WorldWideScience

Sample records for thyroid dose assessments

  1. Assessment of the individual thyroid dose for the cohort members of the Belarusian-American epidemiological study

    International Nuclear Information System (INIS)

    Minenko, Victor; Kuchta, Tatyana; Khrutchinsky, Arkady; Kutsen, Semion; Bouville, Andre; Drozdovitch, Vladimir; Luckyanov, Nickolas; Shinkarev, Sergey; Gavrilin, Yury; Khrouch, Valeri

    2008-01-01

    Full text: The U.S. National Cancer Institute and the Ministry of Health of Belarus conduct jointly an epidemiological study of thyroid cancer and other thyroid diseases in a cohort of 12,000 Belarusian subjects aged up to 18 years at the time of the Chernobyl accident in 1986. One of the important aspects of the study is the reconstruction of individual doses for all cohort members. Reconstruction of thyroid doses is based on the measurements of 131 I content in the thyroid glands of the subjects, which were performed in May-June 1986. In addition, the following information elicited by the personal interview is used to evaluate individual 131 I intake function for each cohort member: residential history; consumption rates of milk, dairy products and leafy vegetables and origin of consumed foodstuffs; and individual countermeasures undertaken shortly after the accident. The second round of thyroid doses estimation, which is currently conducted, includes Monte Carlo calculations of the age-dependent conversion coefficients from the measuring devices reading to the 131 I activity in the thyroid; estimation of the influence of surface contamination and internal body-burden on the exposure rate measured near the thyroid; and validation of parameters of the radioecological model used to assess the 131 I intake function. The revised thyroid dose estimates and their uncertainties will be presented, and the results obtained will be compared with the previous set of thyroid dose estimates. (author)

  2. The Assessment of I-131 Internal Doses of Nuclear Medicine Workers in Korea Using Thyroid uptake system

    International Nuclear Information System (INIS)

    Bahn, Young Kag; Oh, Gi Back; Lee, Chang Ho; Lee, Jong Doo; Yeom, Yu Sun; Hwang, Young Muk

    2012-01-01

    There are possibilities the radiation workers could intake the radiation when workers deal with radiation-materials. Therefore, internal radiation doses of radiation workers need to be assessed. Although an application of the nuclear medicine is continuously increased in Korea, there is not a proper tool and form to monitor the internal doses of nuclear medicine workers. However, it is possible to attain the internal doses of I-131 to evaluate using thyroid uptake and well count system. In this study, we measured and evaluated the I-131 internal doses of nuclear medicine workers in Korea using thyroid uptake and well count system and performed an air sampling

  3. Assessment of dose in thyroid and salivary glands in dental radiology using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Mantuano, Natalia de O.; Silva, Ademir X. da; Correa, Samanda C.A.

    2011-01-01

    Radiobiological and epidemiological studies have provided evidence of risk of salivary and thyroid glands tumors incidence associated with oral radiology. Based on these studies, the tissue weighting factors were reviewed by the International Commission on Radiological Protection (ICRP) in 2007. The main objective of the present work is to estimate the absorbed dose on thyroid and salivary glands (parotid, submandibular and sublingual), during a complete periapical examination. The complete periapical examination was simulated using a Spectro 70X Seletronic X-ray dental equipment on an Alderson Rando phantom with Harshaw LiF:Mg,Ti thermoluminescent dosemeters (TLD100). A PTW DIADOS dosimetric system was used for calibration. The TLD100 were inserted into the phantom slices corresponding to the organs of interest. During a complete periapical examination, the highest evaluated mean absorbed dose was 4.9 mGy in the right submandibular gland and the lowest one of 1.5 mGy in the left thyroid lobe. Entrance surface doses ranged from 2.1 to 2.6 mGy, measured, respectively, for the techniques of upper left molar and lower right molar. When compared with the diagnostic reference levels (DRL), the entrance surface doses values were lower than the DRLs recommended in Brazilian current legislation. However, the dosimetric results show the need of optimization for complete periapical examination to minimize patient exposure. Measurements were performed without the use of thyroid protectors. The use of this device is certainly an easy and simple method of dose reduction. (author)

  4. Assessment of dose in thyroid and salivary glands in dental radiology using thermoluminescent dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Mantuano, Natalia de O.; Silva, Ademir X. da [Instituto Alberto Luiz Coimbra de Pos-Graduacao e Pesquisa em Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Canevaro, Luca V.; Mauricio, Claudia Lucia P. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ) Rio de Janeiro, RJ (Brazil); Correa, Samanda C.A., E-mail: scorrea@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Radiobiological and epidemiological studies have provided evidence of risk of salivary and thyroid glands tumors incidence associated with oral radiology. Based on these studies, the tissue weighting factors were reviewed by the International Commission on Radiological Protection (ICRP) in 2007. The main objective of the present work is to estimate the absorbed dose on thyroid and salivary glands (parotid, submandibular and sublingual), during a complete periapical examination. The complete periapical examination was simulated using a Spectro 70X Seletronic X-ray dental equipment on an Alderson Rando phantom with Harshaw LiF:Mg,Ti thermoluminescent dosemeters (TLD100). A PTW DIADOS dosimetric system was used for calibration. The TLD100 were inserted into the phantom slices corresponding to the organs of interest. During a complete periapical examination, the highest evaluated mean absorbed dose was 4.9 mGy in the right submandibular gland and the lowest one of 1.5 mGy in the left thyroid lobe. Entrance surface doses ranged from 2.1 to 2.6 mGy, measured, respectively, for the techniques of upper left molar and lower right molar. When compared with the diagnostic reference levels (DRL), the entrance surface doses values were lower than the DRLs recommended in Brazilian current legislation. However, the dosimetric results show the need of optimization for complete periapical examination to minimize patient exposure. Measurements were performed without the use of thyroid protectors. The use of this device is certainly an easy and simple method of dose reduction. (author)

  5. The reconstruction of thyroid dose following Chernobyl

    International Nuclear Information System (INIS)

    Stepanenko, V.; Kondrashov, A.; Yaskova, E.; Petin, D.; Skvortsov, V.; Parshkov, E.; Gavrilin, Yu.; Khrousch, V.; Shinkarev, S.; Makarenkova, I.; Volkov, V.; Zvonova, I.; Bratilova, A.; Kaidanovsky, J.; Minenko, V.; Drozdovich, V.; Ulanovsky, A.; Korneev, S.; Heinemann, K.; Pomplun, E.; Hille, R.; Bailiff, A.

    1996-01-01

    The report presents the overview of several approaches in working out the methods of thyroid internal dose reconstruction following Chernobyl. One of these approaches was developed (IBPh, Moscow; MRRC, Obninsk; IRM, Minsk) using the correlations between the mean dose calculation based on I 131 thyroid content measurements and Cs 137 contamination of territories. The available data on I 131 soil contamination were taken into account. The lack of data on I 131 soil contamination was supposed to be compensated by I 129 measurements in soil samples from contaminated territories. The semiempiric model was developed for dose reconstruction. The comparison of the results obtained by semiempiric model and empirical values are presented. The estimated values of average dose according semiempiric model were used for individual dose reconstruction. The IRH (St.-Petersburg) has developed the following method for individual dose reconstruction: correlation between the total I 131 radioiodine incorporation in thyroid and whole body Cs 137 content during first months after accident. The individual dose reconstruction is also mentioned to be performed using the data on individual milk consumption during first weeks after accident. For evaluation of average doses it is suggested to use the linear correlation: thyroid dose values based on radioiodine thyroid measurements vs Cs 137 contamination, air kerma rate, mean I 131 concentration in the milk. The method for retrospective reconstruction of thyroid dose caused by short-living iodine nuclides released after the Chernobyl accident has been developed by Research Centre, Juelich, Germany. It is based on the constant ratio that these nuclides have with the long-living I 129 . The contamination of soil samples by this nuclide can be used to assess thyroid doses. First results of I 129 contamination values and derived thyroid doses are to be presented

  6. Assessment of absorbed dose to thyroid, parotid and ovaries in patients undergoing Gamma Knife radiosurgery

    International Nuclear Information System (INIS)

    Hasanzadeh, H; Sharafi, A; Verdi, M Allah; Nikoofar, A

    2006-01-01

    Stereotactic radiosurgery was originally introduced by Lars Leksell in 1951. This treatment refers to the noninvasive destruction of an intracranial target localized stereotactically. The purpose of this study was to identify the dose delivered to the parotid, ovaries, testis and thyroid glands during the Gamma Knife radiosurgery procedure. A three-dimensional, anthropomorphic phantom was developed using natural human bone, paraffin and sodium chloride as the equivalent tissue. The phantom consisted of a thorax, head and neck and hip. In the natural places of the thyroid, parotid (bilateral sides) and ovaries (midline), some cavities were made to place TLDs. Three TLDs were inserted in a batch with 1 cm space between the TLDs and each batch was inserted into a single cavity. The final depth of TLDs was 3 cm from the surface for parotid and thyroid and was 15 cm for the ovaries. Similar batches were placed superficially on the phantom. The phantom was gamma irradiated using a Leksell model C Gamma Knife unit. Subsequently, the same batches were placed superficially over the thyroid, parotid, testis and ovaries in 30 patients (15 men and 15 women) who were undergoing radiosurgery treatment for brain tumours. The mean dosage for treating these patients was 14.48 ± 3.06 Gy (10.5-24 Gy) to a mean tumour volume of 12.30 ± 9.66 cc (0.27-42.4 cc) in the 50% isodose curve. There was no significant difference between the superficial and deep batches in the phantom studies (P-value < 0.05). The mean delivered doses to the parotid, thyroid, ovaries and testis in human subjects were 21.6 ± 15.1 cGy, 9.15 ± 3.89 cGy, 0.47 ± 0.3 cGy and 0.53 ± 0.31 cGy, respectively. The data can be used in making decisions for special clinical situations such as treating pregnant patients or young patients with benign lesions who need radiosurgery for eradication of brain tumours

  7. Thyroid Radiation Dose and Other Risk Factors of Thyroid Carcinoma Following Childhood Cancer.

    Science.gov (United States)

    de Vathaire, Florent; Haddy, Nadia; Allodji, Rodrigue S; Hawkins, Mike; Guibout, Catherine; El-Fayech, Chiraz; Teinturier, Cécile; Oberlin, Odile; Pacquement, Hélène; Diop, Fara; Kalhouche, Amar; Benadjaoud, Mohamedamine; Winter, David; Jackson, Angela; Bezin Mai-Quynh, Giao; Benabdennebi, Aymen; Llanas, Damien; Veres, Cristina; Munzer, Martine; Nguyen, Tan Dat; Bondiau, Pierre-Yves; Berchery, Delphine; Laprie, Anne; Deutsch, Eric; Lefkopoulos, Dimitri; Schlumberger, Martin; Diallo, Ibrahima; Rubino, Carole

    2015-11-01

    Thyroid carcinoma is a frequent complication of childhood cancer radiotherapy. The dose response to thyroid radiation dose is now well established, but the potential modifier effect of other factors requires additional investigation. This study aimed to investigate the role of potential modifiers of the dose response. We followed a cohort of 4338 5-year survivors of solid childhood cancer treated before 1986 over an average of 27 years. The dose received by the thyroid gland and some other anatomical sites during radiotherapy was estimated after reconstruction of the actual conditions in which irradiation was delivered. Fifty-five patients developed thyroid carcinoma. The risk of thyroid carcinoma increased with a radiation dose to the thyroid of up to two tenths of Gy, then leveled off for higher doses. When taking into account the thyroid radiation dose, a surgical or radiological splenectomy (>20 Gy to the spleen) increased thyroid cancer risk (relative risk [RR] = 2.3; 95% confidence interval [CI], 1.3-4.0), high radiation doses (>5 Gy) to pituitary gland lowered this risk (RR = 0.2; 95% CI, 0.1-0.6). Patients who received nitrosourea chemotherapy had a 6.6-fold (95% CI, 2.5-15.7) higher risk than those who did not. The excess RR per Gy of radiation to the thyroid was 4.7 (95% CI, 1.7-22.6). It was 7.6 (95% CI, 1.6-33.3) if body mass index at time of interview was equal or higher than 25 kg/m(2), and 4.1 (95% CI, 0.9-17.7) if not (P for interaction = .1). Predicting thyroid cancer risk following childhood cancer radiation therapy probably requires the assessment of more than just the radiation dose to the thyroid. Chemotherapy, splenectomy, radiation dose to pituitary gland, and obesity also play a role.

  8. Dermatologic radiotherapy and thyroid cancer. Dose measurements and risk quantification

    International Nuclear Information System (INIS)

    Goldschmidt, H.; Gorson, R.O.; Lassen, M.

    1983-01-01

    Thyroid doses for various dermatologic radiation techniques were measured with thermoluminescent dosimeters and ionization rate meters in an Alderson-Rando anthropomorphic phantom. The effects of changes in radiation quality and of the use or nonuse of treatment cones and thyroid shields were evaluated in detail. The results indicate that the potential risk of radiogenic thyroid cancer is very small when proper radiation protection measures are used. The probability of radiogenic thyroid cancer developing and the potential mortality risk were assessed quantitatively for each measurement. The quantification of radiation risks allows comparisons with risks of other therapeutic modalities and the common hazards of daily life

  9. Results of large scale thyroid dose reconstruction in Ukraine

    International Nuclear Information System (INIS)

    Likhtarev, I.; Sobolev, B.; Kairo, I.; Tabachny, L.; Jacob, P.; Proehl, G.; Goulko, G.

    1996-01-01

    In 1993, the Ukrainian Ministry on Chernobyl Affairs initiated a large scale reconstruction of thyroid exposures to radioiodine after the Chernobyl accident. The objective was to provide the state policy on social compensations with a scientific background. About 7000 settlements from five contaminated regions have gotten certificates of thyroid exposure since then. Certificates contain estimates of the average thyroid dose from 131 I for seven age groups. The primary dose estimates used about 150000 direct measurements of the 131 I activity in the thyroid glands of inhabitants from Chernigiv, Kiev, Zhytomyr, and also Vinnytsa regions. Parameters of the assumed intake function were related to environmental and questionnaire data. The dose reconstruction for the remaining territory was based on empirical relations between intake function parameters and the 137 Cs deposition. The relationship was specified by the distance and the direction to the Chernobyl Nuclear Power Plant. The relations were first derived for territories with direct measurements and then they were spread on other areas using daily iodine releases and atmospheric transportation routes. The results of the dose reconstruction allowed to mark zones on the territory of Ukraine according to the average levels of thyroid exposures. These zones underlay a policy of post-accidental health care and social compensations. Another important application of the thyroid dose reconstruction is the radiation risk assessment of thyroid cancer among people exposed during childhood due to the Chernobyl accident

  10. Efficacy of different I-131 doses for thyroid remnant ablation

    International Nuclear Information System (INIS)

    Nguyen, X.C.; Thiep, T.V.; Hung, N.C.

    2007-01-01

    Full text: Radioactive iodine 131 I has been widely used as a treatment modality of differentiated thyroid carcinoma. The need for high dose radioiodine ablation of thyroid remnant is still in question. The aim of this prospective study was to assess the efficacy of 131 I different single and fractionated doses in ablation of post-operative thyroid remnant. Patients and methods: One hundred-twelve patients were included in this study. Sixty-one patients with TSH≥30 μU/ml were treated 30 mCi in group 1 (36 patients) or 100 mCi in group 2 (25 patients). Fifty one patients with TSH 131 I high dose of 100 mCi and no severe adverse effect in the other groups. Conclusion: Single high dose (100 mCi) may be more efficient than single low dose (30 mCi) for post-operative remnant ablation with serum TSH≥30 μU/ml and the efficacy of low fractionated doses (30+30 mCi) was comparable with high-fractionated dose (30+100 mCi) for post-operative remnant ablation with low serum TSH in differentiated thyroid carcinoma. (author)

  11. Validation of 131I ecological transfer models and thyroid dose assessments using Chernobyl fallout data from the Plavsk district, Russia

    Science.gov (United States)

    Zvonova, I.; Krajewski, P.; Berkovsky, V.; Ammann, M.; Duffa, C.; Filistovic, V.; Homma, T.; Kanyar, B.; Nedveckaite, T.; Simon, S.L.; Vlasov, O.; Webbe-Wood, D.

    2009-01-01

    Within the project “Environmental Modelling for Radiation Safety” (EMRAS) organized by the IAEA in 2003 experimental data of 131I measurements following the Chernobyl accident in the Plavsk district of Tula region, Russia were used to validate the calculations of some radioecological transfer models. Nine models participated in the inter-comparison. Levels of 137Cs soil contamination in all the settlements and 131I/137Cs isotopic ratios in the depositions in some locations were used as the main input information. 370 measurements of 131I content in thyroid of townspeople and villagers, and 90 measurements of 131I concentration in milk were used for validation of the model predictions. A remarkable improvement in models performance comparing with previous inter-comparison exercise was demonstrated. Predictions of the various models were within a factor of three relative to the observations, discrepancies between the estimates of average doses to thyroid produced by most participant not exceeded a factor of ten. PMID:19783331

  12. Radiation dose reduction at a price: the effectiveness of a thyroid shield during head CT scanning

    International Nuclear Information System (INIS)

    Fu Qiang; Lu Tao; Zhang Ling

    2008-01-01

    Objective: To assess radiation dose to the thyroid in patients undergoing head CT scanning and to evaluate dose reduction to the thyroid by load shielding. Methods: A post-morterm was scanned by different model and study was undertaken to evaluate the dose reduction by thyroid lead shields and assess their practicality in a clinical setting. (a)No thyroid shields and (b) thyroid shield. One thermoluminescent dosimeters (TLDs)were placed over the thyroid gland center, A thyroid lead shield (Pb eq 0.5mm)was placed around the neck of post-morterm. Scan parameter, CTDIw and DLP were recorded. Results: (a) 0.207mSv; (b) 0.085mSv. A mean effective radiation dose reduction of 58% was seen in the shielded versus the unshielded. Conclusion: Thyroid exposure to scattered radiation from head CT scanning only once is associated with a low but not negligible risk of cancer, but accumulatived doses to the thyroid are serious, highlighting the need for increased awareness of patient radiation protection. Thyroid lead shielding yields significant radiation protection, which should be used routinely during head CT scan. (authors)

  13. Occupational thyroid dose during cardiovascular examinations

    International Nuclear Information System (INIS)

    Kawaharada, Yasuhiro; Kayama, Jiro; Hatori, Noboru; Takahashi, Noboru; Koyama, Ichiro; Shiraishi, Akihisa; Otake, Hidenori; Miyazawa, Yasushi

    1991-01-01

    Medical system has been recently divided into many divisions where appropriate examinations and treatments are performed by specialists in each field. Special and complicated radiologic examinations such as cardiovascular angiography are performed by specialists. An occupational exposure dose tends to increase and to be limited to some specialized physicians and technicians. Therefore, efficient protective equipment and clothing have to be seriously considered so as to decrease the occupational exposure dose. The thyroid gland is not protected by any of the conventional protectors. We have tried to decrease the occupational exposure doses by improving the conventional protector and utilizing various other materials. The paper is a report on the effectiveness of the methods used and the results. (author)

  14. Thyroid absorbed dose using TLDs during mammography

    International Nuclear Information System (INIS)

    Gonzalez A, M.; Melendez L, M.; Davila M, P.

    2015-10-01

    Full text: In this study, the mean glandular dose (MGD) and the thyroid dose (D Thy) were measured in 200 women screened with mammography in Cranio caudal (Cc) and mediolateral oblique projections. All mammograms were performed with Giotto-Ims (6000-14-M2 Model) equipment, which was verified to meet the criteria of quality of NOM-229-Ssa-2002. During audits performance and HVL, for each anode filter combinations was measured with the camera Radcal mammography equipment 10 X 6-6M (HVL = 0.26 mm Al). D Thy measurements were performed with TLD dosimeters (LiF:Mn) , that were read with the Harshaw 3500 TLD reader. The MGD, was obtained according to the UK and European protocols for mammographic dosimetry using a plane parallel chamber (Standard Imaging, Model A-600) calibrated by a radiation beam UW-23-Mo (= 0.279 mm Al HVL). A comparative statistical analysis was carried out with the measured MGD and D thy. The thyroid mean dose was 0.063 mGy and 0.078 mGy for Cc and mediolateral oblique respectively. There is a linear correlation between the MGD and the D Thy slightly influenced by the anode-filter combination. Using a 95% for the confidence interval in MGD (1.07 mGy), the 90% of measurements are in agreement with the established uncertainty limits. The D Thy are lower than the MGD. There is no risk for cancer induction in thyroid in women due to mammography screening. (Author)

  15. Measurement of {sup 131}I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital

    Energy Technology Data Exchange (ETDEWEB)

    Brudecki, K.; Mietelski, J.W. [Polish Academy of Sciences, Institute of Nuclear Physics, Krakow (Poland); Kowalska, A.; Szczodry, A. [Holy Cross Cancer Center, Department of Endocrinology and Nuclear Medicine, Kielce (Poland); Zagrodzki, P. [Polish Academy of Sciences, Institute of Nuclear Physics, Krakow (Poland); Jagiellonian University, Department of Food Chemistry and Nutrition, Medical College, Krakow (Poland); Mroz, T. [Pedagogical University in Cracow, Krakow (Poland); Janowski, P. [AGH University of Science and Technology, Krakow (Poland)

    2017-03-15

    This paper presents results of {sup 131}I thyroid activity measurements in 30 members of the nuclear medicine personnel of the Department of Endocrinology and Nuclear Medicine Holy Cross Cancer Centre in Kielce, Poland. A whole-body spectrometer equipped with two semiconductor gamma radiation detectors served as the basic research instrument. In ten out of 30 examined staff members, the determined {sup 131}I activity was found to be above the detection limit (DL = 5 Bq of {sup 131}I in the thyroid). The measured activities ranged from (5 ± 2) Bq to (217 ± 56) Bq. The highest activities in thyroids were detected for technical and cleaning personnel, whereas the lowest values were recorded for medical doctors. Having measured the activities, an attempt has been made to estimate the corresponding annual effective doses, which were found to range from 0.02 to 0.8 mSv. The highest annual equivalent doses have been found for thyroid, ranging from 0.4 to 15.4 mSv, detected for a cleaner and a technician, respectively. The maximum estimated effective dose corresponds to 32% of the annual background dose in Poland, and to circa 4% of the annual limit for the effective dose due to occupational exposure of 20 mSv per year, which is in compliance with the value recommended by the International Commission on Radiological Protection. (orig.)

  16. Measurement of 131I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital

    International Nuclear Information System (INIS)

    Brudecki, K.; Mietelski, J.W.; Kowalska, A.; Szczodry, A.; Zagrodzki, P.; Mroz, T.; Janowski, P.

    2017-01-01

    This paper presents results of 131 I thyroid activity measurements in 30 members of the nuclear medicine personnel of the Department of Endocrinology and Nuclear Medicine Holy Cross Cancer Centre in Kielce, Poland. A whole-body spectrometer equipped with two semiconductor gamma radiation detectors served as the basic research instrument. In ten out of 30 examined staff members, the determined 131 I activity was found to be above the detection limit (DL = 5 Bq of 131 I in the thyroid). The measured activities ranged from (5 ± 2) Bq to (217 ± 56) Bq. The highest activities in thyroids were detected for technical and cleaning personnel, whereas the lowest values were recorded for medical doctors. Having measured the activities, an attempt has been made to estimate the corresponding annual effective doses, which were found to range from 0.02 to 0.8 mSv. The highest annual equivalent doses have been found for thyroid, ranging from 0.4 to 15.4 mSv, detected for a cleaner and a technician, respectively. The maximum estimated effective dose corresponds to 32% of the annual background dose in Poland, and to circa 4% of the annual limit for the effective dose due to occupational exposure of 20 mSv per year, which is in compliance with the value recommended by the International Commission on Radiological Protection. (orig.)

  17. Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956)- An Assessment of Quantities released, Off-Site Radiation Doses, and Potential Excess Risks of Thyroid Cancer, Volume 1

    International Nuclear Information System (INIS)

    Apostoaei, A.I.; Burns, R.E.; Hoffman, F.O.; Ijaz, T.; Lewis, C.J.; Nair, S.K.; Widner, T.E.

    1999-01-01

    In the early 1990s, concern about the Oak Ridge Reservation's past releases of contaminants to the environment prompted Tennessee's public health officials to pursue an in-depth study of potential off-site health effects at Oak Ridge. This study, the Oak Ridge dose reconstruction, was supported by an agreement between the U.S. Department of Energy (DOE) and the State of Tennessee, and was overseen by a 12-member panel appointed by Tennessee's Commissioner of Health. One of the major contaminants studied in the dose reconstruction was radioactive iodine, which was released to the air by X-10 (now called Oak Ridge National Laboratory) as it processed spent nuclear reactor fuel from 1944 through 1956. The process recovered radioactive lanthanum for use in weapons development. Iodine concentrates in the thyroid gland so health concerns include various diseases of the thyroid, such as thyroid cancer. The large report, ''Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956) - An Assessment of Quantities Released, Off-site Radiation Doses, and Potential Excess Risks of Thyroid Cancer,'' is in two volumes. Volume 1 is the main body of the report, and Volume 1A, which has the same title, consists of 22 supporting appendices. Together, these reports serve the following purposes: (1) describe the methodologies used to estimate the amount of iodine-131 (I-131) released; (2) evaluate I-131's pathway from air to vegetation to food to humans; (3) estimate doses received by human thyroids; (4) estimate excess risk of acquiring a thyroid cancer during ones lifetime; and (5) provide equations, examples of historical documents used, and tables of calculated values. Results indicate that females born in 1952 who consumed milk from a goat pastured a few miles east of X-10 received the highest doses from I-131 and would have had the highest risks of contracting thyroid cancer. Doses from cow's milk are considerably less . Detailed

  18. Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956)- An Assessment of Quantities released, Off-Site Radiation Doses, and Potential Excess Risks of Thyroid Cancer, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Apostoaei, A.I.; Burns, R.E.; Hoffman, F.O.; Ijaz, T.; Lewis, C.J.; Nair, S.K.; Widner, T.E.

    1999-07-01

    In the early 1990s, concern about the Oak Ridge Reservation's past releases of contaminants to the environment prompted Tennessee's public health officials to pursue an in-depth study of potential off-site health effects at Oak Ridge. This study, the Oak Ridge dose reconstruction, was supported by an agreement between the U.S. Department of Energy (DOE) and the State of Tennessee, and was overseen by a 12-member panel appointed by Tennessee's Commissioner of Health. One of the major contaminants studied in the dose reconstruction was radioactive iodine, which was released to the air by X-10 (now called Oak Ridge National Laboratory) as it processed spent nuclear reactor fuel from 1944 through 1956. The process recovered radioactive lanthanum for use in weapons development. Iodine concentrates in the thyroid gland so health concerns include various diseases of the thyroid, such as thyroid cancer. The large report, ''Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956) - An Assessment of Quantities Released, Off-site Radiation Doses, and Potential Excess Risks of Thyroid Cancer,'' is in two volumes. Volume 1 is the main body of the report, and Volume 1A, which has the same title, consists of 22 supporting appendices. Together, these reports serve the following purposes: (1) describe the methodologies used to estimate the amount of iodine-131 (I-131) released; (2) evaluate I-131's pathway from air to vegetation to food to humans; (3) estimate doses received by human thyroids; (4) estimate excess risk of acquiring a thyroid cancer during ones lifetime; and (5) provide equations, examples of historical documents used, and tables of calculated values. Results indicate that females born in 1952 who consumed milk from a goat pastured a few miles east of X-10 received the highest doses from I-131 and would have had the highest risks of contracting thyroid cancer. Doses from cow

  19. Irradiation doses on thyroid gland during the postoperative irradiation for breast cancer.

    Science.gov (United States)

    Akın, Mustafa; Ergen, Arzu; Unal, Aysegul; Bese, Nuran

    2014-01-01

    Thyroid gland is one of the radiosensitive endocrine organs in the body. It has been shown that direct irradiation of thyroid with total doses of 26 to 30 Gy can lead to functional abnormalities. In this study, irradiation doses on thyroid gland of the patients who received postoperative chest-wall/breast and regional nodal irradiation were assessed. Retrospective analyses of treatment plans from 122 breast cancer patients who were treated with 3D conformal radiotherapy (3D CRT) planning was performed. All patients received irradiation to supraclavicular/level III lymph nodes in addition to chest-wall/breast. A total dose of 46 Gy was delivered in 25 days to supraclavicular/level III lymph node region while a total dose of 50 Gy was delivered to whole breast/chest-wall. Thyroid gland was contoured on 2-5 mm thickness of computed tomography scans. Absolute thyroid volume, mean thyroid doses were calculated. The mean thyroid volume of all patients was 16.7 cc (min: 1.9 cc, max: 41.6 cc). The mean irradiation dose on was 22.5 Gy (0.32 Gy-46.5 Gy). The level of dose was higher than 26 Gy in 44% of the patients. In majority of the node-positive breast cancer patients treated with 3D CRT, the thyroid gland was exposed to considerable doses. On the other hand, for 44% of the patients are at risk for developing thyroid function abnormalities which should be considered during the routine follow-up.

  20. Thyroid Cancer Risk Assessment Tool

    Science.gov (United States)

    The R package thyroid implements a risk prediction model developed by NCI researchers to calculate the absolute risk of developing a second primary thyroid cancer (SPTC) in individuals who were diagnosed with a cancer during their childhood.

  1. Absorbed dose by thyroid in case of nuclear accidents

    International Nuclear Information System (INIS)

    Campos, Laelia; Attie, Marcia Regina Pereira; Amaral, Ademir

    2011-01-01

    Radioisotopes of iodine are produced in abundance in nuclear fission reactions, and great amounts of radioiodine may be released into the environment in case of a nuclear reactor accident. Thyroid gland is among the most radiosensitive organs due to its capacity to concentrate iodine. The aim of this work was to evaluate the importance of contributions of internally deposited iodines ( 131 I, 132 I, 133 I, 134 I and 135 I) to the dose absorbed to thyroid follicle and to the whole organ, after internal contamination by those isotopes. For internal dose calculation, the code of particles transport MCNP4C was employed. The results showed that, in case of nuclear accidents, the contribution of short-lived iodines for total dose is about 45% for thyroid of newborn and about 40% for thyroid of adult. Thus, these contributions should not be neglected in a prospective evaluation of risks associated to internal contamination by radioactive iodine. (author)

  2. Thyroid doses for evacuees from the Fukushima nuclear accident

    Science.gov (United States)

    Tokonami, Shinji; Hosoda, Masahiro; Akiba, Suminori; Sorimachi, Atsuyuki; Kashiwakura, Ikuo; Balonov, Mikhail

    2012-07-01

    A primary health concern among residents and evacuees in affected areas immediately after a nuclear accident is the internal exposure of the thyroid to radioiodine, particularly I-131, and subsequent thyroid cancer risk. In Japan, the natural disasters of the earthquake and tsunami in March 2011 destroyed an important function of the Fukushima Daiichi Nuclear Power Plant (F1-NPP) and a large amount of radioactive material was released to the environment. Here we report for the first time extensive measurements of the exposure to I-131 revealing I-131 activity in the thyroid of 46 out of the 62 residents and evacuees measured. The median thyroid equivalent dose was estimated to be 4.2 mSv and 3.5 mSv for children and adults, respectively, much smaller than the mean thyroid dose in the Chernobyl accident (490 mSv in evacuees). Maximum thyroid doses for children and adults were 23 mSv and 33 mSv, respectively.

  3. X-ray and radioiodine dose to thyroid follicular cells

    International Nuclear Information System (INIS)

    Faw, R.E.

    1991-01-01

    Radiation doses to the epithelial cells of thyroid follicles have been calculated for internal exposure by radionuclides of iodine and by secondary radiations created as a result of interactions of externally administered x rays with iodine naturally occurring in the thyroid. Calculations were performed for the thyroids of subjects ranging from the newborn to the adult male. Results for internal radionuclides are reported as the dose rate to follicular-cell nuclei per unit specific activity of the radionuclide in the thyroid as a whole, i.e., as the specific ''S value'' as used in the MIRD method for internal dosimetry. Results for x rays are reported as the response function, i.e., the absorbed dose per unit fluence of primary x rays. Dose rates are subdivided into internal and external components, the former from radiations emitted within the colloid volume of any one follicle, and the latter from radiations emitted throughout the thyroid in follicles surrounding that one follicle. 37 refs., 5 figs., 3 tabs

  4. Thyroid neoplasia following low-dose radiation in childhood

    International Nuclear Information System (INIS)

    Ron, E.; Modan, B.; Preston, D.; Alfandary, E.; Stovall, M.; Boice, J.D. Jr.

    1989-01-01

    The thyroid gland is highly sensitive to the carcinogenic effects of ionizing radiation. Previously, we reported a significant increase of thyroid cancer and adenomas among 10,834 persons in Israel who received radiotherapy to the scalp for ringworm. These findings have now been extended with further follow-up and revised dosimetry. Overall, 98 thyroid tumors were identified among the exposed and 57 among 10,834 nonexposed matched population and 5392 sibling comparison subjects. An estimated thyroid dose of 9 cGy was linked to a fourfold (95% Cl = 2.3-7.9) increase of malignant tumors and a twofold (95% Cl = 1.3-3.0) increase of benign tumors. The dose-response relationship was consistent with linearity. Age was an important modifier of risk with those exposed under 5 years being significantly more prone to develop thyroid tumors than older children. The pattern of radiation risk over time could be described on the basis of a constant multiplication of the background rate, and an absolute risk model was not compatible with the observed data. Overall, the excess relative risk per cGy for thyroid cancer development after childhood exposure is estimated as 0.3, and the absolute excess risk as 13 per 10(6) PY-cGy. For benign tumors the estimated excess relative risk was 0.1 per cGy and the absolute risk was 15 per 10(6) PY-cGy

  5. Low-Dose Radioactive Iodine Destroys Thyroid Tissue Left after Surgery

    Science.gov (United States)

    A low dose of radioactive iodine given after surgery for thyroid cancer destroyed (ablated) residual thyroid tissue as effectively as a higher dose, with fewer side effects and less exposure to radiation, according to two randomized controlled trials.

  6. Dose-specific transcriptional responses in thyroid tissue in mice after 131I administration

    International Nuclear Information System (INIS)

    Rudqvist, Nils; Schüler, Emil; Parris, Toshima Z.; Langen, Britta; Helou, Khalil; Forssell-Aronsson, Eva

    2015-01-01

    Introduction: In the present investigation, microarray analysis was used to monitor transcriptional activity in thyroids in mice 24 h after 131 I exposure. The aims of this study were to 1) assess the transcriptional patterns associated with 131 I exposure in normal mouse thyroid tissue and 2) propose biomarkers for 131 I exposure of the thyroid. Methods: Adult BALB/c nude mice were i.v. injected with 13, 130 or 260 kBq of 131 I and killed 24 h after injection (absorbed dose to thyroid: 0.85, 8.5, or 17 Gy). Mock-treated mice were used as controls. Total RNA was extracted from thyroids and processed using the Illumina platform. Results: In total, 497, 546, and 90 transcripts were regulated (fold change ≥ 1.5) in the thyroid after 0.85, 8.5, and 17 Gy, respectively. These were involved in several biological functions, e.g. oxygen access, inflammation and immune response, and apoptosis/anti-apoptosis. Approximately 50% of the involved transcripts at each absorbed dose level were dose-specific, and 18 transcripts were commonly detected at all absorbed dose levels. The Agpat9, Plau, Prf1, and S100a8 gene expression displayed a monotone decrease in regulation with absorbed dose, and further studies need to be performed to evaluate if they may be useful as dose-related biomarkers for 131I exposure. Conclusion: Distinct and substantial differences in gene expression and affected biological functions were detected at the different absorbed dose levels. The transcriptional profiles were specific for the different absorbed dose levels. We propose that the Agpat9, Plau, Prf1, and S100a8 genes might be novel potential absorbed dose-related biomarkers to 131 I exposure of thyroid. Advances in knowledge: During the recent years, genomic techniques have been developed; however, they have not been fully utilized in nuclear medicine and radiation biology. We have used RNA microarrays to investigate genome-wide transcriptional regulations in thyroid tissue in mice after low

  7. Low dose iodine-131 therapy in solitary toxic thyroid nodules

    International Nuclear Information System (INIS)

    Prakash, Rajeev

    1999-01-01

    Forty patients with solitary hyperfunctioning thyroid nodules were treated with relatively low dose radioiodine therapy, 131 I doses were calculated taking into account thyroid mass and radioiodine kinetics to deliver 100 μCi/g of estimated nodule weight corrected for uptake. Patients remaining persistently hyperthyroid at four months after the initial therapy were retreated with a similarly calculated dose. Cure of the hyperthyroid state was achieved in all patients, total administered dose in individual cases ranging from 3-17 mCi. 28 of the 40 patients required a single therapy dose. 36 patients were euthyroid after a 4.5 year mean follow-up period. Four cases developed post therapy hypothyroidism requiring replacement therapy. Nodules regressed completely in nine cases following 131 I treatment, with partial regression in size in 19 patients. Control of hyperthyroid state in cases of solitary toxic thyroid nodules can be satisfactorily achieved using relatively low dose radioiodine therapy with low incidence of post therapy hypothyroidism. (author)

  8. Effect of action of fractioned ionizing radiation in small dose on thyroid gland of rats

    OpenAIRE

    О. О. Prykhodko; V. V. Lizogubov; V. S. Usenko

    2005-01-01

    The effect of fractionated X-irradiation by 0.25 Gy dose to rat thyroid gland was studied . It was shown the decrease of thyrocyte proliferative activity that can induce the late effect of pathogenesis to thyroid land and biochemical pathways that control by thyroid hormones. Additional effect by any mutagenic factor may induce thyroid tumor development.

  9. Fetus dose estimation in thyroid cancer post-surgical radioiodine therapy

    International Nuclear Information System (INIS)

    Mianji, Fereidoun A.; Karimi Diba, Jila; Babakhani, Asad

    2015-01-01

    Unrecognised pregnancy during radioisotope therapy of thyroid cancer results in hardly definable embryo/fetus exposures, particularly when the thyroid gland is already removed. Sources of such difficulty include uncertainty in data like pregnancy commencing time, amount and distribution of metastasized thyroid cells in body, effect of the thyroidectomy on the fetus dose coefficient etc. Despite all these uncertainties, estimation of the order of the fetus dose in most cases is enough for medical and legal decision-making purposes. A model for adapting the dose coefficients recommended by the well-known methods to the problem of fetus dose assessment in athyrotic patients is proposed. The model defines a correction factor for the problem and ensures that the fetus dose in athyrotic pregnant patients is less than the normal patients. A case of pregnant patient undergone post-surgical therapy by I-131 is then studied for quantitative comparison of the methods. The results draw a range for the fetus dose in athyrotic patients using the derived factor. This reduces the concerns on under- or over-estimation of the embryo/fetus dose and is helpful for personal and/or legal decision-making on abortion. (authors)

  10. Radiation absorbed dose to the human fetal thyroid

    International Nuclear Information System (INIS)

    Watson, E.E.

    1992-01-01

    The embryo/fetus is recognized to be particularly susceptible to damage from exposure to radiation. Many advisory groups have studied available information concerning radiation doses and radiation effects with the goal of reducing the risk to the embryo/fetus. Of particular interest are radioactive isotopes of iodine. Radioiodine taken into the body of a pregnant woman presents a possible hazard for the embryo/fetus. The fetal thyroid begins to concentrate iodine at about 13 weeks after conception and continues to do so throughout gestation. At term, the organic iodine concentration in the fetal blood is about 75% of that in the mother's blood. This paper presents a review the models that have been proposed for the calculation of the dose to the fetal thyroid from radioisotopes of iodine taken into the body of the pregnant woman as sodium iodide. A somewhat different model has been proposed, and estimates of the radiation dose to the fetal thyroid calculated from this model are given for each month of pregnancy from 123 I , 124 I , 125 I , and 131 I

  11. Proposal for dose measurement in the crystalline lens and thyroid in computerized tomography of paranasal sinuses

    International Nuclear Information System (INIS)

    Mello, Ana Caroline; Machado Neto, Vicente

    2014-01-01

    With the evolution of diagnostic imaging equipment, a computerized tomography (CT) has become one of the most used tests to assess pathologies affecting the paranasal sinuses. This work aims at presenting a method of obtaining measurements of dose in the eye lenses and thyroid, from the execution of CT of the paranasal sinuses protocol. Experimental procedure will be used in an object simulator (phantom) head and neck made with accessible materials and thermoluminescent dosimeters (TLDs) of LiF: Mg,Ti for the absorbed dose in the regions of interest, when exposed to radiation in a CT scanner 16 channels. After the dosimetric evaluation with phantom use, this methodology will be applied in vivo, or in patients with medical request for the examination and approval by the Ethics Committee. Thus, at the end of this survey protocols and actions aimed at reducing the absorbed dose in the eye lenses and thyroid without impairing the diagnostic image quality can be proposed. (author)

  12. Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

    Science.gov (United States)

    Chang, Lienard A; Miller, Donald L; Lee, Choonsik; Melo, Dunstana R; Villoing, Daphnée; Drozdovitch, Vladimir; Thierry-Chef, Isabelle; Winters, Sarah J; Labrake, Michael; Myers, Charles F; Lim, Hyeyeun; Kitahara, Cari M; Linet, Martha S; Simon, Steven L

    2017-12-01

    This study summarizes and compares estimates of radiation absorbed dose to the thyroid gland for typical patients who underwent diagnostic radiology examinations in the years from 1930 to 2010. The authors estimated the thyroid dose for common examinations, including radiography, mammography, dental radiography, fluoroscopy, nuclear medicine, and computed tomography (CT). For the most part, a clear downward trend in thyroid dose over time for each procedure was observed. Historically, the highest thyroid doses came from the nuclear medicine thyroid scans in the 1960s (630 mGy), full-mouth series dental radiography (390 mGy) in the early years of the use of x rays in dentistry (1930s), and the barium swallow (esophagram) fluoroscopic exam also in the 1930s (140 mGy). Thyroid uptake nuclear medicine examinations and pancreatic scans also gave relatively high doses to the thyroid (64 mGy and 21 mGy, respectively, in the 1960s). In the 21st century, the highest thyroid doses still result from nuclear medicine thyroid scans (130 mGy), but high thyroid doses are also associated with chest/abdomen/pelvis CT scans (18 and 19 mGy for males and females, respectively). Thyroid doses from CT scans did not exhibit the same downward trend as observed for other examinations. The largest thyroid doses from conventional radiography came from cervical spine and skull examinations. Thyroid doses from mammography (which began in the 1960s) were generally a fraction of 1 mGy. The highest average doses to the thyroid from mammography were about 0.42 mGy, with modestly larger doses associated with imaging of breasts with large compressed thicknesses. Thyroid doses from dental radiographic procedures have decreased markedly throughout the decades, from an average of 390 mGy for a full-mouth series in the 1930s to an average of 0.31 mGy today. Upper GI series fluoroscopy examinations resulted in up to two orders of magnitude lower thyroid doses than the barium swallow. There are

  13. Computation of thyroid doses and carcinogenic radiation risks to patients undergoing neck CT examinations

    International Nuclear Information System (INIS)

    Huda, W.; Spampinato, M. V.; Tipnis, S. V.; Magill, D.

    2013-01-01

    The aim of the study was to investigate how differences in patient anatomy and CT technical factors in neck CT impact on thyroid doses and the corresponding carcinogenic risks. The CTDI vol and dose-length product used in 11 consecutive neck CT studies, as well as data on automatic exposure control (AEC) tube current variation(s) from the image DICOM header, were recorded. For each CT image that included the thyroid, the mass equivalent water cylinder was estimated based on the patient cross-sectional area and average relative attenuation coefficient (Hounsfield unit, HU). Patient thyroid doses were estimated by accounting for radiation intensity at the location of the patient's thyroid, patient size and the scan length. Thyroid doses were used to estimate thyroid cancer risks as a function of patient demographics using risk factors in BEIR VII. The length of the thyroid glands ranged from 21 to 54 mm with an average length of 42±12 mm. Water cylinder diameters corresponding to the central slice through the patient thyroid ranged from 18 to 32 cm with a mean of 25±5 cm. The average CTDI vol (32-cm phantom) used to perform these scans was 26±6 mGy, but the use of an AEC increased the tube current by an average of 44 % at the thyroid mid-point. Thyroid doses ranged from 29 to 80 mGy, with an average of 55±19 mGy. A 20-y-old female receiving the highest thyroid dose of 80 mGy would have a thyroid cancer risk of nearly 0.1 %, but radiation risks decreased very rapidly with increasing patient age. The key factors that affect thyroid doses in neck CT examinations are the radiation intensity at the thyroid location and the size of the patient. The corresponding patient thyroid cancer risk is markedly influenced by patient sex and age. (authors)

  14. Dental radiography technique and equipment: How they influence the radiation dose received at the level of the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Rush, E.R. [School of Health Sciences, University of Ulster, Shore Road, Newtownabbey, Belfast BT37 0QB (United Kingdom)]. E-mail: emmaroserush@hotmail.com; Thompson, N.A. [School of Health Sciences, University of Ulster, Shore Road, Newtownabbey, Belfast BT37 0QB (United Kingdom)

    2007-08-15

    Purpose: The aim of this study was to investigate the influence that collimator and technique choice had on the radiation dose detected at the thyroid gland position, during intra-oral examinations of the upper and lower teeth. Radiation dose reduction from a different perspective, other than the application of lead-rubber shielding, was addressed. Methods: A study was performed at a regional dental school with the use of a phantom head/neck and a radiation dosemeter, to measure the radiation dose detected at the thyroid gland position. The radiation dose was assessed for two intra-oral techniques (paralleling and bisecting angle), and two collimators (rectangular and circular). The radiation dose was also assessed with and without the application of a thyroid shield. Standard descriptive statistics, followed by inferential statistics were applied to the data. Results: There was a significant reduction in the radiation dose detected at the thyroid gland position, when employing the paralleling technique (66.7%) and rectangular collimator (45.5%). Other factors, for example the tooth/teeth under examination, were also found to influence the radiation dose detected. Conclusion: Radiation dose reductions using the paralleling technique and rectangular collimator were outlined. The use of this low dose combination within dental practices remains limited, therefore, continued awareness and acceptance of radiation hazards need to be addressed.

  15. Dental radiography technique and equipment: How they influence the radiation dose received at the level of the thyroid gland

    International Nuclear Information System (INIS)

    Rush, E.R.; Thompson, N.A.

    2007-01-01

    Purpose: The aim of this study was to investigate the influence that collimator and technique choice had on the radiation dose detected at the thyroid gland position, during intra-oral examinations of the upper and lower teeth. Radiation dose reduction from a different perspective, other than the application of lead-rubber shielding, was addressed. Methods: A study was performed at a regional dental school with the use of a phantom head/neck and a radiation dosemeter, to measure the radiation dose detected at the thyroid gland position. The radiation dose was assessed for two intra-oral techniques (paralleling and bisecting angle), and two collimators (rectangular and circular). The radiation dose was also assessed with and without the application of a thyroid shield. Standard descriptive statistics, followed by inferential statistics were applied to the data. Results: There was a significant reduction in the radiation dose detected at the thyroid gland position, when employing the paralleling technique (66.7%) and rectangular collimator (45.5%). Other factors, for example the tooth/teeth under examination, were also found to influence the radiation dose detected. Conclusion: Radiation dose reductions using the paralleling technique and rectangular collimator were outlined. The use of this low dose combination within dental practices remains limited, therefore, continued awareness and acceptance of radiation hazards need to be addressed

  16. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  17. I-131 Dose Response for Incident Thyroid Cancers in Ukraine Related to the Chornobyl Accident

    OpenAIRE

    Brenner, Alina V.; Tronko, Mykola D.; Hatch, Maureen; Bogdanova, Tetyana I.; Oliynik, Valery A.; Lubin, Jay H.; Zablotska, Lydia B.; Tereschenko, Valery P.; McConnell, Robert J.; Zamotaeva, Galina A.; O?Kane, Patrick; Bouville, Andre C.; Chaykovskaya, Ludmila V.; Greenebaum, Ellen; Paster, Ihor P.

    2011-01-01

    Background: Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case?control studies, and studies of prevalent cancers. Objective: To address this limitation, we evaluated the dose?response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. Methods: The cohort consists of individuals < 18 years of age on 26 April 1986 who ...

  18. Iodine-129 Dose in LLW Disposal Facility Performance Assessments

    International Nuclear Information System (INIS)

    Wilhite, E.L.

    1999-01-01

    Iodine-129 has the lowest Performance Assessment derived inventory limit in SRS disposal facilities. Because iodine is concentrated in the body to one organ, the thyroid, it has been thought that dilution with stable iodine would reduce the dose effects of 129I.Examination of the dose model used to establish the Dose conversion factor for 129I shows that, at the levels considered in performance assessments of low-level waste disposal facilities, the calculated 129I dose already accounts for ingestion of stable iodine. At higher than normal iodine ingestion rates, the uptake of iodine by the thyroid itself decrease, which effectively cancels out the isotopic dilution effect

  19. Thyroiditis

    Science.gov (United States)

    ... Hypothyroidism in Children and Adolescents Pediatric Differentiated Thyroid Cancer Thyroid Nodules in Children and Adolescents Thyroiditis Resources Thyroiditis Brochure PDF Thyroiditis FAQs PDF En Español Tiroiditis El folleto de Tiroiditis Tiroiditis, Preguntas Frecuentes (FAQ) Search ...

  20. Dose distribution in lungs and thyroid from scatter photons of x-ray mammography imaging

    International Nuclear Information System (INIS)

    Faghihi, R.; Mehdizadeh, S.

    2006-01-01

    The contribution of scatter photons in dose of mammography image in thyroid and lungs are studied. Thyroid and in the form of distribution function and total delivered dose studied by direct measurement with Thermoluminescence dosimeter. The results of measurements compared to other published measurements and the total dose compared to our modelling with Monte Carlo method.. Our phantoms for direct measurement of Dose are a compressed breast phantom placed on a female RANDO phantom. The results of modelling and measurement are in agreement for the total delivered dose to thyroid and lungs and comparable to doses reported by the other researcher

  1. Recalculation of thyroid doses after the Chernobyl accident in a iodine deficient area

    International Nuclear Information System (INIS)

    Olko, P.; Niewiadomski, T.; Budzanowski, M.; Szybinski, Z.

    1996-01-01

    The thyroid doses were estimated in Poland shortly after the Chernobyl accident with assumption of stable iodine consumption for the reference man and areas with ''standard'' stable iodine consumption. These estimates are not representative for southern part of Poland which is known as the iodine deficient area. Therefore the thyroid doses were recalculated based on the real and differentiated stable iodine intakes for people groups of different age without and with thyroid blockade after the accident. (author). 11 refs, 10 figs, 3 tabs

  2. Recalculation of thyroid doses after the Chernobyl accident in a iodine deficient area

    Energy Technology Data Exchange (ETDEWEB)

    Olko, P; Niewiadomski, T; Budzanowski, M [Institute of Nuclear Physics, Cracow (Poland); Szybinski, Z [Jagiellonian Univ., Cracow (Poland). Dept. of Endocrinology

    1996-08-01

    The thyroid doses were estimated in Poland shortly after the Chernobyl accident with assumption of stable iodine consumption for the reference man and areas with ``standard`` stable iodine consumption. These estimates are not representative for southern part of Poland which is known as the iodine deficient area. Therefore the thyroid doses were recalculated based on the real and differentiated stable iodine intakes for people groups of different age without and with thyroid blockade after the accident. (author). 11 refs, 10 figs, 3 tabs.

  3. Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956)- An Assessment of Quantities released, Off-Site Radiation Doses, and Potential Excess Risks of Thyroid Cancer- APPENDICES Appendices-Volume 1A

    International Nuclear Information System (INIS)

    Apostoaei, A.I.; Burns, R.E.; Hoffman, F.O.; Ijaz, T.; Lewis, C.J.; Nair, S.K.; Widner, T.E.

    1999-01-01

    This report consists of all the appendices for the report described below: In the early 1990s, concern about the Oak Ridge Reservation's past releases of contaminants to the environment prompted Tennessee's public health officials to pursue an in-depth study of potential off-site health effects at Oak Ridge. This study, the Oak Ridge dose reconstruction, was supported by an agreement between the U.S. Department of Energy (DOE) and the State of Tennessee, and was overseen by a 12-member panel appointed by Tennessee's Commissioner of Health. One of the major contaminants studied in the dose reconstruction was radioactive iodine, which was released to the air by X-10 (now called Oak Ridge National Laboratory) as it processed spent nuclear reactor fuel from 1944 through 1956. The process recovered radioactive lanthanum for use in weapons development. Iodine concentrates in the thyroid gland so health concerns include various diseases of the thyroid, such as thyroid cancer. The large report, ''Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956) - An Assessment of Quantities Released, Off-site Radiation Doses, and Potential Excess Risks of Thyroid Cancer,'' is in two volumes. Volume 1 is the main body of the report, and Volume 1A, which has the same title, consists of 22 supporting appendices. Together, these reports serve the following purposes: (1) describe the methodologies used to estimate the amount of iodine-131 (I-131) released; (2) evaluate I-131's pathway from air to vegetation to food to humans; (3) estimate doses received by human thyroids; (4) estimate excess risk of acquiring a thyroid cancer during ones lifetime; and (5) provide equations, examples of historical documents used, and tables of calculated values as appendices. Results indicate that females born in 1952 who consumed milk from a goat pastured a few miles east of X-10 received the highest doses from I-131 and would have had the highest

  4. Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956)- An Assessment of Quantities released, Off-Site Radiation Doses, and Potential Excess Risks of Thyroid Cancer- APPENDICES Appendices-Volume 1A

    Energy Technology Data Exchange (ETDEWEB)

    Apostoaei, A.I.; Burns, R.E.; Hoffman, F.O.; Ijaz, T.; Lewis, C.J.; Nair, S.K.; Widner, T.E.

    1999-07-01

    This report consists of all the appendices for the report described below: In the early 1990s, concern about the Oak Ridge Reservation's past releases of contaminants to the environment prompted Tennessee's public health officials to pursue an in-depth study of potential off-site health effects at Oak Ridge. This study, the Oak Ridge dose reconstruction, was supported by an agreement between the U.S. Department of Energy (DOE) and the State of Tennessee, and was overseen by a 12-member panel appointed by Tennessee's Commissioner of Health. One of the major contaminants studied in the dose reconstruction was radioactive iodine, which was released to the air by X-10 (now called Oak Ridge National Laboratory) as it processed spent nuclear reactor fuel from 1944 through 1956. The process recovered radioactive lanthanum for use in weapons development. Iodine concentrates in the thyroid gland so health concerns include various diseases of the thyroid, such as thyroid cancer. The large report, ''Iodine-131 Releases from Radioactive Lanthanum Processing at the X-10 Site in Oak Ridge, Tennessee (1944-1956) - An Assessment of Quantities Released, Off-site Radiation Doses, and Potential Excess Risks of Thyroid Cancer,'' is in two volumes. Volume 1 is the main body of the report, and Volume 1A, which has the same title, consists of 22 supporting appendices. Together, these reports serve the following purposes: (1) describe the methodologies used to estimate the amount of iodine-131 (I-131) released; (2) evaluate I-131's pathway from air to vegetation to food to humans; (3) estimate doses received by human thyroids; (4) estimate excess risk of acquiring a thyroid cancer during ones lifetime; and (5) provide equations, examples of historical documents used, and tables of calculated values as appendices. Results indicate that females born in 1952 who consumed milk from a goat pastured a few miles east of X-10 received the highest doses from

  5. Scattered dose to thyroid from prophylactic cranial irradiation during childhood: a Monte Carlo study

    International Nuclear Information System (INIS)

    Mazonakis, Michalis; Tzedakis, Antonis; Damilakis, John; Varveris, Haris; Kachris, Stefanos; Gourtsoyiannis, Nicholas

    2006-01-01

    The purpose of this study was to estimate the scattered dose to thyroid from prophylactic cranial irradiation during childhood. The MCNP transport code and mathematical phantoms representing the average individual at ages 3, 5, 10, 15 and 18 years old were employed to simulate cranial radiotherapy using two lateral opposed fields. The mean radiation dose received by the thyroid gland was calculated. A 10 cm thick lead block placed on the patient's couch to shield the thyroid was simulated by MCNP code. The Monte Carlo model was validated by measuring the scattered dose to the unshielded and shielded thyroid using three different humanoid phantoms and thermoluminescense dosimetry. For a cranial dose of 18 Gy, the thyroid dose obtained by Monte Carlo calculations varied from 47 to 79 cGy depending upon the age of the child. Appropriate placement of the couch block resulted in a thyroid dose reduction by 39 to 54%. Thyroid dose values at all possible positions of the radiosensitive gland with respect to the inferior field edge at five different patient ages were found. The mean difference between Monte Carlo results and thyroid dose measurements was 9.6%. (note)

  6. Thyroid nodule prevalence and radiation dose from fallout near the Semipalatinsk test site in Kazakhstan

    International Nuclear Information System (INIS)

    Land, C.E.; Luckyanov, N.K.; Simon, S.L.; Zhumadilov, Z.; Gusev, B.I.; Hartshorne, M.N.; Carr, Z.A.

    2003-01-01

    Thyroid nodule prevalence was use as a biomarker for radiation-related thyroid cancer risk associated with dose from internal and external radiation sources in fallout from the Semipalatinsk Test Site (STS) in Kazakhstan. Ultrasound scans were done on the thyroid glands of 1990 current residents of 7 villages near the STS, all members of a defined study cohort established in the 1960s, and all juveniles at some time during 1949-1962. Questionnaire-guided interviews focused on residential history and childhood consumption of milk and milk products. A refined dose reconstruction algorithm, developed jointly by experts from Russia and the US, was applied to the resulting data to calculate individual estimates of thyroid dose from external and internal sources of fallout-related radiation. Individual radiation dose estimates ranged from zero to 20 Gy for total dose (0-1.7 Gy and 0-20 Gy for dose from external and internal sources, respectively). The ratio of internal to external dose generally increased with increasing distance, reflecting a shift towards smaller particle sizes at greater distances and more effective transfer of small particles through the foodchain. Dose-response analysis was focused on variation of nodule prevalence by sex, age at screening, measured thyroid volume, and reconstructed thyroid dose from external (mainly gamma-ray) and internal (mainly 131 I) radiation sources. Nodule prevalence was markedly higher among women and increased significantly with increasing age at screening and with thyroid volume. Highly significant dose responses were observed for nodule prevalence as a function of total thyroid dose and, in a separate analysis, of doses from internal and external sources as distinct independent variables; dose response was linear for total dose 131 I cf. x ray with respect to thyroid cancer as an endpoint, based on theoretical, experimental, and epidemiological data

  7. Assessment of internal doses

    CERN Document Server

    Rahola, T; Falk, R; Isaksson, M; Skuterud, L

    2002-01-01

    There is a definite need for training in dose calculation. Our first course was successful and was followed by a second, both courses were fully booked. An example of new tools for software products for bioassay analysis and internal dose assessment is the Integrated Modules for Bioassay Analysis (IMBA) were demonstrated at the second course. This suite of quality assured code modules have been adopted in the UK as the standard for regulatory assessment purposes. The intercomparison measurements are an important part of the Quality Assurance work. In what is known as the sup O utside workers ' directive it is stated that the internal dose measurements shall be included in the European Unions supervision system for radiation protection. The emergency preparedness regarding internal contamination was much improved by the training with and calibration of handheld instruments from participants' laboratories. More improvement will be gained with the handbook giving practical instructions on what to do in case of e...

  8. Thyroid Dose Estimates for a Cohort of Belarusian Children Exposed to Radiation from the Chernobyl Accident

    Science.gov (United States)

    Drozdovitch, Vladimir; Minenko, Victor; Khrouch, Valeri; Leshcheva, Svetlana; Gavrilin, Yury; Khrutchinsky, Arkady; Kukhta, Tatiana; Kutsen, Semion; Luckyanov, Nickolas; Shinkarev, Sergey; Tretyakevich, Sergey; Trofimik, Sergey; Voillequé, Paul; Bouville, André

    2013-01-01

    The U.S. National Cancer Institute, in collaboration with the Belarusian Ministry of Health, is conducting a study of thyroid cancer and other thyroid diseases in a cohort of about 12,000 persons who were exposed to fallout from the Chernobyl accident in April 1986. The study subjects were 18 years old or younger at the time of exposure and resided in Belarus in the most contaminated areas of the Gomel and Mogilev Oblasts, as well as in the city of Minsk. All cohort members had at least one direct thyroid measurement made in April–June 1986. Individual data on residential history, consumption of milk, milk products and leafy vegetables as well as administration of stable iodine were collected for all cohort members by means of personal interviews conducted between 1996 and 2007. Based on the estimated 131I activities in the thyroids, which were derived from the direct thyroid measurements, and on the responses to the questionnaires, individual thyroid doses from intakes of 131I were reconstructed for all cohort members. In addition, radiation doses to the thyroid were estimated for the following minor exposure pathways: (a) intake of short-lived 132I, 133I and 132Te by inhalation and ingestion; (b) external irradiation from radionuclides deposited on the ground; and (c) ingestion intake of 134Cs and 137Cs. Intake of 131I was the major pathway for thyroid exposure; its mean contribution to the thyroid dose was 92%. The thyroid doses from 131I intakes varied from 0.5 mGy to almost 33 Gy; the mean was estimated to be 0.58 Gy, while the median was 0.23 Gy. The reconstructed doses are being used to evaluate the risk of thyroid cancer and other thyroid diseases in the cohort. PMID:23560632

  9. Dose distribution in the thyroid gland following radiation therapy of breast cancer--a retrospective study.

    Science.gov (United States)

    Johansen, S; Reinertsen, K V; Knutstad, K; Olsen, D R; Fosså, S D

    2011-06-09

    To relate the development of post-treatment hypothyroidism with the dose distribution within the thyroid gland in breast cancer (BC) patients treated with loco-regional radiotherapy (RT). In two groups of BC patients postoperatively irradiated by computer tomography (CT)-based RT, the individual dose distributions in the thyroid gland were compared with each other; Cases developed post-treatment hypothyroidism after multimodal treatment including 4-field RT technique. Matched patients in Controls remained free for hypothyroidism. Based on each patient's dose volume histogram (DVH) the volume percentages of the thyroid absorbing respectively 20, 30, 40 and 50 Gy were then estimated (V20, V30, V40 and V50) together with the individual mean thyroid dose over the whole gland (MeanTotGy). The mean and median thyroid dose for the included patients was about 30 Gy, subsequently the total volume of the thyroid gland (VolTotGy) and the absolute volumes (cm3) receiving respectively thyroid gland receivingthyroid glands after loco-radiotherapy of BC, the risk of post-treatment hypothyroidism depends on the volume of the thyroid gland.

  10. Thyroid doses and risk to paediatric patients undergoing neck CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Spampinato, Maria Vittoria; Tipnis, Sameer; Huda, Walter [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Tavernier, Joshua [Medical University of South Carolina, College of Medicine, Charleston, SC (United States)

    2015-07-15

    To estimate thyroid doses and cancer risk for paediatric patients undergoing neck computed tomography (CT). We used average CTDI{sub vol} (mGy) values from 75 paediatric neck CT examinations to estimate thyroid dose in a mathematical anthropomorphic phantom (ImPACT Patient CT Dosimetry Calculator). Patient dose was estimated by modelling the neck as mass equivalent water cylinder. A patient size correction factor was obtained using published relative dose data as a function of water cylinder size. Additional correction factors included scan length and radiation intensity variation secondary to tube-current modulation. The mean water cylinder diameter that modelled the neck was 14 ± 3.5 cm. The mathematical anthropomorphic phantom has a 16.5-cm neck, and for a constant CT exposure, would have thyroid doses that are 13-17 % lower than the average paediatric patient. CTDI{sub vol} was independent of age and sex. The average thyroid doses were 31 ± 18 mGy (males) and 34 ± 15 mGy (females). Thyroid cancer incidence risk was highest for infant females (0.2 %), lowest for teenage males (0.01 %). Estimated absorbed thyroid doses in paediatric neck CT did not significantly vary with age and gender. However, the corresponding thyroid cancer risk is determined by gender and age. (orig.)

  11. Chernobyl accident: revision of individual thyroid dose estimates for the children included in the cohort of the Belarusian-American study

    International Nuclear Information System (INIS)

    Minenko, Victor; Shemyakina, Elena; Tretyakevich, Sergey

    2000-01-01

    The observed sharp increase in the number of childhood-thyroid-cancer cases in Belarus that has occurred since the Chernobyl accident stimulated the undertaking in 1994 of a long-term American-Belarusian cohort study. That epidemiological study is aimed at revealing the carcinogenic effectiveness of 131 I (the main contributor to the thyroid exposure) and at estimating the risk coefficient of thyroid disease, especially thyroid cancer, as a function of age at exposure. It is planned to follow actively 15,000 children (aged 0-18 at the time of the accident) sampled among about 40,000 who had their thyroid measured in vivo in 1986. Such direct thyroid measurements provide the basis for the initial thyroid dose estimates that have been established for the 40,000 children in the absence of personal interviews. As of August 1999, approximately 5,000 cohort subjects have been screened and interviewed. The initial estimates of individual thyroid dose are being revised for all of the cohort subjects that have been screened. The revision procedure of the 131 I thyroid dose assessment consists of two parts: (1) re-analysis of the direct thyroid measurements and (2) analysis of the responses to the personal interview which were conducted in order to determine the kinetics of the radioiodine intake by the cohort subjects. Revised estimates of thyroid dose resulting from 131 I intake are presented for a sample of 1,000 subjects residing in various areas of Belarus. The reason for the differences between the initial and the revised thyroid dose estimates are discussed. In addition to the estimation of the internal thyroid dose from 131 I, three minor contributors to the thyroid exposure are considered separately: (1) the internal exposure resulting from intake of short-lived radioiodines and radiotelluriums, (2) the internal exposure resulting from intake of other radionuclides (mainly radiocesiums), and (3) external exposure from radionuclides deposited on the ground. Examples

  12. Measurement of Thyroid Dose by TLD arising from Radiotherapy of Breast Cancer Patients from Supraclavicular Field

    Directory of Open Access Journals (Sweden)

    Farhood B.

    2016-06-01

    Full Text Available Background: Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary fields. Objective: In the present study, due to the presence of sensitive organ such as thyroid inside the supraclavicular field, thyroid dose and its effective factors were investigated. Materials and Methods: Thyroid dose of 31 female patients of breast cancer with involved supraclavicular lymph nodes which had undergone radiotherapy were measured. For each patient, three TLD-100 chips were placed on their thyroid gland surface, and thyroid doses of patients were measured. The variables of the study include shield shape, the time of patient’s setup, the technologists’ experience and qualification. Finally, the results were analyzed by ANOVA test using SPSS 11.5 software. Results: The average age of the patients was 46±10 years. The average of thyroid dose of the patients was 140±45 mGy (ranged 288.2 and 80.8 in single fraction. There was a significant relationship between the thyroid dose and shield shape. There was also a significant relationship between the thyroid dose and the patient’s setup time. Conclusion: Beside organ at risk such as thyroid which is in the supraclavicular field, thyroid dose possibility should be reduced. For solving this problem, an appropriate shield shape, the appropriate time of the patient’s setup, etc. could be considered.

  13. Ultrasound assessment of thyroid gland volume in diabetic patients without overt thyroid disease.

    Science.gov (United States)

    Nduka, Christopher C; Adeyekun, Ademola A

    2016-01-01

    Diabetes mellitus and thyroid disease are known to mutually influence each other. Thyroid disease can worsen glycaemic control in diabetes, and patients with diabetes mellitus have increased incidence of thyroid disorders such as increase in size, compared to the normal population. The aim of the study was to sonographically assess thyroid gland volume in Nigerian adult diabetic patients and compare with apparently healthy adults (controls). The study setting was the Department of Radiology, University of Benin Teaching Hospital (UBTH) Nigeria. The thyroid gland in 120 diabetic subjects and equal number of apparently healthy controls was scanned with a 5-12 MHz linear transducer of a SONOACE X4 Machine. Thyroid gland volume was assessed. Statistical analysis was done with Statistical Package for the Social Sciences (SPSS) version 17 (SPSS Inc, Chicago, IL, USA). Diabetics had significantly increased thyroid volume compared to age matched male and female control subjects (11.5 ± 5.2 cm3 vs 7.4 ± 1.9 cm3; Pthyroid volume among diabetics. Diabetics have higher thyroid gland dimensions, compared to apparently healthy subjects. Gland proliferation from circulating insulin may play a role. This is not influenced by gender.

