WorldWideScience

Sample records for three-phase three-level converters

  1. Comparison of three-phase three-level voltage source inverter with intermediate dc–dc boost converter and quasi-Z-source inverter

    DEFF Research Database (Denmark)

    Panfilov, Dmitry; Husev, Oleksandr; Blaabjerg, Frede

    2016-01-01

    This study compares a three-phase three-level voltage source inverter with an intermediate dc-dc boost converter and a quasi-Z-source inverter in terms of passive elements values and dimensions, semiconductor stresses, and overall efficiency. A comparative analysis was conducted with relative...

  2. LCCT-derived three-level three-phase inverters

    DEFF Research Database (Denmark)

    Shults, Tatiana; Husev, Oleksandr; Blaabjerg, Frede

    2017-01-01

    Solutions for a family of the novel three-level neutral-point-clamped (NPC) inductor-capacitor-capacitor-transformer (LCCT)-derived three-phase inverters are described and compared. Component design guidelines and steady state analysis, current and voltage waveforms are given. The authors......' simulation results confirm the theoretical predictions. It was found that an asymmetrical three-level NPC LCCT-derived inverter with a single diode in the impedance source network is the most promising solution. Experimental results for an asymmetrical three-level NPC LCCT-derived inverter with a single...

  3. A THREE-PHASE BOOST DC-AC CONVERTER

    African Journals Online (AJOL)

    dc-ac converter (inverter) based on the dc-dc boost converters. ... Sliding mode controllers are designed to perform a robust control for the ... Computer simulations and spectral analysis demon- ... the conventional three-phase buck inverter,.

  4. Three-phase Resonant DC-link Converter

    OpenAIRE

    Munk-Nielsen, Stig

    1997-01-01

    The purpose of the project is to develop a three-phase resonant converter suitable for standard speed drives. The motivation for working with resonant converters is found in the problem of the standard converter type used today. In standard converter type Pulse Width Modulated-Voltage Source Inverter, PWM-VSI, the switches are subject to high current and voltage stress during switching, which causes losses. The fast switching of modern switches reduces switching losses. Unfortunately this pro...

  5. Three-phase Resonant DC-link Converter

    DEFF Research Database (Denmark)

    Munk-Nielsen, Stig

    The purpose of the project is to develop a three-phase resonant converter suitable for standard speed drives. The motivation for working with resonant converters is found in the problem of the standard converter type used today. In standard converter type Pulse Width Modulated-Voltage Source...... Inverter, PWM-VSI, the switches are subject to high current and voltage stress during switching, which causes losses. The fast switching of modern switches reduces switching losses. Unfortunately this procedure increased dv/dt and the size of the input/output filters of the PWM-SVI must be increased...

  6. A DSP controlled one-to-three phase matrix converter

    Energy Technology Data Exchange (ETDEWEB)

    Dubovsky, J.; Dobrucly, B; Tabacek, R.; Havrila, R. [Department of Electric Traction and Energetics Faculty of Electrical Engineering, University of Zilina (Slovakia)

    1997-12-31

    This paper deals with the theoretical analysis computer simulation and experimental results of IM fed by a one-to-three phase matrix converter which offers a unique solution for single phase electric traction applications. The proposed drive in comparison with currently used conventional drives reduces the number of power switching elements of the converter, which increases drives dependability and brings lower investment in power electronics used in drive. Further advantage is that the converter is controlled with nearly unity power factor which cuts down the operational expenses and offers higher overall performance of the drive. (orig.) 6 refs.

  7. Three-level boost converter with zero voltage transition

    Directory of Open Access Journals (Sweden)

    Kuo-Ing Hwu

    2017-06-01

    Full Text Available As compared with the traditional boost converter, the three-level boost converter possesses several advantages, such as lower switch voltage stresses and lower inductor current ripple. To improve the efficiency, this paper proposes a zero voltage transition (ZVT three-level boost converter. With the proposed ZVT circuit, the switches can achieve soft switching. Moreover, by using the voltage balance control, the output voltage can be equally across the output capacitors. In this study, the effectiveness of the proposed topology is verified by the experimental results based on the field-programmable gate array control.

  8. A NOVEL THREE PHASE UNITY POWER FACTOR CONVERTER

    Directory of Open Access Journals (Sweden)

    Bekir Sami SAZAK

    1998-03-01

    Full Text Available The proposed unity power factor converter system which is able to operate from a 150V three-phase supply whilst delivering the required 200V DC voltage has been built and tested. This circuit functions as a high power factor low harmonic rectifier based on the concept that the peak capacitor voltages are proportional to the line input currents. Hence the low frequency components of the capacitor voltages are also approximately proportional to the line input currents. The system can be designed to achieve nearly sinusoidal supply input currents, when operated with discontinuous resonant capacitor voltages Output power control is achieved by variations of the IGBTs switching frequency. The converter is therefore able to compensate for any changes in the load resistance. The proposed topology offers advantages, including: a relatively simple power, control and protection circuits, high power capability, and high converter efficiencies.

  9. A Three-level 4 x 3 Conventinal Matrix Converter

    DEFF Research Database (Denmark)

    Rong, Runjie; Loh, Poh Chiang; Wang, Peter

    2007-01-01

    This paper proposes a topology of a three-level 4 × 3 conventional matrix converter with 12 bi-directional switches. PWM control and modulation index compensation have been investigated. Operation theory has been verified by the simulation results using Matlab. The simulation results show...

  10. Multilevel Converter by Cascading Two-Level Three-Phase Voltage Source Converter

    Directory of Open Access Journals (Sweden)

    Abdullrahman A. Al-Shamma’a

    2018-04-01

    Full Text Available This paper proposes a topology using isolated, cascaded multilevel voltage source converters (VSCs and employing two-winding magnetic elements for high-power applications. The proposed topology synthesizes 6 two-level, three-phase VSCs, so the power capability of the presented converter is six times the capability of each VSC module. The characteristics of the proposed topology are demonstrated through analyzing its current relationships, voltage relationships and power capability in detail. The power rating is equally shared among the VSC modules without the need for a sharing algorithm; thus, the converter operates as a single three-phase VSC. The comparative analysis with classical neutral-point clamped, flying capacitor and cascaded H-bridge exhibits the superior features of fewer insulated gate bipolar transistors (IGBTs, capacitor requirement and fewer diodes. To validate the theoretical performance of the proposed converter, it is simulated in a MATLAB/Simulink environment and the results are experimentally demonstrated using a laboratory prototype.

  11. Research on Parallel Three Phase PWM Converters base on RTDS

    Science.gov (United States)

    Xia, Yan; Zou, Jianxiao; Li, Kai; Liu, Jingbo; Tian, Jun

    2018-01-01

    Converters parallel operation can increase capacity of the system, but it may lead to potential zero-sequence circulating current, so the control of circulating current was an important goal in the design of parallel inverters. In this paper, the Real Time Digital Simulator (RTDS) is used to model the converters parallel system in real time and study the circulating current restraining. The equivalent model of two parallel converters and zero-sequence circulating current(ZSCC) were established and analyzed, then a strategy using variable zero vector control was proposed to suppress the circulating current. For two parallel modular converters, hardware-in-the-loop(HIL) study based on RTDS and practical experiment were implemented, results prove that the proposed control strategy is feasible and effective.

  12. A Three-Phase Boost DC-AC Converter | Odeh | Nigerian Journal of ...

    African Journals Online (AJOL)

    Sliding mode controllers are designed to perform a robust control for the three boost dc-dc converters. Computer simulations and spectral analysis demonstrate the feasibility of the proposed three-phase inverter. The inverter is intended to be used in three-phase electric drives and uninterruptible power supply (UPS) ...

  13. High-power three-port three-phase bidirectional DC-DC converter

    NARCIS (Netherlands)

    Tao, H.; Duarte, J.L.; Hendrix, M.A.M.

    2007-01-01

    This paper proposes a three-port three-phase bidirectional dc-dc converter suitable for high-power applications. The converter combines a slow primary source and a fast storage to power a common load (e.g., an inverter). Since this type of system is gaining popularity in sustainable energy

  14. Sharing of nonlinear load in parallel-connected three-phase converters

    DEFF Research Database (Denmark)

    Borup, Uffe; Blaabjerg, Frede; Enjeti, Prasad N.

    2001-01-01

    compensation are connected in parallel. Without the new solution, they are normally not able to distinguish the harmonic currents that flow to the load and harmonic currents that circulate between the converters. Analysis and experimental results on two 90-kVA 400-Hz converters in parallel are presented......In this paper, a new control method is presented which enables equal sharing of linear and nonlinear loads in three-phase power converters connected in parallel, without communication between the converters. The paper focuses on solving the problem that arises when two converters with harmonic....... The results show that both linear and nonlinear loads can be shared equally by the proposed concept....

  15. Common mode noise in three-level DC-DC converters

    CSIR Research Space (South Africa)

    Grobler, Inus

    2009-09-01

    Full Text Available that three-level buck DC-DC converters in general generate much lower common mode currents than conventional two-level buck converters. Further, reductions in common mode currents are achieved by using the improved three-level topologies that have been...

  16. Control and Modeling of Push-Pull Forward Three-Level Converter for Microgrid

    DEFF Research Database (Denmark)

    Yao, Zhilei; Xu, Jing; Guerrero, Josep M.

    2015-01-01

    Renewable energy sources are widely used in microgrid. Output voltage of them is often low and varies widely. Because diodes in three-level legs in traditional three-level (TL) converter are substituted by MOSFETs, the push-pull forward (PPF) TL converter is very suitable for wide and low...

  17. An Integrated Inductor For Parallel Interleaved Three-Phase Voltage Source Converters

    DEFF Research Database (Denmark)

    Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand; Teodorescu, Remus

    2016-01-01

    Three phase Voltage Source Converters (VSCs) are often connected in parallel to realize high current output converter system. The harmonic quality of the resultant switched output voltage can be improved by interleaving the carrier signals of these parallel connected VSCs. As a result, the line...... of the state-of-the-art filtering solution. The performance of the integrated inductor is also verified by the experimental measurements....

  18. A three-phase to three-phase series-resonant power converter with optimal input current waveforms, Part II: implementation and results

    NARCIS (Netherlands)

    Huisman, H.

    1988-01-01

    For pt.I see ibid., vol.35, no.2, p.263-8 (1988). A 15 kW three-phase prototype series-resonant power converter is constructed. The converter features sinusoidal output voltage and sinusoidal input currents. The control concepts and necessary electronics, as well as the layout of the power circuit,

  19. Maximum power point tracking techniques for wind energy systems using three levels boost converter

    Science.gov (United States)

    Tran, Cuong Hung; Nollet, Frédéric; Essounbouli, Najib; Hamzaoui, Abdelaziz

    2018-05-01

    This paper presents modeling and simulation of three level Boost DC-DC converter in Wind Energy Conversion System (WECS). Three-level Boost converter has significant advantage compared to conventional Boost. A maximum power point tracking (MPPT) method for a variable speed wind turbine using permanent magnet synchronous generator (PMSG) is also presented. Simulation of three-level Boost converter topology with Perturb and Observe algorithm and Fuzzy Logic Control is implemented in MATLAB/SIMULINK. Results of this simulation show that the system with MPPT using fuzzy logic controller has better performance to the Perturb and Observe algorithm: fast response under changing conditions and small oscillation.

  20. Power loss benchmark of nine-switch converters in three-phase online-UPS application

    DEFF Research Database (Denmark)

    Qin, Zian; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    Three-phase online-UPS is an appropriate application for the nine-switch converter, where its high voltage stress of the power device caused by the reduced switch feature can be relieved significantly. Its power loss and loss distribution still have the flexibility from the control point of view...... as parameters like modulation index and phase angle of the load are taken into account. The benchmark of power loss will become a guidance for the users to make best use of the advantages and bypass the disadvantages of nine-switch converters. The results are finally verified on a 1.5 kW prototype....

  1. Energy-efficient three-phase bidirectional converter for grid-connected storage applications

    International Nuclear Information System (INIS)

    Colmenar-Santos, Antonio; Linares-Mena, Ana-Rosa; Velázquez, Jesús Fernández; Borge-Diez, David

    2016-01-01

    Highlights: • Storage control system developed based on AC DC three phase bidirectional converter. • Bidirectional AC DC converter for storage integration into distribution grids. • Efficiencies over 98% for values over 30% of the bidirectional converter rated power. • Sensitivity analysis of the parameters set by the transmission system operator. • Low-cost option for control and integration of new grid-connected storage systems. - Abstract: Grid connected energy storage systems are expected to play an essential role in the development of Smart Grids, providing, among other benefits, ancillary services to power grids. It is therefore crucial to design and develop control and conversion systems that represent the key instrument where intelligence for decision-making is applied, in order to validate and ensure its optimal operation as part and parcel of the electrical system. The present research describes the design and development of a battery energy storage system based on an AC-DC three-phase bidirectional converter capable of operating either in charge mode to store electrical energy, or in discharge mode to supply load demands. The design is modelled with MATLAB® Simulink® environment in order to evaluate the performance during load variations. Moreover, the assessment is complemented by a global sensitivity analysis for variations in the operating parameters set by the transmission system operator. The effectiveness of the simulation is confirmed by implementing the system and carrying out grid connection tests, obtaining efficiencies over 98% for values over the 30% of the bidirectional converter rated power.

  2. Hybrid Modulation of Bidirectional Three-Phase Dual-Active-Bridge DC Converters for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Yen-Ching Wang

    2016-06-01

    Full Text Available Bidirectional power converters for electric vehicles (EVs have received much attention recently, due to either grid-supporting requirements or emergent power supplies. This paper proposes a hybrid modulation of the three-phase dual-active bridge (3ΦDAB converter for EV charging systems. The designed hybrid modulation allows the converter to switch its modulation between phase-shifted and trapezoidal modes to increase the conversion efficiency, even under light-load conditions. The mode transition is realized in a real-time manner according to the charging or discharging current. The operation principle of the converter is analyzed in different modes and thus design considerations of the modulation are derived. A lab-scaled prototype circuit with a 48V/20Ah LiFePO4 battery is established to validate the feasibility and effectiveness.

  3. A Component-Reduced Zero-Voltage Switching Three-Level DC-DC Converter

    DEFF Research Database (Denmark)

    Qin, Zian; Pang, Ying; Wang, Huai

    2016-01-01

    The basic Zero-Voltage Switching (ZVS) three-level DC-DC converter has one clamping capacitor to realize the ZVS of the switches, and two clamping diodes to clamp the voltage of the clamping capacitor. In order to reduce the reverse recovery loss of the diode as well as its cost, this paper...... proposes to remove one of the clamping diodes in basic ZVS three-level DC-DC converter. With less components, the proposed converter can still have a stable clamping capacitor voltage, which is clamped at half of the dc link voltage. Moreover, the ZVS performance will be influenced by removing the clamping...

  4. Three-Level AC-DC-AC Z-Source Converter Using Reduced Passive Component Count

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Gao, Feng; Tan, Pee-Chin

    2009-01-01

    This paper presents a three-level ac-dc-ac Z-source converter with output voltage buck-boost capability. The converter is implemented by connecting a low-cost front-end diode rectifier to a neutral-point-clamped inverter through a single X-shaped LC impedance network. The inverter is controlled...... to switch with a three-level output voltage, where the middle neutral potential is uniquely tapped from the star-point of a wye-connected capacitive filter placed before the front-end diode rectifier for input current filtering. Through careful control, the resulting converter can produce the correct volt...

  5. Control and design of full-bridge three-level converter for renewable energy sources

    DEFF Research Database (Denmark)

    Yao, Zhilei; Xu, Jing; Guerrero, Josep M.

    2015-01-01

    Output voltage of renewable energy sources, such as fuel cell and PV cell, is often low and varies widely with load and environmental conditions. Therefore, the high step-up DC-DC converter is needed between renewable energy sources and the grid-connected inverter. However, voltage stress...... of rectifier diodes is high and filter is large in traditional voltage-source converters in a wide input-voltage range. In order to solve the aforementioned problems, a full-bridge (FB) three-level (TL) converter is proposed. It can operate at both two-level and three-level modes, so it is suitable for wide...

  6. Use of Three-Level Power Converters in Wind-Driven Permanent-Magnet Synchronous Generators with Unbalanced Loads

    Directory of Open Access Journals (Sweden)

    Ming-Hung Chen

    2015-06-01

    Full Text Available This paper describes the design and implementation of three-level power converters for wind-driven permanent-magnet synchronous generators with unbalanced loads. To increase voltage stress and reduce current harmonics in the electrical power generated by a wind generator, a three-phase, three-level rectifier is used. Because a synchronous rotating frame is used on the AC-input side, the use of a neutral-point-clamped controller is proposed to increase the power factor to unity and reduce current harmonics. Furthermore, a novel six-leg inverter is proposed for transferring energy from the DC voltage to a three-phase, four-wire AC source with a constant voltage and a constant frequency. The power converters also contain output transformers and filters for power buffering and filtering, respectively. All three output phase voltages are fed back to control the inverter output during load variations. A digital signal processor is used as the core control device for implementing a 1.5 kV, 75 kW drive system. Experimental data show that the power factor is successfully increased to unity and the total current harmonic distortion is 3.2% on the AC-input side. The entire system can attain an efficiency of 91%, and the voltage error between the upper and lower capacitors is approximately zero. Experimental results that confirm the high performance of the proposed system are presented.

  7. New three-phase ac-ac converter incorporating three-phase boost integrated ZVT bridge and single-phase HF link

    International Nuclear Information System (INIS)

    Abdelhamid, Tamer H.; Sabzali, Ahmad J.

    2008-01-01

    This paper presents a new zero voltage transition (ZVT), power factor corrected three phase ac-ac converter with single phase high frequency (HF) link. It is a two stage converter; the first stage is a boost integrated bridge converter (combination of a 3 ph boost converter and a bridge converter) operated at fixed frequency and that operates in two modes at ZVT for all switches and establishes a 1 ph square wave HF link. The second stage is a bi-directional pulse width modulation (PWM) 3 ph bridge that converts the 1 ph HF link to a 3 ph voltage using a novel switching strategy. The converter modes of operation and key equations are outlined. Simulation of the overall system is conducted using Simulink. The switching strategy and its corresponding control circuit are clearly described. Experimental verification of the simulation is conducted for a prototype of 100 V, 500 W at 10 kHz link frequency

  8. Modeling and reliability analysis of three phase z-source AC-AC converter

    Directory of Open Access Journals (Sweden)

    Prasad Hanuman

    2017-12-01

    Full Text Available This paper presents the small signal modeling using the state space averaging technique and reliability analysis of a three-phase z-source ac-ac converter. By controlling the shoot-through duty ratio, it can operate in buck-boost mode and maintain desired output voltage during voltage sag and surge condition. It has faster dynamic response and higher efficiency as compared to the traditional voltage regulator. Small signal analysis derives different control transfer functions and this leads to design a suitable controller for a closed loop system during supply voltage variation. The closed loop system of the converter with a PID controller eliminates the transients in output voltage and provides steady state regulated output. The proposed model designed in the RT-LAB and executed in a field programming gate array (FPGA-based real-time digital simulator at a fixedtime step of 10 μs and a constant switching frequency of 10 kHz. The simulator was developed using very high speed integrated circuit hardware description language (VHDL, making it versatile and moveable. Hardware-in-the-loop (HIL simulation results are presented to justify the MATLAB simulation results during supply voltage variation of the three phase z-source ac-ac converter. The reliability analysis has been applied to the converter to find out the failure rate of its different components.

  9. A zero-voltage-switched three-phase interleaved buck converter

    Science.gov (United States)

    Hsieh, Yao-Ching; Huang, Bing-Siang; Lin, Jing-Yuan; Pham, Phu Hieu; Chen, Po-Hao; Chiu, Huang-Jen

    2018-04-01

    This paper proposes a three-phase interleaved buck converter which is composed of three identical paralleled buck converters. The proposed solution has three shunt inductors connected between each other of three basic buck conversion units. With the help of the shunt inductors, the MOSFET parasitic capacitances will resonate to achieve zero-voltage-switching. Furthermore, the decreasing rate of the current through the free-wheeling diodes is limited, and therefore, their reverse-recovery losses can be minimised. The active power switches are controlled by interleaved pulse-width modulation signals to reduce the input and output current ripples. Therefore, the filtering capacitances on the input and output sides can be reduced. The power efficiency is measured to be as high as 98% in experiment with a prototype circuit.

  10. Power Controllability of Three-phase Converter with Unbalanced AC Source

    DEFF Research Database (Denmark)

    Ma, Ke; Liserre, Marco; Blaabjerg, Frede

    2013-01-01

    Three-phase DC-AC power converters suffer from power oscillation and overcurrentt problems in case of unbalanced AC source voltage that can be caused by grid/generator faults. Existing solutions to handle these problems are properly selecting and controlling the positive and negative sequence...... currents. In this work a new series of control strategies which utilize the zero-sequence components are proposed to enhance the power control ability under this adverse conditions. It is concluded that by introducing proper zero sequence current controls and corresponding circuit configurations, the power...... converter can enable more flexible control targets, achieving better performances in the delivered power and load current when suffering from unbalanced AC sources....

  11. Power Controllability of Three-phase Converter with Unbalanced AC Source

    DEFF Research Database (Denmark)

    Ma, Ke; Chen, Wenjie; Liserre, Marco

    2015-01-01

    Three-phase DC-AC power converters suffer from power oscillation and overcurrent problems in case of unbalanced AC source voltage that can be caused by grid/generator faults. Existing solutions to handle these problems are properly selecting and controlling the positive and negative sequence...... currents. In this work a new series of control strategies which utilize the zerosequence components are proposed to enhance the power control ability under this adverse condition. It is concluded that by introducing proper zero sequence current controls and corresponding circuit configurations, the power...... converter can enable more flexible control targets, achieving better performances in the delivered power and load current when suffering from unbalanced AC voltage....

  12. An analytical inductor design procedure for three-phase PWM converters in power factor correction applications

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Niroumand, Farideh Javidi; Haase, Frerk

    2015-01-01

    This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyze...... to calculate the core loss in the PFC application. To investigate the impact of the dc link voltage level, two inductors for different dc voltage levels are designed and the results are compared.......This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyzes...... circuit is used to provide the inductor current harmonic spectrum. Therefore, using the harmonic spectrum, the low and high frequency copper losses are calculated. The high frequency minor B-H loops in one switching cycle are also analyzed. Then, the loss map provided by the measurement setup is used...

  13. A new interleaved double-input three-level boost converter

    DEFF Research Database (Denmark)

    Chen, Jianfei; Hou, Shiying; Sun, Tao

    2016-01-01

    This paper proposes a new interleaved double-input three-level Boost (DITLB) converter, which is composed of two boost converters indirectly in series. Thus, a high voltage gain, together with a low component stress and a small input current ripple due to the interleaved control scheme, is achieved....... The operating principle of the DITLB converter under the individual supplying power (ISP) and simultaneous supplying power (SSP) mode is analyzed. In addition, closed-loop control strategies composed of a voltage-current loop and a voltage-balance loop, have been researched to make the converter operate...... steadily and to alleviate the neutral-point imbalance issue. Experimental results verify correctness and feasibility of the proposed topology and control strategies....

  14. A New Topology for Interline Dynamic Voltage Restorer Based on Direct Three-Phase Converter

    Directory of Open Access Journals (Sweden)

    E. Babaei

    2016-03-01

    Full Text Available In this paper, a new topology for Interline Dynamic Voltage Restorer (IDVR is proposed. This topology contains two direct three-phase converters which have been connected together by a common fictitious dc-link. According to the kind of the disturbances, both of the converters can be employed as a rectifier or inverter. The converters receive the required compensation energy from the gird through the direct link which is provided by the dual-proposed switches. Due to the lack of the huge storage elements, the practical prototype of the proposed topology is more economical in comparison with the traditional structure. Moreover, compensating for long time duration is possible due to the unlimited eternal energy which is provided from the grids. The low volume, cost and weight are the additional features of the proposed topology in comparison with traditional types. This topology is capable to compensate both of the balanced and unbalanced disturbances. Furthermore, restoring the deep sags and power outages will be possible with the support from the other grid. Unlike the conventional topologies, the capability of compensation is independent from the power flow and the power factor of each grid. The performance of the proposed IDVR topology is validated by computer simulation with PSCAD/EMTDC software.

  15. Grid Integration of Single Stage Solar PV System using Three-level Voltage Source Converter

    Science.gov (United States)

    Hussain, Ikhlaq; Kandpal, Maulik; Singh, Bhim

    2016-08-01

    This paper presents a single stage solar PV (photovoltaic) grid integrated power generating system using a three level voltage source converter (VSC) operating at low switching frequency of 900 Hz with robust synchronizing phase locked loop (RS-PLL) based control algorithm. To track the maximum power from solar PV array, an incremental conductance algorithm is used and this maximum power is fed to the grid via three-level VSC. The use of single stage system with three level VSC offers the advantage of low switching losses and the operation at high voltages and high power which results in enhancement of power quality in the proposed system. Simulated results validate the design and control algorithm under steady state and dynamic conditions.

  16. Control method of Three-phase Four-leg converter based on repetitive control

    Science.gov (United States)

    Hui, Wang

    2018-03-01

    The research chose the magnetic levitation force of wind power generation system as the object. In order to improve the power quality problem caused by unbalanced load in power supply system, we combined the characteristics and repetitive control principle of magnetic levitation wind power generation system, and then an independent control strategy for three-phase four-leg converter was proposed. In this paper, based on the symmetric component method, the second order generalized integrator was used to generate the positive and negative sequence of signals, and the decoupling control was carried out under the synchronous rotating reference frame, in which the positive and negative sequence voltage is PI double closed loop, and a PI regulator with repetitive control was introduced to eliminate the static error regarding the fundamental frequency fluctuation characteristic of zero sequence component. The simulation results based on Matlab/Simulink show that the proposed control project can effectively suppress the disturbance caused by unbalanced loads and maintain the load voltage balance. The project is easy to be achieved and remarkably improves the quality of the independent power supply system.

  17. The Three-Phase Power Router and Its Operation with Matrix Converter toward Smart-Grid Applications

    Directory of Open Access Journals (Sweden)

    Alexandros Kordonis

    2015-04-01

    Full Text Available A power router has been recently developed for both AC and DC applications that has the potential for smart-grid applications. This study focuses on three-phase power switching through the development of an experimental setup which consists of a three-phase direct AC/AC matrix converter with a power router attached to its output. Various experimental switching scenarios with the loads connected to different input sources were investigated. The crescent introduction of decentralized power generators throughout the power-grid obligates us to take measurements for a better distribution and management of the power. Power routers and matrix converters have great potential to succeed this goal with the help of power electronics devices. In this paper, a novel experimental three-phase power switching was achieved and the advantages of this operation are presented, such as on-demand and constant power supply at the desired loads.

  18. Performance evaluation of a three-phase dual active bridge DC-DC converter with different transformer winding configurations

    NARCIS (Netherlands)

    Baars, N.; Everts, J.; Wijnands, K.; Lomonova, E.

    2016-01-01

    This paper investigates the impact of three transformer winding configurations, i.e. the Y-Y, the Y-Delta, and the Delta-Delta configuration, on the performance of a three-phase dual active bridge (DAB) dc–dc converter. For each configuration, equations for the phase currents, power flow, and zero

  19. Chapter 5: Modeling and Control of Three-Phase AC/DC Converter Including Phase-Locked Loop

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2018-01-01

    In this chapter, a mathematical model of the power circuit of a three-phase AC/DC converter is developed in the stationary and synchronous reference frames. Then, the operation principle of the phasor locked loop is addressed to exact the angle information of the power grid to realize the accurat...

  20. Control of improved full-bridge three-level DC/DC converter for wind turbines in a DC grid

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    transformer in the IFBTL dc/dc converter. A modulation strategy, including two operation modes, is proposed for the IFBTL dc/dc converter. Then, a voltage balancing control strategy is proposed for the IFBTL dc/dc converter. Furthermore, the control of the wind turbine based on the IFBTL dc/dc converter......This paper presents an improved full-bridge three-level (IFBTL) dc/dc converter for a wind turbine in a dc grid by inserting a passive filter into the dc/dc converter to improve the performance of the converter. The passive filter can effectively reduce the voltage stress of the medium frequency...

  1. A Single Phase to Three Phase PFC Half-Bridge Converter Using BLDC Drive with SPWM Technique.

    OpenAIRE

    Srinu Duvvada; Manmadha Kumar B

    2014-01-01

    In this paper, a buck half-bridge DC-DC converter is used as a single-stage power factor correction (PFC) converter for feeding a voltage source inverter (VSI) based permanent magnet brushless DC motor (BLDC) drive. The front end of this PFC converter is a diode bridge rectifier (DBR) fed from single-phase AC mains. The BLDC is used to drive a compressor load of an air conditioner through a three-phase VSI fed from a controlled DC link voltage. The speed of the compressor is controlled to ach...

  2. A Three-Phase Dual-Input Matrix Converter for Grid Integration of Two AC Type Energy Resources

    DEFF Research Database (Denmark)

    Liu, Xiong; Wang, Peng; Chiang Loh, Poh

    2013-01-01

    This paper proposes a novel dual-input matrix converter (DIMC) to integrate two three-phase ac type energy resources to a power grid. The proposed matrix converter is developed based on the traditional indirect matrix converter under reverse power flow operation mode, but with its six......-to-output voltage boost capability since power flows from the converter’s voltage source side to its current source side. Commanded currents can be extracted from the two input sources to the grid. The proposed control and modulation schemes guarantee sinusoidal input and output waveforms as well as unity input......-switch voltage source converter replaced by a nine-switch configuration. With the additional three switches, the proposed DIMC can provide six in put terminals, which make it possible to integrate two independent ac sources into a single grid-tied power electronics interface. The proposed converter has input...

  3. Vector control of three-phase AC/DC front-end converter

    Indian Academy of Sciences (India)

    Section 4 presents the simulation and experimental results of FEC. Section 5 discusses the problems associated with the starting process of ..... A 250-kVA vector-controlled FEC is simulated with MATLAB/SIMULINK. ..... Ghosh R 2007 Modelling, Analysis and Control of Single-phase and Three-phase PWM Rectifiers.

  4. Control scheme of three-level H-bridge converter for interfacing between renewable energy resources and AC grid

    DEFF Research Database (Denmark)

    Pouresmaeil, Edris; Montesinos-Miracle, Daniel; Gomis-Bellmunt, Oriol

    2011-01-01

    This paper presents a control strategy of multilevel converters for integration of renewable energy resources into power grid. The proposed technique provides compensation for active, reactive, and harmonic current components of grid-connected loads. A three-level H-bridge converter is proposed a...

  5. Design of Two Feeder Three Phase Four Wire Distribution System Utilizing Multi Converter UPQC with Fuzzy Logic Controller

    Directory of Open Access Journals (Sweden)

    Chandra Babu Paduchuri

    2014-01-01

    Full Text Available This paper proposes the instantaneous p-q theory based fuzzy logic controller (FLC for multi converter unified power quality conditioner (MC-UPQC to mitigate power quality issues in two feeders three-phase four-wire distribution systems. The proposed system is extended system of the existing one feeder three-phase four-wire distribution system, which is operated with UPQC. This system is employed with three voltage source converters, which are connected commonly to two feeder distribution systems. The performance of this proposed system used to compensate voltage sag, neutral current mitigation and compensation of voltage and current harmonics under linear and nonlinear load conditions. The neutral current flowing in series transformers is zero in the implementation of the proposed system. The simulation performance analysis is carried out using MATLAB.

  6. Current Controller for Multi-level Front-end Converter and Its Digital Implementation Considerations on Three-level Flying Capacitor Topology

    Science.gov (United States)

    Tekwani, P. N.; Shah, M. T.

    2017-10-01

    This paper presents behaviour analysis and digital implementation of current error space phasor based hysteresis controller applied to three-phase three-level flying capacitor converter as front-end topology. The controller is self-adaptive in nature, and takes the converter from three-level to two-level mode of operation and vice versa, following various trajectories of sector change with the change in reference dc-link voltage demanded by the load. It keeps current error space phasor within the prescribed hexagonal boundary. During the contingencies, the proposed controller takes the converter in over modulation mode to meet the load demand, and once the need is satisfied, controller brings back the converter in normal operating range. Simulation results are presented to validate behaviour of controller to meet the said contingencies. Unity power factor is assured by proposed controller with low current harmonic distortion satisfying limits prescribed in IEEE 519-2014. Proposed controller is implemented using TMS320LF2407 16-bit fixed-point digital signal processor. Detailed analysis of numerical format to avoid overflow of sensed variables in processor, and per-unit model implementation in software are discussed and hardware results are presented at various stages of signal conditioning to validate the experimental setup. Control logic for the generation of reference currents is implemented in TMS320LF2407A using assembly language and experimental results are also presented for the same.

  7. A Transformer-less Partial Power Boost Converter for PV Applications Using a Three-Level Switching Cell

    Energy Technology Data Exchange (ETDEWEB)

    Agamy, Mohammed; Harfman-Todorovic, Maja; Elasser, Ahmed; Essakiappan, Somasundaram

    2013-03-01

    Photovoltaic architectures with distributed power electronics provide many advantages in terms of energy yield as well as system level optimization. As the power level of the solar farm increases it becomes more beneficial to increase the dc collection network voltage, which requires the use of power devices with higher voltage ratings, and thus making the design of efficient, low cost, distributed power converters more challenging. In this paper a simple partial power converter topology is proposed. The topology is implemented using a three-level switching cell, which allows the use of semiconductor devices with lower voltage rating; thus improving design and performance and reducing converter cost. This makes the converters suitable for use for medium to high power applications where dc-link voltages of 600V~1kV may be needed without the need for high voltage devices. Converter operation and experimental results are presented for two partial power circuit variants using three-level switching cells.

  8. Control Strategies for Trap Filter Interfaced Three-Phase Grid Connected Converters

    DEFF Research Database (Denmark)

    Min, Huang

    In order to utilize renewable energy systems power electronics are needed to convert the energy to grid. The AC-DC and DC-AC power conversion are dominant in wind power system and photovoltaic system. However, the use of PWM scheme introduces undesirable harmonics. In order to enhance the grid...... damping in order to stabilize the whole system with resonance issue. LC trap filter application for current source converters to reduce the size of the filter and get a higher power factor....... integration of the renewable energy systems, the filter plays an important role. Even though this topic has already been widely studied, there are many optimizations and problems should be solved. How to design a filter for grid-connected converters in distributed generation system to get a lower loss...

  9. Improved Design Methods for Robust Single- and Three-Phase ac-dc-ac Power Converters

    DEFF Research Database (Denmark)

    Qin, Zian

    . The approaches for improving their performance, in terms of the voltage stress, efficiency, power density, cost, loss distribution, and temperature, will be studied. The structure of the thesis is as follows, Chapter 1 presents the introduction and motivation of the whole project as well as the background...... becomes a emerging challenge. Accordingly, installation of sustainable power generators like wind turbines and solar panels has experienced a large increase during the last decades. Meanwhile, power electronics converters, as interfaces in electrical system, are delivering approximately 80 % electricity...... back-to-back, and meanwhile improve the harmonics, control flexibility, and thermal distribution between the switches. Afterwards, active power decoupling methods for single-phase inverters or rectifiers that are similar to the single-phase ac-dc-ac converter, are studied in Chapter 4...

  10. General phase-frequency shifting in the three-phase inductor-converter bridge

    International Nuclear Information System (INIS)

    Ehsani, M.; Kustom, R.L.; Fuja, R.E.; Barnard, T.J.

    1979-01-01

    A fundamental method of shifting phase frequency in the inductor-converter bridge (ICB) for the purpose of controlling the power in real time is presented. Transient switching sequences needed to implement phase-frequency shifting can be developed by the use of this method and the other five system constraints. Two of the constraints that have been expressed in equation form so far are presented. Finally, an alternative algorithm for computing the frequency shifting transient sequences in real time is suggested

  11. A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions

    DEFF Research Database (Denmark)

    Rodríguez, P.; Luna, A.; Muñoz-Aguilar, R. S.

    2012-01-01

    synchronization method for three-phase three-wire networks, namely dual second-order generalized integrator (SOGI) frequency-locked loop. The method is based on two adaptive filters, implemented by using a SOGI on the stationary αβ reference frame, and it is able to perform an excellent estimation......Grid synchronization algorithms are of great importance in the control of grid-connected power converters, as fast and accurate detection of the grid voltage parameters is crucial in order to implement stable control strategies under generic grid conditions. This paper presents a new grid...

  12. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...

  13. Operation and thermal loading of three-level Neutral-Point-Clamped wind power converter under various grid faults

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede; Liserre, Marco

    2012-01-01

    In order to fulfill the continuous growing grid-side demands, the full-scale power converters are becoming more and more popular in the wind power application. Nevertheless, the more severe loading of the power semiconductor devices in the full-scale power converters, especially during Low Voltage...... Ride Through (LVRT) operation under grid faults, may compromise the reliability of the system and consequently further increase its cost. In this paper, the impact of various grid faults on a three-level Neutral-Point-Clamped (3L-NPC) grid-converter in terms of thermal loading of power semiconductor...

  14. A Review on Current Reference Calculation of Three-Phase Grid-Connected PV Converters under Grid Faults

    DEFF Research Database (Denmark)

    Afshari, Ehsan; Moradi, Gholam Reza; Yang, Yongheng

    2017-01-01

    Unbalanced grid voltage dips may lead to unbalanced non-sinusoidal current injections, dc-link voltage oscillations, and active and/or reactive power oscillations with twice the grid fundamental frequency in three-phase grid-connected Photovoltaic (PV) systems. Double grid frequency oscillations...... of the most important issues that should be coped with for a reliable operation of grid-connected converters under unbalanced grid faults. Accordingly, this paper reviews the existing CRC methods and presents a current reference generation method, which can have 16 unique modes. Issues are also investigated...... at the dc-link of the conventional two-stage PV inverters can further deteriorate the dc-link capacitor, which is one of the most life-limiting components in the system. Proper controls of these converters may efficiently address this problem. In those solutions, Current Reference Calculation (CRC) is one...

  15. Operational limits of a three level neutral point clamped converter used for controlling a hybrid energy storage system

    International Nuclear Information System (INIS)

    Etxeberria, A.; Vechiu, I.; Camblong, H.; Kreckelbergh, S.; Bacha, S.

    2014-01-01

    Highlights: • The control of a hybrid storage system using a Three Level NPC converter is analysed. • A sinusoidal PWM with an offset injection is used to control the storage system. • The operation of the selected converter is analysed in its entire operation range. • The operational limits of the Three Level NPC converter are defined. - Abstract: This work analyses the use of a Three-Level Neutral Point Clamped (3LNPC) converter to control the power flow of a Hybrid Energy Storage System (HESS) and at the same time interconnect it with the common AC bus of a microgrid. Nowadays there is not any storage technology capable of offering a high energy storage capacity, a high power capacity and a fast response at the same time. Therefore, the necessity of hybridising more than one storage technology is a widely accepted idea in order to satisfy the mentioned requirements. This work shows how the operational limits of the 3LNPC converter can be calculated and integrated in a control structure to facilitate an optimal use of the HESS according to the rules fixed by the user

  16. Medium voltage three-level converters for the grid connection of a multi-MW wind turbine

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2009-01-01

    Three-level (3L) neutral point clamped (NPC), flying capacitor (FC), and H-bridge (HB) voltage source converters (VSCs) as a grid-side full-scale medium voltage (MV) converter are modeled, controlled, and simulated for the grid connection of a hypothetical 6MW wind turbine. Via the converter...... topological features and the simulation results demonstrating the converter performance, these three 3L-VSCs are discussed and compared in terms of power density and reliability, which can be considered as two of the most important criteria for the converters placed in wind turbine nacelles. Given the grid...... connection circuit (without capacitive switching ripple filters), the 3L-HB-VSC is expected to be superior with respect to power density and reliability over the 3L-NPC- and -FC-VSCs....

  17. Medium Voltage Three-level Converters for the Grid Connection of aMulti-MW Wind Turbine

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2009-01-01

    Three-level (3L) neutral point clamped (NPC), flying capacitor (FC), and H-bridge (HB) voltage source converters (VSCs) as a grid-side full-scale medium voltage (MV) converter are modeled, controlled, and simulated for the grid connection of a hypothetical 6MW wind turbine. Via the converter...... topological features and the simulation results demonstrating the converter performance, these three 3L-VSCs are discussed and compared in terms of power density and reliability, which can be considered as two of the most important criteria for the converters placed in wind turbine nacelles. Given the grid...... connection circuit (without capacitive switching ripple filters), the 3L-HB-VSC is expected to be superior with respect to power density and reliability over the 3L-NPC- and -FC-VSCs....

  18. Indirect Matrix Converter for Hybrid Electric Vehicle Application with Three-Phase and Single-Phase Outputs

    Directory of Open Access Journals (Sweden)

    Yeongsu Bak

    2015-04-01

    Full Text Available This paper presents an indirect matrix converter (IMC topology for hybrid electric vehicle (HEV application with three-phase and single-phase outputs. The HEV includes mechanical, electrical, control, and electrochemical systems among others. In the mechanical system, a traction motor and a compressor motor are used to drive the HEV. The traction motor and the compressor motor are usually operated as three-phase and single-phase motors, respectively. In this respect, a dual AC-drive system can operate the traction and the compressor motor simultaneously. Furthermore, compared to a conventional dual matrix converter system, the proposed topology can reduce the number of switches that the dual outputs share with a DC-link. The application of this system for HEV has advantages, like long lifetime and reduced volume due to the lack of a DC-link. The proposed control strategy and modulation schemes ensure the sinusoidal input and output waveforms and bidirectional power transmission. The proposed system for the HEV application is verified by simulation and experiments.

  19. A three-phase to three-phase series-resonant power converter with optimal input current waveforms, Part I: control strategy

    NARCIS (Netherlands)

    Huisman, H.

    1988-01-01

    A control strategy for multiphase-input multiphase-output AC to AC series-resonant (SR) power converters is presented. After reviewing some basics in SR power converters, a hierarchy of control mechanisms is presented, together with their respective theoretical backgrounds and practical limitations.

  20. Carrier-based modulation schemes for various three-level matrix converters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, P.C.; Rong, R.C.

    2008-01-01

    different performance merits. To avoid confusion and hence fasten the converter applications in the industry, it would surely be better for modulation schemes to be developed from a common set of modulation principles that unfortunately has not yet been thoroughly defined. Contributing to that area...... a limited set of switching vectors because of its lower semiconductor count. Through simulation and experimental testing, all the evaluated matrix converters are shown to produce satisfactory sinusoidal input and output quantities using the same set of generic modulation principles, which can conveniently...

  1. A ZVS PWM control strategy with balanced capacitor current for half-bridge three-level DC/DC converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2017-01-01

    The capacitor current would be imbalanced under the conventional control strategy in the half-bridge three-level (HBTL) DC/DC converter due to the effect of the output inductance of the power supply and the input line inductance, which would affect the converter's reliability. This paper proposes...... a pulse-wide modulation (PWM) strategy composed of two operation modes for the HBTL DC/DC converter, which can realize the zero-voltage switching (ZVS) for the efficiency improvement. In addition, a capacitor current balancing control is proposed by alternating the two operation modes of the proposed ZVS...... PWM strategy, which can eliminate the current imbalance among the two input capacitors. Therefore, the proposed control strategy can improve the converter's performance and reliability in: 1) reducing the switching losses and noises of the power switches; 2) balancing the thermal stresses...

  2. Design of six pulse bridge multiplication converter model for current harmonic elimination of three phase ac-dc converter

    International Nuclear Information System (INIS)

    Soomro, M.A.; Helepoto, I.A.

    2014-01-01

    The recent development of semiconductor technology and wide spread use of power electronic devices in power system have open the era of the power system harmonics due to increasing penetration of non-linear loads. Harmonics are widely admitted as most important issues of power quality which must be eliminated to maintain power system reliability. The tolerable THD (Total Harmonic Distortion) values must be bounded in well-defined limits recognized by IEEE-519 standard. In this work, in order to eliminate the current harmonics produced by non-linear loads, six pulse multiplication converter technique in conjunction with STSSHPE (Single Tuned Shunt Harmonic Passive Filter) is proposed. The proposed model has the capacity of harmonic cancellation of the dominant 3rd order harmonics. Besides that, the 5th and 7th order harmonics are also reduced to a diminishing level. The hardware model has been experimentally tested by PQA (Power Quality Analyzer) and simulation model is designed using MATLAB software. The acquired results have been measured by considering THD values in terms of current and voltage. Furthermore, they have been compared against IEEE-519 performance standards. The prosed model, successfully bounds the total harmonic distortion under defined limits by IEEE-519 standard. (author)

  3. A nonlinear adaptive backstepping approach applied to a three phase PWM AC-DC converter feeding induction heating

    Science.gov (United States)

    Hadri-Hamida, A.; Allag, A.; Hammoudi, M. Y.; Mimoune, S. M.; Zerouali, S.; Ayad, M. Y.; Becherif, M.; Miliani, E.; Miraoui, A.

    2009-04-01

    This paper presents a new control strategy for a three phase PWM converter, which consists of applying an adaptive nonlinear control. The input-output feedback linearization approach is based on the exact cancellation of the nonlinearity, for this reason, this technique is not efficient, because system parameters can vary. First a nonlinear system modelling is derived with state variables of the input current and the output voltage by using power balance of the input and output, the nonlinear adaptive backstepping control can compensate the nonlinearities in the nominal system and the uncertainties. Simulation results are obtained using Matlab/Simulink. These results show how the adaptive backstepping law updates the system parameters and provide an efficient control design both for tracking and regulation in order to improve the power factor.

  4. Periodically Swapping Modulation (PSM) Strategy for Three-Level (TL) DC/DC Converter with Balanced Switch Currents

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Zhang, Qi

    2018-01-01

    The asymmetrical modulation strategy is widely used in various types of three-level (TL) DC/DC converters, while the current imbalance among the power switches is one of the important issues. In this paper, a novel periodically swapping modulation (PSM) strategy is proposed for balancing the power...... switches’ currents in various types of TL DC/DC converters. In the proposed PSM strategy, the driving signals of the switch pairs are swapped periodically, which guarantees that the currents through the power switches are kept balanced in every two switching periods. Therefore, the proposed PSM...... strategy can effectively improve the reliability of the converter by balancing the power losses and thermal stresses among the power switches. The operation principle and performances of the proposed PSM strategy are analyzed in detail. Finally, the simulation and experimental results are presented...

  5. A High-Frequency Isolation (HFI Charging DC Port Combining a Front-End Three-Level Converter with a Back-End LLC Resonant Converter

    Directory of Open Access Journals (Sweden)

    Guowei Cai

    2017-09-01

    Full Text Available The high-frequency isolation (HFI charging DC port can serve as the interface between unipolar/bipolar DC buses and electric vehicles (EVs through the two-power-stage system structure that combines the front-end three-level converter with the back-end logical link control (LLC resonant converter. The DC output voltage can be maintained within the desired voltage range by the front-end converter. The electrical isolation can be realized by the back-end LLC converter, which has the bus converter function. According to the three-level topology, the low-voltage rating power devices can be adapted for half-voltage stress of the total DC grid, and the PWM phase-shift control can double the equivalent switching frequency to greatly reduce the filter volume. LLC resonant converters have advance characteristics of inverter-side zero-voltage-switching (ZVS and rectifier-side zero-current switching (ZCS. In particular, it can achieve better performance under quasi-resonant frequency mode. Additionally, the magnetizing current can be modified following different DC output voltages, which have the self-adaptation ZVS condition for decreasing the circulating current. Here, the principles of the proposed topology are analyzed in detail, and the design conditions of the three-level output filter and high-frequency isolation transformer are explored. Finally, a 20 kW prototype with the 760 V input and 200–500 V output are designed and tested. The experimental results are demonstrated to verify the validity and performance of this charging DC port system structure.

  6. Three-phase electronic power converter for photovoltaic system connected to power line; Conversor eletronico de potencia trifasico para sistema fotovoltaico conectado a rede eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Villalva, Marcelo Gradella

    2010-10-15

    This work is a contribution to the study of power converters for photovoltaic distributed generation systems. The main objective is to present the development and results of a three phase power converter for a grid-connected photovoltaic plant. The work presents experimental results and theoretical studies on the modeling and simulation of photovoltaic devices, regulation of the photovoltaic voltage, maximum power point tracking, and the modeling and control of a two-stage grid-connected power converter. (author)

  7. Input-Parallel Output-Parallel Three-Level DC/DC Converters With Interleaving Control Strategy for Minimizing and Balancing Capacitor Ripple Currents

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Gong, Zheng

    2017-01-01

    In this paper, the input-parallel output-parallel (IPOP) three-level (TL) DC/DC converters associated with the interleaving control strategy are proposed for minimizing and balancing the capacitor ripple currents. The proposed converters consist of two four-switch half-bridge three-level (HBTL) DC...

  8. Small-Signal Analysis of Single-Phase and Three-phase DC/AC and AC/DC PWM Converters with the Frequency-Shift Technique

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Aquila, A. Dell’; Liserre, Marco

    2004-01-01

    of dc/dc converters via a 50 Hz frequency-shift. The input admittance is calculated and measured for two study examples (a three-phase active rectifier and a single-phase photovoltaic inverter). These examples show that the purpose of a well designed controller for grid-connected converters......A systematic approach to study dc/ac and ac/dc converters without the use of synchronous transformation is proposed. The use of a frequency-shift technique allows a straightforward analysis of single-phase and three-phase systems. The study of dc/ac and of ac/dc converters is reported to the study...... is to minimize the input admittance in order to make the grid converter more robust to grid disturbance....

  9. Multiple low frequency dual reference PWM control of a grid connected photovoltaic three phase NPC inverter with DC/DC boost converter

    Directory of Open Access Journals (Sweden)

    Mechouma Rabiaa

    2014-01-01

    Full Text Available In recent years, power demand of industrial applications has increased significantly reaching some megawatts. The use of multilevel converters for applications of medium and high powers is proposed as a solution to drawback semiconductor technology. A multilevel converter not only achieves high power ratings, but also enables the use of renewable energy sources. Renewable energy sources such as photovoltaic can be easily interfaced to a multilevel converter system for a high power application. This paper presents the simulation study in Matlab/Simulink of a grid connected photovoltaic three phase Neutral Point Clamped (NPC inverter with DC/DC boost converter for constant and variable solar radiation.

  10. Comparison of soft and hard-switching effiency in a three-level single phase 60kW dc-ac converter

    DEFF Research Database (Denmark)

    Munk-Nielsen, Stig; Teodorescu, Remus; Bech, Michael Møller

    2003-01-01

    Efficiency measurements on a three-level single-phase soft-switched converter are presented and show a slightly improved efficiency compared with the hard-switched converter for output powers higher than 25 % of rated power. The resonant converter switches are Zero Voltage Switched (ZVS......) and a simple resonant circuit is used. Increased resonant converter efficiency enables a reduction in the semiconductor size pr. watt output power or an increase the switching frequency....

