably better than in Graves' disease. All of the currently-applied concepts offer healing rates of 75-100%, but they differ considerably in the hypothyreosis rates attained. The target volume can be precisely determined by sonography only in unifocal autonomy. In the case of multifocal and disseminated autonomy, the entire thyroid is taken as the target volume and the focal dose is reduced ('dosimetric compromise'). TcTUs-based dose concepts calculate the functionally autonomous volume from the TcTUs and replace the target volume by sonography, in the TcTUs-adapted dose concepts, sonographic target volume is left and the focal dose varied in dependence of the suppression uptake. The objective is to attain a high rate of success with a low rate of hypothyreosis. (orig.)

  7. Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma.

    Science.gov (United States)

    Simavli, Huseyin; Poon, Linda Yi-Chieh; Que, Christian J; Liu, Yingna; Akduman, Mustafa; Tsikata, Edem; de Boer, Johannes F; Chen, Teresa C

    2017-06-01

    To determine the diagnostic capability of spectral domain optical coherence tomography peripapillary retinal volume (RV) measurements. A total of 156 patients, 89 primary open-angle glaucoma and 67 normal subjects, were recruited. Spectral domain optical coherence tomography peripapillary RV was calculated for 4 quadrants using 3 annuli of varying scan circle diameters: outer circumpapillary annuli of circular grids 1, 2, and 3 (OCA1, OCA2, OCA3). Area under the receiver operating characteristic curves and pairwise comparisons of receiver operating characteristic (ROC) curves were performed to determine which quadrants were best for diagnosing primary open-angle glaucoma. The pairwise comparisons of the best ROC curves for RV and retinal nerve fiber layer (RNFL) were performed. The artifact rates were analyzed. Pairwise comparisons showed that the smaller annuli OCA1 and OCA2 had better diagnostic performance than the largest annulus OCA3 (Pglaucoma patients but also a subset of early glaucoma patients. The inferior quadrant of peripapillary annulus OCA1 demonstrated the best diagnostic capability for both glaucoma and early glaucoma. The diagnostic ability of RV is comparable with that of RNFL parameters in glaucoma but with lower artifact rates.

  8. Ultrasound measurements of testicular volume: Comparing the three ...

    African Journals Online (AJOL)

    T.U. Mbaeri

    Thus, a reduction in the number of these cells is manifested in a reduction in testicular volume [3]. Reliable and accurate determination of the testicular volume is of .... sound formulas 1, 2 and 3 was found to be statistically significant. (p < 0.0001, p < 0.0001, p < 0.05, respectively) (Table 1). Table 1 also shows the correlation ...

  9. Role of chronic hemodialysis in thyroid gland morphology disorders.

    Science.gov (United States)

    Jusufovic, Selma; Hodzic, Emir

    2011-01-01

    Thyroid gland morphology is affected in patients with chronic kidney disease. The purpose of this study was to compare thyroid gland morphology among patients on chronic hemodialysis (HD) and healthy participants and to assess the duration of dialysis on thyroid disorders. Prospective study included 80 participants divided into two groups. Study group included 40 patients on (HD) who were divided in two subgroups, according to the time spent on dialysis (i.e. under and over 72 months). The exclusion critheria was represented by the previous thyroid disorders and systemic illnesses. The control group included 40 healthy participants. The blood samples were taken for standard laboratory analysis, total and free thyroid hormone levels. Thyroid ultrasound was performed, thyroid wolume was calculated and the echostructure assessed. Mean values of thyroid volume were increased in HD patients (e.g.18,88 +/- 3,20 ml, p thyroid volume (r = -0.05, NS) and TSH levels (r = 0.14, NS). A significant, positive correlation between the thyroid volume and TSH levels was observed in HD group of patients (r = 0.24 p Thyroid disorders are more common in patients on HD compared to general population. These findings suggest that thyroid morphology screening should be performed in HD patients.

  10. The clinical significance of measuring the thyroid 131I uptake rate to identify the type of premature hypothyroidism for hyperthyroid after 131I treatment

    International Nuclear Information System (INIS)

    Deng Bo; Chen Huaming; Zhu Tianfeng

    2001-01-01

    The 3 h thyroid 131 I uptake rate and the content of serum TT 3 , TT 4 , TSH are measured in 63 patients of premature hypothyroidism (consisting of 33 provisional hypothyroids and 30 perpetual hypothyroidism) before and after thyroxine substitutes treatment for six moths. The results show that there is obvious difference in 131 I uptake rate compared provisional hypothyroidism with perpetual hypothyroidism, and no difference in the content of serum TT 3 , TT 4 , TSH before the treatment. Compared with normal conditions, there is no difference in 131 I uptake rate of provisional hypothyroidism, but the 131 I uptake rate of perpetual hypothyroidism has obvious decrease before and after the treatment. Therefore the type of patients who suffer from premature hypothyroidism can be distinguished according to the 131 I uptake rate: if the 3 h thyroid 131 I uptake rate is normal, it is provisional hypothyroidism; if not, it is perpetual hypothyroidism

  11. Three-dimensional reconstruction volume: a novel method for volume measurement in kidney cancer.

    Science.gov (United States)

    Durso, Timothy A; Carnell, Jonathan; Turk, Thomas T; Gupta, Gopal N

    2014-06-01

    The role of volumetric estimation is becoming increasingly important in the staging, management, and prognostication of benign and cancerous conditions of the kidney. We evaluated the use of three-dimensional reconstruction volume (3DV) in determining renal parenchymal volumes (RPV) and renal tumor volumes (RTV). We compared 3DV with the currently available methods of volume assessment and determined its interuser reliability. RPV and RTV were assessed in 28 patients who underwent robot-assisted laparoscopic partial nephrectomy for kidney cancer. Patients with a preoperative creatinine level of kidney pre- and postsurgery overestimated 3D reconstruction volumes by 15% to 102% and 12% to 101%, respectively. In addition, volumes obtained from 3DV displayed high interuser reliability regardless of experience. 3DV provides a highly reliable way of assessing kidney volumes. Given that 3DV takes into account visible anatomy, the differences observed using previously published methods can be attributed to the failure of geometry to accurately approximate kidney or tumor shape. 3DV provides a more accurate, reproducible, and clinically useful tool for urologists looking to improve patient care using analysis related to volume.

  12. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    International Nuclear Information System (INIS)

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao

    2013-01-01

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  13. Sonographic appearance of thyroid cancer in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Durfee, Sara M; Benson, Carol B; Arthaud, Dylan M; Alexander, Erik K; Frates, Mary C

    2015-04-01

    To determine whether the sonographic appearance of thyroid cancer differs in patients with and without Hashimoto thyroiditis. Patients with histologically proven thyroid cancer who had thyroid peroxidase (TPO) antibodies measured and sonography performed preoperatively were included. We evaluated each nodule for size, echogenicity, composition, margins, halo, and vascularity and evaluated the background heterogeneity of the gland. There were 162 thyroid cancers in 145 patients. Forty-two patients (29.0%) had Hashimoto thyroiditis with positive TPO antibodies, and 103 patients (71.0%) had negative TPO antibodies. The background echogenicity was more often heterogeneous in TPO antibody-positive patients compared to those who had negative TPO antibodies (57.1% versus 26.2%; P= .0005). Comparing cancers in TPO antibody-positive to TPO antibody-negative patients, there was no significant difference in the size, echogenicity, composition, margins, halo presence, calcification presence and type, or vascularity of the cancerous nodule (P > .05). Among TPO antibody-positive patients, comparing thyroid cancerous nodules in patients with heterogeneous glands to those with homogeneous glands, there was no significant difference in any sonographic characteristic except the margin of the nodule, which was more often irregular or poorly defined in heterogeneous glands and more often smooth in homogeneous glands (PHashimoto thyroiditis. Among patients with Hashimoto thyroiditis and thyroid cancer, the sonographic appearance of the cancerous nodule is similar, except that cancerous nodule margins are more likely to be irregular or poorly defined when the gland is heterogeneous. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Routine calcium measurement is not necessary after most thyroid surgeries: a prospective clinical study.

    LENUS (Irish Health Repository)

    Quinn, E M

    2010-12-01

    Calcium levels are often measured to diagnose postoperative hypocalcaemia following thyroidectomy. The aims of this study were to (i) prospectively determine the incidence of symptomatic and biochemical hypocalcaemia following thyroidectomy, (ii) to identify if any associations exist between hypocalcaemia, type of surgery, histological diagnosis, specimen size\\/weight and the presence of histological parathyroid tissue and (iii) to evaluate the necessity of routine measurement of calcium levels following all thyroidectomies.

  15. Combination therapy of temporary tracheal stenting and radiofrequency ablation for multinodular thyroid goiter with airway compression

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Beak, Jung Hwan; Oh, Yeon Mok; Ha, Eun Ju; Lee, Jeong Hyun

    2013-01-01

    We report a case of multinodular thyroid goiter in an 80-year-old man who successfully underwent tracheal stent placement for respiratory distress caused by the thyroid goiter and following two radiofrequency (RF) ablation sessions performed for thyroid volume reduction. This sequential treatment allowed elective stent removals four weeks after the second RF ablation session because the thyroid volume had been progressively reduced. Combination therapy of temporary airway stenting and RF ablation for the treatment of thyroid goiter has two advantages, i.e., immediate reliefs of dyspnea with airway stenting and reductions of the thyroid volume with RF ablation, and thus, allowing symptom reliefs even after the stent removals.

  16. Combination therapy of temporary tracheal stenting and radiofrequency ablation for multinodular thyroid goiter with airway compression

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Beak, Jung Hwan; Oh, Yeon Mok; Ha, Eun Ju; Lee, Jeong Hyun [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2013-10-15

    We report a case of multinodular thyroid goiter in an 80-year-old man who successfully underwent tracheal stent placement for respiratory distress caused by the thyroid goiter and following two radiofrequency (RF) ablation sessions performed for thyroid volume reduction. This sequential treatment allowed elective stent removals four weeks after the second RF ablation session because the thyroid volume had been progressively reduced. Combination therapy of temporary airway stenting and RF ablation for the treatment of thyroid goiter has two advantages, i.e., immediate reliefs of dyspnea with airway stenting and reductions of the thyroid volume with RF ablation, and thus, allowing symptom reliefs even after the stent removals.

  17. Comparison of thyroid stimulating activities measured by cyclic AMP production, those by radioiodine uptake in FRTL-5 cells and TSH-binding inhibitory activities in patients with hyperthyroid and euthyroid Graves' diseases

    International Nuclear Information System (INIS)

    Kasagi, Kanji; Hatabu, Hiroto; Tokuda, Yasutaka; Arai, Keisuke; Iida, Yasuhiro; Konishi, Junji

    1988-01-01

    By using an assay measuring cAMP production in FRTL-5 thyroid cells, thyroid stimulating antibodies (TSab) were detected in all of 15 patients with euthyroid Graves' disease (EG) and of 26 patients with hyperthyroid Graves' disease (HG). There was no signicant difference between TSab activities in Eg and in HG. In an effort to elucidate why EG patients remain euthyroid in spite of having TSab, we investigated the effect of the patient's crude immunoglobulin fractions 125 I uptake in FRTL-5 thyroid cells, one of the indices of stimulation subsequent to cAMP production. The 125 Iuptake stimulation (IUS) activity was positive in 46,7% (7/15) of EG patients and 88.5% (23/26) of HG patients, being significantly lower in the former than in the latter (P 99m Tc thyroid uptake (r = 0.401, P 99m Tc thyroid uptake in comparison to 19 HG patients with a similar range of IUS activities. There was a good correlation between thyroid weight and 99m Tc thyroid uptake (r = 8.827, P 99m Tc and presumably radioiodine in vivo, might be a factor responsible for keeping EG patients euthyroid despite the presence of TSab. (author)

  18. Thyroid stimulating hormone and subclinical thyroid dysfunction

    International Nuclear Information System (INIS)

    Guo Yongtie

    2008-01-01

    Subclinical thyroid dysfunction has mild clinical symptoms. It is nonspecific and not so noticeable. It performs only for thyroid stimulating hormone rise and decline. The value of early diagnosis and treatment of thyroid stimulating hormone in subclinical thyroid dysfunction were reviewed. (authors)

  19. Activation volume measurement techniques: application to Zircaloy-4

    International Nuclear Information System (INIS)

    Cuniberti, A.; Picasso, A.

    2001-01-01

    Stress relaxation and strain rate change tests were performed in Zircaloy-4 at room temperature. The apparent and effective activation volumes were determined and the results obtained by the different techniques are compared. The stress dependence of activation volumes is studied in a broad range of stresses, and an analysis is made in the light of the thermal activation theory. The results suggest that plasticity is ruled by the overcoming of Peierls barriers. (orig.)

  20. [Autoimmune thyroiditis and thyroid cancer].

    Science.gov (United States)

    Krátký, Jan; Jiskra, Jan

    2015-10-01

    Association between autoimmune thyroiditis (CLT) and thyroid cancer remains not clear. Although both diseases often occur simultaneously in histological samples, it is not yet clear whether CLT can be regarded as a risk factor for thyroid malignancy. This review focus on the known epidemiological and molecular genetics links between both diseases. Most studies have shown a significant association between thyroid cancer and positive antibodies to thyroglobulin and histological evidence of CLT, as well. Both disorders share some risk factors (greater incidence in women, in areas with adequate supply of iodine and in patients after radiotherapy of the neck) and molecular genetics linkage. For example: RET/PTC rearrangements could be more often found in carcinomas associated with CLT, but this mutation could be found in benign lesions such as CLT, as well. CLT seems to be a positive prognostic factor in patients with differentiated thyroid cancer. It is associated with less invasive forms of tumor, lower occurrence of infiltrated lymphatic nodes and a lower risk of recurrence.

  1. Comparison of three different assays for measuring thyroglobulin and thyroglobulin antibodies in patients with chronic lymphocytic thyroiditis.

    Science.gov (United States)

    Cheng, Xinqi; Yu, Songlin; Jin, Cheng; Han, Song; Hu, Yingying; Zhang, Kui; Liu, Huaicheng; Qiu, Ling

    2017-12-01

    To evaluate how thyroglobulin (Tg) and thyroglobulin antibody (TgAb) results compare among different chemiluminescence methods. Serum specimens from 153 patients with thyroiditis and 127 apparently healthy individuals were collected at the Peking Union Medical College Hospital from September 2014 to December 2014. TgAb and Tg levels were analyzed by using three different platforms manufactured by Roche, Beckman, and Siemens. The χ 2 test was performed to analyze the TgAb results from the different methods. Passing-Bablok regression equations and Bland-Altman plots were used to estimate the relationship and bias among the Tg results obtained with the different analyses. The overall coincidence rates for the TgAb results were 82.9% between the Beckman and Roche methods, 78.6% between the Siemens and Roche methods, and 81.1% between the Siemens and Beckman methods. The borderline positive coincidence rate among the different TgAb methods was very poor (9.1-24.2%). Of the 280 samples, the TgAb results for 26.4% of the samples differed among the three CLIA platforms. A good linear relationship among the Tg levels was shown in TgAb-negative subjects analyzed with the different CLIA systems. However, for TgAb-positive subjects, the linear relationship of the Tg levels measured with the Siemens system, compared with the other two systems, was poor. Bland-Altman plots demonstrated significant differences among the different Tg assays. Current Tg and TgAb methods are highly variable and cannot be used interchangeably. Copyright © 2017. Published by Elsevier Inc.

  2. Validation and application of noninvasive glucocorticoid and thyroid hormone measures in free-ranging Hawaiian monk seals.

    Science.gov (United States)

    Gobush, K S; Booth, R K; Wasser, S K

    2014-01-01

    We validate fecal glucocorticoid (GC) and thyroid (T3) hormone metabolite measures in the Critically Endangered Hawaiian monk seal for the first time, and examine variation in the concentrations of these hormones in individuals across the species' range. We test hypotheses that monk seals from declining subpopulations have relatively high GCs and low T3 on average suggesting impacts of food limitation, and that this hormone pattern is more apparent in immature animals compared to adults, as food limitation is specifically indicated as a principal cause of poor body condition and survival of juvenile monk seals. We opportunistically sampled scat from 84 individually identifiable monk seals during the 2010 breeding season from two geographic regions, the main Hawaiian Islands (MHI) and the Northwestern Hawaiian Islands (NWHI). The MHI subpopulation of monk seals is growing, whereas subpopulations at many sites in the NWHI are in decline. Best fit general linear models predicting variation in GCs and T3 (examined separately) were similar (after accounting for significantly elevated hormone concentrations associated with molt and possibly lactation); both included sample date, region, and monk seal age as predictors. GC concentrations were significantly lower in MHI versus NWHI monk seals and decreased as the breeding season progressed. T3 concentrations were significantly lower in immature monk seals compared to adults. GC and T3 concentrations were positively correlated at 4 NWHI sites; prey may be adequate for physiological growth or maintenance at these sites but relatively stressful to acquire. GCs were highest at French Frigate Shoals, (a NWHI site) while T3 was relatively low here, indicating a possible signal of food limitation. GCs were lowest in the MHI. Disturbance associated with living near a high human population in the MHI appears to impact monk seal physiology less than other stressors encountered in the remote and highly protected NWHI where human

  3. Prognostic factors of the outcomes of subtotal thyroid resection in graves disease

    Directory of Open Access Journals (Sweden)

    A J Tsurkan

    2011-03-01

    Full Text Available The long-term results of subtotal resection of thyroid gland on 82 patients with Graves' disease were studied. There was analysed the influence of three factors on outcome at Graves' disease: volume of a thyroid gland before operation, morphological structure of thyroid tissue and volume of thyroid remnant. Outcomes of subtotal resection of thyroid gland were studied on the basis of thyrotropic hormone level of blood in 3, 6, 12 months, 2 and 3 years after operation. Based on research it has been established that the volume of thyroid gland before operation does not influence to outcome of subtotal resection of thyroid gland with Graves' disease. Morphological changes of removed thyroid tissue in the form of colloidal nodules at patients with Graves' disease statistically significantly raise risk of development of postoperative complications after subtotal resection of thyroid gland. The surgeon defining the volume of thyroid rem-nant durng the operation could be mistaken as towards it's increase so towards it's reduction, with an average deviation about 35%. Various outcomes of subtotal resection of thyroid gland at the same volume of thyroid remnant let us conclude that this out-come depends more on intensity of autoimmune process rather than on the volume of thyroid remnant. According modern views to aetiology and patogenesis of Graves' disease, the optimum volume of operation at Graves' disease is thyroidectomy.

  4. Pathological evaluation of thyroid glands in Graves' disease after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Xiao Haipeng; Cheng Wei; Yang Jianyong; Chen Guorui; Ling Qibo

    2003-01-01

    Objective: To study the pathological morphology of thyroid specimen after thyroid arteries embolization. In order to select appropriate size of embolizing granules, the diameters of thyroid arteries in Graves' disease were measured. Methods: Multiple slides of embolized thyroid tissues from superior pole, body and inferior pole of the resected thyroid glands were made. After being embedded and stained, pathological morphology was observed and diameters of arteries in various parts of thyroid glands were measured under microscopy. Results: Pathological examination of thyroid glands showed that superior and inferior thyroid arteries and most of their branches were embolized with ischemic necrosis and fibrosis in the embolized thyroid tissue. Follicular epithelium appeared as flat or cubic shapes with colloid reduction. Average diameter of main branches of superior artery was 440-550 μm and that of inferior artery was 300-375 μm. The diameters of capillary network in the thyroid body was 120-250 μm, and the non-embolized ones was 40-110 μm. The diameter of isthmus was 130-150 μm. Conclusions: Pathological morphology of Graves' disease after thyroid arteries embolization showed that the excretion of thyroid glands would be decreased and equivalents to subtotal thyroidectomy

  5. Axial Globe Position Measurement: A Prospective Multi-center Study by the International Thyroid Eye Disease Society

    Science.gov (United States)

    Bingham, Chad M.; Sivak-Callcott, Jennifer A.; Gurka, Matthew J.; Nguyen, John; Hogg, Jeffery P.; Feldon, Steve E.; Fay, Aaron; Seah, Lay-Leng; Strianese, Diego; Durairaj, Vikram D.; Uddin, Jimmy; Devoto, Martin H.; Harris, Matheson; Saunders, Justin; Osaki, Tammy H.; Looi, Audrey; Teo, Livia; Davies, Brett W.; Elefante, Andrea; Shen, Sunny; Realini, Tony; Fischer, William; Kazim, Michael

    2015-01-01

    Purpose Identify a reproducible measure of axial globe position (AGP) for multicenter studies of patients with thyroid eye disease (TED). Methods This is a prospective, international, multicenter, observational study in which 3 types of AGP evaluation were examined: radiologic, clinical, and photographic. In this study, computed tomography (CT) was the modality to which all other methods were compared. CT AGP was measured from an orthogonal line between the anterior lateral orbital rims to the cornea. All CT measurements were made at a single institution by 3 individual clinicians. Clinical evaluation was performed with exophthalmometry. Three clinicians from each clinical site assessed AGP with 3 different exophthalmometers and horizontal palpebral width using a ruler. Each physician made 3 separate measurements with each type of exophthalmometer, not in succession. All photographic measurements were made at a single institution. AGP was measured from lateral photographs in which a standard marker was placed at the anterior lateral orbital rim. Horizontal and vertical palpebral fissure were measured from frontal photographs. Three trained readers measured 3 separate times, not in succession. Exophthalmometry and photography method validity was assessed by agreement with CT (mean differences calculation, ICC’s, Bland-Altman figures). Correlation between palpebral fissure and CT AGP was assessed with Pearson correlation. Intraclinician and interclinician reliability was evaluated using intraclass correlation coefficients (ICC). Results Sixty-eight patients from 7 centers participated. CT mean AGP was 21.37mm (15.96 – 28.90mm) right, 21.22mm (15.87 – 28.70mm) left (ICC 0.996 and 0.995). Exophthalmometry AGP fell between 18mm and 25mm. Intraclinician agreement across exophthalmometers was ideal (ICC 0.948 – 0.983). Agreement between clinicians was greater than 0.85 for all upright exophthalmometry measurements. Photographic mean AGP was 20.47mm (10.92 – 30

  6. Evaluation of thyroid function tests in non-thyroidal illness

    International Nuclear Information System (INIS)

    Schutte, D.P.

    1988-01-01

    Normal thyroid physiology and pathophysiology with reference to non-thyroidal illness (NTI) is reviewed including specific disease states and drugs and their effect on thyroid function tests. The diagnostic utility of two new highly sensitive thyrotrophin (TSH) assays as screening tests for thyroid dysfunction are evaluated and compared with conventional thyroid function assays. A group of 40 patients with NTI was studied. This group was compared to a group of normal controls and a group of thyrotoxic patients. Conventional thyroid function tests yielded many values outside the reference range in the NTI group. The general pattern that emerged was decreased total triiodothyronine levels in 70% of NTI patients, normal to low thyroxine values, increased mean free thyroxine values (dialysis), low mean values for the free thyroxine index and varying results for newer commercial assays for free thyroxine according to methodology. The TSH response to intravenous thyroliberin (TRH) was found to be blunted compared to controls. Basal TSH levels were measured with two ultasensitive TSH assays. The immunoradiometric assays yielded fewer values outside the reference range in the NTI group than conventional thyroid function tests. This assay yielded undetectable basal TSH levels in all thyrotoxic patients and could reliably separate thyrotoxic patients from the NTI group. Basal TSH levels with ultrasensitive TSH assays correlated well with the TSH response to TRH (TSH) and could obviate the need for TRH tests. Ultrasensitive TSH assays are promising first line screening tests in NTI. 120 refs., 13 figs., 7 tabs

  7. Large discrepancy in the results of sensitive measurements of thyroglobulin antibodies in the follow-up on thyroid cancer

    DEFF Research Database (Denmark)

    Nygaard, Birte; Bentzen, Jens; Laurberg, Peter

    2012-01-01

    UNLABELLED: During follow-up on patients treated for differentiated thyroid cancer, thyroglobulin (Tg) antibodies can interfere with the Tg assay, making the use of Tg less reliable as a tumor marker. PURPOSE: To compare Tg and Tg autoantibodies (Tg-Ab) methods used in Denmark, regarding the number...

  8. Effects of Measurement Errors on Individual Tree Stem Volume Estimates for the Austrian National Forest Inventory

    Science.gov (United States)

    Ambros Berger; Thomas Gschwantner; Ronald E. McRoberts; Klemens. Schadauer

    2014-01-01

    National forest inventories typically estimate individual tree volumes using models that rely on measurements of predictor variables such as tree height and diameter, both of which are subject to measurement error. The aim of this study was to quantify the impacts of these measurement errors on the uncertainty of the model-based tree stem volume estimates. The impacts...

  9. The Use of Helmholtz Resonance for Measuring the Volume of Liquids and Solids

    Directory of Open Access Journals (Sweden)

    Clive E. Davies

    2010-11-01

    Full Text Available An experimental investigation was undertaken to ascertain the potential of using Helmholtz resonance for volume determination and the factors that may influence accuracy. The uses for a rapid non-interference volume measurement system range from agricultural produce and mineral sampling through to liquid fill measurements. By weighing the sample the density can also measured indirectly.

  10. Volume measurement variability in three-dimensional high-frequency ultrasound images of murine liver metastases

    International Nuclear Information System (INIS)

    Wirtzfeld, L A; Graham, K C; Groom, A C; MacDonald, I C; Chambers, A F; Fenster, A; Lacefield, J C

    2006-01-01

    The identification and quantification of tumour volume measurement variability is imperative for proper study design of longitudinal non-invasive imaging of pre-clinical mouse models of cancer. Measurement variability will dictate the minimum detectable volume change, which in turn influences the scheduling of imaging sessions and the interpretation of observed changes in tumour volume. In this paper, variability is quantified for tumour volume measurements from 3D high-frequency ultrasound images of murine liver metastases. Experimental B16F1 liver metastases were analysed in different size ranges including less than 1 mm 3 , 1-4 mm 3 , 4-8 mm 3 and 8-70 mm 3 . The intra- and inter-observer repeatability was high over a large range of tumour volumes, but the coefficients of variation (COV) varied over the volume ranges. The minimum and maximum intra-observer COV were 4% and 14% for the 1-4 mm 3 and 3 tumours, respectively. For tumour volumes measured by segmenting parallel planes, the maximum inter-slice distance that maintained acceptable measurement variability increased from 100 to 600 μm as tumour volume increased. Comparison of free breathing versus ventilated animals demonstrated that respiratory motion did not significantly change the measured volume. These results enable design of more efficient imaging studies by using the measured variability to estimate the time required to observe a significant change in tumour volume

  11. Evaluation of left ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Thomsen, C; Mehlsen, J

    1986-01-01

    Left ventricular end-diastolic and end-systolic volumes were determined in 17 patients with different levels of left ventricular function by magnetic resonance imaging (MRI). A 1.5 Tesla Magnet was used obtaining ECG triggered single and multiple slices. Calculated cardiac outputs were compared...

  12. Automatically measuring brain ventricular volume within PACS using artificial intelligence.

    Science.gov (United States)

    Yepes-Calderon, Fernando; Nelson, Marvin D; McComb, J Gordon

    2018-01-01

    The picture archiving and communications system (PACS) is currently the standard platform to manage medical images but lacks analytical capabilities. Staying within PACS, the authors have developed an automatic method to retrieve the medical data and access it at a voxel level, decrypted and uncompressed that allows analytical capabilities while not perturbing the system's daily operation. Additionally, the strategy is secure and vendor independent. Cerebral ventricular volume is important for the diagnosis and treatment of many neurological disorders. A significant change in ventricular volume is readily recognized, but subtle changes, especially over longer periods of time, may be difficult to discern. Clinical imaging protocols and parameters are often varied making it difficult to use a general solution with standard segmentation techniques. Presented is a segmentation strategy based on an algorithm that uses four features extracted from the medical images to create a statistical estimator capable of determining ventricular volume. When compared with manual segmentations, the correlation was 94% and holds promise for even better accuracy by incorporating the unlimited data available. The volume of any segmentable structure can be accurately determined utilizing the machine learning strategy presented and runs fully automatically within the PACS.

  13. Measurement of lung fluid volumes and albumin exclusion in sheep

    International Nuclear Information System (INIS)

    Pou, N.A.; Roselli, R.J.; Parker, R.E.; Clanton, J.A.; Harris, T.R.

    1989-01-01

    A radioactive tracer technique was used to determine interstitial diethylenetriaminepentaacetic acid (DTPA) and albumin distribution volume in sheep lungs. 125 I- and/or 131 I-labeled albumin were injected intravenously and allowed to equilibrate for 24 h. 99m Tc-labeled DTPA and 51 Cr-labeled erythrocytes were injected and allowed to equilibrate (2 h and 15 min, respectively) before a lethal dose of thiamylal sodium. Two biopsies (1-3 g) were taken from each lung and the remaining tissue was homogenized for wet-to-dry lung weight and volume calculations. Estimates of distribution volumes from whole lung homogenized samples were statistically smaller than biopsy samples for extravascular water, interstitial 99m Tc-DTPA, and interstitial albumin. The mean fraction of the interstitium (Fe), which excludes albumin, was 0.68 +/- 0.04 for whole lung samples compared with 0.62 +/- 0.03 for biopsy samples. Hematocrit may explain the consistent difference. To make the Fe for biopsy samples match that for homogenized samples, a mean hematocrit, which was 82% of large vessel hematocrit, was required. Excluded volume fraction for exogenous sheep albumin was compared with that of exogenous human albumin in two sheep, and no difference was found at 24 h

  14. Thyroid Disorders (For Kids)

    Science.gov (United States)

    ... it keeps the temperature just right. What Is Thyroid Disease? There are two main kinds of thyroid disorder ... into the kid's bloodstream. Why Do Kids Get Thyroid Disease? In most cases, doctors and scientists can't ...

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the limitations of the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid ... body converts food to energy. top of page What are some common uses of the procedure? The ...

  16. Thyroid gland removal - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000293.htm Thyroid gland removal - discharge To use the sharing features ... surgery. This will make your scar show less. Thyroid Hormone Replacement You may need to take thyroid ...

  17. Hyperthyroidism (Overactive Thyroid)

    Science.gov (United States)

    Hyperthyroidism (overactive thyroid) Overview Hyperthyroidism (overactive thyroid) is a condition in which your thyroid gland produces too much of the hormone thyroxine. Hyperthyroidism can accelerate your body's metabolism significantly, ...

  18. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is ... computer, create pictures offering details on both the structure and function of organs and tissues in your ...

  19. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... of the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan is ... taking our brief survey: Survey Do you have a personal story about radiology? Share your patient story ...

  20. Thyroid cancer - papillary carcinoma

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000331.htm Thyroid cancer - papillary carcinoma To use the sharing features on ... does not increase the risk of developing thyroid cancer. Symptoms Thyroid cancer often begins as a small lump (nodule) ...

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... typically performed on people who have or had thyroid cancer. A physician may perform these imaging tests to: ... such as lumps (nodules) or inflammation determine whether thyroid cancer has spread beyond the thyroid gland evaluate changes ...

  2. Anaplastic thyroid cancer

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/000352.htm Anaplastic thyroid cancer To use the sharing features on this page, ... carcinoma is a rare and aggressive form of cancer of the thyroid gland. Causes Anaplastic thyroid cancer is an invasive ...

  3. Comparative analysis of two methods for measuring sales volumes during malaria medicine outlet surveys

    OpenAIRE

    Patouillard, Edith; Kleinschmidt, Immo; Hanson, Kara; Pok, Sochea; Palafox, Benjamin; Tougher, Sarah; O?Connell, Kate; Goodman, Catherine

    2013-01-01

    BACKGROUND There is increased interest in using commercial providers for improving access to quality malaria treatment. Understanding their current role is an essential first step, notably in terms of the volume of diagnostics and anti-malarials they sell. Sales volume data can be used to measure the importance of different provider and product types, frequency of parasitological diagnosis and impact of interventions. Several methods for measuring sales volumes are available, yet all have met...