  14. Uncertainty of the thyroid dose conversion factor for inhalation intakes of 131I and its parametric uncertainty

    International Nuclear Information System (INIS)

    Harvey, R. P.; Hamby, D. M.; Palmer, T. S.

    2006-01-01

    Inhalation exposures of 131 I may occur in the physical form of a gas as well as a particulate. The physical characteristics pertaining to these different types of releases influence the intake and subsequent dose to an exposed individual. The thyroid dose received is influenced by the route through which 131 I enters the body and its subsequent clearance, absorption and movement throughout the body. The radioactive iodine taken up in the gas-exchange tissues is cleared to other tissues or absorbed into the bloodstream of the individual and transferred to other organs. Iodine in the circulatory system is then taken up by the thyroid gland with resulting dose to that tissue. The magnitude of and uncertainty in the thyroid dose is important to the assessment of individuals exposed to airborne releases of radioiodine. Age- and gender-specific modelling parameters have resulted in significant differences between gas uptake, particulate deposition and inhalation dose conversion factors for each age and gender group. Inhalation dose conversion factors and their inherent uncertainty are markedly affected by the type of iodine intake. These differences are expected due to the modelling of particulate deposition versus uptake of gas in the respiratory tract. Inhalation dose estimates via iodine gases are very similar and separate classifications may not be necessarily based on this assessment. (authors)

  15. Treatment of diffuse toxic goiter with 131I. at doses of 80ΜCi/g of thyroid tissue

    International Nuclear Information System (INIS)

    Ochoa Torres, Francisco; Knight Bermudez, Hugh Gregorio; Alavez Martin, Ernesto

    2004-01-01

    131 I. has proved to be the most efficient therapeutics in the treatment of diffuse toxic goiter (DTG). However, there is no consensus on the dose to be administered: fixed dose or according to the functional activity of the thyroid and its size. In order to evaluate the therapeutical results at a dose of 80 ΜCi/g of thyroid tissue, estimated by palpation and without having into account the functional activity of thyroid and whether they had received propylthiouracil (PTU) previously , 61 patients diagnosed by the clinic, as well as determinations of TSH and total T4, were studied in individuals aged 20-80 of both sexes, with a thyroid size over 30 g. The postoperative follow-up was performed every 2 months for 3 years by the same specialist and with identical procedures. The efficiency of the treatment with the first dose was 85.2 %. The frequency of hypothyroidism at 3 years of evolution was 29.5. The age of the patient, the sex, the goiter size and the treatment with PTU did not influence on the response to it. The advantages showed by the method were: high efficiency, the dose of 131 I. may be easily calculated, simple application, decrease of the cost, since it is not necessary to assess the functional state of the gland, and reduction of visits

  16. Treatment of diffuse toxic goiter with 131I doses of 80 μCi/g of thyroid tissue

    International Nuclear Information System (INIS)

    Ochoa Torres, Francisco; Knight Bermudez, Hugh Gregorio; Alavez Martin, Ernesto

    2004-01-01

    131 I has proved to be the most efficient therapeutics in the treatment of diffuse toxic goiter (DTG). However, there is no consensus on the dose to be administered: fixed dose or according to the functional activity of the thyroid and its size. In order to evaluate the therapeutical results at a dose of 80 μCi/g of thyroid tissue, estimated by palpation and without having into account the functional activity of thyroid and whether they had received propylthiouracil (PTU) previously, 61 patients diagnosed by the clinic, as well as determinations of TSH and total T4, were studied in individuals aged 20-80 of both sexes, with a thyroid size over 30 g. The postoperative follow-up was performed every 2 months for 3 years by the same specialist and with identical procedures. The efficiency of the treatment with the first dose was 85.2 %. The frequency of hypothyroidism at 3 years of evolution was 29.5. The age of the patient, the sex, the goiter size and the treatment with PTU did not influence on the response to it. The advantages showed by the method were: high efficiency, the dose of 131 I may be easily calculated, simple application, decrease of the cost, since it is not necessary to assess the functional state of the gland, and reduction of visits

  17. [Thyroiditis].

    Science.gov (United States)

    Buffet, Camille; Groussin, Lionel

    2013-02-01

    The diagnosis of thyroiditis encompasses a broad spectrum of thyroid disorders. Analysis of signs and symptoms, biochemical changes, neck ultrasound characteristics and radioactive iodine uptake values allows an accurate diagnosis. Recent studies of the whole genome have helped to identify many susceptibility genes for autoimmune thyroiditis. However, none of these genes contribute to a significant increase in risk of developing this thyroiditis. Clinical awareness of the characteristic presentations of exceptional thyroiditis (acute suppurative thyroiditis, Riedel's thyroiditis) is an important issue. Selenium administration seems to be beneficial for reducing the incidence of thyroiditis. Finally, certain drug-induced thyroiditis remains a therapeutic challenge for the physician.

  18. Dose. Detriment. Limit assessment

    International Nuclear Information System (INIS)

    Breckow, J.

    2015-01-01

    One goal of radiation protection is the limitation of stochastic effects due to radiation exposure. The probability of occurrence of a radiation induced stochastic effect, however, is only one of several other parameters which determine the radiation detriment. Though the ICRP-concept of detriment is a quantitative definition, the kind of detriment weighting includes somewhat subjective elements. In this sense, the detriment-concept of ICRP represents already at the stage of effective dose a kind of assessment. Thus, by comparing radiation protection standards and concepts interconvertible or with those of environment or occupational protection one should be aware of the possibly different principles of detriment assessment.

  19. Irradiation doses on thyroid gland during the postoperative irradiation for breast cancer

    Directory of Open Access Journals (Sweden)

    Mustafa Akın

    2014-01-01

    Conclusions: In majority of the node-positive breast cancer patients treated with 3D CRT, the thyroid gland was exposed to considerable doses. On the other hand, for 44% of the patients are at risk for developing thyroid function abnormalities which should be considered during the routine follow-up.

  20. Absorbed dose by thyroid in case of nuclear accidents; Dose absorvida pela tireoide em casos de acidentes nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia; Attie, Marcia Regina Pereira [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil). Dept. de Fisica; Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Amaral, Ademir [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2011-07-01

    Radioisotopes of iodine are produced in abundance in nuclear fission reactions, and great amounts of radioiodine may be released into the environment in case of a nuclear reactor accident. Thyroid gland is among the most radiosensitive organs due to its capacity to concentrate iodine. The aim of this work was to evaluate the importance of contributions of internally deposited iodines ({sup 131}I, {sup 132}I, {sup 133}I, {sup 134}I and {sup 135}I) to the dose absorbed to thyroid follicle and to the whole organ, after internal contamination by those isotopes. For internal dose calculation, the code of particles transport MCNP4C was employed. The results showed that, in case of nuclear accidents, the contribution of short-lived iodines for total dose is about 45% for thyroid of newborn and about 40% for thyroid of adult. Thus, these contributions should not be neglected in a prospective evaluation of risks associated to internal contamination by radioactive iodine. (author)

  1. Contributions of short-lived radioiodines to thyroid doses received by evacuees from the Chernobyl area estimated using early in vivo activity measurements

    International Nuclear Information System (INIS)

    Balonov, M.; Kaidanovsky, G.; Zvonova, I.; Kovtun, A.; Bouville, A.; Luckyanov, L.; Voilleque, P.

    2003-01-01

    A series of in-vivo gamma spectrometric measurements of 65 people, evacuated from Pripyat 1.5 days after the Chernobyl Nuclear Power Plant Unit 4 explosion was performed in St. Petersburg, Russia, as early as 30 April 1986. The historical spectra and interviews were recently processed and the results used for thyroid dose estimation. Activities of 131 I in thyroid and 132 Te in lungs were determined easily; for estimation of 132 I and 133 I activities in thyroid, sophisticated methods of spectra processing were developed. According to thyroid measurement data, the mean ratio of 133 I/ 131 I activities (at the time of the accident) inhaled by residents of Pripyat was 2.0. The mean ratio of thyroid dose from 133 I inhalation to that caused by 131 I amounts to 0.3, which confirms accuracy of dose estimates based on the evolution of the Chernobyl accident. The mean ratio of 132 I activity in thyroid to that of 132 Te in lungs was assessed from the human measurement data to be 0.2, which is in reasonable agreement with the metabolic properties of these radionuclides. The mean ratio of thyroid dose from 132 I originating from 132 Te deposited in lungs to the dose caused by 131 I was 0.13 ± 0.02 for Pripyat residents who did not take KI pills and 0.9 ± 0.1 for persons who took KI pills. Thus, the contribution of short-lived radioiodines to total thyroid dose of Pripyat residents, which was on average 30% for persons who did not apply stable iodine prophylaxis, and about 50% for persons who took KI pills on 26-27 April, should be accounted for in the assessment of thyroid health effects. (author)

  2. Using body mass index to predict optimal thyroid dosing after thyroidectomy.

    Science.gov (United States)

    Ojomo, Kristin A; Schneider, David F; Reiher, Alexandra E; Lai, Ngan; Schaefer, Sarah; Chen, Herbert; Sippel, Rebecca S

    2013-03-01

    Current postoperative thyroid replacement dosing is weight based, with adjustments made after thyroid-stimulating hormone values. This method can lead to considerable delays in achieving euthyroidism and often fails to accurately dose over- and underweight patients. Our aim was to develop an accurate dosing method that uses patient body mass index (BMI) data. A retrospective review of a prospectively collected thyroid database was performed. We selected adult patients undergoing thyroidectomy, with benign pathology, who achieved euthyroidism on thyroid hormone supplementation. Body mass index and euthyroid dose were plotted and regression was used to fit curves to the data. Statistical analysis was performed using STATA 10.1 software (Stata Corp). One hundred twenty-two patients met inclusion criteria. At initial follow-up, only 39 patients were euthyroid (32%). Fifty-three percent of patients with BMI >30 kg/m(2) were overdosed, and 46% of patients with BMI regression equation was derived for calculating initial levothyroxine dose (μg/kg/d = -0.018 × BMI + 2.13 [F statistic = 52.7, root mean square error of 0.24]). The current standard of weight-based thyroid replacement fails to appropriately dose underweight and overweight patients. Body mass index can be used to more accurately dose thyroid hormone using a simple formula. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Thyroid doses in Belarus resulting from the Chernobyl accident: comparison of the estimates based on direct thyroid measurements and on measurements of 131I in milk

    International Nuclear Information System (INIS)

    Shinkarev, Sergey; Gavrilin, Yury; Khrouch, Valery; Savkin, Mikhail; Bouville, Andre; Luckyanov, Nicholas

    2008-01-01

    A substantial increase of childhood cancer cases observed in Belarus, Ukraine and Russia after the Chernobyl accident has been associated with thyroid exposure to radio iodines following the accident. A large number of direct thyroid measurements (i.e. measurement of the exposure rate near the thyroid of the subject)were conducted in Belarus during a few weeks after the accident. Individual thyroid doses based on results of the direct thyroid measurements were estimated for about 126,000 Belarusian residents and settlement-average thyroid doses for adults were calculated for 426 contaminated settlements in Gomel and Mogilev Oblasts. Another set of settlement-average thyroid doses for adults was estimated based on results of activity measurements in milk samples for 28 settlements (with not less than 2 spectrometric measurements) and 155 settlements (with not less than 5 total beta-activity measurements) in Gomel and Mogilev Oblasts. Concentrations of 131 I in milk were derived from these measurements. In the estimation of this set of thyroid doses, it was assumed that adults consumed 0.5 L d -1 of milk locally produced. The two sets of dose estimates were compared for 47 settlements, for which simultaneously were available a dose estimate based on thyroid measurements and a dose estimate based either on spectrometric or radiometric milk data. The settlement average thyroid doses based on milk activity measurements were higher than those based on direct thyroid measurements by a factor of 1.8 for total beta-activity measurements (30 settlements were compared) and by a factor of 2.4 for spectrometric measurements (17 settlements). This systematic difference can be explained by overestimation of the milk consumption rate used in the calculation of the milk-based thyroid doses and/or by application of individual countermeasures by people. (author)

  4. Effect of changes of personal interview data on estimation of individual thyroid dose

    International Nuclear Information System (INIS)

    Tret'yakevich, S.S.

    2008-01-01

    Results of initial and second personal interviews are analyzed for more than one thousand men. Change of individual thyroid dose is considered as consequence of changes of personal interview data. (authors)

  5. Reconstruction of thyroid doses for the population of Belarus following the Chernobyl accident

    International Nuclear Information System (INIS)

    Gavrilin, Y.I.; Khrouch, V.T.; Shinkarev, S.M.; Minenko, V.F.; Drozdovich, V.V.; Ulanovsky, A.V.; Bouville, A.C.

    1995-09-01

    As a sequela to the large release of 131 I from the accident at the Chernobyl Nuclear Power Plant, an expected late effect is thyroid cancer, especially in children. In anticipation of this problem, hundreds of thousands of measurements of thyroid glands were made with survey meters. Much attention was also focused on measuring the deposition density of 137 Cs. The expectation was that the latter measurement could be a good surrogate for the deposition density of 131 I, so that ecological models could be used to reconstruct thyroid doses in locations where no direct measurements of thyroid activity were made. However, this assumption has been seriously questioned, and there is interest in a more suitable surrogate that can still be measured even nine years or more after the accident. The purpose of this paper is to discuss the reconstruction of thyroid doses for a case-control study of childhood-thyroid cancer that has just been concluded, to discuss the reconstruction of thyroid doses for a current cohort study of childhood-thyroid cancer, and to discuss the use of 129 I as a surrogate for the deposition density of 131 I

  6. Dose distribution in the thyroid gland following radiation therapy of breast cancer-a retrospective study

    International Nuclear Information System (INIS)

    Johansen, S; Reinertsen, KV; Knutstad, K; Olsen, DR; Fosså, SD

    2011-01-01

    To relate the development of post-treatment hypothyroidism with the dose distribution within the thyroid gland in breast cancer (BC) patients treated with loco-regional radiotherapy (RT). In two groups of BC patients postoperatively irradiated by computer tomography (CT)-based RT, the individual dose distributions in the thyroid gland were compared with each other; Cases developed post-treatment hypothyroidism after multimodal treatment including 4-field RT technique. Matched patients in Controls remained free for hypothyroidism. Based on each patient's dose volume histogram (DVH) the volume percentages of the thyroid absorbing respectively 20, 30, 40 and 50 Gy were then estimated (V20, V30, V40 and V50) together with the individual mean thyroid dose over the whole gland (MeanTotGy). The mean and median thyroid dose for the included patients was about 30 Gy, subsequently the total volume of the thyroid gland (VolTotGy) and the absolute volumes (cm 3 ) receiving respectively < 30 Gy and ≥ 30 Gy were calculated (Vol < 30 and Vol ≥ 30) and analyzed. No statistically significant inter-group differences were found between V20, V30, V40 and V50Gy or the median of MeanTotGy. The median VolTotGy in Controls was 2.3 times above VolTotGy in Cases (ρ = 0.003), with large inter-individual variations in both groups. The volume of the thyroid gland receiving < 30 Gy in Controls was almost 2.5 times greater than the comparable figure in Cases. We concluded that in patients with small thyroid glands after loco-radiotherapy of BC, the risk of post-treatment hypothyroidism depends on the volume of the thyroid gland

  7. Effect of Hashimoto thyroiditis on low-dose radioactive-iodine remnant ablation.

    Science.gov (United States)

    Kwon, Hyungju; Choi, June Young; Moon, Jae Hoon; Park, Hyo Jin; Lee, Won Woo; Lee, Kyu Eun

    2016-04-01

    Radioactive-iodine remnant ablation is an integral part of the papillary thyroid carcinoma (PTC) treatment. Although a minimum dose is usually recommended, there is controversy as to whether the low-dose (1100 MBq) radioactive-iodine remnant ablation is adequate for selected patients. A retrospective cohort study was conducted on 691 patients. Patients with no remnant thyroid on the follow-up whole body scan and low stimulated thyroglobulin (sTg) level (Hashimoto thyroiditis based on histopathology diagnosis (odds ratio [OR] = 3.23; p Hashimoto thyroiditis and elevated sTg are negative predictive factors for successful low-dose radioactive-iodine remnant ablation treatment. An appropriate risk-adjusted approach may improve the efficacy of radioactive-iodine remnant ablation treatment. © 2015 Wiley Periodicals, Inc. Head Neck 38: E730-E735, 2016. © 2015 Wiley Periodicals, Inc.

  8. Application of Monte Carlo method for dose calculation in thyroid follicle

    International Nuclear Information System (INIS)

    Silva, Frank Sinatra Gomes da

    2008-02-01

    The Monte Carlo method is an important tool to simulate radioactive particles interaction with biologic medium. The principal advantage of the method when compared with deterministic methods is the ability to simulate a complex geometry. Several computational codes use the Monte Carlo method to simulate the particles transport and they have the capacity to simulate energy deposition in models of organs and/or tissues, as well models of cells of human body. Thus, the calculation of the absorbed dose to thyroid's follicles (compound of colloid and follicles' cells) have a fundamental importance to dosimetry, because these cells are radiosensitive due to ionizing radiation exposition, in particular, exposition due to radioisotopes of iodine, because a great amount of radioiodine may be released into the environment in case of a nuclear accidents. In this case, the goal of this work was use the code of particles transport MNCP4C to calculate absorbed doses in models of thyroid's follicles, for Auger electrons, internal conversion electrons and beta particles, by iodine-131 and short-lived iodines (131, 132, 133, 134 e 135), with diameters varying from 30 to 500 μm. The results obtained from simulation with the MCNP4C code shown an average percentage of the 25% of total absorbed dose by colloid to iodine- 131 and 75% to short-lived iodine's. For follicular cells, this percentage was of 13% to iodine-131 and 87% to short-lived iodine's. The contributions from particles with low energies, like Auger and internal conversion electrons should not be neglected, to assessment the absorbed dose in cellular level. Agglomerative hierarchical clustering was used to compare doses obtained by codes MCNP4C, EPOTRAN, EGS4 and by deterministic methods. (author)

  9. Intercomparison of iodine thyroid doses estimated for people living in urban and rural environments

    International Nuclear Information System (INIS)

    Voigt, G.

    2000-01-01

    The radioecological model ECOSYS, developed in GSF-Institut fuer Strahlenschutz has been applied to calculate thyroid doses to the population due to I-131 exposures after the Chernobyl accident. The main contribution to the thyroid doses calculated is given by the consumption of milk and vegetables. Results are presented taking into account the different activity concentrations measured in milk of private family cows and mixed collective milk of a creamery in upper Bavaria, as well as different consumption behaviour of children and adults in rural and urban areas. Thyroid doses due to different milk consumption habits and a different milk origin in adults living in urban environments are estimated to be up to 12 times, in children up to 3 times lower than those estimated for rural environments. The dose contribution by vegetables, however, in any case exceeded the one by milk because of the high intake rates for the case investigated here. These values, however, may be overestimates for vegetables and have a very high uncertainty. For adults total thyroid dose by ingestion was higher in rural areas by a factor of 1.4, for children at the age of 10 years, total thyroid dose by ingestion was 1.5 times higher in urban environments for the conditions described here. (author)

  10. Thyroid doses from external gamma-exposure following the Chernobyl accident

    International Nuclear Information System (INIS)

    Tretyakevich, Sergey; Kukhta, Tatyana; Minenko, Victor; Drozdovitch, Vladimir; Luckyanov, Nickolas; Gavrilin, Yury; Khrouch, Valeri; Shinkarev, Sergey

    2008-01-01

    Full text: An increase of thyroid cancer incidence among children in Belarus has been observed after the Chernobyl accident. The main contributor to the thyroid dose was caused by 131 I intake with fresh milk in 1986. Other contributions to the thyroid dose (external gamma-exposure, short-lived iodine isotopes, internal radiocesium) were small in comparison to the dose from 131 I intakes soon after the accident. However, exposures to external radiation continued for a number of years after the accident. Thyroid doses from external gamma-exposure following the Chernobyl accident were mainly caused by gamma-exposure to 24 nuclides: 95 Zr, 95 Nb, 99 Mo, 99 mTc, 103 Ru, 103m Rh, 106 Ru, 125 Sb, 125m Te, 131m Te, 131 I, 132 Te, 132 I, 133 I, 135 I, 134 Cs, 136 Cs, 137 Cs, 140 Ba, 140 La, 141 Ce, 144 Ce, 144 Pr, 239 Np. Data of personal interview were used to take into account the personal residence history for the time elapsed from the Chernobyl accident until the interview (10 to 15 years later). Cumulative thyroid doses caused by external gamma-exposure during the passage of the radioactive cloud and from the ground contamination following the Chernobyl accident have been reconstructed. The median thyroid dose from external gamma-exposure to ∼11,770 cohort members of an epidemiological study was estimated to be ∼6 mGy. There are ∼3,400 persons with external dose estimates that exceed 20 mGy. Exposure from radionuclides deposited on the ground was the main source of external dose. The contribution from the passing radioactive cloud to external dose was found to be negligible. (author)

  11. Iodine-131 dose dependent gene expression in thyroid cancers and corresponding normal tissues following the Chernobyl accident.

    Directory of Open Access Journals (Sweden)

    Michael Abend

    Full Text Available The strong and consistent relationship between irradiation at a young age and subsequent thyroid cancer provides an excellent model for studying radiation carcinogenesis in humans. We thus evaluated differential gene expression in thyroid tissue in relation to iodine-131 (I-131 doses received from the Chernobyl accident. Sixty three of 104 papillary thyroid cancers diagnosed between 1998 and 2008 in the Ukrainian-American cohort with individual I-131 thyroid dose estimates had paired RNA specimens from fresh frozen tumor (T and normal (N tissue provided by the Chernobyl Tissue Bank and satisfied quality control criteria. We first hybridized 32 randomly allocated RNA specimen pairs (T/N on 64 whole genome microarrays (Agilent, 4×44 K. Associations of differential gene expression (log(2(T/N with dose were assessed using Kruskall-Wallis and trend tests in linear mixed regression models. While none of the genes withstood correction for the false discovery rate, we selected 75 genes with a priori evidence or P kruskall/P trend <0.0005 for validation by qRT-PCR on the remaining 31 RNA specimen pairs (T/N. The qRT-PCR data were analyzed using linear mixed regression models that included radiation dose as a categorical or ordinal variable. Eleven of 75 qRT-PCR assayed genes (ACVR2A, AJAP1, CA12, CDK12, FAM38A, GALNT7, LMO3, MTA1, SLC19A1, SLC43A3, ZNF493 were confirmed to have a statistically significant differential dose-expression relationship. Our study is among the first to provide direct human data on long term differential gene expression in relation to individual I-131 doses and to identify a set of genes potentially important in radiation carcinogenesis.

  12. Effects of low-dose fractionated external irradiation on metabolic and structural characteristics of rat thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Nadolnik, L.; Niatsetskaya, Z. [Institute of Biochemistry, National Academy of Sciences of Belarus, Grodno (Belarus)

    2006-07-01

    Full text of publication follows: The problem of thyroid radiosensitivity to the effect of low dose external ionizing irradiation presently seems to be the least studied, and the experimental findings - the most contradictory. The aim of the work was to study the effects of long-term low-dose fractionated irradiation on the iodide metabolism and structure of the thyroid. Female Wistar rats weighing 140-160 g were irradiated 20 times (5 times a week, for 4 weeks) using a 60 Co installation. The single absorbed doses were 0.1, 0.25 and 0.5 Gy and the total ones - 2.0, 5.0 and 10.0 Gy, respectively. The animals were decapitated after 1 day, 4 and 24 weeks following the last irradiation. The thyroid tissue was used to assay for thyro-peroxidase (T.P.O.) activity as well as total, protein -bound and free iodide concentrations. Microscopic and morphometric examination of histologic thyroid preparations was carried out. Blood was assayed for thyroxin (T4) and triiodothyronine (T3) concentrations. After a day following the irradiation, the thyroid showed a pronounced increase in the concentration of total iodide (30.0-54.4%) as well in that of free (32.1-60.8%) and protein-bound ones (24.4-37.4%). The most pronounced iodide concentration elevation was noted in the 0.1 -Gy animals, with thyroid T.P.O. activity being raised by 48.0%. Only the 0.5 Gy-group had 1.4-1.5-fold reduced thyroid hormone levels. Four weeks after the irradiation, studied parameters of irradiated rats were brought back to the control values, except for the 0.5 Gy-group. However, after 24-weeks, the 0.5-and 0.25- irradiated rats experienced a 12-20% thyroid weight elevation in comparison with the control. The thyroid of these animals demonstrated reduced contents of total and free iodide as well as T.P.O. activity by 24.5 and 34.8%. The 0.1 Gy-group had a 1.7-fold increased T.P.O. activity. The concentration of the thyroid hormones was maintained diminished only in the 0.5 Gy -irradiated group. However

  13. The effect of low-dose ionizing radiation on structural functional state of thyroid gland. Communication 2

    International Nuclear Information System (INIS)

    Lukashova, O.P.

    1999-01-01

    Twelve rabbits were used to study the ultrastructure of thyroid cells after mercazolilum administration during 2.5 month (1 mg/kg of the body mass) to intact and exposed to total x-ray radiation at the total dose of 0.75 Gy animals. Prolonged administration of mercazolilum to intact rabbits causes the development of considerable morpho functional changes in the thyroid gland suggesting disturbances of thyroid secretion. 2-3 month after the preparation withdrawal thyroid 's ultrastructure restores almost completely. Mercazolilum administration to the irradiated rabbits prevents the development of structural disturbances in the thyroid epithelium characteristic for the action of separate factors. Thyroid ultrastructure in rabbits 2-3 month after the preparation withdrawal in similar to that observed at irradiation only. Normalization of thyroid ultrastructure at administration of mercazolilum to the irradiated animals suggest that inhibition of thyroid activity after the exposure to radiation is reversible and can be due to disturbances in thyroid homeostasis regulation

  14. Quantitative assessment of thyroid gland elasticity with shear-wave elastography in pediatric patients with Hashimoto's thyroiditis.

    Science.gov (United States)

    Kandemirli, Sedat Giray; Bayramoglu, Zuhal; Caliskan, Emine; Sari, Zeynep Nur Akyol; Adaletli, Ibrahim

    2018-01-18

    Hashimoto's thyroiditis is the most common autoimmune thyroid disorder in the pediatric age range. Measurement of thyroid gland size is an essential component in evaluation and follow-up of thyroid pathologies. Along with size, tissue elasticity is becoming a more commonly used parameter in evaluation of parenchyma in inflammatory diseases. The aim of the current study was to assess thyroid parenchyma elasticity by shear-wave elastography in pediatric patients with Hashimoto's thyroiditis; and compare the elasticity values to a normal control group. In this study; thyroid glands of 59 patients with a diagnosis of Hashimoto's thyroiditis based on ultrasonographic and biochemical features, and 26 healthy volunteers without autoimmune thyroid disease and thyroid function disorders, were evaluated with shear-wave elastography. Patients with Hashimoto thyroiditis were further subdivided into three categories based on gray-scale ultrasonography findings as focal thyroiditis (grade 1), diffuse thyroiditis (grade 2), and fibrotic thyroid gland (grade 3). Patients with Hashimoto's thyroiditis (n = 59) had significantly higher elasticity values (14. 9 kPa; IQR 12.9-17.8 kPa) than control subjects (10.6 kPa; IQR 9.0-11.3 kPa) (p thyroiditis, 23 patients had focal thyroiditis involving less than 50% of the gland categorized as grade 1, 24 patients had diffuse involvement of the thyroid gland categorized as grade 2, and 12 patients had marked hyperechoic septations and pseudonodular appearance categorized as grade 3 on gray-scale ultrasound. Based on elastography, grade 3 patients had significantly higher elasticity values (19.7 kPa; IQR 17.8-21.5 kPa) than patients with grade 2 (15.5 kPa; IQR 14.5-17.8 kPa) and grade 1 thyroiditis (12.8 kPa; IQR 11.9-13.1 kPa) (p thyroiditis had significantly higher elasticity values than those with grade 1 thyroiditis (p thyroiditis. Our results indicate that shear-wave elastography could be used to evaluate the degree of

  15. Blood doses and remnant biokinetics after thyroid ablation therapy of differentiated thyroid cancer: withdrawal vs. rh TSH

    International Nuclear Information System (INIS)

    Lassmann, Michael; Haenscheid, Heribert; Luster, Markus; Reiners, Christoph; Ablation, Trial Study Group

    2005-01-01

    Full text: An international randomized multicenter trial (9 sites; North America: 5, Europe: 4) was carried out investigating the effectiveness of ablation therapy with 3.7 GBq 131 I in differentiated thyroid cancer. We present the results of the trial dosimetry assessments. 63 patients were randomized after thyroidectomy to either hypothyroidism (THW) or euthyroidism in combination with rh TSH (0.9 mg q d x 2, Thyrogen). The biokinetics and residence times (RT) of the remnants were assessed from 3 neck scans starting 48 h after administration. The blood doses (a surrogate for the bone marrow dose) were calculated from activity concentrations in blood samples and 131 I whole body retention measurements between 2 and 168 h after 131 I administration. The overall dosimetry results were calculated centrally (Wuerzberg) in an externally audited standardized data evaluation procedure. The patient ablation rate was 100%. The 48 h 131 I uptake was lower in the remnant tissue of the rh TSH group: 0.5 ± 0.7%; THW group: 0.9 ±1.0% (p=0.1), the effective half life showed smaller values for the THW group (48.0 ± 52.6 h vs. 67.6 ± 48.9 h, p=0.0116). The mean RT in the remnant tissue was shorter in the rh TSH group: 0.9 ± 1.3 h; THW group: 1.4 ± 1.5 h (p=0.1). A greater decrease in the mean percentage of administered activity in the blood at 48 h, and a lower mean residence time was seen in the rh TSH group: 0.8%, RT: 2.3 ± 0.7 h; THW group: 1.8% (p=0.0011), RT: 3.5 ± 1.63 h (p=0.0004). The mean specific blood dose was significantly lower (p<0.0001) in the rh TSH group (0.072 ± 0.017 mGy/MBq, blood vessel radius (VR):0.2 mm; 0.104 ± 0.025 mGy/MBq, VR: 5 mm) than in the Hypothyroid group (0.106 ± 0.037 mGy/MBq, VR: 0.2 mm; 0.158 ± 0.059 mGy/MBq, VR: 5 mm). Conclusion: Although the remnant RT tended to be lower in the rh TSH group the ablation rates in the 2 study arms were comparable. The radiation dose to the blood was significantly lower in the rh TSH group. This

  16. A dose-effect correlation for radioiodine ablation in differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Flux, Glenn D; Chittenden, Sarah J; Buckley, Susan; Hindorf, Cecilia [Royal Marsden NHS Foundation Trust, Department of Physics, Sutton, Surrey (United Kingdom); Haq, Masud; Newbold, Kate; Harmer, Clive L [Royal Marsden NHS Foundation Trust, Thyroid Unit, Sutton, Surrey (United Kingdom)

    2010-02-15

    The aim of this study was to determine the range of absorbed doses delivered to thyroid remnants, blood, and red marrow from fixed administrations of radioiodine and to ascertain whether the success of ablation is more dependent on these absorbed doses than on the administered activity. Twenty-three patients received 3,000 MBq radioiodine following near-total thyroidectomy. The maximum absorbed dose to remnants was calculated from subsequent single photon emission tomography scans. Absorbed doses delivered to blood and red marrow were calculated from blood samples and from whole-body retention measurements. The protein bound iodine (PBI) was also calculated. Maximum absorbed doses to thyroid remnants ranged from 7 to 570 Gy. Eighteen of the 23 patients had a successful ablation. A significant difference was seen between the absorbed doses delivered to thyroid remnants, blood, and red marrow for those patients that had a successful ablation compared to those with a failed ablation (p = 0.030, p = 0.043 and p = 0.048, respectively). The difference between the PBI values acquired at day 1 and day 6 were also indicative of response (p = 0.074). A successful ablation is strongly dependent on the absorbed dose to the thyroid remnant. Dosimetry-based personalized treatment can prevent both sub-optimal administrations, which entails further radioiodine therapy, and excessive administration of radioactivity, which increases the potential for radiation toxicity. (orig.)

  17. I-131 dose response for incident thyroid cancers in Ukraine related to the Chornobyl accident.

    Science.gov (United States)

    Brenner, Alina V; Tronko, Mykola D; Hatch, Maureen; Bogdanova, Tetyana I; Oliynik, Valery A; Lubin, Jay H; Zablotska, Lydia B; Tereschenko, Valery P; McConnell, Robert J; Zamotaeva, Galina A; O'Kane, Patrick; Bouville, Andre C; Chaykovskaya, Ludmila V; Greenebaum, Ellen; Paster, Ihor P; Shpak, Victor M; Ron, Elaine

    2011-07-01

    Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case-control studies, and studies of prevalent cancers. To address this limitation, we evaluated the dose-response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. The cohort consists of individuals radioactivity measurements taken within 2 months after the accident, environmental transport models, and interview data. Excess radiation risks were estimated using Poisson regression models. Sixty-five incident thyroid cancers were diagnosed during the second through fourth screenings and 73,004 person-years (PY) of observation. The dose-response relationship was consistent with linearity on relative and absolute scales, although the excess relative risk (ERR) model described data better than did the excess absolute risk (EAR) model. The ERR per gray was 1.91 [95% confidence interval (CI), 0.43-6.34], and the EAR per 10⁴ PY/Gy was 2.21 (95% CI, 0.04-5.78). The ERR per gray varied significantly by oblast of residence but not by time since exposure, use of iodine prophylaxis, iodine status, sex, age, or tumor size. I-131-related thyroid cancer risks persisted for two decades after exposure, with no evidence of decrease during the observation period. The radiation risks, although smaller, are compatible with those of retrospective and ecological post-Chornobyl studies.

  18. Absorbed dose measurement by the MIRD system in the 131-I treated Thyroid Cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Woon; Lim, Sang Mu; Kim, Chang Hui; Kim, Ki Sub; Cho, Jong Sio; Jeong, Jin Sung; Park, Heung Kyu; Kwon, Oh Jin [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1995-12-01

    Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administrated radiopharmaceuticals. With the biological distribution data and physical properties of the radionuclide, we can estimated the absorbed dose by the MIRD schema. For the thyroid cancer patients received high dose 131-I therapy, the absorbed dose to the bone marrow is limiting factor to the administered dose and the duration of admission is determined by the retained activity in the whole body. To the monitoring of whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity (Author).

  19. Reducing radiation doses to the breast, thyroid and gonads during diagnostic radiography

    International Nuclear Information System (INIS)

    Weatherburn, G.C.

    1983-01-01

    The measurement of doses to the gonads during radiography of the pelvis is discussed. Phantom measurements to estimate doses to the ovaries in antero-posterior (AP) and postero-anterior (PA) projections of the pelvis showed that the dose is 15% of the skin entry dose in the AP projection and 9% in the PA projection. The air gap technique and its applications in reducing radiation doses to the gonads, breast and thyroid is described. A summary of dose reduction factors for these radiosensitive organs achieved by modified radiographic techniques in radiography of the chest, pelvis, spine and skull is given. (U.K.)

  20. Differentiated thyroid cancer treatment with therapeutic doses of 131I calculated by dosimetry: our experience

    International Nuclear Information System (INIS)

    Fadel, Ana M.; Chebel, G.M.; Valdivieso, C.M.; Degrossi, Osvaldo J.; Cabrejas, R.; Cabrejas, M.L.

    2006-01-01

    The optimum dose for the differentiated thyroid cancer treatment is a motive of controversy. There exist two ways of deciding the dose to administer: the empirical method (fixed doses) and dosimetric calculation method. The use of fixed doses has demonstrated safety and effectiveness. Nevertheless there are cases in which the use of several small doses not resolves the metastases illness of the patients. Using the Benua-Leeper method for dosimetric calculation we have evaluated the maximum dose treatment that could be administered to 20 patients who showed persistent disease after several treatments with 131 I. (author) [es

  1. Normal tissue tolerance to external beam radiation therapy: Thyroid; Dose de tolerance des tissus sains: la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Berges, O.; Giraud, P. [Service d' oncologie-radiotherapie, hopital europeen Georges-Pompidou, universite Paris Descartes, 75 - Paris (France); Belkacemi, Y. [Service d' oncologie-radiotherapie, CHU Henri-Mondor, universite Paris 12, 94 - Creteil (France)

    2010-07-15

    The thyroid is the most developed endocrine gland of the body. Due to its anatomical location, it may be exposed to ionizing radiation in external radiotherapy involving head and neck. This review aims to describe the thyroid radiation disorders, probably under-reported in the literature, their risk factors and follow-up procedures. The functional changes after external beam radiation consists mainly of late effects occurring beyond 6 months, and are represented by the clinical and subclinical hypothyroidism. Its incidence is approximately 20 to 30% and it can occur after more than 25 years after radiation exposure. Hyperthyroidism and auto-immune manifestations have been described in a lesser proportion. The morphological changes consist of benign lesions, primarily adenomas, and malignant lesions, the most feared and which incidence is 0.35%. The onset of hypothyroidism depends of the total dose delivered to the gland, and the irradiated. Modern techniques of conformal radiotherapy with modulated intensity could improve the preservation of the thyroid, at the expense of the increase in low doses and the theoretical risk of secondary cancers. (authors)

  2. Thyroid dose of I-131 absorbed by the internal organs of a pregnant woman

    International Nuclear Information System (INIS)

    Arcos P, A.; Manzanares A, E.; Vega C, H.R.; Leon, C.L. de

    2007-01-01

    The use of nuclear techniques, for diagnosis or treatment, generates stress in the patient and its relatives. During the pregnancy some sufferings related with the thyroid gland can be presented. If the patient is pregnant, OEP or NOEP, the stress comes from the fear to that the product can it turns affected. The dose is calculated that the Iodine 131, captured by the thyroid of a woman with three months of pregnancy, it deposits in the brain, stomach, heart, kidneys, liver, lungs, ovaries, pancreas, thymus, spleen and in the uterus. The thymus is the organ that receives the biggest dose. (Author)

  3. Dose selection for radioiodine therapy of borderline hyperthyroid patients according to thyroid uptake of 99mTc-pertechnetate: applicability to unifocal thyroid autonomy?

    International Nuclear Information System (INIS)

    Reinhardt, Michael J.; Joe, Alexius Y.; Biermann, Kim; Brockmann, Holger; Mallek, Dirk von; Ezziddin, Samer; Wissmeyer, Michael; Juengling, Freimut D.; Krause, Thomas M.

    2006-01-01

    The aim of this study was to evaluate the feasibility of applying a previously described dose strategy based on 99m Tc-pertechnetate thyroid uptake under thyrotropin suppression (TcTU s ) to radioiodine therapy for unifocal thyroid autonomy. A total of 425 consecutive patients (302 females, 123 males; age 63.1±10.3 years) with unifocal thyroid autonomy were treated at three different centres with 131 I, using Marinelli's formula for calculation of three different absorbed dose schedules: 100-300 Gy to the total thyroid volume according to the pre-treatment TcTU s (n=146), 300 Gy to the nodule volume (n=137) and 400 Gy to the nodule volume (n=142). Successful elimination of functional thyroid autonomy with either euthyroidism or hypothyroidism occurred at a mean of 12 months after radioiodine therapy in 94.5% of patients receiving 100-300 Gy to the thyroid volume, in 89.8% of patients receiving 300 Gy to the nodule volume and in 94.4% receiving 400 Gy to the nodule volume. Reduction in thyroid volume was highest for the 100-300 Gy per thyroid and 400 Gy per nodule strategies (36±19% and 38±20%, respectively) and significantly lower for the 300 Gy per nodule strategy (28±16%; p s can be used independently of the scintigraphic pattern of functional autonomous tissue in the thyroid. (orig.)

  4. TIRADS for sonographic assessment of hypofunctioning and indifferent thyroid nodules.

    Science.gov (United States)

    Schenke, Simone; Rink, T; Zimny, M

    2015-01-01

    To test the feasibility of the Thyroid Imaging Reporting And Data System (TIRADS) according to Horvath and Kwak for the assessment of thyroid nodules. Retrospective analysis of patients with thyroid nodules applying the following inclusion criteria: B-mode-ultrasound, surgery and histological results. Thyroid nodules were classified as TIRADS 2, 3, 4A, 4B, 4C, 5 and 6. A total of 172 patients were included (133 women, 48 ± 13 years, 39 men, 49 ± 11 years) with 222 thyroid nodules (24.9 ± 11.5 mm). Final histological diagnosis revealed 203 benign nodules (91%) and 19 malignant nodules (9%; 18 papillary thyroid carcinoma, PTC, and one medullary thyroid carcinoma, MTC). One hundred and sixty thyroid nodules were hypofunctioning in 99mTc-pertechnetate-scintigraphy, 14 nodules were hyperfunctioning and 46 nodules were classified as indifferent. In two cases with small carcinoma nodules (39%) were not clearly classifiable, including 3 carcinoma (4.1%). According to Kwak, the prevalence of malignancy was 6.9% in TIRADS 2, 0% in 3, 2% in 4A, 4.1% in 4B, 23.1% in 4C, and 100% in 5 and 6, respectively. Notably, in the subgroup of hot nodules, 11 (79%) were graded as TIRADS 4A or higher, and thus advisable for fine-needle aspiration biopsy in both TIRADS. The TIRADS described by Horvath is not practicable due to numerous unclassifiable nodules. The revised TIRADS published by Kwak is feasible and suitable to assess the prevalence of malignancy, but it cannot replace scintigraphic imaging. Fine-needle-biopsy is not necessary in nodules categorized as (K)TIRADS 3, 4A and 5.

  5. Reconstruction of individual doses for the subjects of a case-control study of thyroid cancer in French Polynesia

    International Nuclear Information System (INIS)

    Drozdovitch, V.; Cardis, E.; Doyon, F.; Vathaire, F. de; Bouville, A.

    2006-01-01

    A case-control study of thyroid cancer coordinated b y the Unit 605 I.N.S.E.R.M. as carried out in French Polynesia. Forty-six atmospheric nuclear weapons tests (including five safety tests) were conducted in French Polynesia between 966 and 1974. The study includes 600 subjects both cases and controls all aged up to 30 years old at start of nuclear weapons testing. Under the normal conditions following testing the radioactive debris was moved to the east from he test site (atolls Moruroa or Fangataufa) over the uninhabited regions of the Pacific. However, some of the radioactive debris in troposphere was caught in anticyclones eddies and were transferred back to the central South Pacific area in a few days. Radioactive clouds with changed direction result ed in the local deposition of radionuclides on the ground of inhabited islands of French Polynesia. Radiation doses to the thyroids of the subjects were assessed based on the available historical results of radiometric measurements and meteorological data. These included annual reports on the radiological situation in French Polynesia that had been sent to the Secretariat of UNSCEAR. Results of measurements of exposure rate and of total activity in filtered air were used to evaluate the ground depositions of specific radionuclides. Radiation monitoring also included measurements of 131 I and 137 Cs in cows milk produced in Tahiti and measurements of radioactivity in foodstuffs produced on the selected islands. For each atmospheric nuclear weapons test that contributed substantially to the local deposition of radionuclides, the radiation dose to the thyroid from 131 I intake via inhalation and ingestion was estimated. In additional, thyroid doses from the intake of short-lived radio iodines (132, 133, 135 I) and 132 Te, external exposure from gamma-emitted radionuclides deposited on the ground, and ingestion of long-lived 137 Cs were reconstructed. The assessment of individual thyroid doses took into account: (1

  6. Technique-dependent decrease in thyroid absorbed dose for dental radiography

    International Nuclear Information System (INIS)

    Wood, R.E.; Bristow, R.G.; Clark, G.M.; Nussbaum, C.; Taylor, K.W.

    1989-01-01

    A LiF thermoluminescent dosimetry (TLD) system, calibrated in the tissue of interest with the beam used for experimentation, was employed to investigate dosages (muGy) to the thyroid region of an anthropomorphic phantom resultant from two dental complete-mouth radiographic procedures. Both techniques were compared in terms of dosages associated with combinations of lead apron and thyroid collar shielding while using a 70-kVp or 90-kVp x-ray beam for a 20-film complete-mouth series. Lead shielding significantly decreased the dose to the thyroid using both techniques (p less than 0.05). The use of the 90-kVp beam resulted in a significant reduction in the thyroid absorbed dose when using the bisecting angle technique (p less than 0.05) but caused a significant increase in the thyroid absorbed dose when the paralleling technique was used (p less than 0.05). The implementation of higher kilovoltage techniques in dental offices must therefore be dependent on the radiographic technique employed

  7. Estimation of thyroid doses received by the population of Belarus as a result of the Chernobyl accident

    International Nuclear Information System (INIS)

    Gavrilin, Yu.; Khrouch, V.; Shinkarev, S.; Drozdovitch, V.; Minenko, V.; Shemyakina, E.; Bouville, A.; Anspaugh, L.

    1996-01-01

    Within weeks of the Chernobyl accident, about 300000 measurements of human thyroidal 131 I content were conducted in the more contaminated territories of the Republic of Belarus. Results of these and other measurements form the basis of thyroid-dose reconstruction for residents of Belarus. Preliminary estimates of thyroid doses have been divided into three classes. Class 1 ('measured' doses). Individual doses are estimated directly from the measured thyroidal 131 I content of the person considered, plus information on life style and dietary habits. Such estimates are available for about 130000 individuals from the contaminated areas of Gomel and Mogilev Region and Minsk city. Class 2 ('passport' doses). For every settlement with a sufficient number of residents with 'measured' doses, individual thyroid-dose distributions are determined for several age groups and levels of milk consumption. This action has been called the 'passportization' of the settlement. A population of about 2.7 million people resides in the 'passportized' settlements. Class 3 ('inferred' doses). For any settlement where the number of residents with 'measured' doses is small or equal to zero, individual thyroid doses are derived from the relationship obtained between the mean adult-thyroid dose and the deposition density of 131 I or 137 Cs in settlements with 'passport' doses presenting characteristics similar to those of the settlement considered. This method can be applied to the remainder of the population (about 7.3 million people). An approximate estimate of the collective thyroid dose for the residents of Belarus is presented. Illustrative results of individual thyroid dose and associated uncertainty are discussed for rural settlements and urban areas

  8. Estimation of foetal brain dose from I-131 in the foetal thyroid

    International Nuclear Information System (INIS)

    O'Hare, N.J.; Murphy, D.; Malone, J.F.; Gilligan, P.

    1997-01-01

    The ingestion of I-131 by pregnant women can have consequences for the developing foetus, in particular brain function. As the foetal thyroid accumulates iodine from the twelfth week of gestation onwards, the determination of foetal brain dose resulting from such I-131 accumulation is essential. Normal dosimetric methods fail to treat the case of the foetus. Using an approximation method based on the MIRD approach, a foetal dose estimation scheme is developed to allow the determination of foetal brain dose from foetal thyroid irradiation. Dose values are obtained for the foetus based on the maternal intake of I-131. It was found that the choice of biokinetic model for the mother/foetus has a large impact on the determined dose estimate. (author)

  9. Maximal safe dose therapy of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong Jin; Seok, Ju Won; Uh, Jae Sun

    2005-01-01

    In patients with recurrent or metastatic differentiated thyroid carcinoma, residual disease despite repetitive fixed dose I-131 therapy presents an awkward situation in terms of treatment decision making. Maximal safe dose (MSD) administration base on bone marrow radiation allows the delivery of a large amount I-131 to thyroid cancer tissue within the safety margin. We investigated the efficacy of MSD in differentiated thyroid cancers, which had persisted after conventional fixed dose therapy. Forty-six patients with differentiated thyroid carcinoma who had non-responsible residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. The postoperative pathology consisted of 43 papillary carcinomas and 3 follicular carcinomas. MSD was calculated according the Memorial Sloan Kettering Cancer Center protocol using blood samples. MSDs were administered at intervals of at least 6 months. Treatment responses were evaluated using I-131 whole body scan (WBS) and serum thyroglobulin measurements. Mean calculated MSD was 12.5±2.1 GBq. Of the 46 patients, 6 (13.0%) showed complete remission, 15 (32.6%) partial response, 19 (41.3%) stable disease, and 6 (13.0%) disease progression. Thus, about a half of the patients showed complete or partial remission, and of these patients, 14 (67%) showed response after a single MSD administration and 6 (29%) showed response after the second dose of MSD administrations. Twenty-nine patients (63%) experienced transient cytopenia after therapy, and recovered spontaneously with the exception of one. MSD administration is an effective method even in the patients who failed to be treated by conventional fixed dose therapy. MSD therapy of I-131 can be considered in the patients who failed by fixed dose therapy

  10. Chromosomal damage after Iodine-131 treatment for differentiated thyroid cancer: in vivo dose-effect relationship

    International Nuclear Information System (INIS)

    Nguyen, V.K.; Nguyen, X.P.; Truong, Q.X.

    2007-01-01

    Full text: Although it is well known that radiation induces chromosomal aberrations, there is a lack of information on the in- vivo dose-effect relationship in patients receiving Iodine-131 treatment and the results of previous studies are controversial. In this study, the dicentric chromosomal aberrations (DCA) analysis method was employed to investigate acute and late chromosomal damage (CD) in the peripheral lymphocytes of 58 differentiated thyroid cancer patients who received dose 1,1 GBq of Iodine-131 (group A), and 34 patients who received dose 3,7 GBq of Iodine- 131 (group B). The mean 100 metaphase spreads were scored for each subject. The DCA frequencies in cultured peripheral lymphocytes were determined before treatment to assess basal DCA frequencies, on the 3rd day to assess acute DCA frequencies and 6 months later to assess late DCA frequencies. The basal, acute and late DCA frequencies were divided into two groups: 0,18%, 2,14% and 0,53% (group A) and 0,18%, 2,12 % and 0,89% (group B), respectively, and these values differed significantly at various time after treatment (p 2 = 0,987), and group B as Y= 32,71 + 0,189 X. (r = 0,9381, R 2 = 0,880). However, there was an interesting difference in comparison with in- vitro studies, in that we found the coefficient β to have a negative value, suggesting the disappearance of damaged lymphocytes from peripheral circulation in a dose- dependent manner following Iodine-131 treatment. Further studies are therefore needed to clarify the effect of the negative β value on biological dosimetry approach in continuous internal low LET radiation, as in the case of Iodine-131 treatment. (author)

  11. Effect of radioiodine irradiation of thyroid gland in vitro with a dose of 4-5 Gy on iodide transport in thyrocytes

    International Nuclear Information System (INIS)

    Paster, Yi.P.

    2000-01-01

    We study the influence of ouabain on the basal and thyrotropin-stimulated iodide uptake in thyroid gland preliminarily irradiated by radioiodine (absorbed dose: 4-5 Gy) in vitro. Newborn pig thyroid tissue was incubated in a medium, containing 37 kBq/ml of 131-iodine (absorbed dose: 4-5 Gy), washed and achieved by collagenase dissociation. Thyrocytes were incubated with thyrotropin (100.0 mE/ml), ouabain (0.1 mol/l), and 125-iodide (0.4 kBq/ml). Then cells were washed, stored at 4 degree C for 60 days, and the 125-iodide uptake was assessed. Ouabain depressed both the basal and thyrotropin-stimulated iodide uptakes by thyrocytes in vitro. After preliminary radioiodine irradiation of the thyroid tissue (absorbed dose: 4-5 Gy), ouabain stimulated both the basal and thyrotropin-stimulated iodide uptakes by thyrocytes

  12. Efficiency of radioiodine therapy with a fix dose of I-131 in toxic thyroid adenoma

    International Nuclear Information System (INIS)

    Petrovski, Z

    2004-01-01

    Purpose: The aim of this study was to estimate the results obtained using a fix dose of I-131 in the treatment of the solitary toxic thyroid adenoma. Material and Methods: We have performed radioiodine therapy m 64 patients, 49 female (50+ 1 7 yrs) and 15 male (43+-15 yrs) with solitary toxic thyroid adenoma. 45 patients received fix dose I-131 of 850 MBq, while 19 patients were treated with calculated (MBq/gr) dose 555-1100 MBq Previously 39(64%) patients were clinically hyperthyreotic and received thyreostatic meditication which were interruptecf one week before the administration of I-131. Those patients who were euthyreotic, TSH was suppressed(<0.25 MU/m1). 61(95.3%) patients received a single dose, while 3(4, 7%) patients needed two doses. Resulting thyroid matabolism and volume of nodules were evaluated 6-48 months after treatment. Results: From 45 radioiodine treated patients with fix dose 6(9, 8%) became hypothyroidism, 36(85, 3%) euthyroidism and 3(4, 9%) recurrent hyperthyroidism, in comparison with 19 treated patients with calculated I-131 dose: 2(10, 5%) hypothyroidism, 16(84, 3%) euthyroidism and 1(5, 2%) recurrent hyperthyroidism. The size of the nodules became unpalpable m 17(26, 2%), decreased evidently in 33(52, 5%) and remained unchanged in 14(21, 3%) of the treated patients. Conclusion: A fix dose of I-131 is simple, safe and efficient in the treatment of solitary toxic thyroid adenoma. There was not significant different in incidence of late follow-up results of hypothyroidism and recurrent hyperthyroidism between fix dose and calculated MBq/gr dose. (authors)

  13. Methodology of thyroid dose reconstruction for population of Russia after the Chernobyl accident

    International Nuclear Information System (INIS)

    Zvonova, I.A.; Balonov, M.I.; Bratilova, A.A.; Vlasov, A.Ju; Pitkevich, V.A.; Vlasov, O.K.; Shishkanov, N.G.

    2000-01-01

    The Chernobyl accident has provoked radioactive contamination upon such extensive territories that the monitoring of short-lived iodine isotopes and estimation of their influence upon people were performed with a delay or not completely. So for solving the problem of dose estimation for thyroid exposure with iodine radionuclides among the population of contaminated territories, it was necessary to analyze retrospectively the existing data and to develop a model of the thyroid dose reconstruction. The reconstruction procedure for the average for a settlement thyroid dose in Russians has been worked out basing on the following data received in May-June 1986: 44 thousand measurements of I-131 content in the thyroid of inhabitants; 2000 gamma-spectrometric measurements of milk samples in Tula region; about 3500 measurements of total beta-activity in milk samples from Bryansk, Kaluga and Orel regions; over 100 radiochemical analysis of milk samples for I and Cs radionuclides' content; about 14000 thousand polls of inhabitants and local administration authorities upon the regime of behavior, milk consumption, cattle pasture dates and countermeasures in May 1986; the data of Roshydromet upon Cs-137 contamination of soil in settlements. The individual dose estimations by direct measurements of I-131 in the thyroid have been accepted as the basis for dose reconstruction. When counting the I-131 activity in the thyroid the additional radiation from cesium radionuclides distributed in extra-thyroidal tissues were excluded. Without this amendment the doses in the later terms of measurements could be 2-5 times overestimated. Because of the limited input data for dose calculations a formalized model of radioiodine intake into human body was used. The parameters of this model were based upon the analysis of the radiation monitoring data. According to the model daily intake of iodine-131 was constant within 10 days after radioactive fallout, and further on reduced proportionally

  14. Radiation risk assessment of the thyroid cancer in Ukrainian children exposed due to Chernobyl

    International Nuclear Information System (INIS)

    Sobolev, B.; Likhtarev, I.; Kairo, I.; Tronko, N.; Oleynik, V.; Bogdanova, T.

    1996-01-01

    The children's thyroid exposure to radioiodine is one of the most serious consequences of the Chernobyl accident. The collective dose to children aged 0-18 in the entire Ukraine was estimated to be 400000 person-Gy. The dose estimates were calculated on the basis of measurements of thyroid content of 131 I for about 108000 people in Ukraine aged 0-18 years in May-June 1986. Up to the end of 1994, 542 thyroid cancers throughout the Ukraine have been reported in children and young adults who were aged 0-18 at the time of the accident. Rates of thyroid cancer have climbed, from about 0.7 per million children aged 0-14 in 1986 to more 7 per million in 1994. Rates increased most in region closest to Pripyat'. Between 1990 and 1994, 9 of the 14,580 people who had been children at the time of the accident in Pripyat' developed thyroid cancer. This corresponds to an annual incidence of 123 cases per million persons. The estimated average thyroid dose in Ukrainian children varies by several orders of magnitude. There is a more than 30-fold gradient in thyroid cancer incidence rates corresponding to the gradient in thyroid doses from 131 I. A preliminary investigation shows an excess in the annual incidence rate of thyroid cancer, throughout the northern territory of Ukraine, corresponding to the average doses to thyroid from 131 I. Coefficients of regression of excess cancers versus thyroid dose have been calculated

  15. Thyroid hormone levels and hepatic enzyme activity in lactating dams after gestational exposure to low dose PBDE 47

    Energy Technology Data Exchange (ETDEWEB)

    Kuriyama, S.N.; Grande, S.W.; Akkoc, Z.; Souza, C.A.M. de; Chahoud, I. [Charite Univ. Medical School Berlin (Germany). Inst. of Clinical Pharmacology and Toxicology, Dept. Toxicology, Campus Benjamin Franklin; Fidalgo-Neto, A.A. [Oswaldo Cruz Foundation, Rio de Janeiro (Brazil). Lab. of Environmental Toxicology

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs), a class of widely used flame retardants, are found extensively in the environment (shown by several studies on sentinel animal species), as well as in humans. In rodents, technical commercial PBDE mixtures and individual congeners have shown to interfere with thyroid hormone homeostasis, produce a mix-type induction of hepatic microsomal enzymes, disrupt spontaneous behaviour, impair learning and memory and alter the cholinergic transmitter system. In rat and mice, some technical PBDE commercial mixtures such as DE-71 and Bromkal 70 and the congener PBDE 47 have shown to decrease circulating thyroid hormone levels. PBDEs are also able to induce both hepatic phase I and phase II detoxification enzymes, demonstrated by several investigations in laboratory animals. For example, induction of ethoxyresorufin-O-deethylase (EROD), pentoxyresorufin-Odespenthylase (PROD) and uridinediphospho-glucuronosyltransferase (UDPGT) has been shown in rodents and cell lines after exposure to technical mixtures or individual congeners. However, these studies deal with doses much higher than that found in human tissues, highlighting the importance of assessing the adverse effects of doses close to human exposure levels. PBDE 47 is the most predominant congener found in environmental and human samples (including human milk) and, therefore, hazard identification is extremely important for human risk assessment. We administered a single dose to gravid dams on gestation day 6 of either 140 {mu}g/kg BW or 700 {mu}g/kg BW of the congener, 2,2'4,4'-tetrabromo diphenyl ether (PBDE 47). These doses are pertinent to human exposure levels because a study by She et al. found a mean level of 33.3 {mu}g PBDE 47 /kg fat in human breast adipose tissue with a range from 7.01 to 196 {mu}g PBDE 47 /kg fat. In this study, thyroid hormone levels and hepatic enzyme activity were evaluated in lactating dams after in utero administration of low dose PBDE 47.

  16. Dose distribution in the thyroid and neighboring regions in therapy with 131I

    International Nuclear Information System (INIS)

    Monteiro, Rommel Barbosa; Bonifacio, Daniel Alexandre Baptista; Sa, Lidia Vasconcellos de

    2013-01-01

    In this work, simulations were performed with two types of computer simulators: the MIRD phantom and voxel phantom MASH, both of type adult male and in the standing position, coupled to the computational tool GATE (Geant4 Application for Tomographic Emission), to obtain the dose deposited in thyroid and neighboring regions

  17. Molecular alterations in childhood thyroid cancer after Chernobyl accident and low-dose radiation risk

    International Nuclear Information System (INIS)

    Suzuki, Keiji; Mitsutake, Norisato; Yamashita, Shunichi

    2012-01-01

    The linear no-threshold (LNT) model of radiation carcinogenesis has been used for evaluating the risk from radiation exposure. While the epidemiological studies have supported the LNT model at doses above 100 mGy, more uncertainties are still existed in the LNT model at low doses below 100 mGy. Thus, it is urged to clarify the molecular mechanisms underlying radiation carcinogenesis. After the Chernobyl accident in 1986, significant amount of childhood thyroid cancer has emerged in the children living in the contaminated area. As the incidence of sporadic childhood thyroid cancer is very low, it is quite evident that those cancer cases have been induced by radiation exposure caused mainly by the intake of contaminated foods, such as milk. Because genetic alterations in childhood thyroid cancers have extensively been studied, it should provide a unique chance to understand the molecular mechanisms of radiation carcinogenesis. In a current review, molecular signatures obtained from the molecular studies of childhood thyroid cancer after Chernobyl accident have been overviewed, and new roles of radiation exposure in thyroid carcinogenesis will be discussed. (author)

  18. Optimization of the therapeutic dose of 131I for thyroid differentiated carcinoma

    International Nuclear Information System (INIS)

    Lima, Fabiana Farias de

    2002-09-01

    I-131 thyroid cancer therapy is based on the strategy of concentrating radioactive iodine in the thyroid tissue, to completetly eliminate thyroid tissue and functioning thyroid cancer metastases remaining after thyroidectomy. In Brazil, fixed activities of 131 I generally are given, sometimes either delivering insufficient activities to ablate all of the remnants, or unnecessarily high activities, with patients remaining in the hospital for some period of time. This investigation proposes a protocol of individualized planning of ablative doses, based on individual patients metabolisms and measured thyroid remnant masses. Simulated thyroid remnants were fabricated in various forms, volumes and activities, and optimum image acquisition parameters were determined using Single-Photon Emission Computed Tomography 9SPECT). Resultant images were evaluated, to determine the apparent volumes and the 131 I concentrations. I-131 metabolism was studied in 9 patients who had undergone thyroidectomies. Their thyroid remnant masses were determined applying the same parameters used in SPECT simulation studies, and the optimum activity for their therapy was calculated and compared to the established fixed activity of 3.7 GBq (100 mCi), which would have normally been assigned. Background subtraction using the method of percent maximum counts, using a value of 67.5%, combined with scatter correction (triple energy window method), was shown to be optimum for SPECT quantification of volumes between 3-10 ml. Errors in the method were below 9% for sources with regular geometries and around 11% for sources with irregular geometries. In the patient studies, it was observed that 78% of patients could have received reduced activities of 131 (from 0.8-3-2. GBq (20-87 nCi). In addition, 33% of these patients could have received low enough activities to have discharged from the hospital, using an individualized administration scheme. This could also have resulted in a dose reduction for many

  19. Dose and risk evaluation to the thyroid gland in intra-oral dental radiology

    International Nuclear Information System (INIS)

    Souza, Edmilson M.; Lima, Marco A.F.; Kelecom, Alphonse; Correa, Samanda C.A.; Silva, Ademir X.; Brito, Alan

    2008-01-01

    Intra-oral technique is one of the most frequently used procedures of dental radiology, allowing the detection of a variety of dental anomalies such as caries, dental trauma and periodontal lesions, while exposing patients to relatively low doses of radiation. However, although the adverse effects of doses generated by dental radiology are essentially stochastic, a number of epidemiological studies have provided evidence of an increased risk of thyroid tumors for dental radiography. Many studies have measured doses of radiation for dental radiography, but only a few have estimated thyroid dose. Furthermore, most of the studies on dose evaluation in dental radiology are based on standardized calculation phantoms, which neglect the variance of the patient size or even sex. The purpose of this study is to use the Monte Carlo code MCNPX and the FAX (Female Adult voXel) and MAX (Male Adult voXel) phantoms to investigate how absorbed doses to the thyroid gland in intraoral dental examinations vary in female and male patients. The lifetime cancer incidence attributable to dental examinations were estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The phantoms study proved a useful trial for detecting the radiation dose to the thyroid gland and conclusively supported that the anatomy may be regarded as an influencing factor in radiation dose received during dental examination. Finally, the results have also confirmed that the association of the MCNPX code and the MAX and FAX phantoms is very useful in dosimetric studies on radiographic examinations of female and male patients. (author)

  20. Derivation of the critical effect size/benchmark response for the dose-response analysis of the uptake of radioactive iodine in the human thyroid.

    Science.gov (United States)

    Weterings, Peter J J M; Loftus, Christine; Lewandowski, Thomas A

    2016-08-22

    Potential adverse effects of chemical substances on thyroid function are usually examined by measuring serum levels of thyroid-related hormones. Instead, recent risk assessments for thyroid-active chemicals have focussed on iodine uptake inhibition, an upstream event that by itself is not necessarily adverse. Establishing the extent of uptake inhibition that can be considered de minimis, the chosen benchmark response (BMR), is therefore critical. The BMR values selected by two international advisory bodies were 5% and 50%, a difference that had correspondingly large impacts on the estimated risks and health-based guidance values that were established. Potential treatment-related inhibition of thyroidal iodine uptake is usually determined by comparing thyroidal uptake of radioactive iodine (RAIU) during treatment with a single pre-treatment RAIU value. In the present study it is demonstrated that the physiological intra-individual variation in iodine uptake is much larger than 5%. Consequently, in-treatment RAIU values, expressed as a percentage of the pre-treatment value, have an inherent variation, that needs to be considered when conducting dose-response analyses. Based on statistical and biological considerations, a BMR of 20% is proposed for benchmark dose analysis of human thyroidal iodine uptake data, to take the inherent variation in relative RAIU data into account. Implications for the tolerated daily intakes for perchlorate and chlorate, recently established by the European Food Safety Authority (EFSA), are discussed. Copyright © 2016 The Author(s). Published by Elsevier Ireland Ltd.. All rights reserved.

  1. Ultrasound-Detected Thyroid Nodule Prevalence and Radiation Dose from Fallout

    Science.gov (United States)

    Land, C. E.; Zhumadilov, Z.; Gusev, B. I.; Hartshorne, M. H.; Wiest, P. W.; Woodward, P. W.; Crooks, L. A.; Luckyanov, N. K.; Fillmore, C. M.; Carr, Z.; Abisheva, G.; Beck, H. L.; Bouville, A.; Langer, J.; Weinstock, R.; Gordeev, K. I.; Shinkarev, S.; Simon, S. L.

    2014-01-01

    Settlements near the Semipalatinsk Test Site (SNTS) in northeastern Kazakhstan were exposed to radioactive fallout during 1949–1962. Thyroid disease prevalence among 2994 residents of eight villages was ascertained by ultrasound screening. Malignancy was determined by cytopathology. Individual thyroid doses from external and internal radiation sources were reconstructed from fallout deposition patterns, residential histories and diet, including childhood milk consumption. Point estimates of individual external and internal dose averaged 0.04 Gy (range 0–0.65) and 0.31 Gy (0–9.6), respectively, with a Pearson correlation coefficient of 0.46. Ultrasound-detected thyroid nodule prevalence was 18% and 39% among males and females, respectively. It was significantly and independently associated with both external and internal dose, the main study finding. The estimated relative biological effectiveness of internal compared to external radiation dose was 0.33, with 95% confidence bounds of 0.09–3.11. Prevalence of papillary cancer was 0.9% and was not significantly associated with radiation dose. In terms of excess relative risk per unit dose, our dose–response findings for nodule prevalence are comparable to those from populations exposed to medical X rays and to acute radiation from the Hiroshima and Nagasaki atomic bombings. PMID:18363427

  2. Measurement of the thyroid's iodine absorption utilizing minimal /sup 131/I dose

    Energy Technology Data Exchange (ETDEWEB)

    Paz A, B.; Villegas A, J.; Delgado B, C. (Universidad Nacional San Agustin de Arequipa (Peru). Departamento de Bioquimica)

    1981-03-01

    We utilize a minimal dose of /sup 131/I thus limiting the contact of the thyroid tissues with the isotopic materials to determine the absorption of /sup 131/I by the thyroid from 6 to 24 hours in 90 pupils of the locality of Arequipa. The average rate of absorption in 6 and 24 hours in the case considered are of 24.15% and 35.42% respectively, with a standard deviation of 6.93% and 9.61%. No significant differences were reported from the results of those of adults and our own results in all the probes which were undertaken.