  11. Pulse Pattern-Modulated Strategy for Harmonic Current Components Reduction in Three-Phase AC–DC Converters

    DEFF Research Database (Denmark)

    Davari, Pooya; Zare, Firuz; Blaabjerg, Frede

    2016-01-01

    , which need to be considered in order to be competitive in the market. Therefore, having a flexibility to meet various requirements imposed by the standard recommendations or costumer needs is at most desirable. This makes the generated harmonic current mitigation a challenging task especially with three......-phase diode bridge rectifier, which still is preferred in many power electronic systems. This paper addresses a novel current modulation strategy using a single-switch boost three-phase diode bridge rectifier. The proposed method can selectively mitigate current harmonics, which makes it suitable...

  12. Pulse pattern modulated strategy for harmonic current components reduction in three-phase AC-DC converters

    DEFF Research Database (Denmark)

    Davari, Pooya; Zare, Firuz; Blaabjerg, Frede

    2015-01-01

    , which need to be considered in order to be competitive in the market. Therefore, having a flexibility to meet various requirements imposed by the standard recommendations or costumer needs is at most desirable. This makes the generated harmonic current mitigation a challenging task especially with three......-phase diode bridge rectifier, which still is preferred in many power electronic systems. This paper addresses a novel current modulation strategy using a single-switch boost three-phase diode bridge rectifier. The proposed method can selectively mitigate current harmonics, which makes it suitable...

  13. Control of a Vanadium Redox Battery and supercapacitor using a Three-Level Neutral Point Clamped converter

    Science.gov (United States)

    Etxeberria, A.; Vechiu, I.; Baudoin, S.; Camblong, H.; Kreckelbergh, S.

    2014-02-01

    The increasing use of distributed generators, which are mainly based on renewable sources, can create several issues in the operation of the electric grid. The microgrid is being analysed as a solution to the integration in the grid of the renewable sources at a high penetration level in a controlled way. The storage systems play a vital role in order to keep the energy and power balance of the microgrid. Due to the technical limitations of the currently available storage systems, it is necessary to use more than one storage technology to satisfy the requirements of the microgrid application. This work validates in simulations and experimentally the use of a Three-Level Neutral Point Clamped converter to control the power flow of a hybrid storage system formed by a SuperCapacitor and a Vanadium Redox Battery. The operation of the system is validated in two case studies in the experimental platform installed in ESTIA. The experimental results prove the validity of the proposed system as well as the designed control algorithm. The good agreement among experimental and simulation results also validates the simulation model, that can therefore be used to analyse the operation of the system in different case studies.

  14. Converter Structure-Based Power Loss and Static Thermal Modeling of The Press-Pack IGBT Three-Level ANPC VSC Applied to Multi-MW Wind Turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2011-01-01

    performance, the converter structure-based power loss and thermal models are developed in this study for the medium-voltage (MV) three-level active neutral-point-clamped voltage source converter (3L-ANPC-VSC) utilizing 4500 V-1800 A press-pack insulated-gate bipolar transistor-diode pairs and interfacing a 6...

  15. A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters

    DEFF Research Database (Denmark)

    Beres, Remus Narcis; Wang, Xiongfei; Liserre, Marco

    2016-01-01

    and source impedances. Furthermore, the stabilizing effect is more difficult to be guaranteed for cost-optimized filters, which are characterized by low inductance and high capacitance passive components. In this paper, several passive filter topologies used to interface voltage source converters......In order to reduce size and cost, high-order passive filters are generally preferred in power converters to cancel out high frequency harmonics caused by pulse width modulation. However, the filter resonance peaks may require the use of passive dampers to stabilize the interactions between the load...

  16. Systematic Design of the Lead-Lag Network Method for Active Damping in LCL-Filter Based Three Phase Converters

    DEFF Research Database (Denmark)

    Alzola, Rafael Pena; Liserre, Marco; Blaabjerg, Frede

    2014-01-01

    ) nor its rationale has been explained. Thus, in this paper a straightforward procedure is developed to tune the lead-lag network with the help of software tools. The rationale of this procedure, based on the capacitor current feedback, is elucidated. Stability is studied by means of the root locus......Three-phase active rectifiers guarantee sinusoidal input currents and unity power factor at the price of a high switching frequency ripple. To adopt an LCL-filter, instead of an L-filter, allows using reduced values for the inductances and so preserving dynamics. However, stability problems can...... without using dissipative elements but, sometimes, needing additional sensors. This solution has been addressed in many publications. The lead-lag network method is one of the first reported procedures and continues being in use. However, neither there is a direct tuning procedure (without trial and error...

  17. Input-parallel output-parallel (IPOP) three-level (TL) DC/DC converters with minimized capacitor ripple currents

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Zhang, Qi

    2016-01-01

    , the component current stresses in the proposed converters are reduced. More significantly, the combination of the proposed IPOP TL circuit structure and the interleaving control strategy can largely reduce the ripple currents on the two input capacitors not only by doubling the frequencies of the ripple...... currents on two input capacitors but also by counteracting part of these ripple currents according to the operation principle of the proposed converters. Therefore, the proposed IPOP TL DC/DC converters with the interleaving control strategy can improve the performances of the converters in increasing...... the lifetimes of the input capacitors and minimizing the sizes of the input capacitors. Finally, the simulation and experimental results are presented to verify the effectiveness and feasibility of the proposed converters combined with the interleaving control strategy....

  18. Single-phase to three-phase converter system of high quality for rural applications and distributed generation; Sistema conversor mono-trifasico de alta qualidade para aplicacoes rurais e de geracao distribuida

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Ricardo Q.; Pomilio, Jose A. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. de Engenharia Eletrica e de Computacao], e-mail: ricardom@dsce.fee.unicamp.br; Buso, Simone [Universidade de Padova, Padua (Italy). Dept. de Engenharia da Informacao], e-mail: simone.buso@dei.unipd.it

    2004-07-01

    This paper describes a line-interactive single-phase to three-phase converter. The typical application is in rural areas supplied by the single-wire with earth return. The traditional objective of feeding a three-phase induction motor is not anymore the main concern for such conversion. Due to the evolution of the agro business, some of the local load (as electronic power converters, computers, communication equipment, etc.) requires high quality power, intended as sinusoidal, symmetrical and balanced three-phase voltage. Additionally, to maximize the power got from the feeder, the system provides a unitary power factor to the feeder. A three-phase PWM converter is used for this purpose. The power converter does not process all the load power, as in the conventional solutions, but only the fraction necessary to regulate the three-phase bus voltage. The control strategy, design highlights and experimental results are presented. (author)

  19. Application of the Min-Projection and the Model Predictive Strategies for Current Control of Three-Phase Grid-Connected Converters: a Comparative Study

    Directory of Open Access Journals (Sweden)

    M. Oloumi

    2015-06-01

    Full Text Available This paper provides a detailed comparative study concerning the performance of min-projection strategy (MPS and model predictive control (MPC systems to control the three-phase grid connected converters. To do so, first, the converter is modeled as a switched linear system. Then, the feasibility of the MPS technique is investigated and its stability criterion is derived as a lower limit on the DC link voltage. Next, the fundamental equations of the MPS to control a VSC are obtained in the stationary reference frame. The mathematical analysis reveals that the MPS is independent of the load, grid, filter and converter parameters. This feature is a great advantage of MPS over the MPC approach. However, the latter is a well-known model-based control technique, has already developed for controlling the VSC in the stationary reference frame. To control the grid connected VSC, both MPS and MPC approaches are simulated in the PSCAD/EMTDC environment. Simulation results illustrate that the MPS is functioning well and is less sensitive to grid and filter inductances as well as the DC link voltage level. However, the MPC approach renders slightly a better performance in the steady state conditions.

  20. A Zero-Voltage Switching Control Strategy for Dual Half-Bridge Cascaded Three-Level DC/DC Converter with Balanced Capacitor Voltages

    DEFF Research Database (Denmark)

    Liu, Dong; Wang, Yanbo; Chen, Zhe

    2017-01-01

    The input capacitor's voltages are unbalanced under the conventional control strategy in a dual half-bridge cascaded three-level (TL) DC/DC converter, which would affect the high voltage stresses on the capacitors. This paper proposes a pulse-wide modulation (PWM) strategy with two working modes...... for the dual half-bridge cascaded TL DC/DC converter, which can realize the zero-voltage switching (ZVS). More significantly, a capacitor voltage balance control is proposed by alternating the two working modes of the proposed ZVS PWM strategy, which can eliminate the voltage unbalance on the four input...... capacitors. Therefore, the proposed control strategy can improve the converter's performances in: 1) reducing the switching losses and noises of the power switches; and 2) reducing the voltage stresses on the input capacitors. Finally, the simulation results are conducted to verify the proposed control...

  1. Back-to-back three-level converter controlled by a novel space-vector hysteresis current control for wind conversion systems

    Energy Technology Data Exchange (ETDEWEB)

    Ghennam, Tarak [Laboratoire d' Electronique de Puissance (LEP), UER: Electrotechnique, Ecole Militaire Polytechnique d' Alger, BP 17, Bordj EL Bahri, Alger (Algeria); Berkouk, El-Madjid [Laboratoire de Commande des Processus (LCP), Ecole Nationale Polytechnique d' Alger, BP 182, 10 avenue Hassen Badi, 16200 el Harrach (Algeria)

    2010-04-15

    In this paper, a novel space-vector hysteresis current control (SVHCC) is proposed for a back-to-back three-level converter which is used as an electronic interface in a wind conversion system. The proposed SVHCC controls the active and reactive powers delivered to the grid by the doubly fed induction machine (DFIM) through the control of its rotor currents. In addition, it controls the neutral point voltage by using the redundant inverter switching states. The three rotor current errors are gathered into a single space-vector quantity. The magnitude of the error vector is limited within boundary areas of a square shape. The control scheme is based firstly on the detection of the area and sector in which the vector tip of the current error can be located. Then, an appropriate voltage vector among the 27 voltage vectors of the three-level voltage source inverter (VSI) is applied to push the error vector towards the hysteresis boundaries. Simple look-up tables are required for the area and sector detection, and also for vector selection. The performance of the proposed control technique has been verified by simulations. (author)

  2. Inductor Design Comparison of Three-wire and Four-wire Three-phase Voltage Source Converters in Power Factor Correction Applications

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2015-01-01

    This paper studies the inductor design for three-wire and four-wire power factor correction converter (PFC). Designing the efficient inductor for this converter (regardless of connecting the midpoint to the ground) requires a comprehensive knowledge of the inductor current and voltage behavior....... This paper investigates how changing three-wire PFC to four-wire counterpart influences the inductor design in terms of size, losses, and overall efficiency of the converter. Therefore, the inductor current and voltage waveforms are analyzed and generalized in both cases for one switching cycle to build...... a foundation for comparison. Accordingly, the analyses are able to interpret the differences between both configurations and explain the core losses and the copper losses of inductors, especially those caused by the high frequency ac current ripple. Finally, two inductors are designed for a 5 kW PFC...

  3. A Self-commissioning Notch Filter for Active Damping in a Three-Phase LCL -Filter-Based Grid-Tie Converter

    DEFF Research Database (Denmark)

    Pena-Alzola, Rafael; Liserre, Marco; Blaabjerg, Frede

    2014-01-01

    LCL-filters are a cost-effective solution to mitigate harmonic current content in grid-tie converters. In order to avoid stability problems, the resonance frequency of LCL-filters can be damped with active techniques that remove dissipative elements but increase control complexity. A notch filter...

  4. High power factor, fixed frequency, three-phase AC/CC converter which uses a single power processing stage; Conversor CA/CC, trifasico, com alto fator de potencia, frequencia fixa, empregando um unico estagio de processamento de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Davila, Jose Gregorio Contreras

    1993-11-01

    This paper introduces a new switching mode power supply with the following properties: zero-voltage switching, pulse-width modulation at constant frequency, three-phase input with power factor and low input current distortion, using a simple power stage. The converter is designed in a manner that the input current harmonic content is reduced naturally. Circuit-operation, theoretical analysis, simulation, design procedure and example are presented. A laboratory prototype rated at 3 kW and operating at 100 Khz, has been fabricated and tested successfully. (author) 15 refs., 75 figs.

  5. High-performance control of a three-phase voltage-source converter including feedforward compensation of the estimated load current

    International Nuclear Information System (INIS)

    Leon, Andres E.; Solsona, Jorge A.; Busada, Claudio; Chiacchiarini, Hector; Valla, Maria Ines

    2009-01-01

    In this paper a new control strategy for voltage-source converters (VSC) is introduced. The proposed strategy consists of a nonlinear feedback controller based on feedback linearization plus a feedforward compensation of the estimated load current. In our proposal an energy function and the direct-axis current are considered as outputs, in order to avoid the internal dynamics. In this way, a full linearization is obtained via nonlinear transformation and feedback. An estimate of the load current is feedforwarded to improve the performance of the whole system and to diminish the capacitor size. This estimation allows to obtain a more rugged and cheaper implementation. The estimate is calculated by using a nonlinear reduced-order observer. The proposal is validated through different tests. These tests include performance in presence of switching frequency, measurement filters delays, parameters uncertainties and disturbances in the input voltage.

  6. Neutral-point current modeling and control for Neutral-Point Clamped three-level converter drive with small DC-link capacitors

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, Sergio

    2011-01-01

    A Neutral-Point-Clamped (NPC) three-level inverter with small DC-link capacitors is presented in this paper. This inverter requires zero average neutral-point current for stable neutral-point potential. A simple carrier based modulation strategy is proposed for achieving zero average neutral...... drive with only 14 μF DC-link capacitors. A fast and stable performance of the neutral-point voltage controller is achieved and verified by experiments....

  7. Zero-Voltage Switching PWM Strategy Based Capacitor Current-Balancing Control for Half-Bridge Three-Level DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Zhang, Qi

    2018-01-01

    The current imbalance among the two input capacitors is one of the important issues of the half-bridge threelevel (HBTL) DC/DC converter, which would affect system performance and reliability. In this paper, a zero-voltage switching (ZVS) pulse-wide modulation (PWM) strategy including two operation...

  8. Loss Distribution Analysis of Three-Level Active Neutral-Point-Clamped (3L-ANPC) Converter with Different PWM Strategies

    DEFF Research Database (Denmark)

    Zhang, Gang; Yang, Yongheng; Iannuzzo, Francesco

    2016-01-01

    The three-level (3L) Active Neutral-Point-Clamped (ANPC) topology has been introduced to resolve the uneven loss distribution issue in the classical 3L Neutral-Point-Clamped (NPC) topology. This Pulse-Width-Modulation (PWM) strategy is then an important means to fully explore the potential benefits...... are separated in order to improve the loss distribution among the power devices. A comparison between the proposed strategy and other major PWM strategies for the loss distribution is also carried out in this paper. Benchmarking results show that the proposed strategy has effective and superior performance...

  9. Three-phase Photovoltaic Systems

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Máthé, Lászlo

    2015-01-01

    , detailing the different photovoltaic inverter structures and topologies as well as discussing the different control layers within a grid-connected photovoltaic plant. Modulation schemes for various photovoltaic inverter topologies, grid synchronization, current control, active and reactive power control......Photovoltaic technology has experienced unprecedented growth in the last two decades, transforming from mainly off-grid niche generation to a major renewable energy technology, reaching approximately 180 GW of capacity worldwide at the end of 2014. Large photovoltaic power plants interfacing...... the grid through a three-phase power electronic converter are now well on the way to becoming a major player in the power system in many countries. Therefore, this article gives an overview of photovoltaic systems with a focus on three-phase applications, presenting these both from a hardware point of view...

  10. Performance Analysis of a Four-Switch Three-Phase Grid-Side Converter with Modulation Simplification in a Doubly-Fed Induction Generator-Based Wind Turbine (DFIG-WT with Different External Disturbances

    Directory of Open Access Journals (Sweden)

    Kai Ni

    2017-05-01

    Full Text Available This paper investigates the performance of a fault-tolerant four-switch three-phase (FSTP grid-side converter (GSC in a doubly-fed induction generator-based wind turbine (DFIG-WT. The space vector pulse width modulation (SVPWM technique is simplified and unified duty ratios are used for controlling the FSTP GSC. Steady DC-bus voltage, sinusoidal three-phase grid currents and unity power factor are obtained. In addition, the balance of capacitor voltages is accomplished based on the analysis of current flows at the midpoint of DC bus in different operational modes. Besides, external disturbances such as fluctuating wind speed and grid voltage sag are considered to test its fault-tolerant ability. Furthermore, the effects of fluctuating wind speed on the performance of DFIG-WT system are explained according to an approximate expression of the turbine torque. The performance of the proposed FSTP GSC is simulated in Matlab/Simulink 2016a based on a detailed 1.5 MW DFIG-WT Simulink model. Experiments are carried out on a 2 kW platform by using a discrete signal processor (DSP TMS320F28335 controller to validate the reliability of DFIG-WT for the cases with step change of the stator active power and grid voltage sag, respectively.

  11. A Controller For The Three-phase To Three-phase Matrix Converter And For The Voltage Source Three-phase Inverter Without Dc-link Capacitor [um Controlador De Corrente De Carga Para O Conversor Em Matriz Trifásico Para Trifásico E Para O Inversor De Frequência Sem Capacitor Do Elo De Corrente Contínua

    OpenAIRE

    Filho M.E.O.; Gazoli J.R.; Filho A.J.S.; Ruppert E.

    2010-01-01

    Voltage source three-phase inverter plays an important role in modern industry. The conventional voltage source inverter has a large electrolytic capacitor as energy store element in order to keep the DC-link voltage constant. However, a large electrolytic capacitor increases the input current distortion. Replacing the large electrolytic capacitor by a small film capacitor, the input current quality is improved but the DC-link voltage and the output currents are distorted by low order harmoni...

  12. Fault-tolerant three-level inverter

    Science.gov (United States)

    Edwards, John; Xu, Longya; Bhargava, Brij B.

    2006-12-05

    A method for driving a neutral point clamped three-level inverter is provided. In one exemplary embodiment, DC current is received at a neutral point-clamped three-level inverter. The inverter has a plurality of nodes including first, second and third output nodes. The inverter also has a plurality of switches. Faults are checked for in the inverter and predetermined switches are automatically activated responsive to a detected fault such that three-phase electrical power is provided at the output nodes.

  13. Three Levels of Semiosis

    DEFF Research Database (Denmark)

    Alrøe, Hugo Fjelsted

    2016-01-01

    This paper presents a second-order semiotic framework for ontological levels, which is based on the structure of semiosis in a more fundamental way than other existing approaches to semiotic levels. Building on the key semiotic concept of representation, three levels are posited: (1) non- or proto......-semiotic processes, without representation, such as physical or causal processes, (2) semiotic processes, with representation, such as the processes of life and cognition, and (3) second-order semiotic processes, with representation of representation, such as self-conscious and self-reflexive communicative processes....... This semiotic framework for ontological levels is compared with recent discussions of different ontological kinds of kinds such as indifferent and interactive kinds. This leads to the distinction between not two, but three kinds of kinds: indifferent, adaptive and reflexive kinds, of which the last two hitherto...

  14. Converter structure-based power loss and static thermal modeling of the press-pack IGBT-based three-level ANPC and HB VSCs applied to Multi-MW wind turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Munk-Nielsen, Stig; Teodorescu, Remus

    2010-01-01

    and the switch thermal performance which is determined by the converter load profile and the converter structure. In this study, the converter-structure based power loss and thermal models are developed for the medium voltage full-scale 3LANPC- VSC and 3L-HB-VSC utilizing press-pack IGBT-diode pairs......The wind turbine converters demand high power density due to nacelle space limitation and high reliability due to high maintenance cost. Once the converter topology with the semiconductor switch technology is selected, the converter power density and reliability are dependent on the component count...

  15. Sine-wave three phase resonance inverter for operation of ...

    African Journals Online (AJOL)

    This paper proposes a high performance single-stage three phase inverter topology for the autonomous operation of renewable energy systems. The proposed configuration can boost the low voltage of renewable energy systems such as photo voltaic systems, fuel cells, and etc can also convert the output dc power, into ...

  16. Research on three-phase unbalanced distribution network reconfiguration strategy

    Science.gov (United States)

    Hu, Shuang; Li, Ke-Jun; Xu, Yanshun; Liu, Zhijie; Guo, Jing; Wang, Zhuodi

    2017-01-01

    With the development of social economy, the loads installed in the distribution network become more and more complex which may cause the three-phase unbalance problems. This paper proposes an optimal reconfiguration approach based on mixed integer quadric programming (MIQP) method to address the three-phase unbalance problem. It aims to minimize the total network losses of the system. By using several square constraints to substitute the circular constraint, the original optimization problem is linearized and converted into a mixed-integer linear programming (MILP) model. Then this MILP problem is solved in general algebraic model system (GAMS) software using CPLEX solver. The additional losses caused by three-phase unbalanced are also considered. An IEEE 34 nodes test system is used to demonstrate the feasibility and effectiveness of the proposed method. The results show that the losses and the voltage violation mitigation in the network can be reduced significantly.

  17. Three level MV converter using series connected IGBT's

    DEFF Research Database (Denmark)

    Munk-Nielsen, Stig; Vaerens, M.C.P.; Sundvall, J.

    2009-01-01

    A simple method of serial connecting IGBT's is applied and standard low voltage IGBT modules are used in the MV test inverter to evaluate the method. The dc link voltage is 2.4 kV and the RMS output line to line voltage is 1.7kV. The method works and test experiences are presented in paper....

  18. Speed-controlled three-phase drives. Drehzahlgeregelte Drehstromantriebe

    Energy Technology Data Exchange (ETDEWEB)

    Steinmetz, E

    1981-01-01

    Present semiconductor circuit elements have made it possible to produce frequency converters for speed-controlled three-phase drives from the k'' range to the MW range at low cost. Line-powered frequency converter circuits are already in the standardisation stage while the development trends in the field of speed-controlled frequency converter circuits are not foreseeable as yet. Recent developments in the field of electronics have made the circuits simpler and able to implement an increasing number of functions. There is a trend towards programmable digital control systems with microcomputers. Of the 8 articles in the publication, the contribution by M. Wild and R. Wetzl (Synchronous motors with frequency converters drive boiler feed pumps at Bergkamen power plant) has been entered in the data base as a separate citation.

  19. Single stage three level grid interactive MPPT inverter for PV systems

    International Nuclear Information System (INIS)

    Ozdemir, Saban; Altin, Necmi; Sefa, Ibrahim

    2014-01-01

    Highlights: • A three phase three-level NPC inverter for grid interactive PV systems is proposed. • A novel MPPT algorithm is introduced for single stage systems. • The proposed algorithm is robust with respect to parameter variations of PV system. • THD level is measured as 3.45% and it meets the international standards (<5%). • Total system efficiency is measured as 93.08%. - Abstract: In this study, three-phase, single stage neutral point clamped grid interactive inverter is designed and implemented. The reference current of the voltage source inverter is determined by maximum power point tracking sub-program in order to obtain maximum power from photovoltaic modules instantaneously. Proposed control is realized via TMS320F28335 32-bit floating point processor. The modified incremental conductance method is applied for maximum power point tracking; the PI regulator is used to control the inverter output current shape and level. Galvanic isolation is provided by a line frequency transformer that matches inverter output voltage to the grid voltage level and prevents DC current injection into the grid. Experimental results show that the designed inverter imports energy to the grid with unity power factor, total harmonic distortion level is 3.45% and this value is in the limits of the international standards. In addition, the total efficiency of the system is measured as 93.08%. The proposed system gets the maximum power from photovoltaic module and dispatches into the grid without using additional DC/DC converter

  20. Three-Phased Wake Vortex Decay

    Science.gov (United States)

    Proctor, Fred H.; Ahmad, Nashat N.; Switzer, George S.; LimonDuparcmeur, Fanny M.

    2010-01-01

    A detailed parametric study is conducted that examines vortex decay within turbulent and stratified atmospheres. The study uses a large eddy simulation model to simulate the out-of-ground effect behavior of wake vortices due to their interaction with atmospheric turbulence and thermal stratification. This paper presents results from a parametric investigation and suggests improvements for existing fast-time wake prediction models. This paper also describes a three-phased decay for wake vortices. The third phase is characterized by a relatively slow rate of circulation decay, and is associated with the ringvortex stage that occurs following vortex linking. The three-phased decay is most prevalent for wakes imbedded within environments having low-turbulence and near-neutral stratification.

  1. Three phase full wave dc motor decoder

    Science.gov (United States)

    Studer, P. A. (Inventor)

    1977-01-01

    A three phase decoder for dc motors is disclosed which employs an extremely simple six transistor circuit to derive six properly phased output signals for fullwave operation of dc motors. Six decoding transistors are coupled at their base-emitter junctions across a resistor network arranged in a delta configuration. Each point of the delta configuration is coupled to one of three position sensors which sense the rotational position of the motor. A second embodiment of the invention is disclosed in which photo-optical isolators are used in place of the decoding transistors.

  2. Realization of station for testing asynchronous three-phase motors

    Science.gov (United States)

    Wróbel, A.; Surma, W.

    2016-08-01

    Nowadays, you cannot imagine the construction and operation of machines without the use of electric motors [13-15]. The proposed position is designed to allow testing of asynchronous three-phase motors. The position consists of a tested engine and the engine running as a load, both engines combined with a mechanical clutch [2]. The value of the load is recorded by measuring shaft created with Strain Gauge Bridge. This concept will allow to study the basic parameters of the engines, visualization motor parameters both vector and scalar controlled, during varying load drive system. In addition, registration during the variable physical parameters of the working electric motor, controlled by a frequency converter or controlled by a contactor will be possible. Position is designed as a teaching and research position to characterize the engines. It will be also possible selection of inverter parameters.

  3. A Novel Three Phase to Seven Phase Conversion Technique Using Transformer Winding Connections

    Directory of Open Access Journals (Sweden)

    M. Tabrez

    2017-10-01

    Full Text Available This paper proposes a novel multiphase transformer connection scheme which converts three phase balanced AC input to seven phase balanced AC output. Generalized theory to convert a three phase utility supply into any number of phases is presented. Based on the proposed generalized principle, a three phase to seven phase power converting transformer design is presented with connection scheme, analysis and simulation and experimental results of the proposed three phase to seven phase conversion transformer. The proposed transformer in this paper is analyzed and compared with the connection scheme for seven phase available in the literature. The connection scheme is found to have higher power density, lower core area and lower core requirement as compared to the available connection scheme of the same rating. Impedance mismatching between different phases of the transformer is observed in the three phase to seven phase transformer available in the literature. As this mismatching introduces error in study of per phase equivalent circuit diagrams as well as imbalance in voltage and currents. The present design also addresses the impedance mismatching issue and reduces mismatching in the proposed transformer design. A prototype of the proposed system is developed and waveforms are presented. The proposed design is verified using simulation and validated using experimental approach.

  4. Novel, Four-Switch, Z-Source Three-Phase Inverter

    DEFF Research Database (Denmark)

    Antal, Robert; Muntean, Nicolae; Boldea, Ion

    2010-01-01

    This paper presents a new z-source three phase inverter topology. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with the advantages of the z impedance network (one front-end diode, two inductors and two X connected capacitors). This new topology......, besides the self-boost property, has low switch count and it can operate as a buck-boost inverter. In contrast to standard four-switch three-phase inverter which operates at half dc input voltage the proposed four-switch z-source inverter, by self boosting, brings the output voltage at same (or higher......) value as in six switch standard three-phase inverter. The article presents the derivation of the equations describing the operation of the converter based on space vector analysis, validation through digital simulations in PSIM and preliminary experimental results on a laboratory setup with a dsPIC30F...

  5. A low cost rapid prototype platform for a three phase PFC rectifier application

    DEFF Research Database (Denmark)

    Haase, Frerk; Kouchaki, Alireza; Nymand, Morten

    2015-01-01

    In this paper the design and development of a low cost rapid prototype platform for a Three Phase PFC rectifier application is presented. The active rectifier consists of a SiC-MOSFET based PWM converter and a low cost rapid prototype platform for simulating and implementing the digital control...

  6. The three phases of galaxy formation

    Science.gov (United States)

    Clauwens, Bart; Schaye, Joop; Franx, Marijn; Bower, Richard G.

    2018-05-01

    We investigate the origin of the Hubble sequence by analysing the evolution of the kinematic morphologies of central galaxies in the EAGLE cosmological simulation. By separating each galaxy into disc and spheroidal stellar components and tracing their evolution along the merger tree, we find that the morphology of galaxies follows a common evolutionary trend. We distinguish three phases of galaxy formation. These phases are determined primarily by mass, rather than redshift. For M* ≲ 109.5M⊙ galaxies grow in a disorganised way, resulting in a morphology that is dominated by random stellar motions. This phase is dominated by in-situ star formation, partly triggered by mergers. In the mass range 109.5M⊙ ≲ M* ≲ 1010.5M⊙ galaxies evolve towards a disc-dominated morphology, driven by in-situ star formation. The central spheroid (i.e. the bulge) at z = 0 consists mostly of stars that formed in-situ, yet the formation of the bulge is to a large degree associated with mergers. Finally, at M* ≳ 1010.5M⊙ growth through in-situ star formation slows down considerably and galaxies transform towards a more spheroidal morphology. This transformation is driven more by the buildup of spheroids than by the destruction of discs. Spheroid formation in these galaxies happens mostly by accretion at large radii of stars formed ex-situ (i.e. the halo rather than the bulge).

  7. Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

    Science.gov (United States)

    Afiqah Zainal, Nurul; Sooi Tat, Chan; Ajisman

    2016-02-01

    Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's ou tput is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor.

  8. Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

    International Nuclear Information System (INIS)

    Zainal, Nurul Afiqah; Tat, Chan Sooi; Ajisman

    2016-01-01

    Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's output is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor. (paper)

  9. A novel proposal of cooperation between a cage induction generator and the three-phase grid

    Directory of Open Access Journals (Sweden)

    Szular Zbigniew

    2016-01-01

    Full Text Available In the paper, a new concept of the cooperation between a cage induction generator and the three-phase grid is presented. The induction generator is excited by a capacitor battery connected to the stator winding terminals. In order to ensure a stable operation, the battery capacity should be continuously adjusted. Three appropriate selected capacitors are connected to the stator winding terminals by means of two bi-directional controlled switches. The generator output voltage is stabilized by a suitable control of these switches. The stator winding terminals are also connected to the diode bridge rectifier. Energy in the DC bus is converted to the parameters of the three-phase grid (400 V, 50 Hz by means of a three-phase voltage source inverter. Examples of numerical calculation results of the proposed energy generation system are presented in the end part of the paper.

  10. Adaptive nonlinear control of single-phase to three-phase UPS system

    Directory of Open Access Journals (Sweden)

    Kissaoui M.

    2014-01-01

    Full Text Available This work deals with the problems of uninterruptible power supplies (UPS based on the single-phase to three-phase converters built in two stages: an input bridge rectifier and an output three phase inverter. The two blocks are joined by a continuous intermediate bus. The objective of control is threefold: i power factor correction “PFC”, ii generating a symmetrical three-phase system at the output even if the load is unknown, iii regulating the DC bus voltage. The synthesis of controllers has been reached by two nonlinear techniques that are the sliding mode and adaptive backstepping control. The performances of regulators have been validated by numerical simulation in MATLAB / SIMULINK.

  11. Performance Analysis of Three-Phase Induction Motor with AC Direct and VFD

    Science.gov (United States)

    Kumar, Dinesh

    2018-03-01

    The electrical machine analysis and performance calculation is a very important aspect of efficient drive system design. The development of power electronics devices and power converters provide smooth speed control of Induction Motors by changing the frequency of input supply. These converters, on one hand are providing a more flexible speed control that also leads to problems of harmonics and their associated ailments like pulsating torque, distorted current and voltage waveforms, increasing losses etc. This paper includes the performance analysis of three phase induction motor with three-phase AC direct and variable frequency drives (VFD). The comparison has been concluded with respect to various parameters. MATLAB-SIMULINKTM is used for the analysis.

  12. System For Characterizing Three-Phase Brushless dc Motors

    Science.gov (United States)

    Howard, David E.; Smith, Dennis A.

    1996-01-01

    System of electronic hardware and software developed to automate measurements and calculations needed to characterize electromechanical performances of three-phase brushless dc motors, associated shaft-angle sensors needed for commutation, and associated brushless tachometers. System quickly takes measurements on all three phases of motor, tachometer, and shaft-angle sensor simultaneously and processes measurements into performance data. Also useful in development and testing of motors with not only three phases but also two, four, or more phases.

  13. An extended dual input dual output three level Z source inverter with improved switch loss reduction technique

    Directory of Open Access Journals (Sweden)

    N.B. Deshmukh

    2016-12-01

    Full Text Available Multilevel inverter (MLI is a proven technology used for industrial applications due to low output total harmonic distortion (THD, high power handling capability and low active device rating. Dual output inverter is a recent trend associated with inverter topologies for specialized applications. This paper deals with three phase three level dual input dual output inverter topology with minimum active device count. Reduction in switch count leads to reduction in losses and improves reliability. Both the input sources share power equally as neutral point current ripple is maintained low. For further reduction in switching losses at higher switching frequencies, the concept of “no switching zone” or discontinuous pulse width modulation (DPWM has been put forth recently. This paper proposes modification in the placement of “no switching zone” in order to optimize switching losses and output THD (output filtering requirements for low power factor load. This study also proposes novel graphical approach to analyze the loss reduction along with its effect on output THD. The sinusoidal PWM (SPWM is used which gives satisfactory switching loss reduction without complex calculations. Moreover, the proposed topology is generalized to provide dual output at higher voltage levels. It is seen that the components reduction phenomenon becomes more pronounced as number of levels goes on increasing. The proposed converter is simulated in MATLAB software environment and results are obtained.

  14. Direct-current vector control of three-phase grid-connected rectifier-inverter

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuhui; Haskew, Timothy A.; Hong, Yang-Ki; Xu, Ling [Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35475 (United States)

    2011-02-15

    The three-phase grid-connected converter is widely used in renewable and electric power system applications. Traditionally, control of the three-phase grid-connected converter is based on the standard decoupled d-q vector control mechanism. Nevertheless, the study of this paper shows that there is a limitation in the conventional standard vector control method. Some of the limitations have also been found recently by other researchers. To overcome the shortage of the conventional vector control technique, this paper proposes a new direct-current d-q vector control mechanism in a nested-loop control structure, based on which an optimal control strategy is developed in a nonlinear programming formulation. The behaviors of both the conventional and proposed control methods are compared and evaluated in simulation and laboratory hardware experiment environments, both of which demonstrates that the proposed approach is effective for grid-connected power converter control in a wide system conditions while the conventional standard vector control approach may behave improperly especially when the converter operates beyond its PWM saturation limit. (author)

  15. A Phase Current Reconstruction Approach for Three-Phase Permanent-Magnet Synchronous Motor Drive

    Directory of Open Access Journals (Sweden)

    Hao Yan

    2016-10-01

    Full Text Available Three-phase permanent-magnet synchronous motors (PMSMs are widely used in renewable energy applications such as wind power generation, tidal energy and electric vehicles owing to their merits such as high efficiency, high precision and high reliability. To reduce the cost and volume of the drive system, techniques of reconstructing three-phase current using a single current sensor have been reported for three-phase alternating current (AC control system using the power converts. In existing studies, the reconstruction precision is largely influenced by reconstructing dead zones on the Space Vector Pulse Width Modulation (SVPWM plane, which requires other algorithms to compensate either by modifying PWM modulation or by phase-shifting of the PWM signal. In this paper, a novel extended phase current reconstruction approach for PMSM drive is proposed. Six novel installation positions are obtained by analyzing the sampling results of the current paths between each two power switches. By arranging the single current sensor at these positions, the single current sensor is sampled during zero voltage vectors (ZVV without modifying the PWM signals. This proposed method can reconstruct the three-phase currents without any complex algorithms and is available in the sector boundary region and low modulation region. Finally, this method is validated by experiments.

  16. Analytical Design of Passive LCL Filter for Three-phase Two-level Power Factor Correction Rectifiers

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2017-01-01

    This paper proposes a comprehensive analytical LCL filter design method for three-phase two-level power factor correction rectifiers (PFCs). The high frequency converter current ripple generates the high frequency current harmonics that need to be attenuated with respect to the grid standards...

  17. Design and control of a three-phase four-leg inverter for solid-state transformer applications

    NARCIS (Netherlands)

    Shri, A.; Popovic, J.; Ferreira, J.A.; Gerber, M.B.

    2013-01-01

    This paper proposes the use of a three-phase four-leg (3P4L) converter in combination with an LCL filter for the inverter stage of a solid state transformer (SST). This configuration gives full control over the line-to-line, as well as the line-to-neutral voltage and currents, while providing

  18. Three phase active power filter with selective harmonics elimination

    Directory of Open Access Journals (Sweden)

    Sozański Krzysztof

    2016-03-01

    Full Text Available This paper describes a three phase shunt active power filter with selective harmonics elimination. The control algorithm is based on a digital filter bank. The moving Discrete Fourier Transformation is used as an analysis filter bank. The correctness of the algorithm has been verified by simulation and experimental research. The paper includes exemplary results of current waveforms and their spectra from a three phase active power filter.

  19. The Circuit-Level Decoupling Modulation Strategy for Three-Level Neutral-Point-Clamped (TL-NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2011-01-01

    In this paper, a circuit-level decoupling modulation strategy is proposed for the three-level (TL) neutral-point-clamped (NPC) inverters. With the proposed modulation scheme, the TL-NPC inverter can be decoupled into two three-level Buck converters in each defined operating section, which makes...

  20. A Fuzzy Logic Based Three phase Inverter with Single DC Source for Grid Connected PV System Employing Three Phase Transformer

    OpenAIRE

    Mani, venkatesan; Ramachandran, Rajeswari; N, Deverajan

    2016-01-01

    A fuzzy based three phase inverter with single DC source for grid connected photo voltaic (PV) system employing three phase transformer is presented in this paper. Space Vector Pulse Width Modulation (SVPWM) control scheme is effectively used to generate the appropriate switching sequences to the inverter switches. The intend of the fuzzy logic approach is to meet high quality output, fast response and high robustness. Finally Total Harmonics Distortion (THD) generated by the inverter is comp...

  1. A simple approach for fast controller prototyping for a three phase interleaved DC-DC converter

    OpenAIRE

    Gavriluta, Catalin; Citro, Costantino; Nisak, Khairul; Beltrán San Segundo, Héctor

    2012-01-01

    Initial control prototyping in power electronics is often a matter of trial and error because of the complicated mathematics involved in modeling systems based on their internal structure. Moreover, in practice, small changes as the introduction of a measurement filter or the change of the sensing system appear all the time. If the controller design method was based on the internal structure of the system, then these small changes would mean a re-iteration through all the cumbersome equati...

  2. Comparative Evaluation of Modeling Methods for Harmonic Stability Analysis of Three-Phase Voltage Source Converters

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    As the increasing of power electronics based systems, not only the component-based analysis but also a systematic interaction analysis with each other systems are being important. Especially studies about the stability and the harmonics interaction are critical in order to establish the required ...

  3. Vector control of three-phase AC/DC front-end converter

    Indian Academy of Sciences (India)

    directional power flow capability. A design procedure for selection of control parameters is discussed. A simple algorithm for unit-vector generation is presented. Starting current transients are studied with particular emphasis on high-power ...

  4. Performance characteristic of saturable three-phase interface transformers-investigations using a model simulation

    Energy Technology Data Exchange (ETDEWEB)

    Gierse, G; Pestka, J

    1981-11-01

    For electric locomotive drives equipped with converter fed squirrel cage induction motors the influence of different three-phase interface transformers on the smoothing of the motor currents is shown. In combination with a modified pulse-width-controlled thyristor firing system the size of the interface transformers can be greatly reduced without the distortion currents being greater than in the case of reactors in the motor supply lines. Finally, it is shown how the additional magnetic coupling of two driving systems can influence the behaviour of the two motors.

  5. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    OpenAIRE

    Cen Zhaohui

    2017-01-01

    Gird-connected Photo-Voltaic (PV) systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model....

  6. Sensitivity analysis of an LCL-filter-based three-phase active rectifier via a virtual circuit approach

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Chiarantoni, Ernesto; Aquila, Antonio Dell’

    2004-01-01

    Three-phase active rectifiers based on the voltage source converter topology can successfully replace traditional thyristor based rectifiers or diode bridge plus chopper in interfacing dc-systems to the grid. However, if the application in which they are employed has a high safety issue......, to the grid side stiffness and to the parameters of the controller has never been detailed considered. In this paper the experimental results of an LCL-filter-based three-phase active rectifier are analysed with the circuit theory approach. A ?virtual circuit? is synthesized in role of the digital controller...

  7. Three-phase electric drive with modified electronic smoothing inductor

    DEFF Research Database (Denmark)

    Singh, Yash Veer; Rasmussen, Peter Omand; Andersen, Torben Ole

    2010-01-01

    This paper presents a three-phase electric drive with a modified electronic smoothing inductor (MESI) having reduced size of passive components. The classical electronic smoothing inductor (ESI) is able to control a diode bridge output current and also reduce not only mains current harmonics...

  8. Three-Phase Flow and Capillarity in Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Helset, H.M.

    1996-06-01

    Multiphase flow occurs in most production operations on the reservoir rock of an oil field. Three-phase flow occurs in many oil recovery processes, such as gas or water alternating gas injection into water flooded reservoirs, thermal oil recovery and surfactant flooding. In this doctoral thesis, three-phase flow in porous media is modeled using the method of characteristics and simple wave theory. The general mathematical methods are used to model different flow processes: secondary migration of hydrocarbons, gravity segregated three-phase flow, and displacement experiments for relative permeabilities. The main conclusions from applying the methods to the migration process through a water-saturated carrier bed to a partially permeable seal are: (1) the three-phase solutions are generally dominated by the very low gas viscosity and gas density, (2) countercurrent flow and interference between the gas and oil mobilities can lead to trapping in situations where the permeability contrast between the seal and the carrier bed is insufficient to trap oil alone, (3) zones in which pressures exceed those from hydrostatic gradients (overpressured zones) exist even when the permeability contrast between the seal and the carrier bed is modest. The discussion of gravity segregated flow identifies stable displacement fronts, which usually occur only for a single value of the gas-water injection ratio. The new method developed for interpreting displacement experiments, with capillary pressure included, is based on the travelling wave solution of the flow equations. 185 refs., 69 figs., 5 tabs.

  9. Periodic Operation of Three-Phase Catalytic Reactors

    Czech Academy of Sciences Publication Activity Database

    Silveston, P.T.; Hanika, Jiří

    2005-01-01

    Roč. 82, č. 6 (2005), s. 1105-1142 ISSN 0008-4034 Institutional research plan: CEZ:AV0Z4072921 Keywords : three-phase reactors * trickle bed * periodic operation Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.574, year: 2005

  10. Controlling An Inverter-Driven Three-Phase Motor

    Science.gov (United States)

    Dolland, C.

    1984-01-01

    Control system for three-phase permanent-magnet motor driven by linecommutated inverter uses signals generated by integrating back emf of each phase of motor. High-pass filter network eliminates low-frequency components from control loop while maintaining desired power factor.

  11. A cascaded three-phase symmetrical multistage voltage multiplier

    International Nuclear Information System (INIS)

    Iqbal, Shahid; Singh, G K; Besar, R; Muhammad, G

    2006-01-01

    A cascaded three-phase symmetrical multistage Cockcroft-Walton voltage multiplier (CW-VM) is proposed in this report. It consists of three single-phase symmetrical voltage multipliers, which are connected in series at their smoothing columns like string of batteries and are driven by three-phase ac power source. The smoothing column of each voltage multiplier is charged twice every cycle independently by respective oscillating columns and discharged in series through load. The charging discharging process completes six times a cycle and therefore the output voltage ripple's frequency is of sixth order of the drive signal frequency. Thus the proposed approach eliminates the first five harmonic components of load generated voltage ripples and sixth harmonic is the major ripple component. The proposed cascaded three-phase symmetrical voltage multiplier has less than half the voltage ripple, and three times larger output voltage and output power than the conventional single-phase symmetrical CW-VM. Experimental and simulation results of the laboratory prototype are given to show the feasibility of proposed cascaded three-phase symmetrical CW-VM

  12. Three phase voltage measurements with simple open air sensors

    NARCIS (Netherlands)

    Heesch, van E.J.M.; Caspers, R.; Gulickx, P.F.M.; Jacobs, G.A.P.; Kersten, W.F.J.; Laan, van der P.C.T.

    1991-01-01

    A low cost, easy to install high-voltage measuring system is described for open air substations and overhead lines. Based on the Differentiating/Integrating (D/I) principle, three free-standing capacitive pickup electrodes are used to sense the three phase to ground voltages. Apart from the

  13. Lattice Boltzmann model for three-phase viscoelastic fluid flow

    Science.gov (United States)

    Xie, Chiyu; Lei, Wenhai; Wang, Moran

    2018-02-01

    A lattice Boltzmann (LB) framework is developed for simulation of three-phase viscoelastic fluid flows in complex geometries. This model is based on a Rothman-Keller type model for immiscible multiphase flows which ensures mass conservation of each component in porous media even for a high density ratio. To account for the viscoelastic effects, the Maxwell constitutive relation is correctly introduced into the momentum equation, which leads to a modified lattice Boltzmann evolution equation for Maxwell fluids by removing the normal but excess viscous term. Our simulation tests indicate that this excess viscous term may induce significant errors. After three benchmark cases, the displacement processes of oil by dispersed polymer are studied as a typical example of three-phase viscoelastic fluid flow. The results show that increasing either the polymer intrinsic viscosity or the elastic modulus will enhance the oil recovery.

  14. Losses in armoured three-phase submarine cables

    DEFF Research Database (Denmark)

    Ebdrup, Thomas; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2014-01-01

    The number of offshore wind farms will keep increasing in the future as a part of the shift towards a CO2 free energy production. The energy harvested from the wind farm must be brought to shore, which is often done by using a three-phase armoured submarine power cable. The use of an armour...... increases the losses in armoured cables compared to unarmoured cables. In this paper a thorough state of the art analysis is conducted on armour losses in three-phase armoured submarine power cables. The analysis shows that the IEC 60287-1-1 standard overestimates the armour losses which lead...... to the installation of cables with excessive phase conductor cross section. This paper also presents an example of the potential economic benefits of having a better knowledge of the losses introduced by the armour....

  15. Three phase load flow; Fluxo de carga trifasico

    Energy Technology Data Exchange (ETDEWEB)

    Zago, Maria Goretti

    1992-12-01

    The phase model which is used in the analysis and planning of electric power system is based on the hypothesis that both the transmission system and load are equilibrated. Such a system, which presents the advantage of being simple,presents satisfactory results in several cases, however, for certain applications this system is inadequate. this work presents an alternative method based on three-phase load flow which an be applied to electric power distribution networks 19 refs., 25 figs., 24 tabs.

  16. Three-Phase Harmonic Analysis Method for Unbalanced Distribution Systems

    Directory of Open Access Journals (Sweden)

    Jen-Hao Teng

    2014-01-01

    Full Text Available Due to the unbalanced features of distribution systems, a three-phase harmonic analysis method is essential to accurately analyze the harmonic impact on distribution systems. Moreover, harmonic analysis is the basic tool for harmonic filter design and harmonic resonance mitigation; therefore, the computational performance should also be efficient. An accurate and efficient three-phase harmonic analysis method for unbalanced distribution systems is proposed in this paper. The variations of bus voltages, bus current injections and branch currents affected by harmonic current injections can be analyzed by two relationship matrices developed from the topological characteristics of distribution systems. Some useful formulas are then derived to solve the three-phase harmonic propagation problem. After the harmonic propagation for each harmonic order is calculated, the total harmonic distortion (THD for bus voltages can be calculated accordingly. The proposed method has better computational performance, since the time-consuming full admittance matrix inverse employed by the commonly-used harmonic analysis methods is not necessary in the solution procedure. In addition, the proposed method can provide novel viewpoints in calculating the branch currents and bus voltages under harmonic pollution which are vital for harmonic filter design. Test results demonstrate the effectiveness and efficiency of the proposed method.

  17. Precise derating of three phase induction motors with unbalanced voltages

    International Nuclear Information System (INIS)

    Faiz, Jawad; Ebrahimpour, H.

    2007-01-01

    Performance analysis of three phase induction motors under supply voltage unbalance conditions is normally conducted using the well-known symmetrical components analysis. In this analysis, the voltage unbalance level at the terminals of the machine is assessed by means of the NEMA or IEC definitions. Both definitions lead to a relatively large error in predicting the performance of a machine. A method has recently been proposed in which, in addition to the voltage unbalance factor (VUF), the phase angle has been taken into account in the analysis. This means that the voltage unbalance factor is regarded as a complex value. This paper shows that although the use of the complex VUF reduces the computational error considerably, it is still high. This is proven by evaluating the derating factor of a three phase induction motor. A method is introduced to determine the derating factor precisely using the complex unbalance factor for an induction motor operating under any unbalanced supply condition. A practical case for derating of a typical three phase squirrel cage induction motor supplied by an unbalanced voltage is studied in the paper

  18. Mitigation of Flicker using STATCOM with Three-Level 12-pulse Voltage Source Inverter

    OpenAIRE

    Ali Z a'fari

    2011-01-01

    Voltage flicker is a disturbance in electrical power systems. The reason for this disturbance is mainly the large nonlinear loads such as electric arc furnaces. Synchronous static compensator (STATCOM) is considered as a proper technique to mitigate the voltage flicker. Application of more suitable and precise power electronic converter leads to a more precise performance of the compensator. In this paper a three-level 12-pulse voltage source inverter (VSI) with a 12-term...

  19. Current control design for three-phase grid-connected inverters using a pole placement technique based on numerical models

    OpenAIRE

    Citro, Costantino; Gavriluta, Catalin; Nizak Md, H. K.; Beltran, H.

    2012-01-01

    This paper presents a design procedure for linear current controllers of three-phase grid-connected inverters. The proposed method consists in deriving a numerical model of the converter by using software simulations and applying the pole placement technique to design the controller with the desired performances. A clear example on how to apply the technique is provided. The effectiveness of the proposed design procedure has been verified through the experimental results obtained with ...

  20. A new Zero Voltage Switching three-level NPC inverter

    DEFF Research Database (Denmark)

    He, Ning; Chen, Yenan; Xu, Dehong

    2015-01-01

    A novel Zero Voltage Switching (ZVS) three-level NPC inverter topology using a new ZVS Space Vector Modulation (SVM) scheme is proposed. A detailed operation analysis of ZVS three-level NPC inverter is given. The ZVS condition of the proposed ZVS inverter is derived and it can be achieved of all...