  4. Screening for thyroid cancer in children

    International Nuclear Information System (INIS)

    Nagataki, S.; Ashizawa, K.

    1996-01-01

    In the screening of the thyroid diseases in the radiation exposed cohort, it is essential to make correct diagnosis and to measure radiation dose in every subjects in the cohort and to analyze the dose response relationship by the most appropriate statistical method. Thus, thyroid cancer, thyroid adenoma and autoimmune hypothyroidism were confirmed to be radiation-induced thyroid diseases among atomic bomb survivors. A group of investigators from Nagasaki university have been working in the thyroid part of Chernobyl Sasakawa Health and Medical Cooperation Project, and more than 80000 children were screened in 5 diagnostic centers (Mogilev, Gomel, Kiev, Korosten and Klincy). In order to make correct diagnosis, thyroid echo-tomography, measurements of serum levels of free thyroxine, TSH, titers of anti-thyroid antibodies were performed in every children in the cohort and aspiration biopsy was performed when necessary. Whole body Cs 137 radioactivity was also determined in every subjects. Children with thyroid cancer confirmed by histology (biopsy or operation) were 2 in Mogilev, 19 in Gomel, 6 in Kiev, 5 in Korosten and 4 in Klincy (until 1994). Since children screened in each center were less than 20000, prevalence of thyroid cancer was remarkably high (lowest 100 and highest 1000/million children) when compared to the other parts of the world (0.2 to 5/million/year). However, there was no dose response relationship between the prevalence of cancer or nodule and whole body Cs 137 radioactivity. Although a significant correlation between thyroid cancer and reconstructed thyroid I 131 dose was presented, there are no previous reports to prove that I 131 produces thyroid cancer in human. Investigation on external radiation and short lived isotopes along with I 131 may be important to elucidate the cause of thyroid cancer

  5. Radioiodine and thyroid gland

    Directory of Open Access Journals (Sweden)

    Takavar A

    1994-05-01

    Full Text Available Administration of a precise amount of activity in thyroid gland radioiodine (¹³¹I therapy is of prime importance. Several methods for this purpose have been suggested and used over many years. In this paper, a method for required ¹³¹I activity calculation for each case has been proposed. Major factors affecting ¹³¹I calculation such as gland volume, integral dose, and prescription index have been described. Using the method, ¹³¹I activity or any other radioisotope activity required for a certain case can be determined with a good estimate.

  6. Measurement of Tumor Volumes Improves RECIST-Based Response Assessments in Advanced Lung Cancer1

    Science.gov (United States)

    Mozley, P David; Bendtsen, Claus; Zhao, Binsheng; Schwartz, Lawrence H; Thorn, Matthias; Rong, Yuanxin; Zhang, Luduan; Perrone, Andrea; Korn, René; Buckler, Andrew J

    2012-01-01

    OBJECTIVE: This study was designed to characterize the reproducibility of measurement for tumor volumes and their longest tumor diameters (LDs) and estimate the potential impact of using changes in tumor volumes instead of LDs as the basis for response assessments. METHODS: We studied patients with advanced lung cancer who have been observed longitudinally with x-ray computed tomography in a multinational trial. A total of 71 time points from 10 patients with 13 morphologically complex target lesions were analyzed. A total of 6461 volume measurements and their corresponding LDs were made by seven independent teams using their own work flows and image analysis tools. Interteam agreement and overall interrater concurrence were characterized. RESULTS: Interteam agreement between volume measurements was better than between LD measurements (ı = 0.945 vs 0.734, P = .005). The variability in determining the nadir was lower for volumes than for LDs (P = .005). Use of standard thresholds for the RECIST-based method and use of experimentally determined cutoffs for categorizing responses showed that volume measurements had a significantly greater sensitivity for detecting partial responses and disease progression. Earlier detection of progression would have led to earlier changes in patient management in most cases. CONCLUSIONS: Our findings indicate that measurement of changes in tumor volumes is adequately reproducible. Using tumor volumes as the basis for response assessments could have a positive impact on both patient management and clinical trials. More authoritative work to qualify or discard changes in volume as the basis for response assessments should proceed. PMID:22348172

  7. Measurement of normal ocular volume by the use of computed ...

    African Journals Online (AJOL)

    T, CT scanner, and Siemens) was calculated. The dimensions were obtained at mid-ocular axial slices with maximum anterior-posterior dimension and maximum size of the eye lens. Result: The mean (mean ± 2 SD) ocular volume for both eyes was 5282.23 mm3±1755.13 mm3 (right eye was 5264.26 mm3 ± 1781.12 mm3; ...

  8. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, M.R.; de Witt Hamer, P.C.; van Boven, L.J.; Zwinderman, K.A.H.; Bouma, G.J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  9. Correlation between sonography and antibody activity in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Willms, Arnulf; Bieler, Dan; Wieler, Helmut; Willms, Diana; Kaiser, Klaus P; Schwab, Robert

    2013-11-01

    Patients with Hashimoto thyroiditis show structural changes of the thyroid that can be identified by a variety of sonographic criteria. We conducted this study to investigate whether there is a correlation between sonography and antibody activity and to assess the role of sonography in the diagnosis and follow-up of Hashimoto thyroiditis. In addition, we present a new classification system (termed the VESINC system [volume, echogenicity, sonographic texture, pseudonodular hypoechoic infiltration, nodules, and cysts]), which helps improve the clarity of sonographic findings. The study included 223 consecutive patients with previously diagnosed Hashimoto autoimmune thyroiditis who attended the thyroid clinic of the German Armed Forces Central Hospital in Koblenz for follow-up examinations between 2006 and 2008. Laboratory tests were performed to measure the levels of free triiodothyronine, free thyroxine, thyrotropin, anti-thyroglobulin antibodies (TgAbs), and antithyroid peroxidase antibodies (TPOAbs). Sonography was performed according to a strict protocol. We then assessed whether a correlation existed between antibody activity and the 6 sonographic variables of the VESINC system. Hypoechogenicity, heterogeneity, and pseudonodular hypoechoic infiltration were associated with significantly higher TPOAb activity (P Hashimoto thyroiditis.

  10. Cooled microwave ablation of thyroid nodules: Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Korkusuz, Yücel [Department of Nuclear Medicine, University Hospital Frankfurt (Germany); Mader, Oscar Maximilian, E-mail: info@dzta.de [Department of Nuclear Medicine, University Hospital Frankfurt (Germany); Kromen, Wolfgang [Department of Neuro Radiology University Hospital (Germany); Happel, Christian [Department of Nuclear Medicine, University Hospital Frankfurt (Germany); German Centre for Thermoablation of Thyroid Nodules, University Hospital, Frankfurt (Germany); Ahmad, Shadi [Department of General and Visceral Surgery, Agaplesion Elisabethenstift, Darmstadt (Germany); Gröner, Daniel; Koca, Mithat; Mader, Alexander [Department of Nuclear Medicine, University Hospital Frankfurt (Germany); Grünwald, Frank; Korkusuz, Hüdayi [Department of Nuclear Medicine, University Hospital Frankfurt (Germany); German Centre for Thermoablation of Thyroid Nodules, University Hospital, Frankfurt (Germany)

    2016-11-15

    Highlights: • cMWA is a safe and effective treatment for thyroid nodules. • Ultrasound imaging allows guidance during microwave ablation. • Pain level during cMWA treatment is reduced in comparison to RFA. - Abstract: Objective: To evaluate if internally cooled microwave ablation (cMWA) is a safe and effective method for treatment of benign and malign thyroid nodules. Methods: 9 patients with 11 symptomatic cold benign thyroid nodules and 1 recurrent thyroid carcinoma ranging in volume from 9.1 to 197 ml (mean size 52 ±  57 ml) were treated with cMWA. The mean age of the patients was 59 years. Pain during the treatment was measured on a 10-point scale. Side effects revealed by ultrasound or patients’ complaints were documented. Periablative efficacy was measured 24 h after cMWA as change (Δ) in serum thyreoglobulin (Tg). Nodule elasticity was measured on a 4-point scale, blood circulation and echogenicity on a 3-point scale. Results: All patients tolerated cMWA well. Median pain intensity averaged 2.1 ± 0.8 (range: 1–3). Postablative hematoma was observed in all cases. In no cases ablation led to hoarseness, superficial burns, nodule ruptures, vagal reactions or dysphagia. cMWA lead to a significant decrease of blood circulation, nodule echogenicity and a significant increase of elasticity (Δ  =  1.1  ±  0.33; 0.8  ±  0.4 and 1.1  ±  0.6 points)(p < 0.05). An average increase of 4495 ng/ml Tg was measured (p < 0.05). Conclusions: cMWA is an effective and secure method for treatment of thyroid nodules.

  11. Measurement of breast volume is a useful supplement to select candidates for surgical breast reduction

    DEFF Research Database (Denmark)

    Ikander, Peder; Drejøe, Jennifer Berg; Lumholt, Pavia

    2014-01-01

    , the indication seemed to be less clear-cut, and additional parameters need to be included. CONCLUSION: Breast volume can be used as an objective criterion in addition to the presently used criteria. Breast volume can easily be measured and has become appreciated by plastic surgeons dealing with patients...... in the period from January 2007 to March 2011 were included prospectively in the study. The patients' subjective complaints, height, weight and standard breast measurements were registered as well as the decision for or against surgery. Breast volume was measured using transparent plastic cups. RESULTS: Cut......-off values for breast volume were calculated based on whether or not the patients were offered reduction surgery. Most patients (93%) with a breast volume below 800 cc were not offered surgery, while most with a volume exceeding 900 cc were offered surgery (94%). In the grey zone between 800 and 900 cc...

  12. The evaluation of gallbladder contractibility for volume measurement by helical 3D-CT-cholangiography

    International Nuclear Information System (INIS)

    Hanaguri, Katsuro; Kimura, Hideaki; Kayashima, Yasuyo; Suemoto, Kouichiro; Makihata, Hiroshi; Maruhashi, Akira; Ohya, Toshihide; Ito, Katsuhide; Shen, Yun.

    1997-01-01

    As a new application of helical (spiral) scan, volume measurement has received a significant interest. Although it is important to evaluate gallbladder contractibility to decide on a treatment plan for a gallbladder lesion, qualitative analysis of gallbladder contractibility is very difficult owing to the fact that the volume of gallbladder can not be measured using usual DIC examination (plain X-P and tomography). In this study, the accuracy of volume measurement of helical CT was checked firstly by gallbladder phantom experiments. Then 128 cases of volume measurement of helical 3D CT Cholangiography (DIC-CT) were performed. Under the conditions of optimized scan technique (3 mm TH, 3 mm/s, 1 mm recon interval, Hispeed, GEMS), the difference of contractibility was obtained between clinical cases with and without thick wall. The experiment has shown that helical 3D CT volume measurement is very simple and highly accurate method which is useful for the evaluation of gallbladder contractibility. (author)

  13. Thyroid carcinoma

    International Nuclear Information System (INIS)

    Lambertini, Roberto; Dalurzo, Liliana; Jaen, Ana del V.

    2008-01-01

    In this document the case of a 66-year old woman is presented, with record of multi nodular goiter of 5 year of evolution, which is derived to scan ultrasound office to make a puncture-aspiration with thin needle because of the growth of nodular thyroid injuries. The ultrasound scan examination made before the puncture determine multiple dominant nodules of hyperplasia aspect between 15 and 25 mm of diameter and a small nodule of 6 mm suspected proliferate process. Despite its size, it was decided to include small nodule in injuries to a biopsy. The cytological study reveals nodular hyperplasia with carcinoma in the small nodule of 6 mm. A thyroidectomy is practiced on the patient. The deferred histological study of the thyroid gland confirms the finding of multi-nodular goiter with a small focus of papillar carcinoma. The ganglions examined were negative in the deferred examination [es

  14. Thyroid metastasectomy.

    Science.gov (United States)

    Montero, Pablo H; Ibrahimpasic, Tihana; Nixon, Iain J; Shaha, Ashok R

    2014-01-01

    Metastases to the thyroid gland are uncommon. Renal, lung, breast, and colon cancer and melanoma are the most common primary diseases implicated. Few retrospective series have been reported. Treatment decisions must be individualized, and will depend on the state of systemic disease. Selected patients could benefit from surgical treatment. Although most patients selected for surgery will not be cured, the aim of surgery is to avoid the complications of uncontrolled central neck disease. © 2013 Wiley Periodicals, Inc.

  15. Absorbed dose calculation from beta and gamma rays of 131I in ellipsoidal thyroid and other organs of neck with MCNPX code

    Directory of Open Access Journals (Sweden)

    Mohammad Mirzaie

    2012-09-01

    Full Text Available Background: The 131I radioisotope is used for diagnosis and treatment of hyperthyroidism and thyroid cancer. In optimized Iodine therapy, a specific dose must be reached to the thyroid gland with minimum radiation to the cervical spine, cervical vertebrae, neck tissue, subcutaneous fat and skin. Dose measurement inside the alive organ is difficult therefore the aim of this research was dose calculation in the organs by MCNPX code. Materials and Methods: First of all, the input file for MCNPX code has been prepared to calculate F6 and F8 tallies for ellipsoidal thyroid lobes with long axes is tow times of short axes which the 131I is distributed uniformly inside the lobes. Then the code has been run for F6 and F8 tallies for variation of lobe volume from 1 to 25 milliliters. From the output file of tally F6, the gamma absorbed dose in ellipsoidal thyroid, spinal neck, neck bone, neck tissue, subcutaneous fat layer and skin for the volume lobe variation from 1 ml to 25 ml have been derived and the graphs are drew. As well as, form the output of F8 tally the absorbed energy of beta in thyroid and soft tissue of neck is obtained and listed in the table and then absorbed dose of bate has been calculated. Results: The results of this research show that for constant activity in thyroid, the absorbed dose of gamma decreases about 88.3% in thyroid, 6.9% at soft tissue, 19.3% in adipose layer and 17.4% in skin, but it increases 32.1% in spinal of neck and 32.3% in neck bone when the lobe volume varied from 1 to 25 milliliters. For the same situation, the beta absorbed dose decreases 95.9% in thyroid and 64.2% in soft tissue. Conclusion: For the constant activity in thyroid by increasing the thyroid volume, absorbed dose of gamma in thyroid and soft tissue of neck, adipose layer under the skin and skin of neck decreased, but it increased at spinal of neck and neck bone. Also, by increasing of the lobe volume in constant activity, the beta absorbed dose

  16. Comparison between ultrasonographic and caliper measurements of testicular volume in the dog.

    Science.gov (United States)

    Gouletsou, Pagona G; Galatos, Apostolos D; Leontides, Leonidas S

    2008-10-01

    The aim of this study was to compare the accuracy of two methods used to clinically estimate testicular volume in the dog. Caliper and ultrasonographic measurements of testicular dimensions (length, width and height) of both testes were performed on 21 adult Beagles. Either measurement was taken in vivo over the scrotal skin and again in vitro after castration, excluding or including, when possible, the epididymis. In a sub-sample of 14 testes of 7 randomly selected dogs, the testicular volume was calculated by the formula of an ellipsoid: length (l)xwidth (w)xheight (h)x0.5236, and the empiric formula of Lambert: (l)x(w)x(h)x0.71. The calculated volumes were then compared to the actual ones, which were estimated by water displacement. For each measurement method, the formula that estimated more accurately the true testicular volume was, subsequently, applied to the calculation of the testicular volume of the remaining testes. The formula of ellipsoid estimated testicular volume more accurately when in vivo and in vitro caliper measurements and in vitro ultrasound measurements were performed. The formula of Lambert estimated testicular volume more accurately when in vivo ultrasound measurements were performed. The volumes calculated from the measurements of calipers over the scrotal skin overestimated true volumes, on average, by 69+/-27% (concordance correlation coefficient r(ccc)=0.49). By contrast, those calculated from the ultrasonography measurements were more accurate, overestimating the true volumes by 17+/-24% (rccc=0.81). Therefore, ultrasonography when the formula of Lambert is used is more accurate than caliper methods for the estimation of testicular volume in clinical practice and should be the method of choice.

  17. Thyroid disorders in atomic-bomb survivors

    International Nuclear Information System (INIS)

    Imaizumi, M.; Neriishi, K.; Akahoshi, M.; Suzuki, G.; Nakashima, E.; Nagataki, S.; Eguchi, K.

    2003-01-01

    It is known from several studies, including those from RERF that radiation exposure can cause thyroid tumors (Socolow, N Engl J Med. 1963;268:406, Parker, Ann Intern Med. 1974;80:600). Effects of radiation on autoimmune thyroid disease are not well understood. We have conducted thyroid disease screening on a population of 2856 individuals from the Adult Health Study (AHS) cohort of atomic-bomb survivors for the period of 1984-1987. This study, which for logistical reasons involved survivors only from Nagasaki, revealed a statistically significant relationship between radiation dose and prevalence of solid nodules, including cancer, and that of autoimmune hypothyroidism (Nagataki, JAMA. 1994;272:364). Because the previous thyroid study was conducted only in Nagasaki, the new comprehensive thyroid disease screening study has been ongoing in Hiroshima and Nagasaki AHS participants since March 2000. For about 4,000 participants in Hiroshima and Nagasaki AHS cohort, thyroid ultrasonography, aspiration biopsy of nodules, thyroid function test, thyroid autoantibody (thyroid peroxidase antibody and thyroglobulin antibody) test by highly sensitive assay using enzyme linked immunosorbent assay were performed for the diagnosis of thyroid diseases. Analysis of data from the 1874 people examined through July 2001 (915 people from Hiroshima, 959 people from Nagasaki) provides evidence that thyroid cancer increases with radiation dose. The prevalence of positive result for thyroid autoantibody test is increased in the people exposed to relative low dose of radiation (0.01-0.99 Sv). Examination and measurements was completed in February 2003 for all patients. The analysis of these data is providing new and more complete insights into relationships between thyroid diseases and low doses of radiation

  18. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    The mean macula volume was 6.79 + 0.392 µm3. It was 6.861 , 0.297 in males, 6.496 , 0.520 in females and was statistically higher in males than females (P = 0.000). The mean central foveal thickness (MCFT) was 149.58±32.470 µm. It was 154.49 ± 34.652 µm in males and 133.33 ± 15.315 µm in females. MCFT was ...

  19. Adrenal gland volume measurement in septic shock and control patients: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nougaret, Stephanie; Aufort, S.; Gallix, B. [Hopital Saint Eloi, Department of Abdominal Imaging, CHU Montpellier, Montpellier, Cedex 5 (France); Jung, B.; Chanques, G.; Jaber, S. [Hopital Saint Eloi, Intensive Care Unit, Department of Critical Care and Anesthesiology: DAR B, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-10-15

    To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry. Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied. The mean total volume of both adrenal glands was 7.2 {+-} 2.0 cm{sup 3} in control subjects and 13.3 {+-} 4.7 cm{sup 3} for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care. The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy. (orig.)

  20. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  1. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  2. Comparison of thyroid segmentation techniques for 3D ultrasound

    Science.gov (United States)

    Wunderling, T.; Golla, B.; Poudel, P.; Arens, C.; Friebe, M.; Hansen, C.

    2017-02-01

    The segmentation of the thyroid in ultrasound images is a field of active research. The thyroid is a gland of the endocrine system and regulates several body functions. Measuring the volume of the thyroid is regular practice of diagnosing pathological changes. In this work, we compare three approaches for semi-automatic thyroid segmentation in freehand-tracked three-dimensional ultrasound images. The approaches are based on level set, graph cut and feature classification. For validation, sixteen 3D ultrasound records were created with ground truth segmentations, which we make publicly available. The properties analyzed are the Dice coefficient when compared against the ground truth reference and the effort of required interaction. Our results show that in terms of Dice coefficient, all algorithms perform similarly. For interaction, however, each algorithm has advantages over the other. The graph cut-based approach gives the practitioner direct influence on the final segmentation. Level set and feature classifier require less interaction, but offer less control over the result. All three compared methods show promising results for future work and provide several possible extensions.

  3. Cross-cultural validity of the thyroid-specific quality-of-life patient-reported outcome measure, ThyPRO.

    Science.gov (United States)

    Watt, Torquil; Barbesino, Giuseppe; Bjorner, Jakob Bue; Bonnema, Steen Joop; Bukvic, Branka; Drummond, Russell; Groenvold, Mogens; Hegedüs, Laszlo; Kantzer, Valeska; Lasch, Kathryn E; Marcocci, Claudio; Mishra, Anjali; Netea-Maier, Romana; Ekker, Merel; Paunovic, Ivan; Quinn, Terence J; Rasmussen, Åse Krogh; Russell, Audrey; Sabaretnam, Mayilvaganan; Smit, Johannes; Törring, Ove; Zivaljevic, Vladan; Feldt-Rasmussen, Ulla

    2015-03-01

    Thyroid diseases are common and often affect quality of life (QoL). No cross-culturally validated patient-reported outcome measuring thyroid-related QoL is available. The purpose of the present study was to test the cross-cultural validity of the newly developed thyroid-related patient-reported outcome ThyPRO, using tests for differential item functioning (DIF) according to language version. The ThyPRO consists of 85 items summarized in 13 multi-item scales and one single item. Scales cover physical and mental symptoms, well-being and function as well as social and daily function and cosmetic concerns. Translation applied standard forward-backward methodology with subsequent cognitive interviews and reviews. Responses (N = 1,810) to the ThyPRO were collected in seven countries: UK (n = 166), The Netherlands (n = 147), Serbia (n = 150), Italy (n = 110), India (n = 148), Denmark (n = 902) and Sweden (n = 187). Translated versions were compared pairwise to the English version by examining uniform and nonuniform DIF, i.e., whether patients from different countries respond differently to a particular item, although they have identical level of the concept measured by the item. Analyses were controlled for thyroid diagnosis. DIF was investigated by ordinal logistic regression, testing for both statistical significance and magnitude (ΔR (2) > 0.02). Scale level was estimated by the sum score, after purification. For twelve of the 84 tested items, DIF was identified in more than one language. Eight of these were small, but four were indicative of possible low translatability. Twenty-one instances of DIF in single languages were identified, indicating potential problems with the particular translation. However, only seven were of a magnitude which could affect scale scores, most of which could be explained by sample differences not controlled for. The ThyPRO has good cross-cultural validity with only minor cross-cultural invariance and is recommended for use in

  4. Serum BAFF and thyroid autoantibodies in autoimmune thyroid disease.

    Science.gov (United States)

    Lin, Jiunn-Diann; Wang, Yuan-Hung; Fang, Wen-Fang; Hsiao, Chia-Jung; Chagnaadorj, Amarzaya; Lin, Yuh-Feng; Tang, Kam-Tsun; Cheng, Chao-Wen

    2016-11-01

    This study investigated the association of serum B-lymphocyte activating factor (BAFF) levels with autoimmune thyroid disease (AITD) in a Chinese population. We enrolled 221 patients with AITD [170 patients with Graves' disease (GD), 51 patients with Hashimoto's thyroiditis (HT)], and 124 healthy controls. Serum BAFF levels, thyroid function and thyroid autoantibody (TAb) levels, including of thyroid-stimulating hormone receptor antibody (TSHRAb), anti-thyroid peroxidase antibody (Anti-TPO Ab), and antithyroglobulin antibody (ATA), were measured at baseline. Serum BAFF levels were higher in the GD, HT, and AITD groups than in the control group. Significant correlations were observed between BAFF and TSHRAb levels (r=0.238, p=0.018), between BAFF and Anti-TPO Ab levels (p=0.038), and between BAFF and ATA titers (p=0.025) in women but not in men. In addition, serum BAFF levels were significantly associated with free thyroxine (r=0.430, p=0.004) and TSHRAb (r=0.495, p=0.001) levels in women with active GD but not in those with inactive GD. Serum BAFF levels are increased in GD, HT, and AITD. The correlation between serum BAFF and TAb levels exhibits a dimorphic pattern, particularly in active GD. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. 12-month efficacy of a single radiofrequency ablation on autonomously functioning thyroid nodules.

    Science.gov (United States)

    Bernardi, Stella; Stacul, Fulvio; Michelli, Andrea; Giudici, Fabiola; Zuolo, Giulia; de Manzini, Nicolò; Dobrinja, Chiara; Zanconati, Fabrizio; Fabris, Bruno

    2017-09-01

    Radiofrequency ablation has been advocated as an alternative to radioiodine and/or surgery for the treatment of autonomously functioning benign thyroid nodules. However, only a few studies have measured radiofrequency ablation efficacy on autonomously functioning benign thyroid nodules. The aim of this work was to evaluate the 12-month efficacy of a single session of radiofrequency ablation (performed with the moving shot technique) on solitary autonomously functioning benign thyroid nodules. Thirty patients with a single, benign autonomously functioning benign thyroid nodules, who were either unwilling or ineligible to undergo surgery and radioiodine, were treated with radiofrequency ablation between April 2012 and May 2015. All the patients underwent a single radiofrequency ablation, performed with the 18-gauge needle and the moving shot technique. Clinical, laboratory, and ultrasound evaluations were scheduled at baseline, and after 1, 3, 6, and 12 months from the procedure. A single radiofrequency ablation reduced thyroid nodule volume by 51, 63, 69, and 75 % after 1, 3, 6, and 12 months, respectively. This was associated with a significant improvement of local cervical discomfort and cosmetic score. As for thyroid function, 33 % of the patients went into remission after 3 months, 43 % after 6 months, and 50 % after 12 months from the procedure. This study demonstrates that a single radiofrequency ablation allowed us to withdraw anti-thyroid medication in 50 % of the patients, who remained euthyroid afterwards. This study shows that a single radiofrequency ablation was effective in 50 % of patients with autonomously functioning benign thyroid nodules. Patients responded gradually to the treatment. It is possible that longer follow-up studies might show greater response rates.

  6. Experience in a specialist thyroid surgery unit

    DEFF Research Database (Denmark)

    al-Suliman, N N; Ryttov, N F; Qvist, N

    1997-01-01

    OBJECTIVE: To present a demographic study of thyroid diseases and thyroid surgical activity, to analyse the results of one department that has specialised in thyroid surgery during an 11-year period, and to try to define those groups of patients at increased risk of complications and untoward...... catchment area composed of five municipalities. MAIN OUTCOME MEASURES: Annual number of operations for goitre, waiting time to operation, incidence of complications, and sequelae. RESULTS: In the demographic study the number of patients operated on for benign thyroid diseases declined from about 50 cases...

  7. A method of measuring stacked objects volume based on laser sensing

    Science.gov (United States)

    Zhao, Qijie; Wu, Yijing; Li, Xianfa; Xu, Jiao; Meng, Qingxu

    2017-10-01

    Stacked objects volume measurement is now widely used in the fields of enterprise material management. It is significant to improve the efficiency of enterprise management and to reduce the cost of management and operation. The method based on laser sensing is one of the key methods to measure the stacked objects volume. This paper presents a laser sensing measurement method of stacked objects based on bottom plane extraction and real-time calibration. A calibration method for a laser scanning sensor and inertial measurement sensor is proposed. Three-dimensional reconstructions of stacked objects and volume calculations are carried out after acquisition and processing of point clouds. Volume measurement experiments of the single box and stacked boxes have been conducted respectively. Experimental results show that the measurement method is feasible and valid with good accuracy.

  8. Thyroid disease: thyroid function tests and interpretation

    African Journals Online (AJOL)

    Diseases of the thyroid are among the most prevalent of medical conditions, especially in women, but the symptoms can be relatively nonspecific or mild. For this reason, clinicians have been placing increased reliance on the laboratory for assistance in the diagnosis of thyroid disorders. In the 1950s, only one thyroid test ...

  9. Blood volume measurements in gopher snakes, using autologous 51Cr-labeled red blood cells.

    Science.gov (United States)

    Smeller, J M; Bush, M; Seal, U S

    1978-02-01

    Blood volume determinations were performed in 5 anesthetized gopher snakes (Pituophis melanoleucus catenifer) by means of a 51Cr-labeled red blood cell (RBC) method. The mean blood volume was 52.8 ml/kg of body weight (+/- 6.21 SE). Previous blood volume measurements have not been reported for this species. The RBC survival rate was estimated to be greater than 660 days. The RBC survival rate is long, but it cannot be determined accurately by this method.

  10. High-speed volume measurement system and method

    Science.gov (United States)

    Lane, Michael H.; Doyle, Jr., James L.; Brinkman, Michael J.

    2015-11-24

    Disclosed is a volume sensor having first, second, and third laser sources emitting first, second, and third laser beams; first, second, and third beam splitters splitting the first, second, and third laser beams into first, second, and third beam pairs; first, second, and third optical assemblies expanding the first, second, and third beam pairs into first, second, and third pairs of parallel beam sheets; fourth, fifth, and sixth optical assemblies focusing the first, second, and third beam sheet pairs into fourth, fifth, and sixth beam pairs; and first, second, and third detector pairs receiving the fourth, fifth, and sixth beam pairs and converting a change in intensity of at least one of the beam pairs resulting from an object passing through at least one of the first, second, and third parallel beam sheets into at least one electrical signal proportional to a three-dimensional representation of the object.

  11. High-speed volume measurement system and method

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Michael H.; Doyle, Jr., James L.; Brinkman, Michael J.

    2017-12-12

    Disclosed is a volume sensor having first, second, and third laser sources emitting first, second, and third laser beams; first, second, and third beam splitters splitting the first, second, and third laser beams into first, second, and third beam pairs; first, second, and third optical assemblies expanding the first, second, and third beam pairs into first, second, and third pairs of parallel beam sheets; fourth, fifth, and sixth optical assemblies focusing the first, second, and third beam sheet pairs into fourth, fifth, and sixth beam pairs; and first, second, and third detector pairs receiving the fourth, fifth, and sixth beam pairs and converting a change in intensity of at least one of the beam pairs resulting from an object passing through at least one of the first, second, and third parallel beam sheets into at least one electrical signal proportional to a three-dimensional representation of the object.

  12. Dedicated breast CT: Fibroglandular volume measurements in a diagnostic population

    Energy Technology Data Exchange (ETDEWEB)

    Vedantham, Srinivasan; Shi Linxi; Karellas, Andrew; O' Connell, Avice M. [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States); Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York 14642 (United States)

    2012-12-15

    Purpose: To determine the mean and range of volumetric glandular fraction (VGF) of the breast in a diagnostic population using a high-resolution flat-panel cone-beam dedicated breast CT system. This information is important for Monte Carlo-based estimation of normalized glandular dose coefficients and for investigating the dependence of VGF on breast dimensions, race, and pathology. Methods: Image data from a clinical trial investigating the role of dedicated breast CT that enrolled 150 women were retrospectively analyzed to determine the VGF. The study was conducted in adherence to a protocol approved by the institutional human subjects review boards and written informed consent was obtained from all study participants. All participants in the study were assigned BI-RADS{sup Registered-Sign} 4 or 5 as per the American College of Radiology assessment categories after standard diagnostic work-up and underwent dedicated breast CT exam prior to biopsy. A Gaussian-kernel based fuzzy c-means algorithm was used to partition the breast CT images into adipose and fibroglandular tissue after segmenting the skin. Upon determination of the accuracy of the algorithm with a phantom, it was applied to 137 breast CT volumes from 136 women. VGF was determined for each breast and the mean and range were determined. Pathology results with classification as benign, malignant, and hyperplasia were available for 132 women, and were used to investigate if the distributions of VGF varied with pathology. Results: The algorithm was accurate to within {+-}1.9% in determining the volume of an irregular shaped phantom. The study mean ({+-} inter-breast SD) for the VGF was 0.172 {+-} 0.142 (range: 0.012-0.719). VGF was found to be negatively correlated with age, breast dimensions (chest-wall to nipple length, pectoralis to nipple length, and effective diameter at chest-wall), and total breast volume, and positively correlated with fibroglandular volume. Based on pathology, pairwise statistical

  13. Estimation of rat mammary tumor volume using caliper and ultrasonography measurements.

    Science.gov (United States)

    Faustino-Rocha, Ana; Oliveira, Paula A; Pinho-Oliveira, Jacinta; Teixeira-Guedes, Catarina; Soares-Maia, Ruben; da Costa, Rui Gil; Colaço, Bruno; Pires, Maria João; Colaço, Jorge; Ferreira, Rita; Ginja, Mário

    2013-06-01

    Mammary tumors similar to those observed in women can be induced in rats by intraperitoneal administration of N-methyl-N-nitrosourea. Determining tumor volume is a useful and quantitative way to monitor tumor progression. In this study, the authors measured dimensions of rat mammary tumors using a caliper and using real-time compound B-mode ultrasonography. They then used different formulas to calculate tumor volume from these tumor measurements and compared the calculated tumor volumes with the real tumor volume to identify the formulas that gave the most accurate volume calculations. They found that caliper and ultrasonography measurements were significantly correlated but that tumor volumes calculated using different formulas varied substantially. Mammary tumors seemed to take on an oblate spheroid geometry. The most accurate volume calculations were obtained using the formula V = (W(2) × L)/2 for caliper measurements and the formula V = (4/3) × π × (L/2) × (L/2) × (D/2) for ultrasonography measurements, where V is tumor volume, W is tumor width, L is tumor length and D is tumor depth.