  3. Consultative exercise on dose assessments.

    Science.gov (United States)

    Bridges, B A; Parker, T; Simmonds, J R; Sumner, D

    2001-06-01

    A summary is given of a meeting held at Sussex University, UK, in October 2000, which allowed the exchange of ideas on methods of assessment of dose to the public arising from potential authorised radioactive discharges from nuclear sites in the UK. Representatives of groups with an interest in dose assessments were invited, and hence the meeting was called the Consultative Exercise on Dose Assessments (CEDA). Although initiated and funded by the Food Standards Agency, its organisation, and the writing of the report, were overseen by an independent Chairman and Steering Group. The report contains recommendations for improvement in co-ordination between different agencies involved in assessments, on method development and on the presentation of data on assessments. These have been prepared by the Steering Group, and will be taken forward by the Food Standards Agency and other agencies in the UK. The recommendations are included in this memorandum.

  4. Thyroid cancer incidence among Swedish patients exposed to diagnostic doses of iodine-131: A preliminary report

    International Nuclear Information System (INIS)

    Hall, P.E.

    1996-01-01

    The level of risk associated with I-131 is not well defined but appears lower than equivalent doses of x-rays. To provide quantitative data on the risk of thyroid cancer following I-131 exposure, 34,104 patients surviving ≅ 5 years after I-131 administration between 1950-69 for diagnostic purposes were studied. The mean thyroid dose was estimated to be 1.1 Gy (range 0-40.5). A significantly increased risk of a subsequent thyroid cancer was found, however, the excess rates were based entirely on patients referred because of a suspicion of a thyroid tumor. There was no suggestion of an increasing risk with increasing dose or time since exposure. No significant excess risk was found among those less than 20 years of age at exposure. The absence of a risk among those over age 20 is consistent with studies of A-bomb survivors and implies that any type of exposure to ionizing radiation later in life is associated with a minimal cancer risk. (author). 23 refs, 4 tabs

  5. Thyroid cancer incidence among Swedish patients exposed to diagnostic doses of iodine-131: A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Hall, P E [Karolinska Hospital, Stockhom (Sweden). Dept. of General Oncology; Holm, L E [National Inst. of Public Health, Stockholm (Sweden)

    1996-08-01

    The level of risk associated with I-131 is not well defined but appears lower than equivalent doses of x-rays. To provide quantitative data on the risk of thyroid cancer following I-131 exposure, 34,104 patients surviving {approx_equal} 5 years after I-131 administration between 1950-69 for diagnostic purposes were studied. The mean thyroid dose was estimated to be 1.1 Gy (range 0-40.5). A significantly increased risk of a subsequent thyroid cancer was found, however, the excess rates were based entirely on patients referred because of a suspicion of a thyroid tumor. There was no suggestion of an increasing risk with increasing dose or time since exposure. No significant excess risk was found among those less than 20 years of age at exposure. The absence of a risk among those over age 20 is consistent with studies of A-bomb survivors and implies that any type of exposure to ionizing radiation later in life is associated with a minimal cancer risk. (author). 23 refs, 4 tabs.

  6. Assessment of lipid metabolism in thyroid dysfunction

    Directory of Open Access Journals (Sweden)

    V. G. Kadzharyan

    2014-02-01

    Full Text Available 1. Actuality According to WHO Thyroid dysfunction is one of the most prevalent in humans and is one of the risk factors of cardiovascular diseases. Hypothyroidism affects the mechanisms of potentiation of cardiovascular risk factors, suggesting the need to study the level of the blood lipids in all patients with thyroid dysfunction. 2. The purpose of this study. To define features of lipid metabolism, depending on the functional state of the thyroid gland. 3. Material and methods. The study included 95 patients, mean age was 49,8 ± 12,9 years. 74 of them were women (78% and 21 - men (22%. In accordance with the purpose of the work 3 groups of subjects were formed. I-st group - 35 patients with hypothyroidism, mean age 52,5 ± 10,3 years, II-nd group - 37 patients with hyperthyroidism, the average age was 45,1 ± 13 years, III (control group - 23 patients with euthyroid, mean age 53,9 ± 14,8 years. Levels of TSH, triiodothyronine, thyroxine, microsomal antibodies to thyroglobulin and thyroid peroxidase were evaluated for total and biochemical analysis. To determine the type of hyperlipoproteinemia Fredrickson, 1967 recommendations were used. 4. Results of the study Lipid profile parameters in the I-st group compared with the control were even higher. Cholesterol increased up to 6,9% (p <0,005, Tg - 8,6% (p <0,005, β -DP - 6,8% (p <0,5, in comparison with the II-nd: cholesterol - 56% (p <0,005, TG - 55% (p <0,005 and β-PL 44% (p <0.5. In group II rates were lower than in the III- cholesterol - 8% (p <0,005, Tg 8,3% (p <0,005 and β-PL 6,5% (p <0,5. Patients from the I-st group had the following distribution of hyperlipidemia (Fredrickson, 1967.: I type - 10 patients (29%; IIb type - 15 subjects (43%; IIa type - 9 subjects (26%; IV type - 1 patient (2%. The correlation dependence of TSH and cholesterol (r = +0,37, p <0,05, TG (r = +0,25, p <0,05, β-PL (r = +0,74, p <0.05, TG AT (r = +0,55, p <0,05, the level of bilirubin (r = +0,29, p <0

  7. Thyroid nodules in the population living around semipalatinsk nuclear test site. Possible implications for dose-response relationships study

    International Nuclear Information System (INIS)

    Zhumadilov, Z.

    2006-01-01

    The risk of radiation-induced nodules is higher than the risk for radiation-induced cancer. Risk factors and specific modifiers of the dose-response relationship may vary among different populations and not be well recognized. Many thyroid studies have considered thyroid nodularity itself, but not specific morphological types of thyroid nodules. There are many specific types of thyroid nodules which follow a morphological classification of thyroid lesions, including some congenital and tumor-like conditions. Modern equipment and technique can help us to identify particular specific types of thyroid nodules. In this study we report some results of a clinically applicable approach to materials derived from three studies. From 1999 through 2002, we have screened 571 current residents from 4 exposed and 1 control village near the Semipalatinsk Nuclear Test Site area, who were of similar ages (<20) at the time of major radiation fallout events at the Semipalatinsk Nuclear Test Site (SNTS). Prevalent nodules were identified by ultrasound and fine-needle aspiration biopsy, cytopathology results. Analysis of ultrasound images and cytopathology of thyroid lesions among exposed and non-exposed population allowed us to distinguish some interesting ultrasound features for specific types of thyroid nodules. We believe that it would be interesting and possibly more informative for thyroid dosimetry studies to consider specific morphological types of thyroid nodules. We need more detailed research to clarify the feasibility of applying these findings for study of the dose-response relationship. (author)

  8. Cytogenetic biodosimetry and dose-rate effect after radioiodine therapy for thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Khvostunov, Igor K. [Russian Ministry of Health Care, A.F. Tsyb Medical Radiological Research Center, Branch of the National Medical Research Radiological Centre, Obninsk, Kaluga Region (Russian Federation); Nagasaki University, Department of Radiation Molecular Epidemiology, Atomic Bomb Disease Institute, Nagasaki (Japan); Saenko, Vladimir A.; Yamashita, Shunichi [Nagasaki University, Department of Radiation Molecular Epidemiology, Atomic Bomb Disease Institute, Nagasaki (Japan); Krylov, Valeri; Rodichev, Andrei [Russian Ministry of Health Care, A.F. Tsyb Medical Radiological Research Center, Branch of the National Medical Research Radiological Centre, Obninsk, Kaluga Region (Russian Federation)

    2017-08-15

    This study set out to investigate chromosomal damage in peripheral blood lymphocytes of thyroid cancer patients receiving {sup 131}I for thyroid remnant ablation or treatment of metastatic disease. The observed chromosomal damage was further converted to the estimates of whole-body dose to project the adverse side effects. Chromosomal aberration analysis was performed in 24 patients treated for the first time or after multiple courses. Blood samples were collected before treatment and 3 or 4 days after administration of 2-4 GBq of {sup 131}I. Both conventional cytogenetic and chromosome 2, 4 and 12 painting assays were used. To account for dose-rate effect, a dose-protraction factor was applied to calculate the whole-body dose. The mean dose was 0.62 Gy (95% CI: 0.44-0.77 Gy) in the subgroup of patients treated one time and 0.67 Gy (95% CI: 0.03-1.00 Gy) in re-treated patients. These dose estimates are about 1.7-fold higher than those disregarding the effect of exposure duration. In re-treated patients, the neglected dose-rate effect can result in underestimation of the cumulative whole-body dose by the factor ranging from 2.6 to 6.8. Elevated frequency of chromosomal aberrations observed in re-treated patients before radioiodine therapy allows estimation of a cumulative dose received from all previous treatments. (orig.)

  9. Dose selection for radioiodine therapy of borderline hyperthyroid patients according to thyroid uptake of {sup 99m}Tc-pertechnetate: applicability to unifocal thyroid autonomy?

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Michael J.; Joe, Alexius Y. [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); University Hospital Freiburg, Department of Nuclear Medicine, Hugstetter Str. 55, 79106 Freiburg (Germany); Biermann, Kim; Brockmann, Holger; Mallek, Dirk von; Ezziddin, Samer [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); Wissmeyer, Michael [Inselspital Bern, Department of Nuclear Medicine, 3010 Bern (Switzerland); Juengling, Freimut D.; Krause, Thomas M. [University Hospital Freiburg, Department of Nuclear Medicine, Hugstetter Str. 55, 79106 Freiburg (Germany); Inselspital Bern, Department of Nuclear Medicine, 3010 Bern (Switzerland)

    2006-05-15

    The aim of this study was to evaluate the feasibility of applying a previously described dose strategy based on {sup 99m}Tc-pertechnetate thyroid uptake under thyrotropin suppression (TcTU{sub s}) to radioiodine therapy for unifocal thyroid autonomy. A total of 425 consecutive patients (302 females, 123 males; age 63.1{+-}10.3 years) with unifocal thyroid autonomy were treated at three different centres with {sup 131}I, using Marinelli's formula for calculation of three different absorbed dose schedules: 100-300 Gy to the total thyroid volume according to the pre-treatment TcTU{sub s} (n=146), 300 Gy to the nodule volume (n=137) and 400 Gy to the nodule volume (n=142). Successful elimination of functional thyroid autonomy with either euthyroidism or hypothyroidism occurred at a mean of 12 months after radioiodine therapy in 94.5% of patients receiving 100-300 Gy to the thyroid volume, in 89.8% of patients receiving 300 Gy to the nodule volume and in 94.4% receiving 400 Gy to the nodule volume. Reduction in thyroid volume was highest for the 100-300 Gy per thyroid and 400 Gy per nodule strategies (36{+-}19% and 38{+-}20%, respectively) and significantly lower for the 300 Gy per nodule strategy (28{+-}16%; p<0.01). A dose strategy based on the TcTU{sub s} can be used independently of the scintigraphic pattern of functional autonomous tissue in the thyroid. (orig.)

  10. Radiotherapy in differentiated thyroid cancer: Optimal dose distribution using a wax bolus

    International Nuclear Information System (INIS)

    Mayer, R.; Stucklschweiger, G.; Oechs, A.; Pakish, B.; Hackl, A.; Preidler, K.; Szola, D.

    1994-01-01

    The study includes 53 patients with differentiated thyroid cancer, who underwent surgical and radioiodine therapy as well as hormone therapy. Postoperative radiotherapy was performed in all patients in 'mini-mantle-technique' with parallel opposed fields, followed by an anterior boost-field with electrons up to 60-64 Gy, using a wax bolus for optimal dose distribution in the target volume sparing out the spinal cord as much as possible. The dose to the spinal cord did not exceed 44 Gy in any case. The study shows that radiotherapy with doses up to 60-64 Gy plays an important role in postsurgical therapeutic management. Therefore nonradical surgery is a less important prognostic factor for survival and local recurrence in patients with differentiated thyroid cancer than histological diagnosis in combination with age and lymph node involvement

  11. Study of the dose to the thyroid and the eye in computed tomography of the brain

    International Nuclear Information System (INIS)

    Raeside, D.E.; Anderson, D.W.; Galloway, D.C.

    1978-01-01

    Thermoluminescent doimeters were used to estimate the dose to the thyroid and the eye for routine clinical computer tomography of the brain using an EMI CT 5005 scanner (20-sec data acquisition mode, bolus covering the head). The data can be summarized by the linear relations D/sub t/ = (7.5 +- 0.8)N millirads (8 less than or equal to N less than or equal to 18) and D/sub e/ = (39 +- 5)N + (1400 +- 200)n millirads (8 less than or equal to N less than or equal to 20,0 less than or equal to n less than or equal to 6) where D/sub t/ is the dose to the tissue anterior to the thyroid, D/sub e/ is the dose to the anterior tissue of the eyelid, N is the total number of DT cuts, and n is the number of cuts in which the globe of the eye is imaged

  12. The results of the radioiodine-therapy of benign thyroid diseases respecting the applied radiation dose

    International Nuclear Information System (INIS)

    Maier, C.

    1994-09-01

    452 patients with benign thyroid diseases had been explored after 6 weeks, 6 months, 1 year, 5 years and 10 years after undergone radioiodine treatment retrospectively with regard to the applied radiation dose. A relevant relation between the radiation dose and the rate of hypothyroidism could only be proved as a tendency. Treating hyperthyroidism with radioiodine, the rates of hypothyroidism after therapy were not caused by significantly higher radiation doses. Therefore suggestions to change the used radiation-doses basically cannot be made. The applied doses of radiation are sufficient to achieve a rather satisfactory effect in healing hyperthyroidism. Cases of malignancy after radioiodine therapy could not be found in this population. The effective half-life determination before therapy can be neglected, because there was found a significant difference between the pre-therapeutically estimated half-life and the post-therapeutically measured effective half-life of radioiodine. Instead, fixed values of effective half-life should be used for each group of benign thyroid diseases. The radiation therapy still seems to be an efficient treatment to cure benign thyroid diseases with rare side effects. It also can be applied to patients below the age of 40. Generally it is an alternative to drug-therapy or surgery, always considering the individual relation between gain and risk. In this respect good results can be obtained and a relapse of hyperthyroidism is hardly to expect. (author)

  13. Radiation absorbed dose and expected risk in head and neck tissues after thyroid radioiodine therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, A [National Center for Nuclear and Radiation Control, AEA., Cairo (Egypt); Farag, H I [National Cancer instiute, Cairo University, Cairo (Egypt); Saleh, A [Al-hussien Hospital, Al-Azhar University, Cairo (Egypt)

    1997-12-31

    Measurement of absorbed dose in head and neck phantom after applying I-131 therapeutic dose for the treatment of thyroid malignancies was conducted. The measurement were carried out at several sites of phantom using TL dosimeters. The absorbed doses were also measured on the skin of four patients during their administration of I-131 therapeutic doses 1.332 GBq (36 mci) I-131. The measurements were taken over 69 hours exposure at different sites of phantom. The same measurements were carried out on the four patients. At five sites of the patients head and neck, the absorbed dose were measured and compared with that measured on the phantom. The values measured are discussed in the light of the published individual absorbed doses in the organs by ICRP tables. High absorbed doses were absorbed in the different sites of the head and neck during the I-131 therapy (0.14-9.68 mGy/mCi). 3 figs., 2 tabs.

  14. Is visual assessment of thyroid attenuation on unenhanced CT of the chest useful for detecting hypothyroidism?

    Science.gov (United States)

    Maldjian, P D; Chen, T

    2016-11-01

    To determine if visual assessment of the attenuation of morphologically normal appearing thyroid glands on unenhanced computed tomography (CT) of the chest is useful for identifying patients with decreased thyroid function. This was a retrospective study of 765 patients who underwent both unenhanced CT of the chest and thyroid function tests performed within 1 year of the CT examination. Attenuation of the thyroid gland was visually assessed in each patient relative to the attenuation of the surrounding muscles to categorise the gland as "low attenuation" (attenuation similar to surrounding muscles) or "high attenuation" (attenuation greater than surrounding muscles). Thyroid attenuation was quantitatively measured in each case to determine the validity of the visual assessment. Results of thyroid function tests were used to classify thyroid function as hypothyroid, euthyroid, or hyperthyroid. Data were analysed to determine the relationship between visual assessment of thyroid attenuation and status of thyroid function. Thyroid glands of low attenuation were present in 4.2% (32/765) of the patients. Nearly half (47%) of the patients with low-attenuation thyroids had hypofunctioning thyroid glands. Compared to patients with high-attenuation thyroids, patients with low-attenuation thyroids were significantly more likely to have decreased thyroid function (clinical and subclinical hypothyroidism) and significantly less likely to be euthyroid (p<0.0001). Quantitative measurement of thyroid attenuation confirmed the validity of the visual assessment. Low attenuation of an otherwise normal-appearing thyroid gland on unenhanced CT of the chest is strongly associated with decreased thyroid function. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. I-131 therapy for thyroid diseases: Doses, new regulations and patient advice

    International Nuclear Information System (INIS)

    Amaral, H.; Michaud, P.

    2001-01-01

    I-131 therapy has been widely used in the past 50 years. Its main applications are hyperthyroidism and functioning thyroid cancer. The indications, doses, regulations, precautions and guidelines differ in various centers. The following are recommended: 1. I-131 should be indicated in agreement of the endocrinologist and the nuclear physician with the patient consent; 2. Pre-treatment I-131 thyroid uptake must be performed; 3. The only contraindication for treatment is pregnancy, in children it might be used with caution; 4. For thyrotoxicosis both a calculated or an ablative dose (555 MBq) criteria are acceptable In this case secondary hypothyroidism must be considered an objective rather than a complication; 5. In uninodular toxic goiter a 1110 MBq dose is recommended; 6. Iodine free diet is indicated only for cancer patients; 7. Propylthiouracil (PTU) must be discontinued 5 days before treatment, it should be reinitiated 5 days later; 8. Prophylactic use of corticoid in Graves' disease still require more clinical data to support its use; 9. In treatment failure, wait six months for a new dose; 10. In intrathyroid cancer disease an ablative dose of 3700 MBq should be administered 4 weeks post-thyroidectomy or with a TSH level above 30 μUI/mL; 11. A whole body scan should be done one week later; 12. Follow-up whole body scan should be used only if there is clinical suspicion of metastasis. Thyroid hormone replacement must be discontinued for 30 days or with TSH value above 30 I/mL. For follow-up scan 185 MBq of I-131 are recommended to ovoid thyroid tissue stunning; 13. For metastases, 5700 to 7400 MBq dose is recommended if there are cervical lymphatic nodes or distant metastases. We recommended to adopt the criteria proposed by the United States Nuclear Regulatory Commission (NRC) published as 10 CFR 35.75 and the Regulatory Guide 8.39 for patients release after I-131 administration. (author)

  16. Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Sic; Park, Ju Kyeong; Lee, Seung Hun; Kim, Yang Su; Lee, Sun Young; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2014-12-15

    To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11-30% reduction effect and the surface dose of thyroid showed 20-48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

  17. Maximal safe dose of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong-Jin; Chung, June-Key; Kim, Sung-Eun; Kang, Won-Jun; Park, Do-Joon; Lee, Dong-Soo; Cho, Bo-Youn; Lee, Myung-Chul

    2008-01-01

    The maximal safe dose (MSD) on the basis of bone marrow irradiation levels allows the delivery of a large amount of I-131 to thyroid cancer tissue. The efficacy of MSD therapy in differentiated metastatic thyroid cancers that persisted after conventional fixed dose therapy is investigated. Forty-seven differentiated thyroid carcinoma patients with non-responsive residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. Their postoperative pathologies were 43 papillary carcinomas and 4 follicular carcinomas. The MSD was calculated with the Memorial Sloan-Kettering Cancer Center protocol using serial blood samples. The MSDs were administered at intervals of 6 months. Treatment responses were evaluated using I-131 whole-body scans and serum thyroglobulin measurements. The mean calculated MSD was 12.5±2.1 GBq (339.6±57.5 mCi). Of the 46 patients, 7 (14.9%) showed complete remission, 15 (31.9%) partial remission, 19 (40.4%) stable disease, and 6 (12.8%) disease progression. Of the patients who showed complete or partial remission, 15 (65%) showed response after the first MSD session and 6 (26%) showed response after the second session. Twenty-nine patients (62%) experienced transient cytopenia after therapy, but three did not recover to the baseline level. The maximal safe dose provides an effective means of treatment in patients who failed to respond adequately to conventional fixed dose therapy. I-131 MSD therapy can be considered in patients who fail fixed dose therapy. (author)

  18. Role of ultrasound in the assessment of nodular thyroid disease

    International Nuclear Information System (INIS)

    Bastin, S.; Bolland, M. J.; Croxson, M. S.

    2009-01-01

    Full text: The role for ultrasound (US) in the assessment of nodular thyroid disease has increased in recent years. This expanded role has been highlighted in recent consensus guidelines on the management of nodular thyroid disease. In this review, we address the potential roles for US in assessing thyroid nodules and review these recent guidelines. In particular, we review the evidence that US characteristics of thyroid nodules can predict the risk of malignancy. A predominantly solid nodule, hypoechogenicity, microcalcification, macrocalcification, ill-defined margins, intranodular vascularity, and taller-than-wide shape have all been associated with increased risk of malignancy, but no single US characteristic is sufficiently sensitive or specific to exclude or diagnose malignancy by itself. However, the use of combinations of US characteristics to stratify nodules into high and low risk for malignancy appears a promising strategy. Unselected nodules without any suspicious US features have a low risk of malignancy (<2%), whereas malignancy rates are much higher in nodules with at least two suspicious features. Recent guidelines endorse this approach of using combinations of US features to guide nodule selection for fine needle aspiration.

  19. The Effect of High Dose Radioiodine Therapy on Formation of Radiation Retinopathy During Thyroid Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Tülay Kaçar Güvel

    2014-10-01

    Full Text Available Objective: Non-thyroidal complication of high-dose radioiodine therapy for thyroid carcinoma might cause salivary and lacrimal gland dysfunction, which may be transient or permanent in a dose-dependent manner. However, radiation retinopathy complicating 131I therapy, has not been previously well characterized. The aim of this study was to evaluate the extent of retinal damage among patients who had received high doses of radioiodine treatment. Methods: Forty eyes of 20 patients (3 male, 17 female who received 250-1000 mCi during 131I therapy and on ophthalmological follow up for a year after the last treatment were included in the study. Mean age of the study group was 50 years (range 25-70 years. In ophthalmologic examination, visual acuity was measured in order to determine visual loss. Intraocular pressure was measured in all the patients. Then lens examination was carried out with slit lamp biomicroscopy in order to investigate cataract or partial lens opacities. Fundus observation was carried out through the dilated pupil with slit lamp biomicroscopy using 90 D noncontact lens. Result: The best corrected visual aquity with Snellen chart was found as 1.0 in 36 eyes (90% and between 0.6 and 0.9 (10% in 4 eyes (10%. At the biomicroscopic fundus examination, retinal hemorrhage consistent with radiation retinopathy, microaneurysm, microinfarction, edema or exudation, vitreus hemorrhage, partial or total optical disc pallor indicating papillopathy in the optic disc were not observed in any of the eyes. Conclusion: This result indicates that there is not any significant correlation between repeated high-dose radioiodine therapy and radiation retinopathy in differentiated thyroid carcinomas. Even though there is not a significant restriction in use of higher doses of radioiodine therapy in differentiated thyroid carcinoma, more extensive studies are needed in order to obtain more accurate data on possible occurrence of retinopathy.

  20. Radiation dose to family members of hyperthyroidism and thyroid cancer patients treated with 131I

    International Nuclear Information System (INIS)

    Pant, G. S.; Sharma, S. K.; Bal, C. S.; Kumar, R.; Rath, G. K.

    2006-01-01

    The thermoluminescence dosemeter (TLD) was used for measuring radiation dose to family members of thyrotoxicosis and thyroid cancer patients treated with 131 I using CaSO 4 :Dy discs. There were 45 family members of thyrotoxicosis patients, who were divided into two groups with 22 in the first and 23 in the second group. Radiation safety instructions were the same for both the groups except in the second group where the patients were advised to use a separate bed at home for the first 3 d of dose administration. An activity ranging from 185 to 500 MBq was administered to these patients. The whole-body dose to family members ranged from 0.4 to 2.4 mSv (mean 1.1 mSv) in the first group and 0-1.9 mSv (mean 0.6 mSv) in the second group. A total of 297 family members of thyroid cancer patients were studied for whole-body dose estimation. An activity ranging from 0.925 to 7.4 GBq was administered to the thyroid cancer patients. The family members were divided into three groups depending upon the mode of transport and facilities available at home to avoid close proximity with the patient. Group A with 25 family members received a dose ranging from 0 to 0.9 mSv (mean 0.4 mSv), group B with 96 family members received a dose ranging from 0 to 8.5 mSv (mean 0.8 mSv) and group C with 176 family members received a dose ranging from 0 to 5.0 mSv (mean 0.8 mSv). The thyroid monitoring was also done in 103 family members who attended the patients in isolation wards for >2 d. Thyroid dose in them ranged from 0 to 2.5 mGy (mean 0.1 mGy). (authors)

  1. Reevaluation of the Thyroid Scan for the Assessment of Pathophysiologic Status of Thyroid Disease

    International Nuclear Information System (INIS)

    Woo, In Sook; Nah, Jung Il; Kim, Deog Yoon

    1991-01-01

    To diagnosis and understand the pathophysiologic status of thyroid disease, not only hormonal measurements but also thyroid scan is believed to have a unique role. Especially in the cases of the change of the thyroid function by thyroiditis, it is emphasized that thyroid scan can be helpful in differential diagnosis, Discordant results of thyroid hormone levels and thyroid scan are found in transient hyperthyroidism, or in transient hypothyroidism. We analysed and reevaluated thyroid scan to look at the importance of thyroid scan. The results are summarised as follows: 1) 80%. of hyperthyroid patients had hyperthyroidism increased RAIU with even density, they are compatible with Graves' disease. 2) 2.1% of hyperthyroid patients had normal or decreased RAIU, which are classified as high iodine turn over genuine hyperthyroidism. 3) 8.5% of hyperthyroid patients had markedly decreased RAIU at both 2 hour and 24 hour, whose pathologic processes are suggested to be heterogenous namely subacute thyroiditis, postpartum thyroiditis, Hashimoto's thyroiditis, and pamless thyroiditis. 4) 45% of hypothyroid patients had increased 24 hr RAIU, 30% of hypothyroid patients were normal, 25%, decreased. In conclusion, thyroid scan should be reevaluated its useful role to asses the pathophysiologic status of thyroid disease. Especially in cases of transient thyrotoxicosis, thyroid scan is essential to diagnose and follow up the disease process.

  2. Reevaluation of the Thyroid Scan for the Assessment of Pathophysiologic Status of Thyroid Disease

    Energy Technology Data Exchange (ETDEWEB)

    Woo, In Sook; Nah, Jung Il; Kim, Deog Yoon [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1991-03-15

    To diagnosis and understand the pathophysiologic status of thyroid disease, not only hormonal measurements but also thyroid scan is believed to have a unique role. Especially in the cases of the change of the thyroid function by thyroiditis, it is emphasized that thyroid scan can be helpful in differential diagnosis, Discordant results of thyroid hormone levels and thyroid scan are found in transient hyperthyroidism, or in transient hypothyroidism. We analysed and reevaluated thyroid scan to look at the importance of thyroid scan. The results are summarised as follows: 1) 80%. of hyperthyroid patients had hyperthyroidism increased RAIU with even density, they are compatible with Graves' disease. 2) 2.1% of hyperthyroid patients had normal or decreased RAIU, which are classified as high iodine turn over genuine hyperthyroidism. 3) 8.5% of hyperthyroid patients had markedly decreased RAIU at both 2 hour and 24 hour, whose pathologic processes are suggested to be heterogenous namely subacute thyroiditis, postpartum thyroiditis, Hashimoto's thyroiditis, and pamless thyroiditis. 4) 45% of hypothyroid patients had increased 24 hr RAIU, 30% of hypothyroid patients were normal, 25%, decreased. In conclusion, thyroid scan should be reevaluated its useful role to asses the pathophysiologic status of thyroid disease. Especially in cases of transient thyrotoxicosis, thyroid scan is essential to diagnose and follow up the disease process.

  3. Age- and sex-dependent model for estimating radioiodine dose to a normal thyroid

    International Nuclear Information System (INIS)

    Killough, G.G.; Eckerman, K.F.

    1985-01-01

    This paper describes the derivation of an age- and sex-dependent model of radioiodine dosimetry in the thyroid and the application of the model to estimating the thyroid dose for each of 4215 patients who were exposed to 131 I in diagnostic and therapeutic procedures. The model was made to conform to these data requirements by the use of age-specific estimates of the biological half-time of iodine in the thyroid and an age- and sex-dependent representation of the mass of the thyroid. Also, it was assumed that the thyroid burden was maximum 24 hours after administration (the 131 I dose is not critically sensitive to this assumption). The metabolic model is of the form A(t) = K[exp(-μ 1 t) - exp(-μ 2 t)] (μCi), where μ 1 = lambda/sub r/ + lambda/sub i//sup b/ (i = 1, 2), lambda/sub r/ is the radiological decay-rate coefficient, and lambda/sub i//sup b/ are biological removal rate coefficients. The values of lambda/sub i//sup b/ are determined by solving a nonlinear equation that depends on assumptions about the time of maximum uptake and the eventual biological loss rate (through which age dependence enters). The value of K may then be calculated from knowledge of the uptake at a particular time. The dosimetric S-factor (rad/μCi-day) is based on specific absorbed fractions for photons of energy ranging from 0.01 to 4.0 MeV for thyroid masses from 1.29 to 19.6 g; the functional form of the S-factor also involves the thyroid mass explicitly, through which the dependence on age and sex enters. An analysis of sensitivity of the model to uncertainties in the thyroid mass and the biological removal rate for several age groups is reported. The model could prove useful in the dosimetry of very short-lived radioiodines. Tables of age- and sex-dependent coefficients are provided to enable readers to make their own calculations. 12 refs., 5 figs., 4 tabs

  4. Analysis of thyroid absorbed dose in cervical CT scan with the use of bismuth shielding

    International Nuclear Information System (INIS)

    Santos, Fernanda S.; Gómez, Álvaro M.L.; Mourão, Arnaldo P.; Santana, Priscila C.

    2017-01-01

    The Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. Today, it is a very fast, painless and noninvasive test that can be performed high quality images. However, CT scan usually requires a higher radiation exposure dose than a conventional radiography examination. The aim of this study is to determine the dose variation deposited in thyroid and in nearby radiosensitive organs, such as: lenses, pharynx, hypophysis, salivary gland and spinal cord with and without the use of bismuth shielded. A cervical CT scan was performed on anthropomorphic male phantom model Alderson Rando, from the occipital to the first thoracic vertebra, using a GE scanner, Discovery model with 64 channels. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. After the phantom cervical CT scan the radiochromic film strips were processed for obtaining digital images. Digital images were worked to obtain the dose variation profiles for each film. With the data obtained, it was found the organ dose variation. The results show that the thyroid received the highest dose, 40.9 mGy, in the phantom, according to the incidence of the primary X-ray beam. (author)

  5. Analysis of thyroid absorbed dose in cervical CT scan with the use of bismuth shielding

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Fernanda S.; Gómez, Álvaro M.L.; Mourão, Arnaldo P., E-mail: fernanda.stephaniebh@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Santana, Priscila C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem

    2017-07-01

    The Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. Today, it is a very fast, painless and noninvasive test that can be performed high quality images. However, CT scan usually requires a higher radiation exposure dose than a conventional radiography examination. The aim of this study is to determine the dose variation deposited in thyroid and in nearby radiosensitive organs, such as: lenses, pharynx, hypophysis, salivary gland and spinal cord with and without the use of bismuth shielded. A cervical CT scan was performed on anthropomorphic male phantom model Alderson Rando, from the occipital to the first thoracic vertebra, using a GE scanner, Discovery model with 64 channels. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. After the phantom cervical CT scan the radiochromic film strips were processed for obtaining digital images. Digital images were worked to obtain the dose variation profiles for each film. With the data obtained, it was found the organ dose variation. The results show that the thyroid received the highest dose, 40.9 mGy, in the phantom, according to the incidence of the primary X-ray beam. (author)

  6. Supporting Treatment Decisions in Patients with Differentiated Thyroid Carcinoma (DTC) under Radioiodine-131 Therapy: Role of Biological Dosimetry Assessment

    International Nuclear Information System (INIS)

    Fadel, A.M.; Chebel, G.M.; Di Giorgio, M.; Vallerga, M.B.; Taja, M.R.; Radl, A.; Bubniak, R.V.; Oneto, A.

    2010-01-01

    Radioiodine-131 therapy is applied in patients with differentiated thyroid carcinoma (DTC), within the therapeutic scheme following thyroidectomy, for the ablation of thyroid remnants and treatment of metastatic disease. Several approaches for the selection of a therapeutic dose were applied. The aim of this therapy is to achieve a lethal dose in the tumor tissue, without exceeding the dose of tolerance in healthy tissues (doses greater than 2 Gy in bone marrow could lead to myelotoxicity). In this work, the treatment protocol used incorporates the assessment by biological dosimetry (BD) for estimating doses to whole body and bone marrow, to tailor patient's treatment. Biological Dosimetry prospective studies conducted on samples from patients with cumulative activities, before and after each therapeutic administration, allows to evaluate DNA damage and repair capacity in peripheral blood lymphocytes. (authors)

  7. Comparison of therapeutic efficacy and clinical parameters between recombinant human thyroid stimulating hormone and thyroid hormone withdrawal in high-dose radioiodine treatment with differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Se Hun; Na, Chang Ju; Kim, Jeong Hun; Han, Yeon Hee; KIm, Hee Kwon; Jeong, Hwan Jeong; Sohn, Myung Hee; Lim, Seok Tae [Dept. of Nuclear Medicine, Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of)

    2015-06-15

    High-dose radioiodine treatment (HD-RIT) after injection of recombinant human thyroid stimulating hormone (rh-TSH) has become widely used. This study compared the therapeutic efficacy of HD-RIT and clinical parameters between rh-TSH supplement and thyroid hormone withdrawal (THW) after total thyroidectomy in patients with differentiated thyroid cancer. We retrospectively reviewed 266 patients (47 male and 219 female; age, 49.0 ± 10.9 years) with differentiated thyroid cancer detected from September 2011 to September 2012. Patients comprised THW (217, 81.6 %) and rh-TSH (49, 18.4 %). Inclusion criteria were: first HD-RIT; any TN stage; absence of distant metastasis. To evaluate the complete ablation of the remnant thyroid tissue or metastasis, we reviewed stimulated serum thyroglobulin (sTg), I-123 whole-body scan (RxWBS) on T4 off-state, and thyroid ultrasonography (US) or [F-18]-fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) 6–8 months after HD-RIT. We defined a complete ablation state when all three of the follow-up conditions were satisfied; <2.0 ng/ml of the sTg, I-123 RxWBS (−), and thyroid US or F-18 FDG PET/CT (−). If one of the three was positive, ablation was considered incomplete. We also compared various clinical biomarkers (body weight, body mass index, liver and kidney function) between THW and rh-TSH groups. The rates of complete ablation were 73.7 % (160/217) for the THW group and 73.5 % (36/49) for the rh-TSH group. There was no significant difference between the two groups (p = 0.970). The follow-up aspartate transaminase (p = 0.001) and alanine transaminase (p = 0.001) were significantly higher in the THW group. The renal function parameters of blood urea nitrogen (p = 0.001) and creatinine (p = 0.005) tended to increase in the THW group. The change of body weight was + Δ0.96 (±1.9) kg for the THW group and was decreased by -Δ1.39 (±1.5) kg for the rh-TSH group. The change

  8. Low-dose irradiation to head, neck, or chest during infancy as a possible cause of thyroid carcinoma in teen-agers

    International Nuclear Information System (INIS)

    Yoshida, Akira; Fukuda, Katsuhiro; Noguchi, Shiro; Hirohata, Tomio.

    1987-01-01

    A matched case-control study was performed to identify the etiologic factors for thyroid carcinoma in teen-agers. Twenty-seven cases and 69 controls were investigated to assess the significance of various maternal and subject factors. Irradiation during infancy was the only factor which showed a statistically significant association with the incidence of thyroid cancer in teen-agers (summary χ 2 = 8.040; d.f. = 1; P < 0.005). The estimated dose ranged from 0.2 to 40 rads on the head, neck, or chest during infancy. (author)

  9. Age- and sex-dependent model for estimating radioiodine dose to a normal thyroid

    International Nuclear Information System (INIS)

    Killough, G.G.; Eckerman, K.F.

    1986-01-01

    This paper describes the derivation of an age- and sex-dependent model of radioiodine dosimetry in the thyroid and the application of the model to estimating the thyroid dose for each of 4215 patients who were exposed to 131 I in diagnostic and therapeutic procedures. In most cases, the available data consisted of the patient's age at the time of administration, the patient's sex, the quantity of activity administered, the clinically-determined uptake of radioiodine by the thyroid, and the time after administration at which the uptake was determined. The metabolic model is of the form A(t) = K[exp(-μ 1 t) -exp(-μ 2 t)] (μCi), where μ 1 = λ/sub r/ - λ/sub i//sup b/ (i = 1, 2), λ/sub r/ is the radiological decay-rate coefficient, and λ/sub i//sup b/ are biological removal rate coefficients. The values of λ/sub i//sup b/ are determined by solving a nonlinear equation that depends on assumptions about the time or maximum uptake an the eventual biological loss rate (through which age dependence enters). The value of K may then be calculated from knowledge of the uptakes at a particular time. The dosimetric S-factor (rad/μCi-day) is based on specific absorbed fractions for photons of energy ranging from 0.01 to 4.0 MeV for thyroid masses from 1.29 to 19.6 g; the functional form of the S-factor also involves the thyroid mass explicitly, through which the dependence on age and sex enters. An analysis of sensitivity of the model to uncertainties in the thyroid mass and the biological removal rate for several age groups is reported. 12 references, 5 figures, 5 tables

  10. Radiation Dose-rate Reduction Pattern in Well-differentiated Thyroid Cancer Treated with I-131.

    Science.gov (United States)

    Khan, Shahbaz Ahmad; Khan, Muhammad Saqib; Arif, Muhammad; Durr-e-Sabih; Rahim, Muhammad Kashif; Ahmad, Israr

    2015-07-01

    To determine the patterns of dose rate reduction in single and multiple radioiodine (I-131) therapies in cases of well differentiated thyroid cancer patients. Analytical series. Department of Nuclear Medicine and Radiation Physics, Multan Institute of Nuclear Medicine and Radiotherapy (MINAR), Multan, Pakistan, from December 2006 to December 2013. Ninety three patients (167 therapies) with well differentiated thyroid cancer treated with different doses of I-131 as an in-patient were inducted. Fifty four patients were given only single I-131 therapy dose ranging from 70 mCi (2590 MBq) to 150 mCi (5550 MBq). Thirty nine patients were treated with multiple I-131 radioisotope therapy doses ranging from 80 mCi (2960 MBq) to 250 mCi (9250 MBq). T-test was applied on the sample data showed statistically significant difference between the two groups with p-value (p < 0.01) less than 0.05 taken as significant. There were 68 females and 25 males with an age range of 15 to 80 years. Mean age of the patients were 36 years. Among the 93 cases of first time Radio Active Iodine (RAI) therapy, 59 cases (63%) were discharged after 48 hours. Among 39 patients who received RAI therapy second time or more, most were discharged earlier after achieving acceptable discharge dose rate i.e 25 µSv/hour; 2 out of 39 (5%) were discharged after 48 hours. In 58% patients, given single I-131 therapy dose, majority of these were discharged after 48 hours without any major complications. For well differentiated thyroid cancer patients, rapid dose rate reduction is seen in patients receiving second or subsequent radioiodine (RAI) therapy, as compared to first time receiving RAI therapy.

  11. Thyroid dose from 131 iodine of the population in Poland following the Chernobyl accident

    International Nuclear Information System (INIS)

    Krzesniak, J.W.

    1987-11-01

    The following studies were carried out in the period from 28 April to 20 June 1986 in the Central Laboratory of radiological Protection (C.L.O.R.) in Poland: atmosphere monitoring in the period from 28 April to 22 May evaluating 131 I environmental concentration with the percentage of iodine in elementary, aerosol and organic compound form; determination of thyroid dose in 1049 persons from mine regions in Poland [fr

  12. Environmental factors used for the estimation of radiation dose to thyroid gland

    International Nuclear Information System (INIS)

    Ohmomo, Yoichiro

    1976-01-01

    Environmental factors used for the estimation of radiation dose to thyroid gland were discussed in this paper, such as deposition velocity of radioactive iodine onto plant leaves, elimination factor from the leaves, transfer of this nuclide to milk and the consumption of those critical foods especially by inhabitants around nuclear sites in coastal area of Ibaraki Prefecture. Uptake of the stable iodine was estimated. (auth.)

  13. A comparison of physical and cytogenetic estimates of radiation dose in patients treated with iodine-131 for thyroid carcinoma

    International Nuclear Information System (INIS)

    Lloyd, D.C.; Purrott, R.J.; Dolphin, G.W.; Horton, P.W.; Halnan, K.E.; Scott, J.S.; Mair, G.

    1976-01-01

    Physical and cytogenetic estimates of the whole-body radiation doses have been compared in 11 patients receiving large doses of iodine-131 for the treatment of thyroid carcinoma. The physical estimate was based on the measurement of thyroid uptake, of the plasma activity variation, and of urinary activity. The cytogenetic estimate was obtained from the analysis of chromosome aberrations in peripheral blood lymphocytes. Good agreement between the estimates was observed in patients whose thyroid glands had previously be ablated by radioiodine. In patients who had varying degrees of thyroid function, there were considerable differences between the estimates with the cytogenetic value always being higher. It is suggested that these differences might be due in part to non-uniform irradiation of lymphocytes by local sources of activity in the thyroid and in the liver. (author)

  14. Disruption of thyroid hormone functions by low dose exposure of tributyltin: an in vitro and in vivo approach.

    Science.gov (United States)

    Sharan, Shruti; Nikhil, Kumar; Roy, Partha

    2014-09-15

    Triorganotins, such as tributyltin chloride (TBTCl), are environmental contaminants that are commonly found in the antifouling paints used in ships and other vessels. The importance of TBTCl as an endocrine-disrupting chemical (EDC) in different animal models is well known; however, its adverse effects on the thyroid gland are less understood. Hence, in the present study, we aimed to evaluate the thyroid-disrupting effects of this chemical using both in vitro and in vivo approaches. We used HepG2 hepatocarcinoma cells for the in vitro studies, as they are a thyroid hormone receptor (TR)-positive and thyroid responsive cell line. For the in vivo studies, Swiss albino male mice were exposed to three doses of TBTCl (0.5, 5 and 50μg/kg/day) for 45days. TBTCl showed a hypo-thyroidal effect in vivo. Low-dose treatment of TBTCl exposure markedly decreased the serum thyroid hormone levels via the down-regulation of the thyroid peroxidase (TPO) and thyroglobulin (Tg) genes by 40% and 25%, respectively, while augmenting the thyroid stimulating hormone (TSH) levels. Thyroid-stimulating hormone receptor (TSHR) expression was up-regulated in the thyroid glands of treated mice by 6.6-fold relative to vehicle-treated mice (p<0.05). In the transient transactivation assays, TBTCl suppressed T3 mediated transcriptional activity in a dose-dependent manner. In addition, TBTCl was found to decrease the expression of TR. The present study thus indicates that low concentrations of TBTCl suppress TR transcription by disrupting the physiological concentrations of T3/T4, followed by the recruitment of NCoR to TR, providing a novel insight into the thyroid hormone-disrupting effects of this chemical. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Low dose irradiation of thyroid cells reveals a unique transcriptomic and epigenetic signature in RET/PTC-positive cells

    Energy Technology Data Exchange (ETDEWEB)

    Abou-El-Ardat, Khalil, E-mail: kabouela@sckcen.be [Radiobiology Unit, Molecular and Cellular Biology, GKD Building, Studiecentrum voor Kernenergie - Centre d' Etude de l' Energie Nucleaire (SCK-CEN), Boeretang 200, 2400 Mol (Belgium); Department of Molecular Biotechnology, Faculty of Bioscience Engineering, Universiteit Gent, 9000 Ghent (Belgium); Monsieurs, Pieter [Radiobiology Unit, Molecular and Cellular Biology, GKD Building, Studiecentrum voor Kernenergie - Centre d' Etude de l' Energie Nucleaire (SCK-CEN), Boeretang 200, 2400 Mol (Belgium); Anastasov, Natasa; Atkinson, Mike [Department of Radiation Sciences, Helmholtz Zentrum Muenchen, Munich (Germany); Derradji, Hanane [Radiobiology Unit, Molecular and Cellular Biology, GKD Building, Studiecentrum voor Kernenergie - Centre d' Etude de l' Energie Nucleaire (SCK-CEN), Boeretang 200, 2400 Mol (Belgium); De Meyer, Tim [Department of Molecular Biotechnology, Faculty of Bioscience Engineering, Universiteit Gent, 9000 Ghent (Belgium); Department of Applied Mathematics, Biometrics and Process Control, Faculty of Bioscience Engineering, Universiteit Gent, 9000 Ghent (Belgium); Bekaert, Sofie [Clinical Research Center, Faculty for Medicine and Health Sciences, Universiteit Gent, 185 De Pintelaan, 9000 Ghent (Belgium); Van Criekinge, Wim [Department of Molecular Biotechnology, Faculty of Bioscience Engineering, Universiteit Gent, 9000 Ghent (Belgium); and others

    2012-03-01

    The high doses of radiation received in the wake of the Chernobyl incident and the atomic bombing of Hiroshima and Nagasaki have been linked to the increased appearance of thyroid cancer in the children living in the vicinity of the site. However, the data gathered on the effect of low doses of radiation on the thyroid remain limited. We have examined the genome wide transcriptional response of a culture of TPC-1 human cell line of papillary thyroid carcinoma origin with a RET/PTC1 translocation to various doses (0.0625, 0.5, and 4 Gy) of X-rays and compared it to response of thyroids with a RET/PTC3 translocation and against wild-type mouse thyroids irradiated with the same doses using Affymetrix microarrays. We have found considerable overlap at a high dose of 4 Gy in both RET/PTC-positive systems but no common genes at 62.5 mGy. In addition, the response of RET/PTC-positive system at all doses was distinct from the response of wild-type thyroids with both systems signaling down different pathways. Analysis of the response of microRNAs in TPC-1 cells revealed a radiation-responsive signature of microRNAs in addition to dose-responsive microRNAs. Our results point to the fact that a low dose of X-rays seems to have a significant proliferative effect on normal thyroids. This observation should be studied further as opposed to its effect on RET/PTC-positive thyroids which was subtle, anti-proliferative and system-dependent.

  16. Values of (99m)Tc-methoxyisobutylisonitrile imaging after first-time large-dose (131)I therapy in treating differentiated thyroid cancer.

    Science.gov (United States)

    Pan, Xiaomei; Duan, Dong; Zhu, Yuquan; Pang, Hua; Guan, Lili; Lv, Zhixiang

    2016-01-01

    The aim of this study is to investigate the use of (99m)Tc-methoxyisobutylisonitrile (MIBI) imaging for evaluating the treatment response of differentiated thyroid cancer (DTC) after the first administration of a high dose of (131)I. Patients with DTC who received (131)I therapy underwent (99m)Tc-MIBI imaging after successive increases in the therapeutic dose of (131)I, and the serum levels of thyroglobulin (Tg) were measured. A total of 191 patients were enrolled in the final analysis, including 65 metastases and/or thyroid remnant-positive patients (22 patients with metastases and 43 patients with thyroid remnants). The sensitivity of (99m)Tc-MIBI imaging for detecting positive cases and thyroid remnants was 56.9% and 39.5%, respectively, which was significantly lower than that of (131)I imaging (92.3% and 100%, respectively, PTc-MIBI imaging for detecting metastases was 90.9%, which was slightly higher than that of (131)I imaging (77.3%, P>0.05). The Tg levels in the positive group were significantly higher than that in the negative group (PTc-MIBI(+)/(131)I(-) group were significantly higher than that in the (131)I(+)/(99m)Tc-MIBI group (PTc-MIBI imaging was able to detect the existence of metastatic lesions in patients with DTC better, its assessment for the removal efficiency of thyroid remnants was unsatisfactory. The results of (99m)Tc-MIBI imaging showed good correlations with the Tg level.

  17. Dose concepts and dosimetry for radioiodine therapy of benign thyroid diseases

    International Nuclear Information System (INIS)

    Bockisch, A.; Brandt-Mainz, K.; Goerges, R.

    1997-01-01

    Dose planning prior to radioiodine therapy of benign thyroidal disease is usually based on macrodosimetry. The paper shows that this assumption is acceptable. The common concepts for dose planning are given. The following target doses are nowadays widely accepted: 150 Gy for euthyroid goiter, 400 Gy for toxic adenoma, 150 Gy for disserminated autonomy, 200 Gy for hyperthyroid Grave's disease if posttherapeutic euthyroidism is intended, and 250 (to 300) Gy if the risk of recurrency is to be minimized ('ablative' concept). Finally, a surveyfis given concerning the precision in which the parameters relevant for the dose calcultion can be determined. For realistic favourable conditions, the dose can be determined with an accuracy of better than ±25%. (orig.) [de

  18. Dose assessment in radiological accidents

    International Nuclear Information System (INIS)

    Donkor, S.

    2013-04-01

    The applications of ionizing radiation bring many benefits to humankind, ranging from power generation to uses in medicine, industry and agriculture. Facilities that use radiation source require special care in the design and operation of equipment to prevent radiation injury to workers or to the public. Despite considerable development of radiation safety, radiation accidents do happen. The purpose of this study is therefore to discuss how to assess doses to people who will be exposed to a range of internal and external radiation sources in the event of radiological accidents. This will go a long way to complement their medical assessment thereby helping to plan their treatment. Three radiological accidents were reviewed to learn about the causes of those accidents and the recommendations that were put in place to prevent recurrence of such accidents. Various types of dose assessment methods were discussed.(au)

  19. The thyroid nodule. Thyrotropin and peripheral thyroid hormones

    International Nuclear Information System (INIS)

    Zimny, M.

    2008-01-01

    Thyrotropin, free triodothyronine and thyroxine represent the standard serological parameters for the diagnostic work-up of the thyroid but only a minority of thyroid nodules present with subclinical or overt thyroid disorders. Besides a review of the regulation and principle of function of thyroid hormones as well as the effects of subclinical or overt hyperthyroidism, the significant role of these parameters beyond the assessment of hyperthyroidism in thyroid nodules is discussed. There is evidence that the level of thyrotropin within the normal range is predictive for the relevance of autonomous functioning nodules and the risk of malignancy of non-functioning thyroid nodules. Furthermore, the ratio of triodothyronine and thyroxine indicates the etiology of hyperthyroidism. Thyrotropin represents the main parameter to determine the adequate dose of thyroid hormone therapy of thyroid nodules. (orig.)

  20. Association of radiation dose with prevalence of thyroid nodules among atomic bomb survivors exposed in childhood (2007-2011).

    Science.gov (United States)

    Imaizumi, Misa; Ohishi, Waka; Nakashima, Eiji; Sera, Nobuko; Neriishi, Kazuo; Yamada, Michiko; Tatsukawa, Yoshimi; Takahashi, Ikuno; Fujiwara, Saeko; Sugino, Keizo; Ando, Takao; Usa, Toshiro; Kawakami, Atsushi; Akahoshi, Masazumi; Hida, Ayumi

    2015-02-01

    Few studies have evaluated the association of radiation dose with thyroid nodules among adults exposed to radiation in childhood. To evaluate radiation dose responses on the prevalence of thyroid nodules in atomic bomb survivors exposed in childhood. This survey study investigated 3087 Hiroshima and Nagasaki atomic bomb survivors who were younger than 10 years at exposure and participated in the thyroid study of the Adult Health Study at the Radiation Effects Research Foundation. Thyroid examinations including thyroid ultrasonography were conducted between October 2007 and October 2011, and solid nodules underwent fine-needle aspiration biopsy. Data from 2668 participants (86.4% of the total participants; mean age, 68.2 years; 1213 men; and 1455 women) with known atomic bomb thyroid radiation doses (mean dose, 0.182 Gy; median dose, 0.018 Gy; dose range, 0-4.040 Gy) were analyzed. The prevalence of all thyroid nodules having a diameter of 10 mm or more (consisting of solid nodules [malignant and benign] and cysts), prevalence of small thyroid nodules that were less than 10 mm in diameter detected by ultrasonography, and atomic bomb radiation dose-responses. Thyroid nodules with a diameter of 10 mm or more were identified in 470 participants (17.6%): solid nodules (427 cases [16.0%]), malignant tumors (47 cases [1.8%]), benign nodules (186 cases [7.0%]), and cysts (49 cases [1.8%]), and all were significantly associated with thyroid radiation dose. Excess odds ratios per gray unit were 1.65 (95% CI, 0.89-2.64) for all nodules, 1.72 (95% CI, 0.93-2.75) for solid nodules, 4.40 (95% CI, 1.75-9.97) for malignant tumors, 2.07 (95% CI, 1.16-3.39) for benign nodules, and 1.11 (95% CI, 0.15-3.12) for cysts. The interaction between age at exposure and the dose was significant for the prevalence of all nodules (P = .003) and solid nodules (P bomb survivors 62 to 66 years after their exposure in childhood. However, radiation exposure is not associated with small thyroid

  1. Reducing radiation doses to the breast, thyroid and gonads during diagnostic radiography

    International Nuclear Information System (INIS)

    Weatherburn, G.C.

    1983-01-01

    The skin entry and exit doses on patients undergoing routine radiographic examinations of areas in which the breast, thyroid and gonads are included in the primary beam were measured using thermoluminescent dosimeters. To obtain further information about patient doses, measurements were also made on a phantom at similar skin positions and at the positions of these organs. Comparisons of the doses to these radiosensitive organs were made for the antero-posterior and postero-anterior projections. In cases where it was found that the doses were reduced by the use of non-conventional relationship between the relative positions of the patient and the film, suggestions are made for the adaptations which would have to be made to X-ray equipment to enable these projections to be taken routinely. Other techniques, such as air gap techniques and thyroid shielding, whereby patient doses can be reduced during routine radiography are also examined. Finally the implications of these results for radiation protection of patients are considered. (author)

  2. Pregnancy after high therapeutic doses of iodine-131 in differentiated thyroid cancer: potential risks and recommendations

    International Nuclear Information System (INIS)

    Casara, D.; Rubello, D.; Saladini, G.; Piotto, A.; Pelizzo, M.R.; Girelli, M.E.; Busnardo, B.

    1993-01-01

    Seventy female patients who had been treated with high doses of iodine-131 for differented thyroid cancer (DTC) and who had a subsequent pregnancy were evaluated. The global 131 I dose ranged from 1.85 to 16.55 GBq (mean±SD=4.39±25.20 GBq). Age at first therapy ranged from 15 to 36 years (mean±SD=24.3±5.0 years) and the interval from 131 I therapy to pregnancy varied from 2 to 10 years (mean±SD=5.3±2.8 years). The estimated radiation dose to the gonads ranged from 10 to 63 cGy (mean±SD=24.0±13.5 cGy). All patients were treated with L-thyroxine at doses capable of suppressing thyroid-stimulating hormone. Seventy-three children were followed-up and seven pregnancies are still in progress. One child was affected by Fallot's trilogy and three had a low birth weight though with subsequent regular growth; the others were healthy with subsequent regular growth. No newborn with clinical or biochemical thyroid dysfunctions was found. Two spontaneous abortions during the second month of pregnancy were recorded. One of two patients in question subsequently had two healthy children. On the basis of these data, previous administration of high 131 I doses does not appear to be a valid reason for dissuading young female DTC patients from considering pregnancy. However, patients should be advised to avoid pregnancy after 131 I administration for a period sufficient to ensure complete elimination of the radionuclide and to permit confirmation of complete disease remission, i.e. at least 1 year in our opinion. (orig.)

  3. Dose assessments for SFR 1

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la

    2008-05-01

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  4. Dose assessments for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la (Facilia AB, Bromma (Sweden))

    2008-06-15

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  5. Assessment of internal doses in emergency situations

    Energy Technology Data Exchange (ETDEWEB)

    Rahola, T.; Muikku, M. [Radiation and Nuclear Safety Authority - STUK (Finland); Falk, R.; Johansson, J. [Swedish Radiation Protection Authority - SSI (Sweden); Liland, A.; Thorshaug, S. [NRPA (Norway)

    2006-04-15

    The need for assessing internal radiation doses in emergency situations was demonstrated after accidents in Brazil, Ukraine and other countries. Lately more and more concern has been expressed regarding malevolent use of radiation and radioactive materials. The scenarios for such use are more difficult to predict than for nuclear power plant or weapons accidents. Much of the results of the work done in the IRADES project can be adopted for use in various accidental situations involving radionuclides that are not addressed in this report. If an emergency situation occurs in only one or a few of the Nordic countries, experts from the other countries could be called upon to assist in monitoring. A big advantage is then our common platform. In the Nordic countries much work has been put down on quality assurance of measurements and on training of dose assessment calculations. Attention to this was addressed at the internal dosimetry course in October 2005. Nordic emergency preparedness exercises have so far not included training of direct measurements of people in the early phase of an emergency. The aim of the IRADES project was to improve the preparedness especially for thyroid measurements. The modest financial support did not enable the participants to make big efforts but certainly acted as a much appreciated reminder of the importance of being prepared also to handle situations with malevolent use of radioactive materials. It was left to each country to decide to which extent to improve the practical skills. There is still a need for detailed national implementation plans. Measurement strategies need to be developed in each country separately taking into account national regulations, local circumstances and resources. End users of the IRADES report are the radiation protection authorities. (au)

  6. Assessment of internal doses in emergency situations

    International Nuclear Information System (INIS)

    Rahola, T.; Muikku, M.; Falk, R.; Johansson, J.; Liland, A.; Thorshaug, S.

    2006-04-01

    The need for assessing internal radiation doses in emergency situations was demonstrated after accidents in Brazil, Ukraine and other countries. Lately more and more concern has been expressed regarding malevolent use of radiation and radioactive materials. The scenarios for such use are more difficult to predict than for nuclear power plant or weapons accidents. Much of the results of the work done in the IRADES project can be adopted for use in various accidental situations involving radionuclides that are not addressed in this report. If an emergency situation occurs in only one or a few of the Nordic countries, experts from the other countries could be called upon to assist in monitoring. A big advantage is then our common platform. In the Nordic countries much work has been put down on quality assurance of measurements and on training of dose assessment calculations. Attention to this was addressed at the internal dosimetry course in October 2005. Nordic emergency preparedness exercises have so far not included training of direct measurements of people in the early phase of an emergency. The aim of the IRADES project was to improve the preparedness especially for thyroid measurements. The modest financial support did not enable the participants to make big efforts but certainly acted as a much appreciated reminder of the importance of being prepared also to handle situations with malevolent use of radioactive materials. It was left to each country to decide to which extent to improve the practical skills. There is still a need for detailed national implementation plans. Measurement strategies need to be developed in each country separately taking into account national regulations, local circumstances and resources. End users of the IRADES report are the radiation protection authorities. (au)

  7. Thyroid absorbed dose for people at Rongelap, Utirik, and Sifo on March 1, 1954

    International Nuclear Information System (INIS)

    Lessard, E.T.; Miltenberger, R.P.; Conrad, R.A.; Musoline, S.V.; Naidu, J.R.; Moorthy, A.; Schopfer, C.J.

    1985-03-01

    A study was undertaken to reexamine thyroid absorbed dose estimates for people accidentally exposed to fallout at Rongelap, Sifo, and Utirik Islands from the Pacific weapon test known as Operation Castle BRAVO. The study included: (1) reevaluation of radiochemical analysis, to relate results from pooled urine to intake, retention, and excretion functions; (2) analysis of neutron-irradiation studies of archival soil samples, to estimate areal activities of the iodine isotopes; (3) analysis of source term, weather data, and meteorological functions used in predicting atmospheric diffusion and fallout deposition, to estimate airborne concentrations of the iodine isotopes; and (4) reevaluation of radioactive fallout, which contaminated a Japanese fishing vessel in the vicinity of Rongelap Island on March 1, 1954, to determine fallout components. The conclusions of the acute exposure study were that the population mean thyroid absorbed doses were 21 gray (2100 rad) at Rongelap, 6.7 gray (670 rad) at Sifo, and 2.8 gray (280 rad) at Utirik. The overall thyroid cancer risk we estimated was in agreement with results published on the Japanese exposed at Nagasaki and Hiroshima. We now postulate that the major route for intake of fallout was by direct ingestion of food prepared and consumed outdoors. 66 refs., 13 figs., 25 tabs

  8. Thyroid absorbed dose for people at Rongelap, Utirik, and Sifo on March 1, 1954

    Energy Technology Data Exchange (ETDEWEB)

    Lessard, E.T.; Miltenberger, R.P.; Conrad, R.A.; Musoline, S.V.; Naidu, J.R.; Moorthy, A.; Schopfer, C.J.

    1985-03-01

    A study was undertaken to reexamine thyroid absorbed dose estimates for people accidentally exposed to fallout at Rongelap, Sifo, and Utirik Islands from the Pacific weapon test known as Operation Castle BRAVO. The study included: (1) reevaluation of radiochemical analysis, to relate results from pooled urine to intake, retention, and excretion functions; (2) analysis of neutron-irradiation studies of archival soil samples, to estimate areal activities of the iodine isotopes; (3) analysis of source term, weather data, and meteorological functions used in predicting atmospheric diffusion and fallout deposition, to estimate airborne concentrations of the iodine isotopes; and (4) reevaluation of radioactive fallout, which contaminated a Japanese fishing vessel in the vicinity of Rongelap Island on March 1, 1954, to determine fallout components. The conclusions of the acute exposure study were that the population mean thyroid absorbed doses were 21 gray (2100 rad) at Rongelap, 6.7 gray (670 rad) at Sifo, and 2.8 gray (280 rad) at Utirik. The overall thyroid cancer risk we estimated was in agreement with results published on the Japanese exposed at Nagasaki and Hiroshima. We now postulate that the major route for intake of fallout was by direct ingestion of food prepared and consumed outdoors. 66 refs., 13 figs., 25 tabs.

  9. Occupational dose assessment and national dose registry system in Iran

    International Nuclear Information System (INIS)

    Jafari-Zadeh, M.; Nazeri, F.; Hosseini-Pooya, S. M.; Taheri, M.; Gheshlaghi, F.; Kardan, M. R.; Babakhani, A.; Rastkhah, N.; Yousefi-Nejad, F.; Darabi, M.; Oruji, T.; Gholamali-Zadeh, Z.; Karimi-Diba, J.; Kazemi-Movahed, A. A.; Dashti-Pour, M. R.; Enferadi, A.; Jahanbakhshian, M. H.; Sadegh-Khani, M. R.

    2011-01-01

    This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H p (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed. (authors)

  10. Lesion dose in differentiated thyroid carcinoma metastases after rhTSH or thyroid hormone withdrawal: {sup 124}I PET/CT dosimetric comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Freudenberg, Lutz Stefan; Jentzen, Walter; Brandau, Wolfgang; Bockisch, Andreas [University of Duisburg/Essen, Department of Nuclear Medicine, Essen (Germany); Petrich, Thorsten; Knapp, Wolfram H. [Hanover University School of Medicine, Department of Nuclear Medicine, Hanover (Germany); Froemke, Cornelia [Hanover University School of Medicine, Institute of Biometry, Hanover (Germany); Marlowe, Robert J. [Spencer-Fontayne Corporation, Jersey City, NJ (United States); Heusner, Till [University of Duisburg/Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2010-12-15

    Renal radioiodine excretion is {proportional_to}50% faster during euthyroidism versus hypothyroidism. We therefore sought to assess lesion dose/GBq of administered {sup 131}I activity (LDpA) in iodine-avid metastases (IAM) of differentiated thyroid carcinoma (DTC) in athyreotic patients after recombinant human thyroid-stimulating hormone (rhTSH) versus after thyroid hormone withdrawal (THW). We retrospectively compared mean LDpA between groups of consecutive patients (N = 63) receiving {sup 124}I positron emission tomography/computed tomography ({sup 124}I PET/CT) aided by rhTSH (n = 27) or THW (n = 36); we prospectively compared LDpA after these stimulation methods within another individual. Data derived from serial PET scans and one CT scan performed 2-96 h post-{sup 124}I ingestion. A mixed model analysis of covariance (ANCOVA) calculated the treatment groups' mean LDpAs adjusting for statistically significant baseline intergroup differences: non-IAM were more prevalent, median IAM count/patient lower in cervical lymph nodes and higher in distant sites, median stimulated thyroglobulin higher, mean cumulative radioiodine activity greater and prior diagnostic scintigraphy more frequent in the rhTSH patients. Mean LDpAs were: rhTSH group (n = 71 IAM), 30.6 Gy/GBq; THW group (n = 66 IAM), 51.8 Gy/GBq. The difference in group means (rhTSH less THW), -21.2 Gy/GBq, was statistically non-significant (p = 0.1667). However, the 95% confidence interval of that difference (-51.4 to + 9 Gy/GBq) suggested a trend favouring THW. The within-patient comparison found 2.9- to 10-fold higher LDpAs under THW. We found some suggestions, but no statistically significant evidence, that rhTSH administration results in a lower radiation dose to DTC metastases than does THW. A large, well-controlled, prospective within-patient study should resolve this issue. (orig.)

  11. Thyroid dose measurement in patients undergoing to digital orthopantomography using optical stimulation dosimeters

    International Nuclear Information System (INIS)

    Gutierrez M, J. G.; Lopez V, A.; Rivera M, T.; Avalos P, L. Y.

    2016-10-01

    In this paper we present the study of the thyroid equivalent dose in 300 patients undergoing to digital orthopantomography for dental treatment purposes using optical stimulation dosimeters (OSL) as in-vivo dosimeters, in order to verify if this is within acceptable parameters to prevent stochastic risks and to evaluate the possible risks caused by the technique used for this type of study (66 kv, 5 m A, 14.1 s). Three OSL dosimeters were used per patient, which were placed by the physician on the skin above the thyroid gland (using anatomical references and palpation); the information of the patients was divided by neck size and sex, finding a slight increase in the equivalent dose for female and small size patient, this combination being the group that was submitted to a higher dose. The results obtained were compared with similar studies performed on anthropomorphic mannequins with TLD dosimeters obtaining lower results. The equivalent dose found even though is below the threshold stochastic damage must be motorized for radiological protection and registration purposes. (Author)

  12. The usefulness of Al face block fabrication for reducing exposure dose of thyroid glands in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Eun Ae [Dept. of Diagnostic Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, In Ja [Dept. of Radiologic Technology, Dongnam Health College, Suwon (Korea, Republic of)

    2013-03-15

    Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65 cm, 28 kVp, and 63 mAs. The measuring instrument was Flukes Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients anxiety during breast imaging. The Face Block is expected to improve patients satisfaction and contribute to reducing patients exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

  13. Thyroid carcinoma after radioiodide therapy for hyperthyroidism. Analysis based on age, latency, and administered dose of I-131

    International Nuclear Information System (INIS)

    Spencer, R.P.; Chapman, C.N.; Rao, H.