  1. LH2 three-phase pump control circuit description

    International Nuclear Information System (INIS)

    Pierce, W.

    1977-05-01

    A brief description and circuit drawings are given for a pump control system. The pump is used to circulate liquid hydrogen through the cell and heat exchanger of an LH 2 target. The pump is powered by three-phase 60 cycle power, and the control unit is powered from a positive and negative 24 V dc supply available in the NIM Bin. The control unit is packaged in a double-width NIM module. Drawings are given for the pump speed indicator, function generator, and power supply

  2. A fuzzy controlled three-phase centrifuge for waste separation

    International Nuclear Information System (INIS)

    Parkinson, W.J.; Smith, R.E.; Miller, N.

    1998-02-01

    The three-phase centrifuge technology discussed in this paper was developed by Neal Miller, president of Centech, Inc. The three-phase centrifuge is an excellent device for cleaning up oil field and refinery wastes which are typically composed of hydrocarbons, water, and solids. The technology is unique. It turns the waste into salable oil, reusable water, and landfill-able solids. No secondary waste is produced. The problem is that only the inventor can set up and run the equipment well enough to provide an optimal cleanup. Demand for this device has far exceeded a one man operation. There is now a need for several centrifuges to be operated at different locations at the same time. This has produced a demand for an intelligent control system, one that could replace a highly skilled operator, or at least supplement the skills of a less experienced operator. The control problem is ideally suited to fuzzy logic, since the centrifuge is a highly complicated machine operated entirely by the skill and experience of the operator. A fuzzy control system was designed for and used with the centrifuge

  3. Three-phase scintigraphy in the Sudeck syndrome

    International Nuclear Information System (INIS)

    Koppers, B.

    1982-01-01

    37 patients with clinically and radiologically proved reflex sympathetic dystrophy syndrome were scintigraphied by sup(99)mTc-MDP (three-phase scintigraphy). In 87% of the examinations (all three-phases) an increased tracer accumulation in the region of the affected limb could be seen scintigraphically. The majority of the positive results (92% resp. 87%) were found in the intervall phase (phase II) and the late phase (phase III) of the scintigraphic examinations. - We recommend a staging of the increase of the tracer accumulation when examing the reflex sympathetic dystrophy syndrome. This staging doesn't significantly correlate with the familiar clinical and radiological stagings. However it may be useful when assessing the course of the syndrome. - Increased tracer accumulations could be observed in the case of clinically, radiologically and scintigraphically manifest reflex sympathetic dystrophy syndrome in the region of the foot, frequently in the ipsilateral knee region, rarely in the ipsilateral hip joint region, although clinically the syndrome could not be observed in these regions. (orig.) [de

  4. Three-phase model and power-flow analysis of microgrids and virtual power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kamh, M.Z.; Iravani, R. [Toronto Univ., ON (Canada). Dept. of Electrical and Computer Engineering, Energy Systems Group

    2009-07-01

    A distributed energy resources (DER) unit can be a distributed generation unit, a distributed storage unit, or a hybrid of the two. It can be dispatchable, non-dispatchable or pseudo-dispatchable. A DER unit is connected to the hosting utility directly or via an electronic converter. A three-phase model and power-flow analysis of microgrids and virtual power plants was presented. The presentation discussed DER classification; microgrids and virtual power plants; motivations and goals; and a proposed DER model and power flow approach. Validation and results were also offered. The developed algorithm was implemented in the sequence-component frame using the MATLAB platform. Case studies were offered in order to verify the accuracy of the DER model and the power-flow program. It was concluded that the developed software accommodates different DER configurations and accurately reflects their control strategies. figs.

  5. Power Factor Correction Capacitors for Multiple Parallel Three-Phase ASD Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    Today’s three-phase Adjustable Speed Drive (ASD) systems still employ Diode Rectifiers (DRs) and Silicon-Controlled Rectifiers (SCRs) as the front-end converters due to structural and control simplicity, small volume, low cost, and high reliability. However, the uncontrollable DRs and phase......-controllable SCRs bring side-effects by injecting high harmonics to the grid, which will degrade the system performance in terms of lowering the overall efficiency and overheating the system if remain uncontrolled or unattenuated. For multiple ASD systems, certain harmonics in the entire system can be mitigated...... the power factor, passive capacitors can be installed, which yet can trigger the system resonance. Hence, this paper analyzes the resonant issues in multiple ASD systems with power factor correction capacitors. Potential damping solutions are summarized. Simulations are carried out, while laboratory tests...

  6. A vector modulated three-phase four-quadrant rectifier - Application to a dc motor drive

    Energy Technology Data Exchange (ETDEWEB)

    Jussila, Matti; Salo, Mika; Kaehkoenen, Lauri; Tuusa, Heikki

    2004-07-01

    This paper introduces a theory for a space vector modulation of a three-phase four-quadrant PWM rectifier (FQR). The presented vector modulation method is simple to realize with a microcontroller and it replaces the conventional modulation methods based on the analog technology. The FQR may be used to supply directly a dc load, e.g. a dc machine. The vector modulated FQR is tested in simulations supplying a 4.5 kW dc motor. The simulations show the benefits of the vector modulated FQR against thyristor converters: the supply currents are sinusoidal and the displacement power factor of the supply can be controlled. Furthermore the load current is smooth. (author)

  7. Three-Level Inverters with Common-Mode Voltage Cancellation Based on Synchronous Pulsewidth Modulation

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    A novel method of direct synchronous pulse-width modulation (PWM) is disseminated to three-level voltage source inverters with control algorithms with elimination of the common-mode voltages in three-phase drive systems with PWM. It provides smooth pulses-ratio changing and a quarter-wave symmetry...... of the voltage waveforms during the whole control range including overmodulation. Continuous, discontinuous and "direct-direct" schemes of synchronous PWM with both algebraic and trigonometric control functions have been analysed and compared. Simulations give the behaviour of the proposed methods and show some...... advantages of synchronous PWM in comparison with asynchronous at low ratios between the switching frequency and fundamental frequency....

  8. Synchronised Voltage Space Vector Modulation for Three-level Inverters with Common-mode Voltage Elimination

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    A novel method of direct synchronous pulse-width modulation (PWM) is disseminated to three-level voltage source inverters with control algorithms with elimination of the common-mode voltages in three-phase drive systems with PWM. It provides smooth pulses-ratio changing and a quarter-wave symmetry...... of the voltage waveforms during the whole control range including overmodulation. Continuous, discontinuous and "direct-direct" schemes of synchronous PWM with both algebraic and trigonometric control functions have been analysed and compared. Simulations give the behaviour of the proposed methods and show some...... advantages of synchronous PWM in comparison with asynchronous at low ratios between the switching frequency and fundamental frequency....

  9. Advanced computational model for three-phase slurry reactors

    International Nuclear Information System (INIS)

    Goodarz Ahmadi

    2001-10-01

    In the second year of the project, the Eulerian-Lagrangian formulation for analyzing three-phase slurry flows in a bubble column is further developed. The approach uses an Eulerian analysis of liquid flows in the bubble column, and makes use of the Lagrangian trajectory analysis for the bubbles and particle motions. An experimental set for studying a two-dimensional bubble column is also developed. The operation of the bubble column is being tested and diagnostic methodology for quantitative measurements is being developed. An Eulerian computational model for the flow condition in the two-dimensional bubble column is also being developed. The liquid and bubble motions are being analyzed and the results are being compared with the experimental setup. Solid-fluid mixture flows in ducts and passages at different angle of orientations were analyzed. The model predictions were compared with the experimental data and good agreement was found. Gravity chute flows of solid-liquid mixtures is also being studied. Further progress was also made in developing a thermodynamically consistent model for multiphase slurry flows with and without chemical reaction in a state of turbulent motion. The balance laws are obtained and the constitutive laws are being developed. Progress was also made in measuring concentration and velocity of particles of different sizes near a wall in a duct flow. The technique of Phase-Doppler anemometry was used in these studies. The general objective of this project is to provide the needed fundamental understanding of three-phase slurry reactors in Fischer-Tropsch (F-T) liquid fuel synthesis. The other main goal is to develop a computational capability for predicting the transport and processing of three-phase coal slurries. The specific objectives are: (1) To develop a thermodynamically consistent rate-dependent anisotropic model for multiphase slurry flows with and without chemical reaction for application to coal liquefaction. Also establish the

  10. Advanced computational model for three-phase slurry reactors

    International Nuclear Information System (INIS)

    Goodarz Ahmadi

    2000-11-01

    In the first year of the project, solid-fluid mixture flows in ducts and passages at different angle of orientations were analyzed. The model predictions are compared with the experimental data and good agreement was found. Progress was also made in analyzing the gravity chute flows of solid-liquid mixtures. An Eulerian-Lagrangian formulation for analyzing three-phase slurry flows in a bubble column is being developed. The approach uses an Eulerian analysis of gas liquid flows in the bubble column, and makes use of the Lagrangian particle tracking procedure to analyze the particle motions. Progress was also made in developing a rate dependent thermodynamically consistent model for multiphase slurry flows in a state of turbulent motion. The new model includes the effect of phasic interactions and leads to anisotropic effective phasic stress tensors. Progress was also made in measuring concentration and velocity of particles of different sizes near a wall in a duct flow. The formulation of a thermodynamically consistent model for chemically active multiphase solid-fluid flows in a turbulent state of motion was also initiated. The general objective of this project is to provide the needed fundamental understanding of three-phase slurry reactors in Fischer-Tropsch (F-T) liquid fuel synthesis. The other main goal is to develop a computational capability for predicting the transport and processing of three-phase coal slurries. The specific objectives are: (1) To develop a thermodynamically consistent rate-dependent anisotropic model for multiphase slurry flows with and without chemical reaction for application to coal liquefaction. Also to establish the material parameters of the model. (2) To provide experimental data for phasic fluctuation and mean velocities, as well as the solid volume fraction in the shear flow devices. (3) To develop an accurate computational capability incorporating the new rate-dependent and anisotropic model for analyzing reacting and

  11. Single-Carrier Modulation for Neutral-Point-Clamped Inverters in Three-Phase Transformerless Photovoltaic Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Cavalcanti, Marcelo C.; Farias, Alexandre M.

    2013-01-01

    Modulation strategy is one of the most important issues for three-level neutral-point-clamped inverters in three-phase transformerless photovoltaic systems. A challenge for modulation is how to keep the common-mode voltages constant to reduce the leakage currents. A single-carrier modulation...... strategy is proposed. It has a very simple structure, and the common-mode voltages can be kept constant with no need of complex space-vector modulation or multicarrier pulsewidth modulation. Experimental results verify the theoretical analysis and the effectiveness of the presented method....

  12. Intelligent System for Diagnosis of a Three-Phase Separator

    Directory of Open Access Journals (Sweden)

    Irina Ioniţă

    2016-03-01

    Full Text Available Intelligent systems for diagnosis have been used in a variety of domains: financial evaluation, credit scoring problem, identification of software and hardware problems of mechanical and electronic equipment, medical diagnosis, fault detection in gas-oil production plants etc. The goal of diagnosis systems is to classify the observed symptoms as being caused by some diagnosis class while advising systems perform such a classification and offer corrective remedies (recommendations. The current paper discuss the opportunity to combine more intelligent techniques and methodologies (intelligent agents, data mining and expert systems to increase the accuracy of results obtained from the diagnosis of a three-phase separator. The results indicate that the diagnosis hybrid system benefits from the advantages of each module component: intelligent agent module, data mining module and expert system module.

  13. Evaluation of Three-Phase Transformerless Photovoltaic Inverter Topologies

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper analyzes and compares three transformerless photovoltaic inverter topologies for three-phase grid connection with the main focus on the safety issues that result from the lack of galvanic isolation. A common-mode model, valid at frequencies lower than 50 kHz, is adopted to study...... the leakage current paths. The model is validated by both simulation and experimental results. These will be used to compare the selected topologies, and to explain the influence of system unbalance and the neutral conductor inductance on the leakage current. It will be demonstrated that the later has...... a crucial influence. Finally, a comparison of the selected topologies is carried out, based on the adopted modulation, connection of the neutral and its inductance, effects of unbalance conditions, component ratings, output voltage levels, and filter size....

  14. Mucormycosis and bone scintillography of three phases. Case description

    International Nuclear Information System (INIS)

    Papadakis S, M.; Larrea R, E.; Carrasco R, C.A.; Garrido A, R.A.; Olmedo T, D.; Perez C, M.

    2007-01-01

    The purpose of presenting this work, besides the interest that shows the mucormycosis pathology not so frequent, it is to carry out a clinical correlation photographic with the imagenology, particularly with the bone scintillography. In the Nuclear Medicine Service it is carried out bone scintillography of three phases previous endovenous administration of 30 mCi (1110 MBq) of 99m Tc-MDP. The images are obtained with a gamma camera model Elscint APEX SPX, first each 2 seconds during the first minute, then early image to the 5 minutes and finally the late ones to the 3 hs. The bone scintillography in the phases 2 and 3 detects bigger radioactive density in left hemi side, with increment of the osteoblast activity mainly in the medial border and the floor of the orbit, in the malar bone and a little more tenuous in the superior maxillary. (Author)

  15. Three-phase radionuclide bone imaging in sports medicine

    International Nuclear Information System (INIS)

    Rupani, H.D.; Holder, L.E.; Espinola, D.A.; Engin, S.I.

    1985-01-01

    Three-phase radionuclide bone (TPB) imaging was performed on 238 patients with sports-related injuries. A wide variety of lesions was encountered, but the most frequent lesions seen were stress fractures of the lower part of the leg at the junction of the middle and distal thirds of the posterior tibial cortex (42 of 79 lesions). There were no differences in the type, location, or distribution of lesions between males and females or between competitive and noncompetitive athletes. In 110 cases, bone stress lesions were often diagnosed when radiographs were normal, whereas subacute or chronic soft-tissue abnormalities had few specific scintigraphic features. TPB imaging provides significant early diagnostic information about bone stress lesions. Normal examination results (53 cases) exclude underlying osseous pathologic conditions

  16. Myositis ossificans and the three-phase bone scan

    International Nuclear Information System (INIS)

    Drane, W.E.

    1984-01-01

    Myositis ossificans circumscripta (or paraosteoarthropathy) in paraplegics has been a well known entity since its classic description in 1918 by Dejerine and Ceillier. The disease is characterized by ectopic bone formation, primarily occurring in the particular soft tissues of the hips and knees. Hypotheses concerning its origin have been proposed, but its etiology is still unknown. Myositis ossificans can occur after traumatic injury, but develops in paraplegics without apparent injury in the involved regions. Radionuclide techniques have been used in the evaluation of myositis ossificans, particularly with serial studies to stage the activity of the disease. The author reports a case of myositis ossificans in a paraplegic that emphasizes the benefit of the three-phase bone scan in the early diagnosis of this disorder

  17. Advanced nonlinear control of three phase series active power filter

    Directory of Open Access Journals (Sweden)

    Abouelmahjoub Y.

    2014-01-01

    Full Text Available The problem of controlling three-phase series active power filter (TPSAPF is addressed in this paper in presence of the perturbations in the voltages of the electrical supply network. The control objective of the TPSAPF is twofold: (i compensation of all voltage perturbations (voltage harmonics, voltage unbalance and voltage sags, (ii regulation of the DC bus voltage of the inverter. A controller formed by two nonlinear regulators is designed, using the Backstepping technique, to provide the above compensation. The regulation of the DC bus voltage of the inverter is ensured by the use of a diode bridge rectifier which its output is in parallel with the DC bus capacitor. The Analysis of controller performances is illustrated by numerical simulation in Matlab/Simulink environment.

  18. Transient three-phase three-component flow. Pt. 3

    International Nuclear Information System (INIS)

    Kolev, N.I.

    1986-05-01

    A mathematical model of a transient three-dimensional three-phase three-component flow described by three-velocity fields in porous body is presented. A combination of separated mass and energy equations together with mixture momentum equations for the flow is used. The mixture equations are used in diffusion form with the assumption that the diffusion velocity can be calculated from empirical correlations. An analytical coupling between the governing equations is developed for calculation of the pressure field. The system is discretized semiimplicitly in 3D-cylindrical space and different solution methods for the algebraic problem are presented. Finally, numerical examples and comparisons with experimental data demonstrate that the method presented is a powerful tool for numerical multiphase flow simulation. (orig.) [de

  19. Three-Phase Unbalanced Load Flow Tool for Distribution Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Kjær, Søren Bækhøj; Sera, Dezso

    2012-01-01

    This work develops a three-phase unbalanced load flow tool tailored for radial distribution networks based on Matlab®. The tool can be used to assess steady-state voltage variations, thermal limits of grid components and power losses in radial MV-LV networks with photovoltaic (PV) generators where...... most of the systems are single phase. New ancillary service such as static reactive power support by PV inverters can be also merged together with the load flow solution tool and thus, the impact of the various reactive power control strategies on the steady-state grid operation can be simply...... investigated. Performance of the load flow solution tool in the sense of resulting bus voltage magnitudes is compared and validated with IEEE 13-bus test feeder....

  20. Adjusting for Misclassification: A Three-Phase Sampling Approach

    Directory of Open Access Journals (Sweden)

    Sang Hailin

    2017-03-01

    Full Text Available The United States Department of Agriculture’s National Agricultural Statistics Service (NASS conducts the June Agricultural Survey (JAS annually. Substantial misclassification occurs during the prescreening process and from field-estimating farm status for nonresponse and inaccessible records, resulting in a biased estimate of the number of US farms from the JAS. Here, the Annual Land Utilization Survey (ALUS is proposed as a follow-on survey to the JAS to adjust the estimates of the number of US farms and other important variables. A three-phase survey design-based estimator is developed for the JAS-ALUS with nonresponse adjustment for the second phase (ALUS. A design-unbiased estimator of the variance is provided in explicit form.

  1. Three Phase Bone Scintigraphy in Active and Inactive Osteomyelitis

    International Nuclear Information System (INIS)

    Yang, Woo Jin; Chung, Soo Kyo; Ha, Hyun Kwon; Bahk, Yong Whee

    1988-01-01

    To Appreciate the value of bone scintigraphy in determination of the bony infection, we performed three phase bone scintigraphy in 34 cases of osteomyelitis of extremities prospectively. They were clinically inactive in 11 and active in 23 cases. We confirmed the active osteomyelitis by operation or aspiration within one week after scintigraphy. Perfusion, blood pool and delayed images were analyzed respectively and compared with the plain roentgenograms. All 23 active lesions showed diffusely increased perfusion in affected limbs. The areas of the increased activities on blood pool images were larger than or similar to those on delayed images in 17 cases (73.9%) with active osteomyelitis and smaller in 6 cases (26.1%). 5 of the latter 6 cases showed definite soft tissue activities on blood pool images. In inactive cases bone scintigrams were completely normal in 4 cases. Two of those were normal on plain films and remaining two showed mild focal bony sclerosis. Among 7 inactive lesions, perfusion was normal in 2 cases, diffusely increased in 4 cases and diffusely decreased in 1 case. 6 of these 7 cases showed increased activities both on blood pool and delayed images and the areas of increased activities on blood pool images didn't exceed those on delayed images. Bony sclerosis was noted on plain films in those 7 inactive lesions and the extent of the sclerosis correlated well to delayed images. Large blood pool activity was characteristics of active osteomyelitis. Normal three phase bone scintigram may indicate the time to terminate the treatment, but increased activity on perfusion and blood pool scans is not absolute indication of active lesion if the extent of the lesion on the blood pool image is smaller than that on delayed image and if no definite soft tissue activity is noted on perfusion and blood pool images in clinically inactive patient.

  2. Three-Phase Bone Scintigraphic Diagnosis of Acute Transient Synovitis

    International Nuclear Information System (INIS)

    Chung, Soo Kyo; Lee, Myung Hee; Kim, Choon Yul; Bahk, Yong Whee

    1985-01-01

    Acute transient synovitis of the hip presents clinically pain and limping. But in the majority of the cases, definite positive findings are not manifest in roentgenogram in its early phase. However radionuclide bone imaging combines with the assessment of vascularization and bone tracer uptake is of great value in solving this diagnostic problem. The materials for this study consisted of 29 children with acute transient synovitis of the hip, characterized by symptoms and physical signs of an arthritis, negative X-ray findings and disappearance of all symptoms and signs within a short period of time. They were twenty males and 9 females and age ranged from 1 to 12 years. We took pelvic roentgenogram in AP and frog-leg views. After intravenous bolus injection of 10 to 15 mCi of 99m Tc-methylene diphosphonate, 24 sequential image of the pelvis was taken at 2-second interval for blood flow study. The scintigrams were made using a gamma camera with high resolution parallel hole collimator. Blood pool imaging was obtained at 2 minutes after tracer administration. After 3 hours, static images were taken and then close-up image of the hip using pin-hole collimator was followed. The results were as follows: 1) Bone scintigram was much more sensitive than conventional roentgenogram in diagnosis of acute transient synovitis of the hip. 2) Three-phase imagings showed increased vascular activities in blood pool scintigrams in 96%. 3) Pin-hole imaging showed increased tracer uptake in the regional bones of the hip, particularly in the medial aspect of femoral head and acetabulum. 4) We confirmed that three-phase imaging reinforced with pin-hale technique were very useful in diagnose of acute transient synovitis of the hip.

  3. A novel loss reduced modulation strategy for matrix converters

    DEFF Research Database (Denmark)

    Helle, Lars; Munk-Nielsen, Stig

    2001-01-01

    This paper presents a new modulation strategy for three-phase to three-phase matrix converters. The new modulation strategy is applicable whenever the output voltage reference is below half the input voltage. By applying this new modulation method, the switching losses are reduced by 15-35% compa...

  4. Multilevel converters for 10 MW Wind Turbines

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2011-01-01

    Several promising multi-level converter configurations for 10 MW Wind Turbines both with direct drive and one-stage gear box drive using Permanent Magnet Synchronous Generator (PMSG) are proposed, designed and compared. Reliability is a crucial indicator for large scale wind power converters...... that the three-level and five-level H-bridge converter topologies both have potential to achieve improved thermal performances compared to the three-level Neutral-Point-Clamped converter topology in the wind power application....

  5. Current Harmonics Cancellation in Three-Phase Four-Wire Systems by Using a Four-Branch Star Filtering Topology

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Candela, J. I.; Luna, A.

    2009-01-01

    This paper presents a new solution for filtering current harmonics in three-phase four-wire networks. The original four-branch star (FBS) filter topology presented in this paper is characterized by a particular layout of single-phase inductances and capacitors, without using any transformer......, a specific implementation of a three-phase four-wire hybrid power filter is presented as an illustrative application of the filtering topology. An extensive evaluation using simulation and experimental results from a DSP-based laboratory prototype is conducted in order to verify and validate the good...... only passive components are employed, or as a hybrid filter, when its behavior is improved by integrating a power converter into the filter structure. The paper analyzes the proposed topology, and derives fundamental concepts about the control of the resulting hybrid power filter. From this analysis...

  6. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    Science.gov (United States)

    Cen, Zhaohui

    2017-09-01

    Gird-connected Photo-Voltaic (PV) systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT) is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.

  7. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    Directory of Open Access Journals (Sweden)

    Cen Zhaohui

    2017-09-01

    Full Text Available Gird-connected Photo-Voltaic (PV systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.

  8. Novel Topology of Three-Phase Electric Spring and Its Control

    DEFF Research Database (Denmark)

    Wang, Qingsong; Cheng, Ming; Jiang, Yunlei

    2017-01-01

    A novel topology is proposed for three-phase electric spring (TPES) to achieve specific functionalities. With respect to the existing one, the novel topology contains an additional three-phase transformer with the primaries located at the position of the non-critical three-phase load (NCL......) of the existing topology and its secondaries connected to the new three-phase NCL, thus forming a new three-phase smart load (SL). To control the novel topology, the so-called modified δ control utilized for the single-phase electric springs is extended to the three-phase case. Thanks to these solutions, TPES...

  9. Space vector modulation strategy for neutral-point voltage balancing in three-level inverter systems

    DEFF Research Database (Denmark)

    Choi, Uimin; Lee, Kyo Beum

    2013-01-01

    This study proposes a space vector modulation (SVM) strategy to balance the neutral-point voltage of three-level inverter systems. The proposed method is implemented by combining conventional symmetric SVM with nearest three-vector (NTV) modulation. The conventional SVM is converted to NTV...... modulation by properly adding or subtracting a minimum gate-on time. In addition, using this method, the switching frequency is reduced and a decrease of switching loss would be yielded. The neutral-point voltage is balanced by the proposed SVM strategy without additional hardware or complex calculations....... Simulation and experimental results are shown to verify the validity and feasibility of the proposed SVM strategy....

  10. Three-Phase Multistage System (DC-AC-DC-AC for Connecting Solar Cells to the Grid

    Directory of Open Access Journals (Sweden)

    Mahmudreza Changizian

    2017-11-01

    Full Text Available Inverter systems that feed electrical power from photovoltaic (PV system into the grid must convert the direct current of the PV array into the alternating current of the grid. In many applications, it is important for a converter to be lightweight, highly reliable, input/output isolated, flexible and operable in a boost mode. These features can be achieved by using a High-Frequency inverter which involves an isolated DC-DC stage and DC-AC section, which provides AC output. This paper proposes a new three phase topology, based on multi stage converter and PV system in order to use in medium and high power applications. The Perturb and Observe (P&O method is used for maximum power point tracking (MPPT control of PV array. The switching control signals for three-phase inverter are provided by hysteresis control method. Also, the comparison between the proposed topology and traditional structures has been conducted and finally the simulation researches are performed in a closed-loop control system by MATLAB/Simulink software to verify the operation of the proposed structure. The results represent better performance of the introduced system over traditional topologies.

  11. Comparison of Output Current Ripple in Single and Dual Three-Phase Inverters for Electric Vehicle Motor Drives

    Directory of Open Access Journals (Sweden)

    Jelena Loncarski

    2015-04-01

    Full Text Available The standard solution for the traction system in battery powered electric vehicles (EVs is a two-level (2L inverter feeding a three-phase motor. A simple and effective way to achieve a three-level (3L inverter in battery-supplied electric vehicles consists of using two standard three-phase 2L inverters with the open-end winding connection of standard three-phase ac motors. The 3L inverter solution can be usefully adopted in EVs since it combines several benefits such as current ripple reduction, increment of phase motor voltage with limited voltage ratings of the two battery banks, improvement in system reliability, etc. The reduction in current ripple amplitude is particularly relevant since it is a source of electromagnetic interference and audio noise from the inverter-motor power connection cables and from the motor itself. By increasing the inverter switching frequency the ripple amplitude is reduced, but the drive efficiency decreases due to the proportionally increased switching losses. In this paper the peak-to-peak ripple amplitude of the dual-2L inverter is evaluated and compared with the corresponding ripple of the single-2L inverter, considering the same voltage and power motor ratings. The ripple analysis is carried out as a function of the modulation index to cover the whole modulation range of the inverter, and the theoretical results are verified with experimental tests carried out by an inverter-motor drive prototype.

  12. Mathematical modeling of a three-phase trickle bed reactor

    Directory of Open Access Journals (Sweden)

    J. D. Silva

    2012-09-01

    Full Text Available The transient behavior in a three-phase trickle bed reactor system (N2/H2O-KCl/activated carbon, 298 K, 1.01 bar was evaluated using a dynamic tracer method. The system operated with liquid and gas phases flowing downward with constant gas flow Q G = 2.50 x 10-6 m³ s-1 and the liquid phase flow (Q L varying in the range from 4.25x10-6 m³ s-1 to 0.50x10-6 m³ s-1. The evolution of the KCl concentration in the aqueous liquid phase was measured at the outlet of the reactor in response to the concentration increase at reactor inlet. A mathematical model was formulated and the solutions of the equations fitted to the measured tracer concentrations. The order of magnitude of the axial dispersion, liquid-solid mass transfer and partial wetting efficiency coefficients were estimated based on a numerical optimization procedure where the initial values of these coefficients, obtained by empirical correlations, were modified by comparing experimental and calculated tracer concentrations. The final optimized values of the coefficients were calculated by the minimization of a quadratic objective function. Three correlations were proposed to estimate the parameters values under the conditions employed. By comparing experimental and predicted tracer concentration step evolutions under different operating conditions the model was validated.

  13. Bone graft viability evaluated by three phase bone scan

    International Nuclear Information System (INIS)

    Ljiljana Jaukovic Rajko Spaic; Marijan Novakovic; Srbislav Stosic

    2004-01-01

    Bone defects resulting war injury can be replaced by microvascular bone grafts from fibula. Aim: The aim of this study was to assess the value of three phase (3P) bone scintigraphy in the early detection of the bone graft complications. Method: 3P bone scans were performed in four patients (two after mandible reconstruction with micro vascular fibular bone grafts, one after fibular transplantation for ulnar and one with humeral reconstruction). First dynamic phase scan was performed immediately after iv injection of 740 MBq Tc- 99m DPD, acquiring 15 two seconds duration frames. Second, early static scan was performed during next 300 seconds, and third, delayed scan three hours later. All scans were obtained under the bone graft region. The scans were evaluated using ROI under graft region and the corresponding contra lateral area. Blood flow in graft region was determined using first phase scan, and tracer uptake in the same region was determined using second and third phase scans. Results: in all patients blood flow in graft region was particularly normal. Tracer uptake in one of two patients with mandible reconstruction was diffusely increased in graft, strongly suggesting infection; In the other patient delayed scan showed no tracer uptake in graft center .Both patients with ulnar and humeral reconstruction showed only slightly decreased tracer uptake in bone grafts. 3 phase bone scintigraphy may play a role in the evaluation of bone graft viability by predicting the infection and necrosis. (authors)

  14. ISOBUTANOL FROM SYNGAS IN A THREE PHASE SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Peter Tijrn

    2002-12-29

    With growing interest in oxygenates as octane booster for automotive fuels, various synthesis routes for these chemicals are being investigated. Among others, alternative routes to isobutene, the C4-components in MTBE-synthesis are under investigation. A promising path to isobutene is the heterogeneously catalyzed CO-hydrogenation to isobutanol with following dehydration (Fig. 1). As shown by thermodynamical studies, the heterogeneously catalyzed CO-hydrogenation to isobutanol is not expected to experience any thermodynamic constraints. However, heterogeneous hydrogenation of CO is a very exothermic process, a problem which can only be partly solved when being conducted in a plug flow reactor. When carried out in reaction vessels with moving catalyst bed (e.g. three phase stirred tank), heat transfer problems can be resolved, along with additional benefits connected with this reactor type. Several heterogeneous catalytic systems have been under investigation for their capability of isobutanol synthesis from syngas. Most promising catalysts for an active and selective isobutanol synthesis from CO are modified high temperature methanol catalysts.

  15. Clinical significant of three phase radionuclide bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Suh, Jin Suck; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1989-04-15

    Three phase radionuclide bone scan, consisting of a radionuclide angiogram, an immediate postinjection blood pool image, and 4hr delayed images, was randomly performed in 182 patients, who had been suffered from either local pain or tenderness. Authors analysed 3 phase bone scan in 74 patients with correct diagnosis proven surgically or clinically, from July 1987 to August, 1988. The results were as follows: 1. Overall sensitivity of 3 phase bone scan was 85.4%: sensitivity in patients with an osseous lesion was 90.4% as opposed to 72.7% in patients with a nonosseous lesion. 2. There was no difference in the detection rate of the osseous lesions between the 3 phase bone scan and the delayed image bone scan. However, because the detection rate was higher on the 3 phase bone scan than it was on only the delayed image bone scan (55%) in instance of the nonosseous lesion, we would suggest that 3 phase bone scan might be obtained in cases suspected of the nonosseous lesions. 3. When the presumptive diagnosis was a bone tumor, sensitivity and specificity for malignancy were 67%, 100% respectively. 4. In differentiating osteomyelitis from cellulitis, sensitivity was 94%, specificity was 100%. 5. 3 phase bone scan was able to provide the precise information about either vasculaturity or localization of lesion in some cases of soft tissue mass and avascular necrosis of hips.

  16. An EMTDC Model of a Three Level four MVAR Compensator

    DEFF Research Database (Denmark)

    Rasmussen, Tonny Wederberg

    1997-01-01

    The paper discusses the dynamic characteristics of a three level ±4mvar solid state var compensator which is built and will be used for dynamic reactive power compensation in a wind farm. An investigation has been carried out of the influence of the compensator reactor, the DC intermediate voltage...

  17. experimental implementation of single-phase, three-level, sinusoidal

    African Journals Online (AJOL)

    Page 1 ... of many multilevel inverter configurations. This paper presents an experimental report of a simplified topology for single-phase, SPWM, three-level voltage source inverter wit R-L load. To keep the power circuit ... employed in many industrial applications such as variable speed drives, uninterruptible power sup-.

  18. 40 CFR 761.346 - Three levels of sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Three levels of sampling. 761.346... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal...

  19. Power Electronic Transformer based Three-Phase PWM AC Drives

    Science.gov (United States)

    Basu, Kaushik

    A Transformer is used to provide galvanic isolation and to connect systems at different voltage levels. It is one of the largest and most expensive component in most of the high voltage and high power systems. Its size is inversely proportional to the operating frequency. The central idea behind a power electronic transformer (PET) also known as solid state transformer is to reduce the size of the transformer by increasing the frequency. Power electronic converters are used to change the frequency of operation. Steady reduction in the cost of the semiconductor switches and the advent of advanced magnetic materials with very low loss density and high saturation flux density implies economic viability and feasibility of a design with high power density. Application of PET is in generation of power from renewable energy sources, especially wind and solar. Other important application include grid tied inverters, UPS e.t.c. In this thesis non-resonant, single stage, bi-directional PET is considered. The main objective of this converter is to generate adjustable speed and magnitude pulse width modulated (PWM) ac waveforms from an ac or dc grid with a high frequency ac link. The windings of a high frequency transformer contains leakage inductance. Any switching transition of the power electronic converter connecting the inductive load and the transformer requires commutation of leakage energy. Commutation by passive means results in power loss, decrease in the frequency of operation, distortion in the output voltage waveform, reduction in reliability and power density. In this work a source based partially loss-less commutation of leakage energy has been proposed. This technique also results in partial soft-switching. A series of converters with novel PWM strategies have been proposed to minimize the frequency of leakage inductance commutation. These PETs achieve most of the important features of modern PWM ac drives including 1) Input power factor correction, 2) Common

  20. ADVANCED COMPUTATIONAL MODEL FOR THREE-PHASE SLURRY REACTORS

    International Nuclear Information System (INIS)

    Ahmadi, Goodarz

    2004-01-01

    In this project, an Eulerian-Lagrangian formulation for analyzing three-phase slurry flows in a bubble column was developed. The approach used an Eulerian analysis of liquid flows in the bubble column, and made use of the Lagrangian trajectory analysis for the bubbles and particle motions. The bubble-bubble and particle-particle collisions are included the model. The model predictions are compared with the experimental data and good agreement was found An experimental setup for studying two-dimensional bubble columns was developed. The multiphase flow conditions in the bubble column were measured using optical image processing and Particle Image Velocimetry techniques (PIV). A simple shear flow device for bubble motion in a constant shear flow field was also developed. The flow conditions in simple shear flow device were studied using PIV method. Concentration and velocity of particles of different sizes near a wall in a duct flow was also measured. The technique of Phase-Doppler anemometry was used in these studies. An Eulerian volume of fluid (VOF) computational model for the flow condition in the two-dimensional bubble column was also developed. The liquid and bubble motions were analyzed and the results were compared with observed flow patterns in the experimental setup. Solid-fluid mixture flows in ducts and passages at different angle of orientations were also analyzed. The model predictions were compared with the experimental data and good agreement was found. Gravity chute flows of solid-liquid mixtures were also studied. The simulation results were compared with the experimental data and discussed A thermodynamically consistent model for multiphase slurry flows with and without chemical reaction in a state of turbulent motion was developed. The balance laws were obtained and the constitutive laws established

  1. Matrix converter applied to energy saving for street lighting systems

    OpenAIRE

    Román Lumbreras, Manuel; Velasco Quesada, Guillermo; Conesa Roca, Alfons

    2010-01-01

    This work presents a three-phase AC-AC converter, with independent phase control, based on matrix-converter structure. This converter is applied to electrical energy saving on the public lighting systems by means of regulation and control of the voltage applied to the lamps. The developed converter represents a technological improvement with respect to the traditional systems based on an autotransformer: it reduces system cost and volume, and increases lamps lifetime.

  2. Defeating the Islamic State at Three Levels of War

    Science.gov (United States)

    2016-05-13

    FINAL 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Defeating the Islamic State at Three Levels of War 5a...ABSTRACT The Islamic State (IS) continues to be weakened at the operational level in Syria and Iraq. To remain legitimate, the insurgency is shifting...paper concludes with recommendations to aid planners in developing a concept to achieve the President’s desired end state. 15. SUBJECT TERMS Islamic

  3. Control of Grid Connected Photovoltaic System Using Three-Level T-Type Inverter

    Science.gov (United States)

    Zorig, Abdelmalik; Belkeiri, Mohammed; Barkat, Said; Rabhi, Abdelhamid

    2016-08-01

    Three-level T-Type inverter (3LT2I) topology has numerous advantageous compared to three-level neutral-point-clamped (NPC) inverter. The main benefits of 3LT2I inverter are the efficiency, inverter cost, switching losses, and the quality of output voltage waveforms. In this paper, a photovoltaic distributed generation system based on dual-stage topology of DC-DC boost converter and 3LT2I is introduced. To that end, a decoupling control strategy of 3LT2I is proposed to control the current injected into the grid, reactive power compensation, and DC-link voltage. The resulting system is able to extract the maximum power from photovoltaic generator, to achieve sinusoidal grid currents, and to ensure reactive power compensation. The voltage-balancing control of two split DC capacitors of the 3LT2I is achieved using three-level space vector modulation with balancing strategy based on the effective use of the redundant switching states of the inverter voltage vectors. The proposed system performance is investigated at different operating conditions.

  4. Analysis and MPPT control of a wind-driven three-phase induction generator feeding single-phase utility grid

    Directory of Open Access Journals (Sweden)

    Krishnan Arthishri

    2017-05-01

    Full Text Available In this study, a three-phase diode bridge rectifier and a single-phase voltage source inverter topology has been proposed for feeding single-phase utility grid employing a three-phase induction generator fed from wind energy. A self-excited induction generator configuration has been chosen for wide speed operation of wind turbine system, which gives the scope for extracting maximum power available in the wind. In addition to maximum power point tracking (MPPT, the generator can be loaded to its rated capacity for feeding single-phase utility grid using a three-phase induction machine, whereas it is not possible with existing configurations because of the absence of power converters. For the proposed system, MPPT algorithm has been devised by continuously monitoring the grid current and a proportional resonant controller has been employed for grid synchronisation of voltage source inverter with single-phase grid. A MATLAB/Simulink model of the proposed system has been developed to ascertain its successful working by predetermining the overall performance characteristics. The present proposal has also been tested with sag, swell and distortion in the grid voltage. The control strategy has been implemented using field programmable gate array (FPGA controller with modularised programming approach. The efficacy of the system has been demonstrated with the results obtained from an experimental set-up in the laboratory.

  5. A New 4D Imaging Method for Three-Phase Analogue Experiments in Volcanology (and Other Three-Phase Systems)

    Science.gov (United States)

    Oppenheimer, J.; Patel, K. B.; Lev, E.; Hillman, E. M. C.

    2017-12-01

    Bubbles and crystals suspended in magmas interact with each other on a small scale, which affects large-scale volcanic processes. Studying these interactions on relevant scales of time and space is a long-standing challenge. Therefore, the fundamental explanations for the behavior of bubble- and crystal-rich magmas are still largely speculative. Recent application of X-ray tomography to experiments with synthetic magmas has already improved our understanding of small-scale 4D (3D + time) phenomena. However, this technique has low imaging rates Confocally Aligned Planar Excitation (SCAPE) microscopy. This method based on laser-fluorescence has been used to image live biological processes at high speed and in 3D. It allows imaging rates of up to several hundred vps and image volumes up to 1 x 1 x 0.5 mm3, with a trade-off between speed and spatial resolution. We ran two sets of experiments with silicone oil and soda-lime glass beads of <50 µm diameter, contained within a vertical glass casing 50 x 5 x 4 mm3. We used two different bubble generation methods. In the first set of experiments, small air bubbles (< 1 mm) were introduced through a hole at the bottom of the sample and allowed to rise through a suspension with low-viscosity oil. We successfully imaged bubble rise and particle movements around the bubble. In the second set, bubbles were generated by mixing acetone into the suspension and decreasing the surface pressure to cause a phase change to gaseous acetone. This bubble generation method compared favorably with previous gum rosin-acetone experiments: they provided similar degassing behaviors, along with more control on suspension viscosity and optimal optical properties for laser transmission. Large volumes of suspended bubbles, however, interfered with the laser path. In this set, we were able to track bubble nucleation sites and nucleation rates in 4D. This promising technique allows the study of small-scale interactions in two- and three-phase systems

  6. Power coordinated control method with frequency support capability for hybrid single/three-phase microgrid

    DEFF Research Database (Denmark)

    Zhou, Xiaoping; Chen, Yandong; Zhou, Leming

    2018-01-01

    storage unit (ESU) are added into hybrid single/three-phase microgrid, and a power coordinated control method with frequency support capability is proposed for hybrid single/three-phase microgrid in this study. PEU is connected with three single-phase microgrids to coordinate power exchange among three...... phases and provide frequency support for hybrid microgrid. Meanwhile, a power coordinated control method based on the droop control is proposed for PEU to alleviate three-phase power imbalance and reduce voltage fluctuation of hybrid microgrid. Besides, ESU is injected into the DC-link to buffer......Due to the intermittent output power of distributed generations (DGs) and the variability of loads, voltage fluctuation and three-phase power imbalance easily occur when hybrid single/three-phase microgrid operates in islanded mode. To address these issues, the power exchange unit (PEU) and energy...

  7. Multilevel Direct Repair Surgery for Three-Level Lumbar Spondylolysis

    Directory of Open Access Journals (Sweden)

    Tetsu Arai

    2013-01-01

    Full Text Available A 45-year-old man presented to our clinic requesting evaluation for surgical treatment of chronic low back pain of more than 20 years duration. He was diagnosed with 3-level lumbar spondylolysis at L3–5. Direct repair using the pedicle screw and hook-rod system was conducted for all three levels. After the surgery, his low back pain completely disappeared. Six months later, he felt discomfort and heard a metallic sound as he twisted his trunk. Computed tomography and radiography indicated that the hook head for L3 and the screw head for L4 were interfering with each other, causing the sound. We confirmed bony union at L3 and removed the L3 system. Surgeons should be aware of such complications if direct repair using a pedicle screw and hook-rod system is conducted for multilevel spondylolysis.

  8. Self-commissioning notch filter for active damping in three phase LCL-filter based grid converters

    DEFF Research Database (Denmark)

    Alzola, Rafael Pena; Liserre, Marco; Blaabjerg, Frede

    2013-01-01

    inductance variations it is proposed to estimate the resonance frequency by means of Fourier analysis. The Goertzel algorithm, instead of the FFT, is used to reduce the calculation and memory requirements. Thus, the proposed self-commissioning notch filter results robust and consumes little computational...

  9. Design Research on Three-Phase PWM Rectifier Based on Double Closed Loop Control Technology

    Directory of Open Access Journals (Sweden)

    Guang Ya LIU

    2014-02-01

    Full Text Available Based on the high frequency of three-phase voltage source PWM rectifier, this paper established a mathematical model of three phase current inner ring and outer ring voltage, and put forward the setting method of three phase double closed loop control. Finally, it was verified through simulation. The experimental results show that Three-phase output of DC voltage is stable with the operation of regulating systems, the current flowing into the grid tends to be sinusoidal and power factor is close to 1, which greatly reduce the interference of harmonics on the grid, thus improve grid operation.

  10. Hydrogen converters

    International Nuclear Information System (INIS)

    Mondino, Angel V.

    2003-01-01

    The National Atomic Energy Commission of Argentina developed a process of 99 Mo production from fission, based on irradiation of uranium aluminide targets with thermal neutrons in the RA-3 reactor of the Ezeiza Atomic Centre. These targets are afterwards dissolved in an alkaline solution, with the consequent liberation of hydrogen as the main gaseous residue. This work deals with the use of a first model of metallic converter and a later prototype of glass converter at laboratory scale, adjusted to the requirements and conditions of the specific redox process. Oxidized copper wires were used, which were reduced to elementary copper at 400 C degrees and then regenerated by oxidation with hot air. Details of the bed structure and the operation conditions are also provided. The equipment required for the assembling in cells is minimal and, taking into account the operation final temperature and the purge with nitrogen, the procedure is totally safe. Finally, the results are extrapolated for the design of a converter to be used in a hot cell. (author)

  11. Instantaneous Power Compensation in Three-Phase Systems by Using p-q-r Theory

    DEFF Research Database (Denmark)

    Kim, Hyosung; Blaabjerg, Frede; Bak-Jensen, Birgitte

    2002-01-01

    Three linearly independent instantaneous powers have been defined in the time domain in three-phase four-wire systems with the use of p-q-r theory. Any three-phase circuit can be transformed into three single-phase circuits by the p-q-r transformation Thus the instantaneous powers in any three...

  12. Three-Phase and Six-Phase AC at the Lab Bench

    Science.gov (United States)

    Caplan, George M.

    2009-01-01

    Utility companies generate three-phase electric power, which consists of three sinusoidal voltages with phase angles of 0 degrees, 120 degrees, and 240 degrees. The ac generators described in most introductory textbooks are single-phase generators, so physics students are not likely to learn about three-phase power. I have developed a simple way…

  13. Diagnosis of the three-phase induction motor using thermal imaging

    Science.gov (United States)

    Glowacz, Adam; Glowacz, Zygfryd

    2017-03-01

    Three-phase induction motors are used in the industry commonly for example woodworking machines, blowers, pumps, conveyors, elevators, compressors, mining industry, automotive industry, chemical industry and railway applications. Diagnosis of faults is essential for proper maintenance. Faults may damage a motor and damaged motors generate economic losses caused by breakdowns in production lines. In this paper the authors develop fault diagnostic techniques of the three-phase induction motor. The described techniques are based on the analysis of thermal images of three-phase induction motor. The authors analyse thermal images of 3 states of the three-phase induction motor: healthy three-phase induction motor, three-phase induction motor with 2 broken bars, three-phase induction motor with faulty ring of squirrel-cage. In this paper the authors develop an original method of the feature extraction of thermal images MoASoID (Method of Areas Selection of Image Differences). This method compares many training sets together and it selects the areas with the biggest changes for the recognition process. Feature vectors are obtained with the use of mentioned MoASoID and image histogram. Next 3 methods of classification are used: NN (the Nearest Neighbour classifier), K-means, BNN (the back-propagation neural network). The described fault diagnostic techniques are useful for protection of three-phase induction motor and other types of rotating electrical motors such as: DC motors, generators, synchronous motors.

  14. Analysis of Magnetically-Coupled Impedance Source Three-Phase Four-Switch Inverters

    DEFF Research Database (Denmark)

    Li, Kerui; Abdelhakim, Ahmed; Yang, Yongheng

    2017-01-01

    In this paper, magnetically-coupled impedance source (MCIS) three-phase four-switch inverters are introduced for renewable energy applications. This inverter utilizes two single-phase MCIS inverters to obtain a three-phase output, where less component-count is achieved in order to reduce the inve......In this paper, magnetically-coupled impedance source (MCIS) three-phase four-switch inverters are introduced for renewable energy applications. This inverter utilizes two single-phase MCIS inverters to obtain a three-phase output, where less component-count is achieved in order to reduce...... the inverter volume. On the other hand, as a result of the reduced number of switches, the proposed inverter suffers from higher voltage stresses. The MCIS inverters are first reviewed. Then, the modulation and operation principle of the MCIS three-phase inverter topology are introduced before sizing...

  15. Power sharing algorithm for vector controlled six-phase AC motor with four customary three-phase voltage source inverter drive

    Directory of Open Access Journals (Sweden)

    Sanjeevikumar Padmanaban

    2015-09-01

    Full Text Available This paper considered a six-phase (asymmetrical induction motor, kept 30° phase displacement between two set of three-phase open-end stator windings configuration. The drive system consists of four classical three-phase voltage inverters (VSIs and all four dc sources are deliberately kept isolated. Therefore, zero-sequence/homopolar current components cannot flow. The original and effective power sharing algorithm is proposed in this paper with three variables (degree of freedom based on synchronous field oriented control (FOC. A standard three-level space vector pulse width modulation (SVPWM by nearest three vectors (NTVs approach is adopted to regulate each couple of VSIs. The proposed power sharing algorithm is verified by complete numerical simulation modeling (Matlab/Simulink-PLECS software of whole ac drive system by observing the dynamic behaviors in different designed condition. Set of results are provided in this paper, which confirms a good agreement with theoretical development.

  16. Model of Transient Process Where Three-Phase Transducer Feeds Induction Motor Equivalent as a Variable Active-Inductive Load

    Directory of Open Access Journals (Sweden)

    Nenad Marković

    2016-01-01

    Full Text Available The paper presents a new approach in the analysis of a transient state in a system where the feeding source is a transducer-IGBT inverter and load is introduced through the induction motor with its R-L parameters. Induction motors with different parameters of powers and power factors are tested. MATLAB simulation of the three-phase inverter that feeds the induction machine has replaced the missing lab equipment with which mathematical model of this system was verified. According to the selected parameters of the inverter and induction machine and through the simulation in the MATLAB program, the results are obtained in the form of diagrams that verify the model of a transient state of the induction machine operation when it operates as a motor which is presented as a variable R-L load. The transient process of the system three-phase bridge inverter whose active-inductive load is the induction machine in the conditions of the change of the load parameters is analyzed. The model of the transient process in the system formed by the inverter in PWM (Pulse Width Modulation converter and induction machine is developed in the time domain and phase coordinates.