  14. Thyroid dose distribution in dental radiography

    International Nuclear Information System (INIS)

    Bristow, R.G.; Wood, R.E.; Clark, G.M.

    1989-01-01

    The anatomic position and proven radiosensitivity of the thyroid gland make it an organ of concern in dental radiography. A calibrated thermoluminescent dosimetry system was used to investigate the absorbed dose (microGy) to the thyroid gland resultant from a minimum irradiated volume, intraoral full-mouth radiography technique with the use of rectangular collimation with a lead-backed image receptor, and conventional panoramic radiography performed with front and rear lead aprons. Use of the minimum irradiated volume technique resulted in a significantly decreased absorbed dose over the entire thyroid region ranging from 100% to 350% (p less than 0.05). Because this intraoral technique results in radiographs with greater image quality and also exposes the thyroid gland to less radiation than the panoramic, this technique may be an alternative to the panoramic procedure

  15. Monte Carlo Method with Heuristic Adjustment for Irregularly Shaped Food Product Volume Measurement

    Directory of Open Access Journals (Sweden)

    Joko Siswantoro

    2014-01-01

    Full Text Available Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  16. Monte Carlo method with heuristic adjustment for irregularly shaped food product volume measurement.

    Science.gov (United States)

    Siswantoro, Joko; Prabuwono, Anton Satria; Abdullah, Azizi; Idrus, Bahari

    2014-01-01

    Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  17. Volume of preclinical xenograft tumors is more accurately assessed by ultrasound imaging than manual caliper measurements.

    Science.gov (United States)

    Ayers, Gregory D; McKinley, Eliot T; Zhao, Ping; Fritz, Jordan M; Metry, Rebecca E; Deal, Brenton C; Adlerz, Katrina M; Coffey, Robert J; Manning, H Charles

    2010-06-01

    The volume of subcutaneous xenograft tumors is an important metric of disease progression and response to therapy in preclinical drug development. Noninvasive imaging technologies suitable for measuring xenograft volume are increasingly available, yet manual calipers, which are susceptible to inaccuracy and bias, are routinely used. The goal of this study was to quantify and compare the accuracy, precision, and inter-rater variability of xenograft tumor volume assessment by caliper measurements and ultrasound imaging. Subcutaneous xenograft tumors derived from human colorectal cancer cell lines (DLD1 and SW620) were generated in athymic nude mice. Experienced independent reviewers segmented 3-dimensional ultrasound data sets and collected manual caliper measurements resulting in tumor volumes. Imaging- and caliper-derived volumes were compared with the tumor mass, the reference standard, determined after resection. Bias, precision, and inter-rater differences were estimated for each mouse among reviewers. Bootstrapping was used to estimate mean and confidence intervals of variance components, intraclass correlation coefficients (ICCs), and confidence intervals for each source of variation. The average deviation from the true volume and inter-rater differences were significantly lower for ultrasound volumes compared with caliper volumes (P = .0005 and .001, respectively). Reviewer ICCs for ultrasound and caliper measurements were similarly low (1%), yet caliper volume variance was 1.3-fold higher than for ultrasound. Ultrasound imaging more accurately, precisely, and reproducibly reflects xenograft tumor volume than caliper measurements. These data suggest that preclinical studies using the xenograft burden as a surrogate end point measured by ultrasound imaging require up to 30% fewer animals to reach statistical significance compared with analogous studies using caliper measurements.

  18. Comparison of MRI segmentation techniques for measuring liver cyst volumes in autosomal dominant polycystic kidney disease.

    Science.gov (United States)

    Farooq, Zerwa; Behzadi, Ashkan Heshmatzadeh; Blumenfeld, Jon D; Zhao, Yize; Prince, Martin R

    To compare MRI segmentation methods for measuring liver cyst volumes in autosomal dominant polycystic kidney disease (ADPKD). Liver cyst volumes in 42 ADPKD patients were measured using region growing, thresholding and cyst diameter techniques. Manual segmentation was the reference standard. Root mean square deviation was 113, 155, and 500 for cyst diameter, thresholding and region growing respectively. Thresholding error for cyst volumes below 500ml was 550% vs 17% for cyst volumes above 500ml (p<0.001). For measuring volume of a small number of cysts, cyst diameter and manual segmentation methods are recommended. For severe disease with numerous, large hepatic cysts, thresholding is an acceptable alternative. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Measurement Options for the Assessment of Head Start Quality Enhancements: Final Report. Volume II

    Science.gov (United States)

    Pai-Samant, Shefali; DeWolfe, Joanna; Caverly, Sarah; Boller, Kimberly; McGroder, Sharon; Zettler, Jennifer; Mills, Jessica; Ross, Christine; Clark, Cheryl; Quinones, Mariel; Gulin, Jamie

    2005-01-01

    This volume provides a compendium of measures that could be used to evaluate the effectiveness of Head Start enhancements. The focus is on child outcome measures, although measures pertaining to intermediate outcomes related both to changes in the program and changes in the home are included. The authors also review measures and variables…

  20. Laryngeal tumor volume measurements determined with CT: a study on intra- and interobserver variability

    International Nuclear Information System (INIS)

    Hermans, Robert; Feron, Michel; Bellon, Erwin; Dupont, Patrick; Van den Bogaert, Walter; Baert, Albert L.

    1998-01-01

    Purpose: To investigate the intra- and interobserver variability of computed tomography-based volume measurements of laryngeal tumors. Methods and Materials: The volume of 13 laryngeal tumors was repeatedly measured by five independent observers in four different sessions, using the summation-of-areas technique. Mean tumor volume and its standard deviation were calculated for each tumor. Statistical analysis was done with analysis of variance, Spearman rank correlation, and linear regression. Results: Both the effect of the observers (p < 0.0001) and the effect of the session (p < 0.01) on tumor volume was statistically significant. Interobserver variability was the most important component of total variability (89.3%). A significant rank correlation was found between mean volume and standard deviation (p < 0.01); the relationship between mean tumor volume and standard deviation can be described using linear regression [standard deviation = 0.28 volume + 0.35 (R = 0.79)]. Conclusion: Total variability in the computed tomography-based measurement of laryngeal tumor volume can be reduced by having the measurements done by a single trained observer

  1. Kinetics of thyroid hormones

    International Nuclear Information System (INIS)

    Inada, Mitsuo; Nishikawa, Mitsushige; Naito, Kimikazu; Ishii, Hitoshi; Tanaka, Kiyoshi

    1980-01-01

    Kinetics of thyroid hormones were outlined, and recent progress in metabolism of these hormones was also described. Recently, not only T 4 and T 3 but also rT 3 , 3,3'-T 2 , 3',5'-T 2 , and 3,5-T 2 can be measured by RIA. To clarify metabolic pathways of these hormones, metabolic clearance rate and production rate of these hormones were calculated. As single-compartment analysis was insufficient to clarify disappearance curves of thyroid hormones in blood such as T 3 and T 2 of which metabolic speed was so fast, multi-compartment analysis or non-compartment analysis were also performed. Thyroid hormones seemed to be measured more precisely by constant infusion method. At the first step of T 4 metabolism, T 3 was formed by 5'-monodeiodination of T 4 , and rT 3 was formed by 5-monodeiodination of T 4 . As metabolic pathways of T 3 and rT 3 , conversion of them to 3,3'-T 2 or to 3',5'-T 2 and 3,5-T 2 was supposed. This subject will be an interesting research theme in future. (Tsunoda, M.)

  2. Thyroid carcinoma

    International Nuclear Information System (INIS)

    Friedman, M.; Skolnik, E.M.; Baim, H.M.; Becker, S.P.; Katz, A.H.; Mantravadi, R.V.

    1980-01-01

    Differentiated thyroid carcinoma was studied with regard to mode of presentation, initial findings, treatment and survival. The classic signs, symptoms, physical and scan findings were found to be present in approximately 70% of the patients. Prognosis was found to be dependent on age of presentation more than any other factor. Patients with prior exposure to radiation were found to have more extensive disease and require more extensive surgery but ultimately had the same prognosis for 15-year cure. Treatment for distant metastatic disease by surgery, radioactive iodine and external radiation all resulted in long-term survival in certain cases

  3. Idaho field experiment 1981. Volume 2: measurement data

    Energy Technology Data Exchange (ETDEWEB)

    Start, G E; Sagendorf, J F; Ackermann, G R; Cate, J H; Hukari, N F; Dickson, C R

    1984-04-01

    The 1981 Idaho Field Experiment was conducted in southeastern Idaho over the upper Snake River Plain. Nine test-day case studies were conducted between July 15 and 30, 1981. Releases of SF/sub 6/ gaseous tracer were made for 8-hour periods from 46m above ground. Tracer was sampled hourly, for 12 sequential hours, at about 100 locations within an area 24km square. Also, a single total integrated sample of about 30 hours duration was collected at approximately 100 sites within an area 48 by 72km square (using 6km spacings). Extensive tower profiles of meteorology at the release point were collected. RAWINSONDES, RABALS and PIBALS were collected at 3 to 5 sites. Horizontal, low-altitude winds were monitored using the INEL MESONET. SF/sub 6/ tracer plume releases were marked with co-located oil fog releases and bi-hourly sequential launches of tetroon pairs. Aerial LIDAR observations of the oil fog plume and airborne samples of SF/sub 6/ were collected. High altitude aerial photographs of daytime plumes were collected. Volume II lists the data in tabular form or cites the special supplemental reports by other participating contractors. While the primary user file and the data archive are maintained on 9 track/1600 cpi magnetic tapes, listings of the individual values are provided for the user who either cannot utilize the tapes or wishes to preview the data. The accuracies and quality of these data are described.

  4. Thyroiditis: an integrated approach.

    Science.gov (United States)

    Sweeney, Lori B; Stewart, Christopher; Gaitonde, David Y

    2014-09-15

    Thyroiditis is a general term that encompasses several clinical disorders characterized by inflammation of the thyroid gland. The most common is Hashimoto thyroiditis; patients typically present with a nontender goiter, hypothyroidism, and an elevated thyroid peroxidase antibody level. Treatment with levothyroxine ameliorates the hypothyroidism and may reduce goiter size. Postpartum thyroiditis is transient or persistent thyroid dysfunction that occurs within one year of childbirth, miscarriage, or medical abortion. Release of preformed thyroid hormone into the bloodstream may result in hyperthyroidism. This may be followed by transient or permanent hypothyroidism as a result of depletion of thyroid hormone stores and destruction of thyroid hormone-producing cells. Patients should be monitored for changes in thyroid function. Beta blockers can treat symptoms in the initial hyperthyroid phase; in the subsequent hypothyroid phase, levothyroxine should be considered in women with a serum thyroid-stimulating hormone level greater than 10 mIU per L, or in women with a thyroid-stimulating hormone level of 4 to 10 mIU per L who are symptomatic or desire fertility. Subacute thyroiditis is a transient thyrotoxic state characterized by anterior neck pain, suppressed thyroid-stimulating hormone, and low radioactive iodine uptake on thyroid scanning. Many cases of subacute thyroiditis follow an upper respiratory viral illness, which is thought to trigger an inflammatory destruction of thyroid follicles. In most cases, the thyroid gland spontaneously resumes normal thyroid hormone production after several months. Treatment with high-dose acetylsalicylic acid or nonsteroidal anti-inflammatory drugs is directed toward relief of thyroid pain.

  5. Diagnostic Frequency Ratios Are Insufficient to Measure Laboratory Precision with The Bethesda System for Reporting Thyroid Cytopathology.

    Science.gov (United States)

    Fazeli, Roghayeh; Schneider, Eric B; Ali, Syed Z; Zeiger, Martha A; Olson, Matthew T

    2015-01-01

    Diagnostic frequency ratios such as the atypia of undetermined significance (AUS):malignant ratio are touted to be useful for laboratory precision benchmarking. We therefore sought to examine their reproducibility and usefulness at a tertiary hospital. We reviewed thyroid fine-needle aspirates (FNA) submitted to our institution from outside laboratories and evaluated the ability of diagnostic frequency ratios to capture the complexity of The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC). Specifically, we evaluated the ability of the AUS:malignant ratio to describe the frequencies of the other TBSRTC diagnoses. A total of 2,784 cases from 19 laboratories were included. The use of the AUS category varied the most. There was insufficient reflection of the non-AUS nonmalignant TBSRTC diagnostic frequencies in our analysis, and these results do not appear to arise from observer variability in the outside laboratories. Diagnostic frequency ratios are not reproducible in our experience and fail to describe the other TBSRTC categories. As such, they are unlikely to prove sufficient for benchmarking laboratory precision with TBSRTC. © 2015 S. Karger AG, Basel.

  6. correlation between cytology and thyroid function test

    African Journals Online (AJOL)

    Damary

    2006-10-01

    Oct 1, 2006 ... Background: Thyroid dysfunction can be evaluated by measuring serum thyroid stimulating hormone (TSH), total tri-iodothyronine (T3) and total thyroxine (T4) which will establish euthyroidism, hyperthyroidism and hypothyroidism. Fine needle aspiration (FNA) is the diagnostic test of choice in determining ...

  7. Metopic synostosis: Measuring intracranial volume change following fronto-orbital advancement using three-dimensional photogrammetry.

    Science.gov (United States)

    Freudlsperger, Christian; Steinmacher, Sahra; Bächli, Heidi; Somlo, Elek; Hoffmann, Jürgen; Engel, Michael

    2015-06-01

    There is still disagreement regarding the intracranial volumes of patients with metopic synostosis compared with healthy patients. This study aimed to compare the intracranial volume of children with metopic synostosis before and after surgery to an age- and sex-matched control cohort using three-dimensional (3D) photogrammetry. Eighteen boys with metopic synostosis were operated on using standardized fronto-orbital advancement. Frontal, posterior and total intracranial volumes were measured exactly 1 day pre-operatively and 10 days post-operatively, using 3D photogrammetry. To establish an age- and sex-matched control group, the 3D photogrammetric data of 634 healthy boys between the ages of 3 and 13 months were analyzed. Mean age at surgery was 9 months (SD 1.7). Prior to surgery, boys with metopic synostosis showed significantly reduced frontal and total intracranial volumes compared with the reference group, but similar posterior volumes. After surgery, frontal and total intracranial volumes did not differ statistically from the control group. As children with metopic synostosis showed significantly smaller frontal and total intracranial volumes compared with an age- and sex-matched control group, corrective surgery should aim to achieve volume expansion. Furthermore, 3D photogrammetry provides a valuable alternative to CT scans in the measurement of intracranial volume in children with metopic synostosis, which significantly reduces the amount of radiation exposure to the growing brain. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Measurement of liver and spleen volume by computed tomography using point counting technique

    International Nuclear Information System (INIS)

    Matsuda, Yoshiro; Sato, Hiroyuki; Nei, Jinichi; Takada, Akira

    1982-01-01

    We devised a new method for measurement of liver and spleen volume by computed tomography using point counting technique. This method is very simple and applicable to any kind of CT scanner. The volumes of the livers and spleens estimated by this method were significantly correlated with the weights of the corresponding organs measured on autopsy or surgical operation, indicating clinical usefulness of this method. Hepatic and splenic volumes were estimated by this method in 43 patients with chronic liver disease and 9 subjects with non-hepatobiliary disease. The mean hepatic volume in non-alcoholic liver cirrhosis was significantly smaller than those in non-hepatobiliary disease and other chronic liver diseases. The mean hepatic volume in alcoholic cirrhosis and alcoholic fibrosis tended to be slightly larger than that in non-hepatobiliary disease. The mean splenic volume in liver cirrhosis was significantly larger than those in non-hepatobiliary disease and other chronic liver diseases. However, there was no significant difference of the mean splenic volume between alcoholic and non-alcoholic cirrhosis. Significantly positive correlation between hepatic and splenic volumes was found in alcoholic cirrhosis, but not in non-alcoholic cirrhosis. These results indicate that estimation of hepatic and splenic volumes by this method is useful for the analysis of the pathophysiological condition of chronic liver diseases. (author)

  9. Nasopharyngeal carcinoma volume measurements determined with computed tomography: study of intraobserver and interobserver variability.

    Science.gov (United States)

    Chang, Cheng-Chuan; Chen, Mu-Kuan; Wu, Hwa-Koon; Liu, Mu-Tai

    2002-12-01

    To investigate the intraobserver and interobserver variability of computed tomography-based volume measurements of nasopharyngeal carcinoma. Prospective study. Tertiary care centre. The primary tumour volume of 13 nasopharyngeal carcinomas was repeatedly measured by two trained observers independently in two different sessions, using the summation of area technique. Mean tumour volume and its standard deviation were calculated for each tumour. Statistical analysis was done with multivariate analysis, linear regression, and a two-way analysis of variance (ANOVA) random effects model. The coefficient of variation was less than 20% in 11 volume measurements, but a large discrepancy between observers was noted in two tumours with involvement of the paranasal sinuses. A good linear correlation was found between mean tumour volume and its standard deviation: standard deviation = 0.26 volume - 2.48 (r = .80). When the two tumours with a large coefficient of variation were excluded, the two-way ANOVA random effects model revealed that both the interobserver (p = .83) and the intraobserver (p = .90) effect are not statistically significant; interobserver variability was the major component of total variability (71.0%). Total variability in the computed tomography-based measurement of nasopharyngeal carcinoma volume is small by having the measurements done by a trained observer, except in tumours with involvement of the paranasal sinuses.

  10. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    Ethical approval was obtained from the Ethics Review Board of Aminu Kano Teaching. Hospital in 2011. One hundred subjects were recruited into the study after administration and ... The system has an inbuilt algorithm to generate the measured parameters. The findings were saved on the system and printed copies made.

  11. Urban Run-off Volumes Dependency on Rainfall Measurement Method

    DEFF Research Database (Denmark)

    Pedersen, L.; Jensen, N. E.; Rasmussen, Michael R.

    2005-01-01

    suggests that rainfall needs to be measured with a much higher spatial resolution (Jensen and Pedersen, 2004). This paper evaluates the impact of using high-resolution rainfall information from weather radar compared to the conventional single gauge approach. The radar rainfall in three different...

  12. Automatic measurement of orbital volume in unilateral coronal synostosis

    DEFF Research Database (Denmark)

    Dahl, Vedrana Andersen; Einarsson, Gudmundur; Darvann, Tron Andre

    2016-01-01

    . These measures are typically computed by guided procedures that require expert time. We propose a method with higher degree of automation based on finding an optimal smooth closed surface. CT scans of 17 infants with UCS are included in our experimental validation, where we compare our method to expert guided...

  13. A technique for fast and accurate measurement of hand volumes using Archimedes' principle.

    Science.gov (United States)

    Hughes, S; Lau, J

    2008-03-01

    A new technique for measuring hand volumes using Archimedes principle is described. The technique involves the immersion of a hand in a water container placed on an electronic balance. The volume is given by the change in weight divided by the density of water. This technique was compared with the more conventional technique of immersing an object in a container with an overflow spout and collecting and weighing the volume of overflow water. The hand volume of two subjects was measured. Hand volumes were 494 +/- 6 ml and 312 +/- 7 ml for the immersion method and 476 +/- 14 ml and 302 +/- 8 ml for the overflow method for the two subjects respectively. Using plastic test objects, the mean difference between the actual and measured volume was -0.3% and 2.0% for the immersion and overflow techniques respectively. This study shows that hand volumes can be obtained more quickly than the overflow method. The technique could find an application in clinics where frequent hand volumes are required.

  14. Computer Assisted Data Analysis in the Dye Dilution Technique for Plasma Volume Measurement.

    Science.gov (United States)

    Bishop, Marvin; Robinson, Gerald D.

    1981-01-01

    Describes a method for undergraduate physiology students to measure plasma volume by the dye dilution technique, in which a computer is used to interpret data. Includes the computer program for the data analysis. (CS)

  15. Methodological appraisal of SPECT measurements of cerebral blood volume and cerebral tissue hematocrit. Chapter 25

    International Nuclear Information System (INIS)

    Sakai, Fumihiko

    1988-01-01

    In this communication a critical appraisal is given of the method for measuring cerebral blood volume (CBV) and cerebral hematocrit employing single-photon emission computed tomography (SPECT). 2 refs

  16. Measurement of gastric meal and secretion volumes using magnetic resonance imaging

    Science.gov (United States)

    Hoad, C. L.; Parker, H.; Hudders, N.; Costigan, C.; Cox, E. F.; Perkins, A. C.; Blackshaw, P. E.; Marciani, L.; Spiller, R. C.; Fox, M. R.; Gowland, P. A.

    2015-02-01

    MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean ± SD coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3  ±  2% at large gastric volumes (>200 ml). Mean ± SD secretion volumes post meal ingestion were 64  ±  51 ml and 110  ±  40 ml at 15 and 75 min, respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient ± std err of 1.06  ±  0.10 and intercept -11  ±  24 ml. In conclusion, (i) rapid volume acquisition and respiratory triggered T1 mapping removed the requirement to image during prolonged breath-holds (ii) semi-automatic analysis greatly reduced the time required to derive measurements and (iii) correction for secretion volumes provided accurate assessment of gastric meal volumes and emptying. Together these features

  17. Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology?

    Directory of Open Access Journals (Sweden)

    Baldini Enke

    2013-02-01

    Full Text Available Abstract Background Measurement of thyroglobulin (Tg protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN metastasis from well-differentiated thyroid cancer (TC. In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp, Tg mRNA (FNAB-Tgm and calcitonin (CT mRNA (FNAB-CTm in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC in 26 CLN, metastatic medullary TC (MTC in 3 CLN, metastatic anaplastic TC (ATC in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters.

  18. Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology?

    Science.gov (United States)

    2013-01-01

    Background Measurement of thyroglobulin (Tg) protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C) has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN) metastasis from well-differentiated thyroid cancer (TC). In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp), Tg mRNA (FNAB-Tgm) and calcitonin (CT) mRNA (FNAB-CTm) in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC) in 26 CLN, metastatic medullary TC (MTC) in 3 CLN, metastatic anaplastic TC (ATC) in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters. PMID:23421519

  19. Clinical evaluation of echography in diagnosis of thyroid disease

    International Nuclear Information System (INIS)

    Fritzsche, H.; Braendle, J.

    1983-01-01

    In 63 patients echography of thyroid was performed additionally to case history, palpation, scintigraphy and hormone tests for evaluating clinical significance of this method. The benefit of this technique is rapid measurement of thyroid size, demonstration of nodules in palpable diffuse goiters and differentiating of solid or cystic nodules of the thyroid. For diagnosis of autonomous areas in the thyroid scintigrahy remains the method of choice. Also there is no correlation of ultrasound findings and thyroid function. In routine diagnostic procedure of thyroid disease echography may replace scintigraphy only in diffuse goiter and if radionuclide imaging is not possible. Nevertheless ultrasonic evaluation of the thyroid is an important additional method in diagnostic of thyroid diseases. (Author)

  20. High frequency of positive anti-thyroid peroxidase antibodies (ATPO) in adult subjects without known thyroid disease, Santiago de Chile

    International Nuclear Information System (INIS)

    Lanas, Alejandra; Letelier, Carolina; Caamano, Edgardo; Massardo, Teresa; Gonzalez, Patricio; Araya, Veronica

    2010-01-01

    Background: Anti-thyroid peroxidase antibodies have a pathogenic role in Hashimoto thyroiditis. Between 10 and 19% of individuals without thyroid disease, have positive titers of these antibodies. Aim: To study the frequency of positive titers of anti-thyroid peroxidase antibodies in healthy individuals. Material and Methods: A blood sample, to measure anti-thyroid peroxidase antibodies and thyroid stimulating hormone (TSH) by chemiluminescence assay, was obtained from 67 women and 62 men aged 45 ± 14 years, without a personal or familiar history of thyroid diseases and normal thyroid palpation. The cutoff point of the manufacturer to consider positive a titer of anti-thyroid peroxidase antibodies was set at 35 IU/ml. Results: Twenty-eight women and 28 men had positive antibody titers (43% of the sample). Subjects in the upper tercile of anti-thyroid peroxidase antibody titers had a higher TSH than those in the second tercile, although within normal limits (1.73 ± 0.74 and 1.37 ± 0.59 mlU/L, respectively p = 0.02) Conclusions: Forty three percent of the studied subjects without personal or familial history of thyroid diseases had positive titers of anti-thyroid peroxidase antibodies. Further prospective studies should evaluate whether this observation discloses an increase in thyroid autoimmune disease in a population with increased iodine intake

  1. Radiation and thyroid neoplasia

    International Nuclear Information System (INIS)

    McConahey, W.M.; Hayles, A.B.

    1976-01-01

    It is now generally accepted that an association exists between external radiation administered to the head, neck, and upper thorax of infants, children, and adolescents and the subsequent development of neoplastic changes in the thyroid gland. Until recent years, external radiation was frequently administered to shrink an enlarged thymus or for the treatment of tonsillitis, adenoiditis, hearing loss, hemangioma, acne, tinea capitis, and other conditions. During the course of these treatments, the thyroid gland was exposed to scatter radiation. The use of external radiation therapy was then accepted practice, and its value was attested by many. Concern about the adverse effects was not initially appreciated, primarily because of the long periods of time between the radiation and the recognition of changes in the thyroid. The availability and effectiveness of other therapeutic measures and the growing concern about the delayed effects of radiation therapy when administered to the young for relatively benign conditions has, in recent years, largely eliminated use of this form of therapy, except in a few unusual conditions

  2. Measuring the volume of uterine fibroids using 2- and 3-dimensional ultrasound and comparison with histopathology.

    Science.gov (United States)

    Zivković, Nikica; Zivković, Kreiimir; Despot, Albert; Paić, Josip; Zelić, Ana

    2012-12-01

    The aim of this study was clinical testing of the reliability and usability of three-dimensional (3D) and two-dimensional (2D) ultrasound (US) technology. The ultimate aim and purpose of this study was to establish ultrasound methods, standards and protocols for determining the volume of any gynecologic organ or tumor. The study included 31 women in reproductive age and postmenopause. All patients were examined with a RIC 5-9 3D-endovaginal probe (4.3-7.5 MHz) on a Voluson 730 Pro ultrasound device. The volume of myomas was measured by using the existing 2D and 3D ultrasound methods on the above mentioned device. All patients underwent myomectomy or hysterectomy due to clinically and ultrasonographically diagnosed uterine myomas indicating operative intervention. After the operation, the pathologist determined the volume of removed myomas by measuring them in a gauge bowl containing water, i.e. using Archimedes' principle (lift), serving as the control group with histopathologic diagnosis. A total of 155 myoma volumes were processed on 2D display, 31 myoma volumes were preoperatively measured on 3D display and 31 myoma volumes were measured by the pathologist. The values of US measurements for each US method were expressed as mean value of all measurements of myoma volumes. Statistical processing of the results and Student's t-test for independent samples revealed that the 2nd examined US method (measuring of myoma by using an ellipse and the longer tumor diameter) and 4th examined US method (measuring of myoma by using the longer and shorter tumor diameters together with establishing their mean values) in 2D US technique, as well as the 6th examined US method in 3D US technique showed no significant measurement differences in comparison with control measurement in a gauge bowl containing water (p < 0.05), indicating acceptability of the US methods for verifying tumor volumes. The standard error in determining the volume of myomas by the above US methods varied

  3. Salt iodization in Denmark and individual changes in thyroid size, thyroid nodularity and serum thyroglobulin

    DEFF Research Database (Denmark)

    Krejbjerg, Anne

    in the year 2000. A monitoring program entitled the Danish Investigation on Iodine Intake and Thyroid Diseases (DanThyr) was initiated before any iodization of salt had begun to improve knowledge on how to evaluate iodine status in a population and to study the effects of an increase in iodine intake. The aim......Iodine is an essential mineral for the synthesis of thyroid hormones. Low iodine intake levels are associated with goitre and other iodine deficiency-related disorders that have affected billions of people worldwide. Until recently the iodine intake of many European populations was below...... of this PhD thesis was to evaluate individual changes in thyroid related variables associated with iodine fortification. We chose thyroid volume, thyroid nodularity and serum thyroglobulin as indicators of impact and evaluated possible changes in an 11-year follow-up investigation performed before and after...

  4. A remark on the infinite-volume Gibbs measures of spin glasses

    Science.gov (United States)

    Arguin, Louis-Pierre

    2008-12-01

    In this note, we point out that infinite-volume Gibbs measures of spin glass models on the hypercube can be identified as random probability measures on the unit ball of a Hilbert space. This simple observation follows from a result of Dovbysh and Sudakov on weakly exchangeable random matrices. Limiting Gibbs measures can then be studied as single well-defined objects. This approach naturally extends the space of random overlap structures as defined by Aizenman et al. We discuss the Ruelle probability cascades and the stochastic stability within this framework. As an application, we use an idea of Parisi and Talagrand to prove that if a sequence of finite-volume Gibbs measures satisfies the Ghirlanda-Guerra identities, then the infinite-volume measure must be singular as a measure on a Hilbert space.

  5. Ultrasound of the Thyroid Gland

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound - Thyroid Thyroid ultrasound uses sound waves to produce pictures ... the Thyroid? What is an Ultrasound of the Thyroid? Ultrasound is safe and painless, and produces pictures ...

  6. Detection system qualification for direct measurement of thyroid internal contamination by radioiodine; Qualificazione di un sistema di rilevazione trasportabile per misure dirette di contaminazione interna di radioiodio

    Energy Technology Data Exchange (ETDEWEB)

    Tiberi, V.; Battisti, P.; Gualdrini, G. [ENEA, Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1999-07-01

    The work deals with a detection system qualification for direct measurements of thyroid internal contamination by radioiodine. The isotopes {sup 131}I and {sup 125}I are the most frequently used in nuclear medicine. Because of their volatility they are very dangerous for thyroid contamination by inhalation. The system has been projected to be easily and fast used and above all transportable where the control is necessary. These characteristic make it able to realise supervision programs of internal contamination by radioiodine. In fact due the very high control frequencies (each 15 days for {sup 131}I), these programs are usually very expensive and demanding when they are executed in external measurement laboratories. The following steps are described: devices presentation, calculation of energy and efficiency parameters, minimum detectable activity, time system reliability, best operative conditions in the measurements. At the end an application example of the system is reported. [Italian] Il presente lavoro consiste nella qualificazione di un sistema di rivelazione per misure dirette di contaminazione interna da radioiodio in tiroide, progettato per essere maneggevole, di semplice e rapido impiego e trasportabile sul luogo dove e' richiesta la misura. Il sistema e' stato studiato per la realizzazione di programmi di sorveglianza della contaminazione interna da radioiodio che, richiedendo frequenze di controllo elevate (quindicinali per lo {sup 131}I), sono estremamente impegnativi ed onerosi, soprattutto se i controlli vengono effettuati in centri di misura esterni. Dopo la determinazione dei parametri della calibrazione in energia ed efficienza, la minima attivita' rivelabile, l'affidabilita' del sistema nel tempo e le condizioni operative ottimali da adottare in sede di misura, viene verificata la piena affidabilita' del sistema in un programma di sorveglianza della contaminazione interna da radioiodio.