    1983-01-01

    Twenty-five reports in the medical literature of thyroid carcinomas which were detected after radioiodide therapy for hyperthyroidism were reviewed. These cases did not show a usual characteristic of radiation-associated tumors, namely a long latency period. That is, in 8/25 the latency period was under five years, and the mean latency was only 7.3 years. Further, there was no relationship between latency and age at treatment, or between latency and the dose of radioiodide employed. In 15/25 of the cases, there were known thyroid nodules. Three of the patients had thyroiditis (which itself has a correlation with thyroid carcinoma), and one individual had prior head and neck external radiation. There was no substantiating evidence that radioiodide treatment for hyperthyroidism was the cause of these thyroid carcinomas

  14. Hormones of thyroid gland in sera of rats treated with different dose of concentrated potassium iodine solutions

    Directory of Open Access Journals (Sweden)

    Marković Ljiljana

    2010-01-01

    Full Text Available Introduction Potassium iodine (KI is used as a drug therapy for treating numerous diseases such as small-vessel vasculitis, erythema nodosum, vasculitis nodularis, Sweet's syndrome, tuberculosis and granulomatosis, and for iodized salt. At the same time, KI can be harmful. Iodine intake may increase the frequency of thyroiditis in humans, and may induce the occurrence of experimental thyroiditis (ET in animals. Investigations on an experimental model for the examination of thyroiditis in Wistar rats have clearly showed morphological changes in the rat thyroid evoked by KI administration. Objective The purpose of this study was to compare the effects of low and high doses of KI on the thyroid gland of Wistar rats and determine the effect on hormone status (T4, T3 and TSH in this rat strain. Methods Two groups of rats from the Wistar strain were treated with a low iodine dose (225 μg/g BW and with a high iodine dose (675 μg/g BW of KI solutions. Untreated nonimmunized animals served as controls. The solution was administrated daily intraperitoneally during the period of 26 consecutive days. Results Monitoring hormone status (TSH, T3 and T4 and morphological changes it was found that therapeutic doses of KI applied in treatment induced the occurrence of experimental thyroiditis (chronic destructive Hashimoto's thyroiditis in humans and cell necrosis in animals not carrying a genetic susceptibility. Significant inflammatory changes were observed in rats treated with a high iodine dose. Conclusion The early iodine induced cell necrosis and inflammation in the nonimmunized animals without genetic susceptibility is a new experimental model of thyroiditis. .

  15. Standard dose 131I therapy for hyperthyroidism caused by autonomously functioning thyroid nodules

    International Nuclear Information System (INIS)

    Fui, S.C.N.T.; Maisey, M.N.

    1979-01-01

    Thirty-one patients with hyperthyroidism shown on scintigrams to have autonomously functioning thyroid nodules were treated with a standard dose of 15mCi of 131 I. Of thirty patients who have been followed up for at least 6 months to over 3 years, all but one patient were euthyroid after a single dose. Repeat scintigram and Thyrotropin Releasing Hormone test after therapy confirmed that twenty-five patients were cured of the disease. Only one patient developed hypothyroidism. This simplified dose regimen of radioiodine is effective in the treatment of hyperthyroidism caused by autonomously functioning nodules and is not complicated by the high incidence of hyperthyroidism that is observed following radioiodine therapy of Grave's disease. (author)

  16. Low- and high-dose radioiodine therapy for low-/intermediate-risk differentiated thyroid cancer. A preliminary clinical trial

    International Nuclear Information System (INIS)

    Qu Yuan; Huang Rui; Li Lin

    2017-01-01

    To compare the ablation results, therapeutic responses and adverse reactions between a low dose (1.1 GBq) or high dose (3.7 GBq) of 131 I in low-/intermediate-risk differentiated thyroid cancer (DTC) patients. The factors influencing the ablation result and therapeutic response were also analyzed. The researchers used a random number table to randomly assign the enrolled patients to the low-dose group or high-dose group at a 1:1 ratio, and assessment of ablation result, therapeutic response, and adverse reactions evaluated 6 ± 3 months after therapy. A total of 140 patients were enrolled in the study through October 2014-June 2015. Until February 2016, 132 patients completed the trial. 99 patients were re-examined under thyroid-stimulating hormone (TSH) stimulation 3-9 months after 131 I therapy. For the low-dose and high-dose groups, the success rates of ablation were 52.7% (29/55) and 59.1% (26/44), respectively. The ablation results did not differ significantly between the two groups (P = 0.548). One hundred and thirty two patients were re-examined 2-9 months after 131 I therapy. The low-dose group had an excellent response rate of ∼80% (53/66), an indeterminate response rate of ∼ 20% (13/66), and no cases with a biochemical incomplete response. The high-dose group had an excellent response rate of ∼85% (36/66), an indeterminate response rate of ∼11% (7/66), and a biochemical incomplete response rate of ∼4% (3/66). No significant differences in the therapeutic response were observed between the two groups (P = 0.087). Patients in stage N1b had a significantly lower success rate of ablation than those in stage N0 (P = 0.000). The success rate of ablation increased significantly with lower thyroglobulin (Tg) levels (P = 0.000). A pre-treatment Tg level was significantly associated with a higher excellent response rate (P = 0.002). Pre-treatment-stimulated Tg of 0.47 and 3.09 μg/L were identified as cut-off values for predicting the ablation result and

  17. Therapeutic administration of 131I for differentiated thyroid cancer, radiation dose to ovaries and outcome of pregnancies

    International Nuclear Information System (INIS)

    Garsi, Jerome-Philippe; Rubino, Carole; Labbe, Martine; Vathaire, Florent de; Schlumberger, Martin; Ricard, Marcel; Ceccarelli, Claudia; Schvartz, Claire; Henri- Amar, Michel; Bardet, Stephane

    2008-01-01

    Full text: Background: Radiation is known to be mutagenic. In thyroid cancer treatment, 131 I is usually administered, for the first treatment, at a 3.7 GMBq activity, corresponding to an estimated mean radiation dose of 140 mGy to the ovaries. However data on the effects of 131 I therapy on pregnancy outcomes, especially untoward, are scarce. Methods: Data on 2673 pregnancies were obtained by interviewing female patients treated for thyroid carcinoma who had not received external radiation to the ovaries, in three French hospitals and one Italian hospital. Results: The incidence of miscarriages was 10 % before any treatment for thyroid cancer; this percentage increased after surgery for thyroid cancer, both before (20 %) and after (19 %) 131 I treatment, with no variation according to the cumulative dose. Miscarriages were not significantly more frequent in women treated with 131 I during the year before conception, even in subjects who had received more than 370 MBq during that year, as compared to women never treated with 131 I. The incidence of stillbirths, preterm births, a low birth weight, congenital malformation and death during the first year of life was not significantly different before or after 131 I therapy. The incidence of thyroid and non thyroidal cancers was similar in children born either before or after the mother's exposure to 131 I. Conclusion: In our data, we found no evidence that exposure to 131 I affects the outcome of subsequent pregnancies and offspring. Whether the number of malformations, or thyroid and non thyroidal cancers are related to gonadal irradiation remains to be established. Our findings allowed us to fuel the debate on the doubling dose: the concept is still heatedly debated and the value of 1 Gy as the doubling dose in humans should be rediscussed. (author)

  18. Mixed species radioiodine air sampling readout and dose assessment system

    International Nuclear Information System (INIS)

    Distenfeld, C.H.; Klemish, J.R. Jr.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector

  19. High-dose radioiodine treatment for differentiated thyroid carcinoma is not associated with change in female fertility or any genetic risk to the offspring

    International Nuclear Information System (INIS)

    Bal, Chandrasekhar; Kumar, Ajay; Tripathi, Madhavi; Chandrashekar, Narayana; Phom, Hentok; Murali, Nadig R.; Chandra, Prem; Pant, Gauri S.

    2005-01-01

    Background: We tried to evaluate the female fertility and genetic risk to the offspring from the exposure to high-dose 131 I by assessing the pregnancy outcomes and health status of the children of female patients with differentiated thyroid cancer who had received therapeutic doses of 131 I. Materials and Methods: From 1967 to 2002, a total of 1,282 women had been treated with 131 I. Of these patients, 692 (54%) were in the reproductive age group (18-45 years). Forty women had a total of 50 pregnancies after high-dose 131 I. Age at presentation ranged from 16 to 36 years (mean, 23 ± 4 years). Histopathology was papillary thyroid cancer in 32 cases and follicular thyroid cancer in 8 cases. Results: Single high-dose therapy was given in 30 cases, 2 doses were given in 7 cases, 3 doses were given in 2 cases, and four doses were given in 1 case in which lung metastases had occurred. In 37 patients (92%), disease was successfully ablated before pregnancy. Ovarian absorbed-radiation dose calculated by the MIRD method ranged from 3.5 to 60 cGy (mean, 12 ± 11 cGy). The interval between 131 I therapy and pregnancy varied from 7 to 120 months (37.4 ± 28.2 months). Three spontaneous abortions occurred in 2 women. Forty-seven babies (20 females and 27 males) were born. Forty-four babies were healthy with normal birth weight and normal developmental milestones. Twenty women delivered their first baby after 131 I therapy. The youngest child in our series is 11 months of age, and the oldest is 8.5 years of age. Conclusions: Female fertility is not affected by high-dose radioiodine treatment, and the therapy does not appear to be associated with any genetic risks to the offspring

  20. Modeling the absorbed dose to the common carotid arteries following radioiodine treatment of benign thyroid disease

    DEFF Research Database (Denmark)

    la Cour, Jeppe Lerche; Hedemann-Jensen, Per; Søgaard-Hansen, Jens

    2013-01-01

    External fractionated radiotherapy of cancer increases the risk of cardio- and cerebrovascular events, but less attention has been paid to the potential side effects on the arteries following internal radiotherapy with radioactive iodine (RAI), i.e. 131-iodine. About 279 per million citizens...... in the western countries are treated each year with RAI for benign thyroid disorders (about 140,000 a year in the EU), stressing that it is of clinical importance to be aware of even rare radiation-induced side effects. In order to induce or accelerate atherosclerosis, the dose to the carotid arteries has...

  1. Thyroid equivalent doses due to radioiodine-131 intake for evacuees from Fukushima Daiichi Nuclear Power Plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Tokonami, Shinji; Sorimachi, Atsuyuki; Kashiwakura, Ikuo [Hirosaki University, Institute of Radiation Emergency Medicine, Hirosaki, Aomori (Japan); Hosoda, Masahiro [Hirosaki University, Graduate School of Health Sciences, Hirosaki, Aomori (Japan); Akiba, Suminori [Kagoshima University, Graduate School of Medical and Dental Sciences, Kagoshima (Japan); Balonov, Mikhail [Protection Laboratory, Institute of Radiation Hygiene, Petersburg (Russian Federation)

    2012-11-15

    A primary health concern among residents and evacuees in affected areas immediately after a nuclear accident is the internal exposure of the thyroid to radioiodine, particularly I-131, and subsequent thyroid cancer risk. In Japan, the natural disasters of the earthquake and tsunami in March 2011 destroyed an important function of the Fukushima Daiichi Nuclear Power Plant (F1-NPP) and a large amount of radioactive material was released to the environment. Here we report for the first time extensive measurements of the exposure to I-131 revealing I-131 activity in the thyroid of 46 out of the 62 residents and evacuees measured. The median thyroid equivalent dose was estimated to be 4.2 mSv and 3.5 mSv for children and adults, respectively, much smaller than the mean thyroid dose in the Chernobyl accident (490 mSv in evacuees). Maximum thyroid doses for children and adults were 23 mSv and 33 mSv, respectively. (author)

  2. 3D ultrasonography is as accurate as low-dose CT in thyroid volumetry.

    Science.gov (United States)

    Licht, K; Darr, A; Opfermann, T; Winkens, T; Freesmeyer, M

    2014-01-01

    The purpose of this study was to compare thyroid volumetry by three-dimensional mechanically swept ultrasonography (3DmsUS) and low-dose computed tomography (ldCT). 30 subjects referred for radioiodine therapy of benign thyroid diseases were subjected to 3DmsUS and ldCT. A prerequisite of 3DmsUS analyses was that the scans had to capture the entire thyroid, excluding therefore cases with a very large volume or retrosternal portions. The 3DmsUS data were transformed into a DICOM format, and volumetry calculations were performed via a multimodal workstation equipped with standard software for cross-sectional imaging. Volume was calculated applying both the ellipsoid model and a manually tracing method. Statistical analyses included 95% confidence intervals (CI) of the means and limits of agreement according to Bland and Altman, the latter including 95% of all expected values. Volumetric measurements by 3DmsUS and ldCT resulted in very high, significant correlation coefficients, r = 0.997 using the ellipsoid model and r = 0.993 with the manually tracing method. The mean relative differences of the two imaging modalities proved very small (-1.2±4.0% [95% CI -2.62; 0.28] using the ellipsoid model; -1.1±5.2% [95% CI -2.93; 0.80] using the manually tracing method) and the limits of agreement sufficiently narrow (-9.1% to 6.8%; -11.3% to 9.2%, respectively). For moderately enlarged thyroids, volumetry with 3DmsUS proved comparable to that of ldCT, irrespective of whether the ellipsoid model or the manually tracing method was applied. Thus, 3DmsUS qualifies as a potential alternative to ldCT, provided that the organ is completely accessible. The use of a standard workstation for cross-sectional imaging with routine software did not prove problematic.

  3. Usefulness of recombinant human TSH aided radioiodine doses administered in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Pitoia, Fabian; El Tamer, Elias; Schere, Daniel B.; Passerieu, Mariano; Bruno, Oscar D.; Niepominiszcze, Hugo

    2006-01-01

    The published studies confirming the safety and efficacy of rh TSH for diagnostic purposes have led to an increased interest in its use for preparation for radioiodine (RI) dose administration in patients with recurrent or persistent differentiated thyroid carcinoma (DTC). In order to establish the efficacy of RI therapy after rh TSH, we have reviewed 39 rh TSH-aided radioiodine treatments in a series of 28 DTC patients. Patients were divided into two groups: GI (n=17), with previous thyroid bed uptake and undetectable thyroglobulin (Tg) levels under levothyroxine treatment and GII (n=11), with proven metastatic local or distant disease. Median follow-up after the first rh TSH-aided radioiodine treatment was 32 ± 13 months (range 8 to 54 months). Sixteen patients (94%) in GI were rendered disease free and one patient was shown to have persistent disease. In GII, the post therapy whole body scan showed pathological uptakes in all cases: in four patients in lungs, in four in mediastinum and in three in lateral neck. In two patients with mediastinum uptake, Tg levels were undetectable after rh TSH. In the follow-up, two patients with lateral neck uptake were rendered disease free, four patients died (three due to thyroid cancer) and five out of the remaining patients have persistent disease. In conclusion, rh TSH aided therapy was helpful to eliminate normal thyroid bed remnants in 16/17 (94%) patients (GI). rh TSH stimulated Tg was undetectable in two patients with mediastinal metastasis. We believe that rh TSH is a good alternative to levothyroxine withdrawal for the treatment of DTC with radioactive iodine, increasing the quality of life in these patients. Caution should be recommended in the follow-up of unselected DTC patients only with stimulated Tg levels. (author) [es

  4. Internal dose assessment in nuclear medicine: fetal doses due to radiopharmaceutical administration to the mother

    International Nuclear Information System (INIS)

    Rojo, Ana M.; Michelin, Severino C.

    2004-01-01

    The objective of this publication is to present a guideline for the dose assessment through a comprehensive introduction of knowledge on ionizing radiation, radiation protection during pregnancy and fetal dosimetry for physician and other professionals involved in nuclear medicine practices. It contains tables with recommended dose estimates at all stages of pregnancy for many radiopharmaceuticals. Compounds for which some information was available regarding placental crossover are shown in shaded rows. It includes the most common diagnostic and therapy practices in nuclear medicine considering the four radioactive isotopes selected: 99m Tc, 131 I, 201 Tl and 67 Ga. There is a special case included, it is when conception occurs after the iodine has been administered. In almost every case, the diagnostic benefit to the mother outweighs the risk of any irradiation of the fetus. However, there is one situation in which severe fetal injury can be incurred from administering a radiopharmaceutical to the mother, and that is use of iodine-131 therapy for ablation of the thyroid in cases of hyperthyroidism or carcinoma. Radioactive iodine readily crosses the placenta and concentrates in the fetal thyroid, where, because of its small organ mass, high radiation doses are received. (author)

  5. Comparison of the Influence on the Liver Function Between Thyroid Hormone Withdrawal and rh-TSH Before High-Dose Radioiodine Therapy in Patients with Well-Differentiated Thyroid Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Han, Yeon-Hee; Lim, Seok Tae; Yun, Kuk-No; Yim, Sung Kyun; Kim, Dong Wook; Jeong, Hwan-Jeong; Sohn, Myung-Hee [Chonbuk National Univ. Medical School and Hospital, Jeonju (Korea, Republic of)

    2012-06-15

    An elevated thyroid stimulating hormone level (TSH) is essential to stimulate the uptake of radioiodine into thyroid remnants and metastases and metastases of thyroid cancer when a patient under-goes high-dose radioiodine therapy. Nowadays, recombinant human thyroid stimulating hormone (rh-TSH) is increasingly used instead of the classic method of thyroid hormone withdrawal (THW). However, beyond the therapeutic effects, clinical differences between the two methods have not yet been clearly demonstrated. The aim of this work was to investigate the effects of the two methods, especially on liver function. We identified 143 evaluable patients who were further divided into two groups: THW and rh-TSH. We first reviewed the aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels, which were measured during the admission period for total thyroidectomy. We called these liver enzyme levels 'base AST' and 'base ALT.' We also assessed other chemistry profiles, including AST, ALT, total cholesterol, LDL cholesterol, alkaline phosphatase (ALP), total bilirubin (TB), and triglyceride (TG), which were measured on admission day for high-dose radioiodine therapy. We called these liver enzyme levels 'follow-up AST'and 'follow-up ALT.' We compared the changes in base and follow-up liver enzyme levels and the other chemistry profiles between the two groups. The base AST and base ALT levels of the two groups were within normal range, and there was no significant difference between the two groups. In contrast to these base liver enzyme levels, follow-up AST and ALT levels than did the rh-TSH group. Patients in the THW group. Patients in the THW group also had higher levels of total cholesterol and LDL cholesterol than did the patients in the rh-TSH group. However there were no statistically significant differences in ALP, total bilirubin, and triglyceride levels between the two groups. In this retrospective analysis of liver

  6. Validation of American Thyroid Association Ultrasound Risk Assessment of Thyroid Nodules Selected for Ultrasound Fine-Needle Aspiration.

    Science.gov (United States)

    Tang, Alice L; Falciglia, Mercedes; Yang, Huaitao; Mark, Jonathan R; Steward, David L

    2017-08-01

    The aim of this study was to validate the American Thyroid Association (ATA) sonographic risk assessment of thyroid nodules. The ATA sonographic risk assessment was prospectively applied to 206 thyroid nodules selected for ultrasound-guided fine-needle aspiration (US-FNA), and analyzed with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), as well as surgical pathology for the subset undergoing surgical excision. The analysis included 206 thyroid nodules averaging 2.4 cm (range 1-7 cm; standard error of the mean 0.07). Using the ATA US pattern risk assessment, nodules were classified as high (4%), intermediate (31%), low (38%), and very low (26%) risk of malignancy. Nodule size was inversely correlated with sonographic risk assessment, as lower risk nodules were larger on average (p risk estimates (high 70-90%, intermediate 10-20%, low 5-10%, and very low 3%). ATA US pattern risk assessment also appropriately predicted the proportion of nodules classified as malignant or suspicious for malignancy through TBSRTC classification-high (77%), intermediate (6%), low (1%), and very low 0%-as well as benign TBSRTC classification-high (0%), intermediate (47%), low (61%), and very low (70%) (p risk stratification (high 100%, intermediate 21%, low 17%, and very low 12%; p = 0.003). This prospective study supports the new ATA sonographic pattern risk assessment for selection of thyroid nodules for US-FNA based upon TBSRTC and surgical pathology results. In the setting of indeterminate cytopathology, nodules categorized as atypia of undetermined significance/follicular lesion of undetermined significance with ATA high-risk sonographic patterns have a high likelihood of being malignant.

  7. Role of serum thyroglobulin levels in the assessment of thyroid disease (abstract)

    International Nuclear Information System (INIS)

    Abbas, H.G.; Khan, M.S.

    1998-01-01

    Thyroglobulin (Tg), a glycoprotein, is the principal iodoprotein of the thyroid gland and is the major component of the thyroid mass. As Tg is specific to thyroid gland and thyroid related-cells, its measurement in the circulation is potentially useful to study the pathogenesis, establish the diagnosis and follow the course of thyroid disorders. Serum Tg is a suitable marker for the differentiated thyroid carcinoma after total thyroid ablation by surgery and /sup 131/I treatment. Radioimmunoassay (RIA) and immunoradiometric (IRMA) methodologies are important to measure hormones for diagnosis of various diseases. In addition to /sup 131/I uptake, /sup 131/I whole body scintigraphy and estimation of T3, T4 and TSH levels, serum Tg levels in euthyroids (n=42), hyper thyroids (n=55) and treated cases (thyroidectomy and /sup 131/I ablation) of carcinoma (CA) thyroid were 9.7 - +9.96, 109.9 - +160.3 and 2.2 - + 4.2 respectively. Serum Tg levels were significantly higher (P < 0.005) in hyper thyroids and significantly lower (P < 0.025) in treated CA thyroids when compared with those of euthyroids. In treated patients (surgery and /sup 131/I ablation) serum Tg assay is an excellent method to assess the treatment and recurrence of disease. (author)

  8. External dose measurements for patients receiving therapeutic I-131 for thyroid cancer

    International Nuclear Information System (INIS)

    Molfetas, M.; Kottou, S.

    2002-01-01

    Iodine-131 is a well established and effective treatment, supplementing surgery, in differentiated thyroid carcinoma. Iodine-131 except from its β-emission, that generates a cell-killing effect in a small area, has also a γ-emission irradiating distant tissues and even people who are close enough with the treated patient. The International Commission on Radiation Protection, ICRP has estimated the probability of a radiation-induced fatal cancer for the whole population at 5.0 % per sievert for low doses and at low dose rates and at 1.3 % for serious genetic diseases. For elderly people the probability seems to be 3 to 10 times lower, whereas for children up to the age of 10 years, 2-3 times higher. These findings led the ICRP to recommend new dose limits, lower than the previous ones. The European Union has endorsed the ICRP recommendations and the Council issued two directives, with which the Greek legislation complied recently. The current annual public dose limit is 1 mSv, while in the new Greek legislation the concept of dose constrains (0.5 m Sv in Greece) has also been proposed as a goal to reach whenever possible

  9. Estimate of dose in crystalline and thyroid in exam complete periapical

    International Nuclear Information System (INIS)

    Bonzoumet, S.P.J.; Braz, D.; Barroso, R.C.; Mauricio, C.L.P.; Domingues, C.; Padilha, L.G.F.

    2006-01-01

    The constant achievement of dental radiography portrays the necessity of care in this practice for neither patient nor professional subject to a risk of excessive radiation. The main aim of this work is to estimate the crystalline and thyroid absorbed dose, during dental radiography. To evaluate the dose distribution it was used thermoluminescent dosimeter T.L.D.100. The measures were carried out on patients during intra-oral dental radiography in some dental clinics in Rio de Janeiro. Three dental equipments were investigated: Dhabi ATLANTE 1070, DABI ATLANTE 70x and SELETRONIC 70x. Analyzing the doses evaluated, it can be observed that there is a variation in the obtained values for the three points studied and for the three equipments utilized. It was noticed that while using the DABI1070, a larger dose was taken because of the size field diameter to equipment. In the 70x equipment was that one what obtains best results in every points. The results obtained from the SELETRONIC 70x have shown that there is a difference in two techniques used: with the positioner or without it. This achieved values superior than that, because the tip of patient was on display straight to radiation. This study was useful to confirm the excessive dose, besides of not was biased to nothing for the radiography quality,represents a risk for the patient who retains unnecessary and harmful radiation to system. (authors)

  10. Estimate of dose in crystalline and thyroid in exam complete periapical

    Energy Technology Data Exchange (ETDEWEB)

    Bonzoumet, S.P.J.; Braz, D. [Lab. de Instrumentacao Nuclear, COPPE/UFRJ, CEP, Rio de Janeiro (Brazil); Barroso, R.C. [Rio de Janeiro Univ. do Estado, Instituto de Fisica (Brazil); Mauricio, C.L.P.; Domingues, C. [Instituto de Radioprotecao e Dosimetria IRD / CNEN (Brazil); Padilha, L.G.F. [Rio de Janeiro Univ. Federal, Hospital Universitario (Brazil)

    2006-07-01

    The constant achievement of dental radiography portrays the necessity of care in this practice for neither patient nor professional subject to a risk of excessive radiation. The main aim of this work is to estimate the crystalline and thyroid absorbed dose, during dental radiography. To evaluate the dose distribution it was used thermoluminescent dosimeter T.L.D.100. The measures were carried out on patients during intra-oral dental radiography in some dental clinics in Rio de Janeiro. Three dental equipments were investigated: Dhabi ATLANTE 1070, DABI ATLANTE 70x and SELETRONIC 70x. Analyzing the doses evaluated, it can be observed that there is a variation in the obtained values for the three points studied and for the three equipments utilized. It was noticed that while using the DABI1070, a larger dose was taken because of the size field diameter to equipment. In the 70x equipment was that one what obtains best results in every points. The results obtained from the SELETRONIC 70x have shown that there is a difference in two techniques used: with the positioner or without it. This achieved values superior than that, because the tip of patient was on display straight to radiation. This study was useful to confirm the excessive dose, besides of not was biased to nothing for the radiography quality,represents a risk for the patient who retains unnecessary and harmful radiation to system. (authors)

  11. Transcriptional Response in Mouse Thyroid Tissue after 211At Administration: Effects of Absorbed Dose, Initial Dose-Rate and Time after Administration.

    Directory of Open Access Journals (Sweden)

    Nils Rudqvist

    Full Text Available 211At-labeled radiopharmaceuticals are potentially useful for tumor therapy. However, a limitation has been the preferential accumulation of released 211At in the thyroid gland, which is a critical organ for such therapy. The aim of this study was to determine the effect of absorbed dose, dose-rate, and time after 211At exposure on genome-wide transcriptional expression in mouse thyroid gland.BALB/c mice were i.v. injected with 1.7, 7.5 or 100 kBq 211At. Animals injected with 1.7 kBq were killed after 1, 6, or 168 h with mean thyroid absorbed doses of 0.023, 0.32, and 1.8 Gy, respectively. Animals injected with 7.5 and 100 kBq were killed after 6 and 1 h, respectively; mean thyroid absorbed dose was 1.4 Gy. Total RNA was extracted from pooled thyroids and the Illumina RNA microarray platform was used to determine mRNA levels. Differentially expressed transcripts and enriched GO terms were determined with adjusted p-value 1.5, and p-value <0.05, respectively.In total, 1232 differentially expressed transcripts were detected after 211At administration, demonstrating a profound effect on gene regulation. The number of regulated transcripts increased with higher initial dose-rate/absorbed dose at 1 or 6 h. However, the number of regulated transcripts decreased with mean absorbed dose/time after 1.7 kBq 211At administration. Furthermore, similar regulation profiles were seen for groups administered 1.7 kBq. Interestingly, few previously proposed radiation responsive genes were detected in the present study. Regulation of immunological processes were prevalent at 1, 6, and 168 h after 1.7 kBq administration (0.023, 0.32, 1.8 Gy.

  12. Qualitative ultrasound elastography assessment of benign thyroid nodules: Patterns and intra-observer acquisition variability

    International Nuclear Information System (INIS)

    Lacout, Alexis; Chevenet, Carole; Thariat, Juliette; Figl, Andrea; Marcy, Pierre-Yves

    2013-01-01

    To report and evaluate qualitative elastography patterns by using gray-scale and Doppler ultrasound (US) in patients presenting with benign thyroid nodules and to evaluate the reproducibility of US elastography examinations. Institutional review board approval was obtained, and all patients provided informed consent. Over a 3-month time period, all consecutive adult patients were referred to our institution to undergo a thyroid nodule fine-needle aspiration biopsy (FNAB) procedure. Patients presenting with benign cytology according to the Bethesda 2008 classification were prospectively enrolled in the study. Each thyroid nodule was assessed by using gray-scale, Doppler US, and elastography acquisitions by a single operator (A. L.). Multiple elastography acquisitions per thyroid nodule were performed and elastography scorings of the nodules were compared with each other. Nineteen patients (16 women and 3 men, mean age 58 years) with 22 thyroid nodules were included in the present study. Elastographic patterns 1, 2, and 3 were reported (23% nodules showed pattern 3). The elastography pattern showed a strong variability in 13 nodules (59%). The elastography acquisition result variability involved the “malignant” pattern 3 in 36% of cases. Almost one-third of benign thyroid nodules displayed pattern 3 on qualitative US elastography. The intra-observer variability of the benign thyroid elastography scoring is wide, thus limiting the thyroid nodule US examination accuracy. In FNAB-proven benign thyroid nodules, elastography pattern 3 is frequent and cannot be used as a strong indicator of thyroid malignancy

  13. Irrigation in dose assessments models

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla; Barkefors, Catarina [Studsvik RadWaste AB, Nykoeping (Sweden)

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  14. Irrigation in dose assessments models

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Barkefors, Catarina

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  15. Monte Carlo determination of dose in crystalline and thyroid during chest tomography examinations

    International Nuclear Information System (INIS)

    Quispe H, B.; Pena V, J. D.; Waldo B, G.; Leon M, M.; Ceron R, P.; Vallejo H, A.; Sosa A, M.; Vega C, H. R.

    2017-10-01

    Computed tomography is a diagnostic imaging method that deposits higher doses than other radio diagnosis methods. The knowledge of the spectrum of X-rays is important, since is in direct function with the dose absorbed by the patient. In this work we estimated the spectrum of X-rays, produced during the interaction of monoenergetic electrons of 130 KeV with Tungsten white, in order to determine their energetic characteristics at 50 cm from the focal point. The study was done using Monte Carlo methods with the code MCNP5 where the X-ray tube of a Siemens SOMATOM Perspective tomograph of the General Regional Hospital of Leon, Mexico was modeled. In the calculations, 3 x 10 8 stories were used and a relative uncertainty of less than 0.1% was obtained. Also, a neck manikin with thyroid, thorax and head that included the eye, the table and gantry with 70 cm opening of the tomography was modeled. The X-ray spectrum calculated with a cut thickness of 10 mm limited by Pb collimators was used as the source term. The radiological service routine scanning protocol was used for chest computed tomography; the step-by-step or instant trigger method was simulated by moving the manikin coordinates for each cut and 360 degree continuous rotation movement. 36 positions of the X-ray tube were used in steps of 10 degrees. The radiation dispersed in the thorax deposits a dose of 2.063 mGy in crystalline and 252 mGy in thyroid. (Author)

  16. Time-integrated thyroid dose for accidental releases from Pakistan Research Reactor-1

    International Nuclear Information System (INIS)

    Raza, S Shoaib; Iqbal, M; Salahuddin, A; Avila, R; Pervez, S

    2004-01-01

    The two-hourly time-integrated thyroid dose due to radio-iodines released to the atmosphere through the exhaust stack of Pakistan Research Reactor-1 (PARR-1), under accident conditions, has been calculated. A computer program, PAKRAD (which was developed under an IAEA research grant, PAK/RCA/8990), was used for the dose calculations. The sensitivity of the dose results to different exhaust flow rates and atmospheric stability classes was studied. The effect of assuming a constant activity concentration (as a function of time) within the containment air volume and an exponentially decreasing air concentration on the time-integrated dose was also studied for various flow rates (1000-50,000 m 3 h -1 ). The comparison indicated that the results were insensitive to the containment air exhaust rates up to or below 2000 m 3 h -1 , when the prediction with the constant activity concentration assumption was compared to an exponentially decreasing activity concentration model. The results also indicated that the plume touchdown distance increases with increasing atmospheric stability. (note)

  17. Exposure dose assessment using bioassay

    International Nuclear Information System (INIS)

    Suga, Shinichi

    1994-01-01

    Bioassay involves following steps: sampling, pre-treatment, chemical separation and counting of radioactivity. As bioassay samples, urines are usually used, although faecal analysis may be required in some occasions for example to assess intake of non-transferable radioactive materials. Nasal smear is a useful indicator of an inhalation case. Exhalation air is used to estimate the intake of tritiated water. Sample pre-treatment includes evaporation for concentration, wet ashing, dry ashing and co-precipitation. After adding small amount of nitric acid, the sample can be concentrated by 1/10 of initial volume, which may be used to identify γ-emitters. As the pre-treatment of urine, wet ashing is used for example for analysis of Pu, and co-precipitation is used for example for analysis of Sr. Dry ashing by electric furnace is usually adopted for faecal samples. Methods of chemical separation depend on the radionuclide(s) to be analysed. The detection limit depends also on radionuclide, and for example typical detection limits are 0.4Bq / l (volume of urine sample) for 89 Sr or 90 Sr, and 0.01 Bq / l with urine and 0.01 Bq per sample with faeces for 238 Pu, 239 Pu or 241 Am. Simpler methods can be used for some radionuclides: For example, radioactivity concentration of tritium can be determined by liquid scintillation counting of urine or condensed water from exhaled air, and natural uranium in urine can be quantified by using fluorometric method. In some circumstances, gross-α or gross-β analyses are useful for quick estimation. To estimate intakes by inhalation or by ingestion from bioassay results and to assess the committed dose equivalent, commonly available bases are the relevant publications by the ICRP and domestic guides and manuals that conform to the radiation protection regulations. (author)

  18. Thyroid Histopathology Assessments for the Amphibian Metamorphosis Assay to Detect Thyroid-active Substances

    Science.gov (United States)

    In support of an Organization for Economic Cooperation and Development (OECD) Amphibian Metamorphosis Assay (AMA) Test Guideline for the detection of substances that interact with the hypothalamic-pituitary-thyroid axis, a document was developed that provides a standardized appro...

  19. An estimate by two methods of thyroid absorbed doses due to BRAVO fallout in several Northern Marshall Islands.

    Science.gov (United States)

    Musolino, S V; Greenhouse, N A; Hull, A P

    1997-10-01

    Estimates of the thyroid absorbed doses due to fallout originating from the 1 March 1954 BRAVO thermonuclear test on Bikini Atoll have been made for several inhabited locations in the Northern Marshall Islands. Rongelap, Utirik, Rongerik and Ailinginae Atolls were also inhabited on 1 March 1954, where retrospective thyroid absorbed doses have previously been reconstructed. The current estimates are based primarily on external exposure data, which were recorded shortly after each nuclear test in the Castle Series, and secondarily on soil concentrations of 137Cs in samples collected in 1978 and 1988, along with aerial monitoring done in 1978. The external exposures and 137Cs soil concentrations were representative of the atmospheric transport and deposition patterns of the entire Castle Series tests and show that the BRAVO test was the major contributor to fallout exposure during the Castle series and other test series which were carried out in the Marshall Islands. These data have been used as surrogates for fission product radioiodines and telluriums in order to estimate the range of thyroid absorbed doses that may have occurred throughout the Marshall Islands. Dosimetry based on these two sets of estimates agreed within a factor of 4 at the locations where BRAVO was the dominant contributor to the total exposure and deposition. Both methods indicate that thyroid absorbed doses in the range of 1 Gy (100 rad) may have been incurred in some of the northern locations, whereas the doses at southern locations did not significantly exceed levels comparable to those from worldwide fallout. The results of these estimates indicate that a systematic medical survey for thyroid disease should be conducted, and that a more definitive dose reconstruction should be made for all the populated atolls and islands in the Northern Marshall Islands beyond Rongelap, Utirik, Rongerik and Ailinginae, which were significantly contaminated by BRAVO fallout.

  20. An estimate by two methods of thyroid absorbed doses due to BRAVO fallout in several northern Marshall Islands

    International Nuclear Information System (INIS)

    Musolino, S.V.; Hull, A.P.; Greenhouse, N.A.

    1997-01-01

    Estimates of the thyroid absorbed doses due to fallout originating from the 1 March 1954 BRAVO thermonuclear test on Bikini Atoll have been made for several inhabited locations in the Northern Marshall Islands. Rongelap, Utirik, Rongerik and Ailinginae Atolls were also inhabited on 1 March 1954, where retrospective thyroid absorbed doses have previously been reconstructed. Current estimates are based primarily on external exposure data, which were recorded shortly after each nuclear test in the Castle Series, and secondarily on soil concentrations of 137 Cs in samples collected in 1978 and 1988, along with aerial monitoring done in 1978. External exposures and 137 Cs Soil concentrations were representative of the atmospheric transport and deposition patterns of the entire Castle Series tests and show that the BRAVO test was the major contributor to fallout exposure during the Castle series and other test series which were carried out in the Marshall Islands. These data have been used as surrogates for fission product radioiodines and telluriums in order to estimate the range of thyroid absorbed doses that may have occurred throughout the Marshall Islands. Dosimetry based on these two sets of estimates agreed within a factor of 4 at the locations where BRAVO was the dominant contributor to the total exposure and deposition. Both methods indicate that thyroid absorbed doses in the range of 1 Gy (100 rad) may have been incurred in some of the northern locations, whereas the doses at southern locations did not significantly exceed levels comparable to those from worldwide fallout. The results of these estimates indicate that a systematic medical survey for thyroid disease should be conducted, and that a more definitive dose reconstruction should be made for all the populated atolls and islands in the Northern Marshall Islands beyond Rongelap, Utirik, Rongerik and Ailinginae, which were significantly contaminated by BRAVO fallout. 30 refs., 2 figs., 10 tabs

  1. Radiation dose to the thyroid due to incorporation of iodine isotopes: Age dependence and reliability of dose factors

    International Nuclear Information System (INIS)

    Henrichs, K.; Mueller-Brunecker, G.; Paretzke, H.G.

    1983-08-01

    This is the first time that dose factors are published in the literature, together with an assessment of their reliability with regard to the quantification of the dose received by the population in the Federal Republic of Germany due to incorporation if iodine isotopes, taking into account the given age distribution among the population. The calculation of dose factors is based on the latest dosimetric and metabolic models issued by the ICRP (ICRP-30), and the impact of the various parameters and their variability on the accuracy of dose factor determination is assessed. The procedure followed to calculate the dose due to incorporation on the basis of metabolic models (ICRP 1978 and ICRP 1979) is explained. The main data (such as half life, mean frequency per decay, mean energy in keV) are given for I-123, I-125, I-129, I-131, I-132, I-133, I-134, and I-135 (ICRP-30) and listed in tables. (orig./HP) [de

  2. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  3. Age- and sex-specific estimation of dose to a normal thyroid from clinical administration of iodine-131

    International Nuclear Information System (INIS)

    Killough, G.G.; Eckerman, K.F.

    1986-09-01

    This report describes the derivation of an age- and sex-dependent model of radioiodine dosimetry in the thyroid and the application of the model to estimating the thyroid dose for each of 4215 patients who were exposed to 131 I in diagnostic and therapeutic procedures. In most cases, the data available consisted of the patient's age at the time of administration, the patient's sex, the quantity of activity administered, the clinically determined uptake of radioiodine by the thyroid, and the time after administration at which the uptake was determined. The model was made to conform to these data requirements by the use of age-specific estimates of the biological half-time of iodine in the thyroid and an age- and sex-dependent representation of the mass of the thyroid. Also, it was assumed that the thyroid burden was maximum at 24 hours after administration (the 131 I dose is not critically sensitive to this assumption). The metabolic model is of the form A(t) = K x (exp(-μ 1 t) - exp(-μ 2 t)) μCi where μ/sub i/ = λ/sub r/ + λ/sub i//sup b/ (i = 1, 2), λ/sub r/ is the radiological decay-rate coefficient, and the λ/sub i//sup b/ are biological removal-rate coefficients. The values of λ/sub i//sup b/ are determined by solving a nonlinear equation that depends on assumptions about the time of maximum uptake and the eventual biological loss rate (through which age dependence enters). An addendum (Appendix C) extends the method to other radioiodines and gives age- and sex-dependent dose conversion factors for most isotopes

  4. Uncertainties in individual doses in a case-control study of thyroid cancer after the Chernobyl accident

    International Nuclear Information System (INIS)

    Drozdovitch, V.; Maceika, E.; Khrouch, V.; Zvonova, I.; Vlasov, O.; Bouville, A.; Cardis, E.

    2007-01-01

    Individual radiation doses to the thyroid were reconstructed for 2239 subjects of a case-control study of thyroid cancer among young people that was carried out in regions of Belarus and Russia contaminated by radioactive fallout from the Chernobyl accident. Although the process of dose reconstruction provides a point estimate of each subject's dose, it is obvious that there is uncertainty associated with these dose calculations. The following main sources of uncertainty in the estimated individual doses were identified: (1) shared and un-shared errors associated with parameters of the dosimetry model; and (2) un-shared errors that are associated with the variability, reliability and ability of information from the personal interviews. Besides setting up proper distributions for the parameters of the dosimetry model, inter-individual correlations were also defined to take into account shared errors. By the application of Monte Carlo simulations, a set of approximately log-normally distributed thyroid doses was obtained for each subject; the geometric standard deviations of the distributions are found to vary among individuals from 1.7 to 3.7. (authors)

  5. Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine

    International Nuclear Information System (INIS)

    Sierralta, M.P.; Lillo, R.; Massardo, T.; Jofre, M.J.

    2002-01-01

    Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine. Introduction: The coadyuvant treatment with 131 I had proven to be useful in patients with differentiated thyroid carcinoma (DTC). Due to the physical characteristics of this radioisotope these patients must be absolutely isolated in order to reduce the radioactive exposure to other individuals. The aim of the study was to determine the time required to reach the maximum permissible radiation exposure level (0,25mR/h) to general public. Material between August 1999 and May 2000, 30 patients with DTC diagnosis in the University of Chile Clinical Hospital Nuclear Medicine Centre were studied, 25 women (83%) and 5 men (17%), mean age 45 years old (15-71 range). Tumoral histology was 86% papillary and 14% follicular types. Thirty one doses of 131 I were administered ( one patient received 2 doses): 24 of 100 mCi (77%), 5 of 150 mCi (16%) and 2 of 200 mCi (7%); afterwards the 1 m exposition rate in air was measured at neck level with a Geiger-Mueller detector. The procedure was repeated on day 4 and every day following until the predicted radiation exposure levels were reached. Results: The average exposure rate at day 0 ( after given the radiopharmaceutical) was 20,12 mR/h (4-32 range). At day 4 the average rate was 0,21 mR/h (0,08-0,34 ), and 61% (n=19) of the patients reached 0,25 mR/h within that day. On day 5 10% (n=3) reached 0,25 mR/h (0,25-0,26), on day 6 16% (n=5) reached 0,25 mR/h (0,2-0,28), on day 7 6% (n=2) reached 0,39 mR/h (0,25-0,48) and the remaining 7% on day 13 and day 17 (n=2). Conclusion After a treatment dose of 131 iodine over 60% of the cases can finish the isolation on day 4, and 90% on day 7. The measurement of 131 I uptake after 24 hours will help to determine the evolution of post treatment levels

  6. Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, M P [University of Chile Clinical Hospital Nuclear Medicine Centre, Santiago (Chile); Military Hospital Nuclear Medicine Department , Santiago (Chile); Lillo, R; Massardo, T [University of Chile Clinical Hospital Nuclear Medicine Centre, Santiago (Chile); Jofre, M J [Military Hospital Nuclear Medicine Department, Santiago (Chile)

    2002-09-01

    Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine. Introduction: The coadyuvant treatment with 131 I had proven to be useful in patients with differentiated thyroid carcinoma (DTC). Due to the physical characteristics of this radioisotope these patients must be absolutely isolated in order to reduce the radioactive exposure to other individuals. The aim of the study was to determine the time required to reach the maximum permissible radiation exposure level (0,25mR/h) to general public. Material between August 1999 and May 2000, 30 patients with DTC diagnosis in the University of Chile Clinical Hospital Nuclear Medicine Centre were studied, 25 women (83%) and 5 men (17%), mean age 45 years old (15-71 range). Tumoral histology was 86% papillary and 14% follicular types. Thirty one doses of 131 I were administered ( one patient received 2 doses): 24 of 100 mCi (77%), 5 of 150 mCi (16%) and 2 of 200 mCi (7%); afterwards the 1 m exposition rate in air was measured at neck level with a Geiger-Mueller detector. The procedure was repeated on day 4 and every day following until the predicted radiation exposure levels were reached. Results: The average exposure rate at day 0 ( after given the radiopharmaceutical) was 20,12 mR/h (4-32 range). At day 4 the average rate was 0,21 mR/h (0,08-0,34 ), and 61% (n=19) of the patients reached 0,25 mR/h within that day. On day 5 10% (n=3) reached 0,25 mR/h (0,25-0,26), on day 6 16% (n=5) reached 0,25 mR/h (0,2-0,28), on day 7 6% (n=2) reached 0,39 mR/h (0,25-0,48) and the remaining 7% on day 13 and day 17 (n=2). Conclusion After a treatment dose of 131 iodine over 60% of the cases can finish the isolation on day 4, and 90% on day 7. The measurement of 131 I uptake after 24 hours will help to determine the evolution of post treatment levels.

  7. AGING FACILITY WORKER DOSE ASSESSMENT

    International Nuclear Information System (INIS)

    R.L. Thacker

    2005-01-01

    The purpose of this calculation is to estimate radiation doses received by personnel working in the Aging Facility performing operations to transfer aging casks to the aging pads for thermal and logistical management, stage empty aging casks, and retrieve aging casks from the aging pads for further processing in other site facilities. Doses received by workers due to aging cask surveillance and maintenance operations are also included. The specific scope of work contained in this calculation covers both collective doses and individual worker group doses on an annual basis, and includes the contributions due to external and internal radiation from normal operation. There are no Category 1 event sequences associated with the Aging Facility (BSC 2004 [DIRS 167268], Section 7.2.1). The results of this calculation will be used to support the design of the Aging Facility and to provide occupational dose estimates for the License Application. The calculations contained in this document were developed by Environmental and Nuclear Engineering of the Design and Engineering Organization and are intended solely for the use of the Design and Engineering Organization in its work regarding facility operation. Yucca Mountain Project personnel from the Environmental and Nuclear Engineering should be consulted before use of the calculations for purposes other than those stated herein or use by individuals other than authorized personnel in Environmental and Nuclear Engineering

  8. Howard Hughes Medical Institute dose assessment survey

    International Nuclear Information System (INIS)

    O'Brien, S.L.; McDougall, M.M.; Barkley, W.E.

    1996-01-01

    Biomedical science researchers often express frustration that health physics practices vary widely between individual institutions. A survey examining both internal and external dose assessment practices was devised and mailed to fifty institutions supporting biomedical science research. The results indicate that health physics dose assessment practices and policies are highly variable. Factors which may contribute to the degree of variation are discussed. 2 tabs

  9. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    International Nuclear Information System (INIS)

    Stranden, E.; Widmark, A.; Sekse, T.

    2008-01-01

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  10. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    Energy Technology Data Exchange (ETDEWEB)

    Stranden, E.; Widmark, A.; Sekse, T. (Buskerud Univ. College, Drammen (Norway))

    2008-05-15

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  11. Parathyroid changes after high dose radioactive iodine in patients with thyroid cancer

    International Nuclear Information System (INIS)

    Guven, A.; Salman, S.; Boztepe, H.; Yarman, S.; Tanakol, R.; Azizlerli, H.; Alagol, F.

    2009-01-01

    The study aimed to investigate the effect of high dose radioactive iodine (RAI) on parathyroid function in patients with differentiated thyroid cancer. Nineteen patients (8 men/11 women, age 46.5±13.2 years) undergoing RAI for thyroid remnant ablation were enrolled in the study. The biochemical parameters related to parathyroid function [serum calcium (Ca), phosphate (P), creatinine (Cr), alkaline phosphatase (ALP), intact parathyroid hormone (iPTH), urinary Ca, cAMP concentrations and the maximum tubular capacity for phosphate per unit volume of glomerular filtrate (TmP/GFR)] were evaluated at baseline and at the 1st, 3rd, 6th and 12th months of RAI administration. SPSS 15.0 was used for statistical analysis. For all patients, thyroid-stimulating hormone levels were >30 U/ml at baseline and <0.1 U/ml at the following visits. Serum iPTH levels were decreased significantly at the 6th month and reached basal levels at the 12th month (baseline vs. 6th p=0.027, 1st vs. 6th p=0.011, 3rd vs. 6th p=0.047, 3rd vs. 12th p=0.014, 6th vs. 12th p=0.001). At the 6th month, P and TmP/GFR levels were higher (p=0.036, 0.017, respectively), and urinary cAMP measurements were lower (p=0.020) compared to those of the 1st month. No difference was detected concerning the other parameters. Serum Ca levels decreased below 2.1 mmol/l in several patients (n=5 at 1st month, n=4 at 3rd month, n=8 at 6th month and n=3 at 12th month) without clinical symptoms. The study indicated a transient decline in PTH levels at the 6th month following RAI therapy. Although this decrease did not cause symptoms in any of the present cases, this pattern might be important especially in individuals with diminished parathyroid background. (author)

  12. Quantitative global sensitivity analysis of a biologically based dose-response pregnancy model for the thyroid endocrine system.

    Science.gov (United States)

    Lumen, Annie; McNally, Kevin; George, Nysia; Fisher, Jeffrey W; Loizou, George D

    2015-01-01

    A deterministic biologically based dose-response model for the thyroidal system in a near-term pregnant woman and the fetus was recently developed to evaluate quantitatively thyroid hormone perturbations. The current work focuses on conducting a quantitative global sensitivity analysis on this complex model to identify and characterize the sources and contributions of uncertainties in the predicted model output. The workflow and methodologies suitable for computationally expensive models, such as the Morris screening method and Gaussian Emulation processes, were used for the implementation of the global sensitivity analysis. Sensitivity indices, such as main, total and interaction effects, were computed for a screened set of the total thyroidal system descriptive model input parameters. Furthermore, a narrower sub-set of the most influential parameters affecting the model output of maternal thyroid hormone levels were identified in addition to the characterization of their overall and pair-wise parameter interaction quotients. The characteristic trends of influence in model output for each of these individual model input parameters over their plausible ranges were elucidated using Gaussian Emulation processes. Through global sensitivity analysis we have gained a better understanding of the model behavior and performance beyond the domains of observation by the simultaneous variation in model inputs over their range of plausible uncertainties. The sensitivity analysis helped identify parameters that determine the driving mechanisms of the maternal and fetal iodide kinetics, thyroid function and their interactions, and contributed to an improved understanding of the system modeled. We have thus demonstrated the use and application of global sensitivity analysis for a biologically based dose-response model for sensitive life-stages such as pregnancy that provides richer information on the model and the thyroidal system modeled compared to local sensitivity analysis.

  13. Quantitative global sensitivity analysis of a biologically based dose-response pregnancy model for the thyroid endocrine system

    Directory of Open Access Journals (Sweden)

    Annie eLumen

    2015-05-01

    Full Text Available A deterministic biologically based dose-response model for the thyroidal system in a near-term pregnant woman and the fetus was recently developed to evaluate quantitatively thyroid hormone perturbations. The current work focuses on conducting a quantitative global sensitivity analysis on this complex model to identify and characterize the sources and contributions of uncertainties in the predicted model output. The workflow and methodologies suitable for computationally expensive models, such as the Morris screening method and Gaussian Emulation processes, were used for the implementation of the global sensitivity analysis. Sensitivity indices, such as main, total and interaction effects, were computed for a screened set of the total thyroidal system descriptive model input parameters. Furthermore, a narrower sub-set of the most influential parameters affecting the model output of maternal thyroid hormone levels were identified in addition to the characterization of their overall and pair-wise parameter interaction quotients. The characteristic trends of influence in model output for each of these individual model input parameters over their plausible ranges were elucidated using Gaussian Emulation processes. Through global sensitivity analysis we have gained a better understanding of the model behavior and performance beyond the domains of observation by the simultaneous variation in model inputs over their range of plausible uncertainties. The sensitivity analysis helped identify parameters that determine the driving mechanisms of the maternal and fetal iodide kinetics, thyroid function and their interactions, and contributed to an improved understanding of the system modeled. We have thus demonstrated the use and application of global sensitivity analysis for a biologically based dose-response model for sensitive life-stages such as pregnancy that provides richer information on the model and the thyroidal system modeled compared to local

  14. Side effects of rational dose iodine-131 therapy for metastatic well-differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Van Nostrand, D.; Neutze, J.; Atkins, F.

    1986-01-01

    Benua, Leeper, and others (BEL) have advocated the estimation of radiation exposure to the blood to select a more rational maximum safe dose of radioiodine (dosimetry) to treat metastatic functioning well-differentiated thyroid carcinoma. After adopting the BEL dosimetry approach, we reviewed the immediate (during hospitalization) and intermediate (from discharge up to 3 mo) side effects after our initial 15 therapies in ten patients. The doses ranged from 51 mCi (1887 MBq) to 450 mCi (16.65 GBq). Immediate side effects were observed in 12/15 (80%), are described in detail, and were as follows: gastrointestinal 10/15, salivary 9/15, nonsalivary neck pain, swelling, etc. 2/15, pulmonary 0/15. Intermediate side effects were observed in 10/15 (67%), are described in detail, and were as follows: gastrointestinal 0/15, salivary 3/15, nonsalivary neck pain, swelling, etc. 3/15, nasal complaints 2/15, transient bone marrow suppression 9/10, pulmonary 0/15. No patient required blood transfusions or had complications secondary to reduced blood counts. All patient complaints resolved; however, several patients may have reduced baseline blood counts one year after therapy. No other long-term side effect has been noted but the mean follow-up has been only 15 mo. In our opinion, we have not observed any side effect to date which would contraindicate the continued use and evaluation of the BEL dosimetry approach

  15. Side effects of rational dose iodine-131 therapy for metastatic well-differentiated thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Van Nostrand, D.; Neutze, J.; Atkins, F.

    1986-10-01

    Benua, Leeper, and others (BEL) have advocated the estimation of radiation exposure to the blood to select a more rational maximum safe dose of radioiodine (dosimetry) to treat metastatic functioning well-differentiated thyroid carcinoma. After adopting the BEL dosimetry approach, we reviewed the immediate (during hospitalization) and intermediate (from discharge up to 3 mo) side effects after our initial 15 therapies in ten patients. The doses ranged from 51 mCi (1887 MBq) to 450 mCi (16.65 GBq). Immediate side effects were observed in 12/15 (80%), are described in detail, and were as follows: gastrointestinal 10/15, salivary 9/15, nonsalivary neck pain, swelling, etc. 2/15, pulmonary 0/15. Intermediate side effects were observed in 10/15 (67%), are described in detail, and were as follows: gastrointestinal 0/15, salivary 3/15, nonsalivary neck pain, swelling, etc. 3/15, nasal complaints 2/15, transient bone marrow suppression 9/10, pulmonary 0/15. No patient required blood transfusions or had complications secondary to reduced blood counts. All patient complaints resolved; however, several patients may have reduced baseline blood counts one year after therapy. No other long-term side effect has been noted but the mean follow-up has been only 15 mo. In our opinion, we have not observed any side effect to date which would contraindicate the continued use and evaluation of the BEL dosimetry approach.

  16. Diagnostic I-131 scintigraphy in patients with differentiated thyroid cancer. No additional value of higher scan dose

    International Nuclear Information System (INIS)

    Phan, T.T.H.; Tol, K.M. van; Links, T.P.; Piers, D.A.; Vries, E.G.E. de; Dullaart, R.P.F.; Jager, P.L.

    2004-01-01

    After initial treatment with total thyroidectomy and radio iodine ablation, most follow-up protocols for patients with differentiated thyroid carcinoma contain cyclic diagnostic I-131 imaging and serum thyroglobulin (Tg) measurements. The applied diagnostic I-131 doses vary between 37 and 370 MBq. The aim of this study was to determine the yield of a diagnostic scan with 370 MBq I-131 in patients with a negative diagnostic scan with 74 MBq I-131. Retrospective evaluation of 158 patients who received a high-dose diagnostic scan with 370 MBq I-131 because of a negative low-dose diagnostic scan with 74 MBq I-131. Special attention was paid to the patients with positive high-dose diagnostic scanning and undetectable serum Tg levels after thyroid hormone withdrawal. In 127 (80%) of patients the 370 MBq I-131 scan was negative, just like the preceding low-dose scan. In 31 (20%) of patients abnormal uptake was present on the 370 MBq diagnostic scan. In 19 of these 31 patients serum Tg was undetectable. In 15/19 the high-dose diagnostic scan proved either false positive or demonstrated clinically irrelevant minor ablation rests. In only four patients (2.5%) did the high-dose diagnostic scans reveal possibly relevant uptake caused by residual differentiated thyroid cancer. In 98% of patients a 370 MBq dose of I-131 for diagnostic whole-body scintigraphy (WBS) had no additional value. The combination of a low-dose diagnostic I-131 scan using only 74 MBq combined with a serum Tg level measurement proved sufficient for correct clinical decision making regarding whether the patient requires additional I-131 therapy. (authors)

  17. Dose assessment models. Annex A

    International Nuclear Information System (INIS)

    1982-01-01

    The models presented in this chapter have been separated into 2 general categories: environmental transport models which describe the movement of radioactive materials through all sectors of the environment after their release, and dosimetric models to calculate the absorbed dose following an intake of radioactive materials or exposure to external irradiation. Various sections of this chapter also deal with atmospheric transport models, terrestrial models, and aquatic models.

  18. Thyroid cancer in Belarus after the Chernobyl accident: Incidence, prognosis of progress, risk assessment

    International Nuclear Information System (INIS)

    Buglova, E.; Kenigsberg, J.; Golovneva, A.; Demidchik, E.

    1997-01-01

    Starting from 1990, an increasing number of persons, suffering from thyroid cancer was diagnosed in Belarus. These persons were exposed to radiation in 1986 due to the Chernobyl Accident and were children and adolescents at the time of the accident. This paper gives an overview of the total number of thyroid cancer cases observed in Belarus after the Chernobyl accident among the persons exposed to radiation under 18 years of age. Duration of the latent period and background incidence rate are under discussion. Based on the most reliable data about thyroid doses and incidence rate among the persons exposed to radiation under 6 years of age, the estimation of risk coefficient for radiation induced thyroid cancer was carried out. For childhood exposure from I-131, the excess absolute risk per 10,0000 PYGy was 4.5 (author)

  19. Reconstruction of dose loads on population in the initial period of the Chernobyl accident and estimation of thyroid cancer risk in Belarus

    International Nuclear Information System (INIS)

    Krivoruchko, K.; Naumov, A.

    1997-01-01

    The Chernobyl accident caused significant long-term consequences to the environment, public health, and economic status of Belarus. The contamination from short-lived radionuclides, in particular iodine 131, was so high that the subsequent exposure of millions of people has been termed 'iodine shock'. During the first days of the accident, the majority of the dose of radiation received by the residents of Belarus was to the thyroid gland. This will affect the health of the population for a long time to come. The resulting epidemic of childhood thyroid cancer is the first indisputable health after-effect of the Chernobyl accident. Thyroid cancer morbidity among children increased more than 10 fold in the post-Chernobyl period. Maps of cesium 137, which has a half life of 37 years, have been published, but it is evident, that the distribution of thyroid cancer morbidity differs from the known distribution of cesium 137 in soil. Territorial distribution of thyroid cancer morbidity is often compared to distribution of cesium 137 in the soil. This practice is inaccurate but often utilized since no maps of iodine 131 contamination exist, due to its short half life of 8.04 days. Reconstruction of the spatial distribution of short-lived isotopes in the first days after the accident, could clarify the impact of radiation on human health and allow for a spatial and temporal prognosis of the development of the cancer epidemic, particularly, thyroid cancer. Due to the unfortunate fact that the measuring equipment was inadequate to properly monitor the scale of radiation exposure during the early period of the accident, detailed direct information on the deposition of the short-lived radionuclides and the doses to the population has been irretrievably lost. Now the only way to reconstruct the dynamics of the radioecological situation of the initial period of the Chernobyl accident is to make a retrospective assessment of radiation exposures related to the short

  20. The thyroid nodule. Thyrotropin and peripheral thyroid hormones; Der Schilddruesenknoten. TSH und periphere Hormone

    Energy Technology Data Exchange (ETDEWEB)

    Zimny, M. [Klinikum Hanau (Germany). Inst. fuer Nuklearmedizin

    2008-09-15

    Thyrotropin, free triodothyronine and thyroxine represent the standard serological parameters for the diagnostic work-up of the thyroid but only a minority of thyroid nodules present with subclinical or overt thyroid disorders. Besides a review of the regulation and principle of function of thyroid hormones as well as the effects of subclinical or overt hyperthyroidism, the significant role of these parameters beyond the assessment of hyperthyroidism in thyroid nodules is discussed. There is evidence that the level of thyrotropin within the normal range is predictive for the relevance of autonomous functioning nodules and the risk of malignancy of non-functioning thyroid nodules. Furthermore, the ratio of triodothyronine and thyroxine indicates the etiology of hyperthyroidism. Thyrotropin represents the main parameter to determine the adequate dose of thyroid hormone therapy of thyroid nodules. (orig.)

  1. First results of radioiodine therapy of multifocal and disseminated functional thyroid autonomy using a TcTUs-adapted dose concept

    International Nuclear Information System (INIS)

    Oexle, C.; Reinhardt, M.; Moser, E.

    1998-01-01

    Aim: The presented study examines prospectively the efficiency of a dose concept for radioiodine therapy (RIT) adapted to the pretherapeutic 99m Tc-pertechnetate thyroid uptake under suppression (TcTU s ) in patients with multifocal (MFA) and disseminated (DISA) autonomy. This concept considers the total thyroid as target volume and uses target doses from 150 Gy to 300 Gy according to the TcTU s , which is as a measure for the 'autonomous volume' of the thyroid. Methods: The data of 75 patients (54 female, 21 male; age 71±9 years) with MFA or DISA were evaluated. RIT was performed on patients presenting with normal values for free triiodothyronine and thyroxine and endogenous suppression of the basal thyrotropin (TSH). The following target doses were used: For a TcTU s of 1,5-2,5% 150 Gy, for 2,51-3,5% 200 Gy, for 3,51-4,5% 250 Gy, and for >4,5% 300 Gy. The radiation dose to be administered was calculated using a modified Marinelli formula. The therapy was considered as successful when the basal TSH was above 0,5 mU/l and autonomous areas had disapeared in thyroid scintigraphy or the TcTU was below 1,5%, respectively. The average follow-up period was 8±4 months. Results: The success rates average to 92%. Only in one case a subsequent subclinical hypothyroidism and in a further case an immunogenic hyperthyroidism occured. Conclusion: The presented data indicate, that even patients with a marked autonomy (TcTU s >3,5%) can thus expected to be cured by of a onetime therapy with success rate of over 90% using the presented dose concept. The rate of early hypothyroidism can alltogether be estimated as very low. (orig.) [de

  2. Nuclear medicine in the assessment of differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Rutherford, G.-C.; Franc, B.; O'Connor, A.

    2008-01-01

    Despite modern multi-modality treatment, 10-30% of patients treated for differentiated thyroid cancer (DTC) ultimately develop local recurrence or metastatic disease. These malignancies are frequently slow-growing and secondary surgical resection is often undertaken along with radioactive iodine treatment. Correlation of radiological imaging with nuclear medicine studies is essential for individualized treatment planning, and to optimize this management. Radiologists should be familiar with the interpretation of various nuclear medicine studies used to image differentiated thyroid neoplasms

  3. Absorbed dose calculation from beta and gamma rays of 131I in ellipsoidal thyroid and other organs of neck with MCNPX code

    Directory of Open Access Journals (Sweden)

    Mohammad Mirzaie

    2012-09-01

    Full Text Available Background: The 131I radioisotope is used for diagnosis and treatment of hyperthyroidism and thyroid cancer. In optimized Iodine therapy, a specific dose must be reached to the thyroid gland with minimum radiation to the cervical spine, cervical vertebrae, neck tissue, subcutaneous fat and skin. Dose measurement inside the alive organ is difficult therefore the aim of this research was dose calculation in the organs by MCNPX code. Materials and Methods: First of all, the input file for MCNPX code has been prepared to calculate F6 and F8 tallies for ellipsoidal thyroid lobes with long axes is tow times of short axes which the 131I is distributed uniformly inside the lobes. Then the code has been run for F6 and F8 tallies for variation of lobe volume from 1 to 25 milliliters. From the output file of tally F6, the gamma absorbed dose in ellipsoidal thyroid, spinal neck, neck bone, neck tissue, subcutaneous fat layer and skin for the volume lobe variation from 1 ml to 25 ml have been derived and the graphs are drew. As well as, form the output of F8 tally the absorbed energy of beta in thyroid and soft tissue of neck is obtained and listed in the table and then absorbed dose of bate has been calculated. Results: The results of this research show that for constant activity in thyroid, the absorbed dose of gamma decreases about 88.3% in thyroid, 6.9% at soft tissue, 19.3% in adipose layer and 17.4% in skin, but it increases 32.1% in spinal of neck and 32.3% in neck bone when the lobe volume varied from 1 to 25 milliliters. For the same situation, the beta absorbed dose decreases 95.9% in thyroid and 64.2% in soft tissue. Conclusion: For the constant activity in thyroid by increasing the thyroid volume, absorbed dose of gamma in thyroid and soft tissue of neck, adipose layer under the skin and skin of neck decreased, but it increased at spinal of neck and neck bone. Also, by increasing of the lobe volume in constant activity, the beta absorbed dose

  4. Research and assessment of national population dose

    International Nuclear Information System (INIS)

    Pan Ziqiang

    1984-01-01

    This article describes the necessity and probability of making researches on assessment of national population dose, and discusses some problems which might be noticeable in the research work. (author)

  5. Calculational Tool for Skin Contamination Dose Assessment

    CERN Document Server

    Hill, R L

    2002-01-01

    Spreadsheet calculational tool was developed to automate the calculations preformed for dose assessment of skin contamination. This document reports on the design and testing of the spreadsheet calculational tool.

  6. Thermoluminescent dosimetry and assessment of personal dose

    International Nuclear Information System (INIS)

    Boas, J.F.; Martin, L.J.; Young, J.G.

    1982-01-01

    Thermoluminescence is discussed in terms of the energy band structure of a crystalline solid and the trapping of charge carriers by point defects. Some general properties of thermoluminescent materials used for dosimetry are outlined, with thermoluminescence of CaSO 4 :Dy being described in detail. The energy response function and the modification of the energy response of a dosimeter by shielding are discussed. The final section covers the connection between exposure, as recorded by a TLD badge, and the absorbed dose to various organs from gamma radiation in a uranium mine; the conversion from absorbed dose to dose equivalent; and uncertainties in assessment of dose equivalent

  7. Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol.2

    International Nuclear Information System (INIS)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines. In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios

  8. Thyroid diseases

    International Nuclear Information System (INIS)

    Noma, Koji

    1992-01-01

    This chapter reviews the correlation between thyroid disease, other than cancer, and radiation in the literature. Radiation-induced thyroid disturbance is discussed in the context of external and internal irradiation. External irradiation of 10 to 40 Gy may lower thyroid function several months or years later. Oral administration of I-131 is widely given to patients with Basedow's disease; it may also lower thyroid function with increasing radiation doses. When giving 70 Gy or more of I-131, hypothyroidism has been reported to occur in 20-30% and at least 10%. Thyroiditis induced with internal I-131 irradiation has also been reported, but no data is available concerning external irradiation-induced thyroiditis. The incidence of nodular goiter was found to be several ten times higher with external irradiation than internal irradiation. Thyroid disturbance is correlated with A-bomb survivors. A-bomb radiation can be divided into early radiation within one minute after A-bombing and the subsequent residual radiation. Nodular goiter was significantly more frequent in the exposed group than the non-exposed group; it increased with increasing radiation doses and younger age (20 years or less) at the time of exposure. The incidence of decrease in thyroid function was higher with increasing radiation doses. However, in the case of Nagasaki, the incidence of hypothyroidism was significantly higher in the low-dose exposed group, especially A-bomb survivors aged 10-39 at the time of exposure and women. (N.K.)