  17. Neural network-based voltage regulator for an isolated asynchronous generator supplying three-phase four-wire loads

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Bhim; Kasal, Gaurav Kumar [Department of Electrical Engineering, Indian Institute of Technology, Delhi, Hauz-Khas, New Delhi 110016 (India)

    2008-06-15

    This paper deals with a neural network-based solid state voltage controller for an isolated asynchronous generator (IAG) driven by constant speed prime mover like diesel engine, bio-gas or gasoline engine and supplying three-phase four-wire loads. The proposed control scheme uses an indirect current control and a fast adaptive linear element (adaline) based neural network reference current extractor, which extracts the real positive sequence current component without any phase shift. The neutral current of the source is also compensated by using three single-phase bridge configuration of IGBT (insulated gate bipolar junction transistor) based voltage source converter (VSC) along-with single-phase transformer having self-supported dc bus. The proposed controller provides the functions as a voltage regulator, a harmonic eliminator, a neutral current compensator, and a load balancer. The proposed isolated electrical system with its controller is modeled and simulated in MATLAB along with Simulink and PSB (Power System Block set) toolboxes. The simulated results are presented to demonstrate the capability of an isolated asynchronous generating system driven by a constant speed prime mover for feeding three-phase four-wire loads. (author)

  18. Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults

    DEFF Research Database (Denmark)

    Afshari, Ehsan; Moradi, Gholam Reza; Rahimi, Ramin

    2017-01-01

    Power quality and voltage control are among the most important aspects of the grid-connected power converter operation under faults. Non-sinusoidal current is injected during unbalanced voltage sag and active or/and reactive power includes double frequency content. This paper introduces a novel...... control strategy to mitigate the double grid frequency oscillations in the active power and dc-link voltage of the two-stage three-phase grid-connected Photovoltaic (PV) inverters during unbalanced faults. With the proposed control method, PV inverter injects sinusoidal currents under unbalanced grid...... faults. In addition, an efficient and easy-to-implement current limitation method is introduced, which can effectively limit the injected currents to the rated value during faults. In this case, the fault-ride-through operation is ensured and it will not trigger the overcurrent protection. A non...

  19. LCL filter design for three-phase two-level power factor correction using line impedance stabilization network

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2016-01-01

    This paper presents LCL filter design method for three-phase two-level power factor correction (PFC) using line impedance stabilization network (LISN). A straightforward LCL filter design along with variation in grid impedance is not simply achievable and inevitably lead to an iterative solution...... for filter. By introducing of fast power switches for PFC applications such as silicon-carbide, major current harmonics around the switching frequency drops in the region that LISN can actively provide well-defined impedance for measuring the harmonics (i.e. 9 kHz- 30MHz). Therefore, LISN can be replaced...... is derived using the current ripple behavior of converter-side inductor. The grid-side inductor is achieved as a function of LISN impedance to fulfill the grid regulation. To verify the analyses, an LCL filter is designed for a 5 kW SiC-based PFC. The simulation and experimental results support the validity...

  20. New strategy for eliminating zero-sequence circulating current between parallel operating three-level NPC voltage source inverters

    DEFF Research Database (Denmark)

    Li, Kai; Dong, Zhenhua; Wang, Xiaodong

    2018-01-01

    buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters......, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can...... be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter....

  1. Ray converter

    International Nuclear Information System (INIS)

    Reiss, K.H.

    1976-01-01

    In a radiographic system a converter is used for changing image forming intensity distribution in a bundle of penetrating rays into a flow of electrically charged particles by electrodes located in a gas space and partly latticed (grids) which lie at potentials stepped from cathode to anode. The invention is particularly characterized by the provision of at least two grids extending between and parallel to the cathode and the anode. The electrical field which lies between two electrodes lies at least between the grids located closest to the cathode being to the extent of between 1 and 10 percent, in the average preferably 3 percent below the electrical break down field in the gas in a homogeneous electrical field

  2. Research on Control System of Three - phase Brushless DC Motor for Electric Vehicle

    Science.gov (United States)

    Wang, Zhiwei; Jin, Hai; Guo, Jie; Su, Jie; Wang, Miao

    2017-12-01

    In order to study the three-phase brushless motor control system of electric vehicle, Freescale9S12XS128 chip is used as the control core, and the power MOSFET is used as the inverter device. The software is compiled by Codewarrior software. The speed control link adopts open-loop control, and the control chip collects the external sensor signal voltage Change control PWM signal output control three-phase brushless DC motor speed. The whole system consists of Hall position detection module, current detection module, power drive module and voltage detection module. The basic functions of three-phase brushless DC motor drive control are realized.

  3. Power Loss Calculation and Thermal Modelling for a Three Phase Inverter Drive System

    Directory of Open Access Journals (Sweden)

    Z. Zhou

    2005-12-01

    Full Text Available Power losses calculation and thermal modelling for a three-phase inverter power system is presented in this paper. Aiming a long real time thermal simulation, an accurate average power losses calculation based on PWM reconstruction technique is proposed. For carrying out the thermal simulation, a compact thermal model for a three-phase inverter power module is built. The thermal interference of adjacent heat sources is analysed using 3D thermal simulation. The proposed model can provide accurate power losses with a large simulation time-step and suitable for a long real time thermal simulation for a three phase inverter drive system for hybrid vehicle applications.

  4. Reversible thyristor converters of brushless synchronous compensators

    Directory of Open Access Journals (Sweden)

    А.М.Galynovskiy

    2013-12-01

    Full Text Available Behavior of models of three-phase-to-single-phase rotary reversible thyristor converters of brushless synchronous compensators in a circuit simulation system is analyzed. It is shown that combined control mode of opposite-connected thyristors may result in the exciter armature winding short circuits both at the thyristor feed-forward and lagging current delay angles. It must be taken into consideration when developing brushless compensator excitation systems.

  5. Single-current-sensor-based active front-end-converter-fed four ...

    Indian Academy of Sciences (India)

    Joseph Kiran Banda

    Keywords. Field-oriented control; vector control of induction motor; active front end converter; power factor correction .... sinusoidal three-phase input currents applied to the stator. ... with necessary feed-forward terms are employed to control.

  6. Modeling and Analysis of a Three-Phase Solid-State Var ...

    African Journals Online (AJOL)

    Modeling and Analysis of a Three-Phase Solid-State Var Compensator (SSVC) ... Nigerian Journal of Technology. Journal Home ... The problems associated with the flow of reactive power in transmission and distribution lines are well known.

  7. High performance predictive current control of a three phase VSI: An ...

    Indian Academy of Sciences (India)

    ... current control of a three phase VSI: An experimental assessment ... Voltage source inverter; two level inverter; predictive current control; weighting factor ... Conventionally, for reference current tracking control in a two level VSI, the objective ...

  8. Research on a Compound Control Strategy of Three-Phase Inverter for Unbalanced Loads

    Directory of Open Access Journals (Sweden)

    Yue Gaili

    2017-01-01

    Full Text Available To solve the problem of unbalanced output voltage of inverter under three-phase unbalanced load. In this paper, the main circuit topology using three-phase three-wire inverter topology. Established the mathematical model in several different coordinate system of the three-phase inverter. A compound control method is proposed by combining voltage current dual loop control method and repetitive control method, The control method is realized in three - phase 400 Hz inverter, and can meet the demand of unbalanced load to inverter, the reliability of the inverter circuit is improved. At the end of this paper, Matlab simulation analysis and experimental results are given, it is proved that the composite control method designed in this paper has a strong ability of unbalanced load.

  9. Influence of load type on power factor and harmonic composition of three-phase rectifier current

    Science.gov (United States)

    Nikolayzin, N. V.; Vstavskaya, E. V.; Konstantinov, V. I.; Konstantinova, O. V.

    2018-05-01

    This article is devoted to research of the harmonic composition of the three-phase rectifier current consumed when it operates with different types of load. The results are compared with Standard requirements.

  10. Efficiency analysis on a two-level three-phase quasi-soft-switching inverter

    DEFF Research Database (Denmark)

    Geng, Pan; Wu, Weimin; Huang, Min

    2013-01-01

    When designing an inverter, an engineer often needs to select and predict the efficiency beforehand. For the standard inverters, plenty of researches are analyzing the power losses and also many software tools are being used for efficiency calculation. In this paper, the efficiency calculation...... for non-conventional inverters with special shoot-through state is introduced and illustrated through the analysis on a special two-level three-phase quasi-soft-switching inverter. Efficiency comparison between the classical two-stage two-level three-phase inverter and the two-level three-phase quasi......-soft-switching inverter is carried out. A 10 kW/380 V prototype is constructed to verify the analysis. The experimental results show that the efficiency of the new inverter is higher than that of the traditional two-stage two- level three-phase inverter....

  11. Design of three-phased SPWM based on AT89C52

    Science.gov (United States)

    Wu, Xiaorui

    2018-05-01

    According to the AT89C52 and the area equivalent principle, a three phase SPWM algorithm based on the 8 bit single chip is obtained. Through computer programming, three-phase SPWM wave generated by a single chip microcomputer is applied to the circuit of the static reactive power generator. The result shows that this method is feasible and can reduce the cost of SVG.

  12. MODELING OF SYMMETRIC THREE-PHASE ASYNCHRONOUS ELECTRIC MOTOR IN ASYMMETRIC CONNECTION TO NETWORK

    Directory of Open Access Journals (Sweden)

    V. I. Lukovnikov

    2005-01-01

    Full Text Available The paper shows how to solve the problem concerning reveal of changes in mathematical models and electric parameters of symmetric three-phase short-circuited asynchronous electric motors in case of their connection to single- or two-phase network in comparison with their connection to three-phase network. The uniform methodological approach permitting to generalize the known data and receive new results is offered in the paper.

  13. The analysis of magnesium oxide hydration in three-phase reaction system

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Xiaojia; Guo, Lin; Chen, Chen; Liu, Quan; Li, Tie; Zhu, Yimin, E-mail: ntp@dlmu.edu.cn

    2014-05-01

    In order to investigate the magnesium oxide hydration process in gas–liquid–solid (three-phase) reaction system, magnesium hydroxide was prepared by magnesium oxide hydration in liquid–solid (two-phase) and three-phase reaction systems. A semi-empirical model and the classical shrinking core model were used to fit the experimental data. The fitting result shows that both models describe well the hydration process of three-phase system, while only the semi-empirical model right for the hydration process of two-phase system. The characterization of the hydration product using X-Ray diffraction (XRD) and scanning electron microscope (SEM) was performed. The XRD and SEM show hydration process in the two-phase system follows common dissolution/precipitation mechanism. While in the three-phase system, the hydration process undergo MgO dissolution, Mg(OH){sub 2} precipitation, Mg(OH){sub 2} peeling off from MgO particle and leaving behind fresh MgO surface. - Graphical abstract: There was existence of a peeling-off process in the gas–liquid–solid (three-phase) MgO hydration system. - Highlights: • Magnesium oxide hydration in gas–liquid–solid system was investigated. • The experimental data in three-phase system could be fitted well by two models. • The morphology analysis suggested that there was existence of a peel-off process.

  14. Single phase inverter for a three phase power generation and distribution system

    Science.gov (United States)

    Lindena, S. J.

    1976-01-01

    A breadboard design of a single-phase inverter with sinusoidal output voltage for a three-phase power generation and distribution system was developed. The three-phase system consists of three single-phase inverters, whose output voltages are connected in a delta configuration. Upon failure of one inverter the two remaining inverters will continue to deliver three-phase power. Parallel redundancy as offered by two three-phase inverters is substituted by one three-phase inverter assembly with high savings in volume, weight, components count and complexity, and a considerable increase in reliability. The following requirements must be met: (1) Each single-phase, current-fed inverter must be capable of being synchronized to a three-phase reference system such that its output voltage remains phaselocked to its respective reference voltage. (2) Each single-phase, current-fed inverter must be capable of accepting leading and lagging power factors over a range from -0.7 through 1 to +0.7.

  15. Design and implementation of predictive current control of three-phase PWM rectifier using space-vector modulation (SVM)

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Gaubert, Jean-Paul; Krim, Fateh

    2010-01-01

    This paper is concerned with the design and implementation of current control of three-phase PWM rectifier based on predictive control strategy. The proposed predictive current control technique operates with constant switching frequency, using space-vector modulation (SVM). The main goal of the designed current control scheme is to maintain the dc-bus voltage at the required level and to achieve the unity power factor (UPF) operation of the converter. For this purpose, two predictive current control algorithms, in the sense of deadbeat control, are developed for direct controlling input current vector of the converter in the stationary α-β and rotating d-q reference frame, respectively. For both predictive current control algorithms, at the beginning of each switching period, the required rectifier average voltage vector allowing the cancellation of both tracking errors of current vector components at the end of the switching period, is computed and applied during a predefined switching period by means of SVM. The main advantages of the proposed predictive current control are that no need to use hysteresis comparators or PI controllers in current control loops, and constant switching frequency. Finally, the developed predictive current control algorithms were tested both in simulations and experimentally, and illustrative results are presented here. Results have proven excellent performance in steady and transient states, and verify the validity of the proposed predictive current control which is compared to other control strategies.

  16. Discontinuous PWM Modulation Strategy with Circuit-Level Decoupling Concept of Three-Level Neutral-Point Clamped (NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2013-01-01

    inverters, but also reduces the switching loss of the inverter along with an inherent neutral point (NP) voltage control. Based on a circuit-level decoupling concept, the NPC inverter can be decoupled into two three-level Buck converters in every defined operating section, and thereby the controller design...... can be reduced by one third. In order to explain the operation of this topology properly, the decoupling principle including the driving signal synthesis and the NP potential variation are analyzed in detail in this paper. Finally the viability and performance of the proposed modulation scheme...

  17. Power Capability Investigation Based on Electrothermal Models of Press-pack IGBT Three-Level NPC and ANPC VSCs for Multimegawatt Wind Turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2012-01-01

    to provide reactive power support as an ancillary service. For multimegawatt full-scale wind turbines, power capability depends on converter topology and semiconductor switch technology. As power capability limiting factors, switch current, semiconductor junction temperature, and converter output voltage...... are addressed in this study for the three-level neutral-point-clamped voltage source converter (3L-NPC-VSC) and 3L Active NPC VSC (3L-ANPC-VSC) with press-pack insulated gate bipolar transistors employed as a grid-side converter. In order to investigate these VSCs' power capabilities under various operating...... conditions with respect to these limiting factors, a power capability generation algorithm based on the converter electrothermal model is developed. Built considering the VSCs' operation principles and physical structure, the model is validated by a 2 MV·A single-phase 3L-ANPC-VSC test setup. The power...

  18. A new method for the experimental determination of three-phase relative permeabilities

    International Nuclear Information System (INIS)

    Perez Carrillo, Edgar Ricardo; Jose Francisco Zapata Arango; Santos Santos, Nicolas

    2008-01-01

    Petroleum reservoirs under primary, secondary or tertiary recovery processes usually experience simultaneous flow of three fluids phases (oil, water and gas). Reports on some mathematical models for calculating three-phase relative permeability are available in the Literature. Nevertheless, many of these models were designed based on certain experimental conditions and reservoir rocks and fluids. Therefore, special care has to be taken when applying them to specific reservoirs. At the laboratory level, three-phase relative permeability can be calculated using experimental unsteady-state or steady state methodologies. This paper proposes an unsteady-state methodology to evaluate three-phase relative permeability using the equipment available at the petrophysical analysis Laboratory of the Instituto Colombiano del Petroleo (ICP) of Ecopetrol S.A. Improvements to the equipment were effected in order to achieve accuracy in the unsteady-state measurement of three-phase relative permeability. The target of improvements was directed toward to the attainment of two objectives:1) the modification of the equipment to obtain more reliable experimental data and 2) the appropriate interpretation of the data obtained. Special attention was given to the differential pressure and uncertainty measurement in the determination of fluid saturation in the rock samples. Three experiments for three-phase relative permeability were conducted using a sample A and reservoir rock from the Colombian Foothills. Fluid tests included the utilization of synthetic brine, mineral oil, reservoir crude oil and nitrogen. Two runs were conducted at the laboratory conditions while one run was conducted at reservoir conditions. Experimental results of these tests were compared using 16 mathematical models of three-phase relative permeability. For the three-phase relative permeability to oil, the best correlations between experimental data and tests using Blunt, Hustad Hasen, and Baker's models were

  19. A Physical Model for Three-Phase Compaction in Silicic Magma Reservoirs

    Science.gov (United States)

    Huber, Christian; Parmigiani, Andrea

    2018-04-01

    We develop a model for phase separation in magma reservoirs containing a mixture of silicate melt, crystals, and fluids (exsolved volatiles). The interplay between the three phases controls the dynamics of phase separation and consequently the chemical and physical evolution of magma reservoirs. The model we propose is based on the two-phase damage theory approach of Bercovici et al. (2001, https://doi.org/10.1029/2000JB900430) and Bercovici and Ricard (2003, https://doi.org/10.1046/j.1365-246X.2003.01854.x) because it offers the leverage of considering interface (in the macroscopic limit) between phases that can deform depending on the mechanical work and phase changes taking place locally in the magma. Damage models also offer the advantage that pressure is defined uniquely to each phase and does not need to be equal among phases, which will enable us to consider, in future studies, the large capillary pressure at which fluids are mobilized in mature, crystal-rich, magma bodies. In this first analysis of three-phase compaction, we solve the three-phase compaction equations numerically for a simple 1-D problem where we focus on the effect of fluids on the efficiency of melt-crystal separation considering the competition between viscous and buoyancy stresses only. We contrast three sets of simulations to explore the behavior of three-phase compaction, a melt-crystal reference compaction scenario (two-phase compaction), a three-phase scenario without phase changes, and finally a three-phase scenario with a parameterized second boiling (crystallization-induced exsolution). The simulations show a dramatic difference between two-phase (melt crystals) and three-phase (melt-crystals-exsolved volatiles) compaction-driven phase separation. We find that the presence of a lighter, significantly less viscous fluid hinders melt-crystal separation.

  20. The comparing results of carcinoma between three-phase and delayed whole body bone scan

    International Nuclear Information System (INIS)

    Si Hongwei; Li Xianfeng

    2004-01-01

    Purpose: Three phase bone scan is an imaging technology in nuclear medicine, which composed of blood flow phase, blood pool phase and delayed phase and the last one is often performed in routine works in department of nuclear medicine. The purpose of this study is to evaluate the merit of three-phase bone scan.Methods: In this study, we chose 54 patients who were having an regional pain which caused by benign or malignant carcinoma that diagnosed by CT, X-ray, ECT, MRI or other examinations. The imaging were acquired simultaneously from both anterior and posterior views, after a bolus injection of 1110 MBq technetium-99m-labelled methylene diphosphonate (MDP), blood phase contains 20 frame sand 3 seconds per frame, blood pool phase contains 5 frames and 1 minute per frame, delayed phase was performed 2.5 hour later. According to the results of three-phase bone scan, the patients were divided into 2 groups: normal and abnormal groups. The abnormal group includes early phase positive,delay positive and all three phase positive sets. The comparing among the 3 sets were analyzed by chi-square test and other statistic means.Results: There were 54 patients who had suffered lung cancer, breast cancer and other cancer,involved in this study, 34 males and 20 females, ranged age 17 to 88 years, were normal in 15 cases,positive in 22 cases, the results in delayed phase were positive in 9 cases, blood flow and blood pool phase showed blood flow changes in 4 cases and soft tissue tumors were seen in 4 cases. Three phase bone scan was more sensitive than delayed whole body bone scan in detecting the abnormal sites (p 0.05) The sensitivity of detecting tumors in blood flow and blood pool phase,delayed phase were respectively lower than in three phase bone scan (p<0.001).Conclusion: It is more sensitivity of detecting tumor lesions in three phase bone scan than in delayed phase whole body bone scan and the changes of blood flow and soft tissue can be seen in three phase bone scan

  1. The semiquantitative three-phase bone scintigraphy on hemiplegic patients with earlier complex regional pain syndrome

    International Nuclear Information System (INIS)

    Li Fang; Liu Xingdang; Lu Zhihui; Liu Congjin

    2010-01-01

    Objective: To investigate the difference between the early phases and delay phase of three-phase bone scintigraphy on hemiplegic patients with earlier complex regional pain syndrome (CRPS). Methods: Twenty-nine stroke patients with hemiplegia complicating CRPS received three-phase bone scintigraphy after intravenous injection of 99 Tc m -methylene diphosphonate (MDP). The region of interest (ROI) technique was used to obtain the radioactive counts of involved joints and contralateral sites on wrists, metacarpophalangeal, proximal interphalangeal and distal interphalangeal joints. The total counts of these four sites in each patient were then obtained and the total uptake ratios of involved joints/contralateral joints for each phase were calculated to compare the difference among the three phases. Wilcoxon test and ANOVA were used in data analyses. Results: The involved joints of hemiplegic side displayed higher tracer uptake. There were significant differences of the radioactive counts between involved joints and uninvolved ones in the perfusion, pool and delay phase (Wilcoxon test, Z: -4.73 to -2.10, P<0.05). There was no significant difference of total uptake ratios of involved joints/contralateral joints among the three phases (ANOVA, F = 0. 807, P < 0.05). Conclusions: Due to higher bone seeking agent accumulation on three-phase bone scintigraphy, both early phases and delay phase imaging showed similar value in stroke patients with hemiplegia complicating earlier CRPS. (authors)

  2. Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

    Directory of Open Access Journals (Sweden)

    Ramesh Daravath

    2017-04-01

    Full Text Available Induction machines are the most commonly used industrial drives for variety of applications. It has been estimated that induction motors consumes approximately 50 of all the electric energy generated. Further in the area of renewable energy sources such as wind or bio-mass energy induction machines have been found suitable for functioning as generators. In this context it may be mentioned that a star-delta switching is common for the starting of three-phase induction motor. Now it is proposed to use this star-delta switching for energy conservation of induction machines i.e. at times of reduced loads the machine switched back to star connection. Using a three-phase 400 V 50 Hz 4-pole induction machine it has been demonstrated that the star-delta switching of stator winding of three-phase induction machine motor generator operations reconnected in star at suitable reduced loads with a switching arrangement can result in improved efficiency and power factor as compared to a fixed delta or star connection. The predetermined values along with the experimental results have also been presented in this report. A simulation program has been developed for the predetermination of performance of the three-phase induction machine using exact equivalent circuit. A case study on a 250 kW 400 V 4-pole three-phase induction machine operated with different load cycles reveals the significant real and reactive power savings that could be obtained in the present proposal.

  3. Energy Demodulation Algorithm for Flow Velocity Measurement of Oil-Gas-Water Three-Phase Flow

    Directory of Open Access Journals (Sweden)

    Yingwei Li

    2014-01-01

    Full Text Available Flow velocity measurement was an important research of oil-gas-water three-phase flow parameter measurements. In order to satisfy the increasing demands for flow detection technology, the paper presented a gas-liquid phase flow velocity measurement method which was based on energy demodulation algorithm combing with time delay estimation technology. First, a gas-liquid phase separation method of oil-gas-water three-phase flow based on energy demodulation algorithm and blind signal separation technology was proposed. The separation of oil-gas-water three-phase signals which were sampled by conductance sensor performed well, so the gas-phase signal and the liquid-phase signal were obtained. Second, we used the time delay estimation technology to get the delay time of gas-phase signals and liquid-phase signals, respectively, and the gas-phase velocity and the liquid-phase velocity were derived. At last, the experiment was performed at oil-gas-water three-phase flow loop, and the results indicated that the measurement errors met the need of velocity measurement. So it provided a feasible method for gas-liquid phase velocity measurement of the oil-gas-water three-phase flow.

  4. Compositional modeling of three-phase flow with gravity using higher-order finite element methods

    KAUST Repository

    Moortgat, Joachim

    2011-05-11

    A wide range of applications in subsurface flow involve water, a nonaqueous phase liquid (NAPL) or oil, and a gas phase, such as air or CO2. The numerical simulation of such processes is computationally challenging and requires accurate compositional modeling of three-phase flow in porous media. In this work, we simulate for the first time three-phase compositional flow using higher-order finite element methods. Gravity poses complications in modeling multiphase processes because it drives countercurrent flow among phases. To resolve this issue, we propose a new method for the upwinding of three-phase mobilities. Numerical examples, related to enhanced oil recovery and carbon sequestration, are presented to illustrate the capabilities of the proposed algorithm. We pay special attention to challenges associated with gravitational instabilities and take into account compressibility and various phase behavior effects, including swelling, viscosity changes, and vaporization. We find that the proposed higher-order method can capture sharp solution discontinuities, yielding accurate predictions of phase boundaries arising in computational three-phase flow. This work sets the stage for a broad extension of the higher-order methods for numerical simulation of three-phase flow for complex geometries and processes.

  5. Coordinated control of three-phase AC and DC type EV–ESSs for efficient hybrid microgrid operations

    International Nuclear Information System (INIS)

    Rahman, Md Shamiur; Hossain, M.J.; Lu, Junwei

    2016-01-01

    Highlights: • A coordinated control is proposed for three-phase AC and DC type electric vehicles. • A four-quadrant interlinking converter is designed for hybrid microgrid operations. • Concurrent real irradiation data and commercial load profile are used for testing. • Unbalanced scenario due to single-phase electric vehicle charging is considered. • Improved AC and DC bus voltages and frequency regulations are achieved. - Abstract: This paper presents a three-layered coordinated control to incorporate three-phase (3P) alternating current (AC) and direct current (DC) type electric vehicle energy storage systems (EV–ESSs) for improved hybrid AC/DC microgrid operations. The first layer of the algorithm ensures DC subgrid management by regulating the DC bus voltage and DC side power management. The second and third layer manages AC subgrid by regulating the AC bus voltage and the frequency by managing reactive and active power respectively. The multi-layered coordination is embedded into the microgrid central controller (MGCC) which controls the interlinking controller in between AC and DC microgrid and the interfacing controllers of the participating electric vehicles (EVs) and distributed generation (DG) units. The whole system is designed in MATLAB/SIMULINK® environment resembling the under construction microgrid at Griffith University, Australia. Extensive case studies are performed using real life irradiation data and commercial loads of the campus buildings. Impacts of homogeneous and heterogeneous single-phase EV charging are investigated to observe both balanced and unbalanced scenarios. Synchronization during the transition from the islanded to grid-tied mode is tested considering a contingency situation. From the comparative simulation results it is evident that the proposed controller exhibits effective, reliable and robust performance for all the cases.

  6. Three-phase distillation. Simulation and application to the separation of fermentation products

    Energy Technology Data Exchange (ETDEWEB)

    Pucci, A; Mikitenko, P; Asselineau, L

    1986-01-01

    In recent years, most of the simulation methods proposed for solving distillation problems in which three-phase distillation occurs use a Newton-Raphson or a comparable approach which requires an initial estimate of variables close enough to the final answer. A plate-to-plate calculation which is more likely to converge on the solution is presented here. The phase equilibria are represented by the NRTL model. The position of three-phase stages is solved automatically. Another three-phase distillation program operating at infinite reflux first supplies the location of feeds and/or sidestreams and computes the minimum number of stages for a given separation. An application of the proposed method is illustrated by the rectification of butanol-acetone fermentation products. The calculated results are in good agreement with the experimental data obtained from the operation of a laboratory glass-plate-type column. 19 references, 8 figures, 1 table.

  7. Numerical Simulation on Flow Field of Oilfield Three-Phase Separator

    Directory of Open Access Journals (Sweden)

    Yong-tu Liang

    2013-01-01

    Full Text Available The conventional measurement method can no longer guarantee the accuracy requirement after the oilfield development entering high water cut stage, due to the water content and gas phase in the flow. In order to overcome the impact of measurement deviation the oilfield production management, the flow field of three-phase separator is studied numerically in this paper using Fluent 6.3.26. Taking into consideration the production situation of PetroChina Huabei Oilfield and the characteristics of three-phase separator, the effect of internal flow status as well as other factors such as varying flow rate, gas fraction, and water content on the separation efficiency is analyzed. The results show that the separation efficiencies under all operation conditions are larger than 95%, which satisfy the accuracy requirement and also provide the theoretical foundation for the application of three-phase separators at oilfields.

  8. State-of-Charge Balancing Control of a Modular Multilevel Converter with an Integrated Battery Energy Storage

    Directory of Open Access Journals (Sweden)

    Hui Liang

    2018-04-01

    Full Text Available With the fast development of the electric vehicle industry, the reuse of second-life batteries in vehicles are becoming more attractive, however, both the state-of-charge (SOC inconsistency and the capacity inconsistency of second-life batteries have limits in their utilization. This paper focuses on the second-life batteries applied battery energy storage system (BESS based on modular multilevel converter (MMC. By analyzing the power flow characteristics among all sources within the MMC-BESS, a three-level SOC equilibrium control strategy aiming to battery capacity inconsistency is proposed to balance the energy of batteries, which includes SOC balance among three-phase legs, SOC balance between the upper and lower arms of each phase, and SOC balance of submodules within each arm. In battery charging and discharging control, by introducing power regulations based on battery capacity proportion of three-phase legs, capacity deviation between the upper and lower’s arm, and the capacity coefficient of the submodule into the SOC feedback control loop, SOC balance of all battery modules is accomplished, thus effectively improving the energy utilization of second-life battery energy storage system. Finally, the effectiveness and feasibility of the proposed methods are verified by results obtained from simulations and the experimental platform.

  9. Imaging phase holdup distribution of three phase flow systems using dual source gamma ray tomography

    International Nuclear Information System (INIS)

    Varma, Rajneesh; Al-Dahhan, Muthanna; O'Sullivan, Joseph

    2008-01-01

    Full text: Multiphase reaction and process systems are used in abundance in the chemical and biochemical industry. Tomography has been successfully employed to visualize the hydrodynamics of multiphase systems. Most of the tomography methods (gamma ray, x-ray and electrical capacitance and resistance) have been successfully implemented for two phase dynamic systems. However, a significant number of chemical and biochemical systems consists of dynamic three phases. Research effort directed towards the development of tomography techniques to image such dynamic system has met with partial successes for specific systems with applicability to limited operating conditions. A dual source tomography scanner has been developed that uses the 661 keV and 1332 keV photo peaks from the 137 Cs and 60 Co for imaging three phase systems. A new approach has been developed and applied that uses the polyenergetic Alternating Minimization (A-M) algorithm, developed by O'Sullivan and Benac (2007), for imaging the holdup distribution in three phases' dynamic systems. The new approach avoids the traditional post image processing approach used to determine the holdup distribution where the attenuation images of the mixed flow obtained from gamma ray photons of two different energies are used to determine the holdup of three phases. In this approach the holdup images are directly reconstructed from the gamma ray transmission data. The dual source gamma ray tomography scanner and the algorithm were validated using a three phase phantom. Based in the validation, three phase holdup studies we carried out in slurry bubble column containing gas liquid and solid phases in a dynamic state using the dual energy gamma ray tomography. The key results of the holdup distribution studies in the slurry bubble column along with the validation of the dual source gamma ray tomography system would be presented and discussed

  10. Single-phase DECT with VNCT compared with three-phase CTU in patients with haematuria

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jung Jae; Park, Byung Kwan; Kim, Chan Kyo [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-10-15

    To retrospectively evaluate the diagnostic performance of single-phase dual-energy CT (DECT) with virtual non-contrast CT (VNCT) compared with three-phase CT urography (CTU) in patients with haematuria. A total of 296 patients underwent three-phase CTU (NCT at 120 kVp; nephrographic phase and excretory phase DECTs at 140 kVp and 80 kVp) owing to haematuria. Diagnostic performances of CT scans were compared for detecting urothelial tumours and urinary stones. Dose-length product (DLP) was compared in relation to single-phase DECT and three-phase CTU Dose-length product (DLP) was compared in relation to single-phase DECT and three-phase CTU. Sensitivity and specificity for tumour were 95 % (19/20) and 98.9 % (273/276) on CTU, 95 % (19/20) and 98.2 % (271/276) on nephrographic phase DECT, and 90 % (18/20) and 98.2 % (271/276) on excretory phase DECT (P > 0.1). Of the 148 stones detected on NCT, 108 (73 %) and 100 (67.6 %) were detected on nephrographic phase and excretory phase VNCTs, respectively. The mean size of stones undetected on nephrographic and excretory VNCTs was measured as 1.5 ± 0.5 mm and 1.6 ± 0.6 mm, respectively. The mean DLPs of three-phase CTU, nephrographic phase DECT and excretory phase DECT were 1076 ± 248 mGy . cm, 410 ± 98 mGy . cm, and 360 ± 87 mGy . cm, respectively (P < 0.001). Single-phase DECT has a potential to replace three-phase CTU for detecting tumours with a lower radiation dose. (orig.)

  11. A Fast-Processing Modulation Strategy for Three-Phase Four-Leg Neutral-Point-Clamped Inverter Based on the Circuit-Level Decoupling Concept

    DEFF Research Database (Denmark)

    Ghoreishy, Hoda; Zhang, Zhe; Thomsen, Ole Cornelius

    2012-01-01

    In this paper, a modulation strategy based on the circuit-level decoupling concept is proposed and investigated for the three-level four-leg neutral-point-clamped (NPC) inverter,with the aim of delivering power to all sorts of loads, linear/nonlinear and balanced/unbalanced. By applying the propo......In this paper, a modulation strategy based on the circuit-level decoupling concept is proposed and investigated for the three-level four-leg neutral-point-clamped (NPC) inverter,with the aim of delivering power to all sorts of loads, linear/nonlinear and balanced/unbalanced. By applying...... the proposed modulation strategy, the four-leg NPC inverter can be decoupled into three three-level Buck converters in each defined operating section. This makes the controller design much simpler compared to the conventional four-leg NPC inverter controllers. Also, this technique can be implemented...

  12. Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; He, Ran; Jian, Jiamin

    2016-01-01

    Eliminating the leakage current is one of the most important issues for transformerless three phase photovoltaic (PV) systems. In this paper, the leakage current elimination of a three-phase four-leg PV inverter is investigated. With the common mode loop model established, the generation mechanism...... of the leakage current is clearly identified. Different typical carrier-based modulation methods and their corresponding common mode voltages are discussed. A new modulation strategy with Boolean logic function is proposed to achieve the constant common mode voltage for the leakage current reduction. Finally...

  13. High frequency three-phase PWM grid connected drive using silicon-carbide switches

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Pedersen, Jacob Lykke; Nymand, Morten

    2016-01-01

    This paper presents controller design procedure for a fully silicon-carbide (SiC) based three-phase grid-connected PWM drive. The influence of the feedforward compensation for the presented setup is studied and the transfer function of the system with feedforward is derived and compared with the ......This paper presents controller design procedure for a fully silicon-carbide (SiC) based three-phase grid-connected PWM drive. The influence of the feedforward compensation for the presented setup is studied and the transfer function of the system with feedforward is derived and compared...

  14. Model and Frequency Control for Three-Phase Wireless Power Transfer System

    Directory of Open Access Journals (Sweden)

    Chenyang Xia

    2016-01-01

    Full Text Available In order to the eliminate the “dead spot” in the traditional three-phase wireless power transfer (WPT system, a three-phase WPT system with an asymmetric magnetic circuit is presented in this paper. Additionally, mathematical model of the system is established and the system parameters are optimized. Based on the fact that the resonant frequency and efficiency are greatly varied with the load, a method based on impedance conversion is further proposed to improve the frequency stability and system efficiency. Finally, simulation and experimental results show that the proposed method is reliable and feasible to eliminate the “dead spot.”

  15. Four-branch Star Hybrid Power Filter for Three-phase Four-wire Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Rodriguez, Pedro

    2008-01-01

    and derives fundamental concepts about the control of the resulting hybrid power filter. From this analysis, a specifc implementation of a three-phase four-wire hybrid power filter is presented as an illustrative application of the filtering topology. An extensive evaluation using simulation and experimental......This paper presents a new concept for filtering current harmonics in three-phase four-wire networks. The four-branch star (FBS) filtering topology presented in this work is characterized by a particular layout consisting of single-phase inductances and capacitors. Via this layout, a power filter...

  16. Modeling and control of three phase rectifier with electronic smoothing inductor

    DEFF Research Database (Denmark)

    Singh, Yash Veer; Rasmussen, Peter Omand; Andersen, Torben Ole

    2011-01-01

    This paper presents a simple, direct method for deriving the approximate, small-signal, average model and control strategy for three-phase diode bridge rectifier operating with electronic smoothing technique. Electronic smoothing inductor (ESI) performs the function of an inductor that has...... controlled variable impedance. This increases power factor (PF) and reduces total harmonic distortions (THDs) in mains current. The ESI based rectifier enables compact and cost effective design of three phase electric drive as size of passive components is reduced significantly. In order to carry out...

  17. Three-phase multilevel inverter configuration for open-winding high power application

    DEFF Research Database (Denmark)

    Sanjeevikumar, Padmanaban; Blaabjerg, Frede; Wheeler, Patrick William

    2015-01-01

    This paper work exploits a new dual open-winding three-phase multilevel inverter configuration suitable for high power medium-voltage applications. Modular structure comprised of standard three-phase voltage source inverter (VSI) along with one additional bi-directional semiconductor device (MOSFET...... for implementation purpose. Proposed dual-inverter configuration generates multilevel outputs with benefit includes reduced THD and dv/dt in comparison to other dual-inverter topologies. Complete model of the multilevel ac drive is developed with simple MSCFM modulation in Matlab/PLECs numerical software...

  18. Three-Phase Modulated Pole Machine Topologies Utilizing Mutual Flux Paths

    DEFF Research Database (Denmark)

    Washington, Jamie G.; Atkinson, Glynn J.; Baker, Nick J.

    2012-01-01

    This paper discusses three-phase topologies for modulated pole machines (MPMs). The authors introduce a new threephase topology, which takes advantage of mutual flux paths; this is analyzed using 3-D finite-element methods and compared to a three-phase topology using three single-phase units...... stacked axially. The results show that the new “combined-phase MPM” exhibits a greater torque density, while offering a reduction in the number of components. The results obtained from two prototypes are also presented to verify the concept; the results show that the “combined-phase” machine could provide...

  19. A new on-chip all-digital three-phase full-bridge dc/ac power inverter with feedforward and frequency control techniques.

    Science.gov (United States)

    Chen, Jiann-Jong; Kung, Che-Min

    2010-09-01

    The communication speed between components is far from satisfactory. To achieve high speed, simple control system configuration, and low cost, a new on-chip all-digital three-phase dc/ac power inverter using feedforward and frequency control techniques is proposed. The controller of the proposed power inverter, called the shift register, consists of six-stage D-latch flip-flops with a goal of achieving low-power consumption and area efficiency. Variable frequency is achieved by controlling the clocks of the shift register. One advantage regarding the data signal (D) and the common clock (CK) is that, regardless of the phase difference between the two, all of the D-latch flip-flops are capable of delaying data by one CK period. To ensure stability, the frequency of CK must be six times higher than that of D. The operation frequency of the proposed power inverter ranges from 10 Hz to 2 MHz, and the maximum output loading current is 0.8 A. The prototype of the proposed circuit has been fabricated with TSMC 0.35 μm 2P4M CMOS processes. The total chip area is 2.333 x 1.698 mm2. The three-phase dc/ac power inverter is applicable in uninterrupted power supplies, cold cathode fluorescent lamps, and motors, because of its ability to convert the dc supply voltage into the three-phase ac power sources.

  20. Three-phase Power Flow Calculation of Low Voltage Distribution Network Considering Characteristics of Residents Load

    Science.gov (United States)

    Wang, Yaping; Lin, Shunjiang; Yang, Zhibin

    2017-05-01

    In the traditional three-phase power flow calculation of the low voltage distribution network, the load model is described as constant power. Since this model cannot reflect the characteristics of actual loads, the result of the traditional calculation is always different from the actual situation. In this paper, the load model in which dynamic load represented by air conditioners parallel with static load represented by lighting loads is used to describe characteristics of residents load, and the three-phase power flow calculation model is proposed. The power flow calculation model includes the power balance equations of three-phase (A,B,C), the current balance equations of phase 0, and the torque balancing equations of induction motors in air conditioners. And then an alternating iterative algorithm of induction motor torque balance equations with each node balance equations is proposed to solve the three-phase power flow model. This method is applied to an actual low voltage distribution network of residents load, and by the calculation of three different operating states of air conditioners, the result demonstrates the effectiveness of the proposed model and the algorithm.

  1. Three-phase scintigraphy in epicondylitis of the lateral lower humerus

    Energy Technology Data Exchange (ETDEWEB)

    Koppers, B.; Riel, K.

    1982-08-01

    Ten patients with tennis elbow were examined by three-phase scintigraphy, using sup(99m)Tc-MDP. In agreement with the histological findings of H. Schneider (14), there was no uptake during the perfusion and soft tissue phase. In the phase, there was focal bone uptake in one patient only.

  2. Three-phase scintigraphy in epicondylitis of the lateral lower humerus

    International Nuclear Information System (INIS)

    Koppers, B.; Riel, K.; Technische Univ. Muenchen

    1982-01-01

    Ten patients with tennis elbow were examined by three-phase scintigraphy, using sup(99m)Tc-MDP. In agreement with the histological findings of H. Schneider (14), there was no uptake during the perfusion and soft tissue phase. In the phase, there was focal bone uptake in one patient only. (orig.) [de

  3. THREE-PHASE ENERGY SUPPLY SYSTEMS SIMULATION FOR THE TOTAL POWER LOSSES COMPONENTS ASSESSMENT

    Directory of Open Access Journals (Sweden)

    D.V. Tugay

    2016-09-01

    Full Text Available Purpose. The goal is to optimize a structure of Matlab-model of the three-phase energy supply system with power active filter. The mathematical model that describes the energy supply system modes of operation which contains additional losses is proposed. Methodology. We have applied concepts of the electrical circuits theory, mathematical modeling elements based on linear algebra and vector calculus, mathematical simulation in Matlab package. Results. We have developed two models of three-phase energy supply system. The first one is based on a vector representation, and the second one on the matrix representation of energy processes. Using these models we have solved the problem of maintaining unchanged the average useful power for 279 cases of energy supply system modes of operation. Originality. We have developed methods of mathematical analysis of a three-phase energy supply systems with polyharmonic voltages and currents in the symmetric and asymmetric modes. Practical value. We have created Matlab-model of a three-phase energy supply system with automated calculation of a correction factor. It allows reducing more than one order the time for energy processes elucidation in multiphase systems.

  4. Active Damping Control Methods for Three-Phase Slim DC-link Drive System

    DEFF Research Database (Denmark)

    Yang, Feng; Wang, Dong; Blaabjerg, Frede

    2017-01-01

    for stabilizing such slim dc-link drives together with the benefit of low cost and high flexibility. This paper gives an overview of the state-of-the-art active damping methods for the three-phase slim dc-link drive. The main pros and cons of each method are identified. The theoretical comparison is validated...

  5. Development of an expert system for three-phase induction motors

    NARCIS (Netherlands)

    Sprangers, R.L.J.; Motoasca, T.E.; Lomonova, E.

    2012-01-01

    This work presents the design of an Expert System (Motor Design Software Tool - MDST) that will be used for design and analysis of three-phase induction motors. A suitable selection between numerous models and parameter calculation methods provided by literature is made and discussed. The models are

  6. Three-Phase Grid-Connected of Photovoltaic Generator Using Nonlinear Control

    DEFF Research Database (Denmark)

    Yahya, A.; El Fadil, H.; Guerrero, Josep M.

    2014-01-01

    This paper proposes a nonlinear control methodology for three phase grid connected of PV generator. It consists of a PV arrays; a voltage source inverter, a grid filter and an electric grid. The controller objectives are threefold: i) ensuring the Maximum power point tracking (MPPT) in the side...... stability analysis and simulation results that the proposed controller meets all the objectives....

  7. A Smart Current Modulation Scheme for Harmonic Reduction in Three- Phase Motor Drive Applications

    DEFF Research Database (Denmark)

    Davari, Pooya; Zare, Firuz; Blaabjerg, Frede

    2015-01-01

    Electric motor-driven systems consume considerable amount of the global electricity. Majority of three-phase motor drives are equipped with conventional diode rectifier and passive harmonic mitigation, being witnessed as the main source in generating input current harmonics. While many active har...

  8. A Multipulse Pattern Modulation Scheme for Harmonic Mitigation in Three-Phase Multimotor Drives

    DEFF Research Database (Denmark)

    Davari, Pooya; Yang, Yongheng; Zare, Firuz

    2016-01-01

    , which thus deteriorates the power grid quality and also lowers the conversion efficiency. Both degradations are apt to occur in motor drive applications. At present, many industrial drives are equipped with three-phase diode rectifiers and employ passive filtering techniques on the AC or DC side...

  9. Optimal Power Flow in three-phase islanded microgrids with inverter interfaced units

    DEFF Research Database (Denmark)

    Sanseverino, Eleonora Riva; Quang, Ninh Nguyen; Di Silvestre, Maria Luisa

    2015-01-01

    In this paper, the solution of the Optimal Power Flow (OPF) problem for three phase islanded microgrids is studied, the OPF being one of the core functions of the tertiary regulation level for an AC islanded microgrid with a hierarchical control architecture. The study also aims at evaluating the...

  10. Optimal power flow based on glow worm-swarm optimization for three-phase islanded microgrids

    DEFF Research Database (Denmark)

    Quang, Ninh Nguyen; Sanseverino, Eleonora Riva; Di Silvestre, Maria Luisa

    2014-01-01

    This paper presents an application of the Glowworm Swarm Optimization method (GSO) to solve the optimal power flow problem in three-phase islanded microgrids equipped with power electronics dc-ac inverter interfaced distributed generation units. In this system, the power injected by the distribut...

  11. A Voltage Modulated DPC Approach for Three-Phase PWM Rectifier

    DEFF Research Database (Denmark)

    Gui, Yonghao; Li, Mingshen; Lu, Jinghang

    2018-01-01

    In this paper, a voltage modulated direct power control for three-phase pulse-width modulated rectifier is proposed. With the suggested method, the differential equations describing the rectifier dynamics are changing from a linear time-varying system into a linear time-invariant one. In this way...

  12. Three Phase Six-Switch PWM Buck Rectifier with Power Factor Improvement

    DEFF Research Database (Denmark)

    Zafar Ullah Khan, M; Mohsin Naveed, M.; Hussain, Dil Muhammad Akbar

    2013-01-01

    Conventional Phase Controlled Rectifier injects low order current harmonics into the AC mains. Large size filtering components are required to attenuate these harmonics. In this paper, Three Phase Six-Switch PWM Buck Rectifier[1] is presented which operates at nearly unity power factor and provides...

  13. Predictive Duty Cycle Control of Three-Phase Active-Front-End Rectifiers

    DEFF Research Database (Denmark)

    Song, Zhanfeng; Tian, Yanjun; Chen, Wei

    2016-01-01

    This paper proposed an on-line optimizing duty cycle control approach for three-phase active-front-end rectifiers, aiming to obtain the optimal control actions under different operating conditions. Similar to finite control set model predictive control strategy, a cost function previously...

  14. Stability Improvements of an LCL-filter based Three-phase Active Rectifier

    DEFF Research Database (Denmark)

    Liserre, Marco; Dell'Aquila, Antonio; Blaabjerg, Frede

    2002-01-01

    Three-phase active rectifiers guarantee sinusoidal input currents and controllable dc voltage at the price of a high switching frequency ripple that can disturb and reduce efficiency of other EMI sensitive equipment connected to the grid. This problem could be solved choosing a high value...

  15. A laboratory grid simulator based on three-phase four-leg inverter

    DEFF Research Database (Denmark)

    Li, Fei; Wang, Xiongfei; Chen, Zhe

    2011-01-01

    This paper presents the design and implementation of a laboratory grid simulator which is used to test the grid-connected devices according to the strict standards. Three-phase four-leg inverter with direct voltage control in Natural Frame is adopted in this grid simulator, which significantly...

  16. Three-Phase Cascaded Multilevel Inverter Using Power Cells With Two Inverter Legs in Series

    NARCIS (Netherlands)

    Waltrich, G.; Barbi, I.

    2010-01-01

    In this paper, a modular three-phase multilevel inverter specially suited for electrical drive applications is proposed. Unlike the cascaded H-bridge inverter, this topology is based on power cells connected in cascade using two inverter legs in series. A detailed analysis of the structure and the

  17. A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

    International Nuclear Information System (INIS)

    Wang, Zeyu; Wang, Jianhui; Chen, Chen

    2016-01-01

    Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraint is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.

  18. A control strategy based on UTT and I CosΘ theory of three-phase ...

    African Journals Online (AJOL)

    The performance of the implemented control algorithm is evaluated in terms of power-factor correction; load balancing, neutral source current mitigation and mitigation of voltage and current harmonics, voltage sag and swell and voltage dips in a three-phase four-wire distribution system for different combination of linear and ...

  19. Three-phase boundary length in solid-oxide fuel cells: A mathematical model

    Science.gov (United States)

    Janardhanan, Vinod M.; Heuveline, Vincent; Deutschmann, Olaf

    A mathematical model to calculate the volume specific three-phase boundary length in the porous composite electrodes of solid-oxide fuel cell is presented. The model is exclusively based on geometrical considerations accounting for porosity, particle diameter, particle size distribution, and solids phase distribution. Results are presented for uniform particle size distribution as well as for non-uniform particle size distribution.

  20. Teaching Qualitative Research for Human Services Students: A Three-Phase Model

    Science.gov (United States)

    Goussinsky, Ruhama; Reshef, Arie; Yanay-Ventura, Galit; Yassour-Borochowitz, Dalit

    2011-01-01

    Qualitative research is an inherent part of the human services profession, since it emphasizes the great and multifaceted complexity characterizing human experience and the sociocultural context in which humans act. In the department of human services at Emek Yezreel College, Israel, we have developed a three-phase model to ensure a relatively…

  1. Couplings in Phase Domain Impedance Modelling of Grid-Connected Converters

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Wang, Xiongfei; Blaabjerg, Frede

    2016-01-01

    The output impedance of a power converter plays an important role in the stability assessment of the converter. The impedance can be expressed in different frames such as the stationary frame (phase domain) or in the synchronous frame (dq domain). To treat the three-phase system like a single...

  2. Three-Phase High-Power and Zero-Current-Switching OBC for Plug-In Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Cheng-Shan Wang

    2015-06-01

    Full Text Available In this paper, an interleaved high-power zero-current-switching (ZCS onboard charger (OBC based on the three-phase single-switch buck rectifier is proposed for application to plug-in electric vehicles (EVs. The multi-resonant structure is used to achieve high efficiency and high power density, which are necessary to reduce the volume and weight of the OBC. This study focuses on the border conditions of ZCS converting with a battery load, which means the variation ranges of the output voltage and current are very large. Furthermore, a novel hybrid control method combining pulse frequency modulation (PFM and pulse width modulation (PWM together is presented to ensure a driving frequency higher than 10 kHz, and this will reduce the unexpected inner resonant power flow and decrease the total harmonic distortion (THD of the input current under a light load at the end of the charging process. Finally, a prototype is established, and experiments are carried out. According to the experimental results, the conversion efficiency is higher than 93.5%, the THD about 4.3% and power factor (PF 0.98 under the maximum power output condition. Besides, a three-stage charging process is also carried out the experimental platform.