  7. Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mori, Koichi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute and MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5 T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI. (author)

  8. [Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging].

    Science.gov (United States)

    Mori, Koichi; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute an MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI.

  9. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  10. Shear wave velocity of the healthy thyroid gland in children with acoustic radiation force impulse elastography.

    Science.gov (United States)

    Ceyhan Bilgici, Meltem; Sağlam, Dilek; Delibalta, Semra; Yücel, Serap; Tomak, Leman; Elmalı, Muzaffer

    2018-01-01

    Acoustic radiation force impulse imaging is a kind of shear wave elastography that can be used in children for differentiating thyroid pathologies. Possible changes in the healthy thyroid gland in children may create difficulties in the use of shear wave velocities (SWV) in thyroid pathologies. The aim of this study was to define the normal values of SWV for the healthy thyroid gland in children, elucidate the correlation of the SWV values with potential influencing factors, and evaluate intra-operator reproducibility of the SWV. Between January 2015 and December 2015, a total of 145 healthy children (81 girls, 64 boys; mean age, 10.5 ± 3.14 years; range 6-17 years) were enrolled in the study. The SWV and volume of the thyroid gland were determined. The mean shear wave velocity of the thyroid gland was 1.22 ± 0.20 m/s. There was no correlation between age and the mean SWV of the thyroid gland (Spearman Rho = 0.049, p = 0.556). There was also no correlation between the thyroid gland volume or BSA and the mean SWV. The only correlation detected was between BSA and total thyroid gland volume (p thyroid gland in children was determined. There was no correlation between the SWV of the thyroid gland and age, BSA, or thyroid gland volume.

  11. Measurement of lung volume by lung perfusion scanning using SPECT and prediction of postoperative respiratory function

    International Nuclear Information System (INIS)

    Andou, Akio; Shimizu, Nobuyosi; Maruyama, Shuichiro

    1992-01-01

    Measurement of lung volume by lung perfusion scanning using single photon emission computed tomography (SPECT) and its usefulness for the prediction of respiratory function after lung resection were investigated. The lung volumes calculated in 5 patients by SPECT (threshold level 20%) using 99m Tc-macroaggregated albumin (MAA), related very closely to the actually measured lung volumes. This results prompted us to calculate the total lung volume and the volume of the lobe to be resected in 18 patients with lung cancer by SPECT. Based on the data obtained, postoperative respiratory function was predicted. The predicted values of forced vital capacity (FVC), forced expiratory volume (FEV 1.0 ), and maximum vital volume (MVV) showed closer correlations with the actually measured postoperative values (FVC, FEV 1.0 , MVV : r=0.944, r=0.917, r=0.795 respectively), than the values predicted by the ordinary lung perfusion scanning. This method facilitates more detailed evaluation of local lung function on a lobe-by-lobe basis, and can be applied clinically to predict postoperative respiratory function. (author)

  12. Self-Interaction Chromatography of mAbs: Accurate Measurement of Dead Volumes.

    Science.gov (United States)

    Hedberg, S H M; Heng, J Y Y; Williams, D R; Liddell, J M

    2015-12-01

    Measurement of the second virial coefficient B22 for proteins using self-interaction chromatography (SIC) is becoming an increasingly important technique for studying their solution behaviour. In common with all physicochemical chromatographic methods, measuring the dead volume of the SIC packed column is crucial for accurate retention data; this paper examines best practise for dead volume determination. SIC type experiments using catalase, BSA, lysozyme and a mAb as model systems are reported, as well as a number of dead column measurements. It was observed that lysozyme and mAb interacted specifically with Toyopearl AF-Formyl dead columns depending upon pH and [NaCl], invalidating their dead volume usage. Toyopearl AF-Amino packed dead columns showed no such problems and acted as suitable dead columns without any solution condition dependency. Dead volume determinations using dextran MW standards with protein immobilised SIC columns provided dead volume estimates close to those obtained using Toyopearl AF-Amino dead columns. It is concluded that specific interactions between proteins, including mAbs, and select SIC support phases can compromise the use of some standard approaches for estimating the dead volume of SIC columns. Two other methods were shown to provide good estimates for the dead volume.

  13. Quantitative assessment of thyroid gland elasticity with shear-wave elastography in pediatric patients with Hashimoto's thyroiditis.

    Science.gov (United States)

    Kandemirli, Sedat Giray; Bayramoglu, Zuhal; Caliskan, Emine; Sari, Zeynep Nur Akyol; Adaletli, Ibrahim

    2018-01-18

    Hashimoto's thyroiditis is the most common autoimmune thyroid disorder in the pediatric age range. Measurement of thyroid gland size is an essential component in evaluation and follow-up of thyroid pathologies. Along with size, tissue elasticity is becoming a more commonly used parameter in evaluation of parenchyma in inflammatory diseases. The aim of the current study was to assess thyroid parenchyma elasticity by shear-wave elastography in pediatric patients with Hashimoto's thyroiditis; and compare the elasticity values to a normal control group. In this study; thyroid glands of 59 patients with a diagnosis of Hashimoto's thyroiditis based on ultrasonographic and biochemical features, and 26 healthy volunteers without autoimmune thyroid disease and thyroid function disorders, were evaluated with shear-wave elastography. Patients with Hashimoto thyroiditis were further subdivided into three categories based on gray-scale ultrasonography findings as focal thyroiditis (grade 1), diffuse thyroiditis (grade 2), and fibrotic thyroid gland (grade 3). Patients with Hashimoto's thyroiditis (n = 59) had significantly higher elasticity values (14. 9 kPa; IQR 12.9-17.8 kPa) than control subjects (10.6 kPa; IQR 9.0-11.3 kPa) (p thyroiditis, 23 patients had focal thyroiditis involving less than 50% of the gland categorized as grade 1, 24 patients had diffuse involvement of the thyroid gland categorized as grade 2, and 12 patients had marked hyperechoic septations and pseudonodular appearance categorized as grade 3 on gray-scale ultrasound. Based on elastography, grade 3 patients had significantly higher elasticity values (19.7 kPa; IQR 17.8-21.5 kPa) than patients with grade 2 (15.5 kPa; IQR 14.5-17.8 kPa) and grade 1 thyroiditis (12.8 kPa; IQR 11.9-13.1 kPa) (p thyroiditis had significantly higher elasticity values than those with grade 1 thyroiditis (p thyroiditis. Our results indicate that shear-wave elastography could be used to evaluate the degree of

  14. Comparison of M22-based ELISA and human-TSH-receptor-based luminescence assay for the measurement of thyrotropin receptor antibodies in patients with thyroid diseases.

    Science.gov (United States)

    Liu, C; Hermsen, D; Domberg, J; Graeber, C; Hautzel, H; Duan, Y; Xu, K F; Liu, C P; Mao, X D; Cupisti, K; Scherbaum, W A; Schott, M

    2008-07-01

    Previously, a new procedure for measuring serum TSH receptor autoantibodies (TRAb) was reported in which the autoantibodies inhibit binding of a human monoclonal thyroid stimulating antibody M22 to TSHR-coated ELISA plate wells (TRAb ELISA). The aim of the present study was to evaluate the clinical performance of this assay in comparison to the second generation TRAb assay (TRAb LIA) based on the recombinant human TSH-receptor and chemiluminescence technology (TRAb LIA). Among the 158 patients, 84 patients suffered from Graves' disease (GD), 34 patients had Hashimoto's thyroiditis (HT), and 40 patients had euthyroid nodular thyroid disease (NTD) without signs of autoimmunity. TRAb measurements were performed according to the manufacturer's instructions. Out of 84 GD patients, 80 (95.2%) were TRAb positive as detected by the TRAb LIA. One GD patient had TRAb values within the grey zone (1.0-1.5 IU/l). All patients with HT and NTD were negative except in 6 (8.1%) cases whose TRAb values were within the grey zone. On the basis of the recommended cutoff value (TRAb 1.0 IU/l), the TRAb ELISA found 78 of 84 (92.9%) GD patients to be TRAb positive. None of the patients with HT, but two cases (5.0%) with NTD were TRAb positive. The diagnostic sensitivity of the TRAb LIA and TRAb ELISA assays was 95.2 and 92.9%, while the specificity was 100% and 97.3%, respectively. There was a close correlation (r=0.968, pvalue of 1.0 IU/l. Due to the evaluated imprecision data we propose a higher cutoff value correlating with a between-run CV of 20% (functional assay sensitivity). Our results indicate that due to a worse imprecision the TRAb ELISA has a slightly lower sensitivity and specificity compared to the TRAb LIA assay. These findings suggest that the M22 monoclonal antibody-based TRAb ELISA is not as reliable as other second generation TRAb assays in the diagnosis of Graves' diseases.

  15. Thyroid diseases after Chernobyl accident

    International Nuclear Information System (INIS)

    Nagataki, Shigenobu

    1993-01-01

    Radioactive iodine is released at every atomic-bomb testings and nuclear plants accidents and radioactive iodine is taken up by thyroid glands (internal radiation). In addition to the internal radiation, radioactive fallout causes the external radiation and thyroid glands are known to be sensitive to the external radiation. Furthermore, patients with radiation-induced thyroid disease can survive for a long time regardless of the treatment. The survey of thyroid diseases, therefore, is very sensitive and reliable ways to investigate the effects of radiation caused by atomic bomb explosion, testing and various types of nuclear plants' accidents. Our group from Nagasaki University was asked to investigate the thyroid diseases and jointed to the Sasakawa Project. In order to investigate the effects of radiation on thyroid disease, it is essential 1) to make a correct diagnosis in each subject, 2) to calculate a correct radiation dose in each subject and finally, 3) to find out the correlation between the radiation dose and thyroid diseases including age-, sex- and area-matched controls. We have established 5 centers (1 in Russia, 2 in Belarus, 2 in Ukraine) and supplied the most valuable ultrasonography instruments, commercial kits for the determination of serum free T 4 and TSH level and for the autoantibodies, instrument for urinary iodine measurements, syringers, tubes, refrigerators, etc. We visit each center often and asked people at centers to come to Japan for training. Protocol of investigation is essentially the same as that in Nagasaki, and we are planning to investigate more than 50,000 children within 5 years. We are hoping to show a definite conclusion in the near future. Recent articles are also discussed. (author)

  16. The role of thyroid scanning in hyperthyroidism

    International Nuclear Information System (INIS)

    Fogelman, I.; Cooke, S.G.; Maisey, M.N.

    1986-01-01

    Radionuclide thyroid imaging was performed in 872 consecutive patients with hyperthyroidism. Of these, 84% were found to have diffuse toxic hyperplasia (Graves' disease), while 12% had autonomously functioning nodules (Plummer's disease), 3% had Graves' disease developing in a multinodular gland, and in the remaining 1%, either a clear diagnosis could not be established or the hyperthyroidism was due to thyroiditis or the Jod-Basedow phenomenon. It was found that a thyroid scan seldom provides additional diagnostic information in patients with Graves' disease when a diffuse goitre is present. However, if patients are to be treated with radioiodine ( 131 I), thyroid imaging with tracer quantitation can replace a 24-h 131 I uptake measurement, this having the advantages that the patients are required to attend only once, and that the gland size can be measured. In addition, visual confirmation of tracer uptake by the thyroid is obtained and patients with thyroiditis will not receive inappropriate therapy. When single or multiple thyroid nodules are palpated, a thyroid scan is crucial in establishing an accurate diagnosis, as it is not otherwise possible to differentiate between Plummer's disease and Graves' disease developing in a multinodular gland. Indeed, in 20 of our 63 patients (32%) with single autonomously functioning nodules, the initial clinical assessment had been incorrect. (orig.)

  17. The Thyroid-Related Quality of Life Measure ThyPRO Has Good Responsiveness and Ability to Detect Relevant Treatment Effects

    DEFF Research Database (Denmark)

    Watt, Torquil; Cramon, Per; Hegedüs, Laszlo

    2014-01-01

    BACKGROUND AND PURPOSE: Patient-reported outcomes have become important endpoints in comparative effectiveness research and in patient-centered health care. Valid patient-reported outcome measures detect and respond to clinically relevant changes. The purpose of this study was to evaluate......PRO and SF-36 Health Survey (Version 2) at baseline and 6 months after treatment initiation. Responsiveness was evaluated in three thyroid patient groups: patients with hyperthyroidism (n = 66) and hypothyroidism (n = 84) rendered euthyroid after medical therapy, and patients with a clinically detectable...... nontoxic goiter treated with surgery or radioactive iodine and remaining euthyroid (n = 62). Changes in QoL were evaluated in terms of effect size and compared to the changes predicted by clinical experts. The responsiveness of equivalent scales from ThyPRO and SF-36 Health Survey were compared...

  18. Lean body mass as a determinant of thyroid size

    NARCIS (Netherlands)

    Wesche, M. F.; Wiersinga, W. M.; Smits, N. J.

    1998-01-01

    Males have a larger thyroid gland than females, and this has been related to the difference in body weight. In view of the different body composition of men and women, we hypothesized that lean body mass is a better determinant of thyroid volume than body weight. A cross-sectional study in an area

  19. Volume of Structures in the Fetal Brain Measured with a New Semiautomated Method.

    Science.gov (United States)

    Ber, R; Hoffman, D; Hoffman, C; Polat, A; Derazne, E; Mayer, A; Katorza, E

    2017-11-01

    Measuring the volume of fetal brain structures is challenging due to fetal motion, low resolution, and artifacts caused by maternal tissue. Our aim was to introduce a new, simple, Matlab-based semiautomated method to measure the volume of structures in the fetal brain and present normal volumetric curves of the structures measured. The volume of the supratentorial brain, left and right hemispheres, cerebellum, and left and right eyeballs was measured retrospectively by the new semiautomated method in MR imaging examinations of 94 healthy fetuses. Four volume ratios were calculated. Interobserver agreement was calculated with the intraclass correlation coefficient, and a Bland-Altman plot was drawn for comparison of manual and semiautomated method measurements of the supratentorial brain. We present normal volumetric curves and normal percentile values of the structures measured according to gestational age and of the ratios between the cerebellum and the supratentorial brain volume and the total eyeball and the supratentorial brain volume. Interobserver agreement was good or excellent for all structures measured. The Bland-Altman plot between manual and semiautomated measurements showed a maximal relative difference of 7.84%. We present a technologically simple, reproducible method that can be applied prospectively and retrospectively on any MR imaging protocol, and we present normal volumetric curves measured. The method shows results like manual measurements while being less time-consuming and user-dependent. By applying this method on different cranial and extracranial structures, anatomic and pathologic, we believe that fetal volumetry can turn from a research tool into a practical clinical one. © 2017 by American Journal of Neuroradiology.

  20. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    International Nuclear Information System (INIS)

    Furuta, Minoru

    2000-01-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm 3 : this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6±2.0 (mean±standard deviation) cm 3 in males and 20.9±1.3 cm 3 in females. (author)

  1. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Minoru [Fukushima Medical Coll. (Japan)

    2000-10-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm{sup 3}: this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6{+-}2.0 (mean{+-}standard deviation) cm{sup 3} in males and 20.9{+-}1.3 cm{sup 3} in females. (author)

  2. Dose selection for radioiodine therapy of borderline hyperthyroid patients according to thyroid uptake of 99mTc-pertechnetate: applicability to unifocal thyroid autonomy?

    International Nuclear Information System (INIS)

    Reinhardt, Michael J.; Joe, Alexius Y.; Biermann, Kim; Brockmann, Holger; Mallek, Dirk von; Ezziddin, Samer; Wissmeyer, Michael; Juengling, Freimut D.; Krause, Thomas M.

    2006-01-01

    The aim of this study was to evaluate the feasibility of applying a previously described dose strategy based on 99m Tc-pertechnetate thyroid uptake under thyrotropin suppression (TcTU s ) to radioiodine therapy for unifocal thyroid autonomy. A total of 425 consecutive patients (302 females, 123 males; age 63.1±10.3 years) with unifocal thyroid autonomy were treated at three different centres with 131 I, using Marinelli's formula for calculation of three different absorbed dose schedules: 100-300 Gy to the total thyroid volume according to the pre-treatment TcTU s (n=146), 300 Gy to the nodule volume (n=137) and 400 Gy to the nodule volume (n=142). Successful elimination of functional thyroid autonomy with either euthyroidism or hypothyroidism occurred at a mean of 12 months after radioiodine therapy in 94.5% of patients receiving 100-300 Gy to the thyroid volume, in 89.8% of patients receiving 300 Gy to the nodule volume and in 94.4% receiving 400 Gy to the nodule volume. Reduction in thyroid volume was highest for the 100-300 Gy per thyroid and 400 Gy per nodule strategies (36±19% and 38±20%, respectively) and significantly lower for the 300 Gy per nodule strategy (28±16%; p s can be used independently of the scintigraphic pattern of functional autonomous tissue in the thyroid. (orig.)

  3. EVALUATION OF THYROID HORMONES AND AS INFLUENCED BY TREATMENT WITH DESLORELIN IN PALLAS' CATS (OTOCOLOBUS (FELIS) MANUL).

    Science.gov (United States)

    Delaski, Kristina M; Gamble, Kathryn C

    2015-12-01

    Thyroid hormones regulate a variety of physiologic functions including metabolism, growth, and reproductive cycling, and these other hormones can impact the thyroid function via the hypothalamic-pituitary axis. For instance, the gonadotropin-releasing hormone agonist, deslorelin, used in nondomestic carnivores for contraception and behavioral control, down-regulates reproductive hormones through this mechanism and so may impact thyroid function. Due to clinical concerns of hypothyroidism in a bachelor group of adult male Pallas' cats (Otocolobus (Felis) manul) which also had deslorelin implants, serum samples from treated captive (n = 8) individuals, untreated captive (n = 25), and free-ranging (n = 9) individuals were analyzed for thyroid hormone concentrations. Total and free thyroxine (TT4 and FT4), total and free tri-iodothyronine (TT3 and FT3), and thyroid stimulating hormone (TSH) were measured although, due to sample volume limitations, not every hormone could be analyzed for every sample. Of these hormones, only FT4 was found statistically different between the deslorelin-treated and untreated groups. As samples were unevenly distributed across season, true comparison between seasons could not be made. The values reported for the untreated captive and free-ranging group, while representing a small sample size, can serve as a baseline assessment when evaluating the thyroid status of captive Pallas' cats.

  4. Numerical simulation of homogenization time measurement by probes with different volume size

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostek, M.; Jahoda, M.

    2004-01-01

    Results of continuous homogenization time measurement of liquid in a stirred tank depend on the scale of scrutiny. Experimental techniques use a probe, which is situated inside as a conductivity method, or outside of the tank as in the case of gamma-radiotracer methods. Expected value of homogenization time evaluated for a given degree of homogenization is higher when using the conductivity method because the conductivity probe measures relatively small volume in contrast to application of radiotracer, when the volume is much greater. Measurement through the wall of tank is a great advantage of radiotracer application but a comparison of the results with another method supposes a determination of measured volume, which is not easy. Simulation of measurement by CFD code can help to solve the problem. Methodology for CFD simulation of radiotracer experiments was suggested. Commercial software was used for simulation of liquid homogenization in mixed vessel with Rushton turbine. Numerical simulation of liquid homogenization time by CFD for different values of detected volume was confronted with measurement of homogenization time with conductivity probe and with different radioisotopes 198 Au, 82 Br and 24 Na. Detected size of the tank volume was affected by different energy of radioisotope used. (author)

  5. 3D photography is a reliable method of measuring infantile haemangioma volume over time.

    Science.gov (United States)

    Robertson, Sarah A; Kimble, Roy M; Storey, Kristen J; Gee Kee, Emma L; Stockton, Kellie A

    2016-09-01

    Infantile haemangiomas are common lesions of infancy. With the development of novel treatments utilised to accelerate their regression, there is a need for a method of assessing these lesions over time. Volume is an ideal assessment method because of its quantifiable nature. This study investigated whether 3D photography is a valid tool for measuring the volume of infantile haemangiomas over time. Thirteen children with infantile haemangiomas presenting to the Vascular Anomalies Clinic, Royal Children's Hospital/Lady Cilento Children's Hospital treated with propranolol were included in the study. Lesion volume was assessed using 3D photography at presentation, one month and three months follow up. Intrarater reliability was determined by retracing all images several months after the initial mapping. Interrater reliability of the 3D camera software was determined by two investigators, blinded to each other's results, independently assessing infantile haemangioma volume. Lesion volume decreased significantly between presentation and three-month follow-up (p<0.001). Volume intra- and interrater reliability were excellent with ICC 0.991 (95% CI 0.982, 0.995) and 0.978 (95% CI 0.955, 0.989), respectively. This study demonstrates images taken with the 3D LifeViz™ camera and lesion volume calculated with Dermapix® software is a reliable method for assessing infantile haemangioma volume over time. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Significance of left ventricular volume measurement after heart transplantation using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.; Boniaszczuk, J.

    1985-01-01

    Multigated equilibrium blood pool scanning using Technetium 99m labeled red blood cells was used to measure left ventricular volumes in three heterotopic and one orthotopic heart transplant recipient(s). Simultaneously, an endomyocardial biopsy was performed and the degree of acute rejection was assessed by a histological scoring system. The scores were correlated to changes in ejection fraction and heart rate. Technetium 99m scanning data were pooled according to the endomyocardial biopsy score: no rejection; mild rejection; moderate rejection, and severe rejection. In each group, the median of the left ventricular volume parameters was calculated and correlated with the endomyocardial biopsy score, using a non-parametric one-way analysis of variance. A decrease in stroke volume correlated best with the endomyocardial biopsy score during acute rejection. A decrease in end-diastolic left ventricular volumes did not correlate as well. Changes in the end-systolic left ventricular volumes were not statistically significant, but using a simple correlation between end-systolic left ventricular volumes and endomyocardial biopsy the correlation reached significance. Changes in left ventricular volumes measured by Technetium 99m scanning may be useful to confirm the presence or absence of acute rejection in patients with heart grafts

  7. Maternal Thyroid Dysfunction and Neonatal Thyroid Problems

    Science.gov (United States)

    Ozdemir, Hulya; Akman, Ipek; Coskun, Senay; Demirel, Utku; Turan, Serap; Bereket, Abdullah; Bilgen, Hulya; Ozek, Eren

    2013-01-01

    Aim. To investigate obstetric features of pregnant women with thyroid disorders and thyroid function tests of their newborn infants. Methods. Women with hypothyroidism and having anti-thyroglobulin (ATG) and anti-thyroid peroxidase (anti-TPO) antibodies were assigned as group I, women with hypothyroidism who did not have autoantibodies were assigned as group II, and women without thyroid problems were assigned as group III. Results. Pregnant women with autoimmune hypothyroidism (group I) had more preterm delivery and their babies needed more frequent neonatal intensive care unit (NICU) admission. In group I, one infant was diagnosed with compensated hypothyroidism and one infant had transient hyperthyrotropinemia. Five infants (23.8%) in group II had thyroid-stimulating hormone (TSH) levels >20 mIU/mL. Only two of them had TSH level >7 mIU/L at the 3rd postnatal week, and all had normal free T4 (FT4). Median maternal TSH level of these five infants with TSH >20 mIU/mL was 6.6 mIU/mL. In group III, six infants (6.5%) had TSH levels above >20 mIU/mL at the 1st postnatal week. Conclusion. Infants of mothers with thyroid problems are more likely to have elevated TSH and higher recall rate on neonatal thyroid screening. Women with thyroid disorders and their newborn infants should be followed closely for both obstetrical problems and for thyroid dysfunction. PMID:23737782

  8. Maternal Thyroid Dysfunction and Neonatal Thyroid Problems

    Directory of Open Access Journals (Sweden)

    Hulya Ozdemir

    2013-01-01

    Full Text Available Aim. To investigate obstetric features of pregnant women with thyroid disorders and thyroid function tests of their newborn infants. Methods. Women with hypothyroidism and having anti-thyroglobulin (ATG and anti-thyroid peroxidase (anti-TPO antibodies were assigned as group I, women with hypothyroidism who did not have autoantibodies were assigned as group II, and women without thyroid problems were assigned as group III. Results. Pregnant women with autoimmune hypothyroidism (group I had more preterm delivery and their babies needed more frequent neonatal intensive care unit (NICU admission. In group I, one infant was diagnosed with compensated hypothyroidism and one infant had transient hyperthyrotropinemia. Five infants (23.8% in group II had thyroid-stimulating hormone (TSH levels >20 mIU/mL. Only two of them had TSH level >7 mIU/L at the 3rd postnatal week, and all had normal free T4 (FT4. Median maternal TSH level of these five infants with TSH >20 mIU/mL was 6.6 mIU/mL. In group III, six infants (6.5% had TSH levels above >20 mIU/mL at the 1st postnatal week. Conclusion. Infants of mothers with thyroid problems are more likely to have elevated TSH and higher recall rate on neonatal thyroid screening. Women with thyroid disorders and their newborn infants should be followed closely for both obstetrical problems and for thyroid dysfunction.

  9. Effect of Breath Holding on Spleen Volume Measured by Magnetic Resonance Imaging.

    Science.gov (United States)

    Inoue, Yusuke; Nakajima, Ai; Mizukami, Shinya; Hata, Hirofumi

    2013-01-01

    Ultrasonographic studies have demonstrated transient reduction in spleen volume in relation to apnea diving. We measured spleen volume under various respiratory conditions by MR imaging to accurately determine the influence of ordinary breath holding on spleen volumetry. Twelve healthy adult volunteers were examined. Contiguous MR images of the spleen were acquired during free breathing and during respiratory manipulations, including breath holding at the end of normal expiration, breath holding at deep inspiration, and the valsalva maneuver, and spleen volume was measured from each image set based on the sum-of-areas method. Acquisition during free breathing was performed with respiratory triggering. The duration of each respiratory manipulation was 30 s, and five sets of MR images were acquired serially during each manipulation. Baseline spleen volume before respiratory manipulation was 173.0 ± 79.7 mL, and the coefficient of variance for two baseline measures was 1.4% ± 1.6%, suggesting excellent repeatability. Spleen volume decreased significantly just after the commencement of respiratory manipulation, remained constant during the manipulation, and returned to the control value 2 min after the cessation of the manipulation, irrespective of manipulation type. The percentages of volume reduction were 10.2% ± 2.9%, 10.2% ± 3.5%, and 13.3% ± 5.7% during expiration breath holding, deep-inspiration breath holding, and the valsalva maneuver, respectively, and these values did not differ significantly. Spleen volume is reduced during short breath-hold apnea in healthy adults. Physiological responses of the spleen to respiratory manipulations should be considered in the measurement and interpretation of spleen volume.

  10. Self-weight effect in the measurement of the volume of silicon spheres

    Science.gov (United States)

    Mari, D.; Massa, E.; Kuramoto, N.; Mana, G.

    2018-04-01

    The volume of 28Si spheres about 94 mm in diameter is an input datum for the determination of the Avogadro constant. We report a finite element analysis of the self-weight effect on the volume determination via optical interferometric measurements of the sphere diameters. The self-weight expansion or shrinkage of the equatorial diameters, which ranges from  -31 pm to  +180 pm, depends on the southern latitude of the supports.

  11. Radioiodine treatment for malignant thyroid disease

    International Nuclear Information System (INIS)

    Berg, Gertrud

    2006-01-01

    Radioiodine treatment for thyroid disease has been given for half a decade in Sweden. The most common indication for treatment is hyperthyroidism, when iodine uptake is high. The situation in which radioiodine treatment is used in thyroid cancer is less favourable and measures therefore have to be taken to optimize the treatment. Treatment should be performed early in the course of the disease to achieve the highest possible differentiation. Before treatment the iodine and goitrogen intake should be kept low. Stimulation of the thyrocytes by thyroid-stimulating hormone (TSH) should be high. It is conventionally achieved by thyroid hormone withdrawal rendering the patient hypothyroid, or by the recently available recombinant human TSH (rhTSH) which can be recommended for ablation of the thyroid remnant after thyroidectomy and for treatment of metastases in fragile patients unable to undergo hypothyroidism. Finally, stunning - the negative effect of a prior test dose from radioactive iodine - should be avoided

  12. The Effect of a Finite Measurement Volume on Power Spectra from a Burst Type LDA

    DEFF Research Database (Denmark)

    Buchhave, Preben; Velte, Clara Marika; K. George, William

    2014-01-01

    We analyze the effects of a finite size measurement volume on the power spectrum computed fromdata acquired with a burst-type laser Doppler anemometer. The finite measurement volume causes temporal distortions in acquisition of the data resulting in phenomena such as finite processing time and dead...... time.We compare analytical expressions for the bias and distortion of the velocity power spectrum computed from computer-generated data. We then compare the spectrum from the computer-generated data and a power spectrum from a measurement on a free turbulent jet in air and conclude that we have a valid...

  13. {sup 131}I-induced changes in rat thyroid gland function

    Energy Technology Data Exchange (ETDEWEB)

    Torlak, V.; Capkun, V.; Stanicic, A. [Clinical Hospital Split, Split (Croatia). Dept. of Nuclear Medicine; Zemunik, T. [University of Split, Split (Croatia). Dept. of Medical Biology]. E-mail: tzemunik@bsb.mefst.hr; Modun, D. [University of Split, Split (Croatia). Dept. of Pharmacology; Pesutic-Pisac, V. [Clinical Hospital Split, Split (Croatia). Dept. of Pathology; Markotic, A. [University of Split, Split (Croatia). School of Medicine. Dept. of Biochemistry; Pavela-Vrancic, M. [University of Split, Split (Croatia). Faculty of Natural Sciences. Dept. of Chemistry

    2007-08-15

    Therapeutic doses of {sup 131}I administered to thyrotoxic patients may cause thyroid failure. The present study used a rat model to determine thyroid function after the administration of different doses of {sup 131}I (64-277 {mu}Ci). Thirty male Fisher rats in the experimental group and 30 in the control group (untreated) were followed for 6 months. The animals were 4 months old at the beginning of the experiment and were sacrificed at an age of 9 months. Hormone concentration was determined before {sup 131}I administration (4-month-old animals) and three times following {sup 131}I administration, when the animals were 7, 8, and 9 months old. The thyroid glands were removed and weighed, their volume was determined and histopathological examination was performed at the end of the experiment. Significant differences in serum triiodothyronine and thyroid-stimulating hormone concentration, measured at the age of 7, 8, and 9 months, were found in the experimental group. During aging of the animals, the concentration of thyroxin fell from 64.8 {+-} 8.16 to 55.0 {+-} 6.1 nM in the control group and from 69.4 {+-} 6.9 to 25.4 {+-} 3.2 nM in the experimental group. Thyroid gland volume and weight were significantly lower in the experimental than in the control group. Thyroid glands from the experimental group showed hyaline thickness of the blood vessel wall, necrotic follicles, a strong inflammatory reaction, and peeling of necrotic cells in the follicles. In conclusion, significant differences in hormone levels and histopathological findings indicated prolonged hypothyroidism after {sup 131}I administration to rats, which was not {sup 131}I dose dependent. (author)

  14. Thyroid function in Danish greenhouse workers

    Directory of Open Access Journals (Sweden)

    Bonde Jens

    2006-12-01

    Full Text Available Abstract Background From animal studies it is known that currently used pesticides can disturb thyroid function. Methods In the present study we investigated the thyroid function in 122 Danish greenhouse workers, to evaluate if greenhouse workers classified as highly exposed to pesticides experiences altered thyroid levels compared to greenhouse workers with lower exposure. Serum samples from the greenhouse workers were sampled both in the spring and the fall to evaluate if differences in pesticide use between seasons resulted in altered thyroid hormone levels. Results We found a moderate reduction of free thyroxine (FT4 (10–16% among the persons working in greenhouses with a high spraying load both in samples collected in the spring and the fall, but none of the other measured thyroid hormones differed significantly between exposure groups in the cross-sectional comparisons. However, in longitudinal analysis of the individual thyroid hormone level between the spring and the fall, more pronounced differences where found with on average 32% higher thyroid stimulating hormone (TSH level in the spring compared to the fall and at the same time a 5–9% lower total triiodthyroxin (TT3, free triiodthyroxine (FT3 and FT4. The difference between seasons was not consistently more pronounced in the group classified as high exposure compared to the low exposure groups. Conclusion The present study indicates that pesticide exposure among Danish greenhouse workers results in only minor disturbances of thyroid hormone levels.