  9. An updated dose assessment for Rongelap Island

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W.L.; Conrado, C.L.; Bogen, K.T.

    1994-07-01

    We have updated the radiological dose assessment for Rongelap Island at Rongelap Atoll using data generated from field trips to the atoll during 1986 through 1993. The data base used for this dose assessment is ten fold greater than that available for the 1982 assessment. Details of each data base are presented along with details about the methods used to calculate the dose from each exposure pathway. The doses are calculated for a resettlement date of January 1, 1995. The maximum annual effective dose is 0.26 mSv y{sup {minus}1} (26 mrem y{sup {minus}1}). The estimated 30-, 50-, and 70-y integral effective doses are 0.0059 Sv (0.59 rem), 0.0082 Sv (0.82 rem), and 0.0097 Sv (0.97 rem), respectively. More than 95% of these estimated doses are due to 137-Cesium ({sup 137}Cs). About 1.5% of the estimated dose is contributed by 90-Strontium ({sup 90}Sr), and about the same amount each by 239+240-Plutonium ({sup 239+240}PU), and 241-Americium ({sup 241}Am).

  10. Radioiodine therapy of hyperfunctioning thyroid nodules: usefulness of an implemented dose calculation algorithm allowing reduction of radioiodine amount.

    Science.gov (United States)

    Schiavo, M; Bagnara, M C; Pomposelli, E; Altrinetti, V; Calamia, I; Camerieri, L; Giusti, M; Pesce, G; Reitano, C; Bagnasco, M; Caputo, M

    2013-09-01

    Radioiodine is a common option for treatment of hyperfunctioning thyroid nodules. Due to the expected selective radioiodine uptake by adenoma, relatively high "fixed" activities are often used. Alternatively, the activity is individually calculated upon the prescription of a fixed value of target absorbed dose. We evaluated the use of an algorithm for personalized radioiodine activity calculation, which allows as a rule the administration of lower radioiodine activities. Seventy-five patients with single hyperfunctioning thyroid nodule eligible for 131I treatment were studied. The activities of 131I to be administered were estimated by the method described by Traino et al. and developed for Graves'disease, assuming selective and homogeneous 131I uptake by adenoma. The method takes into account 131I uptake and its effective half-life, target (adenoma) volume and its expected volume reduction during treatment. A comparison with the activities calculated by other dosimetric protocols, and the "fixed" activity method was performed. 131I uptake was measured by external counting, thyroid nodule volume by ultrasonography, thyroid hormones and TSH by ELISA. Remission of hyperthyroidism was observed in all but one patient; volume reduction of adenoma was closely similar to that assumed by our model. Effective half-life was highly variable in different patients, and critically affected dose calculation. The administered activities were clearly lower with respect to "fixed" activities and other protocols' prescription. The proposed algorithm proved to be effective also for single hyperfunctioning thyroid nodule treatment and allowed a significant reduction of administered 131I activities, without loss of clinical efficacy.

  11. Skin entrance dose - thyroid: comparison between three kinds of dental appliances; Dose de entrada na pele - tireóide: comparativo entre três tipos de aparelhos odontológicos

    Energy Technology Data Exchange (ETDEWEB)

    Savi, M.; Viana, E.; Soares, F.A., E-mail: matheus.savi@ifsc.edu.br [Dept. Acadêmico de Saúde e Serviços/CST em Radiologia, Instituto Federal de Santa Catarina, Florianópolis (Brazil)

    2017-07-01

    Patient dosimetry is necessary to determine dosimetric quantities, establish reference levels for radio-diagnosis and assess health risks. Part of the radiation beam of the appliances that penetrates the patient's body is absorbed by tissues and part is spread and its sum is known as the Dose of Entrance into the Skin. The objective of this study is to know and compare the DEP of dental radiology devices in the thyroid gland. Two periapical, panoramic and computerized conical beam tomographs were used in this study at a private dentistry clinic and at the Federal Institute of Santa Catarina. The periapical apparatus produced the highest total dose of radiation, as well as a higher dose rate, followed by CBCT and panoramic.

  12. Milk production and distribution in low-dose counties for the Hanford Thyroid Disease Study

    International Nuclear Information System (INIS)

    Schimmel, J.G.

    1992-06-01

    This report identifies sources of milk consumed by residents of Ferry, Okanogan, and Stevens Counties. This information will be used by the Hanford thyroid Disease Study to determine whether thyroid disease has been increased among people exposed to past iodine--131 emissions from Hanford Site Facilities

  13. Scattered radiation dose to radiologist's cornea, thyroid and gonads while performing some x-ray fluoroscopic investigations

    International Nuclear Information System (INIS)

    Chougle, Arun

    1993-01-01

    The mankind has been immensely benefited from discovery of X-ray and it has found wide spread application in diagnosis and treatment. Radiation is harmful and can produce somatic and genetic effects in the exposed person. International Commission on Radiation Protection (ICRP) has recommended a system of dose limitation based on principle of ALARA. All the efforts should be made to keep the radiation dose to the radiation worker as low as possible. Fluoroscopy gives maximum dose to the patient and staff and hence we have attempted to quantify the scattered radiation dose to the cornea, thyroid and gonads of the radiologist performing fluoroscopic examinations such as barium meal, barium swallow, barium enema, myelography, histerosalpingography and fracture reduction. Thermoluminescence dosimetry (TLD) method using CaSO 4 :Dy TLD disc was employed for these measurements. Use of lead apron has reduced the dose to radiologist's gonad. (author). 3 refs., 4 tabs

  14. Neck and whole-body scanning with 5-mCi dose of (123)I as diagnostic tracer in patients with well-differentiated thyroid cancer.

    Science.gov (United States)

    Gulzar, Z; Jana, S; Young, I; Bukberg, P; Yen, V; Naddaf, S; Abdel-Dayem, H M

    2001-01-01

    To determine whether a 5-mCi dose of 123I can be used as an effective radiotracer for assessing the presence of remnant thyroid tissue and for searching for metastatic lesions in patients with well-differentiated thyroid cancer as well as to attempt to ascertain whether a scan performed only at 4 hours is sufficient for accurate diagnosis and might replace the conventional protocol of scanning at both 4 hours and 24 hours. We prospectively studied 27 patients who had undergone near-total thyroidectomy and had a documented diagnosis of well-differentiated thyroid carcinoma. Patients underwent scanning after receiving a 5-mCi dose of 123I, at a time when they had discontinued thyroid replacement therapy and had a thyrotropin level in excess of 30 mIU/mL. Whole-body images at 4 hours and 24 hours were obtained and were compared with posttherapy scans obtained 5 to 7 days after administration of 131I. Scans were interpreted by two board-certified nuclear medicine physicians. Of the 27 patients, 2 (7.4%) showed discordance between the 123I scan performed at 24 hours and the posttherapy 131I scan. When 4-hour images after administration of 123I were compared with the posttherapy 131I scans, a discordance rate of 14.8% (4 of 27 patients) was noted. In addition, two of these four patients showed lesions on the 24-hour images that were not seen on the 4-hour images (one with new lung metastatic involvement and the other with a local recurrence in the lower neck area). The prognosis and treatment of these two patients were substantially changed by the result of the 24-hour images. On comparison of scans obtained after administration of a 5-mCi dose of 123I with those obtained after 131I therapy, we conclude that 5 mCi of 123I produces images that have excellent quality and resolution and also compare favorably with those obtained after 131I therapy. Furthermore, a decrease in the dose of 123I from 10 mCi to 5 mCi lowered the cost of the study without compromising the

  15. [Surgical assessment of complications after thyroid gland operations].

    Science.gov (United States)

    Dralle, H

    2015-01-01

    The extent, magnitude and technical equipment used for thyroid surgery has changed considerably in Germany during the last decade. The number of thyroidectomies due to benign goiter have decreased while the extent of thyroidectomy, nowadays preferentially total thyroidectomy, has increased. Due to an increased awareness of surgical complications the number of malpractice claims is increasing. In contrast to surgical databases the frequency of complications in malpractice claims reflects the individual impact of complications on the quality of life. In contrast to surgical databases unilateral and bilateral vocal fold palsy are therefore at the forefront of malpractice claims. As guidelines are often not applicable for the individual surgical expert review, the question arises which are the relevant criteria for the professional expert witness assessing the severity of the individual complication. While in surgical databases major complications after thyroidectomy, such as vocal fold palsy, hypoparathyroidism, hemorrhage and infections are equally frequent (1-3 %), in malpractice claims vocal fold palsy is significantly more frequent (50 %) compared to hypoparathyroidism (15 %), hemorrhage and infections (about 5 % each). To avoid bilateral nerve palsy intraoperative nerve monitoring has become of utmost importance for surgical strategy and malpractice suits alike. For surgical expert review documentation of individual risk-oriented indications, the surgical approach and postoperative management are highly important. Guidelines only define the treatment corridors of good clinical practice. Surgical expert reviews in malpractice suits concerning quality of care and causality between surgical management, complications and sequelae of complications are therefore highly dependent on the grounds and documentation of risk-oriented indications for thyroidectomy, intraoperative and postoperative surgical management.

  16. Optimization of the therapeutic dose of {sup 131}I for thyroid differentiated carcinoma; Otimizacao da dose terapeutica com {sup 131}I para carcinoma diferenciado da tiroide

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Fabiana Farias de

    2002-09-01

    I-131 thyroid cancer therapy is based on the strategy of concentrating radioactive iodine in the thyroid tissue, to completetly eliminate thyroid tissue and functioning thyroid cancer metastases remaining after thyroidectomy. In Brazil, fixed activities of {sup 131} I generally are given, sometimes either delivering insufficient activities to ablate all of the remnants, or unnecessarily high activities, with patients remaining in the hospital for some period of time. This investigation proposes a protocol of individualized planning of ablative doses, based on individual patients metabolisms and measured thyroid remnant masses. Simulated thyroid remnants were fabricated in various forms, volumes and activities, and optimum image acquisition parameters were determined using Single-Photon Emission Computed Tomography 9SPECT). Resultant images were evaluated, to determine the apparent volumes and the {sup 131} I concentrations. I-131 metabolism was studied in 9 patients who had undergone thyroidectomies. Their thyroid remnant masses were determined applying the same parameters used in SPECT simulation studies, and the optimum activity for their therapy was calculated and compared to the established fixed activity of 3.7 GBq (100 mCi), which would have normally been assigned. Background subtraction using the method of percent maximum counts, using a value of 67.5%, combined with scatter correction (triple energy window method), was shown to be optimum for SPECT quantification of volumes between 3-10 ml. Errors in the method were below 9% for sources with regular geometries and around 11% for sources with irregular geometries. In the patient studies, it was observed that 78% of patients could have received reduced activities of {sup 131} (from 0.8-3-2. GBq (20-87 nCi). In addition, 33% of these patients could have received low enough activities to have discharged from the hospital, using an individualized administration scheme. This could also have resulted in a dose

  17. Thyroid cancer among children and adolescents in Russia following the Chernobyl accident. Retrospective estimation of thyroid doses and case - control study

    International Nuclear Information System (INIS)

    Ivanov, V.K.; Pitkevich, V.A.; Chekin, S.Yu.

    2000-01-01

    The first large-scale study of thyroid cancer among young people in Russia following the Chernobyl accident was conducted. The study population consists of all children and adolescents (17 years and less) who were resided in Kaluga, Orel and Tula oblasts of Russia at the time of Chernobyl accident. Kaluga, Orel and Tula oblasts are approximately equally contaminated oblasts of Russia (up to 15 Ci/km2 for cesium-137). All prevalent and new carcinoma cases from 1 January 1992 to 31 December 1998 were collected in 1997-1998 years as a result of joint project on thyroid disease conducted by the Medical Radiological Research Center (Russia), International Agency for Research on Cancer (France) and Sasakawa Memorial Health Foundation (Japan). Cases of thyroid cancer were found through the Russia National Medical and Dosimetric Registry and Russian Oncology Dispensaries. All cases were independently hystologically verified by the international panel of pathologists from Russia, Belarus and Europe. There were 12 cases in Kaluga, 27 cases in Orel and 23 cases in Tula oblasts. For each case were randomly selected two and four controls: two controls were matched on age, sex and on settlement of residence at the time of accident; four controls were matched on age, sex and on oblast of residence at the time of accident. Each patient and corresponding controls were examinated by the high-resolution ultrasonographic instrument and were interviewed by special trained medical staff. The new technique for reconstruction of the individual dose of internal irradiation of thyroid with incorporated 131 I was developed. The method allows to take into account major factors influencing formation thyroid doses of the population: (1) three sources of receipt 131 I in organism of the man: inhalation, consumption of milk and green vegetables; (2) types of food production: public and private (individual) sectors of its (her) manufacture; (3) weather conditions of spring of 1986 in regions of

  18. The significance of 1-131 scan dose in patients with thyroid cancer: determination of ablation: concise communication

    International Nuclear Information System (INIS)

    Waxman, A.; Ramanna, L.; Chapman, N.; Chapman, D.; Brachman, M.; Tanasescu, D.; Berman, D.; Catz, B.; Braunstein, G.

    1981-01-01

    Twenty-four patients with differentiated thyroid cancer were studied with diagnostic I-131 neck chest scans after having undergone bilateral subtotal thyroidectomy and initial I-131 therapy with either 30- or 100-mCi doses. With an endogenous stimulation protocol, follow-up studies were performed with neck and chest scans using 2 and 10 mCi I-131. A 400% increase in sensitivity was found with a 10-mCi dose relative to a 2-mCi dose. Comparison with therapeutic doses of 30 and 100 mCi resulted in further increases in the detection of residual iodine-avid tissue. We conclude that a 2-mCi or lower dose of I-131 is inadequate in evaluating residual iodine-avid tissue visually in patients with thyroid cancer. The study does not answer the critical question of whether it is necessary to treat a patient presenting a negative 2-mCi but a positive 10-mCi scan. It may be appropriate to define ablation visually as well as clinically, with further studies directed toward determining a treatment rationale in this patient population

  19. Dose assessment activities in the Republic of the Marshall Islands.

    Science.gov (United States)

    Simon, S L; Graham, J C

    1996-10-01

    Dose assessments, both retrospective and prospective, comprise one important function of a radiological study commissioned by the Republic of the Marshall Islands (RMI) government in late 1989. Estimating past or future exposure requires the synthesis of information from historical data, results from a recently completed field monitoring program, laboratory measurements, and some experimental studies. Most of the activities in the RMI to date have emphasized a pragmatic rather than theoretical approach. In particular, most of the recent effort has been expended on conducting an independent radiological monitoring program to determine the degree of deposition and the geographical extent of weapons test fallout over the nation. Contamination levels on 70% of the land mass of the Marshall Islands were unknown prior to 1994. The environmental radioactivity data play an integral role in both retrospective and prospective assessments. One recent use of dose assessment has been to interpret environmental measurements of radioactivity into annual doses that might be expected at every atoll. A second use for dose assessment has been to determine compliance with a dose action level for the rehabilitation of Rongelap Island. Careful examination of exposure pathways relevant to the island lifestyle has been necessary to accommodate these purposes. Examples of specific issues studied include defining traditional island diets as well as current day variations, sources of drinking water, uses of tropical plants including those consumed for food and for medicinal purposes, the nature and microvariability of plutonium particles in the soil and unusual pathways of exposure, e.g., that which might be associated with cooking and washing outdoors and inadvertent soil ingestion. A study on the prevalence of thyroid disease is also being conducted and the geographic pattern of disease may be useful as a bioindicator of the geographic pattern of exposure to radioiodine. Finally, an

  20. Determination of radiation dose rates and urinary activity of patients received Sodium Iodide-131 for treatment of differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Beiki, D.; Shahhosseini, S.; Dadashzadeh, S.; Eftekhari, M.; Tayebi, H.; Moosazadeh-Rashti, G.

    2004-01-01

    Sodium Iodide-131 is administrated for treatment of hyperthyroidism and thyroid cancer. Iodine-131 has multiple routs of excretion (urine, saliva, sweat, milk, feces, exhalation) from the body. Patients receiving Sodium Iodide-131 therapy exposes other persons and the environment to unwanted radiation and contamination. The major sources of radiation dose from administration of Iodine-131 is external radiation , also there is a potential for exposure via contamination.Precautions are necessary to limit the radiation dose to family members, nursing staff and members of public and waste treatment workers to less than 1mSv. Patients received Sodium Iodide-131 may come into close contact with other persons. In order to derive appropriate recommendations, dose rates were measured from the anterior mid-trunk of 29 patients in the upright position with 15 minutes post-dose administration at 3 meters and just before they left the nuclear medicine department at 0.5, 1, and 3 meters. We have also measured urinary iodide excretion in 29 patients to estimate Sodium Iodide-131 urinary excretion pattern in iranian patients. Based on results, the maximum cumulative dose to nursing staff was on third day (leaving day) still less than recommended dose bye ICRP. The cumulative dose family members will be more but regarding the time and distance in close contact it will be also less than recommended dose by ICRP.Radiation dose rate was decreased significantly on third day. The urinary excretion patterns in all patients were similar. The urinary excretion rate-time curve in all patients showed multiple peaks due to retention and redistribution of Iodine-131 or enterohepatic cycle of radioiodinated thyroid hormones, which didn't allow calculation of urinary excretion rate constant. The results also showed that 67 hours post administration of Sodium Iodide-131 about 70% of radiopharmaceutical was excreted through urine, 28% physically decayed or eliminated through other biological

  1. Thyroid Adenomas After Solid Cancer in Childhood

    Energy Technology Data Exchange (ETDEWEB)

    Haddy, Nadia; El-Fayech, Chiraz; Guibout, Catherine; Adjadj, Elisabeth [Radiation Epidemiology Group, INSERM, Villejuif (France); Institut Gustave Roussy, Villejuif (France); Univ. Paris-Sud, Villejuif (France); Thomas-Teinturier, Cecile [Radiation Epidemiology Group, INSERM, Villejuif (France); Hopital Bicetre, Bicetre (France); Oberlin, Odile [Radiation Epidemiology Group, INSERM, Villejuif (France); Institut Gustave Roussy, Villejuif (France); Veres, Cristina [Radiation Epidemiology Group, INSERM, Villejuif (France); Institut Gustave Roussy, Villejuif (France); Univ. Paris-Sud, Villejuif (France); Pacquement, Helene [Institut Curie, Paris (France); Jackson, Angela [Radiation Epidemiology Group, INSERM, Villejuif (France); Institut Gustave Roussy, Villejuif (France); Univ. Paris-Sud, Villejuif (France); Munzer, Martine; N' Guyen, Tan Dat [Institut Jean Godinot, Reims (France); Bondiau, Pierre-Yves [Centre Antoine Lacassagne, Nice (France); Berchery, Delphine; Laprie, Anne [Centre Claudius Regaud, Toulouse (France); Bridier, Andre; Lefkopoulos, Dimitri [Institut Gustave Roussy, Villejuif (France); Schlumberger, Martin [Institut Gustave Roussy, Villejuif (France); Univ. Paris-Sud, Villejuif (France); Rubino, Carole; Diallo, Ibrahima [Radiation Epidemiology Group, INSERM, Villejuif (France); Institut Gustave Roussy, Villejuif (France); Univ. Paris-Sud, Villejuif (France); Vathaire, Florent de, E-mail: florent.devathaire@igr.fr [Radiation Epidemiology Group, INSERM, Villejuif (France); Institut Gustave Roussy, Villejuif (France); Univ. Paris-Sud, Villejuif (France)

    2012-10-01

    Purpose: Very few childhood cancer survivor studies have been devoted to thyroid adenomas. We assessed the role of chemotherapy and the radiation dose to the thyroid in the risk of thyroid adenoma after childhood cancer. Methods and Materials: A cohort of 3254 2-year survivors of a solid childhood cancer treated in 5 French centers before 1986 was established. The dose received by the isthmus and the 2 lobes of the thyroid gland during each course of radiation therapy was estimated after reconstruction of the actual radiation therapy conditions in which each child was treated as well as the dose received at other anatomical sites of interest. Results: After a median follow-up of 25 years, 71 patients had developed a thyroid adenoma. The risk strongly increased with the radiation dose to the thyroid up to a few Gray, plateaued, and declined for high doses. Chemotherapy slightly increased the risk when administered alone but also lowered the slope of the dose-response curve for the radiation dose to the thyroid. Overall, for doses up to a few Gray, the excess relative risk of thyroid adenoma per Gray was 2.8 (90% CI: 1.2-6.9), but it was 5.5 (90% CI: 1.9-25.9) in patients who had not received chemotherapy or who had received only 1 drug, and 1.1 (90% CI: 0.4-3.4) in the children who had received more than 1 drug (P=.06, for the difference). The excess relative risk per Gray was also higher for younger children at the time of radiation therapy than for their older counterparts and was higher before attaining 40 years of age than subsequently. Conclusions: The overall pattern of thyroid adenoma after radiation therapy for a childhood cancer appears to be similar to that observed for thyroid carcinoma.

  2. Thyroid Adenomas After Solid Cancer in Childhood

    International Nuclear Information System (INIS)

    Haddy, Nadia; El-Fayech, Chiraz; Guibout, Catherine; Adjadj, Elisabeth; Thomas-Teinturier, Cécile; Oberlin, Odile; Veres, Cristina; Pacquement, Hélène; Jackson, Angela; Munzer, Martine; N'Guyen, Tan Dat; Bondiau, Pierre-Yves; Berchery, Delphine; Laprie, Anne; Bridier, André; Lefkopoulos, Dimitri; Schlumberger, Martin; Rubino, Carole; Diallo, Ibrahima; Vathaire, Florent de

    2012-01-01

    Purpose: Very few childhood cancer survivor studies have been devoted to thyroid adenomas. We assessed the role of chemotherapy and the radiation dose to the thyroid in the risk of thyroid adenoma after childhood cancer. Methods and Materials: A cohort of 3254 2-year survivors of a solid childhood cancer treated in 5 French centers before 1986 was established. The dose received by the isthmus and the 2 lobes of the thyroid gland during each course of radiation therapy was estimated after reconstruction of the actual radiation therapy conditions in which each child was treated as well as the dose received at other anatomical sites of interest. Results: After a median follow-up of 25 years, 71 patients had developed a thyroid adenoma. The risk strongly increased with the radiation dose to the thyroid up to a few Gray, plateaued, and declined for high doses. Chemotherapy slightly increased the risk when administered alone but also lowered the slope of the dose-response curve for the radiation dose to the thyroid. Overall, for doses up to a few Gray, the excess relative risk of thyroid adenoma per Gray was 2.8 (90% CI: 1.2-6.9), but it was 5.5 (90% CI: 1.9-25.9) in patients who had not received chemotherapy or who had received only 1 drug, and 1.1 (90% CI: 0.4-3.4) in the children who had received more than 1 drug (P=.06, for the difference). The excess relative risk per Gray was also higher for younger children at the time of radiation therapy than for their older counterparts and was higher before attaining 40 years of age than subsequently. Conclusions: The overall pattern of thyroid adenoma after radiation therapy for a childhood cancer appears to be similar to that observed for thyroid carcinoma.

  3. Predictive value of pyramidal lobe, percentage thyroid uptake and age for ablation outcome after 15 mCi fixed dose of radioiodine-131 in Graves’ disease

    International Nuclear Information System (INIS)

    Zaman, Maseeh uz; Fatima, Nosheen; Zaman, Unaiza; Sajjad, Zafar; Zaman, Areeba; Tahseen, Rabia

    2015-01-01

    The purpose was to find out the efficacy of fixed 15 mCi radioactive iodine-131 (RAI) dose and predictive values of various factors for inducing hypothyroidism in Graves’ disease (GD). Retrospective study conducted from January 2012 till August 2014. Patients with GD who had a technetium-99m thyroid scan, thyroid antibodies, received fixed 15 mCi RAI and did follow endocrine clinics for at least 6 months were selected. RAI was considered successful if within 6 months of RAI therapy patients developed hypothyroidism. Of the 370 patients with GD who had RAI during study period, 210 (57%) qualified study criteria. Mean age of patients was 48 ± 15 years with female: male ratio of 69:31, positive thyroid antibodies in 61%, means thyroid uptake of 15.09 ± 11.23%, and presence of pyramidal lobe in 40% of total population. Hypothyroidism was achieved in 161 (77%) patients while 49 (23%) patients failed to achieve it (remained either hyperthyroid or euthyroid on antithyroid medication). Patients who became hypothyroid were significantly younger with higher proportion of presence of thyroid antibodies and pyramidal lobe and lower percentage thyroid uptake than those who failed. Multiple logistic regression analysis revealed that age (odds ratio; OR = 2.074), pyramidal lobe (OR = 3.317), thyroid antibodies (OR = 8.198), and percentage thyroid uptake (OR = 3.043) were found to be significant prognostic risk factors for post-RAI hypothyroidism. Gender was found to have nonsignificant association with the development of hypothyroidism. Receiver operating characteristic analysis revealed age <42 years and thyroid uptake <15% as threshold values for the development of post-RAI hypothyroidism. We conclude that fixed (15 mCi) RAI dose is highly effective in rendering hypothyroidism in patients with GD. Age (≤42 years), thyroid uptake (≤15%) and presence of pyramidal lobe are strong predictors of hypothyroidism and must be considered for selecting optimal RAI dose

  4. Study of the correlation between administered activity and radiation committed dose to the thyroid in 131I Therapy of Graves' Disease

    International Nuclear Information System (INIS)

    Traino, A.C.; Di Martino, F.; Lazzeri, M.; Stabin, M.G.

    2001-01-01

    Substantial reduction in the thyroid volume (up to 70-80%) after 131 I therapy of Graves' disease has been demonstrated and reported in the literature. Recently a mathematical model of thyroid mass reduction during the first month after therapy has been developed and a new algorithm for the radiation committed dose calculation has been proposed. Reduction of the thyroid mass and the radiation committed dose to the gland depend on a parameter k, defined for each subject. The calculation of k allows the prediction of the activity to administer, depending on the radiation committed dose chosen by the physician. In this paper a method for calculating k is proposed. The calculated values of k are compared to values derived from measurements of the changes in thyroid mass in twenty-six patients treated by 131 I for Graves' disease. The radiation committed dose to the thyroid can be predicted within 21%, and the radioiodine activity to administer to the patient can be predicted within 22% using the calculated values of k. The thyroid volume reduction during the first month after therapy administration can be also predicted with good accuracy using the calculated values of k. The radiation committed dose and the radioiodine activity to administer were calculated using a new, very simple algorithm. A comparison between the values calculated by this new algorithm and the old, classical Marinelli-Quimby algorithm shows that the new method is more accurate. (author)

  5. Dose assessment for brachytherapy with Henschke applicator

    International Nuclear Information System (INIS)

    Yu, Pei-Chieh; Chao, Tsi-Chian; Tung, Chuan-Jong; Wu, Ching-Jung; Lee, Chung-Chi

    2011-01-01

    Dose perturbation caused by the Henschke applicator is a major concern for the brachytherapy planning system (BPS) in recent years. To investigate dose impact owing to neglect of the metal shielding effect, Monte Carlo (MC) simulation, BPS calculation, and film measurement have been performed for dose assessment in a water phantom. Additionally, a cylindrical air cavity representing the rectum was added into the MC simulation to study its effect on dose distribution. Monte Carlo N-Particle Transport Code (MCNP) was used in this study to simulate the dose distribution using a mesh tally. This Monte Carlo simulation has been validated using the TG-43 data in a previous report. For the measurement, the Henschke applicator was placed in a specially-designed phantom, and Gafchromic films were inserted in the center plane for 2D dose assessment. Isodose distributions with and without the Henschke applicator by the MC simulation show significant deviation from those by the BPS. For MC simulation, the isodose curves shrank more significantly when the metal applicator was applied. For the impact of the added air cavity, the results indicate that it is hard to distinguish between with and without the cavity. Thus, the rectum cavity has little impact on the dose distribution around the Henschke applicator.

  6. Assessing Waste Water Treatment Plant Effluent for Thyroid Hormone Disruption

    Science.gov (United States)

    Much information has been coming to light on the estrogenic and androgenic activity of chemicals present in the waste water stream and in surface waters, but much less is known about the presence of chemicals with thyroid activity. To address this issue, we have utilized two assa...

  7. Estimated dose rates to members of the public from external exposure to patients with {sup 131}I thyroid treatment

    Energy Technology Data Exchange (ETDEWEB)

    Dewji, S., E-mail: dewjisa@ornl.gov; Bellamy, M.; Leggett, R.; Eckerman, K. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, Tennessee 37831 (United States); Hertel, N. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, Tennessee 37831 and Georgia Institute of Technology, 770 State Street, Atlanta, Georgia 30332-0745 (United States); Sherbini, S.; Saba, M. [United States Nuclear Regulatory Commission, Washington, DC 20555-0001 (United States)

    2015-04-15

    specific activities of {sup 131}I in the thyroid, bladder, and combined remaining tissues were calculated as a function of time after administration. Exposures to members of the public were considered for {sup 131}I patients with normal thyroid uptake (peak thyroid uptake of ∼27% of administered {sup 131}I), differentiated thyroid cancer (DTC, 5% uptake), and hyperthyroidism (80% uptake). Results: The scenario with the patient seated behind the member of the public yielded the highest dose rate estimate of seated public transportation exposure cases. The dose rate to the adjacent room guest was highest for the exposure scenario in which the hotel guest and patient are seated by a factor of ∼4 for the normal and differentiated thyroid cancer uptake cases and by a factor of ∼3 for the hyperthyroid case. Conclusions: It was determined that for all modeled cases, the DTC case yielded the lowest external dose rates, whereas the hyperthyroid case yielded the highest dose rates. In estimating external dose to members of the public from patients with {sup 131}I therapy, consideration must be given to (patient- and case-specific) administered {sup 131}I activities and duration of exposure for a more complete estimate. The method implemented here included a detailed calculation model, which provides a means to determine dose rate estimates for a range of scenarios. The method was demonstrated for variations of three scenarios, showing how dose rates are expected to vary with uptake, voiding pattern, and patient location.

  8. Estimated dose rates to members of the public from external exposure to patients with 131I thyroid treatment

    International Nuclear Information System (INIS)

    Dewji, S.; Bellamy, M.; Leggett, R.; Eckerman, K.; Hertel, N.; Sherbini, S.; Saba, M.

    2015-01-01

    in the thyroid, bladder, and combined remaining tissues were calculated as a function of time after administration. Exposures to members of the public were considered for 131 I patients with normal thyroid uptake (peak thyroid uptake of ∼27% of administered 131 I), differentiated thyroid cancer (DTC, 5% uptake), and hyperthyroidism (80% uptake). Results: The scenario with the patient seated behind the member of the public yielded the highest dose rate estimate of seated public transportation exposure cases. The dose rate to the adjacent room guest was highest for the exposure scenario in which the hotel guest and patient are seated by a factor of ∼4 for the normal and differentiated thyroid cancer uptake cases and by a factor of ∼3 for the hyperthyroid case. Conclusions: It was determined that for all modeled cases, the DTC case yielded the lowest external dose rates, whereas the hyperthyroid case yielded the highest dose rates. In estimating external dose to members of the public from patients with 131 I therapy, consideration must be given to (patient- and case-specific) administered 131 I activities and duration of exposure for a more complete estimate. The method implemented here included a detailed calculation model, which provides a means to determine dose rate estimates for a range of scenarios. The method was demonstrated for variations of three scenarios, showing how dose rates are expected to vary with uptake, voiding pattern, and patient location

  9. Ultrasonographic assessment of the thyroid gland structure in inflammatory bowel disease patients.

    Science.gov (United States)

    Neubauer, Katarzyna; Woźniak-Stolarska, Barbara

    2012-01-01

    The etiopathogenesis of inflammatory bowel disease (IBD), encompassing Crohn's disease (CD) and ulcerative colitis (UC), is still not fully elucidated and seems to be multifactorial. It has been suggested that genetic, immunological and environmental factors participate in IBD development. IBD extraintestinal manifestations include rheumatic, metabolic, dermatologic, ophthalmologic, hepatobiliary, pancreatic, urologic, pulmonary, neurological, hematological and thromboembolic complications. Thyroid gland diseases have not been confirmed as extraintestinal manifestations of IBD. However, it is known that some thyroid diseases share an immunological background with IBD, and that dysfunction of the thyroid gland may induce gastrointestinal symptoms. Ultrasound examination is the gold standard for evaluation of thyroid gland morphology. This study was designed to assess the prevalence of abnormalities in the structure of the thyroid gland in IBD patients and to compare it to the control group. The study group consisted of 199 consecutive IBD patients (80 CD patients and 119 UC patients) hospitalized at the Department of Gastroenterology and Hepatology of Wroclaw Medical University (Poland). The control group consisted of 42 healthy volunteers and patients with functional gastrointestinal disorders. The most common finding in the ultrasound examination in IBD patients were tumors. Tumors, which were smaller than or equal to 10 mm were present in 11.5% of IBD patients; and tumors larger than 10 mm were present in 13.1%. These results show that small tumors (less than 10 mm in diameter) of the thyroid gland are more frequent among patients with CD and UC compared to the control group (p = 0.0001 and p = 0.001, respectively). Additionally, enlargement of the thyroid gland occurs more often in UC patients compared to the control group (p = 0.003). There was no difference in the frequency of thyroid abnormalities between UC and CD patients. In patients with inflammatory

  10. Local dose assessment for a contaminated wound

    International Nuclear Information System (INIS)

    Piechowski, J.; Chaptinel, Y.

    2004-01-01

    Contaminated wounds present a great variability concerning the type of lesion. Assessment of the local dose is one amongst other factors for a decision as to the surgical operation. A simple model has been used to calculate the doses in a representative volume, that of a phalanx for instance. The dose rates are given for current radionuclides. The method of calculation is enough simple in order to allow the practitioners to use it in situations involving other radionuclides. Committed dose depends on the biological half-life which can be estimated from the local measurements. Some examples of calculation of committed dose are given considering half-lives characteristic of the compound. Transposition of the dose to the local risk is easy for the non-stochastic risk. Conversely, this is not the case for the risk of chronic inflammation or cancer. The latter question could only be solved by a feedback based on the analysis of real till now observed cases, nevertheless taking into account the fact that the available data are generally not so easy to make use for establishing an unquestionable dose - effect relation. A critical issue remains open as to the use of these doses for their comparison to the regulatory limits and for the subsequent decisions in case of exceeding the limits. The actual impact of an irradiation, especially by alpha particles, is not linked to the calculated dose in a simple and direct way. This question needs further consideration and perhaps a practical guide concerning this topic would be useful. The anatomical (surgical side effects), psychological and professional consequences should have a large weight relatively to the doses, obviously except for the cases, involving actually large contamination. (authors)

  11. Internal dose assessment in radiation accidents

    International Nuclear Information System (INIS)

    Toohey, R.E.

    2003-01-01

    Although numerous models have been developed for occupational and medical internal dosimetry, they may not be applicable to an accident situation. Published dose coefficients relate effective dose to intake, but if acute deterministic effects are possible, effective dose is not a useful parameter. Consequently, dose rates to the organs of interest need to be computed from first principles. Standard bioassay methods may be used to assess body contents, but, again, the standard models for bioassay interpretation may not be applicable because of the circumstances of the accident and the prompt initiation of decorporation therapy. Examples of modifications to the standard methodologies include adjustment of biological half-times under therapy, such as in the Goiania accident, and the same effect, complicated by continued input from contaminated wounds, in the Hanford 241 Am accident. (author)

  12. The embryogenesis of dose assessment at Hanford

    International Nuclear Information System (INIS)

    Foster, R.F.

    1990-01-01

    Several significant events occurred between 1955 and 1960 that resulted in major changes in environmental monitoring at Hanford and in the initiation of comprehensive dose assessments. These included: (1) specification of dose limits for nonoccupational exposure (including internal emitters); (2) a national and international awakening to the need for managing the disposal of radioactive wastes; (3) identification of the most important radionuclides and their sources of exposure; (4) data that quantified the transfer coefficients of nuclides along environmental pathways; and (5) development of greatly improved radiation detection instrumentation. In response to a growing need, the Hanford Laboratories formed the Environmental Studies and Evaluation component. This group revamped the monitoring and sampling programs so that analytical results contributed directly to dose estimation. Special studies were conducted to ascertain local dietary and recreational habits that affected dose calculations and to calibrate the models. These studies involved extensive contact with the public and governmental agencies, which elicited a positive reaction

  13. Inhalation dose assessment for Maralinga and Emu

    International Nuclear Information System (INIS)

    Johnston, P.N.; Lokan, K.H.; Williams, G.A.

    1990-01-01

    Dose assessments for the inhalation of artificial radionuclides are presented for all types of contaminated areas at Maralinga and Emu. These enable Committed Effective Dose Equivalent (CEDE), to be estimated by scaling at any area of interest where activity concentrations are known. In the case of Aborigines, these dose are estimated assuming respirable dust loadings of 1 mg/m 3 for adults and 1.5 mg/m 3 for children and infants. Details of the calculations are presented in the appendix. The model of the respiratory system used in this assessment is that described in Interantional Commission on Radiological Protection (ICRP) Publication 30 (ICRP, 1979a). With the exception of Kuli, which is contaminated with uranium, at all other sites it is only the inhalation of plutonium and americium that contributes significantly to the dose, and of these 239 Pu is the largest contributor. Therefore, considering the long half lives of the radionuclides concerned, it appears that the inhalation problems highlighted by this dose assessment will not diminish significantly within any reasonable period of time and hence management strategies must be developed to deal with such problems. 32 refs., 5 tabs., 1 fig

  14. Dose assessment for Greifswald and Cadarache

    International Nuclear Information System (INIS)

    Raskob, W.

    1996-07-01

    Probabilistic dose assessments for accidental atmospheric releases of tritium and activation products as well as releases under normal operation conditions were performed for the sites of Greifswald, Germany, and Cadarache, France. Additionally, aquatic releases were considered for both sites. No country specific rules were applied and the input parameters were adapted as far as possible to those used within former ITER studies to have a better comparison to site independent dose assessments performed in the frame of ITER. The main goal was to complete the generic data base with site specific values. The agreement between the results from the ITER study on atmospheric releases and the two sites are rather good for tritium, whereas the ITER reference dose values for the activation product releases are often lower, than the maximum doses for Greifswald and Cadarache. However, the percentile values fit better to the deterministic approach of ITER. Within all scenarios, the consequences of aquatic releases are in nearly all cases smaller than those from comparable releases to the atmosphere (HTO and steel). This rule is only broken once in case of accidental releases of activated steel from Cadarache. However, the uncertainties associated with the aquatic assessments are rather high and a better data base is needed to obtain more realistic and thus more reliable dose values. (orig.) [de

  15. The MESORAD dose assessment model: Computer code

    International Nuclear Information System (INIS)

    Ramsdell, J.V.; Athey, G.F.; Bander, T.J.; Scherpelz, R.I.

    1988-10-01

    MESORAD is a dose equivalent model for emergency response applications that is designed to be run on minicomputers. It has been developed by the Pacific Northwest Laboratory for use as part of the Intermediate Dose Assessment System in the US Nuclear Regulatory Commission Operations Center in Washington, DC, and the Emergency Management System in the US Department of Energy Unified Dose Assessment Center in Richland, Washington. This volume describes the MESORAD computer code and contains a listing of the code. The technical basis for MESORAD is described in the first volume of this report (Scherpelz et al. 1986). A third volume of the documentation planned. That volume will contain utility programs and input and output files that can be used to check the implementation of MESORAD. 18 figs., 4 tabs

  16. Assessment of external dose indoors in Lithuania

    International Nuclear Information System (INIS)

    Pilkyte, L.; Butkus, D.; Morkunas, G.

    2006-01-01

    The aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995-2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y -1 . The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials. (authors)

  17. Readability assessment of online thyroid surgery patient education materials.

    Science.gov (United States)

    Patel, Chirag R; Cherla, Deepa V; Sanghvi, Saurin; Baredes, Soly; Eloy, Jean Anderson

    2013-10-01

    Published guidelines recommend written health information be written at or below the sixth-grade level. We evaluate the readability of online materials related to thyroid surgery. Thyroid surgery materials were evaluated using Flesch Reading Ease Score (FRES), Flesch Kincaid Grade Level (FKGL), Gunning Frequency of Gobbledygook (GFOG), and Simple Measure of Gobbledygook (SMOG). Thirty-one documents were evaluated. FRES scores ranged from 29.3 to 67.8 (possible range = 0 to 100), and averaged 50.5. FKGL ranged from 6.9 to 14.9 (possible range = 3 to 12), and averaged 10.4. SMOG scores ranged from 11.8 to 14.5 (possible range = 3 to 19), and averaged 13.0. GFOG scores ranged from 10.6 to 18.0 (possible range = 3 to 19), and averaged 13.5. Readability scores for online thyroid surgery materials are higher (i.e., more difficult) than the recommended levels. However, readability is only one aspect of comprehension. Written information should be designed with that fact in mind. Copyright © 2013 Wiley Periodicals, Inc.

  18. Assessment of ovarian reserve in euthyroid adolescents with Hashimoto thyroiditis.

    Science.gov (United States)

    Pirgon, Ozgur; Sivrice, Cigdem; Demirtas, Hakan; Dundar, Bumin

    2016-01-01

    We aimed to investigate the ovarian function and reserve in euthyroid adolescents (TSH Hashimoto thyroiditis (HT). This case-control study included 30 adolescent girls (mean age 15.1 ± 1.4 years) newly diagnosed as HT with presence of high thyroid antibodies with gland heterogeneity in ultrasound and age-matched 30 healthy female subjects. Anti-ovarian antibody (AOAb), LH/FSH ratio, estradiol, anti-mullerian hormone (AMH), inhibin-B, total testosterone, antral follicle count, ovarian volumes and uterine length were measured. The clinical, laboratory, and ultrasound data of the HT and control groups were compared. There were no significant differences between the girls with HT and healthy controls in relation to LH/FSH ratio, estradiol and inhibin-B levels. AOAb (p = 0.02), AMH (p = 0.007) and total testosterone levels were higher in HT group than the control group (p = 0.03). AOAb level was found to be positively correlated with LH/FSH ratio (p = 0.03), AMH (p = 0.01) and inhibin-B (p thyroiditis had normal ovarian reserve based on measurements of AMH, inhibin B, FSH, LH/FSH ratio, estradiol and antral follicle counts.

  19. HiLo: Multicentre randomized phase III clinical trial of high vs low dose radioiodine, with or without recombinant human thyroid stimulating hormone (rhTSH), for remnant ablation for differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mallick, U. [Freeman Hospital, Newcastle, Newcastle upon Tyne (United Kingdom); Harmer, C.; Clarke, S.; Moss, L.; Nicol, A.; Clarke, P.; Smellie, J.; McCready, R.; Farnell, K.; Franklyn, J.; John, R.; Nutting, C.; Yap, B.; Lemon, C.; Wadlsey, J.; Gerrard, G.; Roques, T.; Macias, E.; Whitaker, S.; Abdul-Hamid, A.; Alvarez, P.; Kadalayil, L.; Hackshaw, A.

    2012-07-01

    Recommended treatment for most patients with differentiated thyroid cancer is surgery followed by radioiodine ablation. Current practice in many centres is to use a high administered activity of 3.7 GBq (100 mCi). However, a lower activity (1.1 GBq or 30 mCi) has advantages including a shorter stay in hospital isolation and lower risk of side effects, including the risk of a second cancer. Also, Thyrogen (rhTSH) allows patients to continue thyroid hormone replacement during ablation, avoiding symptoms of hypothyroidism and also reduces total body radiation dose. We conducted a large randomized factorial multi centre trial to simultaneously address whether ablation success rates are similar using (i) either 1.1 GBq or 3.7 GBq, and (ii) either Thyrogen or thyroid hormone withdrawal. It is the first ever national prospective trial in thyroid cancer in the UK. Final results will be available in 2011

  20. Human data and internal dose assessment

    International Nuclear Information System (INIS)

    Kawamura, H.; Tanaka, G.; Shiraishi, K.; Yamamoto, M.

    1992-01-01

    Recent data on physical and anatomical and physiological or metabolic data regarding Japanese Reference Man is briefly reviewed. This includes reference values for masses of all organs and tissues proposed for a Japanese Reference male adult. Part of the data is used to assess alpha doses to bone tissues from naturally occurring 226 Ra in bone of Japanese adult. (author)

  1. Dose absorbed in adults and children thyroid due to the I123 using the dosimetry MIRD and Marinelli

    International Nuclear Information System (INIS)

    Vasquez, M.; Castillo, C.; Cabrera, C.; Sarachaga, R.; Castaneda, J.; Diaz, E.

    2014-08-01

    Using the dosimetry MIRD, and representation Cristy-Eckerman in the thyroid gland and organs of their bio-kinetics when I 123 (Iodine) is used, the study demonstrates that the absorbed dose by the gland of an adult, children, and newly born, is their auto-dose, independent of the compartments number of their bio-kinetics. The dosimetric contributions of the organs of their bio-kinetics are insignificant. Their results are not significantly different to those obtained by the formalism MARINELLI (auto-dose) when it uses a sphere like glandular representation. In consequence, the kinetic model corresponding to the glandular representation decreases to a compartment, where the gland can also be represented like a sphere. (Author)

  2. Determination of environmental radioactivity for dose assessment

    International Nuclear Information System (INIS)

    Nakoaka, A.; Fukushima, M.; Takagi, S.

    1980-01-01

    A method was devised to determine detection limits for radioactivity in environmental samples. The method is based on the 5 mrem/yr whole-body dose objective established by the Japan Atomic Enerty Commission and is valid for assessing the internal dose from radionuclides in the environment around a nuclear facility. Eleven samples and 15 radionuclides were considered. Internal dose was assumed to be one-half of the total dose (5 mrem/yr) and was assessed using the critical pathway method. Needed detection limits (NDLs) were established to confirm the dose of 5 mrem/yr when there was more than one radionuclide per sample. The NDLs for γ-emitters were 10 -5 pCi/l. for air; 10 -3 pCi/l. for seawater; 10 -1 pCi/l. for drinking water; 10 0 pCi/kg for vegetables and fish; 10 0 pCi/l. for milk; and 10 1 pCi/kg for molluscs, crustaceans, seaweeds, soil and submarine sediments. The NDLs for β-emitters were 1-1/100 of those for γ-emitters. (author)

  3. Real time source term and dose assessment

    International Nuclear Information System (INIS)

    Breznik, B.; Kovac, A.; Mlakar, P.

    2001-01-01

    The Dose Projection Programme is a tool for decision making in case of nuclear emergency. The essential input data for quick emergency evaluation in the case of hypothetical pressurised water reactor accident are following: source term, core damage assessment, fission product radioactivity, release source term and critical exposure pathways for an early phase of the release. A reduced number of radio-nuclides and simplified calculations can be used in dose calculation algorithm. Simple expert system personal computer programme has been developed for the Krsko Nuclear Power Plant for dose projection within the radius of few kilometers from the pressurised water reactor in early phase of an accident. The input data are instantaneous data of core activity, core damage indicators, release fractions, reduction factor of the release pathways, spray operation, release timing, and dispersion coefficient. Main dose projection steps are: accurate in-core radioactivity determination using reactor power input; core damage and in-containment source term assessment based on quick indications of instrumentation or on activity analysis data; user defines release pathway for typical PWR accident scenarius; dose calculation is performed only for exposure pathway critical for decision about evacuation or sheltering in early phase of an accident.(author)

  4. Dose assessment in the Marshall Islands

    International Nuclear Information System (INIS)

    Robison, William L.

    1978-01-01

    Bikini Atoll and Enewetak Atoll in the Marshall Islands were the sites of major U.S. weapons testing from 1948 through 1958. Both the Bikini and Knewetak people have expressed a desire to return to their native Atolls. In 1968 clean-up and resettlement of Bikini was begun. In 1972-73 the initial survey of Enewetak Atoll was conducted and clean-up began in 1977. Surveys have been conducted at both Atolls to establish the concentrations of radionuclides in the biota and to determine the external exposure rates. Subsequent to the surveys dose assessments have been made to determine the potential dose to returning (100) populations at both Atolls. This talk will include discussions of the relative importance of the critical exposure pathways (i.e., external exposure, inhalation, marine, terrestrial and drinking water), the predominant radionuclides contributing to the predicted doses for each pathway, the doses predicted for alternate living patterns, comparison to Federal Guidelines, the comparison between Atolls, some of the social problems created by adherence to Federal Guidelines and the follow-up research identified and initiated to help refine the dose assessments and better predict the long term use of the Atolls (86). (author)

  5. GATE based Monte Carlo simulation of planar scintigraphy to estimate the nodular dose in radioiodine therapy for autonomous thyroid adenoma

    Energy Technology Data Exchange (ETDEWEB)

    Hammes, Jochen; Schmidt, Matthias; Schicha, Harald; Eschner, Wolfgang [Universitaetsklinikum Koeln (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Pietrzyk, Uwe [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Neurowissenschaften und Medizin (INM-4); Wuppertal Univ. (Germany). Fachbereich C - Physik

    2011-07-01

    The recommended target dose in radioiodine therapy of solitary hyperfunctioning thyroid nodules is 300-400 Gy and therefore higher than in other radiotherapies. This is due to the fact that an unknown, yet significant portion of the activity is stored in extranodular areas but is neglected in the calculatory dosimetry. We investigate the feasibility of determining the ratio of nodular and extranodular activity concentrations (uptakes) from post-therapeutically acquired planar scintigrams with Monte Carlo simulations in GATE. The geometry of a gamma camera with a high energy collimator was emulated in GATE (Version 5). A geometrical thyroid-neck phantom (GP) and the ICRP reference voxel phantoms 'Adult Female' (AF, 16 ml thyroid) and 'Adult Male' (AM, 19 ml thyroid) were used as source regions. Nodules of 1 ml and 3 ml volume were placed in the phantoms. For each phantom and each nodule 200 scintigraphic acquisitions were simulated. Uptake ratios of nodule and rest of thyroid ranging from 1 to 20 could be created by summation. Quantitative image analysis was performed by investigating the number of simulated counts in regions of interest (ROIs). ROIs were created by perpendicular projection of the phantom onto the camera plane to avoid a user dependant bias. The ratio of count densities in ROIs over the nodule and over the contralateral lobe, which should be least affected by nodular activity, was taken to be the best available measure for the uptake ratios. However, the predefined uptake ratios are underestimated by these count density ratios: For an uptake ratio of 20 the count ratios range from 4.5 (AF, 1 ml nodule) to 15.3 (AM, 3 ml nodule). Furthermore, the contralateral ROI is more strongly affected by nodular activity than expected: For an uptake ratio of 20 between nodule and rest of thyroid up to 29% of total counts in the ROI over the contralateral lobe are caused by decays in the nodule (AF 3 ml). In the case of the 1 ml nodules this

  6. GATE based Monte Carlo simulation of planar scintigraphy to estimate the nodular dose in radioiodine therapy for autonomous thyroid adenoma.

    Science.gov (United States)

    Hammes, Jochen; Pietrzyk, Uwe; Schmidt, Matthias; Schicha, Harald; Eschner, Wolfgang

    2011-12-01

    The recommended target dose in radioiodine therapy of solitary hyperfunctioning thyroid nodules is 300-400Gy and therefore higher than in other radiotherapies. This is due to the fact that an unknown, yet significant portion of the activity is stored in extranodular areas but is neglected in the calculatory dosimetry. We investigate the feasibility of determining the ratio of nodular and extranodular activity concentrations (uptakes) from post-therapeutically acquired planar scintigrams with Monte Carlo simulations in GATE. The geometry of a gamma camera with a high energy collimator was emulated in GATE (Version 5). A geometrical thyroid-neck phantom (GP) and the ICRP reference voxel phantoms "Adult Female" (AF, 16ml thyroid) and "Adult Male" (AM, 19ml thyroid) were used as source regions. Nodules of 1ml and 3ml volume were placed in the phantoms. For each phantom and each nodule 200 scintigraphic acquisitions were simulated. Uptake ratios of nodule and rest of thyroid ranging from 1 to 20 could be created by summation. Quantitative image analysis was performed by investigating the number of simulated counts in regions of interest (ROIs). ROIs were created by perpendicular projection of the phantom onto the camera plane to avoid a user dependant bias. The ratio of count densities in ROIs over the nodule and over the contralateral lobe, which should be least affected by nodular activity, was taken to be the best available measure for the uptake ratios. However, the predefined uptake ratios are underestimated by these count density ratios: For an uptake ratio of 20 the count ratios range from 4.5 (AF, 1ml nodule) to 15.3 (AM, 3ml nodule). Furthermore, the contralateral ROI is more strongly affected by nodular activity than expected: For an uptake ratio of 20 between nodule and rest of thyroid up to 29% of total counts in the ROI over the contralateral lobe are caused by decays in the nodule (AF 3 ml). In the case of the 1ml nodules this effect is smaller: 9-11% (AF

  7. GATE based Monte Carlo simulation of planar scintigraphy to estimate the nodular dose in radioiodine therapy for autonomous thyroid adenoma

    International Nuclear Information System (INIS)

    Hammes, Jochen; Schmidt, Matthias; Schicha, Harald; Eschner, Wolfgang; Pietrzyk, Uwe; Wuppertal Univ.

    2011-01-01

    The recommended target dose in radioiodine therapy of solitary hyperfunctioning thyroid nodules is 300-400 Gy and therefore higher than in other radiotherapies. This is due to the fact that an unknown, yet significant portion of the activity is stored in extranodular areas but is neglected in the calculatory dosimetry. We investigate the feasibility of determining the ratio of nodular and extranodular activity concentrations (uptakes) from post-therapeutically acquired planar scintigrams with Monte Carlo simulations in GATE. The geometry of a gamma camera with a high energy collimator was emulated in GATE (Version 5). A geometrical thyroid-neck phantom (GP) and the ICRP reference voxel phantoms 'Adult Female' (AF, 16 ml thyroid) and 'Adult Male' (AM, 19 ml thyroid) were used as source regions. Nodules of 1 ml and 3 ml volume were placed in the phantoms. For each phantom and each nodule 200 scintigraphic acquisitions were simulated. Uptake ratios of nodule and rest of thyroid ranging from 1 to 20 could be created by summation. Quantitative image analysis was performed by investigating the number of simulated counts in regions of interest (ROIs). ROIs were created by perpendicular projection of the phantom onto the camera plane to avoid a user dependant bias. The ratio of count densities in ROIs over the nodule and over the contralateral lobe, which should be least affected by nodular activity, was taken to be the best available measure for the uptake ratios. However, the predefined uptake ratios are underestimated by these count density ratios: For an uptake ratio of 20 the count ratios range from 4.5 (AF, 1 ml nodule) to 15.3 (AM, 3 ml nodule). Furthermore, the contralateral ROI is more strongly affected by nodular activity than expected: For an uptake ratio of 20 between nodule and rest of thyroid up to 29% of total counts in the ROI over the contralateral lobe are caused by decays in the nodule (AF 3 ml). In the case of the 1 ml nodules this effect is smaller: 9

  8. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Michael J; Joe, Alexius Y; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger [Department of Nuclear Medicine, University Hospital of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Brink, Ingo [Department of Nuclear Medicine, University Hospital of Freiburg (Germany); Krause, Thomas M [Department of Nuclear Medicine, Inselspital Bern (Switzerland)

    2002-09-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15{+-}9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256{+-}80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses. (orig.)

  9. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    International Nuclear Information System (INIS)

    Reinhardt, Michael J.; Joe, Alexius Y.; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger; Brink, Ingo; Krause, Thomas M.

    2002-01-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15±9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256±80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses. (orig.)

  10. Impaired DNA repair as assessed by the ``comet`` assay in patients developing thyroid carcinoma after radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Leprat, F.; Sarasin, A.; Suarez, H.G. [Institut de Recherches sur le Cancer, 94 - Villesuif (France); Leprat, F.; Alapetite, C.; Rosselli, F.; Ridet, A.; Moustacch, E.; Alapetite, C. [Institut Curie, 75 - Paris (France); Schlumberger, M. [Institut Gustave Roussy, 94 - Villejuif (France)

    1997-03-01

    A defective cellular response to DNA lesions induced be genotoxic agents may be associated to an increased cancer proneness. This has been clearly identified in some rare but extensively studied genetic diseases such as xeroderma pigmentosum (XP), ataxia telangiectasia (AT) and Fanconi anemia (FA). In practical oncology, most patients receive genotoxic therapeutic agents and the presence of so far unidentified sensitive genotypes could account for an increased susceptibility to cancer in a subgroup of exposed patients. The thyroid gland of children is especially sensitive to the carcinogenic effect of ionizing radiation. Evidence for risk is reported even at doses as low as 0.1 Gy, and the excess relative risk to develop a thyroid tumor following a radiation dose of 1 Gy in childhood is of 7.7 [l]. In order to determine if a defect in repair of DNA strand breaks could be involved, as an early step, in the development of secondary thyroid tumors after radiotherapy, we examined, using the alkaline single cell gel electrophoresis assay (SCGE or `comet`), the response to in vitro {gamma}-rays exposure of lymphocytes of a small group of patients who developed thyroid carcinoma after radiotherapy for a primary tumor. Because of its practical advantages, the alkaline comet assay offers the opportunity to question the role of DNA strand beaks rejoining capacity of the individual in the radiation induced carcinogenesis of thyroid tumors. This preliminary study of a small group of patients with therapeutic irradiation at childhood for a primary tumor indicates that, at the time of blood sampling, lymphocytes of some of these patients demonstrated reduced rejoining capacity. These results suggest that the comet assay might help to distinguish a subgroup of individuals at risk for radiation induced genomic instability and encourage further investigation. (authors)

  11. Influence of thyroid volume reduction on absorbed dose in "1"3"1I therapy studied by using Geant4 Monte Carlo simulation

    International Nuclear Information System (INIS)

    Rahman, Ziaur; Arshed, Waheed; Ahmed, Waheed; Mirza, Sikander M.; Mirza, Nasir M.

    2014-01-01

    A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of "1"3"1I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm"3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (± 6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for "1"3"1I radiotherapy of the thyroid. (authors)

  12. Evaluation of perturbations in serum thyroid hormones during human pregnancy due to dietary iodide and perchlorate exposure using a biologically based dose-response model.

    Science.gov (United States)

    Lumen, Annie; Mattie, David R; Fisher, Jeffrey W

    2013-06-01

    A biologically based dose-response model (BBDR) for the hypothalamic pituitary thyroid (HPT) axis was developed in the near-term pregnant mother and fetus. This model was calibrated to predict serum levels of iodide, total thyroxine (T4), free thyroxine (fT4), and total triiodothyronine (T3) in the mother and fetus for a range of dietary iodide intake. The model was extended to describe perchlorate, an environmental and food contaminant, that competes with the sodium iodide symporter protein for thyroidal uptake of iodide. Using this mode-of-action framework, simulations were performed to determine the daily ingestion rates of perchlorate that would be associated with hypothyroxinemia or onset of hypothyroidism for varying iodide intake. Model simulations suggested that a maternal iodide intake of 75 to 250 µg/day and an environmentally relevant exposure of perchlorate (~0.1 µg/kg/day) did not result in hypothyroxinemia or hypothyroidism. For a daily iodide-sufficient intake of 200 µg/day, the dose of perchlorate required to reduce maternal fT4 levels to a hypothyroxinemic state was estimated at 32.2 µg/kg/day. As iodide intake was lowered to 75 µg/day, the model simulated daily perchlorate dose required to cause hypothyroxinemia was reduced by eightfold. Similarly, the perchlorate intake rates associated with the onset of subclinical hypothyroidism ranged from 54.8 to 21.5 µg/kg/day for daily iodide intake of 250-75 µg/day. This BBDR-HPT axis model for pregnancy provides an example of a novel public health assessment tool that may be expanded to address other endocrine-active chemicals found in food and the environment.

  13. Bio-indicators for radiation dose assessment

    International Nuclear Information System (INIS)

    Trivedi, A.

    1990-12-01

    In nuclear facilities, such as Chalk River Laboratories, dose to the atomic radiation workers (ARWs) is assessed routinely by using physical dosimeters and bioassay procedures in accordance with regulatory recommendations. However, these procedures may be insufficient in some circumstances, e.g., in cases where the reading of the physical dosimeters is questioned, in cases of radiation accidents where the person(s) in question was not wearing a dosimeter, or in the event of a radiation emergency when an exposure above the dose limits is possible. The desirability of being able to assess radiation dose on the basis of radio-biological effects has prompted the Dosimetric Research Branch to investigate the suitability of biological devices and techniques that could be used for this purpose. Current biological dosimetry concepts suggest that there does not appear to be any bio-indicator that could reliably measure the very low doses that are routinely measured by the physical devices presently in use. Nonetheless, bio-indicators may be useful in providing valuable supplementary information in cases of unusual radiation exposures, such as when the estimated body doses are doubtful because of lack of proper physical measurements, or in cases where available results need to be confirmed for medical treatment plannings. This report evaluates the present state of biological dosimetry and, in particular, assesses the efficiency and limits of individual indicators. This has led to the recommendation of a few promising research areas that may result in the development of appropriate biological dosimeters for operational and emergency needs at Chalk River

  14. Marginal Iodide Deficiency and Thyroid Function: Dose-response analysis for quantitative pharmacokinetic modeling

    Science.gov (United States)

    Severe iodine deficiency is known to cause adverse health outcomes and remains a benchmark for understanding the effects of hypothyroidism. However, the implications of marginal iodine deficiency on function of the thyroid axis remain less well known. The current study examined t...

  15. Emergency preparedness in Finland: improvement of the measurement equipment used in the assessment of internal doses

    Energy Technology Data Exchange (ETDEWEB)

    Muikku, M.; Rahola, T. [STUK - Radiation and nuclear safety authority, Helsinki (Finland)

    2006-07-01

    The need for assessing internal radiation doses in emergency situations is evident. Internal exposure can be assessed using direct measurement results or by using information on activity concentrations in inhaled air and in foodstuffs combined with inhalation and consumption data. As a part of the continuous improving of emergency preparedness in Finland, S.T.U.K. - Radiation and Nuclear Safety Authority has obtained 35 monitors for thyroid measurements in field conditions and initiated a project to revise the radiation measurement equipment in local food and environmental laboratories. (authors)

  16. Thyroid equivalent dose in staffs that use neck lead protector in pediatric barium meal; Dose equivalente na tireoide dos profissionais que utilizam o protetor plumbifero nos exames de seed pediatrico

    Energy Technology Data Exchange (ETDEWEB)

    Filipov, Danielle; Sauzen, Jessica; Paschuk, Sergei A., E-mail: dfilipov@utfpr.edu.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Schelin, Hugo R.; Denyak, Valeriy [Instituto de Pesquisa Pele Pequeno Principe (IPPP), Curitiba, PR (Brazil); Legnani, Adriano [Hospital Pequeno Principe, Curitiba, PR (Brazil)

    2015-08-15

    The aim of this study is to estimate the thyroid equivalent dose in staffs that perform pediatric barium meal procedures and use neck lead protector. Thermoluminescent Dosimeters (TLDs) were positioned on the lead protectors, used by two professionals. After that, a solid state detector was exposed (with and without the protector above it). Therefore, it was possible to obtain both lead protectors attenuation factors. At the end, average and annual doses received by the TLDs and the thyroid (applying the attenuation factor over the dosimeters doses) were obtained. It was found that the average and annual equivalent doses in the thyroid gland are, respectively, higher than in comparative studies and within the established limits. With these data, it is concluded that the application of radiation protection optimization techniques is required. (author)

  17. Uncertainty on faecal analysis on dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Juliao, Ligia M.Q.C.; Melo, Dunstana R.; Sousa, Wanderson de O.; Santos, Maristela S.; Fernandes, Paulo Cesar P. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/n. Via 9, Recreio, CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2007-07-01

    Monitoring programmes for internal dose assessment may need to have a combination of bioassay techniques, e.g. urine and faecal analysis, especially in workplaces where compounds of different solubilities are handled and also in cases of accidental intakes. Faecal analysis may be an important data for assessment of committed effective dose due to exposure to insoluble compounds, since the activity excreted by urine may not be detectable, unless a very sensitive measurement system is available. This paper discusses the variability of the daily faecal excretion based on data from just one daily collection; collection during three consecutive days: samples analysed individually and samples analysed as a pool. The results suggest that just 1 d collection is not appropriate for dose assessment, since the 24 h uranium excretion may vary by a factor of 40. On the basis of this analysis, the recommendation should be faecal collection during three consecutive days, and samples analysed as a pool, it is more economic and faster. (authors)

  18. Dose. Detriment. Limit assessment; Dosis. Schadensmass. Grenzwertsetzung

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, J. [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz (IMPS)

    2015-07-01

    One goal of radiation protection is the limitation of stochastic effects due to radiation exposure. The probability of occurrence of a radiation induced stochastic effect, however, is only one of several other parameters which determine the radiation detriment. Though the ICRP-concept of detriment is a quantitative definition, the kind of detriment weighting includes somewhat subjective elements. In this sense, the detriment-concept of ICRP represents already at the stage of effective dose a kind of assessment. Thus, by comparing radiation protection standards and concepts interconvertible or with those of environment or occupational protection one should be aware of the possibly different principles of detriment assessment.

  19. Development on Dose Assessment Model of Northeast Asia Nuclear Accident Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Yub; Kim, Ju Youl; Kim, Suk Hoon; Lee, Seung Hee; Yoon, Tae Bin [FNC Techology, Yongin (Korea, Republic of)

    2016-05-15

    In order to support the emergency response system, the simulator for overseas nuclear accident is under development including source-term estimation, atmospheric dispersion modeling and dose assessment. The simulator is named NANAS (Northeast Asia Nuclear Accident Simulator). For the source-term estimation, design characteristics of each reactor type should be reflected into the model. Since there are a lot of reactor types in neighboring countries, the representative reactors of China, Japan and Taiwan have been selected and the source-term estimation models for each reactor have been developed, respectively. For the atmospheric dispersion modeling, Lagrangian particle model will be integrated into the simulator for the long range dispersion modeling in Northeast Asia region. In this study, the dose assessment model has been developed considering external and internal exposure. The dose assessment model has been developed as a part of the overseas nuclear accidents simulator which is named NANAS. It addresses external and internal pathways including cloudshine, groundshine and inhalation. Also, it uses the output of atmospheric dispersion model (i.e. the average concentrations of radionuclides in air and ground) and various coefficients (e.g. dose conversion factor and breathing rate) as an input. Effective dose and thyroid dose for each grid in the Korean Peninsula region are printed out as a format of map projection and chart. Verification and validation on the dose assessment model will be conducted in further study by benchmarking with the measured data of Fukushima Daiichi Nuclear Accident.

  20. Equivalent doses in thyroid tissue and residual body dose from radioiodine treatment of benign and malignant disorders of the thyroid as determined under therapeutic conditions. Bestimmung der Aequivalentdosen von Schilddruesengewebe und Restkoerper bei der Radiojodtherapie benigner und maligner Schilddruesenerkrankungen unter Therapiebedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Schad, K.

    1989-11-08

    The doses actually administered to patients undergoing radiotherapy for hyperthyroidism (104), autonomous adenoma (16) and goiter without functional anomaly (22) averaged 90, 165 and 100 Sv. Attempts were made to elucidate the causes of deviations between the predetermined dose and that actually administered, which occurred quite irrespective of whether a one-staged or split-dose regimen was used. Significant differences were occasionally also seen between the individual doses of fractionation regimens in respect of their uptake and effective half-life in the thyroidal tissue. It was calculated that the mean body dose remaining after each administration of radioactivity amounted to 0.6 mSv/MBq. In the majority of patients examined, clinical follow-up observations could be made for periods ranging from 6 to 41 months. Records were kept of all the results obtained. Further analyses were made to assess the mean residual body dose of carcinoma bearers subjected to wholebody radioiodine scintigraphy in the follow-up (14 patients) as well as of patients, in which secondary radioiodine treatment was carried out after thyroidectomy (59 patients). This was found to vary between 0.05 and 0.07 mSv/MBq. The significant discrepancies formerly determined for uptake rate and effective half-life between the individual sessions of one treatment course were confirmed by these examinations. (VHE).