  3. Harmonic Injection-Based Power Fluctuation Control of Three-Phase PV Systems under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Nian-Cheng Zhou

    2015-02-01

    Full Text Available Unbalanced voltage will inevitably cause power and DC voltage fluctuations in a three-phase PV system. The deterioration of power quality will do great harm to the PV panels and the loads, so it is necessary to suppress the power fluctuations. This paper further explores the coefficients control strategy of PV converters under unbalanced voltage conditions, aiming to suppress power fluctuations by controlling the injection of some specific orders of current harmonics into the grid. In order to achieve this, the current reference of the PV inverter has been changed by bringing in two control coefficients, and the expression of each order of the current harmonics has been deduced. Based on the standards of PV systems, the regions from which the coefficients can be selected are determined. Then, by tuning these coefficients in the feasible regions, the output parameters (power fluctuation, current THD and odd harmonics can be controlled precisely. The model of this method is built and simulated in PSCAD/EMTDC, and as a result, it is shown that the power fluctuations can be restricted according to different power quality requirements.

  4. Energy-Regenerative Braking Control of Electric Vehicles Using Three-Phase Brushless Direct-Current Motors

    Directory of Open Access Journals (Sweden)

    Bo Long

    2013-12-01

    Full Text Available Regenerative braking provides an effective way of extending the driving range of battery powered electric vehicles (EVs. This paper analyzes the equivalent power circuit and operation principles of an EV using regenerative braking control technology. During the braking period, the switching sequence of the power converter is controlled to inverse the output torque of the three-phase brushless direct-current (DC motor, so that the braking energy can be returned to the battery. Compared with the presented methods, this technology can achieve several goals: energy recovery, electric braking, ultra-quiet braking and extending the driving range. Merits and drawbacks of different braking control strategy are further elaborated. State-space model of the EVs under energy-regenerative braking operation is established, considering that parameter variations are unavoidable due to temperature change, measured error, un-modeled dynamics, external disturbance and time-varying system parameters, a sliding mode robust controller (SMRC is designed and implemented. Phase current and DC-link voltage are selected as the state variables, respectively. The corresponding control law is also provided. The proposed control scheme is compared with a conventional proportional-integral (PI controller. A laboratory EV for experiment is setup to verify the proposed scheme. Experimental results show that the drive range of EVs can be improved about 17% using the proposed controller with energy-regeneration control.

  5. Loss and thermal redistributed modulation methods for three-level neutral-point-clamped wind power inverter undergoing Low Voltage Ride Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2012-01-01

    The three-level neutral-point-clamped (3L-NPC) converter is a promising multilevel topology in the application of mega-watts wind power generation system. However, the growing requirements by grid codes may impose high stress and even give reliability problem to this converter topology. This paper...... modulation methods, the thermal distribution in the 3L-NPC wind power inverter undergoing LVRT becomes more equal, and the junction temperature of the most stressed devices can be also relieved. Also the control ability of DC-bus neutral point potential, which is one of the crucial considerations for the 3L...

  6. The method for simultaneous extraction and back extraction in liquid three-phase system and equipment for simultaneous extraction and back extraction in liquid three-phase system

    International Nuclear Information System (INIS)

    Palyska, W.; Chmielewski, A.G.

    1992-01-01

    The method for simultaneous extraction and back extraction in liquid three-phase system has been worked out. The equipment designed for that process has been also subject of the patent. The interesting component is extracted first to intermediate phase consists of magnetic solvent keeping two extracting phases separately. The intermediate magnetic liquid has been kept in its position using a stable magnet maintained on the surface of the extraction vessel. Then the component pass from intermediate phase to the third phase as a result of back extraction. Mixing in the extraction and back extraction zones is organized by means of rotating shaft going along the whole apparatus. The extraction and back extraction processes occur simultaneously as a result of continuous flow of solvent in their zones. The single extraction back extraction facilities can be joined in larger batteries. 3 figs

  7. Fracture healing: Quantitative three-phase bone scintigraphy as a prognostic factor

    International Nuclear Information System (INIS)

    Dodig, D.; Kasal, B.; Kragic-Pranic, A.; Predic, P.

    2002-01-01

    Aim: Careful clinical examination and conventional radiography, together with other standard methods for evaluation of bone fracture healing, are frequently inconclusive. Furthermore, it is difficult to predict the complications of healing on the basis of clinical and radiographic findings only. Bone scintigraphy plays an important role in detecting bone fractures. This method is very sensitive, but not enough specific. The aim of this work was to evaluate the role of three-phase bone scintigraphy in the healing prognosis of long bone fractures. Material and Methods: We evaluated the three elements (perfusion, blood pool and static image) of three-phase bone scintigraphy in early prognosis of the course of fracture healing in patients with fractures of femur or tibia. Three-phase bone scintigraphy was performed in 73 patients. The patients were divided into 4 groups according to X-ray and clinical examination: 1) Non operated patients with stable fracture, 2) Operated patients with unstable fracture (infection), 3) Fractures with delayed union, 4) Patients with pseudoarthrosis. Using region of interest (ROI) method we compared the activity on the site of fracture with the activity on the symmetrical place in the healthy bone. The relative indices for each group of patients and for each element of three-bone scintigraphy were calculated in order to make possible the follow up of the fracture healing and to obtain data for prognosis and evaluation of possible complications. Results: The most valuable results were obtained by quantitative analysis of perfusion data immediately after trauma and 2-3 weeks later. Our results show a high diagnostic accuracy in identifying infection by perfusion scintigrams immediately after trauma. The perfusion indices obtained immediately and after 2-3 weeks could predict delayed union after the trauma. Quantitative analysis of blood pool phase gave no data of clinical significance in distinguishing various pathologies. Conclusion: Our

  8. Probabilistic Teleportation of an Arbitrary Three-Level Two-Particle State and Classical Communication Cost

    Institute of Scientific and Technical Information of China (English)

    DAIHong-Yi; KUANGLe-Man; LICheng-Zu

    2005-01-01

    We propose a scheme to probabilistically teleport an unknown arbitrary three-level two-particle state by using two partial entangled two-particle states of three-level as the quantum channel. The classical communication cost required in the ideal probabilistic teleportation process is also calculated. This scheme can be directly generalized to teleport an unknown and arbitrary three-level K-particle state by using K partial entangled two-particle states of three-level as the quantum channel.

  9. Flexible voltage support control for three-phase distributed generation inverters under grid fault

    DEFF Research Database (Denmark)

    Camacho, Antonio; Castilla, Miguel; Miret, Jaume

    2013-01-01

    Operators describe the behavior of the energy source, regulating voltage limits and reactive power injection to remain connected and support the grid under fault. On the basis that different kinds of voltage sags require different voltage support strategies, a flexible control scheme for three phase grid...... connected inverters is proposed. In three phase balanced voltage sags, the inverter should inject reactive power in order to raise the voltage in all phases. In one or two phase faults, the main concern of the distributed generation inverter is to equalize voltages by reducing the negative symmetric...... sequence and clear the phase jump. Due to system limitations, a balance between these two extreme policies is mandatory. Thus, over-voltage and undervoltage can be avoided, and the proposed control scheme prevents disconnection while achieving the desired voltage support service. The main contribution...

  10. The Design of Connection Solid Oxide Fuel Cell (SOFC) Integrated Grid with Three-Phase Inverter

    Science.gov (United States)

    Darjat; Sulistyo; Triwiyatno, Aris; Thalib, Humaid

    2018-03-01

    Fuel cell technology is a relatively new energy-saving technology that has the potential to replace conventional energy technologies. Among the different types of generation technologies, fuel cells is the generation technologies considered as a potential source of power generation because it is flexible and can be placed anywhere based distribution system. Modeling of SOFC is done by using Nernst equation. The output power of the fuel cell can be controlled by controlling the flow rate of the fuels used in the process. Three-phase PWM inverter is used to get the form of three-phase voltage which same with the grid. In this paper, the planning and design of the SOFC are connected to the grid.

  11. Three phase heat and mass transfer model for unsaturated soil freezing process: Part 2 - model validation

    Science.gov (United States)

    Zhang, Yaning; Xu, Fei; Li, Bingxi; Kim, Yong-Song; Zhao, Wenke; Xie, Gongnan; Fu, Zhongbin

    2018-04-01

    This study aims to validate the three-phase heat and mass transfer model developed in the first part (Three phase heat and mass transfer model for unsaturated soil freezing process: Part 1 - model development). Experimental results from studies and experiments were used for the validation. The results showed that the correlation coefficients for the simulated and experimental water contents at different soil depths were between 0.83 and 0.92. The correlation coefficients for the simulated and experimental liquid water contents at different soil temperatures were between 0.95 and 0.99. With these high accuracies, the developed model can be well used to predict the water contents at different soil depths and temperatures.

  12. Three-phase receiving coil of wireless power transmission system for gastrointestinal robot

    Science.gov (United States)

    Jia, Z. W.; Jiang, T.; Liu, Y.

    2017-11-01

    Power shortage is the bottleneck for the wide application of gastrointestinal (GI) robot. Owing to the limited volume and free change of orientation of the receiving set in GI trace, the optimal of receiving set is the key point to promote the transmission efficiency of wireless power transmission system. A new type of receiving set, similar to the winding of three-phase asynchronous motor, is presented and compared with the original three-dimensional orthogonal coil. Considering the given volume and the space utilization ratio, the three-phase and the three-orthogonal ones are the parameters which are optimized and compared. Both the transmission efficiency and stability are analyzed and verified by in vitro experiments. Animal experiments show that the new one could provide at least 420 mW power in volume of Φ11 × 13mm with a uniformity of 78.3% for the GI robot.

  13. A Novel Concept for Three-Phase Cascaded Multilevel Inverter Topologies

    Directory of Open Access Journals (Sweden)

    Md Mubashwar Hasan

    2018-01-01

    Full Text Available One of the key challenges in multilevel inverters (MLIs design is to reduce the number of components used in the implementation while maximising the number of output voltage levels. This paper proposes a new concept that facilitates a device count reduction technique of existing cascaded MLIs. Moreover, the proposed concept can be utilised to extend existing single phase cascaded MLI topologies to three-phase structure without tripling the number of semiconductor components and input dc-supplies as per the current practice. The new generalized concept involves two stages; namely, cascaded stage and phase generator stage. The phase generator stage is a combination of a conventional three-phase two level inverter and three bi-directional switches while the cascaded stage can employ any existing cascaded topology. A laboratory prototype model is built and extensive experimental analyses are conducted to validate the feasibility of the proposed cascaded MLI concept.

  14. Role of three-phase bone scintigraphy in therapy of lower extremity infections

    International Nuclear Information System (INIS)

    Grund, F.M.; Larson, B.W.; Sinn, L.M.; Peterson, L.R.

    1990-01-01

    This paper evaluates the ability of three-phase bone scintigraphy to predict the need for prolonged antibiotic therapy and assess results of therapy of lower extremity infections in patients with diabetes mellitus and/or peripheral vascular disease. The authors retrospectively reviewed three-phase bone scans from 39 patients who completed either 3 weeks or 3 months of oral ciprofloxacin based on initial clinical and radiologic impression. bone scans were obtained at diagnosis and 1 year later. IN 31 patients, increased focal activity was shown on the delayed images. Nineteen of 25 were successfully treated with 3 months of antibiotics, but only one of six were successfully treated with 3 weeks of antibiotics. Eight patient showed no focal increased uptake on delayed images, and seven of these were successfully treated with 3 weeks of antibiotics

  15. A novel method to augment extraction of mangiferin by application of microwave on three phase partitioning.

    Science.gov (United States)

    Kulkarni, Vrushali M; Rathod, Virendra K

    2015-06-01

    This work reports a novel approach where three phase partitioning (TPP) was combined with microwave for extraction of mangiferin from leaves of Mangifera indica . Soxhlet extraction was used as reference method, which yielded 57 mg/g in 5 h. Under optimal conditions such as microwave irradiation time 5 min, ammonium sulphate concentration 40% w/v, power 272 W, solute to solvent ratio 1:20, slurry to t -butanol ratio 1:1, soaking time 5 min and duty cycle 50%, the mangiferin yield obtained was 54 mg/g by microwave assisted three phase partitioning extraction (MTPP). Thus extraction method developed resulted into higher extraction yield in a shorter span, thereby making it an interesting alternative prior to down-stream processing.

  16. A novel method to augment extraction of mangiferin by application of microwave on three phase partitioning

    Directory of Open Access Journals (Sweden)

    Vrushali M. Kulkarni

    2015-06-01

    Full Text Available This work reports a novel approach where three phase partitioning (TPP was combined with microwave for extraction of mangiferin from leaves of Mangifera indica. Soxhlet extraction was used as reference method, which yielded 57 mg/g in 5 h. Under optimal conditions such as microwave irradiation time 5 min, ammonium sulphate concentration 40% w/v, power 272 W, solute to solvent ratio 1:20, slurry to t-butanol ratio 1:1, soaking time 5 min and duty cycle 50%, the mangiferin yield obtained was 54 mg/g by microwave assisted three phase partitioning extraction (MTPP. Thus extraction method developed resulted into higher extraction yield in a shorter span, thereby making it an interesting alternative prior to down-stream processing.

  17. Three Phase Power Imbalance Decomposition into Systematic Imbalance and Random Imbalance

    DEFF Research Database (Denmark)

    Kong, Wangwei; Ma, Kang; Wu, Qiuwei

    2017-01-01

    Uneven load allocations and random load behaviors are two major causes for three-phase power imbalance. The former mainly cause systematic imbalance, which can be addressed by low-cost phase swapping; the latter contribute to random imbalance, which requires relatively costly demand...... minimum phase, or both. Then, this paper proposes a new method to decompose three-phase power series into a systematic imbalance component and a random imbalance component as the closed-form solutions of quadratic optimization models that minimize random imbalance. A degree of power imbalance...... is calculated based on the systematic imbalance component to guide phase swapping. Case studies demonstrate that 72.8% of 782 low voltage substations have systematic imbalance components. The degree of power imbalance results reveal the maximum need for phase swapping and the random imbalance components reveal...

  18. An animal experimental study of transient synovitis of hip using three phase bone imaging

    International Nuclear Information System (INIS)

    Liang Jiugen; Lu Bing; Lu Xiaohu; Liu Shangli

    1994-01-01

    A model of transient synovitis was established by means of injecting noradrenaline (NA) into the joint cavity of young dogs. Radionuclide three phase bone imaging was then used to observe the local blood supply of femoral head and histological examination was used to understand the natural course of the disease process. The result showed that there were transient synovitis of the hip and decrease of blood supply in the affected femoral head after NA injection, but the changes gradually returned to normal after 4 weeks. No evidence of femoral head necrosis had been noticed. It is suggested that serial quantitative analysis of three phase bone imaging may have good clinical value in the early diagnosis transient hip synovitis, as well as in the assessment of the stage of the disease etc

  19. Dynamic\tmodelling of catalytic three-phase reactors for hydrogenation and oxidation processes

    Directory of Open Access Journals (Sweden)

    Salmi T.

    2000-01-01

    Full Text Available The dynamic modelling principles for typical catalytic three-phase reactors, batch autoclaves and fixed (trickle beds were described. The models consist of balance equations for the catalyst particles as well as for the bulk phases of gas and liquid. Rate equations, transport models and mass balances were coupled to generalized heterogeneous models which were solved with respect to time and space with algorithms suitable for stiff differential equations. The aspects of numerical solution strategies were discussed and the procedure was illustrated with three case studies: hydrogenation of aromatics, hydrogenation of aldehydes and oxidation of ferrosulphate. The case studies revealed the importance of mass transfer resistance inside the catalyst pallets as well as the dynamics of the different phases being present in the reactor. Reliable three-phase reactor simulation and scale-up should be based on dynamic heterogeneous models.

  20. Analysis of Three-Phase Rectifier Systems with Controlled DC-Link Current Under Unbalanced Grids

    DEFF Research Database (Denmark)

    Kumar, Dinesh; Davari, Pooya; Zare, Firuz

    2017-01-01

    Voltage unbalance is the most common disturbance in distribution networks, which give undesirable effects on many grid connected power electronics systems including Adjustable Speed Drive (ASD). Severe voltage unbalance can force three-phase rectifiers into almost single-phase operation, which...... degrades the grid power quality and also imposes a significant negative impact on the ASD system. This major power quality issue affecting the conventional rectifiers can be attenuated by controlling the DC-link current based on an Electronic Inductor (EI) technique. The purpose of this digest...... is to analyze and compare the performance of an EI with a conventional three-phase rectifier under unbalanced grid conditions. Experimental and simulation results validate the proposed mathematical modelling. Further analysis and benchmarking will be provided in the final paper....

  1. A modified two-level three-phase quasi-soft-switching inverter

    DEFF Research Database (Denmark)

    Liu, Yusheng; Wu, Weimin; Blaabjerg, Frede

    2014-01-01

    A traditional Voltage Source Inverter (VSI) has higher efficiency than a Current Voltage Source (CSI) due to the less conduction power loss. However, the reverse recovery of the free-wheeling diode limits the efficiency improvement for the silicon devices based hard-switching VSI. The traditional...... quasi-soft-switching inverter can alternate between VSI and CSI by using a proper control scheme and thereby reduce the power losses caused by the reverse recovery of the free-wheeling diode. Nevertheless, slightly extra conduction power loss of the auxiliary switch is also introduced. In order...... to reduce the extra conduction power loss and the voltage stress across the DC-link capacitor, a modified two-level three-phase quasi-soft-switching inverter is proposed by using a SiC MOSFET instead of an IGBT. The principle of the modified two-level three-phase quasi-soft-switching inverter is analyzed...

  2. Improved control strategy for the three-phase grid-connected inverter

    DEFF Research Database (Denmark)

    Yao, Zhilei; Xiao, Lan; Guerrero, Josep M.

    2015-01-01

    An improved control strategy for the three-phase grid-connected inverter with space vector pulse width modulation (SVPWM) is proposed. When the grid current contains harmonics, the d- and q-axis grid currents will be interacted, and then the waveform quality of the grid current will be poorer....... As the reference output voltage cannot directly reflect the change of the reference grid current, the dynamic response of the grid-connected inverter is slow. In order to solve the aforementioned problems, the d- and q-axis grid currents in the decoupled components of the grid current controller can be substituted...... by the d- and q-axis reference grid currents, respectively. The operating principles of the traditional and proposed control methods are illustrated. Experimental results for a 15-kVA three-phase grid-connected inverter with SVPWM verify the theoretical analysis. Compared with the traditional control...

  3. Analysis of three-phase power-supply systems using computer-aided design programs

    International Nuclear Information System (INIS)

    Oberst, E.F.

    1977-01-01

    A major concern of every designer of large, three-phase power-supply systems is the protection of system components from overvoltage transients. At present, three computer-aided circuit design programs are available in the Magnetic Fusion Energy (MFE) National Computer Center that can be used to analyze three-phase power systems: MINI SCEPTRE, SPICE I, and SPICE II. These programs have been used at Lawrence Livermore Laboratory (LLL) to analyze the operation of a 200-kV dc, 20-A acceleration power supply for the High Voltage Test Stand. Various overvoltage conditions are simulated and the effectiveness of system protective devices is observed. The simulated overvoltage conditions include such things as circuit breaker openings, pulsed loading, and commutation voltage surges in the rectifiers. These examples are used to illustrate the use of the computer-aided, circuit-design programs discussed in this paper

  4. A TECHNIQUE OF IDENTIFICATION OF THE PHASE-DISPLACEMENT GROUP OF THREE-PHASE TRANSFORMER

    International Nuclear Information System (INIS)

    Aburjania, A.; Begiashvili, V.; Rezan Turan

    2007-01-01

    It is demonstrated that the arbitrary choice of arbitrarily pisitive direction of induced currents and voltages contradicts the energy conservation law and leads to equilibrium equations and standards making no sense from the physical standpoint. Of 12 recognized standard phase-displacement groups of three-phase transformer, only three have real physical bases. The rest are based on a wrong assumption about mutual biasing of primary and secondary currents. They does not rule out the occurrence of emergency situations and, thus, must be eliminated from use. A new method of identification of the phase-displacement of three-phase transformer is proposed. The method is based on well-known physical laws with consideration for the dual character of the inertia of mutual inductance and exhausts for all possible versions of connection of transformer windings. (author)

  5. Voltage unbalance mitigation in LV networks using three-phase PV systems

    DEFF Research Database (Denmark)

    Garcia Bajo, Cristina; Hashemi Toghroljerdi, Seyedmostafa; Bækhøj Kjær, Søren

    2015-01-01

    In this paper a new method is proposed to mitigate voltage unbalance caused by single-phase solar inverters in low voltage (LV) networks. The method is based on uneven reactive power absorption and injection by three-phase solar inverters. Independent control of each phase is performed to achieve...... this uneven injection. The average values of phase voltages at the connection points of the photovoltaic (PV) inverters are used as the references for the balancing algorithm. Voltage unbalance mitigation is achieved by use of this method in different scenarios with variable three-phase and single......-phase inverters penetration in a realistic LV grid. In addition, the overvoltage is reduced by using this method....

  6. Proportional-Resonant Controllers. A New Breed of Controllers Suitable for Grid-Connected Voltage-Source Converters

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede

    2004-01-01

    This paper is describing the recently introduced proportional-resonant (PR) controllers and their suitability for grid-connected converters current control. It is shown that the known shortcomings associated with PI controllers like steady - state error for single-phase converters and the need...... of decoupling for three-phase converters can be alleviated. Additionally, selective harmonic compensation is also possible with PR controllers. Suggested control-diagrams for three-phase grid converters and active filters are also presented. A practical application of PR current control for a photovoltaic (PV...

  7. Voltage harmonic variation in three-phase induction motors with different coil pitches

    International Nuclear Information System (INIS)

    Deshmukh, Ram; Moses, Anthony John; Anayi, Fatih

    2006-01-01

    A pulse-width modulation (PWM) inverter feeding four different chorded three-phase induction motors was tested for low-order odd harmonic voltage component and efficiency at different loads. Total harmonic distortion (THD) due to 3rd, 5th and 9th harmonics was less in a motor with 160 o coil pitch. Particular harmonic order for each coil pitch was suppressed and the efficiency of a 120 o coil pitch motor was increased by 7.5%

  8. A variable frequency three phase inverter for use with Philips cryogenerators

    International Nuclear Information System (INIS)

    Carter, R.C.

    1977-10-01

    This report describes a solid state inverter designed to power the helium circulators on the cryogenerators used on the Rapid Cycling Vertex Detector at the Rutherford Laboratory. In these cryogenerators cold helium is pumped around the refrigeration loop by a small three phase induction motor. The motor requires a supply of 220 volts, 40 mA per phase, and varying in frequency between 200 and 300 Hz, depending on the length and general characteristics of the loop and transfer line. (author)

  9. Controlling a Four-Quadrant Brushless Three-Phase dc Motor

    Science.gov (United States)

    Nola, F. J.

    1986-01-01

    Control circuit commutates windings of brushless, three-phase, permanent-magnet motor operating from power supply. With single analog command voltage, controller makes motor accelerate, drive steadily, or brake regeneratively, in clockwise or counterclockwise direction. Controller well suited for use with energy-storage flywheels, actuators for aircraft-control surfaces, cranes, industrial robots, and other electromechanical systems requiring bidirectional control or sudden stopping and reversal.

  10. Three-phase boundary length in solid-oxide fuel cells: A mathematical model

    Energy Technology Data Exchange (ETDEWEB)

    Janardhanan, Vinod M. [Institutefor Chemical Technology and Polymer Chemistry, University of Karlsruhe (TH), Kaiserstr. 12, D-76128 Karlsruhe (Germany); Heuveline, Vincent; Deutschmann, Olaf [Institute for Applied and Numerical Mathematics, University of Karlsruhe (TH), Kaiserstr. 12, D-76128 Karlsruhe (Germany)

    2008-03-15

    A mathematical model to calculate the volume specific three-phase boundary length in the porous composite electrodes of solid-oxide fuel cell is presented. The model is exclusively based on geometrical considerations accounting for porosity, particle diameter, particle size distribution, and solids phase distribution. Results are presented for uniform particle size distribution as well as for non-uniform particle size distribution. (author)

  11. Investigation on Capacitor Switching Transient Limiter with a Three phase Variable Resistance

    DEFF Research Database (Denmark)

    Naderi, Seyed Behzad; Jafari, Mehdi; Zandnia, Amir

    2017-01-01

    In this paper, a capacitor switching transient limiter based on a three phase variable resistance is proposed. The proposed structure eliminates the capacitor switching transient current and over-voltage by introducing a variable resistance to the current path with its special switching pattern...... transients on capacitor after bypassing. Analytic Analyses for this structure in transient cases are presented in details and simulations are performed by MATLAB software to prove its effectiveness....

  12. Design of materials with extreme thermal expansion using a three-phase topology optimization method

    DEFF Research Database (Denmark)

    Sigmund, Ole; Torquato, S.

    1997-01-01

    Composites with extremal or unusual thermal expansion coefficients are designed using a three-phase topology optimization method. The composites are made of two different material phases and a void phase. The topology optimization method consists in finding the distribution of material phases...... materials having maximum directional thermal expansion (thermal actuators), zero isotropic thermal expansion, and negative isotropic thermal expansion. It is shown that materials with effective negative thermal expansion coefficients can be obtained by mixing two phases with positive thermal expansion...

  13. Physics of automated driving in framework of three-phase traffic theory.

    Science.gov (United States)

    Kerner, Boris S

    2018-04-01

    We have revealed physical features of automated driving in the framework of the three-phase traffic theory for which there is no fixed time headway to the preceding vehicle. A comparison with the classical model approach to automated driving for which an automated driving vehicle tries to reach a fixed (desired or "optimal") time headway to the preceding vehicle has been made. It turns out that automated driving in the framework of the three-phase traffic theory can exhibit the following advantages in comparison with the classical model of automated driving: (i) The absence of string instability. (ii) Considerably smaller speed disturbances at road bottlenecks. (iii) Automated driving vehicles based on the three-phase theory can decrease the probability of traffic breakdown at the bottleneck in mixed traffic flow consisting of human driving and automated driving vehicles; on the contrary, even a single automated driving vehicle based on the classical approach can provoke traffic breakdown at the bottleneck in mixed traffic flow.

  14. Research on three-phase traffic flow modeling based on interaction range

    Science.gov (United States)

    Zeng, Jun-Wei; Yang, Xu-Gang; Qian, Yong-Sheng; Wei, Xu-Ting

    2017-12-01

    On the basis of the multiple velocity difference effect (MVDE) model and under short-range interaction, a new three-phase traffic flow model (S-MVDE) is proposed through careful consideration of the influence of the relationship between the speeds of the two adjacent cars on the running state of the rear car. The random slowing rule in the MVDE model is modified in order to emphasize the influence of vehicle interaction between two vehicles on the probability of vehicles’ deceleration. A single-lane model which without bottleneck structure under periodic boundary conditions is simulated, and it is proved that the traffic flow simulated by S-MVDE model will generate the synchronous flow of three-phase traffic theory. Under the open boundary, the model is expanded by adding an on-ramp, the congestion pattern caused by the bottleneck is simulated at different main road flow rates and on-ramp flow rates, which is compared with the traffic congestion pattern observed by Kerner et al. and it is found that the results are consistent with the congestion characteristics in the three-phase traffic flow theory.

  15. A three-phase comprehensive mathematical model of desulfurization in electroslag remelting process

    International Nuclear Information System (INIS)

    Wang, Qiang; Li, Guangqiang; He, Zhu; Li, Baokuan

    2017-01-01

    Highlights: • First developed a three-phase coupled model of desulfurization in ESR process. • The MHD thermal flow in the reactor was clarified. • Distributions of sulfur concentration in the three phases were demonstrated. • An experiment was carried out to validate the simulation. - Abstract: A three-phase comprehensive mathematical model has been established to study the desulfurization behavior in electroslag remelting (ESR) process. The solutions of the mass, momentum, energy, and species conservation equations were simultaneously calculated by the finite volume method. The Joule heating and Lorentz force were fully coupled through solving the Maxwell’s equations with the assistance of the magnetic potential vector. The movements of the air-slag and slag-metal interfaces were described by the volume of fluid (VOF) approach. In order to include the influences of the air, the slag and the electric current on the desulfurization, a thermodynamic and kinetic module was introduced. An experiment was conducted to validate the model. The completely comparison between the measured and simulated data indicates that the model can describe the desulfurization behavior in the ESR process with an acceptable accuracy. The sulfur in the metal would be transferred into the slag under the combined effect of the slag treatment and the electrochemical reaction, and is primarily achieved in the period of the droplet formation. The sulfur in the slag then could be transferred into the air because of the oxidation. The maximum calculated removal ratio in the whole process is around 88%.

  16. Physics of automated driving in framework of three-phase traffic theory

    Science.gov (United States)

    Kerner, Boris S.

    2018-04-01

    We have revealed physical features of automated driving in the framework of the three-phase traffic theory for which there is no fixed time headway to the preceding vehicle. A comparison with the classical model approach to automated driving for which an automated driving vehicle tries to reach a fixed (desired or "optimal") time headway to the preceding vehicle has been made. It turns out that automated driving in the framework of the three-phase traffic theory can exhibit the following advantages in comparison with the classical model of automated driving: (i) The absence of string instability. (ii) Considerably smaller speed disturbances at road bottlenecks. (iii) Automated driving vehicles based on the three-phase theory can decrease the probability of traffic breakdown at the bottleneck in mixed traffic flow consisting of human driving and automated driving vehicles; on the contrary, even a single automated driving vehicle based on the classical approach can provoke traffic breakdown at the bottleneck in mixed traffic flow.

  17. A Three-Phase Multiobjective Mechanism for Selecting Retail Stores to Close

    Directory of Open Access Journals (Sweden)

    Rong-Chang Chen

    2016-01-01

    Full Text Available To operate a successful and growing business, a retail store manager has to make tough decisions about selectively closing underperforming stores. In this paper, we propose using a three-phase multiobjective mechanism to help retail industry practitioners determine which stores to close. In the first phase, a geographic information system (GIS and k-means clustering algorithm are used to divide all the stores into clusters. In the second phase, stores can be strategically selected according to the requirements of the company and the attributes of the stores. In the third phase, a neighborhood-based multiobjective genetic algorithm (NBMOGA is utilized to determine which stores to close. To examine the effectiveness of the proposed three-phase mechanism, a variety of experiments are performed, based partly on a real dataset from a stock-list company in Taiwan. Results from the experiments show that the proposed three-phase mechanism can help efficiently decide which store locations to close. In addition, the neighborhood radius has a considerable influence on the results.

  18. Ac-dc converter firing error detection

    International Nuclear Information System (INIS)

    Gould, O.L.

    1996-01-01

    Each of the twelve Booster Main Magnet Power Supply modules consist of two three-phase, full-wave rectifier bridges in series to provide a 560 VDC maximum output. The harmonic contents of the twelve-pulse ac-dc converter output are multiples of the 60 Hz ac power input, with a predominant 720 Hz signal greater than 14 dB in magnitude above the closest harmonic components at maximum output. The 720 Hz harmonic is typically greater than 20 dB below the 500 VDC output signal under normal operation. Extracting specific harmonics from the rectifier output signal of a 6, 12, or 24 pulse ac-dc converter allows the detection of SCR firing angle errors or complete misfires. A bandpass filter provides the input signal to a frequency-to-voltage converter. Comparing the output of the frequency-to-voltage converter to a reference voltage level provides an indication of the magnitude of the harmonics in the ac-dc converter output signal

  19. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... analyzed with loads connected to △. But it will be further researched in the future. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping three-level inverter is briefly presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS...... is very powerful tool to real power circuits and it is very easy to simulate them. They have also verified that SVM control strategy is feasible to control the diode clamping three-level inverter....

  20. Optimization Control of Bidirectional Cascaded DC-AC Converter Systems

    DEFF Research Database (Denmark)

    Tian, Yanjun

    in bidirectional cascaded converter. This research work analyses the control strategies based on the topology of dual active bridges converter cascaded with a three phase inverter. It firstly proposed a dc link voltage and active power coordinative control method for this cascaded topology, and it can reduce dc....... The connections of the renewable energy sources to the power system are mostly through the power electronic converters. Moreover, for high controllability and flexibility, power electronic devices are gradually acting as the interface between different networks in power systems, promoting conventional power...... the bidirectional power flow in the distribution level of power systems. Therefore direct contact of converters introduces significant uncertainties to power system, especially for the stability and reliability. This dissertation studies the optimization control of the two stages directly connected converters...

  1. A new model predictive control algorithm by reducing the computing time of cost function minimization for NPC inverter in three-phase power grids.

    Science.gov (United States)

    Taheri, Asghar; Zhalebaghi, Mohammad Hadi

    2017-11-01

    This paper presents a new control strategy based on finite-control-set model-predictive control (FCS-MPC) for Neutral-point-clamped (NPC) three-level converters. Containing some advantages like fast dynamic response, easy inclusion of constraints and simple control loop, makes the FCS-MPC method attractive to use as a switching strategy for converters. However, the large amount of required calculations is a problem in the widespread of this method. In this way, to resolve this problem this paper presents a modified method that effectively reduces the computation load compare with conventional FCS-MPC method and at the same time does not affect on control performance. The proposed method can be used for exchanging power between electrical grid and DC resources by providing active and reactive power compensations. Experiments on three-level converter for three Power Factor Correction (PFC), inductive and capacitive compensation modes verify the good and comparable performance. The results have been simulated using MATLAB/SIMULINK software. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Technologies for converter topologies

    Science.gov (United States)

    Zhou, Yan; Zhang, Haiyu

    2017-02-28

    In some embodiments of the disclosed inverter topologies, an inverter may include a full bridge LLC resonant converter, a first boost converter, and a second boost converter. In such embodiments, the first and second boost converters operate in an interleaved manner. In other disclosed embodiments, the inverter may include a half-bridge inverter circuit, a resonant circuit, a capacitor divider circuit, and a transformer.

  3. Wavelength converter technology

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Poulsen, Henrik Nørskov

    1999-01-01

    Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers.......Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers....

  4. Schemes for Probabilistic Teleportation of an Unknown Three-Particle Three-Level Entangled State

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In this paper, two schemes for teleporting an unknown three-particle three-level entangled state are proposed. In the first scheme, two partial three-particle three-level entangled states are used as the quantum channels, while in the second scheme, three two-particle three-level non-maximally entangled states are employed as quantum channels.It is shown that the teleportation can be successfully realized with certain probability, for both two schemes, if a receiver adopts some appropriate unitary transformations. It is shown also that the successful probabilities of these two schemes are different.

  5. ESTABLISHED MODES AND STATIC CHARACTERISTICS OF THREE-PHASE ASYNCHRONOUS MOTOR POWERED WITH SINGLE PHASE NETWORK

    Directory of Open Access Journals (Sweden)

    V. S. Malyar

    2016-01-01

    Full Text Available A mathematical model is developed to study the operation of three-phase asynchronous motor with squirrel-cage rotor when the stator winding is powered from a single phase network. To create a rotating magnetic field one of the phases is fed through the capacitor. Due to the asymmetry of power feed not only transients, but the steady-state regimes are dynamic, so they are described by differential equations in any coordinate system. Their study cannot be carried out with sufficient adequacy on the basis of known equivalent circuits and require the use of dynamic parameters. In the mathematical model the state equations of the circuits of the stator and rotor are composed in the stationary three phase coordinate system. Calculation of the established mode is performed by solving the boundary problem that makes it possible to obtain the coordinate dependences over the period, without calculation of the transient process. In order to perform it, the original nonlinear differential equations are algebraized by approximating the variables with the use of cubic splines. The resulting nonlinear system of algebraic equations is a discrete analogue of the initial system of differential equations. It is solved by parameter continuation method. To calculate the static characteristics as a function of a certain variable, the system is analytically differentiated, and then numerically integrated over this variable. In the process of integration, Newton's refinement is performed at each step or at every few steps, making it possible to implement the integration in just a few steps using Euler's method. Jacobi matrices in both cases are the same. To account for the current displacement in the rods of the squirrel-cage rotor, each of them, along with the squirrel-cage rings, is divided in height into several elements. This results in several squirrel-cage rotor windings which are represented by three-phase windings with magnetic coupling between them.

  6. Three-phase metal kinetics in terrestrial invertebrates exposed to high metal concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Laskowski, Ryszard, E-mail: ryszard.laskowski@uj.edu.pl [Institute of Environmental Sciences, Jagiellonian University, Gronostajowa 7, 30-387 Krakow (Poland); Bednarska, Agnieszka J. [Institute of Environmental Sciences, Jagiellonian University, Gronostajowa 7, 30-387 Krakow (Poland); Spurgeon, David; Svendsen, Claus [Centre for Ecology and Hydrology, Maclean Building, Benson Lane, Crowmarsh Gifford, Wallingford, Oxon, OX10 8BB (United Kingdom); Gestel, Cornelis A.M. van [Institute of Ecological Science, Vrije Universiteit, De Boelelaan 1085, 1081 HV Amsterdam (Netherlands)

    2010-08-15

    Models of metal toxicokinetics are critically evaluated using both newly generated data in the NoMiracle project as well as those originating from older studies. The analysis showed that the most frequently used one-compartment two-phase toxicokinetic model, with one assimilation and one elimination rate constant, does not describe correctly certain data sets pertaining particularly to the pattern of assimilation of trace elements. Using nickel toxicokinetics in carabid beetles and earthworms as examples, we showed that Ni in fact exhibits a three-phase kinetics with a short phase of fast metal accumulation immediately after exposure, followed by partial elimination to an equilibrium concentration at a later stage of a metal exposure phase, and by final elimination upon transfer to an uncontaminated food/soil. A similar phenomenon was also found for data on cadmium kinetics in ground beetles and copper kinetics in earthworms in data already published in the literature that was not accounted for in the earlier analysis of the data. The three-phase model suggests that the physiology of controlling body metal concentrations can change shortly after exposure, at least in some cases, by increasing the elimination rate and/or decreasing metal assimilation. Hence, the three-phase model, that allows for different assimilation and/or elimination rates in different phases of exposure to a toxicant, may provide insight into temporal changes in the physiology of metal handling. Consequently, this alternative model should always be tested when describing metal toxicokinetics when temporal patterns of internal metal concentration exhibit an initial 'overshoot' in body metal concentrations.

  7. Three-phase metal kinetics in terrestrial invertebrates exposed to high metal concentrations

    International Nuclear Information System (INIS)

    Laskowski, Ryszard; Bednarska, Agnieszka J.; Spurgeon, David; Svendsen, Claus; Gestel, Cornelis A.M. van

    2010-01-01

    Models of metal toxicokinetics are critically evaluated using both newly generated data in the NoMiracle project as well as those originating from older studies. The analysis showed that the most frequently used one-compartment two-phase toxicokinetic model, with one assimilation and one elimination rate constant, does not describe correctly certain data sets pertaining particularly to the pattern of assimilation of trace elements. Using nickel toxicokinetics in carabid beetles and earthworms as examples, we showed that Ni in fact exhibits a three-phase kinetics with a short phase of fast metal accumulation immediately after exposure, followed by partial elimination to an equilibrium concentration at a later stage of a metal exposure phase, and by final elimination upon transfer to an uncontaminated food/soil. A similar phenomenon was also found for data on cadmium kinetics in ground beetles and copper kinetics in earthworms in data already published in the literature that was not accounted for in the earlier analysis of the data. The three-phase model suggests that the physiology of controlling body metal concentrations can change shortly after exposure, at least in some cases, by increasing the elimination rate and/or decreasing metal assimilation. Hence, the three-phase model, that allows for different assimilation and/or elimination rates in different phases of exposure to a toxicant, may provide insight into temporal changes in the physiology of metal handling. Consequently, this alternative model should always be tested when describing metal toxicokinetics when temporal patterns of internal metal concentration exhibit an initial 'overshoot' in body metal concentrations.

  8. Study and Experiment on Non-Contact Voltage Sensor Suitable for Three-Phase Transmission Line.

    Science.gov (United States)

    Zhou, Qiang; He, Wei; Xiao, Dongping; Li, Songnong; Zhou, Kongjun

    2015-12-30

    A voltage transformer, as voltage signal detection equipment, plays an important role in a power system. Presently, more and more electric power systems are adopting potential transformer and capacitance voltage transformers. Transformers are often large in volume and heavyweight, their insulation design is difficult, and an iron core or multi-grade capacitance voltage division structure is generally adopted. As a result, the detection accuracy of transformer is reduced, a huge phase difference exists between detection signal and voltage signal to be measured, and the detection signal cannot accurately and timely reflect the change of conductor voltage signal to be measured. By aiming at the current problems of electric transformation, based on electrostatic induction principle, this paper designed a non-contact voltage sensor and gained detection signal of the sensor through electrostatic coupling for the electric field generated by electric charges of the conductor to be measured. The insulation structure design of the sensor is simple and its volume is small; phase difference of sensor measurement is effectively reduced through optimization design of the electrode; and voltage division ratio and measurement accuracy are increased. The voltage sensor was tested on the experimental platform of simulating three-phase transmission line. According to the result, the designed non-contact voltage sensor can realize accurate and real-time measurement for the conductor voltage. It can be applied to online monitoring for the voltage of three-phase transmission line or three-phase distribution network line, which is in accordance with the development direction of the smart grid.

  9. Three phase dynamic CT with double spiral CT: utility of determination of stomach cancer stage

    International Nuclear Information System (INIS)

    Jung, Min Ha; Kim, Hong In; Kim, Tae Hyung; Lee, Ki Yeol; Cho, June Il; Park, Cheol Min; Cha, In Ho

    1997-01-01

    To evaluate the utility of three phases of spiral CT in the diagnosis of stomach cancer. Between August 1994 and March 1995, thirty eight patients with stomach cancer, demonstrated on spiral CT, underwent surgery. Twenty-eight cases were advanced and ten were early. There were 27 men, and 11 women, and their average age was 52.8 years old (33-77). After ingestion of 600-700ml of water, 120-140ml of nonionic contrast material was injected intravenously. Spiral CT scanning was performed in 10mm slice thickness and of 10mm/sec table speed. Three phase image were obtained at 25sec (arterial phase), 60-65sec (venous phase) and 4min (equilibrium phase) after the start of bolus injection. On each phase, CT findings were compared with pathologic results, and tumor detectibility, depth of tumor invasion and lymph node metastasis was analysed. Thirty of the 38 carcinomas (79%) were detected on the arterial phase, 33 (81%) on the venous phase and 30 (79%) on the equilibrium phase. Depth of tumor invasion was measured accurately in 27 of 38 cases (71%) : T1-4/10 (40%), T2-8/11 (73%), T3-13/15 (87%), T4-2/2 (100%). We overstaged one case of T1 as T2 and two cases of T2 as T3, and understaged one case of T2 as T1 and two cases of T3 as T2. Among the 16 enlarged lymph nodes larger than 8mm, 13 cases were positive on pathologic examination and the sensitivity was 65%. With three-phase spiral CT scanning, we obtained 71% accuracy of depth of tumor invasion. The venous phase is most useful for tumor detection and for determining depth of tumor invasion and lymph node metastasis

  10. A three-phase microfluidic chip for rapid sample clean-up of alkaloids from plant extracts

    NARCIS (Netherlands)

    Tetala, K.K.R.; Swarts, J.W.; Chen, B.; Janssen, A.E.M.; Beek, van T.A.

    2009-01-01

    A three-phase microchip was developed for the rapid and efficient small-scale purification of alkaloids from plant extracts. As part of the development of such a three-phase microchip, first a two-phase microchip with two channels (3.2 cm and 9.3 cm) was used to study the extraction efficiency of

  11. Dead Zone Oscillator Control for Communication-Free Synchronization of Paralleled, Three-Phase, Current-Controlled Inverters

    Science.gov (United States)

    2016-05-11

    Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab, USN UNITED STATES NAVAL ACADEMY...Three-Phase, Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab United States Naval Academy Annapolis, Maryland...for Communication-Free Synchronization of Paralleled, 5a. CONTRACT NUMBER Three-Phase, Current-Controlled Inverters 5b. GRANT NUMBER 5c

  12. Optimized Carrier Based Multilevel Generated Modified Dual Three-Phase Open-Winding Inverter for Medium Power Applications

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Wheeler, Patrick

    2016-01-01

    This paper presents a novel carrier based multilevel modulation for modified dual three-phase open-winding inverter applicable for low-voltage/high-current applications. A standard three-phase voltage source inverter (VSI) is connected across the open-winding of both ends of the motor. Each VSI i...

  13. Skull base osteomyelitis: role of three phase and hybrid SPECT/CT bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, D.; Bhattacharaya, A.; Kamaleshwaran, K.K.; Mittal, B.R.; Aggarwal, K.; Singh, B.; Bhoil, A.

    2010-01-01

    Full text: Skull base osteomyelitis is the infection that has spread to the skull base, beyond the external auditory canal and seen in advanced stage of malignant otitis externa. Early diagnosis of this condition includes the use of bone scintigraphy since clinical assessment alone cannot differentiate the skull base osteomyelitis from the severe type of otitis externa in which there is no extension to the adjacent bone. Objective: To determine the role of three phase bone scintigraphy and delayed SPECT/CT in detection of skull base osteomyelitis in patients with malignant otitis externa. Material and Methods: Clinical records of 20 patients (14 Males and 6 Females; mean age 72 yrs) of otitis externa with suspected skull base involvement referred for bone scintigraphies were analyzed retrospectively. Three phase bone scintigraphy was acquired under dual detector gamma camera after intravenous injection of 20 mCi (740 MBq) 99m Tc-MDP followed by SPECT/CT of the skull. Scintigraphic findings were compared with clinical symptoms, signs and diagnostic CT scan findings. Results: All the patients except one were diabetic and having elevated ESR. 18 patients presented with bilateral symptoms and rest unilateral. Cranial nerves were involved in 8 patients (40%). Ear discharge culture sensitivity report was found in three patients; it was positive for Pseudomonas aeruginosa for two patients and in Diptheroids for one. In 9 patients (45%) increased flow of tracer and 10 patients (50%) increased blood pool phase in the temporal region was found. Delayed phase images showed increased uptake in skull bone in 19 patients (95%). Hybrid SPECT/CT of the skull localized areas of increased tracer uptake to the mastoid part in 15 patients (75%), petrous part in 11 patients (55%), sphenoid in 3 patients (15%) and zygomatic bone in one patient (5%) with CT showing destructive changes in 5 patients (25%) which were corroborated with diagnostic CT findings. SPECT/CT along with three phase

  14. Vector control of three-phase AC machines system development in the practice

    CERN Document Server

    Quang, Nguyen Phung; Dittrich, J

    2015-01-01

    This book addresses the vector control of three-phase AC machines, in particular induction motors with squirrel-cage rotors (IM), permanent magnet synchronous motors (PMSM) and doubly-fed induction machines (DFIM), from a practical design and development perspective. The main focus is on the application of IM and PMSM in electrical drive systems, where field-orientated control has been successfully established in practice. It also discusses the use of grid-voltage oriented control of DFIMs in wind power plants. This second, enlarged edition includes new insights into flatness-based  nonlinear

  15. Wavelet-Fuzzy Speed Indirect Field Oriented Controller for Three-Phase AC Motor Drive

    DEFF Research Database (Denmark)

    Sanjeevikumar, Padmanaban; Daya, Febin; Blaabjerg, Frede

    2016-01-01

    Three-phase voltage source inverter driven induction motor are used in many medium- and high-power applications. Precision in speed of the motor play vital role, i.e. popular methods of direct/indirect field-oriented control (FOC) are applied. FOC is employed with proportional-integral (P...... wavelet transform and the fuzzy logic controller, to generate the scaled gains for the indirect FOC induction motor. Complete model of the proposed ac motor drive is developed with numerical simulation Matlab/Simulink software and tested under different working conditions. For experimental verification...

  16. A parametric study on unbalanced three phase islanded microgrids with inverter interfaced units

    DEFF Research Database (Denmark)

    Sanseverino, Eleonora Riva; Quang, Ninh Nguyen; Zizzo, Gaetano

    2013-01-01

    In this paper, the solution of the power flow for unbalanced three phase microgrids systems is proposed. The study aims at the integration of inverter interfaced units using the control law used for primary voltage and frequency regulation, so as to take into account possible small variations...... of these parameters to account for sudden load changes. The proposed study deals with unbalanced systems which is the typical case of small distribution systems and shows how the power losses term varies as the regulators parameters vary as well, thus showing that these are sensitive parameters that could have...

  17. Distributed Strategy for Optimal Dispatch of Unbalanced Three-Phase Islanded Microgrids

    DEFF Research Database (Denmark)

    Vergara Barrios, Pedro Pablo; Rey-López, Juan Manuel; Shaker, Hamid Reza

    2018-01-01

    This paper presents a distributed strategy for the optimal dispatch of islanded microgrids, modeled as unbalanced three-phase electrical distribution systems (EDS). To set the dispatch of the distributed generation (DG) units, an optimal generation problem is stated and solved distributively based......-phase microgrid. According to the obtained results, the proposed strategy achieves a lower cost solution when compared with a centralized approach based on a static droop framework, with a considerable reduction on the communication system complexity. Additionally, it corrects the mismatch between generation...

  18. Secondary Voltage Unbalance Compensation for Three-Phase Four-Wire Islanded Microgrids

    DEFF Research Database (Denmark)

    Tang, Fen; Zhou, Xiao; Meng, Lexuan

    2014-01-01

    This paper proposes a secondary voltage unbalance control approach that compensate voltage unbalances in three-phase four-wire islanded microgrid systems. It is implemented in the secondary control level of the microgrid hierarchical control structure. By sending information through low......-bandwidth communication links to the primary control level, the required unbalanced factors at sensitive buses are achieved. Also, negative and zero sequence equivalent circuits and unbalance compensation principle are derived. Finally, real-time hardware-in-the-loop results show the feasibility of the proposed approach...

  19. High Efficiency Three-phase Power Factor Correction Rectifier using Wide Band-Gap Devices

    DEFF Research Database (Denmark)

    Kouchaki, Alireza

    Improving the conversion efficiency of power factor correction (PFC) rectifiers has become compelling due to their wide applications such as adjustable speed drives, uninterruptible power supplies (UPS), and battery chargers for electric vehicles (EVs). The attention to PFCs has increased even more....... Therefore, current controllers are also important to be investigated in this project. In this PhD research work, a comprehensive design of a two-level three-phase PFC rectifier using silicon-carbide (SiC) switches to achieve high efficiency is presented. The work is divided into two main parts: 1) Optimum...

  20. Text Previews and Three Level Study Guides for Content Area Critical Reading.

    Science.gov (United States)

    Bean, Thomas W.; Ericson, Bonnie O.