  15. Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

    DEFF Research Database (Denmark)

    Sandholt, Benjamin V; Collet-Billon, Antoine; Entrekin, Robert

    2018-01-01

    (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient...

  16. Measuring air layer volumes retained by submerged floating-ferns Salvinia and biomimetic superhydrophobic surfaces

    Directory of Open Access Journals (Sweden)

    Matthias J. Mayser

    2014-06-01

    Full Text Available Some plants and animals feature superhydrophobic surfaces capable of retaining a layer of air when submerged under water. Long-term air retaining surfaces (Salvinia-effect are of high interest for biomimetic applications like drag reduction in ship coatings of up to 30%. Here we present a novel method for measuring air volumes and air loss under water. We recorded the buoyancy force of the air layer on leaf surfaces of four different Salvinia species and on one biomimetic surface using a highly sensitive custom made strain gauge force transducer setup. The volume of air held by a surface was quantified by comparing the buoyancy force of the specimen with and then without an air layer. Air volumes retained by the Salvinia-surfaces ranged between 0.15 and 1 L/m2 depending on differences in surface architecture. We verified the precision of the method by comparing the measured air volumes with theoretical volume calculations and could find a good agreement between both values. In this context we present techniques to calculate air volumes on surfaces with complex microstructures. The introduced method also allows to measure decrease or increase of air layers with high accuracy in real-time to understand dynamic processes.

  17. Validity and repeatability of a depth camera-based surface imaging system for thigh volume measurement.

    Science.gov (United States)

    Bullas, Alice M; Choppin, Simon; Heller, Ben; Wheat, Jon

    2016-10-01

    Complex anthropometrics such as area and volume, can identify changes in body size and shape that are not detectable with traditional anthropometrics of lengths, breadths, skinfolds and girths. However, taking these complex with manual techniques (tape measurement and water displacement) is often unsuitable. Three-dimensional (3D) surface imaging systems are quick and accurate alternatives to manual techniques but their use is restricted by cost, complexity and limited access. We have developed a novel low-cost, accessible and portable 3D surface imaging system based on consumer depth cameras. The aim of this study was to determine the validity and repeatability of the system in the measurement of thigh volume. The thigh volumes of 36 participants were measured with the depth camera system and a high precision commercially available 3D surface imaging system (3dMD). The depth camera system used within this study is highly repeatable (technical error of measurement (TEM) of <1.0% intra-calibration and ~2.0% inter-calibration) but systematically overestimates (~6%) thigh volume when compared to the 3dMD system. This suggests poor agreement yet a close relationship, which once corrected can yield a usable thigh volume measurement.

  18. Medullary carcinoma of the thyroid

    International Nuclear Information System (INIS)

    Samuel, A.M.; Pradhan, S.A.; D'Cruz, A.; Shah, D.H.

    1999-01-01

    Medullary thyroid carcinoma is a biologically distinct form of thyroid cancer and accounts for 5-10% of all thyroid neoplasms. Twenty percent of MTC can occur in a familial setting either by itself or as part of the multiple endocrine neoplasm syndromes. A disciplined approach is necessary in the work-up of these patients to rule out coexistent endocrine tumors (pheochromocytomas and parathyroid). Cacitonin is a sensitive tumor marker secreted by MTC that is of prognostic value and important in the follow-up of patients. Surgery is the mainstay of treatment with a total thyroidectomy and centre compartment clearance being the minimum for patients without cervical adenopathy. Radiotherapy has a limited role and is only indicated as a palliative measure in patients with advanced/metastatic disease not amenable to surgery

  19. [Iodine excess induced thyroid dysfunction].

    Science.gov (United States)

    Egloff, Michael; Philippe, Jacques

    2016-04-20

    The principle sources of iodine overload, amiodarone and radiologic contrast media, are frequently used in modern medicine. The thyroid gland exerts a protective effect against iodine excess by suppressing iodine internalization into the thyrocyte and iodine organification, the Wolff-Chaikoff effect. Insufficiency of this effect or lack of escape from it leads to hypo- or hyperthyroidism respectively. Amiodarone induced thyrotoxicosis is a complex condition marked by two different pathophysiological mechanisms with different treatments. Thyroid metabolism changes after exposure to radiologic contrast media are frequent, but they rarely need to be treated. High risk individuals need to be identifed in order to delay the exam or to monitor thyroid function or apply prophylactic measures in selected cases.

  20. Assessment of ovarian reserve in euthyroid adolescents with Hashimoto thyroiditis.

    Science.gov (United States)

    Pirgon, Ozgur; Sivrice, Cigdem; Demirtas, Hakan; Dundar, Bumin

    2016-01-01

    We aimed to investigate the ovarian function and reserve in euthyroid adolescents (TSH Hashimoto thyroiditis (HT). This case-control study included 30 adolescent girls (mean age 15.1 ± 1.4 years) newly diagnosed as HT with presence of high thyroid antibodies with gland heterogeneity in ultrasound and age-matched 30 healthy female subjects. Anti-ovarian antibody (AOAb), LH/FSH ratio, estradiol, anti-mullerian hormone (AMH), inhibin-B, total testosterone, antral follicle count, ovarian volumes and uterine length were measured. The clinical, laboratory, and ultrasound data of the HT and control groups were compared. There were no significant differences between the girls with HT and healthy controls in relation to LH/FSH ratio, estradiol and inhibin-B levels. AOAb (p = 0.02), AMH (p = 0.007) and total testosterone levels were higher in HT group than the control group (p = 0.03). AOAb level was found to be positively correlated with LH/FSH ratio (p = 0.03), AMH (p = 0.01) and inhibin-B (p < 0.001) in HT group. This study demonstrated that the adolescent girls diagnosed with autoimmune thyroiditis had normal ovarian reserve based on measurements of AMH, inhibin B, FSH, LH/FSH ratio, estradiol and antral follicle counts.

  1. Thyroid Hormone Treatment

    Science.gov (United States)

    ... THYROID HORMONES? Desiccated ( dried and powdered ) animal thyroid ( Armour ®), now mainly obtained from pigs, was the most ... Information A LISTING OF THE FDA-APPROVED MEDICINES PRODUCT FDA RATING MANUFACTURER Unithroid® AB (Stevens)*+ L-Thyroxin ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... which are encased in metal and plastic and most often shaped like a box, attached to a ... will I experience during and after the procedure? Most thyroid scan and thyroid uptake procedures are painless. ...

  3. Retrosternal thyroid surgery

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007558.htm Retrosternal thyroid surgery To use the sharing features on this page, please enable JavaScript. The thyroid gland is normally located at the front of ...

  4. Thyroid preparation overdose

    Science.gov (United States)

    Thyroid preparations are medicines used to treat thyroid gland disorders. Overdose occurs when someone takes more than the normal or recommended amount of this medicine. This can be by accident or ...

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Most thyroid scan and thyroid uptake ... you otherwise, you may resume your normal activities after your nuclear medicine scan. If any special instructions ...

  6. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Because nuclear medicine procedures are able to pinpoint molecular activity within the body, they offer the potential ... or imaging device that produces pictures and provides molecular information. The thyroid scan and thyroid uptake provide ...

  7. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... thyroid. The thyroid is a gland in the neck that controls metabolism , a chemical process that regulates ... examination table with your head tipped backward and neck extended. The gamma camera will then take a ...

  8. Cabozantinib (thyroid cancer)

    Science.gov (United States)

    ... is used to treat a certain type of thyroid cancer that is getting worse and that has spread ... only gives information about cabozantinib capsules (Cometriq) for thyroid cancer. If you are using this medication for advanced ...

  9. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Uptake? A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) ... of thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that ...

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) is ... thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that uses ...

  11. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Uptake? A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) is ... of thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that uses ...

  12. Comparison of bone volume measurements using conventional single and dual energy computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yung Kyoon; Park, Sang Hoon [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Yon Min [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2017-06-15

    The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection( keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting( MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed 35.8±12.2 for rib, femur (16.1±24.1), pelvis(13.7±18.8), and spine(179.0±61.8). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

  13. Shear-Wave Elastography for the Preoperative Risk Stratification of Follicular-patterned Lesions of the Thyroid: Diagnostic Accuracy and Optimal Measurement Plane.

    Science.gov (United States)

    Samir, Anthony E; Dhyani, Manish; Anvari, Arash; Prescott, Jason; Halpern, Elkan F; Faquin, William C; Stephen, Antonia

    2015-11-01

    To evaluate the diagnostic accuracy of shear-wave elastography (SWE) for the diagnosis of malignancy in follicular lesions and to identify the optimal SWE measurement plane. The institutional review board approved this HIPAA-compliant, single-institution, prospective pilot study. Subjects scheduled for surgery after a previous fine-needle aspiration report of "atypia of undetermined significance" or "follicular lesion of undetermined significance," "suspicion for follicular neoplasm," or "suspicion for Hurthle cell neoplasm," were enrolled after obtaining informed consent. Subjects underwent conventional ultrasonography (US), Doppler evaluation, and SWE preoperatively, and their predictive value for thyroid malignancy was evaluated relative to the reference standard of surgical pathologic findings. Thirty-five patients (12 men, 23 women) with a mean age of 55 years (range, 23-85 years) and a fine-needle aspiration diagnosis of atypia of undetermined significance or follicular lesion of undetermined significance (n = 16), suspicion for follicular neoplasm (n = 14), and suspicion for Hurthle cell neoplasm (n = 5) were enrolled in the study. Male sex was a statistically significant (P = .02) predictor of malignancy, but age was not. No sonographic morphologic parameter, including nodule size, microcalcification, macrocalcification, halo sign, taller than wide dimension, or hypoechogenicity, was associated with malignancy. Similarly, no Doppler feature, including intranodular vascularity, pulsatility index, resistive index, or peak-systolic velocity, was associated with malignancy. Higher median SWE tissue Young modulus estimates from the transverse insonation plane were associated with malignancy, yielding an area under the receiver operating characteristic curve of 0.81 (95% confidence interval: 0.62, 1.00) for differentiation of malignant from benign nodules. At a cutoff value of 22.3 kPa, sensitivity, specificity, positive predictive value, and negative predictive

  14. Macular thickness and macular volume measurements using spectral domain optical coherence tomography in normal Nepalese eyes

    Directory of Open Access Journals (Sweden)

    Pokharel A

    2016-03-01

    Full Text Available Amrit Pokharel,1 Gauri Shankar Shrestha,2 Jyoti Baba Shrestha2 1Department of Ophthalmology, Kathmandu Medical College Teaching Hospital, 2B P Koirala Lions Centre for Ophthalmic Studies, Institute of Medicine, Kathmandu, Nepal Purpose: To record the normative values for macular thickness and macular volume in normal Nepalese eyes. Methods: In all, 126 eyes of 63 emmetropic subjects (mean age: 21.17±6.76 years; range: 10–37 years were assessed for macular thickness and macular volume, using spectral domain-optical coherence tomography over 6×6 mm2 in the posterior pole. A fast macular thickness protocol was employed. Statistics such as the mean, median, standard deviation, percentiles, and range were used, while a P-value was set at 0.05 to test significance. Results: Average macular thickness and total macular volume were larger in males compared to females. With each year of increasing age, these variables decreased by 0.556 µm and 0.0156 mm3 for average macular thickness and total macular volume, respectively. The macular thickness was greatest in the inner superior section and lowest at the center of the fovea. The volume was greatest in the outer nasal section and thinnest in the fovea. The central subfield thickness (r=-0.243, P=0.055 and foveal volume (r=0.216, P=0.09 did not correlate with age. Conclusion: Males and females differ significantly with regard to macular thickness and macular volume measurements. Reports by other studies that the increase in axial length reduced thickness and volume, were negated by this study which found a positive correlation among axial length, thickness, and volume. Keywords: macular thickness, macular volume, optical coherence tomography, Nepal

  15. 35Cl- and 2H NMR measurement of intracellular water volume in renal proximal tubules

    International Nuclear Information System (INIS)

    Hoffman, D.; Kumar, A.M.; Spitzer, A.; Gupta, R.K.

    1986-01-01

    Knowledge of cell water volume is essential for the calculation of concentrations of intracellular ions and metabolites in kidney tubules. The authors have developed a method which utilizes 35 Cl - NMR as a measure of extracellular volume and 2 H NMR in combination with a membrane-impermeant shift reagent Dy(DTPA) as a measure of the ratio of intra- and extracellular water volumes. Measurement of extracellular volume by 35 Cl - NMR is possible since intracellular 35 Cl - resonance is broadened beyond detection in most cells. The 2 H NMR measurements exploit the fact that only extracellular water is in direct contact with Dy(DTPA). However, rapid exchange of water across the cell membrane results in only a single 2 H 2 O resonance at a chemical shift which is a weighted average of the shifted extra- and unshifted intracellular water resonances. Denoting the extracellular volume as a fraction of the total volume by S/sub o/, and as a fraction of the total water volume by H/sub o/, the fractional cell water content, W = [(1/H/sub o/) -1]/[(1/S/sub o/)-1], can be calculated. Rat proximal tubule suspensions were prepared by the method developed in their laboratory. The water content was found to be 76.9 +/- 5% (anti +/- x SD, n = 4) at room temperature and 78.6% at 37 0 C. Increasing extracellular osmolality from 295 to 330 mosm/kg, by addition of mannitol, decreased the water content to 70.8%. The authors results are in good agreement with the previously reported values of 69-82%, obtained by other methods. Thus, NMR is an accurate, noninvasive method for measuring the water content of renal cells

  16. Optimization of the therapeutic dose of 131I for thyroid differentiated carcinoma

    International Nuclear Information System (INIS)

    Lima, Fabiana Farias de

    2002-09-01

    I-131 thyroid cancer therapy is based on the strategy of concentrating radioactive iodine in the thyroid tissue, to completetly eliminate thyroid tissue and functioning thyroid cancer metastases remaining after thyroidectomy. In Brazil, fixed activities of 131 I generally are given, sometimes either delivering insufficient activities to ablate all of the remnants, or unnecessarily high activities, with patients remaining in the hospital for some period of time. This investigation proposes a protocol of individualized planning of ablative doses, based on individual patients metabolisms and measured thyroid remnant masses. Simulated thyroid remnants were fabricated in various forms, volumes and activities, and optimum image acquisition parameters were determined using Single-Photon Emission Computed Tomography 9SPECT). Resultant images were evaluated, to determine the apparent volumes and the 131 I concentrations. I-131 metabolism was studied in 9 patients who had undergone thyroidectomies. Their thyroid remnant masses were determined applying the same parameters used in SPECT simulation studies, and the optimum activity for their therapy was calculated and compared to the established fixed activity of 3.7 GBq (100 mCi), which would have normally been assigned. Background subtraction using the method of percent maximum counts, using a value of 67.5%, combined with scatter correction (triple energy window method), was shown to be optimum for SPECT quantification of volumes between 3-10 ml. Errors in the method were below 9% for sources with regular geometries and around 11% for sources with irregular geometries. In the patient studies, it was observed that 78% of patients could have received reduced activities of 131 (from 0.8-3-2. GBq (20-87 nCi). In addition, 33% of these patients could have received low enough activities to have discharged from the hospital, using an individualized administration scheme. This could also have resulted in a dose reduction for many

  17. Measurement for serum thyroxine-binding globulin (TBG) and its clinical assessment in diagnosis of thyroid states

    International Nuclear Information System (INIS)

    Imamura, Rikiyo; Yoshimasa, Yasunao; Hamada, Satoshi

    1979-01-01

    Serum levels of thyroxine (T 4 )-binding globulin (TBG) were determined by a radioimmunoassay using cellulose-linked antibody to TBG. Values obtained in healthy young adults averaged 1.62 +- 0.25 (SD) mg/100 ml, and no significant difference was detected between males and females. The TBG levels remained within the normal limit in hyperthyroidism while they were significantly increased in hypothyroidism. Interestingly enough, TBG levels were significantly elevated in chronic thyroidities with no overt hypothyroidism. In normal pregnancy, TBG was increased slightly in the first trimester, and markedly in the second and third trimesters. In one case of congenital TBG deficiency, no immunoreactive TBG was detected. It was demonstrated, further, that an inverse relationship (r = -0.7593) existed between the TBG level and serum triiodothyronine uptake index, and that a direct relation (r = +0.6557) was present between the TBG level and T 4 in sera from normal subjects and pregnancy. Ratios of T 4 /TBG were markedly increased in hyperthyroidism, and decreased in hypothyroidism, showing no overlap with the normal subjects, whereas they were below the normal limit in half the cases in the second and third trimesters of pregnancy. The radioimmunoassay for TBG was useful in evaluating hypothyroid states, because it could differentiate the increase in T 4 associated with elevated TBG from hyperthyroidism. (author)

  18. Analysis of the bethesda system for reporting thyroid cytopathology and similar precursor thyroid cytopathology reporting schemes.

    Science.gov (United States)

    Wong, Lawrence Q; Baloch, Zubair W

    2012-09-01

    The Bethesda System for Reporting Thyroid Cytopathology is a standardized reporting system for classifying thyroid fine-needle aspiration results comprising of 6 diagnostic categories with unique risks of malignancy and recommendations for clinical management. The majority of thyroid nodules are benign; however, up to 30% of fine-needle aspiration of thyroid nodule results are equivocal. Until 2007, various diagnostic terms were used to classify such cases, including "atypical," "indeterminate," and rule-out or cannot exclude malignancy. A literature review of 13 original studies was conducted to evaluate whether utilization of the Bethesda System for Reporting Thyroid Cytopathology nomenclature represent an improvement over thyroid cytopathology reporting schemes used before 2007 in diagnosing thyroid malignancy. The sensitivity and specificity of thyroid fine-needle aspiration was high in the studies that assessed the measures. However, a selection bias exists and most studies do not include indeterminate diagnosis in their calculations. Although the Bethesda System for Reporting Thyroid Cytopathology recommends a repeat fine-needle aspiration to follow-up nondiagnostic specimens, in the majority of studies, an appreciable number of cases underwent follow-up surgical biopsy or thyroidectomy. The diagnostic category of atypia/follicular lesion of undetermined significance remains heterogenous in terms of usage and clinical outcome. The majority of the studies that utilize the Bethesda System for Reporting Thyroid Cytopathology in this literature review retrospectively reclassified thyroid fine-needle aspiration into the Bethesda System for Reporting Thyroid Cytopathology nomenclature with reported malignancy rates that are similar between cases reclassified as atypia/follicular lesion of undetermined significance and follicular neoplasm/suspicious for follicular neoplasm.

  19. Clinical significance of endogenously labelled thyroid hormones in the diagnosis of thyroidal autonomy

    International Nuclear Information System (INIS)

    Waters, W.; Kutzim, H.

    1983-01-01

    The clinical value of the determination of 123 I concentration in serum 48 hrs after tracer administration ( 123 I) 48 is investigated with special regard to thyroidal autonomy. Serum radioiodine concentration, thyroid radioiodide uptake at 4 and at 48 hrs were measured in 74 healthy subjects and patients with simple goiter, in 36 patients with thyroidal autonomy (diagnosis by thyroid suppression test), and in 20 hyperthyroid patients. 83% of the patients with elevated radioiodine concentration belonged to the group of thyroidal autonomy. The product of radioiodine concentration and thyroid radioiodide uptake is a much better parameter. 95% of the patients in which this product was elevated, belonged to the autonomy group (5% diagnostic error). Also in the control group the diagnostic error was 5%. The combination of ( 123 I) 48 with the result of the TRH-test is very useful in excluding thyroidal autonomy, if ( 123 I) 48 is normal and the TRH-test is positive (100% of the patients have regulated thyroid glands.) 94% of the patients having elevated ( 123 I) 48 and a negative TRH-test belonged to the group of thyroidal autonomy. A very useful combination for the diagnosis of borderline hyperthyroidism is the determination of the product of ( 123 I) 48 and the uptake together with the pulse rate or fine tremor of the fingers (or TRH-test). The results suggest that the determination of ( 123 I) 48 is a very good parameter of thyroidal autonomy beside the thyroid suppression test. It may be used alone for the diagnosis of thyroidal autonomy if the suppression test is contraindicated. In the diagnosis of borderline hyperthyroidism its determination makes the suppression test unnecessary in many instances. (orig.) [de

  20. Carcinoembryonic antigen in thyroid cancer

    International Nuclear Information System (INIS)

    Weissel, M.; Hoefer, R.

    1982-01-01

    In order to investigate the usefulness of determining the serum concentrations of carcinoembryonic antigen (CEA) as a specific tumor marker in thyroid cancer, CEA serum levels were measured (enzymeimmunoassay, Abbott-Kit) repeatedly at the routine followup checks performed at various intervals after total thyroidectomy, in 65 patients with papillary, 82 with follicular, 25 with mixed type (papillary/follicular), 8 with anaplastic, and in 18 patients with medullary thyroid cancer. The postoperative observation period of these patients ranged from 2 to 36 months. Calcitonin serum levels were additionally determined in patients with medullary carcinoma (radioimmunoassay kit of Immuno-Nuclear Corp.). In the family of one patient with medullary carcinoma we also had an opportunity to investigate, within the framework of family screening (pentagastrin tests, etc.), the value of preoperative CEA determination. In the patients with ''non-medullary'' histological types of thyroid cancer, the maximum CEA serum concentration was 9.8 ng/ml. 6% of the patients with papillary, 9% of the patients with follicular, and 8% of those with mixed type thyroid cancer had serum levels above the upper limit of our normal range (5 ng/ml). All patients with anaplastic carcinoma had values below 3 ng/ml. The values quoted represent maximal values and were confirmed at various follow-up checks. However, 1 year after thyroidectomy, a female patient with follicular thyroid carcinoma developed an adenocarcinoma of the rectum: The CEA levels measured in this patient were: 4.2 ng/ml 3 weeks after thyroidectomy, 8.4 ng/ml 6 months later, and 37 ng/ml 1 week before operation on the rectum. In none of the other patients with elevated CEA levels were metastases of thyroid cancer, or any other malignancy, detected. (orig.) [de

  1. MRI markers for mild cognitive impairment: comparisons between white matter integrity and gray matter volume measurements.

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    Full Text Available The aim of the study was to evaluate the value of assessing white matter integrity using diffusion tensor imaging (DTI for classification of mild cognitive impairment (MCI and prediction of cognitive impairments in comparison to brain atrophy measurements using structural MRI. Fifty-one patients with MCI and 66 cognitive normal controls (CN underwent DTI and T1-weighted structural MRI. DTI measures included fractional anisotropy (FA and radial diffusivity (DR from 20 predetermined regions-of-interest (ROIs in the commissural, limbic and association tracts, which are thought to be involved in Alzheimer's disease; measures of regional gray matter (GM volume included 21 ROIs in medial temporal lobe, parietal cortex, and subcortical regions. Significant group differences between MCI and CN were detected by each MRI modality: In particular, reduced FA was found in splenium, left isthmus cingulum and fornix; increased DR was found in splenium, left isthmus cingulum and bilateral uncinate fasciculi; reduced GM volume was found in bilateral hippocampi, left entorhinal cortex, right amygdala and bilateral thalamus; and thinner cortex was found in the left entorhinal cortex. Group classifications based on FA or DR was significant and better than classifications based on GM volume. Using either DR or FA together with GM volume improved classification accuracy. Furthermore, all three measures, FA, DR and GM volume were similarly accurate in predicting cognitive performance in MCI patients. Taken together, the results imply that DTI measures are as accurate as measures of GM volume in detecting brain alterations that are associated with cognitive impairment. Furthermore, a combination of DTI and structural MRI measurements improves classification accuracy.

  2. Automated cross-sectional and longitudinal hippocampal volume measurement in mild cognitive impairment and Alzheimer's disease.

    Science.gov (United States)

    Leung, Kelvin K; Barnes, Josephine; Ridgway, Gerard R; Bartlett, Jonathan W; Clarkson, Matthew J; Macdonald, Kate; Schuff, Norbert; Fox, Nick C; Ourselin, Sebastien

    2010-07-15

    Volume and change in volume of the hippocampus are both important markers of Alzheimer's disease (AD). Delineation of the structure on MRI is time-consuming and therefore reliable automated methods are required. We describe an improvement (multiple-atlas propagation and segmentation (MAPS)) to our template library-based segmentation technique. The improved technique uses non-linear registration of the best-matched templates from our manually segmented library to generate multiple segmentations and combines them using the simultaneous truth and performance level estimation (STAPLE) algorithm. Change in volume over 12months (MAPS-HBSI) was measured by applying the boundary shift integral using MAPS regions. Methods were developed and validated against manual measures using subsets from Alzheimer's Disease Neuroimaging Initiative (ADNI). The best method was applied to 682 ADNI subjects, at baseline and 12-month follow-up, enabling assessment of volumes and atrophy rates in control, mild cognitive impairment (MCI) and AD groups, and within MCI subgroups classified by subsequent clinical outcome. We compared our measures with those generated by Surgical Navigation Technologies (SNT) available from ADNI. The accuracy of our volumes was one of the highest reported (mean(SD) Jaccard Index 0.80(0.04) (N=30)). Both MAPS baseline volume and MAPS-HBSI atrophy rate distinguished between control, MCI and AD groups. Comparing MCI subgroups (reverters, stable and converters): volumes were lower and rates higher in converters compared with stable and reverter groups (pmethods give accurate and reliable volumes and atrophy rates across the clinical spectrum from healthy aging to AD. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  4. Dimensions et measure de la vitalite linguistique (Dimensions and Measurement of Linguistic Vitality). Volume 1. Publication G-9.

    Science.gov (United States)

    McConnell, Grant D.; Gendron, Jean-Denis

    The first volume of a study of the vitality of written Indian languages explains a computerized system for rating vitality and tests certain demographic variables, with statistical analysis, to determine their influence on the vitality rating. An introductory section examines the concept of linguistic vitality and issues of its measurement. The…

  5. Pulse dye densitometry using indigo carmine is useful for cardiac output measurement, but not for circulating blood volume measurement.

    Science.gov (United States)

    Fujita, Y; Yamamoto, T; Fuse, M; Kobayashi, N; Takeda, S; Aoyagi, T

    2004-08-01

    We evaluated the validity of a newly developed pulse dye densitometer for indigo carmine for measuring cardiac output and circulating blood volume. Measurements of cardiac output and circulating blood volume were performed with the indigo carmine densitometer during normovolaemia, hypovolaemia and hypervolaemia in nine mongrel dogs under general anaesthesia. The validity was evaluated by comparison of the values of cardiac output and circulating blood volume obtained by the thermodilution technique and the 51Cr-labelled red blood cell method, respectively. We also examined indigo carmine removal by continuous veno-venous haemofiltration after indigo carmine injection. There was good agreement between dye densitometer- and thermodilution-derived cardiac output (r = 0.885, P dye-densitometer-derived circulating blood volume was greater than that of the 51Cr-labelled red blood cell method, and both values showed weak agreement (r = 0.587, P indigo carmine through continuous veno-venous haemofiltration was 0.34+/-0.06. These data indicate that indigo carmine densitometry is a reliable method for cardiac output determination, but it overestimates circulating blood volume, probably due to the transition of indigo carmine into the extravascular space in the systemic circulation.

  6. Comparative analysis of two methods for measuring sales volumes during malaria medicine outlet surveys.

    Science.gov (United States)

    Patouillard, Edith; Kleinschmidt, Immo; Hanson, Kara; Pok, Sochea; Palafox, Benjamin; Tougher, Sarah; O'Connell, Kate; Goodman, Catherine

    2013-09-05

    There is increased interest in using commercial providers for improving access to quality malaria treatment. Understanding their current role is an essential first step, notably in terms of the volume of diagnostics and anti-malarials they sell. Sales volume data can be used to measure the importance of different provider and product types, frequency of parasitological diagnosis and impact of interventions. Several methods for measuring sales volumes are available, yet all have methodological challenges and evidence is lacking on the comparability of different methods. Using sales volume data on anti-malarials and rapid diagnostic tests (RDTs) for malaria collected through provider recall (RC) and retail audits (RA), this study measures the degree of agreement between the two methods at wholesale and retail commercial providers in Cambodia following the Bland-Altman approach. Relative strengths and weaknesses of the methods were also investigated through qualitative research with fieldworkers. A total of 67 wholesalers and 107 retailers were sampled. Wholesale sales volumes were estimated through both methods for 62 anti-malarials and 23 RDTs and retail volumes for 113 anti-malarials and 33 RDTs. At wholesale outlets, RA estimates for anti-malarial sales were on average higher than RC estimates (mean difference of four adult equivalent treatment doses (95% CI 0.6-7.2)), equivalent to 30% of mean sales volumes. For RDTs at wholesalers, the between-method mean difference was not statistically significant (one test, 95% CI -6.0-4.0). At retail outlets, between-method differences for both anti-malarials and RDTs increased with larger volumes being measured, so mean differences were not a meaningful measure of agreement between the methods. Qualitative research revealed that in Cambodia where sales volumes are small, RC had key advantages: providers were perceived to remember more easily their sales volumes and find RC less invasive; fieldworkers found it more

  7. The effect of breath alcohol simulator solution volume on measurement results.

    Science.gov (United States)

    Speck, P R; McElroy, A J; Gullberg, R G

    1991-01-01

    Breath alcohol simulator devices (simulators) containing alcohol and water solutions are used to calibrate and test breath-testing instruments. The manufacturers of simulators design them to contain 500 mL of solution. This study evaluated the variability observed among three different groups of data: one group (experimental) in which the solution volume varied from 400 mL to 600 mL, one group (control) in which the simulator volume remained constant at 500 mL for each aliquot, and finally one group consisting of field simulator measurements collected over time. The infrared breath test instrument employed was a BAC Verifier Datamaster. A one-way analysis of variance and the Cochran's C for equal variances were applied to the data. The results indicated that when the solution volume remained at 500 mL, there was nearly as much or greater within-run variability as when the volumes were varied from 400 mL to 600 mL. Both the experimental and control groups showed statistical significance for the one-way ANOVA and were considered within-run measurements. The high within-run instrumental precision (CV approx. 1%) probably accounts for these results. The field data, considered between-day measurements, had larger within-group variability and resulted in a nonsignificant ANOVA. Small variations from the 500-mL volume in a simulator do not result in a statistically significant difference where between-day measurements are evaluated.