  1. Thyroid dose of I-131 absorbed by the internal organs of a pregnant woman; Dosis tiroidea de I-131 absorbida por los organos internos de una embarazada

    Energy Technology Data Exchange (ETDEWEB)

    Arcos P, A; Manzanares A, E; Vega C, H R; Leon, C.L. de . [Cuerpo Academico de Radiobiologia de la Universidad Autonoma de Zacatecas (Mexico)

    2007-07-01

    The use of nuclear techniques, for diagnosis or treatment, generates stress in the patient and its relatives. During the pregnancy some sufferings related with the thyroid gland can be presented. If the patient is pregnant, OEP or NOEP, the stress comes from the fear to that the product can it turns affected. The dose is calculated that the Iodine 131, captured by the thyroid of a woman with three months of pregnancy, it deposits in the brain, stomach, heart, kidneys, liver, lungs, ovaries, pancreas, thymus, spleen and in the uterus. The thymus is the organ that receives the biggest dose. (Author)

  2. Dose assessment under incidental and accidental conditions

    International Nuclear Information System (INIS)

    Huebschmann, W.G.

    1988-01-01

    Dose assessment for the licesing process of a nuclear power plant covers the routine release of radioactive substances into the atmosphere as well as releases due to incidents. Source terms for these incidents are evaluated by the detailed incident analysis of the plant. The types of incidents to be covered are determined in the FRG by the ''Stoerfall-Leitlinien'' of the Ministry of the Interior. The calculation of dose equivalents in the environment of the plant differs from the calculation of doses due to routine releases, as incidents are single events occuring at undeterminate time, and the results must be conservative. Some details are being described. During the operation of the plant it is essential to measure not only the radioactivity release rates but also the necessary meteorological parameters for the instantaneous determination of the atmospheric dispersion in case of incidental or accidental releases of radioactivity. This instantaneous assessment assists in taking measurements of ground contamination and in deciding about countermeasures for the protection of plant personnell and population. (author) [pt

  3. [Thyroid nodule].

    Science.gov (United States)

    Clerc, Jérôme

    2005-01-31

    The thyroid nodule is a frequent, most often benign, chronic, multifocal and slowly progressive disease. The first line strategy is to diagnose cancerous nodules (thyroid nodules is controversial since the prognosis of thyroid cancer is excellent for lesions measuring less than 20 mm. Though imaging accuracy is quite limited in assessing the diagnosis of thyroid cancer, both ultrasounds (US) and thyroid scan are helpful to enhance nodular identification (>30%), to sort the nodules relevant for cytological sampling and to optimize the follow-up, the major source of health costs. Suspicious and non contributive FNAs must have a control FNA within 6 months. Nodules with a non suspicious FNA (>85%) require long term follow-up. This follow-up is mainly morphological. New or evolutive nodules, as assessed by palpation or US, will require iterative FNAs or should be considered for surgery. In patients with hyperfunctioning nodules on the scan (10 to 20%), a yearly evaluation of the TSH level is sufficient. These nodules account either for autonomously functioning ones, which slowly develop towards thyrotoxicosis, or for hyperplastic nodules frequently disclosing a lymphocytic thyroiditis. Morbidity due to thyroid autonomy is still underestimated especially in aging patients with TSH levels thyroid nodule is suggested.

  4. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  5. Combination TLD/TED dose assessment

    International Nuclear Information System (INIS)

    Parkhurst, M.A.

    1992-11-01

    During the early 1980s, an appraisal of dosimetry programs at US Department of Energy (DOE) facilities identified a significant weakness in dose assessment in fast neutron environments. Basing neutron dose equivalent on thermoluminescence dosimeters (TLDS) was not entirely satisfactory for environments that had not been well characterized. In most operational situations, the dosimeters overrespond to neutrons, and this overresponse could be further exaggerated with changes in the neutron quality factor (Q). Because TLDs are energy dependent with an excellent response to thermal and low-energy neutrons but a weak response to fast neutrons, calibrating the dosimetry system to account for mixed and moderated neutron energy fields is a difficult and seldom satisfactory exercise. To increase the detection of fast neutrons and help improve the accuracy of dose equivalent determinations, a combination dosimeter was developed using TLDs to detect thermal and low-energy neutrons and a track-etch detector (TED) to detect fast neutrons. By combining the albedo energy response function of the TLDs with the track detector elements, the dosimeter can nearly match the fluence-to-dose equivalent conversion curve. The polymer CR-39 has neutron detection characteristics superior to other materials tested. The CR-39 track detector is beta and gamma insensitive and does not require backscatter (albedo) from the body to detect the exposure. As part of DOE's Personnel Neutron and Upgrade Program, we have been developing a R-39 track detector over the past decade to address detection and measurement of fast neutrons. Using CR-39 TEDs in combination with TLDs will now allow us to detect the wide spectrum of occupational neutron energies and assign dose equivalents much more confidently

  6. Dosimetric evaluation in organs of the Tc99m, I123 bio-kinetics to estimate dose in thyroid children 1 and 5 years

    International Nuclear Information System (INIS)

    Vasquez, A. M.; Quispe, R.; Vasquez, D. J.; Rocha, M. D.; Morales, N. R.; Marin, R. K.; Zelada, A. L.

    2012-10-01

    Using the formalism MIRD and the representation of Cristy-Eckerman for the thyroid in children of 1 and 5 years, is demonstrated that the dosimetric contribution of the organs of I 123 (iodure) bio-kinetics is not significant in the dose estimate. The total dose absorbed by the gland is its auto dose. The dosimetric contribution of the organs source of the Tc 99m (pertechnetate) bio-kinetics in the gland is significant in the dose estimate like to be ignored. The reported results for the iodure are not significantly different to the found for the Marinelli scheme (auto-dose) for thyroid represented by a sphere of 1,78 and 3,45 grams. (Author)

  7. Evaluation of the dose received in the tissues of the neck during quantification of iodine in the thyroid by X-ray fluorescence spectrometry

    Science.gov (United States)

    Portararo, Antonio; Licour, Caroline; Gerardy, Isabelle; Pozuelo Navarro, Fausto

    2018-04-01

    The determination of the iodine content in the thyroid is of great interest for many investigations of this gland. The conventional scintigraphic method, using radionuclides, is efficient but delivers a significant dose to the patient. The X-ray fluorescence spectrometry could give information about the iodine content in the thyroid. The measured signal is obtained after stimulation of the stable iodine contained in the gland by X-rays. The advantage of this technique is the complete absence of radioactive isotope injected into the patient body. By applying this, a decrease in effective dose to the patient should be obtained. In this work, the study of the dose received by a thyroid phantom (surrounded by the different tissues of the neck) was performed. The phantom is made of PLA. The dose is measured in optimised conditions defined for the analytical technique. A total head-neck phantom was also used in order to consider the absorbed dose in each different tissues and organs as spinal cord or eyes. Thermo-luminescence dosimeters were chosen for their small size, their sensitivity and the easy positioning on the surface of the phantom but also inside of it to evaluate dose to internal organs. Those LiF 100 dosimeters have been calibrated within the X-ray beam also used for the analysis of iodine. The repeatability and reproducibility of the method has been evaluated. The influence of parameters as concentration of iodine in the thyroid, distance between the X-ray generator and the neck, thickness of the tissues surrounding the thyroid, has been investigated in terms of modifying parameters of the dose received by different tissues situated in the neck and the head.

  8. Dose in the uterus of a woman, with three months of pregnancy, due to the 131 I accumulated in her thyroid gland

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Arcos P, A.

    2006-01-01

    In this study the absorbed dose by the uterus of a woman with three months of pregnancy to who was applied a dose of 131 I that was accumulated in the thyroid gland is determined. The absorbed dose was obtained by means of Monte Carlo calculations developing a detailed three-dimensional model of the pregnant one, where they have been included most of the organs. The absorbed dose also was calculated by means of a simple procedure. To verify the calculated results it was carried out an experiment where was constructed a phantom of the neck, in this was included the thyroid with 131 I and the exposure was measured at different distances of the neck; this was related with the dose. Of the Monte Carlo calculation is obtained that for each mCi of 131 I that is retained in the mother's thyroid, the uterus absorbs a dose of 6.80 E(-11) Gy. When comparing the results, it was found that the simple calculation throws a result 29 times superior to that of the dose obtained by means of Monte Carlo. When applying a correction for the effect of the absorption of the gamma photons by the mother's body an absorbed dose in the uterus was obtained that is 0.16 times superior to the Monte Carlo calculation. Of the experimental phase it is verified that the values calculated by means of the simple method are equal to those experimentally measured. (Author)

  9. The Change of the Salivary Function after the High Dose Radioiodine Treatment in the patients with Differentiated Thyroid Cancer

    International Nuclear Information System (INIS)

    Lim, S. M.; Hong, S. W.; Lee, J. O.; Kang, T. W.

    1989-01-01

    The pain, swelling of salivary glands and dry mouth are not infrequent complication of the high dose radioiodine treatment in the patients with differentiated thyroid cancer. The purpose of this study was, by the dynamic salivary scintigraphy, to observe the change of the salivary function after the high dose (150-200 mCi) radioiodine treatment. From May 1987 to April 1988, the dynamic salivary scintigraphy with 5 mCi of 99m Tc-pertechnetate and gamma camera was performed before and 7 days after the radioiodine treatment in 7 patients with differentiated thyroid cancer. Just after the dynamic scintigraphy, the stimulation test with vitamin C solution of pH 3.0 and poststimulation scintigraphy were done, and the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were calculated for each gland. There was positive correlation between the radioactivity uptake index and excretion fraction after the stimulation. The salivary clearance after the stimulation was 18.96 ± 8.95 ml/min in the pretreatment state, and 14.37 ± 7.7 ml/min after the radioiodine treatment. After the radioiodine treatment, the radioactivity uptake index, excretion fraction and salivary clearance after the stimulation were significantly reduced in the parotid glands, but only the excretion fraction was reduced in the submandibular glands. The more the pretreatment salivary clearance after the stimulation was, the % change after the treatment was smaller. Further studies on the relation between the radiation dose in the salivary glands and the change of their function, and the long-term observation for the recovery of function are expected.

  10. Thyroid effects

    International Nuclear Information System (INIS)

    Maxon, H.; Thomas, S.; Buncher, C.; Book, S.; Hertzberg, V.

    1985-01-01

    Risk coefficients for thyroid disorders have been developed for both 131 I and external x or gamma low-LET radiation. A linear, no-threshold model has been used for thyroid neoplasms. A linear, threshold model has been used for other thyroid disorders. Improvements since the Reactor Safety Study were made possible by relevant new animal and human data. Major changes are as follows. Animal data are used to supplement the human experience where necessary. A specific risk estimate model is used for thyroid neoplasms, which accounts for observed effects of gender and age at exposure on risk. For thyroid cancer, the basis of the risk coefficients is the experience of North Americans following x-irradiation for benign disease in childhood. This recognizes possible differences in susceptibility in people of different heritage. A minimum induction period for thyroid neoplasms following irradiation is used to define periods at risk. An upper bound risk coefficient for cancer induction following exposure to 131 I is based on human experience at relatively low dose exposures. While the overall lifetime risks of death due to thyroid cancer are consistent with projections by the ICRP, BEIR III, and UNSCEAR Reports, the current model permits greater flexibility in determining risk for population subgroups. 88 references, 8 tables

  11. Assessment of dose during an SGTR

    International Nuclear Information System (INIS)

    Adams, J.P.

    1993-01-01

    The Nuclear Regulatory Commission requires utilities to determine the response of a pressurized water reactor to a steam generator tube rupture (SGTR) as part of the safety analysis for the plant. The SGTR analysis includes assumptions regarding the iodine concentration in the reactor coolant system (RCS) due to iodine spikes, primary flashing and bypass fractions, and iodine partitioning in the secondary coolant system (SCS). Experimental and analytical investigations have recently been completed wherein these assumptions were tested to determine whether and to what degree they were conservative (that is, whether they result in a calculated iodine source term/dose that is at least as large or larger than that expected during an actual event). The current study has the objective to assess the overall effects of the results of these investigations on the calculated iodine dose to the environment during an SGTR. To assist in this study, a computer program, DOSE, was written. This program uses a simple, non-mechanistic model to calculate the iodine source term to the environment during an SGTR as a function of water mass inventories and flow rates and iodine concentrations in the RCS and SCS. The principal conclusion of this study is that the iodine concentration in the RCS is the dominant parameter, due to the dominance of primary flashing on the iodine source term

  12. Thyroiditis: an integrated approach.

    Science.gov (United States)

    Sweeney, Lori B; Stewart, Christopher; Gaitonde, David Y

    2014-09-15

    Thyroiditis is a general term that encompasses several clinical disorders characterized by inflammation of the thyroid gland. The most common is Hashimoto thyroiditis; patients typically present with a nontender goiter, hypothyroidism, and an elevated thyroid peroxidase antibody level. Treatment with levothyroxine ameliorates the hypothyroidism and may reduce goiter size. Postpartum thyroiditis is transient or persistent thyroid dysfunction that occurs within one year of childbirth, miscarriage, or medical abortion. Release of preformed thyroid hormone into the bloodstream may result in hyperthyroidism. This may be followed by transient or permanent hypothyroidism as a result of depletion of thyroid hormone stores and destruction of thyroid hormone-producing cells. Patients should be monitored for changes in thyroid function. Beta blockers can treat symptoms in the initial hyperthyroid phase; in the subsequent hypothyroid phase, levothyroxine should be considered in women with a serum thyroid-stimulating hormone level greater than 10 mIU per L, or in women with a thyroid-stimulating hormone level of 4 to 10 mIU per L who are symptomatic or desire fertility. Subacute thyroiditis is a transient thyrotoxic state characterized by anterior neck pain, suppressed thyroid-stimulating hormone, and low radioactive iodine uptake on thyroid scanning. Many cases of subacute thyroiditis follow an upper respiratory viral illness, which is thought to trigger an inflammatory destruction of thyroid follicles. In most cases, the thyroid gland spontaneously resumes normal thyroid hormone production after several months. Treatment with high-dose acetylsalicylic acid or nonsteroidal anti-inflammatory drugs is directed toward relief of thyroid pain.

  13. Individualised dosimetry in patients with differentiated thyroid cancer based on external dose-rate. Optimisation of the number of measurements.

    Science.gov (United States)

    Bautista-Ballesteros, J A; Torres-Espallardo, I; Borrelli, P; Rivas-Sanchez, A; Bello, P; Martí-Bonmatí, L

    2016-01-01

    To compare the results of individual dosimetry in differentiated thyroid cancer patients treated with (131)I at our centre with the established limits and dosimetry results of published studies. Analysis of the optimal number of measurements necessary to reduce the impact of dosimetry for the comfort of the patient and, secondly, on the workload of health workers. Dosimetry was performed in the Nuclear Medicine Department of the University and Polytechnic Hospital La Fe, on 29 patients suffering from differentiated thyroid cancer and treated with activities between 1.02 and 5.51 GBq (mean 2.68 GBq) of (131)I. The Spanish Society of Medical Physics (SEFM) protocol was used, based on measurements of external dose rate adjusted to a bi-exponential curve according to a two compartment model. Different dosimetries were performed on each patient, taking different selections of the available measurements in order to find the optimal number. Results are well below the dosimetry limits, and are consistent with those obtained in other centres. The number of measurements can be reduced from 5, as proposed in the SEFM protocol, to 4 without significant loss of accuracy. Further reducing measures may be justified in individual cases. The values obtained for the dosimetry quantities are significantly below the established limits. A reduction in measurements can be assumed at the cost of a moderate increase in uncertainty, benefiting the patient. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  14. Classification of thyroid nodules using a resonance-frequency-based electrical impedance spectroscopy: progress assessment

    Science.gov (United States)

    Zheng, Bin; Tublin, Mitchell E.; Lederman, Dror; Klym, Amy H.; Brown, Erica D.; Gur, David

    2012-02-01

    The incidence of thyroid cancer is rising faster than other malignancies and has nearly doubled in the United States (U.S.) in the last 30 years. However, classifying between malignant and benign thyroid nodules is often difficult. Although ultrasound guided Fine Needle Aspiration Biopsy (FNAB) is considered an excellent tool for triaging patients, up to 25% of FNABs are inconclusive. As a result, definitive diagnosis requires an exploratory surgery and a large number of these are performed in the U.S. annually. It would be extremely beneficial to develop a non-invasive tool or procedure that could assist in assessing the likelihood of malignancy of otherwise indeterminate thyroid nodules, thereby reducing the number of exploratory thyroidectomies that are performed under general anesthesia. In this preliminary study we demonstrate a unique hand-held Resonance-frequency based Electrical Impedance Spectroscopy (REIS) device with six pairs of detection probes to detect and classify thyroid nodules using multi-channel EIS output signal sweeps. Under an Institutional Review Board (IRB)-approved case collection protocol, this REIS device is being tested in our clinical facility and we have been collecting an initial patient data set since March of this year. Between March and August of 2011, 65 EIS tests were conducted on 65 patients. Among these cases, six depicted pathology-verified malignant cells. Our initial assessment indicates the feasibility of easily applying this REIS device and measurement approach in a very busy clinical setting. The measured resonance frequency differences between malignant and benign nodules could potentially make it possible to accurately classify indeterminate thyroid nodules.

  15. Assessment of laboratory values of thyroid function tests in Sudanese patients

    International Nuclear Information System (INIS)

    Farah, Mansour El Tahir

    1997-01-01

    Thyroid diseases comprise a major health problem in Sudan. Although clinical diagnosis of thyroid diseases often easy, there are many diagnostic difficulties. So, laboratory investigations are essential in certain conditions. 97 Sudanese subjects were included in this study. According to the clinical features, patients were divided into three groups, either hyper or hypothyroid, and the control group. Laboratory diagnosis of these individuals was established in the diagnostic and research laboratory centre in Khartoum teaching hospital. The thyroid hormones studied are T 3 , T 4 , FT 4 (by enzyme immunoassay) and TSH (by the ultrasensitive enzyme immunoassay). Serum T 3 concentration was found to be high in 66% of the hyperthyroid patients, and low in 75% of the hypothyroid patients, and normal in 66.7% of the control group. Serum T 4 concentration was normal in one-third of the hyperthyroid patients, and one-fourth of the hypothyroid patients, and 90.9% of the control group. FT 4 was normal in the control group, low in 95% for the hypothyroid patients, and high in 66% of the hyperthyroid patients. Signs of hyperthyroidism were associated with high hormonal levels more than symptoms do. Hyperkinesis and eye signs had a significant correlation with the hormonal levels. No significant correlation was found between symptoms and signs of hypothyroidism and hormonal levels. So, clinical evaluation of patients is very important before assessing the laboratory values, and the free T 4 is more specific in the diagnosis of thyroid diseases. (Author)

  16. Dose assessment considering evolution of the biosphere

    International Nuclear Information System (INIS)

    Karlsson, Sara; Bergstroem, Ulla

    2002-01-01

    Swedish Nuclear Fuel and Waste Management AB (SKB) is presently updating the safety assessment for SFR (Final repository for radioactive operational waste) in Sweden. The bio-spheric part of the analysis is performed by Studsvik Eco and Safety AB. According to the regulations the safety of the repository has to be accounted for different possible courses of the development of the biosphere. A number of studies have been carried out during the past years to investigate and document the biosphere in the area surrounding the repository. Modelling of shore-level displacement by land uplift, coastal water exchange and sedimentation have provided data for prediction of the evolution of the area. The prediction is done without considering a future change in climatic conditions. The results from this study show that accumulation of radionuclides in sediments is an important process to simulate when performing dose assessments covering biosphere evolution. The dose calculated for the first years of the period with agricultural use of the contaminated sediments may be severely underestimated in a scenario with large accumulation in coastal and lake stages. (LN)

  17. Impact of intravenous contrast used in computed tomography on radiation dose to carotid arteries and thyroid in intensity-modulated radiation therapy planning for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Victor Ho Fun, E-mail: vhflee@hku.hk; Ng, Sherry Chor Yi; Kwong, Dora Lai Wan; Lam, Ka On; Leung, To Wai

    2017-07-01

    The aim of this study was to investigate if intravenous contrast injection affected the radiation doses to carotid arteries and thyroid during intensity-modulated radiation therapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC underwent plain computed tomography (CT) followed by repeated scanning after contrast injection. Carotid arteries (common, external, internal), thyroid, target volumes, and other organs-at-risk (OARs), as well as IMRT planning, were based on contrast-enhanced CT (CE-CT) images. All these structures and the IMRT plans were then copied and transferred to the non–contrast-enhanced CT (NCE-CT) images, and dose calculation without optimization was performed again. The radiation doses to the carotid arteries and the thyroid based on CE-CT and NCE-CT were then compared. Based on CE-CT, no statistical differences, despite minute numeric decreases, were noted in all dosimetric parameters (minimum, maximum, mean, median, D05, and D01) of the target volumes, the OARs, the carotid arteries, and the thyroid compared with NCE-CT. Our results suggested that compared with NCE-CT planning, CE-CT scanning should be performed during IMRT for better target and OAR delineation, without discernible change in radiation doses.

  18. Thyroid Diseases

    Science.gov (United States)

    ... beats. All of these activities are your body's metabolism. Thyroid problems include Goiter - enlargement of the thyroid gland Hyperthyroidism - when your thyroid gland makes more thyroid hormones ...

  19. Absorbed body dose simulation in Thyroid cancer therapy using MCNP4Cand ITScodes and comparison to experimental results

    International Nuclear Information System (INIS)

    Hadad, K.; Gorji, Y.

    2004-01-01

    Two standard particle transport codes of MCNP4C and integrated tiger series were used to estimate the total body dose in a thyroid cancer therapy study, with I-131 as the radionuclide source. Human body was modeled by water and soft tissue ellipsoids. Phantoms' dimensions were selected according to Brow nell recommendation. Absorbed fractions were calculated by both codes for different phantoms and for gammas with 0.364 MeV energy, which has the highest fraction in I-131 emitting gammas. Results were compared to the data published by Brow nell et.al.. Figure 1 shows the results of MCNP4C and Integrated Tiger Series with results published by Brow nell et. al.

  20. Dose evaluation in function of the thyroid captivation percentage and mass in patients under radiotherapy for toxic goiter treatment

    International Nuclear Information System (INIS)

    Alves, Aline Nunes; Antonio Filho, Joao

    2009-01-01

    Rarely the patient's metabolism is pondered when the quantity of radioactive material administrated to the patient is calculated. Nowadays, realizing till 150 mCi/g activities treatments are not indicated to toxic goiter radiotherapy. This paper objectives to establish a group of 13I -treatment options optimization for owner toxic goiter patients to maximize benefits and minimize radiological detriments. Methodology consisted of effective and absorbed whole-body and the other organs doses evaluations. And to observe the relation between these values and the thyroid mass and captivation percentage. The results, in spite of characteristic variations of each patient, showed such a homogeneity. This phenomenon happens because of explicit dependency on the real activity administrated to the patient. Used protocols for the toxic goiter treatment optimization avoiding waste of radioisotopes. (author)

  1. Increasing doses effect of L-T4 and L-T3 in the hypothalamus - hypophysis - thyroid in patients carrier of congenital and acquired hypothyroidism

    International Nuclear Information System (INIS)

    Cavaliere, H.

    1987-01-01

    The pituitary and peripheral response to L-T4 and L-T3 therapy were studied in 12 patients with congenital goitrous hypothyroidism, in 10 patients with an ectopic thyroid and onset of hypothyroidism at 3-8 years of age, and in 6 patients with adult-onset hypothyroidism, after they had had their chronic thyroid hormone replacement therapy discontinued for 30 days. They were first treated with increasing L-T4 (0.1, 0.2, and 0.4 mg daily) followed by L-T3 (0.05 and 0.2 mg daily) after stopping thyroid medication for another month. Ten normal subjects were treated identically. Since all patients received similar doses of thyroid hormones (μg/Kg of body weight) and had similar serum levels of T4 and T3 on each dose of L-T4 or L-T3, this paper concludes that congenitally hypothyroid patients have persistent pituitary resistance, but no peripheral resistance, to thyroid hormone. (author)

  2. Clinical Usefulness between High Dose Radioiodine Therapy and Helicobacter Pylori Infection after Total Thyroidectomy due to Well Differentiated Thyroid Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Kuk No; Lim, Seok Tae; Moon, Eun Ha; Kim, Jin Suk; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of)

    2009-12-15

    Helicobacter (H) pylori infection has been considered the most important cause of gastritis, dyspepsia, and gastroduodenal ulcer. Radioiodine can be accumulated in the remaining thyroid tissue, salivary gland, and stomach. We investigated if the high radiation induced by radioiodine in the stomach after high dose radioiodine therapy (HD-RIT) is effective in the eradication of H. pylori infection. One hundred ninety nine patients (M:F=33:166, age 46.7{+-}12.3 years) who had HD-RIT (dose 159.1{+-}25.9 mCi, range 120-250 mCi) after thyroidectomy due to well differentiated thyroid cancer were enrolled. To detect H. pylori infection, the urea breath tests (UBT) were performed at 1 hour before HD-RIT and at 4 weeks after HD-RIT. The results of UBT were classified as positive ({>=}50 dpm) or negative (<50 dpm), and analyzed its values. Of 199 patients, 103 (51.8%) patients had positive UBT before HD-RIT. Of these, 80 patients had follow-up UBT after HD-RIT. Among them, 76 (95.0%) patients had persistent positive UBT and only 4 (5.0%) patients were changed negative UBT. Among 76 patients with persistent positive UBT, 26 (34.2%) patients had increased the values of follow-up UBT, 49 (64.5%) had decreased them, and 1 (1.3%) had shown the same value. The different values of UBT between before and after HD-RIT were 62{+-}66.1 dpm in increased one of follow-up UBT, and 153.3{+-}157.1 dpm in decreased one of follow-up UBT. We conclude that the radiation induced by HD-RIT is ineffective in the eradication of H. pylori infection. However, it could be influential the degree or distribution of H. pylori infection.

  3. Clinical Usefulness between High Dose Radioiodine Therapy and Helicobacter Pylori Infection after Total Thyroidectomy due to Well Differentiated Thyroid Cancer

    International Nuclear Information System (INIS)

    Yun, Kuk No; Lim, Seok Tae; Moon, Eun Ha; Kim, Jin Suk; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee

    2009-01-01

    Helicobacter (H) pylori infection has been considered the most important cause of gastritis, dyspepsia, and gastroduodenal ulcer. Radioiodine can be accumulated in the remaining thyroid tissue, salivary gland, and stomach. We investigated if the high radiation induced by radioiodine in the stomach after high dose radioiodine therapy (HD-RIT) is effective in the eradication of H. pylori infection. One hundred ninety nine patients (M:F=33:166, age 46.7±12.3 years) who had HD-RIT (dose 159.1±25.9 mCi, range 120-250 mCi) after thyroidectomy due to well differentiated thyroid cancer were enrolled. To detect H. pylori infection, the urea breath tests (UBT) were performed at 1 hour before HD-RIT and at 4 weeks after HD-RIT. The results of UBT were classified as positive (≥50 dpm) or negative (<50 dpm), and analyzed its values. Of 199 patients, 103 (51.8%) patients had positive UBT before HD-RIT. Of these, 80 patients had follow-up UBT after HD-RIT. Among them, 76 (95.0%) patients had persistent positive UBT and only 4 (5.0%) patients were changed negative UBT. Among 76 patients with persistent positive UBT, 26 (34.2%) patients had increased the values of follow-up UBT, 49 (64.5%) had decreased them, and 1 (1.3%) had shown the same value. The different values of UBT between before and after HD-RIT were 62±66.1 dpm in increased one of follow-up UBT, and 153.3±157.1 dpm in decreased one of follow-up UBT. We conclude that the radiation induced by HD-RIT is ineffective in the eradication of H. pylori infection. However, it could be influential the degree or distribution of H. pylori infection

  4. Insulin resistance is associated with larger thyroid volume in adults with type 1 diabetes independently from presence of thyroid autoimmunity.

    Science.gov (United States)

    Rogowicz-Frontczak, Anita; Pilacinski, Stanislaw; Chwialkowska, Anna Teresa; Naskret, Dariusz; Zozulinska-Ziolkiewicz, Dorota

    2018-04-19

    To investigate the effect of insulin resistance (IR) on thyroid function, thyroid autoimmunity (AIT) and thyroid volume in type 1 diabetes (T1DM). 100 consecutive patients with T1DM aged 29 (±6) years with diabetes duration 13 (±6) years were included. Exclusion criteria were: history of thyroid disease, current treatment with L-thyroxin or anti-thyroid drugs. Evaluation of thyroid stimulating hormone (TSH), free thyroid hormones and anti-thyroid antibodies was performed. Thyroid volume was measured by ultrasonography. IR was assessed using the estimated glucose disposal rate (eGDR) formula. In the study group 22% of subjects had insulin resistance defined as eGDR lower or equal to 7.5 mg/kg/min. The prevalence of thyroid autoimmunity (positivity for ATPO or ATg or TRAb) in the study group was 37%. There were no significant differences in the concentration of TSH, FT3, FT4, the prevalence of AIT and hypothyroidism between IR and insulin sensitive (IS) group. Mean (±SD) thyroid volume was 15.6 (±6.2) mL in patients with IR and 11.7 (±4.7) mL in IS subjects (p = .002). Thyroid volume correlated inversely with eGDR (r = -0.35, p < .001). In a multivariate linear regression model the association between thyroid volume and eGDR was independent of sex, age, duration of diabetes, daily insulin dose, BMI, cigarette smoking, TSH value and presence of thyroid autoimmunity (beta: -0.29, p = .012). Insulin resisance is associated with larger thyroid volume in patients with type 1 diabetes independently of sex, body mass index, TSH value and presence of autoimmune thyroid disease.

  5. Outcomes of pregnancy in function of radiation dose to ovaries following a treatment with I131 for a differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Garsi, J.P.; Rubino, C.; Labbe, M.; Vathaire, F. de; Garsi, J.P.; Schlumberger, M.; Rubino, C.; Ricard, M.; Labbe, M.; Vathaire, F. de; Garsi, J.P.; Rubino, C.; Labbe, M.; Vathaire, F. de; Schvartz, C.; Henri-Amar, M.; Bardet, S.; Ceccarelli, C.

    2008-01-01

    Radiations are mutagen. During a treatment for a differentiated cancer of thyroid, the minimal activity of I 131 given to the patient is 3700 MBq producing a radiation dose to ovaries estimated to 140 mGy. In spite of the importance of this dose, few data on the outcomes of the pregnancy after irradiation are available. After our study it appears that the exposure to I 131 has no harmful effect on the outcomes of these pregnancies. (N.C.)

  6. Wound trauma alters ionizing radiation dose assessment

    Directory of Open Access Journals (Sweden)

    Kiang Juliann G

    2012-06-01

    Full Text Available Abstract Background Wounding following whole-body γ-irradiation (radiation combined injury, RCI increases mortality. Wounding-induced increases in radiation mortality are triggered by sustained activation of inducible nitric oxide synthase pathways, persistent alteration of cytokine homeostasis, and increased susceptibility to bacterial infection. Among these factors, cytokines along with other biomarkers have been adopted for biodosimetric evaluation and assessment of radiation dose and injury. Therefore, wounding could complicate biodosimetric assessments. Results In this report, such confounding effects were addressed. Mice were given 60Co γ-photon radiation followed by skin wounding. Wound trauma exacerbated radiation-induced mortality, body-weight loss, and wound healing. Analyses of DNA damage in bone-marrow cells and peripheral blood mononuclear cells (PBMCs, changes in hematology and cytokine profiles, and fundamental clinical signs were evaluated. Early biomarkers (1 d after RCI vs. irradiation alone included significant decreases in survivin expression in bone marrow cells, enhanced increases in γ-H2AX formation in Lin+ bone marrow cells, enhanced increases in IL-1β, IL-6, IL-8, and G-CSF concentrations in blood, and concomitant decreases in γ-H2AX formation in PBMCs and decreases in numbers of splenocytes, lymphocytes, and neutrophils. Intermediate biomarkers (7 – 10 d after RCI included continuously decreased γ-H2AX formation in PBMC and enhanced increases in IL-1β, IL-6, IL-8, and G-CSF concentrations in blood. The clinical signs evaluated after RCI were increased water consumption, decreased body weight, and decreased wound healing rate and survival rate. Late clinical signs (30 d after RCI included poor survival and wound healing. Conclusion Results suggest that confounding factors such as wounding alters ionizing radiation dose assessment and agents inhibiting these responses may prove therapeutic for radiation combined

  7. Accounting for shared and unshared dosimetric uncertainties in the dose response for ultrasound-detected thyroid nodules after exposure to radioactive fallout.

    Science.gov (United States)

    Land, Charles E; Kwon, Deukwoo; Hoffman, F Owen; Moroz, Brian; Drozdovitch, Vladimir; Bouville, André; Beck, Harold; Luckyanov, Nicholas; Weinstock, Robert M; Simon, Steven L

    2015-02-01

    Dosimetic uncertainties, particularly those that are shared among subgroups of a study population, can bias, distort or reduce the slope or significance of a dose response. Exposure estimates in studies of health risks from environmental radiation exposures are generally highly uncertain and thus, susceptible to these methodological limitations. An analysis was published in 2008 concerning radiation-related thyroid nodule prevalence in a study population of 2,994 villagers under the age of 21 years old between August 1949 and September 1962 and who lived downwind from the Semipalatinsk Nuclear Test Site in Kazakhstan. This dose-response analysis identified a statistically significant association between thyroid nodule prevalence and reconstructed doses of fallout-related internal and external radiation to the thyroid gland; however, the effects of dosimetric uncertainty were not evaluated since the doses were simple point "best estimates". In this work, we revised the 2008 study by a comprehensive treatment of dosimetric uncertainties. Our present analysis improves upon the previous study, specifically by accounting for shared and unshared uncertainties in dose estimation and risk analysis, and differs from the 2008 analysis in the following ways: 1. The study population size was reduced from 2,994 to 2,376 subjects, removing 618 persons with uncertain residence histories; 2. Simulation of multiple population dose sets (vectors) was performed using a two-dimensional Monte Carlo dose estimation method; and 3. A Bayesian model averaging approach was employed for evaluating the dose response, explicitly accounting for large and complex uncertainty in dose estimation. The results were compared against conventional regression techniques. The Bayesian approach utilizes 5,000 independent realizations of population dose vectors, each of which corresponds to a set of conditional individual median internal and external doses for the 2,376 subjects. These 5,000 population

  8. Preliminary dose assessment of the Chernobyl accident

    International Nuclear Information System (INIS)

    Hull, A.P.

    1987-01-01

    From the major accident at Unit 4 of the Chernobyl nuclear power station, a plume of airborne radioactive fission products was initially carried northwesterly toward Poland, thence toward Scandinavia and into Central Europe. Reports of the levels of radioactivity in a variety of media and of external radiation levels were collected in the Department of Energy's Emergency Operations Center and compiled into a data bank. Portions of these and other data which were obtained directly from published and official reports were utilized to make a preliminary assessment of the extent and magnitude of the external dose to individuals downwind from Chernobyl. Radioactive 131 I was the predominant fission product. The time of arrival of the plume and the maximum concentrations of 131 I in air, vegetation and milk and the maximum reported depositions and external radiation levels have been tabulated country by country. A large amount of the total activity in the release was apparently carried to a significant elevation. The data suggest that in areas where rainfall occurred, deposition levels were from ten to one-hundred times those observed in nearby ''dry'' locations. Sufficient spectral data were obtained to establish average release fractions and to establish a reference spectra of the other nuclides in the release. Preliminary calculations indicated that the collective dose equivalent to the population in Scandinavia and Central Europe during the first year after the Chernobyl accident would be about 8 x 10 6 person-rem. From the Soviet report, it appears that a first year population dose of about 2 x 10 7 person-rem (2 x 10 5 Sv) will be received by the population who were downwind of Chernobyl within the U.S.S.R. during the accident and its subsequent releases over the following week. 32 refs., 14 figs., 20 tabs

  9. Equivalent dose, effective dose and risk assessment from cephalometric radiography to critical organs

    International Nuclear Information System (INIS)

    Kang, Seong Sook; Cho, Bon Hae; Kim, Hyun Ja

    1995-01-01

    In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites (18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The following results were obtained; 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (3.6 μSv) and the next highest dose was that received by the bone marrow (3 μSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (2 μSv) and the next highest dose was that received by the bone marrow (1.8 μSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland (31.4 μSv) and the next highest dose was that received by the salivary gland (13.3 μSv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were 0.72 X 10 -6 , 0.49 X 10 -6 and 3.51 X 10 -6 , respectively.

  10. Population dose assessment: characteristics of PC CREAM

    International Nuclear Information System (INIS)

    Alonso, Maria T.; Curti, Adriana R.

    2000-01-01

    This paper presents the main features of the PC CREAM, a program for performing radiological impact assessments due to radioactive discharges into the environment during the operation of radioactive and nuclear facilities. PC CREAM is a suite of six programs that can be used to estimate individual and collective radiation doses. The methodology of PC CREAM is based on updated environmental and dosimetric models, including ICRP 60 recommendations. The models include several exposure pathways and the input files are easy to access. The ergonomics of the program improves the user interaction and makes easier the input of local data. This program is useful for performing sensitivity analysis, siting studies and validation of model comparing the activity concentration output data with environmental monitoring data. The methodology of each module is described as well as the output data. (author)

  11. A Study on 99mTc-pertechnetate thyroid uptake in various thyroid disease

    International Nuclear Information System (INIS)

    Choi, Sung Jae; Min, Hae Sook; Koh, Chang Soon; Lee, Mun Ho

    1974-01-01

    The 99m Tc-pertechnetate thyroid uptake rates(20 min) were measured in 24 healthy normal subjects, 140 patients with nontoxic goiter and 98 patients with thyrotoxicosis who were treated at the Thyroid Clinic, Seoul National University Hospital, from August 1972 to August 1973. Diagnostic reliabilities and correlations between 99m TcO 4 -thyroid uptake rate (20 min) and other thyroid function tests were evaluated. The observed results were as follows:1) The 99m TcO 4 - thyroid uptake rates (20 min) in normal subjects, euthyroid group and hyperthyroid group were 4.1±0.9%, 5.2±1.8% and 29.7±10.6%. There was a significant difference between the mean of the euthyroid group and the mean of the hyperthyroid group and so differentiation between them can be easy. 2) In the diagnosis of hyperthyroidism, the reliabilities of 99m TcO 4 - thyroid uptake rate(20 min), 131 I thyroid uptake rate (24 hrs), serum T 3 resin uptake rate, serum T 4 and T 7 were 87.9-97.9%, 81.2-94.4%, 87.9-97.9%, 90.5-99.3% and 93.7-100%. 99m TcO 4 -thyroid uptake rate (20 min) is more accurate than 131 I thyroid uptake rate (24 hrs) in the diagnosis of hyperthyroidism. 3) 99m TcO 4 -thyroid uptake rate (20 min) was well correlated with 131 I thyroid uptake rate (24 hrs), serum T 3 resin uptake rate, serum T 4 and T 7 . Points in favor of 99m Tc are that it gives a small radiation dose to the thyroid, that tests can be repeated at the short interval, the study can be completed at a single patient visit and it is particularly well suited for the assessment of thyroid function in patients being treated with an antithyroid drug.

  12. Determination of Therapeutic Dose of I-131 for First High Dose Radioiodine Therapy in Patients with Differentiated Thyroid Cancer: Comparison of Usefulness between Pathological Staging, Serum Thyroglobulin Level and Finding of I-123 Whole Body Scan

    International Nuclear Information System (INIS)

    Jeong, Hwan Jeong; Lim, Seok Tae; Youn, Hyun Jo; Sohn, Myung-Hee

    2008-01-01

    Recently, a number of patients needed total thyroidectomy and high dose radioiodine therapy (HD-RAI) get increased more. The aim of this study is to evaluate whether pathological staging (PS) and serum thyroglobulin (sTG) level could replace the diagnostic I-123 scan for the determination of therapeutic dose of HD-RAI in patients with differentiated thyroid cancer. Fifty eight patients (M:F=13;45, age 44.5±11.5 yrs) who underwent total thyroidectomy and central or regional lymph node dissection due to differentiated thyroid cancer were enrolled. Diagnostic scan of I-123 and sTG assay were also performed on off state of thyroid hormone. The therapeutic doses of I-131 (TD) were determined by the extent of uptakes on diagnostic I-123 scan as a gold standard. PS was graded by the criteria recommended in 6th edition of AJCC cancer staging manual except consideration of age. For comparison of the determination of therapeutic doses, PS and sTG were compared with the results of I-123 scan. All patients were underwent HD-RAI. Among them, five patients (8.6%) were treated with 100 mCi of I-131, forty three (74.1%) with 150 mCi, six (10.3%) with 180 mCi, three (5.2%) with 200 mCi, and one (1.7%) with 250 mCi, respectively. On the assessment of PS, average TDs were 154±25 mCi in stage I (n=9), 175±50 mCi in stage II (n=4), 149±21 mCi in stage III (n=38), and 161±20 mCi in stage IV (n=7). The statistical significance was not shown between PS and TD (p=0.169). Among fifty two patients who had available sTG, 25 patients (48.1%) having below 2 ng/mL of sTG were treated with 149±26 mCi of I-131, 9 patients (17.3%) having 2≤ sTG <5 ng/mL with 156±17 mCi, 5 patients (9.6%) having 5≤ sTG <10 ng/mL with 156±13 mCi, 7 patients (13.5%) having 10≤ sTG <50 ng/mL with 147±24 mCi, and 6 patients (11.5%) having above 50 ng/mL with 175±42 mCi. The statistical significance between sTG level and TD (p=0.252) was not shown. In conclusion, PS and sTG could not replace the

  13. A Technical Approach to Expedited Processing of NTPR Radiation Dose Assessments

    Science.gov (United States)

    2011-10-01

    all organs except thyroid, liver , gall bladder, and bile duct . These four organs are associated with low screening doses that are easily exceeded when... liver /gallbladder/ bile duct (25 occurrences) and thyroid (20 occurrences). This large number of occurrences is due, in part, to cancers of the liver ...to the gall bladder, bile duct , and acute lymphocytic leukemia do not satisfy the well-below criterion when the initial doses (neutron and gamma

  14. The interaction between lipid exchange and thyroid status in the conditions of prolonged influence of small doses of radiation

    Directory of Open Access Journals (Sweden)

    V. L. Sokolenko

    2017-05-01

    Full Text Available We studied the interaction between the indicators of lipid exchange and thyroid status among the inhabitants of radiation contaminated territories under additional psycho-emotional load. We observed 170 students aged between 18–24 and divided them into a control group of students who were from areas unaffected by radiation (70 people and the main experimental group of students from territories of increased radio-ecological load (IV radiation zone, 100 people. We determined the content of thyrotropic hormone (TTH, triiodothyronine (T3, thyroxin (T4, total cholesterin (TC, triglycerides (TG, cholesterin of lipoproteins of high density (Ch-LPHD and cholesterin of lipoproteins of low density (Ch-LPLD. We found that people who had lived since birth in territories which were contaminated with radionuclides and were affected by prolonged influence of small doses of ionizing radiation had significant fluctuations of indicators of concentrations of TTH, T3 and T4, forming manifestations of hypothyroidism and hyperthyrosis among some of those tested. Independently from hyperthyrosis, the effect was accompanied by growth in the level of TH, TG, Ch-LPHD and Ch-LPLD. Persons with manifestations of hypothyroidism had the content of TH above the upper limit of the homeostatic norm and the level of Ch-LPLD was higher than the norm in sub-groups with features of hypo- and hyperthyrosis. All those tested from the main group showed a significant positive correlation connection between the level of TTH and levels of TH and Ch-LPLD. The subgroup with manifestations of hyperthyrosis had a positive correlation between the levels of TTH and TG, the subgroups with manifestations of euthyroidism and hyperthyrosis had a negative correlation between the levels of TTH and Ch-LPHD. The hyperthyrosis subgroup had a significant positive correlation connection between T3 and TH and Ch-LPLD. The euthyroidism and hypothyroidism subgroups had a significant negative correlation

  15. Evaluation of the dose absorbed by the thyroid of patients undergoing treatment of Graves disease;Avaliacao da dose absorvida pela tireoide de pacientes submetidos ao tratamento da doenca de Graves

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Tiago L.; Filho, Joao A. [Universidade Catolica de Pernambuco (UNICAP), Recife, PE (Brazil). Dept. de Fisica; Silva, Jose M.F. da [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2009-07-01

    The radioiodine is used as complementary treatment of thyroid cancer and as first choice for the treatment of Graves' disease, being efficient, safe and easy administration, but without there is a protocol defined. This work was evaluated the thyroid absorbed dose from its mass and maximum uptake of I-131 obtained in the examination of diagnostic radiology of radiotherapeutic patients undergoing treatment of Graves' disease. Based on the results, it is observed that the thyroid absorbed dose, as much in terms of mass as the maximum uptake of I-131 for different values of administered activity, varies significantly. The analysis of these parameters is an excellent indicator for the pre-define quantity of radionuclide that is administered to the patient in terms of the radiation dose required to achieve an efficient therapeutic treatment. Moreover, it was observed that the thyroid absorbed dose depends on the degree of pathology of the disease, its mass and of the maximum uptake of I-131. (author)

  16. Dose selection for radioiodine therapy of borderline hyperthyroid patients with multifocal and disseminated autonomy on the basis of {sup 99m}Tc-pertechnetate thyroid uptake

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Michael J.; Mallek, Dirk von; Manka-Waluch, Agnieszka; Palmedo, Holger [Department of Nuclear Medicine, University Hospital Bonn (Germany); Joe, Alexius; Zimmerlin, Martina [Department of Nuclear Medicine, University Hospital Freiburg (Germany); Krause, Thomas M. [Department of Nuclear Medicine, Inselspital Bern (Switzerland)

    2002-04-01

    The aim of this study was to optimise radioiodine therapy of diffuse and nodular toxic goitre by calculation of the radiation dose delivered to the thyroid on the basis of the pretreatment technetium-99m pertechnetate thyroid uptake under thyrotropin suppression (TcTU{sub s}). The TcTU{sub s} value serves as a substitute for the non-suppressible iodine turnover and the functional autonomous mass. Marinelli's formula was used to calculate tissue absorbed doses of 150 Gy, 200 Gy, 250 Gy and 300 Gy to the thyroids of 438 patients with multifocal and disseminated autonomy. The mean age of patients was 70{+-}9 years, and the mean thyroid volume was 54{+-}26 ml. Two hundred and sixty-one of the patients had at least one documented previous episode of overt hyperthyroidism. Tissue absorbed doses were adapted to the pretreatment TcTU{sub s}: 150 Gy for a TcTU{sub s} of 1.5%-2.49%, 200 Gy for a TcTU{sub s} of 2.5%-3.49%, 250 Gy for a TcTU{sub s} of 3.5%-4.49% and 300 Gy for a TcTU{sub s} of {>=}4.5%. Normalisation of TcTU{sub s} and thyrotropin (TSH), thyroid volume reduction and frequency of hypothyroidism and recurrent hyperthyroidism were evaluated 1 year after a single radioiodine therapy. The presented dose strategy resulted in normalisation of TcTU{sub s} in 96% and an increase in TSH to the normal range in 92%. Recurrent hyperthyroidism was observed in only five patients. Thyroid volume decreased from 54{+-}26 before treatment to 34{+-}20 ml, a mean reduction of 37%. The frequency of hypothyroidism, at 0.9%, was encouragingly low. Dose selection in accordance with pretreatment TcTU{sub s} can be recommended for elimination of functional autonomous tissue with a single radioiodine therapy in patients of advanced age with enlarged thyroid glands and relevant autonomous masses who are at risk of developing iodine-induced hyperthyroidism. (orig.)

  17. Dose selection for radioiodine therapy of borderline hyperthyroid patients with multifocal and disseminated autonomy on the basis of 99mTc-pertechnetate thyroid uptake

    International Nuclear Information System (INIS)

    Reinhardt, Michael J.; Mallek, Dirk von; Manka-Waluch, Agnieszka; Palmedo, Holger; Joe, Alexius; Zimmerlin, Martina; Krause, Thomas M.

    2002-01-01

    The aim of this study was to optimise radioiodine therapy of diffuse and nodular toxic goitre by calculation of the radiation dose delivered to the thyroid on the basis of the pretreatment technetium-99m pertechnetate thyroid uptake under thyrotropin suppression (TcTU s ). The TcTU s value serves as a substitute for the non-suppressible iodine turnover and the functional autonomous mass. Marinelli's formula was used to calculate tissue absorbed doses of 150 Gy, 200 Gy, 250 Gy and 300 Gy to the thyroids of 438 patients with multifocal and disseminated autonomy. The mean age of patients was 70±9 years, and the mean thyroid volume was 54±26 ml. Two hundred and sixty-one of the patients had at least one documented previous episode of overt hyperthyroidism. Tissue absorbed doses were adapted to the pretreatment TcTU s : 150 Gy for a TcTU s of 1.5%-2.49%, 200 Gy for a TcTU s of 2.5%-3.49%, 250 Gy for a TcTU s of 3.5%-4.49% and 300 Gy for a TcTU s of ≥4.5%. Normalisation of TcTU s and thyrotropin (TSH), thyroid volume reduction and frequency of hypothyroidism and recurrent hyperthyroidism were evaluated 1 year after a single radioiodine therapy. The presented dose strategy resulted in normalisation of TcTU s in 96% and an increase in TSH to the normal range in 92%. Recurrent hyperthyroidism was observed in only five patients. Thyroid volume decreased from 54±26 before treatment to 34±20 ml, a mean reduction of 37%. The frequency of hypothyroidism, at 0.9%, was encouragingly low. Dose selection in accordance with pretreatment TcTU s can be recommended for elimination of functional autonomous tissue with a single radioiodine therapy in patients of advanced age with enlarged thyroid glands and relevant autonomous masses who are at risk of developing iodine-induced hyperthyroidism. (orig.)

  18. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... imaging tests to: determine if the gland is working properly help diagnose problems with the thyroid gland, such as an overactive thyroid gland, a condition called hyperthyroidism , cancer or other growths assess the ...

  19. Radioiodine therapy in Graves' disease based on tissue-absorbed dose calculations: effect of pre-treatment thyroid volume on clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Michael J.; Joe, Alexius Y.; Mallek, Dirk von; Ezziddin, Samer; Palmedo, Holger [Department of Nuclear Medicine, University Hospital of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Brink, Ingo [Department of Nuclear Medicine, University Hospital of Freiburg (Germany); Krause, Thomas M. [Department of Nuclear Medicine, Inselspital Bern (Switzerland)

    2002-09-01

    This study was performed with three aims. The first was to analyse the effectiveness of radioiodine therapy in Graves' disease patients with and without goitres under conditions of mild iodine deficiency using several tissue-absorbed doses. The second aim was to detect further parameters which might be predictive for treatment outcome. Finally, we wished to determine the deviation of the therapeutically achieved dose from that intended. Activities of 185-2,220 MBq radioiodine were calculated by means of Marinelli's formula to deliver doses of 150, 200 or 300 Gy to the thyroids of 224 patients with Graves' disease and goitres up to 130 ml in volume. Control of hyperthyroidism, change in thyroid volume and thyrotropin-receptor antibodies were evaluated 15{+-}9 months after treatment for each dose. The results were further evaluated with respect to pre-treatment parameters which might be predictive for therapy outcome. Thyroidal radioiodine uptake was measured every day during therapy to determine the therapeutically achieved target dose and its coefficient of variation. There was a significant dose dependency in therapeutic outcome: frequency of hypothyroidism increased from 27.4% after 150 Gy to 67.7% after 300 Gy, while the frequency of persistent hyperthyroidism decreased from 27.4% after 150 Gy to 8.1% after 300 Gy. Patients who became hypothyroid had a maximum thyroid volume of 42 ml and received a target dose of 256{+-}80 Gy. The coefficient of variation for the achieved target dose ranged between 27.7% for 150 Gy and 17.8% for 300 Gy. When analysing further factors which might influence therapeutic outcome, only pre-treatment thyroid volume showed a significant relationship to the result of treatment. It is concluded that a target dose of 250 Gy is essential to achieve hypothyroidism within 1 year after radioiodine therapy in Graves' disease patients with goitres up to 40 ml in volume. Patients with larger goitres might need higher doses

  20. Atherogenic index and coronarian risk – comparative assessment regarding the particularities of chronic autoimmune thyroiditis presence

    Directory of Open Access Journals (Sweden)

    Seceleanu Mihaela

    2015-08-01

    Full Text Available Objectives: Assessment of autoimmune cause hypothyroidism and dyslipidemia involvement in the apparition of major vascular complications. Methods: A total of 152 patients were investigated appreciating in comparison to a healthy control lot the hormone serum level, the presence of antimicrosomal thyroid antibodies and the serum levels of lipids. Atherogenic index and coronarian risk were calculated and correlated with the incidence of coronarian and cerebral vascular accidents. Results: Among the patients with goiter it was noted a high incidence of a subclinical hypothyroidism (31,58%. Thyroid autoimmunity was involved in 94,4% of the patients with clinical hypothyroidism, in 93,7 % with subclinical hypothyroidism and 100% in the patients with thyrotoxicosis. Low serum level of HDL-cholesterol was identified in 66,6% of patients with clinical hypothyroidism and 64,5% patients with subclinical hypothyroidism. The assessment of atherogenic index and coronarian risk was significantly higher (p<0,01 in patients with hypothyroidism in comparison to healthy control subjects. The incidence of vascular accidents was significantly higher (p<0,01 among the hypothyroid patients ( 19,7%/ 10,8%, of masculine gender (12,7% where the main cause of hypothyroidism was autoimmunity. Conclusions: The atherogenic index and coronarian risk were higher in patients with hypothyroidism associated to thyroid autoimmunity resulting in an increased probability in producing vascular accidents

  1. High efficiency mixed species radioiodine air sampling, readout, and dose assessment system

    International Nuclear Information System (INIS)

    Distenfeld, C.; Klemish, J.

    1976-05-01

    Reactor accidents require monitoring to assess the impact to persons in the environment. This implies methods and apparatus to accurately and economically sample and evaluate possible released activity. The development of a prototype iodine air sampling system that can differentiate against noble gas activity and be evaluated by standard Civil Defense instrumentation is reported. The apparatus can efficiently (95 percent) collect organic or inorganic, particulate or gaseous radioiodine in concentrations below stable atmospheric iodine, and under severe ambient conditions. Response to noble fission gases was reduced to less than 4 x 10 -4 of an equal iodine airborne activity by heating the collector to approximately 100 0 C. Reliable sample size, +-5 percent, was achieved by using a simple air flow regulator. Thyroid dose commitment was mathematically and graphically related to the iodine isotope distribution expected in the environment and to the response of the Civil Defense CDV-700 instrument used to evaluate the sample. Sensitivity of the method allows dose assessment of 1 to 2 rads to a child's thyroid

  2. Regulatory T cells and other lymphocyte subpopulations in patients with melanoma developing interferon-induced thyroiditis during high-dose interferon-α2b treatment.

    Science.gov (United States)

    Soldevila, Berta; Alonso, Núria; Martínez-Arconada, Maria J; Granada, Maria L; Boada, Aram; Vallejos, Virginia; Fraile, Manuel; Fernández-Sanmartín, Marco A; Pujol-Borrell, Ricardo; Puig-Domingo, Manel; Sanmartí, Anna; Martínez-Cáceres, Eva M

    2013-04-01

    One of the side effects of interferon-alpha therapy is interferon-induced thyroiditis (IIT). The role of lymphocyte subpopulations in IIT melanoma patients remains to be defined. Our objective was to assess different peripheral blood lymphocyte subpopulations, mainly regulatory T cells (Tregs), in melanoma patients who developed IIT. From 30 melanoma patients receiving high-dose interferon (HDI)-alpha 2b (IFN-α2b) treatment, those who developed IIT (IIT patients) were selected and compared with patients who did not develop IIT (Co-MM) and healthy controls (Co-H). Peripheral blood mononuclear cells were obtained before treatment (BT), mid-treatment (MT), end of treatment (ET), 24 weeks post-treatment and at appearance of IIT (TT). Nine patients developed IIT (30%): four Hashimoto's thyroiditis and five destructive thyroiditis. An increase in Tregs was observed in both melanoma groups during HDI treatment. A decrease in CD3(+) , NKT lymphocyte subpopulations and Bcl2 expression on B cells was also observed in both groups. However, no changes were observed in the percentage of CD4(+) , CD8(+) , CD3(+) γδ(+) , CD19(+) , transitional B cells (CD24(high) CD38(high) CD19(+) CD27(-) ), natural killer (NK), invariant NKT (iNKT) lymphocytes and Th1/Th2 balance when BT was compared with ET. At TT, IIT patients had a higher Tregs percentage than Co-MM (P = 0·012) and Co-H (P = 0·004), a higher iNKT percentage than Co-MM (P = 0·011), a higher transitional B cells percentage than Co-H (P = 0·015), a lower CD3(+) percentage than Co-H (P = 0·001) and a lower Bcl2 expression on B cells than Co-H (P < 0·001). Our results point to the immunomodulatory effects of IFN-α on different lymphocyte subpopulations and a possible role of Tregs in melanoma patients who developed IIT. © 2012 Blackwell Publishing Ltd.

  3. Evaluation of surface radiation dose to the thyroid gland and the gonads during routine full-mouth intraoral periapical and maxillary occlusal radiography

    Directory of Open Access Journals (Sweden)

    Soheyl Sheikh

    2010-01-01

    Full Text Available Aim: The quantitative aspects of radiation doses to critical organs can help the dental professionals to take the necessary radiation protective measures as deemed necessary and can help the general public to allay radiation exposure fear in dental radiography, if any. Our study determines the surface radiation dose to thyroid and gonads in full-mouth intraoral periapical (IOPA and maxillary occlusal radiography.Materials and Methods: A total number of 120 subjects participated in the study. The surface radiation dose was estimated to the thyroid gland and the gonads in full-mouth IOPA radiography using 10 IOPA (E speed films and in maxillary occlusal radiography. The measurements were calculated using a digital pocket dosimeter (PD-4507.Results: The average dose at the thyroid gland level during full-mouth intraoral and maxillary occlusal radiography was estimated to be 10.93 mRads (1.093 Χ 10 -2 mGy and 0.4 mRads (4.0 Χ 10 -2 mGy, respectively. The average surface radiation dose at the gonadal region during a full mouth intraoral and maxillary occlusal radiography was estimated to be 1.5 mRads (1.5 Χ 10 -2 mGy and 0.15 mRads (1.5 Χ 10 -3 mGy, respectively. Conclusion: Our results suggest that although the radiation exposure doses to critical organs namely thyroid and gonads is within the safe limits still precautionary measures for these organs are advocated.

  4. Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.

    Science.gov (United States)

    Esquinas, Pedro L; Tanguay, Jesse; Gonzalez, Marjorie; Vuckovic, Milan; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O; Celler, Anna

    2016-12-01

    In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the current is converted into units of activity by applying an appropriate calibration factor (also referred to as DC dial setting). Accurate determination of DC dial settings is crucial to ensure that patients receive the appropriate dose in diagnostic scans or radionuclide therapies. The goals of this study were (1) to describe a practical method to experimentally determine dose calibrator settings using a thyroid-probe (TP) and (2) to investigate the accuracy, reproducibility, and uncertainties of the method. As an illustration, the TP method was applied to determine 188 Re dial settings for two dose calibrator models: Atomlab 100plus and Capintec CRC-55tR. Using the TP to determine dose calibrator settings involved three measurements. First, the energy-dependent efficiency of the TP was determined from energy spectra measurements of two calibration sources ( 152 Eu and 22 Na). Second, the gamma emissions from the investigated isotope ( 188 Re) were measured using the TP and its activity was determined using γ-ray spectroscopy methods. Ambient background, scatter, and source-geometry corrections were applied during the efficiency and activity determination steps. Third, the TP-based 188 Re activity was used to determine the dose calibrator settings following the calibration curve method [B. E. Zimmerman et al., J. Nucl. Med. 40, 1508-1516 (1999)]. The interobserver reproducibility of TP measurements was determined by the coefficient of variation (COV) and uncertainties associated to each step of the measuring process were estimated. The accuracy of activity measurements using the proposed method was evaluated by comparing the TP activity estimates of 99m Tc

  5. Thyroid Dose Estimation Using WBC and I-131 Concentration in Working Area of Radioisotope Production at Normal Operation; Perkiraan Dosis Thyroid Melalui Pengukuran WBC dan Perhitungan dengan Konsentrasi I-131 Di Daerah Kerja Pada Operasi Normal Produksi Radioisotop

    Energy Technology Data Exchange (ETDEWEB)

    Tedjasari, R S; Lubis, E [Radioactive-Waste Management Technology Centre, National Atomic Energy Agency of Indonesia(Indonesia)

    1996-07-01

    Thyroid dose estimation at Radioisotope Production Centre workers using WBC and calculation based on I-131 concentration in working area has been done. The aim of this research is to get the relation between WBC result and calculation using I-131 concentration in working area. The result indicates differences in a range of 3,2% to 53,2%. These differences caused of parameters which influence the calculation are not accurate. These results also indicate that dose estimation using WBC is relatively batter and more accurate but need to have certain information about time of intake.

  6. Thyroid dysfunction after mantle irradiation of Hodgkin's disease patients

    International Nuclear Information System (INIS)

    Khoo, V.S.; Liew, K.H.; Crennan, E.C.; D'Costa, I.M.; Quong, G.

    1998-01-01

    Thyroid dysfunction can develop in patients with Hodgkin's disease who are treated with mantle irradiation. During the period 1970-89, the records of 320 patients who received mantle irradiation and who had thyroid function tests (TFT) were retrospectively reviewed. The median age was 30 years (range, 7-69 years). The median mantle and thyroid dose was 36 Gy (range, 30-40 Gy) and 39.8 Gy (range, 32-65 Gy), respectively. Overall thyroid dysfunction was present in 39% of the patients. Clinical hypothyroidism was seen in 10% and biochemical hypothyroidism was noted in 25%. Hyperthyroidism was found in 4% of patients. Thyroid nodules had developed in six patients (2%), of which those in four patients were malignant. Age, sex, histological subtype, stage of disease, dose, Iymphangiogram and treatment with chemotherapy were not significant factors in the development of thyroid dysfunction. The narrow dose range prevented adequate analysis of dose effect. The results indicate that the incidence of thyroid abnormalities is high enough to warrant regular TFT assessment with pre-irradiation levels and follow-up testing for life because the development of abnormalities can occur many years later. Thyroid examination should form part of the routine follow-up examination and any abnormality should be promptly investigated. Copyright (1998) Blackwell Science Pty Ltd

  7. A radiological dose assessment for the Port Hope conversion facility

    International Nuclear Information System (INIS)

    Garisto, N.C.; Cooper, F.; Janes, A.; Stager, R.; Peters, R.

    2011-01-01

    The Port Hope Conversion Facility (PHCF) receives uranium trioxide for conversion to uranium hexafluoride (UF 6 ) or uranium dioxide (UO 2 ). The PHCF Site has a long history of industrial use. A Radiological Dose Assessment was undertaken as part of a Site Wide Risk Assessment. This assessment took into account all possible human receptors, both workers and members of the public. This paper focuses on a radiological assessment of dose to members of the public. The doses to members of the public from terrestrial pathways were added to the doses from aquatic pathways to obtain overall dose to receptors. The benchmark used in the assessment is 1 mSv/y. The estimated doses related to PHCF operations are much lower than the dose limit. (author)

  8. Retrospective assessment of internal doses for short-term visitors to Fukushima within one month after the nuclear power plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Naoki [Nagasaki Univ., Center for Frontier Life Sciences, Nagasaki, Nagasaki (Japan); Kumagai, Atsushi; Ohtsuru, Akira [Fukushima Medical University, Fukushima, Fukushima (Japan); Morita, Naoko; Miura, Miwa; Yoshida, Masahiro; Kudo, Takashi; Takamura, Noboru; Yamashita, Shunichi [Nagasaki Univ., Graduate School of Biomedical Sciences, Nagasaki, Nagasaki (Japan)

    2012-11-15

    Short-term visitors to Fukushima have been monitored for internal exposure by using the whole body counter of the Nagasaki University Medical School. The total number of subjects exceeds 900 at the end of July, 2012. The highest committed effective dose and thyroid equivalent dose in 173 people who stayed in Fukushima during March 11th to April 10th, 2011 were assessed around 1 mSv and 20 mSv, respectively. (author)

  9. Dose assessments in nuclear power plant siting

    International Nuclear Information System (INIS)

    1988-03-01

    This document is mainly intended to provide information on dose estimations and assessments for the purpose of nuclear power plant (NPP) siting. It is not aimed at giving radiation protection guidance, criteria or procedures to be applied during the process of NPP siting nor even to provide recommendations on this subject matter. The document may however be of help for implementing some of the Nuclear Safety Standards (NUSS) documents on siting. The document was prepared before April 26, 1986, when a severe accident at the Unit 4 of Chernobyl NPP in the USSR had occurred. It should be emphasized that this document does not bridge the gap which exists in the NUSS programme as far as radiation protection guidance for the specific case of siting of NPP is concerned. The Agency will continue to work on this subject with the aim to prepare a safety series document on radiation protection requirements for NPP siting. This document could serve as a working document for this purpose. Refs, figs and tabs

  10. Assessment of laboratory values of thyroid function tests in Sudanese patients

    Energy Technology Data Exchange (ETDEWEB)

    Farah, Mansour El Tahir [Faculty of Medicine, University of Khartoum, Khartoum (Sudan)

    1998-12-31

    Thyroid diseases comprise a major health problem in Sudan. Although clinical diagnosis of thyroid diseases often easy, there are many diagnostic difficulties. So, laboratory investigations are essential in certain conditions. 97 Sudanese subjects were included in this study. According to the clinical features, patients were divided into three groups, either hyper or hypothyroid, and the control group. Laboratory diagnosis of these individuals was established in the diagnostic and research laboratory centre in Khartoum teaching hospital. The thyroid hormones studied are T{sup 3}, T{sup 4}, FT{sup 4} (by enzyme immunoassay) and TSH (by the ultrasensitive enzyme immunoassay). Serum T{sup 3} concentration was found to be high in 66% of the hyperthyroid patients, and low in 75% of the hypothyroid patients, and normal in 66.7% of the control group. Serum T{sup 4} concentration was normal in one-third of the hyperthyroid patients, and one-fourth of the hypothyroid patients, and 90.9% of the control group. FT{sup 4} was normal in the control group, low in 95% for the hypothyroid patients, and high in 66% of the hyperthyroid patients. Signs of hyperthyroidism were associated with high hormonal levels more than symptoms do. Hyperkinesis and eye signs had a significant correlation with the hormonal levels. No significant correlation was found between symptoms and signs of hypothyroidism and hormonal levels. So, clinical evaluation of patients is very important before assessing the laboratory values, and the free T{sup 4} is more specific in the diagnosis of thyroid diseases. (Author) 97 refs. , 20 tabs. , 11 figs.

  11. Thyroid measurements of Iodine-125 workers

    International Nuclear Information System (INIS)

    Burns, P.A.; Peggie, J.R.