    1989-01-01

    Describes the integration of text previews (teacher-developed synopses of the text) and three-level study guides (encouraging factual, inferential, and problem solving responses). Claims a combination of these constitutes a powerful strategy for content area reading. (RS)

  1. Common voltage eliminating of SVM diode clamping three-level inverter connected to grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    A novel method of common voltage eliminating is put forward for SVM diode clamping three-level inverter connected to grid by calculation of common voltage of its various switching states. PLECS is used to model this three-level inverter connected to grid and good results are obtained. First...... analysis of common mode voltage for switching states of diode clamping 3-level inverter is given in detail. Second the common mode voltage eliminating control strategy of SVM is described for diode clamping three-level inverter. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping...... three-level inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is a very powerful tool to real power circuits modeling. They have also verified that proposed common mode voltage eliminating control strategy of SVM is feasible...

  2. Delta-Connected Cascaded H-Bridge Multilevel Converters for Large-Scale Photovoltaic Grid Integration

    DEFF Research Database (Denmark)

    Yu, Yifan; Konstantinou, Georgios; Townsend, Christopher D.

    2017-01-01

    The cascaded H-bridge (CHB) converter is becoming a promising candidate for use in next generation large-scale photovoltaic (PV) power plants. However, solar power generation in the three converter phase-legs can be significantly unbalanced, especially in a large geographically-dispersed plant....... The power imbalance between the three phases defines a limit for the injection of balanced three-phase currents to the grid. This paper quantifies the performance of, and experimentally confirms, the recently proposed delta-connected CHB converter for PV applications as an alternative configuration...... for large-scale PV power plants. The required voltage and current overrating for the converter is analytically developed and compared against the star-connected counterpart. It is shown that the delta-connected CHB converter extends the balancing capabilities of the star-connected CHB and can accommodate...

  3. Homogenization of linear viscoelastic three phase media: internal variable formulation versus full-field computation

    International Nuclear Information System (INIS)

    Blanc, V.; Barbie, L.; Masson, R.

    2011-01-01

    Homogenization of linear viscoelastic heterogeneous media is here extended from two phase inclusion-matrix media to three phase inclusion-matrix media. Each phase obeying to a compressible Maxwellian behaviour, this analytic method leads to an equivalent elastic homogenization problem in the Laplace-Carson space. For some particular microstructures, such as the Hashin composite sphere assemblage, an exact solution is obtained. The inversion of the Laplace-Carson transforms of the overall stress-strain behaviour gives in such cases an internal variable formulation. As expected, the number of these internal variables and their evolution laws are modified to take into account the third phase. Moreover, evolution laws of averaged stresses and strains per phase can still be derived for three phase media. Results of this model are compared to full fields computations of representative volume elements using finite element method, for various concentrations and sizes of inclusion. Relaxation and creep test cases are performed in order to compare predictions of the effective response. The internal variable formulation is shown to yield accurate prediction in both cases. (authors)

  4. Three-Phase AC Optimal Power Flow Based Distribution Locational Marginal Price: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui; Zhang, Yingchen

    2017-05-17

    Designing market mechanisms for electricity distribution systems has been a hot topic due to the increased presence of smart loads and distributed energy resources (DERs) in distribution systems. The distribution locational marginal pricing (DLMP) methodology is one of the real-time pricing methods to enable such market mechanisms and provide economic incentives to active market participants. Determining the DLMP is challenging due to high power losses, the voltage volatility, and the phase imbalance in distribution systems. Existing DC Optimal Power Flow (OPF) approaches are unable to model power losses and the reactive power, while single-phase AC OPF methods cannot capture the phase imbalance. To address these challenges, in this paper, a three-phase AC OPF based approach is developed to define and calculate DLMP accurately. The DLMP is modeled as the marginal cost to serve an incremental unit of demand at a specific phase at a certain bus, and is calculated using the Lagrange multipliers in the three-phase AC OPF formulation. Extensive case studies have been conducted to understand the impact of system losses and the phase imbalance on DLMPs as well as the potential benefits of flexible resources.

  5. Improved modeling of new three-phase high voltage transformer with magnetic shunts

    Directory of Open Access Journals (Sweden)

    Chraygane M.

    2015-03-01

    Full Text Available This original paper deals with a new approach for the study of behavior in nonlinear regime of a new three-phase high voltage power supply for magnetrons, used for the microwave generators in industrial applications. The design of this system is composed of a new three-phase leakage flux transformer supplying by phase a cell, composed of a capacitor and a diode, which multiplies the voltage and stabilizes the current. Each cell. in turn, supplies a single magnetron. An equivalent model of this transformer is developed taking into account the saturation phenomenon and the stabilization process of each magnetron. Each inductance of the model is characterized by a non linear relation between flux and current. This model was tested by EMTP software near the nominal state. The theoretical results were compared to experimental measurements with a good agreement. Relative to the current device, the new systemprovides gains of size, volume, cost of implementation and maintenance which make it more economical.

  6. Heat transfer modelling of two-phase bubbles swarm condensing in three - phase direct - contact condenser

    Directory of Open Access Journals (Sweden)

    Mahood Hameed B.

    2016-01-01

    Full Text Available An analytical model for the convective heat transfer coefficient and the two-phase bubble size of a three-phase direct contact heat exchanger was developed. Until the present, there has only been a theoretical model available that deals with a single two-phase bubble and a bubble train condensation in an immiscible liquid. However, to understand the actual heat transfer process within the three-phase direct contact condenser, characteristic models are required. A quasi - steady energy equation in a spherical coordinate system with a potential flow assumption and a cell model configuration has been simplified and solved analytically. The convective heat transfer in terms of Nu number has been derived, and it was found to be a function to Pe number and a system void fraction. In addition, the two-phase bubble size relates to the system void fraction and has been developed by solving a simple energy balance equation and using the derived convective heat transfer coefficient expression. Furthermore, the model correlates well with previous experimental data and theoretical results.

  7. Positioning graphical objects on computer screens: a three-phase model.

    Science.gov (United States)

    Pastel, Robert

    2011-02-01

    This experiment identifies and models phases during the positioning of graphical objects (called cursors in this article) on computer displays. The human computer-interaction community has traditionally used Fitts' law to model selection in graphical user interfaces, whereas human factors experiments have found the single-component Fitts' law inadequate to model positioning of real objects. Participants (N=145) repeatedly positioned variably sized square cursors within variably sized rectangular targets using computer mice. The times for the cursor to just touch the target, for the cursor to enter the target, and for participants to indicate positioning completion were observed. The positioning tolerances were varied from very precise and difficult to imprecise and easy. The time for the cursor to touch the target was proportional to the initial cursor-target distance. The time for the cursor to completely enter the target after touching was proportional to the logarithms of cursor size divided by target tolerances. The time for participants to indicate positioning after entering was inversely proportional to the tolerance. A three-phase model defined by regions--distant, proximate, and inside the target--was proposed and could model the positioning tasks. The three-phase model provides a framework for ergonomists to evaluate new positioning techniques and can explain their deficiencies. The model provides a means to analyze tasks and enhance interaction during positioning.

  8. Three-Phase Time-Multiplexed Planar Power Transmission to Distributed Implants.

    Science.gov (United States)

    Lee, Byunghun; Ahn, Dukju; Ghovanloo, Maysam

    2016-03-01

    A platform has been presented for wireless powering of receivers (Rx's) that are arbitrarily distributed over a large area. A potential application could be powering of small Rx implants, distributed over large areas of the brain. The transmitter (Tx) consists of three overlapping layers of hexagonal planar spiral coils (hex-PSC) that are horizontally shifted to provide the strongest and most homogeneous electromagnetic flux coverage. The three-layer hex-PSC array is driven by a three-phase time-division-multiplexed power Tx that takes the advantage of the carrier phase shift, coil geometries, and Rx time constant to homogeneously power the arbitrarily distributed Rx's regardless of their misalignments. The functionality of the proposed three-phase power transmission concept has been verified in a detailed scaled-up high-frequency structure simulator Advanced Design System simulation model and measurement setup, and compared with a conventional Tx. The new Tx delivers 5.4 mW to each Rx and achieves, on average, 5.8% power transfer efficiency to the Rx at the worst case 90° angular misalignment, compared with 1.4% by the conventional Tx.

  9. Noise and Vibration Monitoring for Premium Efficiency IE 3 Three-Phase Induction Motors

    Directory of Open Access Journals (Sweden)

    NISTOR, C. G.

    2015-08-01

    Full Text Available The paper presents the original SV-100 platform that enables low-cost and very high accuracy determinations of noise and vibration levels. The aim of the proposed platform is to achieve an effective integration of the two topics of this analysis: vibrations and noises. To the best of our knowledge, no low price, dedicated compact platform with embedded measuring instruments exists. For proving the practical utility of the proposed platform, two induction motors of 7.5 kW and 11 kW, respectively, in single-layer winding, at 1000 rpm, with IE3 premium efficiency were analyzed. This analysis is required because, according to IEC60034-30 standard, the IE3 efficiency standard has become mandatory for induction motors of rated power greater than 7.5 kW. Therefore, in order to improve the motor operating efficiency, the power losses caused by noises and vibrations have to be reduced. Several variants of supply were studied, i.e., by the three-phase 50 Hz network and by a three-phase inverter at 40, 50 and 60 Hz, respectively. The experimental determinations of noises are presented comparatively, by using a Bruel&Kjaer sonometer and by using the new platform SV-100. The results are compared with the IEC60034 standard.

  10. Simulation of three-phase induction motor drives using indirect field oriented control in PSIM environment

    Science.gov (United States)

    Aziri, Hasif; Patakor, Fizatul Aini; Sulaiman, Marizan; Salleh, Zulhisyam

    2017-09-01

    This paper presents the simulation of three-phase induction motor drives using Indirect Field Oriented Control (IFOC) in PSIM environment. The asynchronous machine is well known about natural limitations fact of highly nonlinearity and complexity of motor model. In order to resolve these problems, the IFOC is applied to control the instantaneous electrical quantities such as torque and flux component. As FOC is controlling the stator current that represented by a vector, the torque component is aligned with d coordinate while the flux component is aligned with q coordinate. There are five levels of the incremental system are gradually built up to verify and testing the software module in the system. Indeed, all of system build levels are verified and successfully tested in PSIM environment. Moreover, the corresponding system of five build levels are simulated in PSIM environment which is user-friendly for simulation studies in order to explore the performance of speed responses based on IFOC algorithm for three-phase induction motor drives.

  11. Completion of a high efficiency ultralarge capacity three-phase transformer

    International Nuclear Information System (INIS)

    Maejima, Masaaki; Maruyama, Katsuya; Fukuda, Teruo.

    1986-01-01

    As for the boosting transformers for thermal and nuclear power stations, at present the ultralarge capacity transformers of 1000 - 1200 MVA class are the main, and particularly in nuclear power, accompanying the development of improved type BWRs and the rise of system stability, there is the tendency toward further large capacity and large size. Consequently, reflecting the recent rise of energy cost, the demand of energy conservation and the reduction of required sites heightened largely as well as the high reliability. In order to meet these demands, Hitachi Ltd. has established the technology of changing to iron machines such as ultralarge iron cores and ultralarge capacity undivided disk windings using the latest design and manufacture techniques were applied to the 525 kV, 1200 MVA transformer for No.4 plant in Fukushima No.2 Nuclear Power Station, Tokyo Electric Power Co., Inc., thus a three-phase transformer of the highest level, high efficiency and ultralarge capacity was completed. In this paper, the outline of this transformer and the test for verifying its reliability are described. The technical change of large capacity three-phase transformers, the specifications, construction, manufacture, reliability test and the effect of modification of this transformer, and the expansion of application to the next generation ultralarge capacity transformers are reported. (Kako, I.)

  12. Alcohol vapour detection at the three phase interface using enzyme-conducting polymer composites.

    Science.gov (United States)

    Winther-Jensen, Orawan; Kerr, Robert; Winther-Jensen, Bjorn

    2014-02-15

    Immobilisation of enzymes on a breathable electrode can be useful for various applications where the three-phase interface between gas or chemical vapour, electrolyte and electrode is crucial for the reaction. In this paper, we report the further development of the breathable electrode concept by immobilisation of alcohol dehydrogenase into vapour-phase polymerised poly(3,4-ethylene dioxythiophene) that has been coated onto a breathable membrane. Typical alcohol sensing, whereby the coenzyme β-Nicotinamide adenine dinucleotide (NADH) is employed as a redox-mediator, was successfully used as a model reaction for the oxidation of ethanol. This indicates that the ethanol vapour from the backside of the membrane has access to the active enzyme embedded in the electrode. The detecting range of the sensor is suitable for the detection of ethanol in fruit juices and for the baseline breath ethanol concentration of drunken driving. After continuous operation for 4.5h the system only showed a 20% decrease in the current output. The electrodes maintained 62% in current output after being refrigerated for 76 days. This work is continuing the progress of the immobilisation of specific enzymes for certain electrochemical reactions whereby the three-phase interface has to be maintained and/or the simultaneous separation of gas from liquid is required. © 2013 Elsevier B.V. All rights reserved.

  13. Direct transformation of solar energy into three-phase current for technical uses

    Energy Technology Data Exchange (ETDEWEB)

    von Hacht, G [Ingenieurbuero Opto-Sensor-Technik, Frankfurt am Main (Germany, F.R.)

    1977-08-01

    The author proposes a method which may increase the 15% efficiency of present solar plants. In principle, the device consists of an optical waveguide tube containing a chain of solar elements. The tube serves as conductive wire for the primary coil of an a.c. or three-phase current transformer. The 50 Hz cycle of the a.c. or three-phase current is generated by rotor or cylindrical diaphragms and/or electronic pilot/thyristor control. The solar energy is focussed axially and/or vertically to the axis of the optical waveguide tube. The light going through the optical waveguide tube makes it possible for solar elements to be equipped with light-sensitive layers on both sides instead of just on one side, as until now. This means a higher efficiency than for conventional solar elements exposed to light only on one side. In addition, the optical waveguide tube is designed in its length as Fabry-Perot resonator. This way, it may also be used as a gas laser. The light generated in this gas laser would multiply the luminous intensity which again acts on the two light-sensitive sides of the solar elements, thus again increasing their efficiency.

  14. MECHANICAL CHARACTERISTICS OF THREE-PHASE INDUCTION MOTORS WITH SINGLE-PHASE POWER SUPPLY

    Directory of Open Access Journals (Sweden)

    V.S. Malyar

    2016-06-01

    Full Text Available Aim. Development of a method for calculating mechanical characteristics of three-phase induction motors with single-phase power supply. Methods. The developed algorithm is based on the high-adequacy mathematical model of motor and projection method for solving the boundary problem for equations of electrical circuits balance presented in the three-phase coordinate system. As a result of asymmetry of power supply to the stator windings, in steady state, flux-linkage and current change according to the periodic law. They are determined by solving the boundary problem. Results. The developed mathematical model allows determining periodic dependence of coordinates as a function of slip and, based on them, mechanical characteristics of motors. Academic novelty. The developed method relies on a completely new mathematical approach to calculation of stationary modes of nonlinear electromagnetic circuits, which allows obtaining periodic solution in a timeless domain. Practical value. Using the developed calculation algorithm, one can select capacitance required to start an induction motor with single-phase power supply and calculate static mechanical characteristics at a given capacitance.

  15. Low-voltage ride-through of a droop-based three-phase four-wire grid-connected microgrid

    DEFF Research Database (Denmark)

    Sadeghkhani, Iman; Golshan, Mohamad Esmail Hamedani; Mehrizi-Sani, Ali

    2018-01-01

    system operations during abnormal grid conditions. The objective of this paper is to propose an LVRT scheme that improves the power quality of the entire microgrid. The developed method is implemented as the controller of the interface voltage-sourced converter (VSC) of a distributed energy resource...... control of each phase and does not require calculation of symmetrical components. Moreover, it can be employed in the VSC control systems with various reference frames and is effective for droop-based grid-connected microgrids with both single-phase and three-phase four-wire configurations. The proposed......The ability of riding through the grid disturbances can increase the integration of microgrids into the distribution system. Consequently, a grid-connected microgrid should provide ancillary services such as low voltage ride-through (LVRT) capability and reactive power support to sustain the power...

  16. Capacitance estimation algorithm based on DC-link voltage harmonics using artificial neural network in three-phase motor drive systems

    DEFF Research Database (Denmark)

    Soliman, Hammam Abdelaal Hammam; Davari, Pooya; Wang, Huai

    2017-01-01

    to industry. In this digest, a condition monitoring methodology that estimates the capacitance value of the dc-link capacitor in a three phase Front-End diode bridge motor drive is proposed. The proposed software methodology is based on Artificial Neural Network (ANN) algorithm. The harmonics of the dc......-link voltage are used as training data to the Artificial Neural Network. Fast Fourier Transform (FFT) of the dc-link voltage is analysed in order to study the impact of capacitance variation on the harmonics order. Laboratory experiments are conducted to validate the proposed methodology and the error analysis......In modern design of power electronic converters, reliability of dc-link capacitors is one of the critical considered aspects. The industrial field have been attracted to the monitoring of their health condition and the estimation of their ageing process status. However, the existing condition...

  17. Fault Diagnosis of Three Phase Induction Motor Using Current Signal, MSAF-Ratio15 and Selected Classifiers

    Directory of Open Access Journals (Sweden)

    Glowacz A.

    2017-12-01

    Full Text Available A degradation of metallurgical equipment is normal process depended on time. Some factors such as: operation process, friction, high temperature can accelerate the degradation process of metallurgical equipment. In this paper the authors analyzed three phase induction motors. These motors are common used in the metallurgy industry, for example in conveyor belt. The diagnostics of such motors is essential. An early detection of faults prevents financial loss and downtimes. The authors proposed a technique of fault diagnosis based on recognition of currents. The authors analyzed 4 states of three phase induction motor: healthy three phase induction motor, three phase induction motor with 1 faulty rotor bar, three phase induction motor with 2 faulty rotor bars, three phase induction motor with faulty ring of squirrel-cage. An analysis was carried out for original method of feature extraction called MSAF-RATIO15 (Method of Selection of Amplitudes of Frequencies – Ratio 15% of maximum of amplitude. A classification of feature vectors was performed by Bayes classifier, Linear Discriminant Analysis (LDA and Nearest Neighbour classifier. The proposed technique of fault diagnosis can be used for protection of three phase induction motors and other rotating electrical machines. In the near future the authors will analyze other motors and faults. There is also idea to use thermal, acoustic, electrical, vibration signal together.

  18. Research on Two-channel Interleaved Two-stage Paralleled Buck DC-DC Converter for Plasma Cutting Power Supply

    DEFF Research Database (Denmark)

    Yang, Xi-jun; Qu, Hao; Yao, Chen

    2014-01-01

    As for high power plasma power supply, due to high efficiency and flexibility, multi-channel interleaved multi-stage paralleled Buck DC-DC Converter becomes the first choice. In the paper, two-channel interleaved two- stage paralleled Buck DC-DC Converter powered by three-phase AC power supply...

  19. Examples of digital simulation of AC-DC power converter with the Electromagnetic Transients Program

    International Nuclear Information System (INIS)

    Tanahashi, Shugo; Yamada, Shuichi; Mugishima, Mituo; Kitagawa, Shiro.

    1989-03-01

    This article gives a practical guidance for analysis of power converter circuits using the Electromagnetic Transients Program (EMTP). First how to use the program is shown with two simple examples; (1) a power supply with three-phase diode bridge and (2) a feedback system for current control. Then its application to more complicated system is shown with an example of a power supply for Compact Helical System (CHS), where a hybrid power supply with multi-phase diode and thyristor bridges, and two three-phase thyristor converters are driven by an AC generator. (author)

  20. Current Control of Grid Converters Connected with Series AC Capacitor

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    The series ac capacitor has recently been used with the transformerless grid-connected converters in the distribution power grids. The capacitive characteristic of the resulting series LC filter restricts the use of conventional synchronous integral or stationary resonant current controllers. Thus...... this paper proposes a fourth-order resonant controller in the stationary frame, which guarantees a zero steady-state current tracking error for the grid converters with series LC filter. This method is then implemented in a three-phase experimental system for verification, where the current harmonics below...... the LC filter resonance frequency are effectively eliminated. Experimental results confirm the validity of the proposed current control scheme....

  1. Frequency Adaptive Repetitive Control of Grid-Tied Three-Phase PV Inverters

    DEFF Research Database (Denmark)

    Zhou, Keliang; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    Repetitive control offers an accurate current control scheme for grid-tied converters to feed high quality sinusoidal current into the grid. However, with grid frequency being treated as a constant value, conventional repetitive controller fail to produce high quality feeding current in the prese......Repetitive control offers an accurate current control scheme for grid-tied converters to feed high quality sinusoidal current into the grid. However, with grid frequency being treated as a constant value, conventional repetitive controller fail to produce high quality feeding current...

  2. ITER convertible blanket evaluation

    International Nuclear Information System (INIS)

    Wong, C.P.C.; Cheng, E.

    1995-01-01

    Proposed International Thermonuclear Experimental Reactor (ITER) convertible blankets were reviewed. Key design difficulties were identified. A new particle filter concept is introduced and key performance parameters estimated. Results show that this particle filter concept can satisfy all of the convertible blanket design requirements except the generic issue of Be blanket lifetime. If the convertible blanket is an acceptable approach for ITER operation, this particle filter option should be a strong candidate

  3. High power density dc/dc converter: Selection of converter topology

    Science.gov (United States)

    Divan, Deepakraj M.

    1990-01-01

    The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

  4. Power converters definitions, classification and converter topologies

    CERN Document Server

    Bordry, Frederick

    2006-01-01

    This paper introduces power conversion principles and defines the terminology. The concepts of sources and switches are defined and classified. From the basic laws of source interconnections, a generic method of power converter synthesis is presented. Some examples illustrate this systematic method. Finally, the notions of commutation cell and soft commutation are introduced and discussed.

  5. On network coding and modulation mapping for three-phase bidirectional relaying

    KAUST Repository

    Chang, Ronald Y.; Lin, Sian Jheng; Chung, Wei-Ho

    2015-01-01

    © 2015 IEEE. In this paper, we consider the network coding (NC) enabled three-phase protocol for information exchange between two users in a wireless two-way (bidirectional) relay network. Modulo-based (nonbinary) and XOR-based (binary) NC schemes are considered as information mixture schemes at the relay while all transmissions adopt pulse amplitude modulation (PAM). We first obtain the optimal constellation mapping at the relay that maximizes the decoding performance at the users for each NC scheme. Then, we compare the two NC schemes, each in conjunction with the optimal constellation mapping at the relay, in different conditions. Our results demonstrate that, in the low SNR regime, binary NC outperforms nonbinary NC with 4-PAM, while they have mixed performance with 8-PAM. This observation applies to quadrature amplitude modulation (QAM) composed of two parallel PAMs.

  6. Absorption in a three-phase fluidized bed I: Hydrodynamic investigations

    Directory of Open Access Journals (Sweden)

    Pejanović Srđan M.

    2003-01-01

    Full Text Available The hydrodynamic properties of a three phase fluidized bed with low density inert spherical packing, fluidized by the interaction of a gas flowing upwards and a liquid flowing downwards through the column, were investigated. It was found that the pressure drop, liquid hold up and dynamic bed height increase with both increasing liquid and gas flow rate. While the dynamic bed height and minimum fluidization velocity remain unchanged, both the pressure drop and liquid hold up increase with increasing density of the packing. Therefore, an increase in packing density causes more intensive mass transfer between the fluid phases than packed columns. It was shown that increase of the liquid flow rate causes an increase of both the effective liquid and gas velocity through the fluidized bed, which may also improve mass transfer.

  7. Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions

    Directory of Open Access Journals (Sweden)

    Z. Chelli

    2015-01-01

    Full Text Available This paper focuses on a four-wire shunt active power filter (APF control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation strategy. The developed algorithm is validated by simulation tests using MATLAB Simulink. The obtained results have demonstrated the effectiveness of the proposed scheme and confirmed the theoretical developments for balanced and unbalanced nonlinear loads.

  8. A Navier-Stokes/Cahn-Hilliard model for the simulation of three phase immiscible incompressible flows

    International Nuclear Information System (INIS)

    Celine Lapuerta; Bruno Piar; Franck Boyer; Philippe Angot; Michel Quintard

    2005-01-01

    This paper presents a Navier-Stokes/Cahn-Hilliard model designed for incompressible flows of three immiscible phases, characterized by different surface tensions and without phase change. This physical context is relevant to study the late phase of a hypothetical severe accident in a nuclear pressurized water reactor. Thanks to a suitable choice of a free energy and a particular form of the Cahn-Hilliard equation, the evolution of the three phases is described by only two order parameters. Moreover, this model allows the simulation of purely two phase flows as a limiting case: no artificial apparition of the third phase occurs if this later is physically absent which contrasts with others models of the literature. We examine the spreading of a liquid lens at the interface between two stratified phases. We present results showing that the method gives correct contact angles and pressure jumps, at equilibrium. (authors)

  9. High efficiency and long life of a three-phase power conditioner via interleave control

    Directory of Open Access Journals (Sweden)

    Kenji Amei

    2016-01-01

    Full Text Available This study describes the high efficiency and long life of three-phase power conditioners of a photovoltaic (PV system. The current PV system, which is widely spread, has two problems. The first problem is the lifetime of a power conditioner, whereas the other problem is the drop in the efficiency of the conversion because of the characteristics of the solar cell. For those problems, the solar panel and boost chopper circuit were divided into a plurality to configure a power conditioner, and an electrolytic capacitor-less driver with interleave control was realized. The drop in the current generated by the solar cell was suppressed, and an improvement in power generation efficiency was expected. The configuration and principle of a proposed circuit were explained, and results of simulation and experiment were reported.

  10. Three-Phase Melting Curves in the Binary System of Carbon Dioxide and Water

    Science.gov (United States)

    Abramson, E. H.

    2017-10-01

    Invariant, three-phase melting curves, of ice VI in equilibrium with solid CO2, of ice VII in equilibrium with solid CO2, and of solid CO2 in simultaneous equilibrium with a majority aqueous and a majority CO2 fluid, were explored in the binary system of carbon dioxide and water. Diamond-anvil cells were used to develop pressures of 5 GPa. Water exhibits a large melting temperature depression (73°C less than its pure melting temperature of 253°C at 5 GPa) indicative of large concentrations of CO2 in the aqueous solution. The melting point of water-saturated CO2 does not show a measureable departure from that of the pure system at temperatures lower than ∼200°C and only 10°C at 5 GPa (from 327°C).

  11. Modeling of a three-phase reactor for bitumen-derived gas oil hydrotreating

    International Nuclear Information System (INIS)

    Chacon, R.; Canale, A.; Bouza, A.; Sanchez, Y.

    2012-01-01

    A three-phase reactor model for describing the hydrotreating reactions of bitumen-derived gas oil was developed. The model incorporates the mass-transfer resistance at the gas-liquid and liquid-solid interfaces and a kinetic rate expression based on a Langmuir-Hinshelwood-type model. We derived three correlations for determining the solubility of hydrogen (H 2 ), hydrogen sulfide (H 2 S) and ammonia (NH 3 ) in hydrocarbon mixtures and the calculation of the catalyst effectiveness factor was included. Experimental data taken from the literature were used to determine the kinetic parameters (stoichiometric coefficients, reaction orders, reaction rate and adsorption constants for hydrodesulfuration (HDS) and hydrodenitrogenation (HDN)) and to validate the model under various operating conditions. Finally, we studied the effect of operating conditions such as pressure, temperature, LHSV, H 2 /feed ratio and the inhibiting effect of H 2 S on HDS and NH 3 on HDN. (author)

  12. The three phases of time-limited day-hospital treatment.

    Science.gov (United States)

    Stein, H H; Hirsch, B; Brenman, S; Bataclan, L

    1990-06-01

    The course of treatment in a time-limited day-hospital setting can be usefully understood in terms of three phases. Close examination of the treatment goals, difficulties, benefits, and tasks for both patients and staff for each phase provides a greater understanding of the curative process. These observations are based upon clinical work in a Veteran Administration Day Hospital and are reinforced with clinical examples from that work. Identification of these phases of treatment can be put to practical use. Knowing in which phase a patient is working helps staff members focus their thinking. Such an awareness can also help staff members cope with "burnout" over the frustrations that come with a particular phase. Information about these phases has been valuable to patients and their families in helping them understand the course of their treatment.

  13. High accuracy interface characterization of three phase material systems in three dimensions

    DEFF Research Database (Denmark)

    Jørgensen, Peter Stanley; Hansen, Karin Vels; Larsen, Rasmus

    2010-01-01

    Quantification of interface properties such as two phase boundary area and triple phase boundary length is important in the characterization ofmanymaterial microstructures, in particular for solid oxide fuel cell electrodes. Three-dimensional images of these microstructures can be obtained...... by tomography schemes such as focused ion beam serial sectioning or micro-computed tomography. We present a high accuracy method of calculating two phase surface areas and triple phase length of triple phase systems from subvoxel accuracy segmentations of constituent phases. The method performs a three phase...... polygonization of the interface boundaries which results in a non-manifold mesh of connected faces. We show how the triple phase boundaries can be extracted as connected curve loops without branches. The accuracy of the method is analyzed by calculations on geometrical primitives...

  14. A new PWM algorithm for battery-source three-phase inverters

    Energy Technology Data Exchange (ETDEWEB)

    Chan, C.C. (Dept. of Electrical and Electronic Engineering, Univ. of Hong Kong, Pokfulam Road (HK)); Chau, K.T. (Dept. of Electrical Engineering, Hong Kong Polytechnic, Hung Hom (HK))

    1991-01-01

    A new PWM algorithm for battery-source three-phase inverters is described in this paper. The concept of the algorithm is to determine the pulsewidths by equating the areas of the segments of the sinusodial reference with the related output pulse areas. The algorithm is particularly suitable to handle a non-constant voltage source with good harmonic suppression. Since the pulsewidths are computable in real time with minimal storage requirement as well as compact hardware and software, it is especially suitable for single-chip microcomputer implementation. Experimental results show that the single-chip microcomputer Intel 8095-based battery-source inverter can control a 3 kW synchronous motor drive satisfactorily over a frequency range of 2 to 100Hz.

  15. A Coordinate Control Strategy for Circulating Current Suppression in Multiparalleled Three-Phase Inverters

    DEFF Research Database (Denmark)

    Zhang, Xueguang; Wang, Tianyi; Wang, Xiongfei

    2017-01-01

    This paper addresses the zero-sequence circulating current control in the multiparalleled three-phase voltage-source inverters. The model of the zero-sequence circulating current in the N-paralleled (N ≥ 3) inverters is derived. It is shown that the circulating current is not only susceptible...... to the mismatches of circuit parameters, but it is also influenced by the interactions of circulating current controllers used by other paralleled inverters. To eliminate these adverse effects on the circulating current control loop, a coordinate control strategy for the N-paralleled inverter is proposed based...... on the zero-vector feedforward method with the space-vector pulse width modulation. Moreover, a virtual inverter method is introduced to facilitate the implementation of the proposed controller, which decouples the interactions of circulating current controllers in the paralleled inverters. Finally...

  16. Renewable Distributed Generation Models in Three-Phase Load Flow Analysis for Smart Grid

    Directory of Open Access Journals (Sweden)

    K. M. Nor

    2013-11-01

    Full Text Available The paper presents renewable distributed generation  (RDG models as three-phase resource in load flow computation and analyzes their effect when they are connected in composite networks. The RDG models that have been considered comprise of photovoltaic (PV and wind turbine generation (WTG. The voltage-controlled node and complex power injection node are used in the models. These improvement models are suitable for smart grid power system analysis. The combination of IEEE transmission and distribution data used to test and analyze the algorithm in solving balanced/unbalanced active systems. The combination of IEEE transmission data and IEEE test feeder are used to test the the algorithm for balanced and unbalanced multi-phase distribution system problem. The simulation results show that by increased number and size of RDG units have improved voltage profile and reduced system losses.

  17. Four quadrant control circuit for a brushless three-phase dc motor

    Science.gov (United States)

    Nola, Frank J. (Inventor)

    1987-01-01

    A control circuit is provided for a brushless three-phase dc motor which affords four quadrant control from a single command. The control circuit probes acceleration of the motor in both clockwise and counterclockwise directions and braking and generation in both clockwise and counterclockwise directions. In addition to turning on individual transistors of the transistor pairs connected to the phase windings of the motor for 120 deg periods while the other transistor of that pair is off, the control circuit also provides, in a future mode of operation, turning the two transistors of each pair on and off alternately at a phase modulation frequency during such a 120 deg period. A feedback signal is derived which is proportional to the motor current and which has a polarity consistent with the command signal, such that negative feedback results.

  18. Optical measuring techniques and their application to two-phase and three-phase flows

    International Nuclear Information System (INIS)

    Liu Xiaozhi.

    1992-01-01

    First of all it is shown that by an optical system based on the Laser-Doppler technology, which uses a pair of cylindrical waves and two optical detectors, the particle size, speed and refractive index can be measured by means of the signal frequencies. The second optical method to characterize spherical particles in a multi-phase flow is an extended phase-Doppler system. By means of an additional pair of photodetectors it has been possible for the first time to measure the refractive index in addition to speed and particle size. The last part of the paper shows that by a special phase-Doppler anemometry system with only two detectors it is also possible to distinguish between reflecting and refractive particles. By means of such PDA system measurements were made in a gas-fluid-solid three-phase flow directed vertically upwards. (orig./DG) [de

  19. Stability of operation versus temperature of a three-phase clock-driven chaotic circuit

    International Nuclear Information System (INIS)

    Zhou Ji-Chao; Son Hyunsik; Song Han Jung; Kim Namtae

    2013-01-01

    We evaluate the influence of temperature on the behavior of a three-phase clock-driven metal—oxide—semiconductor (MOS) chaotic circuit. The chaotic circuit consists of two nonlinear functions, a level shifter, and three sample and hold blocks. It is necessary to analyze a CMOS-based chaotic circuit with respect to variation in temperature for stability because the circuit is sensitive to the behavior of the circuit design parameters. The temperature dependence of the proposed chaotic circuit is investigated via the simulation program with integrated circuit emphasis (SPICE) using 0.6-μm CMOS process technology with a 5-V power supply and a 20-kHz clock frequency. The simulation results demonstrate the effects of temperature on the chaotic dynamics of the proposed chaotic circuit. The time series, frequency spectra, bifurcation phenomena, and Lyapunov exponent results are provided. (general)

  20. ANN based controller for three phase four leg shunt active filter for power quality improvement

    Directory of Open Access Journals (Sweden)

    J. Jayachandran

    2016-03-01

    Full Text Available In this paper, an artificial neural network (ANN based one cycle control (OCC strategy is proposed for the DSTATCOM shunted across the load in three phase four wire distribution system. The proposed control strategy mitigates harmonic/reactive currents, ensures balanced and sinusoidal source current from the supply mains that are nearly in phase with the supply voltage and compensates neutral current under varying source and load conditions. The proposed control strategy is superior over conventional methods as it eliminates, the sensors needed for sensing load current and coupling inductor current, in addition to the multipliers and the calculation of reference currents. ANN controllers are implemented to maintain voltage across the capacitor and as a compensator to compensate neutral current. The DSTATCOM performance is validated for all possible conditions of source and load by simulation using MATLAB software and simulation results prove the efficacy of the proposed control over conventional control strategy.

  1. Microcontroller based PWM controlled four switch three phase inverter fed induction motor drive

    Directory of Open Access Journals (Sweden)

    Mohanty Kant Nalin

    2010-01-01

    Full Text Available This paper presents PIC microcontroller based PWM inverter controlled four switch three phase inverter (FSTPI fed Induction Motor drive. The advantage of this inverter that uses of 4 switches instead of conventional 6 switches is lesser switching losses, lower electromagnetic interference (EMI, less complexity of control algorithms and reduced interface circuits. Simulation and experimental work are carried out and results presented to demonstrate the feasibility of the proposed approach. Simulation is carried out using MATLAB SIMULINK and in the experimental work a prototype model is built to verify the simulation results. PIC microcontroller (PIC 16F877A is used to generate the PWM pulses for FSTPI to drive the 0.5 hp 3-phase Induction Motor.

  2. Design and control of an LCL-filter-based three-phase active rectifier

    DEFF Research Database (Denmark)

    Liserre, Marco; Blaabjerg, Frede; Hansen, Steffan

    2005-01-01

    This paper proposes a step-by-step procedure for designing the LCL filter of a front-end three-phase active rectifier. The primary goal is to reduce the switching frequency ripple at a reasonable cost, while at the same time achieving a high-performance front-end rectifier (as characterized...... by a rapid dynamic response and good stability margin). An example LCL filter design is reported and a filter has been built and tested using the values obtained from this design. The experimental results demonstrate the performance of the design procedure both for the LCL filter and for the rectifier...... a powerful tool to design an LCL-filter-based active rectifier while avoiding trial-and-error procedures that can result in having to build several filter prototypes....

  3. Sliding three-phase contact line of printed droplets for single-crystal arrays

    International Nuclear Information System (INIS)

    Kuang, Minxuan; Wu, Lei; Li, Yifan; Gao, Meng; Zhang, Xingye; Jiang, Lei; Song, Yanlin

    2016-01-01

    Controlling the behaviours of printed droplets is an essential requirement for inkjet printing of delicate three-dimensional (3D) structures or high-resolution patterns. In this work, molecular deposition and crystallization are regulated by manipulating the three-phase contact line (TCL) behaviour of the printed droplets. The results show that oriented single-crystal arrays are fabricated based on the continuously sliding TCL. Owing to the sliding of the TCL on the substrate, the outward capillary flow within the evaporating droplet is suppressed and the molecules are brought to the centre of the droplet, resulting in the formation of a single crystal. This work provides a facile strategy for controlling the structures of printed units by manipulating the TCL of printed droplets, which is significant for realizing high-resolution patterns and delicate 3D structures. (paper)

  4. Design and Control of Parallel Three Phase Voltage Source Inverters in Low Voltage AC Microgrid

    Directory of Open Access Journals (Sweden)

    El Hassane Margoum

    2017-01-01

    Full Text Available Design and hierarchical control of three phase parallel Voltage Source Inverters are developed in this paper. The control scheme is based on synchronous reference frame and consists of primary and secondary control levels. The primary control consists of the droop control and the virtual output impedance loops. This control level is designed to share the active and reactive power correctly between the connected VSIs in order to avoid the undesired circulating current and overload of the connected VSIs. The secondary control is designed to clear the magnitude and the frequency deviations caused by the primary control. The control structure is validated through dynamics simulations.The obtained results demonstrate the effectiveness of the control structure.

  5. Comparative Study of Fault Diagnostic Methods in Voltage Source Inverter Fed Three Phase Induction Motor Drive

    Science.gov (United States)

    Dhumale, R. B.; Lokhande, S. D.

    2017-05-01

    Three phase Pulse Width Modulation inverter plays vital role in industrial applications. The performance of inverter demeans as several types of faults take place in it. The widely used switching devices in power electronics are Insulated Gate Bipolar Transistors (IGBTs) and Metal Oxide Field Effect Transistors (MOSFET). The IGBTs faults are broadly classified as base or collector open circuit fault, misfiring fault and short circuit fault. To develop consistency and performance of inverter, knowledge of fault mode is extremely important. This paper presents the comparative study of IGBTs fault diagnosis. Experimental set up is implemented for data acquisition under various faulty and healthy conditions. Recent methods are executed using MATLAB-Simulink and compared using key parameters like average accuracy, fault detection time, implementation efforts, threshold dependency, and detection parameter, resistivity against noise and load dependency.

  6. Power-Quality-Oriented Optimization in Multiple Three-Phase Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Yang, Yongheng; Davari, Pooya; Blaabjerg, Frede

    2016-01-01

    As an almost standardized configuration, Diode Rectifiers (DRs) and Silicon-Controlled Rectifiers (SCRs) are commonly employed as the front-end topology in three-phase Adjustable Speed Drive (ASD) systems. Features of this ASD configuration include: structural and control simplicity, small volume......, low cost, and high reliability during operation. Yet, DRs and SCRs bring harmonic distortions in the mains and thus lowering the overall efficiency. Power quality standards/rules are thus released. For multiple ASD systems, certain harmonics of the total grid current can be mitigated by phase......-shifting the currents drawn by SCR-fed drives, and thus it is much flexible to reduce the Total Harmonic Distortion (THD) level in such applications. However, the effectiveness of this harmonic mitigation scheme for multiple ASD systems depends on: a) the number of parallel drives, b) the power levels, and c...

  7. Estimated D2--DT--T2 phase diagram in the three-phase region

    International Nuclear Information System (INIS)

    Souers, P.C.; Hickman, R.G.; Tsugawa, R.T.

    1976-01-01

    A composite of experimental eH 2 -D 2 phase-diagram data at the three-phase line is assembled from the literature. The phase diagram is a smooth cigar shape without a eutectic point, indicating complete miscibility of liquid and solid phases. Additional data is used to estimate the D 2 -T 2 , D 2 DT, and DT-T 2 binary phase diagrams. These are assembled into the ternary D 2 -DT-T 2 phase diagram. A surface representing the chemical equilibrium of the three species is added to the phase diagram. At chemical equilibrium, it is estimated that 50-50 liquid D-T at 19.7 0 K is in equilibrium with 42 mole percent T vapor and 54 percent T solid. Infrared spectroscopy is suggested as a means of component analysis of liquid and solid mixtures

  8. Real time EM waves monitoring system for oil industry three phase flow measurement

    International Nuclear Information System (INIS)

    Al-Hajeri, S; Wylie, S R; Shaw, A; Al-Shamma'a, A I

    2009-01-01

    Monitoring fluid flow in a dynamic pipeline is a significant problem in the oil industry. In order to manage oil field wells efficiently, the oil industry requires accurate on line sensors to monitor the oil, gas, and water flow in the production pipelines. This paper describes a non-intrusive sensor that is based on an EM Waves cavity resonator. It determines and monitors the percentage volumes of each phase of three phase (oil, gas, and water) in the pipeline, using the resonant frequencies shifts that occur within an electromagnetic cavity resonator. A laboratory prototype version of the sensor system was constructed, and the experimental results were compared to the simulation results which were obtained by the use of High Frequency Structure Simulation (HFSS) software package.

  9. Determining the magnetically nonlinear characteristics of a three phase core-type power transformer

    International Nuclear Information System (INIS)

    Dolinar, Matjaz; Stumberger, Gorazd; Polajzer, Bostjan; Dolinar, Drago

    2006-01-01

    This paper presents nonlinear iron core model of a three-phase, three-limb power transformer which is given by the current-dependant characteristics of flux linkages. The magnetically nonlinear characteristics are determined by controlled magnetic excitation of all three limbs which allows to take into account the variable magnetic-cross couplings between different coils placed on limbs, caused by saturation. The corresponding partial derivatives of measured flux linkage characteristics are used in the transformer circuit model as a magnetically nonlinear iron core model in order to analyze the behaviour of a nonsymmetrically excited transformer. Numerical results using transformer model with the determined iron core model agree very well with the measured results

  10. On network coding and modulation mapping for three-phase bidirectional relaying

    KAUST Repository

    Chang, Ronald Y.

    2015-12-03

    © 2015 IEEE. In this paper, we consider the network coding (NC) enabled three-phase protocol for information exchange between two users in a wireless two-way (bidirectional) relay network. Modulo-based (nonbinary) and XOR-based (binary) NC schemes are considered as information mixture schemes at the relay while all transmissions adopt pulse amplitude modulation (PAM). We first obtain the optimal constellation mapping at the relay that maximizes the decoding performance at the users for each NC scheme. Then, we compare the two NC schemes, each in conjunction with the optimal constellation mapping at the relay, in different conditions. Our results demonstrate that, in the low SNR regime, binary NC outperforms nonbinary NC with 4-PAM, while they have mixed performance with 8-PAM. This observation applies to quadrature amplitude modulation (QAM) composed of two parallel PAMs.

  11. High-frequency, three-phase current controller implementation in an FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M.; Round, S. D.; Kolar, J. W.

    2008-07-01

    Three phase rectifiers with switching frequencies of 500 kHz or more require high speed current controllers. At such high switching frequencies analog controllers as well as high speed digital signal processing (DSP) systems have limited performance. In this paper, two high speed current controller implementations using two different field-programmable gate arrays (FPGA) - one for switching frequencies up to 1 MHz and one for switching frequencies beyond 1 MHz - are presented to overcome this performance limitation. Starting with the digital system design all the blocks of the signal chain, containing analog-to-digital (A/D) interface, digital controller implementation using HW-multipliers and implementation of a novel high speed, high resolution pulse width modulation (PWM) are discussed and compared. Final measurements verify the performance of the controllers. (author)

  12. Fault Diagnosis of Low-Power Three-Phase Induction Motor

    Directory of Open Access Journals (Sweden)

    Gedzurs Aleksejs

    2016-12-01

    Full Text Available An Induction motor reliability survey at an egg processing plant shows that almost 50% of the total motor failures are fan induction motors. Visual investigations of the faulty fan motors show that the main cause of the induction motor failure is air gap eccentricity. In this study, experimental tests are performed on a 1.1kW three-phase induction motor to detect air gap eccentricity and overheating of the induction motor. Heating tests show that end shield housing temperature reaches 100°C with blocked air flow from the fan, which can reduce the lifespan of the bearing. Dimension measurements of the end shield housing show that the dimensions of both tested motors back-end shields are larger than ISO tolerance grade limit. It leads to a loose fit between the housing and bearing, causing air gap eccentricity. Also, both motor back end shield housing has an out-of-round condition leading to an unbalanced magnetic pull. To detect the air gap eccentricity caused by too loose of a fit between housing bore and bearing, current Park’s vector approach is used. To measure three phase current, Hall Effect current transducers, a digital oscilloscope is used and Matlab software to process the measurement data. Results show that Park’s vector approach can be used to detect the air gap eccentricity caused by too loose a fit between bearing and housing. Therefore, the Park’s vector approach can be used to diagnose air gap eccentricity and analyse the type of the air gap eccentricity.

  13. An improved modulation strategy for the three-phase Z-source inverters (ZSIs)

    DEFF Research Database (Denmark)

    Abdelhakim, Ahmed; Davari, Pooya; Blaabjerg, Frede

    2017-01-01

    Z-source inverters (ZSIs), compared to the two-stage architecture, i.e. boost-converter (BC)-fed voltage source inverter (VSI), embrace some interesting features, like the reduced size and complexity of the entire conversion system. Several research activities have been established to improve...

  14. Performance Evaluation of Three-Level Z-Source Inverters Under Semiconductor-Failure Conditions

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2009-01-01

    This paper evaluates and proposes various compensation methods for three-level Z-source inverters under semiconductor-failure conditions. Unlike the fault-tolerant techniques used in traditional three-level inverters, where either an extra phase-leg or collective switching states are used......, the proposed methods for three-level Z-source inverters simply reconfigure their relevant gating signals so as to ride-through the failed semiconductor conditions smoothly without any significant decrease in their ac-output quality and amplitude. These features are partly attributed to the inherent boost...... under semiconductor-failure conditions. For verifying these described performance features, PLECS simulation and experimental testing were performed with some results captured and shown in a later section for visual confirmation....

  15. Topological Design and Modulation Strategy for Buck-Boost Three-Level Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus

    2009-01-01

    To date, designed topologies for dc-ac inversion with both voltage buck and boost capabilities are mainly focused on two-level circuitries with extensions to three-level possibilities left nearly unexplored. Contributing to this area of research, this paper presents the design of a number of viable...... can perform distinct five-level line voltage and three-level phase voltage switching by simply controlling the active switches located in the designed voltage boost section of the circuits. As a cost saving option, one active switch can further be removed from the voltage boost section of the circuits...... buck-boost threelevel inverters that can also support bidirectional power conversion. The proposed front-end circuitry is developed from the C´ ukderived buck-boost two-level inverter, and by using the "alternative phase opposition disposition" modulation scheme, the buck-boost three-level inverters...

  16. Enhanced Buck-Boost Three-Level Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Tan, K. K.; Gao, F.; Chiang Loh, Poh

    2009-01-01

    In traditional three-level neutral-point-clamped (NPC) inverters, a major issue is capacitor voltage imbalance, which results in low order harmonics. The compensation of the capacitor voltages often require additional control complexity, which cannot be conveniently implemented. The "alternative...... phase opposition disposition" (APOD) modulation method used in traditional NPC topologies also has lower harmonics performance as compared to the "phase disposition" (PD) modulation method.In this paper, we introduce a new three-level NPC topology that utilises the harmonically superior PD modulation...... method, with the ability to easily adjust for capacitor voltage imbalances. To further improve the boost capability of the three-level NPC inverters, another new topology introduces 2 additional diodes,achieving higher boost performance while totally eliminating thepossibility of capacitor voltage...

  17. Quantum iSWAP gate in optical cavities with a cyclic three-level system

    Science.gov (United States)

    Yan, Guo-an; Qiao, Hao-xue; Lu, Hua

    2018-04-01

    In this paper we present a scheme to directly implement the iSWAP gate by passing a cyclic three-level system across a two-mode cavity quantum electrodynamics. In the scheme, a three-level Δ -type atom ensemble prepared in its ground state mediates the interaction between the two-cavity modes. For this theoretical model, we also analyze its performance under practical noise, including spontaneous emission and the decay of the cavity modes. It is shown that our scheme may have a high fidelity under the practical noise.

  18. Impact of Three-Phase Relative Permeability and Hysteresis Models on Forecasts of Storage Associated With CO2-EOR

    Science.gov (United States)

    Jia, Wei; McPherson, Brian; Pan, Feng; Dai, Zhenxue; Moodie, Nathan; Xiao, Ting

    2018-02-01

    Geological CO2 sequestration in conjunction with enhanced oil recovery (CO2-EOR) includes complex multiphase flow processes compared to CO2 storage in deep saline aquifers. Two of the most important factors affecting multiphase flow in CO2-EOR are three-phase relative permeability and associated hysteresis, both of which are difficult to measure and are usually represented by numerical interpolation models. The purpose of this study is to improve understanding of (1) the relative impacts of different three-phase relative permeability models and hysteresis models on CO2 trapping mechanisms, and (2) uncertainty associated with these two factors. Four different three-phase relative permeability models and three hysteresis models were applied to simulations of an active CO2-EOR site, the SACROC unit located in western Texas. To eliminate possible bias of deterministic parameters, we utilized a sequential Gaussian simulation technique to generate 50 realizations to describe heterogeneity of porosity and permeability, based on data obtained from well logs and seismic survey. Simulation results of forecasted CO2 storage suggested that (1) the choice of three-phase relative permeability model and hysteresis model led to noticeable impacts on forecasted CO2 sequestration capacity; (2) impacts of three-phase relative permeability models and hysteresis models on CO2 trapping are small during the CO2-EOR injection period, and increase during the post-EOR CO2 injection period; (3) the specific choice of hysteresis model is more important relative to the choice of three-phase relative permeability model; and (4) using the recommended three-phase WAG (Water-Alternating-Gas) hysteresis model may increase the impact of three-phase relative permeability models and uncertainty due to heterogeneity.