  8. Thyroid and menopause.

    Science.gov (United States)

    del Ghianda, S; Tonacchera, M; Vitti, P

    2014-06-01

    Thyroid dysfunction is common in the general population especially in women. All thyroid diseases are in fact more common in women than in men and may interfere with the reproductive system. Thyroid function and the gonadal axes are related throughout the woman's fertile period. The relationship between the two glands is mutual. In particular, thyroid hormones affect the reproductive function both directly and indirectly through several actions. Studies on the relationship between menopause and thyroid function are few and do not allow to clarify whether menopause has an effect on the thyroid regardless of aging. With aging, the main changes regarding thyroid physiology and function are: a reduction of thyroid iodine uptake, free thyroxine and free triiodothyronine synthesis and catabolism of free thyroxine while reverse triiodothyronine increases; the level of thyroid stimulating hormone remains normal with sometimes a tendency to higher limits. These changes are present in both sexes without distinction between males and females. The complexity of the relationships can be summarized in three aspects: thyroid status does not influence significantly the climacteric syndrome; menopause may modify the clinical expression of some thyroid diseases, particularly the autoimmune ones; thyroid function is not directly involved in the pathogenesis of the complications of menopause. However, coronary atherosclerosis and osteoporosis may be aggravated in the presence of hyperthyroidism or hypothyroidism. The effects of postmenopausal estrogen replacement on thyroxine requirements in women with hypothyroidism should be considered.

  9. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the structure and function of the thyroid. The thyroid is a gland in the neck that controls metabolism , a chemical process that regulates the rate at which the body converts food to energy. top of page What are some common uses of the procedure? The thyroid scan is used to determine the size, shape ...

  10. Does thyroid gland examination by palpation alter serum hormone levels?

    Science.gov (United States)

    Toros, Sema Zer; Ozel, Leyla; Yekrek, Mehmet Murat; Toros, Ahmet Burak; Naiboglu, Baris; Kara, Melih; Erdoğdu, Erdal; Egeli, Erol; Titiz, Izzet

    2010-07-01

    The goal of this study was to investigate the effects of routine thyroid gland palpation on serum thyroid hormone levels. Prospective study at Haydarpaşa Numune Research and Education Hospital, Istanbul, Turkey. This study was carried out in two groups with a total of 50 consecutive adults. Group I consisted of 20 patients (12 female and 8 male, aged 20-48 years) with a diagnosis of nodular thyroid disease confirmed by ultrasound imaging techniques. The second group consisted of 30 otherwise healthy subjects (17 female and 13 male, aged 18-50 years) referred for neck and thyroid ultrasound and with no thyroid pathology detected. Thyroid gland palpations were performed by the same physician. Blood samples were obtained before and 2 hours after thyroid gland palpation. Serum total T3 (TT3), total T4 (TT4), free T3 (FT3), free T4 (FT4), thyroid stimulating hormone (TSH), and thyroglobulin (TG) measurements were made. We found that routine palpation in the first group caused a significant increase in serum TT3 (P .05). Preliminary data proposing a possible effect of routine thyroid gland palpation on serum thyroid hormone levels suggest that serum thyroid hormone measurements should be performed before any manipulation of the gland, including palpation, to avoid misdiagnosis.

  11. Correlation Between Computed Tomography Density and Functional Status of the Thyroid Gland.

    Science.gov (United States)

    Pandey, Vivek; Reis, Martin; Zhou, Yihua

    2016-01-01

    This study aimed to determine the correlation between thyroid computed tomography (CT) density and thyroid functional status. Thyroid CT densities were determined in patients who had a noncontrast CT of the cervical spine and a recent thyroid-stimulating hormone (TSH) measurement in a cohort of 157 patients. Thyroid CT densities of patients with abnormally low TSH and high TSH were compared to those with normal TSH. A correlation analysis was performed to determine the correlation between TSH levels and CT densities. Both low and high TSH groups demonstrated significantly decreased thyroid CT densities (P thyroid CT densities and TSH levels (r = 0.40; P thyroid CT density and serum TSH levels. A low thyroid CT density indicates abnormal thyroid function.

  12. Three-dimensional placental volume measurements between 11 and 13 weeks' gestation.

    Science.gov (United States)

    Burstein, Eliezer; Sheiner, Eyal; Hershkovitz, Reli

    2009-02-01

    We sought to determine whether three-dimensional (3D) placental volume measurements can be assessed in normal pregnancies between 11 and 13 weeks' gestation with good intraobserver accuracy. Twenty normal pregnancies were included. Placental volume was determined twice, using the virtual organ computer-aided analysis method. Three-dimensional placental volume measurements were performed by a single physician. Patients with multiple pregnancies, first-trimester bleeding, and abnormal placental appearance were excluded. Intraobserver reliability was evaluated by kappa analysis, and Student T test was performed for continuous variables. Mean placental volume (MPV) was 67.5 +/- 26.7 mL (3) between 11 and 13 weeks' gestation. No significant differences were noted between the two examinations performed (MPV of 67.5 +/- 26.7 mL (3) during the first versus 65.6 +/- 29.1 mL (3) during the second examination; p = 0.826). Moreover, the intraobserver agreement was excellent as indicated by kappa of 0.8. Placental volume can be assessed by 3D sonography between 11 and 13 weeks' gestation with minimal deviations. Nevertheless, the broad variability in placental volume with a wide standard deviation makes its clinical significance questionable.

  13. MRI-Based Measurement of Hippocampal Volume in Patients With Combat-Related Posttraumatic Stress Disorder

    Science.gov (United States)

    Bremner, J. Douglas; Randall, Penny; Scott, Tammy M.; Bronen, Richard A.; Seibyl, John P.; Southwick, Steven M.; Delaney, Richard C.; McCarthy, Gregory; Charney, Dennis S.; Innis, Robert B.

    2011-01-01

    Objective Studies in nonhuman primates suggest that high levels of cortisol associated with stress have neurotoxic effects on the hippocampus, a brain structure involved in memory. The authors previously showed that patients with combat-related posttraumatic stress disorder (PTSD) had deficits in short-term memory. The purpose of this study was to compare the hippocampal volume of patients with PTSD to that of subjects without psychiatric disorder. Method Magnetic resonance imaging was used to measure the volume of the hippocampus in 26 Vietnam combat veterans with PTSD and 22 comparison subjects selected to be similar to the patients in age, sex, race, years of education, socioeconomic status, body size, and years of alcohol abuse. Results The PTSD patients had a statistically significant 8% smaller right hippocampal volume relative to that of the comparison subjects, but there was no difference in the volume of other brain regions (caudate and temporal lobe). Deficits in short-term verbal memory as measured with the Wechsler Memory Scale were associated with smaller right hippocampal volume in the PTSD patients only. Conclusions These findings are consistent with a smaller right hippocampal volume in PTSD that is associated with functional deficits in verbal memory. PMID:7793467

  14. Analysis of measurement process of placental volume in early pregnancy: an interobserver reliability study.

    Science.gov (United States)

    Florido, Jesús; Ocón, Olga; Luna del Castillo, Juan de Dios; Vega-Cañadas, Javier; Manrique-Espinoza, Nadya; Navarrete, Luis

    2014-09-01

    To examine concordance among results obtained in measurement process of first-trimester placental volume using 3D ultrasound and eXtended Imaging Virtual Organ Computed-aided AnaLysis (XI-VOCAL®, 3DXITM, Medison, Seoul, Korea) image analysis by three different operators. Twenty first-trimester normal pregnancy cases were selected for placental volume measuring using a Medison SA 8000 Live Prime® (Medison, Seoul, Korea) with a convex volumetric multifrequency abdominal probe. Images were processed and studied independently by three operators with different grade of training. Each operator obtained 50 slices per case. Thus, this study is based on 1000 measurements that have generated four different sets of placental volume determinations based on 5, 10, 15, and 20 slices, respectively. Results of measurement process were analyzed using reliability coefficients. There was a good degree of concordance in the placental length values obtained by all operators and not depend from the number of cuts measured [intraclass correlation coefficient (ICC)=0.734]. However, the number of cuts is important to obtain a placental volume with more accuracy. Reliability coefficients were low when determining placental volume adjusted to placental length (ICC=0.293), but combined results of the two operators that were trained in the same way showed higher coefficients of reliability (ICC=0.682), and therefore, greater concordance when comparing with the operator that was not trained in the same way. Higher coefficients of reliability guarantee high grades of concordance in the results among operators when measuring placental volumes independently, however, contouring process introduces high variability. Training in how to best use the image analysis software effectively assists in getting higher coefficients of reliability.

  15. Measurement of testicular volume in smaller testes: how accurate is the conventional orchidometer?

    Science.gov (United States)

    Lin, Chih-Chieh; Huang, William J S; Chen, Kuang-Kuo

    2009-01-01

    The aim of this study was to evaluate the accuracy of different methods, including the Seager orchidometer (SO) and ultrasonography (US), for assessing testicular volume of smaller testes (testes volume less than 18 mL). Moreover, the equations used for the calculations--the Hansen formula (length [L] x width [W](2) x 0.52, equation A), the prolate ellipsoid formula (L x W x height [H] x 0.52, equation B), and the Lambert equation (L x W x H x 0.71, equation C)--were also examined and compared with the gold standard testicular volume obtained by water displacement (Archimedes principle). In this study, 30 testes from 15 men, mean age 75.3 (+/-8.3) years, were included. They all had advanced prostate cancer and were admitted for orchiectomy. Before the procedure, all the testes were assessed using SO and US. The dimensions were then input into each equation to obtain the volume estimates. The testicular volume by water displacement was 8.1 +/- 3.5 mL. Correlation coefficients (R(2)) of the 2 different methods (SO, US) to the gold standard were 0.70 and 0.85, respectively. The calculated testicular volumes were 9.2 +/- 3.9 mL (measured by SO, equation A), 11.9 +/- 5.2 mL (measured by SO, equation C), 7.3 +/- 4.2 mL (measured by US, equation A), 6.5 +/- 3.3 mL (measured by US, equation B) and 8.9 +/- 4.5 mL (measured by US, equation C). Only the mean size measured by US and volume calculated with the Hansen equation (equation A) and the mean size measured by US and volume calculated with the Lambert equation (equation C) showed no significant differences when compared with the volumes estimated by water displacement (mean difference 0.81 mL, P = .053, and 0.81 mL, P = .056, respectively). Based on our measurements, we categorized testicular volume by different cutoff values (7.0 mL, 7.5 mL, 8.0 mL, and 8.5 mL) to calculate a new constant for use in the Hansen equation. The new constant was 0.59. We then reexamined the equations using the new 0.59 constant, and found

  16. Limitations of intraoperative adrenal remnant volume measurement in patients undergoing subtotal adrenalectomy.

    Science.gov (United States)

    Brauckhoff, Michael; Stock, Karsten; Stock, Susanne; Lorenz, Kerstin; Sekulla, Carsten; Brauckhoff, Katrin; Thanh, Phuong Nguyen; Gimm, Oliver; Spielmann, Rolf Peter; Dralle, Henning

    2008-05-01

    Recent studies have shown that a minimum of approximately one-third of one normal adrenal gland is required for sufficient adrenocortical stress capacity. Correlation between intraoperative measurement, determination of remnant size by computed tomography (CT), and adrenocortical stress capacity has not been examined so far. Twenty-two patients with familial pheochromocytoma (n=13), sporadic pheochromocytoma (n=3), and adrenocortical tumors (n=6) who underwent unilateral or bilateral subtotal adrenalectomy (STAE, 28 adrenal remnants) were prospectively studied. Patients were examined in a multi-slice CT to determine residual adrenal tissue and by ACTH test 4 days and 3 months postoperatively. There was a slight significant correlation between intraoperative and CT calculated volumes (r=0.77; pSTAE has limitations. CT gives larger volumes compared with intraoperative determination. For calculation of a volume-function correlation of residual adrenal tissue, in clinical practice, the determination of relative adrenal residual volume is acceptable.

  17. A Comparison of Gender and Socioeconomic Bracket in Fourth Grade Students when Measuring Volume

    Science.gov (United States)

    Jennings, Kelly A.

    The goal of this study was to assess students' abilities when measuring volume as well as providing a hands-on method for designing a water-filtration process. I studied the trends among gender, time, and ability to measure water in two different groups of fourth grade students. Fourth grade students from both higher income and lower income school districts visited a STEM (Science, Technology, Engineering, and Mathematics) Studio in order to participate in hands-on, problem-based learning. The students in this study attempted to solve the "Dirty Water Problem" by measuring 281ml of dirty water solution, and using household tools to filter and clean the dirty water. This study showed that 68% of students from a high-income socioeconomic bracket were able to measure a determined volume of water independently. Meanwhile, only 18% of students from a low-income socioeconomic bracket were able to complete the same task independently. In the low-income bracket, 78% of students required assistance measuring a volume of water, indicating that the majority of these students performed below grade level. Where time spent at the station was concerned, the difference between high-income and low-income socioeconomic brackets was insignificant. Key Words: STEM, measurement, volume, design, Dirty Water Problem, socioeconomic bracket.

  18. Mechanisms of thallium-201 accumulation to thyroid gland

    International Nuclear Information System (INIS)

    Kishida, Toshihiro

    1987-01-01

    In this study 91 patients with goiter were scintigraphed for the duration of 84 minutes after intravenous administration of thallium-201 by digital γ camera lined to computer data system. Regions of interest (ROIs) were assigned for thyroid tumor, normal thyroid and back ground, and time-activity curves (TACs) were generated from these ROIs. Na + , K + -ATPase activity of microsome fraction from thyroid tumor and the normal thyroid glands was determined. The first 15 minutes accumulation of each ROI was determined as the early accumulation of thallium-201 for tumor and the normal thyroid glands. Papillary and follicular carcinomas, showing the high accumulation of thallium-201, had high activity of Na + , K + -ATPase. Microfollicular adenomas had high activity of Na + , K + -ATPase and demonstrated intense accumulation of thallium-201. However, colloid adenoma had a similar level of Na + , K + -ATPase activity to that of the normal thyroid glands and did not demonstrate radionuclide accumulation. Consequently, radionuclide accumulation in thallium-201 thyroid scintigraphy was closely correlated to Na + , K + -ATPase activity of thyroid tumor. Thyroid blood flow was measured by hydrogen gas clearance method. Thyroid blood flow of papillary carcinoma was smaller, as compared with normal thyroid blood flow. TAC of papillary carcinoma showed flattening. Thallium-201 accumulation in early image was also found to correspond to thyroid blood flow. From this study we can conclude that mechanisms of thallium-201 accumulation in a thyroid tumor depends on Na + , K + -ATPase activity and thyroid blood flow. Washout of TAC in thallium-201 scintigraphy appears dependent on blood flow of a thyroid nodule. (author)

  19. Thyroid function in newly diagnosed HIV-infected patients.

    Science.gov (United States)

    Noureldeen, Amani Fh; Qusti, Safaa Y; Khoja, Gelan Ms

    2014-11-01

    A variety of HIV-related endocrine dysfunctions including adrenal, gonadal and thyroid disorders have been reported. We aimed to compare between the markers of thyroid function in newly diagnosed HIV-infected patients and healthy volunteers as a control group. The prevalence of the thyroid abnormalities in HIV-infected patients was assessed and the levels of thyroid autoantibodies were also determined. A total of 100 newly diagnosed HIV-infected patients having a CD4 cell count of 180-350 cells/mm(3) were enrolled in the study. Same number of healthy volunteers were also included for comparison. Measurements of thyroid function tests including thyroid-stimulating hormone (TSH), free thyroxin and free triiodothyronine levels beside thyroid autoantibodies, including antithyroglobulin (ATBG) and antithyroid peroxidase (ATPO), were carried out for all patients and volunteers. In total, 70% of HIV-infected patients had normal thyroid function tests when compared with control individuals, while 30% of HIV-infected patients had abnormal thyroid function. Of the 30 cases, 11 cases had abnormal TSH values, with increased TSH predominant (7% of HIV cases) than decreased TSH (4% of patients) values. Incidence of thyroid abnormalities ranging from hypothyroidism (subclinical and overt: 6% and 1%, respectively) to hyperthyroidism (2%) and nonthyroidal illness (9%) were estimated in HIV-infected patients. The values of thyroid autoantibodies were almost normal in HIV-infected patients, except the three cases presented with elevated ATBG, indicating that thyroid abnormalities were not due to elevated ATBG and ATPO. Thyroid hormones are of great importance and due to high prevalence of thyroid function abnormality, it is recommended that thyroid function tests should be monitored in all HIV-infected patients before starting the treatment. © The Author(s) 2012.

  20. Unexpected Elevated Free Thyroid Hormones in Pregnancy.

    Science.gov (United States)

    Teti, Claudia; Nazzari, Elena; Galletti, Marina Raffaella; Mandolfino, Mattia Grazia; Pupo, Francesca; Pesce, Giampaola; Lillo, Flavia; Bagnasco, Marcello; Benvenga, Salvatore

    2016-11-01

    The use of thyrotropin and free thyroid hormone assays to evaluate thyroid function is widespread, but in some situations the results are inconsistent with the patient's thyroid status. A 35-year-old woman with a known diagnosis of chronic autoimmune thyroiditis was referred to the authors' clinic at week 26 of her second pregnancy. The patient was clinically euthyroid. Consistent with this, her serum thyrotropin (TSH) was normal (0.79 mIU/L), but she had elevated free thyroid hormones-free triiodothyronine (fT3) and free thyroxine (fT4)-as determined by a one-step chemiluminescent assay. The patient was taking levothyroxine replacement therapy (125 μg/day), and the dose was confirmed. Previous blood tests showed concordance between TSH and free thyroid hormone values. The patient was followed up throughout gestation and at 12 months postpartum. During gestation, her free thyroid hormones remained high using one-step methods, while the total thyroid hormone concentration values were within the reference range, in agreement with the TSH values. Postpartum fT4 and fT3 values returned progressively to normality, in agreement with the TSH values. The presence of circulating thyroid hormone autoantibodies (THAb) was hypothesized, which are known to interfere, although to a variable extent, with thyroid hormone one-step assays. Using stored frozen sera, this hypothesis was confirmed indirectly by measuring normal levels of fT3 and fT4 with a two-step method, and directly by demonstrating THAb against the two hormones. Despite their relative rarity, circulating THAb may be suspected when laboratory data are not consistent and contrast with the clinical picture. To the authors' knowledge, no previous case of transient appearance of THAb in pregnancy has been described.

  1. Measuring sound absorption properties of porous materials using a calibrated volume velocity source

    International Nuclear Information System (INIS)

    Arenas, Jorge P; Darmendrail, Luis

    2013-01-01

    Measurement of acoustic properties of sound-absorbing materials has been the source of much investigation that has produced practical measuring methods. In particular, the measurement of the normal incidence sound absorption coefficient is commonly done using a well-known configuration of a tube carrying a plane wave. The sound-absorbing coefficient is calculated from the surface impedance measured on a sample of material. Therefore, a direct measurement of the impedance requires knowing the ratio between the sound pressure and the volume velocity. However, the measurement of volume velocity is not straightforward in practice and many methods have been proposed including complex transducers, laser vibrometry, accelerometers and calibrated volume velocity sources. In this paper, a device to directly measure the acoustic impedance of a sample of sound-absorbing material is presented. The device uses an internal microphone in a small cavity sealed by a loudspeaker and a second microphone mounted in front of this source. The calibration process of the device and the limitations of the method are also discussed and measurement examples are presented. The accuracy of the device was assessed by direct comparison with the standardized method. The proposed measurement method was tested successfully with various types of commercial acoustic porous materials. (paper)

  2. Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956)- An Assessment of Quantities released, Off-Site Radiation Doses, and Potential Excess Risks of Thyroid Cancer- APPENDICES Appendices-Volume 1A

    International Nuclear Information System (INIS)

    Apostoaei, A.I.; Burns, R.E.; Hoffman, F.O.; Ijaz, T.; Lewis, C.J.; Nair, S.K.; Widner, T.E.

    1999-01-01

    This report consists of all the appendices for the report described below: In the early 1990s, concern about the Oak Ridge Reservation's past releases of contaminants to the environment prompted Tennessee's public health officials to pursue an in-depth study of potential off-site health effects at Oak Ridge. This study, the Oak Ridge dose reconstruction, was supported by an agreement between the U.S. Department of Energy (DOE) and the State of Tennessee, and was overseen by a 12-member panel appointed by Tennessee's Commissioner of Health. One of the major contaminants studied in the dose reconstruction was radioactive iodine, which was released to the air by X-10 (now called Oak Ridge National Laboratory) as it processed spent nuclear reactor fuel from 1944 through 1956. The process recovered radioactive lanthanum for use in weapons development. Iodine concentrates in the thyroid gland so health concerns include various diseases of the thyroid, such as thyroid cancer. The large report, ''Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956) - An Assessment of Quantities Released, Off-site Radiation Doses, and Potential Excess Risks of Thyroid Cancer,'' is in two volumes. Volume 1 is the main body of the report, and Volume 1A, which has the same title, consists of 22 supporting appendices. Together, these reports serve the following purposes: (1) describe the methodologies used to estimate the amount of iodine-131 (I-131) released; (2) evaluate I-131's pathway from air to vegetation to food to humans; (3) estimate doses received by human thyroids; (4) estimate excess risk of acquiring a thyroid cancer during ones lifetime; and (5) provide equations, examples of historical documents used, and tables of calculated values as appendices. Results indicate that females born in 1952 who consumed milk from a goat pastured a few miles east of X-10 received the highest doses from I-131 and would have had the highest

  3. Measurement of Post Void Residual Urine Volume Using Portable 3D Ultrasound Compared with Urinary Catheterization

    Directory of Open Access Journals (Sweden)

    Pichai Leerasiri

    2017-05-01

    Full Text Available Objective: To find out correlation between the 3D ultrasound and conventional urethral catheterization in terms of measurement accuracy of post void residual urine (PVR volume, pain score, and elapsed time among patients attending Urogynecology Clinic, Siriraj Hospital between December 2011 to December 2012. Methods: With the approval of the institution’s Ethics Committees, a total of 64 participants were enrolled. Participants with conditions that could affect bladder volume, including previous pelvic surgery and radiation, abnormal anatomy of genitourinary system, and contraindications for urethral catheterization were excluded. A questionnaire asking about demographic data and clinical presentation of each participant was completed. PVR volume was measured using the BladderScan® (BVI-9400, followed by urethral catheterization. Differences between PVR volume and elapsed time in both procedures were determined. At the end of each procedure every participant was asked to rate the pain score, from 0 (no pain to 10 (most severe pain, according to the Visual Analog Scale. Results: The mean age was 60 years old, ranging from 33 to 81. The mean body mass index (BMI was 26.5 kg/m2± 4.1. The PVR volume measured by the BladderScan® was significantly correlated with that measured by the conventional catheterization with the correlation coefficient of 0.92 (p<0.001. The mean pain score in the BladderScan® group was obviously less when compared with that of the catheterization group (0.59 ± 1.19 vs 3.00 ± 2.07; p<0.001. The mean time used in the BladderScan® group was significantly lower than that in the catheterization group. Conclusion: The BladderScan® had high correlation, time saving and less pain compared to conventional urethral catheterization for measurement of the post-void residual urine volume.

  4. Measurement of the dose to the family members taking care of thyroid cancer patients undergoing I-131 therapy in nuclear medicine using TLD-100

    International Nuclear Information System (INIS)

    Zehtabian, M.; Dehghan, N.; Danaei Ghazanfarkhani, M.; Haghighatafshar, M.; Sina, S.

    2017-01-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by 131 I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commissions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. (authors)

  5. Comparison of the measured radiation dose-rate by the ionization chamber and G (Geiger-Mueller) counter after radioactive lodine therapy in differentiated thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Hun [Dept. of Nuclear Medicine, Kyungbuk National University Hospital, Daegu (Korea, Republic of); Kim, Kgu Hwan [Dept. of Radiological Technology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    Radioactive iodine(131I) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

  6. AFM-porosimetry: density and pore volume measurements of particulate materials.

    Science.gov (United States)

    Sörensen, Malin H; Valle-Delgado, Juan J; Corkery, Robert W; Rutland, Mark W; Alberius, Peter C

    2008-06-01

    We introduced the novel technique of AFM-porosimetry and applied it to measure the total pore volume of porous particles with a spherical geometry. The methodology is based on using an atomic force microscope as a balance to measure masses of individual particles. Several particles within the same batch were measured, and by plotting particle mass versus particle volume, the bulk density of the sample can be extracted from the slope of the linear fit. The pore volume is then calculated from the densities of the bulk and matrix materials, respectively. In contrast to nitrogen sorption and mercury porosimetry, this method is capable of measuring the total pore volume regardless of pore size distribution and pore connectivity. In this study, three porous samples were investigated by AFM-porosimetry: one ordered mesoporous sample and two disordered foam structures. All samples were based on a matrix of amorphous silica templated by a block copolymer, Pluronic F127, swollen to various degrees with poly(propylene glycol). In addition, the density of silica spheres without a template was measured by two independent techniques: AFM and the Archimedes principle.

  7. Metabolic tumour volumes measured at staging in lymphoma: methodological evaluation on phantom experiments and patients

    International Nuclear Information System (INIS)

    Meignan, Michel; Sasanelli, Myriam; Itti, Emmanuel; Casasnovas, Rene Olivier; Luminari, Stefano; Fioroni, Federica; Coriani, Chiara; Masset, Helene; Gobbi, Paolo G.; Merli, Francesco; Versari, Annibale

    2014-01-01

    The presence of a bulky tumour at staging on CT is an independent prognostic factor in malignant lymphomas. However, its prognostic value is limited in diffuse disease. Total metabolic tumour volume (TMTV) determined on 18 F-FDG PET/CT could give a better evaluation of the total tumour burden and may help patient stratification. Different methods of TMTV measurement established in phantoms simulating lymphoma tumours were investigated and validated in 40 patients with Hodgkin lymphoma and diffuse large B-cell lymphoma. Data were processed by two nuclear medicine physicians in Reggio Emilia and Creteil. Nineteen phantoms filled with 18 F-saline were scanned; these comprised spherical or irregular volumes from 0.5 to 650 cm 3 with tumour-to-background ratios from 1.65 to 40. Volumes were measured with different SUVmax thresholds. In patients, TMTV was measured on PET at staging by two methods: volumes of individual lesions were measured using a fixed 41 % SUVmax threshold (TMTV 41 ) and a variable visually adjusted SUVmax threshold (TMTV var ). In phantoms, the 41 % threshold gave the best concordance between measured and actual volumes. Interobserver agreement was almost perfect. In patients, the agreement between the reviewers for TMTV 41 measurement was substantial (ρ c = 0.986, CI 0.97 - 0.99) and the difference between the means was not significant (212 ± 218 cm 3 for Creteil vs. 206 ± 219 cm 3 for Reggio Emilia, P = 0.65). By contrast the agreement was poor for TMTV var . There was a significant direct correlation between TMTV 41 and normalized LDH (r = 0.652, CI 0.42 - 0.8, P 41 , but high TMTV 41 could be found in patients with stage 1/2 or nonbulky tumour. Measurement of baseline TMTV in lymphoma using a fixed 41% SUVmax threshold is reproducible and correlates with the other parameters for tumour mass evaluation. It should be evaluated in prospective studies. (orig.)

  8. Thyroglossal Duct Papillary Thyroid Carcinoma and Synchronous Lingual Thyroid Atypia

    Directory of Open Access Journals (Sweden)

    Timothy Yoo

    2016-01-01

    Full Text Available Thyroglossal duct and lingual thyroid ectopic lesions are exceedingly rare synchronous findings. Papillary thyroid carcinoma of these ectopic thyroid sites is well understood but still a rare finding. This case points to some management nuances in regard to ectopic thyroid screening with imaging and also shows the effectiveness of minimally invasive transoral robotic surgery for lingual thyroid.

  9. Ultrasonic methods for measuring liquid viscosity and volume percent of solids

    Energy Technology Data Exchange (ETDEWEB)

    Sheen, S.H.; Chien, H.T.; Raptis, A.C.

    1997-02-01

    This report describes two ultrasonic techniques under development at Argonne National Laboratory (ANL) in support of the tank-waste transport effort undertaken by the U.S. Department of Energy in treating low-level nuclear waste. The techniques are intended to provide continuous on-line measurements of waste viscosity and volume percent of solids in a waste transport line. The ultrasonic technique being developed for waste-viscosity measurement is based on the patented ANL viscometer. Focus of the viscometer development in this project is on improving measurement accuracy, stability, and range, particularly in the low-viscosity range (<30 cP). A prototype instrument has been designed and tested in the laboratory. Better than 1% accuracy in liquid density measurement can be obtained by using either a polyetherimide or polystyrene wedge. To measure low viscosities, a thin-wedge design has been developed and shows good sensitivity down to 5 cP. The technique for measuring volume percent of solids is based on ultrasonic wave scattering and phase velocity variation. This report covers a survey of multiple scattering theories and other phenomenological approaches. A theoretical model leading to development of an ultrasonic instrument for measuring volume percent of solids is proposed, and preliminary measurement data are presented.

  10. Ultrasonic methods for measuring liquid viscosity and volume percent of solids

    International Nuclear Information System (INIS)

    Sheen, S.H.; Chien, H.T.; Raptis, A.C.

    1997-02-01

    This report describes two ultrasonic techniques under development at Argonne National Laboratory (ANL) in support of the tank-waste transport effort undertaken by the U.S. Department of Energy in treating low-level nuclear waste. The techniques are intended to provide continuous on-line measurements of waste viscosity and volume percent of solids in a waste transport line. The ultrasonic technique being developed for waste-viscosity measurement is based on the patented ANL viscometer. Focus of the viscometer development in this project is on improving measurement accuracy, stability, and range, particularly in the low-viscosity range (<30 cP). A prototype instrument has been designed and tested in the laboratory. Better than 1% accuracy in liquid density measurement can be obtained by using either a polyetherimide or polystyrene wedge. To measure low viscosities, a thin-wedge design has been developed and shows good sensitivity down to 5 cP. The technique for measuring volume percent of solids is based on ultrasonic wave scattering and phase velocity variation. This report covers a survey of multiple scattering theories and other phenomenological approaches. A theoretical model leading to development of an ultrasonic instrument for measuring volume percent of solids is proposed, and preliminary measurement data are presented

  11. Hemoglobin-Dilution Method: Effect of Measurement Errors on Vascular Volume Estimation

    Directory of Open Access Journals (Sweden)

    Matthew B. Wolf

    2017-01-01

    Full Text Available The hemoglobin-dilution method (HDM has been used to estimate changes in vascular volumes in patients because direct measurements with radioisotopes are time-consuming and not practical in many facilities. The HDM requires an assumption of initial blood volume, repeated measurements of plasma hemoglobin concentration, and the calculation of the ratio of hemoglobin measurements. The statistics of these ratio distributions resulting from measurement error are ill-defined even when the errors are normally distributed. This study uses a “Monte Carlo” approach to determine the distribution of these errors. The finding was that these errors could be closely approximated with a log-normal distribution that can be parameterized by a geometric mean (X and a dispersion factor (S. When the ratio of successive Hb concentrations is used to estimate blood volume, normally distributed hemoglobin measurement errors tend to produce exponentially higher values of X and S as the SD of the measurement error increases. The longer tail of the distribution to the right could produce much greater overestimations than would be expected from the SD values of the measurement error; however, it was found that averaging duplicate and triplicate hemoglobin measurements on a blood sample greatly improved the accuracy.

  12. Measurement of testicular volume in Wistar rats using a caliper and ultrasonography in experimental surgery.

    Science.gov (United States)

    Brêtas, Salomão; Tatsuo, Edson Samesima; Brêtas, Monica Odete Oliveira; Brêtas, Caroline Oliveira

    2016-07-01

    To compare the measurement of the testicular volume of Wistar rats using a caliper and ultrasonography. Forty Wistar rats were randomly assigned into four groups. A tensile force of 1.6 Newton (N) and 1.0 N was applied to the right spermatic cord in group I and group II, respectively. Group III was the sham group, and group IV served as a control. The initial and final testicular volumes were measured using a caliper and ultrasonography and compared. A significance level of 5% was used. The Kappa coefficient was equal to 0.292 (p = 0.006). The Pearson correlation coefficient obtained for the percent reduction in the right testicular volume using ultrasonography and a caliper was equal to 0.696 (p caliper.