    1979-02-01

    The accumulation of 125 I in the thyroid presents real hazards to workers who use this radionuclide. Recent assessments of the maximum permissible thyroid burden for 125 I have tended to be lower than those previously adopted. Workers using 125 I may receive small doses to a film badge monitor from external radiation while accumulating significant doses to the thyroid from internal contamination. It is therefore necessary to perform some form of thyroid monitoring on such workers. In the past two years the Australian Radiation Laboratory has monitored 125 I workers from six different institutations in the Melbourne area to determine the activity of 125 I in their thyroids. Most of the levels monitored were less than one tenth of the most recently recommended thyroid burden of 400 nanocurie. The highest levels were measured in workers who actually perform iodinations. Workers who handle the iodinate generally had lower levels than those performing the iodinations. Only a very small number of the workers measured were below the detectable limit of the system indicating that even when low activities of 125 I are handled in relatively stable forms it is still possible to accumulate 125 I in the thyroid

  12. Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality

    International Nuclear Information System (INIS)

    Geleijns, J.; Veldkamp, W.J.H.; Salvado Artells, M.; Lopez Tortosa, M.; Calzado Cantera, A.

    2006-01-01

    This study aimed at assessment of efficacy of selective in-plane shielding in adults by quantitative evaluation of the achieved dose reduction and image quality. Commercially available accessories for in-plane shielding of the eye lens, thyroid and breast, and an anthropomorphic phantom were used for the evaluation of absorbed dose and image quality. Organ dose and total energy imparted were assessed by means of a Monte Carlo technique taking into account tube voltage, tube current, and scanner type. Image quality was quantified as noise in soft tissue. Application of the lens shield reduced dose to the lens by 27% and to the brain by 1%. The thyroid shield reduced thyroid dose by 26%; the breast shield reduced dose to the breasts by 30% and to the lungs by 15%. Total energy imparted (unshielded/shielded) was 88/86 mJ for computed tomography (CT) brain, 64/60 mJ for CT cervical spine, and 289/260 mJ for CT chest scanning. An increase in image noise could be observed in the ranges were bismuth shielding was applied. The observed reduction of organ dose and total energy imparted could be achieved more efficiently by a reduction of tube current. The application of in-plane selective shielding is therefore discouraged. (orig.)

  13. Assessment of a new p-Mosfet usable as a dose rate insensitive gamma dose sensor

    International Nuclear Information System (INIS)

    Vettese, F.; Donichak, C.; Bourgeault, P.

    1995-01-01

    Dosimetric response of unbiased MOS devices has been assessed at dose rates greater than 2000 cGy/h. Application have been made to a personal dosemeter / dose rate meter to measure the absorbed tissue dose received in the case of acute external irradiation. (D.L.)

  14. Silent Thyroiditis

    Science.gov (United States)

    Walker, Peter

    1984-01-01

    Silent or painless thyroiditis is a frequent cause of transient hyperthyroidism, which is characterized by recent onset of symptoms in a patient with a normal to modestly enlarged and firm thyroid gland. The hallmarks of the disease are the absence of thyroidal pain or tenderness and a markedly reduced radioiodine uptake. Histologically, the gland is characterized by an important lymphocytic infiltration, occasionally to the point of lymphoid follicle formation. However, other indices of an autoimmune cause are usually absent. The disease appears to have a predilection for the postpartum period. Relapses may occur with subsequent pregnancies. Otherwise, the course is usually benign and transient, requiring moderate doses of β-adrenergic blocking agents for symptomatic relief. No pathogenetic factors are known, but the disease may conceivably have an autoimmune basis, particularly in the postpartum patient. PMID:21278944

  15. Assessing The Effect Of Ionizing Radiation On Fetal Of Differentiated Thyroid Cancer Pregnant Patients Who Have Been Treated By 131I

    International Nuclear Information System (INIS)

    Nguyen Van Kinh; Truong Quang Xuan; Phan Si An; Phung Nhu Toan; Bui Vo Minh Hoang

    2008-01-01

    1. Background: We tried to evaluate the female fertility and genetic risk to the offspring from the exposure to high-dose 131 I by assessing the pregnancy outcomes and chromosome aberrations ratio in the peripheral blood and amniotic fluid of female patients with differentiated thyroid cancer who had received therapeutic high - doses of 131 I. 2. Materials and Methods: From 2005 to march 2007, a total of 888 women had been treated with 131 I. Of these patients; 477 (53.71%) were in the reproductive age group (18 - 45 years). Twenty - two women had pregnancies after high-dose 131 I. Age at presentation ranged from 23 to 47 years (mean, 30 ± 5.2 years). Histopathology was papillary thyroid cancer in 21 cases and follicular thyroid cancer in 1 case. 3. Results: Single high-dose therapy was given in 2 cases, 2 doses were given in 12 cases, 3 doses were given in 3 cases, four and five doses were given in 5 cases in which lung metastases had occurred. In 22 patients (100%), disease was successfully ablated before pregnancy. Ovarian absorbed radiation dose calculated by MIRD method ranged from 4.2 to 95.2 cGy (mean, 32.25 ± 28.40 cGy). The interval between 131 I therapy and pregnancy varied from 3 to 48 months (16.6 ± 12.56 months). Chromosome aberrations ratio in peripheral blood (mean ± sem): Dicentric 0.905 ± 0.22%, Ring 0.29 ± 0.10%, Fragment 1.8 ± 0.33%, Translocation 3.95 ± 1.07%, inversion 0.238 ± 0.24%, deletion 1.57 ± 1.04%. Chromosome aberrations ratio in amniotic fluid: 19 case normal karyotyping, 01 case abnormal karyotype 47, XXY (Klinefelter) and one case had 0.15% delete q arm of 1 chromosome. Twenty - one babies (12 females and 9 males) were born, 01 case congenital malformation (4.5%). Twenty-one babies were healthy with birth weight had 3.26 ± 0.26 kg, TSH: 3.63 ± 2.38 μUI/ml, and normal developmental milestones. TSH concentration in the stage of the gestation had been in control 3 ± 4,72 μUI/ml. 4. Conclusions: Female fertility is not

  16. Program for rapid dose assessment in criticality accident, RADAPAS

    International Nuclear Information System (INIS)

    Takahashi, Fumiaki

    2006-09-01

    In a criticality accident, a person near fissile material can receive extremely high dose which can cause acute health effect. For such a case, medical treatment should be carried out for the exposed person, according to severity of the exposure. Then, radiation dose should be rapidly assessed soon after an outbreak of an accident. Dose assessment based upon the quantity of induced 24 Na in human body through neutron exposure is expected as one of useful dosimetry techniques in a criticality accident. A dose assessment program, called RADAPAS (RApid Dose Assessment Program from Activated Sodium in Criticality Accidents), was therefore developed to assess rapidly radiation dose to exposed persons from activity of induced 24 Na. RADAPAS consists of two parts; one is a database part and the other is a part for execution of dose calculation. The database contains data compendiums of energy spectra and dose conversion coefficients from specific activity of 24 Na induced in human body, which had been derived in a previous analysis using Monte Carlo calculation code. Information for criticality configuration or characteristics of radiation in the accident field is to be interactively given with interface displays in the dose calculation. RADAPAS can rapidly derive radiation dose to the exposed person from the given information and measured 24 Na specific activity by using the conversion coefficient in database. This report describes data for dose conversions and dose calculation in RADAPAS and explains how to use the program. (author)

  17. Population dose assessment from radiodiagnosis in Portugal

    International Nuclear Information System (INIS)

    Serro, R.; Carreiro, J.V.; Galvao, J.P.; Reis, R.

    1992-01-01

    A survey of radiodiagnostic installations was carried out in Portugal covering 75 premises including public hospitals, local and regional public health centres. A total of 175 X ray tubes was surveyed using the new NEXT methodology covering data on premises, tube and operator, and projection. Average value of voltage, current-time product, HVL, ratio of beam area to film area and source to film distance for the eleven most frequent projections are reported as well as the skin entrance exposure and the doses to some organs. The weighted average dose values per projection and for the different organs allowed an estimate of the whole-body dose per caput. From the gonadal doses the genetic significant dose was also estimated

  18. Radiation dose assessment in nuclear medicine

    International Nuclear Information System (INIS)

    Stabin, M.G.

    2002-01-01

    In any application involving the use of ionizing radiation in humans, risks and benefits must be properly evaluated and balanced. Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. Recently, interest has grown in therapeutic agents for a number of applications in nuclear medicine, particularly in the treatment of hematologic and non-hematologic malignancies. This has heightened interest in the need for radiation dose calculations and challenged the scientific community to develop more patient-specific and relevant dose models. Consideration of radiation dose in such studies is central to efforts to maximize dose to tumor while sparing normal tissues. In many applications, a significant absorbed dose may be received by some radiosensitive organs, particularly the active marrow. This talk will review the methods and models used in internal dosimetry in nuclear medicine, and discuss some current trends and challenges in this field

  19. [Dose-Response Dependences for Frequency of RET/PTC Gene Rearrangements in Papillary Thyroid Carcinoma after Irradiation. Simple Pooling Analysis of Molecular Epidemiological Data].

    Science.gov (United States)

    Koterov, A N; Ushenkova, L N; Biryukov, A P

    2016-01-01

    On the basis of all possible publications on the theme included in the previously formed base of sources on molecular epidemiology of RET/PTC rearrangements in thyroid papillary carcinoma a pooled analysis ("simple pooling data") on determination of the dose-effect dependences for RET/PTC frequency in radiogenic carcinomas of various irradiated groups was performed. (They are groups subjected to radiotherapeutic exposure, residents near the Chernobyl nuclear power plant (CNPP) and victims of nuclear bombing). The tendency to Pearson linear correlation (r = 0.746; p = 0.148) between the frequency of RET/PTC and the estimated dose on thyroid in the regions affected by the CNPP accident was revealed. But this tendency was recognized to be random owing to abnormally low values of the indicator for the most contaminated Gomel region. The method tentatively called "case-control" showed reliable differences in thyroid dose values for carcinomas with RET/PTC and without those. The versatility of changes was found: the lack of RET/PTC for radiotherapeutic impacts was associated with higher doses, whereas in case of the CNPP accident and for nuclear bombing victims it was the opposite. Probably, in the first case the "cellular cleaning" phenomenon after exposure to very high doses took place. Search of direct Pearson correlations between average/median thyroid doses on groups and RET/PTC frequency in carcinomas of these groups showed a high reliability for the dose-effect dependences- at the continuous dose scale (for RET/PTC in total and RET/PTC1 respectively: r = 0.830; p = 0.002 and r = 0.906; p = 0.0003); while there was no significant correlation received for RET/PTC3. When using the weighting least square regression analysis (proceeding from the number of carcinomas in samples), the specified regularities remained. Attempts to influence the strength of correlation by exception ofthe data of all the samples connected with the accident on the CNPP did not significantly

  20. Dose assessment in pediatric computerized tomography

    International Nuclear Information System (INIS)

    Vilarinho, Luisa Maria Auredine Lima

    2004-01-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI w obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI w values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI w . (author)

  1. Measurements of dose distribution in thyroids, gonads, crystalline and other organs, for radio-diagnostics with computorized tomography

    International Nuclear Information System (INIS)

    Coelho, M.J.

    1983-01-01

    An evaluation of radiation doses in organs, from radiologic examinations by computorized tomography was done, comparing with theoretic data obtained by Monte Carlo method. The measurements were done with help of a 'Rando Alderson Phantom' exposed to irradiation coming from a 0450 AS and E Pfizer Tomographic. The cases under study were the head and abdomen examinations. The dose assessment was done by using mini TLD's of LiF. The calculated dose equivalents were obtained by using the Monte Carlo method applied to a mathematical antropomorphic phantom, simulating the same experimental arrangements. The results were compared with the experimental one. (E.G.) [pt

  2. Postpartum Thyroiditis

    Science.gov (United States)

    American Thyroid Association ® Postpartum Thyroiditis www.thyroid.org What is the thyroid gland? The thyroid gland is a butterfly-shaped endocrine gland that ... as they should. What are the symptoms of postpartum thyroiditis? Thyroiditis is a general term that refers ...

  3. Occupational dose assessment in interventional cardiology in Serbia

    International Nuclear Information System (INIS)

    Kaljevic, J.; Ciraj-Bjelac, O.; Stankovic, J.; Arandjic, D.; Bozovic, P.; Antic, V.

    2016-01-01

    The objective of this work is to assess the occupational dose in interventional cardiology in a large hospital in Belgrade, Serbia. A double-dosimetry method was applied for the estimation of whole-body dose, using thermoluminescent dosemeters, calibrated in terms of the personal dose equivalent H p (10). Besides the double-dosimetry method, eye dose was also estimated by means of measuring ambient dose equivalent, H*(10), and doses per procedure were reported. Doses were assessed for 13 physicians, 6 nurses and 10 radiographers, for 2 consequent years. The maximum annual effective dose assessed was 4.3, 2.1 and 1.3 mSv for physicians, nurses and radiographers, respectively. The maximum doses recorded by the dosemeter worn at the collar level (over the apron) were 16.8, 11.9 and 4.5 mSv, respectively. This value was used for the eye lens dose assessment. Estimated doses are in accordance with or higher than annual dose limits for the occupational exposure. (authors)

  4. Determination of absorbed dose in crystalline and thyroid gland with irradiation protocols applied in orthopantomography equipment for dental examination

    International Nuclear Information System (INIS)

    Munoz A, A. A.; Ramirez A, L. M.; Sosa A, M. A.; Azorin V, J. C.; Vallejo H, M. A.

    2016-10-01

    Ionizing radiations are very useful in the medical field for the diagnostic use of different pathologies. Currently there are different technologies for diagnostic imaging using conventional X-ray, computed tomography, mammography, angiography, dental panoramic X-ray, among others. However, it should be noted that exposure to radiation in this type of diagnostic tests has increased considerably in recent years, because radiological examinations are not always carried out according to the actual clinical needs of each patient, increasing the risk to develop cancer. In this paper, the absorbed dose in the lens and thyroid gland was measured with the help of TLD-100 dosimeters located in a PMMA phantom adapted for orthopantomography (dental panoramic X-ray) equipment in 5 hospitals; using the parameters pre-configured for normal adult for irradiation. A Harshaw 3500 equipment was used to read the dosimeters, obtaining a value of 1.324 ± Sd 0.01 mGy for crystalline and 1.044 ± Sd 0.03 mGy values which are intended to be validated under other conditions and protocols. (Author)

  5. Eye dose assessment and management: overview

    International Nuclear Information System (INIS)

    Rehani, M.M.

    2015-01-01

    Some publications have shown that Hp( 0.07 ) or even Hp( 10 ) can be used as good operational quantities for X-rays in view of difficulties with Hp( 3 ). With increasing awareness, there is tendency to use whatever dosimeter is available with correction factor to estimate eye lens dose. The best position for an eye lens dosimeter has been reported to be at the side of the head nearest to the radiation source, close to the eye. Recent studies have reported eye doses with cone beam CT (CBCT) both for patients and staff, and there are many papers reporting eye lens doses to staff in nuclear medicine. To minimise the dose to eyes, the user can take advantage of a feature of CBCT of projections acquired over an angular span of 1808 plus cone angle of the X-ray tube and with tube under scan arcs. (authors)

  6. Radioiodine (I-131) treatment for uncomplicated hyperthyroidism: An assessment of optimal dose and cost-effectiveness

    International Nuclear Information System (INIS)

    Paul, A.K.; Rahman, H.A.; Jahan, N.

    2002-01-01

    Aim: Radioiodine (I-131) is increasingly being considered for the treatment of hyperthyroidism but there is no general agreement for the initial dose. To determine the cost-effectiveness and optimal dose of I-131 to cure disease, we prospectively studied the outcome of radioiodine therapy of 423 patients. Material and Methods: Any of the fixed doses of 6, 8, 10, 12 or 15 mCi of I-131 was administered to the patients relating to thyroid gland size. The individual was excluded from this study who had multinodular goitre and autonomous toxic nodule. Patients were classified as cured if the clinical and biochemical status was either euthyroid or hypothyroid at one year without further treatment by antithyroid drugs or radioiodine. The costs were assessed by analyzing the total cost of care including office visit, laboratory testing, radioiodine treatment, average conveyance and income loss of patient and attendant and thyroxine replacement for a period of 2 years from the day of I-131 administration. Results: The results showed a progressive increase of cure rate from the doses of 6, 8 and 10 mCi by 67%, 76.5% and 85.7% respectively but the cure rate for the doses of 12 and 15 mCi was 87.9% and 88.8% respectively. Cure was directly related to the dose between 6 and 10 mCi but at higher doses the cure rate was increased marginally at the expense of increased total body radiation. There was little variation in total costs, but was higher for low dose-therapy and the cost proportion between the 6 mCi regimen and 10 mCi regimen was 1.04:1. Conclusion: We could conclude that an initial 10 mCi of I-131 may be the optimal dose for curing hyperthyroidism and will also limit the total costs

  7. Thyroid cancer around Chernobyl

    International Nuclear Information System (INIS)

    Beral, V.

    1997-01-01

    The author's presentation on thyroid cancer around Chernobyl will focus on four different things. First will be the time trends, or the pattern of thyroid cancer occurrence before and after the accident. It is now very well known that the increase in thyroid cancer in children in several areas has been unprecedented. Second, the author discusses thyroid cancer in general and patterns of thyroid cancer around the world before the Chernobyl accident, including differences by age and pathology. Third, the author presents relatively crude analyses of risk according to dose to the thyroid gland. And last, the author attempts to contrast the findings for thyroid cancer in relation to the internal radioiodine dose in Chernobyl studies with analyses of the effects of external dose on thyroid cancer incidence. The bottom line to be developed is similar to that presented by Elaine Ron with regard to effects of external dose on thyroid cancer. The similarities between the childhood finding from Chernobyl studies and external radiation studies appear more remarkable than the differences

  8. Impact of Uncertainties in Exposure Assessment on Thyroid Cancer Risk among Persons in Belarus Exposed as Children or Adolescents Due to the Chernobyl Accident.

    Directory of Open Access Journals (Sweden)

    Mark P Little

    Full Text Available The excess incidence of thyroid cancer in Ukraine and Belarus observed a few years after the Chernobyl accident is considered to be largely the result of 131I released from the reactor. Although the Belarus thyroid cancer prevalence data has been previously analyzed, no account was taken of dose measurement error.We examined dose-response patterns in a thyroid screening prevalence cohort of 11,732 persons aged under 18 at the time of the accident, diagnosed during 1996-2004, who had direct thyroid 131I activity measurement, and were resident in the most radio-actively contaminated regions of Belarus. Three methods of dose-error correction (regression calibration, Monte Carlo maximum likelihood, Bayesian Markov Chain Monte Carlo were applied.There was a statistically significant (p0.2.In summary, the relatively small contribution of unshared classical dose error in the current study results in comparatively modest effects on the regression parameters.

  9. Effect on thyroid function and serum PTH, BGP, CT of small dose of iodine 131 combined with Methimazole in patients with hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Jia-Yin Qiu

    2016-03-01

    Full Text Available Objective: To observe the effect on thyroid function and serum PTH, BGP, CT of small dose of iodine 131 combined with Methimazole in patients with hyperthyroidism. Methods: A total of 104 patients with hyperthyroidism willing be incorporated into the study were randomly divided into the observation group (54 cases and the control group (50 cases. The control group was treated with Methimazole, and the observation group was given a small dose of iodine 131 the basised on the control group. For 2 months, to observe the changes of thyroid function (TT3, TT4, FT3, FT4 and TSH and bone metabolism related indexes (PTH, BGP and CT of the two groups. Results: (1 After treatment, TT3, FT3, TT4 and FT4 of the two groups decreased with before, and the observation group improved more significantly than the control group, with statistical difference; TSH of the two groups had no significant change. (2 After treatment, BGP and CT of the two groups decreased and PTH increased, the observation group improved more significantly than the control group, with statistical difference. Conclusion: small dose of iodine 131 combined with Methimazole can correct thyroid function and bone metabolism quickly in patients with hyperthyroidism.

  10. Effects of graded doses of goitrin, a goitrogen in rapeseed, on synthesis and release of thyroid hormone in chicks

    International Nuclear Information System (INIS)

    Akiba, Yukio; Matsumoto, Tatsuro

    1977-01-01

    Intrathyroidal metabolism in synthesis and release of thyroid hormone was investigated in chicks administered three different levels of goitrin (0.0125, 0.025 and 0.05% in the diet) for 14 days. Thyroid glands were enlarged to 2-5 times as large as that of the control in proportion to the goitrin content of the diet. Typical high radioiodine uptake goiter was demonstrated in the goitrin-administered chicks. Total thyroid 125 I content increased about twice as much as that of the control in the goitrin-administered chicks though it was depressed in 0.0065% PUT-administered chicks. Decrease of plasma PB 125 I (approximately a half of the control) was ascertained by the estimation of plasma thyroxine by radiostereoassay. In the intrathyroidal metabolism of iodine, synthesis of iodothyronines and iodination of MIT were suppressed by goitrin, but monoiodination of tyrosine was rather accelerated. The elevated ratio of thyroid iodothyronines/plasma PBI (1.5-1.7 times as much as that of the control) reveals that the depression of plasma level of thyroid hormone is more striking than the decrease in thyroid hormone in the gland in the goitrin-administered chicks. It is, therefore, suggested that goitrin has inhibitory effects not only on the biosynthesis of thyroid hormone in the gland but also on the release of thyroid hormone from the gland. (auth.)

  11. Estimation of thyroid equivalent doses during evacuation based on body surface contamination levels in the nuclear accident of FDNPS in 2011

    Science.gov (United States)

    Ohba, Takashi; Hasegawa, Arifumi; Kohayakawa, Yoshitaka; Kondo, Hisayoshi; Suzuki, Gen

    2017-09-01

    To reduce uncertainty in thyroid dose estimation, residents' radiation protection behavior should be reflected in the estimation. Screening data of body surface contamination provide information on exposure levels during evacuation. Our purpose is to estimate thyroid equivalent doses based on body surface contamination levels using a new methodology. We obtained a record of 7,539 residents/evacuees. Geiger-Mueller survey meter measurement value in cpm was translated into Bq/cm2 according to the nuclides densities obtained by measuring clothing from two persons by germanium γ-spectrometer. The measurement value of body surface contamination on head was adjusted by a natural removal rate of 15 hours and radionuclides' physical half-life. Thyroid equivalent dose of 1-year-old children by inhalation was estimated by two-dimensional Monte Carlo simulation. The proportions of evacuees/residents with measurement value in cpm of Namie and Minamisoma groups were higher than those of other groups during both periods (p<0.01, Kruskal-Wallis). During 12-14 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were estimated as 2.7 and 86.0 mSv, respectively, for Namie group, and 4.2 and 17.2 mSv, respectively, for Minamisoma group, 0.1 and 1.0 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 0.2 and 2.1 mSv, respectively, for the other group. During 15- 17 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were 0.8 and 15.7 mSv, respectively, for Namie group, and 1.6 and 8.4 mSv, respectively, for Minamisoma group, 0.2 and 13.2 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 1.2 and 12.7 mSv, respectively, for the other group. It was indicated that inhalation dose was generally higher in Namie and Minamisoma groups during 12-14 March than those during 15-17 March might reflect different self-protective behavior to radioactive plumes from other groups.

  12. Dose assessment around TR-2 reactor due to maximum credible accident

    International Nuclear Information System (INIS)

    Turgut, M. H.; Adalioglu, U.; Aytekin, A.

    2001-01-01

    The revision of safety analysis report of TR-2 research reactor had been initiated in 1995. The whole accident analysis and accepted scenario for maximum credible accident has been revised according to the new safety concepts and the impact to be given to the environment due to this scenario has been assessed. This paper comprises all results of these calculations. The accepted maximum credible accident scenario is the partial blockage of the whole reactor core which resulted in the release of 25% of the core inventory. The DOSER code which uses very conservative modelling of atmospheric distributions were modified for the assessment calculations. Pasquill conditions based on the local weather observations, topography, and building affects were considered. The thyroid and whole body doses for 16 sectors and up to 10 km of distance around CNAEM were obtained. Release models were puff and a prolonged one of two hours of duration. Release fractions for the active isotopes were chosen from literature which were realistic

  13. Radionuclide transport and dose assessment modelling in biosphere assessment 2009

    International Nuclear Information System (INIS)

    Hjerpe, T.; Broed, R.

    2010-11-01

    Following the guidelines set forth by the Ministry of Trade and Industry (now Ministry of Employment and Economy), Posiva is preparing to submit a construction license application for the final disposal spent nuclear fuel at the Olkiluoto site, Finland, by the end of the year 2012. Disposal will take place in a geological repository implemented according to the KBS-3 method. The long-term safety section supporting the license application will be based on a safety case that, according to the internationally adopted definition, will be a compilation of the evidence, analyses and arguments that quantify and substantiate the safety and the level of expert confidence in the safety of the planned repository. This report documents in detail the conceptual and mathematical models and key data used in the landscape model set-up, radionuclide transport modelling, and radiological consequences analysis applied in the 2009 biosphere assessment. Resulting environmental activity concentrations in landscape model due to constant unit geosphere release rates, and the corresponding annual doses, are also calculated and presented in this report. This provides the basis for understanding the behaviour of the applied landscape model and subsequent dose calculations. (orig.)

  14. [Assessment of thyroid function in women treated for vomiting in early pregnancy].

    Science.gov (United States)

    Makowska, Beata; Preis, Krzysztof; Swiatkowska-Freund, Małgorzata; Leszczyńska, Katarzyna

    2005-08-01

    Hyperthyroidism does not influence procreation ability significantly, but very often causes complications of the course of pregnancy and increases neonatal morbidity and mortality in newborns. Nausea and vomiting in the first trimester of pregnancy are very common complaints in these patients. The aim of the study was to prove, that assessment of the thyroid hormones in every vomiting woman in the first trimester allows to start the proper treatment of hyperthyreosis as early as possible and improves the prognosis. Authors analyzed 22 pregnant women treated for vomiting during the first trimester in the Department of Obstetrics and 5 women treated in the Outpatient Clinic. In none of them hormonal dysfunction was diagnosed before pregnancy. In 21 patients free thyroxine (fT4) in serum was assessed. In 8 cases (38%) hyperthyreosis was diagnosed. Except the routine anti vomiting treatment, they received a beta-blocker 30 mg per day. It allowed to avoid hospitalization in three pregnant women treated in the outpatient clinic. Two patients, who had earlier two spontaneous abortions, delivered healthy babies. 1. The beta-blocker in treatment gives very good results and allows to avoid hospitalization in patients with hyperthyroidism and hyper emesis gravidarum. 2. In some patients vomiting may be the only symptom of sub clinical hyperthyroidism in early pregnancy. Assessment of the thyroid hormones levels and adequate treatment may give these women a chance for a healthy child.

  15. Sonographic findings of thyroid cancer initially assessed as no suspicious malignancy

    International Nuclear Information System (INIS)

    Kim, Do Youn; Kang, Seok Seon; Ji, Eun Kyung; Kwon, Tae Hee; Park, Hae Lin; Shim, Jeong Yun

    2008-01-01

    To review the retrospective imaging findings of thyroid cancer initially assessed as no suspicious malignancy. Of 338 nodules confirmed to be thyroid cancer, this study included 38 patients with 39 nodules assessed as no suspicious malignancy on initial sonography. (mean age:39 years, 36 females and 2 males). We evaluated sonographic findings by shape, margin, echogenecity, calcification, cystic degeneration and peripheral hypoechoic rim retrospectively. We analyzed whether sonographic findings were different according to the size (standard:1 cm). The most frequent sonographic findings were avoid to round shape 90%, well-defined smooth margin 64%, hypoechogenecity 54%, no calcification 92%, no cystic degeneration 77% and peripheral hypoechoic rim 56%. Suspicious malignancy findings were taller than wide shape 10%, well-defined spiculated margin 36%, markedly hypoechogenecity 10% and microcalcifications 8%. Isoechogenecity, cystic degeneration and peripheral hypoechoic rim were common in 1 cm more than nodules. Well-defined spiculated margin was common in 1 cm less than nodules. In retrospective, 56% showed no suspicious malignancy finding. Although nodules assessed as no suspicious malignancy on initial US had many retrospectively suspicious malignancy findings, still many nodules showed no suspicious malignancy finding. Suspicious findings were ignored due to equivocal finding in small size, isoechogenecity, cystic degeneration or peripheral hypoechoic rim. We need careful observation

  16. A comparison of 1850 (50 mCi) and 3700 MBq (100 mCi) 131-iodine administered doses for recombinant thyrotropin-stimulated postoperative thyroid remnant ablation in differentiated thyroid cancer.

    Science.gov (United States)

    Pilli, Tania; Brianzoni, Ernesto; Capoccetti, Francesca; Castagna, Maria Grazia; Fattori, Sara; Poggiu, Angela; Rossi, Gloria; Ferretti, Francesca; Guarino, Elisa; Burroni, Luca; Vattimo, Angelo; Cipri, Claudia; Pacini, Furio

    2007-09-01

    Recently, a multicenter study in differentiated thyroid cancer (DTC) patients showed that 3700 MBq 131-iodine ((131)I) after recombinant human TSH (rhTSH) had a successful thyroid ablation rate similar to that obtained after thyroid hormone withdrawal. We investigated whether 1850 MBq (131)I had a similar successful rate to 3700 MBq in patients prepared with rhTSH. A total of 72 patients with DTC were randomly assigned to receive 1850 (group A, n = 36) or 3700 MBq (group B, n = 36) (131)I after rhTSH. One injection of 0.9 mg rhTSH was administered for 2 consecutive days; (131)I therapy was delivered 24 h after the last injection, followed by a posttherapy whole-body scan. Successful ablation was assessed 6-8 months later. Successful ablation (no visible uptake in the diagnostic whole-body scan after rhTSH stimulation) was achieved in 88.9% of group A and B patients. Basal and rhTSH-stimulated serum thyroglobulin was undetectable (<1 ng/ml) in 78.9% of group A and 66.6% of group B patients (P = 0.46). Similar rates of ablation were obtained in both groups also in patients with node metastases. Therapeutic (131)I activities of 1850 MBq are equally effective as 3700 MBq for thyroid ablation in DTC patients prepared with rhTSH, even in the presence of node metastases.

  17. Development of a dose assessment computer code for the NPP severe accident

    International Nuclear Information System (INIS)

    Cheong, Jae Hak

    1993-02-01

    A real-time emergency dose assessment computer code called KEDA (KAIST NPP Emergency Dose Assessment) has been developed for the NPP severe accident. A new mathematical model which can calculate cloud shine has been developed and implemented in the code. KEDA considers the specific Korean situations(complex topography, orientals' thyroid metabolism, continuous washout, etc.), and provides functions of dose-monitoring and automatic decision-making. To verify the code results, KEDA has been compared with an NRC officially certified code, RASCAL, for eight hypertical accident scenarios. Through the comparison, KEDA has been proved to provide reasonable results. Qualitative sensitivity analysis also the been performed for potentially important six input parameters, and the trends of the dose v.s. down-wind distance curve have been analyzed comparing with the physical phenomena occurred in the real atmosphere. The source term and meteorological conditions are turned out to be the most important input parameters. KEDA also has been applied to simulate Kori site and a hyperthetical accident with semi-real meteorological data has been simulated and analyzed

  18. Microdosimetric approach for lung dose assessments

    International Nuclear Information System (INIS)

    Hofmann, W.; Steinhausler, F.; Pohl, E.; Bernroider, G.

    1980-01-01

    In the macroscopic region the term ''organ dose'' is related to an uniform energy deposition within a homogeneous biological target. Considering the lung, inhaled radioactive nuclides, however, show a significant non-uniform distribution pattern throughout the respiratory tract. For the calculation of deposition and clearance of inhaled alpha-emitting radionuclides within different regions of this organ, a detailed compartment model, based on the Weibel model A was developed. Since biological effects (e.g. lung cancer initiation) are primarily caused at the cellular level, the interaction of alpha particles with different types of cells of the lung tissue was studied. The basic approach is to superimpose alpha particle tracks on magnified images of randomly selected tissue slices, simulating alpha emitting sources. Particle tracks are generated by means of a specially developed computer program and used as input data for an on-line electronic image analyzer (Quantimet-720). Using adaptive pattern recognition methods the different cells in the lung tissue can be identified and their distribution within the whole organ determined. This microdosimetric method is applied to soluble radon decay products as well as to insoluble, highly localized, plutonium particles. For a defined microdistribution of alpha emitters, the resulting dose, integrated over all cellular dose values, is compared to the compartmental doses of the ICRP lung model. Furthermore this methodology is also applicable to other organs and tissues of the human body for dose calculations in practical health physics. (author)

  19. Assessment of radiation dose awareness among pediatricians

    International Nuclear Information System (INIS)

    Thomas, Karen E.; Parnell-Parmley, June E.; Charkot, Ellen; BenDavid, Guila; Krajewski, Connie; Haidar, Salwa; Moineddin, Rahim

    2006-01-01

    There is increasing awareness among pediatric radiologists of the potential risks associated with ionizing radiation in medical imaging. However, it is not known whether there has been a corresponding increase in awareness among pediatricians. To establish the level of awareness among pediatricians of the recent publicity on radiation risks in children, knowledge of the relative doses of radiological investigations, current practice regarding parent/patient discussions, and the sources of educational input. Multiple-choice survey. Of 220 respondents, 105 (48%) were aware of the 2001 American Journal of Roentgenology articles on pediatric CT and radiation, though only 6% were correct in their estimate of the quoted lifetime excess cancer risk associated with radiation doses equivalent to pediatric CT. A sustained or transient increase in parent questioning regarding radiation doses had been noticed by 31%. When estimating the effective doses of various pediatric radiological investigations in chest radiograph (CXR) equivalents, 87% of all responses (and 94% of CT estimates) were underestimates. Only 15% of respondents were familiar with the ALARA principle. Only 14% of pediatricians recalled any relevant formal teaching during their specialty training. The survey response rate was 40%. Awareness of radiation protection issues among pediatricians is generally low, with widespread underestimation of relative doses and risks. (orig.)

  20. Sarcoidosis and Thyroid Autoimmunity

    Directory of Open Access Journals (Sweden)

    Piera Fazzi

    2017-08-01

    Full Text Available Most of the studies have shown a higher risk for subclinical and clinical hypothyroidism, antithyroid autoantibodies [overall antithyroid peroxidase antibodies (TPOAb], and in general, thyroid autoimmunity, overall in the female gender in patients with sarcoidosis (S. A significantly higher prevalence of clinical hypothyroidism and Graves’ disease was also described in female S patients with respect to controls. Gallium-67 (Ga-67 scyntigraphy in S patients, in the case of thyroid uptake, suggests the presence of aggressive autoimmune thyroiditis and hypothyroidism. For this reason, ultrasonography and thyroid function should be done in the case of Ga-67 thyroid uptake. In conclusion, thyroid function, TPOAb measurement, and ultrasonography should be done to assess the clinical profile in female S patients, and the ones at high risk (female individuals, with TPOAb positivity, and hypoechoic and small thyroid should have periodically thyroid function evaluations and suitable treatments.

  1. Risk of thyroid cancer among Chernobyl liquidators

    International Nuclear Information System (INIS)

    Evrard, Anne-Sophie; Kesminiene, Ausrele; Tenet, Vanessa; Cardis, Elisabeth; Ivanov, Viktor K.; Chekin, Sergei; Malakhova, Irina V.; Polyakov, Semion; Kurtinaitis, Juozas; Stengrevics, Aivars; Tekkel, Mare; Drozdovitch, Vladimir; Gavrilin, Yuri; Golovanov, Ivan; Krjuchkov, Viktor P.; Tukov, Aleksandr R.; Maceika, Evaldas; Mirkhaidarov, Anatoly K.

    2008-01-01

    Full text: While the increased risk of thyroid cancer is well demonstrated in people exposed to radioactive iodines in childhood and adolescence in the most contaminated areas around the Chernobyl power plant, following the accident which took place on 26 April 1986, the effect of exposure on adults remains unclear. A collaborative case-control study of thyroid cancer was set-up, nested within cohorts of Belarus, Russian and Baltic countries liquidators of the Chernobyl accident, to evaluate the radiation-induced risk of this disease among liquidators, and to assess the roles of screening and of radiation exposures in the observed increased thyroid cancer incidence among liquidators. The study population consisted of the cohorts of approximately 66,000 Belarus, 65,000 Russian and 15,000 Baltic countries liquidators who took part in the clean-up activities on the reactor site and in the 30-km zone around the Chernobyl nuclear power plant between 26 April 1986 and 31 December 1987. The liquidators were mainly exposed to external radiation, although substantial dose to the thyroid from iodine isotopes may have been received by liquidators who worked in May-June 1986 and by those who resided in the most contaminated territories of Belarus. Information was collected on study subjects by use of a standardized questionnaire that was administrated during a face-to-face interview with the study subject and/or a proxy (a relative or a colleague). The interview included questions on demographic factors, time, place and conditions of work as a liquidator and on potential risk and confounding factors for thyroid cancer. A method of analytical dose reconstruction, entitled RADRUE (Realistic Analytical Dose Reconstruction with Uncertainty Estimation) was developed within the study and applied to estimate individual doses to the thyroid from external radiation and related uncertainties for each subject. Approaches to derive individual thyroid dose estimates from inhaled and

  2. Prospective randomized trial for the evaluation of the efficacy of low vs. high dose I-131 for post operative remnant ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Barrenechea, E.A.; Laureta, E.G.; Gaston, J.C.; Al-Nahhas, A.; Padhy, A.K.

    2005-01-01

    The study was done under the auspices of the IAEA to evaluate the efficacy of low dose (50-60mCi) vs. High dose (100 mCi) for the post-operative remnant ablation of differentiated thyroid cancer and to determine other factors associated with successful ablation. There were eighty-six patients included in the study with a diagnosis of papillary, follicular or mixed type of thyroid cancer. They all have undergone near total thyroidectomy or total thyroidectomy and without any evidence of metastatic disease. Four to six weeks after the surgery and without thyroid hormone maintenance as well as iodine free diet and drugs, they underwent a total body scan and uptake using 1-3 mci of I-131. Serum TSH and thyroglobulin were also taken. Randomization was made thru the IAEA and the patients either got a low dose or a high dose depending on such randomization. Of the 86 patients included, there were a total of 76 evaluable cases. There were three dropouts because of other medical conditions as upper GI bleeding, lung cancer and leg fracture. The 7 other patients have not completed their follow-up body scan. Among these patients were 67 females and 19 males whose age range was 19 to 84 years old. There were 65 cases with histologic type of papillary cancer, 15 follicular and 6 mixed varieties. Forty-one patients were randomized to the high dose group while 35 patients were assigned to the low dose therapy group. These patients were confined till their radiation activity was below 2mR/hr. Monitoring of the patients were done during their hospital stay. Post-therapy body scan was done but not with all patients. Most of the side effects noted were sialitis, mild neck pains, nausea and occasional vomiting as well as ageusia. These patients were maintained on thyroid hormone depending on their sensitivity but almost all were given 200-300mgs per day. The older patients tolerated only around 150mcgs/day. After four to six months, serum TSH, thyroglobulin and total body scan were

  3. Assessment of low absorbed dose with a MOSFET detector

    International Nuclear Information System (INIS)

    Butson, M.J.; Cancer Services, Wollongong, NSW; Cheung, T.; Yu, P.K.N.

    2004-01-01

    Full text: The ability of a MOSFET dosimetry system to measure low therapeutic doses has been evaluated for accuracy for high energy x-ray radiotherapy applications. The MOSFET system in high sensitivity mode produces a dose measurement reproducibility of within 10%, 4% and 2.5% for 2 cGy, 5 cGy and 10cGy dose assessment respectively. This is compared to 7%, 4% and 2% for an Attix parallel plate ionisation chamber and 20%, 7% and 3.5% for a Wellhofer IC4 small volume ionisation chamber. Results for our dose standard thimble ionisation chamber and low noise farmer dosemeter were 2%, 0.5% and 0.25% respectively for these measurements. The quoted accuracy of the MOSFET dosimetry system is partially due to the slight non linear dose response (reduced response) with age of the detector but mainly due to the intrinsic variations in measured voltage differential per applied dose. Results have shown that the MOSFET dosimetry system provides an adequate measure of dose at low dose levels and is comparable in accuracy to the Attix parallel plate ionisation chambers for relative dose assessment at levels of 2cGy to 10cGy. The use of the MOSFET dosimeter at low doses can extend the life expectancy of the device and may provide useful information for areas where low dose assessment is required. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  4. Dose assessment for decontamination in Goiania

    International Nuclear Information System (INIS)

    Amaral, E.C.S.

    2000-01-01

    Shortly after the accident at Goiania, the need arose to set derived intervention levels for the various exposure pathways to guide and optimise clean up measures. For the members of the critical group an intervention level of 5 mSv for the total effective dose in the first year after the accident was chosen, which then was subdivided into values of 1 mSv due to the contribution of external irradiation indoors, 3 mSv from external irradiation while being outdoors, and 1 mSv due to incorporation of resuspended particles and ingestion of locally produced food. The clean up indoors could be directed such that a pre-described ambient dose rate was no longer exceeded. These exposure levels and effective doses to the critical groups predicted in 1988 are compared to actual measurements made in 1988 to 1993 in a local house near one primary contamination foci, and best estimate. It can be shown that the actual doses received by members of the public living in the affected areas were significantly lower. The various reasons for this overprediction will be discussed. (author)

  5. Going beyond the most exposed people in a dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hjerpe, Thomas; Broed, Robert [Facilia AB, Gustavslundsvaegen 151C, SE-167 51 Bromma (Sweden); Ikonen, Ari T.K. [Environmental Research and Assessment, EnviroCase, Ltd., Hallituskatu 1 D 4, FI-28 100 Pori (Finland)

    2014-07-01

    The dose assessment in a long-term radiation safety assessment often focus on assessing dose of a representative person to be used for determining compliance with a radiation dose constraint. This representative person is often assumed to receive a dose that is representative of the most exposed people, i.e., the more highly exposed individuals in the population. This is not always sufficient, the Finnish regulations for disposal of nuclear waste has radiation dose constraint to the most exposed people as well as for larger groups of exposed people. This work presents the methodology to assessing dose of a representative person for a larger group of exposed people as applied by Posiva in the TURVA-2012 safety case for the spent nuclear fuel disposal at Olkiluoto. In addition, annual doses from the set of biosphere calculation cases analysed in TURVA-2012 are presented and discussed. Special focus is given on explaining the differences in exposure levels and exposure routes between the estimated annual doses to representative persons for most exposed people and a larger exposed group. The results show that the annual doses to a larger group of people ranges from one to three orders of magnitude below the annual doses to the most exposed people. Furthermore, the exposure route related to food ingestion is less significant for the larger group of people compared to the most exposed people and that the exposure route related to water ingestion shows the opposite behaviour. (authors)

  6. A review of occupational dose assessment uncertainties and approaches

    International Nuclear Information System (INIS)

    Anderson, R. W.

    2004-01-01

    The Radiological Protection Practitioner (RPP) will spend a considerable proportion of his time predicting or assessing retrospective radiation exposures to occupational personnel for different purposes. The assessments can be for a variety of purposes, such as to predict doses for occupational dose control, or project design purposes or to make retrospective estimates for the dose record, or account for dosemeters which have been lost or damaged. There are other less frequent occasions when dose assessment will be required such as to support legal cases and compensation claims and to provide the detailed dose information for epidemiological studies. It is important that the level of detail, justification and supporting evidence in the dose assessment is suitable for the requirements. So for instance, day to day operational dose assessments often rely mainly on the knowledge of the RPP in discussion with operators whilst at the other end of the spectrum a historical dose assessment for a legal case will require substantial research and supporting evidence for the estimate to withstand forensic challenge. The robustness of the assessment will depend on many factors including a knowledge of the work activities, the radiation dose uptake and field characteristics; all of which are affected by factors such as the time elapsed, the memory of operators and the dosemeters employed. This paper reviews the various options and uncertainties in dose assessments ranging from use of personal dosimetry results to the development of upper bound assessments. The level of assessment, the extent of research and the evidence adduced should then be appropriate to the end use of the estimate. (Author)

  7. Thyroid autoimmunity

    NARCIS (Netherlands)

    Wiersinga, Wilmar M.

    2014-01-01

    Autoimmune thyroid disease (AITD) is a multifactorial disease in which autoimmunity against thyroid antigens develops against a particular genetic background facilitated by exposure to environmental factors. Immunogenicity of the major thyroid antigens thyroid peroxidase, thyroglobulin (TG) and

  8. Assessment of fetal activity concentration and fetal dose for selected radionuclides based on animal and human data

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1987-01-01

    Biokinetic data of selected radionuclide compounds from investigations in man and animal were taken from literature references with the purpose to provide a basis for a comparative assessment of fetal and adult radiation doses after intake or administration of radionuclides. The following ratios of fetal to adult doses were derived from human data: 0.5 for caesium 137 and total body, 2.3 for iron 59 and liver, 0.06 - 0.3 - 1.1 for iodine 131 and thyroid, and 0.1 - 0.3 for strontium 90 and bone. The ratios of activity concentrations in fetal and adult tissues are of considerable variability - up to three orders of magnitude. Further studies on fetal and adult biokinetics specifically designed for comparative dose assessment are indispensable. 106 refs.; 6 tabs

  9. External quality control assessment of thyroid related hormones in India. Final report for the period 1 December 1983 - 31 January 1988

    International Nuclear Information System (INIS)

    Shah, D.H.; Kumar, A.; Rajan, M.G.R.; Thakare, U.R.; Sharma, S.M.

    1989-11-01

    An external quality assessment scheme for thyroid related hormones was undertaken to assess the performance of various laboratories in India. The programme was conducted in two phases. The report summarizes the findings obtained on performances of the laboratories for radioimmunoassay of thyroid related hormones over the two phases. Figs and tabs

  10. IAEA/IDEAS intercomparison exercise on internal dose assessment

    International Nuclear Information System (INIS)

    Doerfel, H.; Andrasi, A.; Cruz-Suarez, R.; Castellani, C. M.; Hurtgen, C.; Marsh, J.; Zeger, J.

    2007-01-01

    An Internet based intercomparison exercise on assessment of occupational exposure due to intakes of radionuclides has been performed to check the applicability of the 'General Guidelines for the Assessment of Internal Dose from Monitoring Data' developed by the IDEAS group. There were six intake cases presented on the Internet and 81 participants worldwide reported solutions to these cases. Results of the exercise indicate that the guidelines have a positive influence on the methodologies applied for dose assessments and, if correctly applied, improve the harmonisation of assessed doses. (authors)

  11. Eye lens exposure to medical staff performing electrophysiology procedures: dose assessment and correlation to patient dose

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, Olivera; Bozovic, Predrag; Arandjic, Danijela; Antic, Vojislav; Selakovic, Jovana; Pavlovic, Sinisa

    2016-01-01

    The purpose of this study was to assess the patient exposure and staff eye dose levels during implantation procedures for all types of pacemaker therapy devices performed under fluoroscopic guidance and to investigate potential correlation between patients and staff dose levels. The mean eye dose during pacemaker/defibrillator implementation was 12 μSv for the first operator, 8.7 μSv for the second operator/nurse and 0.50 μSv for radiographer. Corresponding values for cardiac re-synchronisation therapy procedures were 30, 26 and 2.0 μSv, respectively. Significant (p < 0.01) correlation between the eye dose and the kerma-area product was found for the first operator and radiographers, but not for other staff categories. The study revealed eye dose per procedure and eye dose normalised to patient dose indices for different staff categories and provided an input for radiation protection in electrophysiology procedures. (authors)

  12. Personal monitoring and assessment of doses received by radiation workers

    International Nuclear Information System (INIS)

    Swindon, T.N.; Morris, N.D.

    1981-12-01

    The Personal Radiation Monitoring Service operated by the Australian Radiation Laboratory is outlined and the types of monitors used for assessment of doses received by radiation workers are described. The distribution of doses received by radiation workers in different occupational categories is determined. From these distributions, the average doses received have been assessed and the maximum likely additional increase in cancer deaths in Australia as a result of occupational exposure estimated. This increase is shown to be very small. There is, however, a considerable spread of doses received by individuals within occupational groups

  13. An Internal Dose Assessment Associated with Personal Food Intake

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joeun; Jae, Moosung [Hanyang University, Seoul (Korea, Republic of); Hwang, Wontae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    ICRP (International Commission on Radiological Protection), Therefore, had recommended the concept of 'Critical Group'. Recently the ICRP has recommended the use of 'Representative Person' on the new basic recommendation 103. On the other hand the U.S. NRC (Nuclear Regulatory Commission) has adopted more conservative concept, 'Maximum Exposed Individuals (MEI)' of critical Group. The dose assessment in Korea is based on MEI. Although dose assessment based on MEI is easy to receive the permission of the regulatory authority, it is not efficient. Meanwhile, the internal dose by food consumption takes an important part. Therefore, in this study, the internal dose assessment was performed in accordance with ICRP's new recommendations. The internal dose assessment was performed in accordance with ICRP's new recommendations. It showed 13.2% decreased of the annual internal dose due to gaseous effluents by replacing MEI to the concept of representative person. Also, this calculation based on new ICRP's recommendation has to be extended to all areas of individual dose assessment. Then, more accurate and efficient values might be obtained for dose assessment.

  14. Characteristics of environmental gamma-rays and dose assessment

    International Nuclear Information System (INIS)

    Saito, Kimiaki; Moriuchi, Shigeru

    1986-01-01

    Environmental radioactivity has attracted much attention in terms of exposure to the population, although its exposure doses are minimal. This paper presents problems encountered in the assessment of exposure doses using model and monitoring systems, focusing on the characteristics, such as energy distribution, direction distribution, and site, of environmental gamma-rays. The assessment of outdoor and indoor exposure doses of natural gamma-rays is discussed in relation to the shielding effect of the human body. In the assessment of artificial gamma-rays, calculation of exposure doses using build-up factor, the shielding effect of the human body, and energy dependency of the measuring instrument are covered. A continuing elucidation about uncertainties in dose assessment is emphasized. (Namekawa, K.)

  15. Values of iodine metabolism biomarkers in assessing the iodine nutrition status in surgically treated patients with thyroid disease.

    Science.gov (United States)

    Han, Jian-hua; Wu, Lian; Yu, Song-lin; Fang, Hui-ling; Kamg, Wei-ming; Cheng, Xin-qi; Lu, Jie; Yu, Jian-chun; Qiu, Ling

    2015-04-01

    To assess the clinical application value of iodine metabolism biomarkers in assessing iodine nutrition status in surgically treated patients with thyroid disease. Blood,morning urine and 24-hour urine samples were collected in 31 healthy volunteers and in 30 surgically treated patients with thyroid disease before and after surgery. Iodine concentration was analyzed by inductively coupled plasma mass spectrometry. The iodine metabolism biomarkers including serum iodine (SI), morning urine iodine(UI), morning urine iodine/urine creatinine ratio (UI/UCr), 24-hour urine iodine (24 h UI), and 24-hour urine iodine excretion (24 h UIE) were evaluated in these two groups. In addition, the validation coincidence rate of iodine metabolism biomarkers in healthy volunteers to different reference ranges including World Health Organization, Mayo Clinic, and Quest Diagnostics were calculated. The UI/UCr ratio of pre-operative thyroid disease patients was significantly lower than that of healthy volunteers (P0.05) between these two groups. The SI, UI ,and 24 h UI in postoperative thyroid disease patients were significantly higher than those of the pre-operative patients (all Piodine metabolism biomarkers. The UI/UCr ratio may be used for iodine nutrition evaluation in surgically treated patients with thyroid disease.

  16. Monitoring requirements for assessment of internal dose

    International Nuclear Information System (INIS)

    Eckerman, K.F.

    1985-01-01

    Data obtained by routine personnel monitoring is usually not a sufficient basis for estimation of dose. Collected data must be interpreted carefully and supplemented with appropriate information before reasonably accurate estimates of dose (i.e., accurate enough to indicate whether or nor personnel are exposed in excess of recommended limits) can be developed. When the exposure is of sufficient magnitude that a rather precise estimate of dose is needed, the health physicist will bring to bear on the problem other, more refined, methods of dosimetry. These might include a reconstruction of the incident and, for internal emitters, an extensive series of in vivo measurements or analyses of excreta. Thus, cases of special significance must often be evaluated using techniques and resources beyond those routinely employed. This is not a criticism of most routine monitoring programs. These programs are usually carefully designed in a manner commensurate with the degree of exposure routinely encountered and the requirement of a practical program of radiation protection. 10 refs

  17. [CONTROVERSIES REGARDING THE ACCURACY AND LIMITATIONS OF FROZEN SECTION IN THYROID PATHOLOGY: AN EVIDENCE-BASED ASSESSMENT].

    Science.gov (United States)

    Stanciu-Pop, C; Pop, F C; Thiry, A; Scagnol, I; Maweja, S; Hamoir, E; Beckers, A; Meurisse, M; Grosu, F; Delvenne, Ph

    2015-12-01

    Palpable thyroid nodules are present clinically in 4-7% of the population and their prevalence increases to 50%-67% when using high-resolution neck ultrasonography. By contrast, thyroid carcinoma (TC) represents only 5-20% of these nodules, which underlines the need for an appropriate approach to avoid unnecessary surgery. Frozen section (PS) has been used for more than 40 years in thyroid surgery to establish the diagnosis of malignancy. However, a controversy persists regarding the accuracy of FS and its place in thyroid pathology has changed with the emergence of fine-needle aspiration (FNA). A PubMed Medline and SpringerLink search was made covering the period from January 2000 to June 2012 to assess the accuracy of ES, its limitations and indications for the diagnosis of thyroid nodules. Twenty publications encompassing 8.567 subjects were included in our study. The average value of TC among thyroid nodules in analyzed studies was 15.5 %. ES ability to detect cancer expressed by its sensitivity (Ss) was 67.5 %. More than two thirds of the authors considered PS useful exclusively in the presence of doubtful ENA and for guiding the surgical extension in cases confirmed as malignant by FNA; however, only 33% accepted FS as a routine examination for the management of thyroid nodules. The influence of FS on surgical reintervention rate in nodular thyroid pathology was considered to be negligible by most studies, whereas 31 % of the authors thought that FS has a favorable benefit by decreasing the number of surgical re-interventions. In conclusion, the role of FS in thyroid pathology evolved from a mandatory component for thyroid surgery to an optional examination after a pre-operative FNA cytology. The accuracy of FS seems to provide no sufficient additional benefit and most experts support its use only in the presence of equivocal or suspicious cytological features, for guiding the surgical extension in cases confirmed as malignant by FNA and for the

  18. Thyroid nodule

    International Nuclear Information System (INIS)

    McKenney, J.F.

    1975-01-01

    A palpable mass or nodule may represent any one of a large and diverse group of conditions that involve the thyroid. Whether the patient is euthyroid, hypothyroid, or hyperthyroid can be assessed, and the cause of hypofunction or hyperfunction can usually be determined. Scintiscanning provides important information on the anatomic structure of thyroid nodules. A hot nodule should be ablated by either radioiodine or surgery. A warm nodule usually responds to suppression therapy; if regression does not occur, the problem should be reevaluated. A cold nodule should be surgically excised, as microscopic study of such a lesion is mandatory

  19. Thyroid Surgery

    Science.gov (United States)

    ... Hypothyroidism in Children and Adolescents Pediatric Differentiated Thyroid Cancer Thyroid Nodules in Children and Adolescents Thyroid Surgery Resources Thyroid Surgery Brochure PDF Thyroid Surgery FAQs PDF En Español Cirugia De La Tiroides El folleto de Cirugia De La Tiroides Search Thyroid ...

  20. A structural abnormality associated with graded levels of thyroid hormone insufficiency: Dose dependent increases in heterotopia volume

    Science.gov (United States)

    A large number of environmental contaminants reduce circulating levels of thyroid hormone (TH), but clear markers of neurological insult associated with modest TH insufficiency are lacking. We have previously identified the presence of an abnormal cluster of misplaced neurons in ...

  1. Evolution of thyroid cancer occurrence in metropolitan France. Assessment over 25 years

    International Nuclear Information System (INIS)

    Rogel, Agnes; Caserio-Schonemann, Celine; Cherie-Challine, Laurence; Rudant, Jeremie; Bloch, Juliette; Thuret, Anne; Colonna, Marc; Uhry, Zoe; Kudjawu, Yao; Danzon, Arlette; Lacour, Brigitte; Schvartz, Claire; Pascal, Laurence; Lasalle, Jean-Luc; Borson-Chazot, Francoise; Sassolas, Genevieve; Hafdi-Nejjari, Zakia; Boutron-Ruault, Marie-Christine; Guenel, Pascal; Vathaire, Florent de; Guillas, Gwenaelle; Mesrine, Sylvie; Clavel-Chapelon, Francoise; Clero, Enora; Adjadj, Elisabeth; Bedouche, Lallia; Belot, Aurelien; Fieffe, Sandrine; Dalac, Audrey; Goncalves, Katia; Kaplan, Martine; Pochart, Jean-Marie; Desenclos, Jean-Claude

    2011-04-01

    After a presentation of the epidemiological context of thyroid cancer in France, this report, based on cancer record data, analyzes the occurrence of thyroid cancers between 1982 and 2006. It discusses the contribution and limits of medical-administrative data for the epidemiological monitoring of thyroid cancer occurrence between 1997 and 2009. It proposes a descriptive analysis of thyroid cancers in two districts (Marne and Ardennes) between 1975 and 2008, and a descriptive analysis of thyroid cancer for children under 14 between 2000 and 2008. It proposes an estimation of thyroid cancer occurrence in Corsica between 1998 and 2006. It reports and discusses a pilot study performed in two regions (Ile de France and Nord Pas-de-Calais), based on a multi-source system of cancer monitoring (SMSC), and comments studies on risk factors for differentiated thyroid cancers in France

  2. Ultrasound Evaluation of Thyroid Gland Pathologies After Radiation Therapy and Chemotherapy to Treat Malignancy During Childhood

    Energy Technology Data Exchange (ETDEWEB)

    Lollert, André, E-mail: andre.lollert@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Medical Center of the Johannes Gutenberg University, Mainz (Germany); Gies, Christina; Laudemann, Katharina [Department of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Medical Center of the Johannes Gutenberg University, Mainz (Germany); Faber, Jörg [Department of Pediatrics and Adolescent Medicine, Medical Center of the Johannes Gutenberg University, Mainz (Germany); Jacob-Heutmann, Dorothee [Department of Radio-oncology and Radiotherapy, Medical Center of the Johannes Gutenberg University, Mainz (Germany); König, Jochem [Institute for Medical Biostatistics, Epidemiology and Informatics, Medical Center of the Johannes Gutenberg University, Mainz (Germany); Düber, Christoph; Staatz, Gundula [Department of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Medical Center of the Johannes Gutenberg University, Mainz (Germany)

    2016-01-01

    Purpose: The purpose of this study was to evaluate correlations between treatment of malignancy by radiation therapy during childhood and the occurrence of thyroid gland pathologies detected by ultrasonography in follow-up examinations. Methods and Materials: Reductions of thyroid gland volume below 2 standard deviations of the weight-specific mean value, occurrence of ultrasonographically detectable thyroid gland pathologies, and hypothyroidism were retrospectively assessed in 103 children and adolescents 7 months to 20 years of age (median: 7 years of age) at baseline (1997-2013) treated with chemoradiation therapy (with the thyroid gland dose assessable) or with chemotherapy alone and followed by ultrasonography and laboratory examinations through 2014 (median follow-up time: 48 months). Results: A relevant reduction of thyroid gland volume was significantly correlated with thyroid gland dose in univariate (P<.001) and multivariate analyses for doses above 2 Gy. Odds ratios were 3.1 (95% confidence interval: 1.02-9.2; P=.046) for medium doses (2-25 Gy) and 14.8 (95% confidence interval: 1.4-160; P=.027) for high doses (>25 Gy). Thyroid gland dose was significantly higher in patients with thyroid gland pathologies during follow-up (P=.03). Univariate analysis revealed significant correlations between hypothyroidism and thyroid gland dose (P<.001). Conclusions: Ultrasonographically detectable changes, that is, volume reductions, pathologies, and hypothyroidism, after malignancy treatment during childhood are associated with thyroid gland dose. Both ultrasonography and laboratory follow-up examinations should be performed regularly after tumor therapy during childhood, especially if the treatment included radiation therapy.

  3. An engagement factor for caregiver radiation dose assessment with radioiodine treatment

    International Nuclear Information System (INIS)

    Lee, Hyun Kuk; Hong, Seong Jong; Jeong, Kyu Hwan; Jung, Jae Won; Kim, Seong Min; Kang, Yun-Hee; Han, Man Seok

    2015-01-01

    This study aims to suggest ways to better manage thyroid cancer patients treated with high- and low-activity radioiodine ( 131 I) by assessing external radiation doses to family members and caregivers and the level of radiation in the surrounding environment. The radiation doses to caregivers of 33 inpatients (who were quarantined in the hospital for 2-3 d after treatment) and 31 outpatients who received radioiodine treatment after thyroidectomy were measured using passive thermoluminescence dosemeters. In this study, 33 inpatients were administered high-activity (100-200 mCi) 131 I, and 31 outpatients were administered low-activity (30 mCi) 131 I. The average doses to caregivers were measured at 0.61 mSv for outpatients and 0.16 mSv for inpatients. The total integrated dose of the recovery (recuperation) rooms where the patients stayed after release from hospital was measured to be 0.83 mSv for outpatients and 0.23 mSv for inpatients. To reflect the degree of engagement between the caregiver and the patient, considering the duration and distance between two during exposure, the authors used the engagement factor introduced by Jeong et al. (Estimation of external radiation dose to caregivers of patients treated with radioiodine after thyroidectomy. Health Phys 2014;106:466-474.). This study presents a new engagement factor (K-value) of 0.82 obtained from the radiation doses to caregivers of both in- and out-patients treated with high- and low-activity radioiodine, and based on this new value, this study presented a new predicted dose for caregivers. A patient treated with high-activity radioiodine can be released after 24 h of isolation, whereas outpatients treated with low-activity radioiodine should be isolated for at least 12 h. (authors)

  4. Determination of the concentration of thyroid hormone in dialysate and assessment of the loss of thyroid hormone during hemodialysis

    International Nuclear Information System (INIS)

    Beyer, H.K.; Schuster, P.; Pressler, H.; Bochum Univ.

    1980-01-01

    In order to determine the hormone concentration in a dialysate, the commercially available radioimmunossay test of Dow-Lepetit for determination of free thyroid hormones in serum had to be modified. The results raised the suspicion that additional protein-bound hormone had passed the membrane. This could be demonstrated by the addition of Thiomersal. In 64 patients examined 1 and 5 hrs after the beginning of hemodialysis the mean total hormone concentration in the dialysate was 12.05 pg/ml for thyroxine and 5.47 pg/ml for triiodothyronine. The resulting loss of total hormone in hemodialysis patients, calculated for 1 week, amounted to 2.25 μg triiodothyronine and 4.87 μg thyroxine. The comparison with the physiologic renal elimination of thyroid hormone shows that the hormone elimination in hemodialysis patients is negligibly small. The quantitative determination of the protein concentration in the dialysate however, that the loss of protein is without clinical relevance. (orig.) [de

  5. Value of the Serum Thyroglobulin Level Alteration at the First High Dose Radioiodine Treatment in Patients with Differentiated Thyroid Carcinoma

    International Nuclear Information System (INIS)

    Nam, Hyun Yeol; Kim, In Joo; Kim, Yong Ki; Kim, Seong Jang; Jun, Sung Min; Kim, Bum Soo

    2009-01-01

    The purpose of this study was to evaluate if short-term serum thyroglobulin (Tg) elevation after radioiodine administration can predict successful radioiodine remnant ablation (RRA) and whether comparable RRA effectiveness is exhibited between a group administered with recombinant human thyrotropin (rhTSH) and a group experiencing thyroid hormone withdrawal (THW), in preparation for RRA. A retrospective chart review was performed on 39 patients in the rhTSH group and 46 patients in the THW group. They were treated for differentiated thyroid carcinoma by total or near total thyroidectomy, and referred for RRA between 2003 and 2006 (the rhTSH group) and between January and June of 2006 (the THW group). They were assessed for serum Tg levels just before I-131 administration (TgD0), reassessed 9 days later (TgD9), and again 6-12 months later. RRA was successful in 64 (37 from the THW group and 27 from the rhTSH group) of the total 85 patients. The success rates of RRA had no statistically significant differences between the two groups. In both groups, TgD9/TgD0 values were significantly higher in the RRA success group (the rhTSH group; P=0.03, the THW group; P=0.04). By combining cutoff values of TgD0 and TgD9/TgD0, the successful RRA value was determined to be 96.7% (29/30) with TgD0≤5.28 ng/mL and TgD9/TgD0>4.37 in both groups (the rhTSH group; 100% (16/16), the THW group; 92.9% (13/14)). Using logistic multivariate analysis, only TgD0 was independently associated with successful RRA. We may predict successful ablation by evaluating short-term serum Tg elevation after I-131 administration for RRA, in both rhTSH and THW patients

  6. Integration of a radiation biomarker into modeling of thyroid carcinogenesis and post-Chernobyl risk assessment.

    Science.gov (United States)

    Kaiser, Jan Christian; Meckbach, Reinhard; Eidemüller, Markus; Selmansberger, Martin; Unger, Kristian; Shpak, Viktor; Blettner, Maria; Zitzelsberger, Horst; Jacob, Peter

    2016-12-01

    Strong evidence for the statistical association between radiation exposure and disease has been produced for thyroid cancer by epidemiological studies after the Chernobyl accident. However, limitations of the epidemiological approach in order to explore health risks especially at low doses of radiation appear obvious. Statistical fluctuations due to small case numbers dominate the uncertainty of risk estimates. Molecular radiation markers have been searched extensively to separate radiation-induced cancer cases from sporadic cases. The overexpression of the CLIP2 gene is the most promising of these markers. It was found in the majority of papillary thyroid cancers (PTCs) from young patients included in the Chernobyl tissue bank. Motivated by the CLIP2 findings we propose a mechanistic model which describes PTC development as a sequence of rate-limiting events in two distinct paths of CLIP2-associated and multistage carcinogenesis. It integrates molecular measurements of the dichotomous CLIP2 marker from 141 patients into the epidemiological risk analysis for about 13 000 subjects from the Ukrainian-American cohort which were exposed below age 19 years and were put under enhanced medical surveillance since 1998. For the first time, a radiation risk has been estimated solely from marker measurements. Cross checking with epidemiological estimates and model validation suggests that CLIP2 is a marker of high precision. CLIP2 leaves an imprint in the epidemiological incidence data which is typical for a driver gene. With the mechanistic model, we explore the impact of radiation on the molecular landscape of PTC. The model constitutes a unique interface between molecular biology and radiation epidemiology. © The Author 2016. Published by Oxford University Press.

  7. Measurement of the Dose to the Family Members Taking Care of Thyroid Cancer Patients Undergoing I-131 Therapy in Nuclear Medicine Using TLD-100.

    Science.gov (United States)

    Zehtabian, M; Dehghan, N; Danaei Ghazanfarkhani, M; Haghighatafshar, M; Sina, S

    2017-05-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by 131I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commitions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Measurement of the dose to the family members taking care of thyroid cancer patients undergoing I-131 therapy in nuclear medicine using TLD-100

    International Nuclear Information System (INIS)

    Zehtabian, M.; Dehghan, N.; Danaei Ghazanfarkhani, M.; Haghighatafshar, M.; Sina, S.