  19. Cascaded resonant bridge converters

    Science.gov (United States)

    Stuart, Thomas A. (Inventor)

    1989-01-01

    A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

  20. Multiple-Complex Coefficient-Filter-Based Phase-Locked Loop and Synchronization Technique for Three-phase Grid-Interfaced Converters in Distributed Utility Networks

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Wu, Weiyang; Chen, Zhe

    2011-01-01

    and rapid extraction of the positive and negative sequence components from the polluted grid voltage, and the harmonic components can also be estimated precisely, which has the potential use for selective compensation in active filter applications. Another advantage of the proposed method is its flexibility...

  1. Evolution of entropy in different types of non-Markovian three-level ...

    Indian Academy of Sciences (India)

    We solve the Nakajima–Zwanzig (NZ) non-Markovian master equation to study the dynamics of different types of three-level atomic systems interacting with bosonic Lorentzian reservoirs at zero temperature. Von Neumann entropy (S) is used to show the evolution of the degree of entanglement of the subsystems.

  2. A three-level framework for performance-based railway timetabling

    DEFF Research Database (Denmark)

    Goverde, Rob M P; Bešinović, Nikola; Binder, Anne

    2016-01-01

    . This paper presents a performance-based railway timetabling framework integrating timetable construction and evaluation on three levels: microscopic, macroscopic, and a corridor fine-tuning level, where each performance indicator is optimized or evaluated at the appropriate level. A modular implementation...

  3. Dynamical symmetry breaking of lambda- and vee-type three-level ...

    Indian Academy of Sciences (India)

    cascade-type three-level configurations using the generators of SU(3) group. ... Quantum optics gave birth to many novel proposals which are within reach of ... Hioe and Eberly, who argued the order of the energy levels to be E1 < E3 < E2.

  4. Elimination of zero sequence circulating current between parallel operating three-level inverters

    DEFF Research Database (Denmark)

    Li, Kai; Wang, Xiaodong; Dong, Zhenhua

    2016-01-01

    In order to suppress the zero sequence circulating currents (ZSCCs) between parallel operating three level voltage source inverters with common AC and DC buses, a common mode voltage reduction PWM (CMVR-PWM) technique and neural point potentials (NPPs) control based method is proposed in this paper...

  5. Synchronised PWM Schemes for Three-level Inverters with Zero Common-mode Voltage

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    This paper presents results of analysis and comparison of novel synchronised schemes of pulsewidth modulation (PWM), applied to three-level voltage source inverters with control algorithms providing elimination of the common-mode voltage. The proposed approach is based on a new strategy of digital...

  6. Neutral-point voltage dynamic model of three-level NPC inverter for reactive load

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, Sergio

    2012-01-01

    A three-level neutral-point-clamped inverter needs a controller for the neutral-point voltage. Typically, the controller design is based on a dynamic model. The dynamic model of the neutral-point voltage depends on the pulse width modulation technique used for the inverter. A pulse width modulati...

  7. A Greedy Heuristic for a Three-Level Multi-Period Single-Sourcing Problem

    NARCIS (Netherlands)

    H.E. Romeijn (Edwin); D. Romero Morales (Dolores)

    2000-01-01

    textabstractIn this paper we consider a model for integrating transportation and inventory decisions in a three-level logistics network consisting of plants, warehouses, and retailers (or customers). Our model includes production and throughout capacity constraints, and minimizes production,

  8. Vacuum-induced stationary entanglement in radiatively coupled three-level atoms

    International Nuclear Information System (INIS)

    Derkacz, Lukasz; Jakobczyk, Lech

    2008-01-01

    We consider a pair of three-level atoms interacting with a common vacuum and analyse the process of entanglement production due to spontaneous emission. We show that in the case of closely separated atoms collective damping can generate robust entanglement of the asymptotic states

  9. Three Levels of Motivation in Instruction: Building Interpersonal Relations with Learners

    Science.gov (United States)

    Cao, Katy Xinquan

    2004-01-01

    Based on the emotions and responsibilities, this paper proposes a model that identifies three levels of motivation (3LOM) in instruction. It states that motivation can be addressed at three different levels: inclusion, entertainment and edification. It looks at motivation from the angle of social interaction. The focus of the model is to describe…

  10. Vacuum-induced stationary entanglement in radiatively coupled three-level atoms

    Energy Technology Data Exchange (ETDEWEB)

    Derkacz, Lukasz; Jakobczyk, Lech [Institute of Theoretical Physics, University of Wroclaw, Plac Maxa Borna 9, 50-204 Wroclaw (Poland)], E-mail: ljak@ift.uni.wroc.pl

    2008-05-23

    We consider a pair of three-level atoms interacting with a common vacuum and analyse the process of entanglement production due to spontaneous emission. We show that in the case of closely separated atoms collective damping can generate robust entanglement of the asymptotic states.

  11. Resonance fluorescence spectra of a three-level atom driven by two strong laser fields

    International Nuclear Information System (INIS)

    Peng Jinsheng.

    1986-12-01

    The resonance fluorescence of a three-level atom interacted with two high-power laser fields is investigated in strong field approximation. The fluorescence distribution is obtained by means of the theory of dressing transformation. (author). 15 refs, 2 figs

  12. Coherent scattering of three-level atoms in the field of a bichromatic standing light wave

    International Nuclear Information System (INIS)

    Pazgalev, A.S.; Rozhdestvenskii, Yu.V.

    1996-01-01

    We discuss the coherent scattering of three-level atoms in the field of two standing light waves for two values of the spatial shift. In the case of a zero spatial shift and equal frequency detunings of the standing waves, the problem of scattering of a three-level atoms is reduced to scattering of an effectively two-level atom. For the case of an exact resonance between the waves and transitions we give expressions for the population probability of the states of the three-level atom obtained in the short-interaction-time approximation. Depending on the initial population distribution over the states, different scattering modes are realized. In particular, we show that there can be initial conditions for which the three-level system does not interact with the field of the standing waves, with the result that there is no coherent scattering of atoms. In the case of standing waves shifted by π/2, there are two types of solution, depending on the values of the frequency detuning. For instance, when the light waves are detuned equally we give the exact solution for arbitrary relationships between the detuning and the standing wave intensities valid for any atom-field interaction times. The case of 'mirror' detunings and shifted standing waves is studied only numerically

  13. Comparing the standard EQ-5D three-level system with a five-level version

    NARCIS (Netherlands)

    Janssen, Mathieu F.; Birnie, Erwin; Haagsma, Juanita A.; Bonsel, Gouke J.

    2008-01-01

    OBJECTIVES: The aim of this study is a head-to-head comparison of the performance of the three-level EQ-5D (3L) and a newly developed five-level version (5L). METHODS: Eighty-two respondents valued 15 standardized disease descriptions and their own health on three response scales (3L, 5L, and visual

  14. Optical gain in an optically driven three-level ? system in atomic Rb vapor

    Science.gov (United States)

    Ballmann, C. W.; Yakovlev, V. V.

    2018-06-01

    In this work, we report experimentally achieved optical gain of a weak probe beam in a three-level ? system in a low density Rubidium vapor cell driven by a single pump beam. The maximum measured gain of the probe beam was about 0.12%. This work could lead to new approaches for enhancing molecular spectroscopy applications.

  15. Toward personalised and dynamic cultural routing: a three-level approach

    NARCIS (Netherlands)

    Aksenov, P.; Kemperman, A.D.A.M.; Arentze, T.A.

    2014-01-01

    This paper introduces the concept of “smart routing” as a recommender system for tourists that takes into account the dynamics of their personal user profiles. The concept relies on three levels of support: 1) programming the tour, i.e. selecting a set of relevant points of interests (POIs) to be

  16. Evolution of entropy in different types of non-Markovian three-level ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 86; Issue 5. Evolution of entropy in different types of non-Markovian three-level systems: Single reservoir vs. two independent reservoirs. JAGHOURI HAKIMEH SARBISHAEI MOHSEN JAVIDAN KUROSH. Regular Volume 86 Issue 5 May 2016 pp 997-1008 ...

  17. Design and implementation of PV-based three-phase four-wire ...

    Indian Academy of Sciences (India)

    Mazouz N and Midoun A 2011 Control of a DC/DC converter by fuzzy controller for a solar pumping system. Int. J Electr Power Energy Syst. 33(10): 1623–1630. Ojo O and Kshirsagar P M 2004 Concise modulation strategies for four-leg voltage source inverters. IEEE. Trans. Power Electron. 19(1): 46–53. Peng F Z and Lai ...

  18. NETWORK-CENTRIC TECHNOLOGIES FOR CONTROL OF THREE-PHASE NETWORK OPERATION MODES

    Directory of Open Access Journals (Sweden)

    Ye. I. Sokol

    2017-06-01

    Full Text Available Purpose. The development of the control system for three-phase network is based on intelligent technologies of network-centric control of heterogeneous objects. The introduction of unmanned aerial vehicles for monitoring of three-phase network increases the efficiency of management. Methodology. The case of decomposition of the instantaneous capacities of the fixed and variable components for 3-wire system. The features of power balance for the different modes of its functioning. It should be noted that symmetric sinusoidal mode is balanced and good, but really unbalanced, if the standard reactive power is not zero. To solve the problem of compensation is sufficient knowledge of the total value of the inactive components of full power (value of the inactive power without detail. The creation of a methodology of measurement and assessment will require knowledge of the magnitudes of each inactive component separately, which leads to the development of a unified approach to the measurement and compensation of inactive components of full power and the development of a generalized theory of power. Results. Procedure for the compensation of the current of zero sequence excludes from circuit the source, as the active component of instantaneous power of zero sequence, and a vector due to a current of zero sequence. This procedure is performed without time delay as it does not require integration. Only a 3–wire system with symmetrical voltage eliminates pulsations and symmetrization of the equivalent conductances of the phases of the task. Under asymmetric voltage, the power is different, its analysis requires the creation of a vector mathematical model of the energy processes of asymmetrical modes of 3–phase systems. Originality. The proposed method extends the basis of the vector method for any zero sequence voltages and shows that the various theories of instantaneous power three wired scheme due to the choice of a basis in a two

  19. SSG Wave Energy Converter

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Vicinanza, Diego; Frigaard, Peter

    2008-01-01

    The SSG (Sea Slot-cone Generator) is a wave energy converter of the overtopping type. The structure consists of a number of reservoirs one on the top of each others above the mean water level, in which the water of incoming waves is stored temporary. In each reservoir, expressively designed low...... head hydroturbines are converting the potential energy of the stored water into power. A key to success for the SSG will be the low cost of the structure and its robustness. The construction of the pilot plant is scheduled and this paper aims to describe the concept of the SSG wave energy converter...

  20. Low sensitivity of three-phase bone scintigraphy for the diagnosis of repetitive strain injury

    Directory of Open Access Journals (Sweden)

    Bárbara Juarez Amorim

    Full Text Available CONTEXT AND OBJECTIVE: The diagnosis of repetitive strain injury (RSI is subjective and solely based on clinical signs and physical examination. The aim of this paper was to assess the usefulness of three-phase bone scintigraphy (TPBS in diagnosing RSI. DESIGN AND SETTING: Prospective study at the Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Universidade Estadual de Campinas (Unicamp. METHODS: Seventy-three patients (mean age 31.2 years; 47 males with clinical suspicion of RSI in the upper limbs were studied. A total of 127 joints with suspicion of RSI were studied. The shoulders, elbows and wrists were analyzed semi-quantitatively, using the shafts of the humeri and ulnae as references. The results were compared with a control group of 40 normal individuals. The patients’ signs and symptoms were used as the "gold standard" for calculating the probabilities. RESULTS: From visual analysis, abnormalities were observed in the flow phase for four joints, in the blood pool phase for 11 joints and in the delayed images for 26 joints. Visual analysis of the joints of the control group did not show any abnormalities. Semi-quantitative analysis showed that most of the patients’ joint ratios were normal. The exceptions were the wrists of patients with left-sided RSI (p = 0.0216. However, the sensitivity (9% and accuracy (41% were very low. CONCLUSION: TPBS with semi-quantitative analysis has very low sensitivity and accuracy in the detection of RSI abnormalities in the upper limbs.

  1. ADVANCED DIAGNOSTIC TECHNIQUES FOR THREE-PHASE SLURRY BUBBLE COLUMN REACTORS(SBCR)

    Energy Technology Data Exchange (ETDEWEB)

    M.H. Al-Dahhan; L.S. Fan; M.P. Dudukovic

    2002-07-25

    This report summarizes the accomplishment made during the third year of this cooperative research effort between Washington University, Ohio State University and Air Products and Chemicals. Data processing of the performed Computer Automated Radioactive Particle Tracking (CARPT) experiments in 6 inch column using air-water-glass beads (150 {micro}m) system has been completed. Experimental investigation of time averaged three phases distribution in air-Therminol LT-glass beads (150 {micro}m) system in 6 inch column has been executed. Data processing and analysis of all the performed Computed Tomography (CT) experiments have been completed, using the newly proposed CT/Overall gas holdup methodology. The hydrodynamics of air-Norpar 15-glass beads (150 {micro}m) have been investigated in 2 inch slurry bubble column using Dynamic Gas Disengagement (DGD), Pressure Drop fluctuations, and Fiber Optic Probe. To improve the design and scale-up of bubble column reactors, a correlation for overall gas holdup has been proposed based on Artificial Neural Network and Dimensional Analysis.

  2. Three-phase double-arc plasma for spectrochemical analysis of environmental samples.

    Science.gov (United States)

    Mohamed, M M; Ghatass, Z F; Shalaby, E A; Kotb, M M; El-Raey, M

    2000-12-01

    A new instrument, which uses a three-phase current to support a double-arc argon plasma torch for evaporation, atomization and excitation of solid or powder samples, is described. The sampling arc is ignited between the first and second electrode while the excitation arc is ignited between the second and third electrode. Aerosol generated from the sample (first electrode) is swept by argon gas, through a hole in the second electrode (carbon tubing electrode), into the excitation plasma. A tangential stream of argon gas is introduced through an inlet orifice as a coolant gas for the second electrode. This gas stream forces the excitation arc discharge to rotate reproducibly around the electrode surface. Discharge rotation increases the stability of the excitation plasma. Spectroscopic measurements are made directly in the current-carrying region of the excitation arc. An evaluation of each parameter influencing the device performance was performed. Analytical calibration curves were obtained for Fe, Al, K, and Pb. Finally, the present technique was applied for the analysis of environmental samples. The present method appears to have significant, low cost analytical utility for environmental measurements.

  3. Three phase heat and mass transfer model for unsaturated soil freezing process: Part 1 - model development

    Science.gov (United States)

    Xu, Fei; Zhang, Yaning; Jin, Guangri; Li, Bingxi; Kim, Yong-Song; Xie, Gongnan; Fu, Zhongbin

    2018-04-01

    A three-phase model capable of predicting the heat transfer and moisture migration for soil freezing process was developed based on the Shen-Chen model and the mechanisms of heat and mass transfer in unsaturated soil freezing. The pre-melted film was taken into consideration, and the relationship between film thickness and soil temperature was used to calculate the liquid water fraction in both frozen zone and freezing fringe. The force that causes the moisture migration was calculated by the sum of several interactive forces and the suction in the pre-melted film was regarded as an interactive force between ice and water. Two kinds of resistance were regarded as a kind of body force related to the water films between the ice grains and soil grains, and a block force instead of gravity was introduced to keep balance with gravity before soil freezing. Lattice Boltzmann method was used in the simulation, and the input variables for the simulation included the size of computational domain, obstacle fraction, liquid water fraction, air fraction and soil porosity. The model is capable of predicting the water content distribution along soil depth and variations in water content and temperature during soil freezing process.

  4. Modular Plug’n’Play Control Architectures for Three-phase Inverters in UPS Applications

    DEFF Research Database (Denmark)

    Zhang, Chi; Guerrero, Josep M.; Vasquez, Juan Carlos

    2015-01-01

    In this paper a control strategy for the parallel operation of three-phase inverters in a modular online uninterruptable power supply (UPS) system is proposed. The UPS system is composed of a number for DC/ACs with LC filter connected to the same AC critical bus and an AC/DC that forms the DC bus...... the AC critical bus voltage. Detailed control architecture, regarding individual layer and recovery layer, are presented in this paper. Also an experimental setup was built to validate the proposed control approach under several scenarios-case study........ The proposed control is designated in two layers, individual layer and recovery layer. In individual layer, virtual impedance concept is employed in order to achieve active power sharing while individual reactive power is calculated to modify output voltage phases to achieve reactive power sharing among...... different modules. Recovery layer is mainly responsible for guaranteeing synchronization capability with the utility and voltage recovery. With the proposed control, improved voltage transient performance can be achieved and also DC/AC modules are allowed to be plugged in and out flexibly while controlling...

  5. Biocatalytic methanation of hydrogen and carbon dioxide in an anaerobic three-phase system.

    Science.gov (United States)

    Burkhardt, M; Koschack, T; Busch, G

    2015-02-01

    A new type of anaerobic trickle-bed reactor was used for biocatalytic methanation of hydrogen and carbon dioxide under mesophilic temperatures and ambient pressure in a continuous process. The conversion of gaseous substrates through immobilized hydrogenotrophic methanogenic archaea in a biofilm is a unique feature of this type of reactor. Due to the formation of a three-phase system on the carrier surface and operation as a plug flow reactor without gas recirculation, a complete reaction could be observed. With a methane concentration higher than c(CH4) = 98%, the product gas exhibits a very high quality. A specific methane production of P(CH4) = 1.49 Nm(3)/(m(3)(SV) d) was achieved at a hydraulic loading rate of LR(H2) = 6.0 Nm(3)/(m(3)(SV) d). The relation between trickle flow through the reactor and productivity could be shown. An application for methane enrichment in combination with biogas facilities as a source of carbon dioxide has also been positively proven. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Three-Phase PV CHB Inverter for a Distributed Power Generation System

    Directory of Open Access Journals (Sweden)

    Pierluigi Guerriero

    2016-10-01

    Full Text Available This work deals with the design of a three-phase grid-tied photovoltaic (PV cascade H-bridge inverter for distributed power conversion. The power balancing among the phases must be properly addressed. In fact, an intra-phase power imbalance—arising from uneven irradiance and temperature conditions—generates a per-phase power imbalance. This latter can be compensated by the injection of a proper zero-sequence voltage, while the intra-phase balance is ensured by means of a hybrid modulation method which is able to guarantee the handling of unequal DC (Direct Current sources, stable circuit operation, and maximization of PV power production. The digital controller is developed and tested in Matlab/Simulink environment integrated with XSG (Xilinx System Generator, thus allowing an easy transfer on a field-programmable gate array (FPGA platform and accurately describing the behavior of a real hardware implementation. Thus, numerical results have been considered to prove the effectiveness of the proposed approach.

  7. A multidisciplinary three-phase approach to improve the clinical utility of patient safety indicators.

    Science.gov (United States)

    Najjar, Peter; Kachalia, Allen; Sutherland, Tori; Beloff, Jennifer; David-Kasdan, Jo Ann; Bates, David W; Urman, Richard D

    2015-01-01

    The AHRQ Patient Safety Indicators (PSIs) are used for calculation of risk-adjusted postoperative rates for adverse events. The payers and quality consortiums are increasingly requiring public reporting of hospital performance on these metrics. We discuss processes designed to improve the accuracy and clinical utility of PSI reporting in practice. The study was conducted at a 793-bed tertiary care academic medical center where PSI processes have been aggressively implemented to track patient safety events at discharge. A three-phased approach to improving administrative data quality was implemented. The initiative consisted of clinical review of all PSIs, documentation improvement, and provider outreach including active querying for patient safety events. This multidisciplinary effort to develop a streamlined process for PSI calculation reduced the reporting of miscoded PSIs and increased the clinical utility of PSI monitoring. Over 4 quarters, 4 of 41 (10%) PSI-11 and 9 of 138 (7%) PSI-15 errors were identified on review of clinical documentation and appropriate adjustments were made. A multidisciplinary, phased approach leveraging existing billing infrastructure for robust metric coding, ongoing clinical review, and frontline provider outreach is a novel and effective way to reduce the reporting of false-positive outcomes and improve the clinical utility of PSIs.

  8. From Two-Phase to Three-Phase: The New Electrochemical Interface by Oxide Electrocatalysts

    Science.gov (United States)

    Xu, Zhichuan J.

    2018-03-01

    Electrochemical reactions typically occur at the interface between a solid electrode and a liquid electrolyte. The charge exchange behaviour between these two phases determines the kinetics of electrochemical reactions. In the past few years, significant advances have been made in the development of metal oxide electrocatalysts for fuel cell and electrolyser reactions. However, considerable gaps remain in the fundamental understanding of the charge transfer pathways and the interaction between the metal oxides and the conducting substrate on which they are located. In particular, the electrochemical interfaces of metal oxides are significantly different from the traditional (metal) ones, where only a conductive solid electrode and a liquid electrolyte are considered. Oxides are insulating and have to be combined with carbon as a conductive mediator. This electrode configuration results in a three-phase electrochemical interface, consisting of the insulating oxide, the conductive carbon, and the liquid electrolyte. To date, the mechanistic insights into this kind of non-traditional electrochemical interface remain unclear. Consequently conventional electrochemistry concepts, established on classical electrode materials and their two-phase interfaces, are facing challenges when employed for explaining these new electrode materials. [Figure not available: see fulltext.

  9. Phenolic Wastewater Treatment using Activated Carbon in a Three Phase Fluidized-Bed Reactor

    Directory of Open Access Journals (Sweden)

    Pornsiri Tongprem

    2009-11-01

    Full Text Available Phenolic wastewater treatment was investigated using activated carbon in a lab scale three phase fluidized-bed reactor. The reactor with effective volume of 272 ml, 300 mm in height and 40 mm in diameter was made from transparent acrylic that allowed to observe the phenomena occurring inside. Phenol 10 mg/l and air were used as representative agents that were continuously fed to the reactor at a constant flow rate of 1 and 2 l/min with co-current and up-flow, respectively. Comparison of the phenolic adsorption under five different conditions: (a fresh Acs, (b 1st reused Acs, (c fresh Fe/Acs, (d 1st reused Fe/Acs, and (e 2nd reused Fe/Acs, have been carried out. The phenolic wastewater was re-circulated through the reactor and its concentration was measured with respect to time. The experimental adsorption results revealed that both fresh Acs and Fe/Acs gave the better results than reused Acs and reused Fe/Acs, respectively. The adsorption in all cases of Acs and Fe/Acs would follow Pseudo-second order kinetic.

  10. An alternative approach in operator allocation labor intensive manufacturing system: A three-phase methodology framework

    Science.gov (United States)

    Mat Rani, Ruzanita; Ismail, Wan Rosmanira

    2013-04-01

    Operator allocation is one of the most important decisions that can affect productivity in labor-intensive manufacturing system. Improper decision on operator allocation will reduce company's throughput and increase waste. Therefore, all factors such as operators' performance and operational constraints need to be considered in making the best operator allocation decision. Most of previous studies used two phases methodology. In two phases methodology, they used operational constraints and treated all operators to have the same level of performance for making decision on operator allocation. Therefore, in this paper a three-phase methodology is proposed to determine the optimal operator allocation. This methodology advances the existing approach on operator allocation by combining operators' performance and operational constraints. The methodology starts with evaluating the operators' performance. Then, it is followed with determining inputs and outputs for operator allocation alternatives and it ends with determining the optimal operator allocation. This paper will give ideas and directions to the management of the manufacturing company in determining the optimal operator allocation decision.

  11. Droplets and the three-phase contact line at the nano-scale. Statics and dynamics

    Science.gov (United States)

    Yatsyshin, Petr; Sibley, David; Savva, Nikos; Kalliadasis, Serafim

    2014-11-01

    Understanding the behaviour of the solid-liquid-vapour contact line at the scale of several tens of molecular diameters is important in wetting hydrodynamics with applications in micro- and nano-fluidics, including the design of lab-on-a-chip devices and surfaces with specific wetting properties. Due to the fluid inhomogeneity at the nano-scale, the application of continuum-mechanical approaches is limited, and a natural way to remedy this is to seek descriptions accounting for the non-local molecular-level interactions. Density Functional Theory (DFT) for fluids offers a statistical-mechanical framework based on expressing the free energy of the fluid-solid pair as a functional of the spatially varying fluid density. DFT allows us to investigate small drops deposited on planar substrates whilst keeping track of the microscopic structural details of the fluid. Starting from a model of intermolecular forces, we systematically obtain interfaces, surface tensions, and the microscopic contact angle. Using a dynamic extension of equilibrium DFT, we investigate the diffusion-driven evolution of the three-phase contact line to gain insight into the dynamic behaviour of the microscopic contact angle, which is still under debate.

  12. Vibration mode and vibration shape under excitation of a three phase model transformer core

    Science.gov (United States)

    Okabe, Seiji; Ishigaki, Yusuke; Omura, Takeshi

    2018-04-01

    Structural vibration characteristics and vibration shapes under three-phase excitation of a archetype transformer core were investigated to consider their influences on transformer noise. Acoustic noise and vibration behavior were measured in a three-limb model transformer core. Experimental modal analysis by impact test was performed. The vibration shapes were measured by a laser scanning vibrometer at different exciting frequencies. Vibration amplitude of the core in out-of-plane direction were relatively larger than those in other two in-plane directions. It was consistent with the result that the frequency response function of the core in out-of-plane direction was larger by about 20 dB or more than those in in-plane directions. There were many vibration modes having bending deformation of limbs in out-of-plane direction. The vibration shapes of the core when excited at 50 Hz and 60 Hz were almost the same because the fundamental frequencies of the vibration were not close to the resonance frequencies. When excitation frequency was 69 Hz which was half of one of the resonance frequencies, the vibration shape changed to the one similar to the resonance vibration mode. Existence of many vibration modes in out-of-plane direction of the core was presumed to be a reason why frequency characteristics of magnetostriction and transformer noise do not coincide.

  13. Advances on the time differential three-phase-lag heat conduction model and major open issues

    Science.gov (United States)

    D'Apice, Ciro; Zampoli, Vittorio

    2017-07-01

    The main purpose of this short contribution is to summarize the recent achievements concerning the so-called time differential three-phase-lag heat conduction model, contextually focusing attention on some of the numerous open problems associated with such an attractive theory. After having briefly recalled the origin of the model at issue, the restrictions upon the delay times and the constitutive tensors able to make it thermodynamically consistent are recalled. Under these hypotheses, the investigation of the well-posedness issue has already provided important results in terms of uniqueness and continuous dependence of the solutions (even related to the thermoelastic case), as well as in terms of existence of a domain of influence of the assigned data in connection with the thermoelastic model. Finally, some of the main problems currently object of investigation are recalled, including the very challenging issues about the different possible choices of Taylor series expansion orders for the constitutive equation, the interaction of the model with energy processes that take place on the nanoscale, with multi-porous materials and with biological systems.

  14. Analysis of dc-Link Voltage Switching Ripple in Three-Phase PWM Inverters

    Directory of Open Access Journals (Sweden)

    Marija Vujacic

    2018-02-01

    Full Text Available The three-phase voltage source inverter (VSI is de facto standard in power conversion systems. To realize high power density systems, one of the items to be correctly addressed is the design and selection of the dc-link capacitor in relation to the voltage switching ripple. In this paper, effective formulas for designing the dc-link capacitor as a function of the switching voltage ripple amplitude are obtained, considering the operating conditions such as the modulation index and the output current amplitude. The calculations are obtained considering the requirements and restrictions referring to the high (switching-frequency dc-link voltage ripple component. Analyses have been performed considering the dc source impedance (non-ideal dc voltage source at the switching frequency and a balanced load. Analytical expressions are derived for the dc-link voltage switching ripple amplitude and its maximum value over the fundamental period. Different values of modulation index and output phase angle have been considered and different diagrams are presented. Analytical results were validated both by simulations and comprehensive experimental tests.

  15. A Smart Voltage and Current Monitoring System for Three Phase Inverters Using an Android Smartphone Application.

    Science.gov (United States)

    Mnati, Mohannad Jabbar; Van den Bossche, Alex; Chisab, Raad Farhood

    2017-04-15

    In this paper, a new smart voltage and current monitoring system (SVCMS) technique is proposed. It monitors a three phase electrical system using an Arduino platform as a microcontroller to read the voltage and current from sensors and then wirelessly send the measured data to monitor the results using a new Android application. The integrated SVCMS design uses an Arduino Nano V3.0 as the microcontroller to measure the results from three voltage and three current sensors and then send this data, after calculation, to the Android smartphone device of an end user using Bluetooth HC-05. The Arduino Nano V3.0 controller and Bluetooth HC-05 are a cheap microcontroller and wireless device, respectively. The new Android smartphone application that monitors the voltage and current measurements uses the open source MIT App Inventor 2 software. It allows for monitoring some elementary fundamental voltage power quality properties. An effort has been made to investigate what is possible using available off-the-shelf components and open source software.

  16. Three-Phase Carbon Fiber Amine Functionalized Carbon Nanotubes Epoxy Composite: Processing, Characterisation, and Multiscale Modeling

    Directory of Open Access Journals (Sweden)

    Kamal Sharma

    2014-01-01

    Full Text Available The present paper discusses the key issues of carbon nanotube (CNT dispersion and effect of functionalisation on the mechanical properties of multiscale carbon epoxy composites. In this study, CNTs were added in epoxy matrix and further reinforced with carbon fibres. Predetermined amounts of optimally amine functionalised CNTs were dispersed in epoxy matrix, and unidirectional carbon fiber laminates were produced. The effect of the presence of CNTs (1.0 wt% in the resin was reflected by pronounced increase in Young’s modulus, inter-laminar shear strength, and flexural modulus by 51.46%, 39.62%, and 38.04%, respectively. However, 1.5 wt% CNT loading in epoxy resin decreased the overall properties of the three-phase composites. A combination of Halpin-Tsai equations and micromechanics modeling approach was also used to evaluate the mechanical properties of multiscale composites and the differences between the predicted and experimental values are reported. These multiscale composites are likely to be used for potential missile and aerospace structural applications.

  17. Indium-111-chloride and three-phase bone scintigraphy: A comparison for imaging experimental osteomyelitis

    International Nuclear Information System (INIS)

    Hoskinson, J.J.; Daniel, G.B.; Patton, C.S.

    1991-01-01

    To investigate the utility of indium-111-chloride ( 111 In-Cl) imaging in detecting osteomyelitis complicating surgical or fracture sites, the proximal tibia of 11 dogs were experimentally infected with Staphylococcus aureus after creation of a cortical defect. The contralateral limb served as a sham-operated control. Animals were serially imaged by radiography, three-phase technetium-99m-methylene diphosphonate (99mTc-MDP) scintigraphy, and 111 In-Cl scintigraphy. There was a significant difference between infected (1.93) and noninfected (1.32) limb's tibia/femur count density ratios on 24-hr (p = 0.0001) and 72-hr (p = 0.0001) 111 In-Cl images. A smaller difference was found for 99mTc-MDP bone-phase tibia/femur ratios (p = 0.0199). Using receiver operator characteristic analysis of tibia/femur ratios, a sensitivity of 61%, specificity of 88%, and positive (75%) and negative (79%) predictive values were determined for the 24-hr 111 In-Cl images. Indium-111-chloride was superior to 99mTc-MDP in differentiating infected and noninfected operative sites

  18. Discovery of fossil lamprey larva from the Lower Cretaceous reveals its three-phased life cycle.

    Science.gov (United States)

    Chang, Mee-mann; Wu, Feixiang; Miao, Desui; Zhang, Jiangyong

    2014-10-28

    Lampreys are one of the two surviving jawless vertebrate groups and one of a few vertebrate groups with the best exemplified metamorphosis during their life cycle, which consists of a long-lasting larval stage, a peculiar metamorphosis, and a relatively short adulthood with a markedly different anatomy. Although the fossil records have revealed that many general features of extant lamprey adults were already formed by the Late Devonian (ca. 360 Ma), little is known about the life cycle of the fossil lampreys because of the lack of fossilized lamprey larvae or transformers. Here we report the first to our knowledge discovery of exceptionally preserved premetamorphic and metamorphosing larvae of the fossil lamprey Mesomyzon mengae from the Lower Cretaceous of Inner Mongolia, China. These fossil ammocoetes look surprisingly modern in having an eel-like body with tiny eyes, oral hood and lower lip, anteriorly positioned branchial region, and a continuous dorsal skin fin fold and in sharing a similar feeding habit, as judged from the detritus left in the gut. In contrast, the larger metamorphosing individuals have slightly enlarged eyes relative to large otic capsules, thickened oral hood or pointed snout, and discernable radials but still anteriorly extended branchial area and lack a suctorial oral disk, which characterize the early stages of the metamorphosis of extant lampreys. Our discovery not only documents the larval conditions of fossil lampreys but also indicates the three-phased life cycle in lampreys emerged essentially in their present mode no later than the Early Cretaceous.

  19. Modeling of a three-phase reactor for bitumen-derived gas oil hydrotreating

    Energy Technology Data Exchange (ETDEWEB)

    Chacon, R.; Canale, A.; Bouza, A. [Departamento de Termodinamica y Fenomenos de Transporte. Universidad Simon Bolivar, Caracas (Venezuela, Bolivarian Republic of); Sanchez, Y. [Departamento de Procesos y Sistemas. Universidad Simon Bolivar (Venezuela, Bolivarian Republic of)

    2012-01-15

    A three-phase reactor model for describing the hydrotreating reactions of bitumen-derived gas oil was developed. The model incorporates the mass-transfer resistance at the gas-liquid and liquid-solid interfaces and a kinetic rate expression based on a Langmuir-Hinshelwood-type model. We derived three correlations for determining the solubility of hydrogen (H{sub 2}), hydrogen sulfide (H{sub 2}S) and ammonia (NH{sub 3}) in hydrocarbon mixtures and the calculation of the catalyst effectiveness factor was included. Experimental data taken from the literature were used to determine the kinetic parameters (stoichiometric coefficients, reaction orders, reaction rate and adsorption constants for hydrodesulfuration (HDS) and hydrodenitrogenation (HDN)) and to validate the model under various operating conditions. Finally, we studied the effect of operating conditions such as pressure, temperature, LHSV, H{sub 2}/feed ratio and the inhibiting effect of H{sub 2}S on HDS and NH{sub 3} on HDN. (author)

  20. Traffic breakdown at a signal: classical theory versus the three-phase theory of city traffic

    International Nuclear Information System (INIS)

    Kerner, Boris S; Schreckenberg, Michael; Klenov, Sergey L

    2014-01-01

    Physical reasons for a crucial difference between the results of a three-phase theory developed recently (Kerner 2011 Phys. Rev. E 84 045102(R); 2013 Europhys. Lett. 102 28010; 2014 Physica A 397 76) and the classical theory are explained. Microscopic characteristics of traffic passing a traffic signal during the green signal phase and their dependence on the duration of the green phase have been found. It turns out that a moving synchronized flow pattern (MSP), which occurs in under-saturated traffic at the signal, causes ‘compression’ of traffic flow: the rate of MSP discharge can be considerably larger than the saturation flow rate of the classical traffic theory of city traffic. This leads to a considerably larger rate of traffic passing the signal in comparison with the saturation flow rate. This effect together with traffic behavior at the upstream queue front explains the metastability of under-saturated traffic with respect to a random time-delayed traffic breakdown. (paper)

  1. Electrochemistry of immobilized particles and droplets experiments with three-phase electrodes

    CERN Document Server

    Scholz, Fritz; Gulaboski, Rubin; Schröder, Uwe

    2014-01-01

    This second edition of a successful and highly-accessed monograph has been extended by more than 100 pages. It includes an enlarged coverage of applications for materials characterization and analysis. Also a more detailed description of strategies for determining free energies of ion transfer between miscible liquids is provided. This is now possible with a "third-phase strategy" which the authors explain from theoretical and practical points of view. The book is still the only one detailing strategies for solid state electroanalysis. It also features the specific potential of the techniques to use immobilized particles (for studies of solid materials) and of immobilized droplets of immiscible liquids for the purpose of studying the three-phase electrochemistry of these liquids. This also includes studies of ion transfer between aqueous and immiscible non-aqueous liquids. The bibliography of all published papers in this field of research has been expanded from 318 to now 444 references in this second editi...

  2. Electric current - frequency converter

    International Nuclear Information System (INIS)

    Kumahara, Tadashi; Kinbana, Setsuro.

    1967-01-01

    Herein disclosed is an improved simple electric current-frequency converter, the input current and output frequency linearity of which is widened to a range of four to five figures while compensating, for temperature. The converter may be used for computor processing and for telemetering the output signals from a nuclear reactor. The converter is an astable multivibrator which includes charging circuits comprising emitter-voltage compensated NPN transistors, a charged voltage detecting circuit of temperature compensated field effect transistors, and a transistor switching circuit for generating switching pulses independent of temperature. The converter exhibited a 0.7% frequency change within a range of 5 - 45 0 C and less than a 0.1% frequency drift after six hours of operation when the input current was maintained constant. (Yamaguchi, T.)

  3. Improving Power Converter Reliability

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    of a high-power IGBT module during converter operation, which may play a vital role in improving the reliability of the power converters. The measured voltage is used to estimate the module average junction temperature of the high and low-voltage side of a half-bridge IGBT separately in every fundamental......The real-time junction temperature monitoring of a high-power insulated-gate bipolar transistor (IGBT) module is important to increase the overall reliability of power converters for industrial applications. This article proposes a new method to measure the on-state collector?emitter voltage...... is measured in a wind power converter at a low fundamental frequency. To illustrate more, the test method as well as the performance of the measurement circuit are also presented. This measurement is also useful to indicate failure mechanisms such as bond wire lift-off and solder layer degradation...

  4. Thermionic photovoltaic energy converter

    Science.gov (United States)

    Chubb, D. L. (Inventor)

    1985-01-01

    A thermionic photovoltaic energy conversion device comprises a thermionic diode mounted within a hollow tubular photovoltaic converter. The thermionic diode maintains a cesium discharge for producing excited atoms that emit line radiation in the wavelength region of 850 nm to 890 nm. The photovoltaic converter is a silicon or gallium arsenide photovoltaic cell having bandgap energies in this same wavelength region for optimum cell efficiency.

  5. Dynamics of voltage source converter in a grid connected solar photovoltaic system

    DEFF Research Database (Denmark)

    Haribabu, Divyanagalakshmi; Vangari, Adithya; Sakamuri, Jayachandra N.

    2015-01-01

    This paper emphasises the modelling and control of a voltage source converter (VSC) for three phase grid connected PV system. The transfer functions for inner current control and outer DC link voltage control for VSC are derived. The controllers for VSC are designed based on PI and K factor contr...

  6. First direct evidence of a vertebrate three-level trophic chain in the fossil record.

    Science.gov (United States)

    Kriwet, Jürgen; Witzmann, Florian; Klug, Stefanie; Heidtke, Ulrich H J

    2008-01-22

    We describe the first known occurrence of a Permian shark specimen preserving two temnospondyl amphibians in its digestive tract as well as the remains of an acanthodian fish, which was ingested by one of the temnospondyls. This exceptional find provides for the first time direct evidence of a vertebrate three-level food chain in the fossil record with the simultaneous preservation of three trophic levels. Our analysis shows that small-sized Lower Permian xenacanthid sharks of the genus Triodus preyed on larval piscivorous amphibians. The recorded trophic interaction can be explained by the adaptation of certain xenacanthids to fully freshwater environments and the fact that in these same environments, large temnospondyls occupied the niche of modern crocodiles. This unique faunal association has not been documented after the Permian and Triassic. Therefore, this Palaeozoic three-level food chain provides strong and independent support for changes in aquatic trophic chain structures through time.

  7. Diode-pumped quasi-three-level CW Nd:CLNGG and Nd:CNGG lasers.

    Science.gov (United States)

    He, Kunna; Wei, Zhiyi; Li, Dehua; Zhang, Zhiguo; Zhang, Huaijin; Wang, Jiyang; Gao, Chunqing

    2009-10-12

    We have demonstrated what is to our knowledge the first quasi-three-level CW Nd:CLNGG laser with simple linear resonator. When the pump power was 18.2 W, a maximum output power of 1.63 W was obtained at the dual-wavelength of 935 nm and 928 nm. The optical-to-optical conversion efficiency was 9.0% and the slope efficiency was 11.5%. Lasing characteristics of a quasi-three-level CW Nd:CNGG laser were also investigated. A maximum output power of 1.87 W was obtained at the single-wavelength of 935 nm with 15.2 W pump power, corresponding to an optical-to-optical conversion efficiency of 12.3% and a slope efficiency of 15.6%.

  8. Testing strong factorial invariance using three-level structural equation modeling

    Directory of Open Access Journals (Sweden)

    Suzanne eJak

    2014-07-01

    Full Text Available Within structural equation modeling, the most prevalent model to investigate measurement bias is the multigroup model. Equal factor loadings and intercepts across groups in a multigroup model represent strong factorial invariance (absence of measurement bias across groups. Although this approach is possible in principle, it is hardly practical when the number of groups is large or when the group size is relatively small. Jak, Oort and Dolan (2013 showed how strong factorial invariance across large numbers of groups can be tested in a multilevel structural equation modeling framework, by treating group as a random instead of a fixed variable. In the present study, this model is extended for use with three-level data. The proposed method is illustrated with an investigation of strong factorial invariance across 156 school classes and 50 schools in a Dutch dyscalculia test, using three-level structural equation modeling.

  9. An efficiency improved single-phase PFC converter for electric vehicle charger applications

    DEFF Research Database (Denmark)

    Zhu, Dexuan; Tang, Yi; Jin, Chi

    2013-01-01

    This paper presents an efficiency improved single-phase power factor correction (PFC) converter with its target application to plug-in hybrid electric vehicle (PHEV) charging systems. The proposed PFC converter features sinusoidal input current, three-level output characteristic, and wide range...

  10. Cross-Regulation Assessment of DIDO Buck-Boost Converter for Renewable Energy Application

    Directory of Open Access Journals (Sweden)

    Deepak Elamalayil Soman

    2017-06-01

    Full Text Available When medium- or high-voltage power conversion is preferred for renewable energy sources, multilevel power converters have received much of the interest in this area as methods for enhancing the conversion efficiency and cost effectiveness. In such cases, multilevel, multi-input multi-output (MIMO configurations of DC-DC converters come to the scenario for integrating several sources together, especially considering the stringent regulatory needs and the requirement of multistage power conversion systems. Considering the above facts, a three-level dual input dual output (DIDO buck-boost converter, as the simplest form of MIMO converter, is proposed in this paper for DC-link voltage regulation. The capability of this converter for cross regulating the DC-link voltage is analyzed in detail to support a three-level neutral point clamped inverter-based grid connection in the future. The cross-regulation capability is examined under a new type of pulse delay control (PDC strategy and later compared with a three-level boost converter (TLBC. Compared to conventional boost converters, the high-voltage three-level buck boost converter (TLBBC with PDC exhibits a wide controllability range and cross regulation capability. These enhanced features are extremely important for better regulating variable output renewable energy sources such as solar, wind, wave, marine current, etc. The simulation and experimental results are provided to validate the claim.

  11. Kramers–Kronig relation in a Doppler-broadened Λ-type three-level system

    International Nuclear Information System (INIS)

    Wang Meng; Lu Xiao-Gang; Bai Jin-Hai; Miao Xing-Xu; Gao Yan-Lei; Wu Ling-An; Fu Pan-Ming; Wang Ru-Quan; Zuo Zhan-Chun; Pei Li-Ya; Yang Shi-Ping; Pang Zhao-Guang

    2015-01-01

    We measure the absorption and dispersion in a Doppler-broadened Λ-type three level system by resonant stimulated Raman spectroscopy with homodyne detection. Through studying the dressed state energies of the system, it is found that the absorption and dispersion satisfy the Kramers–Kronig relation. The absorption and dispersion spectra calculated by employing this relation agree well with our experimental observations. (rapid communication)

  12. Three-level models solvable in terms of the Clausen function

    Energy Technology Data Exchange (ETDEWEB)

    Ishkhanyan, Artur [Engineering Center of Armenian National Academy of Sciences, Ashtarak-2, 378410 (Armenia); Suominen, Kalle-Antti [Helsinki Institute of Physics, PL 64, FIN-00014 Helsingin yliopisto (Finland)

    2003-07-04

    The problem of analytical integrability of the three-level problem by reduction of the time-dependent Schroedinger equations to the third-order linear differential equation satisfied by the generalized hypergeometric functions {sub 3}F{sub 2} is considered. A total of 12 infinite classes of models solvable in terms of these functions is found, most of which are new and others are generalizations of the previously known families.

  13. Three-level models solvable in terms of the Clausen function

    International Nuclear Information System (INIS)

    Ishkhanyan, Artur; Suominen, Kalle-Antti

    2003-01-01

    The problem of analytical integrability of the three-level problem by reduction of the time-dependent Schroedinger equations to the third-order linear differential equation satisfied by the generalized hypergeometric functions 3 F 2 is considered. A total of 12 infinite classes of models solvable in terms of these functions is found, most of which are new and others are generalizations of the previously known families

  14. Emission spectrum of a harmonically trapped Λ-type three-level atom

    International Nuclear Information System (INIS)

    Guo Hong; Tang Pei

    2013-01-01

    We theoretically investigate the emission spectrum for a Λ-type three-level atom trapped in the node of a standing wave. We show that the atomic center-of-mass motion not only directly affects the peak number, peak position, and peak height in the atomic emission spectrum, but also influences the effects of the cavity field and the atomic initial state on atomic emission spectrum. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  15. Scheme of 2-dimensional atom localization for a three-level atom via quantum coherence

    OpenAIRE

    Zafar, Sajjad; Ahmed, Rizwan; Khan, M. Khalid

    2013-01-01

    We present a scheme for two-dimensional (2D) atom localization in a three-level atomic system. The scheme is based on quantum coherence via classical standing wave fields between the two excited levels. Our results show that conditional position probability is significantly phase dependent of the applied field and frequency detuning of spontaneously emitted photons. We obtain a single localization peak having probability close to unity by manipulating the control parameters. The effect of ato...

  16. Three Level Diode Clamped Inverter Fed Induction Motor with Dtc-Svm

    OpenAIRE

    V. Ranjith Kumar

    2013-01-01

    This project presents a three-level diode-clamped inverter feeding an asynchronous motor drive with direct torque control (DTC). The control method is based on DTC operating principles. The stator voltage vector reference is computed from the stator flux and torque errors imposed by the flux and torque controllers. This voltage reference is then generated using a diode-clamped inverter, where each phase of the inverter can be implemented using a dc source, which would be available from fuel c...

  17. Inversionless superradiance of an ensemble of three-level atoms in a high-Q cavity

    International Nuclear Information System (INIS)

    Zaitsev, A.I.; Ryzhov, I.V.; Trifonov, E.D.; Malyshev, V.A.

    1999-01-01

    We analyze the possibility of superradiance in an ensemble of three-level atoms in the absence of population inversion. We show that in the case of a Λ configuration of the active transitions this effect can occur for an initially coherent superposition of the states of the lower doublet. We also study how splitting of the lower levels influences this effect and discuss ways of creating low-frequency coherence

  18. Intergenerational transmission of educational attainment: Three levels of parent-child communication as mediators.

    Science.gov (United States)

    Chi, Liping

    2013-04-01

    Although the intergenerational transmission of educational attainment has been confirmed by many researchers, its mechanism still remains controversial. Parent-child communication has been regarded as one of the important mediators. The present study primarily aimed to examine the potentially mediating role of parent-child communication in the transmission of educational attainment, based on a sample of 366 Chinese fifth and sixth graders. Parent-child communication was measured against the three levels of the parents' communication ability, the quality of the father-child and mother-child communications, and the relation between the two dyadic communications. The results duplicated the positive effect of parents' educational attainment on children's academic achievement. Moreover, it was found that parents' communication ability alone played a mediating role, and that the three levels of parent-child communication constructed a "mediator chain" between the parents' educational attainment and the children's academic achievement. Finally, the intergenerational transmission of educational attainment in China and the mediating role of the three levels of parent-child communication were discussed. © 2012 The Institute of Psychology, Chinese Academy of Sciences and Blackwell Publishing Asia Pty Ltd.

  19. Three phase partitioning of zingibain, a milk-clotting enzyme from Zingiber officinale Roscoe rhizomes.

    Science.gov (United States)

    Gagaoua, Mohammed; Hoggas, Naouel; Hafid, Kahina

    2015-02-01

    The present work describes for the first time an elegant non-chromatographic method, the three phase partitioning for the purification and recovery of zingibain, a milk-clotting enzyme, from Zingiber officinale rhizomes. Factors affecting partitioning efficiency such as (NH4)2SO4 saturation, crude extract to t-butanol ratio and pH on zingibain partitioning were investigated. Optimal purification parameters were 50% (NH4)2SO4 saturation with 1.0:1.0 ratio of crude extract:t-butanol at pH 7.0, which gave 14.91 purification fold with 215% recovery of zingibain. The enzyme was found to be exclusively partitioned in the aqueous phase. The enzyme showed a prominent single band on SDS-PAGE. It is a monomeric protein of 33.8 kDa and its isoelectric point is 4.38. The enzyme exhibited maximal proteolytic activity at a temperature of 60 °C and pH 7.0. It was found to be stable at 40-65 °C during 2 h. The enzyme was found to be highly stable against numerous metal ions and its activity was enhanced by Ca(2+), K(+) and Na(+). It was completely inhibited by heavy metal ions such as Cu(2+) and Hg(2+) and partially by Cd(+). Zingibain milk-clotting activity (MCA) was found to be highly stable when stored under freezing (-20 °C) for 30 days compared at 4 °C. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Three-phase Bone Scintigraphy Can Predict the Analgesic Efficacy of Ketamine Therapy in CRPS.

    Science.gov (United States)

    Sorel, Marc; Beatrix, Jacques-Christian; Locko, Blanche; Armessen, Catherine; Domec, Anne-Marie; Lecompte, Otilia; Boucheneb, Sofiane; Harache, Benoit; Robert, Jacques; Lefaucheur, Jean-Pascal

    2018-03-13

    The efficacy of ketamine in relieving complex regional pain syndrome (CRPS) lacks predictive factors. The value of three-phase bone scintigraphy (TPBS) was assessed or this purpose. TPBS was performed in 105 patients with unilateral, focal CRPS of type 1 before 5 days of ketamine infusions. Tracer uptake was measured in the region of interest concerned by CRPS and the contralateral homologous region. For the three scintigraphic phases (vascular, tissular, and bone phases), an asymmetry ratio of fixation was calculated between the affected and the unaffected sides (VPr, TPr, and BPr). Ketamine efficacy was assessed on pain intensity scores. Ketamine-induced pain relief did not correlate with VPr, TPr, and BPr, but with the ratios of these ratios: BPr/TPr (r=0.32, P=0.009), BPr/VPr (r=0.34, P=0.005), and TPr/VPr (r=0.23, P=0.02). The optimum cut-off value for predicting the response to ketamine therapy was >1.125 for BPr/TPr, >1.075 for BPr/VPr, and >0.935 for TPr/VPr. The combination of increased values of BPr/TPr, BPr/VPr, and TPr/VPr was extremely significantly associated with ketamine therapy outcome. The relative hyperfixation of the radioactive tracer in the limb region concerned by CRPS in phases 2 and 3 versus phase 1 of TPBS correlated positively to the analgesic efficacy of ketamine. This study shows for the first time the potential predictive value of TPBS regarding ketamine therapy outcome. In addition, these results suggest that the analgesic action of ketamine is not restricted to "central" mechanisms, but may also involve "peripheral" mechanisms related to tissue inflammation and bone remodeling.