  13. Development of ultrasonic velocity profile method for flow rate measurements of power plant (effect of measurement volume on turbulent flow measurement)

    International Nuclear Information System (INIS)

    Hiroshige, Kikura; Gentaro, Yamanaka; Tsuyoshi, Taishi; Masanori, Aritomi; Yasushi, Takeda; Michitsugu, Mori

    2001-01-01

    Ultrasonic Velocity Profile method has many advantages for flow rate measurement of power plant over the conventional flow measurement methods, such as measurement of the instantaneous velocity profile along the measuring line and its applicability to opaque liquids. Furthermore, the method has an advantage of being non-intrusive. Hence, it is applicable to various flow conditions, although it requires a relatively large measurement volume. In this paper, the effects of the measurement volume on the mean velocity profile for flow rate measurements of power plant and the Reynolds stress measurement have been investigated for fully developed turbulent pipe flows in a vertical pipe. The results are then compared with data obtained by Direct Numerical Simulation (DNS). (authors)

  14. Does hydration status affect MRI measures of brain volume or water content?

    Science.gov (United States)

    Meyers, Sandra M; Tam, Roger; Lee, Jimmy S; Kolind, Shannon H; Vavasour, Irene M; Mackie, Emilie; Zhao, Yinshan; Laule, Cornelia; Mädler, Burkhard; Li, David K B; MacKay, Alex L; Traboulsee, Anthony L

    2016-08-01

    To determine whether differences in hydration state, which could arise from routine clinical procedures such as overnight fasting, affect brain total water content (TWC) and brain volume measured with magnetic resonance imaging (MRI). Twenty healthy volunteers were scanned with a 3T MR scanner four times: day 1, baseline scan; day 2, hydrated scan after consuming 3L of water over 12 hours; day 3, dehydrated scan after overnight fasting of 9 hours, followed by another scan 1 hour later for reproducibility. The following MRI data were collected: T2 relaxation (for TWC measurement), inversion recovery (for T1 measurement), and 3D T1 -weighted (for brain volumes). Body weight and urine specific gravity were also measured. TWC was calculated by fitting the T2 relaxation data with a nonnegative least-squares algorithm, with corrections for T1 relaxation and image signal inhomogeneity and normalization to ventricular cerebrospinal fluid. Brain volume changes were measured using SIENA. TWC means were calculated within 14 tissue regions. Despite indications of dehydration as demonstrated by increases in urine specific gravity (P = 0.03) and decreases in body weight (P = 0.001) between hydrated and dehydrated scans, there was no measurable change in TWC (within any brain region) or brain volume between hydration states. We demonstrate that within a range of physiologic conditions commonly encountered in routine clinical scans (no pretreatment with hydration, well hydrated before MRI, and overnight fasting), brain TWC and brain volumes are not substantially affected in a healthy control cohort. J. Magn. Reson. Imaging 2016;44:296-304. © 2016 Wiley Periodicals, Inc.

  15. The error analysis of Lobular and segmental division of right liver by volume measurement.

    Science.gov (United States)

    Zhang, Jianfei; Lin, Weigang; Chi, Yanyan; Zheng, Nan; Xu, Qiang; Zhang, Guowei; Yu, Shengbo; Li, Chan; Wang, Bin; Sui, Hongjin

    2017-07-01

    The aim of this study is to explore the inconsistencies between right liver volume as measured by imaging and the actual anatomical appearance of the right lobe. Five healthy donated livers were studied. The liver slices were obtained with hepatic segments multicolor-infused through the portal vein. In the slices, the lobes were divided by two methods: radiological landmarks and real anatomical boundaries. The areas of the right anterior lobe (RAL) and right posterior lobe (RPL) on each slice were measured using Photoshop CS5 and AutoCAD, and the volumes of the two lobes were calculated. There was no statistically significant difference between the volumes of the RAL or RPL as measured by the radiological landmarks (RL) and anatomical boundaries (AB) methods. However, the curves of the square error value of the RAL and RPL measured using CT showed that the three lowest points were at the cranial, intermediate, and caudal levels. The U- or V-shaped curves of the square error rate of the RAL and RPL revealed that the lowest value is at the intermediate level and the highest at the cranial and caudal levels. On CT images, less accurate landmarks were used to divide the RAL and RPL at the cranial and caudal layers. The measured volumes of hepatic segments VIII and VI would be less than their true values, and the measured volumes of hepatic segments VII and V would be greater than their true values, according to radiological landmarks. Clin. Anat. 30:585-590, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Early kinetics of thyroid trap in normal human patients and in thyroid diseases

    International Nuclear Information System (INIS)

    Bazin, J.P.; Fragu, P.; Paola, R. di; Paola, M. di; Tubiana, M.

    1981-01-01

    A six-compartment model is proposed for the study of early iodine kinetics in the human thyroid gland including three compartments for extrathyroidal spaces. The results were compared with those obtained with an open two-compartment thyroidal model. In six euthyroid subjects the values of the unidirectional thyroid clearance and of the irreversible clearance were consistent with those generally accepted. With TSH stimulation a clear increase in the thyroidal pump effectiveness was found without an increase in the irreversible clearance. In four untreated thyrotoxic patients a tenfold increase in the unidirectional thyroid clearance was found. The unidirectional clearance remained elevated in seven patients after Carbimazole treatment and the binding rates were reduced. The six-compartment model demonstrated a rapid exit from the bound iodine compartment. In three of four goitrous patients studied, the thyroid unidirectional clearance was significantly increased. The volumes of the iodide compartments were much higher than those observed in the other groups. The method was applied to analyse the kinetics of different parts of the thyroid. (orig./MG)

  17. Tormenta tiroidea Thyroid storm

    Directory of Open Access Journals (Sweden)

    Lisette Leal Curí

    2012-12-01

    Full Text Available La tormenta tiroidea es una de las situaciones más críticas entre las emergencias endocrinas y tiene una significativa mortalidad. La etiología más común de tirotoxicosis es la enfermedad de Graves y el factor precipitante que predomina es la infección. Clínicamente se caracteriza por la disfunción de varios sistemas (termorregulador, nervioso central, gastrointestinal y cardiovascular, con niveles de hormonas tiroideas libres o totales por encima de los valores normales. El tratamiento debe tener un enfoque multidisciplinario, e incluye medidas de soporte en unidades de cuidados intensivos, normalización de la temperatura corporal, reducción de la producción y liberación de hormonas tiroideas, con antitiroideos de síntesis y yodo respectivamente, bloqueo de los efectos periféricos mediante la administración de beta-bloqueadores, y corrección del factor desencadenante. Una vez que el paciente se encuentra estable es necesario planificar una terapia definitiva que impida la recurrencia futura de la crisis tirotóxica.The thyroid storm is one of the most critical situations in the endocrine emergencies and exhibits a significant mortality rate. The most common etiology of thyrotoxicosis is Graves' disease and the predominant precipitating factor is infection. The clinical characteristics are dysfunction of several systems (heat-regulator, central nervous, gastrointestinal and cardiovascular, and levels of total or free thyroid hormones that exceed the normal values. The treatment must be multidisciplinary and include support measures in intensive care units, normalization of body temperature, reduction of the production and the release of thyroid hormones by using synthesis and iodine anti-thyroid products respectively, blockade of the peripheral effects through administration of Beta-blockers and correction of the unleashing factor. Once the patients are stabilized, it is necessary to plan the final therapy that will prevent the

  18. Technical Note: Stored grain volume measurement using a low density point cloud

    Science.gov (United States)

    The mass of stored grain is often determined from volume measurements by crop insurers, government auditors, and stored grain managers conducting inventories. Recent increases in bin size have accentuated the difficulty of accounting for irregularities and variations in surface conditions in calcula...

  19. Effect of cigarette smoke on the measured equivalent volume activity of 222Rn in air

    International Nuclear Information System (INIS)

    Tuckova, S.; Tykva, R.

    1994-01-01

    The effect of cigarette smoke in air on the increase of the measured equivalent volume activity of 222 Rn is demonstrated. After introduction of the smoke from one cigarette into 1 m 3 of air, this value increased up to ten times as shown be the method of sucking air through a filter. (author) 5 refs.; 1 fig

  20. Legacy tree data: A national database of detailed tree measurements for volume, weight, and physical properties

    Science.gov (United States)

    P.J. Radtke; D.M. Walker; A.R. Weiskittel; J. Frank; J.W. Coulston; J.A. Westfall

    2015-01-01

    Forest mensurationists in the United States have expended considerable effort over the past century making detailed observations of trees’ dimensions. In recent decades efforts have focused increasingly on weights and physical properties. Work is underway to compile original measurements from past volume, taper, and weight or biomass studies for North American tree...

  1. Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration

    DEFF Research Database (Denmark)

    Nielsen, Jan Møller; Kristiansen, Steen B; Ringgaard, Steffen

    2007-01-01

    of the hypertonic saline bolus was inferior to injection into the pulmonary artery as a calibration method. Calibration with an independent measurement of stroke volume decreased the agreement with V(MRI). Correction for an increase in blood conductivity during the in vivo experiments improved estimation of EDV...

  2. Kidney volume measurement methods for clinical studies on autosomal dominant polycystic kidney disease

    Science.gov (United States)

    Sharma, Kanishka; Caroli, Anna; Quach, Le Van; Petzold, Katja; Bozzetto, Michela; Serra, Andreas L.; Remuzzi, Giuseppe; Remuzzi, Andrea

    2017-01-01

    Background In autosomal dominant polycystic kidney disease (ADPKD), total kidney volume (TKV) is regarded as an important biomarker of disease progression and different methods are available to assess kidney volume. The purpose of this study was to identify the most efficient kidney volume computation method to be used in clinical studies evaluating the effectiveness of treatments on ADPKD progression. Methods and findings We measured single kidney volume (SKV) on two series of MR and CT images from clinical studies on ADPKD (experimental dataset) by two independent operators (expert and beginner), twice, using all of the available methods: polyline manual tracing (reference method), free-hand manual tracing, semi-automatic tracing, Stereology, Mid-slice and Ellipsoid method. Additionally, the expert operator also measured the kidney length. We compared different methods for reproducibility, accuracy, precision, and time required. In addition, we performed a validation study to evaluate the sensitivity of these methods to detect the between-treatment group difference in TKV change over one year, using MR images from a previous clinical study. Reproducibility was higher on CT than MR for all methods, being highest for manual and semiautomatic contouring methods (planimetry). On MR, planimetry showed highest accuracy and precision, while on CT accuracy and precision of both planimetry and Stereology methods were comparable. Mid-slice and Ellipsoid method, as well as kidney length were fast but provided only a rough estimate of kidney volume. The results of the validation study indicated that planimetry and Stereology allow using an importantly lower number of patients to detect changes in kidney volume induced by drug treatment as compared to other methods. Conclusions Planimetry should be preferred over fast and simplified methods for accurately monitoring ADPKD progression and assessing drug treatment effects. Expert operators, especially on MR images, are required

  3. Gastrointestinal tract volume measurement method using a compound eye type endoscope

    Science.gov (United States)

    Yoshimoto, Kayo; Yamada, Kenji; Watabe, Kenji; Kido, Michiko; Nagakura, Toshiaki; Takahashi, Hideya; Nishida, Tsutomu; Iijima, Hideki; Tsujii, Masahiko; Takehara, Tetsuo; Ohno, Yuko

    2015-03-01

    We propose an intestine volume measurement method using a compound eye type endoscope. This method aims at assessment of the gastrointestinal function. Gastrointestinal diseases are mainly based on morphological abnormalities. However, gastrointestinal symptoms are sometimes apparent without visible abnormalities. Such diseases are called functional gastrointestinal disorder, for example, functional dyspepsia, and irritable bowel syndrome. One of the major factors for these diseases is abnormal gastrointestinal motility. For the diagnosis of the gastrointestinal tract, both aspects of organic and functional assessment is important. While endoscopic diagnosis is essential for assessment of organic abnormalities, three-dimensional information is required for assessment of the functional abnormalities. Thus, we proposed the three dimensional endoscope system using compound eye. In this study, we forces on the volume of gastrointestinal tract. The volume of the gastrointestinal tract is thought to related its function. In our system, we use a compound eye type endoscope system to obtain three-dimensional information of the tract. The volume can be calculated by integrating the slice data of the intestine tract shape using the obtained three-dimensional information. First, we evaluate the proposed method by known-shape tube. Then, we confirm that the proposed method can measure the tract volume using the tract simulated model. Our system can assess the wall of gastrointestinal tract directly in a three-dimensional manner. Our system can be used for examination of gastric morphological and functional abnormalities.

  4. Measurement of 24-hr whole-body retention of Tc-99mMDP with a thyroid uptake probe: quantitative assessment of metabolic and metastatic bone diseases

    International Nuclear Information System (INIS)

    Seto, H.; Futatsuya, R.; Kamei, T.; Furumoto, N.; Ishizaki, Y.; Hada, M.; Kakishita, M.

    1983-01-01

    A new method for measurement of 24-hr whole body retention (WBR) of Tc-99mMDP, using a thyroid uptake probe was established and its clinical significance was evaluated in 102 patients with various bone disorders, including metabolic and metastatic bone diseases, aged above 20 years old. Reproducibility of 24-hr WBR in 10 patients was very good (r=0.996). The 24-hr WBR of Tc-99mMDP in the normal subjects was 30.4 +- 4.6%. The WBR values of chronic renal failure, metastatic bone disease and hyperthyroidism groups were 98.4 +- 3.0, 44.0 +- 8.0, 40,6 +- 6.3% respectively, which were significantly higher (p < 0.001). However the WBR of steroid-induced osteoporotic group was significantly lower (17.3 +- 5.4%) as compared with the normal group (p < 0.001). Based on these results the method is simple, reproducible and accurate to measure 24-hr WBR of Tc-99mMDP. Quantification of WBR is of great clinical value to diagnose metabolic bone disease and to follow-up metabolic and metastatic bone disease after treatment

  5. LOFT experimental measurements uncertainty analyses. Volume XX. Fluid-velocity measurement using pulsed-neutron activation

    International Nuclear Information System (INIS)

    Lassahn, G.D.; Taylor, D.J.N.

    1982-08-01

    Analyses of uncertainty components inherent in pulsed-neutron-activation (PNA) measurements in general and the Loss-of-Fluid-Test (LOFT) system in particular are given. Due to the LOFT system's unique conditions, previously-used techniques were modified to make the volocity measurement. These methods render a useful, cost-effective measurement with an estimated uncertainty of 11% of reading

  6. Measurement of frontal lobe volume and thalamic volume in fetuses with congenital heart disease at different gestational weeks using three dimensional ultra sonography and its clinical value.

    Science.gov (United States)

    Li-Fei, Zhu; Hong-Xiong, Liu; Ying, H E

    2016-11-01

    Our study aimed to investigate the measurement of frontal lobe volume and thalamic volume in fetuses with congenital heart disease (CHD) at different gestational weeks using three dimensional (3-D) ultrasonography and its clinical value. Then, 238 pregnant women who received obstetric ultrasonography in ultrasound department of Internal Medicine of our hospital were enrolled between March 2013 to April 2014. In this study, 85 fetuses were diagnosed to develop CHD by prenatal fetal echocardiography, and the other 153 fetuses were normal. Frontal lobe volume, thalamic volume and cerebral blood flow was determined by color Doppler ultrasonic diagnostic apparatus (type: GE Voluson E8). The level of MCA-PI and CPR in CHD fetus group performed significantly lower than that in normal fetus group (Pfrontal lobe volume between the two groups (Pfrontal lobe volume than that in normal fetus group (Pfrontal lobe volume and thalamic volume; if gestational age frontal lobe volume and thalamic volume in fetuses with CHD performed significantly lower than that in normal fetuses.

  7. Comparison between two calibration models of a measurement system for thyroid monitoring; Comparacao entre dois modelos para calibracao de um sistema de medidas dedicado ao monitoramento de tireoide

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia [Instituto de Pesquisas Energeicas e Nucleares (IPEN), Sao Paulo, Sp (Brazil). Dept. de Metrologia das Radiacoes]. E-mail: lventur@net.ipen.br

    2005-07-01

    This paper shows a comparison between two theoretical calibration that use two mathematical models to represent the neck region. In the first model thyroid is considered to be just a region limited by two concentric cylinders whose dimensions are those of trachea and neck. The second model uses functional functions to get a better representation of the thyroid geometry. Efficiency values are obtained using Monte Carlo simulation. (author)

  8. Limitation of measurements of expiratory tidal volume and expiratory compliance under conditions of endotracheal tube leaks.

    Science.gov (United States)

    Herber-Jonat, Susanne; von Bismarck, Philipp; Freitag-Wolf, Sandra; Nikischin, Werner

    2008-01-01

    Endotracheal tube leaks (ETTLs) occur in neonates ventilated with uncuffed tubes. Assuming that the influence of ETTLs might be neglected during expiration, only expiratory tidal volume is measured for calculation of expiratory compliance in cases of large ETTLs. However, expiratory ETTL might be substantial. Therefore, we evaluated the effect of ETTL size on expiratory tidal volume and compliance. Prospective laboratory study and retrospective clinical study. University research laboratory and neonatal intensive care unit. Sixty ventilated neonates (weight 640-2160 g, gestational age 25-33 wks) were investigated. The impact of increasing ETTLs on inspiratory and expiratory measured tidal volume (Vm), corrected tidal volume (Vc), and leak volume (Vl) was investigated in a ventilated neonatal lung model. The range of ETTLs (1% to 95%) was subdivided into five groups of 12 infants each. Furthermore, the relationships between standard ETTL size and inspiratory and expiratory ETTLs were evaluated using nonlinear regression. Standard ETTL size was defined as the difference between measured inspiratory and expiratory tidal volume (Vm) related to inspiratory Vm. The size of a standard ETTL was 40% when expiratory ETTL reached 10% and was 12% when the inspiratory ETTL reached 10%. In infants, the differences between Vm and Vc were statistically significant during inspiration in the group beginning at a standard ETTL of 41% and during expiration in the group beginning at a standard ETTL of 69% (p ETTL was 33% (95% confidence interval, 28% to 36%) when expiratory ETTL reached 10% and was 13% (95% confidence interval, 12% to 15%) when inspiratory ETTL reached 10%. Expiratory Vl has a relevant impact if a certain ETTL size is reached.

  9. Mexico City air quality research initiative. Volume IV. Characterization and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Mauzy, A. [ed.

    1994-04-01

    This volume describes the methods and the data gathered in an attempt to measure and characterize the meteorological factors and the concentration of different pollutants in the Mexico City Metropolitan Area. The main objective of this document was to provide input for the simulation models and to obtain information that could be used to test and improve the models` performance. Four field campaigns were conducted, as well as routine monitoring, in order to obtain a database of atmospheric dynamics and air pollution characteristics. Sections include Airborne measurements, Remote sensing measurements, and Traditional (in situ) measurements.

  10. Machine Vision for High Precision Volume Measurement Applied to Levitated Containerless Materials Processing

    Science.gov (United States)

    Bradshaw, R. C.; Schmidt, D. P.; Rogers, J. R.; Kelton, K. F.; Hyers, R. W.

    2005-01-01

    By combining the best practices in optical dilatometry with new numerical methods, a high-speed and high precision technique has been developed to measure volume of levitated, containerlessly processed samples with sub- pixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermo-physical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermo-ophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the sub-pixel locations of sample edges and, in turn produce high precision measurements.

  11. Thyroid cancer in lingual thyroid and thyroglossal duct cyst.

    Science.gov (United States)

    Sturniolo, Giacomo; Vermiglio, Francesco; Moleti, Mariacarla

    2017-01-01

    Ectopy is the most common embryogenetic defect of the thyroid gland, representing between 48 and 61% of all thyroid dysgeneses. Persistence of thyroid tissue in the context of a thyroglossal duct remnant and lingual thyroid tissue are the most common defects. Although most cases of ectopic thyroid are asymptomatic, any disease affecting the thyroid may potentially involve the ectopic tissue, including malignancies. The prevalence of differentiated thyroid carcinoma in lingual thyroid and thyroglossal duct cyst is around 1% of patients affected with the above thyroid ectopies. We here review the current literature concerning primary thyroid carcinomas originating from thyroid tissue on thyroglossal duct cysts and lingual thyroid. Copyright © 2016 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Capillary-scale interferometry at high angles of scattering for refractive index measurements of small volumes

    Science.gov (United States)

    Świrniak, Grzegorz

    2016-04-01

    This paper focuses on the problem of elastic scattering of a collimated beam of light on an unmodified glass capillary to perform a non-destructive small volume refractive index characterization. An interaction between the beam of light and the capillary causes that a series of dark and bright fringes is formed in the far field observed at high angles of scattering. By analyzing the spatial profile of the scattered light, the absolute value of the refractive index of a small volume may be measured unambiguously.

  13. Non-invasive measurement of peritoneal dialysate volume by the X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Horiuchi, Takashi; Ohta, Y.; Tada, Yoko; Dohi, Takezumi (Tokyo Univ. (Japan). Faculty of Engineering); Azuma, N.; Matsugane, Takao; Sakurai, Hiroyuki; Mizumura, Hiroyuki; Suzuki, Mitsuru

    1991-02-01

    Graphical reconstruction of serial image data of the X-ray CT on three dialysis patients was studied to measure intraperitoneal dialysate volume. Volume estimation with a surface reconstructed model showed within 16% error while 36% error with a voxel model. However, total calculation time including data acquisition was 15 times faster with a voxel model. These results are indicative of higher relevance in clinical use of a voxel model when much clearer contour between water and tissues is obtained by improvement of software as well as the CT apparatus. (author).

  14. Long-term efficacy of current thyroid prophylaxis and future perspectives on thyroid protection during {sup 131}I-metaiodobenzylguanidine treatment in children with neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Clement, S.C. [University of Amsterdam, Department of Pediatric Endocrinology, Emma Children' s Hospital, Academic Medical Center, PO box 22660, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Oncology, Emma Children' s Hospital, Academic Medical Center, Amsterdam (Netherlands); Rijn, R.R. van [University of Amsterdam, Department of Radiology, Emma Children' s Hospital, Academic Medical Center, Amsterdam (Netherlands); Eck-Smit, B.L.F. van [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Trotsenburg, A.S.P. van [University of Amsterdam, Department of Pediatric Endocrinology, Emma Children' s Hospital, Academic Medical Center, PO box 22660, Amsterdam (Netherlands); Caron, H.N.; Tytgat, G.A.M. [University of Amsterdam, Department of Pediatric Oncology, Emma Children' s Hospital, Academic Medical Center, Amsterdam (Netherlands); Santen, H.M. van [Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Endocrinology, Utrecht (Netherlands)

    2015-04-01

    Treatment with {sup 131}I-MIBG is associated with significant thyroid damage. This study was undertaken to investigate the long-term efficacy of current thyroid prophylaxis, to explore the relationship between thyroid dysfunction and thyroid volume after exposure to {sup 131}I-MIBG and to evaluate the possible negative effects of {sup 131}I{sup -} on the parathyroid glands. Of 81 long-term surviving patients with neuroblastoma treated with {sup 131}I-MIBG during the period 1999-2012, 24 were finally evaluated. Patients received thyroxine (T4), methimazole and potassium iodide as thyroid protection. In all patients (para)thyroid function was evaluated and ultrasound investigation of the (para)thyroid gland(s) was performed. Thyroid dysfunction was defined as a plasma thyrotropin concentration >5.0 mU/L (thyrotropin elevation, TE) or as the use of T4 at the time of follow-up. Hyperparathyroidism was defined as a serum calcium concentration above the age-related reference range in combination with an inappropriately high parathyroid hormone level. At a median follow-up of 9.0 years after {sup 131}I-MIBG treatment, thyroid disorders were seen in 12 patients (50 %; 9 with TE, 5 with a thyroid nodule and 1 patient was subsequently diagnosed with differentiated thyroid carcinoma). No significant risk factors for the occurrence of thyroid damage could be identified. In 14 of 21 patients (67 %) in whom thyroid volume could be determined, the volume was considered small (<-2SD) for age and gender. Patients treated with T4 at the time of follow-up had significantly smaller thyroid volumes for age than patients without T4 treatment (p = 0.014). None of the patients was diagnosed with hyperparathyroidism. Thyroid protection during treatment with {sup 131}I-MIBG needs attention and must be further improved, as thyroid disorders are still frequently seen despite current thyroid prophylaxis. Reduced thyroid volume in neuroblastoma survivors may be related to previous {sup 131}I

  15. Long-term efficacy of current thyroid prophylaxis and future perspectives on thyroid protection during 131I-metaiodobenzylguanidine treatment in children with neuroblastoma

    International Nuclear Information System (INIS)

    Clement, S.C.; Rijn, R.R. van; Eck-Smit, B.L.F. van; Trotsenburg, A.S.P. van; Caron, H.N.; Tytgat, G.A.M.; Santen, H.M. van

    2015-01-01

    Treatment with 131 I-MIBG is associated with significant thyroid damage. This study was undertaken to investigate the long-term efficacy of current thyroid prophylaxis, to explore the relationship between thyroid dysfunction and thyroid volume after exposure to 131 I-MIBG and to evaluate the possible negative effects of 131 I - on the parathyroid glands. Of 81 long-term surviving patients with neuroblastoma treated with 131 I-MIBG during the period 1999-2012, 24 were finally evaluated. Patients received thyroxine (T4), methimazole and potassium iodide as thyroid protection. In all patients (para)thyroid function was evaluated and ultrasound investigation of the (para)thyroid gland(s) was performed. Thyroid dysfunction was defined as a plasma thyrotropin concentration >5.0 mU/L (thyrotropin elevation, TE) or as the use of T4 at the time of follow-up. Hyperparathyroidism was defined as a serum calcium concentration above the age-related reference range in combination with an inappropriately high parathyroid hormone level. At a median follow-up of 9.0 years after 131 I-MIBG treatment, thyroid disorders were seen in 12 patients (50 %; 9 with TE, 5 with a thyroid nodule and 1 patient was subsequently diagnosed with differentiated thyroid carcinoma). No significant risk factors for the occurrence of thyroid damage could be identified. In 14 of 21 patients (67 %) in whom thyroid volume could be determined, the volume was considered small (<-2SD) for age and gender. Patients treated with T4 at the time of follow-up had significantly smaller thyroid volumes for age than patients without T4 treatment (p = 0.014). None of the patients was diagnosed with hyperparathyroidism. Thyroid protection during treatment with 131 I-MIBG needs attention and must be further improved, as thyroid disorders are still frequently seen despite current thyroid prophylaxis. Reduced thyroid volume in neuroblastoma survivors may be related to previous 131 I-MIBG therapy or current T4 treatment. No

  16. Magnetic Resonance Imaging Measurement Reproducibility for Calf Muscle and Adipose Tissue Volume

    Science.gov (United States)

    Commean, Paul K.; Tuttle, Lori J.; Hastings, Mary K.; Strube, Michael J; Mueller, Michael J.

    2011-01-01

    Purpose To describe a new semi-automated method for segmenting and measuring the volume of the muscle, bone and adipose (subcutaneous and inter-muscular) tissue in calf muscle compartments using magnetic resonance (MR) images and determine the intra- rater and inter-rater reproducibility of the measures. Materials and Methods Proton-density weighted MR images were acquired from the right calf for 21 subjects. Three raters segmented and measured the volumes of bones, adipose tissue, and 5 individual muscle compartments. Two raters repeated the segmentations. The intra- and inter-rater reproducibility of the measures (intra-class correlation coefficients; ICC) were determined using generalizability theory. Results All ICC values were greater than 0.96. The average SEM of all measures was 1.21 cm3 and none were greater than 2.3 cm3. Essentially all variation (≥ 97% for all measures) was due to subject differences indicating low error in the measurements. Conclusion The volumetric measurements for the bones, adipose tissue, and muscle in each of the compartments using MR imaging were highly reproducible. MR imaging can provide quantitative, reproducible volumetric measures of bone, adipose tissue, and individual muscles in the calf. We believe these methods can be used to quantify specific muscle or adipose volumetric measures for other clinical or research purposes. PMID:21964677

  17. National intercomparison on in vivo measurement of Iodine-131 in the thyroid within a Brazilian Internal Dosimetry Laboratory Network - IAEA PROJECT BRA9055; Intercomparacao nacional de medicao in vivo de Iodo-131 na tireoide - Projeto TC IAEA BRA 9055

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, B.M.; Dantas, A.L.A.; Lucena, E.A., E-mail: bmdantas@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro (Brazil); Cardoso, J.S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ramos, M.A.P.; Sa, M.S. [Eletrobras Eletronuclear, Angra dos Reis, RJ (Brazil); Alonso, T.C.; Silva, T.V.; Oliveira, C.M. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Lima, F.F.; Oliveira, M.L.; Lacerda, I.V.B. [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Fajgelj, A. [International Atomic Energy Agency (IAEA), Vienna (Austria)

    2013-08-15

    In 2011, in Brazil, a National Intercalibration and Intercomparison exercise on in vivo measurement of iodine-131 in the thyroid was carried out in the scope of the Project IAEABRA9055 'Establishing a National Laboratory Network for Internal Individual Monitoring'. The exercise was conducted by the Institute for Radiation Protection and Dosimetry (IRD) and the Institute for Nuclear and Energetic Research (IPEN), from National Nuclear Energy Commission (CNEN). The objectives of the exercise were to (i) update information on current instrumentation resources available in the in vivo monitoring laboratories in operation in Brazil and to (ii) verify the reliability of the results of measurements of iodine-131 in thyroid provided by those laboratories. The procedure consisted on the measurement of a neck-thyroid anthropomorphic phantom provided by the In Vivo Monitoring Laboratory of IRD, containing two barium-133 standard sources certified by the National Laboratory for Metrology of Ionizing Radiation. Each participant should measure the phantom in a period of five days. The five laboratories are located in the States of Rio de Janeiro, Sao Paulo, Minas Gerais and Pernambuco, in the following Institutions: Institute for Radiation Protection and Dosimetry, Nuclear Power Station Almirante Alvaro Alberto, Center for the Development of Nuclear Technology, Institute for Nuclear and Energetic Research, and Regional Center for Nuclear Sciences. The results reported included: activity measured, minimum detectable activity, accuracy and precision. The performance of the laboratories was evaluated according to the criteria suggested by ANSI 13.30 indicating their capacity to provide reliable results of iodine-131 content in the thyroid. (author)

  18. Accurate mass replacement method for the sediment concentration measurement with a constant volume container

    Science.gov (United States)

    Ban, Yunyun; Chen, Tianqin; Yan, Jun; Lei, Tingwu

    2017-04-01

    The measurement of sediment concentration in water is of great importance in soil erosion research and soil and water loss monitoring systems. The traditional weighing method has long been the foundation of all the other measuring methods and instrument calibration. The development of a new method to replace the traditional oven-drying method is of interest in research and practice for the quick and efficient measurement of sediment concentration, especially field measurements. A new method is advanced in this study for accurately measuring the sediment concentration based on the accurate measurement of the mass of the sediment-water mixture in the confined constant volume container (CVC). A sediment-laden water sample is put into the CVC to determine its mass before the CVC is filled with water and weighed again for the total mass of the water and sediments in the container. The known volume of the CVC, the mass of sediment-laden water, and sediment particle density are used to calculate the mass of water, which is replaced by sediments, therefore sediment concentration of the sample is calculated. The influence of water temperature was corrected by measuring water density to determine the temperature of water before measurements were conducted. The CVC was used to eliminate the surface tension effect so as to obtain the accurate volume of water and sediment mixture. Experimental results showed that the method was capable of measuring the sediment concentration from 0.5 up to 1200 kg m-3. A good liner relationship existed between the designed and measured sediment concentrations with all the coefficients of determination greater than 0.999 and the averaged relative error less than 0.2%. All of these seem to indicate that the new method is capable of measuring a full range of sediment concentration above 0.5 kg m-3 to replace the traditional oven-drying method as a standard method for evaluating and calibrating other methods.