    2017-01-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by "1"3"1I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commissions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. (authors)

  9. The influence of saliva flow stimulation on the absorbed radiation dose to the salivary glands during radioiodine therapy of thyroid cancer using 124I PET(/CT) imaging

    International Nuclear Information System (INIS)

    Jentzen, Walter; Schmitz, Jochen; Freudenberg, Lutz; Eising, Ernst; Bockisch, Andreas; Stahl, Alexander; Balschuweit, Dorothee; Hilbel, Thomas

    2010-01-01

    A serious side effect of high-activity radioiodine therapy in the treatment of differentiated thyroid cancer is radiogenic salivary gland damage. This damage may be diminished by lemon-juice-induced saliva flow immediately after 131 I administration. The aim of this study was to assess the effect of chewing lemon slices on the absorbed (radiation) doses to the salivary glands. Ten patients received (pretherapy) 124 I PET(/CT) dosimetry before their first radioiodine therapy. The patients underwent a series of six PET scans at 0.5, 1, 2, 4, 48 and ≥96 h and one PET/CT scan at 24 h after administration of 27 MBq 124 I. Blood samples were also collected at about 2, 4, 24, 48, and 96 h. Contrary to the standard radioiodine therapy protocol, the patients were not stimulated with lemon juice. Specifically, the patients chewed no lemon slices during the pretherapy procedure and neither ate food nor drank fluids until after completion of the last PET scan on the first day. Organ absorbed doses per administered 131 I activity (ODpAs) as well as gland and blood uptake curves were determined and compared with published data from a control patient group, i.e. stimulated per the standard radioiodine therapy protocol. The calculations for both groups used the same methodology. A within-group comparison showed that the mean ODpA for the submandibular glands was not significantly different from that for the parotid glands. An intergroup comparison showed that the mean ODpA in the nonstimulation group averaged over both gland types was reduced by 28% compared to the mean ODpA in the stimulation group (p=0.01). Within each gland type, the mean ODpA reductions in the nonstimulation group were statistically significant for the parotid glands (p=0.03) but not for the submandibular glands (p=0.23). The observed ODpAs were higher in the stimulation group because of increased initial gland uptake rather than group differences in blood kinetics. The 124 I PET(/CT) salivary gland

  10. Radiation protection to the eye and thyroid during diagnostic cerebral angiography: a phantom study.

    LENUS (Irish Health Repository)

    Shortt, C P

    2008-08-01

    We measured radiation doses to the eye and thyroid during diagnostic cerebral angiography to assess the effectiveness of bismuth and lead shields at dose reduction. Phantom head angiographic studies were performed with bismuth (study 1) and lead shields (study 2). In study 1 (12 phantoms), thermoluminescent dosimeters (TLD) were placed over the eyes and thyroid in three groups: (i) no shields (four phantoms); (ii) anterior bismuth shields (four phantoms) and (iii) anterior and posterior bismuth shields (four phantoms). In a second study (eight phantoms), lead shields were placed over the thyroid only and TLD dose measurements obtained in two groups: (i) no shielding (four phantoms) and (ii) thyroid lead shielding (four phantoms). A standard 4-vessel cerebral angiogram was performed on each phantom. Study 1 (bismuth shields) showed higher doses to the eyes compared with thyroid (mean 13.03 vs 5.98 mSv, P < 0.001) and a higher eye dose on the X-ray tube side. Overall, the use of bismuth shielding did not significantly reduce dose to either eyes or thyroid in the measured TLD positions. In study 2, a significant thyroid dose reduction was found with the use of lead shields (47%, mean 2.46 vs 4.62 mSv, P < 0.001). Considerable doses to the eyes and thyroid highlight the need for increased awareness of patient protection. Eye shielding is impractical and interferes with diagnostic capability. Thyroid lead shielding yields significant protection to the thyroid, is not in the field of view and should be used routinely.

  11. Radiation protection to the eye and thyroid during diagnostic cerebral angiography : a phantom study

    International Nuclear Information System (INIS)

    Shortt, C. P.; Malone, L.; Thornton, J.; Brennan, P.; Lee, M. J.

    2008-01-01

    Full text: We measured radiation doses to the eye and thyroid during diagnostic cerebral angiography to assess the effectiveness of bismuth and lead shields at dose reduction. Phantom head angiographic studies were performed with bismuth (study 1) and lead shields (study 2). In study 1 (12 phantoms), thermoluminescent dosimeters (TLD) were placed over the eyes and thyroid in three groups: (i) no shields (four phantoms); (ii) anterior bismuth shields (four phantoms) and (iii) anterior and posterior bismuth shields (four phantoms). In a second study (eight phantoms), lead shields were placed over the thyroid only and TLD dose measurements obtained in two groups: (i) no shielding (four phantoms) and (ii) thyroid lead shielding (four phantoms). A standard 4-vessel cerebral angiogram was performed on each phantom. Study 1 (bismuth shields) showed higher doses to the eyes compared with thyroid (mean 13.03 vs 5.98 mSv, P < 0.001) and a higher eye dose on the X-ray tube side. Overall, the use of bismuth shielding did not significantly reduce dose to either eyes or thyroid in the measured TLD positions. In study 2, a significant thyroid dose reduction was found with the use of lead shields (47%, mean 2.46 vs 4.62 mSv, P < 0.001). Considerable doses to the eyes and thyroid highlight the need for increased awareness of patient protection. Eye shielding is impractical and interferes with diagnostic capability. Thyroid lead shielding yields significant protection to the thyroid, is not in the field of view and should be used routinely.

  12. Assessment of thyroid hormones, insulin and magnesium in dairy cattle with subclinical ketosis

    Directory of Open Access Journals (Sweden)

    A Sadeghi-nasab

    2011-08-01

    Full Text Available Ketosis, with ethologically energy deficiency, is one of the commonest metabolic diseases of dairy cattle. Assessment of some serum hormonal and metabolic status can be beneficent in prediction and diagnosis of subclinical ketosis. This study is performed for evaluation and comparison of thyroid hormones, insulin and magnesium of subclinical ketosis and healthy cows. During 60 days in milk (DIM serum Beta hydroxy butyric acid (BHBA and glucose levels of 200 dairy cattle have been measured. Based on 1.4 mmol/l of BHBA as a cut of point experimented animals separated to subclinical and healthy groups. Mean values of serum T3 and T4 of affected cows were significantly higher than non-affected (p

  13. Association of Papillary Thyroid Carcinoma and Graves' Disease. Unexpected Development and Efficiency of Ablative Dose with Recombinant Human Thyrotropin (rhTSH)

    International Nuclear Information System (INIS)

    Pacenza, N.A.; Groppo, N.; Guibourg, H.C.

    2013-01-01

    athological uptake in middle and lower cervical region right and left lower neck. He was reoperated on 4 months after his initial S: R esection of epithelial proliferation with thyroid aspect in superior mediastinum region . Pathology: N ode with extensive infiltration of neoplastic proliferation of follicular variant of papillary carcinoma with areas of connective tissue infiltrated periganglionar of papillary thyroid cancer . Lab 40 days after the second surgery: TSH 2.3 μIU/mL, FT4 0.82 ng/dL, Tg 4.7 ng/mL. Neck and chest CT showed neither pathological lesions nor lymphadenopathy. I 131 uptake with 7.4 MBq was: 1st hour: 8 % and 24 hours: 12 %. Neck Scan: M ultiple areas of tracer fixation in the neck . No pathological signs on neck palpation. Ablative dose of 7.4 GBq of I 131 was performed to the patient, previously using rhTSH (two doses of 0.9 mg), reaching TSH >100 μIU/mL. Scan post ablative dose: I mportant focus on right paratracheal region. Neck MRI showed: Absence of thyroid gland. Rounded image of about 10 mm at right paratracheal level. The patient initiates suppressive therapy with levothyroxine (LT4). Six months after ablation therapy (without LT4): TSH >100 μIU/mL, Tg: 13.8 ng/mL, TGA: 431 IU/mL. Body Scan with 2 mCi: P athological focus of radioiodine behind the right sternoclavicular joint. New neck MRI: Image in right pretracheal region smaller than the previous study . The patient received 5.55 GBq of I 131 . The same radioiodine treatment was repeated 8 months later. At present, 4 years after the patient's initial surgery, he is in good general health, performing his normal activities, with TGA in sharp decline, negative I 131 body scan and without signs of persistent or recurrent disease. Conclusions: We report a case of follicular variant papillary TC associated with GD with concomitant development of hyperthyroidism, with positive TGA, in a 22-year-old obese man. Highlights: 1) The importance of initial US exploration in a patient with GD, 2

  14. A real-time internal dose assessment exercise

    International Nuclear Information System (INIS)

    Bingham, D.; Bull, R. K.

    2013-01-01

    A real-time internal dose assessment exercise has been conducted in which participants were required to make decisions about sampling requirements, seek relevant information about the 'incident' and make various interim dose assessments. At the end of the exercise, each participant was requested to make a formal assessment, providing statements of the methods, models and assumptions used in that assessment. In this paper we describe how the hypothetical assessment case was set up and the exercise was conducted, the responses of the participants and the assessments of dose that they made. Finally we discuss the lessons learnt from the exercise and suggest how the exercise may be adapted to a wider range of participants. (authors)

  15. Nonparametric estimation of benchmark doses in environmental risk assessment

    Science.gov (United States)

    Piegorsch, Walter W.; Xiong, Hui; Bhattacharya, Rabi N.; Lin, Lizhen

    2013-01-01

    Summary An important statistical objective in environmental risk analysis is estimation of minimum exposure levels, called benchmark doses (BMDs), that induce a pre-specified benchmark response in a dose-response experiment. In such settings, representations of the risk are traditionally based on a parametric dose-response model. It is a well-known concern, however, that if the chosen parametric form is misspecified, inaccurate and possibly unsafe low-dose inferences can result. We apply a nonparametric approach for calculating benchmark doses, based on an isotonic regression method for dose-response estimation with quantal-response data (Bhattacharya and Kong, 2007). We determine the large-sample properties of the estimator, develop bootstrap-based confidence limits on the BMDs, and explore the confidence limits’ small-sample properties via a short simulation study. An example from cancer risk assessment illustrates the calculations. PMID:23914133

  16. Normalization of lymphocyte count after high ablative dose of I-131 in a patient with chronic lymphoid leukemia and secondary papillary carcinoma of the thyroid: case report

    International Nuclear Information System (INIS)

    Thom, Anneliese Rosmarie Gertrud Fischer; Hamerschlak, Nelson; Osawa, Akemi; Santos, Fabio Pires de Souza; Pasqualin, Denise da Cunha; Wagner, Jairo; Yamaga, Lilian Yuri Itaya; Cunha, Marcelo Livorsi da; Campos Neto, Guilherme de Carvalho; Funari, Marcelo Buarque de Gusmao; Teles, Veronica Goes

    2014-01-01

    The authors report the case of a 70-year-old male patient with chronic lymphoid leukemia who presented subsequently a papillary carcinoma of the thyroid with metastases to regional lymph nodes. The patient was treated with surgical thyroidectomy with regional and cervical lymph node excision and radioiodine therapy (I-131). The protocolar control scintigraphy 4 days after the radioactive dose showed I-131 uptake in both axillae and even in the inguinal regions. PET/CT showed faint FDG-F-18 uptake in one lymph node of the left axilla. An ultrasound guided fine needle biopsy of this lymph node identified by I-131 SPECT/CT and FDG-F-18 PET/CT revealed lymphoma cells and was negative for thyroid tissue and thyroglobulin content. The sequential blood counts done routinely after radiation treatment showed a marked fall until return to normal values of leucocytes and lymphocytes (absolute and relative), which were still normal in the last control 19 months after the radioiodine administration. Chest computed tomography showed a decrease in size of axillary and paraaortic lymph nodes. By immunohistochemistry, cells of the lymphoid B lineage decreased from 52% before radioiodine therapy to 5% after the procedure. The authors speculate about a possible sodium iodide symporter expression by the cells of this lymphoma, similar to some other non-thyroid tumors, such as breast cancer cells. (author)

  17. Effects of potassium iodide (KI) protective dose on the course of thyroid diseases diagnosed at the Outpatient Endocrinologic Clinic in Lodz, 1986, before Chernobyl accident

    International Nuclear Information System (INIS)

    Lewinski, A.; Wajs, E.; Sewerynek, E.

    1991-01-01

    2521 patients of the Lodz Outpatient Endocrinologic Clinic (2290 females, 231 males; inhabitants of the central region of Poland were included in the study. The obtained results indicate that: 1) KI administration neither increased the number of exacerbations of hyperthyroidism nor affected the onset of new cases of that disease in 1986. 2) The same can be said about the cases of thyroiditis and hypothyroidism. 3) No increase of ATMA or ATG antibodies ''prevalence, as well as no elevation of those antibodies'' titres after KI prophylactic dose were observed in the patients with Grave's disease and chronic thyroiditis, when compared to persons who did not take Lugol's iodine. 4) The course of the majority of diseases diagnosed in 1986, evaluated with use of the, so called, test for analysis of trends, became unchanged. 5) There were adverse side effects noted after KI in 32 patients out of all the examined 774 patients (i.e., in 4.13%); five of the affected patients required medical care. 6) After iodine tincture; side effects occurred in three patients in the group of 35 patients included in the examination, i.e., in 8.57%; none of the affected patients required medical care. 7) Our results, comprising the four year observation period after Chernobyl accident, do not indicate any increased incidence of malignant neoplasms of the thyroid gland, what confirms the apparent theoretical data; much longer observation time is necessary to reveal phenomena of scholastic type (10-15 years). (author). 30 refs, 11 figs, 14 tabs

  18. Our experience of high dose I-131 therapy in 75 patients with well differentiated carcinoma thyroid followed up over 5 years

    International Nuclear Information System (INIS)

    Dougall, P.; Kumar, A.; Ashok, P.; Chinwan, B.P.; Khan, B.; Pandey, D.; Joshi, N.D.

    2005-01-01

    Thyroid cancer is the most common endocrine malignancy. The epidemiology of thyroid cancer is variable, depending on the geographic location of the patient population. Well differentiated thyroid cancer (WTC), is responsive to high dose I-131 treatment, and is the most accepted form of therapy, even though the dose administered for ablation of residual thyroid tissue maybe controversial. At our centre, 75 patients of WTC, mean age 42.4 years, 22 males and 53 females (M:F 1:2.4), were treated with high dose oral I-131 therapy with a Total Mean Dose (TMD) of 263.6 mCi, 4 - 6 weeks post thyroidectomy. They were followed up over a period of 6 years. Twenty ( 26.7%) patients had follicular cancer (FC), 47 (62.7%) papillary cancer (PC) and 8 (10.7%) were mixed (MC), on histopathology, at presentation. 38 (50.7%) patients had only residual thyroid tissue (RTT) on I-131 whole body bone scan (WBS) and 37 (49.3%) presented with metastatic disease (MD) at the time of therapy. Of the 37 patients with MD, 21 (56.8%) had metastases to the lymph nodes, 6 (16.2%) to the lungs, 4 (10.8%) to bone, 3 (8.1%) to bone and lung, and 4 (10.8%) to lung plus lymph nodes. Twenty-three patients (7 FC , 13 - PC and 3 MC; 6 RTT, 17 - MD) , received more than one dose of I-131 with a TMD of 422.7 mCi (Range 88 1590 mCi ). 52 patients (13 FC, 34 PC, 5 MC; 20 MD and 32 RTT) received a single TMD of 104.4 (Range 39.5 219 mCi). On follow-up, 3 patients of FC with MD (2 lung metastasis and 1 with extensive lymph node metastasis), died within 3 months 2 years of therapy. 3 patients of MD (2 FC, 1-MC; 2 bone metastasis and 1 bone with lung metastasis) died after 5 .5 years, Of the 6 patients who died, 5 were FC and only 1 was MC. 2 patients with MD to lungs and bone had received a single dose and were lost to follow up. All patients with PC and FC with only RTT, were surviving at the end of 5 years. None of the patients with MD to lymph nodes died at the end of 5 years, either receiving single or

  19. Microdosimetry of 129I in the human thyroid

    International Nuclear Information System (INIS)

    Feige, Y.

    1977-01-01

    A microdosimetric evaluation of the dose distribution from I-129 in the human thyroid gland, taking into account the various physical, geometrical and physiological parameters suggested by the ICRP Pub. 23 (1975) will be presented, and compared to the dose distribution of other radioisotopes of iodine. Using Dillman's decay scheme data, (NM/MIRD No. 10, p. 73, 1975), and the methods applied by Feige et al. for the microdosimetry of I-125, it is found that the dose to the cell nucleus is about 60% of the 'average' calculated dose for the whole thyroid gland. This follows from the assumptions that typical thyroid follicles are 150 to 300μm in diameter, and that all the iodine is contained in the colloid fraction of the gland. Thus a significant part of the decay energy of I-129, which is due mainly to the beta particles whose average range in tissue is only about 30 μm, is deposited within the colloid itself, and fails to reach the cell nucleus, 3 μm away from the colloid/cell interface. Uncertainties and variations in the parameters of the thyroid model will also be discussed. When thyroid doses due to I-129 releases are assessed, by either the specific activity or the critical pathway models, the conservative environmental and biological assumptions usually made lead to a large margin of safety. If 'average' doses are used instead of the microdosimetric dose distribution an additional safety factor of about 2 is obtained

  20. Collection and use of individual behavioral and consumption rate data to improve reconstruction of thyroid doses from nuclear weapons tests in Kazakhstan

    International Nuclear Information System (INIS)

    Drozdovitch, Vladimir; Schonfeld, Sara; Bouville, Andre; Land, Charles; Luckyanov, Nick; Simon, Steven L.; Schwerin, Michael

    2008-01-01

    Full text: Historical behavioral and consumption rate data were collected from residents of Kazakhstan exposed to nuclear weapons testing fallout using a focus group data collection strategy. These data will enable improved thyroid dose estimation in a radiation epidemiological study being carried out the U.S. National Cancer Institute. The study on the relationship of radiation exposure from weapons testing fallout and thyroid disease in a cohort of 2,994 subjects is now in a stage of improving earlier dose estimates based on individual information collected from a basic questionnaire administered to the study population in 1998. The study subjects of both Kazakh and Russian origin were exposed during childhood to radioactive fallout from nuclear weapons tests conducted at the Semipalatinsk Nuclear Test Site between 1949 and 1962. Due to the long time since exposure, a well developed strategy is necessary to encourage accurate memory recall. Limitations of the data collected in 1998 suggested the need to obtain reliable information that is tailored specific to the requirements of the dose reconstruction algorithm and to the evaluation of individual dose uncertainties. Focus group data collection in Kazakhstan in 2007 involved four 8-person focus groups (three of women and one of men) in each of four exposed settlements where thyroid disease screening was conducted in 1998. Age-specific data on relevant childhood behaviour, including time spent indoors and consumption of milk and other dairy products from cows, goats, horses, and sheep, were collected from women's groups. Men's focus groups were interviewed about construction materials of houses and schools as well as animal grazing patterns and supplemental feed to animals. Information obtained from the focus groups are being used to derive the settlement-, ethnicity-, age-, and gender-specific (where appropriate) probability density distributions on individual consumption rates of milk and dairy products

  1. Thyroid dysfunction in pregnancy

    Directory of Open Access Journals (Sweden)

    El Baba KA

    2012-03-01

    Full Text Available Khalid A El Baba1, Sami T Azar21Department of Internal Medicine, Division of Endocrinology, Bahrain Specialist Hospital, Manama, Bahrain; 2Department of Internal Medicine, Division of Endocrinology, American University of Beirut-Medical Center, New York, NY, USAAbstract: Timely treatment of thyroid disease during pregnancy is important in preventing adverse maternal and fetal outcomes. Thyroid abnormalities are very often subclinical in nature and not easily recognized without specific screening programs. Even mild maternal thyroid hormone deficiency may lead to neurodevelopment complications in the fetus. The main diagnostic indicator of thyroid disease is the measurement of serum thyroid-stimulating hormone and free thyroxine levels. Availability of gestation-age-specific thyroid-stimulating hormone thresholds is an important aid in the accurate diagnosis and treatment of thyroid dysfunction. Pregnancy-specific free thyroxine thresholds not presently available are also required. Large-scale intervention trials are urgently needed to assess the efficacy of preconception or early pregnancy screening for thyroid disorders. Accurate interpretation of both antepartum and postpartum levels of thyroid hormones is important in preventing pregnancy-related complication secondary to thyroid dysfunction. This article sheds light on the best ways of management of thyroid dysfunction during pregnancy in order to prevent any possible maternal or fetal complication.Keywords: TSH, HCG, TBG

  2. Critical assessment of the test of 131I radioiodine uptake in the thyroid

    International Nuclear Information System (INIS)

    Nemec, J.; Roehling, S.; Vana, S.; Zamrazil, V.

    1979-01-01

    The value of radioiodine 131 I uptake by the thyroid gland was studied to differentiate the functional disorders of the thyroid gland by analysing a smaller group of patients using the classical method and the computer method for the evaluation of 2500 determinations. The conclusion may be drawn that the uptake of radioiodine was caused by a disturbance of the thyroid gland function only in a minority of cases whereas in the others it is dependent on the intake of iodine or of goitrogens. It is therefore not suitable as a screening method for the diagnosis of thyroid gland diseases. It is, however, useful for the differentation of various types of hyperthyroidism. (author)

  3. Iodine ingestion dose factors for the thyroid exposure of infants. Technical instructions 7. Jod-Ingestionsdosisfaktor fuer die Strahlenexposition der Schilddruese von Kleinkindern. Weisungsbeschluss 7

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    For calculations of the thyroid exposure of infants via the pasture-cow-milk pathway, the dose factor = 8.8 x 10/sup 5/ rem x m/sup 3/ / Ci x s should be used for elementary iodine during the vegetation period. For the components of other chemical-physical forms of /sup 131/I, the above value should be multiplied by the following factors: 1) For iodine aerosols, by the factor 0.1; 2) for organic iodine, by the factor 0.01. The mean vegetation period in the Federal Republic of Germany is 6 months.

  4. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk [Nuclear Environmental Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

  5. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    International Nuclear Information System (INIS)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk

    2016-01-01

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment

  6. Perspectives of development of thyroid cancers in Belarus

    International Nuclear Information System (INIS)

    Kenigsberg, J.; Buglova, E.; Paretzke, H.G.; Heidenreich, W.

    1996-01-01

    This paper gives an overview on the total number if thyroid cancers observed in Belarus after the Chernobyl accident among children, discusses possible sources of the observed increase over expected cases and compares these observations with predictive calculations using different risk coefficients published in the literature. To this purpose exposure estimates of the thyroid are made for children living in three selected areas. Different radioecological, dosimetric and other reasons make it very difficult to obtain reliable dose estimates for these victims, and the use of published risk coefficients for the assessment of future developments of the thyroid cancer incidence rates results in predictions which do not agree too well with the observations

  7. Chronic thyroiditis (Hashimoto disease)

    Science.gov (United States)

    Hashimoto thyroiditis; Chronic lymphocytic thyroiditis; Autoimmune thyroiditis; Chronic autoimmune thyroiditis; Lymphadenoid goiter - Hashimoto; Hypothyroidism - Hashimoto; Type 2 polyglandular autoimmune ...

  8. Interactive Rapid Dose Assessment Model (IRDAM): user's guide

    International Nuclear Information System (INIS)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This User's Guide provides instruction in the setup and operation of the equipment necessary to run IRDAM. Instructions are also given on how to load the magnetic disks and access the interactive part of the program. Two other companion volumes to this one provide additional information on IRDAM. Reactor Accident Assessment Methods (NUREG/CR-3012, Volume 2) describes the technical bases for IRDAM including methods, models and assumptions used in calculations. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios

  9. Dose assessment activities in the Republic of the Marshall Islands

    International Nuclear Information System (INIS)

    Simon, S.L.; Graham, J.C.

    1996-01-01

    Dose assessments, both retrospective and prospective, comprise one important function of a radiological study commissioned by the Republic of the Marshall Islands (RMI) government in late 1989. Estimating past or future exposure requires the synthesis of information from historical data, results from a recently completed field monitoring program, laboratory measurements, and some experimental studies. Most of the activities in the RMI to date have emphasized a pragmatic rather than theoretical approach. In particular, most of the recent effort has been expended on conducting an independent radiological monitoring program to determine the degree of deposition and the geographical extent of weapons test fallout over the nation. Contamination levels on 70% of the land mass of the Marshall Islands were unknown prior to 1994. The environmental radioactivity data play an integral role in both retrospective and prospective assessments. One recent use of dose assessment has been to interpret environmental measurements of radioactivity into annual doses that might be expected at every atoll. A second use for dose assessment has been to determine compliance with dose action level for the rehabitation of Rongelap Island. Careful examination of exposure pathways relevant to the island lifestyle has been necessary to accommodate these purposes. Finally, an examination is underway of gummed film, fixed-instrument, and aerial survey data accumulated during the 1950's by the Health and Safety Laboratory of the U.S. AEC. This article gives an overview of these many different activities and a summary of recent dose assessments

  10. Epidemiological methods for assessing dose-response and dose-effect relationships

    DEFF Research Database (Denmark)

    Kjellström, Tord; Grandjean, Philippe

    2007-01-01

    Selected Molecular Mechanisms of Metal Toxicity and Carcinogenicity General Considerations of Dose-Effect and Dose-Response Relationships Interactions in Metal Toxicology Epidemiological Methods for Assessing Dose-Response and Dose-Effect Relationships Essential Metals: Assessing Risks from Deficiency......Description Handbook of the Toxicology of Metals is the standard reference work for physicians, toxicologists and engineers in the field of environmental and occupational health. This new edition is a comprehensive review of the effects on biological systems from metallic elements...... access to a broad range of basic toxicological data and also gives a general introduction to the toxicology of metallic compounds. Audience Toxicologists, physicians, and engineers in the fields of environmental and occupational health as well as libraries in these disciplines. Will also be a useful...

  11. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  12. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  13. Re-assessment of dose from the Vinten extremity dosemeter

    International Nuclear Information System (INIS)

    O'Hagan, J.B.; Pearson, A.J.; Dutt, J.C.

    1989-01-01

    A procedure is described for re-assessing the dose from the Vinten extremity dosemeter using phototransferred thermoluminescence. The technique produces a linear response up to 50 Sv. The re-assessment efficiency is approximately 10% for the first re-assessment and 3-5% for the second re-assessment. The detection threshold values (at the 95% confidence level) are 3 mSv and 9 mSv respectively. (author)

  14. Assessment of concomitant testicular dose with radiochromic film

    International Nuclear Information System (INIS)

    Fricker, Katherine; Thompson, Christine; Meyer, Juergen

    2013-01-01

    To assess the suitability of EBT2 and XRQA2 Gafchromic film for measuring low doses in the periphery of treatment fields, and to measure the accumulative concomitant dose to the contralateral testis resulting from CT imaging, pre-treatment imaging (CBCT) and seminoma radiotherapy with and without gonadal shielding. Superficial peripheral dose measurements made using EBT2 Gafchromic film on the surface of water equivalent material were compared to measurements made with an ionisation chamber in a water phantom to evaluate the suitability and accuracy of the film dosimeter for such measurements. Similarly, XRQA2 was used to measure surface doses within a kilovoltage beam and compared with ionisation chamber measurements. Gafchromic film was used to measure CT, CBCT and seminoma treatment related testicular doses on an anthropomorphic phantom. Doses were assessed for two clinical plans, both with and without gonadal shielding. Testicular doses resulting from the treatment of up to 0.83 ± 0.17 Gy were measured per treatment. Additional doses of up to 0.49 ± 0.01 and 2.35 ± 0.05 cGy were measured per CBCT and CT image, respectively. Reductions in the testicular dose in the order of 10, 36 and 78 % were observed when gonadal shielding was fitted for treatment, CT and CBCT imaging, respectively. Gafchromic film was found to be suitable for measuring dose in the periphery of treatment fields. The dose to the testis should be limited to minimise the risk of radiation related side effects. This can be achieved by using appropriate gonadal shielding, irrespective of the treatment fields employed.

  15. Comparison of the measured radiation dose-rate by the ionization chamber and G (Geiger-Mueller) counter after radioactive lodine therapy in differentiated thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Hun [Dept. of Nuclear Medicine, Kyungbuk National University Hospital, Daegu (Korea, Republic of); Kim, Kgu Hwan [Dept. of Radiological Technology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    Radioactive iodine(131I) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

  16. Effect of developmental low dose PBDE 47 exposure on thyroid hormone status and serum concentrations of FSH and inhibin B in male rats

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, A.J.M.; Kuriyama, S.N.; Akkoc, Z.; Talsness, C.E.; Chahoud, I. [Charite Univ. Medical School Berlin (Germany). Inst. of Clinical Pharmacology and Toxicology, Dept. Toxicology, Campus Benjamin Franklin

    2004-09-15

    Several persistent halogenated organic compounds such as PCBs, dioxins and more recently, polybrominated diphenyl ethers (PBDEs) have been shown to disrupt thyroid hormone homeostasis in experimental animals. Particular concern exists regarding exposure to these compounds during critical periods of development when thyroid hormones orchestrate the growth and differentiation of many organs including the brain and the testis. While the contamination levels of PCBs and other persistent organic pollutants have declined in the past years, increasing levels of PBDEs have been detected in environmental and human samples including human breast milk. PBDEs are produced in large quantities and used worldwide as flame retardants in electrical appliances, carpets and furniture upholstery. Similar to other halogenated environmental organic pollutants, PBDEs seem to present a wide range of toxic effects including reproductive, endocrine, neurobehavioral and hepatic toxicity. Recently, it has been demonstrated that in utero and pubertal exposures to DE-71 (a commercial mixture containing mostly tetra- and penta-bromodiphenyl ethers) significantly reduce thyroxine levels (T4) in rats. The present study has focused on the possible effects of the tetra- BDE congener 2,2'4,4'-tetrabromo diphenyl ether (PBDE 47) on thyroid hormone status and associated changes on FSH and inhibin B levels in the developing male rat. We administered a single dose to gravid dams on gestation day 6 of either 140 {mu}g/kg BW or 700 {mu}g/kg BW PBDE 47. These doses are pertinent to human exposure situation because a study by She et al.3 found a mean level of 33.3 {mu}g PBDE 47 /kg fat in human breast adipose tissue with a range from 7.01 to 196 {mu}g PBDE 47 /kg fat.

  17. Mesorad dose assessment model. Volume 1. Technical basis

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; Bander, T.J.; Athey, G.F.; Ramsdell, J.V.

    1986-03-01

    MESORAD is a dose assessment model for emergency response applications. Using release data for as many as 50 radionuclides, the model calculates: (1) external doses resulting from exposure to radiation emitted by radionuclides contained in elevated or deposited material; (2) internal dose commitment resulting from inhalation; and (3) total whole-body doses. External doses from airborne material are calculated using semi-infinite and finite cloud approximations. At each stage in model execution, the appropriate approximation is selected after considering the cloud dimensions. Atmospheric processes are represented in MESORAD by a combination of Lagrangian puff and Gaussian plume dispersion models, a source depletion (deposition velocity) dry deposition model, and a wet deposition model using washout coefficients based on precipitation rates

  18. Thyroid gland disorder emergencies: thyroid storm and myxedema coma.

    Science.gov (United States)

    Hampton, Jessica

    2013-01-01

    Although thyroid dysfunction will develop in more than 12% of the US population during their lifetimes, true thyroid emergencies are rare. Thyroid storm and myxedema coma are endocrine emergencies resulting from thyroid hormone dysregulation, usually coupled with an acute illness as a precipitant. Careful assessment of risk and rapid action, once danger is identified, are essential for limiting morbidity and mortality related to thyroid storm and myxedema coma. This article reviews which patients are at risk, explains thyroid storm and myxedema coma, and describes pharmacological treatment and supportive cares.

  19. Total Thyroidectomy for Thyroid Cancer Followed by Thyroid Storm due to Thyrotropin Receptor Antibody Stimulation of Metastatic Thyroid Tissue

    DEFF Research Database (Denmark)

    Folkestad, Lars; Brandt, Frans; Brix, Thomas

    2017-01-01

    BACKGROUND: Graves disease (GD) is an autoimmune condition characterized by the presence of antibodies against the thyrotropin receptor (TRAB), which stimulate the thyroid gland to produce excess thyroid hormone. Theoretically, TRAB could stimulate highly differentiated thyroid cancer tissue and...... treatment continued until after the fourth RAI dose. Hypothyroidism did not occur until following the fifth RAI treatment. SUMMARY AND CONCLUSIONS: We present a patient initially diagnosed with thyrotoxicosis and subsequently with metastatic follicular variant of papillary thyroid cancer. It is suggested...... that TRAB stimulated the highly differentiated extrathyroidal metastatic thyroid tissue to produce excessive amounts of thyroid hormone, delayed diagnosis, and potential aggravation of the course of thyroid cancer....

  20. Assessment of exposure dose to workers in virtual decommissioning environments

    International Nuclear Information System (INIS)

    Jeong, KwanSeong; Moon, JeiKwon; Choi, ByungSeon; Hyun, Dongjun; Lee, Jonghwan; Kim, Ikjune; Kim, GeunHo; Seo, JaeSeok

    2014-01-01

    This paper is intended to suggest the method analyze and assess the exposure dose to workers in virtual decommissioning environments. To simulate a lot of decommissioning scenarios, decommissioning environments were designed in virtual reality. To simulate and assess the exposure dose to workers, human model also was designed in virtual environments. These virtual decommissioning environments made it possible to real-time simulate and assess the exposure dose to workers. This work was to be able to simulate scenarios of decommissioning so that exposure dose to workers could be measured and assessed. To establish the plan of exposure dose to workers during decommissioning of nuclear facilities before decommissioning activities are accomplished, the method of simulation assessment was developed in virtual radiological environments. But this work was developed as a tool of simulation for single subject mode. Afterwards, the simulation environment for multi-subjects mode will be upgraded by simultaneous modules with networking environments. Then the much more practical method will be developed by changing number of workers and duration of time under any circumstances of decommissioning

  1. Assessment of exposure dose to workers in virtual decommissioning environments

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, KwanSeong; Moon, JeiKwon; Choi, ByungSeon; Hyun, Dongjun; Lee, Jonghwan; Kim, Ikjune; Kim, GeunHo; Seo, JaeSeok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    This paper is intended to suggest the method analyze and assess the exposure dose to workers in virtual decommissioning environments. To simulate a lot of decommissioning scenarios, decommissioning environments were designed in virtual reality. To simulate and assess the exposure dose to workers, human model also was designed in virtual environments. These virtual decommissioning environments made it possible to real-time simulate and assess the exposure dose to workers. This work was to be able to simulate scenarios of decommissioning so that exposure dose to workers could be measured and assessed. To establish the plan of exposure dose to workers during decommissioning of nuclear facilities before decommissioning activities are accomplished, the method of simulation assessment was developed in virtual radiological environments. But this work was developed as a tool of simulation for single subject mode. Afterwards, the simulation environment for multi-subjects mode will be upgraded by simultaneous modules with networking environments. Then the much more practical method will be developed by changing number of workers and duration of time under any circumstances of decommissioning.

  2. The assessment of personal dose due to external radiation

    International Nuclear Information System (INIS)

    Boas, J.F.; Young, J.G.

    1990-01-01

    The fundamental basis of thermoluminescent dosimetry (TLD) is discussed and a number of considerations in the measurement of thermoluminescence described, with particular reference to CaSO 4 :Dy. The steps taken to convert a thermoluminescence measurement to an exposure and then an absorbed dose are outlined. The calculation of effective dose equivalents due to external exposure to γ-radiation in a number of situations commonly encountered in a uranium mine is discussed. Factors which may affect the accuracy of external dose assessments are described

  3. RET/PTC and PAX8/PPARγ chromosomal rearrangements in post-Chernobyl thyroid cancer and their association with I-131 radiation dose and other characteristics

    Science.gov (United States)

    Leeman-Neill, Rebecca J.; Brenner, Alina V.; Little, Mark P.; Bogdanova, Tetiana I.; Hatch, Maureen; Zurnadzy, Liudmyla Y.; Mabuchi, Kiyohiko; Tronko, Mykola D.; Nikiforov, Yuri E.

    2012-01-01

    Background Childhood exposure to I-131 from the 1986 Chernobyl accident led to a sharp increase in papillary thyroid carcinoma (PTC) incidence in regions surrounding the reactor. Data concerning the association between genetic mutations in PTCs and individual radiation doses are limited. Methods We performed mutational analysis of 62 PTCs diagnosed in a Ukrainian cohort of patients who were Chernobyl tumors and show different associations for point mutations and chromosomal rearrangements with I-131 dose and other factors. These data support the relationship between chromosomal rearrangements, but not point mutations, and I-131 exposure and point to a possible role of iodine deficiency in generation of RET/PTC rearrangements in these patients. PMID:23436219

  4. External dose assessment in the Ukraine following the Chernobyl accident

    Science.gov (United States)

    Frazier, Remi Jordan Lesartre

    While the physiological effects of radiation exposure have been well characterized in general, it remains unclear what the relationship is between large-scale radiological events and psychosocial behavior outcomes in individuals or populations. To investigate this, the National Science Foundation funded a research project in 2008 at the University of Colorado in collaboration with Colorado State University to expand the knowledge of complex interactions between radiation exposure, perception of risk, and psychosocial behavior outcomes by modeling outcomes for a representative sample of the population of the Ukraine which had been exposed to radiocontaminant materials released by the reactor accident at Chernobyl on 26 April 1986. In service of this project, a methodology (based substantially on previously published models specific to the Chernobyl disaster and the Ukrainian population) was developed for daily cumulative effective external dose and dose rate assessment for individuals in the Ukraine for as a result of the Chernobyl disaster. A software platform was designed and produced to estimate effective external dose and dose rate for individuals based on their age, occupation, and location of residence on each day between 26 April 1986 and 31 December 2009. A methodology was developed to transform published 137Cs soil deposition contour maps from the Comprehensive Atlas of Caesium Deposition on Europe after the Chernobyl Accident into a geospatial database to access these data as a radiological source term. Cumulative effective external dose and dose rate were computed for each individual in a 703-member cohort of Ukrainians randomly selected to be representative of the population of the country as a whole. Error was estimated for the resulting individual dose and dose rate values with Monte Carlo simulations. Distributions of input parameters for the dose assessment methodology were compared to computed dose and dose rate estimates to determine which

  5. Thyroid dysfunction after mantle irradiation of Hodgkin`s disease patients

    Energy Technology Data Exchange (ETDEWEB)

    Khoo, V.S.; Liew, K.H.; Crennan, E.C.; D`Costa, I.M. [Peter MacCallum Caner Institute, East Melbourne, VIC (Australia). Department of Radiation Oncology; Quong, G. [Austin and Repatriation Medical Centre, West Heidelberg, VIC (Australia). Department of Radiation Oncology

    1998-02-01

    Thyroid dysfunction can develop in patients with Hodgkin`s disease who are treated with mantle irradiation. During the period 1970-89, the records of 320 patients who received mantle irradiation and who had thyroid function tests (TFT) were retrospectively reviewed. The median age was 30 years (range, 7-69 years). The median mantle and thyroid dose was 36 Gy (range, 30-40 Gy) and 39.8 Gy (range, 32-65 Gy), respectively. Overall thyroid dysfunction was present in 39% of the patients. Clinical hypothyroidism was seen in 10% and biochemical hypothyroidism was noted in 25%. Hyperthyroidism was found in 4% of patients. Thyroid nodules had developed in six patients (2%), of which those in four patients were malignant. Age, sex, histological subtype, stage of disease, dose, Iymphangiogram and treatment with chemotherapy were not significant factors in the development of thyroid dysfunction. The narrow dose range prevented adequate analysis of dose effect. The results indicate that the incidence of thyroid abnormalities is high enough to warrant regular TFT assessment with pre-irradiation levels and follow-up testing for life because the development of abnormalities can occur many years later. Thyroid examination should form part of the routine follow-up examination and any abnormality should be promptly investigated. Copyright (1998) Blackwell Science Pty Ltd 32 refs., 3 tabs.

  6. The risk factor of thyroid

    International Nuclear Information System (INIS)

    Kusama, Tomoko

    1979-01-01

    For the purposes of radiation protection, the noteworthy risk of thyroid is carcinogenesis. The risk factor which ICRP presented in the publication-26 is 5 x 10 - 6 rem - 1 . This numerical value is based upon the estimated likelihood of inducing fatal thyroid cancer. On the other hand, the risk factor presented by the BEIR report is 4 x 10 - 6 yr - 1 . This value was decided after consideration of the risks of both fatal and non-fatal cancer of thyroid. The following features distinguished thyroid cancer from malignancy of other tissue from medical point of view. 1) A large difference between incidence and mortality in case of thyroid cancer is recognized, because the thyroid cancer could be successfully treated by surgical or radiological treatment. 2) The high prevalence of clinically silent tumor in thyroid gland has been reported. The incidence of thyroid cancer, therefore, is very dependent on methods of medical inspection. The prevalence of radiation induced thyroid cancer is modified by various factors such as age, sex, latency, dose and dose rate. The latent period is very important factors such as ave, sex, latency, dose and dose rate. The latent period is a very important factor in the estimation of accumulated total risk of thyroid malignancy. What is included in the risk caused by thyroid irradiation must be investigated. The risk of non-fatal cancer should be considered in the same way as that of fatal cancer. The dose-equivalent limit of thyroid in non-uniform irradiation caused by radioactive iodine is decided by the limit for non-stochastic effects. Therefore the further consideration of non-stochastic effects of thyroid is necessary. (author)

  7. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    International Nuclear Information System (INIS)

    Oliveira, Jetro Pereira de; Batista, Delano Valdivino Santos; Bardella, Lucia Helena; Carvalho, Arnaldo Rangel

    2009-01-01

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  8. The absorbed dose to the blood is a better predictor of ablation success than the administered {sup 131}I activity in thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A.; Lassmann, Michael; Reiners, Christoph; Haenscheid, Heribert [University of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Maeder, Uwe [University of Wuerzburg, Comprehensive Cancer Center Mainfranken, Wuerzburg (Germany); Luster, Markus [University of Ulm, Department of Nuclear Medicine, Ulm (Germany)

    2011-04-15

    The residence time of {sup 131}I in the blood is likely to be a measure of the amount of {sup 131}I that is available for uptake by thyroid remnant tissue and thus the radiation absorbed dose to the target tissue in {sup 131}I ablation of patients with differentiated thyroid cancer (DTC). This hypothesis was tested in an investigation on the dependence of the success rate of radioiodine remnant ablation on the radiation absorbed dose to the blood (BD) as a surrogate for the amount of {sup 131}I available for iodine-avid tissue uptake. This retrospective study included 449 DTC patients who received post-operative {sup 131}I ablation in our centre in the period from 1993 to 2007 and who returned to us for diagnostic whole-body scintigraphy. The BD was calculated based on external dose rate measurements using gamma probes positioned in the ceiling. Success of ablation was defined as a negative diagnostic {sup 131}I whole-body scan and undetectable thyroglobulin levels at 6 months follow-up. Ablation was successful in 56.6% of the patients. The rate of successful ablation correlated significantly with BD but not with the administered activity. Patients with blood doses exceeding 350 mGy (n = 144) had a significantly higher probability for successful ablation (63.9%) than the others (n = 305, ablation rate 53.1%, p = 0.03). In contrast, no significant dependence of the ablation rate on the administered activity was observed. The BD is a more powerful predictor of ablation success than the administered activity. (orig.)

  9. Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

    International Nuclear Information System (INIS)

    Maldonado, Delis

    2012-01-01

    The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes

  10. Induction of thyroid carcinoma by ionizing radiation

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1987-01-01

    The risk of thyroid carcinoma induction, due to external or internal exposure of the thyroid, is described and quantified. A modified absolute risk model is used. The assessment is based on a risk coefficient of 2.5 induced cases per million persons per cGy per year of risk, derived from US-investigations in persons who had received external radiation therapy during childhood for treatment of benign diseases. This value is considered to be suitable for a dose range of 0.06-15 Gy. Modifying factors are given for age at exposure, gender and relative effectiveness of various radiation sources. The minimum induction period is taken to be 5 years; the remaining life expectancy minus minimum induction period is considered as the number of years at risk. For external exposure of the general public, a calculated incidence for lethal thyroid carcinoma of 7.5 cases per million persons per cGy thyroid dose for the total life time may be derived from the average life expectancy, the age distribution of the population and a mortality of radiation induced thyroid carcinoma of 10%. This figure is in good agreement with earlier estimates. (orig./ECB) [de

  11. Development of a real-time radiological dose assessment system

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Lee, Young Bok; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae; Choi, Young Gil

    1997-07-01

    A radiological dose assessment system named FADAS has been developed. This system is necessary to estimated the radiological consequences against a nuclear accident. Mass-consistent wind field module was adopted for the generation of wind field over the whole domain using the several measured wind data. Random-walk dispersion module is used for the calculation of the distribution of radionuclides in the atmosphere. And volume-equivalent numerical integration method has been developed for the assessment of external gamma exposure given from a randomly distributed radioactive materials and a dose data library has been made for rapid calculation. Field tracer experiments have been carried out for the purpose of analyzing the site-specific meteorological characteristics and increasing the accuracy of wind field generation and atmospheric dispersion module of FADAS. At first, field tracer experiment was carried out over flat terrain covered with rice fields using the gas samplers which were designed and manufactured by the staffs of KAERI. The sampled gas was analyzed using gas chromatograph. SODAR and airsonde were used to measure the upper wind. Korean emergency preparedness system CARE was integrated at Kori 4 nuclear power plants in 1995. One of the main functions of CARE is to estimate the radiological dose. The developed real-time dose assessment system FADAS was adopted in CARE as a tool for the radiological dose assessment. (author). 79 refs., 52 tabs., 94 figs.

  12. Skin dose assessment in routine personnel beta/gamma dosimetry

    International Nuclear Information System (INIS)

    Christensen, P.

    1980-01-01

    The International Commission on Radiological Protection (Publication 26) has recommended a tissue depth of 5 to 10 mg.cm -2 for skin dose assessments. This requirement is generally not fulfilled by routine monitoring procedures because of practical difficulties in using very thin dosemeters with low sensitivity and therefore a high minimum detectable dose. Especially for low-energy beta-ray exposures underestimations of the skin dose by a factor of more than ten may occur. Low-transparent graphite-mixed sintered LiF and Li 2 B 4 0 7 : Mn dosemeters were produced which show a skin-equivalent response to beta and gamma exposures over a wide range of energies. These have found wide-spread application for extremity dosimetry but have not yet been generally introduced in routine personnel beta/gamma monitoring. The following adaptations of existing routine monitoring systems for improved skin dose assessments have been investigated: 1) Placement of a supplementary, thin, skin-dose equivalent dosemeter in the TLD badge to give additional information on low-energy exposures. 2) Introduction of a second photomultiplier in the read-out chamber which enables a simultaneous determination of emitted TL from both sides of the dosemeter separately. This method makes use of the selfshielding of the dosemeter to give information on the low-energy dose contribution. 3) By diffusion of Li 2 B 4 0 7 into solid LiF-dosemeters it was possible to produce a surface layer with a new distinct glow-peak at about 340 deg C which is not present in the undiffused part of the LiF chip, and which can be utilized for the assessment of the skin-dose. Data on energy response and accuracy of dose measurement for beta/gamma exposures are given for the three methods and advantages and disadvantages are discussed (H.K.)

  13. Public Dose Assessment Modeling from Skyshine by Proton Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Mwambinga, S. A. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Yoo, S. J. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    In this paper, the skyshine dose by proton accelerator (230 MeV) has been evaluated. The amount of dose by skyshine is related to some influence factors which are emission angle (Height wall), the thickness of ceiling and distance from source to receptor (Human body). Empirical formula is made by using MCNPX code results. It can easily calculate and assess dose from skyshine by proton accelerator. The skyshine doses are calculated with MCNPX code and DCFs in ICRP 116. Thereafter, we made empirical formula which can calculate dose easily and be compared with the results of MCNPX. The maximum exposure point by skyshine is about 5 ∼ 10 m from source. Therefore, the licensee who wants to operate the proton accelerator must keep the appropriate distance from accelerator and set the fence to restrict the approach by the public. And, exposure doses by accelerator depend on operating time and proton beam intensities. Eq. (6) suggested in this study is just considered for mono energy proton accelerator. Therefore, it is necessary to expand the dose calculation to diverse proton energies. Radiations like neutron and photon generated by high energy proton accelerators over 10 MeV, are important exposure sources to be monitored to radiation workers and the public members near the facility. At that case, one of the exposure pathways to the public who are located in near the facility is skyshine. Neutrons and photons can be scattered by the atmosphere near the facility and exposed to public as scattered dose. All of the facilities using high energy radiation and NDI (Non-Destructive Inspection) which is tested at open field, skyshine dose must be taken into consideration. Skyshine dose is not related to the wall thickness of radiation shielding directly.

  14. Sensitive TSH assay in the assessment of thyroid function and its value in the follow-up of hyperthyroidism treated with radioiodine

    International Nuclear Information System (INIS)

    Masjhur, J.S.; Ilyas, R.A.M.

    1989-01-01

    This paper confirms the value of ''sensitive'' TSH assay in thyroid function assessment of untreated subjects and those who have undergone radioiodine treatment for hyperthyroidism from 120 patients. (ELC). 3 tabs.; 1 fig.; 7 refs

  15. Assessment of thyroid function in patients with laryngeal carcinoma treated surgically and with radiotherapy

    International Nuclear Information System (INIS)

    Skoneczny, J.; Kulczynski, B.; Sowinski, J.

    1975-01-01

    In 40 patients with laryngeal carcinoma after total laryngectomy and radiotherapy the triiodotyronine binding index, total thyroxine level, serum free thyroxine index were determined before, during and after treatment. At the same time thyroid iodine uptake was determined by the routine method. Surgical treatment as well as radiotherapy caused lowering of thyroid functions. These changes had a high tendency for return to normal values, not earlier, however, than 6 months after treatment. The authors stress that endocrine thyroid disturbances may have an important influence on delay of psychic rehabilitation and speech training in laryngectomized patients. (author)

  16. Radiological dose assessment from the operation of Daeduk nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Won Tae; Kim, Eun Han; Suh, Kyung Suk; Choi, Young Gil [Korea Atomic Energy Research Institute, Taejon (Korea)

    2000-02-01

    The objective of this project is to assure the public acceptance for nuclear facilities, and the environmental safety from the operation of Daeduk nuclear facilities, such as HANARO research reactor, nuclear fuel processing facilities and others. For identifying the integrity of their facilities, the maximum individual doses at the site boundary and on the areas with high population density were assessed. Also, the collective doses within radius 80 km from the site were assessed. The radiation impacts for residents around the site from the operation of Daeduk nuclear facilities in 1999 were neglectable. 8 refs., 10 figs., 27 tabs. (Author)

  17. Assessment of dose received by organ in lumbosacral examination

    International Nuclear Information System (INIS)

    Eltyeib, Nashwa Kheirallah

    2014-11-01

    The biological damage produced by radiation is closely related to the amount of energy absorbed in the case x- rays. Measurement of produced ionizing provides a useful assessment of the total energy absorbed. This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study was performed to assess the effective dose (ED) received in lumbosacral radiography examination and to analyze effective dose distributions among radiological department under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 50 patients. The following parameters were recorded: age weight, height, body mass index (BMI) derived from mass (kg) and (height. (m)) and exposure factors. The dose was measured for lumbosacral x- rays examination. For effective dose calculation, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for lumbosacral spine A P and lateral examinations. The ED values were then calculated from the obtained ESD values using IAEA calculation methods. Effective doses were than calculated from energy imported using ED conversion factors by IAEA. The results of ED values calculated showed that patient exposures were within the normal range of exposure. The mean ED values calculated were (2.49 ±0.03) mGy and (5.5.60 ± 0.0.22) mGy for Lumbosacral spine A P and lateral examinations, respectively. Further studies are recommended with more number of patients and using more modalities for comparison.(Author)

  18. Influence of dose, age at the onset of disease and ultrasonographic findings of the thyroid gland on the early outcome of the radioiodine treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Ugrinska, A.; Pop Gjorceva, D.; Muratovska, L.; Crcareva, B.; Stojanovski, S.

    2007-01-01

    Full text: Aim of the study: Estimation of the early effects of the treatment of hyperthyroidism with radioactive iodine in correlation with the radioiodine dose, the age at the onset of disease and ultrasonographic (US) findings of the thyroid. Material and methods: Retrospective analysis of the files of 80 patients that underwent a radioactive iodine treatment from the period of 1987 till 2006 because of a diffuse hyperthyroid goiter was performed. The patients were divided in two groups. Group C consisted of patients who were treated with calculated doses from 60-100μC/ml gland volume and group NC who received higher, non-calculated doses. According to age at the onset of disease patients were divided in two groups- group A younger than 40 years and group B older than 40 years. According to the US findings of the thyroid prior to radioiodine therapy patients were divided in two groups group N with predominantly normal US findings and group H with predominantly hypoechoic structure. Results: One year after the application of radioactive iodine 58% of the patients from the group C still remained hyperthyroid, 29% became euthyroid and only 13% developed early hypothyroidism. In the NC group only 7% remained hyperthyroid, 40% were euthyroid, while 54% of the patients developed early hypothyroidism. The occurrence of early hypothyroidism was significantly more frequent in NC than in C group (58% vs. 32%, p<0.05). The age was predictor for the probability of development of early hypothyroidism in C group: only 13% younger in group A, but 46% older patients from group B developed an early hypothyroidism. In the NC group the age was not a predictive factor. In 44 patients there were available records on the US findings prior to radioiodine therapy. In the N group patients that received calculated dose of radioiodine therapy remained euthyroid in 86%, while the patients that received non-calculated dose achieved euthyroidism only in 30%.In the H group there was no

  19. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  20. Assessment of risks associated to ionizing radiations: lung cancers after domestic radon exposure and thyroid cancers after accidental exposure to radioactive iodines

    International Nuclear Information System (INIS)

    Catelinois, O.

    2004-09-01

    The aim of this work is to develop a critical analysis of quantitative risk assessment in the field of ionizing radiation and to provide new estimates of attributable risks for particular situations of environmental exposure to ionizing radiation. This work is based on knowledge about dose-response relationships and ionizing radiation exposure of the general population. The work focuses on two different situations that both present an important interest for public health: lung cancer associated with domestic radon exposures (natural situation) and thyroid cancer associated with the Chernobyl accident fallout (accidental situation). The assessment of lung cancer risk associated with domestic radon exposure considers 10 dose-response relationships resulting from miner cohorts and case-control studies in the general population. A critical review of available data on smoking habits has been performed and allowed to consider the interactions between radon and tobacco. The exposure data come from measurements campaigns carried out since the beginning of the 1980 by the Institute for Radiation protection and Nuclear Safety and the Health General Directory in France. The French lung cancer mortality data are provided by the I.N.S.E.R.M.. Estimates of the number of attributable cancers are carried out for the whole country, stratified by 8 large regions (Z.E.A.T.) and by 96 departments for the year 1999 allowing to perform a sensibility analysis according to the geographical level of calculation. Uncertainties associated to risk coefficients and exposures have been quantified and it's impact on risk estimates is calculated. The estimated number of deaths attributable to domestic radon exposure ranges from 543 (90% uncertainty interval (U.I.): 75-1,097) to 3,108 (90% U.I.: 2,996-3,221). The corresponding risk fractions range from 2.2% (90% U.I.: 0.3%-4.4%) to 12.4% (90% U.I.: 11.9%-12.8%). The assessment of thyroid cancer risk in the most exposed area of France due to the

  1. Biochemical assessments of thyroid profile, serum 25-hydroxycholecalciferol and cluster of differentiation 5 expression levels among children with autism

    Directory of Open Access Journals (Sweden)

    Desoky T

    2017-09-01

    Full Text Available Tarek Desoky,1 Mohammed H Hassan,2 Hanan M Fayed,3 Hala M Sakhr4 1Department of Neuropsychiatry, 2Department of Medical Biochemistry and Molecular Biology, 3Department of Clinical and Chemical Pathology, 4Department of Pediatrics, Qena Faculty of Medicine, Qena University Hospitals, South Valley University, Qena, Egypt Background: The exact pathogenesis of autism is still unknown. Both thyroid hormones and 25(OHD are important for brain development, in addition to CD5; all have immunomodulatory actions by which their dysregulation may have a potential role in autism pathogenesis.Objectives: The objectives of this study were to assess the thyroid profile, serum 25(OHD levels and CD5 expression levels among autistic patients and to find out the correlations between the measured biomarkers with each other on one side and with the disease severity on the other side.Patients and methods: This cross-sectional case–control study has been conducted on 60 children with autism and 40 controls, recruited from Qena Governorate, Upper Egypt. Childhood Autism Rating Scale (CARS score was used to assess the included patients. Biochemical assays of thyroid function in the form of free triiodothyronine (FT3, free tetraiodothyronine (FT4, thyroid-stimulating hormone (TSH and 25(OHD were done using commercially available enzyme-linked immunosorbent assay (ELISA kits, while CD5 expression levels were measured using flow cytometry (FCM analysis for all the included patients and controls.Results: The overall measurement results show significant higher mean serum TSH levels, mean CD5 expression levels with significant lower mean serum 25(OHD levels among autistic children when compared with the control group (p<0.05 for all. Significant negative correlations between CD5 with FT3, FT4 and 25(OHD were observed. CARS score showed significant negative correlations with both FT3 and 25(OHD, while it was positively correlated with CD5 in a significant manner (p<0.05 for

  2. Global skeletal uptake of technetium-99m methylene diphosphonate in female patients receiving suppressive doses of L-thyroxine for differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Frusciante, V.; Dicembrino, F. [Department of Nuclear Medicine, Ospedale ``Casa Sollievo della Sofferenza``, IRCCS di San Giovanni Rotondo (Italy); Carnevale, V. [Division of Internal Medicine, Ospedale ``Casa Sollievo della Sofferenza``, IRCCS di San Giovanni Rotondo (Italy); Scillitani, A.; Zingrillo, M.; Ghiggi, M.R. [Division of Endocrinology, Ospedale ``Casa Sollievo della Sofferenza``, IRCCS di San Giovanni Rotondo (Italy); Giannatempo, G.M. [Department of Radiology, Ospedale ``Casa Sollievo della Sofferenza``, IRCCS di San Giovanni Rotondo (Italy); Minisola, S. [Istituto di II Clinica Medica, Universita degli Studi di Roma ``La Sapienza``, Rome (Italy)

    1998-02-01

    This study was carried out in order to investigate the possible detrimental effects on bone of levothyroxine (l-T{sub 4}) suppressive therapy in female patients who had undergone surgery for differentiated thyroid cancer (DTC). Twenty female (14 premenopausal and 6 postmenopausal) patients receiving l-T{sub 4} suppressive therapy for DTC were studied. The sample was selected in such a way as to avoid factors influencing bone metabolism other than l-T{sub 4}. All patients were monitored by sensitive thyroid-stimulating hormone, free triiodothyronine and free thyroxine assays throughout the follow-up. Nineteen healthy (12 premenopausal and 7 postmenopausal) matched women served as controls. In all subjects bone turnover was evaluated by the measurement of global skeletal uptake of technetium-99m methylene diphosphonate (GSU); bone mineral density (BMD) was measured by quantitative computed tomography at the lumbar spine (LS) and by dual-energy X-ray absorptiometry both at the LS and at three femoral sites: the femoral neck, Ward`s triangle and the greater trochanter. No significant difference was found in either GSU or BMD between patients (treated for an average period of 68 months) and controls in the whole sample or in any subgroup. Furthermore, no correlations were found between either GSU or BMD and the duration of therapy, daily doses of l-T{sub 4} or results of thyroid function tests. Our data show that carefully monitored l-T{sub 4} therapy does not influence skeletal turnover (directly reflected by GSU) or the bone density of the spine and femur. (orig.) With 1 fig., 2 tabs., 36 refs.

  3. Global skeletal uptake of technetium-99m methylene diphosphonate in female patients receiving suppressive doses of L-thyroxine for differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Frusciante, V.; Dicembrino, F.; Carnevale, V.; Scillitani, A.; Zingrillo, M.; Ghiggi, M.R.; Giannatempo, G.M.; Minisola, S.

    1998-01-01

    This study was carried out in order to investigate the possible detrimental effects on bone of levothyroxine (l-T 4 ) suppressive therapy in female patients who had undergone surgery for differentiated thyroid cancer (DTC). Twenty female (14 premenopausal and 6 postmenopausal) patients receiving l-T 4 suppressive therapy for DTC were studied. The sample was selected in such a way as to avoid factors influencing bone metabolism other than l-T 4 . All patients were monitored by sensitive thyroid-stimulating hormone, free triiodothyronine and free thyroxine assays throughout the follow-up. Nineteen healthy (12 premenopausal and 7 postmenopausal) matched women served as controls. In all subjects bone turnover was evaluated by the measurement of global skeletal uptake of technetium-99m methylene diphosphonate (GSU); bone mineral density (BMD) was measured by quantitative computed tomography at the lumbar spine (LS) and by dual-energy X-ray absorptiometry both at the LS and at three femoral sites: the femoral neck, Ward's triangle and the greater trochanter. No significant difference was found in either GSU or BMD between patients (treated for an average period of 68 months) and controls in the whole sample or in any subgroup. Furthermore, no correlations were found between either GSU or BMD and the duration of therapy, daily doses of l-T 4 or results of thyroid function tests. Our data show that carefully monitored l-T 4 therapy does not influence skeletal turnover (directly reflected by GSU) or the bone density of the spine and femur. (orig.)

  4. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  5. Monte Carlo determination of dose in crystalline and thyroid during chest tomography examinations; Determinacion Monte Carlo de dosis en cristalino y tiroides durante examenes de tomografia de torax

    Energy Technology Data Exchange (ETDEWEB)

    Quispe H, B.; Pena V, J. D.; Waldo B, G.; Leon M, M.; Ceron R, P.; Vallejo H, A.; Sosa A, M. [Universidad de Guanajuato, Campus Leon, Division de Ciencias e Ingenierias, Loma del Bosque 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Vega C, H. R., E-mail: b.quispehuillcara@ugto.mx [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas, Zac. (Mexico)

    2017-10-15

    Computed tomography is a diagnostic imaging method that deposits higher doses than other radio diagnosis methods. The knowledge of the spectrum of X-rays is important, since is in direct function with the dose absorbed by the patient. In this work we estimated the spectrum of X-rays, produced during the interaction of monoenergetic electrons of 130 KeV with Tungsten white, in order to determine their energetic characteristics at 50 cm from the focal point. The study was done using Monte Carlo methods with the code MCNP5 where the X-ray tube of a Siemens SOMATOM Perspective tomograph of the General Regional Hospital of Leon, Mexico was modeled. In the calculations, 3 x 10{sup 8} stories were used and a relative uncertainty of less than 0.1% was obtained. Also, a neck manikin with thyroid, thorax and head that included the eye, the table and gantry with 70 cm opening of the tomography was modeled. The X-ray spectrum calculated with a cut thickness of 10 mm limited by Pb collimators was used as the source term. The radiological service routine scanning protocol was used for chest computed tomography; the step-by-step or instant trigger method was simulated by moving the manikin coordinates for each cut and 360 degree continuous rotation movement. 36 positions of the X-ray tube were used in steps of 10 degrees. The radiation dispersed in the thorax deposits a dose of 2.063 mGy in crystalline and 252 mGy in thyroid. (Author)

  6. The assessment of the carcinogenic effects of low dose radiation

    International Nuclear Information System (INIS)

    Tubiana, M.; Lafuma, J.; Masse, R.; Latarjet, R.

    1991-01-01

    It is concluded that the exclusion of patients for the purposes of risk estimation, the choice of a particular relative risk projection model and of a dose reduction factor equal to 2 are all decisions which result in an overestimation of the actual risk. These choices can be understood when the aim is radiation protection and when it is safer to overestimate the risk; however, they are open to criticism if the aim is a realistic assessment of the risk. For low doses, below 50 mSv/year, and when all causes of uncertainty are added, the actual risk might be markedly lower than the risk estimated with the ICRP (1991) carcinogenic risk coefficient and the DRF estimated by ICRP. Future studies should aim at providing direct and more precise assessments of risk coefficients in the low dose region. (Author)

  7. Use of TSHβ:EGFP transgenic zebrafish as a rapid in vivo model for assessing thyroid-disrupting chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Cheng [Key Laboratory of Aquatic Biodiversity and Conservation of Chinese Academy of Sciences, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, Hubei (China); Graduate University of Chinese Academy of Sciences, Beijing (China); Jin, Xia; He, Jiangyan [Key Laboratory of Aquatic Biodiversity and Conservation of Chinese Academy of Sciences, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, Hubei (China); Yin, Zhan, E-mail: zyin@ihb.ac.cn [Key Laboratory of Aquatic Biodiversity and Conservation of Chinese Academy of Sciences, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, Hubei (China)

    2012-07-15

    Accumulating evidence indicates that a wide range of chemicals have the ability to interfere with the hypothalamic–pituitary–thyroid (HPT) axis. Novel endpoints should be evaluated in addition to existing methods in order to effectively assess the effects of these chemicals on the HPT axis. Thyroid-stimulating hormone subunit β (TSHβ) plays central regulatory roles in the HPT system. We identified the regulatory region that determines the expression level of zebrafish TSHβ in the anterior pituitary. In the transgenic zebrafish with EGFP driven by the TSHβ promoter, the similar responsive patterns between the expression levels of TSHβ:EGFP and endogenous TSHβ mRNA in the pituitary are observed following treatments with goitrogen chemicals and exogenous thyroid hormones (THs). These results suggest that the TSHβ:EGFP transgenic reporter zebrafish may be a useful alternative in vivo model for the assessment of chemicals interfering with the HPT system. Highlights: ► The promoter of zebrafish TSHβ gene has been identified. ► The stable TSHβ:EGFP transgenic zebrafish reporter germline has been generated. ► The EGFP in the transgenic fish recapitulated the pattern of pituitary TSHβ mRNA. ► The transgenic zebrafish may be an in vivo model for EDC assessment.

  8. Use of TSHβ:EGFP transgenic zebrafish as a rapid in vivo model for assessing thyroid-disrupting chemicals

    International Nuclear Information System (INIS)

    Ji, Cheng; Jin, Xia; He, Jiangyan; Yin, Zhan

    2012-01-01

    Accumulating evidence indicates that a wide range of chemicals have the ability to interfere with the hypothalamic–pituitary–thyroid (HPT) axis. Novel endpoints should be evaluated in addition to existing methods in order to effectively assess the effects of these chemicals on the HPT axis. Thyroid-stimulating hormone subunit β (TSHβ) plays central regulatory roles in the HPT system. We identified the regulatory region that determines the expression level of zebrafish TSHβ in the anterior pituitary. In the transgenic zebrafish with EGFP driven by the TSHβ promoter, the similar responsive patterns between the expression levels of TSHβ:EGFP and endogenous TSHβ mRNA in the pituitary are observed following treatments with goitrogen chemicals and exogenous thyroid hormones (THs). These results suggest that the TSHβ:EGFP transgenic reporter zebrafish may be a useful alternative in vivo model for the assessment of chemicals interfering with the HPT system. Highlights: ► The promoter of zebrafish TSHβ gene has been identified. ► The stable TSHβ:EGFP transgenic zebrafish reporter germline has been generated. ► The EGFP in the transgenic fish recapitulated the pattern of pituitary TSHβ mRNA. ► The transgenic zebrafish may be an in vivo model for EDC assessment.

  9. Integrated Worker Radiation Dose Assessment for the K Basins

    International Nuclear Information System (INIS)

    NELSON, J.V.

    1999-01-01

    This report documents an assessment of the radiation dose workers at the K Basins are expected to receive in the process of removing spent nuclear fuel from the storage basins. The K Basins (K East and K West) are located in the Hanford 100K Area

  10. Excipient Usage Technical Risk Assessment for Generic Solid Dose Products

    Directory of Open Access Journals (Sweden)

    Ajay Babu Pazhayattil

    2017-09-01

    Full Text Available This paper proposes an assessment methodology for solid dose generic small molecule drug products. It addresses the ‘usage of the excipient’ portion of the trinomial by utilizing the systematic approach of Risk Identification, Risk Analysis and Risk Evaluation as per ICH Q9 Quality Risk Management outlined for developing risk control strategies. The assessment and maintenance of excipient risk profile is essential to minimize any potential risk associated to excipients impacting patients.

  11. Thyroid Disease

    Science.gov (United States)

    ... Institute. (2014). Thyroid Cancer . Bomeli, S.R., LeBeau, S.O., Ferris, R.L. (2010). Evalution of a Thyroid Nodule . ... Institute. (2014). Thyroid Cancer . Bomeli, S.R., LeBeau, S.O., Ferris, R.L. (2010). Evalution of a Thyroid Nodule . ...

  12. Estimating {sup 131}