  1. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, D. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Caricasulo, D. [Orthopaedics Dept., General Hospital of Bassano del Grappa (Italy); Borsato, N. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Chierichetti, F. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Zanco, P. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Ferlin, G. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy)

    1996-10-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic {sup 99m}TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  2. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    International Nuclear Information System (INIS)

    Rubello, D.; Caricasulo, D.; Borsato, N.; Chierichetti, F.; Zanco, P.; Ferlin, G.

    1996-01-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic 99m TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  3. COMPUTATIONAL AND EXPERIMENTAL MODELING OF THREE-PHASE SLURRY-BUBBLE COLUMN REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    Isaac K. Gamwo; Dimitri Gidaspow

    1999-09-01

    Considerable progress has been achieved in understanding three-phase reactors from the point of view of kinetic theory. In a paper in press for publication in Chemical Engineering Science (Wu and Gidaspow, 1999) we have obtained a complete numerical solution of bubble column reactors. In view of the complexity of the simulation a better understanding of the processes using simplified analytical solutions is required. Such analytical solutions are presented in the attached paper, Large Scale Oscillations or Gravity Waves in Risers and Bubbling Beds. This paper presents analytical solutions for bubbling frequencies and standing wave flow patterns. The flow patterns in operating slurry bubble column reactors are not optimum. They involve upflow in the center and downflow at the walls. It may be possible to control flow patterns by proper redistribution of heat exchangers in slurry bubble column reactors. We also believe that the catalyst size in operating slurry bubble column reactors is not optimum. To obtain an optimum size we are following up on the observation of George Cody of Exxon who reported a maximum granular temperature (random particle kinetic energy) for a particle size of 90 microns. The attached paper, Turbulence of Particles in a CFB and Slurry Bubble Columns Using Kinetic Theory, supports George Cody's observations. However, our explanation for the existence of the maximum in granular temperature differs from that proposed by George Cody. Further computer simulations and experiments involving measurements of granular temperature are needed to obtain a sound theoretical explanation for the possible existence of an optimum catalyst size.

  4. A self-consistent model of the three-phase interstellar medium in disk galaxies

    International Nuclear Information System (INIS)

    Wang, Z.

    1989-01-01

    In the present study the author analyzes a number of physical processes concerning velocity and spatial distributions, ionization structure, pressure variation, mass and energy balance, and equation of state of the diffuse interstellar gas in a three phase model. He also considers the effects of this model on the formation of molecular clouds and the evolution of disk galaxies. The primary purpose is to incorporate self-consistently the interstellar conditions in a typical late-type galaxy, and to relate these to various observed large-scale phenomena. He models idealized situations both analytically and numerically, and compares the results with observational data of the Milky Way Galaxy and other nearby disk galaxies. Several main conclusions of this study are: (1) the highly ionized gas found in the lower Galactic halo is shown to be consistent with a model in which the gas is photoionized by the diffuse ultraviolet radiation; (2) in a quasi-static and self-regulatory configuration, the photoelectric effects of interstellar grains are primarily responsible for heating the cold (T ≅ 100K) gas; the warm (T ≅ 8,000K) gas may be heated by supernova remnants and other mechanisms; (3) the large-scale atomic and molecular gas distributions in a sample of 15 disk galaxies can be well explained if molecular cloud formation and star formation follow a modified Schmidt Law; a scaling law for the radial gas profiles is proposed based on this model, and it is shown to be applicable to the nearby late-type galaxies where radio mapping data is available; for disk galaxies of earlier type, the effect of their massive central bulges may have to be taken into account

  5. Mixing in three-phase systems: Implications for enhanced oil recovery and unconventional gas extraction

    Science.gov (United States)

    Jimenez-Martinez, J.; Porter, M. L.; Hyman, J.; Carey, J. W.; Viswanathan, H. S.

    2015-12-01

    Although the mixing of fluids within a porous media is a common process in natural and industrial systems, how the degree of mixing depends on the miscibility of multiple phases is poorly characterized. Often, the direct consequence of miscible mixing is the modification of the resident fluid (brine and hydrocarbons) rheological properties. We investigate supercritical (sc)CO2 displacement and mixing processes in a three-phase system (scCO2, oil, and H2O) using a microfluidics experimental system that accommodates the high pressures and temperatures encountered in fossil fuel extraction operations. The miscibility of scCO2 with the resident fluids, low with aqueous solutions and high with hydrocarbons, impacts the mixing processes that control sweep efficiency in enhanced oil recovery (EOR) and the unlocking of the system in unconventional oil and gas extraction. Using standard volume-averaging techniques we upscale the aqueous phase saturation to the field-scale (i.e., Darcy scale) and interpret the results as a simpler two-phase system. This process allows us to perform a statistical analysis to quantify i) the degree of heterogeneity in the system resulting from the immiscible H2O and ii) how that heterogeneity impacts mixing between scCO2 and oil and their displacement. Our results show that when scCO2 is used for miscible displacement, the presence of an aqueous solution, which is common in secondary and tertiary EOR and unconventional oil and gas extraction, strongly impacts the mixing of scCO2 with the hydrocarbons due to low scCO2-H2O miscibility. H2O, which must be displaced advectively by the injected scCO2, introduces spatio-temporal variability into the system that acts as a barrier between the two miscibile fluids. This coupled with the effect of viscosity contrast, i.e., viscous fingering, has an impact on the mixing of the more miscible pair.

  6. Nonlinear adaptive control of grid-connected three-phase inverters for renewable energy applications

    Science.gov (United States)

    Mahdian-Dehkordi, N.; Namvar, M.; Karimi, H.; Piya, P.; Karimi-Ghartemani, M.

    2017-01-01

    Distributed generation (DG) units are often interfaced to the main grid using power electronic converters including voltage-source converters (VSCs). A VSC offers dc/ac power conversion, high controllability, and fast dynamic response. Because of nonlinearities, uncertainties, and system parameters' changes involved in the nature of a grid-connected renewable DG system, conventional linear control methods cannot completely and efficiently address all control objectives. In this paper, a nonlinear adaptive control scheme based on adaptive backstepping strategy is presented to control the operation of a grid-connected renewable DG unit. As compared to the popular vector control technique, the proposed controller offers smoother transient responses, and lower level of current distortions. The Lyapunov approach is used to establish global asymptotic stability of the proposed control system. Linearisation technique is employed to develop guidelines for parameters tuning of the controller. Extensive time-domain digital simulations are performed and presented to verify the performance of the proposed controller when employed in a VSC to control the operation of a two-stage DG unit and also that of a single-stage solar photovoltaic system. Desirable and superior performance of the proposed controller is observed.

  7. An improved design of virtual output impedance loop for droop-controlled parallel three-phase Voltage Source Inverters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2012-01-01

    -sequence virtual resistance even in the case of feeding a balanced three-phase load. Furthermore, to adapt to the variety of unbalanced loads, a dynamically-tuned negative-sequence resistance loop is designed, such that a good compromise between the quality of inverter output voltage and the performance of load......The virtual output impedance loop is known as an effective way to enhance the load sharing stability and quality of droop-controlled parallel inverters. This paper proposes an improved design of virtual output impedance loop for parallel three-phase voltage source inverters. In the approach...... sharing can be obtained. Finally, laboratory test results of two parallel three-phase voltage source inverters are shown to confirm the validity of the proposed method....

  8. Direct Power Control for Three-Phase Two-Level Voltage-Source Rectifiers Based on Extended-State Observation

    DEFF Research Database (Denmark)

    Song, Zhanfeng; Tian, Yanjun; Yan, Zhuo

    2016-01-01

    This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent characte......This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent...

  9. A Three-Level Quasi-Two-Stage Single-Phase PFC Converter with Flexible Output Voltage and Improved Conversion Efficiency

    DEFF Research Database (Denmark)

    Tang, Yi; Zhu, Dexuan; Jin, Chi

    2015-01-01

    voltages, and it will be very suitable for high-power applications where the output voltage can be either lower or higher than the peak ac input voltage, e.g., plug-in hybrid electric vehicle charging systems. Moreover, the involved dc/dc buck conversion stage may only need to process partial input power...

  10. Parallel power electronics filters in three-phase four-wire systems principle, control and design

    CERN Document Server

    Wong, Man-Chung; Lam, Chi-Seng

    2016-01-01

    This book describes parallel power electronic filters for 3-phase 4-wire systems, focusing on the control, design and system operation. It presents the basics of power-electronics techniques applied in power systems as well as the advanced techniques in controlling, implementing and designing parallel power electronics converters. The power-quality compensation has been achieved using active filters and hybrid filters, and circuit models, control principles and operational practice problems have been verified by principle study, simulation and experimental results. The state-of-the-art research findings were mainly developed by a team at the University of Macau. Offering background information and related novel techniques, this book is a valuable resource for electrical engineers and researchers wanting to work on energy saving using power-quality compensators or renewable energy power electronics systems. .

  11. Hybrid Three-Phase/Single-Phase Microgrid Architecture with Power Management Capabilities

    DEFF Research Database (Denmark)

    Sun, Qiuye; Zhou, Jianguo; Guerrero, Josep M.

    2015-01-01

    With the fast proliferation of single-phase distributed generation (DG) units and loads integrated into residential microgrids, independent power sharing per phase and full use of the energy generated by DGs have become crucial. To address these issues, this paper proposes a hybrid microgrid...... architecture and its power management strategy. In this microgrid structure, a power sharing unit (PSU), composed of three single-phase back-to-back (SPBTB) converters, is proposed to be installed at the point of common coupling (PCC). The aim of the PSU is mainly to realize the power exchange and coordinated...... control of load power sharing among phases, as well as to allow fully utilization of the energy generated by DGs. Meanwhile, the method combining the modified adaptive backstepping-sliding mode control approach and droop control is also proposed to design the SPBTB system controllers. With the application...

  12. Simulation of three-phase flow and lance height effect on the cavity shape

    Science.gov (United States)

    Dong, Kai; Zhu, Rong; Gao, Wei; Liu, Fu-hai

    2014-06-01

    A three-dimensional computational fluid dynamics (CFD) model was developed to simulate a 150-t top-blown converter. The effect of different lance heights on the cavity shape was investigated using the volume of fluid (VOF) method. Numerical simulation results can reflect the actual molten bath surface waves impinged by the supersonic oxygen jets. With increasing lance height, the cavity depth decreases, and the cavity area, varying like a parabola, increases and then decreases. The cavity area maximizes at the lance height of 1.3 m. Under the three different lance heights simulated in this study, all of the largest impact velocities at the molten bath surface are between 50 m/s and 100 m/s.

  13. Spectral induced polarization of the three-phase system CO2 - brine - sand under reservoir conditions

    Science.gov (United States)

    Börner, Jana H.; Herdegen, Volker; Repke, Jens-Uwe; Spitzer, Klaus

    2017-01-01

    The spectral complex conductivity of a water-bearing sand during interaction with carbon dioxide (CO2) is influenced by multiple, simultaneous processes. These processes include partial saturation due to the replacement of conductive pore water with CO2 and chemical interaction of the reactive CO2 with the bulk fluid and the grain-water interface. We present a laboratory study on the spectral induced polarization of water-bearing sands during exposure to and flow-through by CO2. Conductivity spectra were measured successfully at pressures up to 30 MPa and 80 °C during active flow and at steady-state conditions concentrating on the frequency range between 0.0014 and 100 Hz. The frequency range between 0.1 and 100 Hz turned out to be most indicative for potential monitoring applications. The presented data show that the impact of CO2 on the electrolytic conductivity may be covered by a model for pore-water conductivity, which depends on salinity, pressure and temperature and has been derived from earlier investigations of the pore-water phase. The new data covering the three-phase system CO2-brine-sand further show that chemical interaction causes a reduction of surface conductivity by almost 20 per cent, which could be related to the low pH-value in the acidic environment due to CO2 dissolution and the dissociation of carbonic acid. The quantification of the total CO2 effect may be used as a correction during monitoring of a sequestration in terms of saturation. We show that this leads to a correct reconstruction of fluid saturation from electrical measurements. In addition, an indicator for changes of the inner surface area, which is related to mineral dissolution or precipitation processes, can be computed from the imaginary part of conductivity. The low frequency range between 0.0014 and 0.1 Hz shows additional characteristics, which deviate from the behaviour at higher frequencies. A Debye decomposition approach is applied to isolate the feature dominating the

  14. Dielectric and piezoelectric properties of percolative three-phase piezoelectric polymer composites

    Science.gov (United States)

    Sundar, Udhay

    Three-phase piezoelectric bulk composites were fabricated using a mix and cast method. The composites were comprised of lead zirconate titanate (PZT), aluminum (Al) and an epoxy matrix. The volume fraction of the PZT and Al were varied from 0.1 to 0.3 and 0.0 to 0.17, respectively. The influences of three entities on piezoelectric and dielectric properties: inclusion of an electrically conductive filler (Al), poling process (contact and Corona) and Al surface treatment, were observed. The piezoelectric strain coefficient, d33, effective dielectric constant, epsilon r, capacitance, C, and resistivity were measured and compared according to poling process, volume fraction of constituent phases and Al surface treatment. The maximum values of d33 were 3.475 and 1.0 pC/N for Corona and contact poled samples respectively, for samples with volume fractions of 0.40 and 0.13 of PZT and Al (surface treated) respectively. Also, the maximum dielectric constant for the surface treated Al samples was 411 for volume fractions of 0.40 and 0.13 for PZT and Al respectively. The percolation threshold was observed to occur at an Al volume fraction of 0.13. The composites achieved a percolated state for Al volume fractions >0.13 for both contact and corona poled samples. In addition, a comparative time study was conducted to examine the influence of surface treatment processing time of Al particles. The effectiveness of the surface treatment, sample morphology and composition was observed with the aid of SEM and EDS images. These images were correlated with piezoelectric and dielectric properties. PZT-epoxy-aluminum thick films (200 mum) were also fabricated using a two-step spin coat deposition and annealing method. The PZT volume fraction were varied from 0.2, 0.3 and 0.4, wherein the Aluminum volume fraction was varied from 0.1 to 0.17 for each PZT volume fraction, respectively. The two-step process included spin coating the first layer at 500 RPM for 30 seconds, and the second

  15. Effects of NOx-inhibitor agent on fuel properties of three-phase biodiesel emulsions

    International Nuclear Information System (INIS)

    Lin, Cherng-Yuan; Lin, Hsiu-An

    2008-01-01

    Biodiesel is one of the more promising alternative clean fuels to fossil fuel, which can reduce the emissions of fossil fuel burning, and possibly resolve the energy crisis caused by the exhaustion of petroleum resources in the near future. The burning of biodiesel emits much less gaseous emissions and particulate matter primarily because of its dominant combustion efficiency. However, the high oxygen content in biodiesel not only promotes the burning process but also enhances NO x formation when biodiesel is used as fuel. Biodiesel emulsion and the additive of NO x -inhibitor agent are considered to reduce levels of NO x emissions in this experimental study. The biodiesel was produced by transesterification reaction accompanied with peroxidation process. A three-phase biodiesel emulsion of oil-in water drops-in oil (O/W/O) and an O/W/O biodiesel emulsion containing aqueous ammonia were prepared afterwards. The effect of the existence of NO x -inhibitor agent on the fuel properties and the emulsion characteristics of the O/W/O biodiesel emulsions were investigated. The experimental results show that the burning of the O/W/O biodiesel emulsion and the O/W/O biodiesel emulsion containing aqueous ammonia had larger fraction of fuel burnt and thus larger heat release than the neat biodiesel if water content is not considered for the calculation of heating value. The addition of aqueous ammonia within the dispersed phase of the O/W/O biodiesel emulsion appeared to deteriorate the emulsification characteristics. A smaller quantity of emulsion and greater kinematic viscosity were formed while a larger carbon residue and actual reaction-heat release also appeared for this O/W/O biodiesel emulsion. Aqueous ammonia in the O/W/O biodiesel emulsion produces a higher pH value as well. In addition, the number as well as the volumetric fraction of the dispersed water droplets is reduced for the O/W/O biodiesel emulsion that contains aqueous ammonia. (author)

  16. Optimal control of population and coherence in three-level Λ systems

    Science.gov (United States)

    Kumar, Praveen; Malinovskaya, Svetlana A.; Malinovsky, Vladimir S.

    2011-08-01

    Optimal control theory (OCT) implementations for an efficient population transfer and creation of maximum coherence in a three-level system are considered. We demonstrate that the half-stimulated Raman adiabatic passage scheme for creation of the maximum Raman coherence is the optimal solution according to the OCT. We also present a comparative study of several implementations of OCT applied to the complete population transfer and creation of the maximum coherence. Performance of the conjugate gradient method, the Zhu-Rabitz method and the Krotov method has been analysed.

  17. Optical Resonance of A Three-Level System in Semiconductor Quantum Dots

    Directory of Open Access Journals (Sweden)

    Nguyen Van Hieu

    2017-11-01

    Full Text Available The optical resonance of a three-level system of the strongly correlated electrons in the twolevel semiconductor quantum dot interacting with the linearly polarized monochromatic electromagnetic radiation is studied. With the application of the Green function method the expressions of the state vectors and the energies of the stationary states of the system in the regime of the optical resonance are derived. The Rabi oscillations of the electron populations at different levels as well as the Rabi splitting of the peaks in the photon emission spectra are investigated. PACS numbers: 71.35.-y, 78.55.-m, 78.67.Hc

  18. Light propagation from subluminal to superluminal in a three-level Λ-type system

    International Nuclear Information System (INIS)

    Sun Hui; Guo Hong; Bai, Yanfeng; Han Dingan; Fan Shuangli; Chen Xuzong

    2005-01-01

    We show that the group velocity of a weak electromagnetic pulse can be manipulated by adjusting the relative phase of the probing and the pumping fields applied to a Λ-type three-level system, whose two lower states are coupled by an external control magnetic field. Such control field can, in principle, cause the light propagation to be changed from subluminal to superluminal by modulating the relative phase. The same effect can be obtained by varying the intensities of the pumping and the control magnetic fields, but it is different with Agarwal's [Phys. Rev. A 64 (2001) 053809]. The effect of Doppler broadening on the dispersion is also investigated

  19. Three-Level Z-Source Inverters Using a Single LC Impedance Network

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Lim, Sok Wei; Gao, Feng

    2007-01-01

    two LC impedance networks and two isolated dc sources, which can significantly increase the overall system cost and require a more complex modulator for balancing the network inductive voltage boosting. Offering a number of less costly alternatives, this letter presents the design and control of two...... three-level Z-source inverters, whose output voltage can be stepped down or up using only a single LC impedance network connected between the dc input source and either a neutral-point-clamped (NPC) or dc-link cascaded inverter circuitry. Through careful design of their modulation scheme, both inverters...

  20. Realization of a holonomic quantum computer in a chain of three-level systems

    Energy Technology Data Exchange (ETDEWEB)

    Gürkan, Zeynep Nilhan, E-mail: nilhan.gurkan@gediz.edu.tr [Department of Industrial Engineering, Gediz University, Seyrek, 35665 Menemen, Izmir (Turkey); Centre for Quantum Technologies, National University of Singapore, 3 Science Drive 2, 117543 Singapore (Singapore); Sjöqvist, Erik, E-mail: erik.sjoqvist@kemi.uu.se [Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Department of Quantum Chemistry, Uppsala University, Box 518, SE-751 20 Uppsala (Sweden)

    2015-12-18

    Holonomic quantum computation is the idea to use non-Abelian geometric phases to implement universal quantum gates that are robust to fluctuations in control parameters. Here, we propose a compact design for a holonomic quantum computer based on coupled three-level systems. The scheme does not require adiabatic evolution and can be implemented in arrays of atoms or ions trapped in tailored standing wave potentials. - Highlights: • We develop a novel scheme for universal holonomic quantum computation. • The scheme involves non-Abelian geometric phases in a spin-chain. • The resources scale linearly with the number of logical qubits. • The scheme does not require adiabatic evolution.

  1. Constraints on dephasing widths and shifts in three-level quantum systems

    International Nuclear Information System (INIS)

    Berman, P.R.; O'Connell, Ross C.

    2005-01-01

    It is shown that the density matrix equations for a three-level quantum system interacting with external radiation fields can lead to negative populations if arbitrary dephasing rates and shifts are included in these equations. To guarantee non-negative populations, the equations themselves impose certain restrictions on the dephasing widths and shifts. The constraints on the widths are shown to be identical to those that can be derived from a model of Markovian dephasing events, independent of any atom-field interaction

  2. Realization of a holonomic quantum computer in a chain of three-level systems

    International Nuclear Information System (INIS)

    Gürkan, Zeynep Nilhan; Sjöqvist, Erik

    2015-01-01

    Holonomic quantum computation is the idea to use non-Abelian geometric phases to implement universal quantum gates that are robust to fluctuations in control parameters. Here, we propose a compact design for a holonomic quantum computer based on coupled three-level systems. The scheme does not require adiabatic evolution and can be implemented in arrays of atoms or ions trapped in tailored standing wave potentials. - Highlights: • We develop a novel scheme for universal holonomic quantum computation. • The scheme involves non-Abelian geometric phases in a spin-chain. • The resources scale linearly with the number of logical qubits. • The scheme does not require adiabatic evolution.

  3. Tunneling and traversal of ultracold three-level atoms through vacuum-induced potentials

    Energy Technology Data Exchange (ETDEWEB)

    Badshah, Fazal; Irfan, Muhammad; Qamar, Shahid [Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650 (Pakistan); Qamar, Sajid [Department of Physics, COMSATS Institute of Information Technology, Islamabad (Pakistan)

    2011-09-15

    The passage of ultracold three-level atoms through the potential induced by the vacuum cavity mode is discussed using cascade atomic configuration. We study the tunneling or traversal time of the ultracold atoms via a bimodal high-Q cavity. It is found that the phase time, which may be considered as a measure for the time required to traverse the cavity, exhibits superclassical and subclassical behaviors. Further, the dark states and interference effects in cascade atomic configuration may influence the passage time of the atom through the cavity.

  4. Tunneling and traversal of ultracold three-level atoms through vacuum-induced potentials

    International Nuclear Information System (INIS)

    Badshah, Fazal; Irfan, Muhammad; Qamar, Shahid; Qamar, Sajid

    2011-01-01

    The passage of ultracold three-level atoms through the potential induced by the vacuum cavity mode is discussed using cascade atomic configuration. We study the tunneling or traversal time of the ultracold atoms via a bimodal high-Q cavity. It is found that the phase time, which may be considered as a measure for the time required to traverse the cavity, exhibits superclassical and subclassical behaviors. Further, the dark states and interference effects in cascade atomic configuration may influence the passage time of the atom through the cavity.

  5. The effect of a coupling field on the entanglement dynamics of a three-level atom

    International Nuclear Information System (INIS)

    Mortezapour, Ali; Mahmoudi, Mohammad; Abedi, Majid; Khajehpour, M R H

    2011-01-01

    The effect of a coupling laser field on the entanglement of a three-level quantum system and its spontaneous emission is investigated via the reduced quantum entropy. We consider two schemes: the upper- and lower-level couplings. By calculating the degree of entanglement (DEM) for both systems, it is shown that the entanglement between the atom and its spontaneous emission can be controlled by the coupling laser field. This field, however, affects the entanglement differently in the two schemes; it is only the lower-level coupling scheme that shows a non-zero steady state DEM which can be controlled by the intensity and detuning of the coupling laser field.

  6. The effect of a coupling field on the entanglement dynamics of a three-level atom

    Energy Technology Data Exchange (ETDEWEB)

    Mortezapour, Ali; Mahmoudi, Mohammad [Physics Department, Zanjan University, PO Box 45195-313, Zanjan (Iran, Islamic Republic of); Abedi, Majid; Khajehpour, M R H, E-mail: mahmoudi@iasbs.ac.ir, E-mail: pour@iasbs.ac.ir [Institute for Advanced Studies in Basic Sciences, PO Box 45195-159, Zanjan (Iran, Islamic Republic of)

    2011-04-28

    The effect of a coupling laser field on the entanglement of a three-level quantum system and its spontaneous emission is investigated via the reduced quantum entropy. We consider two schemes: the upper- and lower-level couplings. By calculating the degree of entanglement (DEM) for both systems, it is shown that the entanglement between the atom and its spontaneous emission can be controlled by the coupling laser field. This field, however, affects the entanglement differently in the two schemes; it is only the lower-level coupling scheme that shows a non-zero steady state DEM which can be controlled by the intensity and detuning of the coupling laser field.

  7. Research on the construction of three level customer service knowledge graph

    Science.gov (United States)

    Cheng, Shi; Shen, Jiajie; Shi, Quan; Cheng, Xianyi

    2017-09-01

    With the explosion of knowledge and information of the enterprise and the growing demand for intelligent knowledge management and application and improve business performance the knowledge expression and processing of the enterprise has become a hot topic. Aim at the problems of the electric marketing customer service knowledge map (customer service knowledge map) in building theory and method, electric marketing knowledge map of three levels of customer service was discussed, and realizing knowledge reasoning based on Neo4j, achieve good results in practical application.

  8. Rotation gate for a three-level superconducting quantum interference device qubit with resonant interaction

    International Nuclear Information System (INIS)

    Yang, C.-P.; Han Siyuan

    2006-01-01

    We show a way to realize an arbitrary rotation gate in a three-level superconducting quantum interference device (SQUID) qubit using resonant interaction. In this approach, the two logical states of the qubit are represented by the two lowest levels of the SQUID and a higher-energy intermediate level is utilized for the gate manipulation. By considering spontaneous decay from the intermediate level during the gate operation, we present a formula for calculating average fidelity over all possible initial states. Finally, based on realistic system parameters, we show that an arbitrary rotation gate can be achieved with a high fidelity in a SQUID

  9. Optimal control of population and coherence in three-level Λ systems

    International Nuclear Information System (INIS)

    Kumar, Praveen; Malinovskaya, Svetlana A; Malinovsky, Vladimir S

    2011-01-01

    Optimal control theory (OCT) implementations for an efficient population transfer and creation of maximum coherence in a three-level system are considered. We demonstrate that the half-stimulated Raman adiabatic passage scheme for creation of the maximum Raman coherence is the optimal solution according to the OCT. We also present a comparative study of several implementations of OCT applied to the complete population transfer and creation of the maximum coherence. Performance of the conjugate gradient method, the Zhu-Rabitz method and the Krotov method has been analysed.

  10. Two and Three-Phases Fractal Models Application in Soil Saturated Hydraulic Conductivity Estimation

    Directory of Open Access Journals (Sweden)

    ELNAZ Rezaei abajelu

    2017-03-01

    Full Text Available Introduction: Soil Hydraulic conductivity is considered as one of the most important hydraulic properties in water and solutionmovement in porous media. In recent years, variousmodels as pedo-transfer functions, fractal models and scaling technique are used to estimate the soil saturated hydraulic conductivity (Ks. Fractal models with two subset of two (solid and pore and three phases (solid, pore and soil fractal (PSF are used to estimate the fractal dimension of soil particles. The PSF represents a generalization of the solid and pore mass fractal models. The PSF characterizes both the solid and pore phases of the porous material. It also exhibits self-similarity to some degree, in the sense that where local structure seems to be similar to the whole structure.PSF models can estimate interface fractal dimension using soil pore size distribution data (PSD and soil moisture retention curve (SWRC. The main objective of this study was to evaluate different fractal models to estimate the Ksparameter. Materials and Methods: The Schaapetal data was used in this study. The complex consists of sixty soil samples. Soil texture, soil bulk density, soil saturated hydraulic conductivity and soil particle size distribution curve were measured by hydrometer method, undistributed soil sample, constant head method and wet sieve method, respectively for all soil samples.Soil water retention curve were determined by using pressure plates apparatus.The Ks parameter could be estimated by Ralws model as a function of fractal dimension by seven fractal models. Fractal models included Fuentes at al. (1996, Hunt and Gee (2002, Bird et al. (2000, Huang and Zhang (2005, Tyler and Wheatcraft (1990, Kutlu et al. (2008, Sepaskhah and Tafteh (2013.Therefore The Ks parameter can be estimated as a function of the DS (fractal dimension by seven fractal models (Table 2.Sensitivity analysis of Rawls model was assessed by making changes±10%, ±20% and±30%(in input parameters

  11. The influence of core materials and mix on the performance of a 100 kVA three phase transformer core

    Energy Technology Data Exchange (ETDEWEB)

    Snell, David E-mail: dave.snell@cogent-power.com; Coombs, Alan

    2003-01-01

    Various grades of grain-oriented electrical steel, and the effect of mixing domain refined and non-domain refined materials in the same three phase transformer core have been assessed using a developed computer-based test system. Ball unit domain refined material and non-domain refined material can be successfully mixed in the same core, without degrading performance.

  12. Bubble splitting under gas–liquid–liquid three-phase flow in a double T-junction microchannel

    NARCIS (Netherlands)

    Liu, Yanyan; Yue, Jun; Zhao, Shuainan; Yao, Chaoqun; Chen, Guangwen

    Gas–aqueous liquid–oil three-phase flow was generated in a microchannel with a double T-junction. Under the squeezing of the dispersed aqueous phase at the second T-junction (T2), the splitting of bubbles generated from the first T-junction (T1) was investigated. During the bubble splitting process,

  13. Proposal of a resonant controller for a three phase four wire grid-connected shunt hybrid filter

    DEFF Research Database (Denmark)

    Candela, J. I.; Rodriguez, P.; Luna, A.

    2009-01-01

    This paper present a three-phase four wire hybrid filter able to perform a selective cancellation of harmonic currents based on resonant controllers. As it will be shown in this work, this kind of control permits to enhance the bandwidth of the filter controller, without hindering the stability...

  14. Controller design and implementation of a three-phase Active Front End using SiC based MOSFETs

    DEFF Research Database (Denmark)

    Haase, Frerk; Kouchaki, Alireza; Nymand, Morten

    2015-01-01

    The design and implementation of a three phase Active Front End for power factor correction purposes using fast switching SiC based MOSFETs is presented. Possible applications are within the drives- and renewable energy sector. The controller is designed and implemented in the synchronous rotating...

  15. Single-stage three-phase AC to DC conversion with isolation and Bi-directional power flow

    NARCIS (Netherlands)

    Vermulst, B.J.D.; Duarte, J.L.; Wijnands, C.G.E.; Lomonova, E.A.

    2014-01-01

    An approach for three-phase AC to DC conversion is proposed, which consists of a single-stage while offering galvanic isolation, soft-switching, bi-directional power flow and a significant reduction of inductive and capacitive energy storage. Two elements enable this approach, namely a neutral

  16. A unified triangle carrier based PWM strategy for three-phase N-level diode clamped inverters

    DEFF Research Database (Denmark)

    Li, Kai; Xie, Chuan; Wei, Min

    2017-01-01

    The triangle carrier based pulse width modulation (TCB-PWM) can be functionally equivalent to space vector base PWM (SVB-PWM). For multi-level inverter, it is very difficult to realize the SVB-PWM because its vector space is very complex. In this paper, a unified TCB-PWM strategy for three-phase ...

  17. A control strategy for multi-functional converter to improve grid power quality

    DEFF Research Database (Denmark)

    Li, Fei; Wang, Xiongfei; Chen, Zhe

    2011-01-01

    The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi-funct......) for multi-functional converter is described. Simulation and hardware in the loop real time test results carried on a three-phase four-wire distributed generation system illustrate the effectiveness of the proposed control strategy.......The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi......-functional converter which can compensate reactive power, harmonic currents, unbalance, and neutral current simultaneously under distorted voltage conditions, besides the active power exchange. The capacity of the converter is taken into account. The proposed control strategy based on synchronous reference frame (SRF...

  18. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  19. Converting the reset

    NARCIS (Netherlands)

    J.K. Hoogland (Jiri); C.D.D. Neumann; D. Bloch

    2001-01-01

    textabstractWe give a simple algorithm to incorporate the effects of resets in convertible bond prices, without having to add an extra factor to take into account the value of the reset. Furthermore we show that the effect of a notice period, and additional make-whole features, can be treated in a

  20. Definition of Power Converters

    CERN Document Server

    Bordry, F

    2015-01-01

    The paper is intended to introduce power conversion principles and to define common terms in the domain. The concept s of sources and switches are defined and classified. From the basic laws of source interconnections, a generic method of power converter synthesis is presented. Some examples illustrate this systematic method. Finally, the commutation cell and soft commuta tion are introduced and discussedd.

  1. Thermoelectrode for thermoelectric converter

    International Nuclear Information System (INIS)

    Bodiul, Pavel; Bondarciuc, Nicolae; Ghitu, Dumitru; Nikolaeva, Albina; Konopko, Leonid; Turcan, Ana

    2008-01-01

    The invention relates to the electronic engneering and can be used for manufacturing of thermoelectrodes for thermoelectric converters. The thermoelectrode is made of semiconductor anisotropic material in the form of thread in glass insulation. At the same timer, the thread is made of stannum-doped tellurium in the ratio of 0.1...3 at.%.

  2. A three-level support method for smooth switching of the micro-grid operation model

    Science.gov (United States)

    Zong, Yuanyang; Gong, Dongliang; Zhang, Jianzhou; Liu, Bin; Wang, Yun

    2018-01-01

    Smooth switching of micro-grid between the grid-connected operation mode and off-grid operation mode is one of the key technologies to ensure it runs flexible and efficiently. The basic control strategy and the switching principle of micro-grid are analyzed in this paper. The reasons for the fluctuations of the voltage and the frequency in the switching process are analyzed from views of power balance and control strategy, and the operation mode switching strategy has been improved targeted. From the three aspects of controller’s current inner loop reference signal, voltage outer loop control strategy optimization and micro-grid energy balance management, a three-level security strategy for smooth switching of micro-grid operation mode is proposed. From the three aspects of controller’s current inner loop reference signal tracking, voltage outer loop control strategy optimization and micro-grid energy balance management, a three-level strategy for smooth switching of micro-grid operation mode is proposed. At last, it is proved by simulation that the proposed control strategy can make the switching process smooth and stable, the fluctuation problem of the voltage and frequency has been effectively improved.

  3. Coherent population dynamics of a three-level atom in spacetime

    International Nuclear Information System (INIS)

    Netz, R.; Sauerbrey, R.; Feurer, T.; Roberts, G.

    2002-01-01

    This work explores temporal and spatial aspects of coherent population transfer in a three-level atom through a synergic combination of experimental measurements and theoretical calculations. Experimental measurements exploit the broad bandwidth of a femtosecond laser pulse to initiate simultaneous excitation of the 5p 2 P 1/2 2 S 1/2 and 5p 2 P 3/2 2 S 1/2 components of the doublet line of atomic rubidium. By adjusting positive or negative frequency sweeps the pump pulse favors either one of the two transitions and eventually even decouples the two excited states. The population of the excited spin-orbit levels is monitored in real time by stimulated emission probing under conditions of different intensity, chirp, and pulse width of the driving field, giving detailed information on the coupling between the three levels and their interactions with the driving and probe fields at different points in spacetime. Both pump and probe pulses are carefully characterized after the interaction region by frequency-resolved optical gating. In order to interpret and understand the experimental results it is essential to consider the close relationship between pulse propagation and time evolution of the atomic system via the coupled Maxwell-Bloch equations. This analysis highlights the importance of spatial propagation of the light fields, as well as their temporal dependence, in understanding the dynamical population evolution, and quantitatively reproduces all aspects of the experimental measurements

  4. Uhrig dynamical control of a three-level system via non-Markovian quantum state diffusion

    International Nuclear Information System (INIS)

    Shu, Wenchong; Zhao, Xinyu; Jing, Jun; Yu, Ting; Wu, Lian-Ao

    2013-01-01

    In this paper, we use the quantum state diffusion (QSD) equation to implement the Uhrig dynamical decoupling to a three-level quantum system coupled to a non-Markovian reservoir comprising of infinite numbers of degrees of freedom. For this purpose, we first reformulate the non-Markovian QSD to incorporate the effect of the external control fields. With this stochastic QSD approach, we demonstrate that an unknown state of the three-level quantum system can be universally protected against both coloured phase and amplitude noises when the control-pulse sequences and control operators are properly designed. The advantage of using non-Markovian QSD equations is that the control dynamics of open quantum systems can be treated exactly without using Trotter product formula and be efficiently simulated even when the environment is comprised of infinite numbers of degrees of freedom. We also show how the control efficacy depends on the environment memory time and the designed time points of applied control pulses. (paper)

  5. The Convertible Arbitrage Strategy Analyzed

    NARCIS (Netherlands)

    Loncarski, I.; Ter Horst, J.R.; Veld, C.H.

    2006-01-01

    This paper analyzes convertible bond arbitrage on the Canadian market for the period 1998 to 2004.Convertible bond arbitrage is the combination of a long position in convertible bonds and a short position in the underlying stocks. Convertible arbitrage has been one of the most successful strategies

  6. Mitigation of Power Quality Issues Due to High Penetration of Renewable Energy Sources in Electric Grid Systems Using Three-Phase APF/STATCOM Technologies: A Review

    Directory of Open Access Journals (Sweden)

    Wajahat Ullah Khan Tareen

    2018-06-01

    Full Text Available This study summarizes an analytical review on the comparison of three-phase static compensator (STATCOM and active power filter (APF inverter topologies and their control schemes using industrial standards and advanced high-power configurations. Transformerless and reduced switch count topologies are the leading technologies in power electronics that aim to reduce system cost and offer the additional benefits of small volumetric size, lightweight and compact structure, and high reliability. A detailed comparison of the topologies, control strategies and implementation structures of grid-connected high-power converters is presented. However, reducing the number of power semiconductor devices, sensors, and control circuits requires complex control strategies. This study focuses on different topological devices, namely, passive filters, shunt and hybrid filters, and STATCOMs, which are typically used for power quality improvement. Additionally, appropriate control schemes, such as sinusoidal pulse width modulation (SPWM and space vector PWM techniques, are selected. According to recent developments in shunt APF/STATCOM inverters, simulation and experimental results prove the effectiveness of APF/STATCOM systems for harmonic mitigation based on the defined limit in IEEE-519.

  7. Design and implementation of high performance direct power control of three-phase PWM rectifier, via fuzzy and PI controller for output voltage regulation

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Krim, Fateh; Gaubert, Jean-Paul

    2009-01-01

    This paper proposes direct power control (DPC) for three-phase PWM rectifiers using a new switching table, without line voltage sensors. The instantaneous active and reactive powers, directly controlled by selecting the optimum state of the converter, are used as the PWM control variables instead of the phase line currents being used. The main goal of the control system is to maintain the dc-bus voltage at the required level, while input currents drawn from the power supply should be sinusoidal and in phase with respective phase voltages to satisfy the unity power factor (UPF) operation. Conventional PI and a designed fuzzy logic-based controller, in the dc-bus voltage control loop, have been used to provide active power command. A dSPACE based experimental system was developed to verify the validity of the proposed DPC. The steady-state, and dynamic results illustrating the operation and performance of the proposed control scheme are presented. As a result, it was confirmed that the novel DPC is much better than the classical one. Line currents very close to sinusoidal waveforms (THD < 2%) and good regulation of dc-bus voltage are achieved using PI or fuzzy controller. Moreover, fuzzy logic controller gives excellent performance in transient state, a good rejection of impact load disturbance, and a good robustness

  8. An Active Power Filter Based on a Three-Level Inverter and 3D-SVPWM for Selective Harmonic and Reactive Compensation

    Directory of Open Access Journals (Sweden)

    José Luis Monroy-Morales

    2017-03-01

    Full Text Available Active Power Filters (APFs have been used for reducing waveform distortion and improving power quality. However, this function can be improved by means of a selective harmonic compensation. Since an APF has rating restrictions, it is convenient to have the option of selecting an individual or a set of particular harmonics in order to compensate and apply the total APF capabilities to eliminate these harmonics, in particular those with a greater impact on the Total Harmonic Distortion (THD. This paper presents the development of a new APF prototype based on a three-phase three-level Neutral Point Clamped (NPC inverter with selective harmonic compensation capabilities and reactive power compensation. The selective harmonic compensation approach uses several Synchronous Rotating Frames (SRF, to detect and control individual or a set of harmonics using d and q variables. The APF includes a Three-Dimensional Space Vector Modulator (3D-SVPWM in order to generate the compensation currents. Because of its multilevel topology, the proposed active power filter can be used in diverse power quality applications at sub-transmission and distribution voltage levels. Simulation and experimental results are shown to validate the proposed solution and assess the prototype performance in different scenarios.

  9. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago

    2012-01-01

    clamping scheme is the ML clamping cell, which is composed of a pair of dc sources associated with one single-pole/triple-throw type of switch arrangement. The number of series-connected ML-clamping cells will set the number of levels of the synthesized waveform. By depending on the MCU arrangements......, different converter configurations can be derived, namely, the common clamping and the modular types. Both approaches can be accomplished by employing classical three-level neutral-point-clamped (NPC) technology. Thus, the overall structure of the resultant converter is kept simple, wherein the number...

  10. Three-level multilevel growth models for nested change data: a guide for group treatment researchers.

    Science.gov (United States)

    Tasca, Giorgio A; Illing, Vanessa; Joyce, Anthony S; Ogrodniczuk, John S

    2009-07-01

    Researchers have known for years about the negative impact on Type I error rates caused by dependencies in hierarchically nested and longitudinal data. Despite this, group treatment researchers do not consistently use methods such as multilevel models (MLMs) to assess dependence and appropriately analyse their nested data. The goals of this study are to review some of the study design issues with regard to hierarchically nested and longitudinal data, discuss MLMs for assessing and handling dependence in data, and present a guide for developing a three-level growth MLM that is appropriate for group treatment data, design, and research questions. The authors present an example from group treatment research to illustrate these issues and methods.

  11. Atomic mirrors for a Λ-type three-level atom

    International Nuclear Information System (INIS)

    Felemban, Nuha; Aldossary, Omar M; Lembessis, Vassilis E

    2014-01-01

    We propose atom mirror schemes for a three-level atom of Λ-type interacting with two evanescent fields, which are generated as a result of the total internal reflection of two coherent Gaussian laser beams at the interface of a dielectric prism with vacuum. The forces acting on the atom are derived by means of optical Bloch equations, based on the atomic density matrix elements. The theory is illustrated by setting up the equations of motion for 23 Na atom. Two types of excited schemes are examined, namely the cases in which the evanescent fields have polarization types of σ + −σ − and σ + −π. The equations are solved numerically and we get results for atomic trajectories for different parameters. The performance of the mirror for the two types of polarization schemes is quantified and discussed. The possibility of reflecting atoms at pre-determined directions is also discussed. (paper)

  12. Dual Z-Source Inverter With Three-Level Reduced Common-Mode Switching

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2007-01-01

    This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck......-boost power conversion to be performed over a wide modulation range, with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye-or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter....... Modulationwise, the dual inverter can be controlled using a carefully designed carrier-based pulsewidth-modulation (PWM) scheme that will always ensure balanced voltage boosting of the Z-source network while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays...

  13. Subwavelength atom localization via quantum coherence in a three-level atomic system

    Energy Technology Data Exchange (ETDEWEB)

    Ghafoor, Fazal [Centre for Quantum Physics, COMSATS Institute of Information Technology, Islamabad (Pakistan)

    2011-12-15

    We propose a three-level atomic system where quantum coherence is generated by a classical standing-wave field coupled to the two upper excited decaying levels. Quantum coherence results in cancellation of the spontaneously emitted spectral lines depending on the choice of the phase of the standing wave. We exploit this phenomenon for precision measurement of the atomic position in the standing wave. Measurement of the conditional position probability distribution shows one to eight peaks per unit wavelength of the standing wave. Only one controllable parameter, that is, the phase of the driving standing wave, is enough to control these atomic positions. Along with the other results, the result of obtaining a single peak is remarkable as it enhances the efficiency of our system by a factor of 8.

  14. Subwavelength atom localization via quantum coherence in a three-level atomic system

    International Nuclear Information System (INIS)

    Ghafoor, Fazal

    2011-01-01

    We propose a three-level atomic system where quantum coherence is generated by a classical standing-wave field coupled to the two upper excited decaying levels. Quantum coherence results in cancellation of the spontaneously emitted spectral lines depending on the choice of the phase of the standing wave. We exploit this phenomenon for precision measurement of the atomic position in the standing wave. Measurement of the conditional position probability distribution shows one to eight peaks per unit wavelength of the standing wave. Only one controllable parameter, that is, the phase of the driving standing wave, is enough to control these atomic positions. Along with the other results, the result of obtaining a single peak is remarkable as it enhances the efficiency of our system by a factor of 8.

  15. Quantum coherence dynamics of a three-level atom in a two-mode field

    International Nuclear Information System (INIS)

    Solovarov, N. K.

    2008-01-01

    The correlated dynamics of a three-level atom resonantly coupled to an electromagnetic cavity field is calculated (Λ, V, and L models). A diagrammatic representation of quantum dynamics is proposed for these models. As an example, Λ-atom dynamics is examined to demonstrate how the use of conventional von Neumann's reduction leads to internal decoherence (disentanglement-induced decoherence) and to the absence of atomic coherence under multiphoton excitation. The predicted absence of atomic coherence is inconsistent with characteristics of an experimentally observed atom-photon entangled state. It is shown that the correlated reduction of a composite quantum system proposed in [18] qualitatively predicts the occurrence and evolution of atomic coherence under multiphoton excitation if a seed coherence is introduced into any subsystem (the atom or a cavity mode)

  16. Optical bistability in the oscillation of an inhomogeneously broadened quasi-three-level laser

    International Nuclear Information System (INIS)

    Liu, Junhai; Tian, Xueping

    2013-01-01

    A theoretical modeling analysis is presented to study the optical bistability exhibited in the oscillation of an inhomogeneously broadened quasi-three-level laser. All the major characteristics of optical bistability depend on two normalized parameters, f and x a , which are defined by f = I sat,a /I sat,m and x a = 2α a0 p a /δ and are related to measurable properties of the laser medium. In comparison with the case of a homogeneously broadened laser, the essential condition for the occurrence of such bistability, f a /(x a + 1), turns out to be the same, whereas the intensities at the up- and down-thresholds are substantially increased and the bistability range is reduced. (paper)

  17. Three-dimensional atom localization via electromagnetically induced transparency in a three-level atomic system.

    Science.gov (United States)

    Wang, Zhiping; Cao, Dewei; Yu, Benli

    2016-05-01

    We present a new scheme for three-dimensional (3D) atom localization in a three-level atomic system via measuring the absorption of a weak probe field. Owing to the space-dependent atom-field interaction, the position probability distribution of the atom can be directly determined by measuring the probe absorption. It is found that, by properly varying the parameters of the system, the probability of finding the atom in 3D space can be almost 100%. Our scheme opens a promising way to achieve high-precision and high-efficiency 3D atom localization, which provides some potential applications in laser cooling or atom nano-lithography via atom localization.

  18. Three-level approach to quality programs for research, development and production

    International Nuclear Information System (INIS)

    Davis, A.H.; Bussolini, P.L.; Geoffrion, R.R.

    1986-01-01

    A primary mission of the Los Alamos National Laboratory is to develop nuclear weapons systems for the Department of Defense. The activities included in this effort cover a broad spectrum, ranging from pure research to routine production. In order to provide a workable framework for a comprehensive quality assurance program for these varied activities, we have proposed a three-level structure of quality plans, corresponding to a rough classification of the weapons work into three general categories. These categories are: (1) research into materials and processes, and preliminary development; (2) design, development, and fabrication of prototype components; (3) routine production, analysis, or refinement activities. The first category requires a quality program to assure the validity, reliability, and retrievability of the information developed; this is accomplished by a conscientious application of what is generally recognized as good laboratory practice. The second category requires in addition a strong emphasis on design review and inspection. For the third category, a comprehensive quality program is appropriate

  19. EIT enhanced self-Kerr nonlinearity in the three-level lambda system under Doppler broadening

    International Nuclear Information System (INIS)

    Doai, Le Van; Khoa, Dinh Xuan; Bang, Nguyen Huy

    2015-01-01

    Using density-matrix theory, an analytical expression of the self-Kerr nonlinear coefficient of a three-level lambda EIT medium for a weak probe light is derived. Influences of the coupling light and Doppler broadening on the self-Kerr coefficient are investigated and compared to experimental observation with a good agreement. The self-Kerr nonlinearity of the medium is modified and greatly enhanced in the spectral region of EIT window. Furthermore, sign, slope, and magnitude of the self-Kerr coefficient can be controlled with frequency and intensity of the coupling light and temperature of the medium. In particular, for a given set of fixed values of the parameter coupling and probe lights, it is possible to choose an optimized temperature with which to obtain the largest magnitude of the self-Kerr coefficient. Such a controllable Kerr nonlinearity can find interesting applications in optoelectronic devices working with low-light intensity at various temperature conditions. (paper)

  20. EIT enhanced self-Kerr nonlinearity in the three-level lambda system under Doppler broadening

    International Nuclear Information System (INIS)

    Dinh Xuan Khoa; Le Van Doai; Pham Van Trong; Tran Manh Cuong; Vu Ngoc Sau; Nguyen Huy Bang; Le Nguyen Mai Anh

    2014-01-01

    Using density-matrix theory, an analytical expression of the self-Kerr nonlinear coefficient of a three-level lambda EIT medium for a weak probe light is derived. Influences of the coupling light and Doppler broadening on the self-Kerr coefficient are investigated and compared to experimental observation with a good agreement. The self-Kerr nonlinearity of the medium is modified and greatly enhanced in the spectral region of EIT window. Furthermore, sign, slope, and magnitude of the self-Kerr coefficient can be controlled with frequency and intensity of the coupling light and temperature of the medium. Specially, for a given set of fixed values of the parameters of coupling and probe lights, it could be able to choose an optimized temperature to have largest magnitude of the self-Kerr coefficient. Such controllable Kerr nonlinearity can find interesting applications in optoelectronic devices working with low-light intensity at various temperature conditions. (author)