  19. Visceral adipose tissue area measurement at a single level: can it represent visceral adipose tissue volume?

    Science.gov (United States)

    Noumura, Yusuke; Kamishima, Tamotsu; Sutherland, Kenneth; Nishimura, Hideho

    2017-08-01

    Measurement of visceral adipose tissue (VAT) needs to be accurate and sensitive to change for risk monitoring. The purpose of this study is to determine the CT slice location where VAT area can best reflect changes in VAT volume and body weight. 60 plain abdominal CT images from 30 males [mean age (range) 51 (41-68) years, mean body weight (range) 71.1 (101.9-50.9) kg] who underwent workplace screenings twice within a 1-year interval were evaluated. Automatically calculated and manually corrected areas of the VAT of various scan levels using "freeform curve" region of interest on CT were recorded and compared with body weight changes. The strongest correlations of VAT area with VAT volume and body weight changes were shown in a slice 3 cm above the lower margin of L3 with r values of 0.853 and 0.902, respectively. VAT area measurement at a single level 3 cm above the lower margin of the L3 vertebra is feasible and can reflect changes in VAT volume and body weight. Advances in knowledge: As VAT area at a CT slice 3cm above the lower margin of L3 can best reflect interval changes in VAT volume and body weight, VAT area measurement should be selected at this location.

  20. Ectopic goitrous submandibular thyroid with goitrous orthotopic thyroid gland

    OpenAIRE

    Bhardwaj, Avinash Kumar; Mani, Vinayaga; Dixit, Rashmi; Garg, Anju

    2016-01-01

    Ectopic thyroid is a rare developmental anomaly with lingual thyroid accounting for majority of the cases. The presence of ectopic thyroid tissue lateral to the midline is very rare, and very few cases located in the submandibular region have been reported. The simultaneous finding of submandibular ectopic thyroid tissue and a functional orthotopic thyroid gland is even rarer. In the differential diagnosis of an ectopic submandibular thyroid, it is fundamental to exclude a metastasis from wel...

  1. Fine needle aspiration of the thyroid

    Science.gov (United States)

    ... is Performed This is a test to diagnose thyroid disease or thyroid cancer . It is often used to ... What Abnormal Results Mean Abnormal results may mean: Thyroid disease such as goiter or thyroiditis Noncancerous tumors Thyroid ...

  2. Measurement of lung lobar volume of children with funnel chest by computed tomography

    International Nuclear Information System (INIS)

    Watanabe, Toshiaki; Watanabe, Atsushi

    2004-01-01

    The aim of this study was to evaluate the influence of funnel chest on lung lobar volume and the correlation of lung lobar volume to the severity of funnel chest, which was measured by using computed tomographic (CT) images. Fifty-one patients with funnel chest (group 1) and 28 children without funnel chest (group 2) were selected for this study. The CT scans were obtained from the apex to the base of the lung at inspiratory phase. The outlines of the lung lobes were traced, and the area of the lung lobes in a cross-sectional plane was calculated. The lobar volume was determined by the thickness of scan space multiplied by the total area of all slices in each lobe. There was no difference between total lung capacity of group 1 and group 2. The left lower lobar volumes of group 1 was significantly smaller than group 2 (362±269 ml vs 539±361 ml). Both the ratios of the left lower lobar and left lung volume to the whole lung volume were significantly smaller group 1 than in group 2 (19.39±2.88% vs 24.01±1.98%, 42.87±2.99% vs 45.91±1.58%, respectively). On the other hand, ratios of the right lower lobar, left upper lobar and right lung volume to the whole lung volume were larger in group 1 (27.71±3.32% vs 25.97±2.03%, 23.47±2.20% vs 21.90±1.44%, 57.14±2.99% vs 54.09±1.58%, respectively). There were correlations between the pectus index (p=0.0109, r=-0.354) and the ratio of the left lower lobar volume to the whole lung volume to the depression rate (p=0.0174, r=-0.332) and between the pectus index (p=0.0053, |r|=0.385) and the ratio of each lung to the depression rate (p=0.0004, |r|=0.476). A new index, the ratio of the left to the right side of the heart, indicating the grade of heart displacement to the left was created and adapted for the study. The left-right ratio of the heart was significantly larger in group 1 than in group 2 (82.0±4.7 vs 67.8±3.0), and there were correlations of the left-right ratio of the heart to the ratio of the right upper

  3. Added value of thyroglobulin measurement in the fine-needle aspiration washout to diagnose cervical metastatic lymphadenopathy from papillary thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Lan; Lee, Tae Hyun; Park, Dong Hee [Dept. of Diagnostic Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-11-15

    The aim of this study was to evaluate added value and diagnostic threshold value of thyroglobulin measurement in the fine-needle aspiration washout for detecting cervical lymph node metastasis from papillary thyroid cancer on pre and postoperative patients. Total 219 cervical lymph nodes from 180 patients with papillary thyroid cancer were evaluated for fine needle aspiration cytology and thyroglobulin in fine needle aspiration (FNA-Tg), using immunometric chemiluminescent assay. Eighty-six patients were preoperative and remaining 94 patients were on follow up after total thyroidectomy. Final diagnoses were made on pathology of dissected lymph nodes or follow-up examination for at least 12 months. One hundred and twelve metastatic lymph nodes were finally confirmed in 94 patients out of total 180 patients. Sensitivity of FNA-Tg was 99.1, 98.21, 97.20%, respectively with threshold level at 1, 10, serum Tgng/mL, which were higher sensitivity of fine needle aspiration. Combined FNA and FNA-Tg with threshold at 1, 10, 100 ng/mL raised sensitivity and specificity to 100%, respectively. All 6 lymph nodes that were false negative on FNA were correctly diagnosed as metastasis on FNA-Tg with threshold of 1, 10, 100, and serum thyroglobulin. FNA-Tg with threshold level at 100 ng/mL combined FNA showed highest sensitivity (100%) and specificity (97.56%) on preoperative patient groups among the 1, 10, 100, serum Tg threshold value. But, FNA only showed adequately high sensitivity (100%) and specificity (96.96%) on postoperative patient groups. Using receiver operating characteristic curve (ROC) curve analysis, cut off value was 57.69 in total patient, 78.66 in preoperative patient, and 32.81 in postoperative patient. FNA-Tg combined with FNA showed excellent sensitivity and specificity. FNA-Tg showed very high sensitivity and specificity at threshold level 78.66 ng/mL in preoperative patients, but FNA-Tg had less benefit on the postoperative patient group, having high

  4. 3omega method to measure thermal properties of electrically conducting small-volume liquid.

    Science.gov (United States)

    Choi, Sun Rock; Kim, Joonwon; Kim, Dongsik

    2007-08-01

    This work presents a method to measure the thermal conductivity and heat capacity of electrically conducting small-volume liquid samples using the 3omega technique. A mathematical model of heat transfer is derived to determine the thermal properties from the 3omega signal considering the device geometry. In order to validate the model, an experimental apparatus has been designed and set up to measure the thermal properties (thermal conductivity and heat capacity) of seven different liquid samples. The results show good agreement with other literature values, demonstrating that the suggested method is effective for measuring the thermal properties of electrically conducting liquids. More importantly, the result with a sample volume of 1 microl demonstrates the resolution of the thermal conductivity as precise as 0.01% which corresponds to a thermal-conductivity change of 10(-4) Wm K in the case of water-based solutions.

  5. Serum thyroglobulin: tumor marker in thyroid carcinoma

    International Nuclear Information System (INIS)

    Ajay Kumar; Shah, D.H.

    1999-01-01

    Measurement of s-Tg is of limited value in the diagnosis of primary thyroid tumor but is very useful in post-operative management of differentiated thyroid carcinoma. The sensitivity and the specificity of Tg determination is comparable to that obtained with whole body scan WBS, however, both are complimentary. In our experience, the accuracy of s-Tg determination whether on or off thyroxin medication does not differ significantly

  6. Quantitative measurement of regional lung gas volume by synchrotron radiation computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Monfraix, Sylvie [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble (France); Bayat, Sam [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble (France); Porra, Liisa [Department of Physical Sciences, University of Helsinki, POB 64, FIN-00014 Helsinki (Finland); Berruyer, Gilles [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble (France); Nemoz, Christian [European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble (France); Thomlinson, William [Canadian Light Source, 101 Perimeter Road, Saskatoon, SK S7N 0X4 (Canada); Suortti, Pekka [Department of Physical Sciences, University of Helsinki, POB 64, FIN-00014 Helsinki (Finland); Sovijaervi, Anssi R A [Department of Clinical Physiology and Nuclear Medicine, Helsinki University Central Hospital, POB 340, FIN-00029 HUS, Helsinki (Finland)

    2005-01-07

    The aim of this study was to assess the feasibility of a novel respiration-gated spiral synchrotron radiation computed tomography (SRCT) technique for direct quantification of absolute regional lung volumes, using stable xenon (Xe) gas as an inhaled indicator. Spiral SRCT with K-edge subtraction using two monochromatic x-ray beams was used to visualize and directly quantify inhaled Xe concentrations and airspace volumes in three-dimensional (3D) reconstructed lung images. Volume measurements were validated using a hollow Xe-filled phantom. Spiral images spanning 49 mm in lung height were acquired following 60 breaths of an 80% Xe-20% O{sub 2} gas mixture, in two anaesthetized and mechanically ventilated rabbits at baseline and after histamine aerosol inhalation. Volumetric images of 20 mm lung sections were obtained at functional residual capacity (FRC) and at end-inspiration. 3D images showed large patchy filling defects in peripheral airways and alveoli following histamine provocation. Local specific lung compliance was calculated based on FRC/end-inspiration images in normal lung. This study demonstrates spiral SRCT as a new technique for direct determination of regional lung volume, offering possibilities for non-invasive investigation of regional lung function and mechanics, with a uniquely high spatial resolution. An example of non-uniform volume distribution in rabbit lung following histamine inhalation is presented.

  7. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    R.R. Uchida

    2003-07-01

    Full Text Available Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t21 = 2.37, P = 0.028. In addition, there was a trend (P values between 0.05 and 0.10 to smaller volumes of the right temporal lobe (7%, t21 = 1.99, P = 0.06, right amygdala (8%, t21 = 1.83, P = 0.08, left amygdala (5%, t21 = 1.78, P = 0.09 and left hippocampus (9%, t21 = 1.93, P = 0.07 in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025, with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures.

  8. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Neurologia e Psicologia Medica]. E-mail: fgraeff@keynet.com.br; Santos, A.C. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Clinica Medica; Guimaraes, F.S. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Farmacologia

    2003-07-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t{sub 21} = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t{sub 21} = 1.99, P = 0.06), right amygdala (8%, t{sub 21} = 1.83, P = 0.08), left amygdala (5%, t{sub 21} = 1.78, P 0.09) and left hippocampus (9%, t{sub 21} = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  9. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G.; Santos, A.C.; Guimaraes, F.S.

    2003-01-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t 21 = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t 21 = 1.99, P = 0.06), right amygdala (8%, t 21 = 1.83, P = 0.08), left amygdala (5%, t 21 = 1.78, P 0.09) and left hippocampus (9%, t 21 = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  10. Environmental radioiodine in thyroids of grazing animals

    International Nuclear Information System (INIS)

    Van Middlesworth, L.

    1990-01-01

    Animal thyroids are excellent indicators of environmental contamination from radioiodine, a fact largely unappreciated before 1954. From continuous monitoring of excised thyroids in Nal well-detectors, we know that high-altitude releases of mixed fission products caused increases of 10 3 to 10 5 times the minimal detectable level of 131 I (3.7 mBq/g) in sheep thyroids from the United States, Europe, Asia, Australia, and New Zealand. Within 6 weeks after high-altitude releases, sheep thyroids from different continents of the same hemisphere contained comparable concentrations of 131 I: more than 10 4 times greater concentrations than cow's milk and 5 x 10 3 times greater concentrations than human thyroids from similar areas. In contrast, during the low-altitude Chernobyl release, average 131 I concentrations in animal thyroids, at distances greater than 1,200 km from Chernobyl, were distributed as the inverse square of the distance from the source. 129 I concentrations measured since 1984 with a germanium well-detector in thyroids of sheep slaughtered in Birmingham, England, ranged from 3 to 50 mBq/g organ weight. Similar quantities of 125 I were present intermittently in thyroids of sheep slaughtered in Birmingham since 1986. The source of the 125 I, which is not a fission product, is not clear. For comparison, deer thyroids from the Savannah River Reservation, USA, contained 10 to 7 x 10 5 mBq 129 I/g. Although this isotope is not a biological hazard, it is a long-lived tracer of fission products

  11. The reproduction accuracy for stereolithographic model of the thyroid gland derived from the visible human dataset.

    Science.gov (United States)

    Kapakin, Samet; Demiryurek, Deniz

    2009-07-01

    To investigate reproduction accuracy of the rapid prototyping technique by comparing 3-dimensional computer-aided design (CAD) (virtual) model with stereolithographic (solid) replica of the thyroid gland. The Visible Human Dataset was used as the input imaging data. The Surfdriver software package was applied on these images to reconstruct the thyroid gland as 3-dimensional Data Exchange File (DXF) models. These models were post-processed in Cinema 4D and 3D-Doctor software for Virtual Reality Modeling Language (VRML) and Standard Triangulation Language (STL) formats. Stereolithographic replica was manufactured in the rapid prototyping machine using STL format. This study was conducted between June 1-30, 2008 at the Department of Anatomy, Hacettepe University, Ankara, Turkey. An excellent agreement was found in comparing the maximal dimensions of the CAD model of the thyroid gland and the corresponding stereolithographic model. Visual and tactile examination of the thyroid gland model allowed correct depiction of the thyroid gland anatomy. The accuracy of the stereolithographic model was attained by comparing wih the CAD model. Dimensional analysis showed that an average difference between the measurements on the virtual and the solid model was 0.09 mm (p=0.06), ranging from 0.07-0.92 mm. Thyroid volume and surface area were calculated to be 25393.9 mm3 and 8242.8 mm2 using 3D-Doctor software, which were agreement with those obtained from Brunn's formula. Stereolithographic biomodeling is a state-of-the-art and reliable method of visualizing anatomoclinical structures and abnormalities.

  12. Ectopic goitrous submandibular thyroid with goitrous orthotopic thyroid gland

    Science.gov (United States)

    Bhardwaj, Avinash Kumar; Mani, Vinayaga; Dixit, Rashmi; Garg, Anju

    2016-01-01

    Ectopic thyroid is a rare developmental anomaly with lingual thyroid accounting for majority of the cases. The presence of ectopic thyroid tissue lateral to the midline is very rare, and very few cases located in the submandibular region have been reported. The simultaneous finding of submandibular ectopic thyroid tissue and a functional orthotopic thyroid gland is even rarer. In the differential diagnosis of an ectopic submandibular thyroid, it is fundamental to exclude a metastasis from well-differentiated thyroid cancer, even when primary thyroid carcinoma is not demonstrable. PMID:27413274

  13. Ectopic goitrous submandibular thyroid with goitrous orthotopic thyroid gland

    Directory of Open Access Journals (Sweden)

    Avinash Kumar Bhardwaj

    2016-01-01

    Full Text Available Ectopic thyroid is a rare developmental anomaly with lingual thyroid accounting for majority of the cases. The presence of ectopic thyroid tissue lateral to the midline is very rare, and very few cases located in the submandibular region have been reported. The simultaneous finding of submandibular ectopic thyroid tissue and a functional orthotopic thyroid gland is even rarer. In the differential diagnosis of an ectopic submandibular thyroid, it is fundamental to exclude a metastasis from well-differentiated thyroid cancer, even when primary thyroid carcinoma is not demonstrable.

  14. The thyroid gland and thyroid hormones in sheepshead minnow (Cyprinodon variegatus) during early development and metamorphosis.

    Science.gov (United States)

    Schnitzler, Joseph G; Klaren, Peter H M; Mariavelle, Emeline; Das, Krishna

    2016-04-01

    The sheepshead minnow is widely used in ecotoxicological studies that only recently have begun to focus on disruption of the thyroid axis by xenobiotics and endocrine disrupting compounds. However, reference levels of the thyroid prohormone thyroxine (T4) and biologically active hormone 3,5,3'-triiodothyronine (T3) and their developmental patterns are unknown. This study set out to describe the ontogeny and morphology of the thyroid gland in sheepshead minnow, and to correlate these with whole-body concentrations of thyroid hormones during early development and metamorphosis. Eggs were collected by natural spawning in our laboratory. T4 and T3 were extracted from embryos, larvae and juveniles and an enzyme-linked immunoassay was used to measure whole-body hormone levels. Length and body mass, hatching success, gross morphology, thyroid hormone levels and histology were measured. The onset of metamorphosis at 12-day post-hatching coincided with surges in whole-body T4 and T3 concentrations. Thyroid follicles were first observed in pre-metamorphic larvae at hatching and were detected exclusively in the subpharyngeal region, surrounding the ventral aorta. Follicle size and thyrocyte epithelial cell heights varied during development, indicating fluctuations in thyroid hormone synthesis activity. The increase in the whole-body T3/T4 ratio was indicative of an increase in outer ring deiodination activity. This study establishes a baseline for thyroid hormones in sheepshead minnows, which will be useful for the understanding of thyroid hormone functions and in future studies of thyroid toxicants in this species.

  15. Thyroid Autoantibodies in the Cerebrospinal Fluid of Subjects with and without Thyroid Disease: Implications for Hashimoto’s Encephalopathy

    Directory of Open Access Journals (Sweden)

    Ioannis Ilias

    2015-01-01

    Full Text Available Introduction. Plasma antithyroid peroxidase (anti-TPO and anti-thyroglobulin antibodies (anti-Tg are widely used in the diagnosis of autoimmune thyroiditis. No research has compared anti-TPO and anti-Tg both in plasma and cerebrospinal fluid (CSF of healthy individuals vis-à-vis patients with thyroid disease. Methods. We measured anti-TPO and anti-Tg antibodies in plasma and CSF in nine subjects (mean age ± SD: 73 ± 6 years with hypothyroidism and nine subjects (mean age ± SD: 73 ± 8 years without thyroid disease. Results. The concentration of anti-TPO autoantibodies in CSF was very low compared to plasma in both subjects with thyroid and without thyroid disease (P=0.007. CSF anti-Tg autoantibodies titers were very low compared to the plasma in subjects with thyroid disease (P=0.004, whereas, in subjects without thyroid disease, this difference did not reach statistical significance (P=0.063. Conclusions. Thyroid autoantibodies levels were low in plasma and CSF; we did not observe any transfer of thyroid autoantibodies from the peripheral blood to the CSF. Therefore, regarding Hashimoto’s encephalopathy, where elevated antithyroid autoantibodies are often measured in blood, it is more likely that thyroiditis and encephalopathy represent nonspecific, but distinct, events of an aggressive immune system.

  16. Evaluation of clinical hypothyroidism risk due to irradiation of thyroid and pituitary glands in radiotherapy of nasopharyngeal cancer patients

    International Nuclear Information System (INIS)

    Lin, Zhixiong; Wang, Xiaoyan; Xie, Wenjia; Che, Kaijun; Wu, Vincent W.C.

    2013-01-01

    Radiation-induced thyroid dysfunction after radiotherapy for nasopharyngeal cancer (NPC) has been reported. This study investigated the radiation effects of the thyroid and pituitary glands on thyroid function after radiotherapy for NPC. Sixty-five NPC patients treated with radiotherapy were recruited. Baseline thyroid hormone levels comprising free triiodothyronine (fT3), free thyroxine (fT4) and thyroid-stimulating hormone (TSH) were taken before treatment and at 3, 6, 12 and 18 months. A seven-beam intensity-modulated radiotherapy plan was generated for each patient. Thyroid and pituitary gland dose volume histograms were generated, dividing the patients into four groups: high (>50Gy) thyroid and pituitary doses (HTHP group); high thyroid and low pituitary doses (HTLP group); low thyroid and high pituitary doses; and low thyroid and pituitary doses. Incidence of hypothyroidism was analysed. Twenty-two (34%) and 17 patients (26%) received high mean thyroid and pituitary doses, respectively. At 18 months, 23.1% of patients manifested various types of hypothyroidism. The HTHP group showed the highest incidence (83.3%) of hypothyroidism, followed by the HTLP group (50%). NPC patients with high thyroid and pituitary gland doses carried the highest risk of abnormal thyroid physiology. The dose to the thyroid was more influential than the pituitary dose at 18 months after radiotherapy, and therefore more attention should be given to the thyroid gland in radiotherapy planning.

  17. A spheroidal control volume for the quantitative measurement of regurgitant flow by cardiac MRI.

    Science.gov (United States)

    Kortright, Eduardo; Rayarao, Geetha; Li, Longchuan; Anayiotos, Andreas S; Biederman, Robert W W; Doyle, Mark

    2008-01-01

    We sought to show that a spheroidally shaped control volume (CV), formed from a minimal MRI data set, can be used to measure regurgitant flow through a defective cardiac valve consistently and accurately under a variety of flow conditions. Using a pulsatile flow pump and phantoms simulating severe valvular regurgitation, we acquired 31 scans of two or three radially oriented slices, using a variety of flow waveforms and regurgitant volumes of 12 to 55 ml. Data sets included high- and low-resolution scans, and variable-rate sparse sampling was also applied to reduce the scan time. An oblate spheroid was placed in the pump chamber opposite the jet and fit as tightly as possible to isomagnitude velocity contours at 25% of the velocity encoding limit. Normalized regurgitant volumes (NRVs) expressed as a percentage of the pump setting were obtained from the product of the spheroid surface area with the velocities normal to it. Mean +/- SD NRV values were 96.8 +/- 6.6% for all scans. Imaging times in the breath-hold range were obtained using reduced resolution and variable-rate sparse sampling approaches without significant degradation in accuracy. In our preliminary findings, the spheroidal CV method showed clear potential for the development of a robust, clinically feasible technique for the measurement of regurgitant volume.

  18. A contact-free volumetric measurement of facial volume after third molar osteotomy: proof of concept.

    Science.gov (United States)

    Brüllmann, Dan; Jürchott, Lena Marie; John, Christoph; Trempler, Christina; Schwanecke, Ulrich; Schulze, Ralf K W

    2014-01-01

    The present study tested the reliability of an optical scanning device for the objective assessment of postoperative facial swelling. Twenty control subjects bearing a defined volume of water (10-30 mL) in an intraorally carried balloon were tested to assess the measurement accuracy of the device. As a proof of concept, facial volumes of 59 surgical cases were recorded before osteotomy and 1 and 7 days after intervention with the use of a structured light scanner. The median difference between the applied and the measured volumes was 0.67 mL for the control test with the artificial swelling simulated using water balloons. For subjects having third molar osteotomy, extraoral volume increased to 5.29 cm(3) 1 day after surgery (95% CI 5.22-8.52) and decreased to 0.00 mL (95% CI 0.85-2.55) after 7 days. Contact-free visible-light 3-dimensional scanning is reliable for the objective assessment of postoperative facial swelling. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Impact of the time window on plasma volume measurement with indocyanine green

    International Nuclear Information System (INIS)

    Jacob, M; Chappell, D; Conzen, P; Finsterer, U; Rehm, M; Krafft, A; Becker, B F

    2008-01-01

    Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements to estimate its practical impact (group 2). To monoexponentially extrapolate back to the specific extinction at the time of dye injection, two different time windows were applied to each decay curve, comparing the plasma volumes resulting from sampling within a short (≤5 min) versus a longer (>5 min) period of time. Extrapolating back from the longer period led to a higher apparent plasma volume relative to the shorter period in both groups, the difference being 348 ± 171 ml (group 1) and 384 ± 131 ml (group 2; mean ± SD; p < 0.05 each). This result was due to a reliable monoexponentiality of decay only up to the 5th min after dye injection. Thus, to estimate the initial distribution space of indocyanine green via monoexponential extrapolation, the first linear kinetic of indocyanine green decay should be taken

  20. Theoretical calibration of a NaI(Tl) detector for the measurement of {sup 131}I in a thyroid phantom; Calibracao teorica de um detetor NaI(Tl) para a determinacao de {sup 131}I em um simulador de tireoide

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Dept. de Metrologia das Radiacoes]. E-mail: lventur@net.ipen.br

    2002-07-01

    This paper describes the theoretical calibration of a NaI(Tl) detector using Monte Carlo Method, for the measurement of {sup 131} I in a thyroid phantom. The thyroid is represented by the region between two concentric cylinders, where the inner one represents the trachea and the outer one represents the neck. {sup 133} Ba was used for experimental calibration. The results shows that the calibration procedure is suitable for {sup 131} I measurements. (author)

  1. Determinants of Extraocular Muscle Volume in Patients with Graves' Disease

    Directory of Open Access Journals (Sweden)

    Samer El-Kaissi

    2012-01-01

    Full Text Available Background. To examine factors contributing to extraocular muscle (EOM volume enlargement in patients with Graves’ hyperthyroidism. Methods. EOM volumes were measured with orbital magnetic resonance imaging (MRI in 39 patients with recently diagnosed Graves’ disease, and compared to EOM volumes of 13 normal volunteers. Thyroid function tests, uptake on thyroid scintigraphy, anti-TSH-receptor antibody positivity and other parameters were then evaluated in patients with EOM enlargement. Results. 31/39 patients had one or more enlarged EOM, of whom only 2 patients had clinical EOM dysfunction. Compared to Graves’ disease patients with normal EOM volumes, those with EOM enlargement had significantly higher mean serum TSH (0.020±0.005 versus 0.007±0.002 mIU/L; P value 0.012, free-T4 (52.9±3.3 versus 41.2±1.7 pmol/L; P value 0.003 and technetium uptake on thyroid scintigraphy (13.51±1.7% versus 8.55±1.6%; P value 0.045. There were no differences between the 2 groups in anti-TSH-receptor antibody positivity, the proportion of males, tobacco smokers, or those with active ophthalmopathy. Conclusions. Patients with recently diagnosed Graves’ disease and EOM volume enlargement have higher serum TSH and more severe hyperthyroidism than patients with normal EOM volumes, with no difference in anti-TSH-receptor antibody positivity between the two groups.

  2. A comparative study of linear measurement of the brain and three-dimensional measurement of brain volume using CT scans

    International Nuclear Information System (INIS)

    Hamano, K.; Iwasaki, N.; Takeya, T.; Takita, H.

    1993-01-01

    Parameters of linear measurement were compared with actual brain volume to assess the significance of linear measurements as indices of atrophy in 31 neurologically normal children and 22 neurologically abnormal children. Brain volume was established by means of an image-analyzing system using contiguous CT scans. The parameters or indices estimated were: (1) the maximum transverse width of both hemispheres, (2) the maximum longitudinal length of both hemispheres, (3) the maximum frontal subarachnoid space, (4) the maximum width of the interhemispheric fissure, (5) the maximum width of the Sylvian fissure, (6) Evans' ratio, (7) the maximum width of the third ventricle, (8) the cella media index, (9) the maximum width of the fourth ventricle. In neurologically normal children, the maximum transverse width of both hemispheres, the maximum longitudinal length of both hemispheres, the maximum width of the interhemispheric fissure and the maximum width of the Sylvian fissure correlated significantly with the combined volume (CV) of both hemipheres and basal ganglia. In particular, the maximum transverse width of both hemispheres and the maximum longitudinal length of both hemispheres had a high correlation. In neurologically abnormal children the maximum transverse width of both hemispheres and the maximum width of the interhemispheric fissure were significantly correlated with the CV of both hemispheres and basal ganglia. (orig.)

  3. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  4. A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

    International Nuclear Information System (INIS)

    Liu, Yixun; Summers, Ronald M.; Yao, Jianhua; Liu, Songtao; Sibley, Christopher T.; Bluemke, David A.; Nacif, Marcelo S.

    2013-01-01

    Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use

  5. Single sweep three-dimensional carotid ultrasound: reproducibility in plaque and artery volume measurements.

    Science.gov (United States)

    Kalashyan, Hayrapet; Shuaib, Ashfaq; Gibson, Patrick H; Romanchuk, Helen; Saqqur, Maher; Khan, Khurshid; Osborne, Jonathon; Becher, Harald

    2014-02-01

    There is a need for non-invasive and accurate techniques for assessment of severity of atherosclerotic disease in the carotid arteries. Recently an automated single sweep three-dimensional ultrasound (3D US) technique became available. The aims of this study were to evaluate the feasibility and reproducibility of the automated single sweep method in a cohort of patients undergoing clinically indicated carotid ultrasound. Consecutive patients with a history of stroke or transient ischemic attack (TIA) and having a plaque in the internal carotid artery (ICA) were recruited for this study. Imaging was performed using a Philips iU 22 ultrasound system equipped with the single sweep volumetric transducer vL 13-5. Analysis was performed offline with software provided by the manufacturer. Two independent observers performed all measurements. Of 137 arteries studied (from 79 patients), plaque and artery volumes could be measured in 106 (77%). Reproducibility of plaque volume measurements was assessed in 82 arteries. Bland-Altman analysis demonstrated good inter-observer reproducibility with limits of agreement -0.06 to +0.07 ml. The mean percentage difference between two observers was 5.6% ± 6.0%. Reproducibility of artery volume measurement was assessed in 31 cases. Bland-Altman analysis demonstrated limits of agreement from -0.15 to +0.15 ml. The mean percentage difference was 6.4 ± 5.9%. The new automated single sweep 3D ultrasound is feasible in the majority of patients. Good reproducibility in plaque and artery volume measurements makes this technique suitable for serial assessment of carotid plaques. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  6. Fetal lung volume measurement by MRI with high-speed imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Osada, Hisao; Kaku, Kenshi [Chiba Univ. (Japan). Hospital

    2002-08-01

    Although ultrasonography is widely used for fetal morphologic observation, magnetic resonance imaging (MRI) has gained popularity as a new prenatal diagnostic method with recent introduction of high-speed imaging systems. Infants with lung hypoplasia affecting respiratory function require intensive management starting immediately after birth. Therefore, accurate prenatal differential diagnosis and severity evaluation are extremely important for these fetuses. The aim of this study is to measure fetal lung volume using a computer-based, three-dimensional MRI imaging system and to evaluate the possibility of clinical applications of this procedure. A total of 96 fetuses were evaluated, all were morphologically abnormal, and MRI was done for advanced assessment from 24 to 39 weeks gestation. Three-directional views of fetal chest were imaged by Signa Horizon, 1.5 Tesla, version 5.6 (General Electronics) with the following conditions; coil: TORSO coil, sequence: SSFSE (single shot fast spin echo), slice thickness: 5 mm, and imaging speed: 2 seconds/slice. To calculate the lung volume and create three-dimensional image, the lung area in each slice was traced out, then multiplied using computer image processing. Simultaneously, the volumes of all slices were summed to give the volume of each lung. Linear regression analysis and analysis of covariance (ANCOVA) were used for statistical analyses. In all cases, clear images were obtained, and were adequate for three-dimensional evaluation of the fetal lung. Thirty-five fetuses had poor outcomes, such as intrauterine fetal death, neonatal death, and intensive respiratory care. Regression lines of lung volume versus gestational week were calculated for these fetuses with poor outcome and 61 other fetuses with good outcome. ANCOVA, with gestational week as a covariant, revealed a significant intergroup difference in the lung volume (p<0.001). Similarly, regression lines of lung volume versus fetal body weight estimated by